Loading...
HomeMy WebLinkAboutPermit PG07-290 - WESTFIELD SOUTHCENTER MALL - BORDERS BOOKSBORDERS BOOKS 2437 SOUTHCENTER MALL PGO7-290 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Citiof Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2437 SOUTHCENTER MALL TUKW BORDERS BOOKS 2437 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: MICHAEL A CHIODINI Address: 1401 S BRENTWOOD BL , ST LOUIS MO Contractor: Name: BIENER PLUMBING Address: 4033 UNION AVE , TACOMA WA Contractor License No: BIENEP* 190BP Value of Plumbing /Gas Piping: $210,000.00 Fees Collected: $561.00 plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC-10 /06 PLUMBING /GAS PIPING PERMIT DESCRIPTION OF WORK: PLUMBING AND GAS PIPING FOR NEW TI, INCLUDING BACKFLOW PREVENTER FOR CARBONATOR EQUIPMENT AND PRESSURE VACUUM BREAKERS. Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing (cont.) O Building sewer and each trailer park sewer 1 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 2 O Industrial waste treatment interceptor, including 1 its trap and vent, except for kitchen type 2 grease interceptors 0 O Repair or alteration of water piping and/or water 4 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 4 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 4 Medical gas piping (6 +) inlets /outlets 0 4 Gas Piping 1 Gas piping outlets (0 -5) 4 5 Gas piping outlets (6 +) 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 314 725 -5588 Phone: 206 - 531 -9261 Expiration Date: 09/06/2009 PG07 -290 03/03/2008 08/30/2008 PG07 -290 Printed: 03 -03 -2008 Permit Center Authorized Signature: Signature: Print Name: doc: UPC-10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO7 -290 Issue Date: 03/03/2008 Permit Expires On: 08/30/2008 Date: I -' I hereby certify that I have read and •x• ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • , whether specified herein or not. The granting of this pe • does not • resume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th • erf - c of 1 r . I am authorized to sign and obtain this plumbing /gas piping permit. Date: _ J This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -290 Printed: 03 -03 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: BORDERS BOOKS 1: ** *PLUMBING AND GAS PIPING * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2437 SOUTHCENTER MALL TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG07 -290 ISSUED 10/31/2007 03/03/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 14: The applicant must notify the City Utility Inspector at (206)433 -0179 upon commencement and completion of bacldiow installation work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. 15: BACKFLOW devices and vacuum breakers shall be WA State Department of Health approved devices. doc: Cond -10/06 PG07 -290 Printed: 03 -03 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: I; / doc: Cond -10/06 PG07 -290 Date: 5 —3 r v ordinances governing or local laws regulating Printed: 03 -03 -2008 Tenant Name: Property Owners Name: Name: Company Name: C Mailing Address: Company Name: 2. 5 6/0W/A /b) Mailing.± Address:1S 7,060 � �f 5 fi /// Contact Person: P4!/ E -Mail Address: slew' CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwiv.ci.nik-Ivilawa.us Q• Ap lic..ions Form;- ipcl'c:ninn. tIn Line ? -2 - Pemtn 4pp licannn.dm- Rr. lied: 9 -200e oit Project No. Building Permit No Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No 1 15 • (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION N b 1 11 0�W t t y t �o A ssessor's Tax No.: ±4 a5 � y Site Address: ��x�� " — '-/� ��^�^"`� � Suite Number: Floor: Ff� Mailing Address: 1�6 D/ / //.41 ,a4). ''tJ�-11 bbl n Address: `'!<.J 1 S• V Contact Person: E -Mail Address: Contractor Registration Number: A' IoDJWJ ' E -Mail Address: r ►l y� - ll ei •l w .. u1 1 New Tenant: Yes ❑..No ,d 1o5. 4.fd�s City 9a s. State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued �Y D , ay Telephone: Maili g �( �/�/� J m0 E -Mail Address: alIOPI•V h �/ LODI •L(/' \ City Fax Number: 3114_ "" S tntc — � 1 Zip �1( GENERAL. CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) — - 1 1 — Company Name. Mailing Address: City Day Telephone: Fax Number: Expiration Date: State 5 eI Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record AA AI_ .1 3 4 Contact Person: l , .t■ tl. A. . o 10D t City State e� Zip g 1 Day Telephone:: -125- 9 5586 Fax Number: 314- 1S - -1U ENGLNEER OF RECORD - All plans must be wet stamped by Engineer of Record d JW; «;: � St ate J !p Day Telephone: Igo- 87 / /� Fax Number: Pate 1 of 6 BUILDING PERMIT INFORi ION - 206 - 431 -3670 Valuation of Project (contractor's bid price): S 1 MIU)O Existing Building Valuatioon: $ Scope of Work (please provide detailed information): 1/ti7 l(7L f7all letz, �h 4 vg io/ A swat S " Floor 2 Floor ~' 3' Floor ' Floors ru '13asemen ?1,. Accesso -Structure* ry • Attached Garage .Detached Garage = ; Attached Carport r Detached Carpo Yi. Covered Deck • Uncovered; Deck: Provide All Building Areas in Square Footage Below Interior Remodel Addition to Existing Structure 0..og Type of Construction per IBC Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of t foundation of all structures, plus any decks over 13 ches and overhangs greater than (3 inches) *For an Accessory dwelling, provide t following: Lot Area (sq ft): , Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation at shows that the principal owner lives in one of the dwellings as his . her primary residence. Number of Parking Stalls Pro ' ded: Standard: Compact: Handicap: Will there be a change in u '? ❑ Yes ❑ No If "yes ", explain: Will there be new rac torage? ❑ Yes . No If yes, a separate permit and plan submittal w be required. FIRE PROTECTI . ` /HAZARDOUS MATERIALS: Spri iaers X Automatic Fire Alarm ❑ None ❑ Other (s•ecity) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ es No 1f - f-es', attach list of materials and storage locations on a separate 8-1/2 x 11" paper including quantities crnd ;t. C. rial Scrfen Data Sheets. SEPTIC SYSTEM ❑.......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: Apnlicarinns Forms- Applieuinns 1)n Line :;.2011,1. Pemrir - tpplicarinn.doc Rcviscd: 9.1004 Sh Page 2 of h Fixture Type: ' Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath,'shower O Drinking fountain or water cooler (per head) x Wash fountain 0 Gas piping outlets /�y� 1{d0E' Bidet O Food -waste grinder, commercial O Receptor indirect waste E Clothes washer. domestic () Floor drain Sinks Dental unit. cuspidor () Shower, single head trap Urinals Dishwasher, domestic, with independent drain ' Lavatory 4 Water Closet Building sewer or trailer park sewer water system — per drain (inside building) /� V Water heater and/or vent �j• Additional medical gas inlets/outlets — six or more Industrial waste pretreattnent interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment O Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets'outlets for specific gas O PLUMBING AND GAS PIPING PERMIT INFORMATION - 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION c Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): S 02400 Valuation of Gas Piping work (contractor's bid price): $ 101 MO f Work (ple e provide detailed information): f ' f � K/ 1iWJ Scope o I -s t c � k QrApplicani i. F.nn.._ApphcaIn.n% On L :nc i.'lh,n . Purina ' Appii.:ainn.d::c R:•. ik.f: 4 -:(aln bh Building Use (per Intl Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Patti: 5of6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI \G OWNER .aUTH�D AGENT: Print Name: oavile A. C /EVA// Mailing Address: / G 9 147 Signature: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Date Application Accepted: jolvA 1/0- 0. Applic:uion.,, Fume- A.,piications ■)n Line 3 -21uth - Pcmm App1icaoon. dcc Rc-.iscd: 9 -_606 bh Date Application Expires: Date: eM7 Day Telephone: 3!I 7z5-6503 5flaiS 634. City State Zip ccipt Staff Initials: Pa_e6iof6 Parcel No.: Address: Suite No: Applicant: Receipt No.: R08 -01668 Initials: WER User ID: 1655 Payee: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us 6364200010 2437 SOUTHCENTER MALL TUKW BORDERS BOOKS BIENER PLUMBING TRANSACTION LIST: Type Method Descriptio Payment Check 19286 ACCOUNT ITEM LIST: Description Account Code PLUMBING - NONRES 000/322.100 RECEIPT Amount 58.00 Current Pmts 58.00 Total: $58.00 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 558.00 Payment Date: 05/15/2008 02:07 PM Balance: $0.00 2496 05/16 9710 TOTAL PG07 -290 ISSUED 10/31/2007 03/03/2008 58.00 doc: Receipt -06 Printed: 05-15 -2008 RECEIPT NO: R07 -02378 Initials: JEM User ID: 1165 Payee: WESTFIELD SET ID: S000000882 SET TRANSACTIONS: Set Member Amount D07 -407 EL07 -635 M07 -232 PG07 -290 TOTAL: TRANSACTION LIST: Type Method Payment ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.d.tukwila.wa.us 11,476.92 4,127.50 1,896.75 561.00 18,062.17 BUILDING - NONRES ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE Description Check 06008923 SET RECEIPT TOTAL: Payment Date: 10/31/2007 Total Payment: 18,062.17 SET NAME: Tmp set/Initialized Activities Amount 18,062.17 18,062.17 Account Code Current Pmts 000/322.100 6,952.98 000.322.101.00.0 3,302.00 000.345.832.00.0 825.50 000/322.100 88.00 000/322.100 1,523.40 000/345.830 4,996.79 000/322.100 369.00 000/386.904 4.50 TOTAL: 18,062.17 Project: 4. or e Type of Inspection: F� Address: g t / , 7 /, „ / f // Date Called: Special Instructions: Date Wanted: 7//64 a.m. p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING-DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 P6d 7-aVI PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1)Z ' $58. f INSPECTION FEE REQUIRED. Prior to inspection. fee must be paid - 6300,Sobthcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Proj�,t: ` 1� P,��� Type of Ins�eC,tion: 1-- I cV14 1 Arts; . hi j Date Called: Special Instructions: Date Wanted: � mm �_ � "�_ p.m. Requester: Phone _ - - � 6 �. 5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: C 'Inspector: 'Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: ryl. F..". jt, r,,, ii 04-+ 1 2 1 1,. ,, L...lr ti.:4 f ,,.,," / Ad . res i s: 37 ( 1 6r-- 4 - rt, ...- C> ,'1-. psi Iy C,ot, c.,,,„rd " ' .4.4 41-C r 4: K,,,ey 69 on o /710 Special Instructions: iC To 51 i kFF Co k si (nJ Ci:t.)\ -00 a.m• Requester: Phone N 2 5 PrOje.26 a �, icA d , 1 i 1 , 0 0 � 7 Type of Ins ection: -FI N A ( A I t.tiW( 1/1 Ad . res i s: 37 ( 1 Date Called: Special Instructions: Date Wanted: - 7 -/( -00 a.m• Requester: Phone N 2 5 o ( ,-- � ' 5 Z� INSPECTION NO. (Inspector: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approvedper applicable codes. Corrections required prior to approval. Date: P66 El $60.di7 FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Type of Inspection: F /,v / 5 ^ /Ill 7r'.