Loading...
HomeMy WebLinkAboutPermit PG07-299 - WESTFIELD SOUTHCENTER MALL - METROPARKMETROPARK 657 SOUTHCENTER MALL PGO7-299 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: City..f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 657 SOUTHCENTER MALL TUICW METROPARK 657 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: MARTHA MARTIN Address: 1327 POST AV STE H , TORRANCE CA Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA Contractor License No: MERIT II163CM DESCRIPTION OF WORK: PLUMBING FIXTURES FOR TENANT RESTROOM Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 $6,000.00 $228.50 Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet PLUMBING /GAS PIPING PERMIT Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) Building sewer and each trailer park sewer 1 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 1 grease interceptors 0 0 Repair or alteration of water piping and/or water 2 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6+) inlets /outlets 0 1 Gas Pininq 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 310 328 -6300 X 104 Phone: 425 883 -9224 Expiration Date: 06/01/2009 PG07 -299 03/19/2008 09/15/2008 PG07 -299 Printed: 03 -19 -2008 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied doc: UPC-10 /06 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us The granting of this permit does not presume to giv authority to violate or cancel the provisions of any other state or local laws regulating construction or erfo c - of work. I am au d to sign and obtain this plumbing /gas piping permit. Date: I r7'4' Permit Number: PGO7 -299 Issue Date: 03/19/2008 Permit Expires On: 09/15/2008 Date: 094 [011/71 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -299 Printed: 03 -19 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond -10/06 METROPARK 1: ** *PLUMBING AND GAS PIPING * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 657 SOUTHCENTER MALL TUKW PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PGO7 -299 ISSUED 11/07/2007 03/19/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -299 Printed: 03 -19 -2008 City of Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: M∎fe167'9 d2 l� /� /c_.c re,n Date: -- PG07 -299 Printed: 03 -19 -2008 \\\km g CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:;%www.ci.tukwila.wa.us King Co Assessor's Tax No.: ' e► 'VT.s1t anz3oy 9 QO Site Address: Wg3 Pffie' 1)j Suite Number: 15 25 Floor: New Tenant: Yes ❑ .. No Tenant Name: 1001,11 V t� r l Property Owners Name: u ` �S'� �� Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Prints* 1 c\ cr�(F. /\ Mailing Address: It( U )1`�%Y BV� • SMX) \()S (f eIJJ Cp c10C.i 2 � City State Zip Name: l V I (At 1 '' Q I �n / � ` ` n Su Day Telephone: 310. �j� � . C�JC O x-f • C' 4 Mailing Address: t. )21 Post P v`I� • S u Ve 14 - 1UY ranee CState PS C! (Zip �S o) City E -Mail Address: _ -- Fax Number: 31 0. 3 . 7 , \-1 Z GENERAL CONTRACTOR : INFORMATION = (Contractor Information for Mechanical ` 4) for , l'lumt ing and Gas Ping (Pg rompan$� Mailing Address: Zip State city Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD -All plan must be wet stamped by Architect of Company Name: D N r V , e31 q fl CO /� c,, ^^ Mailing Address: 10`1 (x(0 Be( nlrirtl Q Ycl n V &in ployv cc � A 1 i City k - NJOY G Day TelephoneT)S 2 . Sq2 • — I 2 E -Mail Address: Fax Number: 7),c 512 . 62-9 Contact Person: ENGINEER OF RECORD - All plans must be wet stamped by Engmeerof Its Company Name: Mailing Address: Y) Pnn Contact Person: tb 1 1) Wnn E -Mail Address: Q: Wpplicaliona\Fonna- Applications On Une 3 -2006 - Permit Appliation.doc Revised: 9 -2006 bb V City Day Telephone: ( 31 - 1 . AIO .2-bS Zip Fax Number: ' f l • lee ZS 1 . `� I Page 1 of 6 Future Type:. Qty Fixture 'Type: Qty " " Fixture Type: " :Future Type: Bathtub or combination bath /shower Drinking fountain or water cooler (per head) ' Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 1., Sinks / Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory 2 Water Closet n 4 Building sewer or trailer park sewer Rain water system - per drain (inside building) Water heater and/or vent / Additional medical gas inlets/outlets - six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas 0' PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: State Zip Valuation of Plumbing work (contractor's bid price): S b d 07 0 Valuation of Gas Piping work (contractor's bid price): S Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Int' I Building Code): 1 S 0c, WV' M...rj Utility Purveyor: Water: Applies immWormo- Appli®tiwu On Lme\3 -2006 - Permit Appfiwtioadoc Revised: 9 -2006 bh City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: p Gym. 6 t 04 tc Yf K-4-5 Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: 9 n U#f ' f Page 5 of 6 Date Application Accepted: I I 1 [alb D Date Application Expires: 5 5 0.40 S Staff Initials: 7110%--1 PERMIT APPLICATION NOTES ; plicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signature: bh Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.12 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.43 Uniform Plumbing Code (current edition). R OR AUT vie ED AGENT: Print Name: a s Ma fl Day Telephone: 51 () .32J? 2 J C+. l Mailing Address: I321 Pat Amp . St4 i+e 1+ Y r y n CO CJSUy City fate Zip Q: \ApplicationsTonne- Appivatons On Imeli -2006 - Permit Application.doc Revised: 9 -2006 Date: l `'O1 ! 2Lfl Page 6 of 6 Dot- RF.C:RP"TS_fR RECEIPT NO: R08 -00824 Initials: JEM User ID: 1165 Payee: METROPARK USA, INC. SET ID: 0319 SET NAME: METROPARK SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us D07 -375 1,236.48 M07 -204 221.66 PG07 -299 186.50 TOTAL: 1,644.64 TRANSACTION LIST: Type Method Description Amount ACCOUNT ITEM LIST: Description BUILDING - NONRES MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE SET RECEIPT Payment Check 33612 1,644.64 TOTAL: 1,644.64 Account Code Current Pmts 000/322.100 1,231.98 000/322.100 221.66 000/322.100 186.50 000/386.904 4.50 TOTAL: 1,644.64 Payment Date: 03/19/2008 Total Payment: 1,644.64 Payee: EXPRESS PERMITS ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: PG07 -299 Address: 633 SOUTRCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/07/2007 Applicant: METROPARK Issue Date: Receipt No.: R07 -02444 Payment Amount: $42.00 Initials: JEM Payment Date: 11/07/2007 01:12 PM User ID: 1165 Balance: $165.50 TRANSACTION LIST: Type Method Description Amount Payment Check 10218 42.00 Account Code Current Pmts 000/345.830 39.50 000/322.100 2.50 Total: $42.00 doc: Receiot -06 Printed: 11 -07 -2007 Project: �� � � � Type of Inspection:�� e d Address 5"'? - a �/ / Date Called: Special Instructions: Date Wanted: 7//5 a.m. P.m. Requester: Phone No: b INSPECTION NO. INSPECTION RECORD Retain a copy with permit P607 - q PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. OMMENTS: 'Inspector: (Date: 7/ El $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: R dPiFP ,a.. =ter z+-i: Project: ��ro ���� Type of Inspection: I; na- Address: 6 5 a/xi ` 1 Date Called: Special Instructions: Date Wanted /�v % ate.. Requester: Phone No: INSPECTION NO. a Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 4 / ;99 PERMIT NO. VL (206)431 -3670 IA Corrections required prior to approval. `COMMENTS: £O rt e(,T lo. t .d 1 A71- G✓v.f.+e 4S ✓'OVA la-a (Date: � / / /ey L., EJ $60.x+ ' EINSPE FEE REQUIRED. Prior to inspection, fee must be pai -t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: /21, 772e Ad.94 de Type of y i ) \ • /A/ 09 /..--62,...