Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG07-297 - WESTFIELD SOUTHCENTER MALL - SUNGLASS HUT
SUNGLASS HUT 2846 SOUTHCENTER MALL PGO7-297 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Value of Plumbing /Gas Piping: Fees Collected: doc: UPC-10 /06 City.of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2846 SOUTHCENTER MALL TUKW SUNGLASS HUT 2846 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: MARTHA MARTIN Address: 1327 POST AV, SUITE H , TORRANCE CA Contractor: Name: PUGET SOUND BUILDERS NW INC Address: 18852 72ND AVE S , KENT, WA Contractor License No: PUGETSB000OQ DESCRIPTION OF WORK: INSTALL PLUMBING FIXTURES AND ASSOCIATED SANITARY AND WATER PIPING. $8,000.00 $145.00 plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 1 Shower, single head trap 0 Lavatory 1 Wash fountain Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 1 PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND OUANTITY 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: PGO7 -297 04/14/2008 10/11/2008 Phone: Phone: 310- 328 -6300 X 104 Phone: 425 251 -1661 Expiration Date: 09/20/2009 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 1 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 PG07 -297 Printed: 04 -14 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of this permit does construction or the perf doc: UPC -10/06 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: Issue Date: Permit Expires On: PGO7 -297 04/14/2008 10/11/2008 Date: 0 L ed this permit and know the same to be true and correct. All provisions of law and ordinances ther specified herein or not. o give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this plumbing /gas piping permit. 4114 las Signature: S !• Date: Print Name: R - r - ago This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -297 Printed: 04 -14 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: SUNGLASS HUT 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2846 SOUTHCENTER MALL TUKW PERMIT CONDITIONS PG07 -297 ISSUED 11/05/2007 04/14/2008 * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 8: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 9: All pipes penetrating floor /ceiling assemblies and fire resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 10: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -297 Printed: 04 -14 -2008 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not pr to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance •f w Date: 4 l R l PG07 -297 Printed: 04 -14 -2008 SITE LOCATION Site Address:_aaltaaUEA Tenant Name: � U1J toe-75 f-f or New Tenant: Property Owners Name: 1IJP:SiTnE D / A : Pizoom. Mailing Address: lI O 1 L(tL51-1i12.0 l ,VII • FL, Lo$M4 .fi5 City State CONTACT PERSON — who do we contact when your permit is ready to be issued Day Telephone: ' -n • 10 1 ' 1 1 City State Zip • E -Mail Address:_ aV M PreC spar1iL- -C r Fax Number: - 3 j it" ,ita 4 ►•> a Name: Mailing Address: 1 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98186 http://www.ci.tukwila.wa.us t5, Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record (AaiLP44 i iu - Am-T zr Company Name: Mailing Address: -Ill (61-1)02— Contact Person: &IA R055tW E -Mail Address: ] f(Q off ict 0. . tf_ t Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Compan ( er T2l ? '' 4d C Kit S , 1 , ' Mailing Address: l 0 o f2.1). c i 100 C1 Nl✓[i4l4J 11 014 46 City State zi Day Telephone: 513 - / — 55 Fax Number: 513 -7q'a - "79 Contact Person: ta...pl'fs`i J, \M D E -Mail Address: SV j @ . in4fr * chdn3 n • net Q.\Apptications\Forms- Applications On LnM3 2006 Permit Appbcation.doc Rcvised: 9 - 2006 bb Project No. Building Permit No. 1)0 "1- 4 -1 1 2 Mechanical Permit No. 1•40 - Z 1 ( Plumbing/Gas Permit No. 1 Public Works Permit No. Poi (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** K i n g Co Assessor's T a x No.: 2 Z 304-9'004 Suite Number: Z /SS _ Floor: 2 - State Yes Zip Zip City Day Telephone: Fax Number: Expiration Date: P-7. QuNbi rt4 , • State —7 to bl Z Day Telephone: RI 1- L6-5 �q(0 Page 1 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 1 Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory 1 Water Closet I Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: 11SD Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ £ I 000 • (7 C 7 Valuation of Gas Piping work (contractor's bid price): $ — — Scope of Work (please provide detailed information): ,fWsT4Lf 'Mum a �i Y4vK l a of ctSS ock ecl Set . - U '>g Ctie toA ' 4cr Qi'i Cep a Lek et I/ ( �n ne(JINNI.) Pro Eius hnr ( :A.t.s Building Use (per Int'l Building Code): C l,Ored Mud/ 13m.ddi r c Occupancy (per Int'l Building Code): M — MF'ir(04V1�-► l�. Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:Upplications\Fonns- Applications On Line\3 -2006 - Permit Application.doe Revised: 9 -2006 bh Sewer: Page 5 of 6 Date Application Accepted: ...., Q: Appliations\Fomns- Applications On LineN3 -2006 - Remit Appliation.doc Revised: 9 -2006 bb PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN ' OR AUTHORIZ s AGENT: Signature: Date: lb 'ova' -0 Print Name: 614' 14� :l- t'ICI0 F Mailing Address: 6 1 4 V D CM2 i 2 p_l Dow 100 G# L UJM l , (741- +524-2- City State Zip Day Telephone: 5/ Date Application Expires: Staff Initials: Page6of6 Doc: RF.C,SFTS -fl RECEIPT NO: R08 -01162 Initials: WER User ID: 1655 Payee: PUGET SOUND BUILDERS NW INC. SET ID: 0414 SET NAME: SUNGLASS HUT SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http../1www.d.tukwila.wa.us D07 -412 1,888.84 D07 -420 1,886.34 M07 -240 230.88 M07 -244 230.88 PG07 -297 115.50 PG07 -303 118.00 TOTAL: 4,470.44 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 22665 4,470.44 TOTAL: 4,470.44 ACCOUNT ITEM LIST: Description BUILDING - NONRES MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 3,766.18 000/322.100 461.76 000/322.100 233.50 000/386.904 9.00 TOTAL: 4,470.44 Payment Date: 04/14/2008 Total Payment: 4,470.44 Receipt No.: R07 -02421 Initials: WER User ID: 1655 Payee: EXPRESS PERMITS ACCOUNT ITEM LIST: Description PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: PG07 -297 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/05/2007 Applicant: SUNGLASS HUT Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 10144 2.50 Account Code Current Pmts 000/322.100 2.50 Total: $2.50 Payment Amount: $2.50 Payment Date: 11/05/2007 12:18 PM Balance: $115.50 doc: Receiot -06 Printed: 11 -05 -2007 Receipt No.: R07 -02420 Payee: EXPRESS PERMITS ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: PG07 -297 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/05/2007 Applicant: SUNGLASS HUT Issue Date: Initials: WER Payment Date: 11/05/2007 12:15 PM User ID: 1655 Balance: $115.50 TRANSACTION LIST: Type Method Description Amount Payment Check 10144 27.00 Account Code Current Pmts 000/345.830 27.00 Total: $27.00 Payment Amount: $27.00 'e doc: Receiot -06 Printed: 11-05 -2007 Project; LitsCC IAsS Type of Inspection: - - 1 04 1 --PlU 6 A�dr e nq nn AA k V Date Called: Special Instructions: Date Wanted: -- 7` 1 -7- a:tfr m. Requester: Phone No: 1 1- 1 4—1 5Y0 7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: t°' 'Date: 7/ 7 / 6 LI $60 ' EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: ll /,� -k ?ef or.�t i 4 ?cc.lko . X44 7 cir# n , A oilewu5, Address' // y� ,°ems 1/ A_/A pr4h/pa4 , 5 Peso %ti Special Instructions: Date Wanted: a.m. Requester: Phone No Pro ' 2/�v6�$S ///f Type of Inspection: / /Ai q /4 h Address' // y� Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA, 98188 (206)431 -3670 n Approved per applicable codes. IA Corrections required prior to approval. Inspector: 17 $60.1 ' .1 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Date: i-% 72T7 0 Project: T fpe of In i�on / : Address &'2 n119 r Date Called: Special Instructions: Date W ed: q a, Requester: Phone No: J 7 -ZY7 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit El Approved per applicable codes. Corrections required prior to approval. COMMENTS: e i G>'J4 ,(,.// Z, 1/vf c.Jc o1 ale k /PI" . n! G (Inspector: .� rd�" :. `y" ` az.tL r. -,�.. f<...e�+... ra1y.,..'.vF -ri� I Date: ' /y /eig El $60.0¢ f�E NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: IDate: Pr /m /,ass f/ Typepf Inspecti n: AM)/c4 5 Date Called: Ac .'7 • �f4 41/97( Special lnstructions: Da( anted: a.m Requester: Phon N�o: 1 s f-2/ / El Approved per applicable codes. Inspector: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Corrections required prior to approval. COMMENTS: Gl O To Top of 1 w V c K . T., or Gi. I I El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 1Date: 04 -04 -2008 MARTHA MARTIN 1327 POST AV, SUITE H TORRANCE CA 9050 Dear Permit Applicant: City of Tukwila RE: Permit Application No. PG07 -297 2846 SOUTHCENTER MALL TUKW Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current permit application files, it appears that your permit application applied for on 11/05/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 05/03/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 05/03/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: pti er Marshall t Technician Permit File No. PG07 -297 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DE ARTMEN u `I Build g Dlvl ion X Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 - 297 DATE: 11 -05 -07 PROJECT NAME: SUNGLASS HUT SITE ADDRESS: XXX SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued APPROVALS OR CORRECTIONS: Public Works )I?ERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -6 -07 Fire Prevention Structural Incomplete Structural Review Required Planning Division Permit Coordinator Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 12 -4 -07 )11 n Approved ❑ Approved with Conditions IA Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PUGETSB0000Q Licensee Name PUGET SOUND BUILDERS NW INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601341357 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 21019 66TH AVE S Address 2 City KENT County KING State WA Zip 98032 Phone 2535205833 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/18/2000 Expiration Date 9/20/2009 Suspend Date Separation Date Parent Company Previous License PUGETSB099PD Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 CBIC 659303 09/20/2001 Until Cancelled $12,000.00 08/14/2001 #1 CBIC 659303 09/20/1991 09/20/2001 $6,000.00 Business Owner Information Name Role Effective Date Expiration Date LIKNESS, JAY 01/01/1980 LIKNESS, JUDY 01/01/1980 Look Up a Contractor, Electrir;an or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= PUGETSB0000Q 04/14/2008 GENERAL NOTES STAMPS AND APPROVALS , •F" r , J � = = " %' - .'``" ? U T O 4000 Luxottica - - A O Subsidiary T Place of the Mason, Luxottica Drawings Ohio 45040 Location: LI for: Group I. G.G. SHALL REFER TO GENERAL NOTES ON EACH DRAWING SHEET AND INCORPORATE AS A PART OF WORK RESPONSIBILITY. 2. THE GONTRAGTOR I5 RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS BASED ON T1•fE ENTIRE SET OF THESE DOCUMENTS. NO EXTRA COMPENSATION WILL BE GIVEN TO A BIDDER OR SUPPLIER N1-10 HAS BID FROM AN INCOMPLETE SET OF CONSTRUCTION DOCUMENTS. IN CASE OF INCONSISTENCIES OR DISCREPANCIES BETWEEN DRAWINGS THE MOST STRINGENT NOTE OR CONDITION SHALL APPLY. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER IMMEDIATELY OF SUCH DISCREPANCIES. 3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO BIDDING. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES. SUBMISSION OF A BID SHALL CONSTITUTE AN ACKNOWLEDGMENT AND AGGEFTANGE OF ALL EXISTING CONDITIONS. 4. TIE CONTRACTOR 15 RESPONSIBLE FOR MAINTAINING A CURRENT SET OF CONSTRUCTION DRAWINGS ON SITE DURING CONSTRUCTION. THE CONTRACTOR SHALL INDICATE ON 11 ICSE PLANS ALL APPROVED CHANGES TO THE WORK THIS SET OF DRAWINGS SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER WHEN THE PROJECT 15 COMPLETE. 5. IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR ON THESE DRAWINGS, SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER IMMEDIATELY_ 6. NO MATERIAL SUBSTITUTIONS WILL BE ALLOWFP UNLESS SUBMITTED IN WRIITNG TO THE CONSTRUCTION MANAGER MIT THIS LIST TO THE 1. THE CONTRACTOR 15 REQUIRED TO PROVIDE A LIST OF ALL SUBCONTRACTORS TO BE USED AND SUBMIT CONSTRUCTION MANAGER WITHIN 10 WORKING DAYS OF CONTRACT AWARD. PROVIDE A GOP' OF THIS LIST TO 114E STORE MANAGER. 8. REFER TO TENANT / CONTRACTOR RESPONSIBILITY SCHEDULE SHEET T -I.I FOR WORK RESPONSIBILITY. THIS SCHEDULE HAS PRECEDENCE OVER DRAWINGS AND SPECIFICATIONS. 9. THE CONTRACTOR 15 RESPONSIBLE FOR CHECKING AND VERIFYING ALL SHIPMENTS OF CONSTRUCTION MANAGER /TENANT SUPPLIED MATERIALS. THIS INCLUDES VERIFYING PACKING LISTS AGAINST ORDER FORMS MD BILLS OF LADING, NOTING ANY DAMAGE. IF THIS 15 NOT DONE THE CONTRACTOR WILL BEAR THE COST OF ANY EXPEDITED FREIGHT CHARGES TO MEET THE CONSTRUCTION SCHEDULE. THE CONTRACTOR IS RESPONSIBLE FOR FILING DAMAGE REPORTS AND MUST MAINTAIN PACKING MATERIALS FOR SHIPMENT OF DAMAGED ITEMS. BOOKS AND PAPERWORK INCLUDING ALL PACKING SLIPS AND B ILLS OF LADING IN A 10. THE GONTRAGTOR SHALL KEEP ALL HANDBOOKS MARKED ENVELOPE. THIS ENVELOPE 15 TO BE TURNED OVER TO 114E CONSTRUCTION MANAGER. II. 11 GONTRAGTOR SHALL DELIVER TO THE CONSTRUCTION MANAGER A COPY OF THE CERTIFICATE OF OCCUPANCY, LIEN WAIVERS, WARRANTIES, GUARANTEES AND EQUIPMENT OPERATION MANUALS. THE ORIGINAL CERTIFICATE OF OCCUPANCY TO BE FRAMED AND MOUNTED AT STORE MANAGER'S DEK. