HomeMy WebLinkAboutPermit PG07-274 - WESTFIELD SOUTHCENTER MALL - SEPHORASEPHORA 616 SOUTHCENTER MALL PGO7-274 Parcel No.: 6364200010 Address: Suite No: Owner: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 616 SOUTHCENTER MALL TUKW Tenant: Name: SEPHORA Address: 616 SOUTHCENTER MALL , TUKWILA WA Name: WEA SOUTHCENTER LLC Address: 11601 WIISHIRE BLVD , LOS ANGELES CA Contact Person: Name: TIM SCHENK Address: 1120 E 80 ST, STE 211 , BLOOMINGTON MN Contractor: Name: SCHEINER COMMERCIAL GROUP Address: 18965 BASE CAMP RD STE Al , MONUMENT CO Contractor License No: SCHEICG958N2 PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Expiration Date: 08/22/2009 DESCRIPTION OF WORK: PLUMBING FOR NEW TI: INSTALLATION OF (2) NEW RESTROOMS. WORK TO INCLUDE NEW FIXTURES AND PIPING. Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet $5,000.00 $207.50 FIXTURE TYPE AND OUANTITY * *continued on next page ** Phone: Phone: 800 541 -0821 Phone: 719- 487 -1600 PG07 -274 03/10/2008 09/06/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 1 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 2 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 2 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 PG07 -274 Printed: 03 -10 -2008 Permit Center Authorized Signature: City or Tukwila I hereby certify that I have read and examined this governing this work will be complied with, wheth Signature: doc: UPC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us e The granting of this permit does not presum= ..e - --v c., construction or the performance of work. I �► r,16 :: Permit Number: PGO7 -274 Issue Date: 03/10/2008 Permit Expires On: 09/06/2008 Date: rmit and know the same to be true and correct. All provisions of law and ordinances ecified herein or not. to violate or cancel the provisions of any other state or local laws regulating d to sign and obtain this plumbing /gas piping permit. aa Date: V- O g Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 - 274 Printed: 03 -10 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: SEPHORA 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 616 SOUTHCENTER MALL TUKW PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -274 ISSUED 10/12/2007 03/10/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -274 Printed: 03 -10 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does n • esume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performanc;,,44' Signature: Date: V Print Name: S -t 0 doc: Cond -10/06 PG07 -274 Printed: 03 -10 -2008 Site Address: Name: Company Name: CITY OF TUKWIL` Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 lutp://www.ci.tuk-wila.wa.us Z• sA0 ptS16r4 G2QVP Contact Person: fAA(L4 WNW,- • Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bit Public Works Permit No. sovrl4CI Nr . PAr1JGNArY Building PermifNo. Mechanical Permit No. U - Plumbing/Gas Permit No. 1 "— Project No. Pp 1 -111 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** City (For office use only) SITE LOCATION King Co Assessor's Tax No.: Suite Number: 1120 Floor: Tenant Name: SE.P14ORA New Tenant: PI( Yes ❑ ..No Property Owners Name: N.Sf eLo GO1•WO ZA1X 4 , 1 of L. •• Mailing Address: 110 1 W L•51k1Re BWO SVIIE' 1100 , LOS Rf GetZ5, CA ( State City State E -Mail Address: +trs.S °Q etake-Y'30 h $. corr.. Fax Number: 4 112. '6.54 • 4 4909 State E -Mail Address: Fax Number: 4 1( S • 391 kr O Company Name: M • ¶b Pet L- eriG1 rnl E E(LM/G 1 I r^(C- Mailing Address: — 750 g(1mv.sGOCst ( tQ , I4 S((E'Y)(lu -c Okk 1.43081 City Day Telephone: 6 (9 • X1• UZ3 Zip CONTACT PERSON — who do we contact when your permit is ready to be issued '� rl1 S C I4IEN V. Day Telephone: 1'$k° • 5 I.OEZ) Mailing Address: 1120 G • SA Sr . wire 741, actmt 4GSOr{ , S•5'42Q Zip GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: T. (. (� Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Mailing Address: 411 MONtGornertY sree r Sp rr'aArICtsco C.A 1 14101? City State Zip Day Telephone: 41s- •3q13 • SSOO ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record State Zip Contact Person: -JASCS 4 1411 PemAr r E -Mail Address: Fax Number: (14 • S 1 • 7 331 Page 1 of 6 BUILDING PERMIT INFOR,TION - 206 -431- 3670 �-� Valuation of Project (contractor's bid price): $ 3 S 000. u-2 Existing Building Valuation: $ Scope of Work (please provide detailed information): 13'i Q I r OF tm1 L. 14/.1"tT SPAC fry Tse N€H! m/1tA, PANS) 01.4 nE4, Will there be new rack storage? ❑ Yes D.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1 Floor 2nd Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached - Carport Covered Deck Uncovered Deck Interior Remodel PLANNING DIVISION: Single family building footprint (area of -'e foundation of all structures, plus any decks over 18 ches and overhangs greater than 18 inches) *For an Accessory dwelling, provide following: Lot Area (sq ft): Floor area of principal dwelling: loor area of accessory dwelling: *Provide documentation t shows that the principal owner lives in one of the dwellings as his • er primary residence. Number of Parking Stalls Prod ed: Standard: Compact: Handicap: Will there be a change in us ❑ Yes Int No If "yes ", explain: FIRE PROTECTIO ' /HAZARDOUS MATERIALS: Addition to !' Existing Structure ew pe of !. struction per IBC • Type of Occupancy per IBC Spri . ers gg Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Wpplications\Foans- Applications On Linet3 -2006 - Permit Application.doc Revised: 9 -2006 bit Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain '2.- Sinks 2- Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system - per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets/outlets - six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas t PLUMBING AND GAS PIPING RNIIT INFORMATION - 206- 431 -*70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: T•Q•n Mailing Address: Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: / (rent Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): 14S1 CI' IKO t '(K (ICSf?L00MS / I (EfI L 1, T'rYia•rr Sf L& 1-11311G to iNUJVC ,tCu FixNt3 a r gPl•rt. Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: QMpplications\Ponns- Applications On Line13 -2006 - Petmit Applicationdoc Revised: 9 -2006 bh City State Zip Sewer. Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU H RIZED AGENT: Signature: '� J Print Name: Tim S C.UE *I Day Telephone: Mailing Address: It'W F• 4 44 W. W. ski t . '211. a1/400entr4c41r.f Ont 5 2.) City Date Application Accepted: to I p4 Date Application Expires: b`l1l2(0) Staff Initials: Q: &pplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bit Date: State Zip Page 6 of 6 Parcel No.: 6364200010 Permit Number: PG07 -274 Address: 616 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/12/2007 Applicant: SEPHORA Issue Date: Receipt No.: R08 -00667 City of Tukwila Initials: WER Payment Date: 03/10/2008 08:48 AM User ID: 1655 Balance: $0.00 Payee: SCHEINER COMMERCIAL GROUP TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2504 168.00 ACCOUNT ITEM LIST: Description PLUMBING - NONRES Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 