HomeMy WebLinkAboutPermit PG07-287 - WESTFIELD SOUTHCENTER MALL - HOT TOPICHOT TOPIC 2676 SOUTHCENTER MALL PGO7-287 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Cit,f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2676 SOUTHCENTER MALL TUKW HOT TOPIC 2676 SOUTHCENTER MALL , TUHWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: SHANNON HUNTER Address: 16435 N SCOTTSDALE RD, STE 195 , SCOTTSDALE AZ Contractor: Name: TIMBERWOLFF CONSTRUCTION INC Address: 1659 W ARROW RTE , UPLAND CA Contractor License No: TIMBECIO21DM Value of Plumbing /Gas Piping: Fees Collected: Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC /06 $5,000.00 $145.00 FIXTURE TYPE AND OUANTITY * *continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 480 998 -4200 Phone: 909 949 -0380 Expiration Date: 03/08/2010 DESCRIPTION OF WORK: TENANT IMPROVEMENT: NEW SINGLE ACCOMODATION HANDICAP ACCESSIBLE TOILET ROOM. PG07 -287 03/26/2008 09/22/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 1 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 1 Gas Piping 0 Gas piping outlets (0-5) 0 1 Gas piping outlets (6 +) 0 PG07 -287 Printed: 03 -26 -2008 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work • 0 be complied with, whether specified herein or not. construction The granting of this ,r - of p � s e to give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this plumbing/gas piping permit. r the ` IV 1 V Signature: Print Name: doc: UPC-10 /06 City oYTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I ecf. Permit Number: PGO7 -287 Issue Date: 03/26/2008 Permit Expires On: 09/22/2008 Date: ,) --tr) TJ Date: ,280,g ©ZJ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 - 287 Printed: 03 -26 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2676 SOUTHCENTER MALL TUKW HOT TOPIC 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -287 ISSUED 10/22/2007 03/26/2008 PG07 -287 Printed: 03 -26 -2008 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this e • oes not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the •erfo ' -- work. Date: 03- • uv PG07 -287 Printed: 03 -26 -2008 Name: 514441 'Len 44u.vt Mailing Address: E -Mail Address:Shan/ton. Au. W. t� / 1e . e,z-t Company Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tukwila.wa. us Contact Person: S $r. Peek - i It Pd Contractor Registration Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record gill t r t 0 AMA -2 Plumbing/Gas Permit No. Fkl- Public Works Permit No. Building Permit No. Mechanical Permit No. Project No. 1 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION / King Co Assessor's Tax No.: 040 0 3o y90o�3 Site Address: 33 5414.141, alb.-- / Suite Number: ,2125 Floor: a Tenant Name: /(OT TO PJ New Tenant: 0 Yes ❑ ..No Property Owners Name: We 54P e P Caney- A10bn Mailing Address: /f(dI Rud - II tk it or Las AQnsi /C4 C4- c� � State CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 148o-51 982- -e-/ took City State State Z Zip Zip Fax Number: — 99g 2 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: I ;Tel, »a Ff /TFG 7Zc.C.fr."— n II Mailing Address: /( '/3S A i. S'CoA4 / S+ /9s 4, iehe vs 7sy nn / City State Zip Contact Persor Awn jGQit1 AA Day Telephone: 'tee — f'^ 9'2e es E -Mail Address:_ 1 r" v'f'l . ACCl/(th42 e/ 4 caw- - Fax Number: y$O - r-- --7p -P- 3 Company Name: M PP Si n �Of1 f /74 zf f/ Ae■ Mailing Address: ('p 34` WCs /fa -4 74 -tQq y i-VeU/� n( 74's� / City State Zip Day Telephone: 07-00 S ' E -Mail Address: 01414 s--41 (A (�1� v /e4 7. eon Fax Number: ey7 /.T -' fiyy Q:1Appliations\Fonns- Applications On Line 13 -2006 - Permit Applation.doe Revised: 94006 bh Page 1 of 6 BUILDING PERMIT INFORS TION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1/57 O Existing Building v / Valuation: $ Scope of Work (please provide detailed information): COW S�rteC d/ /Uet*) 44 / Mel 1/ 4-y ,Le t Pmervaerne n41- /11C /1?k) s' Weir /.b "Px -res Pihiskes • O Will there be new rack storage? ❑ Yes Q: Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bb [A.. No If yes, a separate permit and plan] bmittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint : rea of the foundation of all structures, plus any decks over 18 inches • • d overhangs greater than 18 inches) *For an Accessory dwelling, ' ovide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor - a of accessory dwelling: *Provide docum tion that shows that the principal owner lives in one of the dwellings as his or her pn ' • residence. Number of Parking S • s Provided: Standard: Compact: Will there be a chan ' - in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers J Automatic Fire Alarm ❑ None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 0 ndicap: Other (specify) Page 2 of 6 • isting Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s Floor 2" Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORS TION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1/57 O Existing Building v / Valuation: $ Scope of Work (please provide detailed information): COW S�rteC d/ /Uet*) 44 / Mel 1/ 4-y ,Le t Pmervaerne n41- /11C /1?k) s' Weir /.b "Px -res Pihiskes • O Will there be new rack storage? ❑ Yes Q: Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bb [A.. No If yes, a separate permit and plan] bmittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint : rea of the foundation of all structures, plus any decks over 18 inches • • d overhangs greater than 18 inches) *For an Accessory dwelling, ' ovide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor - a of accessory dwelling: *Provide docum tion that shows that the principal owner lives in one of the dwellings as his or her pn ' • residence. Number of Parking S • s Provided: Standard: Compact: Will there be a chan ' - in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers J Automatic Fire Alarm ❑ None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 0 ndicap: Other (specify) Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower N Drinking fountain or water cooler (per head) \ \ Wash fountain N Gas piping outlets Bidet N Food -waste grinder, commercial \Receptor, indirect waste Clothes washer, domestic N .....,. Floor drain 1 Sinks 1 Dental unit, cuspidor Shower, single head trap 1_ Urinals Dishwasher, domestic, with independent drain ` Lavatory Water Closet ' Building sewer or trailer park sewer \ Rain water system — per drain (inside building) Repair or alteration of water piping and/or water treating equipment Water heater and/or vent Repair or alteration of drainage or vent piping 1 Additional medical gas inlets/outlets — six or more Medical gas piping system serving one to five inlets/outlets for specific gas Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 5000 Valuation of Gas Piping work (contractor's bid price): $ I Scope of Work (please provide detailed /� information): OP t� 5 IY!' (' /t r � d7IO6/G �1 e / e.5. iLk i I r i ronm?i Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: �c ?& , j I- Q:Wpplications\Forms- Applications On Linet3 -2006 - Permit Application.doc Revised: 9 -2006 bit Tu km) act Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: City State Zip S ewer : ( 1 1t t #,4 J 1 kwtl Q Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. S atu e: OWNER AUTHORIZE )J,j AGE s Print Name: S Mailing Address: aPu+oy Date: /0 —f6 `,07 Date Application Accepted: 10 12 Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh I Date Application Expires: Day Telephone: zip, City State ot-ll72d05 Staff Initials: Page 6 of 6 Receipt No.: R08 -00914 ACCOUNT ITEM LIST: Description PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.cidukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG07 -287 Address: 2676 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/22/2007 Applicant: HOT TOPIC Issue Date: Initials: WER Payment Date: 03/26/2008 01:21 PM User ID: 1655 Balance: $0.00 Payee: TIMBERWOLFF CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2198 118.00 Account Code Current Pmts 000/322.100 118.00 Total: $ 118.00 Payment Amount: $118.00 0445 03/26 $711 TOTAL 2054.34 doc: Receipt-06 Printed: 03 -26 -2008 Receipt No.: R07 -02306 Initials: JEM User ID: 1165 Payee: ADD: FITCH, INC. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: PG07 -287 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 10/22/2007 Applicant: HOT TOPIC Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 002431 27.00 Account Code Current Pmts 000/345.830 27.00 Total: $27.00 Payment Amount: $27.00 Payment Date: 10/22/2007 10:44 AM Balance: $118.00 D/27 710 TOTAL dnr.: RPreint -nR Printed: 1n-22-2M7 Project: i / 7C Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: J / , / � m Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PGD7 -)FA PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Y* 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: T/,q1 A Qk �n / ttzl 7 bac,I4k.) c i (Inspector: (Date: 7 $60.00,Q INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 4r6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: Approved per applicable codes. Corrections required prior to approval. /8 Project: HO % TD Pe Type of Inspection: finh9 / — /u i n6 Address: Q/376 m '9/I Date Called: Special Instructions: Date Wanted: a.m p.m. g -w Requester: Phone No: ��� - 5/ 512 - 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4 I� ‘ .7 K tyeefi4 for 7 fh t-- (°l /& 'Inspector: i Date: $60b0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: — Project: Pri/ — 10 Type of Inspection:, ) Pfn.A Al Address: ,441/ Date Called: Special Instructions: Date Wanted: a.m. p.m. 5---/zoAr Requester: Phone No: 'MY ,5"id .2-OAO P607 IN ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g- 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 Approved per applicable codes. INSPECTilON RECORD Retain a copy with permit COMMENTS: (V II o of ed" / () EJ Corrections required prior to approval. 0 $58.00 RERIECTION PEE REQUIRED. Prior to inspection. fee must be paid at 6 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Inspector: 'Date: 'Receipt No.: IDate: Project; 1 nT - 6 PIC' Type o nspection: r 6 Wes/ Address 2 1o7C fll A t Date Called: Special Instructions: Date Wanted: . . Requester: PWle '1e) -' i CD-Z6 () 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. 4 / CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Approved per applicable codes. Corrections required prior to approval. El $58.091 E FEE REQUIRED. Prior to inspection. fee must be paid t 300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: PERMIT NO. (206)431 -3670 03 -05 -2008 SHANNON HUNTER 16435 N SCOTTSDALE RD, STE 195 SCOTTSDALE AZ 85254 RE: Permit Application No. PG07 -287 2676 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 10/22/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 04/19/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/19/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become mill and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall Permit Technician xc: Permit File No. PG07 -287 pe City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 November 5, 2007 Shannon Hunter 16435 N Scottsdale Rd, Ste 195 Scottsdale AZ 85254 RE: CORRECTION LETTER #1 Plumbing/Gas Piping Application Number PG07 -287 Hot Topic — XXX Southcenter Mall, Ste 2125 Dear