^, aL+ Address: 29,37 »// r,,, fry S r mss( 11,/ 5. Alee4wrF,e4f , ins G , <</ g4-ek- PIS,_ r °, «. s Calk T0,•4 r. rb.., Requester: N't f 11 ?! 4.11.- i n urH, ), t 6.,d 41 5,'.45 Project: YID cdeys)goo e 5 Type of Inspection: F /,v / Address: 29,37 »// Date Called: Special Instructions: Date Wanted: — /2 - 0 p.m Requester: Phone No: ti P6 72Q ( j INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 LJ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit El Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: ProjG_ Type of P Wit) = C {(_ - 14 7 Ad,clres 3 Date Called: Special Instructions: Date Wanted: D m, Requester: Phone No _, g - 2- 2 2 4q 7 / 0 6°7 z� CI INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 3 INSPECTION RECORD Retain a copy with permit M Approved per applicable codes. El Corrections required prior to approval. COMMENTS: l (f 01447 till P4.r f, f #., ( -p, (Inspector: I Date: -44-0 I/ ID $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: !Date: Project: Project: Typ % ) /4 ,t,, ; j spection: 64W11) Date Called: Address: a. I /3 7 4 // Special Instructions: Date Wanted: / c — 5' I (o -6rre Vim^ p. Requester: Phone No: c253 2ZZ -5' 7/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 X07 -.5'2 PERMIT NO. (206)431 -3670 LJ Approved per applicable codes. Corrections required prior to approval. COMMENTS: !fin 06- -eitcyf Inspector: 0 $58.OtfREINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Date: Project, 1 .0 1r 1E5 (c5 Type,of Inspection: z ON ri k - 1 i\-) Piu ro f ) Address: :2 t-13 - 7 Sent, toft.gev Date Called: _:'• iln 14- 11 Special Instructions: Date Wanted: LI 2 3 --- sc? a. m. Requester: Phone No: 5 322 . --- 7 1 INSPECTION NO. CITY OF TUKWILA DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 El Approved per applicable codes. COMMENTS: 1:1 ec 8 I Rece t No.: INSPECTION RECORD Retain a copy with permit a Kick T- C bt&A/ Reht5h-,\)-4pix ".< -p war? u-) 44e [2-em A /1 IT 0 REINSPE ION F E REQUIRED. at 6300 Southcenter Blvd.. Suite 1 Date rior to inspection, fee must be . Call the schedule reinspection. 'Date: P6o7-25 0 PERMIT NO. EI Corrections required prior to approval. Job Name Job Location Engineer Approval Watts No SD -3 Backflow Preventer for Carbonated Beverage Machines Sizes: 1 /a ", 3 4" (8,10mm) Series SD3 is a dual check with atmospheric port designed for the protection of the water supply from carbon dioxide gas and carbonated water. These substances can flow from post -mix beverage systems and are very acidic. If the acidic water comes in contact with copper tubing or copper pipe, it win cause the leaching of copper salts into the water supply. The dissolved copper if ingested can cause nausea, abdominal pain, and in some cases vomiting. The SD3 prevents the reverse flow of potentially contaminated water into the potable water supply due to back pressure backflow and is used for continuous or intermittent pressure conditions. The SD3 atmospheric vent provides a visual indication of failure in the event that the downstream check fats and system backpressure exceeds the supply pressure The Watts SD3 is recommended for use on Post -Mix Carbonated Beverage Equipment and dispensing equipment for tea and coffee. Features • Certified to ANSI/NSF Standard 18, Manual Food and Beverage Dispensing Equipment • ASSE 1022 Approved Dual Check with Atmospheric Vent • 316 stainless steel body for corrosion resistance • M rubber compounds comply with FDA food additive regulations • Streamlined body design minimizes pressure Toss and cavitation • A wide variety of custom end connections are available • Endurance tested for more than 500,000 pumping cycle •Atmospheric port provides visual indlca second check • Wye pattern strainer model for water Contractor Represe s e f , FILE COPY ES-SD3 on Health'' :Hazard Appl�cafons APProval K ermit No. Contractor's P.O. o. L ' !: c `c'2i i3 £UDJeCt i 0 errom and e T' f'nrre t ... _ . Available Models W (8rnm) SD3 -MN: Male NPT W (10mm) SD3 -MN: Male NPT '4 (8mm) S03 -FN: Female NFT W (10mm) SD3 -FN: Female NPT W (8mm) SD3 -MF: SAE Male Flare 34' (10mm) S03 -MF: SAE Male Flare /' (10mm) SD3- MF -LS: SAE Male Flare, less strainer Note: The above connections are available as outlet connections only. Strainer inlet connection is always Female NPT. Specifications Back low preventer body and adapters are of 316 stainless steel construction and all rubber components comply with FDA food additive regulations. Aft materials in contact with the potable water are in compliance with the requirements of the Safe Drinking Water Act, Public Law 93 -523, National Interim Primary Drinking Water Regulations. Strainer manufactured from IVSE4pproved acetal plastic. RECEIVED CITY OF TUKWILA JAN 282C'3 PERMIT CENTER �A p 1r i maiwREGULATOR City ` ir Watts product specifications in U.S. customary units nc are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design construction, specifications, or materials with- out prior notice andwithout incurring any obligation to make such changes and modfications on Watts products previously or subsequently sold. CORRECTION ?RA. V%O LTR# Z L Standards ASSE 1022 Installation: The valve can be installed horizontally or vertically (flow up or flow down). The valve should be trhstalled so that the strainer and the valve are accessible for service and main- tenance. In the event the second check valve becomes fouled, the vent port opens to atmosphere and water and CO2 Gas Is discharged. Connect a vent discharge line to the vent outlet of the SD3 and vent to a safe place of disposal wtlh adequate ven- tilation in order to prevent personal injury ry or damage. The valve should be installed such that water discharge from the vent will not cause damage to the surrounding equipment or properly. important The device should not be Installed inside a wall or in a concealed location. Copper tubing shall not be used on the downstream side of the bacldlow prevents Dimensions (approx.) 74 : SIZEIDIri„ PART#ASSEbi81a'> ?DADEA - 61 mm W 8 W 10 c h 7 11/2 1 7,t 74 mm 4 48 4' e in mm 11'hs 43 111Ra 43 11 43 11'/4 •a/9' 10 SD3- GF-LS 0061671 For use on pos pumping installations only. Capacity tr, 0r a at7 30 in 1s 136 23 g+e 103 Is p 60 10 sr s 0 0 0 0 ES -SD3 0212 21 '/4 (8mm) SD-3 .66 1 21 3A 4.t Row 12 4 114 2sA 67 u 61 A LEADER U rpm 51 'pi Pressure/Temperature Max. Pressure:150psi (10 bar) Max. Temperature: 130 °F (54°C) Typical Installations Wate Supply Installations Valve SD3 Backtlow Preventer Post Pumpirng installations Valve Strainer r Water Supply Water Supply ta, cal 207 30 172 25 mt 139 20 all 103 12 69 169 10 d 31 3 00 0 0 Plastic Pipe Strainer Vent Discharge Une Filter Vent Discharge Line Carbonator HA and CO2 CO2gas in vented area 1 97 11/2 ',Vs ?7 .23 as W (10mm) SD-3 28 2.3 Flaw 48 /M VALVE mem/ oat - ..,., A . REGULATOR — 51.... 1574 Yralts I stusl ..ea. OIC. Water Products Dtvlston • Safety & Control Valves USA: 815 Chestnut Si, No. Andover, MA 01845 -6098; wwwwattsreg.can Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; ww,vwattscda.com O Watts Regulator Co., 1998 SD3 MF-LS Backflow Preventer Beverage spenser Carbonated Beverage Dispenser 11 43 11'Ae 43 2.4 11 Printed in U.S.A. r Health Hazard and Continuous Pressure Applications Job Name Job Location Engineer Approval Series 008PCQT Health Hazard, Anti- Siphon, Spill- Resistant Backflow Preventer Sizes: %`, h ", 3 /a` and 1" (10, 15, 20, 25mm) Series 008PCQT is designed for indoor point -of -use applica- tions to prevent backsiphonage of contaminated water back into the potable water supply. Separation of the water supply from the air Inlet Is accomplished by means of a diaphragm seal. This feature protects against any spillage during start-up or operation. Features • Standardly supplied with Internal polymer coating • Standardly supplied with Tee handles • Available less Tee handle with stem wrench fiats. For use where space is limited • Available in left- handed or right- handed outlet • Patented design • Spill- resistant design for indoor use • Affordable design • Modular cartridge for ease of service • Vent uses an O-ring for reliable operation • Bronze body for durability • Compact space saving design • Satin chrome finish available • Available with strainer Installation The 006PCQT is designed to be installed at the point of use. When factory installed decWmachine mounted on machines or equipment, the critical level of the OO8PCQT shall be not less than 1 • (25mm) above the flood rim. If field applied for general plumbing applications, the critical level of the OO8PCOT shall be a minimum of 6' (150mm) above the flood rim. Specifications A spill-resistant vacuum breaker (SVB) shall be installed, in accordance with the manufacturer's instructions, as noted on the plans. The valve shall consist of a one -piece modular check and float assembly made of engineered thermoplastic and housed in a bronze body. Springs shall be stainless steel. The valve shall be constructed with a mokded diaphragm sepa- rating the air inlet from the potable water supply to prevent spillage. The valve shall be a Watts Regulator Company Series OO8PCQT. Contractor Approval Contractor's P.O. No Representative ES-0O8PCOT 0o8P0Q1:-L (Left Handed MINN • r �° 111. s1 , Y1; ilk alp sEeps O OOePCQT (Right Handed) INWATTS® Watts product specifications in U.S. customary units and metric are approximate and areovided for reference only. For precise measurements, please contact • notice and without Inouring any obligatio reserves make changes and oddificatons on 9 Wa is products construction, slyy o s sold. ` 5125 1010 - - - 200 3 BU3E3SI05 . 79 3.4 1.54 '4 WEIWR - %,' h MIS in 8 mm D 91 mm It E mm ®o. by 34 10 5'h 114 140 3441 0 5 10 15 20 ?5 30 0 19 3e 57 78 55 114 ` 5125 1010 - - - 200 3 BU3E3SI05 . 79 3.4 1.54 '4 WEIWR - %,' h MIS in 8 mm D 91 mm It E mm ®o. by 34 10 5'h 114 140 3441 100 3'% 114is 79 1.6 .73 ' 15 534 3.45 146 414e 106 3% 86 1.7 .77 44 20 II 0 19 5 10 13 31 33 57 7e 25 05 30 2) 40 45 50 114 133 152 171 190 ` 5125 1010 - - - 200 3 BU3E3SI05 . 