Loading...
HomeMy WebLinkAboutPermit PG07-261 - WESTFIELD SOUTHCENTER MALL - GILLY HICKSGILLY HICKS 457 SOUTHCENTER MALL PGO7-26 1 Parcel No.: 6364200010 Address: Suite No: DESCRIPTION OF WORK: PLUMBING FOR NEW TI Value of Plumbing /Gas Piping: Fees Collected: doc: UPC-10 /06 City..if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 457 SOUTHCENTER MALL TUKW Tenant: Name: GILLY HICKS Address: 457 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: ROB HUMPHREY Address: 833 SE MAIN ST #242 , PORTLAND OR Contractor: Name: HANLIN RAINALDI CONSTRUCTION Address: 6610 SINGLETREE DR , COLUMBUS OH Contractor License No: HANLIRC962NQ $11,000.00 $185.00 Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 320 -5030 Phone: 614 - 436 -4204 Expiration Date: 07/17/2009 PG07 -261 01/30/2008 07/28/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 2 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 1 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 PG07 -261 Printed: 01 -30 -2008 Permit Center Authorized Signature: Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 77004er 7,4vo, 4rs1 Y Permit Number: PGO7 -261 Issue Date: 01/30/2008 Permit Expires On: 07/28/2008 Date: 1 - 30 — VU I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo y„ e of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date: / -30 -0 f This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG07 -261 Printed: 01 -30 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 457 SOUTHCENTER MALL TUKW GILLY HICKS 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or art approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -261 ISSUED 10/04/2007 01/30/2008 PG07 -261 Printed: 01 -30 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the perform�ryce of work. Signature: Print Name: oZele.r 2460.vac r doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: / -20--42 g PG07 -261 Printed: 01 -30 -2008 Site Address: q ot)th CFNj E1L /}LL Tenant Name: COO c. zrr S Property Owners Name: l✓ ESr ri Mailing Address: t tool L4.) t_5(4 k 'bv■.16 (- f isut CONI;ACT PERS1 rmrt is ready to be Name: �-03 F-1 vd g Y 5-5r 6 tPC�$M fis Mailing Address: 533 Se MA iN S r 1- t- 5*) Oa- 9 7 ZIP State Zip E -Mail Address: GENE RAL CO TRACTOR INFORMA t (Cont Jnforination for Mechanical (pg 4) for Plumbing and Gas P iping Company Name: To Mailing Address: City Day Telephone: Fax Number. Contact Person: E -Mail Address: Contractor Registration Number: Arc RECORD All Plans must Company Name: Mailing Address: Contact Person: CA-TA `'( 1 t-ethet-J 0 E E -Mail Address: CITY OF TUKWII.A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwatukwila.wa.us j2.1 Q (/-Sre P.- Fc•Nv% t r J . ca arm Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Mao D(SCovfr1 Company Name: tf V Pha I o e?