„,,h Date Called: Address: 657 i i 1 /9 i ( Special Instructions: Date Wanted: . . . — 7- -- cl....., 0 6z Requester: Phone No: izz:: 1 ■ 0 607--5 INSPECTION NO. 714 T NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-367 El Approved per applicable codes. 'Inspector: (_ El $60.0 paid INSPECTION RECORD Retain a copy with permit 13 Corrections required prior to approval. INSPECTION FEE REQUIRED. Prior to inspection, fee must be 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: 1. Proii;Je. (yv 4„Z46 ,2. Ace) ve-r)-;ce, criAn Nr",(.5 3, See,tAre q_ 4"d / Date:6 A74p 'Receipt No.: 'Date: , , „ Project: AA i ill Tf-,o ari_ Type of Inspection: _,„„. 1 al Address: 65 7 /Ad/ Date Called: Special Instructions: Date Wanted: i a.m. Requester: Phone No:_,,........ 'r-l 925" k21 /z avi9 Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 0 7;297 PERMIT NO. 14, (206)431-367 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: C4 c d4 IDate: I 7,4Ms> L 1$60.0 INSPE ION FEE REQUIRED. Prior to inspection, fee must be ' paid 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project J /_ ro� K n Type of Inspectio l� Address � � ��� Date Called: Special Instructions: Date Wanted: ` /Z3/ a C Requester: Phone No -- - 995" 6 95 - 67 Retain a copy with permit INSPECTION RECORD ��D, � / 7 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 3 ® Approved per applicable codes. El Corrections required prior to approval. 'Date: COMMENTS: O k.- 'Inspector: S - 2 3 --4 g EJ $58.00 RSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Pro»2fr 0�3 Type of Inspection: � gikNO Ga 2r Add ss: i,..._ 7 ��// Date Called: Special Instructions: Date Wan ed: Q © a.m. p.m. Requester: Phone No: 7/6—e .5.- /2 . 2 INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit 'Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ra r rw - outs covvtf 1e,4-( Inspector: ID $58. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Date: spy / Receipt No.: 'Date: Project: 41f 7 e PAO E_ Type ce A Akye 6 ?l/ LeV— Address: 4m57 rii /9 7/ Date Called: Special Instructions: , Date WAnted: P.m. Requester: Phone No: i F/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 1 1--07-29 El Approved per applicable codes. ID Corrections required prior to approval. COMMENTS: 1 > 5&10 1 $58.0 EINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: DEPARTMENTS: GI Buircfng Division Complete Comments: Approved ❑ Notation: Documents/routing slip.doc 2 -28-02 ►�' PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 -299 PROJECT NAME: METROPARK SITE ADDRESS: SOUTHCENTER MALL DATE: 11 -07 -07 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued 1 P li Works I pi') Itii Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Incomplete n Approved with Conditions Planning Division ❑ Permit Coordinator DUE DATE: 11-08-07 Not Applicable C Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT G: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 12 -06-07 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V PRESIDENT 02/14/1984 Bond Amount KIRKWOOD, JOAN M SECRETARY 02/27/2006 FRICKBERG, WILLIAM MICHAEL VICE PRESIDENT 02/27/2006 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License MERITMI163CM MERIT MECHANICAL INC CONSTRUCTION CONTRACTOR 600517946 46817500 CORPORATION PO BOX 2109 REDMOND KING WA 980732109 4258839224 ACTIVE GENERAL UNUSED 2/14/1984 6/1/2009 AUTOMMC044QH https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MERITMI163CM 03/19/2008 GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE CODES REGULATIONS AND LANDLORD'S REQUIREMENTS. 2. DO NOT SCALE DRAWINGS. FIELD VERIFY ALL DIMENSIONS AND JOB CONDITIONS. 3. SHOULD ANY CONDITION ARISE WHERE THE INTENT OF THE DRAWINGS IS IN DOUBT, OR WHERE THERE APPEARS TO BE AN ERROR ON THE DRAWINGS OR A DISCREPANCY BETWEEN THE DRAWINGS AND FIELD CONDITIONS, THE DESIGNER SHALL BE NOTIFIED AS SOON AS POSSIBLE FOR THE PROCEDURE TO BE FOLLOWED. IF THE CONTRACTOR PROCEEDS WITH THE WORK SO AFFECTED WITHOUT INSTRUCTIONS FROM THE DESIGNER, THE CONTRACTOR SHALL MAKE GOOD ANY RESULTING DAMAGE OR DEFECTS. THIS INCLUDES ERRORS IN THE SPECIFICATIONS AND NOTATIONAL ERRORS ON THE DRAWINGS WHERE DOUBTFUL OF INTERPRETATION. 4. IN THE CASE WHERE TWO OR MORE DETAILS APPLYING TO THE SAME PART OF THE WORK ARE IN CONFLICT, THE MOST RESTRICTIVE SHALL GOVERN UNLESS CLARIFIED OR OTHERWISE APPROVED BY THE DESIGNER. 5. THE CONTRACTOR AND EACH SUBCONTRACTOR SHALL CAREFULLY EXAMINE THE CONDITIONS AFFECTING HIS WORK BEFORE PROCEEDING, AND SHALL REPORT TO THE DESIGNER ANY CONDITION WHICH WOULD PREVENT THE PROPER AND LEGAL COMPLETION OF HIS WORK. NOT REPORTING ANY SUCH UNSUITABLE CONDITION WILL CONSTITUTE ACCEPTANCE OF ALL CONDITIONS BY THE CONTRACTOR AND /OR SUBCONTRACTOR. 6. APPROVAL OF SHOP DRAWINGS MEANS APPROVAL OF THE GENERAL METHOD OF FABRICATION ONLY. DIMENSIONS AND QUANTITIES MAY NOT BE CHECKED, AND APPROVAL OF SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS UNLESS SPECIFICALLY INDICATED IN THE APPROVAL. 7. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. WHERE DRAWINGS AND SPECIFICATIONS CONFLICT, THE MOST RESTRICTIVE SHALL APPLY. 8. LANDLORD'S BUILDING IS FULLY SPRINKLERED CONSTRUCTION. 9. PROVIDE 2A,10BC MINIMUM RATED FIRE EXTINGUISHER TO BE LOCATED WITHIN 75 FEET OF TRAVEL DISTANCE FROM ALL AREAS. PROVIDE ONE EXTINGUISHER FOR EACH 75 FEET OF TRAVEL. 10. PLANS OF ALTERATIONS TO EXISTING SPRINKLER SYSTEM SHALL BE APPROVED BY THE FIRE DEPARTMENT PRIOR TO INSTALLATION OF SYSTEM. 11. DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOF SHALL BE PROVIDED. EXITS, EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS AND EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED BY DECORATIVE MATERIAL (UFC 11.204). 12. A "THIS DOOR IS TO REMAIN UNLOCKED DURING BUSINESS HOURS" SIGN, WITH A MINIMUM ON (1) INCH HIGH LETTERS SHALL BE PROVIDED ADJACENT TO FRONT EXIT DOOR. PROVIDE INDICATIONG TYPE LOCKS ON DOORS. 13. NO HAZARDOUS MATERIALS, LIQUIDS OR CHEMICALS SHALL BE STORED OR USED WITHIN THE SUBJECT BUILDING AS TO REQUIRE A HAZARDOUS CLASSIFICATION PER APPLICABLE UNIFORM BUILDING CODE. 14. ALL INTERIOR WALLS AND PARTITIONS SHALL BE DESIGNED AND CONSTRUCTED TO RESIST ALL LOADS TO WHICH THEY ARE SUBJECTED BUT NOT LESS THAN A FORCE OF 5 POUNDS PER SQUARE FOOT APPLIED PERPENDICULAR TO WALLS. 15. ALL EXITS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 16. LIGHT, VENTILATION AND SANITATION SHALL COMPLY WITH SECTIONS OF APPLICABLE BUILDING CODES. 17. DOORS SHALL HAVE A CLEAR OPENING OF NO LESS THAN 32" WHEN OPEN AND BE OPERABLE BY A SINGLE EFFORT. 18. THE FLOOR INSIDE OR OUTSIDE OF A DOORWAY SHALL BE LEVEL FOR A DISTANCE OF 5' -O" FROM THE DOOR, IN THE DIRECTION OF THE DOOR SWING, AND SHALL EXTEND 18" BEYOND THE LATCH SIDE FOR INTERIOR DOORS AND 24" BEYOND THE LATCH SIDE FOR EXTERIOR DOORS. 19. SWITCHES AND CONTROLS FOR LIGHTS, VENTILATION, FIRE ALARMS, ETC. MUST BE PLACED NO MORE THAN 48" FROM THE FLOOR. 20. A 7' -0" MINIMUM VERTICAL CLEARANCE 15 REQUIRED FROM THE FLOOR TO CEILINGS OR PROTRUDING WALL FIXTURES. 21. PROPOSED TOILET TO MEET HANDICAPPED REQUIREMENTS AS FOLLOWS: a. PROVIDE A SMOOTH, NON - ABSORBENT FLOOR FINISH - SHEET VINYL WITH A CONTINUOUS 5" HIGH COVE BASE EXTENDING UP THE WALL. b. WALLS WITHIN WATER CLOSET COMPARTMENTS AND WITHIN 2' -O" OF THE FRONT AND SIDES OF URINALS TO A HEIGHT OF 4' -0" SHALL BE FINISHED WITH PORTLAND CEMENT PLASTER OR AN ICBO APPROVED WATER RESISTANT DRYWALL COVERED WITH CERAMIC TILE OR OTHER APPROVED COVER MATERIALS. c. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. d. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, OR PINCHING OR TWISTING OF THE WRIST. 22. THE NUMBER OF EMPLOYEES PER SHIFT SHALL NOT EXCEED FOUR(4). 