168.00 Total: $ 168.00 Payment Amount: $168.00 9684 03/10 9710 TOTAL 2597.24 doc: Receiot -06 Printed: 03 -10 -2008 RECEIPT NO: R07 -02245 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: /hvww.ci.tukwila.wa.us Initials: JEM Payment Date: 10 /12/2007 User ID: 1165 Payee: ELDER -JONES SET ID: S000000876 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -386 1,342.11 EL07 -583 123.00 M07 -220 82.49 PG07 -274 39.50 TOTAL: 1,587.10 TRANSACTION LIST: Type Method Description Amount Payment Check 50014 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Total Payment: 1,587.10 1,587.10 1,587.10 Account Code Current Pmts 000.345.832.00.0 123.00 000/345.830 1,464.10 TOTAL: 1,587.10 Project: Se, AU t'.44 Type of Inspecti n: � , : U/1 (--- P /v h Address: l0 /14 /31 / Date Called: Special Instructions: Date Wan t ed: qm: m ' Requester: Phone No: –7/9-57° -3 qo P607-Z7 INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1g- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Pi,i i i /(__ rp/c /i /L 'U/ Inspecto Date: .4.s_Pit 6 -/8 -5A "• 0.00 REINSPECT N FEE , / UIRED. Prior to inspection, fee must be paid at 6300 Southcenter B ., Suite 100. Call to schedule reinspection. Receipt No.: !Date: Project: .5( Pfid 1 -143 Type offri / pection: , A/ 4 ( Address: 6/6. A77/9/7 Date Called: Special Instructions: Date Wanted: — / - 7 -69 _ 9 -- a.m. Requester: Phone No: - 7/- -37 0 - 33 1 -4 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 El Approved per applicable codes. COMMENTS: =174 7 "i" IA-e 404 iii4d4d;OPt ;11 prope !Inspector: Ped7Z7-1 Corrections required prior to approval. r ate. (, / /or El $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid t6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: // 51/04.o� Type of Inspection: / I x} i /� ,31'" f Address: 61k so,►tin -fY,ri src/rzo Date Called: Special Instructions: Date Wanted:e 3 -7, r'ot's p.m. Requester: Phone No: 4- 1 2 5` 26 3 UP INSPECTION RECORD Retain a copy with permit 07 1 274 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: nn� 1 �'i I o lC 'Date: 2 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: IP6 7 — e 7( (i INSPECTION NO. PERMIT NO. ' CITY OF TUKWILA BUILDING DIVISION 42 . 6300 Sou thcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 INSPECTION RECORD Retain a copy with permit F4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: lnsp $58.0 paid Receipt Dle/zWort, NSPECTION FEE REQ HIED. Pr • r to inspection, fee must be 00 Southcenter Blvd.. S ite 100. the schedule reinspection. 'Date: Type oft 4 Proje&s.)0/4014 Address: chrMar4hii nh// Date Called: Special Instructions: Date Wanted: Ckr p.m. Requester: Ph r;pN t3 g,3 ( IP6 7 — e 7( (i INSPECTION NO. PERMIT NO. ' CITY OF TUKWILA BUILDING DIVISION 42 . 6300 Sou thcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 INSPECTION RECORD Retain a copy with permit F4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: lnsp $58.0 paid Receipt Dle/zWort, NSPECTION FEE REQ HIED. Pr • r to inspection, fee must be 00 Southcenter Blvd.. S ite 100. the schedule reinspection. 