79 3.4 1.54 '4 WEIWR - %,' h MIS in 8 mm D 91 mm It E mm ®o. by 34 10 5'h 114 140 3441 100 3'% 114is 79 1.6 .73 ' 15 534 3.45 146 414e 106 3% 86 1.7 .77 44 20 7 178 4% 117 41/2 114 3.8 1.72 1 25 7'k 191 5'4 130 4 124 4.8 2.18 36 10 7% 200 3 100 3'% 79 3.4 1.54 '4 15 8'% 216 434e 106 3 86 3.5 1.59 3 /4 20 10' 260 454 117 4'h 114 5.6 2.54 1 25 114is 284 554 130 4 124 7.6 3.45 Materials Springs: Bonnet: Vent Disc: Disc Holder Check Disc: Body: Pressure - Temperature Temperature Range: 33 °F -180°F (0.5°C - 83°C) Maximum Working Pressure 150psi (10.3 bar) End Connections Female NPT - Ball Valve shutoffs icy As corrlplled from documented Foundation for Crass - Connection Control and Hydraulic Research at the University of Southern CalfomIa lab tests. *Typical malarrlum system lbw rate (7.5 feet/sec.) 5w p 55 10 5:5 5 41 9 22 4 14 2 O 0 0 O 11 psi in is 13 12 193 15 ss AP u 5 2a 4 14 2 O 0 03 19 >s O 2 O 15 7.0 ROW Stainless steel PPO EPDM PPO Silicone rubber Bronze 15 5.7 2 79 3 4 11.4 112 Dimensions — Weights - 29 ..I Me (10nrrn) 23 95 114 RDW 169 (r5mm) 5 19 73 23 3 %WATTS® 6aoktlow Prevention Products ES- 008PCOT 0642 e 33 173 4 43 152 17.1 7 27 9 30 008PCOT S 9 34 5 u 19 21 p+ ffi419 Standards Meets requirements of IAPMO. Approvals G 1056 864.1.2 Listed by IAPMO, Approved by the Foundation for Cross - Connection Control & Hydraubc Research at USC. AP 3P AMER 1111:11110 i ramirCriorr,! i Trd 121 , 5 anmlr i 1.1 - 9ta pd ® 10 55 41 Za 4 14 2 O 0 Its psi 5910 55 9 n 25 4 14 2 O 0 s>sd, Haut RDW Z3 9g4 MU A strainer is recommended b L hslated afield of the baddlow prevader ks ravel Die foam of the check assembly w31 resulting 591laye from the VOW damp repessnitalfoa Do notiatall h concealed locators or areas where water Iralage due l3 normal wear of the Menial parts cm cause damage. 008PCOT 344' (2Cnim) • 7.5 23 1'( Typical Installation rva 94a Rau ISO DMI USA: 815 Chestnut St., No. Andover. MA 01845-6098; www.watts.com Canada: 5435 North Service Rd, Bufngten, ONT. L7L 5H7; wwa.waitscanazb.ca ® Watts Regulator Company, 2006 January 17, 2008 Michael Chiodini 1401 S Brentwood Bl St Louis MO 63144 Dear Mr. Chiodini, S cerely, Brenda Holt Permit Coordinator encl 46A- xc: File No. PG07 -290 RE: CORRECTION LETTER #2 Plumbing /Gas Piping Application Number PG07 -290 Borders Books — 2437 Southcenter Mall City of Tukwila, Jim Haggerton, Mayor Department of Community Development Jack Pace, Director This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. P:\Permit Center\Correction Letters \2007\PG07 -290 Correction Ur #2.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DATE: January 2, 2008 PROJECT: Borders Books PERMIT NO: PG07 - 290 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) On your plans please specify size, manufacturer and model number of proposed backflow preventor and submit backflow cut sheet. Please make sure proposed backflow is a WA State Department of Health approved devise. 2) joanna Comments 2 PG07 -290 PUBLIC WORKS DEPARTMENT COMMENTS December 4, 2007 Michael Chiodini 1401 S Brentwood BI St Louis MO 63144 RE: CORRECTION LETTER #1 Plumbing/Gas Piping Application Number PG07 -290 Borders Books — 2437 Southcenter Mall Dear Mr. Chiodini, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Public Works Department. Building Department: Dave Larson, at 206 431 -3678 if you have questions regarding the attached comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenzer service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ; Bill Rambo Permit Technician encl xc: File No. PG07 -290 City of Tukwila Department of Community Development Steve Lancaster, Director P:\Pemit Center\Correction Letters \20071PG07 -290 Correction Ur #1.DOC wer Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: December 3, 2007 Project Name: Borders Books Permit #: PG07 -290 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Four gas outlets are listed on the permit application. I could not fmd any gas piping diagrams or schedule showing equipment served. Please add gas piping details as necessary to aid in our completion of this plan review or delete these from the scope of this permit and apply for a gas piping permit at a later date. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. r 2) joanna Comments 1 PG07 -290 PUBLIC WORKS DEPARTMENT COMMENTS DATE: November 14, 2007 PROJECT: Borders Books PERMIT NO: PG07 -290 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) Revise your plumbing plan per attached mark -up. Please note that gray water from sinks, floor drains, drains under garbage compactors shall be routed through the grease interceptor. DO NOT route dishwashers through the grease interceptor. If you have any plumbing design questions you may contact Mr. Mike Cusick, P.E., Public Works Senior Water and Sewer Engineer directly at (206) 431 -2441. P ERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 -290 DATE: 05 -02 -08 PROJECT NAME: BORDERS SITE ADDRESS: 2437 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: �� Buildin �'� Division P`tisWor, l& 6 , v Complete Documents/routing slip.doc 2-28-02 7) DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS R CORRECTIONS: Fire Prevention ❑ Planning Division Structural ❑ Permit Coordinator ❑ Incomplete ❑ TUES/THURS ROUTING: Please Route ROUTING: Structural Review Required ❑ No further Review Required n DUE DATE: 05 -06 -08 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVIEWER'S INITIALS: DATE: DUE DATE: 06 -03 -08 Approved Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG07 - 290 DATE: 01 -28 -08 PROJECT NAME: BORDERS BOOKS SITE ADDRESS: 2437 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 2 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division ❑ Public W 2 frOU Complete Comments: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP Structural ,,PERMIT COORD COPY Fire Prevention TERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator DUE DATE: 01-29-08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DATE: DUE DATE: 02-26-08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG07 -290 DATE: 12 -20 -07 PROJECT NAME: BORDERS BOOKS SITE ADDRESS: 2437 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # I Revision # After Permit Issued DEPART ENTS: va& Bu ding Ision Public Worlg� r K 0 Structural ❑ Permit Coordinator g ••l N1� ,q O COMPLETENESS: (Tues., Thurs.) DUE DATE: 2 -27 -07 is Complete TUES/THURS RO TING: Please Route Documents/routing slip.doc 2 -28-02 `'HERMIT WORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Incomplete Planning Division Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 01 -24 -08 n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) V Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: l • 11' DV Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW Staff Initials: �?ERI�IT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 -290 DATE: 11 -01 -07 PROJECT NAME: BORDERS BOOKS SITE ADDRESS: 9tSOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Woks • id Structural r i Fire Prevention ❑ Planning Division ❑ Permit Coordinator n C DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1 1-06-07 Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: DUE DATE: 12 -04-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) APPROVALS OR CORRECTIONS: Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Incomplete ❑ DATE: DATE: Not Applicable ❑ ❑ No further Review Required Permit Center Use Only CORRECTION LETTER MAILED: 1).- Departments issued corrections: Bldg' Fire ❑ Ping ❑ PW Staff Initials: r"'\ REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INI T) S 1 5- .1-00 FM S - iS - OK Summary of Revision: La ,r, to rc1 t o w wt evv,4 -s civ■c( wf p c1"4 es Received by: -E Ft= NZIe_e IT' REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: r j:ev$'1oo 5 PERMIT NO: C G O I ` )R 0 SITE ADDRESS: .P.- Sov' ,ce v A I,( ORIGINAL ISSUE DATE: 3 -3 REVISION LOG (please print) (please print) (please print) (please print) (please print) Date: 1'• sMsi City of Tukwila ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # 2' Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Sheet Number(s): ??Do 2 Pi-3a Paco "Cloud" or highlight all arieas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 040-140 lapplic ationslforms- applications on line\revision submittal Created: 8 -13 -2004 R rvierA Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: PG b7 - 29 RECEIVED CITv MAY 0 2 2008 PERMI1 •EN TER Project Name: harder -s _ 'J Project Address: 011 SD4T77Ce 1 t�C / 4- M4 / - 714. kL.,,, �� W4 9 1' St Contact Person: /nAlfdi 14 Pr 2,b lceve.r) Phone Number: G - 8..2. - D 7 Summary of Revision: R ei I diens Al / 7 ,".5 f /i h5 lv i .1eo�- arrc cc.rzdtcr - 4( e..4, rrl.r, r Yr `7'¢14..,,1 4,y � 2/a. s . le/ f R2 1 R (ala 11 City of Tukwila REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: i zelog Department of Comntrtnity Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 - 3665 Web site: lutp: / /wwtr.ci.lulcivilcr. Iva. us ❑ Response to Incomplete Letter # ® Response to Correction Letter # 2 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: BORDERS BOOKS Project Address: 2437 Southcenter Mall Contact Person: Michael Chiodini Plan ChecWPermit Number: PGO t -290 eirl of rotioto 1-4 JAN 282008 Phone Number: 31V -1Z5 5568 Summary of Revision: . ApGFIrD App f 1JO Gv f sNCrf s tog_ fvz RG(GibY.a'il aN/CdS. Sheet Number(s): "Cloud" or highlight all areas of revision including date of r vision Received at the City of Tukwila Permit Center by: Ak, Entered in Permits Plus on d� \ applications'. on line \revision submittal Created: 8 - 13 - 2004 Revised: REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Borders Books Project Address: 2437 Southcenter Mall Contact Person: Michael. Chlodini • Phone Number: Summary of Revision: HMSO Si l I a m b 400fay / '- 7. l 4/4/00 f Sheet Number(s): City of Tukwila \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1450 1 7 z40 . "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on — 0 7 Plan Check/Permit Number: PG07-290 Steven M Mullet, Mayor Steve Lancaster, Director • fVED rUKWILA PEC 2 0200/1 License Information License BIENEP *190B9 Licensee Name BIENER PLUMBING INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600382737 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 4033 S UNION AVE Address 2 City TACOMA County PIERCE State WA Zip 984094626 Phone 2065319261 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/29/1981 Expiration Date 9/6/2009 Suspend Date Separation Date Parent Company Previous License BIENEP *200B9 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SINGLETON, BRYAN PRESIDENT 01/31/2007 Bond Amount BIENER, ROY E PRESIDENT 01/29/1981 01/31/2007 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date DEVELOPERS STY & INDEMNITY Until Look Up a Contractor, Electri, ian or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= BIENEP* 190B9 03/03/2008 I PIPE MATERIAL MATRIX NOTE: SEE PROJECT SPECIFICATIONS FOR ALL PIPING REQUIREMENTS. LINE NUMBER PIPE USAGE PIPE LOCATION PIPE MATERIAL COMMENTS SERVICE WEIGHT HUB & SPIGOT CAST IRON WITH COMPRESSION JOINTS HUBLESS CAST IRON WITH FM STANDARD 1680 COUPLINGS DWV COPPER PIPE WITH SOLDERED JOINTS TYPE "K" COPPER WITH SILVER BRAZED JOINTS (SIL -FOS 15) TYPE "L" HARD DRAWN COPPER TUBING WITH 95 -5 SOLDERED JOINTS TYPE "L" COPPER