23. PROVIDE FIRE STOPPING AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES. 24. PLANS FOR ALL FIXED FIRE PROTECTION EQUIPMENT SUCH AS STANDPIPES, SPRINKLER SYSTEMS AND FIRE ALARM SYSTEMS, ETC.. MUST BE SUBMITTED TO, AND APPROVED BY, THE FIRE PREVENTION BUREAU BEFORE THIS EQUIPMENT IS INSTALLED. SPACE #1525 SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TUKWILA, WA 92188 REVISIONS No changes shall be made to the scope o f work without prior approval of Tukwila Building Division. NOTE: Revisions will adeq additional plan rev lan w tees may include a SEPARATE PERMIT REQUIRED FOR: 1.911 eohanlea! Lam! Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila BL6 +I. - fl!r;n P1VlsioN KEY PLAN PROJECT ADDRESS: M E T R O P A R K SPACE #1525 SOUTHCENTER MALL 633 SOUTCENTER PARKWAY TUKWILA, WA 98188 -2888 LEVEL 1 SEARS GENERAL CONTRACTOR GENERAL REQUIREMENTS GENERAL CONTRACTORS' SUPERINTENDENT MUST HAVE A LAPTOP COMPUTER CAPABLE OF E- MAILING WEEKLY UPDATE REPORTS AND PHOTOGRAPHS ON POWERPOINT OF JOB PROGRESS TO METROPARKS PROJECT MANAGER AND ARCHITECT /PROJECT COORDINATOR. THIS UPDATE MUST BE SENT IN EVERY FRIDAY BY NOON EST. PHOTOS TO INCLUDE: STOREFRONT /BARRICADE, SALES AREA, FITTING ROOMS, NON SALES, RESTOOMS; FRAMING, ELECTRICAL, HVAC, PLUMBING, AND ANY UNDERGROUND WORK IN PROGRESS. AT COMPLETION OF PROJECT, BUT PRIOR TO MERCHANDISING, A COMPLETE SET OF PHOTOS MUST BE TAKEN OF ENTIRE PROJECT. THESE PICTURES TO INCLUDE: STOREFRONT AND SIGNAGE WITH POWER ON TO SIGN IF ILLUMINATED. SALES AREA AND FIXTURES, CASH WRAP, FITTING ROOMS, NON SALES, ELECTRICAL INDICATING LOCKOUTS ETC. BY REVIEWED CODE COMPLIANCE APPROVED NOV 3 0 2007 Of Tukwila iSIQN B . ILDIN . . DIVISION S FILE COPY Permit Na Plan review approval la aubjectft wore aid arm. Approval of construction documents dose not aulhodze the violation of any adopted code or ordinal= Receipt of approved. Copyand • /1 City of Tukwila BUILDING DIVISION NOT TO SCALE INDEX OF DRAWINGS T.1 T.1.1 R.1 A.1 A.2 A.2.1 A.3 A.3.1 A.4 A.5 A.6 A.7 A.S A.9 A.10 A.11 M.1 M.2 M.3 E.1 E.2 E.3 E.4 E.5 KEY PLAN, VICINITY MAP, PROJECT DATA RESPONSIBILITY SCHEDULE SITE PLAN (FOR REFERENCE ONLY) FLOOR PLAN, NOTES REFLECTED CEILING PLAN, LIGHT FIXTURE SCHEDULE DIMENSIONED REFLECTED CEILING PLAN INTERIOR ELEVATIONS INTERIOR ELEVATIONS, TOILET DETAILS & FITTING ROOM DETAIL FINISH FLOOR PLAN, E NISH SCHEDULE, VENDORS STOREFRONT PLAN DETAIL AND ELEVATION STOREFRONT SECTIONS & DETAILS FIXTURE /EXITING PLAN AND DOOR SCHEDULE DETAILS DETAILS DETAILS /SPECIFICATIONS AUDIO /VISUAL OUTLET PLAN MECHANICAL PLAN, SCHEDULE & NOTES PARTIAL PLUMBING PLAN, WASTE & WATER RISER DIAGRAMS, TITUS AIR DISTRIBUTION DEVICES. DETAILS & NOTES SPECIFICATIONS LIGHTING PLAN, AUDIO SYSTEM SYMBOLS MASTER LIGHTING SWITCH BANK & NOTES ELECTRICAL PLAN & NOTES ELECTRICAL RISER DIAGRAMS, ELECTRICAL LOAD SUMMARY & ELECTRICAL PANELS. LIGHTING FIXTURE SCHEDULE SPECIFICATIONS PROJECT DATA PROJECT: METROPARK DESCRIPTION: RETAIL TENANT IMPROVEMENT LOCATION: SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188-2888 PH (206) 246 -0423 OWNER TENANT: METROPARK 532 CORAL RIDGE PLACE CITY OF INDUSTRY, CA 91746 PH (626) 968 -1419 CONTACT: GERARD GASTELUM STEVE RUNYON BUILDING DEPARTMENT: BUILDING DIVISION 6300 SOUTHCENTER BLVD #100 TUKWILA, WA 98188 PH (206) 431 -3670 WATER & SEWER: 600 MINKLER BLVD. TUKWILA, WA 98188 PH (206) 433 -1863 PH (206) 433 -1864 LANDLORD CORPORATE OFFICE: WESTFIELD CORPORATION INC. 11601 WILSHIRE BLVD, SUITE 1100 LOS ANGELES, CA 90025 CONTACT: JOSHUA KIMMEL PH (310) 893 -4761 FX (310) 575 -5991 CONTACT: SOLEY BURNHAM PH (310) 575 -5959 LANDLORD MALL OFFICE: SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 PH (206) 246 -0423 PHONE: QWEST BUSINESS CUSTOMERS 1- 800 - 603 -6000 EXIT REQUIREMENTS: TWO (2) EXIT REQ. TWO (2) EXITS PROVIDED CONSTRUCTION TYPE: TYPE IIB UNPROTECTED- - NONCOMBUSTIBLE OCUPANCY: M- MERCANTILE GROSS LEASE PREMISES: 2843 ± SQ. FT. OCCUPANCY LOAD: TOTAL NUMBER OF OCCUPANTS: 75 SALES AREA: X1914 = 30= 64 LOUNGE: ±202 _ 30= 7 FITTING ROOMS: +83 _ 30= 3 STOCK ROOM + HALLWAY 294 300= TENANT'S ARCHITECT: EXIT ILLUMINATION: EMERGENCY LIGHT SHALL BE PROVIDED AS SHOWN ON ELECTRICAL SHEETS. DRV DESIGN 16466 BERNARDO CTR DR. #136 SAN DIEGO CA 92128 PH (858) 592 -9205 FAX (858) 592 -8829 CONTACT: DEEPAK R. VORA STATE OF WASHINGTON REGISTERED ARCHITECT 7120 GAS & ELECTRIC : PUGET SOUND ENERGY 10885 NE 4th ST P.O. BOX 97034 BELLEVUE, WA 98009 -9734 PH 1- 888 - 225 -5775 (WITHIN WA.) PH (425) 452 -1234 (OUTSIDE WA.) FIRE: 444 ANDOVER PARK EAST TUKWILA, WA 98188 PH (206) 575 -4404 tukfdadm @ci.tukwila.wa.us GOVERNING CODE: ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, THE REQUIREMENTS P T -E FOLLOWING: AND ANY OTHER STATE AND LOCAL CODES HAVING JURISDICTION. Rzk.o.,.` '=0 BUILDING: 2006 IBC WITH WASHINGTON STATE AMENDMENTS C 1TY a- MECHANICAL: 2006 IMC WITH WASHINGTON STATE AMENDMENTS tOV 0 / ?L' / PLUMBING: 2006 UPC WITH WASHINGTON STATE AMENDMENTS ELECTRICAL: 2005 NEC WITH WASHINGTON STATE AMENDMENTS CLi I La HANDICAP: CHAPTER 11 IBC AND OTHER INTERNATIONAL BUILDING CODE REQUIREMENTS FOR BARRIER -FREE DESIGN ACCESS INCLUDING ICC /ANSI A117.1 -2003 FIRE: 2006 IFC WITH WASHINGTON STATE AMENDMENTS ENERGY: 2006 WASHINGTON NON RESIDENTIAL ENERGY CODE 219 MISCELLANEOUS NOTES: TENANT'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL REPORT ALL DISCREPCIES TO TENANT'S ARCHITECT. TENANTS GENERAL CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE, ETC. AS SET FORTH BY THE LANDLORD. FIRE SPRINKLERS: AN AUTOMATIC FIRE SPRINKLER SYSTEM IS EXISTING WITHIN THIS SPACE. THE CONTRACTOR SHALL REWORK AND MODIFY FOR NEW ROOM LAYOUT AND CEILING HEIGHTS IN CONFORMANCE WITH N.F.P.A 13 STANDARDS AND LOCAL CODES & REGULATIONS. ALL WORK SHALL BE DONE BY QUALIFIED SPRINKLER CONTRACTOR WHO SHALL DESIGN AND PREPARE SHOP DRAWINGS AND SUBMIT THEM TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SPRINKLER CONTRACTOR SHALL BE LANDLORD APPROVED. HEADS IN CEILING TILES TO BE CENTERED IN TILES WHEN IN A PUBLIC AREA. DATE: 09.20.07 SCALE: N.T.S. DRAWN: JOB: MP_SOCM SHEET T.1 OF SHEETS BY RESPONSIBILITY cont. RESPONSIBILITY SCHEDULE REVISIONS BY ITEM . NOT USE REMARKS ITEM EXISTING REMARKS ONIISIX3 OWNER OWNER OWNER OWNER GENERAL REQUIREMENTS ELECTRICAL 1. PERMITS AND FEES 1. STUB INTO SPACE SEE "E" SHEETS SPACE #1525 LEVEL 1 .� SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 2. TEMPORARY HEAT 2. METER SEE "E" SHEETS 3. TEMPORARY ELECTRIC 3. PANELS SEE "E" SHEETS 4. BARRICADE PROVIDE AS REQUIRED PER LANDLORD DIRECTION 4. TRANSFORMER • SEE "E" SHEETS 5. CLEAN -UP i 0 5. LIGHT FIXTURES AND LAMPS • 0 SEE "E" SHEETS SPACE WORK 6. TELEPHONE WIRING ! 0 SEE "E" SHEETS 1. DEMOLITION 7. COMMUNICATION • • SEE "E" SHEETS 2. SAW CUT SLAB /CORE DRILL AS REQUIRED AT CASHWRAP, TOILET ROOMS AND FIXTURES MECHANICAL CONCRETE SLAB 1. H VAC 1. CONCRETE SLAB (3000 PSI) 0 EXISTING A. VAV BOX • 0 SEE "MP" SHEETS 2. POUR CONCRETE (3000 PSI) A N/A B. DUCTWORK • SEE "MP" SHEETS STOREFRONT C. DIFFUSERS SEE "MP" SHEETS 1. GLAZING SEE STOREFRONT PLAN AND DETAILS 2. ROOF PENETRATIONS SEE "MP" SHEETS 2. ROLLING GRILLE N/A 3. SPRINKLER SYSTEM i' 0 i MODIFY AS NECESSARY 3. STOREFRONT DOORS • SEE STOREFRONT PLAN AND DETAILS 176 01,....... ....... 