Mr. Hunter, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throuzh the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. encl xc: File No. PG07 -287 City of Tukwila Department of Community Development Steve Lancaster, Director P:\Perrnit Center\Correction Letters\2007\PG07 -287 Correction LIT #1.DOC wer Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: November 5, 2007 Project Name: Hot Topic Permit #: PG07 -287 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide for a drinking fountain on the plan and the plumbing fixture plan layout. (IBC 2903.4.1) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: PG07 -287 DATE. 12 -19 -07 PROJECT NAME: HOT TOPIC SITE ADDRESS: 2676 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: BuiI.O g ision Public Works DETERMINAT ON OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Approved U Approved with Conditions Notation: REVIEWER'S INITIALS: n ❑ Permit Coordinator ❑ DATE: DATE: Planning Division DUE DATE: 12-27-07 Not Applicable n ❑ No further Review Required DUE DATE: 01-24-08 Not Approved (attach comments) 17 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 ACTIVITY NUMBER: PG07 -287 DATE: 10 -22 -07 PROJECT NAME: HOT TOPICS SITE ADDRESS: XXX SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Issued Response to Correction Letter # DEPART ENTS: 0 ��� Buil�`1 ng v�'iso Public Works NA. No S Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ri Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Planning Division U Permit Coordinator n DUE DATE: 10-22-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: n DUE DATE: 11 -19-07 Approved ❑ Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 1:1 Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: P— E-0 7 ❑ Response to Incomplete Letter # ',II ,9Mt ® Response to Correction Letter # 1 -W ❑ Revision # after Permit is Issued DEC 19 2001 ❑ Revision requested by a City Building Inspector or Plans Examiner r a not i (;ENTER Project Name: Hot Topic Project Address: xxx Southcenter Mall, Ste 2125 Contact Person: " "'L" fait 1)t4 t1,le1 Phone Number: <fro -9 Summar of Revision: p 1 t-t4 / els a kei ii, .4 /e? cfj 7111, 4t -�4 gAtm t 1 ,� Te T ('Y P- l � 5 '�� °',, 1 See_ su04I4 -y stul w f pic Sheet Number(s): I 1 7 Id-k 3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on City of Tukwila \applications \forms- applications on line \revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: PG07 -287 Steven M. Mullet, Mayor Steve Lancaster, Director License Information License TIMBECIO21DM Licensee Name TIMBERWOLFF CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601859639 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 1659 W ARROW RTE Address 2 City UPLAND County OUT OF STATE State CA Zip 91786 Phone 9099490380 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/14/1998 Expiration Date 3/8/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WOLFF, MICHAEL EDWARD PRESIDENT 03/14/1998 WOLFF, MONIQUE M SECRETARY 03/14/1998 WOLFF, GLADYS VICE PRESIDENT 03/14/1998 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Account Effective Expiration Cancel Impaired Bond Received https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TIMBECIO21 DM 03/26/2008 T TITLE SHEET Al FLOOR PLAN A2 REFLECTED CEILING PLAN A3 INTERIOR ELEVATIONS A3A INTERIOR ELEVATIONS A4 FINISH AND RESPONSIBILITY SCHEDULE A5 STOREFRONT ELEVATION & ENLARGED PLAN A5A STOREFRONT SECTIONS A6 FIXTURE / FLOOR FINISH PLAN A7 SECTIONS AND DETAILS AS SECTIONS AND DETAILS MI MECHANICAL PLAN M2 MECHANICAL NOTES AND SPECIFICATIONS P1 PLUMBING PLAN, NOTES AND SPECIFICATIONS El ELECTRICAL POWER PLAN E2 ELECTRICAL LIGHTING PLAN E3 ELECTRICAL SCHEDULES, DIAGRAMS AND NOTES RECEIVED CITY OF TUKWILA DEC 1 9 2007 CORRFC;TInM PERMIT CENT> LTR# 1 - - - 6 01_, n PROTOTYPE RENDERING - ACTUAL STORE MAY VARY PROJECT LOCATION • • .....7 ANS.7. VICINITY MAP TUKWILA, WASHINGTON 1/4 l"at .:1 �.;. ''-a (Mloide� . r . • z\l* SPACE # 2125 LEVEL2OF2 NORDSMOM I IMF 111 ::: 0 IF- DAR IV ''1 JCPenney KEY PLAN WESTFIELD SOUTHCENTER MALL (FLOOR 2 OF 2) 1. PROJECT NAME _ HOT TOPIC 2. PROJECT DESCRIPTION:..... ... CLOTHING SALES (RETAIL) 3. PROJECT LOCATION : ..... _ . WESTFIELD SOUTHCENTER MALI. 633 SOUTHCENTER MALL SPACE NO. 2125 TUKWILA, WASHINGTON 98188 HOT TOPIC dba TORRID 18305 E. SAN JOSE AVENUE CITY OF INDUSTRY, CALIFORNIA 91748 (626) 839 -4682 CHRIS LANCASTER clancasterghottopic.com WESTFIELD CORPORATION 11601 WILSHIRE BOULEVARD — 11TH FLOOR LOS ANGELES, CALIFORNIA 90025 PROJECT MANAGER: JOSH KIMMEL PHONE: (310) 893 -4761 6. TENANT'S ARCHITECT: ....... ..... AAD:fltch dba FITCH 16435 NORTH SCOTTSDALE ROAD, SUITE #195 SCOTTSDALE, ARIZONA 85254 CONTACT: RON HEDLUND PHONE: (480) 998-4200 FAX: (480) 998 -7223 E —MAIL: ron.hedlundQfitch.com 7. GOVERNING CODES: _ _ ...... .. ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, THE REQUIREMENTS OF THE FOLLOWING: AND ANY OTHER STATE AND LOCAL CODES HAVING JURISDICTION. 4. TENANT: 5. LANDLORD: 12. 13. 14. 8. CONSTRUCTION TYPE 9. OCCUPANCY: 10. GROSS LEASED PREMISES: .......... .._. 11. OCCUPANT LOAD: _ ...._..__....__..�..._ „... EXIT REQUIREMENTS: ._� _...._....