Loading...
HomeMy WebLinkAboutPermit PG07-279 - CASE RESIDENCECASE RESIDENCE 11635 44 AV S PGO7-279 Parcel No.: 3347400615 Address: Suite No: Tenant: Name: CASE RESIDENCE Address: 11635 44 AV S , TUKWILA WA Owner: Name: CASE DUANE +SALLY Address: 11635 44TH AVE S , SEATTLE WA Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 11635 44 AV S TUKW Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: RUSSELL CAHILL Address: 23313 208 AV SE , MAPLE VALLEY WA Contractor: Name: CAHILL PLUMBING AND HEATING INC Address: 23313 298 AV SE , MAPLE VALLEY WA Contractor License No: CAHILPH942JC DESCRIPTION OF WORK: RE -ROUTE DRAIN LINE THAT PRESENTLY GOES INTO SEPTIC TO NEWLY INSTALLED SEWER LINE. $3,900.00 $88.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, conunercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet * *continued on next page ** PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND OUANTITY Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 793 -9277 Phone: 425 532 -1977 Expiration Date: 04/03/2008 PG07 -279 10/17/2007 04/14/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) O Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 0 O Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 1 0 Repair or alteration of drainage or vent piping 0 O Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 O Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 PG07 -279 Printed: 10 -17 -2007 Permit Center Authorized Signatur I hereby certify that I have read an governing this work will be compli Signature: Print Name: doc: UPC -10/06 City &Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG07 -279 Issue Date: 10/17/2007 Permit Expires On: 04/14/2008 Date: 1,0111 d ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I uthorized to sign and obtain this plumbing /gas piping permit. Date: / 1 9 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -279 Printed: 10 -17 -2007 Parcel No.: 3347400615 Address: 11635 44 AV S TUKW Suite No: Tenant: CASE RESIDENCE 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. S: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be bacldilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -279 ISSUED 10/17/2007 10/17/2007 PG07 -279 Printed: 10 -17 -2007 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. A),01 ‹Ae Date: p1/9 PG07 -279 Printed: 10 -17 -2007 SITE LOCATION Site Address: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: CITY OF TUKWIL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** \ \(' 44 Rte. S . Tenant Name: Sc \ \ti (-S2, Property Owners Name: S Jc \ \ \\ (f 2 Mailing Address: \" ) y6 411 H ty(_ S Name: %)SS.IM C4\--\\ Mailing Address: >-3.313 �h Au- Cr Y os - vil ( Gtr- (i')w) C t\c)A d\ (, )-3/ -? :ff 10i s Contractor Registration Number: ( - S sue— d� Q: Applications\Forms- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4 -2006 bh Plumbing/Gas Permit No. Project No, (For offi use only) King Co Assessor's Tax No.:42 Suite Number: New Tenant: c')c % City AO (LAI Fax Number: Floor: .... Yes ❑ ..No WA % P State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Day Telephone: ate- '463 1 o State Zip cifyDrigx PLUMBING / GAS PIPING CONTRACTOR INFORMATION "kit `lj t" Tate Zip Day Telephone: ( IX- <' /CJ9 Fax Number: 'f- y.� Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip State City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Recor Company Name: Mailing Address: Zip City Day Telephone: Fax Number: State Page 1 of 2 Fixture Type:; Qty °:.Fixture Type: " Qty . Fixture Type Qty Fixture Type: Qh' Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Valuation of Project (contractor's bid price): $ 3� \ GT \ Scope of Work (please provide detailed information): (`a %Q &t'A, \\f1 \Iht, `0 "Ot(1xv4 \\,\ c2{,5 c(4-c, ¶P,L)c) /111k,, Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW OR AUTHO ENT: Signature: `/ / a Print Name: Mailing Address: ./ (47/ -S'3' ) 6 51 Q:Wpplications\Fonns•Applications On Line\3 -2006 - Plumbing -Gas Piping Penni Application.doc Revised: 4-2006 bh Sewer: Day Telephone: VP //1 Date: /0/1 5/f? 1 s o4 State Zip Date Application Accepted: in i Date Application Expires: Staff Initials: 1 Page 2 of 2 RECEIPT NO: R07 -02273 Initials: JEM User ID: 1165 Payee: CAHILL PLUMBING AND HEATING INC. SET TRANSACTIONS: Set Member Amount Doc: RECSETS-06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: // ww.ci.tukwila.wa.us PG07 -279 88.00 PG07 -280 88.00 TOTAL: 176.00 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLUMBING - RES SET RECEIPT SET ID: 1017 SET NAME: CAHILL Payment Date: 10/17/2007 Total Payment: 176.00 Amount Payment Cash 176.00 TOTAL: 176.00 Account Code Current Pmts 000/322.100 TOTAL: t 176.00 176.00 Projec / T v Ke- ir/ oh r ._ Type of Inspection: �y '=" 715.-- ('c i-f G r a At H. 19 Address: Date Called: _./..— 7 // / /,, Special Instructions: Date Wanted: a.m. /U — 2 --77-7 (-TM' Requester: Phone No: _ G/25- - ?2 977 INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 proved per applicable codes. El Corrections required prior to approval. COMMENTS: Dk_ (Inspector: I oat7 6 - 7 $5$ REINSP ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 AMERICAN STATES INS CO 6411632 04/01/2006 Until Cancelled $12,000.00 04/03 /2006 Business Owner Information Name Role Effective Date Expiration Date CAHILL, HARRY PRESIDENT 04 /03/2006 CAHILL, RUSSELL VICE PRESIDENT 04 /03/2006 Look Up a Contractor, Electrin;an or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License CAHILPH942JC CAHILL PLUMBING & HEATING INC CONSTRUCTION CONTRACTOR 602598018 CORPORATION 23313 298TH AVE SE MAPLE VALLEY KING WA 98038 4255321977 ACTIVE GENERAL UNUSED 4/3/2006 4/3/2008 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= CAHILPH942JC 10/17/2007