221 1 4. DOOR PULLS • 0 SEE STOREFRONT PLAN AND DETAILS 5. EXTERIOR WOOD SEE STOREFRONT PLAN AND DETAILS 6. EIFS, STUCCO, DRYVIT N/A 7. CAULKING SEE PLAN AND DETAILS 8. NEUTRAL PIERS • • LANDLORD PROVIDED CARPENTARY 1. METAL STUDS A. DEMISING WALLS • • • SEE FLOOR PLAN B. INTERIOR PARTITIONS SEE FLOOR PLAN C. FURRING • SEE FLOOR PLAN D. BLOCKING � SEE FLOOR PLAN 2. FRAMING FOR HVAC SEE HVAC PLAN 3. STANDARDS AND HARDWARE 0 SEE PLAN AND DETAILS DOORS 1. STOCKROOM DOOR /HARDWARE 0 e SEE DOOR SCHEDULE AND FLOOR PLAN 2. TOILET ROOM DOORS /HARDWARE • • SEE DOOR SCHEDULE AND FLOOR PLAN 3. SERVICE DOOR /HARDWARE • • SEE DOOR SCHEDULE AND FLOOR PLAN 4. FITTING ROOM DOORS /HARDWARE 0 x SEE DOOR SCHEDULE FLOOR PLAN & FIXTURE PLAN n FINISHES 1. GYPSUM BOARD • 0 PLANS; G.C. TO EXTEND GYP. BD. TO DECK IF REQUIRED RENEWED FOR CODE COMPLIANCE 2. TAPING AND SPACKLING AT NEW WALLS ONLY, SEE PLANS AND NOTES 3. FLOORS 4 99 APPROVED A. REQUIRED LEVELING ® SEE FINISH SCHEDULE 8c FLOOR PLAN I NOV ; (i 2007 ' B. WOOD FLOORING C. CARPET ® N/A lb SEE FINISH SCHEDULE & FLOOR PLAN City of Tukwila " B ILDING Q IVIS1 y RFr C'%T Y OF TL ;; < "1a NOV 0 / ?Uu! FL.;,siai i c.. I; i E. D. ENTRANCE MAT • N/A E. VINYL FLOOR • • SEE FINISH SCHEDULE & FLOOR PLAN F. FLOOR TILE • N/A G. TRANSITION STRIPS • SEE FINISH SCHEDULE & FLOOR PLAN H. MALL MATCH . SEE FINISH SCHEDULE & FLOOR PLAN 4. WALLS A. PAINT • 0 SEE FINISH SCHEDULE FINISH PLAN & ELEVATIONS B. WALL COVERING 0 • SEE FINISH SCHEDULE FINISH PLAN & ELEVATIONS C. FRP . SEE TOILET DETAIL 5. BASE A. WOOD ® , SEE FINISH SCHEDULE FINISH PLAN & ELEVATIONS B. VINYL 0 _ e SEE FINISH SCHEDULE FINISH PLAN & ELEVATIONS C. METAL SEE FINISH SCHEDULE FINISH PLAN & ELEVATIONS D. TILE . SEE STOREFRONT ELEVATION, SECTIONS & FINISH PLAN 6. CEILING A. GYP. BD. 41, 0 SEE REFLECTED CEILING PLANS AND NOTES B. LAY-IN TILE PLUMBING 0 0 SEE REFLECTED CEILING PLANS AND NOTES 1. TOILET ROOM FIXTURES /ACCS. a SEE MP SHEETS 2. UNDERSLAB ROUGH -IN 0 e SEE MP SHEETS 3. FINAL CONNECTIONS & VENTS • 0 SEE MP SHEETS EQUIPMENT 1. STOREFRONT SIGNS • _ CONTRACTOR TO COORDINATE WITH SIGN VENDOR 2. FIRE EXTINGUISHER (2A, 10BC TYPE PORTABLE) • 0 QUANTITY AND LOCATION PER FIRE MARSHALL 3. SOUND & SECURITY SYSTEM 0 ® ALL REQUIRED CONDUIT BY G.C, SEE AUDIO VISUAL A11. 4. FIRE ALARM SMOKE EVAC 0 0 IF REQUIRED FURNISHING 1. NEW STORE FIXTURES (WALL & FLOOR) 0 0 SEE FIXTURE PLAN AND SCHEDULE 2. STOCK SHELVING SYSTEM 3. MIRRORS & FRAMES 0 0 COORDINATE PURCHASE WITH VENDOR SEE FIXTURE PLAN AND SCHEDULE 4. STANDARDS HARDWARE 0 0 SEE FIXTURE PLAN AND SCHEDULE O PROPOSED ENTRANC= SIGN AGE PROPOSED ENTRANCE SIGN AGE SETBACK LIN PROPERTY LI PROPOSED WAYEINDING SIGNAGE PROPOSED RCYCLING AR PROPOSED WAYEINDING SIGNAGE PROPOSED ENTRANCE SIGNAGE METROPARK #1525 SIGN INTER WAYEINDING SIGNAGE PROPOSED PARKING STRUCTURE 227,972 SF 584 SPACES LIZED ECTION NORDSTROM 3 LEVELS 5IR OT .A P a4 ISTI STR REM G Pf PING IN / XIS NG ARK G ST IPIN TO RE AI N AS I RKIt' TO S IS rr�� qiiii r ■rr M 111111 IQ 1111 . •:III 1 " I 11 tak ISTING PARKING E E El E lE ❑ ZI 6 6 IO o W EJ E© 6 6 6 6 a O 6 A Finn■ ■.v 6 6 6 6 A (E) OLIVE GARDEN STRANDER BOULEVARD IGNALI TERSE FUTURE PAD SEE NOTE 1 t 111111: gr. 11P , POST OFFICE FIRESTONE JCPENNEY T.B.A. LEASE PARCEL 1.02 ACRES 38 CARS IZED RSECTIO SIGNALIZED INTERSECTI FUTURE PAD SEE NOTE 1 3 LEVELS ENTRANCE S GNAGE XISTING PARKING STRIPING TO 111 ONG SIGNALIZED INTERSECTION ENTRANCE 1 � SIGNALIZED INTERSECTION PAR KWA Y SIGNALIZED INTERSECTION PROPOSED ENTRANCE SI GN AGE ZZ m° (Am De uJ u li (J O SIGNALIZED INTERSECTION LJ 0 19 ACK LINE ERTY LINE PROPOSED WAYEINDING SIGNAGE REVIEWED FO CODE COMPLIANCE APPROVED NOV :s () 2007 City Of Tukwila EN TR AN_T I:_ DING DIVISION SIGNAGE PROPOSED RCYCLING AREA PROPOSED POLICE/ COMMUNITY ROOM PROPOSED FIRE CONTROL ROM NUMBER 147 EXISTING MALL PROPOSED MALL EXPANSION 395,157 SE PROPOSED ENTRANCE SIGN AGE A3.1 -50 PROPOSED WAYFINDING SIGNAGE PROPOSED PARKING STRUCTURE "B" 229,476 SE 546 SPACES PROPOSED WAYEINDING SIGNAGE PROPOSED L . S. POSPT�,ROFFII CE 0.6 ACRE C E 25 CApA.S,, _ 1:1 E 4 JY C:, NOV 0 f 2E7 PROPOSED BANK LEASE PARCEL 0.49 ACRE 22 CARS NORTH • WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile .310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE. IS THE PROPERTY OF NE ARCHITECT AND MAY NOT BE REPRCIXRCEO WITHOUT THE ARCHITECTS PERMSSICN AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME. ALL DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PRO,ECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT MUM PERMISSION FROM THE ARCHITECT Registration No. Consultants Approvals /Phase: PERMIT /BID ADDENDUM J 02/05/2007 Key Plan: No. Revision Date PLAN CHECK REVISIONS 2006 AUGUST 21 A REVISION '1' 2006 Sept. 26 A ADDENDUM J 2007 Feb. 5 A A A A A A A A A A A A A A A A A A Sheet Title PROPOSED SITE PLAN Job No. its 633 Southcenter Parkway Tukwllo, WA., 98188 206 -246 -042.3 Date 6-07-05 R.1 Scale r-80 O SENSIBLE HEAT GAIN PEOPLE VENTILATION ROOF LOAD LTS- SURFACE LTS - RECESSED MISC LOAD WALL LOAD SENSIBLE HEAT GAIN VENTILATION ROOF LOAD WALL LOAD COOLING OA DB 85 COOLING IA DB 75 HEATING OA 23 ROOF U- FACTOR 0.000 LIGHT DIVERS ** 1.3 VAV MIN AIR 500 LTS - SURFACE 5622 %LTS - SURFACE 83 WALL AREA 0 %ROOF TO SPACE 0 PEOPLE SENS HEAT 250 TOTAL SENSIBLE 58333 TOTAL COOLING LOAD SENS/TOTAL RATIO NOMINAL CFM (15 DEG F DIFF) SUPPLY AIR TEMP TEMPERATURE DIFFERENCE 0 0 0 TOTAL SENSIBLE 0 metropark Southcenter Mall Tukwila,WA 2843 SQUARE FEET ASHRAE DESIGN CONDITIONS COOLING LOAD SUMMARY HEATING LOAD SUMMARY 65914 BTUH 88 3119 CFM 58 DEG F 17 DEG F COOLING OA WB COOLING IA WB HEATING IA LTS- RECESSED %LTS- RECESSED MISC. WATTS SQ FT/PERSON NO OF PEOPLE WALL U- FACTOR PEOPLE LATENT LATENT HEAT GAIN 9477 PEOPLE 0 VENTILATION 0 0% TO SPACE 20704 83% TO SPACE 849 17% TO SPACE 27304 0 TOTAL LATENT LATENT HEAT GAIN VENTILATION TOTAL LATENT TOTAL HEATING LOAD NOMINAL KW ELEC HEAT MINIMUM KW ELEC HEAT (BASED ON 20 DEG F RISE @ VAV MIN AIR) 12:00:00 AM CNTYVAV.WKS * SA TEMP AT UNIT AT SPACE ON DESIGN DAY ** SPECIAL ALLOWANCE FACTOR PER ASHRAE (TABLE 15 /CHAPTER 26) DESIGN BASED ON LANDLORD PROVIDING MORN WARMUP. ING 65 + 63 68 1125+ 2.4W /SQFT 17+ 8000 + 75 + 38 0.20 + 200 7581 0 7581 0 BTUH 0 KW 3 KW 0 0 - 518 SQ FT/TON 1.10 CFM /SQ FT 23 BTUH /SQ FT 5.5 TONS MECHANICAL PLAN CODED NOTES: 0 THERMOSTAT MOUNTED AT 48" A.F.E. COORDINATE EXACT LOCATION WITH TENANT. VERIFY ANY NEW REQUIREMENTS WITH MALL MANAGEMENT. 2 CONTRACTOR TO PROVIDE AND INSTALL EXHAUST 2 FAN. FAN SHALL BE 100 CFM. INTERLOCK WITH TOILET ROOM LIGHTING. SEE LIGHT FIXTURE SCHEDULE ON SHEET M2 FOR MANUFACTURER & MODEL NUMBER. PROVIDE 10" EXH. DUCT TO EXISTING L.L. EXHAUST DUCT V.I.F. PROVIDE BACKDRAFT DAMPER. 30 T.G.C. SHALL INSTALL VAV -1 PER L.L. DIRECTION. LANDLORD NOTES: LANDLORD HAS PROVIDED A PROPRIETARY D.D.C. CONTROL SYSTEM FOR V.A.V. CONTROL—TENANT TO PROVIDE i" CONDUIT AND SHIELDED CABLE FROM LANDLORD'S JUNCTION BOX TO V.A.V. BOX(ES) AND THERMOSTAT(S) —FINAL WIRING CONNECTIONS TO ALL DEVICES BY LANDLORD AT TENANT'S EXPENSE —ALL AS PER PROJECT STANDARD DETAILS. T.G.C. SHALL ENGAGE A SEPERATE TEMPERATURE CONTROL CONTRACTOR FOR FINAL SET —UP OF SYSTEM(S) OPERATIONS AND AIR BALANCING. GIVE ONE COPY OF BALANCE REPORT TO LANDLORD'S BUILDING ENGINEER. T.G.C. MUST USE LANDLORD APPROVED CONTRACTOR SET VAV BOX TO DELIVER 3,325 CFM MAX. MECHANICAL GENERAL NOTES: 1. ALL DUCTWORK, HANGERS, DAMPER CONSTRUCTION, SEAMS, INSTALLATION, ETC., SHALL CONFORM TO THE STANDARDS AS ADOPTED BY A.S.H.R.A.E. AND SMACNA. ALL WORK SHALL CONFORM TO ALL APPLICABLE LAWS, RULES AND REGULATIONS AND RECOMMENDATIONS OF LOCAL BUILDING DEPARTMENT, NATIONAL BOARD OF FIRE UNDERWRITERS, N.F.P.A., AND SHOPPING CENTER GENERAL SPECIFICATIONS_ ALL DUCTWORK SHALL BE SHEETMETAL CONFORMING TO SMACNA STANDARDS FOR LOW PRESSURE DUCTWORK AND A.S.H.R.A.E. STANDARD 90-75. 2. EXAMINATION: BIDDER, BEFORE SUBMITTING A PROPOSAL SHALL EXAMINE THE SITE, DRAWINGS AND SPECIFICATIONS, INFORM HIMSELF AS TO THE STATE AND LOCAL CODES AND LAWS HAVING JURISDICTION AND ALLOW FOR LICENSES AND FEES TO BE PAID AS DIRECTED OR REQUIRED TO COMPLETE THE WORK UNDER THE SCOPE OF THIS CONTRACT. 