'Date: 03 -05 -2008 TIM SCHENK 1120 E 80 ST, STE 211 BLOOMINGTON MN 55420 RE: Permit Application No. PG07 -274 616 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 10/12/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 04/09/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/09/2008. If it is determined that an extension is granted, -your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. xc: Cr Marshall it Technician Permit File No. PG07 -274 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 October 24, 2007 Tim Schenk 1120 E 80 St, Ste 211 Bloomington MN 55420 RE: CORRECTION LETTER #1 Plumbing /Gas Piping Application Number PG07 -274 Sephora — XXX Southcenter Mall, Ste 1120 Dear Mr. Schenk, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throu;Dh the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, encl shall ician xc: File No. PG07 -274 City of Tukwila ila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director P :'Permit CenterCCorrection Letters 120071PG07 -274 Correction Ur #1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: October 24, 2007 Project Name: Sephora Permit #: PG07 -274 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. A drinking fountain shall be required. The Plumbing Fixture Schedule shows a drinking fountain, however the drinking fountain is not shown on the plan. In addition the drinking fountain pipe is shown in the hot water (I 1W) column. Please revise plumbing fixture and provide for a drinking fountain. (IBC 2903.4.1) Should there be questions conceming the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: PG07 -274 DATE: 11 -16 -07 PROJECT NAME: SEPHORA SITE ADDRESS: SOUTHCENTER MALL, STE 1120 Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buil d ing D 'vision Ai n Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 �- PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: C ❑ ❑ Permit Coordinator DUE DATE: 11 -20-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 12-18-07 Approved ❑ Approved with Conditions rvi Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Planning Division n n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG07 - 274 DATE: 10 -12 -07 PROJECT NAME: SEPHORA SITE ADDRESS: XXX SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: B I • n g Division aLi Public Works nt14IA J n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 *d03 08003 liwaaa PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete n ❑ Permit Coordinator ❑ DUE DATE: 10-16 -07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUJING: Please Route FO Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: Planning Division Approved ❑ Approved with Conditions n Not Approved (attach comments) (� Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: t�2 Departments issued corrections: Bldg 1'.1 Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 11-13-07 Date: t 1 ' ►� •G1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Sephora City of Tukwila Project Address: XXX Southcente \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: PG07 -274 Ste 1120 Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED Cfly OF rUKWILA NOV 16 2007 PEkMn GINTEh Contact Person: TIt SQ& 1tt - Phone Number: 1 .134 0 •S4 I 4a2,J Summary of Revision: © ar.A. O C`{ c 1 Me (r ACtt hl {c fret- (014 VAS, s( "CGFt•al A.440 Su4e7X .E' WAS OCAStre0 . PwtnSjr P(IW •ttaq, s acz (lc t 2tsert. 1 ANO V t3cr ('.E urAt sct-14470YLr vot1S aesitsw0 Pcn,# Nei./ Otio4k Aver/m.4 sac Pie P.1. Sheet Number(s): 4 1 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by Entered in Permits Plus on License Information License SCHEICG958N2 Licensee Name SCHEINER COMMERCIAL GROUP INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602521371 Ind. Ins. Account Id TREASURER Business Type CORPORATION Address 1 18965 BASE CAMP RD STE Al Address 2 City MONUMENT County OUT OF STATE State CO Zip 80132 Phone 7194871600 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 8/22/2005 Expiration Date 