-S Mailing Address: Contact Person: - 12-D Y. ToN.Nf Do-) ) C M( t> tb�V/■-'t -tFa - E -Mail Address: Q:\ApplieationsWonns- Applications On Cinc3-2006 - Permit Application.doc Revised: 9 -2006 bh City City King Co Assessor's Tax No.: Suite Number: IV O) New Tenant: Floor: .... Yes EJ ..No C A. , State U ZS tip - Day Telephone: 5 ` 3 It " .s O 3 Fax Number: ;'' 3 2 c fl - - 1 -40 3 0 city Day Telephone: Fax Number: State Expiration Date: U8t-itJ 1 064- ci3o 17 Tap City Day Telephone: to ( q 631 7 O- Fax Number: (of '{ 3 7 7 7/ State Zip Y301-, Zip (cs y 7 oot,. (0s1 )777 Page 1 of 6 Valuation of Project (contractor's bid price): $ I g6 1 000 Existing Building Valuation: $ ---- Scope of Work (please provide detailed information): H �w T�NA'C M el -t3JE 1 — T I 5:` I rI r -L a 1 � � new rack storage? ❑.... Yes 92:34. No If yes, a separate permit and plan s •mittal will be required. Bas in Squ re,Footage in DIVISION: ory dwelling, (sq ft): (B building footprint . ea of the foundation of all structures, plus any decks over 18 t ches and overhangs greater than 18 inches) vide the following: Floor area of principal dwelling: Floor area of accessory dwelling: Will there be PLANNING Single family *For an Access Lot Area *Provide docum Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: F p Sprinklers V) Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If . "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications Pones- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh on that shows that the principal owner lives in one of the dwellings as i is or Compact: her primary residence. Handicap: o If `yes ", explain: Page 2 of 6 Fixture' Type ; :.', .' ' Qt)'_ , Fix"ture Type' Qn' ; Fixture Type:' ;: Fixture Type I 'Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain a Sinks #1 Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory ^ d� Water Closet Di Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBYNG AND GA,S PIPIN RMIT INFORMATION 206 -431 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: 7o ID Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ ) � 0 00 Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): l`J E t (. 1 ' Building Use (per Int'l Building Code): .400 acr Occupancy (per Int'l Building Code): Utility Purveyor: Water: Q: iApplicatio Forma- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: NF ) Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGE Signature: Print Name: Mailing Address: Date Application Expires: tyq Date Application Accepted: k- Q:\AppIicationsPornis-AppIication On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date: (D 13 /07 Day Telephone: 5 " 3 0 z y z ?rug dc, '724/ City State Zip Staff Initials: Page 6 of 6 Parcel No.: 6364200010 Permit Number: PGO7 -261 Address: 457 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/04/2007 Applicant: GILLY HICKS Issue Date: Receipt No.: R08 -00259 Initials: WER Payment Date: 01/30/2008 08:51 AM User ID: 1655 Balance: $0.00 Payee: HANLIN RAINALDI CONSTRUCTION TRANSACTION LIST: Type Method Description Amount doe: Receiot -06 Payment Check 81784 148.00 ACCOUNT ITEM LIST: Description PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 148.00 Total: $148.00 Payment Amount: $148.00 7862 01/30 9710 TOTAL 7146,50 Printed: 01 -30 -2008 Doc: RECSETS -06 RECEIPT NO: R07 -02170 Initials: JEM User ID: 1165 SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payee: PRECISION PERMIT SERVICE SET RECEIPT D07 -381 3,707.80 EL07 -562 196.80 M07 -211 225.96 PG07 -261 37.00 TOTAL: 4,167.56 Payment Date: 10/04/2007 