3. THE MECHANICAL CONTRACTOR SHOULD FURNISH, CONNECT AND INSTALL THE THERMOSTAT /CONTROL WIRING AND THE ELECTRICAL CONTRACTOR SHOULD PROVIDE, INSTALL AND CONNECT THE ELECTRIC TO THE UNITS. 4. SCHEDULE OF WORK: THIS CONTRACTOR SHALL BE REQUIRED TO FAMILIARIZE HIMSELF WITH THE PROPOSED WORK SCHEDULE AND SHALL COORDINATE HIS WORK SCHEDULE WITH THE OTHER TRADES, SO THAT WORK PROGRESSES CAN BE PLANNED IN A PROPER SYSTEMATIC FASHION TO AVOID ANY DUPLICATION OF EFFORT AND RESULTANT DELAY OF PROJECT. 5. CUTTING AND PATCHING: THIS CONTRACTOR MUST LAY OUT HIS WORK IN ADVANCE OF NEW CONSTRUCTION IN ORDER THAT UNNECESSARY CUTTING AND PATCHING WILL BE AVOIDED. OPENINGS SHALL BE REUSED AS SHOWN AND ANY MODIFICATIONS TO ROOF OPENINGS SHALL BE APPROVED BY THE LANDLORD, DONE BY THE LANDLORD'S ROOFING CONTRACTOR AND PAID FOR BY THE TENANT. 6. FLEXIBLE DUCTWORK: FOR CONNECTIONS BETWEEN RIGID DUCTWORK INSTALL FLAT METAL SPIRAL MECHANICALLY LOCKED FABRIC COMPONENTS, CAPABLE OF BEING SHAPED FOR CONNECTION TO EITHER ROUND OR OVAL BOOT CONNECTIONS. ALL CONNECTIONS SHALL BE MADE AIR TIGHT BY MEANS OF CLAMPS OR INDUSTRIAL CEMENT #330 AND WRAPPED WITH DUCT TAPE. LENGTH OF FLEXIBLE DUCT TO BE MAXIMUM OF 5'. STEEL SPIRAL TO BE ELECTROGALVANIZED FABRIC TO BE NEOPRENE COATED, WITH FABRIC CAPABLE OF MEETING N.F.P.A. 90A AND UL 181 FOR CLASS 1 CONNECTORS. MANUFACTURER: WIREMOLD AIR DUCT TYPE 57. EXISTING MAIN SUPPLY AIR TRUNK INSTALL 16" DIA. INSULATED MED. PRESSURE METAL SPIRAL DUCTWORK 5 FEET LONG STRAIGHT FROM TAP TO VAV BOX. PROVIDE A 30 "X24" RETURN AIR OPENING THRU WALL AS HIGH AS POSSIBLE WITH UPSIDE DOWN LOUVER EXIST'G. MALL TOILET EXHAUST DUCT FOR TENANT CONNECTION. V.I.F. 7. DUCTWORK SHALL BE FABRICATED OF GALVANIZED SHEET METAL PER AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS' STANDARDS AS OUTLINED FOR "AIR DUCT DESIGN" IN THE LATEST EDITION OF THE "ASHRAE FUNDAMENTALS" AND AS REQUIRED BY THE CONSTRUCTION DETAILS OUTLINED IN THE APPLICABLE SMACNA STANDARDS. 8. SUPPLY DUCTWORK INSIDE BUILDING SHALL BE INSULATED WITH 1" ALUMINUM FOIL FACED FIBERGLASS BLANKET OVERLAPPED AND WIRED ON AND ALL DUCTWORK SHALL BE INSTALLED IN CONCEALED SPACE ABOVE CEILINGS. 9. PROVIDE CLEAR ACCESS TO ALL EQUIPMENT WITHIN THE LEASED SPACE. 10. CONTRACTOR SHALL PROVIDE OPERABLE H AND V SYSTEMS COMPLETE IN ALL RESPECTS AS CONTEMPLATED BY THE INFORMATION INDICATED ON THE DRAWINGS. IT IS NOT INTENDED THAT THE DRAWINGS AND SPECIFICATIONS INDICATE EACH AND EVERY ITEM OF INFORMATION NECESSARY FOR COMPLETE SYSTEMS BUT INDICATE SUFFICIENT INFORMATION FOR THE CONTRACTOR TO SECURE ADDITIONAL INFORMATION FROM OTHER SOURCES AND PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR NECESSARY FOR COMPLETE INSTALLATIONS. 11. ALL LABOR, MATERIALS AND EQUIPMENT SHALL BE PROVIDED WITH ONE YEAR GUARANTEE FROM DEFECTS. 12. PROVIDE ARCHITECT WITH THREE (3) COPIES OF AIR BALANCE REPORT. INSTRUCT OWNER IN USE OF EQUIPMENT. AIR BALANCE REPORT TO BE AN INDEPENDENT TESTING AGENCY. AIR BALANCE TEST REPORT TO BE TAKEN IN THE LATE AFTERNOON WITH THE FOLLOWING TEMPERATURE READINGS DOCUMENTED (IN ADDITION TO CFM) 1.) TEMPERATURE OF AIR LEAVING EACH CEILING DIFFUSER, 2.) TEMPERATURE OF AIR LEAVING HVAC UNIT, 3.) TEMPERATURE OF OUTSIDE AIR AT HVAC UNIT, 4.) TEMPERATURE OF AIR WITHIN SALES AREA (AT THERMOSTAT). 13. T.G.C. TO REPLACE FILTERS PRIOR TO TURNOVER. 14 DEMOLITION: REMOVE ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PLUMBING FIXTURES, PIPING SYSTEMS, ETC...NOT BEING REUSED. DO NOT JUST ABANDON. r CO\ TRACTOR \OTHS: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT, LANDLORD OR TENANT OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BY STATE AND LOCAL CODES WHETHER INDICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AND COMPLIANCE WITH GOVERNING CODES / REQUIREMENTS HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN, HAD AN EXAMINATION AND CODE REVIEW BEEN MADE, WILL NOT BE ALLOWED. MECHANICAL PLAN PROVIDE A 24 "X24" RETURN AIR OPENING I THRU WALL ABOVE CEILING AS HIGH AS POSSIBLE COVER OPENING WITH 1"X1" WELDED WIRE SCREEN. City Of Tukwila I$ I DING DIVISION._ 1 1 01 EXIST'G. 16" DIA. TAP FOR TENANT CONNECTION PROVIDE SPLITTER DAMPER WITH 65/35 SPLIT. PROVIDE A 24 "X24" RETURN AIR OPENING THRU WALL ABOVE CEILING AS HIGH AS POSSIBLE COVER OPENING WITH 1 "X1" WELDED WIRE SCREEN. I .. no.otirtzu NOV 3 rI 2007 NOY 0 i2007 DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817- 251 --8411 Q CO CQ r N Q Q Ln -› 0_ 00 L� Ln s-- J > zQ Q U LJ I- 114 U ° j f) CD REVISIONS SHEET DRAWN: TS DATE: 09.20.07 SCALE: 1/4 "4-17 JOB: MP SOCM M.1 OF 3 E- SHEETS BY 0) N CO co N 0] Ln co LL E 0 LC) 0 O � N N O]- c d v I I , V, A, C. LEGE\ D SYMBOL DESCRIPTION V E\ T SCI DUCTWORK MARK / VAV -1 FAN POWERED VARIABLE AIR VOLUME CONTROL TITUS ATQS -16" DEVICE SET SIZE 16, 500 CFM MINIMUM AIRFLOW, SET AIRFLOW AT 3325 CFM. VAV DEVICE SET, COMPLETE WITH ELECTRONIC CONTROLS AND ZONE SENSOR (T —STAT) PROVIDED AND INSTALLED BY T.G.C. VERIFY ALL REQUIREMENTS WITH LANDLORD. Q4 THERMOSTAT (100) DENOTES CFM QUANTITY )2. CEILING DIFFUSER 0 DUCT MOUNTED DIFFUSER \ CEILING RETURN REGISTER L— VOLUME DAMPER -d- 1" UNDERCUT DOOR SD DUCT SMOKE DETECTOR AL 1" ACOUSTICAL LINING CFM CUBIC FEET OF AIR PER MINUTE EF EXHAUST FAN NK NECK CO E E ®R ®Anea,wee SENSIBLE HEAT GAIN PEOPLE VENTILATION ROOF LOAD LTS- SURFACE LTS - RECESSED MISC LOAD WALL LOAD SENSIBLE HEAT GAIN VENTILATION ROOF LOAD WALL LOAD COOLING OA DB 85 COOLING IA DB 75 HEATING OA 23 ROOF U- FACTOR 0.000 LIGHT DIVERS ** 1.3 VAV MIN AIR 500 LTS - SURFACE 5622 %LTS - SURFACE 83 WALL AREA 0 %ROOF TO SPACE 0 PEOPLE SENS HEAT 250 TOTAL SENSIBLE 58333 TOTAL COOLING LOAD SENS/TOTAL RATIO NOMINAL CFM (15 DEG F DIFF) SUPPLY AIR TEMP TEMPERATURE DIFFERENCE 0 0 0 TOTAL SENSIBLE 0 metropark Southcenter Mall Tukwila,WA 2843 SQUARE FEET ASHRAE DESIGN CONDITIONS COOLING LOAD SUMMARY HEATING LOAD SUMMARY 65914 BTUH 88 3119 CFM 58 DEG F 17 DEG F COOLING OA WB COOLING IA WB HEATING IA LTS- RECESSED %LTS- RECESSED MISC. WATTS SQ FT/PERSON NO OF PEOPLE WALL U- FACTOR PEOPLE LATENT LATENT HEAT GAIN 9477 PEOPLE 0 VENTILATION 0 0% TO SPACE 20704 83% TO SPACE 849 17% TO SPACE 27304 0 TOTAL LATENT LATENT HEAT GAIN VENTILATION TOTAL LATENT TOTAL HEATING LOAD NOMINAL KW ELEC HEAT MINIMUM KW ELEC HEAT (BASED ON 20 DEG F RISE @ VAV MIN AIR) 12:00:00 AM CNTYVAV.WKS * SA TEMP AT UNIT AT SPACE ON DESIGN DAY ** SPECIAL ALLOWANCE FACTOR PER ASHRAE (TABLE 15 /CHAPTER 26) DESIGN BASED ON LANDLORD PROVIDING MORN WARMUP. ING 65 + 63 68 1125+ 2.4W /SQFT 17+ 8000 + 75 + 38 0.20 + 200 7581 0 7581 0 BTUH 0 KW 3 KW 0 0 - 518 SQ FT/TON 1.10 CFM /SQ FT 23 BTUH /SQ FT 5.5 TONS MECHANICAL PLAN CODED NOTES: 0 THERMOSTAT MOUNTED AT 48" A.F.E. COORDINATE EXACT LOCATION WITH TENANT. VERIFY ANY NEW REQUIREMENTS WITH MALL MANAGEMENT. 2 CONTRACTOR TO PROVIDE AND INSTALL EXHAUST 2 FAN. FAN SHALL BE 100 CFM. INTERLOCK WITH TOILET ROOM LIGHTING. SEE LIGHT FIXTURE SCHEDULE ON SHEET M2 FOR MANUFACTURER & MODEL NUMBER. PROVIDE 10" EXH. DUCT TO EXISTING L.L. EXHAUST DUCT V.I.F. PROVIDE BACKDRAFT DAMPER. 