HomeMy WebLinkAboutPermit PG07-284 - CRYSTAL RIDGE CONDOMINIUMS - FIRE DAMAGECRYSTAL RIDGE CONDOS
15325 SUNWOOD BL
PGO 7-284
Parcel No.: 1865200000
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
15325 SUNWOOD BL TUKW
CRYSTAL RIDGE CONDOMINIUM FIRE DAMAGE
15325 SUNWOOD BL , TUHWILA WA
CRYSTAL RIDGE HOME OWNER ASSOCIATION
224 NICKERSON ST , SEATTLE WA
Contact Person:
Name: MARCI MACIASZYK
Address: 211 185 PL SW , BOTHELL WA
City f Tukwila
Contractor:
Name: EMERALD CITY PLUMBING INC
Address: 211 185 PL SW , BOTHELL WA
Contractor License No: EMERACP964DJ
Value of Plumbing /Gas Piping:
Fees Collected:
DESCRIPTION OF WORK:
REPLACE PLUMBING FIXTURES IN 6 UNITS REMOVED TO REPAIR FIRE DAMAGED CONDO
UNITS. REPAIR WASTE AND VENT PIPING AS NEEDED IN WALLS OR ATTIC.
doc: UPC -10/06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
$20,000.00
$448.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
PLUMBING /GAS PIPING PERMIT
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND OUANTITY
Plumbing (cont.)
6 Building sewer and each trailer park sewer 0
0 Rain water system - per drain (inside bldg) 0
6 Water heater and/or vent 6
O Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
O Repair or alteration of water piping and/or water
0 treatment equipment 0
0 Repair or alteration of drainage or vent piping 1
6 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
0 Medical gas piping (6 +) inlets /outlets 0
6 Gas Piping
O Gas piping outlets (0-5) 0
6 Gas piping outlets (6 +) 0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 425 -776 -3344
Phone: 425 - 776 -3344
Expiration Date: 03/08/2008
PG07 -284
10/19/2007
04/16/2008
PG07 -284 Printed: 10 -19 -2007
Permit Center Authorized Signature:
The granting of this permit does not
const on or e performance of
Signature:
Print Name:
doc: UPC -10/06
City di
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
LJIL ?c,J
e to give authority to violate or cancel the provisions of any other state or local t aws regulating
authorized to sign and obtain this plumbing /gas piping permit. l
Date: l
tn,
Permit Number: PG07 -284
Issue Date: 10/19/2007
Permit Expires On: 04/16/2008
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG07 - 284 Printed: 10 -19 -2007
Parcel No.: 1865200000
Address:
Suite No:
Tenant:
1: ** *PLUMBING AND GAS PIPING * **
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
15325 SUNWOOD BL TUKW
PERMIT CONDITIONS
CRYSTAL RIDGE CONDOMINIUM FIRE DAMAGE
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
PG07 -284
ISSUED
10/19/2007
10/19/2007
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
PG07 -284 Printed: 10 -19 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Ilk A. k
Print Name: CVjr L.
doc: Cond -10/06
Date:
PG07 -284 Printed: 10 -19 -2007
Site Address:
Tenant Name:
Property Owners Name:
Mailing Address:
Name:
CITY OF TUKWIL
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Mailing Address: 07 / ( / S'S" ie
E -Mail Address:
Contact Person:
E -Mail Address:
7 )
Q: \Applications\Forms- Applications On Line\3 -2006 - Plumbing -Gas Piping Permit Application.doc
Revised: 42006
bh
Plumbing/Gas Permit No.
Project No.
(For o, fce use only
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
Contact Person:
E -Mail Address:
ENGINEER /OIL'- RECORD All plans must be wet stamped by Engineer of Record
/ Mng Co Assessor's Tax No.: / g e)DO a O
. Suite Number: Floor:
0 .... Yes Ea..No
New Tenant: 12
i
City
Cay
Contact Person: ,Z h, Pbeic f as Day Telephone:
E -Mail Address: //q / e Fax Number:
Contractor Registration Number:_,/` " &�/ )` -, / p �b VD, 1. Expiration Date:
State
Jeo
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Day Telephone: r- r744 -?j
v c X 2 Lc).A 9 POI
City State Zip
Fax Number: 25
PLUMBING / GAS PIPING CONTRACTOR INFORMATION
Company Name: FA /t, 71.Q Cl >2luu 61.7 i C , - , � ` (
Mailing Address: c (l I S - p J .8 ! ff `'1/A ° ( o Z
Stat Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of
Company Name:
Mailing Address:
State
State
Zip
City
Day Telephone:
Fax Number:
Company Name:
Mailing Address:
Zip
City
Day Telephone:
Fax Number:
Page 1 of 2
Fixture Type.'::
e
Future Type:
Qty
Fixture :T e'
YP
Fixture Type:
Qty
Bathtub or combination
bath/shower
r
(/f
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
.