TUBING WITH SOLDERED JOINTS SCHEDULE 40 BLACK STEEL PIPE (ASTM A53) WITH THREADED JOINTS SCHEDULE 40 BLACK STEEL PIPE (ASTM A53) WITH BUTT WELDED JOINTS STEEL PIPING AS PERMITTED BY NFPA 13 1 STORM, SANITARY & VENT PIPING UNDER GROUND • 2 STORM, SANITARY & VENT PIPING ABOVE GROUND 3 INDIRECT WASTE PIPING ABOVE GROUND 4 GREASE WASTE PIPING UNDER GROUND 5 GREASE WASTE PIPING ABOVE GROUND • • VI,' 6 DOMESTIC WATER PIPING UNDER GROUND r 7 DOMESTIC WATER PIPING ABOVE GROUND 8 CONDENSATE PIPING ABOVE GROUND 9 GAS PIPING ABOVE GROUND 2" & SMALLER 10 GAS PIPING ABOVE GROUND 410 2-1/2" & LARGER 11 SPRINKLER PIPING ABOVE GROUND .JJ I II I I II II � I 1 - � L._ II II II II II II 11 II II II II II I II 11 I II II L J 1 L —� 1 -1 4 C EX 4" RWL UP AND DN W/ CO AT BASE OF RISER —.J J L - r rL r 116m 6EE50 1 15 41 1 rr - - - -lr r IL - -_ _II IL - -_ Jr 11 11 11 11 rl - - - - 1r •h - - -- tr •L_r�1 r L_�re1 r 11 11 11 II II- HI II - - -- II L rl 1r r1 II 1E- - - -HI 1h- - - --II 11 11 11 11 11 11 11 11 rh- - - --1 1 1-- --- - -I 11 11 11 11 11 11 11 11 I }- - - -HI I1 - - - - -1f 11 1 11 1f II - - -- II IL - - - - II II_ -II Il - - - -_f 11 II 11 1 - - - - II 1 - -- -_AI II - - - -1I j I I f r ---- 7 r r IL —__- rL____1r 1 I 1 r r1 - - - --1 sr r - - --1f _NI__ __I IL___.ii 1 1 r 11 r i - - - --1 II- - - --I IL____I rL__ _11 I YI I- - - --1 rF__ 11 IL____I rL___ —I■ 1 1 1 1r rr `WPB ('W r - P1 IL - - -J 0 - - -AI 1 I Ir Ir r - -- r r I 1 =a I 1 t SCALE: 1/8"=1'-0" EX TENA R r L T CONNECTION EX COPT �F U w SANITARY & VENT OVERALL PLUMBING PLAN EX 3/4" CW 0/H EX 3" RWL B/F EX 3" ORWL B/F EX SAN EX 4" SAN B/F SEE ENLARGED CAFE PLUMBING PLANS ON SHEET P120 FOR PIPING IN THIS AREA EX 3" RD EX 3' ORD (700 SOFT) COP 1 2" SAN B/F COP, 2" CW 0/H 4" GW B/F 2 CW 0/H 4" SAN B/F EX SAN EX 4" SAN B/F - F-F L 4 GW B/F r 1 GW 1 -1/2" CWI0 /H — CW 1 L 1/2" V 0/H 0 h SEE ENLARGED PLUMBING PLAN P110 FOR PIPI AREA EX 3" ORD ( EX 3" ORD EN CUP 4- REAK ROOM ON SHEET G IN THIS 1 4° GW TO EXTERIOR GREASE S INTERCEPTOR "H ". COORDINATE LOCATION WITH SITE. 800 SQFT)�2 EX 3" V TO V EXISTING 3" VTR. - SEE ENLARGED TOILET ROOM PLUMBING PLANS ON SHEET P110 FOR PIPING IN THIS AREA PLUMBING LEGEND SYMBOLS A/F ASME B/F BALL VALVE N CFH CW — — CW — ST TYP U/G UH UR V VTR WCO WC W/ ORD RD COP EX RWL CO ORWL - -- HW - -- WH DN EWC FW FP FCO FD FS GA GI HB HD IW L G 0/H PVC ----- V RO 0 SAN SS l>C] SW DESCRIPTION ABOVE FLOOR AMERICAN SOCIETY OF MECHANICAL ENGINEERS BELOW FLOOR BALL VALVE CHECK -VALVE CONNECT TO EXISTING CUBIC FEET PER HOUR DOMESTIC COLD WATER DOMESTIC COLD WATER PIPING DOMESTIC HOT WATER DOMESTIC HOT WATER HEATER DOWN ELECTRIC WATER COOLER FILTERED WATER FIRE PROTECTION FLOOR CLEAN -OUT FLOOR DRAIN -TYPE SEE SPECIFICATION FLOOR SINK GAS COCK GAUGE GREASE INTERCEPTOR HOSE BIBB HUB DRAIN INDIRECT WASTE LAVATORY NATURAL GAS PIPING OVERHEAD PLASTIC PIPE PLUMBING VENT PIPING REVERSE OSMOSIS WATER ROUND SANITARY WASTE PIPING SERVICE SINK SHUTOFF VALVE SOFTENED WATER SQUARE FEET STORM WATER PIPING TYPICAL UNDERGROUND UNIT HEATER URINAL VENT VENT THROUGH ROOF WALL CLEAN -OUT WATER CLOSET WITH OVERFLOW ROOF DRAIN ROOF DRAIN CLEAN OUT PLUG EXISTING RAIN WATER LEADER CLEANOUT OVERFLOW RAIN WATER LEADER A\ CODED NOTES ® 1 NOT USED. / ` 2 REMOVE EXISTING 3" ROOF DRAIN AND 3" OVER FLOW ROOF DRAIN AND REPLACE WITH 3" GENERAL NOTES 1. NO PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT MAY BE SUPPORTED FROM THE SUSPENDED CEILING SYSTEM, BUT MUST BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. 6. CONTRACTOR SHALL VERIFY IF SPRINKLER HEADS UNDER STOCK SHELVING ARE REQUIRED. 2. HAZARD CLASSIFICATION OF THIS SPACE IS TO BE ORDINARY HAZARD, GROUP 2. 0.2 GPM OVER 1500 SQUARE FEET. 130 SQUARE FEET MAXIMUM COVERAGE PER SPRINKLER HEAD, AS DETERMINED BY BORDERS' INSURANCE COMPANY. 3. PENDANT SPRINKLERS IN LAY -IN CEILINGS, SOFFITS OR DRYWALL CEILINGS TO BE EQUAL TO VIKING MODEL M, SEMI RECESSED WITH MODEL E -1 CHROME FINISHED ADJUSTABLE ESCUTCHEON. UPRIGHT SPRINKLERS TO BE INSTALLED IN AREAS NOT HAVING CEILINGS. UPRIGHT SPRINKLERS TO BE VIKING MODEL M UPRIGHT. 4. THE SHELL CONTRACTOR IS PROVIDING THE WATER SERVICE TO THE BUILDING, FIRE RISER, SPRINKLER SYSTEM MAINS AND BRANCH LINES. TENANT IMPROVEMENT FIRE PROTECTION CONTRACTOR IS TO PROVIDE SWING ARMS, DROPS, AND SPRINKLER HEADS. 5. SPRINKLER HEADS MUST BE LOCATED A MIN. OF 18' AWAY FROM THE TOP OF ANY BOOK FIXTURES TO MEET CODE. 7. ALL CONCEALED PIPING SHALL BE TESTED AND PROVEN WEATHERPROOF PRIOR TO CONCEALMENT. 8. CONTRACTORS SHALL FOLLOW ALL CURRENT CODES AND BE LICENSED WITH CITY OR STATE AS REQUIRED. 9. ALL FLOOR DRAINS /CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR. 10. ALL FLOOR SINKS ARE TO BE INSTALLED EITHER FLUSH WITH FINISHED FLOOR, OR RAISED PER LOCAL CODE REQUIREMENTS. 11. ALL SPRINKLER HEADS LOCATED IN GYPBOARD CEILINGS SHALL BE CENTERED IN BETWEEN LIGHT FIXTURES UNLESS LAYOUT CONFLICTS WITH CODE REQUIREMENTS. 12. SEE SPECIFICATIONS FOR FIRE PROTECTION DESIGN AND INSTALLATION REQUIREMENTS. 13. CONTRACTOR SHALL CONTACT CIRQUA FOR WATER FILTRATION UNIT START -UP. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical O Plumbing O Gas Piping City of Tukwila BSI D u� DIVISION _ FILE CO Permit No By "�, a,hanr- REVISIONS °r ` ,.yes Shall be made to thQ scope ccf work without prior approval of Tukwila Building Division. N` TE: Revisions will require a new plan submitta and may include additional plan review fees. Plar review approval is subject to erg and osnsions. Approval of construction documents dots not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy j d conditions is ao ow edged: Date' lZ • © . City of Tukwila BUILDING DIVISION ION N0; PROJECT NO. 2007.021 INTERIOR FnISH NC. EPPRESSLY RESERVES COMMON LAW AND STATUTORY LAW GHTS AND OTHER PROPERTY SIGHTS FOR M ESE "ARCHIlEC- . AI_ WORKS" AND "TECHNICAL DOCUMENTS" AND ANY DERINTIYES "[HEREOF. M ESE DRAWINGS AND DOCUMENTS -ARE MOTTO BE REPRODUCED, CHANGED OR COPED N MY FORA OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTANNG THE EPRESS WRITTEN CONSENT OF BORDERS INC.. NOR ARE THEY TO BE ASSiGIED TO ANY PARTY WITHOUT FIRST COMING SAID YEMEN PERMISSION AND CONSENT. © COPYRIGHT PENDING ISSUED FOR: Per sumirrAL REVISION 01 REVISION 02 REVISION 4/3 RECO/ED MAY -1 2008 PERMIT CENTER 0/24/07 3124/08 4/1/08 4/23/08 SHEET TITLE OVERALL SANITARY PLUMBING PLAN STORE NO. *126 RELO TENANT IMPROVEMENT SHEET NO. P100 Architecture / Interior Design / Graphics LOUIS G. CHIODIN1 P L U M BI N G FIXTURE SCHEDULE (ALL FIXTURES & INSTALLATION PROCEDURES ARE TO MEET THE LOCAL PLUMBING CODE) P.D.I. UNITS MARK FIXTURE WASTE VENT H.W. C.W. MANE. MODEL # MODEL NAME 1 - 11 NOTES AND ACCESSORIES 33 - 60 WC-1 FLOOR MOUNTED WATER CLOSET FLUSH VALVE 4" 2" 1" KOHLER #K 4350 WELCOME VITREOUS CHINA, WATER SAVER (1.6 GPF), ELONGATED BOWL WITH 12 TOP SPUD, FLOOR MOUNTED. KOHLER #K- 4670 -C °LUSTRA" WHITE, OPEN FRONT SEAT WITH STAINLESS STEEL HINGES, LESS COVER, SLOAN GEM -2 FLUSHOMETER MODEL #111 FLUSH VALVE, TECHNICAL CONCEPTS SANITIZER PROVIDED BY BORDERS. INSTALLED BY CONTRACTOR. TECHNICAL CONCEPTS BATTERY OPERATED SENSOR TO CONTROL FLUSH VALVE PROVIDED BY BORDERS, INSTALLED BY CONTRACTOR. SEE MANUFACTURERS INFORMATION FOR CONNECTION TO SLOAN FLUSH VALVE. FLOOR BOLTS AND BOLT CAPS. ANGLE SUPPLY WITH STOP. WC-2 FLOOR MOUNTED WATER CLOSET FLUSH VALVE (ADA) 4" 2" - 1" KOHLER #K -4302 HIGHCREST VITREOUS CHINA, WATER SAVER (1.6 GPF), ELONGATED BOWL WITH 12" TOP SPUD, FLOOR MOUNTED. KOHLER #K- 4670 -C "LUSTRA" WHITE, OPEN FRONT SEAT WITH STAINLESS STEEL HINGES, LESS COVER, SLOAN "GEM -2" FLUSHOMETER MODEL #111 FLUSH VALVE, TECHNICAL CONCEPTS SANITIZER PROVIDED BY BORDERS. INSTALLED BY CONTRACTOR. TECHNICAL CONCEPTS BATTERY OPERATED SENSOR TO CONTROL FLUSH VALVE PROVIDED BY BORDERS, INSTALLED BY CONTRACTOR. SEE MANUFACTURERS INFORMATION FOR CONNECTION TO SLOAN FLUSH VALVE, FLOOR BOLTS AND BOLT CAPS. ANGLE SUPPLY WITH STOP. FIXTURES TO BE FURNISHED AND INSTALLED IN ACCORDANCE WITH ADA AND LOCAL BARRIER FREE REQUIREMENTS 2 L-1 COUNTER LAVATORY 12" 12" 211 2 KOHLER #K 2602 S RHYTHM CHROME - PLATED LAVATORY SUPPLY ASSEMBLIES WITH LOOSE KEY STOPS. CHROME- PLATED WHEELCHAIR TAIL - PIECE. CHROME PLATED GRID STRAINER. TECHNICAL CONCEPTS BATTERY OPERATED AUTOMATIC FAUCET PROVIDED BY BORDERS, INSTALLED BY CONTRACTOR. PROVIDE TRAP AND SUPPLY PROTECTIVE INSULATOR EQUAL TO "INSUL GUARD" VANDAL RESISTANT PVC. MOUNT AT ELEVATIONS INDICATED ON ARCHITECTURAL DRAWINGS. UR -1 WALL HUNG URINAL 2 „ 1Y " 4 " KOHLER #K- 4989 -T FRESHMAN /t / \ TECHNICAL CONCEPTS SANITIZER PROVIDED BY BORDERS. INSTALLED BY CONTRACTOR. SEE MANUFACTURERS INFORMATION FOR CONNECTION TO SLOAN FLUSH VALVE. SLOAN GEM-2° FLUSHOMETER MODEL NO. 180 -1 FLUSH VALVE. TECHNICAL CONCEPTS BATTERY OPERATED SENSOR TO CONTROL FLUSH VALVE PROVIDED BY BORDERS, INSTALLED BY CONTRACTOR. SEE MANUFACTURERS INFORMATION FOR CONNECTION TO SLOAN FLUSH VALVE. FIXTURES TO BE FURNISHED AND INSTALLED IN ACCORDANCE WITH ADA AND LOCAL BARRIER FREE REQUIREMENTS. 2 FD -1 FLOOR DRAIN SEE PLAN 2" J.R. SMITH 2005 / ' PROVIDE WITH MINIMUM 4" DEEP SEAL TRAP, AND OUTLET AS REQUIRED BY PIPING MATERIAL. _ FD -2 FUNNEL FLOOR DRAIN SEE PLAN - - 2 J.R. SMITH 3500 SERIES - PROVIDE WITH MINIMUM 4" DEEP SEAL TRAP, ADJUSTABLE STRAINER HEAD WITH SECURED SQUARE HOLE GRATE AND FUNNEL ATTACHED. OUTLET AS REQUIRED BY PIPING MATERIAL. FCO FLOOR CLEANOUT - - - J.R. SMITH 4000 SERIES - ADJUSTABLE CLEANOUT NICKEL BRONZE OR CHROME FINISH, IF FLOORS ARE TILED, OR TERRAllO. USE RECESSED TOP IF FLOORS ARE CARPETED. CLEANOUTS ARE TO BE FLUSH WITH FINISHED FLOOR. WCO WALL CLEANOUT - J.R. SMITH 4400 SERIES - THREADED CLEANOUT PLUG WITH FERRULE AND ROUND ACCESS COVER NICKEL BRONZE OR CHROME FINISH. EWC -1 ELECTRIC WATER COOLER 12" 12" - 2" ELKAY ERPBM28K 3 - THE VANDAL RESISTANT, TWO LEVEL WHEEL CHAIR ACCESS UNIT, TWO FOUNTAINS WITH ONE AT WHEELCHAIR HEIGHT AND ONE AT CONVENTIONAL HEIGHT. ADA COMPLIANT FRONT PUSH BAR, 8.0 GPH, 1/5 HP, 120 VOLT FOR EACH UNIT. MOUNT LOWER UNIT WITH RIM AT 34" AFF. COLOR TO BE SELECTED BY ARCHITECT FROM STANDARD COLOR CHART. 8 -1 LOUNGE SINK 1 I/2" 12" 2" 2" ELKAY #LRAD -2521 LUSTERTONE CHROME- PLATED LAVATORY SUPPLY ASSEMBLIES WITH LOOSE KEY STOPS. CHROME- PLATED TUBULAR "P" TRAP. KOHLER #K15171 8 1/2" SWING SPOUT, SINGLE LEVER FAUCET. ELKAY #LK -18 DRAIN WITH PERFORATED GRATE SS -1 FLOOR MOUNTED SERVICE SINK 3 12 2" )/' FIAT MSB -2424 - MOLDED STONE FLOOR MOUNTED SINK. PROVIDE WITH FIAT #83O -AA S.S. FAUCET WITH VACUUM BREAKER, HOSE END, STOPS, AND 30" HOSE W/ HOSE BRACKET ALONG WITH FIAT #1453.BB FLAT STRAINER. HB HOSE BIBB _ _ - Y WATTS BD -QT - FORGED BRASS BODY QUARTER TURN BALL VALVE, 1 /2" WATER CONNECTION, 3/4" HOSE CONNECTION TO BE SUPPLIED WITH WATTS VACUUM BREAKER MODEL NUMBER 8A, AND WALL ESCUTCHEON. WH -2 WATER HEATER - - m 4" IN SINK ERATOR W -152 2 -1/2 GALLON WATER HEATER SHALL BE BRONZE LONG -LIFE STORAGE TANK WITH SCREW -IN COPPER HEATING ELEMENT. 