30 T.G.C. SHALL INSTALL VAV -1 PER L.L. DIRECTION. LANDLORD NOTES: LANDLORD HAS PROVIDED A PROPRIETARY D.D.C. CONTROL SYSTEM FOR V.A.V. CONTROL—TENANT TO PROVIDE i" CONDUIT AND SHIELDED CABLE FROM LANDLORD'S JUNCTION BOX TO V.A.V. BOX(ES) AND THERMOSTAT(S) —FINAL WIRING CONNECTIONS TO ALL DEVICES BY LANDLORD AT TENANT'S EXPENSE —ALL AS PER PROJECT STANDARD DETAILS. T.G.C. SHALL ENGAGE A SEPERATE TEMPERATURE CONTROL CONTRACTOR FOR FINAL SET —UP OF SYSTEM(S) OPERATIONS AND AIR BALANCING. GIVE ONE COPY OF BALANCE REPORT TO LANDLORD'S BUILDING ENGINEER. T.G.C. MUST USE LANDLORD APPROVED CONTRACTOR SET VAV BOX TO DELIVER 3,325 CFM MAX. MECHANICAL GENERAL NOTES: 1. ALL DUCTWORK, HANGERS, DAMPER CONSTRUCTION, SEAMS, INSTALLATION, ETC., SHALL CONFORM TO THE STANDARDS AS ADOPTED BY A.S.H.R.A.E. AND SMACNA. ALL WORK SHALL CONFORM TO ALL APPLICABLE LAWS, RULES AND REGULATIONS AND RECOMMENDATIONS OF LOCAL BUILDING DEPARTMENT, NATIONAL BOARD OF FIRE UNDERWRITERS, N.F.P.A., AND SHOPPING CENTER GENERAL SPECIFICATIONS_ ALL DUCTWORK SHALL BE SHEETMETAL CONFORMING TO SMACNA STANDARDS FOR LOW PRESSURE DUCTWORK AND A.S.H.R.A.E. STANDARD 90-75. 2. EXAMINATION: BIDDER, BEFORE SUBMITTING A PROPOSAL SHALL EXAMINE THE SITE, DRAWINGS AND SPECIFICATIONS, INFORM HIMSELF AS TO THE STATE AND LOCAL CODES AND LAWS HAVING JURISDICTION AND ALLOW FOR LICENSES AND FEES TO BE PAID AS DIRECTED OR REQUIRED TO COMPLETE THE WORK UNDER THE SCOPE OF THIS CONTRACT. 3. THE MECHANICAL CONTRACTOR SHOULD FURNISH, CONNECT AND INSTALL THE THERMOSTAT /CONTROL WIRING AND THE ELECTRICAL CONTRACTOR SHOULD PROVIDE, INSTALL AND CONNECT THE ELECTRIC TO THE UNITS. 4. SCHEDULE OF WORK: THIS CONTRACTOR SHALL BE REQUIRED TO FAMILIARIZE HIMSELF WITH THE PROPOSED WORK SCHEDULE AND SHALL COORDINATE HIS WORK SCHEDULE WITH THE OTHER TRADES, SO THAT WORK PROGRESSES CAN BE PLANNED IN A PROPER SYSTEMATIC FASHION TO AVOID ANY DUPLICATION OF EFFORT AND RESULTANT DELAY OF PROJECT. 5. CUTTING AND PATCHING: THIS CONTRACTOR MUST LAY OUT HIS WORK IN ADVANCE OF NEW CONSTRUCTION IN ORDER THAT UNNECESSARY CUTTING AND PATCHING WILL BE AVOIDED. OPENINGS SHALL BE REUSED AS SHOWN AND ANY MODIFICATIONS TO ROOF OPENINGS SHALL BE APPROVED BY THE LANDLORD, DONE BY THE LANDLORD'S ROOFING CONTRACTOR AND PAID FOR BY THE TENANT. 6. FLEXIBLE DUCTWORK: FOR CONNECTIONS BETWEEN RIGID DUCTWORK INSTALL FLAT METAL SPIRAL MECHANICALLY LOCKED FABRIC COMPONENTS, CAPABLE OF BEING SHAPED FOR CONNECTION TO EITHER ROUND OR OVAL BOOT CONNECTIONS. ALL CONNECTIONS SHALL BE MADE AIR TIGHT BY MEANS OF CLAMPS OR INDUSTRIAL CEMENT #330 AND WRAPPED WITH DUCT TAPE. LENGTH OF FLEXIBLE DUCT TO BE MAXIMUM OF 5'. STEEL SPIRAL TO BE ELECTROGALVANIZED FABRIC TO BE NEOPRENE COATED, WITH FABRIC CAPABLE OF MEETING N.F.P.A. 90A AND UL 181 FOR CLASS 1 CONNECTORS. MANUFACTURER: WIREMOLD AIR DUCT TYPE 57. EXISTING MAIN SUPPLY AIR TRUNK INSTALL 16" DIA. INSULATED MED. PRESSURE METAL SPIRAL DUCTWORK 5 FEET LONG STRAIGHT FROM TAP TO VAV BOX. PROVIDE A 30 "X24" RETURN AIR OPENING THRU WALL AS HIGH AS POSSIBLE WITH UPSIDE DOWN LOUVER EXIST'G. MALL TOILET EXHAUST DUCT FOR TENANT CONNECTION. V.I.F. 7. DUCTWORK SHALL BE FABRICATED OF GALVANIZED SHEET METAL PER AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS' STANDARDS AS OUTLINED FOR "AIR DUCT DESIGN" IN THE LATEST EDITION OF THE "ASHRAE FUNDAMENTALS" AND AS REQUIRED BY THE CONSTRUCTION DETAILS OUTLINED IN THE APPLICABLE SMACNA STANDARDS. 8. SUPPLY DUCTWORK INSIDE BUILDING SHALL BE INSULATED WITH 1" ALUMINUM FOIL FACED FIBERGLASS BLANKET OVERLAPPED AND WIRED ON AND ALL DUCTWORK SHALL BE INSTALLED IN CONCEALED SPACE ABOVE CEILINGS. 9. PROVIDE CLEAR ACCESS TO ALL EQUIPMENT WITHIN THE LEASED SPACE. 10. CONTRACTOR SHALL PROVIDE OPERABLE H AND V SYSTEMS COMPLETE IN ALL RESPECTS AS CONTEMPLATED BY THE INFORMATION INDICATED ON THE DRAWINGS. IT IS NOT INTENDED THAT THE DRAWINGS AND SPECIFICATIONS INDICATE EACH AND EVERY ITEM OF INFORMATION NECESSARY FOR COMPLETE SYSTEMS BUT INDICATE SUFFICIENT INFORMATION FOR THE CONTRACTOR TO SECURE ADDITIONAL INFORMATION FROM OTHER SOURCES AND PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR NECESSARY FOR COMPLETE INSTALLATIONS. 11. ALL LABOR, MATERIALS AND EQUIPMENT SHALL BE PROVIDED WITH ONE YEAR GUARANTEE FROM DEFECTS. 12. PROVIDE ARCHITECT WITH THREE (3) COPIES OF AIR BALANCE REPORT. INSTRUCT OWNER IN USE OF EQUIPMENT. AIR BALANCE REPORT TO BE AN INDEPENDENT TESTING AGENCY. AIR BALANCE TEST REPORT TO BE TAKEN IN THE LATE AFTERNOON WITH THE FOLLOWING TEMPERATURE READINGS DOCUMENTED (IN ADDITION TO CFM) 1.) TEMPERATURE OF AIR LEAVING EACH CEILING DIFFUSER, 2.) TEMPERATURE OF AIR LEAVING HVAC UNIT, 3.) TEMPERATURE OF OUTSIDE AIR AT HVAC UNIT, 4.) TEMPERATURE OF AIR WITHIN SALES AREA (AT THERMOSTAT). 13. T.G.C. TO REPLACE FILTERS PRIOR TO TURNOVER. 14 DEMOLITION: REMOVE ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PLUMBING FIXTURES, PIPING SYSTEMS, ETC...NOT BEING REUSED. DO NOT JUST ABANDON. r CO\ TRACTOR \OTHS: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT, LANDLORD OR TENANT OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BY STATE AND LOCAL CODES WHETHER INDICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AND COMPLIANCE WITH GOVERNING CODES / REQUIREMENTS HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN, HAD AN EXAMINATION AND CODE REVIEW BEEN MADE, WILL NOT BE ALLOWED. MECHANICAL PLAN PROVIDE A 24 "X24" RETURN AIR OPENING I THRU WALL ABOVE CEILING AS HIGH AS POSSIBLE COVER OPENING WITH 1"X1" WELDED WIRE SCREEN. City Of Tukwila I$ I DING DIVISION._ 1 1 01 EXIST'G. 16" DIA. TAP FOR TENANT CONNECTION PROVIDE SPLITTER DAMPER WITH 65/35 SPLIT. PROVIDE A 24 "X24" RETURN AIR OPENING THRU WALL ABOVE CEILING AS HIGH AS POSSIBLE COVER OPENING WITH 1 "X1" WELDED WIRE SCREEN. I .. no.otirtzu NOV 3 rI 2007 NOY 0 i2007 DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817- 251 --8411 Q CO CQ r N Q Q Ln -› 0_ 00 L� Ln s-- J > zQ Q U LJ I- 114 U ° j f) CD REVISIONS SHEET DRAWN: TS DATE: 09.20.07 SCALE: 1/4 "4-17 JOB: MP SOCM M.1 OF 3 E- SHEETS BY 0) N CO co N 0] Ln co LL E 0 LC) 0 O � N N O]- c d v EC- A\ CAL F QU P V E\ T SCI I H 3 J LI- - INSTALLED BY T.G.C. MARK DESCRIPTION VAV -1 FAN POWERED VARIABLE AIR VOLUME CONTROL TITUS ATQS -16" DEVICE SET SIZE 16, 500 CFM MINIMUM AIRFLOW, SET AIRFLOW AT 3325 CFM. VAV DEVICE SET, COMPLETE WITH ELECTRONIC CONTROLS AND ZONE SENSOR (T —STAT) PROVIDED AND INSTALLED BY T.G.C. VERIFY ALL REQUIREMENTS WITH LANDLORD. SENSIBLE HEAT GAIN PEOPLE VENTILATION ROOF LOAD LTS- SURFACE LTS - RECESSED MISC LOAD WALL LOAD SENSIBLE HEAT GAIN VENTILATION ROOF LOAD WALL LOAD COOLING OA DB 85 COOLING IA DB 75 HEATING OA 23 ROOF U- FACTOR 0.000 LIGHT DIVERS ** 1.3 VAV MIN AIR 500 LTS - SURFACE 5622 %LTS - SURFACE 83 WALL AREA 0 %ROOF TO SPACE 0 PEOPLE SENS HEAT 250 TOTAL SENSIBLE 58333 TOTAL COOLING LOAD SENS/TOTAL RATIO NOMINAL CFM (15 DEG F DIFF) SUPPLY AIR TEMP TEMPERATURE DIFFERENCE 0 0 0 TOTAL SENSIBLE 0 metropark Southcenter Mall Tukwila,WA 2843 SQUARE FEET ASHRAE DESIGN CONDITIONS COOLING LOAD SUMMARY HEATING LOAD SUMMARY 65914 BTUH 88 3119 CFM 58 DEG F 17 DEG F COOLING OA WB COOLING IA WB HEATING IA LTS- RECESSED %LTS- RECESSED MISC. WATTS SQ FT/PERSON NO OF PEOPLE WALL U- FACTOR PEOPLE LATENT LATENT HEAT GAIN 9477 PEOPLE 0 VENTILATION 0 0% TO SPACE 20704 83% TO SPACE 849 17% TO SPACE 27304 0 TOTAL LATENT LATENT HEAT GAIN VENTILATION TOTAL LATENT TOTAL HEATING LOAD NOMINAL KW ELEC HEAT MINIMUM KW ELEC HEAT (BASED ON 20 DEG F RISE @ VAV MIN AIR) 12:00:00 AM CNTYVAV.WKS * SA TEMP AT UNIT AT SPACE ON DESIGN DAY ** SPECIAL ALLOWANCE FACTOR PER ASHRAE (TABLE 15 /CHAPTER 26) DESIGN BASED ON LANDLORD PROVIDING MORN WARMUP. ING 65 + 63 68 1125+ 2.4W /SQFT 17+ 8000 + 75 + 38 0.20 + 200 7581 0 7581 0 BTUH 0 KW 3 KW 0 0 - 518 SQ FT/TON 1.10 CFM /SQ FT 23 BTUH /SQ FT 5.5 TONS MECHANICAL PLAN CODED NOTES: 0 THERMOSTAT MOUNTED AT 48" A.F.E. COORDINATE EXACT LOCATION WITH TENANT. VERIFY ANY NEW REQUIREMENTS WITH MALL MANAGEMENT. 