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DAILY GLEAN UP OF ALL TRADES THROUGHOUT CONSTRUCTION DURATION. 13. THE CONSTRUCTION DOCUMENTS ARE NOT TO BE SCALED ALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED. 14. THESE DRAWINGS ARE NOT TO BE ALTERED IN ANY WAY WITHOUT WRITTEN AUTHORIZATION FROM THE CONSTRUCTION MANAGER OR FROM THE TENANT'S ARCHITECT. 15. MAINTAIN EGRES AT ALL TIMES DURING STORE OPERATION / CONSTRUCTION. 16. COORDINATE CONSTRUCTION TIME AND NOISE REQUIREMENTS WITH f LANDLORD. UPON COMPLETION OF CONSTRUCTION, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO GLEAN ALL FINISH SURFACES / FIXTURES PER MANUFACTURER'S INSTRUCTIONS AND TO EMPLOY THE CERVICES O F A PR G L E ANIN G CO MPANY TO J ASSURE DELIVERY TO THE TENANT OF AN ABSOLUTELY GLEAN STORE. THE FINAL GLEANING 15 TO BE PERFORMED NO MORE THAN ONE DAY PRIOR TO THE TURN OVER IF AN UNTIDY STORE IS D OVER, THE CONSTRUCTION MANAGER RESERVES THE RIGHT TO EMPLOY PROFESSIONAL GLEANING SERVICES AND TO DEDUCT THE COST PLUS 15% FROM THE BALANCE OF THE CONTRACTOR 18. COORDINATE ALL ACTIVITIES WITH LANDLORD PRIOR TO START OF CONSTRUCTION. INTERRUPTION OF SERVICES TO THE E LANDLORD. SHOPPING CENTER OR OTHER TENANTS SHALL BE HELD TO A MINIMUM. COORDINATE SUCH INTERRUPTIONS WITH THE EXISTING SERVICES WHICH ARE IN ANY WAY AFFECTED BY THE PERFORMANGE OF THIS WORK SHALL BE PROTECTED AND MAINTAINED. 11415 INCLUDES UTILITY SERVICES FOR THE SHOPPING CENTER OR OTHER TENANTS THAT ORIGINAL IN OR PASS THROUGH THE TENANT'S SPACE. 11. G.G. TO PROVIDE AND INSTALL TEMPORARY BARRICADE. COORDINATE REQUIREMENTS WITH LANDLORD. 20. INSTALL TEMPORARY ENTRANCE WITH DOORS, FRAMES AND LOCKS. (IF REQUIRED) 21. ALL CONSTRUCTION TO CONFORM TO ALL. APPLICABLE GODES AND ALL APPLICABLE ORDINANCES. WHERE NECESSARY, THE G.G. SHALL BE RESPONSIBLE FOR FILING THE NOTICE OF COMMENCEMENT" IN THE APPROPRIATE OFFICE AND SHALL BE RE TO POST THE "NOTICE OF COMMENCEMENT" AT THE JOB SiTE. 22. ALL WOOD CONSTRUCTION ,ASSOCIATED WITH THIS WORK SHALL BE FIRE RESISTANT TREATED (FRT). ALL NEW FRAMING AT STOREFRONT AND / OR ABOVE CEILING SHALL BE NON - COMBUSTIBLE. 23. CONTRACTOR SHALL COORDINATE ALL EXPLORATIONS / X -RAYS AND CUTTING OF SLAB (IF REQUIRED) WITH LANDLORD PRIOR TO BEGINNING WORK 24. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL OF THEIR WORK AND THE WORK OF THEIR SUBGONTIRACTORS WITH THE STRUCTURE AND SHELL BUILDING ELEMENTS. GONTRAGTOR SHALL IMMEDIATELY NOTIFY THE CONSTRUCTION MANAGER OF ANY PISGRE PANGY BETWEEN THESE DRAWINGS AND BUILDING SHELL 25. CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS AND CONGEALED BLOCKING AS REQUIRED. VERIFY QUANTITY AND LOCATIONS WITH LO WITH LOCAL OFFICIALS. 26. CONTRACTOR WILL LOCATE / RELOCATE SPRINKLER SYSTEM AS REQUIRED BY THE INTENT OF THESE CONSTRUCTION DOCUMENTS. (REFER TO FIRE SPRINKLER SYSTEM NOTES) 21. CONTRACTOR SHALL BE RESPONSIBLE FOR GUTTING AND INSTALLATION OF STUDS, INSERTS AND BLOCKING AS REQUIRED. 28. PROVIDE AND INSTALL DUST PROTECTION AS REQUIRED DURING STORE CONSTRUCTION. 21. CONTRACTOR TO PROVIDE FULL FLOOR PREPARATION AS REQUIRED TO RECEIVE NEW FINISHES. ALL MAJOR FLOOR DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER. 30. EPOS (ELECTRONIC POINT OF SALE) EQUIPMENT AND INSTAI LATION BY TENANT. 31. TELEPHONE EQUIPMENT AND INSTALLATION BY TENANT. 32. CONTRACTOR SHALT. BE RESPONSIBLE FOR COORDINATION OF ALL CEILING WORK WITH ENTIRE DRAWING PACKAGE. 33. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF LIGHTING WITH ELECTRICAL DRAWINGS / REFLECTED CEILING PLAN. 34. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL LIGHT FIXTURE SUPPORTS. 35. G.G. 15 RESPONSIBLE FOR. MAINTAINING REQUIRED FIRE RATINGS AND PROOFING IN ALL INSTANCES. 36. ALL PENETRATIONS OF DEMISING WALLS, ROOF AND FLOOR SHALL BE FIRE SAFER / PROOF PER LOCAL CODES / LANDLORD REQUIREMENTS. 37. G.G. TO RECEIVE, UNLOAD AND PROVIDE SAFE STORAGE OF ALL CONSTRUCTION MANAGER / SUNGLA55 HUT SUPPLIED AND /oil INSTALLED MATERIAL. TRASH REMOVAL OF ALL BOXES /CRATES CONTAINING CONSTRUCTION MANAGER / SUNGLA5S HUT SUPPLIED AND / OR INSTALLED MATERIAL, INCLUDING FLOORING, FIXTURES, HARDWARE, EQUIPMENT ETG. WILL BE BY G.G. 38. G.G. TO PROVIDE TEMPORARY JOB -SITE PHONE AND FAX CAPABLE OF RECEIVING INCOMING GALLS FOR THE DURATION OF THE PROJECT, PROVIDE TELEPHONE NUMBERS TO 1T-IE CONSTRUCTION MANAGER AND ARCHITECT AT CONSTRUCTION START. 31. HAZARDOUS MATERIALS COMMUNICATION PROGRAM: THE G.G. SHALL PROVIDE TO THE CONSTRUCTION MANAGER A COPY OF THEIR HAZARD COMMUNICATION PROGRAM. THE G.G. 15 RESPONSIBLE FOR COMPLIANCE WITH 29 CFR I110.1200(E)(2) OF TF OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR GENERAL INDUS I Kr AND FOR SUBCONTRACTORS AND SUPPLIERS RETAINED BY G.C.. 40. NOTICE OF INCIDENT: G.G. SHALL IMMEDIATELY NOTIFY THE CONSTRUCTION MANAGER OF ANY INCIDENT INVOLVING THE PROJECT HIGH RESULTS IN CONTACT WITH ANY FEDERAL_, STATE OR LOCAL GOVERNMENT AGENCY. 41. STORE GONSIRIJGTION SAFELY POLICY: THE CONSTRUCTION SAFETY POLICY DATED MARCH 17, 1119 15 HEREBY INCORPORATED INTO THIS SCOPE OF WORK. 42. REFER TO SUNGLASS HUT STANDARD PERFORMANCE SPECIFICATIONS. 43. ALL REQUIREMENTS AND REGULATIONS PERTAINING TO THE HANDICAPPED AND OSHA MUST BE INCORPORATED IN THE WORK EVEN THOUGH THEY MAY NOT BE LISTED INDIVIDUALLY AND SEPARATELY IN EITHER THE DRAWINGS OR SPECIFICATIONS. 44. 71-ESE GENERAL NOTES SHALL APPLY TO ALL DRAWINGS AND GOVERN UNLESS OTHERWISE NOTED OR SPECIFIED. 45. UNLESS OTHERWISE SHOWN OR NOTED, ALL TYPICAL DETAILS SHALL BE USED WHERE APPLICABLE. 46. ALL DETAILS SHALL BE CONSIDERED TYPICAL AT SIMILAR LOCATIONS. 47. SAFETY MEASURES: AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF THE PERSONS AND PROPERTY AND FOR ALL INIDEPENDETIT ENGINEERING REVIEWS OF THESE CONDITIONS. THE ARCHITECT'S OR ENGINEER'S JOB SITE REVIEW 15 NOT INTENDED TO INCLUDES REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. : 48. G.G. SHALL FURNISH ONE EMPTY 1DUMP511RR AT STORE TURNOVER TO OWNf3R FOR STORE 5 DISPOSAL OF CARDBOARD, TRASH, ETG. 49. THE GONTRAGTOR SHALL PROVIDE PROTECTIVE COVERING OF ALL EQUIPMENT, MERCHANDISE, CARPET, ETC. DURING AN OPEN STORE RE MODEL. (WHERE APPLICABLE) , _:�'/., �` _ f ( TUKY ^ Y I I J � I LA IA IA A VICINITY PLAN PLOT PLAN SUPERINTENDENT NOTES I. BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY: A.) THE G. SHALL CONTACT THE CONSTRUCTION MANAGER OR THE PERMIT EXPEDITER TO SECURE THE PERMIT AND MOUNT IT IN A VISIBLE LOCATION AT THE SITE B) THE G.G. 15 TO ARRANGE FOR ALL REQUIRED LOCAL INSPECTIONS. 2. DIMENSIONS: 4 = ^ -x , ` ' q ,^ . E - # ` l µ :} ,y - - A mo - j ` , ! € , ' . , �°" � ' ° te', r � � ' ._.. _� - ; . , 1- """" - ! ? .. Ave -1 >--- '- - . . _ ; ` a -_ � :3 w f � 1 - „ • fi . � .�._ � � �• - .. �,., -,. _ _ .� s y 1 "" " 3 � �`' d ^ ' € % ' z i „1 -',�._ .� §xy '. � '."�= ti• • : - 3' _ _ _"_' I i E � ,. � y.x 'fr Ye�' � , y i . 1 [in', �' T _<ry;.L >:.. _ : � : � x: � l ;ice _ , 4.- -_ i = g zr. I I -- ' ll "' : " " °+ s �. t, , ' ' - y : v ri n 4 , : �� r 3 ;� .. w ' .., � ' � 1~ { �` ` ; ? .. � ,_ ... -.�� . ���..4 �a ��� • `' ;: _._ ,: � ` { " x :� r ,�: ;�+�; . P3f1 l t° @: �- °� -• • � t ! . , . . .. � 1_,-- sir w_ , ` T � ,tri . i !' :al � r I Noao5Frou R,nlyd R dtx `� ` DIMENSIONS CANNOT BE MET, PLEASE GALL THE CONSTRUCTION MANAGER FOR DIRECTION. 3. ON -SITE COMMUNICATION: THE G.G. TO CONTACT THE CONSTRUCTION MANAGER TO RESOLVE ALL FIELD ISSUES. 4. CHANGE ORDERS: NO ADDITIONAL COST OR DESIGN CHANGES WILL •BE ACCEPTED WITHOUT THE WRITTE APPROV APPROVAL OF THE CONSTRUCTION MANAGER AND THE EXECUTION OF THE CONSTRUCTION MANAGER'S CHANGE ORDER PROCEDURE ARCHITECT OR RECORD TO BE COPI ED ON ALL CORRESPONDENCE. 5. SUBCONTRACTOR COORDINATION: SUPERINTENDENT NTRA OR CO MUST BE PRESENT AT ALL TIMES DURING CONSTRUCTION DURATION. THE G.G. I5 TO GIVE SUBGONTRAGTORS APPROPRIATE NOTIGE BEFORE REQUIRING THEM ON SITE, COORDINATE INSTALLATION DATES, AND COMMUNICATE SITE SPECIFIC DETAILS, THE G.G. TO p p 11 WORK" WITH THE CONSTRUCTION COORDINATE THE INSTALLATION SCHEDULE AND DIVISION OF CONSTRUCTION SUBCONTRACTORS SUBNTRAGTORS GAN GONTAGT T HE G.G. FOR. SGwEDULE GLARIFIGATIONS. A) MILLWORK/CASEW G.G. TO COORDINATE CRITICAL DIMENSIONS PRIOR TO WALL CONSTRUCTION AND HAVE AREA READY (I.E. WALLS PAINTED, FLOORING COMPLETE) PRIOR TO • - { ! F : p�� � � �GH�566'7 `J ._. S PA GE # 2 1v5 2 �_ n � ` LEVEL OF 3 :.... = - t ,f w ^ r e y r _ l ; " ' �, ■ - . - • ■ . �. ■ # •- ..� °. °.�- � 9� � °: � .� � • .- � � � F �� � ° Tly ��l� f� �. -���! - - . " "� I ` ,i a J ' • ' . ` . ' -� l , ;' r fl� . ...... _ `' -.: � ...A1.- k _ FIXTURE DELIVERY. B.) P05/PHONE .G S, G. TO HAVE TELEPHONE, ELECTRIC AND DATA CABLING INSTALLED (I) WEEK FOR HARDWARE INSTALLATION AND TESTING, GAL IF EOQUDGH TING L THE CONSTRUCTION MANAGER 6. ELECTRICAL AND LIGHTING DELIVERIES: ALL ELECTRICAL DISTRIBUTION, LIGHT FIXTURES, AND LAMPS WILL BE SENT OUT TO TT-EE JOB L COORDINAT ON OF ELIV FOR THE OFF LOADIN O VERI FOR I NY MA AND FOR THE SAFE STORAGE OF THE MATERIAL RECEIVED. 1. METER INSTALLATION (WATER/ELECTRIC /GAS): A) THE CONSTRUCTION MANAGER WILL AUTHORIZE ORIZE INSTALLATION OF ALL METERS ONE (I) WEEK , BEFORE SETDOWN AND COORDINATE THE REMOVAL OF EXISTING OR ADDITIONAL METERS TO 114E 511. I B.) THE G.G. 15 REQUIRED TO GALL THE UTILITY COMPANY TO INITIATE INSTALLATION. 1 G.) THE G.G. 15 REQUIRED TO GALL THE CONSTRUCTION MANAGER IF I) THE STORE REQUIRES A GAS METER, OR 2) THE CONSTRUCTION MANAGER HA5 NOT AUTHORIZED INSTALLATION OF THE e METES FIVE (5) DAYS BEFORE PUNCH. S. PUNCH PROCEDURES: A.) THE G.G. TO CALL THE CONSTRUCTION MANAGER TO CONFIRM THE PUNCH DAL NO LATER THAN TEN (10) WORKING DAYS BEFORE PUNCH. B.) ALL GONSTRJGTION ITEMS INCLUDING ITEMS ON THE INSTALLATION SCHEDULE' TO BE COMPLETED BEFORE PUNCH DAY. G.) THE G.G. SUPERINTENDENT, THE CONSTRUCTION MANAGER AND THE RDO (OR G.M) WILL COORDINATE AND ATTEND THE PUNCH. COPIES OF THE PUNGH TO BE GIVEN TO THE G.M. AND TO THE G.G. SUPERINTENDENT. D.) A SUBSTANTIAL COMPLETION DOCUMENT WILL BE DISTRIBUTED TO THE G.G. ALLOWING A MAXIMUM OF SEVEN (1) CALENDAR DAYS TO COMPLETE ANY /ALL " PUNGH" ITEMS. THE G.G. TO REMAIN ON SITE UNTIL ALL " PUNGH" ITEMS ARE COMPLETE AND TIE STORE G.M. HAS "SIGNED" CONFIRMING COMPLETION OF THE FUNCHLI5T. COPT` OF THE "CONFIRMED" COMPLETION OF PUNGHLI5T WILL BE GIVEN TO THE CONSTRUCTION MANAGER 1. SETDOV N: SGH'S NEW STORE TEAM DELIVERS ALL REMAINING OWNER FURNISHED ITEMS TO THE F - y -. - . � - .i � . i ,•� "� ''. ' - , 1, ;;;:, ,� ; S �� � " 4 � �.= = . � S" '72nd -� 7 ':: � V -- ';� - ' , , :�:_,; , -�, _ �: l - _ ,--T t 1 I St , . �;'' �E � � ' � f _ ,' ,:. ._.. .,.,... BUILDING + CODE DATA DRAWING INDEX NEWED FOR � RE a...r . 