8/22/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SCHEINER, JOSPEH R PRESIDENT 08/22/2005 Bond Amount SCHEINER, JEFF TREASURER 08/22/2005 SCHEINER, KELLEY L VICE PRESIDENT 08/22/2005 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date WESTERN SURETY Until Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SCHEICG958N2 03/10/2008 PLUMBING FIXTURE SCHEDULE MANUFACTURER: AS NOTED, NO EXCEPTIONS FIXTURE UNITS (SAN) FIXTURE NO. FIXTURE TYPE WASTE VENT CW HW REMARKS SK-1 SINK 2" 1 -1 /2" 1 /2" 1 /2" MELKAY ODEL 2302 GOOSENECK FAUCET. TYPE CHICAGO FAUCET STEEL, 2 CONFORMS TO ADA REQUIREMENTS. �S. SUPPLY WITH CHICAGO FAUCET 2.0 WF WATER FILTER - - 3/8" - IN- SINK - ERATOR MODEL F -201 0.75 GPM. PROVIDE WITH 2 ADDITIONAL MODEL F -201R CARTRIDGES. MS GD GARBAGE DISPOSAL 2" - - - IN-SINK-ERATOR BADGER 5XP 3/4 HP MOTOR - EWH ELECTRIC WATER HEATER _ _ 3/4 " 3/4" A.O. SMITH ELECTRIC WATER HEATER MODEL DEL -10, 3.0 KW, 10 GALLON. MOUNT ON PLATFORM ABOVE TOILET ROOM. PROVIDE WITH 4" DRAIN PAN AND AMTROL EXPANSION TANK MODEL THERM -X- TROL- ST -5 -C. SEE DIVISION 16 DRAWINGS FOR VOLTAGE AND PHASE. 0.5 LAV WALL HUNG LAVATORY 2" 1 -1/2" 1/2" 1/2" KOHLER GREENWICH MODEL K -2032 VITREOUS CHINA LAV WITH KOHLER K- 15592 -F -CP SINGLE LEVER FAUCET. MOUNT LAVATORY AT 34" A.F.F. TO TOP OF SINK RIM FOR USE BY HANDICAPPED PERSONS UNLESS OTHERWISE NOTED BY ARCHITECT. TP TRAP PRIMER - - 1/2" - JAY R. SMITH PRIME EZE WATER SAVER TRAP PRIMER MODEL NO. 2698 WC -1 WATER CLOSET 3" 2" 1/2" - THE ELONGATED 2 -PIECE TOILET COMBINATION SHALL BE 12" (30.5 CM) ROUGH -IN. TOILET SHALL BE MADE OF VITREOUS CHINA. TOILET SHALL BE AT COMFORT HEIGHT. TOILET SHALL BE 1.6 GPF (6 LPF) OR 1.4 GPF (5.3 LPF), WITH CLASS 5 FLUSHING SYSTEM. TOILET SHALL HAVE 2 -1/8" (5.4 CM) GLAZED TRAPWAY. TOILET SHALL INCLUDE POLISHED CHROME TRIP LEVER. TOILET SHALL BE ADA COMPLIANT WITH 16 -1/2" (41.9 CM) HIGH BOWL. TOILET SHALL BE LESS SUPPLY. TOILET SHALL HAVE EPDM FLAPPER. TOILET SHALL HAVE 11.3/4" (29.8 CM) X 9 -1/4" (23.5 CM) WATER AREA. TOILET SHALL BE KOHLER MODEL K -3496. PROVIDE WITH K -4664 BREVIA SEAT WITH COVER. WC -2 WATER CLOSET 3" 2" 1/2" - THE ELONGATED 2 -PIECE TOILET COMBINATION SHALL BE 12" (30.5 CM) ROUGH -IN. TOILET SHALL BE MADE OF VITREOUS CHINA. TOILET SHALL BE AT COMFORT HEIGHT. TOILET SHALL BE 1.6 GPF (6 LPF) OR 1.4 GPF (5.3 LPF), WITH CLASS 5 FLUSHING SYSTEM. TOILET SHALL HAVE 2 -1/8" (5.4 CM) GLAZED TRAPWAY. TOILET SHALL INCLUDE POLISHED CHROME TRIP LEVER. TOILET SHALL BE ADA COMPLIANT WITH 16-1/2" (41.9 CM) HIGH BOWL. TOILET SHALL BE LESS SUPPLY. TOILET SHALL HAVE EPDM FLAPPER. TOILET SHALL HAVE 11 -3/4" (29.8 CM) X 9 -1/4" (23.5 CM) WATER AREA. TOILET SHALL BE KOHLER MODEL K- 3496 -RA. PROVIDE WITH K -4664 BREVIA SEAT WITH COVER. MS MOP SINK 3" 1 -1 /2 3 4 3 4 FIAT MSB -2424 24x24 SQUARE MOLDED STONE MOP SINK WITH 10" HIGH SIDES. PROVIDE CHICAGO FAUCET MODEL 540- LD897SWXF FAUCET WITH INTEGRAL VACUUM BREAKER, PAIL HOOK, 3/4" HOSE THREADED SPOUT, AND 3" OUTLET WITH DOME STRAINER. GF GLASS FILLER /HOT WATER DISPENSER _. - - 1 / 2 " - IN- SINK - ERATOR MODEL F- HC1100 INSTANT HOT AND COLD WATER DISPENSER 115V/750 WATT 6.5 AMP W/ 3 PRONG PLUG U.L. LISTED TEMPERATURE ADJUSTABLE FROM 140' -200'F FD FLOOR DRAIN 2" 1 1/2" - - JOSAM SERIES NO. 30000A -6A WITH 3" UNE AND 6 NICKALOY ROUND STRAINER. PROVIDE WITH JAY R. SMITH MODEL 2698 TRAP PRIMER OR EQUAL. CO FLOOR CLEAN OUT LINE SIZE _ - - JOSAM SERIES NO. 55000 -Z WITH NICKALOY ROUND CAP. WCO WALL CLEANOUT LINE SIZE - _ - WALL CLEAN OUT - CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL ACCESS PANEL - ZURN #ZANB- 1460 -9, 9" X 9" WALL ACCESS PANEL AND FRAME; SMOOTH NICKEL BRONZE SECURING LUGS. ACCEPTABLE ALTERNATES, WADE OR SMITH. TMV THERMOSTATIC MIXING VALVE SIZE SIZE POINT OF USE. WATTS MODEL MMV- US -M1. DF -1 DRINKING FOUNTAIN 2" 1 -1/2" 1/2" OASIS BARRIER FREE WATER COOLER MODEL NUMBER P8AC. CONTRACTOR SHALL FURNISH WITH ALL ACCESSORIES AND MATERIALS NECESSARY FOR A COMPLETE OPERATIONAL INSTALATION. PLUMBING FIX. UNIT COUNT FIXTURE TYPE FIXTURE UNITS (SAN) FIXTURE UNITS (WATER) NO. OF FIXTURES TOTAL FIXTURE UNITS (SAN) TOTAL FIXTURE UNITS (DOM) WC 4.0 2.5 2 8.0 5.0 5K -1 2.0 1.5 1 2.0 3.0 LAV 1.0 1.0 2 2.0 2.0 MS 3.0 3.0 1 3.0 3.0 FD 2.0 - 2 4.0 - DF -1 0.5 0.25 1 0.5 0.25 ISSUE DESCRIPTION TOTAL 19.5 13.25 5 WC RISER N.T.S. 4 1 1/2" WCO WC -1 » » 1 1 - A A / 2"i ` 1> r 2 FD LAV •I LAV =�= 1 1/2"--1 „ FD N.T.S. 3 STACK 3 WC -1 " WCO .'1 CO 1 1/2" SK -1 6 » REVISIONS I No ct,anges sha e rnadn to�tthr,, scorIP f of worst v�.�i i 3i;t., p' i... _ , ot Tukwila Building Division. se�bm tal i NOTE' Revisions will require a new fees. j and may include additional plan . - re FILE COPY Permit No. Plar review approval �$ Approval of constmotion the violation of any of approved Field BY Date :. I 2 I u' - City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: (Mechanical � Electrlcai ❑ Plumbing ❑ Gas Piping rtit of Tukwila U : E)Imo DIVISI to mots aid omission& does not aModze Asuipt PLUMBING CODED NOTES: CONNECT NEW 4" SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE AS SHOWN. FIELD VERIFY EXACT LOCATION OF LANDLORD'S MAIN BEFORE STARTING WORK. CONNECT NEW 2" VENT LINE FROM TENANT'S PLUMBING FIXTURES INTO THE LANDLORD'S EXISTING VENT MAIN AS SHOWN. FIELD VERIFY EXACT LOCATION OF LANDLORD'S VENT BEFORE STARTING WORK. 03 CONNECT NEW 3/4" COLD WATER LINE INTO THE LANDLORD'S EXISTING WATER LINE BEFORE STARTING WORK. PROVIDE WITH WATER METER IF REQUIRED BY LANDLORD. VERIFY METER TYPE AND LOCATION WITH LANDLORD'S ON SITE REPRESENATIVE. �4 FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM AND AS REQUIRED. UNITS AS SUPPLIED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOPS OR VALVES TO ISOLATE EACH FIXTURE. �5 ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. ® PLUMBING CONTRACTOR TO PROVIDE AND INSTALL GARBAGE DISPOSAL AT LOCATION OF SK -1. PROVIDE WITH ALL ACCESSORIES AND MATERIALS NEEDED FOR A COMPLETE INSTALL. �7 PLUMBING CONTRACTOR TO PROVIDE AND INSTALL WATER FILTER PER SCHEDULE ON THIS SHEET. ® THERMOSTATIC MIXING VALVE TO BE PROVIDED AND INSTALLED AT EACH SINK AND LAVITORY. g� PLUMBING CONTRACTOR TO PROVIDE AND INSTALL GLASS FILLER AS SCHEDULED ON THIS SHEET. PROVIDE ALL MATERIALS AND ACCESSORIES NEEDED FOR A COMPLETE INSTALL. 10 PLUMBING CONTRACTOR TO PROVIDE AND INSTALL WATTS SERIES 909 BACK FLOW PREVENTOR. 2 HEAT TRAP (TYPICAL) - BALL VALVE (TYPICAL) . 1" DRAIN TO SERVICE SINK PLUMBING PLAN 1/2"=1'-0" DIELECTRIC UNION T (TYPICAL)- 4" DRIP PAN (BY PLUMBING CONTRACTOR) LANDLORD COMMENTS: - TEMP. AND PRESSURE - 44 RELIEF VALVE EWH CHECK VALVE 1 DHW -DCW I /Ho EXPANSION TANK, RUN FULL SIZE TO DRIP PAN 3/4" PLUMBING CONTRACTOR SHALL PROVIDE ANGLE IRON SUPPORT AND PLATFORM. ELECTRIC WATER HEATER SCHEMATIC N TENANTS CONTRACTOR SHALL COORDINATE UNDERSLAB PLUMBING WITH LANDLORD PRIOR TO SLAB DEMOLITION TO PREVENT DISTURBANCE OF LANDLORDS BELOW GRADE UTILITIES. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. CORRECTION LTR# 1 z1 g 17 r co, ;LIANCE AP PROVED AREA: SHEET TITLE: SCALE: DATE: SHEET NO. SEPHORA FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 DRAWN BY: REVIEWED BY: Emphaala On Excansica hi- Retail Engineering, Inc. PROJECT LOCATION: PLU 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com V BIB I Y Ur I urwv -n NOV 1 5 1001 p MCT CENTER FS JOB #0712121 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 G P_AN 5,439 SF PROJECT NO. 0712121 RECEIVED AS SHOWN P1.0 10 -08 -07 X X / l \ 11-12-07 CITY COMMENTS RE- SUBMITTAL JAH WPK 10 -08 -07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK A DATE ISSUE DESCRIPTION BY CHECK 5 WC RISER N.T.S. 4 1 1/2" WCO WC -1 » » 1 1 - A A / 2"i ` 1> r 2 FD LAV •I LAV =�= 1 1/2"--1 „ FD N.T.S. 3 STACK 3 WC -1 " WCO .'1 CO 1 1/2" SK -1 6 » REVISIONS I No ct,anges sha e rnadn to�tthr,, scorIP f of worst v�.�i i 3i;t., p' i... _ , ot Tukwila Building Division. se�bm tal i NOTE' Revisions will require a new fees. j and may include additional plan . - re FILE COPY Permit No. Plar review approval �$ Approval of constmotion the violation of any of approved Field BY Date :. I 2 I u' - City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: (Mechanical � Electrlcai ❑ Plumbing ❑ Gas Piping rtit of Tukwila U : E)Imo DIVISI to mots aid omission& does not aModze Asuipt PLUMBING CODED NOTES: CONNECT NEW 4" SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE AS SHOWN. FIELD VERIFY EXACT LOCATION OF LANDLORD'S MAIN BEFORE STARTING WORK. CONNECT NEW 2" VENT LINE FROM TENANT'S PLUMBING FIXTURES INTO THE LANDLORD'S EXISTING VENT MAIN AS SHOWN. FIELD VERIFY EXACT LOCATION OF LANDLORD'S VENT BEFORE STARTING WORK. 03 CONNECT NEW 3/4" COLD WATER LINE INTO THE LANDLORD'S EXISTING WATER LINE BEFORE STARTING WORK. PROVIDE WITH WATER METER IF REQUIRED BY LANDLORD. VERIFY METER TYPE AND LOCATION WITH LANDLORD'S ON SITE REPRESENATIVE. �4 FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM AND AS REQUIRED. UNITS AS SUPPLIED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOPS OR VALVES TO ISOLATE EACH FIXTURE. �5 ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. ® PLUMBING CONTRACTOR TO PROVIDE AND INSTALL GARBAGE DISPOSAL AT LOCATION OF SK -1. PROVIDE WITH ALL ACCESSORIES AND MATERIALS NEEDED FOR A COMPLETE INSTALL. �7 PLUMBING CONTRACTOR TO PROVIDE AND INSTALL WATER FILTER PER SCHEDULE ON THIS SHEET. ® THERMOSTATIC MIXING VALVE TO BE PROVIDED AND INSTALLED AT EACH SINK AND LAVITORY. g� PLUMBING CONTRACTOR TO PROVIDE AND INSTALL GLASS FILLER AS SCHEDULED ON THIS SHEET. PROVIDE ALL MATERIALS AND ACCESSORIES NEEDED FOR A COMPLETE INSTALL. 10 PLUMBING CONTRACTOR TO PROVIDE AND INSTALL WATTS SERIES 909 BACK FLOW PREVENTOR. 2 HEAT TRAP (TYPICAL) - BALL VALVE (TYPICAL) . 1" DRAIN TO SERVICE SINK PLUMBING PLAN 1/2"=1'-0" DIELECTRIC UNION T (TYPICAL)- 4" DRIP PAN (BY PLUMBING CONTRACTOR) LANDLORD COMMENTS: - TEMP. AND PRESSURE - 44 RELIEF VALVE EWH CHECK VALVE 1 DHW -DCW I /Ho EXPANSION TANK, RUN FULL SIZE TO DRIP PAN 3/4" PLUMBING CONTRACTOR SHALL PROVIDE ANGLE IRON SUPPORT AND PLATFORM. ELECTRIC WATER HEATER SCHEMATIC N TENANTS CONTRACTOR SHALL COORDINATE UNDERSLAB PLUMBING WITH LANDLORD PRIOR TO SLAB DEMOLITION TO PREVENT DISTURBANCE OF LANDLORDS BELOW GRADE UTILITIES. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. CORRECTION LTR# 1 z1 g 17 r co, ;LIANCE AP PROVED AREA: SHEET TITLE: SCALE: DATE: SHEET NO. SEPHORA FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 TSAO 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 DRAWN BY: REVIEWED BY: Emphaala On Excansica hi- Retail Engineering, Inc. PROJECT LOCATION: PLU 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com V BIB I Y Ur I urwv -n NOV 1 5 1001 p MCT CENTER FS JOB #0712121 SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 98118 G P_AN 5,439 SF PROJECT NO. 0712121 RECEIVED AS SHOWN P1.0 10 -08 -07 X X 5 5 I 4 3 BUILDING C ORRIDOR 11 Ill_ . .. _ . I 1 1. 