2 CONTRACTOR TO PROVIDE AND INSTALL EXHAUST 2 FAN. FAN SHALL BE 100 CFM. INTERLOCK WITH TOILET ROOM LIGHTING. SEE LIGHT FIXTURE SCHEDULE ON SHEET M2 FOR MANUFACTURER & MODEL NUMBER. PROVIDE 10" EXH. DUCT TO EXISTING L.L. EXHAUST DUCT V.I.F. PROVIDE BACKDRAFT DAMPER. 30 T.G.C. SHALL INSTALL VAV -1 PER L.L. DIRECTION. LANDLORD NOTES: LANDLORD HAS PROVIDED A PROPRIETARY D.D.C. CONTROL SYSTEM FOR V.A.V. CONTROL—TENANT TO PROVIDE i" CONDUIT AND SHIELDED CABLE FROM LANDLORD'S JUNCTION BOX TO V.A.V. BOX(ES) AND THERMOSTAT(S) —FINAL WIRING CONNECTIONS TO ALL DEVICES BY LANDLORD AT TENANT'S EXPENSE —ALL AS PER PROJECT STANDARD DETAILS. T.G.C. SHALL ENGAGE A SEPERATE TEMPERATURE CONTROL CONTRACTOR FOR FINAL SET —UP OF SYSTEM(S) OPERATIONS AND AIR BALANCING. GIVE ONE COPY OF BALANCE REPORT TO LANDLORD'S BUILDING ENGINEER. T.G.C. MUST USE LANDLORD APPROVED CONTRACTOR SET VAV BOX TO DELIVER 3,325 CFM MAX. MECHANICAL GENERAL NOTES: 1. ALL DUCTWORK, HANGERS, DAMPER CONSTRUCTION, SEAMS, INSTALLATION, ETC., SHALL CONFORM TO THE STANDARDS AS ADOPTED BY A.S.H.R.A.E. AND SMACNA. ALL WORK SHALL CONFORM TO ALL APPLICABLE LAWS, RULES AND REGULATIONS AND RECOMMENDATIONS OF LOCAL BUILDING DEPARTMENT, NATIONAL BOARD OF FIRE UNDERWRITERS, N.F.P.A., AND SHOPPING CENTER GENERAL SPECIFICATIONS_ ALL DUCTWORK SHALL BE SHEETMETAL CONFORMING TO SMACNA STANDARDS FOR LOW PRESSURE DUCTWORK AND A.S.H.R.A.E. STANDARD 90-75. 2. EXAMINATION: BIDDER, BEFORE SUBMITTING A PROPOSAL SHALL EXAMINE THE SITE, DRAWINGS AND SPECIFICATIONS, INFORM HIMSELF AS TO THE STATE AND LOCAL CODES AND LAWS HAVING JURISDICTION AND ALLOW FOR LICENSES AND FEES TO BE PAID AS DIRECTED OR REQUIRED TO COMPLETE THE WORK UNDER THE SCOPE OF THIS CONTRACT. 3. THE MECHANICAL CONTRACTOR SHOULD FURNISH, CONNECT AND INSTALL THE THERMOSTAT /CONTROL WIRING AND THE ELECTRICAL CONTRACTOR SHOULD PROVIDE, INSTALL AND CONNECT THE ELECTRIC TO THE UNITS. 4. SCHEDULE OF WORK: THIS CONTRACTOR SHALL BE REQUIRED TO FAMILIARIZE HIMSELF WITH THE PROPOSED WORK SCHEDULE AND SHALL COORDINATE HIS WORK SCHEDULE WITH THE OTHER TRADES, SO THAT WORK PROGRESSES CAN BE PLANNED IN A PROPER SYSTEMATIC FASHION TO AVOID ANY DUPLICATION OF EFFORT AND RESULTANT DELAY OF PROJECT. 5. CUTTING AND PATCHING: THIS CONTRACTOR MUST LAY OUT HIS WORK IN ADVANCE OF NEW CONSTRUCTION IN ORDER THAT UNNECESSARY CUTTING AND PATCHING WILL BE AVOIDED. OPENINGS SHALL BE REUSED AS SHOWN AND ANY MODIFICATIONS TO ROOF OPENINGS SHALL BE APPROVED BY THE LANDLORD, DONE BY THE LANDLORD'S ROOFING CONTRACTOR AND PAID FOR BY THE TENANT. 6. FLEXIBLE DUCTWORK: FOR CONNECTIONS BETWEEN RIGID DUCTWORK INSTALL FLAT METAL SPIRAL MECHANICALLY LOCKED FABRIC COMPONENTS, CAPABLE OF BEING SHAPED FOR CONNECTION TO EITHER ROUND OR OVAL BOOT CONNECTIONS. ALL CONNECTIONS SHALL BE MADE AIR TIGHT BY MEANS OF CLAMPS OR INDUSTRIAL CEMENT #330 AND WRAPPED WITH DUCT TAPE. LENGTH OF FLEXIBLE DUCT TO BE MAXIMUM OF 5'. STEEL SPIRAL TO BE ELECTROGALVANIZED FABRIC TO BE NEOPRENE COATED, WITH FABRIC CAPABLE OF MEETING N.F.P.A. 90A AND UL 181 FOR CLASS 1 CONNECTORS. MANUFACTURER: WIREMOLD AIR DUCT TYPE 57. EXISTING MAIN SUPPLY AIR TRUNK INSTALL 16" DIA. INSULATED MED. PRESSURE METAL SPIRAL DUCTWORK 5 FEET LONG STRAIGHT FROM TAP TO VAV BOX. PROVIDE A 30 "X24" RETURN AIR OPENING THRU WALL AS HIGH AS POSSIBLE WITH UPSIDE DOWN LOUVER EXIST'G. MALL TOILET EXHAUST DUCT FOR TENANT CONNECTION. V.I.F. 7. DUCTWORK SHALL BE FABRICATED OF GALVANIZED SHEET METAL PER AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS' STANDARDS AS OUTLINED FOR "AIR DUCT DESIGN" IN THE LATEST EDITION OF THE "ASHRAE FUNDAMENTALS" AND AS REQUIRED BY THE CONSTRUCTION DETAILS OUTLINED IN THE APPLICABLE SMACNA STANDARDS. 8. SUPPLY DUCTWORK INSIDE BUILDING SHALL BE INSULATED WITH 1" ALUMINUM FOIL FACED FIBERGLASS BLANKET OVERLAPPED AND WIRED ON AND ALL DUCTWORK SHALL BE INSTALLED IN CONCEALED SPACE ABOVE CEILINGS. 9. PROVIDE CLEAR ACCESS TO ALL EQUIPMENT WITHIN THE LEASED SPACE. 10. CONTRACTOR SHALL PROVIDE OPERABLE H AND V SYSTEMS COMPLETE IN ALL RESPECTS AS CONTEMPLATED BY THE INFORMATION INDICATED ON THE DRAWINGS. IT IS NOT INTENDED THAT THE DRAWINGS AND SPECIFICATIONS INDICATE EACH AND EVERY ITEM OF INFORMATION NECESSARY FOR COMPLETE SYSTEMS BUT INDICATE SUFFICIENT INFORMATION FOR THE CONTRACTOR TO SECURE ADDITIONAL INFORMATION FROM OTHER SOURCES AND PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR NECESSARY FOR COMPLETE INSTALLATIONS. 11. ALL LABOR, MATERIALS AND EQUIPMENT SHALL BE PROVIDED WITH ONE YEAR GUARANTEE FROM DEFECTS. 12. PROVIDE ARCHITECT WITH THREE (3) COPIES OF AIR BALANCE REPORT. INSTRUCT OWNER IN USE OF EQUIPMENT. AIR BALANCE REPORT TO BE AN INDEPENDENT TESTING AGENCY. AIR BALANCE TEST REPORT TO BE TAKEN IN THE LATE AFTERNOON WITH THE FOLLOWING TEMPERATURE READINGS DOCUMENTED (IN ADDITION TO CFM) 1.) TEMPERATURE OF AIR LEAVING EACH CEILING DIFFUSER, 2.) TEMPERATURE OF AIR LEAVING HVAC UNIT, 3.) TEMPERATURE OF OUTSIDE AIR AT HVAC UNIT, 4.) TEMPERATURE OF AIR WITHIN SALES AREA (AT THERMOSTAT). 13. T.G.C. TO REPLACE FILTERS PRIOR TO TURNOVER. 14 DEMOLITION: REMOVE ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PLUMBING FIXTURES, PIPING SYSTEMS, ETC...NOT BEING REUSED. DO NOT JUST ABANDON. r CO\ TRACTOR \OTHS: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT, LANDLORD OR TENANT OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BY STATE AND LOCAL CODES WHETHER INDICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AND COMPLIANCE WITH GOVERNING CODES / REQUIREMENTS HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN, HAD AN EXAMINATION AND CODE REVIEW BEEN MADE, WILL NOT BE ALLOWED. MECHANICAL PLAN PROVIDE A 24 "X24" RETURN AIR OPENING I THRU WALL ABOVE CEILING AS HIGH AS POSSIBLE COVER OPENING WITH 1"X1" WELDED WIRE SCREEN. City Of Tukwila I$ I DING DIVISION._ 1 1 01 EXIST'G. 16" DIA. TAP FOR TENANT CONNECTION PROVIDE SPLITTER DAMPER WITH 65/35 SPLIT. PROVIDE A 24 "X24" RETURN AIR OPENING THRU WALL ABOVE CEILING AS HIGH AS POSSIBLE COVER OPENING WITH 1 "X1" WELDED WIRE SCREEN. I .. no.otirtzu NOV 3 rI 2007 NOY 0 i2007 DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817- 251 --8411 Q CO CQ r N Q Q Ln -› 0_ 00 L� Ln s-- J > zQ Q U LJ I- 114 U ° j f) CD REVISIONS SHEET DRAWN: TS DATE: 09.20.07 SCALE: 1/4 "4-17 JOB: MP SOCM M.1 OF 3 E- SHEETS BY 0) N CO co N 0] Ln co LL E 0 LC) 0 O � N N O]- c d TITS AIR DISTRIB,TIO\ 3PV CES MARK MANUF. CATALOG # SIZE MOUNTING MATERIAL FINISH ACCESSORIES BORDER STY_EEMARKS REF' NOTE MOD. NECK SIDE WALL CEILING DUCT STEEL ALUM. DPR. EQUAL GRID FIRE DPR. SD -1 TITUS OMNI 24 "X24" 1037 0 • 0 B • B SD -2 TITUS R —OMNI 22 "0 103 0 0 B 0 A SD -3 TITUS OMNI 12 "X12" 6 "1 • • B • A SD -4 TITUS OMNI 24 "X24" 8 "d) • • B 0 B RG -1 TITUS 355RL 24 "X24" — • • B B 1. CONTRACTOR TO VERIFY FINISHES WITH ARCHITECT. 6. PROVIDE CABLE OPERATED DAMPER FOR AIR OUTLETS IN SHEETROCK CEILINGS. 2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3. ALL AIR OUTLETS SHALL BE SUITABLE FOR THE TYPE OF CEILING CONSTRUCTION USED. COORDINATE BORDER STYLES AND FRAMING. 4. INSTALL FOUR (4) WAY DIFFUSERS WITH BLANK —OFF BAFFLES FOR 2 —WAY AND 3 —WAY BLOW ARRANGEMENTS. 5. PROVIDE 24 x 24 FULL FACE LOUVER FOR TDC DIFFUSERS. EX- A ST EA\ S MANUFACTURER MODEL NO. TYPE C.F.M. S.P. H.P. FAN MOTOR DATA ACC. REF' NOTE NOTES VOLTS PHASE R.P.M. NUTONE 8673P EF -1 100 .125 1/10 120 1 - -- ELECTRIC WATER HEATER TEMPERATURE & PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF DRAIN DISCHARGE 16 GAUGE GALVANIZED SAFETY PAN S WAT 2" WIDE MIN. DUCT STRAP 48" O.C. MAX. RIGID ROUND MET INTERNALLY INSULATED RIGID ROUND D ELBOW INTERNALLY INSULATED ALL METAL DUCT —MUST BE 26 GA. MIN. W /EXCEPTION OF STOCK ROOM VOLUME DAMPER (FOR FINAL BALANCE ADJUSTMENT) MAX. WATWER TEMP. OF 110 DEG. F 3/4" HOT WATER DRAIN VALVE SAFETY MIXING VALVE APPROVED UNDER ASSE 1016 OR 1017 .