Total Payment: 4,167.56 SET ID: S000000871 SET NAME: Trap set/Initialized Activities TRANSACTION LIST: Type Method Description Amount Payment Check 5007 4,167.56 TOTAL: 4,167.56 ACCOUNT ITEM UST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000.345.832.00.0 196.80 000/345.830 3,970.76 TOTAL: 4,167.56 IOTA! Project: ,... t el K 5 of Inspection: 1 1k I Address: Date Called: Special Instructions: Date Wanted: 7- 2 7 - u 6 a.m. _., p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit ; 607 2/4 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION M -' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: PP 1' i4 Cam. � fI INS Inspector Da ri $6 0 REINSPECTION FEE1REQUIRED. Prior to inspection, fee must be pa v at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: 5toy, l✓S./ 1. k TO 4.4/ Address: 145 114 No > to --..,n' Hi... h-, hat f9 He -r „.% f- Date Called: Special Instructions: 1 Flit— .7 /LN ij e'lrl - T j4-`-” `P pV <,! 1.7 /� C- f f T e" 41 4r0v� l'.a/Ir F air , Requester: / Phone No: 4. ill 341 X2 I Project: G- !iris Type of Inspection: flkiY, E Address: 145 114 Date Called: Special Instructions: ° Date Wanted: I r a.m. Requester: / Phone No: 4. ill 341 X2 I y Pb 07-261 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12— 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. ® Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (inspector: !Receipt No.: 'Date: (Date: 2 — / 3, �� Project: Type of Inspection: Ad d_ rgss : 7.- 3P / / '"r /1/A Date Palled. Special Instructions: Date Wanted: _3- 2.4 D 4 _ """, Requester: , Phone No: INSPECTION RECORD Retain a copy with permit IN ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: o)fik h,4 - Q ! -/;/ 4-4 $ s b0 REINSPECTION FEE REQ IRED. Prior to inspection, fee must be at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. J Rece pt No.: 'Date: roved per applicable codes. Corrections required prior to approval. F.. Project- Type o spection: Address: V.5 7 S6rf '�-A, / Date le l ? / . Special Instructions: Date Wanted: � % t95 -INS - 6507 . . Requester: Phone No: INSPECTION RECORD !� etain a copy with permit �66 222 INSPE ION NO. pY p PERMIT NO. CITY OF TUKWILA BUILDING DIVISION i 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 1 -,04 i /6k/.e —,V9/4" / /w e .1 / �i�� / I� ?� /'P // /e40 /0 k/v - -/0 pn /4/ Inspector:/ f' jet rate:7 f A ti e $ b0 REINSPECTION FEE REQ IRED. 'or to inspection, fee must be d at 6300 Southcenter Blvd., uite O. Call the schedule reinspection. 'Receipt No.: 'Date: Proj Coi4 / C Type of In pection: ie)/, k id , /C \ Address: 1 /5 - 7 -sa> / / Fti / -- 11hA Date Called: /7 Special Instructions: Date Wanted: // c /2 elo t p.m. Requester: Phone No: 53 -1 /v s - 2Z6 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. COMMENTS: ,C.vt° 4(. (Date El 0 REINSPECTION FE REQUIRE Prior to inspection, fee must be 9 d at 6300 Southcenter Blvd., Suit 100. Call the schedule reinspection. 