Clothes washer, domestic
Floor drain
Sinks r
I ;;,
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
D
L avatory
(�)
Water Closet
I`
Buildin sewer or trailer
g
park sewer
Rain water sstem — er
Y P
drain (inside building)
�/
Water heater .} �� or
vent 4-
..
Lam'
Additional medical as
g
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Valuation of Project (contractor's bid price): $ / 00 a Ac
Scope of Work (please provide detailed information): ,• / �� � // ' Ilk 1 .4 !
C, 44- s -A /0 ./D 3 tea 2-o 3 3a � 3O3
Building Use (per Intl Building Code):
Occupancy (per Int'1 Building Code):
Utility Purveyor: Water:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE ST F WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDIN
Signature:
Print Name:
WN • OR AUTHO
i1//.
Mailing Address: �/ l / e
Date Application Accepted:
GENT:
i °/ 5`J
Q:\ Applications\Forms- Applications On Line \3 -2006 - Plumbing -Gas Piping Penni Application.doc
Revised: 4 -2006
bh
Sewer:
L� Day Telephone:
Pt j/
City
Date: /o - /g' - 'O
f1
Zip
State
Date Application Expires:
Staff Initials:
Page 2 of 2
1
Receipt No.: R07 -02296
Payee: EMERALD CITY PLUMBING INC
TRANSACTION LIST:
Type Method Description
ACCOUNT ITEM LIST:
Description
PLUMBING - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 1865200000 Permit Number: PG07 -284
Address: 15325 SUNWOOD BL TUKW Status: PENDING
Suite No: Applied Date: 10/19/2007
Applicant: CRYSTAL RIDGE CONDOMINIUM FIRE DAMAGE Issue Date:
Initials: WER Payment Date: 10/19/2007 02:48 PM
User ID: 1655 Balance: 30.00
Amount
Payment Check 5591 448.00
Account Code Current Pmts
000/322.100 448.00
Total: $448.00
Payment Amount: $448.00
22 9710
doc: Receiot -06 Printed: 10 -19 -2007
Pr CI ect: ,/�
r 1/5/ 4 /Ie/d9p.
Type of I \.
�.vrl J
Addre(s:
537 .S£/ivWOt/ &/
Date Called:
Special Instructions:
Date Wanted:
Requester:
Phone No:
VZS -7r.S— 9290
2--
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION '-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
PP /.71 i (1;n70 - b/_ i v
peci.r:
Date:
3 — /l- dfi
8.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
(Receipt No.:
'Date:
Proje
Type Inspectio :
Address:
Date Called:
Special Instructions:
Date Wanted: /
- ?
� J�
//
,�fii:
(F �
Reque�ster
Phone No:
INSPECTION NO.
- INSPECTION RECORD
Retain a copy with permit
�ERMIT N
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
COMMENTS:
In :
/-1 -t,€1 f 7 'f -t-( ..„
)431 -367
X Approved per applicable codes. El Corrections required prior to approval.
I Y/47
0 16.00 REINSPECTIO FEE REQU ED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
•
Pro'
(%vs /4 / i / < rf T
specin:
Type of I to
/�f / / A)
Address: 7 '
45 32s 5
/
Date Called:
Special Instructions:
Date Wanted:
a,
Requester:
Phone No:
a06-
7/
- //v
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670
El Approved per applicable codes.
n Corrections required prior to approval.
COMMENTS:
, J �
/6 ` 7(� � � -- / -./ •
Insp \ Date: /2i/t1-7
.00 REINSPECTION FE REQUIRED. P • r to inspection. fee must be
p aid at 6300 Southcenter B d.. Suite 10. Call the schedule reinspection.
eceipt No.: (Date:
03 -05 -2008
MARCI MACIASZYK
211 185 PL SW
BOTHELL WA 98012
RE: Permit No. PG07 -284
15325 SUNWOOD BL TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division.
Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the
Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does
allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests
must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from
being taken.
In the event you do not call for the above inspection and receive an extension prior to 04/21/2008 , your permit will become null and
void and any further work on the project will require a new permit application and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Xc:
Ter Marshall
it Technician
Permit File No. PG07 -284
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
License Information
License
EMERACP964DJ
Licensee Name
EMERALD CITY PLUMBING INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602305181
Ind. Ins. Account Id
SECRETARY
Business Type
CORPORATION
Address 1
211 185TH PL SW
Address 2
City
BOTHELL
County
SNOHOMISH
State
WA
Zip
980126219
Phone
4257763344
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
3/8/2004
Expiration Date
3/8/2008
Suspend Date
Separation Date
Parent Company
Previous License
EMERACP015B7
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
MACIASZYL, RORY T
PRESIDENT
03/11/2004
Bond
Amount
MACIASZYK, MARCI L
SECRETARY
03/11/2004
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
STATE
FARM
FIRE &
Until
Look Up a Contractor, Electrician or Plumber License Detail
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Page 1 of 2
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= EMERACP964DJ 10/19/2007