HomeMy WebLinkAboutPermit PG07-218 - GRENSTEAD RESIDENCEGRENSTEAD RESIDENCE 4007 S 117 PL PGO7-218 Parcel No.: 7340600102 Address: Suite No: 4007 S 117 PL TUKW Tenant: Name: GRENSTEAD RESIDENCE Address: 4007 S 117 PL , TUKWILA WA Contact Person: Name: STARLA MUIR Address: 6921 51 AV S , SEATTLE WA DESCRIPTION OF WORK: WATER HEATER CHANGEOUT Value of Plumbing /Gas Piping: $700.00 Fees Collected: $88.00 doc: UPC-10 /06 Cityf Tukwila Owner: Name: GRENSTEAD TRACEY D Address: 4007 S 117TH PL , SEATTLE WA Contractor: Name: T P J INC Address: 351 UNION AVE NE , RENTON WA Contractor License No: TPJIN * *981NR Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 941 -3791 Phone: (425)228 -3204 Expiration Date: 08/19/2008 PG07 -218 08/24/2007 02/20/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 O Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 O Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping O Gas piping outlets (0 -5) 0 O Gas piping outlets (6 +) 0 PG07 -218 Printed: 08-24 -2007 Permit Center Authorized Signature: I hereby certify that I have read an ex ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compli th, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Date: l J I of Print Name: l 4 f / 41 t' 1 6 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG07 -218 Issue Date: 08/24/2007 Permit Expires On: 02/20/2008 Date: 0512 PG07 -218 Printed: 08-24 -2007 Parcel No.: 7340600102 Address: Suite No: Tenant: 4007 S 117 PL TUKW GRENSTEAD RESIDENCE 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -218 ISSUED 08/24/2007 08/24/2007 PG07 -218 Printed: 08 -24 -2007 'spiv City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: 14a, , ' L 1 ' Date: WQ9 /Di Print Name: doc: Cond -10/06 ✓lC )1'1c) PG07 -218 Printed: 08 -24 -2007 Company Name: Mailing Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mailing Address: o5 0 gyjL Contact Person: E -Mail Address: Contractor Registration Number: Plumbing /Gas Permit No. Project No . ro PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION J I (� ` King Co Assessor's Tax No.: 1 C./1 O ( ~ Site Address: "1 e)( l (i 1 i" l . 3 \_7 L Ii\ I VI Suite Number: Floor: Tenant Name: T - (y, z.. flit Q New Tenant: 0 .... Yes 41 ..No Property Owners Name: �Q , C` l 1 Di r aQ ,�'1 ,\kQ a. t SrIS * 9 ?/A/C Q:\ApplicationssFonns- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4-2006 bb cnQ City ice use only) State CONTACT PERSON —Who do we contact when your permit is ready to be issued Name: . 2A j Y ' l U 1 J2 (1. Day Telephone: �, 0) y I — 3� 9 Mailing Address: L5) 1 — 5 � ,� AND (`g pp __ r / city E -Mail Address: k I i'icD O_ ( C _ O Y)\ Fax Number: State Zip PLUMBING / GAS PIPING CONTRACTOR INFORMATIO city Day Telephone: Fax Number: Expiration Date: State ARCHITECT OF RECORD -- All plans must b wet s tamped by :Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: State ENGINEER OF RECORD — All plans must be wet stamped by Engineer,of Recor Company Name: Mailing Address: city Day Telephone: Fax Number: State Zip Zip Zip Zip Page 1 of 2 Fixture Type: -. Qty : , Fixture Type: Qty > Fixture Type - :Qty: Fixture Type: , Q � :. Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks , Dental unit, cuspidor Shower, single head trap Urinals ,Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) _ Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): K BUILDING OWNS OR AUTHORIZED AGENT: Signature: ' (Llj'.. Print Name: Mailing Address: Date Application Accepted: (24 01- Q:\Applications\Fonns- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4 -2006 bh 016,1-6, 1-drTh Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Tele• hone: Staff Initials: Date Application Expires: Parcel No.: 7340600102 Address: 4007 S 117 PL TUKW Suite No: Applicant: GRENSTEAD RESIDENCE Receipt No.: R07 - 01792 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: TOTAL HOME IMPROVEMENT, INC. TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLUMBING - RES RECEIPT Initials: JEM Payment Date: 08/24/2007 08:57 AM User ID: 1165 Balance: $0.00 Amount Payment Check 4302 88.00 Account Code Current Pmts 000/322.100 88.00 Total: $88.00 Permit Number: PG07 -218 Status: PENDING Applied Date: 08/24/2007 Issue Date: Payment Amount: $88.00 2030 08/24 8710 TOTAL 80.00 doc: Receipt -06 Printed: 08 -24 -2007 Project: 6`-e V 7 '9( °s - Type of Inspection: / / V ■ Address: Date Called: Special Instructions: Date Waned: -0 p.m. Requester: Phone No: / 7q / INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 70 COMMENTS: 'Inspect 1 Date 2 0:1 0. 67 Approved per applicable codes. Corrections required prior to approval. k El $58.00 REINSPECTIO *EE REQUIRED. Prior to inspection. fee must be paid at 6300 Southce er Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: J / 7 Zw PERMIT NO. '� „•�y:,}..x "'afa�,'...J�. Project: 6-rae7 ?O r- Type of Inspectin / 6) `c--/...v+ , 17Leo E. Address: '7/007 //7 'PL. Date Called: Special Instructions: Date Wanted: ,--,27-O n p.m. Requester: Phonelg ,...,?z/7 _ 7 77/ ,INSPECTION RECORD Retain a copy with permit INSPECTIOI NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter-Blvd., #100, Tukwila, WA 98188 (206)431-36 Approved per applicable codes. COMMENTS: Inspecto )21 Corrections required prior to approval. T e - b -- I ("-r /-0 , ce-77.1 4 h /4) 7/7 V'? .1-1/7.A-to 1.7 car I Date $58.00 REINSPECTIOItEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: License Information License TPJIN * *981NR Licensee Name T P J INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602212259 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 351 UNION AVE NE Address 2 City RENTON County KING State WA Zip 98059 Phone 4252283204 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/19/2002 Expiration Date 8/19/2008 Suspend Date Separation Date Parent Company Previous License PLUMB ** 132CB Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PALMER, DONALD L PRESIDENT 08/19/2002 PALMER, CANDANCE L VICE PRESIDENT 08/19/2002 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Until Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TPJIN * * 981NR 08/24/2007