'Receipt No.: (Date: INSPECTION RECORD Retain a copy with permit /EGG 7-26/ PERMIT NO. (206)431 -360 Corrections required prior to approval. ACTIVITY NUMBER: PG07 -261 DATE: 10 -04 -07 PROJECT NAME: I frjf6 SITE ADDRESS: 491 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: I Bu'ldin: Division Fire Prevention Pt6 / Works n I 1 0 _ 5\,03 Structural � /l'1 I KIJ� DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete ❑ Planning Division Structural Review Required ❑ Permit Coordinator ❑ DUE DATE: 10-09-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 11-06-07 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HANLIRC962NQ Licensee Name HANLIN RAINALDI CONSTRUCTION Licensee Type CONSTRUCTION CONTRACTOR UBI 602419302 Ind. Ins. Account Id TREASURER Business Type CORPORATION Address 1 6610 SINGLETREE DR Address 2 City COLUMBUS County OUT OF STATE State OH Zip 43229 Phone 6144364204 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/18/2004 Expiration Date 7/17/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date DOUGLASS, GRANT L PRESIDENT 08/18/2004 Bond Amount HANLIN, MICHAEL 0 TREASURER 08/18/2004 RAINALDI, EDWARD M VICE PRESIDENT 08/18/2004 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Look Up a Contractor, Electric' -n or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 2 httnc• / /fnrtresc wa onv/lni/hhin /nrinter acnx9T.i enge= HANT.TR(.967.N() 01 /10/700R v, R ` 0 � � -- }` LOCATE G SHUT -OFF BEHIND r s y f ACCESS PANT =I..� k Q 5 i : �., "� ., �, f ,. Y d 4 ' ....... ... �':= ` `: i f F: z,, . ..," ; :., > �A, = T om .. � , � � �R d �,. • ° ' °' " ° , . _ s.,- • n ; _ s ,. „ z y al�uY. r. '.:r.Sw... , s .. r , 5 J n .r 1 CODED NOTES: NTCEPT 5 r ' 4 � - GAS NOTES: FIRE PLACE PLUMBING CONTRACTOR TO CONNECT NEW GAS LINE TO VENTLE55 GAS FIRE LOG. INSTALL FER MANUFACTURER'S SPECIFICATIONS. CONTRACTOR TO PROVIDE ACCESS PANEL SHOWN ON SHEET A9.313) AND LOCATE GAS SHUTOFF VALVE AND MILIVOLT SWITCH BEHIND WALL ON SIDE OF FIREPLACE, AS INDICATED. 2® PLUMBING CONTRACTOR SHALL EXTEND A NEW GAS LINE FROM EXISTING GAS PROVIDE REGULATOR AND VALVES. CONTRACTOR SHALL VERIFY EXISTING SYSTEM PRESSURE AND SIZE NEW LINES AT .3" W.C. PRESSURE DROP. REFER TO MECWANICAL SPECIFICATIONS FOR GAS PIPING INSTALLATION REQUIREMENTS. ® EXISTING GAS STUB AND SHUT -OFF. FIELD VERIFY EXACT LOCATION AND PRESSURE TO 81D. 0 ALL WATER LINES, VENT LINES, DRAIN LINES, SPRINKLER LINES, ETC. SHALL BE OFFSFT BELOW PLATFORM AND CONCEALED IN WALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETC. TI- IROUGH STORAGE SPACE ABOVE PLATFORM OR ABOVE ELECTRICAL EQUIPMENT. 5 CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE. FIELD VERIFY EXACT LOCATION AND DIRECTION OF FLOW OF LANDLORD'S MAIN PRIOR TO BID. CO INSTALL CLEAN OUT, ORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MANAGER. TENANT'S TO STACK DIAGRAM OR MORE INFORMATION. FIELD VERIFY EXACT LOCATION PRIOR TO BID. ® CONNECT NEW GOLD WATER LINE INTO LANDLORD'S EXISTING COLD WATER TA CONSTRUCTION MANAGER IF TAP 5 LER SIZE IS SMALLER THAN SHOWN ON RISER DIAGRAM. FIELD VERIFY EXACT LOCATION OF TAP. V FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING A5 SHOWN ON THE WATER RISER DIAGRAM. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PLUMBING PRODUCTS ARE ACCEPTABLE. q ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE O FIXTURE. REFER TO PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. 