2-', GALLON STORAGE, 1500 WATTS, 120V /1PH, 150 PSI OPERATING, 8.6 GPH RECOVERY @ 8D° RISE, 3 /" PRESSURE RELIEF CONNECTION. INSULATED WITH EXPANDED POLYSTRYENE, ONE YEAR FULL WARRANTY, DRAIN PROVIDED FOR MAINTENANCE. STANDARD P.D.I. WH 201 WATER HAMMER ARRESTER SCHEDULE P.D.I. UNITS S o O a o Q a FIXTURE UNITS 1 - 3 1 - 11 12 - 32 33 - 60 61 - 113 114 - 154 155 - 330 2" SAN PIPING B /F. SEE SHEET P100 FOR S CONTINUATION OF PIPING. NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDIT nN OR11ATION. 2" CW PIPING OVERHEAD. SEE SHEET P100 FOR CONTINUATION OF PIPING. NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. 2" CW PIPING OVERHEAD. SEE SHEET P100 FOR CONTINUATION OF PIPING. ENLARGED BREAK ROOM SANITARY PLUMBING PLANS SCALE: 1l4" =1' -0" - U 1 SCALE: 114" =1. -0" 2" SAN B/F 2" HUB DRAIN cw 3/4" 0/H WH -2 MOUNT TO BACK OF CABINET BELOW 5S1 S -1 ENLARGED BREAK ROOM DOMESTIC WATER PLUMBING PLANS 1Tl r 3/4" CW DN IN WALL 1/2" TO &--WH 2 1 1/2" V O/H 1' 1 -1/2" VENT PIPING 0 /H. Stt UUNUINUAIIUN Uf PIPING ON SHEET P100. -- O 3/4" HW PIPING OVERHEAD. SEE SHEET P120 FOR 5 CONTINUATION OF PIPING. 2" CW PIPING OVERHEAD. SEE SHEET P100 FOR CONTINUATION OF PIPING. EWC -1 L NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. SCALE: 114" =1' -0" 1 /� TO WC-2 L -1 1 —1- LOCATE VALVES ABOVE ACCESSIBLE CEILING UR -1 L -1 L -1 WC WC-2 CW ENLARGED TOILET ROOMS DOMESTIC WATER PLUMBING PLANS SS -1 1 /2" CW & HW DN WITHIN WALL TO SS -1 1/2" WATTS 008PCQT SERIES SPILL RESISTANT, ANTI - SIPHON VACUUM BREAKER 1/2' CW DN WITHIN WALL TO HB 2" VENT PIPING 0 /H. SEE SHEET P120 FOR 5 CONTINUATION OF PIPING. 4" SAN PIPING B /F. SEE SHEET FOR 5 CONTINUATION OF PIPING. L NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. EWC -1 ENLARGED TOILET ROOMS SANITARY PLUMBING PLANS SCALE: 1l4" =1' -0" 11 WC-2 L -1 L -1 r 4" SAN B/F v 1 -1/2" V 0/H ® Fc� 3" V O/H ( UR -1 L -1 L -1 1 -1/2" VENT PIPING 0 /H. SEE CONTINUATION OF PIPING ON SHEET P100. B/F / u /WC 1i WC-1 We -2 FD-1 H H 4 4 4 b SS FD -1 2" V 0/H REVISION X0,1 ?&O7' 2`l0 3 " V 0/H EXISTING 3" VENT PIPING - -5 O /H. COORDINATE EXACT LOCATION WITH SITE. PROJECT NO. 2007.021 INTERIOR FINISH BORDERS INC. E>aRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPIRIGHTS ANC OTHER PROPERTY RIGHTS FOR THESE 'ARCHITECTURAL WORKS" AND "TECHNICAL DOCUMENTS" AND ANY DERIVRIVES THEREOF. THEE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED. QiANGED OR COPED N ANY FORM CR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST °STAVING THE ET'RESS WRITTEN CONSENT CF BORDERS INC.. NOR ARE THEY ID BE ASSIGNED TO ANY PARTY WITHOUT FIRST °STARING SAID WRITTEN PERMISSION AND CONSENT. © COPIRIGHT PENDING Z 0 C'3 ISSUED FOR: PERMIT SUBMITTAL REVISION ti REVISION REVISION 42 REV ION IV 3/24/08 3/24/08 4tw08 4/23/08 MAY -1 2000 PERMIT CENTER SHEET TITLE TOILET ROOM & BREAK ROOM PLUMBING PLANS STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. P110 LOUIS G. CHIODINI Architecture / Interior Design / Graphics 1401 South Brentwood Blvd. / Suite 425 / St Louis, Missouri 63144 314-725-5588 / Fox 314-725-4347 B o RD E R s 4 SOUTHCENTER MALL PLUMBING FIXTURE SCHEDULE (ALL FIXTURES & INSTALLATION PROCEDURES ARE TO MEET THE LOCAL PLUMBING CODE) MARK FIXTURE WASTE VENT H.W. C.W. MANF. MODEL # MODEL NAME NOTES AND ACCESSORIES SS -1 FLOOR MOUNTED SERVICE SINK 3" 1%" y2" j" FIAT MSB -2424 - MOLDED STONE FLOOR MOUNTED SINK. PROVIDE WITH FIAT #830 -AA S.S. FAUCET WITH VACUUM BREAKER, HOSE END, STOPS, AND 30" HOSE W/ HOSE BRACKET ALONG WITH FIAT #1453.BB FLAT ER . 1 FD -1 FLOOR DRAIN SEE PLAN - - W" J.R. SMITH 2005 - PROVID WITH MINIMUM 4" DEEP SEAL TRAP, AND OUTLET AS REQUIRED BY PIPING MATERIAL. FS -1 FLOOR SINK SEE PLAN SEE PLAN - - J.R. SMITH 3100 SERIES - FLOOR SINK IS TO BE 12 "X12 ". PROVIDE DEEP SEAL TRAP WITH FLOOR SINK. SEDIMENT BUCKET, NICKEL BRONZE TOP, 1/2 GRATE, AND OUTLET AS REQUIRED BY PIPING MATERIAL. FD -2 FUNNEL FLOOR DRAIN SEE PLAN _ _ _ J.R. SMITH 3500 SERIES - PROVIDE WITH MINIMUM 4" DEEP SEAL TRAP, ADJUSTABLE STRAINER HEAD WITH SECURED SQUARE HOLE GRATE AND FUNNEL ATTACHED. OUTLET AS REQUIRED BY PIPING MATERIAL. FCO FLOOR CLEANOUT WATER FILTER (C SYSTEM) 1/2" 3/4" J.R. SMITH 4000 SERIES 1 ADJUSTABLE CLEANOUT NICKEL BRONZE OR CHROME FINISH, IF FLOORS ARE TILED, OR TERRAllO. USE RECESSED TOP IF FLOORS ARE CARPETED. CLEANOUTS ARE TO BE FLUSH WITH FINISHED FLOOR. HB HOSE BIBB (3) 1 -1 /2" - (E141) T WATTS BD QT 1/2" FORGED BRASS BODY QUARTER TURN BALL VALVE, 1/2" WATER CONNECTION, 3/4" HOSE CONNECTION TO BE SUPPLIED WITH WATTS VACUUM BREAKER MODEL NUMBER 8A, AND WALL ESCUTCHEON. WCO WALL CLEANOUT 1 HAND SINK - 2 HOLE 1/2" 1/2" J.R. SMITH 4400 SERIES (E144) CLEANOUT PLUG WITH FERRULE AND ROUND ACCESS COVER NICKEL BRONZE OR CHROME FINISH. WH -1 WATER HEATER 1/2' - 1X" 1X" A.O. SMITH DVE -80 -45 - GLASS -LINED WATER HEATER 80 GALLON STORAGE, 45 KW INPUT @ 480 VOLT /3 PHASE, 184 GPH RECOVERY @ 100 DEGREE F TEMPERATURE RISE. HEATER WARRANTY SHALL BE 3 YEARS. FURNISH HEATER WITH APPROPRIATE WATTS REGULATOR TEMPERATURE AND PRESSURE (T &P) RELIEF VALVE ALONG WITH A VACUUM BREAKER VALVE. FACTORY PROVIDED WATER HEATER DRAIN PAN. SAFEWASTE FULLSIZE T &P RELIEF PIPE AND 3/4" DRAIN PAN DRAIN TO NEAREST MOP SINK. ALL SAFEWASTE PIPING TO BE CONCEALED. EXPANSION TANK - AMTROL THERMAL EXPANSION ABSORBER MODEL ST -12, 6.4 MAXIMUM ACCEPTED GALLONS. EQUIPMENT SCHEDULE TAG QTY. DESCRIPTION COLD HOT WASTE REMARKS (E100) 1 ESPRESSO MACHINE - SBC 3/8" - 3/4" ` 1,2,3,6 (f110) 1 ICE - BIN - DROP IN - - (2) 1 1/2" 3 ® 1 DIPPERWELL ASSEMBLY 1/2 - 1 1/2" 3 ® 1 ICE MACHINE - 500 LB 3/8" - 3/4" & 1 -3/8" 1,3 ® 1 DISHWASHER - 3/4" 3J4" 3 (E136) 1 WATER FILTER (C SYSTEM) 1/2" 3/4" 3,5 (E139) 1 3 COMPARTMENT SINK 1/2" 1/2" (3) 1 -1 /2" 3 (E141) 1 WALL MOUNTED HANDSINK WITH FAUCET 1/2" 1/2" 1 1/2' (E143) 1 HAND SINK - 2 HOLE 1/2" 1/2" 1 1/2" (E144) 1 WORK SINK 1/2" 1/2' 1 1/2" (E150i) 1 CARBONATED SODA SYSTEM 3 / 8 " - 1/2" 1,2,3,7 (E166) 1 COFFEE BREWER - SBC 1 /4" - - 1,6 ® 1 FAUCET GLASS FILLER 1/2' 1/2 1 -1/2" 1,3 REMARKS: 5. REQUIRES 40 TO 90 PSI WATER SUPPLY. ADD PRESSURE REDUCING VALVE OR BOOSTER PUMP AS 1. CONNECT TO FILTER SYSTEM REQUIRED. 2. REQUIRES MIN. 30 PSI WATER SUPPLY 6. 1/2" SUPPLY W/ 36" BRAIDED STAINLESS STEEL 3. INDIRECT WASTE HOSE. 4. NOT USED 7. BACKFLOW PREVENTER. SEE SHEET P130 FOR DETAILS. A\ AS, GENERAL NOTES: 1. ALL THE EQUIPMENT PROVIDED BY THE F.S.E.C. SHALL BE DELIVERED TO THE JOB AND SET -IN- PLACE, READY FOR FINAL CONNECTIONS. PLUMBING CONTRACTOR SHALL PROVIDE FINAL CONNECTIONS, AND ALL MATERIALS REQUIRED FOR CONNECTIONS, IN ACCORDANCE TO LOCAL CODES. 2. IT IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO VERIFY EXISTING UTILITY REQUIREMENTS AND USE WITH NEW LAYOUT AND EQUIPMENT REQUIREMENTS. 3. ALL DIMENSIONS GIVEN ARE FROM FINISHED SURFACES (WALLS, FLOORS, ETC.) TO FINISHED SURFACE AND /OR CENTER OF UTILITY SERVICE. 4. UNDER NO CIRCUMSTANCE ARE THE COUNTER TOPS OR EQUIPMENT TO BE WALKED ON AT ANY TIME BY ANY TRADES PERSON. 5. PLUMBING CONTRACTOR TO PROVIDE WATTS #SD -3 BACK FLOW PREVENTOR FOR CARBONATOR EQUIPMENT. REFER TO MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. REFER TO PLANS FOR CONNECTION SIZE. 6. SEE EQUIPMENT SCHEDULE ON DWG FSE -1 FOR ADDITIONAL INFORMATION ON KITCHEN EQUIPMENT. 7. PROVIDE QUARTER TURN STOPS FOR ALL SUPPLY CONNECTIONS FOR KITCHEN EQUIPMENT. 8. ALL RO / FW PIPING TO BE COPPER SIMILAR TO DOMESTIC WATER PIPING. SEE SPECIFICATIONS. STANDARD P.D.I. WH 201 WATER HAMMER ARRESTER SCHEDULE P.D.T. UNITS ® 0A ® C® ® ® FO FIXTURE UNITS 1 - 3 1 - 11 12 - 32 33 - 60 61 - 113 114 - 154 155 - 330 i WA L NOTES: SCALE: NONE AFE WTE pi �pRESSN R F N N ER +22 "H MOUNTED ON SIDE PANEL OF CORNER CABINET SCALE: 1!4 " =1' -0" TO FIO s i zE S INK SEE EQUIPMENT SCHEDULE FOR CONNECTION SIZES. NOTE: RUN WATER LINES ALONG INSIDE OF CABINETS & THROUGH '' / CASEWORK TO POINT OF FILTERED CW FOR E100 USE ESPRESSO MACHINE +16 "H UNFILTERED CW FOR E117 DIPPERWELL +22 "H CD c 5' -11" 7 4 1 ENLARGED CAFE DIMENSIONAL PLAN /4' G1i ' Drain 6 °H for rk Sink Water + 6 "water 18 °Water 8 "Drain 16" Water 18 "Drain 18 "Water in CIRQUA C SYSTEM & WATER HEATER PIPING DETAIL '-0' I I SS -1 L 4" SAN B/F & 4" OW B /F. SEE SHEET P100 FOR CONTINUATION OF PIPING. SCALE: 114 " =1' -0" SEE R ISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. E136 FS -1 WH - I — J RO DN WITH IN LINES IN CASE 100, E117 & 511 1 -1/2" CW 0/H ,/4" WATTS 008PCQT SERBS PILL RESISTANT, \\ fNTI- SIPHON VACUUM BREAKER SS -1 WCQ I � ENLARGED CAFE SANITARY PLAN F 7 L F 7 L FD -1 OD 2" VENT 0 /H. SEE SHEET P110 —5 FOR CONTINUATION OF PIPING. 1/ " HW AND CW DOWN TO LEONARD ERMOST TIC MI ING VALVES ON E141 & E144. SE: SHEET P200 FOR DETAILS. PR RO SD -3 BACKFLOW VENTER WITH VENT. INSTALL PEF UFACTURER'S RECCOMENDATION TE WASTE LINE TO FD -2. E143 SEE PIPING DETAIL ON THIS SHEET FO CONTINUATION OF PIPING T THIS AREA. — 1/2" CW IN WITH IN WALL TO HB 1/2° CW & HW DN WITH IN WALL TO SS -1 1/2' WATTS 008PCQT SERIES SPILL RESISTANT, ANTI- ST VACUUM RRFAKER NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. SCALE: 114 " =1'-0" 1 -1/2' CW 0 /H. SEE SHEET P100 FOR CONTINUATION OF PIPING. L ENLARGED CAFE DOMESTIC WATER PLAN J 3/4" HW 0 /H. SEE SHEET P110 FOR CONTINUATION OF PIPING. /1\ r REVISION N 1 P&O7 290 PROJECT NO. 2007.021 INTERIOR FLASH BORDERS INC. IDPRESSLY RESERVES HIS COMMON LAW MD STATUTORY LAW COPYPoGHTS AND OTHER PROPERTY RIGHTS FOR 1)ESE "ARCHITECTURAL WORKS" AD "TECHNICAL DOCUMENTS AND ANY DERMTIVE5 THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED. CHANGED OR COPED N ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE DRESS WRITTEN CONSENT OF BORDERS INC.. NCR ARE 1EEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINNG SAID WRITTEN PERMISSION AND CONSENT. © COPYRIGHT PENDING 1 J 0 • 2 11.1 Co z >. w 1— —1 I o �c CO D 1— EXPIRES 7/Z 09 1 ISSUED FOR: PEWIT SUBIRTTAL REVISION 111 REVISION 12 REVISION WS PECEIVED MAY —1 2008 PERMIT CENTEF 0/24/07 a/24 /O8 4/14/08 4/23/08 SHEET TITLE ENLARGED CAFE PLUMBING PLANS STORE NO. #126 RELO TENANTINRROVEMENT SHEET NO. P120 Z CE o g S N " 1 1 /2h /gh 3/0 HW 3 1 114° 0 - 1/ . RD R HEAD DOMESTIC WATER PIPING. Rs ri ss'■ SEE SHEET P100 FOR CONTINUATION. 3/4' OVE 1 1 `� • . l4° 4 1. 1 14h � ' 0 R 8� �8P 1.1 14 h 1114 _ ., VACUUM B r qNp �SER %%- . 1 / „ ILL : 40 /” I �.� -� I h %%1 `• 314+ 0 It uip I I 1 1 1 1 / 2 i \ 1I 1 1 11 I Ow CA FE 5` 012 .. 3' REFER TO SHEET P120 FOR CIROUA C SYSTEM & WATER HEATER PIPING DETAIL 2° 01" �i V' 2° �� Ci ill f � I 1 1+ 1 ON V _i �� '1.11 1. � � 1 12 01H r..- F 4 °B 1. ' _' . 