7- � a�i Kira O! APPLICABLE- CODES:_ � CD CO!' :' '--- ., -=c-- APPROVED ARCHITECTURAL ALL WORK SHALL CONFORM TO ALL APPLICABLE GOVERNING GODES, INCLUDING, BUT NOT LIMITED TO, 11-fE LATEST EDITIONS OF THE FOLLOWING: BUILDING: 2006 IBC W/ WA AMENDMENTS FIRE: 2006 IFG W/ WA AMENDMENTS MEGHANICAL: 2006 IMO W/ WA AMENDMENTS AGGE55IB ILITY: ANSI 2003 PLUMBING: 2006 UPC W/ WA AMENDMENTS ENERGY: 2003 WA NON RESIDENTIAL FL FGTRIGAL: 2006 NEC W/ WA AMENDMENTS ENERGY CODE OCCUPANT LOAD CALCULATIONS: NOV 3 0 2001 T -I.O GENERAL INFORMATION / COVER SHEET T -II RESPONSIBILITY SCHEDULE . - R -I .0 ARCHITECTURAL. SPECIFICATIONS � � _ Of Tukwila R -I.1 ENGINEERING SPECIFICATIONS B I .. D NG DIVISI . '« N A -1.0 FINISH AND CONSTRUCTION PLAN A -I.1 STORE FIXTURE PLAN A -12 ARCHITECTURAL REFLECTED CEILING PLAN A -2.0 STOREFRONT ELEVATION, PLAN, AND DETAILS A -2J STOREFRONT SECTIONS AND DETAILS A-2.2 LOGO SHEETS A -3.0 INTERIOR ELEVATIONS A -3.I TOILET ROOM ELEVATIONS AND CEILING CONSTRUCTION DETAILS A-4.0 CONSTRUCTION AND INTERIOR DETAILS A -5.0 FIXTURE AXONOMETRIGS MECHANICAL AND PLUMBING SALES FLOOR NON -SALES WALL AREA/MISCELLANEOUS: f VILDING 520 SQUARE FEET - 30 = IS PERSONS 143 SQUARE FEET - 300 = I PERSONS 128 SQUARE i TOTAL OCCUPANT LOAD = 11 PERSONS DATA: TYPE OF TOTAL AREA TOTAL AREA OCCUPANCY ANCY REQUIRED SPRINKLERED: TOTAL EMPLOY1 HANDICAPPED GOLD/ HOT SCOPE OCCUP'ANT FIRE RESISTANCE OF STRUCTURAL EXIT IWIMINATION CONSTRUCTION: TYPE 115 - FULLY SPRINKLERED (PER L.OD,): 800 SQUARE FEET (CALCULATED): -iql FEET CY CLASS: GROUP M - MERCANTILE EXITS: (I) ONE EXIT REQUIRED - (I) ONE EXIT PROVIDED YES/ No . (I) ONE PER SHIFT TOILET: (I) ONE WATER FAUCET: (I) ONE OF WORK` NEW LOAD: 11 PERSONS MAXIMUM TRAVEL DISTANCE TO EXIT = 41 FT. MP-I.0 MECHANICAL PLAN AND SCHEDULES MP -2.0 PLUMBING PLAN AND SCHEDULES MP -3.0 MECHANICAL AND PLUMBING DETAILS MP-4.0 SPECIFICATIONS MP-4.1 SPEGIFIGATIONS SEPARATE PERMIT EEC1TZIGAL REQUIRED FOR: STORE ON THE EVENING OF PUNCH DAY. THE G.G. TO BE ON SITE ON THE DAY Al tK PUNCH, WITH ONE (I) PLUMBER AND ONE (I) ELECTRICIAN TO ASSIST THE SETDOWN TEAM TO RESOLVE ANY ThE G.G. SHALL SUPPLY ONE (1) 20 CUBIC YARD DUMP51 ER FOR REMOVAL OF SETDOWN DE�BR 5I ID. MUZAK SYSTEM: THE G.G. SHALL BE RESPONSIBLE TO CONTACT MUZAK SYSTEMS TWO (2) - THREE (3) WEEKS PRIOR TO THE SCHEDULED DATE, TO ARRANGE FOR THE INSTALLATION OF A GELLING MOUNTED MUZAK SYSTEM WITHIN THE RETAIL AREA OF THE 5Uh1GLA55 HUT STORE. THE G.G. SHALL COORDINATE WITH WORK OF MUZAK WITH THOSE OF OTHER ON SITE TRADES. CONTACT JUDITH SCHOFIELD AT I- 800 - 331 -3340 (X3062) E--LO 9 FCTRICAL POWER PLAN ((Mechanical E -2.0 FL FGTRIGAL REFLECTED CEILING PLAN ' Electrical E -3.0 ELECTRICAL DETAILS E -4.0 SPECIFICATIONS 0 Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION MINIMUM DOOR WIDTH = 32" MINIMUM WIDTH OF AISLES AND CORRIDORS = 36" MINIMUM WIDTH OF STAIRWAY5 = 44" TOTAL DISTANCE TO NEAREST FACILITIES = 43 FT. MAXIMUM TRAVEL DISTANCE TO NEAREST FACILITIES = 300 FT. RATING ELEMENTS: FIRE ENCLOSURE OF EXITS = 2HR EXIST ACC CORRIDORS = IHR TENANT SPACE SEPARATIONS = IHR INTERIOR BEARING WALLS /COLUMNS = 2HR FLOOR CONSTRUCTION INCL. BEAMS = 2HR : CONTACTS TENANT LUXOTTIGA BUILDING TUKWILA PERMIT COUNTER ( HOME OBI 4000 LUXOTTIGA PLACE DEPARTMENT: CONTACT ALLEN JOHANNESEN }E,e p Jam), MASON, OHIO 45040 6300 SOLJTI IGE^NTER BLVD. #100 TUKWILA, WA 98188 TENANT GORTLAND MORGAN ARCHITECT PHONE: (2o6) 431 -3690 ARCHITECT: 111 N. FIELDER RD. ARLINGTON, TX 16012 PHONE: (817) 635 -56Q6 T LIELD FAX (819) 655-5611 COORDINATOR: CONTACT: BROOKE EMERSON 11601 WILSHIRE , BLVD. LOO ANGELES, GA 90025 PHONE: (310) 813 -4183 ENGINEER; T NT 855 MIND GLUE DRIVE FAX: (310) 689-3159 CINCINNATI, OHIO 45215 TEL: (513) 7611 -5588 LANDLORD CASCADE ROOFING FAX: (513) 912 -7122 REQUIRED GONTAGT:BOB PETERSON GONTRAGTOR: 6308 212TH ST. 5W TENANT INTERTEGH DESIGN SERVICES, INC. LYNWODD, WA x8036 PROJECT CONTACT:TRISH NEARHOOF PHONE: 206 -464 --0441 MANAGER: 9100 GARVESR ROAD, SUITE 100 CINCINNATI, OHIO 45242 LANDLORD wsc.0 FIRE PROTECTION (513) 791 -5588 X 111 REQUIRED CONTACT: JOHN GOLDBERG FAX: (513) 192 -7922 GONTRAGTOR 1500 WOODLINVILlIr- REDMOND RD. WOODLINVILLE, WA 18012 BUILDING 13800 TENANT LUXOTTI PHONE: 425 - 821 -9654 CONSTRUCTION CONTACT: JOE SNIDER *COORDINATE WITH LL FOR MANAGER: 4000 LUXOTTIGA PLACE MORE GONTRAGTOR OPTIONS MASON, OHIO 45040 EMAIL: TENANT WESTF JSNI DER@LUXOITIGARETA IL.GOM O JOSH KIMMEL COORDINATOR 11601 WILSHIRE BLVD. Los ANGELES, GA 0 10025% ECEl PHONE: (310) Sa3 - 4761 1= (310) 689-3 -41 NOV - 5 AX: 0 C lair w rwrlen �� O - LANDLORD NOTES EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED A5 SHOWN ON ELECTRICAL DRAWINGS_ FINISH RI= QUIRETLTS FOR MLRGAN la t •_IJPAi�Y P1an review Approval of construction the vioIa Iof of approved -._ �ki gny I � � �, �� A01:24 �toonesa nd ions. • • does not aulhadze :,•:..I,-1. " code ordinance, Receipt Copy F . ;,., , . l8 knovAedged: � )=j(IT ENCLOSURES CORRIDORS= ROOMS (REFER FIRE SPRINKLE EXIT PASSAGEWAYS= GLASS B GLASS G +E ENCLOSED SPACES= GLASS G TO SHT R -I.1 FOR GLASS DESCRIPTIONS D TYPICAL FLAME SPREAD INFORMATION) EE AN SYSTEM: AN AUTOMATIC FIRE SPRINKLER SYSTEM MAIN CURRENTLY EXISTS WITHIN LEASE SPACE. CONTRACTOR SHALL DESIGN THE SYSTEM OFF OF THE EXISTING MAIN AS NECESSARY FOR THE SPACE CONFIGURATION- MODIFICATIONS SHALL BE DEIGNED AND INSTALLED BY QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO SHALL PREPARE AND SUBMIT SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS AND HYDRAULIC CALCULATIONS TO ALL LOCAL GOVERNING AGENCIES AND TO THE LANDLORD FOR THE APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK SHALL BE DONE UNDER SEPARATE PERMIT IN ACCORDANCE WITH ALL LL STATE OR LOCAL GODS HAVING JURISDICTION. a ' 0: City Of TV BUI DING DIVISION REVISIONS No changes shall be made to the Scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submitta l ___ anaY include additional plan review fees . E = EXISTING TO REMAIN SYMBOL LEGEND R = EXISTING TO RELOCATE EXISTING STRUCTURE - ____ LEASE LINE r I. FINI�I NEW STRUCTURE o EXISTING DOORS TO REMAIN. DOOR NUMBER DEMO STRUCTURE a NEW DOOR (SEE DOOR SCHEDULE) X v TAG CODED NOTE FIXTURES © REVISION WALL TAG (SEE WALL SCHEDULE) MS S EC Z007 ANTE 0 sung A Subsidiary of the Luxottica Place M STORE SPACE: SOUTH C TU KW i LA Active Revision Number R� V0 Revisions: Mark Date Description 10-1-01 CLIENT AND LANDLC. 10-H-01 LL, PERMIT, CLIENT Rfr n Seal Title Store Number Intertech Design Se "ceit Inc. 9900 Roads to 100 cIndnnntP, O1-ile:45242 Phone :(513) 79155588 FcxrF(513) 792 7922 e-mail' Intertech@intertechdeslgn.net web' http' / /www.intertechdesIgn.net 711 N FIELWER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 ARCHITECTURAL SYMBOLS' El T.B.D. ❑ T.B.D. H-EVATIOH NO. 51-15ET ND. SCH Standard Version Number: Date . 10 -18 -07 Drawn By • ALR Checked By• DAN 5665 STORE TYPE & LEVEL' NEW LI RELOCATION ® REMODEL El OTH ER STORE VOLUME! HIGH ❑ SMALL MID ❑ OTHER MILLWORK TYPE' ❑ T.B.D. DETAIL NO. 5I-EET NO. NATION NO. X SILT NO 6000A 5665 SCH Project Number Architect's Project No. 07 -0359 E=1■LE=1Z.AL I t c:)1ZM T I OIL/ GONE - - 1 - Sheet Sheet T- 1.3 Of 1 OF 23 ITEM MARK DESCRIPTION SUPPLIED/ INSTALLED MFG./PHONE # MODEL #IGOLOR ALT. #I REMARKS NOTE: ALL 5PEG5 MAY NOT BE USED IN EVERY STORE. ELECTRICAL SPECIFICATIONS GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANGE INSTRUCTIONS. OVAI 20 TO 25 WIRING - TELEPHONE EG / EG EG TO SFl FGT 4 PAIR 22/24 AWG (PLENUM RATED) P -I CADET A.D.A. INTEGRAL TANK TYPE, ELONGATED SIPHON ACTION VITREOUS CHINA, AMERIGAN STANDARD LAUREL *5311.012 CLOSED SEAT WITH GOVER, 3/8 G.P. SUPPLY WITH LOOSE KEY STOP. 1.6 GPF 16/5° MTG. HT. TO BOWL. (ADA COMPLIANT) PG / PG - DATA EG / EG BERK TEK FART #10032201, CATEGORY 5, 4 PAIR UTP (PLENUM RATED) - - - ELEGTRIGAL EG / EG GRAYBAR I (800) 825 -5511 STO- 12 -4GRAY - - SWITGHES - TOGGLE SWITGHES - SINGLE POLE EG / EG HUBBELL OR APPROVED EQUAL GS 1221 GY SERIES 20 AMP, I20 /2TIV / WHITE - - - TOGGLE 5WITGHES - THREE WAY EG / EG HUBBELL OR APPROVED EQUAL G5 1221 GI' SERIES 20 AMP, 120/2T1V / WHITE - - - TOGGLE SWITCHES - LIMITED FRAME EG / EG HUBBELL OR APPROVED EQUAL G5 1221 GY SERIES AMP, 120V / IVORY - - - DIMMER SWITCH - SINGLE LOCATION EG / EG LUTRON OR APPROVED EQUAL NOVA T SERIES, NTB -600, 600 WATTS, INCANDESCENT TYPE / WHITE SLIDING - - - DIMMER SWITCH - TWO LOCATION DIMMING EG / EG LUTRON OR APPROVED EQUAL NOVA T SERIES, NTB -600 BASE UNIT WITH NTA -2 AUXILIARY UNIT, 600 WATTS, INGANDESGENT TYPE / WHITE SLIDING - - RECEPTACLES - DUPLEX RECEPTACLE - 20A, I25V, NEMA 5-20R EG / EG HUBBELL OR APPROVED EQUAL 5362 SERIES, SPEGIFIGATION GRADE, HEAVY DUTY / WHITE - BLAGK AT AREAS WITH P2 FINISH - DUPLEX RECEPTACLE - 20A, I25V, NEMA 5-20R EG / EG HUBBELL OR APPROVED EQUAL 8300 SERIES, HOSPITAL GRADE, HEAVY PUTY 1 WHITE - USE ONLY AS DIRECTED BY LOGAL GODES OR REQUIREMENTS - ISOLATED GROUNDED DUPLEX REGEPTAGLE 20A, I25V, NEMA 5-20R EC 1 EG HUBBELL OR APPROVED EQUAL I6 -5362 SERIES / ORANGE ^ - - - GFI DUPLEX REGEPTAGLE 20A, - HOSPITAL GRADE EG / EG HUBBELL (800) 255 -I03I HUBBELL - NO SUBSTITUTES, USE ONLY WHERE REQU. BY CODE, WHERE REQU. BY EQUIP., OR WITHIN SIX (6) FEET OF A WATER SOURCE / WET AREA. EG / EG HUBBELL OR APPROVED EQUAL - 2320 -A, SINGLE LOCKING / BLACK - MATES WITH HART #62I2 PLUG ( ®1..A8 EQPT #'S: 1,2, 4 4); MATES WITH HART #6212 PLUG EG / EG HUBBELL OR APPROVED EQUAL 8420, SINGLE ^ - PROVIDE 6' CORD AND PLUG AS REQUIRED. TYP STD 60 (I2 -AW0) AND 8421C PLUG (® LAB EQPT #26) rl EG / EG HUBBELL OR APPROVED EQUAL - - PROVIDE 6' CORD AND PLUG AS REQUIRED. TYP STD 60 (I2 -AWG) AND 8421G PLUG (® LAB EQPT 4t26) COVER PLATES - ELEGTRIGAL / DATA / TELEPHONE GOVER PLATES EG / EG HUBBELL OR APPROVED EQUAL. WHITE / PLASTIC - BLACK AT AREAS WITH P2 FINISH FLOOR BOX - FLOOR BOX WITH COVER EG / EC HUBBELL OR APPROVED EQUAL B2521 BRASS STFFL DEEP BOX - IN FLOOR WITH 53325 BRASS STEEL COVER / BRASS WORK SURFACE PORTAL - RECESSED PORTAL WITH (2) DUPLEX REGEPTAGLES EG / EG WIREMOL D KF -I0-B / BLACK - AT SHOW WINDOW PLATFORM BUSWAY - - EG / EG - - - - CONTROLS - TIME SWITCH EC. / EG TORK OR APPROVED EQUAL DG -LOO, 1 DAY SCHEDULING SPDT MAINTAINED CONTACT, 120V GOIL WITH GABINET - - - LIGHTING GONTRAGTOR EG / EC GESGO (513) 326 -2100 GR26OL- SERIES IN NEMA -I ENGLOSURE, 6 OR S POLE, N.O., Fl FGTRICALLY HELD, 120V, COIL, 20A - REFER TO ONE LINE DIAGRAM FOR # OF POLES SIGNALING SERVICES - DOOR BELL EG / EG EDWARDS OR APPROVED EQUAL BELL 340 -4G5, PUSH BUTTON: 600, XFMR: 512 - MOUNT BELL AT 80 ". MOUNT XFMR ABOVE GEILING. MOUNT PUSH BUTTON AT 48 ". - DOOR 15U77FR - REAR ENTRANCE EG / EG EDWARDS OR APPROVED EQUAL BELL 340-05, PUSH BUTTON: 600, XFMR: 532 - MOUNT BUZZER AT SO". MOUNT XFMR ABOVE CEILING. MOUNT PUSH BUTTON AT 48" (FOR WEATHERPROOF PL f SH 9)UON: 1136 -9 DISTRIBUTION - PANEL BOARDS EG / EG GE / GESGO (513) 326 -2100 TYPE AQ FOR 120 /2OSV AND TYPE AE FOR 2T1/48OV. BREAKERS SHALL BE BOLT ON TYPE. - SEE PLANS FOR SCHEDULE - TRANSFORMER EG / EG GE /GESGO (513) 326 -2100 QL TYPE IN NEMA -I ENGLOSURE - TRANSFORMER SHALL BE FLOOR MOUNTED ON ISOLATION PADS - LIGHTING T / EC SEE SHEET E -2.0 - - CONDUIT SUPPORT SYSTEMS - FOR ALL EXPOSED CONDUIT SHALL BE FIRMLY SUPPORTED ON GALVANIZED UNISTRUT OR POWERS - RUT OR HANGERS, ON BRACKETS, HANGERS OR PIPE STRAPS, OR BY BEAM CLAMPS. GG / GG UNISTRUT (800) 541 1453 AS REQUIRED POWERSTRUT, KINDORF - ITEM MARK DESCRIPTION SUPPLIED/ INSTAUED BY MFG./PHONE # MODEL #IGOLOR REMARKS NOTE: ALL 5PEG5 MAY NOT BE USED IN EVERY STORE. PLUMBING SPECIFICATIONS GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS. NOTE: ALL 5PEG5 MAY NOT BE USED IN EVERY STORE. HVAC SPECIFICATIONS GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS. OVAI 20 TO 25 LINEAR SLOT CEILING DIFFUSER - LINEAR DIFFUSER. HEAVY GAUGE EXTRUDED ALUMINUM WITH ISO DEGREE PATTERN ADJUSTMENT, BAKED ANODIG WHITE PAINT GG / GG TITUS (112) 611 -1030 WATER GLOSET P -I CADET A.D.A. INTEGRAL TANK TYPE, ELONGATED SIPHON ACTION VITREOUS CHINA, AMERIGAN STANDARD LAUREL *5311.012 CLOSED SEAT WITH GOVER, 3/8 G.P. SUPPLY WITH LOOSE KEY STOP. 1.6 GPF 16/5° MTG. HT. TO BOWL. (ADA COMPLIANT) PG / PG AMERICAN STANDARD (800) 211 -Ig2q AMERICAN STANDARD 2 (1.6 GPF) - LAVATORY P -2 WALL MOUNTED LUCERNE VITREOUS GHINA WITH 4" CENTERS ANSI 111.1 APPROVED, MONTERREY FAUGET #550I.I10 WITH I -1/4" TAIL PIEGE, 11 GA "P" TRAP, PROVIDE ANGLE STOPS AND WITH 3/S° SUPPLIES INSULATE DRAIN AND SUPPLY LINES WITH TRUEBRO PROTEGTIVE PIPE GOVER SYSTEM #103 WITH WHITE FINISH. PG / PG AMERICAN STANDARD (800) 211 -1g21 AMERICAN STANDARD 0355.012 (4" CENTERS) - MOP BASIN MB MOLDED STONE. FURNISH WITH A FIAT NO. 830AA SERVICE FAUGET WITH INTEGRAL VACUUM BREAKER AND STOPS. SUPPLY A FIAT NO. QDG -3.2 FOR A 2" DRAIN CONNECTION. PG / PG FIAT PRODUGTS (q12) 432 -0525 NO. M5B -2424 - #IPOOI #, #IPO031S, OR IP005# 31 GARPETING MOP SINK 55 FINISH WITH T AND 5 MODEL 5-1110 FAUCET. PROVIDE DRAIN, STOPS AND VAG. BREAKER. PG / PG FIAT PRODUCTS (312) 432 -0525 NO. 12 - MOUNTING HEIGHT - SFT. - COORDINATE LOGATION WITH TENANT EXHAUST FAN WATER HEATER WH -I TANKLES5 INSTANT WATER HEATER, 3 KW, 120V, 1 PHASE. MOUNT ON WALL UNDER LAVATORY. PG 1 PG GHRONOMITE S-30L PLUMBING CONTRACTOR TO COORDINATE W/ ELECTRICAL GONTRAGTOR FOR SPEGIFIC VOLTAGE OF UNIT. PIPING SUPPORTS - WATER HAMMER ARRESTORS PG / PG WATTS /GRAINGER (800) 323 -0620 # 3A55q - FLOOR DRAINS FD-1 MEDIUM DUTY FLOOR DRAIN - NO HUB OUTLET PG / PC JAY R. SMITH 2110 SERIES - FLOOR GLEAN OUT GO GOATED GAST IRON KLEENATRON, INTERNAL GASKETED ABS GLEANOUT PUG, NO HUB CONNECTION AND AAUSTABLE ABS HOUSING WITH SCORIATED SECURED ROUND SATIN NIKALOY TOP. PG / PG JOSAM * 56010 - TYPICAL FLAME SPREAD OF COMMON MATERIALS ITEM MARK DESCRIPTION SUPPLED/ INSTALLED BY MFGJPHONE # MODEL #/COLOR REMARKS NOTE: ALL 5PEG5 MAY NOT BE USED IN EVERY STORE. HVAC SPECIFICATIONS GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS. OVAI 20 TO 25 LINEAR SLOT CEILING DIFFUSER - LINEAR DIFFUSER. HEAVY GAUGE EXTRUDED ALUMINUM WITH ISO DEGREE PATTERN ADJUSTMENT, BAKED ANODIG WHITE PAINT GG / GG TITUS (112) 611 -1030 TITUS/ML -3q TYPE II REFER TO MFGHANIGAL DRAWINGS DIFFUSERS AND GRIT 1 F', - DIFFUSERS, ALUMINUM GONSTR)GTION 1N/A BAKED ON WHITE ENAMEL FINISHED OPPOSED BLADE DAMPER. RETURN AIR GRILLES: ALUMINUM GRID TYPE W/ 1/2" X I /2° GRID AND FRAME W/ BAKED -ON ENAMEL FINISH GG / GG I TITUS (q12) 6q1 -1030 DIFFUSER: MDL. OMNI 24x24 LAY -IN. RETURN: MDL. SOFF 24x24 EGGGRATE REFER TO MECHANICAL DRAWINGS DUGT - FLEXIBLE ROUND DUGT (MAX 10 ") ACOUSTICAL AIRDUGT V- 450 -SDB GG / GG METAFLEX (404) 34q -5300 AGOUSTIGAL AIRDUGT (V- 450 -50B) ALL DUCTS > 10" TO BE SHEET METAL; ALTERNATE SPEG: OWl~NS CORNING FIBERGLASS 800FR/800FRK SMOKE DETECTION - SMOKE DETECTORS GG / GG EDWARDS OR APPROVED EQUAL #IPOOI #, #IPO031S, OR IP005# # VERIFY WITH LANDLORD FOR SYSTEM REQUIREMENTS GARPETING 10 TO 600 