10 RUN 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR TRAP PRIMER TO BE IN AN ACCESSIBLE LOCATION. INSTALL PER MANUFACTURER'S R EDO MMENDA N TID s. 11 PROVIDE SHUT -OFF VALVE, ETC. ALL IN ACCORDANCE WITH LANDLORD'S CRITERIA. A PRESSURE REDUCING VALVE WHEN INCOMING WATER PRESSURE IS GREATER THAN 60 PSI. ALL INSTALLATIONS AND CONNECTIONS SHALL BE IN ACCORDANCE WITH THE / CODES, LOCAL AUTHORITY'S REQUIREMENTS AND LANDLORD'S CRITERIA. y �`� 25'6 M1344 �Y1t ...s. ,:..�1 - _ .. . 4 y - - " - CW - 1 } i 1 1 ° � _.______. = .. -. .1 _ `` - 11® 1 - , x_" .. -,... � 4 �' v� w • ' . -�f .0 E« ,..,, � _ � a"wi ,.. x�:a- ..M.'�i�e,•. �: -,: , -, "'4^ .., n,.u.nw. , -.. +. ....... o-. s W . .. ro .w u . s .. .- tL^i5:, R 'S -.i.. _ .,^Y".....Q. - 1 4 a -.,_ _- .,M• -. , . -„ i�r ` '. . -. - K. e r.i �n �w ' a�' �; .0 7 .n .. .... ........ .. � ..: A9 K " 5tv....0 /...v? 7t; x ......,n " ... ..... i � f } � 4 t __�. _ �,= .�..d .� _ ..�., � , ,;x . , .. • _. < « _. _ .. ,, .. _ _.. __ _ . _ ` .. .. g, - � a � � ,' �i R `; FD , • G . j - ABOVE CEILING . :- "':,-^"t. . • a ?tY14.4 r S TOTAL DEMAND = 25. 4= @ 7 W.C. �i01 DEVELOPED LENGTH OF PIP -OM U S 50,6 M METER = 200 FEET. w � Pie ®� �d p • :; — ,:.. � 1 ;• • : p • '` a 00 �` " w , w A AL P LU M B I N PLAN (GA G <3 `i p 3 e i � L � r � m > - - -_ - -, � � r - � 1 M - n\-...eik - SCALE : NONE - PART - "' I • _ € F° - \ �.. s \� • vim -, 11/2" 1 1 \V. 2n I 1 . OD �• � _ 3/4 " G I ,/ 1 1 -,. 9 � NOTE: INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS. VACUUM BREAKER • � ° s , -- , � - �Cp � BY P.G. EXPANSION TANK UNION BY P.G. (TIT.) _ ._., , ., ,b ( 1 I 1 1 - 0 FD :w os _MM,,. ,:��,a,w :.._,_ �, . �,�.. ; r µ 1 "} 1 1 1/2" 1 1/2 I 1 I 1 T �' I ∎ I 1 I I �' 1 1 1 1/2" 1 C•4% I "� 1/2 n 1/2 • i 3/4" 3/4" /2" 1�L F �-.� A `= u e t — a - _ ,-• , ry '• . ::.� !es _.� ,rna.¢�.� :c- i.•nzaa'Y! • riex M1,:.. '..r,. pt k > :-:;.:,.w: ,;, .. � . :. s r ` A � - HW MTROL ST - 5 � 3 /4 " - WATER HEATER 51=1= PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. I EWC ( 11 1/2 I 1 ■ 1 I 2" r ∎2 �` a 3 " 1 �� 2 - f A'. I ■ ■ 2 "� � 1 I/2 I- a I rl f " 1/2 L A r I � Pl.t ""CW 3/4 GATE/BALL VALVE BY P.C. (TYP.) CHECK VALVE PLUMBING SYMBOL LEGEND 4" I " 1 1/2 I 3/4" n FD , 3" 1 1 v LAV I 1 �7 \ \ 0 \ B.D.- BUILDING DEPT. T.D.- TENANT DIRECTIVE G.C.- GENERAL CONTRACTOR DIRECTIVE L.L.- LANDLORD DIRECTIVE 2 WIDE, 20 GA. SHEET METAL BAND, SECURE TO WALL FOR SEEISMIC DETAIL DISCRIPTION DETAIL DISI RIPTION G 311 1/2' WC L EWC 10 ; (TYP.) 4" P1.1 LA 1 3" ■ -vim 1 1 I 1/2" 1/2' i � Q K' 3/4 "T * P RELIEF BRACING WHERI± REQUIRED BY CODE. (BY P.C.) SAN SANITARY WASTE SANITARY PIPING FCO FLOOR CLEANOUT FD V 3a .IN 1 1 1/2 a LAY . MS ■ 1/2 I I i VALVE BY P.C. 3/4" RUN FULL r 0 411 4" E. 4" 1 1 FD I J 00 LAV i + � GALV. DRIP PAN 8Y P.G. SIZE TO MOP - - - - - V- - - --- - VENT PIPING MO II-O WALL CL EANOUT BASIN. I— --- --4 - 3 " 10 1/2" DRAIN VALVE BY P.C. I � COLD ATER NG I l I•I/ SEPARATE 3/4 11 NWC // / //// PLYWOOD PLATFORM BY GENERAL CONTRACTOR' i:i HOT WATER PIPING O WATER METER GAS PIPING GAS SHUT-OFF AND UNIT P1 -1 P1.1 G I, SANITARY STACK DIAGRAM SCAT E : NONE E WATER RISER DIAGRAM SCALE : NONE B PARTIAL PLUMBING PLAN SCALE : 1/4' = 1 O 1 WATER HEATER MOUNTING SCALE : NONE S CONNECTION TO EXISTING STRAINER, FLUSH FINISHED FLOOR (SEE WITI FLOOR "DREAMSTEAMER" PLUMBING NOTES: 30 AMP. INDIVIDUAL WATER SHUTOFF VALVE MUST A SECURELY MOUNTED IN AN A EA ACCESSIBLE LOCATION WITHIN FIVE FEET OF THE LEFT SIDE OF THE MACHINE BALL TYPE SHUTOFF VALVE ISSUE DATE: 1 PERMIT DATE: 9/15/07I 1 LANDLORD DATE: 9N4/07I BID DATE: 9/15/071 - � 1 coos -Lx-t saILsvw 1 g' :NH3 E NEAREST AVAILABLE COLD WATER SOURCE (COLD WATER INPUT TO WATER TAP INTO THE NEATER, DRINKING FOUNTAIN, BATHROOM, ETC.) USING 1/2" COPPER LINE OR TUBING. HANGERS (MUST BE AT DECK ABOVE THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A 1/2" THREADED BALL TYPE 6" BEFORE DROP) — SHUT -OFF VALVE MOUNTED TO THE WALL IN AN EASILY ACCESSIBLE LOCATION. BRANCH CIRCUIT - BACKFLOW VALVE PER LOCAL PLUMBING CODE y I/2" COPPER LINE OR TUBING ACCESS PANEL BY G.C. 72 INCHES OF STAINLESS STEEL BRAIDED TUBING AND THE HARDWARE TO CONNECT TO A 3/8" 1 \------ JOIST/BEAM • BALL VALVE WILL BE INCLUDED WITH THE MACHINE. BALL DOES NOT NEW TO BE CONNECTED. 1/2 11 TYPE a L 1� WATER SUPPLY, CLAMP TO WALL AT TOP, _ -1 1 ARCHITECTURAL FOR FLOOR SLOPES) - 0 - AND BOTTOM. - w • • • • • • • • • = MIDPOINT ADJUSTABL^ — DRAIN HEAD ALL CANADIAN AND CERTAIN U.S. LOCATIONS REQUIRE THE USE OF A BACKFLOW VALVE. CHECK YOUR LOCAL PLUMBING co. DE op _ • 4 .a THE WATER LINE WILL NEED TO BE BLED AND FREE OF DEBRIS BEFORE IT 15 CONNECTED TO PROVIDE A 3!8" THE MACHINE, AFTER CONNECTING GLEAN INTERNAL STRAINER AND CYGLE WATER UNTIL BALL VALVE STRAINER REMAINS CLEAR. 1/2" TYPE "L" VENT PIPE DN TO THE WATER PRESSURE MUST NOT EXCEED 100 PSI. IF THE WATER PRESSURE 15 GREATER THAN I" AFF ADJACENT TO 1/2" 100 P51 THEN A 50 P5I REGULATOR WILL NEED TO BE INSTALLED. WATER SUPPLY. TURN OUT TOWARD FLOOR DRAIN ` • - ' ' • ' v :, `p REDUCER CONCEPT 5 115 WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY SEATTLE, WA 98188 • - a • - - \ ■ • N _al 4 . • !• - • DRAIN BODY • • CEILING WALL BY CONTRACTOR DRAIN (DO NOT CONNI =CT) , / 0 DREAM- STEAMER BY OWNER T. 350# ^ = „es ' IN WALL ACCESS PANEL AC G.C. FINISHED FLOOR 1/2" X 3/8" REDUCER FITTING 3/8 �� COILED �� COPPER TUBING c [ _ • f �, 1 INSIDE CAULK DRAIN SUPPORT STRAP .� WATTS SERIES "D l" ASSE1012 ■ ■ � STANDARD DOUBLE GH1±GK ' 1 � � PIPE WALL BACKFLOW PREVENTER - APPROXIMATELY DRAWN: MM n ■ m =N-- "DREAMSTF.ANER" NOT!~: u l/2 BACKFLOW PREVENTER VENT SIX FEET BY MANUFACTURER. & 1-� U ' ` : . ' > 20 3/8" BRAIDED COPPER ° O OIF A. FLOOR DRAIN DOVER FLUSH WITH TILE OR FLUSH WITH CONCRETE FLOOR IN AREA WITH NO TILE. B. CONTRACTOR TO SNAKE DRAINS 2 DAYS PRIOR TO OPENING. TUBING BY MANUFACTURER PROVIDE 6' OF 3/8" BRAIDED c' D . �R tONS 30 AMP. 3 -POLE 4 -WIRE GROUNDING RECEPTACLE WITH NEUTRAL (NEMA L15 -30). SEE ELECTRICAL SHEETS 1 ,- •; i s =� A` 3 Y L.,' rt.,_ _ " : `t € �',`, ®Bp i �� p �g gg Shall be n�ad� �tl'1B Of w&k with prnoq ppgavaI 01 ' „ COPPER TUBING AND CONNECT TO )• / 6 48 " STEAMER BY MANUFACTURER. :P 4 FOR FURTHER INFORMATION. - Tukwila B uilding Division . NO TE: Revisions wil require new plan submittal and may include additional plan review