441E 1 0. 3' 1,1/2 no���� BW 1. 1 v1 N � T 2 1 � E R FOR � � / r I r `` \ \$ f 4 B/F �,� B \ 4 " B I T 2 B \ `�-, F` ,� ?r11(t 1 SCALE: NONE 1.1 0 n �I 1 I 1 Ro_ C AF �`- I / ! X1. / 01 " I �. I 1 IE� I 1. r 3' CAFE DOMESTIC WATER, SANITARY & VENT PIPING RISER DIAGRAMS AS H spE pF F Ro� R EST 1 -i/2" OVER HEAD DOMESTIC WATER PIPING. qI�R g SEE SHEET P100 FOR CONTINUATION. �Riq TYp NG 3/ /- 1 1 12° RO 1/2° cW G� 1 I Wq 112 c w 1/2° R0 � 1/2, 3/4' OVER HEAD DOMESTIC WATER PIPING. V AC � S T gp Cgr � / 0 1" SEE SHEET P110 FOR CONTINUATIDN. ��M R r �Ep 5p'1 112, 1 I -. I` I 4^ /2 I q+ l" 3 o 11 2° 3/ "W .� 1° 0/H 0 /H I 1 1 �w I .I`` ��� ,- I �' .III KELp 2. 3 AAp TO 0 TTS #50"0.0.1 A pM VENT EVE 4 FROM AO OTE 2° VENT PIPING OVER HEAD FROM CAFE, SEE SHEET P110 FOR CONTINUATION. 4" GREASE WASTE PIPING BELOW FLOOR FROM CAFE. SEE SHEET P100 FOR CONTINUATION. 4" SANITARY PIPING BELOW FLOOR FROM CAFE. SEE SHEET P100 FOR CONTINUATION. We 4" I 2' VENT PIPING OVER HEAD FROM CAFE. SEE SHEET P120 FOR CONTINUATION. n0 �`� B 0/" 2 f... 211 %. 2 0111 . r i / " .14 11/2h 2 a � I � . r 2° '12° UR F` k `k 2° l. 3/ N ` > - \ 2 3+ 0 / " . �� 1/ ' 3/4° OVER HEAD DOMESTIC HOT WATER PIPING. SEE SHEET P120 FOR CONTINUATION. 1.112 OM B/F 2° SANITARY PIPING BELOW FLOOR FROM BREAK ROOM. SEE SHEET P100 FOR CONTINUATION. 2' OVER HEAD DOMESTIC WATER PIPING. SEE SHEET P100 FOR CONTINUATION. of of 1 SS. TOILET ROOM DOMESTIC WATER, SANITARY & VENT PIPING RISER DIAGRAMS SCALE: NONE 01" 4° SANITARY PIPING BELOW FLOOR FROM TOILET ROOMS. SEE SHEET P100 FOR CONTINUATION. r SCALE: NONE 1.1/2° A\ �, do 30 �� �� 0 / " \/ � - 30 010 1 - 1/2' VENT PIPING OVER HEAD FROM BREAK ROOM. SEE CONTINUATION OF PIPING ON THIS SHEET. EMPLOYEE BREAK ROOM DOMESTIC WATER SANITARY & VENT PIPING RISER DIAGRAMS C ` 3/4' °III ` \ 1 -1/2' VENT PIPING OVER HEAD FROM BREAK ROOM. SEE CONTINUATION OF PIPING ON THIS SHEET. E GO 12° 0/H N 3/4" OVER HEAD DOMESTIC WATER PIPING TO BREAK ROOM. SEE SHEET P110 FOR CONTINUATION. A O/A VAL LI o IN S P 31$ TO 114001 TUA 10 GpA,4 LI ON 1/ ° .` .� 112 !2h 3" VENT PIPING 0/H TO EXIST 3' PIPING O /H. SEE SHEET P100 FOR CONTINUATION. 1 i. NEAEOS0.1- 0 G 0 A WA AAES AO REVISION N0: ?&o1 2c?o PROJECT NO. 2007.021 INTERIOR FINISH BORDERS INC. DCPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTTER PROPERTY RIGHTS FOR 'THESE 'ARCHITECTURAL WORKS" AND "TECHNICAL DOCUMENTS AND ANY DERMi1VES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED, CHANGED OR COPED N ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTANING THE EXPRESS WRITTEN CONSENT OF BORDERS NC., NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAD WRITTEN PERMISSION AND CONSENT. © COPYRIGHT PENDING ISSUED FOR: PERMIT SUBMITTAL REVISION *1 REVISION #2 REVISION *3 CEW E MAY —1 2008 PERMIT CENTE1 9/24/07 3/24/08 4/14/08 4/23/08 SHEET TITLE PLUMBING PIPING DIAGRAMS STORE NO. *126 RELO TENANT IMPROVEMENT SHEET NO. P130 FINISHED FLOOR FLOOR SLAB DIAMETER REFER TO PLAN PLACE HEAD IN CENTER OF TILE ACOUSTIC TILE TYPE 1 CENTER THE HEAD IN THE 24" x 24" SECTION OF THE TILE ACOUSTIC TILE TYPE 2 & 3 FLOOR SINK DETAIL SCALE: NONE • • 4" DEEP SEAL TRAP SPRINKLER HEAD LOCATIONS DETAIL SCALE: NONE PRECISION PLUMBING PRODUCTS MODEL 50R TRAP PRIMER VALVE %" SOFT COPPER PRIMER LINES FLOOR y2 TO OTHER FLOOR DRAINS SCALE: NONE • PLACE HEAD IN CENTER OF TILE ACOUSTIC TILE TYPE 2 & 3 STEEL GRATE TOP FLUSH WITH FINISHED FLOOR NOTE: PROVIDE WITH CHROME ESCHUTCHEONS LESS OTHERWISE NOTED NEAREST COLD WATER SOURCE 4 MIN, 1 MAX DISTRIBUTION UNIT AS REQUIRED FOR SERVING MULTIPLE TRAPS -CONN TO TRAP PRIMER VALVE PRIMER PIPING CONCEALED IN WALL 4" DEEP SEAL TRAP TRAP PRIMER DETAIL THIS SIDE REPRESENTS A DIFFUSER OR LIGHT ACCESSIBLE LAY -IN CEILING (A.C.T. /GRID) WHERE APPLICABLE FLOOR DRAIN CEILING SPACE TO EXISTING EXTERIOR GREASE INTERCEPTOR DISHMACHINE CONNECT TO WASTE LINE WITH AIR GAP SEE DETAIL THIS SHEET. c FLOOR SINK 3 COMPARTMENT SINK AND DISHWASHER DETAIL SCALE: NONE THREE COMPARTMENT SINK FINISHED FLOOR 4" GW B/F TO EXISTING EXTERIOR GREASE INTERCEPTOR. 4° HW ROUGH -IN WITH 4" BALL VALVE, LINE STRAINER, WATER PRESSURE REGULATOR AND TRANSITION TO 4" MALE GARDEN HOSE FITTING CONN TO DISHMACHINES 4° FEMALE GARDEN HOSE FITTING. ESCUTCHEON WATER HAMMER ARRESTER + 0 an 6' LONG FILL HOSE UPPLIED W/ MACHINE c SEE SHEET P120 FOR CONTINUATION. 6' LONG DRAIN HOSE SUPPLIED W/ MACHINE TERMINATES W 4" MPT FITTING TERMINATE 3 HARD COPPER PIPE W/ 4" FPT FITTING AND CONNECT TO MFGR. DRAIN HOSE. 4" HARD COPPER PIPE. CONNECT TO AIR GAP FITTING JR SMITH #3950T AIR GAP FITTING W/ 1 - % ° THREADED OUTLET CLAMP TO WALL ESCUTCHEON HANGER ROD LOCKING NUT SUPPORT NUT HEAVY DUTY CLEVIS HANGER. MATERIAL TO MATCH PIPE. PIPE GENERAL NOTES: 1. PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES. DRAIN AND FILL LINE CONFIGURATIONS VARY, SOME METHODS ARE SHOWN ON THIS DRAWING. DISHWASHER CONNECTION DETAIL SCALE: NONE CLEVIS HANGER SINGLE HORIZONTAL RUNS NO VAPOR BARRIER INSULATION PIPE SUPPORT DETAIL SCALE: NONE HANGER ROD LOCKING NUT SUPPORT NUT CLEVIS HANGER SINGLE HORIZONTAL RUNS WITH VAPOR BARRIER INSULATION SCALE: NTS 3/8" TW 3/8" HW LEONARD MODEL 108 -BP THERMOSTATIC MIXING VALVE WITH BYPASS 3/8" CW 318" CW THERMOSTATIC MIXING VALVE DETAIL HEAVY DUTY CLEVIS HANGER. MATERIAL TO MATCH PIPE. VAPOR BARRIER PIPE INSULATION 16 GA. ZINC COATED SHEET STEEL SADDLE 8° LONG MINIMUM REVISION NOE PG07- ;i'jo PROJECT NO. 2007.021 INTERIOR FINISH BORDERS NC. DCPRESSLY RESERI ES HIS COWpN LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE 'ARCHITECTURAL WORKS" AND 'TECHNICAL DOCUMENTS. AND ANY DERPAT1VES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED. CHANGED OR COPED IN ANY FORM OR MANNER WHATSOEVER FCR ANY USE WITHOUT FIRST OBTANNG THE EXPRESS %RIYIEN CONSENT OF BORDERS NC.. NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT F1RST OBTAINING SAD WRITTEN PERMISSION MD CONSENT. p COPYRIGHT PENDNG liDaNRES 7/2 /off' 1 ISSUED FOR: PERMIT SUBMNTrAL REVISION *1 9/24/07 8/24/08 I MAY -1 2008 PERMIT CENTER SHEET TITLE PLUMBING DETAILS AND SCHEDULES STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. P200 PIPE MATERIAL MATRIX NOTE: SEE PROJECT SPECIFICATIONS FOR ALL PIPING REQUIREMENTS. LINE NUMBER 1 I i I PIPE USAGE PIPE MATERIAL COMMENTS PIPE LOCATION SERVICE WEIGHT HUB & SPIGOT CAST IRON WITH COMPRESSION JOINTS 1 HUBLESS CAST IRON WITH FM STANDARD 1680 COUPLINGS DWV COPPER PIPE WITH SOLDERED JOINTS TYPE "K" COPPER WITH SILVER BRAZED JOINTS (SIL•FOS 15) TYPE "L" HARD DRAWN COPPER TUBING WITH 95 -5 SOLDERED JOINTS TYPE "L" COPPER TUBING WITH SOLDERED JOINTS SCHEDULE 40 BLACK STEEL PIPE (ASTM A53) WITH THREADED JOINTS SCHEDULE 40 BLACK STEEL PIPE (ASTM A53) WITH BUTT WELDED JOINTS i STEEL PIPING AS PERMITTED BY NFPA 13 STORM, SANITARY & VENT PIPING UNDER GROUND 2 STORM, SANITARY & VENT PIPING ABOVE GROUND J 3 INDIRECT WASTE PIPING ABOVE GROUND • 4 GREASE WASTE PIPING UNDER GROUND • 5 GREASE WASTE PIPING ABOVE GROUND 6 I DOMESTIC WATER PIPING UNDER GROUND 7 DOMESTIC WATER PIPING ABOVE GROUND B CONDENSATE PIPING ABOVE GROUND 9 GAS PIPING ABOVE GROUND 2 & SMALLER 10 GAS PIPING ABOVE GROUND • 2-1/2 & LARGER 11 SPRINKLER PIPING ABOVE GROUND 1 LL L4 nr II L- L -. II II II II 11 1h r t n / � 11 2 I EX 4° RWL UP AND DN W/ CO AY BASE OF RISER -. 1 I Ite Ir---- 1rIli --- 11 11._____11 1 11 - - - -J1 1 1 1 1 II- -II I1 - - -- 11 IL_OHPJIIIL_ev,E_1 1 1 1 1 II- - - -1 II- - - --1I 1 1 1° 1 1 1 1 1 1 1 1 1 1 1 1111 1 11 II 111 II 1 1 1 11 1 1 1 1 11------Ill 1 1 1 1 1 1 1111 - - -1 I I I 1 I - - --11 1 1 1 1 1 1 11 - - -- ii II1 - - - -1I II 11 /1 _ DN 1 1 1 I I - - - --I ■ 1 1 ■ 1 X 1 1 1 EX 3/4" CW ON TO EX HB SCALE: 3/32" =1' -0" T n EX TENANT CONNECTION ILLft r SANITARY & VENT OVERALL PLUMBING PLAN EX COP t1 I I EX HB U x w 3/4" 0/H EX 3" RWL B/F EX 3" ORWL B/F SEE ENLARGED CAFE PLUMBING PLANS ON SHEET P120 FOR PIPING IN THIS 1 EX 3" RD EX 3" ORD (700 SOFT) 1 1 5 i L 2" BIF COP 4 4" B/F 4" B/F SAN 2° 0/H 2'0/H 4" B/F EX SAN S CW L L EX GOP SEE ENLARGED BREAK ROOM PLUMBING PLANS ON SHEET P110 FOR PIPING IN THIS AREA V EX 3" ORD (B00 SOFT) -EX 3° ORD 4° GW TO EXTERIOR GREASE S INTERCEPTOR "H ". COORDINATE LOCATION WITH SITE. Ex 3" V TO EXISTING 3" VTR. SEE ENLARGED TOILET ROOM PLUMBING PLANS ON SHEET P110 FOR PIPING IN THIS AREA PLUMBING LEGEND SYMBOLS A/F ASME B/F BALL VALVE N4 e CFH CW CW WH DN EWC FW FP FCO FD FS GA GI HB HD IW L G 0/H PVC RO 0 SAN ss SW ST TYP U/G UH UR v VTR WCO WC W/ DESCRIPTION ABOVE FLOOR AMERICAN SOCIETY OF MECHANICAL ENGINEERS BELOW FLOOR BALL VALVE CHECK -VALVE CONNECT TO EXISTING CUBIC FEET PER HOUR DOMESTIC COLD WATER DOMESTIC COLD WATER PIPING DOMESTIC HOT WATER DOMESTIC HOT WATER HEATER DOWN ELECTRIC WATER COOLER FILTE9ED WATER FIRE PROTECTION FLOOR CLEAN -OUT FLOOR DRAIN -TYPE SEE SPECIFICATION FLOOR SINK GAS COCK GAUGE GREASE INTERCEPTOR HOSE BIBB HUB DRAIN INDIRECT WASTE LAVATORY NATURAL GAS PIPING OVERHEAD PLASTIC PIPE PLUMBING VENT PIPING REVERSE OSMOSIS WATER ROUND SANITARY WASTE PIPING SERVICE SINK SHUTOFF VALVE SOFTENED WATER SQUARE FEET STORM WATER PIPING TYPICAL UNDERGROUND UNIT HEATER URINAL VENT VENT THROUGH ROOF WALL CLEAN -OUT WATER CLOSET WITH CODED NOTES Q 1 ALL GREASE WASTE PIPING ABOVE AND BELOW SLAB IS TO HAVE HEAT TRACE AND INSULATION. 2 REMOVE EXISTING 3" ROOF DRAIN AND 3" OVER FLOW ROOF DRAIN AND REPLACE WITH 3" GENERAL NOTES 1. NO PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT MAY BE SUPPORTED FROM THE SUSPENDED CEILING SYSTEM, BUT MUST BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. 2. HAZARD CLASSIFICATION OF THIS SPACE IS TO BE ORDINARY HAZARD, GROUP 2. 0.2 GPM OVER 1500 SQUARE FEET. 130 SQUARE FEET MAXIMUM COVERAGE PER SPRINKLER HEAD, AS DETERMINED BY BORDERS' INSURANCE COMPANY. 3. PENDANT SPRINKLERS IN LAY -IN CEILINGS TO BE EQUAL TO VIKING MODEL M, SEMI RECESSED WITH MODEL E -1 WHITE FINISHED ADJUSTABLE ESCUTCHEON. UPRIGHT SPRINKLERS TO BE INSTALLED IN AREAS NOT HAVING CEILINGS. UPRIGHT SPRINKLERS TO BE VIKING MODEL M UPRIGHT. SPRINKLERS INSTALLED IN SOFFITS OR DRYWALL CEILINGS TO BE VIKING HORIZON MIRAGE CONCEALED SPRINKLERS WITH FLAT METAL COVER PLATES - WHITE FINISH. 4. THE SHELL CONTRACTOR IS PROVIDING THE WATER SERVICE TO THE BUILDING, FIRE RISER, SPRINKLER SYSTEM MAINS AND BRANCH LINES. TENANT IMPROVEMENT FIRE PROTECTION C`r "aTRAtTOR IS TO PROVIDE SWING ARMS, DROPS, AND SPRINKLER HEADS. 5. SPRINKLER HEADS MUST BE LOCATED A MIN. OF 18" AWAY FROM THE TOP OF ANY BOOK FIXTURES TO MEET CODE. 6. CONTRACTOR SHALL VERIFY IF SPRINKLER HEADS UNDER STOCK SHELVING ARE REQUIRED. 7. ALL CONCEALED PIPING SHALL BE TESTED AND PROVEN WEATHERPROOF PRIOR TO CONCEALMENT. 8. CONTRACTORS SHALL FOLLOW ALL CURRENT CODES AND BE LICENSED WITH CITY OR STATE AS REQUIRED. 