__ EXIT ILLUMINATION: MUNICIPAL REVIEW: _ -- 16. FIRE SPRINKLERS: WESTFIELD SOUTHCENTER BUILDING: MECHANICAL: PLUMBING: ELECTRICAL: ENERGY: FIRE: HANDICAP: 2 —B M (MERCANTILE) 2,025 SQ. FT. PROJECT DATA 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL PLUMBING CODE 2005 NATIONAL ELECTRIC CODE WASHINGTON ENERGY CODE 2006 INTERNATIONAL FIRE CODE CURRENT ADA 633 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 PERMIT FOR: V Mecr►aniCal E lectrical 0 Plumbing 0 Gas Piping City of Tukwila BUILDING DIVISION TOTAL NUMBER OF OCCUPANTS = 58 TOTAL NUMBER OF EMPLOYEES AT ONE TIME = 3 PUBLIC AREA: 1,653 S.F. _ 30 = 56 NON PUBLIC AREA: 372 S.F. _ 300 = 2 TWO (2) EXITS REQ., TWO (2) EXITS PROVIDED EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED AS SHOWN ON SHEET E2. CITY OF TUKWILA BUILDING DEPARTMENT 6300 SOUTHCENTER BOULEVARD, SUITE #100 TUKWILA, WASHINGTON 98188 CONTACT: ALAN JOHANNESSEN PHONE: (206) 431 -3670 15. MISCELLANEOUS NOTES:.. _ TENANT'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL REPORT ALL DISCREPANCIES TO TENANT'S ARCHITECT. TENANT'S GENERAL CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE, ETC., AS SET FORTH BY THE LANDLORD. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS EXISTING WITHIN THIS SPACE. THE CONTRACTOR SHALL REWORK AND MODIFY FOR NEW ROOM LAYOUT AND CEILING HEIGHTS IN CONFORMANCE WITH N.F.P.A. 13 STANDARDS AND LOCAL CODES & REGULATIONS. ALL WORK SHALL BE DONE BY A QUALIFIED SPRINKLER CONTRACTOR WHO SHALL DESIGN AND PREPARE SHOP DRAWINGS AND SUBMIT THEM TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SPRINKLER CONTRACTOR SHALL BE LANDLORD APPROVED. HEADS IN CEILING TILES TO BE CENTERED IN TILES WHEN IN A PUBLIC AREA. NOTE FIRE SPRINKLER DRAWINGS AND HYDRAULIC CALCULATIONS AND CALCULATIONS SHALL BE SUBMITTED BY THE LICENSED FIRE SPRINKLER CONTRACTOR TO THE GOVERNING MUNICIPALITY FOR APPROVAL PRIOR TO ANY WORK BEING PERFORMED. MALL SPACE NO. 2125 INDEX OF DRAWINGS FILE COPY Pelt Nos Plan reVieW oproval Is skied to anus and omissions. Approval of construction documents does not authorize the violation s,_fot . y T. . : or�. Receipt of a , I!. i. i. I.. lf BY City of Tukwila BUILDING DIVISION 4 1 PE'I ;ONS Na Chap be s shall mado to the scope Of work without prior approval of Tukwila Building Division. NOM Fusions will require a new plan submittal and may include additional plan review fees. 0186 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. SCALE: PROJECT No.: z 0 L NONE DRAWN BY: covey.. GROFF HOT- O1 -O24 ARAI In 1 cu N I In N © 44 DATE: October 15th, 2001 SHEET: 0 2 u :UEC 7 g7 Lel un 0o fa 0 .60 4 r E ` CI a g T 1 of l"1 KEY SYM. DESCRIPTION TOP BOT. . � ; . :.. G WALL: -5/5" X 20ga. METAL STOPS (ICSO ER* 4143) 6 24" 0... W/ 5/8" TYPE X GYP BD ONE SIDE TO 6" ABOVE EILIN6 PREPARE FOR FINISH PER THE INT. ELEVS. Alek AS * FULL HEIGHT PARTITION TO DECK: 5-5/8" X 20ga. METAL STUDS (IC150 ER#4143) 0 16" O.G. TO UNDERSIDE OF STRUCTURE ABV. W/ 5/8" TYPE X GYP BD BOTH SIDES TO HIGHEST ADJ. CEILING. (OR DECK) PREPARE POR FINISH PER THE INT. ELEVATIONS 15 AM w=§3=K:=E:=1 I-HOUR RATED '°i8 IV 0 TYP. INTERIOR PARTITION: 3 -5/8" X ISga. METAL STUDS 6 16" D.G. W/ 5/8" TYPE X GYP BD BOTH SIDES TO HIGHEST ADJACENT .EILIN6. PREPARE POR FINISH PER THE INTERIOR ELEVATIONS. NOTE: AT WALL THERE MUST BE CLEAR /\ SPACE FROM DECK TO GYP. BP. POR HVAG AI AlEk IV ‘17 O LOW PARTITION: 2 I /2" X 20ga. METAL STUDS 0 16" O.C. TO 54" A.F.F. VERIFY EXTERIOR FINISH PER INTERIOR ELEVATIONS. 0 MI 0 PLATFORM WALL: 3 -5/5" X ISga. METAL STUDS 6 16" O.G. W/ 5/8" TYPE X GYP SD BOTH SIDES TO HIGHEST ADJACENT CEILING.. PREPARE FOR FINISH PER THE INTERIOR ELEVATIONS. SEE TYPICAL SECTION ON THIS SHEET. GI ) <> 1 —HR VESTIBULE PARTITION: NOTES: I-HR FIRE RATED. UL DESIGN *U465 3 -5/8" X ISga. METAL STUDS 0 16" O.G. W/ 5/8" TYPE 'X' GYP BD TO CEILING. PREPARE FOR FINISH PER THE INTERIOR ELEVATIONS. 4 ' 7 ;W>Y •• D I H.G. DRINKING FOUNTAIN 5' -0" GLR. 11 31.11 GLR. r /..d AM" IS" 3'-0" _ Q I �'� � r 0I 1 I' - L _i__� -� X 11 I 'll ��irrriiriAMI~�1 /2 1, 7 WA i7r�r.5>✓l iT Il / / / / / / / / / / /% r /AU /AiAiZ.W i1"ri 121M./AMII; :41 Ar/ _ w ' . Z.�r isi7i��i�i i i - i�i�i 1/2" TEMP. S.F. GLAZING IN METAL FRAME SYSTEM LEASE -LINE PR. WOOD AND GLASS DOORS. SEE SCHEDULE LEASE -LINE 1/2" TEMP. S.F. GLAZING IN METAL FRAME SYSTEM ILLUMINATED EXIT SIGN ABOVE. SEE SHEET E2. NEW EXIT SERVICE DOOR. SEE DOOR SCHEDULE ELECT. ROOM ELECTRICAL EQUIPMENT. SEE ELEC. DINGS. EXISTING DEMISING PARTITION TENANT SHALL PATCH AND REPAIR EXISTING DEMISING WALLS AS NECESSARY AT TENANT'S EXPENSE SURFACE MTP. STANDARDS W/ SHELVING 4 HANGRODS IN STOCKROOM. SEE TYPICAL ELEVATIONS 1•.75' -=rr +:r- rcmil, ti "M�= Ftxa=- NOTE: WALLS AND DECK TO SUPPORT ALL EQUIPMENT AND SERVICE PERSONNEL_ HALL WAY I0' -5" ILLUMINATED EXIT SIGN ABOVE. SEE SHEET E2. ALCOVE I' -6" 1' -6" EXISTING DEMISING PARTITION TENANT SHALL PATCH AND REPAIR EXISTING DEMISING WALLS AS NECESSARY AT TENANT'S EXPENSE H.G. TOILET ROOMS W/ NEW H.G. FIXTURES 4 ACCESSORIES 3I' -I" NOTE: WHEN EXTENDING MALL TILE TO TENANT'S STOREFRONT BASEOR VESTIBULES TILES MUST BE FULL TILE. IF TILE IS GUT IT MUST BE REMOVED AND REPLACED WITH FULL TL!~. 61' -O" 2 3 CASH/ WRAP MALL CORRIDOR SALES AREA 21' -E EXISTING CONCRETE FLOOR SURFACE PREPARE FOR INSTALLATION OF NEW FLOORING MATERIALS AS INDICATED IN THESE PLANS. SEE SHEET A4 FOR ADD. FLOOR PREPARATION NOTES. ADJACENT TENANT 3/4" BLK. METAL REVEAL EXISTING NEUTRAL PIER LINE OF SOFFIT ABOVE PROVIDE SIGNS OVER DOORS STATING: 'THIS DOOR TO REMAIN UNLOCKED DURNG BUSINESS HOURS " LETTERS TO T' HIGH ON A CONTRASTING BACKGROUM. 2" WIDE X 1 1/4" DEEP DEPRESSION FOR SENSORMATIC GRID. b.C. TO SUPPLY 1/2" PVC CONDUIT AND GOORD. W/ SYSTEM INSTALLER. GOORD. FLOOR WORK W/ MALL OPERATIONS. =n �;11 X11 A 1 > > -. ��. i.r..i 1r,_ I ri ■:isi V,awi.Ii,wri�r i i i ii isi. i.Mi∎i ∎9wwi i. i.� rPiAi. i ,ii.AWiAiw►i BA s N l,I M M FAUX WINDOW AND FRAME. SEE SHEET A5. XISTIN6 NEUTRAL PIER EXISTING DEMISING PARTITION TENANT SHALL PATCH AND REPAIR EXISTING DEMISING WALLS AS NECESSARY AT TENANT'S EXPENSE in n IN TOILET ROOMS: INSTALL WATERPROOF MEMBRANE UNDER FINISH FLOOR AND 4" UP WALLS NOTE: SECOND LEVEL TENANT'S MUST HAVE WATERPROOF MEMBRANE UNDER RESTROOM / WET AREA FLOOR FINISHES. 