THERMOSTAT - 1 DAY PROGRAMMABLE UNIT FOR EAGH HVAG UNIT GG / GG HONEYWELL #T68220 GOMMERGIAL VISION PRO MOUNTING HEIGHT - SFT. - COORDINATE LOGATION WITH TENANT EXHAUST FAN E F -I GELLING MOUNTED EXHAUST FAN/LIGHT FOR TOILET ROOM GG / GG NUTONE 8613RP PROVIDE W/ ROOF GAP OR WALL GAP HVAG EQUIPMENT RTU ELECTRIC HEATING AND COOLING ROOF TOP UNIT LL / GG TRANS AS SPECIFIED ON MEGH. DRAWINGS ENTHALPY CONTROLLED ECONOMIZER, ROOF CURB, POWERED EXHAUST ACCESS DOOR - 1^1B-GP PREMIUM GENERAL PURPOSE ACCESS DOOR GG / GG THE WILLIAMS BROTHERS CORPORATION (416) 2qq -T161 22 "x 22" WHITE BAKED ENAMEL DOOR $ TRIM: 14 6A. STEEL TRIM BEING I -1/2" WIDE. RETURN FRAME: 18 GA. STEEL HAVING A DEPTH OF 1 -3/4 ". TYPICAL FLAME SPREAD OF COMMON MATERIALS MATERIAL FLAME SPREAD SMOKE DEVELOPMENT ITEM GLASS - -FIBER SOUND- ABSORBING PLANKS 15 TO 30 MINERAL -FIBER SOUND- ABSORBING PANELS 10 TO 25 SHREDDED WOOD FIBERBOARD (TREATED) 20 TO 25 SPRAYED CELLULOSE FIBERS (TREATED) 20 TYP TYPICAL ALUMINUM (WITH BAKED ENAMEL FINISH ON ONE SIDE( 5 TO 10 ASBESTOS -GENT BOARD 0 ABOVE ioi BRIGK OR GONGIa.ETE BLOCK 0 CORK 115 GYP. BD. (WITH PAPER SURFACE ON BOTH SIDES) 10 -25 NORTHERN PINE (TREATED) 20 MEGHANIGAL GONTRAGTOR VERT. SOUTHERN PINE (UNTREATED) 130 TO HO PLYWOOD PANELING (UNTREATED) 15-215 PLYWOOD PANELING (TREATED) 100 DRAWING Ib GARPETING 10 TO 600 CONGRETE 0 m Q E EX'G EXISTING ALUM. ABBREVIATIONS GENERAL NoTE.THESE ABBREVIATIONS ARE THROUGH OUT THE ENTIRE SET OF DRAWINGS. ITEM PE LRIPT1ON SMOKE DEVELOPMENT ITEM DESCRIPTION GLASS A 0-25 0-450 GLASS 6 GG GENERAL GONTRAGTOR TYP TYPICAL 0-450 EG Fl FGTRIGAL GONTRAGTOR ABV. ABOVE ioi PG PLUMBING GONTRAGTOR GL'G CEILING MG MEGHANIGAL GONTRAGTOR VERT. VERTICAL T TENANT DWG DRAWING Ib LL LA LO THK. THICK m Q E EX'G EXISTING ALUM. ALUMINUM SIM SIMILAR W/ WITH FINISH CLASSES: DEFINED FINISH FLAME SPREAD SMOKE DEVELOPMENT GLASS A 0-25 0-450 GLASS 6 26 -15 0-450 . GLASS G 16 -200 0-450 REVIEWED FOR CODE COMPLIANCE APPROVED NOV :3 2O7 City Of T uil a BUILDIN DIVISION RECEIVED NOV — 5 2007 PERMIT CENTER 0 sundass hut A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 STORE* 5665 SPACE% 2155 SOUTH CENTER .66. 10 TU KW I LA, WA Active Revision Number Revisions: Mark Date Description 10-1-07 GLINT AND LANDLORD PRELIM 10 -14-01 LL, FERMI, GLIBir REVIEW n R� V0 •P Intertech Design Series Inc. Stephen ELEVATION NO. SHEET NO. SECTION NO. SWEET NO STORE VOLUME' SGH Standard Version Number. 5665 O STORE TYPE & LEVELI HIGH ❑ SMALL MID ❑ OTHER MILLWORK TYPE/ ❑ T.B.D. ❑ T.B.D. ❑ T.B.D. 9 900 Carver, Road•Sulte 100 Cincinnati; "kilo - 45242 Phone(513) 791 -5588 Fax!' Z13) 792 =7922 e - mail' IntertechP_Intertechdeslgn.net web httpi! /wwrdntertecfideslgn.net ! amosi, P.E. pr- .e81onEd ... 8555 Vyoning•Club Drive Cincinnati, Ohlo".45215 Phone, :(513) 791 -5588 Fax0 0513) 792 -7922 e-raA' svaibsl@Intertecb iesign.net tk ARCHITECTURAL SYMBOLS' NEW ❑ RELOCATION REMODEL ❑ OTHER DETAIL HO. SHEET NO. ELEVATION NO. X 51-fEET R: 6000A 5665 SGH Project Number Architect's Project No. 07-0359 Title 1 �� L 1 1 TI O1�lS Date • 10 -18 -07 Sheet Drawn By • Checked By • TMN Store Number R-1.1 Of 4 OF 23 VAV SCHEDULE TAG MAKE MODEL INLET SIZE GFM (MAX.) COOL HEAT GFM (MIN.) TOTAL SP. LOSS V / ? / GY GOMMENTS VAV -I TRANE VPEF -10-0450 _ 10 1100 1100 330 0.1" 211/450/3/60 6.0 KW F1 FGTRIG REHEAT TYPE 1 FRAME I" FILTER * TITUS SOFF AIR BALANGE VENTILATION REQUIRED OA SUPPLIED cis POSITIVE PRESS. 1 GFM DIFFUSER, GRILLE, AND REGISTER SCHEDULE EQUIPMENT SERVICE MOUNTING DESCRIPTION ACCESSORIES FINISH MANUFAGTURER MODEL NO. A SUPPLY GYPSUM BOARD CEILING SINGLE SLOT OBD * TITUS OMNI B RETURN GYPSUM BOARD CEILING TYPE 1 FRAME I" FILTER * TITUS SOFF AIR BALANCE SCHEDULE TAG GFM SUPPLY GFM OUTSIDE GFM EXHAUST VAV -I 1100 1 0 COMMENTS EF -I NUTONE 5613RP EF -I 0 0 100 120/1 BAGKDRAFT DAMPER Total 1100 115 100 AIR BALANGE VENTILATION REQUIRED OA SUPPLIED cis POSITIVE PRESS. 1 GFM 1 GFM FAN SCHEDULE TAG MANUFACTURER MODEL * TYPE GFM T.S.P. (IN.) AMPS VOLTS/PH COMMENTS EF -I NUTONE 5613RP BATHROOM FAN 4 LIGHT 16 0.25 IA 120/1 BAGKDRAFT DAMPER EXISTINIS MALL EXHAUST 5 5 GFM EXISTINIS MALL SUPPLY TRUE NORTH MECHANICAL PLAN SGALE: 1/4" = I' -O" Design Conditions: Summer (degF) 0.ADB. O.A.W.B. I .A.D.B. 1.A.W.B. AIr Ghanges/hr Roof Load Gass Load Wall Load Lights # of People People (sens) M15G. Equip. Total Load Outside Air Required: Total O.A. Supplied: Total AIr Supplied: Temp. of Incoming air: SPACE LOAD CALCULATIONS Tukwila, WA 1S 62 15 62.5 5.0 Heat Gain 5005 0 51 8614 IQ 4150 4146 2Z573 III 21.75 195 1,045 507 55 S5 Winter O.A.DB. 1.AJ2 . Storage Area SaIe5 Area Space Volume BTU/h BTU/h BTU/h BTU/h BTU/h BTU/h REVIEWED FOR CODE COMPLIANCE APPROVED NOV I) 2007 City Of Tukwila BUILDING DIVI ION SPRINKLER NOTES 1. GENERAL GONTRAGTORS FIRE SPRINKLER SUBGONTRAGTOR SHALL DESIGN AND INSTALL FIRE SPRINKLER SYSTEM CONFORMING TO LANDLORD'S CRITERIA, TENANT'S REQUIREMENTS, PER LOCAL GODES AND NFPA STANDARDS. ALL SPRINKLER HEADS IN THE SALES AREA, AND STORAGE SHALL BE PER BUILDING STANDARD. 2. ALL SPRINKLER WORK TO BE DONE BY LANDLORD'S DESIGNATED GONTRAGTOR AT TENANT GONTRAGTOR'S EXPENSE. 3_ CONTRACTOR SHALL GUT HOLES INTO ARGHITEGTURAL METAL GRATES MOUNTED ON GEILINGS IN SHOW WINDOW AREAS WHERE IT OBSTRUCTS SPRINKLER OPERATIONS. 46 10 145 sq.ft. 510 sq.ft. 7,560 Heat Loss 5005 BTU/h 0 BTU/h 468 BTU/h BTU/h 5,473 BTU/h Sales Area (sq.ft.) * 0.50 cfm/sq.ft. Storage Area (sq.ft.) * 0.15 cfm/sq.ft. cfm Set VAV To: cfm (cool) 1100 cfm (heat) 500 (cool) (heat) - COLOR TO MATCH GEILING Q CODED NOTES 0 I. G.G. TO PROVIDE AND INSTALL NEW 7 -DAY PROGRAMMABLE THERMOSTAT WITH 2 DAY TIME CLOCK.. (HONEYWELL OR EQUIVALENT). LOCATE ALL CONTROLLERS AT 60" MAXIMUM A.F.F. AND PROVIDE LOCKING ENGLOSURE. 2. INSTALL TENANT PROVIDED FAN POWERED VAV BOX (VAV -1) MODEL #VPEF- 10 -04S0 WITH ELEGTRIG HEATING. SEE VAV SCHEDULE, THIS SHEET. 3. PROVIDE AND INSTALL TOILET ROOM EXHAUST FAN (EF -I). CONNECT 4" DIAMETER DUCT THROUGH DEMISING WALL AND GONNEGT TO THE MALL PROVIDED 10" DIAMETER EXHAUST DUCT. PROVIDE BACK DRAFT DAMPER. SEE FAN SCHEDULE FOR SPECIFICATIONS. 4. COORDINATE EXACT LOCATION OF DUGTWORK WITH NEW WALL. DUCTWORK TO BE CONGEALED BY GEILING. 5. COORDINATE LOCATION OF NEW AGGESS DOORS WITH EQUIPMENT ABOVE CEILING. VERIFY IN FIELD. 6. VOLUME DAMPER IN VERTICAL. GENERAL NOTES I. ALL OF THE WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRAGTORS SHALL VISIT THE 105 SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THEIR WORK BEFORE BIDDING OR AWARD OF GONTRAGTOR TO INSPECT EXISTING FIF1 T7 GONDITIONS. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NEGESSARY FOR REMOVAL OR RFI.OGATION BY OWNER'S REPRESENTATIVE SHALL BE PART OF THIS CONTRACT, INGLUDING ALL LABOR AND MATERIALS. REPORT ANY CONFLIGTS TO THE ARGHITEGT/ENGINEER (A/E) PRIOR TO THE START OF WORK. 2. THE SUBMISSION OF PROPOSALS SHALL BE CONSIDERED EVIDENGE THAT THE GONTRAGTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE GONTRAGTORS AS GLAIMS FOR EXTRA WORK MADE NECESSARY BY THEIR FAILURE TO VISIT THE SITE. EAGH CONTRACTOR SHALL WARRANT THEIR WORK FOR ONE YEAR FROM THE OPENING DATE OF THE STORE. 4. BIDDING GONTRAGTORS SHALL HAVE A WORKING KNOWLEDGE OF STATE AND LOCAL GODES AND ORDINANCES (INGLUDING SEISMIC SUPPORT OF DUCTS, EQUIPMENT, ETC.) AND SHALL INGLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT AGGORDANGE WITH GOVERNING GODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE GONTRAGTOR SHALL ALERT (A/E) OF ANY APPARENT DISGREPANGIES BETWEEN GOVERNING GODES AND DESIGN INTENT. 5. CONTRACTOR SHALL REVIEW ALL LANDLORD REQUIREMENTS AND INSTALL ALL MATERIALS AND EQUIPMENT AS DIREGTED BY THE LANDLORD'S REPRESENTATIVE AND AS REQUIRED BY THE LEASE DOCUMENTS. CONTRACTORS SHALL VERIFY THE REQUIREMENTS / GONSTRUGTION MANUAL BEFORE SUBMITTING THEIR BID. 6. THE GONTRAGTOR SHALL CONTACT THE A/E PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INGLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE A/E AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GONTRAGTORS GOST. INTERPRETATION OF A/E WILL PREVAIL. 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE MEGHANICAL EQUIPMENT COMPONENTS ARE INSTALLED AT LOGATIONS AND ELEVATIONS WHIGH MAKE THEM READILY AGGESSIBLE FOR ROUTINE MAINTENANGE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES. S. THE OWNER RESERVES THE RIGHT TO GHEGK GONSTRUGTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD THE OWNER FIND GORREGTIVE WORK NECESSARY, HE WILL NOTIFY GONTRAGTOR OF SUCH WORK IN WRITING AND EXPEGT COMPLIANCE PERFORMED WITH DUE DILIGENGE. IF ANY GORREGTIVE WORK 15 DEEMED TO BE NECESSARY, THE COST OF REINSPEGTIONS WILL BE BORNE BY THE GONTRAGTOR. c1. IF W0RK 15 REQUIRED BY OWNER IN ORDER TO IMPROVE, GHANGE OR GORREGT AIR. GONDITIONING OPERATIONAL. CONDITIONS DUE TO: PART MALFUNGTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT GONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY TENANT TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE GONTRAGTOR CAN NOT AGGOMPLISH THE TASK, THEN AFTER. 12 HOURS OF WRITTEN NOTICE, THE OWNER MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACK GHARGE THE GONTRAGTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LAGK OF PERFORMANCE, WORKMANSHIP AND /OR ADHERENGE TO PLANS AND SPECIFICATIONS. LEGEND V.D. r..-r U/G 2 -• —•-2 — —2 SUPPLY DIFFUSER NTH VOLUME DAMPER POINT OF GONNEGTION VOLUME DAMPER DUCT SMOKE DETECTOR UNDERCUT (ALL U/G TO BE 1") EXTRAGTOR GOLD WATER PIPING (GW) HOT WATER PIPING 115° F (HW) EXISTING GOLD WATER PIPING (EX-GIN) EXISTING SANITARY WASTE (EX-IN) NEN SANITARY WASTE (W) NEN VENT (V) (I 1/2" UNLESS NOTED OTHERWISE) 1 O (E VTR RETURN GRILLE WITH VOLUME DAMPER THERMOSTAT INDICATES NEW SUPPLY DUGT INDICATES EXISTING DUGT (FOR SPAGE) INDICATES EXISTING MALL DUGT AGGESS DOOR FLOOR DRAIN (3 "FD) WALL GLEANOUT (INGO) FLOOR GLEANOUT (GO) POINT OF GONNEGTION EXISTING VENT THROUGH ROOF (VTR) RISE DROP RECEIVE NOV - 5 ZOOS 1 usr Sing ' iile ar.�d - • 0 sunOass hut A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 STORE% 5665 SPACE* 2155 SOUTH CENTER A TU KW I LA, WA Active Revision Number Revisions: Mark Date 10 -I-07 10-14-07 /^\ n Seal ARCHITECTURAL SYMBOLS' El SGH Project Number Title R� V0 HIGH MID Store Number Intertech Design gervi ei Inc f 9900 Carver,Road.iSit 100 Clnclnriat1; 11hIo •45242 Phone!,`(513) 7915588 Fax' (513) 792 =722 e na0.� Intertechliintertechdeslgn.net web hope! /www.lnter esign.net Stephen � :; te a •"•� „ Pra(esalonal • 8555Wyor Gull } ' rive Clnclrihriii, Eihlia 45215 Phone'l (513) 791:=5588 Fax "(513) 792 -2922 e -mall' svarioslPIntertec}ideslgn.net 1 t I3EVATiON N0. SFEET NO. MILLWORK TYPE' ❑ T.B.D. ❑ T.B.D. SGH Standard Version Number: 10-12-07 RES SJV Date Drawn By • Checked By- 5665 Description CLIENT AND LANDLORD PRELIM LL, PERMIT, CLIENT REVIEW STORE TYPE & LEVEL' © NEW ❑ RELOCATION REMODEL ❑ OTHER STORE VOLUME' ❑ SMALL ❑ OTHER ❑ T.B.D. 6000A Architect's Project No. 07 -0359 MECHANICAL PLAN AND SCHEDULES Sheet osi, P.E. DETAIL NO. SFET N0. ELEVATION N0. X SKEET No modified to A 5665 v P-1 . o Of 15 OF 23 PLUMBING FIXTURE SCHEDULE NOV -5 2007 MARK DESCRIPTION SUPPLIED BY INSTALLED BY WASTE VENT G JN. H.W. MANUFACTURER MODEL # TRIM $ VALVES REMARKS __ _ P -I WATER CLOSET (ADA) PLUMBER PLUMBER 4" 2" 3/4" - AMER! GAN STANDARD 2 (I.6 GPF) INTEGRAL TANK -TYPE, AMERICAN STANDARD "LAUREL" SEAT MODEL 5311.012 FLOOR MOUNTED, 17" HIGH, VITREOUS CHINA, ELONGATED BOWL, WHITE, INSTALL PER ADA eLiiiviii G ll`r' P -2 LAVATORY (ADA) PLUMBER PLUMBER I -1/2" I -1/2" I/2" I /2" AMER IGAN STANDARD 0355.012 (4" CENTERS) AMERIGAN STANDARD MODEL 5501.110 WRIST BLADE HANDLES VITREOUS GM] NA, WHITE, PROVIDE POP UP DRAIN, ANGLE SUPPLIES, SUPPORT, TRAP WRAP KIT AND P -TRAP, INSTALL PER ADA WH WATER HEATER PLUMBER PLUMBER - - I/2" 1/2" GHRONOMITE SR-50L TANKLESS INSTANT WATER HEATER, 40F TEMP. RISE 0 05 GPM, 3K1A1, 120V /IPH MOUNT BELOW LAVATORY FD FLOOR DRAIN PLUMBER PLUMBER 3" I -1/2" - - JAY R SMITH 2110 SERIES - MEDIUM DUTY FLOOR DRAIN -- NO HUB OUTLET PLUMBING RESPONSIBILITY MATRIX ITEM FURNISHED BY INSTALLED BY REMARKS TENANT OWNER GONTRAGTOR LANDLORD CONTRACTOR SAN, GIN, HW PIP' NG X WATER HEATER AND ASSOGIATED PIPING X GENERAL NOTES: AS A "QUICK" REFERENCE. ALL ITEMS HERE ARE SPEGIFIED DRAWINGS. IF THE GONTRAGTOR ENCOUNTERS ITEMS THAT IT 15 HIS RESPONSIBILITY TO INFORM TENANT'S GONSTRUGTION ITEMS GAN BE CLARIFIED FOR THE CONTRACTOR. THIS SGHEDULE 15 INTENDED AND DETAILED ON THESE ARE CONTRADICTORY THEN MANAGER SO THAT THESE / / / / / / /// / lT/ /n ljllll//l//T//�1I1IIlIIIIIIII MIA I ME I G� I ®IQ.n'�liiil�ll ®1�9'�I TRUE NORTH V L } cN 1 PLUMBING PLAN MP -20 SCALE: I /4" = I'-0" ' OIL 4"INGO P -I 3" 3 /4 "GW 4 "W P -2 ENLARGED PLAN AF SCALE: I/2 "= 1 -O" „marFEnne /2 "GW I /2 "GIN 4 "W U FLOOR 1 ER EX 5"V I: EX- 3 /4 "GW v ENLARGED PLAN x SCALE : 1/2 " 1' -O;; PLUMBING ISOMETRIC SCALE: NONE REVIEWED FOR CODE C OMPLIANCE APPROVED NOV 7) 0 2007 City Of Tukwila B . ILDIN.I�ISION GENERAL NOTES 2. THE SUBMISSION OF PROPOSALS SHALL BE GONSIDERED EVIDENGE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS AS GLAIMS FOR EXTRA WORK MADE NEGESSARY BY THEIR FAILURE TO VISIT THE SITE. 3. EACH GONTRAGTOR SHALL WARRANT THEIR WORK FOR I YEAR FROM THE OPENING DATE OF THE STORE. 4. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF STATE AND LOGAL CODES AND ORDINANGES (INGLUDING SEISMIC, SUPPORT OF DUCTS, EQUIPMENT, ETG.) AND SHALL INGLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT AGGORDANGE WITH GOVERNING GODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE GONTRAGTOR SHALL ALERT (A/E) OF ANY APPARENT DISGREFANGIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 5. CONTRACTOR SHALL REVIEW ALL LANDLORD REQUIREMENTS AND INSTALL. ALL MATERIALS AND EQUIPMENT AS DIRECTED BY THE LANDLORD'S REPRESENTATIVE AND AS REQUIRED BY THE LEASE DOGUMENTS. GONTRAGTORS SHALL VERIFY THE REQUIREMENTS /GONSTRUGTION MANUAL BEFORE SUBMITTING THEIR BID. 6. THE GONTRAGTOR SHALL GONTAGT THE A/E PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HS BID ALL GOSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE A/E AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GONTRAGTORS GOST. INTERPRETATION OF A/E WILL PREVAIL. 8. a. ALL OF THE WORK IS NOT NEGESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THEIR WORK BEFORE BIDDING OR AWARD OF CONTRAGTOR TO INSPECT EXISTING FIELD CONDITIONS. THOSE ITEMS NOT SHOWN OR NOTED BUT WHIGH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER'S REPRESENTATIVE SHALL BE PART OF THIS CONTRACT, INGLUDING ALL LABOR AND MATERIALS. REPORT ANY GONFLICTS TO THE ARGH I TEGT/ENG I NEER (A/E) PRIOR TO THE START OF WORK. ALL WATER LINES, VENT LINES, DRAIN LINES, SPRINKLER LINES, ETG. SHALL BE OFFSET BELOW PLATFORM AND CONGEALED IN WALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETG. THROUGH STORAGE SPACE ABOVE PLATFORM OR ABOVE ELEGTRIGAL EQUIPMENT. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. GENERAL GONTRAGTOR TO COORDINATE WITH LANDLORD WHEN IT 15 REQUIRED TO ENTER OR ALTER ADJACENT TENANT SPACES TO PERFORM WORK REQUIRED. 0 CODED NOTES 0 II. 2" VENT FOR REST ROOM GROUP TO CONTINUE TO MALL VENT SYSTEM. FIELD VERIFY LOCATION AND SIZE. 12. I ts-AP PRIMER FOR FLOOR DRAIN. I. POINT - OF-USE WATER HEATER (WH -I). SEE "PLUMBING FIXTURE SCHEDULE" FOR SPEC. 14. 3/4" WATER LINE GONNEGTS TO EXISTING 3/4" MALL PIPE. FIELD VERIFY LOCATION AND SIZE, 15. 4" SANITARY WASTE LINE. RUN UNDER FLOOR TO 4" MALL WASTE LINE . FIELD VERIFY EXACT LOCATION AND SIZE. 6. FOR GONTINUATION REFER TO DETAIL 3MP -2.0. LEGEND e O (E -) VTR _.T.— . —. -0- - .— . —.—. -c e FLOOR DRAIN (5 "FD) WALL GLEANOUT (WCO) FLOOR GLEANOUT (GO) POINT OF GONNEGTION EXISTING VENT THROUGH ROOF (VTR) RISE DROP SHUT -OFF VALVE PLUMBING EQUIPMENT GOLD WATER PIPING (CIAO HOT WATER PIPING 115° F (HW) EXISTING GOLD WATER PIPING (EX -GW) EXISTING SANITARY WASTE (EX -W) NEW SANITARY WASTE (W) NEW VENT (V) (I I /2" UNLESS NOTED OTHERWISE) 0 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 STORE# 5665 SPACE% 2155 SOUTH CENTER TU KW I LA, WA lEto ;ice Active Revision Number HFV 0 Revisions: Mark Date 10+01 10-14-01 tQ. -. ARCHITECTURAL ELEVA11ON NO. SHEET No. Idass hut Description CLIENT AND LANDLORD PRELIM LL, PERMIT, CLIENT REVIEW Intertech Design Seyices a Inc • 9900 Carver,Road`Sufte 108 Clndnpat170} o$ 242 Phones '(513) 791 -5588 Faxt(513) 792 e�all; IntertechP_Interte esign,net web; ht d Stephen, amosi, P.E. Professional 8555 Vyordn9Clu e Clnclriiiutl, Dhio' Phone x`(513) 79 Fazr` =0513) 792 -7922 e- r;nitt svaeinsl@lntertecNi esignnet SYMBOLS: 5E071014 NO. X X ELEVATION NO' SEC710 Slur NO. © SHEET No. STORE TYPE & LEVEL: © NEW ❑ RELOCATION REMODEL ❑ OTHER STORE VOLUME: HIGH ❑ SMALL ® MID ❑ OTHER MILLWORK TYPO: ❑ T.B.O. ❑ T.B.D. ❑ T.B.D. SGH Standard Version Number. SGH Project Number Architect's Project No. 07 -0359 Title Drawn By • Store Number PLUMBING PLAN AND SCHEDULES . 10 -12 -07 TMN Checked By • SJV Dote 6000A 5665 Sheet DETAIL tJ 2. SI-Eff No. 5665 MP -2� of 16 OF 23 NOTE: HANGERS MUST NOT DEFORM DUCT SHAPE. HANG PER LOCAL SEISMIC REGULATIONS PLY/RETURN DUGT (W/ INSULATI ON) HANGER RODS, WIRES OR STRAPS IN/ VIBRATION ISOLATION (TIP) SUPPLY/RETURN DUGT BAND: I/2 -ROUND MAY BE USED IF DUGT SHAPE IS MAINTAINED FINISHED FLOOR CLAMP PAN TIGHTLY INTO DRAIN SCALE: NONE DUCT RUN SUPPORT 56 " SQ. MIN. ..1111=1 : /\0 FLOOR FLOOR DRAIN SCALE NONE THREADED ROD UNI -STRUT SUPPORT I /4" NEOPRENE VIBRATION ISOLATOR DUGT INSULATION LOCK NUT —DEEP SEAL P -TRAP FLOOR DRAIN STRAINER UGH FLOOR SLAB TER PROOF SEAL/MEMBRANE Virdm/ro/ird►►% %_I % %/ %! /im r: ALL DUCT LINER TRANSVERSE EDGES TO BE COATED IN/ ADHESIVE IN AGGORDANGE IN/ SMAGNA STANDARDS (TYP.) '1 PROVIDE INTERNAL LINER OR EXTERNAL WRAP INSULATION AS SPECIFIED FASTEN W/ MIN. (3 SHT. MTL. SCREWS, SEAL W/ DUGT TAPE AND MASTI G FINISHE FLOOR MAIN DUCT TYP. DUCT TAKE -OFF SGALE: NONE 8 MP-3.0 OMB I NAT ION WYE AND I/5 BEND *I II I II ` CLEAN OUT SCALE: NONE FLANGED AND GPSKETED JOINT OR DUGT GONNEGTION AND RE- ENFORCEMENT IN AGGORDANGE IN/ SMAGNA 2" W.G. GLASS, SEAL NON- GASKETED TRANS- VERSE JOINTS IN AGGORDA■GE W/ SMAGNA GLASS "G" (TYP) TAPE DOWN EXTERNAL LEAN -OUT INSULATI ON ONIGAL OR BELLMOUTH SPIN -- IN FITTING, SEAL AIRTIGHT IN/ MASTIC ANUAL BALANGING DAMPER OUND RIGID DUCT 1" WRAPPED INSULATION 441.1111 AIR FLOW INSULATED ROUND DUCT m DAMPER HANDLE TO BE INSTALLED MAXIMUM OF 5' -0" ABOVE GEILING. IS" LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION. THERMAL INSULATING BLANKET WHERE REQUIRED SUPPLY AIR DIFFUSER LAVATORY INSTANTANEOU WATER HEATER MOUNTED ON WALL BELOW LAVATORY ACCESS GOVER DIFFUSER MOUNTING SGALE: NONE FL PG. CONDUIT AND J--BOX SEE F1 RC,. DRAWINGS SCALE: NONE VOLUME DAMPER LOGATION WHERE DAMPER WOULD BE INACCESSIBLE AT TAKE OFF, PROVIDE IN/ 3" EXTENDED SHAFT, HANDLE AND COLLAR. CTRAP CLAMP (TYP IGAL) OUND FLEXIBLE DUGT CONNECTION, SAME SIZE AS DIFFUSER NECK SIZE (MAX. 5 FT.) FIRE DAMPER INHERE REQUIRED INISHED CEILING TEE BAR OR. MOUNTING FRAME 4 11 r V_ SUPP WA] tK Flu■ L. 1� NOTE: INSULATE EXPOSED PIPING BELOW LAVATORY PER HAAND I GAPPED REQUIREMENTS. INSTANTANEOUS WATER HEATER City 8 ILD - NG DIVISION 1 REVIEWED FOR CODE COMPLIANCE APPROVED NOV :; c 1 2007 TO HOT WATER OUTLET LOW CONTROL TO GOLD WATER OUTLET UAL OUTLET ANGLE VALVE TRAP INISHED FLOOR RF(E VED NUV — 5 2007 PERMIT CENTER 0 sundass hu: A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 STORE# 5665 SPACE* 2155 SOUTH CENTER N _ TU KW I LA, WA Active Revision Number R evisions: Mark Date 10-1-07 10-I� n ARCHITECTURAL SYMB❑L STORE TYPE & LEVEL: • N EW ❑ RELOCATION STORE VOLUME: HIGH ❑ SMALL ® MID ❑ OTH MILLWCIRK TYPI ❑ T.B.D. ❑ T.B.D. ❑ T.B.D. SGH Standard Version Number SGH Project Number Architect's Project No. 07 -0359 Title MEGHANIGAL AND PLUMBING DETAILS . 10 -12 -07 RES Checked By• SJV Date RF V0 REMODEL ❑ OTHER Drawn By • Store Number Intertech la sign Sewices Inc. F 9900 CuryenTIRond' Sufte 100 Clndnnatlru x:45242 Phanea(513) 791 =5588 Fe)a'(513) 7921922 e-nalb Interfechelntertechdeslgn.net rebi httpi/%rw.lntertechdeslgn.net Stephen, � osi, P,E. V-7‘ Wigraialt 8555 Yi,opi g:Club +Drive C kitl, Dhlo 5215 Pho , (513) 791;75588 Fax1C513) 792 -7922 e -rwlU svatiosiVinterteclidesign.net 1 SE✓TION NO. SIFT No. ELEVATION No. SHEET No. 5665 1 Description cL eir Aim LN LORD PRELIM LL, F F11T, CLIENT REVIBV Ark 6000A Sheet DETAIL NO. SHEET NO. ELEVATION NO. x SHEET NO 5665 MP -3.0 of 17 OF 23 rb J DIVISION 15 - MECHANICAL SECTION 15000 MECHANICAL GENERAL PROVISIONS A. GENERAL CONDITIONS I. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT. INCLUDING GENERAL AND SUPPLEMENTARY GONDITIONS AND ALL OTHER SPEGIFIGATION SECTIONS ARE A PART OF THIS CONTRACT AND APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL OTHER TRADES. 3. THE CONTRACTOR 15 RESPONSIBLE FOR PROVIDING HIS SUBCONTRACTORS WITH A FULL SET OF CURRENT DOCUMENTS (INCLUDING SPECIFICATIONS) AND THE COORDINATION OF HIS WORK AND INSPECTIONS OF HIS SUBCONTRACTORS WITH ALL OTHER TRADES ON SITE CONFORMING TO THE GENERAL GONTRAGTOR'S TIME SCHEDULE. 4. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING HIS BID TO DETERMINE CONDITIONS AFFECTING THE WORK. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MOD IFIGATIONS HIGH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RFI _]EVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANGE OF WORK. 5. WHEN USED, THE TERM "PROVIDED BY CONTRACTOR" SHALL BE INTERPRETED AS MEANING "FURNISHED AND INSTALLED" WITH THE EXCEPTION WHERE ITEMS ARE "PROVIDED BY TENANT" WHICH MEANS "FURNISHED ONLY" (INSTALLED BY GONTRAGTOR), EXCEPT AS SPECIFICALLY NOTED OTHERWISE. B. GENERAL REQUIREMENTS I. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY FUNGTIONAL MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, GALLED FOR IN SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AS REQUIRED. FIELD VERIFY THE EXACT TYPE, SIZE AND LOCATION, ETG. OF EXISTING FIFE AND DUCTS IN THE TENANT SPACE PRIOR TO BID. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR GALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR HIGH 15 NEITI IER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH 15 OBVIOUSLY NEGESSARY TO COMPLETE THE WORK, AND HIGH IS USUALLY INCLUDED IN WORK OF SIMILAR GHARAC1 t_R, SHALL BE PROVIDED AS PART OF THE GONTRAGT 3. ALL MECHANICAL WORK SHALL BE INSTALLED 50 AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVI MAINTAINING AND REPAIRING. THE CONTRAGTOR 15 RESPONSIBLE FOR PROVIDING SUFFI ACCESS TO ALL EQUIPMENT FOR SERVICE. G. GODES I. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. ALL- WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL GODES AND ORDINANCES, SAFETY AND HEALTH GODES, NFPA CODES, ENERGY GODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THE GONTRAGTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE GODES, ORDINANCES, AND REGULATIONS. AFTER CONTRACT 15 ISSUED, NO ADDITIONAL COST DUE TO GORE ISSUES SHALL BE REIMBURSED BY THE TENANT TO THE CONTRACTOR. D. LICENSES, PERMITS, INSPECTION AND FEES I. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS AND FEES REQUIRED OR RELATED TO HIS /HER WORK. 2. FURNISH TO THE TENANT'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT SUBSTANTIAL COMPLETION DATE OF PROJECT. E. DRAWINGS I. DRAWINGS (FLANS, SPECIFICATIONS AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS IT 15 NOT POSSIBLE TO INDICATE ALL DUCT AND PIPING OFFSETS, FITTINGS AND ACCESSORIES THAT MAY BE REQUIRED. 2. THE LAYOUT SHOWN ON THE DRAWINGS 15 BASED ON A PARTICULAR MAKE OF EQUIPMENT. IF ANOTHER MAKE OF EQUIPMENT 15 USED WHICH REQUIRES MODIFICATION OR CHANGE OF ANY DESCRIPTION FROM THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE AS PART OF THIS WORK, FOR MAKING ALL SUCH MODIFICATIONS AND CHANGES, INCLUDING THOSE INVOLVING OTHER TRADES WITH THE COST THEREOF INCLUDED IN HIS BID. IN SUCH GASE, CONTRACTOR SHALL SUBMIT DRAWINGS AND SPECIFICATIONS PRIOR TO STARTING WORK SHOWING ALL SUCH MODIFICATIONS AND CHANGES_ HIS PROPOSAL SHALL BE SUBJECT TO THE APPROVAL OF THE TENANT'S CONSTRUCTION MANAGER. F. EXISTING SPACE CONDITIONS I. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING MECHANICAL WORK SHOWN ON THE MECHANICAL DRAWINGS AND THE MEGHANIGAL DEMOLITION SHOWN ON THE ARCHITECTURAL DRAWINGS. DO NOT ABANDON ANY EQUIPMENT. 2. THE CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETG. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJEGT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE GUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR GODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO THE POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. 3. ACTIVE LANDLORD OR OTHER TENANT SERVICES ENCOUNTERED IN WORK SHALL BE PROTECTED AND SUPPORTED. IF EXISTING SERVICES NOT ANTICIPATED REQUIRE RELOCATION, CONTACT THE TENANT'S CONSTRUCTION MANAGER IMMEDIATELY. ALL COSTS FOR REPAIR OF DAMAGES TO ACTIVE LANDLORD OR OTHER TENANT SERVICES DURING CONSTRUCTION SHALL BE PAIR FOR BY THE CONTRACTOR CAUSING THE DAMAGE. 4. TIE -INS AND MODIFICATIONS TO EXISTING LANDLORD SERVICES MUST BE DONE WITH MINIMUM INTERRUPTION OF LANDLORD OPERATION AND DURING HOURS SPECIFIED BY THE LANDLORD. THE GONTRAGTOR 15 RESPONSIBLE FOR CONFIRMING EXACT WORKING HOURS OF THIS WORK WITH THE LANDLORD PRIOR TO SUBMITTING HIS BID. THE CONTRACTOR SHALL INCLUDE IN HIS, ALL PREMIUM TIME REQUIRED TO PERFORM MOD IFI GAT' ONS DURING OTHER THAN NORMAL WORKING HOURS. ALL SUCH WORK MUST BE COORDINATED WITH THE LANDLORD. G. DISCREPANCIES IN DOCUMENTS_ I. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATED THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR 15 RESPONSIBLE TO ADVISE THE TENANT'S CONSTRUCTION MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANT'S CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. H. TRADE NAMES AND MANUFACTURES I. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM STANDARDS FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJEGT TO APPROVAL IN WRITING BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORI7FT7 EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTORS EXPENSE. I. SHOP DRAWINGS I. SUBMIT SIX COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR ALL EQUIPMENT AND DUCT FABRICATION DRAWINGS TO THE TENANT'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO THE ORDERING EQUIPMENT. SUBMISSIONS MUST BE EARLY ENOUGH TO ALLOW THE TENANT'S GONSTRUGTION MANAGER EIGHT WORKING DAYS FOR REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE GENERAL CONDITIONS USING THE MANUFACTURER'S LISTED ON THE DRAWINGS. SHOP DRAWINGS SHALL INCLUDE ALL DATA THAT PERTAINS TO THE REQUIREMENTS SET FORTH ON THE DRAWINGS AND IN THE SPECIFICATIONS THE SUBMITTAL SHALL INCLUDE BUT NOT BE LIMITED TO GUTS OR CATALOGS INCLUDING DESCRIPTIVE LITERATURE AND CHARACTERISTICS OF EQUIPMENT, SHALL SHOW MAJOR. DIMENSIONS, ROUGHING -IN DATA, CAPACITY, CURVES, PRESSURE DROP, CODE COMPLIANCE, MOTOR AND DRIVE DATA AND ELECTRICAL DATA. OBSERVE SPECIAL INSTRUCTIONS WHERE REQUIRED. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL AND SUBCONTRACTOR SHOWING THAT HE HAS REVIEWED AND GONFIRMED SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS TAKE PLACE. LACK OF SUGH CONTRACTOR'S REVIEW AND APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY TENANT'S CONSTRUCTION MANAGER. ALL SHOP DRAWINGS MUST APPEAR IN THE OPERATION AND MAINTENANCE MANUALS LEFT ON SITE AT JOB COMPLETION. 2. TENANT'S CONSTRUCTION MANAGER'S REVIEW OF SHOP DRAWINGS OR SCHEDULES SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS, OMISSIONS OR OTHER DEFICIENCIES OR DEVIATIONS IN THE SHOP DRAWING FROM THE CONTRACT DRAWINGS AND SPEC IFIGATIONS. J. RECORD DRAWINGS I. THE CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE TO REGORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF CONGEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. G. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS. APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S GOORD INATION WITH OTf IER TRADES. D. EXACT ROUTING OF ALL SANITARY AND DOMESTIC WATER PIPING UNDER FLOOR. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. THE DRAWINGS ARE TO BE TURNED OVER TO THE TENANT. K. GUARANTEE I. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHIGH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF AGGEr I ANGE (IN WRITING) OF THE INSTALLATION BY THE TENANT'S CONSTRUCTION MANAGER. PROVIDE EXTENDED WARRANTIES AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. IN CASE OF REPLACEMENT OR REPAIR OR EQUIPMENT DUE TO FAILURE WITHIN GUARANTEE PERIOD, GUARAN I tt ON THAT PORTION OF WORK SHALL BE EXTENDED FOR A PERIOD OF ONE (I) YEAR FROM DATE OF SUCH REPLACEMENT OR REPAIR. L. OPERATIONS MANUALS I. ONE COPY OF EACH OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT FURNISHED ON JOB SHALL BE COLLECTED AND INSERTED IN A 3" THREE RING BINDER AND TURNED OVER TO THE TENANT. EACH NOTEBOOK SHALL INCLUDE BUT NOT BE LIMITED TO INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS, PAMPHLETS OR BROCHURES APPROVED SHOP DRAWINGS AND WARRANTIES OBTAINED FROM EACH MANUFACTURER OF PRINCIPAL ITEMS OF EQUIPMENT. M. SLEEVES I. THE CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE GUT FLUSH WITH EAGH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHIGH SHALL EXTEND 2" ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH GALLIUM SILICATE, SILICON "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, 50 AS TO RETAIN THE FIRE RATING OF THE FLOOR OR WALL. GONFORM TO U.L. ASSEMBLY RATING OF FLOOR OR WALL. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOOR AND PARTITIONS SHALL BE STANDARD WEIGHT 51 t tL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONGEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S. GAUGE GALVANIZED STEEL- MINIMUM. 4. DUCT SLEEVES TO BE MINIMUM 14 GAUGE STEEL. N. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL STEEL SUCH AS ANGLE IRON, BANDS, G- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETG., NECESSARY FOR THE INSTALLATION OF WORK_ 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING OR DUCTWORK. HANGING FROM METAL DECK 15 NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY 170 NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AGGESS DOORS AND OTHER EQUIPMENT SERVICE REQUIREMENTS AND /OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELEGTRIGALLY SEPARATED FROM ONE ANOTHER. 0. AGGESS DOORS I. FURNISH STEEL ACCESS DOORS AND FRAMES, MIN. 16 "X20" OR AS SHOWN ON DRAWINGS, TO GENERAL CONTRACTOR FOR ALL LOCATIONS WHERE NECESSARY TO PROVIDE ACCESS TO CONGEALED VALVES, AND OTHER EQUIPMENT REQUIRING SERVICE OR INSPECTION. LOCATION, TYPE, SIZE AND NUMBER AS DETERMINED BY CONTRACTOR AND APPROVED BY TENANT CONSTRUCTION MANAGER TO SUIT EQUIPMENT REQUIREMENTS. GENERAL CONTRACTOR WILL INSTALL AGGESS DOORS AND FRAMES. 2. AGGESS DOORS LOCATED IN FIRE -RATED WALLS, FLOORS, CEILING -FLOOR OR GEILING -ROOF ASSEMBLIES SHALL BE FIRE RATED, U.L., INC.. LISTED AND LABELED 3. AGGESS DOORS SHALL BE FLUSH TYPE, MANUFACTURED FROM N0.14 GAUGE STEEL, COMPLETE WITH FLUSH FLANGE TYPE FRAMES MANUFACTURED FROM NO. 16 GAUGE STEEL, PROVIDED WITH ANCHORS. AGGESS DOORS SHALL BE SUITABLE FOR INSTALLATION IN WALL OR CEILING MATERIALS SHOWN IN ROOM FINISH SCHEDULES. P. ELECTRICAL MOTORS I. FURNISH, INSTALL AND ALIGN ALL MOTORS REQUIRED FOR THIS EQUIPMENT, UNLESS THEY ARE FACTORY INSTALLED ON UNIT, ALL STARTERS AND ASSOCIATED WIRING AND SAFETY SWITGI ILJ FOR SUCH MOTORS SHALL BE FURNISHED AND INSTALLED BY THE Ft FCTRIGAL CONTRACTOR. STARTERS SHALL MEET ALL REQUIREMENTS AS DEFINED IN THE ELECTRICAL DIVISION OF SPECIFICATIONS. 2. DESIGN, CONSTRUCTION AND PERFORMANCE CHARACTERISTICS OF MOTORS SHALL CONFORM TO ALL APPLICABLE PROVISIONS OF LATEST NEMA, ANSI, ]SEE STANDARDS FOR ELECTRICAL EQUIPMENT. ALL MOTORS SHALL SE SUITABLE FOR OPERATION ON VOLTAGE VARIATION OF PLUS OR MINUS 10%, 40 DEGREES G AMBIENT TEMPERATURE; HAVING A SERVICE FACTOR OF NOT LESS THAN 1.15. Q. LOW VOLTAGE (24 VOLT) WIRING I. THE CONTRACTOR 15 TO INSTALL ALL LOW VOLTAGE WIRING REQUIRED FOR HIS EQUIPMENT. THIS WORK INCLUDES ALL TRANSFORMERS AND DEVICES TO MAKE THIS A GOMPLE I t FUNCTIONAL SYSTEM. 2. ALL WORK 15 TO CONFORM TO THE LATEST ADDITION NEC, AND TO DIVISION 16 Fl FCTRICAL SPECIFICATIONS. 3. ANY CONDUIT REQUIRED BY CODE OR THE LANDLORD HILL BE INSTALLED BY THE ELECTRICAL SUBCONTRACTOR. SECTION 15200 PLUMBING A. SCOPE OF WORK I. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS SHOWN ON THE DRAWINGS, GALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES.) A. GOMPLE I t= SANITARY PIPING SYSTEMS OF WASTE, DRAINS AND VENTS. B. COMPLETE GOLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATI G. PLUMBING FIXTURES AND EQUIPMENT AS SCHEDULED D. TESTS AND ADJUSTMENTS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELEGTRIGAL PLANS AND SPEGIFIGATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OT1 IER CONTRACTORS TO AVOID INTERFERENGES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING WATER, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. PLUMBING EQUIPMENT I. PROVIDE NEW PLUMBING EQUIPMENT AS SHOWN ON THE DRAWING AND SPECIFIED IN THE PLUMBING FIXTURE SCHEDULE. 2. WHERE EXISTING PLUMBING FIXTURES ARE TO BE REUSED, RE BALL GOGK VALVE SEALS, LEAVE IN PROPER WORKING ORDER. G. GENERAL PIPING REQUIREMENTS I. GENERALLY, SANITARY AND POTABLE WATER CONNECTIONS WILL BE MADE AT EXISTING TOILET ROOM. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY THE TENANT'S CONSTRUCTION MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO A MINIMUM OF 50 PSI. 2. INSTALL. ALL NECESSARY PIPE HANGERS, SADDLES AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED A MAXIMUM SPAN OF FIVE FEET. 5. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 4. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE WITH LANDLORD'S CRITERIA. D. PIPING I. SANITARY PIPING - NO PVG ALLOWED A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT, CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STFFI B. JOINTS: BELOW FLOOR SLAB - COMPRESSION TYPE PLASTIC SEAL (HUB AND SPIGOT). ABOVE FLOOR SLAB -- NEOPRENE SEALING SLEEVE WITH STAINLESS STEEL SHIELD AND CLAMP WITH APPROVED NEOPRENE - BASED LUBRICANT, (HUBLESS). GALVANIZED VENT - SGREWED JOINTS WITH TEFLON TAPE ON MALE THREADS. G. PITCH WASTE LINES 3" AND SMALLER NOT LESS THAN 1/4" PER FOOT. PITCH LARGER MAINS NOT LESS THAN I /8" PER FOOT. D. INSTALL A GLEAN OUT AT BASE OF EACH SOIL STACK, AT EACH CHANGE IN DIRECTION, AT INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY LOCAL CODE. GLEAN OUTS SHALL ONLY BE INSTALLED IN NON- PUBLIG AREAS, UNLESS GIVEN EXPRESSED WRITTEN PERMISSION BY TENANT'S CONSTRUCTION MANAGER. WHEN GIVEN PERMISSION TO INSTALL IN PUBLIC AREAS, THE GLEAN OUTS SHALL HAVE STAINLESS STEEL WALL COVERS AND BRASS FLOOR COVERS (FLUSH WITH FINISHED FLOOR) PROVIDED BY THE CONTRACTOR. PROVIDE COVERS WITH INSET AREA FOR CARPETED FLOOR LOCATIONS. ALL GLEAN -OUT LOCATIONS SHALL BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER. E. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. F. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL IO2W "HANDI LAV GUARD" INSULATION KIT. 2. POTABLE WATER PIPING: A. BELOW GRADE: TYPE 'K' ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INGHES AND SMALLER. BRAZE ALL JOINTS. B. ABOVE GRADE: TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT COPPER FITTING AND 15--5 TIN - ANTIMONY SOLDER. G. INSTALL AIR CHAMBER SHOCK ABSORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. D. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE AGGESS DOORS WHERE NECESSARY. E. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. REFER TO PLANS FOR ADD! TI ONAL INFORMATION. F. SECURE PIPE AT ANGLE STOPS. G. PROVIDE FLEXIBLE INSERTS AT ALL PIPE PENETRATIONS THROUGH FRAMING TO KEEP PIPES FROM HITTING FRAME WHEN IN OPERATION. 3. GAS PIPING A. PROVIDE A COMPLETE GAS PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DE I ERMINE IF A GAS SYSTEM 15 REQUIRED. B. LOW PRESSURE (14" W.G. AND BELOW) GAS LINES SHALL BE BLACK 5 1 ttL SCHEDULE 40, ASTM A -120, WITH MALLEABLE THREADED FITTING FOR 2" AND SMALLER, AND WITH WELDED JOINTS FOR 2 -1/2" AND LARGER. MEDIUM PRESSURE (ABOVE 14" W.G.) SHALL HAVE WELDED JOINTS. G. PROVIDE A GAS GOGK, DIRT LEG, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT. PROVIDE GAS METER AND /OR REGULATOR AS REQUIRED. REGULATOR TO BE VENTED TO THE EXTERIOR. D. PITCH PIPING AT A UNIFORM GRADE OF 1/4" IN 15 FEET UPWARD IN DIRECTION OF FLOW. SUPPORT PIPING EVERY 5 FEET_ SUPPORT AS REQUIRED BY LANDLORD CRITERIA, AS DETAILED ON DRAWINGS, OR BY STANDARD INDUSTRY PRACTICE, WHICHEVER IS MORE STRINGENT. E. GAS PIPING EXPOSED ON ROOF MUST BE PAINTED WITH RUST - INHIBITING PAINT. F. INSTALLATION, TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL GODES AND APPLICABLE NFPA 54 CODE-5. G. CONTACT AND COORDINATE GAS SERVICE AND METER REQUIREMENTS WITH THE LOCAL GAS COMPANY AND THE MALL'S MANAGER PRIOR TO BID. 4. TEST AND STERILIZATION A. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: I. TEST POTABLE WATER PIPING AND CONDENSATE PIPING AT 125 PSI& FOR SIX HOURS. 2. TEST DRAIN, WASTE AND VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. ALL JOINTS SHALL BE GAS AND WATER TIGHT. 3. TEST GAS PIPING PER NFPA 54 GODES. 4. STERILIZE POTABLE HOT AND GOLD WATER LINES UPON COMPLETION OF SYSTEM. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. SECTION 15500 FIRE PROTECTION A. SCOPE OF WORK I. THE FP CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL. THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, GALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE WITH NFPA -I3, LOCAL GODES, LANDLORD'S CRITERIA, AND INSURANCE CARRIERS FOR THE MALL AND TENANT. B. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A GOMPLE 1 t SYSTEM. G. DESIGN DRAWINGS, CALCULATIONS, SUBMITTALS AND APPROVALS. D. PERMITS, FEES AND CHARGES. E. TESTS AND TEST CERTIFICATES. F. COST FOR SHUT DOWN FEES. 2. THE CONTRACTOR THAT DOES THE ACTUAL SPRINKLER WORK 15 REQUIRED TO BE A LANDLORD APPROVED SPRINKLER CONTRACTOR. 3. BEFORE STARTING WORK, THE CONTRACTOR SHALL EXAMINE THE ARGHITEGTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENGES AND CONFRONTATIONS. 4. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. 5. INHERE APPLICABLE, DESIGN FOR SEISMIC LOADS PER NFPA 13, 6 -4. 6. ALL WORK TO BE SCHEDULED WITH THE LANDLORD'S FIELD REPRESENTATIVE. ALL SYSTEMS TO BE CHARGED AND OPERATIONAL WHEN CONTRACTOR NOT ON THE PREMISES. B. SHOP DRAWINGS I. THE FIRE PROTECTION CONTRACTOR SHALL PREPARE PETALED SHOP DRAWINGS AND CALCULATIONS FOR HIS WORK. SUBMIT SIX (6) COPIES TO GENERAL GONTRAGTOR FOR APPROVAL. NO WORK SHALL BEGIN UNTIL TENANT'S CONSTRUCTION MANAGER APPROVES HEAD AND PIPING LOCATIONS. 2. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. 3. A COPY OF THE LE 1 tR OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE FORWARDED TO THE LANDLORD'S AGENT AND TO THE TENANT'S CONSTRUCTION MANAGER. C. EQUIPMENT I. SPRINKLER HEADS: A. ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS IN EXISTING STORES TO BE REPLACED), UL., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER CO., GLOBE, GRINNELL, RELIABLE, STAR OR VIKING. 5. ALL SPRINKLER HEADS SHALL BE RATED FOR 165 DEGREES F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL GODES. G. ALL SALES FLOOR HEADS ARE TO HAVE FACTORY APPLIED COLOR FINISH TO MATCH ARCHITECTURAL CEILING FINISH. VERIFY HEAD TYPES AND COLORS WITH TENANT'S CONSTRUCTION MANAGER AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. D. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: I. DRYWALL CEILINGS IN SA1 FS AREA - CONGEALED TYPE (SCREW IN FITTING). 2. LAY IN CEILINGS IN SALES AREA AND CEILINGS IN NON -SALES AREA - SEMI RECESSED TYPE (SCREW IN FITTING). 3. ALL NON -GEILINGED AREAS - BRASS UPRIGHT TYPE (SCREW IN FITTING). NOTE: SEMI- REGESSED HEADS SHALL PROTRUDE NO MORE THAN I" BELOW LEVEL OF CEILING OR SOFFIT. ALL HORIZONTAL SPRINKLER RUNS AT SIDEWALL SOFFITS SHALL BE CONGEALED WITHIN SOFFIT FRAMING. E. SPRINKLER HEADS SHALL HAVE 1/2" ORIFICE AND K- FACTOR OF 5.65. D. GENERAL PIPING I. A FIRE PROTECTION SYSTEM STUB SHALL BE FURNISHED BY THE LANDLORD. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT_ IN "SALES" AREAS AND 100 SQ. FT. IN "NON- SALES" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPING SHALL- BE BASED ON NFPA ORDINARY HAZARD. 2. ALL SPRINKLER LINES SHALL BE INSTALLED GONGEALED, AVOIDING INTERFERENCE NTH LIGHTS, DUCTS, PIPES, STORAGE DEGK, ETG. FIRE PROTECTION GONTRAGTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDIGATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER LINES, LIGHTS, DIFFUSERS, GRILLES AND REGISTERS PRIOR TO INSTALLATION. HORIZONTAL SPRINKLER RUNS AT MERCHANDISE SOFFITS SHALL BE PLACED INSIDE SOFFIT STRUCTURE. VERTICAL DROPS FROM GEILING TO MERCHANDISE SOFFIT SHALL BE LOCATED FLUSH AGAINST DEMISING WALLS. 3. WHERE POSSIBLE REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH GEILING HEIGHTS, EQUIPMENT AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL GOMMON AREAS. REMOVE ALL UNUSED PIPING. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY THE LOCAL FIRE PROTECTION OFFICIAL AND THE TENANT'S CONSTRUCTION MANAGER BEFORE INSTALLATION. HEADS MUST BE LOCATED IN THE CENTER OF GEILING TILES AND IN A SYMMETRICAL PATTERN WITH OTHER CEILING FIXTURES. ADDITIONAL MONIES WILL NOT BE ALLOCATED FOR ADDITIONAL HEADS REQUIRED BY FIELD FIRE INSPECTOR AFTER BIDS ARE ACCEPTED. HEADS IN MERCHANDISE BAYS SHALL BE CENTERED SIDE TO SIDE AND FRONT TO BACK. 5. PROVIDE AND INSTALL A VALVED TEST CONNECTION FOR THE FIRE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR INSURANCE CARRIER. COORD INATE LOCATION WI TENANT'S GONSTRUGTION MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH -IN. 6. SPRINKLER HEADS LOCATED IN STOCK, CORRIDOR ON TOILET ROOM CEILINGS OR WALLS BELOW S' -O" ABOVE THE FINISHED FLOOR ARE TO BE PROTECTED WITH APPROVED GUARDS. RECEIVED Nov 5 2007 PERMIT CENTER A Subsidiary of the Luxottica Croup 4000 Luxottica Place Mason, Ohio 45040 STORE% 5665 SPACE% 2155 SOUTH CENTER INAI A TU KW I L Active Revision Number R� U0 Revisions: Mark Date 10-1-01 10-14-01 7 Title n .■ Seal El El El Store Number 9ung[lass hut A, WA Description CLIENT AND LANDLORD PRELIM LL, PERMIT, CLEW REVIEW Intertech Design Se;' .Viaei Inc. 9900 Carver Road °_Suite 100 Clncirincitl;'Ohld'45242 Phone0(513) 79L5588 Fax' (513) 792=p22 Intentech2IntertechdesIgn.net web' http/AwwwJntertedidesign.net StepheJ Va "` osi, P.E. ARCHITECTURAL SYMBOLS! STORE TYPE & LEVEL] NEW ❑ RELOCATION REMODEL ❑ OTHER STORE VOLUME] 0688104181 Enghefor 8555 iiaipkibilaiibil.iDrIve Clncirinntl, OhIO'45215 Phan `"(513) 791' =5588 Fax! (513) 792 -7.922 e-rwlb svaryos181ntertellesign.net SGH Standard Version Number SGH Project Number 10 -12 -07 CSS & IV Date • Drawn By • Checked By 5665 Sheet HIGH ❑ SMALL MID ❑ OTHER MILLWORK TYPE] ❑ T.B.D. ❑ T.B.D. ❑ T.B.D. DETAIL No. 51-EET NO. ELEVATION NO. x 51•11EET NO 6000A 5665 Architect's Project No. 07-0359 I O 1 �� -- MP -C of 18 OF 23 0 E. PIPING I. SCHEDULE 40, BLACK STEEL PIPE, ASTM A -53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B- 36 -IO -1O FOR WROUGHT STEEL PIPE. 2. GAST IRON OR MALLEABLE IRON SGREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR GAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INGHES. 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INGHES AND SMALLER. 4. VIGTAULIG TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY GODE AND THE LANDLORD. F. TESTS I. WHEN COMPLETED, THE ENTIRE FIRE PROTEGTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RUJ FCi AND REGULATIONS OF THE AUTHORITIES HAVING JURISDIGTION. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEI - CGTS. THE GONTRAGTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS GONTRAGTOR'S EXPENSE. 2. PROPERLY COMPLETED AND SIGNED "SPRINKLER GONTRAGTOR'S MAT tKIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDIGTION AND TENANT'S CONSTRUCTION MANAGER. DIVISION 15 - MECHANIGAL SEGTION 15500 HEATING, VENTILATION AND AIR CONDITIONING A. SCOPE OF WORK I. THE HVAG CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVIGES, TOOLS, TRANSPORTATION AND FAGILITIES NECESSARY FOR REASONABLY IMPLIED AND INGIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MEGHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, GALLED FOR IN THE SPEGIFIGATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER. TO RESPONSIBILITY SCHEDULE FOR EXAGT RESPONSIBILITIES) A. VAV BOXES, HVAG EQUIPMENT, AND APPURTENANCES. B. DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. G. DIFFUSERS, GRILLES, AND REGISTERS. D. GURBS AND STEEL. FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS.) E. TESTING, ADJUSTING AND BALANGING. F. OPERATIONS MANUALS. G. TEMPERATURE GONTROLS AND RELATED DIAGRAMS. H. SEQUENGES OF OPERATION. I. CONNECTION TO ANY LANDLORD ENERGY MANAGEMENT SYSTEM. 2. BEFORE STARTING WORK, THIS GONTRAGTOR SHALL EXAMINE THE ARCHITECTURAL, STRUGTURAL, MEGHANIGAL, AND ELEGTRIGAL PLANS AND SPEGIFIGATIONS TO SEQUENCE, GOORDINATE AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAG SYSTEM, MATERIALS AND EQUIPMENT WITH OTHER GONTRAGTORS TO AVOID I NTERFERENGES AND CONFRONTATIONS. B. HVAG EQUIPMENT I. VARIABLE AIR VOLUME BOXES (VAV) A. WHERE SHOWN ON DRAWINGS, PROVIDE OR REFURBISH AND REUSE VAV BOXES GOMPLETE WITH CONTROLS, HEATING COILS (FANS AS REQUIRED). ALL DUGT CONNECTIONS, FLEXIBLE DUGT/PIPE GONNECTIONS SHALL BE PROVIDED BY THE GONTRAGTOR. VAV BOXES TO BE AS MANUFACTURED BY ENVIRO -TECH, TRANE OR CARRIER AS SGHEDULED. 2. ROOF MOUNTED RELIEF FANS A. WHERE SHOWN ON DRAWINGS, PROVIDE OR REFURBISH AND REUSE EXISTING ROOF MOUNTED RELIEF FANS. PROVIDE NEW MOTORIZED CONTROL DAMPERS. ALL DUGTTNORK, ROOF OPENINGS AND GAPS NECESSARY TO PROVIDE A COMPLE 1 t EXHAUST SYSTEM SHALL BE REUSED OR PROVIDED BY THE GONTRAGTOR. REFER TO PLANS FOR. APPLICABILITY. 3. TOILET EXHAUST FANS A. WHERE SHOWN ON DRAWINGS, PROVIDE OR REFURBISH AND REUSE EXISTING TOILET EXHAUST FAN UNIT COMPLETE WITH GRAVITY BACK DRAFT DAMPERS. ALL DUCTWORK, ROOF OPENING AND CAPS NECESSARY TO PROVIDE A COMPLETE EXHAUST SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR REFER TO PLANS FOR APPLICABILITY. 4. EL F GTR! G DUGT HEATERS A. PROVIDE OR REFURBISH AND REUSE EXISTING ELECTRIC DUGT HEATERS COMPLE 1 t WITH ELEGTRIG HEATING COIL, CONTROLS, AND INTEGRAL THERMOSTAT_ 5. IN -LINE PUMPS A. PROVIDE OR REFURBISH AND REUSE EXISTING 1N -LINE CLOSE COUPLED PUMP(S), BRONZE FITTED, PUMPS, WITH BRONZE CASE WEARING RINGS, BRONZE SHAFT SLEEVE AND MECHANICAL SHAFT SEAL RATED FOR. PUMPS TO BE SO CONSTRUCTED THAT THEY MAY BE MOUNTED IN A HORIZONTAL OR VERTIGAL PIPE LINE. MOTOR TO BE 1 RPM UNLESS NOTED OTHERWISE. 6. VIBRATION ISOLATION DEVIGES A. VIBRATION ISOLATION DEVICES SHALL BE PROVIDED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, ETC.) AND STRUCTURE. B. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. G. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SF! FGTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. D. GHEGK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETG. E. GONSULT MANUFACTURER FOR APPLICATION DATA. 7. CURBS AND STEEL FRAMING FOR SUPPORT A. THIS GONTRAGTOR WILL PROVIDE ALL NECESSARY CURBS AND 51 t_tL FRAMING REQUIRED TO INSTALL ALL HVAG EQUIPMENT AS DESCRIBED OR IMPLIED ON THE DRAWINGS. GURBS SHALL BE A MINIMUM OF 14" HIGH, OF THE SAME MANUFAGTURER OF THE EQUIPMENT SUPPORTED. INSULATE UNDER THE COMPRESSOR SEGTION TO PREVENT CONDENSATION. ALL CURBS MUST BE INSTALLED 50 THAT TOP OF CURBS ARE "DEAD" LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN AGGORDANGE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. G. NEW METAL DUCTWORK - NO FIBERGLASS DUGT ALLOWED. GLEAN AND REUSE EXISTING AND PROVIDE NEW AS SHOWN TO ACCOMPLISH THE FINAL DESIGN. I. NO DUCTWORK SHALL BE FABRICATED PRIOR TO APPROVAL BY THE TENANT'S GONSTRUGTION MANAGER. SIGNIFIGANT DEVIATIONS FROM DESIGN MUST BE APPROVED BY TENANTS GONSTRUGTION MANAGER PRIOR TO FABRICATION OR INSTALLATION. ALL DUGT MAINS ARE TO BE RECTANGULAR UNLESS NOTED OTHERWISE. ALL DUCT BRANCHES TO DIFFUSERS TO BE ROUND RIGID DUGT. (FLEXIBLE DUGT CONNEGTIONS TO THE DIFFUSER ARE NOT TO EXCEED 5' -0") 2. EXCEPT AS OTHERWISE INDICATED, FABRIGAT E AND INSTALL REGTANGULAR DUCTS WITH GALVANIZED SHEET STEEL, IN AGGORDANGE WITH SMAGNA "HVAG DUGT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. CONFORM TO THE REQUIREMENTS IN THE REFERENCED STANDARD FOR METAL THICKNESS, REINFORGING TYPES AND INTERVALS, TIE ROD APPLIGATIONS AND JOIN TYPES AND INTERVALS. 3. EXCEPT WHERE OTHERWISE INDICATED, GONSTRUGT DUGT SYSTEMS TO THE FOLLOWING PRESSURE GLASSIFIGATIONS: (VERIFY WHETHER RETURN OR EXHAUST DUGT 15 POSITIVE OR NEGATIVE PRESSURE). A. SUPPLY DUCTS: 2 INGHES WATER GAUGE, POSITIVE PRESSURE B. RETURN AND EXHAUST DUGTS: 2 INGHES WATER GAUGE, NEGATIVE PRESSURE PRESSURE TEST DUGTS FOR LEAKAGE. REMAKE LEAKING JOINTS AND APPLY SEALANTS AS REQUIRED TO FABRICATE A SYSTEM THAT DOES NOT EXCEED 5% LEAKAGE OR LESS AS STATED BY PRESSURE GLASS RATINGS IN SMAGNA STANDARDS. 4. AS A MINIMUM, GROSSBREAK ALL FLAT SURFACES OR REINFORGE WITH A BEAD APPROXIMATELY 3/8" WIDE X 3/16" DEEP ON 12" CENTERS TO PREVENT VIBRATIONS. 5. INSTALL DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS. b. INSTALL RIGID ROUND AND RECTANGULAR METAL DUGT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSEGTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUGTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 7. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM I -I /2" X I -1/2" X I /8" STEEL ANGLE FRAMES AT EAGH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN THE DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILIGONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 8. ALL TRAVERSE JOINTS AND SEAMS IN SUPPLY AIR DUCT SHALL BE SEALED AIR TIGHT WITH DAP CMC DUGT SEALER. JOINTS ALSO SHALL BE RIVETED OR GONNEGTOD WITH SHEET Mt 1 AL SCREWS_ SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 10. DUGT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPEGIFIGALLY NOTED OTHERWISE. II. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUGTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOGATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY-IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES, AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS AGGESS LOCATIONS. 12. FLEXIBLE CONNECTIONS A. FLEXIBLE COLLARS SHALL BE PROVIDED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, ETG.) AND DUCTS OR GASINGS. ALSO, PROVIDE FLEXIBLE CONNECTIONS WHERE DUCTS GROSS BUILDING EXPANSION JOINTS. B. FLEXIBLE CONNECTIONS SHALL BE GONSTRUGTED OF NEOPRENE- COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. G. FLEXIBLE CONNECTION 15 TO BE RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. 13. FIRE DAMPERS A. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY GODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTIGAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED. B. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 DEGREE F FUSIBLE LINK, TYPE A, A MINIMUM. G. PROVIDE ALL NEGESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND GORE REQUIREMENTS. D. PROVIDE DUGT ACCESS DOORS IN AN AGGESSIBLE LOCATION FOR ALL FIRE DAMPERS. DOOR 15 TO BE 20 GA GALVANIZED DOOR WITH QUICK- OPENING LATCH AND PIANO HINGE. 14. FLEXIBLE AIR DUGT A. FLEXIBLE AIR DUGT SHALL BE I" INSULATED GLASS I AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUGT GONSTRUGTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INGLUDED AS SUCH IN THE BID. B. FLEXIBLE AIR DUGT MAY ONLY BE USED IN VERTIGAL APPLICATIONS WITH PRIOR APPROVAL FROM TENANT'S CONSTRUCTION MANAGER. G. FLEXIBLE DUGT SHALL NOT EXTEND OVER 5' -O" IN LENGTH AT ANY ONE LOCATION. 