9. ALL FLOOR DRAINS /CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR. 10. ALL FLOOR SINKS ARE TO BE INSTALLED EITHER FLUSH WITH FINISHED FLOOR, OR RAISED PER LOCAL CODE REQUIREMENTS. 11. ALL SPRINKLER HEADS LOCATED IN GYPBOARD CEILINGS SHALL BE CENTERED IN BETWEEN LIGHT FIXTURES UNLESS LAYOUT CONFLICTS WITH CODE REQUIREMENTS. 12. SEE SPECIFICATIONS FOR FIRE PROTECTION DESIGN AND INSTALLATION REQUIREMENTS. 13. CONTRACTOR SHALL CONTACT CIRQUA FOR WATER FILTRATION UNIT START -UP. SEPARATE PERMIT REQUIRED FOR: d Mechanic al 1VElectrical lumbing 'i Gas Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE Pit- PROVED FED • 2UU< City Of Tu k'�+�II Ua ���� REVISIONS No than S r �,cl to the so pe haul r .^4, } u NOTE: Revisions require a neod plan submittal and may include additional plan review fees. I Permit No. FILE COPY D Piar review approval Is subject to errors and orris l ions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. R ipt at approved Field ' opy d s is actnoWl ed By Date: City of Tukwila BUILDING DIVISION IJtV 01?' "7 h..ftil; I PROJECT NO. 2007.021 INTERIOR FINISH BORDERS INC. EXPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE "ARCHITECTURAL WORKS" AND "TECHNICAL DOCUMENTS" AND ANY DERIVITIVES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF BORDERS INC., NOR ARE THEY TO 0E ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT. © COPYRIGHT PENDING ISSUED FOR: PERMIT SU811 - rAL 9/28/07 _ SHEET TITLE OVERALL SANITARY PLUMBING PLAN STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. P100 LOUIS G. CHIODINI Architecture / Interior Design / Graphics 1401 South Brentwood Blvd. / Suite 425 / St. Louis, Missouri 63144 314-725-5588 / Fax 314-725-4347 PLUMBING FIXTURE SCHEDULE w (ALL FIXTURES & INSTALLATION PROCEDURES ARE TO MEET THE LOCAL PLUMBING CODE) MARK FIXTURE WASTE VENT H.W. C.W. MANE. MODEL # MODEL NAME NOTES AND ACCESSORIES WC -1 FLOOR MOUNTED WATER CLOSET FLUSH VALVE 4 " 2° - 1 " KOHLER #K -4350 WELCOME VITREOUS CHINA, WATER SAVER (1.6 GPF), ELONGATED BOWL WITH 1%" TOP SPUD, FLOOR MOUNTED. KOHLER #K- 4670 -C "LUSTRA" WHITE, OPEN FRONT SEAT WITH STAINLESS STEEL HINGES, LESS COVER, SLOAN "REGAL" FLUSHOMETER MODEL #111 FLUSH VALVE, TECHNICAL CONCEPTS SANITIZER PROVIDED BY BORDERS. INSTALLED BY CONTRACTOR. TECHNICAL CONCEPTS BATTERY OPERATED SENSOR TO CONTROL FLUSH VALVE PROVIDED BY BORDERS, INSTALLED BY CONTRACTOR. SEE MANUFACTURERS INFORMATION FOR CONNECTION TO SLOAN FLUSH VALVE. FLOOR BOLTS AND BOLT CAPS. ANGLE SUPPLY WITH STOP. WC -2 FLOOR MOUNTED WATER CLOSET FLUSH VALVE (ADA) 4' 2° - 1" KOHLER #K -4302 HIGHCREST VITREOUS CHINA, WATER SAVER (1.6 GPF), ELONGATED BOWL WITH 1%" TOP SPUD, FLOOR MOUNTED. KOHLER #K- 4670 -C "LUSTRA" WHITE, OPEN FRONT SEAT WITH STAINLESS STEEL HINGES, LESS COVER, SLOAN 'REGAL" FLUSHOMETER MODEL #111 FLUSH VALVE, TECHNICAL CONCEPTS SANITIZER PROVIDED BY BORDERS. INSTALLED BY CONTRACTOR. TECHNICAL CONCEPTS BATTERY OPERATED SENSOR TO CONTROL FLUSH VALVE PROVIDED BY BORDERS, INSTALLED BY CONTRACTOR. SEE MANUFACTURERS INFORMATION FOR CONNECTION TO SLOAN FLUSH VALVE. FLOOR BOLTS AND BOLT CAPS. ANGLE SUPPLY WITH STOP. FIXTURES TO BE FURNISHED AND INSTALLED IN ACCORDANCE WITH ADA AND LOCAL BARRIER FREE REQUIREMENTS L-1 COUNTER LAVATORY 12 " , 12 .. / } /" KOHLER #K 2602 S RHYTHM CHROME - PLATED LAVATORY SUPPLY ASSEMBLIES WITH LOOSE KEY STOPS. CHROME- PLATED WHEELCHAIR TAIL - PIECE. CHROME PLATED GRID STRAINER. TECHNICAL CONCEPTS BATTERY OPERATED AUTOMATIC FAUCET PROVIDED BY BORDERS, INSTALLED BY CONTRACTOR. PROVIDE TRAP AND SUPPLY PROTECTIVE INSULATOR EQUAL TO "INSUL GUARD" VANDAL RESISTANT PVC. MOUNT AT ELEVATIONS INDICATED ON ARCHITECTURAL DRAWINGS. UR-1 WALL HUNG URINAL 2" 11/2° - 4 „ KOHLER #K- 4989 -T FRESHMAN TECHNICAL CONCEPTS SANITIZER PROVIDED BY BORDERS. INSTALLED BY CONTRACTOR. SEE MANUFACTURERS INFORMATION FOR CONNECTION TO SLOAN FLUSH VALVE. SLOAN ROYAL" FLUSHOMETER MODEL NO. 186 -1 FLUSH VALVE. TECHNICAL CONCEPTS BATTERY OPERATED SENSOR TO CONTROL FLUSH VALVE PROVIDED BY BORDERS, INSTALLED BY CONTRACTOR. SEE MANUFACTURERS INFORMATION FOR CONNECTION TO SLOAN FLUSH VALVE. FIXTURES TO BE FURNISHED AND INSTALLED IN ACCORDANCE WITH ADA AND LOCAL BARRIER FREE REQUIREMENTS. FD -1 FLOOR DRAIN SEE PLAN - - Y J.R. SMITH 2100 SERIES _ PROVIDE WITH MINIMUM 4° DEEP SEAL TRAP, SEDIMENT BUCKET, HINGED GRATE, AND OUTLET AS REQUIRED BY PIPING MATERIAL. FD -2 FUNNEL FLOOR DRAIN SEE PLAN - ' /z" J.R. SMITH 3500 SERIES - PROVIDE WITH MINIMUM 4' DEEP SEAL TRAP, ADJUSTABLE STRAINER HEAD WITH SECURED SQUARE HOLE GRATE AND FUNNEL ATTACHED. OUTLET AS REQUIRED BY PIPING MATERIAL. FCO FLOOR CLEANOUT - - - - J.R. SMITH 4000 SERIES - ADJUSTABLE CLEANOUT NICKEL BRONZE OR CHROME FINISH, IF FLOORS ARE TILED, OR TERRAllO. USE RECESSED TOP IF FLOORS ARE CARPETED. CLEANOUTS ARE TO BE FLUSH WITH FINISHED FLOOR. WCO WALL CLEANOUT - - - - J.R. SMITH 4400 SERIES - THREADED CLEANOUT PLUG WITH FERRULE AND ROUND ACCESS COVER NICKEL BRONZE OR CHROME FINISH. EWC -1 ELECTRIC WATER COOLER 1%' 1%" - %" ELKAY ERPA28RAC - THE VANDAL RESISTANT, TWO LEVEL WHEEL CHAIR ACCESS UNIT, TWO FOUNTAINS WITH ONE AT WHEELCHAIR HEIGHT AND ONE AT CONVENTIONAL HEIGHT. ADA COMPLIANT FRONT PUSH BAR, 8.0 GPH, 1/5 HP, 120 VOLT FOR EACH UNIT. MOUNT LOWER UNIT WITH RIM AT 34" AFF. COLOR TO BE SELECTED BY ARCHITECT FROM STANDARD COLOR CHART. S -1 LOUNGE SINK 1Y° 1'2° %" %" ELKAY #LRAD -2521 LUSTERTONE CHROME - PLATED LAVATORY SUPPLY ASSEMBLIES WITH LOOSE KEY STOPS. CHROME - PLATED TUBULAR "P" TRAP. KOHLER #K15171 8 1/2" SWING SPOUT, SINGLE LEVER FAUCET. ELKAY #LK -18 DRAIN WITH PERFORATED GRATE SS -1 FLOOR MOUNTED SERVICE SINK 3" 1%' -° V" FIAT MSB -2424 MOLDED STONE FLOOR MOUNTED SINK. PROVIDE WITH FIAT #830 -AA S.S. FAUCET WITH VACUUM BREAKER, HOSE END, STOPS, AND 30" HOSE W/ HOSE BRACKET ALONG WITH FIAT #1453.BB FLAT STRAINER. HB HOSE BIBS _ ye W ATTS BD QT FORGED BRASS BODY QUARTER TURN BALL VALVE, 1/2" WATER CONNECTION, 3/4" HOSE CONNECTION TO BE SUPPLIED WITH WATTS VACUUM BREAKER MODEL NUMBER 8A, AND WALL ESCUTCHEON. WH -2 WATER HEATER - - a C•)■ IN SINK ERATOR W -152 2 -1/2 GALLON WATER HEATER SHALL BE BRONZE LONG -LIFE STORAGE TANK WITH SCREW -IN COPPER HEATING ELEMENT. 2 -% GALLON STORAGE, 1500 WATTS, 120V /1PH, 150 PSI OPERATING, 8.6 GPH RECOVERY @ 80° RISE, %" PRESSURE RELIEF CONNECTION. INSULATED WITH EXPANDED POLYSTRYENE, ONE YEAR FULL WARRANTY, DRAIN PROVIDED FOR MAINTENANCE. STANDARD P.D.I. WH 201 WATER HAMMER ARRESTER SCHEDULE P.D.I. UNITS O a a ® O O a FIXTURE UNITS 1 - 3 1 - 11 12 - 32 33 - 60 61 - 113 114 - 154 155 - 330 2" SAN PIPING B /F. SEE SHEET P100 FOR CONTINUATION OF PIPING. NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. 1 NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. ENLARGED BREAK ROOM SANITARY PLUMBING PLANS SCALE: 1w. TA:1" 2" CW PIPING OVERHEAD. SEE SHEET P100 FOR CONTINUATION OF PIPING. 2" CW PIPING OVERHEAD. SEE SHEET P100 FOR CONTINUATION OF PIPING. 1 H I I WH -2 MOUNT TO ` BACK OF CABINET — BELOW S-1 GW 2' HUB DRAIN 3/4" 0/H ENLARGED BREAK ROOM DOMESTIC WATER PLUMBING PLANS SCALE: 1/4"7 3/4' CW DN IN WALL 1/2" TO 5 -1 & WIH -2 1 1/2' V 0/H 1 1 -1/2" VENT PIPING 0 /H. SEE CONTINUATION OF PIPING ON THIS SHEET. • J 1 3/4" HW P PI ING QyERHEAD. SEE SHEET ,P120 FOR 5 CONTINUATION•OF PIPING. L \ f � (! 2' CW PIPING OVERHEAD. SEE SHEET P100 FOR 5 CONTINUATION OF PIPING. I/ it i NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. HW T EWC -1 1/2" CW l 71TO EWC 1 SCALE; 114" =1'-0" L -1 WC-1f i WC 1 / LOCATE VALVES ABOVE ACCESSIBLE CEILING L - 1 •L1 / l L ) UR -1 'CW WC 2 1! I ) WC -2 ! f I ire r - Z ENLARGED TOILET ROOMS DOMESTIC WATER PLUMBING PLANS t 1 112 WATTS OO8PCQT SERIES SPILL RESISTANT, ANTI - SIPHON VACUUM BREAKER 1/2" CW DN WITHIN WALL TO HB 1/2" CW & HW DN WITHIN WALL TO SS -1 eTh v 4' SAN PIPING B /F. SEE SHEET P100 FOR CONTINUATION OF PIPING. L_- • I 2" VENT PIPING DOH. H SEE SHEET P120 FOR i CONTINUATION OFIPIPIN • n / t 1 ' NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. SCALE: 1/4"=t-0" WC -1' FD -1 c 1 FCO 1 -1/2" 0/H 1 -1/2" VENT PIPING OIH. SEE CONTINUATION OF. PIPING ON THIS SHEET. 3" 0/H L -1 ENLARGED TOILET ROOMS SANITARY PLUMBING PLANS EXISTING 3" VENT PIPING -5 0 /H. COORDINATE EXACT LOCATION WITH SITE. REVIEWED FUR NODE CO APPROVED Cif? Of Tu'.Wyt T� x 1 ?&O7290 PROJECT NO. 2007.021 INTERIOR FINISH BORDERS INC. EICFRES5LY RESERVES HS CONON LAW P240 STATUTORY LAW COPYRIGHTS AND OTHER FRCFERIY i7.i1s FOR THESE "ARCIMECTURAL WORKS" AND "MGMAI. DOCUMENTS APO ANY DER IT1UES THEREOF THESE DRAWINGS AND DOCIAENIS ARE NOT 10 BE REPRODUCED. CHANGED CR COPED N ANY FORM CR MANNER WHATSOEVER FCR ANY WE WWT14OUT FIRST WARING THE DFTESS MITTEN CONSENT CF BORDERS INC.. NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WRHOUT FAT CBTARINO SAD WRITTEN PER11SSCN AND CONSENT. © scrfinair FeselG ISSUED FOR: PERM SUBM TAL 9/28/07 SHEET TITLE TOILET ROOM & BREAK ROOM PLUMBING PLANS STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. P110 PLUMBING FIXTURE SCHEDULE (ALL FIXTURES & INSTALLATION PROCEDURES ARE TO MEET THE LOCAL PLUMBING CODE) MARK FIXTURE WASTE VENT H.W. C.W. MANF. MODEL # MODEL NAME NOTES AND ACCESSORIES SS -1 FLOOR MOUNTED SERVICE SINK 3" 1%° Y2 I Y° FIAT MSB -2424 - MOLDED STONE FLOOR MOUNTED SINK. PROVIDE WITH FIAT #830 -AA S.S. FAUCET WITH VACUUM BREAKER, HOSE END, STOPS, AND 30" HOSE W/ HOSE BRACKET ALONG WITH FIAT #1453.BB FLAT STRAINER. FD -1 FLOOR DRAIN SEE PLAN - - 12 J.R. SMITH 2100 SERIES - PROVIDE k' /ITH MINIMUM 4° DEEP SEAL TRAP, SEDIMENT BUCKET, HINGED GRATE, AND OUTLET AS REQUIRED BY PIPING MATERIAL. FS -1 FLOOR SINK ' SEE PLAN — — SEE PLAN - - J.R. SMITH 3100 SERIES _ _ ` — - FLOOR SINK IS TO BE 12 °X12 ". PROVIDE DEEP SEAL TRAP WITH FLOOR SINK. SEDIMENT BUCKET, NICKEL BRONZE TOP, 1/2 GRATE, AND OUTLET AS REQUIRED BY PIPING MATERIAL. FD -2 FUNNEL FLOOR DRAIN SEE PLAN _ _ _ J.R. SMITH 3500 SERIES - PROVIDE WITH MINIMUM 4 DEEP SEAL TRAP, ADJUSTABLE STRAINER HEAD WITH SECURED SQUARE HOLE GRATE AND FUNNEL ATTACHED. OUTLET AS REQUIRED BY PIPING MATERIAL. FCO FLOOR CLEANOUT 3/8 - - - J.R. SMITH 4000 SERIES _ ADJUSTABLE CLEANOUT NICKEL BRONZE OR CHROME FINISH, IF FLOORS ARE TILED, OR TERRAllG. USE RECESSED TOP IF FLOORS ARE CARPETED. CLEANOUTS ARE TO BE FLUSH WITH FINISHES FLOOR. HB HOSE BIBB 3 _ _ j° WATTS BD QT 3/4' FORGED BRASS BODY QUARTER TURN BALL VALVE, 1/2° WATER CONNECTION, 3/4° HOSE CONNECTION TO BE SUPPLIED WITH WATTS VACUUM BREAKER MODEL NUMBER BA, AND WALL ESCUTCHEON. WCO WALL CLEANOUT 3 COMPARTMENT SINK - 1/2" (3) 1-1/2' J.R. SMITH 4400 SERIES _ THREADED . CLEANOUT PLUG WITH FERRULE AND ROUND ACCESS COVER NICKEL BRONZE OR CHROME FINISH WH -1 WATER HEATER - - 1Y° We A.Q. SMITH DVE -80 -45 - GLASS -LINED WATER HEATER 80 GALLON STORAGE, 45 KW INPUT @ 480 VOLT /3 PHASE, 184 GPH RECOVERY @ 100 DEGREE F TEMPERATURE RISE. HEATER WARRANTY SHALL BE 3 YEARS. FURNISH HEATER WITH APPROPRIATE WATTS REGULATOR TEMPERATURE AND PRESSURE (T &P) RELIEF VALVE ALONG WITH A VACUUM BREAKER VALVE. FACTORY PROVIDED WATER HEATER DRAIN PAN. SAFEWASTE FULLSIZE T &P RELIEF PIPE AND 3/4° DRAIN PAN DRAIN TO NEAREST MOP SINK. ALL SAFEWASTE PIPING TO BE CONCEALED. EXPANSION TANK - AMTROL THERMAL EXPANSION ABSORBER MODEL ST -12, 6.4 MAXIMUM ACCEPTED GALLONS. EQUIPMENT SCHEDULE TAG QTY. DESCRIPTION COLD HOT WASTE REMARKS (E100) 1 ESPRESSO MACHINE - SBC 3/8° - 3/4° 1,2,3,4 1 COFFEE BREWER - SBC 1/4 - - 1,6 (E166) (E110) 1 ICE -BIN - DROP IN - - (2) 1 1/2° 3 ® 2 DIPPERWELL ASSEMBLY 1/2 - 1 1/2° 3 E144 1 WORK SINK 1/2° 1/2° 1 1/2" 3 (E143) 1 HAND SINK - 2 HOLE 1/2° 1/2° 1 1/2° (E125) 1 ICE MACHINE - 500 LB 3/8 3/4 & 1 -3/8' 1,3 (E127) 1 DISHWASHER - 3/4° 3/4° 3 (E136) 1 WATER FILTER (C SYSTEM) 1/2° - 3/4' 3,5 (E139) 1 3 COMPARTMENT SINK 1/2' 1/2" (3) 1-1/2' 3 (E141) 1 WALL MOUNTED HANDSINK WITH FAUCET 1/2" 1/2" 1 1/2° E142 y E150 =— 1 J � FAUCET GLASS FILLER 1 — 1 2" — — a 1 -1 2° 1 3 1 SODA DISPENSER 3 - 1,2,3 REMARKS: 5. REQUIRES 40 TO 90 PSI WATER SUPPLY. ADD PRESSURE REDUCING VALVE OR BOOSTER PUMP AS 1. CONNECT TO FILTER SYSTEM REQUIRED. 