11" -- EXISTING DEMISING PARTITION 1-HOUR RAID WALL AND CEILING.: 3 -5/8" x 20ga. METAL JOISTS ® 16" D.G. W/ 5/5" TYPE 'X' GYP. BD. APPLIED VERTICALLY W/ I" LONG #6 DRYWALL SCREWS TO EACH STUD. SCREWS ARE b" O.G. AROUND PERIMETER AND 12" D.G. ON INTERMEDIATE STUD. WALLBOARD MAY BE APPLIED HORIZONTALLY TO 3 -5/8" METAL STUDS WHEN THE JOINTS ARE STAGGERED WITH THOSE ON THE OPPOSITE SIDE. SCREWS FOR THE HORIZ. APPLICATION SHALL BE S" O.G. AT VERT, EDGES AND 12" O.G. AT INTERMEDIATE STUDS. 3 -5/6" X 209a. METAL STUD JOISTS. 616" O.G. 1-HOUR VESTIBULE 11-HR. VESTIBULE EXISTING CONCRETE SLAB WALL SECTION FLOOR PLAN 11 - 6-5/5" x 20ga. METAL STUD FRAMING TO CEILING ABOVE STOCK ROOM CONT. 20 GA. BOTTOM TRACK w/ 'HILT!' ON OR DS SHOT PIN INTO SLAB AT 24" O.G. (I.G.B.O. #2388) SCALE: I "= I' -O" EXISTING DEMISING PARTITION I -HOUR RATED WALL AND CEILING.: 3 -5/8" x 20ga. METAL JOISTS ® 16" O.G. W/ 518" TYPE 'X' GYP. BD. APPLIED VERTICALLY W/ I" LONG #6 DRYWALL SCREWS TO EACH STUD. SCREWS ARE 8" O.G. AROUND PERIMETER AND 12" O.G. ON INTERMEDIATE STUD. WALLBOARD MAY BE APPLIED HORIZONTALLY TO 3 -5 /8" METAL 6TUD5 WHEN THE JOINTS ARE STAGGERED WITH THOSE ON THE OPPOSITE SIDE. SCREWS FOR THE HORIZ. APPLICATION SHALL BE 8" O.G. AT VERT, EDGES AND 12" O.G. AT INTERMEDIATE STUDS. 6" X 20ga. METAL STUD JOISTS. 616" O.G. I -HR. RATED DOOR AND FRAME. SEE SHEET Al 1-HR. VESTIBULE EXISTING CONCRETE SLAB WALL SECTION 1 -HOUR VESTIBULE • HALLWAY SCALE: 1"=1 83' -1" - LEASED DIMENSION NO GYP. REG.„- TOILET ROOM BASE PER PLANS WALL SECTION TOILET ROOM PLATFORM 3 PLATFORM DESIGNED FOR 125LB. / SO. FT. 5/8" TYPE "X" GYP. BD. TAPE, SAND, PREPARE FOR FINISH PER ELEVATIONS. USE W.P. 'GREEN' GYP. BD. IN TOILET RM. NOT ANY WOOD USED IN CONSTRUCTION MUST BE FIRE TREATED. 3 -5/5" or 6" x ISga. METAL STUDS @ 16" O.G. SEE PLAN EXISTING CONCRETE SLAB CHICKEN WIRE TO DECK ABOVE ATTACH WALL TO WALLS AT EACH END FOR LATERAL SUPPRORr. 8 -5/8" x I Sga. MTL. STUD BACKDROP PARTITION STUDS 24" O.G. W/ 5 /8" TYPE 'x' 6TP BD. TO 46" ABOVE TOP OF DECK. SCALE: I=I-c'" 3 -5/6" X 20ga. METAL STUD BRACING BACK TO NEAREST ADJACENT WALL AS REQUIRED. FIRE TREATED PLYWOOD OVER 5/6" TYPE 'X' GYP. BD. SCREW THRU TO STUDS W/ 2 -I/2" LONG SELF TAPPING COUNTERSUNK SCREWS AT 6" O.G. AT BOARD EDGES, 4 12" O.G. FOR THE FIELD —8" X ISga. METAL STUD JOISTS. @l6" O.G. ALIGN EACH JOIST DIRECTLY OVER STUD IN WALL. I -1/2" x I -I/2" x 20ga. METAL 'L' AT EDGE OF PLATFORM PERIMETER SCREW THROUGH TOP INTO PLYWOOD _ 8' -0"* CONT. 3 - /8" x 15ga. TOP TRACK - 5-5 /5" x 20 ga. METAL STUDS @ 16" D.C. TO FRAMING ABOVE. 'STOCK ROOM CONT. 20 A. BOTTOM TRACK w/ 'HILT!' DN OR DS SHOT PIN INTO SLAB AT 24" O.G. (I.G.B.O. #2388) 54" BREAK -METAL GAP BY OWNER. (F.O.I...) SLATWALL 2 -1/2" x 20 ga. METAL STUDS 16" O.G. TO FRAMING ABOVE. METAL CAP DTL. SCALE: 3 "= 1' -0" 6' -O" SCALE: 1/4" = 1' -0" NOTE: SEE ENLARGED STOREFRONT PLAN, SHEET A. FOR COMPLETE STOREFRONT DIMENSIONING WALL TYPE LEGEND RECEIVED CITY OF TUKWILA DEC 19 2007 Vti\! L ER LANDLORD NOTES: I. LANDLORD TO PROVIDE 6" METAL STUD FRAMING FOR ALL DEMISING WALLS. TENANT TO INSTALL 5/8" TYPE 'X' GYP. BD. ON TENANT'S SIDE OF DEMISING WALL. TENANT MUST MAINTAIN A 6" MIN. CLEAR OPEN HEIGHT ABOVE COMMON TENANT DEMISING WALLS AND BELOW STRUCTURE. 2. TENANT SHALL PROPERLY SEAL ALL PENETRATIONS TO COMPLY WITH GODS REQUIREMENTS. FIRE RATED DOOR ASSEMBLY SHALL BE MAINTAINED. ALL. MECHANICAL, PLUMBING AND ELECTRICAL DEVICES PENETRATING FLOOR SHALL SE FIRE RATED. 3. TENANT G.G. TO GET APPROVAL AND GORING REQUIREMENTS ON UPPER LEVEL PRIOR TO ANY WORK. 4. NO PEDESTAL SECURITY SYSTEMS WILL BE ALLOWED. UNDER FLOOR TYPE IS ACCEPTABLE. 5. AT RESTROOMS: INSTALL CERAMIC TILE FLOORING OVER WATERFROOFING MEMBRANE WHICH IS TO RUN UP WALLS A MINIMUM OF 4 ". INSTALL A LANDLORD APPROVED LATEX RUBBER WATERPROOFING MATERIAL UNDER THE FLOOR FINISH. THE MEMBRANE SHALL BE MANUFACTURER'S 2 PART FORMULA GONSISITINO OF LIQUID LATEX RUBBER AND POWDER FOR TROWEL APPLICATION WITH GLASS FIBER PABRIG REINFORCEMENT (LATIGRETE 1235 OR SUMMITVILLE 5 -1000) INSTALL A WATER TIGHT POOR THRESHOLD. 6. REAR EXIT DOOR CANNOT SWING INTO CORRIDOR AND MUST BE ENCLOSED WITHIN AN ALCOVE. IF CORRIDOR IS RAID, ALCOVE AND DOOR MUST BE RATED TO MATCH. ALCOVE TO HAVE Q'-O" A.F.F. GYP. BD. .EILIN6 WITH RECESSED LIGHTING. FINISH IS TD MATCH CORRIDOR. INSTALL A DOORBELL LOCATED 3' -6" A.P.F. 1. REAR DOOR SIONAGE: TENANT'S NAME AND SPACE NUMBER INSTALL 2" HIGH, DIE GUT, VANDAL PROOF, WHITE HELVETICA BLOCK STYLE LETTERS ON A RED BACKGROUND MOUNTED AT 5' -O" A.F.F. CENTERED ON DOOR. 8. INSTALL 4 "X4 "X4' - STAINLESS STEEL; 10 ga. STAINLESS STEEL CORNER GUARDS ON OUTSIDE CORNERS OF ALCOVE. SCALE: 0186 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result In cessation of construction, building seizure, and /or monetary liability. co co CI i n 16C — 1 crb. r N u wing C CI via a 03 fi= V nil 0 CL en n 0 I as cJ P 1/4"z-T-0" DRAWN BY: .COVEY 6ROFF PROJECT No.: HOT -01 -024 Owl n RJ M z 0 w 0 c1 DATE: October 15th, 2001 SHEET: u1 5 el P 11 m :o an be u c O N of u Z g a CC 0 0 u. AEC ' 0 N a V o • Al 2 of I'l F+1 480 998 7223 CONSULTING ENGINEER PER LANDLORD PER B. DEPT. PER OWNER SIRE PROTECTION LEGEND 8 e 8 0 & & z 70 rn z 7i ra EXISTING UPRIGHT TYPE SPRINKLER TO REMAIN RELOCATED UPRIGHT TYPE SPRINKLER NEW UPRIGHT TYPE SPRINKLER CONGEALED EXISTING TO REMAIN CONGEALED RELOCATED CONGEALED TYPE SPRINKLER PROVIDE AND INSTALL 16" cr9 INSULATED MEDIUM PRESSURE METAL SPIRAL DUCTWORK FROM TAP TO VAV BOX. VERIFY EXACT LOCATION N FIELD. EXISTING LANDLORD SUPPLY AIR DUCT. SEMI- RECESSE _Z -11 ( MECHANICAL PLAN (NEW) 6" TOILET EXAHUST AIR DUCT TO LANDLORD COMMON EXHAUST DUCT STUBS. VERIFY EXACT LOCATION IN FIELD. LANDLORD NOTES TENANT SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIRFLOW BACK TO LANDLORD AIR CONDITIONING UNIT. LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -IS. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL. ALL BRANCH PIPING AND SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO D PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE EASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZE SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -I3. AA 250 ON ON 14'10 1 1; r J 1. -- 11 WPM r I 11 L A _ ( I ) AA 250 PAINT DIFFUSERS SILVER (TYP. 8) J "0 250 8 •o fi I 1 NOTES BY SYMBOL 0 PROVIDE AND INSTALL NEW VAV BOX AS SPECIFIED ON SHEET M2. O RELOCATE PROGRAMMABLE THERMOSTAT. PROVIDE WITH CLEAR PLASTIC LOCKING COVER. COORDINATE EXACT LOCATION WITH ARCHITECT'S I NTERIOR ELEVATIONS. ON ON 5 11 co • n L_ _,__. PLAN MARK AIR DEVICE SCHEDULE MANU. -. MODEL FACE SIZE NECK SIZE TITUS - TMRA 22 "0 SEE PLAN TYPE ROUND MATERIAL NOTES STEEL TITUS - TDG • TITUS - TDG TITUS - BOR 24x24 12>d2 24x24 SEE PLAN SEE PLAN SQUARE SQUARE SQUARE STEEL STEEL STEEL • �F I 3. 4 . GENERAL NOTES BALANCE SYSTEM WITH GPMS SHOWN. SCALE: I/4" = 1' - 0" 2. COORDINATE DUCT AND DIFFUSER MOUNTING HEIGHTS WITH CEILING LAYOUT. T.G.G. SHALL MAINTAIN THE INTEGRITY OF THE HVAC CONTROLS CONNECTION TO THE MALL ENERGY MANAGEMENT SYSTEM.. ALL DUCTWORK AND SUPPLY GRILLES ARE EXPOSED BELOW GRID CEILING IN SALES AREA. COORDINATE MOUNTING HEIGHTS WITH ARCHITECTURAL PLANS. 21 4- RECEIVED CITY OF TUKWILA DEC 1 9 2007 F'ti�ivil i GEN I ER G N t O 15 al ■ 0w� u�C ■ a +I CD Z ( .9 ci rei VI in to fZ.M COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. as DATE: October ISth, 200'7 SHEET: SCALE: c o W e w -a0 zY� W aco as z�W�v Z — FN• 1— 0 ZZa� O �,a x U me . DRAWN BY: PROJECT Na.: IIIIII iN To 00 2 03 vt z 0 1 1 /4 "= 1'--0" 1/111111 I I � [III II DPE HOT -O -024 Ln N Lfl to co C 0 N - 0 q) Z m L t to ct g g el to a; 3 E IU +� 15 D C 1= O 0 nzt E O O 61 t u 12 of 1"1 F+1 480 998 7223 CONSULTING ENGINEER SINGLE DOUBLE ABBR. DESCRIPTION • RECTANGULAR DUCT • ROUND DUCT C C • 45 DEG. TAP: USE AT BRANCH DUCTS ONLY 4 + e • DUCT SPLIT W /DAMPER: USE AT ELBOWS AND TEES: PROPORTION DUCT AREAS BY CFM'S + • CURVED ELBOW -MIN. RADIUS R: 1.5 WIDTH • 90 DEG. ELBOW WITH SINGLE RADIUS TURNING VANES iMMEMI ir • FLEXIBLE DUCT CONNECTION 111111 --4 a( FD FIRE DAMPER 7 1 / )f r Jr BD BALANCING DAMPER (USE O.B.D. UNLESS NOTED OTHERWISE) I Q i- NEW TO EXISTING CONNECTION ) j r • SPIN -IN FLEX DUCT TAKE -OFF W /DAMPER 1 , 5 lir • SA SUPPLY AIR • X EXH EXHAUST AIR RECEIVED CITY OF TUK`n I A • / RA RETURN AIR nFr. 1 q 7nni • R L REL RELIEF AIR pE 1`/lIT HN'fl =R C . • . OSA OUTSIDE AIR • 0 X T THERMOSTAT X: UNIT OR ZONE NUMBER • OT X T THERMOSTAT W /SHERWOOD GUARD 1 MANUFACTURER TITUS MODEL # ATQS7 --16" CFM 2400 MIN. CFM SETTING 1800 MAX. CFM SETTING 3100 WEIGHT REF. 1,2,3 3. 3 KW 208V 3PH ELECTRICAL HEAT STRIP MARK VAV -1 MARK EF -1 VARIABLE AIR VOLUME BOX NEW EXHAUST FAN SCHEDULE r�r Ck; NOTES P - .v I a 1 1. MIN SET POINT AT 300. SPIRAL ROUND S.A. DUCTWORK ABOVE CEILING. SEE PLAN FOR DUCT SIZE. MANUAL BALANCING DAMPER. TRANSITION S.A. DUCTWORK TO 10"O TO FIT 10"0 NECK OF DIFFUSER. NOTE: PRIOR TO CONSTRUCTION/ BID THE CONTRACTOR SHALL VISIT THIS SITE AND FIELD VERIFY THE EXISTING LOCATIONS AND SIZES OF ANY LANDLORD PROVIDED, OR EXISTING, OUTSIDE AIR INTAKES THROUGH ROOF, LANDLORD PROVIDED CHILLED /HOT WATER PIPING MAINS, TOILET EXHAUST MAINS, OUTSIDE AIR DUCTWORK, CONDENSATE LINE MAINS, ETC. THE CONTRACTOR SHALL FIELD VERIFY ANY/ CONDITIONS WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON THESE PLANS. NOTIFY ARCHITECT IMMEDIATELY. , : u�l�:Sti I „ i:iiL ?,i?irziv; : ∎ ∎rt • ,.' t; f3 ONTROLS AREA SERVED TOILET ROOM MANUFACTURER BROAN MODEL 684 CFM 80 E.S.P. ( "W.C.) 0.125 MOTOR HP FRAC. v /PH 120/1 BAROMETRIC DAMPER YES ES) 12' -0" A.F.F. S.A. DIFFUSER WITH 10 "o NECK & 22 "� TOTAL OUTSIDE DIAMETER. BALANCE TO CFM NOTED ON PLAN. DRIVE DIRECT N.T.S. ROUND SUPPLY AIR DIFFUSER DETAIL yr LOAD TABULATION + COOLING OA DB COOLING IA DB + HEATING OA + ROOF U- FACTOR -h LIGHT DIVERS ** VAV MIN AIR + LTS - SURFACE + %LTS- SURFACE + WALL AREA + %ROOF TO SPACE PEOPLE SENS HEAT VENTILATION ROOF LOAD LTS- SURFACE LTS - RECESSED MISC LOAD WALL LOAD HOT TOPIC Westfield Southcenter Mall Tukwila, WA 2025SQUARE FEET ASHRAE DESIGN CONDITIONS 84 76 21 0.000 1.2 270 6868 100 0 70 250 SENSIBLE HEAT GAIN VENTILATION ROOF LOAD WALL LOAD TOTAL SENSIBLE 37147 - TOTAL COOLING LOAD SENS/TOTAL RATIO NOMINAL CFM (15 DEG F DIFF) + SUPPLY AIR TEMP TEMPERATURE DIFFERENCE COOLING LOAD SUMMARY 0 HEATING LOAD SUMMARY 0 0 0 TOTAL HEATING LOAD NOMINAL KW ELEC HEAT MINIMUM KW ELEC HEAT COOLING OA WB COOLING IA WB HEATING IA LTS- RECESSED %LTS- RECESSED MISC. WATTS SQ FT /PERSON NO OF PEOPLE WALL U- FACTOR 68 + 63 72 196 + 70 + 500 + 75 + 27 0.20 + PEOPLE LATENT 200 SENSIBLE HEAT GAIN PEOPLE 6750 PEOPLE 0 VENTILATION 0 70% TO SPACE 28129 100% TO SPACE 562 70% TO SPACE 1707 LATENT HEAT GAIN 5400 0 TOTAL LATENT 42547BTUH 87 % 1876CFM 58 DEG F 18 DEG F LATENT HEAT GAIN VENTILATION 0 TOTAL SENSIBLE 0 TOTAL LATENT 0 (BASED ON 20 DEG F RISE @ VAV MIN AIR) LANDLORD NOTES: LANDLORD HAS PROVIDED A PROPRIETARY D.D.C. CONTROL SYSTEM FOR V.A.V. CONTROL-TENANT TO PROVIDE 4 " CONDUIT AND SHIELDED CABLE FROM LANDLORD'S JUNCTION BOX TO V.A.V. BOX(ES) AND THERMOSTAT(S) -FINAL WIRING CONNECTIONS TO ALL DEVICES BY LANDLORD AT TENANT'S EXPENSE -ALL AS PER PROJECT STANDARD DETAILS. T.G.C. SHALL ENGAGE A SEPERATE TEMPERATURE CONTROL CONTRACTOR FOR FINAL SET -UP OF SYSTEM(S) OPERATIONS AND AIR BALANCING. GIVE ONE COPY OF BALANCE REPORT TO LANDLORD'S BUILDING ENGINEER. T.G.C. MUST USE LANDLORD APPROVED CONTRACTOR. SET VAV BOX TO DELIVER 2,400 CFM MAX. 5400 0.93 CFM /SQ FT 21 BTUH /SQ FT 3.5 TONS 571 SQ FT/TON 0 BTUH 0 KW 2 KW 12:00:00 AM CNTYVAV.WKS * SA TEMP AT UNIT AT SPACE ON DESIGN DAY ** SPECIAL ALLOWANCE FACTOR PER ASHRAE (TABLE 15 /CHAPTER 26) 3.5 W /SQ FT VAV NOTES 1. USE ONLY LANDLORD SPECIFICATION VAV CONTROLS FOR THIS PROJECT. REFER TO TEMPERATURE CONTROL NOTES THIS SHEET FOR ADDITIONAL INFORMATION ON PROGRAMMING AND FINAL WIRING CONNECTIONS TO THE LANDLORD'S SYSTEM. 