fees 1 / PLAN VIEW SECTION VIEW FLOOR DRAIN DETAIL SCALE : NONE H DREAMSTEAMER PIPING SCALE : NONE 1 DREAMSTEAMER INSTALLATION SCALE : NONE DI PLUMBING FIXTURES SUPPLY & DRAINAGE FIXTURE UNITS . FILE COPY Pelt � ' Plar revi9Vll8 **OSb1111d Oval Cd OOf�1 amounts does ned authorize violation deny d ode ora of app - = s J, and fondness is adermiledged: /% �� DSGNR: MB WC WATER CLOSET: AMERICAN STANDARD "CADET" MODEL 2377.100, FLOOR MOUNTED TANK TYPE PRESSURE ASSISTED WATER CLOSET, VITREOUS CHINA. ELONGATED BOWL. CLOSED COUPLED FLUSHMETER TANK. 1.6 GALLONS PER FLUSH. WHITE COLOR. 17" RIM HEIGHT WITH WHITE RI5E- AND -SHINE ELONGATED OPEN H H FRONT SEAT AND COVER #5325.024. FLUSH TO BE ON OPEN SIDE OF WATER CLOSET. LAV LAVATORY: AMERICAN STANDARD MOUNTED AT WHEELCHAIR HEIGHT MODEL 0124.131. WALL MOUNTED 18.5" x 20" VITREOUS CHINA. 4" CENTERS. WHITE COLOR. BASED ON COPPER TUBE PIPING. POMESTIC COLD WATER FU'S FU'S GPM (2) BATHROOM GROUP'S (PUBLIC) 7.20 (1) MOP BASIN 3.00 (1) EWG 0.25 (1) DREAMSTEAMER 0.25 SCALE:As NOTED PROVIDE JOSAM 17105 -67 SERIES CARRIER, CHICAGO #Sq5 -317CP GOOSENECK FAUCET WITH 4" CENTERS, BLADE HANDLES AND CHICAGO VANDAL RESISTANT ECONO -FLO WATER CONSERVING AERATOR #£2805 -5. MCGUIRE #158-94C SUPPLY STOP, MCGUIRE #1S5 -WC STRAINER WITH OFFSET TRAP. ., MOP BASIN: FIAT MODEL M515-2424. 24" x 24" x 10 ", MOLDED STONE SERVICEPTOR, VINYL BUMPERGUARD. PROVIDE #832.AA 36" LONG, 3/4" HOSE AND BRACKET WITH WALL HOOK AND CHICAGO #8q7 FAUCET WITH INTEGRAL VACUUM BREAKER. WI-1 ELECTRIC WATER HEATER: A .O. SMITH MODEL ELJF -6, 6 GALLON ELECTRIC WATER HEATER, 1500 WATT ELEMENT. GLASS LINED, FOAM INSULATION. BAKED ENAMEL FINISH. 120 VOLT 1 PHASE. E FLOOR DRAIN: JOSAM #30003- 5A -50, 3 11 FLOOR DRAIN WITH NICKEL BRONZE FINISH AND TRAP PRIMER INLET CONNECTION. PROVIDE DEEP SEAL TRAP. TP TRAP PRIMER: PRECISION PLUMBING PRODUCTS MODEL P2 -500 TRAP PRIMER VALVE, WITH DU -2 DISTRIBUTION UNIT AND 55 -8 SUPPLY TUBE FOR USE WITH UP TO 2 FLOOFLOOR DRAINS. ENG ELECTRIC WATER COOLER: OASIS MODEL P8ACL, WALL MOUNTED HI -LOW HANDICAPPED ELECTRIC WATER COOLER. STAINLESS STEEL CONSTRUCTION. 4 -TIMED 10.70 15.0 COLD WATER PIPE SIZE = 3/4" MIN. pOr(ESTIC SANITARY FU'S FU'S SEPARATE PERMIT 7-3o o DMA. REQUIRED FOR: ['Mechanical CItY of Tukwila �£lacirica► BUILDING DIVISION 0 Pl , Bing • Gas Piping City of TUk lea BUILD 1NG D 1V1�1C - - RECEIVED CITY OF TUKWIIA Dui 042007 PERMIT CENTER F , :s ' van S WAS tr a l . C . �o � . , y , f ) 7 . ` :• �:° .. w %. ..• '°= 2l•' .1 w, (2) BATHROOM GROUP'S (PUBLIC) 10.0 (1) MOP BASIN 2.0 (1) EWG 0 5 12.5 SANITARY PIPE SIZE = 4 " TOUCH PADS. 8.0 GPI4 @ 50 DEGREES F. 1/4 HP, 4.6 AMPS, 115 VOLT /1 PHASE. PROVIDE WITH TRAP AND A BALL VALVE ON SUPPLY LINE. MOUNT WITH BUBBLER AT W A.F.F.' NCO NALL CLEAN OUT: CAST IRON CLEAN OUT TEE WITH BRONZE THREADED, WATER AND GAS TIGHT CLEAN OUT PLUG. JOSAM #58604 -PLG4, WALL ACCESS PANEL 5 -I/2 "0 SMOOTH NICKEL BRONZE, SET FLUSH TO FINISH WALL PLANE. FURNISHED WITH SECURING LUGS. FCO FLOOR CLEAN OUT: JOSAM #57004 -SD -2. CAST IRON BODY WITH GAS AND WATER TIGHT ABS TAPERED THREAD PLUG AND ROUND SCORIATED TOP EXPIRE' M sr ADJUSTABLE TO FINISH FLOOR. ABFC50017 SHEET P1.1