2. REQUIRES MIN. 30 PSI WATER SUPPLY 6. 1/2" SUPPLY W/ 36" BRAIDED STAINLESS STEEL 3. INDIRECT WASTE HOSE. 4 . REQUIRES MAX. 30 PSI WATER SUPPLY. ADD REGULATOR TO ADJUST PSI ACCORDINGLY. - GENERAL NOTES: 1. ALL THE EQUIPMENT PROVIDED BY THE F.S.E.C. SHALL BE DELIVERED TO THE JOB AND SET -IN- PLACE, READY FOR FINAL CONNECTIONS. PLUMBING CONTRACTOR SHALL PROVIDE FINAL CONNECTIONS, AND ALL MATERIALS REQUIRED FOR CONNECTIONS, IN ACCORDANCE TO LOCAL CODES. 2.IT IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO VERIFY EXISTING UTILITY REQUIREMENTS AND USE WITH NEW LAYOUT AND EQUIPMENT REQUIREMENTS. 3. ALL DIMENSIONS GIVEN ARE FROM FINISHED SURFACES (WALLS, FLOORS, ETC.) TO FINISHED SURFACE AND /OR CENTER OF UTILITY SERVICE. 4. UNDER NO CIRCUMSTANCE ARE THE COUNTER TOPS OR EQUIPMENT TO BE WALKED ON AT ANY TIME BY ANY TRADES PERSON. . 5. PLUMBING CONTRACTOR TO PROVIDE WATTS #SD -3 BACK FLOW PREVENTOR FOR CARBONATOR EQUIPMENT. REFER TO MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. REFER TO PLANS FOR CONNECTION SIZE. 6. SEE EQUIPMENT SCHEDULE ON DWG FSE -1 FOR ADDITIONAL INFORMATION ON KITCHEN EQUIPMENT. 7. PROVIDE QUARTER TURN STOPS FOR ALL SUPPLY CONNECTIONS FOR KITCHEN EQUIPMENT. 8. ALL RO / FW PIPING TO BE COPPER SIMILAR TO DOMESTIC WATER PIPING. SEE SPECIFICATIONS. STANDARD P.D.I. WH 201 WATER HAMMER ARRESTER SCHEDULE P.Q.I. UNITS AA QA ® ® ® ® FO FIXTURE UNITS 1 - 3 1 - 11 12 - 32 33 - 60 61 - 113 114 - 154 155 - 330 SCALE: NONE WATER +22 "H MOUNTED ON SIDE PANEL OF CORNER CABINET C7 N N SCALE: 114 " =1' -0" Drain +16 °Water C K ALvE y EXP 1 -1 P iAL)E & CDD R ANSTDN TA 4° NW EP Vgly K N / VAL V E ET +16" m I -- (E166) \ i-y Drain °• *i6 °H for ork Sink T +16 °Wafer 1 1h° Drain +16 °H for Nand Sink +16 "Water (E143) [p 5' -11" NOTE: RUN WATER LINES ALONG INSIDE OF CABINETS & THROUGH CASEWORK TO (E123) POINT OF USE FILTERED CW FOR END ESPRESSO MACHINE +16 "H UNFILTERED CW FOR E117 DIPPERWELL +22 "H ENLARGED CAFE DIMENSIONAL PLAN '1 qNE DL GE NOTES: W` uNIDN SEE EQUIPMENT SCHEDULE FOR CONNECTION SIZES. NI CAL) CIRQUA C SYSTEM & WATER HEATER PIPING DETAIL 4° SAN B/F & 4' OW B /F. SEE SHEET P100 FOR CONTINUATION OF PIPING. NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. SS -1 4 - - - - V - — — S FOR CONTINUATION OF PIPING. 2' VENT 0 /H. SEE SHEET P100 ENLARGED CAFE SANITARY PLAN SCALE: 1/4 " =1' -0" CODED NOTES ® 1. ALL GREASE WASTE PIPING ABOVE AND BELOW SLAB IS TO HAVE HEAT TRACE AND INSULATION. 1/2° HW AND CW DOWN TO LEONARD MODEL 108 -BP THERMOSTATIC MIXING VALVES ON E141 & E144. SEE SHEET P200 FOR DETAILS. WATTS ;'rSD -3 BACKFLOW PREVENTER WITH VENT. INSTALL PER MANUFACTURER'S RECCOMENDATIONS. ROUTE WASTE LINE TO FD -2. it E100 E117 E150 g.. E136 E143 E166 1/2° CW & RO DN WITH IN WALL RUN LINES IN CASE WORK TO E100, E117 & E142 SEE PIPING DETAIL ON THIS SHEET FOR CONTINUATION OF PIPING IN THIS AREA. 1/2° CW DN WITH IN WALL TO HB 1/2" CW & HW DN WITH IN WALL TO SS -1 1/2° WATTS 008PCQT SERIES SPILL RESISTANT, ANTI- SIPHON VACUUM BREAKER NOTE: SEE RISER DIAGRAM ON DRAWING P130 FOR SIZES AND ADDITIONAL INFORMATION. ENLARGED CAFE DOMESTIC WATER PLAN SCALE: 114 " =1' -0" WH -1 SS- 1 -1/2' 0/H E125 1 -1/2 CW 0/H FROM EXISTING 2° CW 0 /H. SEE SHEET P100 FOR CONTINUATION OF PIPING. _— _— _jr ... _ ...J 3/4° WATTS 008PCQT SERIES_. SPILL RESISTANT, \ - -- ANTI- SIPHON VACUUM BREAKER / 3/4 HW 0 /H. SEE SHEET P100 FOR /./ CONTINUATION OF PIPING. T F&O1' z ID r Mp CORRECTION LTR # ___ ECG IV b DEC 2.0 2007 PERMIT CENTER PROJECT NO. 2007.021 INTERIOR FINISH BORDERS INC. EXPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE 'ARCHITECTURAL. WORKS' AND 'TECHNICAL DOCUMENTS' AND ANY DERIVITIVES THEREOF. THESE DRAVANGS AND DOCUMENTS ARE NOT TO BE REPRODUCED. CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF BORDERS INC.. NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WI ITIEN PERMISSION AND CONSENT. © COPYRIGHT PENDING SHEET TITLE ENLARGED CAFE PLUMBING PLANS STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. P120 3/4' OVER HEAD DOMESTIC WATER PIPING. SEE SHEET P100 FOR CONTINUATION. 1/ I A 112" C AFE 1/2 R0 SE RI CE 1 1.1/4, U 1 3 /4. 1H- N. 314, Cdd ` -• 31 4 , 1 REFER TO SHEET P120 FOR CIROUA C SYSTEM & WATER HEATER PIPING DETAIL 1/ 3/4, H,y 1 1h 1/, - 2 2 RU - I �� -:_ I '. 1.1 o/N 112' ]- \ - � � � •..• Wq 1 T 4A� "MTgC4�,ERI 9RIp 40N Sp ILL 1^ / A AN NIPo Rr4 7YpI�NG ICS CAFE DOMESTIC WATER, SANITARY & VENT PIPING RISER DIAGRAMS 4' GREASE WASTE PIPING BELOW FLOOR FROM CAFE. SEE SHEET P100 FOR CONTINUATION. 2' VENT PIPING OVER HEAD FROM CAFE. SEE SHEET P110 FOR CONTINUATION. 4' SANITARY PIPING BELOW FLOOR FROM CAFE. SEE SHEET P100 FOR CONTINUATION. .- 014 ;-) 3/4' OVER HEAD DOMESTIC WATER PIPING. SEE SHEET P110 FOR CONTINUATION. 2' VENT PIPING OVER HEAD FROM CAFE. SEE SHEET P120 FOR CONTINUATION. 1 -1/2' OVER HEAD DOMESTIC WATER PIPING. SEE SHEET P100 FOR CONTINUATION. 0 /H )/ 2 34 0/H N. . �/ „f R. u /HST 2 / 0 /H / .r I � - 1 - T. 1/2h 3/4' OVER HEAD DOMESTIC HOT WATER PIPING. SEE SHEET P120 FOR CONTINUATION. / O /H / 3 p // / / 2' SANITARY PIPING BELOW FLOOR FROM BREAK ROOM. SEE SHEET P100 FOR CONTINUATION. 2' OVER HEAD DOMESTIC WATER PIPING. SEE SHEET P100 FOR CONTINUATION. NVy w ■ - 0 / H olH W " OIU -` 0 00 °111 4 SANITARY PIPING BELOW FLOOR FROM TOILET ROOMS. SEE SHEET P100 FOR CONTINUATION. / / 3 ' /// \ / Cfi � / `� TOILET ROOM DOMESTIC WATER, SANITARY & VENT PIPING RISER DIAGRAMS SCALE NONE EMPLOYEE BREAK ROOM DOMESTIC WATER SANITARY & VENT PIPING RISER DIAGRAMS SCALE: NONE 1 -1 /2' VENT PIPING OVER HEAD FROM BREAK ROOM. SEE CONTINUATION OF PIPING ON THIS SHEET. / 4' 010 •�� 1 -1/2' VENT PIPING OVER HEAD FROM BREAK ROOM. SEE CONTINUATION OF PIPING ON THIS SHEET. 3/4° OVER HEAD DOMESTIC WATER PIPING TO BREAK ROOM. SEE SHEET P100 FOR CONTINUATION. gpLL VPI' 11 3' VENT PIPING 0/H TO EXIST 3' PIPING 0 /H. SEE SHEET P100 FOR CONTINUATION. 11 .1/2% 1 '' 1/2, CO32'10 4 © - i i r!� C ©D � � OPRCAIZ - 1 •'� RECEIVED DEC 2 0 2007 PERMIT CENTEF PROJECT NO. 2007.021 INTERIOR FINISH BORDERS IN EXPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE "ARCHITECTURAL WORKS AND 'TECHNICAL DOCUMENTS' AND ANY DERIVITIVES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED. CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF BORDERS INC.. NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT. © COPYRIGHT PENDING 0 cC W Z Z 0 _ 0 1- ISSUED FOR: PERMIT SUBMITTAL / \ REVISION 1 9/28/07 12/17/07 SHEET TITLE PLUMBING PIPING DIAGRAMS STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. P130 FINISHED FLOOR FLOOR SLAB DIAMETER REFER TO PLAN - SCALE: NONE PLACE HEAD IN CENTER OF TILE ACOUSTIC TILE TYPE 1 CENTER THE HEAD IN THE 24° x 24° SECTION OF THE TILE ACOUSTIC TILE TYPE 2 & 3 SPRINKLER HEAD LOCATIONS DETAIL SCALE: NONE FLOOR SINK DETAIL PRECISION PLUMBING PRODUCTS MODEL 50R TRAP PRIMER VALVE 1" SOFT COPPER PRIMER LINES FLOOR 4° DEEP SEAL TRAP SCALE: NONE TO OTHER FLOOR DRAINS 0 PLACE HEAD IN CENTER OF TILE ACOUSTIC TILE TYPE 2 & 3 NOTE: PROVIDE WITH WHITE ESCHUTCHEONS UNLESS OTHERWISE NOTED DISTRIBUTION UNIT AS REQUIRED FOR SERVING MULTIPLE TRAPS -CONN TO TRAP PRIMER VALVE PRIMER PIPING CONCEALED IN WALL 4" DEEP SEAL TRAP TRAP PRIMER DETAIL STEEL GRATE TOP FLUSH WITH FINISHED FLOOR THIS SIDE REPRESENTS A DIFFUSER OR LIGHT NEAREST COLD WATER SOURCE MIN, 1 MAX ACCESSIBLE LAY IN CEILING (A.C.T. /GRID) WHERE APPLICABLE FLOOR DRAIN CEILING SPACE n TO EXISTING EXTERIOR GREASE INTERCEPTOR DISHMACHINE CONNECT TO WASTE LINE WITH AIR GAP SEE DETAIL THIS SHEET. SCALE: NONE HANGER ROD LOCKING NUT SUPPORT NUT HEAVY DUTY CLEVIS " HANGER. MATERIAL TO MATCH PIPE. PIPE GENERAL NOTES: SCALE: NONE CLEVIS (HANGER SINGLE !HORIZONTAL RUNS NO VAPOR BARRIER INSULATION SCALE: NONE FLOOR SINK 3 COMPARTMENT SINK AND DISHWASHER DETAIL HW ROUGH -IN WITH 3 /4 ° BALL VALVE, LINE STRAINER, WATER PRESSURE REGULATOR AND TRANSITION TO 3 /° MALE GARDEN HOSE FITTING CONN TO DISHMACHINES 3 /° FEMALE GARDEN HOSE FITTING. ESCUTCHEON WATER HAMMER ARRESTER SEE SHEET P120 FOR CONTINUATION. 6' LONG DRAIN HOSE SUPPLIED W/ MACHINE TERMINATES W 3 /q° MPT FITTING TERMINATE %" HARD COPPER PIPE W/ 9(4° FPT FITTING AND CONNECT TO MFGR. DRAIN HOSE. 9'4" HARD COPPER PIPE. CONNECT TO AIR GAP FITTING JR SMITH #3950T AIR GAP FITTING W/ 1 - THREADED OUTLET CLAMP TO WALL ESCUTCHEON 1. PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES. DRAIN AND FILL LINE CONFIGURATIONS VARY, SOME METHODS ARE SHOWN ON THIS DRAWING. DISHWASHER CONNECTION DETAIL PIPE SUPPORT DETAIL CLEVIS HANGER SINGLE HORIZONTAL RUNS WITH VAPOR BARRIER INSULATION SCALE: NTS LEONARD MODEL 108 -BP THERMOSTATIC MIXING VALVE WITH BYPASS THERMOSTATIC MIXING VALVE DETAIL THREE COMPARTMENT SINK HANGER ROD LOCKING NUT SUPPORT NUT HEAVY DUTY CLEVIS HANGER. MATERIAL TO MATCH PIPE. VAPOR BARRIER INSULATION 16 GA. ZINC COATED SHEET STEEL SADDLE 8 LONG MINIMUM FINISHED FLOOR 4" GW B/F TO EXISTING EXTERIOR GREASE INTERCEPTOR. CODE COMPLIANCE FEB P(20 Z 0 1C W Z Z U 15 C 1' 1EXPJRES 74,1 s /v9 t lailsfa RECEIVED DEC 2 '0 2007 PERMIT CENTER PROJECT NO. 2007.021 INTERIOR FINISH BORDERS IN EXPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE "ARCHITECTURAL WORKS' AND 'TECHNICAL DOCUMENTS' AND ANY DERMMTIVES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF BORDERS INC.. NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT. GO COPYRIGHT PENDING ISSUED FOR: PERMIT SUBMITTAL A\ REVISION 1 9/28/07 12/17/07 SHEET TITLE PLUMBING DETAILS AND SCHEDULES STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. P200