2. UTILIZE ONLY RIGID DUCTWORK UPSTREAM OF THE VAV BOX. PROVIDE FOUR EQUIVALENT DUCT DIAMETERS OF STRAIGHT DUCTWORK DIRECTLY UPSTREAM OF THE VAV BOX INLETS. 3. UTILITIES ARE AVAILABLE AT DESIGNATED LOCATIONS WHICH MAY NOT BE IN THE DEMISED PREMISES. COORDINATE THE FINAL CONNECTION OF ALL UTILITIES (INCLUDING CHILLED AIR) WITH THE LANDLORD'S FIELD REPRESENTATIVE. 4. T.G.C. SHALL MAINTAIN ALL LANDLORD RETURN AIR OPENINGS (WITH FIRE DAMPERS IF REQUIRED) IN DEMISING WALLS TO ENSURE OPERATION OF LANDLORD CENTRAL VAV SYSTEM. VERIFY WITH HARRY PRAHL PRIOR TO BID. MECHANICAL GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, LAWS, ACTS AND ALL AUTHORITIES HAVING JURISDICTION, AND LANDLORD'S CRITERIA. 2. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLI- CABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY; AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRO- DUCT APPLICATION AND INSTALLATION. 3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, DOCUMENTS AND SERVICES RELATED TO INSTALLATION OF THE WORK. 4. PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT ALL EXISTING CONDITIONS TO INSURE THAT THE WORK REPRESENTED ON THE DRAWINGS AND IN THESE SPECIFICATIONS CAN BE INSTALLED AS INDICATED. 5. DUCTWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH ASHRAE AND LATEST SMACNA STANDARDS. PROVIDE TURNING VANES IN ALL ELBOWS; AND MANUAL VOLUME DAMPERS IN ALL BRANCHES, SPLIT - PER DAMPERS, AIR EQUALIZERS, EXTRACTORS, AND SIMILAR DEVICES WHEREVER NECESSARY TO PROPERLY BALANCE THE SYSTEM AND PRODUCE A QUIET AND DRAFTLESS OPERATION. 6. EXPOSED DUCTWORK SHALL BE STANDARD SPIRAL ROUND GALVANIZED SHEET METAL DUCTWORK. 24 GAUGE UP TO 36 "0, 22 GAUGE -36" TO 50 ". FIRST 15 FT. OF DUCT FROM EQUIPMENT SHALL BE LINED 1" HEAVY DENSITY ACOUSTICAL INSULATION. 7. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX "M -KE" WITH ONE INCH EXTER- NAL INSULATION FINISHED WITH A VAPOR BARRIER, U.L. AND 90A LISTED, SHALL BE EQUIPPED WITH DAMPER- EXTRACTOR AT THE SHEETMETAL DUCT AND CIRCULAR COLLAR AT THE DIFFUSER, MECHANICALLY SECURED. 8. FLEXIBLE DUCTWORK SHALL NOT EXCEED 4 FEET IN LENGTH; BENDS SHALL NOT RESTRICT THE INSIDE CROSS -- SECTIONAL AREA OF THE DUCT; AND CONNECTION SHALL BE MADE AS DIRECT AS POSSIBLE TO THE MAIN SUPPLY. 9. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION AND SERVICE OF EQUIPMENT. 10. PROVIDE A READY -TO -USE SYSTEM WITH ALL WORK GUARANTEED IN WRI- THING AGAINST DEFECTIVE WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM TURN OVER TO OWNER. 11. CONDENSATE DRAINS: TYPE "M" HARD DRAWN COPPER FOR LINES 1" AND SMALLER, "DWV" HARD DRAWN COPPER FOR 1-1/4" AND LARGER, CONFORMING TO ASTM B88 -72. WROUGHT COPPER FITTINGS, DRAINAGE TYPE FOR LINES 1 -1/4" AND LARGER. SOLDER WITH 50/50 SOLDER. 12. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 GALVANIZED SHEET METAL WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5' -0" DUCTWORK MATERIALS SHALL BE PER INTERNATIONAL MECHANICAL CODE, 2003. 13. PROVIDE AS PART OF THE MECHANICAL CONTRACT SERVICES OF AN INDEPENDENT AIR /WATER BALANCING CONTRACTOR CERTIFIED BY THE ASSOCIATED AIR BALANCE COUNCIL. SUBMIT 3 COPIES OF THE BALANCE REPORT TO ARCHITECT /OWNER. 14. PROVIDE DUCT SMOKE DETECTORS IN SA DUCTS, TO OVER RIDE UNIT AND PROVIDE SHUTDOWN WHEN UPON DETECTION OF SMOKE_ HVAC NOTES 1. ALL WORK TO BE AS PER THE L.L. SPECS, ALL LOCAL CODES, RULES AND REGULATIONS. ALL WORK TO BE AS PER ASHRAE AND SMACNA GUIDELINES. 2. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE. ALL DUCTS TO BE SHEET METAL DUCTS AS PER ASHRAE AND SMACNA GUIDELINES. 3. PROVIDE NECESSARY TURNING VANES, SPLITTER DAMPERS, VOLUME EXTRACTORS AND OTHER FEATURES NEEDED FOR A SMOOTH AND CONTROLLED FLOW OF AIR. 4. LOCATIONS SHOWN OF HVAC EQUIPMENT AND DUCTS ARE SCHEMATIC ONLY. VERIFY STRUCTURAL DETAILS AND OTHER DETAILS THAT WILL AFFECT ROUTING AND PLACEMENT OF THESE COMPONENTS. IF MORE SUPPORTS ARE NEEDED FOR HVAC EQUIPMENT, COORDINATE WITH THE ARCHITECT. 5. PROVIDE PROPER DUCT TRANSITIONS FOR ACTUAL HVAC UNITS INSTALLED. ROOF PENETRATIONS, IF ANY, TO BE MADE AS PER L.L. SPECS. VERIFY DETAILS WITH L.L.. 6. PROVIDE AND INSTALL THERMOSTATS AT LOCATIONS AS DIRECTED BY THE ARCHITECT. 7. COORDINATE ACTUAL LOCATIONS OF DIFFUSERS, REGISTERS AND GRILLES WITH CEILING DETAILS AND OTHER FEATURES SUCH AS LIGHTING FIXTURES ETC. THAT MAY AFFECT PLACEMENT OF THE HVAC SYSTEM COMPONENTS. 