15. SUPPLY AIR TAKE -OFF FITTINGS A. PROVIDE CONIGAL OR "BELL- MOUTH" TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANGHES. INSTALL PER MANUFACTURER'S INSTRUGTIONS. B. PROVIDE 45 DEGREE RECTANGULAR TAKE -OFFS FROM MAIN DUCTWORK TO RECTANGULAR BRANCHES. 16. DAMPERS A. PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANGH DUGT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. B. INHERE ACCESS TO BALANGING DAMPER 15 RESTRICTED, YOUNG'S REGULATORS SHALL BE USED. G. ALL REGTANGULAR DAMPERS IN OUTSIDE AIR, RELIEF AIR, OR RETURN AIR DUCTS ARE TO BE OPPOSED BLADE TYPE. ALL OUTSIDE AIR DUGT DAMPERS MUST ALSO BE OF THE LOW LEAKAGE TYPE_ D. ALL MOTORIZED DAMPERS NOT FURNISHED WITH EQUIPMENT ARE TO BE HONEYWELL DAMPERS. 17. DIFFUSERS, GRILLES AND REGISTERS A. PROVIDE DIFFUSERS, GRILLES AND REGISTERS AS SCHEDULED DEVICES TO BE COMPLETE WITH DAMPER FRAMES AND ALL AGGESSORIES. FINISH AS I ND I GATED. B. INSTALL ALL AIR DEVIGES AS LOGATED ON THE ARCHITECTURAL REFLECTED GEILING PLAN. G. APPROVED MANUFACTURES: TITUS 15 SPEGIFIED, EQUALS BY METALAIRE OR KRUEGER ARE ACCEPTABLE. D. INTERIORS OF DIFFUSERS AND GRILLES SHALL BE PAINTED MATTE BLACK. 18. MEDIUM PRESSURE DUGT A. WHERE DUGTWORK 15 SPEGIFIGALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONSTRUCTED IN AGGORDANGE WITH SMAGNA STANDARDS FOR A PRESSURE RATING OF 3 INCHES WATER GOLUMN MINIMUM OR LARGER AS REQUIRED BY LANDLORD_ B. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMAGNA STANDARDS FOR MEDIUM PRESSURE DUGT AND WITH THE LANDLORD'S CRITERIA. G. ALL OTHER ITEMS FROM METAL DUGTWORK SPECIFICATION SECTION APPLY TO THIS SEGTION. IQ. DUCTWORK INSULATION - NEW DUGT WORK ONLY A. INSTALL INSULATION PRODUCTS IN ACCORDANGE WITH MANUFAGTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH REGOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA G0A. B. DUGT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INSULATE SUPPLY AND RETURN AIR RECTANGULAR DUGTWORK SHOWN ON PLAN. DUCTWORK SHALL BE INTERNALLY INSULATED WITH I" THICK I -I/2 LB. DENSITY LINER (G =0.28 @ 15 DEGREES F). LINER 15 TO HAVE A COATED SURFAGE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFAGTURER TO PREVENT LINER SEPARATION FROM THE DUGT. ALL TRANSVERSE EDGES TO BE COATED WITH ADI IESIVE. G. ALL ROUND AND OUTSIDE AIR DUGTWORK ABOVE THE GEILING SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF I" THIGK, I -I/2 LB. DENSITY (R =5.6) DUGT WRAP WITH VAPOR BARRIER. VAPOR BARRIER 15 TO BE MAINTAINED THROUGHOUT DUGT SYSTEM. ALL JOINTS MUST BE TAPED 50 THAT NO INSULATION FIBER 15 VISIBLE. EXTEND DUGTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND SIMILAR PENETRATIONS. D. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 50 WHEN TESTED IN AGGORDANGE WITH ASTM G 411, OR AS REQUIRED BY LOGAL GODES. 20. SYSTEM GLEANOUT A. DUGTWORK AND AIR HANDLING EQUIPMENT 15 TO BE GLEANED OUT AND BLOWN OUT BEFORE PAINTING 15 STARTED BY THE GENERAL CONTRAGTOR. B. FILTERS MUST BE IN UNITS AT ANY TIME FANS ARE OPERATED. A GLEAN FILTER MUST BE IN UNIT WHEN THE SPAGE 15 COMPLETED FOR A TURNOVER TO THE TENANT. D. HYDRONIC PIPING I . PROVIDE OR REFURBISH AND REUSE GOMPLt I t HYDRONIG PIPING SYSTEM. 2. PIPING A. HYDRONIC PIPING FOR GHIJ 1 Fn WATER 15 ASTM A -I20, SCHEDULE 40, ERIN, BLAGK STEEL PIPE WITH PLAIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE FIFE 15 2 -1/2 INCH AND LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS OR INSTALL. TYPE "K" ANNEALED TEMPERED COPPER TUBE WITH SILFOS JOINTS FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMANCE WITH ASTM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER 15 MOST STRINGENT. UNIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE REQUIRED. B. ALL PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. G. ALL HYDRONIG PIPING AND EQUIPMENT CONNECTED TO THE HVAG PIPING SYSTEM SHALL BE GLEANED AND FLUSHED. REMOVE, GLEAN, AND REPLACE STRAINER SCREENS. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO GONNEGTION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FROM THE LANDLORD'S SYSTEM UNLESS SPEGIFIGALLY INSTRUGTED TO DO SO FROM THE LANDLORD'S FIELD REPRESENTATIVE. D. PRIOR TO GONNEGTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION FROM THE LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHING, AND PROPER FILLING OF THE TENANT'S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANT'S SYSTEM 15 READY TO BE CONNECTED TO THE LANDLORD'S SYSTEM. 3. VALVES A. GATE VALVES, 2 -INCH AND SMAL I FR. GLASS 150, BODY AND UNION BONNET OF ASTM B 62 GAST BRONZE WITH THREADED OR SOLDER ENDS, INTEGRAL SEAT, RENEWABLE SOLID BRONZE WEDGE DISC, RISING STEM, SCREWED BONNET AND RE- PAGKABLE UNDER PRESSURE. BALL VALVES ARE AGGEPTED AS AN EQUAL SUBSTITUTION. B. GATE VALVES, 2 -1/2 INCH AND LARGER: GLASS 125 CAST IRON BODY, RENEWABLE BRONZE SEATS AND SOLID WEDGE DISG, RISING STEM, FLANGED ENDS, AND RE- PACKABLE UNDER PRESSURE. G. SWING GHEGK VALVES, 2 -INGH AND SMALLER: GLASS 150, GAST BRONZE BODY AND GAP CONFORMING TO ASTM B 62 WITH HORIZONTAL SWING, Y RENEWABLE BRONZE DISC, AND HAVING THREADED OR SOLDERED ENDS. D. SWING CHECK VALVE, 2 -1/2 INCH AND LARGER: GLASS 125 CAST IRON BODY AND BOLTED GAP, HORIZONTAL SWING, RENEWABLE BRONZE DISG, FLANGED ENDS AND CAPABLE OF BEING REFITTED WHILE THE VALVE REMAINS IN THE LINE. E. COMBINATION BALANGING AND SHUT -OFF VALVES: BELL AND GOSSETT GIRGUIT SETTER WITH LOCKING SETPOINT. A GIRGUIT SETTER BALANCE WHEEL MUST BE INGLUDED WITH 0 M MANUAL. F. FLOW METER: BELL AND GOSSETT THERMOFLO INDICATOR MODEL TFI. 4. PIPING SPEGIALTIES A. PRESSURE/TEMPERATURE TEST PLUGS (FETE'S PLUG) - 1/4 INCH NPT FITTINGS TO RECEIVE EITHER A TEMPERATURE OR PRESSURE PROBE, I/8 INCH O.D. FITTING AND GAPS SHALL BE BRASS WITH VALVE GORE OF NORDEL, RATED AT 400 PSIG, OF TO 200 B. STRAINERS - "Y" PATTERN STRAINERS, 125 PSIG, GAST IRON BODY WITH PERFORATED STAIN! FSS STEEL SCREEN, THREADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2 -1/2 INCHES AND LARGER. SCREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INCH FOR CHILLED OR CONDENSER WATER. PROVIDE WITH SLOWDOWN VALVE WITH HOSE END FITTING. G. THERMOMETER - DIE GAST ALUMINUM, Q INGH INDUSTRIAL MERCURY THERMOMETER, FULLY ADJUSTABLE WITH CLEAR AGRYLIG WINDOW AND BRASS SEPARABLE SOCKET. D. MANUAL AIR VENTS - I/8 INGH COIN - OPERATED VENT. PROVIDE AN AIR GHAMBER GONSISTING OF A 3/4 INCH NIPPLE AND BUSHINGS. 5. GENERAL INSTALLATION A. INSTALL WATER MAINS WITHOUT PITCH. USE EGGENTRIG REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. MAKE GHANGES IN DIRECTION WITH FITTINGS. B. BRANCHES TO UNITS BELOW MAIN TO SE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITGHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN I INCH TO 10 FEET. G. HANGERS SHALL BE SIZED AND INSTALLED FRO THE OUTSIDE DIAMETER OF THE INSULATED PIPE. INSTALL 6 LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND PIPE INSULATION. D. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED FROM ONE ANOTHER. E. SEE PLANS FOR APPLICABLE DETAILS. F. ALL PRESSURE PIPING SYSTEMS INSTALLED SHALL CONFORM TO THE REQUIREMENTS OF THE STATE PIPING AND WELDING GODES. G. INSTALL VALVES AT LOW PINTS FOR DRAINING EACH SYSTEM AND INSTALL MANUAL VENTS AT ALL HIGH POINTS OF EQUIPMENT AND PING IN THE SYSTEM TO PROPERLY REMOVE ENTRAPPED AIR. 6. INSULATION A. ALL HYDRONIG PIPING FOR CHILLED WATER AND /OR HEATING WATER, VALVES, FITTINGS, AND AGGESSORIES SHALL BE INSULATED. FOR PIPE SIZES UP TO 2 INCHES, INSULATE WITH I INCH THICK (K =0.23 AT - 15 1/$F FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. FOR PIPE SIZES 2 -1/2 INCHES AND LARGER, INSULATE WITH I -1/2 INGH THICK (K =0.23 AT 5 F) FIBERGLASS INSULATION WITH ALL SERVIGE JACKET AND VAPOR BARRIER. B. INSULATION AT ALL HANGERS FOR PIPING 2 -1/2 INGHES AND LARGER SHALL BE HARD AND NON - COMPRESSIBLE. G. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 TO CONFORM WITH THE REQUIREMENTS OF THE NFPA. E. SYSTEM TESTING, ADJUSTING AND BALANGING I. TESTING, ADJUSTING AND BALANGING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT GONTRAGTOR WHO 15 A GURRENTLY LIGENSED ASSOCIATED AIR BALANCING COUNCIL (AABG) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANGING GONTRAGTOR. NO OTHER BALANGE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANGING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST REGENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING SHALL BE MADE BY THE HVAG GONTRAGTOR. 2. THE HVAG GONTRAGTOR SHALL INSTALL NEW FILTERS IN ALL UNITS PRIOR TO THE AIR BALANCE. THE GOMPLETE AIR BALANGE SHALL TAKE PLAGE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION. 3. BALANGE AIR QUANTITIES TO WITHIN 5% OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED GRANGES IN SHEAVES, BELTS, PULLEYS, OR THE ADDITION OF DAMPERS REQUIRED TO AGHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAG GONTRAGTOR WITH NO ADDITIONAL GOST TO THE TENANT. 4. THE BALANGE REPORT SHALL INGLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. ABC OR NEBB GERTIFIGATION NUMBER AND SIGNATURE OF BALANGING GONTRAGTOR. B. INSTRUMENTATION LIST WITH LAST CALIBRATION DATES. G. MAKE AND MODEL NUMBERS OF ALL HVAG EQUIPMENT TESTED. D. AIR GFM AND STATIC, PRESSURE READINGS (DISCHARGE AND SUGTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. E. MOTOR NAMEPLATE DATA WITH AGTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. F. MOTOR AND FAN RPMS. SHEAVE SIZES AND BELT SIZES. G. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AT FULL GOOLING. H. MAKE AND MODEL NUMBERS OF ALL DISTRIBUTION EQUIPMENT. I. FINAL BALANGED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED.) J. INDEXED PLAN WITH DIFFUSER AND RETURN LOCATION. 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, EGONOMIZER, ETG) AND OPERATING STATUS REGORDED IN THE REPORT. 6. THREE COPIES OF THE BALANGE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO THE TENANT'S GONSTRUGTION MANAGER FOR APPROVAL. - I. THE BALANGING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANGING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED IN THESE DRAWINGS. THE BALANGING CONTRACTOR SHALL REGHEGK ANY ITEMS THAT THE TENANT DEEMS NEGESSARY AT NO ADDITIONAL COST TO THE TENANT. S. FINAL BALANGE REPORT SHALL BE INGLUDED IN THE OPERATION AND MAINTENANGE MANUALS. F. SEQUENCE OF OPERATION - THE CONTRACTOR SHALL REUSE EXISTING AND PROVIDE NEW CONTROL DEVICES AS NEGESSARY TO PROVIDE FOR SYSTEM OPERATION ACCORDING TO THE FOLLOWING: I. START -UP: THE SYSTEM SHALL BE STARTED AND CONTROLLED AUTOMATION. L_Y VIA A TIMEGLOGK OR PROGRAMMABLE THERMOSTAT THAT INDEXES THE EQUIPMENT TO HEATING AND COOLING, OCCUPIED AND UNOCCUPIED MODES OF OPERATION. 2. OCCUPIED MODE: THE VENTILATION FANS SHALL RUN CONTINUOUSLY. SPACE TEMPERATURES SHALL BE MEASURED BY SENSORS LOCATED IN THE SPACE SERVED AND SET ACCORDING TO THE SCHEDULE. THE RESTROOM EXHAUST FAN SHALL OPERATE INTERMITTENTLY AND 15 CONTROLLED BY THE RESTROOM LIGHT SINITGH. 3. COOLING MODE: THE VAV BOXES HALL MODULATE TO MAINTAIN SET POINT TEMPERATT)RES IN THE SPACES. 4. ECONOMIZER OPERATION: N/A FOR TENANT SYSTEM. 5. HEATING MODE: THE VAV BOXES SHALL MODULATE TO MAINTAIN SET POINT TEMPERATURES IN THE SPAGES. 6. UNOGGUPIED MODE: IN THE UNOCCUPIED MODE THE LANDLORD'S VAV AIR WILL STOP, AND THE VAV DAMPERS WILL DRIVE TO THEIR NORMALLY OPEN POSITION. 1. MORNING WARM - OF /GOOL DOWN: AT THE SPECIFIED TIME THE LANDLORD'S VAV WILL PROVIDE WARM AIR TO THE SYSTEM. THE VAV BOXES WILL MODULATE TO MAINTAIN SETPOINT IN THE SPACES. 8. SMOKE EVACUATION: NOT REQUIRED. G. FINAL HVAG INSPECTIONS I. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLAGE, THE TENANT SHALL HAVE THE RIGHT TO HAVE AN INDEPENDENT HVAG CONTRACTOR INSPECT THE FINISHED HVAG INSTALLATION UPON COMPLETION FOR GOMPLIANGE WITH THE PLANS, SPECIFICATIONS AND GODES. THE INSTALLING GONTRAGTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAG GONTRAGTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS AT NO COST TO THE TENANT. REVIE FOR CODE COMPLIANCE APPRO 101 o 200 ILDIN Cif ©t Tukwila RECEIVED NOV - 5 2007 PERMIT CENTER sundass hut A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 STORE% 5665 SPACE% 2155 SOUTH CENTER TUKWILA, WA Active Revision Number Revisions: Mork Date 10-11 10 -19-07 ARCHITECTURAL SYMBULSI El El Title Date R� U0 HIGH MID ❑ T.B.Q. ❑ T.B.D. Drawn By • Checked By Store Number Interte h Design Seces Inc. 9900 carver�;;,l2aacrS to 100 clndnnatl; Dhloh<45242 Phone!'(513) 791:5588 Fax((513) 792 -7792a e -nalb Intertech Jntertechdeslgn.net web+ httplwww.InterteldesIgn.net Stephen P.E. Professional Eridr see 8555 WXo Dl(i1.4I 1rve Clnclrirwitl, Dhlo a4 PhaneiA513) 791 5588 Faxi(513) 792 -7922 e -nalli svamoslEntertecWdesIgnnet ELEVATION F. SflN0. 5EGTION No. No. STORE TYPE & LEVEL: NEW ❑ RELOCATION REMODEL ❑ OTHER STORE VOLUME: MILLWORK TYPO SGH Standard Version Number. 6000A,,, SGH Project Number Architect's Project No. 07 -0359 AP=E =G I I T I O1�lSSr . 10 -12 -07 CSS SJV 5665 Description GUM AND LANDLORD PRELIM LL, EMIT, CLIENT REVIEW 0 ❑ SMALL ❑ OTHER ❑ T.B.D. Sheet \4P PETAL NO. SHEET N0. ELEVATION NO. x SHEET No 5665 Of 1 90E 23