1. LD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE TH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPAINCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. SPRINKLER PLAN 1/4"=V-0" ADJACENT TENANT ADJACENT TENANT SPRINKLER SYMBOLS (NOT ALL SYMBOLS USED) SYMBOL DESCRIPTION CONCEALED HEAD UPRIGHT SPRINKLER PENDENT SPRINKLER ON DROP NIPPLE DRY PENDANT SPRINKLER SIDEWALL SPRINKLER DRY SIDEWALL SPRINKLER T I 0 - r -- -. ..: ;1 - 15 1 . - - - -- n . fl . . 1 1 1 1 1 1 11 1 1 II 11 II II I1 11 II 11 1 1 11 I I 11 11 II 11 11 I 1 11 f 1 1 1 1 I 1 n' ■ 1 1 ! !I I II ... 11 I I I 1 l i l I I I'1 O // 1 ( 1 j 1 11 j! - jl 11 1 ,\ \1 / I \ 1 II 111 (I 11 II I 11 1 11 1 II ;/ i 11 1� I 11 I J I I � iii, 1 II ..i 1 I ! 1 1 1 I! fl 11 II 11 1 1 II it GENERAL FIRE PROTECTION NOTES 1. VERIFY ALL CONDITIONS IN FIELD. 2. REMOVE ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PLUMBING FIXTURES, PIPING, SYSTEMS, ETC, NOT BEING RE —USED. DO NOT JUST ABANDON. 3. THE REVISED SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED BY AN EXPERIENCED FIRE PROTECTION CONTRACTOR IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE LANDLORD. LANDLORD'S FIRE INSURANCE UNDERWRITER, AND ALL GOVERNMENT AGENCIES AND AUTHORITIES HAVING JURISDICTION OVER THE PREMISES. 4. COMPREHENSIVE SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED BY THE CONTRACTOR FOR THE APPROVAL OF THE OWNER, LANDLORD, LANDLORD'S FIRE INSURANCE UNDERWRITER AND THE FIRE RATING INSPECTION BUREAU. 5. TENANT'S FIRE PROTECTION CONTRACTOR SHALL DISCONNECT EXISTING SYSTEM FROM MAIN SYSTEM. PERFORM THEIR WORK, TEST, THEN RECONNECT THE MAIN SYSTEM. ALL COSTS RELATED TO DRAIN DOWN AND FILLS ARE TO BE BORNE BY TENANT'S FIRE PROTECTION CONTRACTOR. 6. SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED TO THE LOCAL FIRE MARSHALL AND RECEIVE THEIR APPROVAL BEFORE ANY INSTALLATION CAN BEGIN. APPROVED DRAWINGS MUST BE AT THE JOB SITE DURING CONSTRUCTION. NOTE: FOUR (4) COMPLETE SETS OF PLANS ARE REQUIRED OR SUBMITTAL FOR SPRINKLER PERMIT. 7. SPRINKLER HEADS LOCATED AT THE STOREFRONT, IN SHOWCASE WINDOWS AND IN HARD SURFACE CEILINGS MUST BE CONCEALED TYPE HEAD. HEADS LOCATED IN ACOUSTIC CEILNGS MAY —BE SEMI RECESSED TYPE. SURFACE MOUNTED HEADS ARE PERMITTED IN NON — CUSTOMER AREAS ONLY. 8. THE EXISTING SPRINKLER SYSTEM AND HEAD LOCATIONS SHALL BE MODIFIED PER TENANTS NEW FIXTURES, PARTITIONS, SOFFITS, DROP CEILING HEIGHTS. ETC. 9. ALL SPRNKLER WORK TO BE DONE BY LANDLORDS DESIGNATED SPRINKLER CONTRACTOR. MALL COMMON ?&o 72'7z( SCALE: DATE: FIRST MARKET TOWER 525 MARKET STREET, 11TH FLOOR SAN FRANCISCO, CA 94105 SHEET TITLE: DRAWN BY: REVIEWED BY: 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 Robinson Meier Juilly & Associates w ww_rmjse.corn RMJ Job No.: 07186 PROJECT LOCATION: 417 Montgomery Street San Francisco California 415.398.5500 p 415.398.5510 f www.tsaodesign.com Structural Engineers 103 Linden Avenue So. San Francisco, CA 94080 TeL 650.871.2282 Fax 650.871.2459 10 -08 -07 ISSUE FOR PERMIT JAH WPK 07 -27 -07 CLIENT /PRELIM. LL REVIEW JAH WPK / \ DATE ISSUE DESCRIPTION BY CHECK SOUTHCENTER MALL NEW STORE 633 SOUTHCENTER PARKWAY SUITE 1120 SEATTLE, WA 981 18 PROJECT NO. 0744.03 t-,: a n nnr� JOB #0712121 I C:ii1:6 I 5,439 SF 1/4 „ =1 10 -08 -07 2 1 1 SHEET NO. FP1.0