8. GENERAL CONTRACTOR SHALL SUPPLY ALL EQUIPMENT CONTROLS AND WIRING. COORDINATE WITH MALL REPRESENTATIVE FOR INTERLOCKING WITH MALL CONTROL SYSTEM (AS REQUIRED). DUCTWORK SYMBOLS COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. as 2 co co 4° � r W u 1-J • z rcz `i= ..0 aIX r_ tn 4 DATE October 15th, 200"1 SHEET: a PROJECT No.: 0 HOT -01-024 tfl rn cu tri ea m 0 ce d. v u1 � Ln - 0 00 0 c O U N � E Q m 0 0 0 m t z T co LI to i O a¢ a C fa a ta ,7 -C E O H O 13 of 17 FIXTURE SPECIFICATIONS FIXTURE CONNECTIONS FIXTURE UNITS MARK DESCRIPTION MANUFACTURER AND MODEL NUMBER FITTING ACCESSORIES/ REMARKS COLD WATER HOT WATER WASTE VENT QUANTITY OF FIXTURES WATER F.U. WASTE F.U. EACH TOTAL EACH TOTAL HWC HANDICAPPED WATER CLOSET "KOHLER" HIGH LINE LITE PRESSURE CLEAN #K -3493 FLUSH TANK 1.4 GPF VITREOUS CHINA, 17.25" HIGH ELONGATED BOWL, PROVIDE SOLID PLASTIC SEAT WITH OPEN FRONT AND COVER 1/2" - 4" 2" 1 2.0 2.0 6 6 LAV LAVATORY WALL HUNG 0.5 GPM FLOW "AMERICAN STANDARD" #0355.012 LUCERN "RELIANT" #2385.063 SINGLE LEVER FAUCET PROVIDE WITH "TRUEBRO" HANDI LAV - GUARD #102 P- TRAP AND WATER LINES INSULATION PER HANDICAP. REQMTS. AERATOR, CAST GRID STRAINER, 1-1/4" O.D. TAILPIECE, CHROME FINISH 1/2" 1/2" 2" 1-1/2" 1 0.5 0.5 1 1 FD FLOOR DRAIN "J.R. SMITH" #2005 -A - _ ROUND TOP W/ TRAP PRIMER CONNECTION FLOOR DRAIN (F.D.) 2 1 -1/2" 1 - - 3 3 IWH ELECTRIC WATER HEATER "EeMAX" #SP2412 2400 W HEATING ELEMENT 23 GPH CO 80 °F RISE SEE ELECTRICAL DRAWINGS FOR VOLTAGE /PHASE 1/2" 1/2" - - 1 - - POINT OF CONNECTION ' EDF ELECTRIC DRINKING FOUNTAIN "OASIS" #PF8AM (SINGLE LEVEL) - FRONT PUSH PAD ACTIVATION 1 -YEAR WARRANTY 1 /2" _ 2" 1 -1 /2" 1 0.25 0.25 1 ' 1 NOTE: 1. PLUMBING CONTRACTOR SHALL VERIFY QUANTITY OF PLUMBING FIXTURES REQUIRED FROM THE PLUMBING PLANS. 2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING FIXTURES SHOWN ON THE PLUMBING PLANS WHETHER LISTED OR UNLISTED ON THE FIXTURE SCHEDULE. TOTALS 5 14 PLUMBING GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, LAWS, ACTS AND ALL AUTHORITIES HAVING JURISDICTION. 2. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL LANDLORD'S REQUIREMENTS; APPLICABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY; AND THE MANUFACTURER'S STRICTIST RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION. 3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, DOCUMENTS AND SERVICES RELATED TO INSTALLATION OF THE WORK. 4. PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT ALL EXISTING CONDITIONS TO INSURE THAT THE WORK REPRESENTED ON THE DRAWINGS AND IN THESE SPECIFICATIONS CAN BE INSTALLED AS INDICATED. 5. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES AND PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION AND SERVICE OF EQUIPMENT. 6. SOIL AND VENT PIPE SHALL BE CAST IRON NO -HUB PIPE. 7. COPPER PIPE SHALL BE USED FOR ALL WATER PIPING EXCEPT SERVICE FROM METER TO BUILDING. TYPE "L" HARD DRAWN COPPER SHALL BE USED FOR PIPE NOT SET UNDER CONCRETE. TYPE "K: SOFT COPPER SHALL BE USED FOR PIPING UNDER CONCRETE. FITTINGS SHALL BE WROUGHT COPPER THROUGHOUT. 8. INSULATE HOT & COLD WATER LINES WITH 1/2" THICK "ARMAFLEX" INSULATION. 9. SLOPE ALL SEWER LINES AT 1/4" PER FOOT, UNLESS OTHERWISE NOTED. PLUMBING SYMBOL LIST SYMBOL DESCRIPTION SYMBOL DESCRIPTION SOIL WASTE LINE (W) < SHUT OFF VALVE (GATE) — - - - VENT LINE (V) — 1---- --- 1 — CHECK VALVE • COLD WATER (C.W.) — 11 I-- UNION • • HOT WATER (H.W.) — 1V1 — LUBRICATED PLUG VALVE — — — • - • - HOT WATER RETURN HOSE BIBB (H.B.) 1 GAS LINE -- BRANCH RISE OFF MAIN — G — TEMPERED WATER 0 S.C.O. SURFACE CLEANOUT TW DRAIN LINE 0 F.C.Q. FLOOR CLEANOUT RECEIVf=n D BUILDING SEWER — 1>e<— GLOBE VALVE CITY OF TUKWIEA -- f--I 0 FLOOR DRAIN (F.D.) BALL VALVE UkC 1 S 2007 — I i-- Al FLOOR SINK (F.S.) - R.D.L, ROOF DRAIN LEADER PERMITCEN�-ER Q ROOF DRAIN (R.D.) - O.D.L. OVERFLOW DRAIN LEADER OVER FLOW DRAIN — CD CONDENSATE DRAIN LINE —I WCO WALL CLEANOUT — ICW — INDUSTRIAL COLD WATER POINT OF CONNECTION LAVATO PROVIDE BALL VALVE. UNION WATER ME 3/8" HOT WATER T FAUCET AS SHOWN ON PLAN INSTANTANEOUS TYPE WATER HEATER MOUNTED ON WALL BELOW LAVATORY PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS NOTE: HOT WATER HEATER AND ALL EXPOSED HOT WATER PIPES ABOVE FLOOR TO BE NODDED (INSULATED AS REQUIRED BY STATE & LOCAL CODES). WATER HEATER DETAIL 4 4 Q d a4 6 ' ° Q• HOT AND COLD WATER SCHEMATIC LAV TO TRAP PRIMER CONNECTION AT FD MAY EXTEND AS A WASTE OR VENT CHROME WALLCOVER & SCREW. WALL PLUGGED TEE W /CLEANOUT FLOOR L I N E 1/8" C.I.BEND INSTANTANEOUS WATER HEATER 1 -1/2" VENT UP IN WALL 3/8" COLD WATER TO FAUCET AS SHOWN ON PLANS 1/2" COLD WATER IN WALL SHUTOFF VALVE 2" SANITARY WASTE • BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. WALL CLEANOUT DETAIL FLOOR N.T.S. N.T.S. PROVIDE INDIVIDUAL SHUT OFF VALVE AT FIXTURES AS REQUIRED. PROVIDE 12" CHAMBER (TYP) 3/8" SUPPLY WITH STOP (TYP) NTS EXTEND 3" VENT TO LANDLORD COMMON EXHAUST DUCT STUBS, VERIFY EXACT LOCATION IN FIELD. EXTEND 4" S5 TO EXISTING SYSTEM, VERIFY EXACT LOCATION, FLOW AND DEPTH. LANDLORD NOTES 3" FD W /TRAP PRIMER TENANT SHALL PROVIDE AND INSTALL A REDUCED PRESSURE BACK FLOW PREVEN TER ON THEIR WATER SERVICE WITHIN THEIR SPACE PRIOR TO MAKING ANY OTHER CONNECTIONS TO THE WATER SERVICE PIPING. WASTE AND VENT SCHEMATIC ■ NOTE: PRIOR TO CONSTRUCTION/ BID THE CONTRACTOR SHALL VISIT THIS SITE AND FIELD VERIFY THE EXISTING LOCATIONS AND SIZES OF PLUMBING LINES AND FLOW DIRECTION. THE CONTRACTOR SHALL FIELD VERIFY ANY/ CONDITIONS WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON THESE PLANS. NOTIFY ARCHITECT. ∎ 1El't a A . PLUMBING FIXTURE SCHEDULE NTS EXTEND 4" SS TO EXISTING SYSTEM, VERIFY EXACT LOCATION, FLOW AND DEPTH. TO I LET ROOM 1 106 PLUMBING FLOOR PLAN NTS NOTE: ONLY THOSE SYMBOLS SHOWN ON THE DRAWING APPLY COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. 76 17) N �+ roe w a) 4.J � +� • s > 0 +- m al W Z -C CD § > 1411 tnatC1 M .1412 SCALE: 0 la W Z } ( .4 x er Z Z O' c . L d N 2 a wo�n W 5H = a w >F .Z 00.g a DRAWN BY: PROJECT No.: ms c 0 0 ce 1/4 " =1' -0" DPE W H 0 Z y� Z W g aci a 0 z z < Ei � 2 7 4 a W Ci DATE: October 15th, 20D7 SHEET: �1 cn 0 a, 0 u as as g g P1 0 0 co o 01 u 0-1 V 0 oo 47 t-- HOT -07 -024 14 off 11