---1" DRAIN -- DISCHARGE TO /INTO FLOOR DRAIN IN TOILET ROOM EA DUCT ER Nimf 3 SPIN —IN FITTING WITH BALANCING DAMPER AND 45 DEG. EXTRACTOR (DAMPER USED FOR ROUGH BALANCING) DIFFUSER 9LTAIL 2 .r3 /4" HOT WATEREGO FIXTURES (105 VACUUM BREAKER 3/4" COLD WATER SUPPLY 3 /4 "CW SHUT —OFF VALVES —TYPICAL XPANSION TANK. CHECK VALVE UNION(TYPICAL) 9i Tali_ SCALE: NONE SCALE: NONE INTERNALLY INSULATED SPIRAL DUCTWORK MS INSULATED FLEXIBLE DUCT — INSIDE DIAMETER AS NOTED ON PLANS. MAX LENGTH 5' -0" SECURE FLEXIBLE DUCT TO PLENUM AND SPIN —IN FITTING WITH S.S. SCREW CLAMP CEILING DIFFUSER \ CEILING NOTES: *FOR LENGTHS GREATER THAN 5' -0" USE EXTERNALLY INSULATED RIGID ROUND DUCT THE SAME SIZE AS THE FLEXIBLE DUCT FOR THE ADDITIONAL LENGTH. *FLEXIBLE DUCT SHALL BE UL181 APPROVED AND SHALL NOT BE KINKED OR SAGGED. *PROVIDE SPIN—IN FITTING FOR ALL ROUND FLEXIBLE DUCT CONNECTIONS TO RECTANGULAR DUCT. SPIN —IN FITTINGS SHALL BE FACTORY FABRICATED, AND INCLUDE AN AIR EXTRACTOR SCOOP AND A BALANCING DAMPER WITH A LOCKING QUADTANT AND HANDLE. BALANCING SHALL BE AT THE SPIN —IN FITTING AND NOT AT THE AIR DISTRIBUTION DEVICE. WASTE RISER FI/�� 111111111111111111111 lh 11111 ` Ar ∎ ∎ ∎ ∎rA 1 ►lam ∎ �! 1111‘.21” INSULATION DAMPER 1 S.S. SCREW CLAMP DUCT STRAP TYPICAL IN TWO PLACES. MIN. 2" WIDE SPIN —IN FITTING WITH DAMPER AND AIR SCOOP AIR SCOOP SUPPLY DUCT RLbV \G FIXTJRES WC WATER CLOSET — AMERICAN STANDARD "CADET" MODEL #2168.100 (1.6 GAL. /PA) FLOOR MOUNTED, (H.C.) ELONGATED BOWL, TANK TYPE, CHROME TRIP LEVER, WATER SAVER, VITREOUS CHINA, 17" RIM HEIGHT MEETS ADA GUIDELINES AND ANSI REQUIREMENTS FOR PEOPLE WITH DISABILITIES FURNISH WITH, WHITE COLOR OLSONITE MODEL #96 OPEN FRONT SEAT WITH COVER AND CHROME SUPPLY WITH STOP. LAV LAVATORY— AMERICAN STANDARD MODEL #0124.024 WITH FAUCET (MODEL #2985.130) EQUAL BY (H.C.) KOHLER MODEL #K1729, WITH FAUCET (MODEL #K15199) EQUAL BY CRANE MODEL #3 -377 OR ELGER MODEL #051 -1358. FCO FLOOR CLEAN OUT —ZURN #Z1400 —HD -2 (CONC. FLOOR) OR ZN 1400 -2 (TILE FLOOR). EQUALS BY J.R. SMITH OR WADE. WATER HAMMER ARRESTER —SIOUX CHIEF 750 SERIES OR EQUAL BY PRECISION PLUMBING PRODUCTS, INC. FD FLOOR DRAIN —ZURN #Z415, 3" WITH NICKEL BRONZE STRAINER. (PROVIDE WITH TRAP PRIMER IF REQUIRED BY CODE OR SHOWN ON DRAWINGS). WH A.O. SMITH MODEL PV -10, 10 GALLON CAPACITY, COPPER CORE TANK, 1.5 K.W., 120V. DE SPLIT LEVEL WATER FOUNTAIN (DF) OASIS — P8ACSL, TWO STATION WALL MOUNT WATER COOLER. WITH LEFT, RIGHT AND FRONT CONTROLS ON EACH UNIT. BRUSHED STAINLESS STEEL FINISH WHA MS 24" x 24" FLOOR MOUNTED MOP BASIN. FLOORSTONE MODEL 85 NEO ANGLE MOP RECEPTOR WITH AMERICAN STANDARD 8340.242 FAUCET (OR EQUAL) AND HOSE AND MOP HANGER. LAV H.C.) TO TRAP RIMER ( 3" VENT TO LANDLORD'S TOILET VENT SYSTEM. CONNECT TO 4" SANITARY SEWER SYSTEM— V.I.F. T.G.C. SHALL PROVIDE SHUT —OFF VALVES AT ALL CONNECTIONS TO PLUMBING FIXTURES SCALE: NONE NO PLASTIC PIPE IS ALLOWED. WH A In 1/ J MS WAT 1/2" PARTIAL PL PROVIDE BACKFLOW 3 /4 "HW TO WATER HEATER PREVENTION DEVICE AS MOUNTED ABOVE MOP SINK. REF. PER LOCAL DTL #3 THIS SHEET. JURISDICTION. WC MS 3/4 LAV (H.C.) 1/ 1/2" TO FLOOR WC DRAIN'S (H.C.) J 3/4' 1/2" D.F. TRAP PRIMER 1/ LAV (H.C.) R .RISER DIAGRAV SCALE: dp vBl \G PLA\ 4" S.S. VERIFY EXACT LOCATION, FLOW AND SCALE: 1 /4 ' -1' -O" REVIEWED FOR COD COMPLIANCE APPROVED NOV 0 2001 City Of Tukwila ILDI„5 [VISION I- 3 /4 "CW 0 "IA NOV 0 ( ZU NONE DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 81 7- 410 -2858 FAX 817 -251 -8411 GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS ARE A PART OF THIS CONTRACT AND APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENURE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL OTHER TRADES. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE SUBCONTRACTORS WITH A FULL SET OF BID SET DOCUMENTS (INCLUDING SPECIFICATIONS) AND THE COORDINATION OF HIS WORK AND INSPECTIONS AND THE WORK AND INSPECTIONS OF THE SUBCONTRACTORS WITH ALL OTHER TRADES ON SITE CONFORMING TO THE GENERAL CONTRACTOR'S TIME SCHEDULE. 4. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING THE BID TO DETERMINE CONDITIONS AFFECTING THE WORK. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBIUTY IN PERFORMANCE OF WORK. 5. WHEN USED, THE TERM "PROVIDED BY CONTRACTOR' SHALL BE INTERPRETED AS MEANING "FURNISHED AND INSTALLED' WITH THE EXCEPTION WHERE ITEMS ARE "PROVIDED BY IDS' WHICH MEANS 'FURNISHED ONLY' (INSTALLED BY CONTRACTOR), EXCEPT AS SPECIFICALLY NOTED OTHERWISE. GENERAL REQUIREMENTS 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT. SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD SHALL BE PROVIDED BY 111E MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD, AS REQUIRED. FIELD VERIFY THE EXACT TYPE, SIZE AND LOCATION, ETC. OF EXISTING PIPE AND DUCTS IN THE TENANT SPACE PRIOR TD BID. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH 15 NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH 15 OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS STILL RESPONSIBLE FOR PROVIDING THE SYSTEM AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT ACCESS TO ALL EQUIPMENT FOR SERVICE. 5. THE CONTRACTOR SHALL DO ALL CUTTING, CORE DRIWNG, CHASING OR CUTTING SHALL HAVE PRIOR APPROVAL BY THE TENANT'S STORE PROJECT MANAGER CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. AND THE LANDLORD. PATCHING SHALL MATCH, FINISH OF SURROUNDING AREA. CODES DIVISION 15 - MECHANICAL SECTION 15000 MECHANICAL GENERAL PROVISIONS 1. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITYS AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THE CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND CONTRACT IS ISSUED, NO ADDITION REGULATIONS. AFTER CON AL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE TENANT TO THE CONTRACTOR. LICENSES, PERMITS, INSPECTIONS & FEES 1. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED CR RELATED TO THIS WORK. 2. FURNISH THE TENANTS PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT SUBSTANTIAL COMPLETION DATE OF PROJECT. DRAWINGS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL DUCT AND PIPING OFFSETS, FITTINGS AND ACCESSORIES THAT MAY BE REQUIRED. 2. THE LAYOUT SHOWN ON THE DRAWINGS 15 BASED ON A PARTICULAR MAKE OF EQUIPMENT. IF ANOTHER MAKE OF EQUIPMENT IS USED WHICH REQUIRES MODIFICATION OR CHANGE OF ANY DESCRIPTION FROM THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHAM BE RESPONSIBLE AS PART OF THIS WORK, FOR MAKING ALL SUCH MODIFICATIONS AND CHANGES, INCLUDING MOSE INVOLVING OTHER TRADES WITH THE COST THEREOF INCLUDED IN THIS BID. IN SUCH CASE, CONTRACTOR SHALL SUBMIT DRAWINGS AND SPECIFICATIONS PRIOR TO STARTING WORK SHOWING ALL SUCH MODIFICATIONS AND CHANGES. THE PROPOSAL SHALL BE SUBJECT TO THE APPROVAL OF THE TENANTS PROJECT MANAGER. EXISTING SHELL SPACE CONDITONS 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING MECHANCIAL WORK SHOWN ON THE MECHANCIAL DRAWINGS AND THE MECHANCIAL DEMOLITION SHOWN ON THE ARCHITECTURAL DRAWINGS. 2. THE CONTRACTOR SHAM INCLUDE, AND WILL BE HEW RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED UNLESS NOTED FOR REUSE OR RECONFIGURATION ON PLANS. ROOF PATCHING SHALL BE PERFORMED AT THE CONTRACTOR'S EXPENSE BY A ROOFING CONTRACTOR APPROVED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF (ABOVE THIS SPACE) NOT APPLICABLE TO THE NEW WORK OR PART OF THE LANDLORD'S OR ANOTHER TENANTS ACTIVE SYSTEM MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. 3. ACTIVE LANDLORD OR OTHER TENANT SERVICES ENCOUNTERED IN WORK SHALL BE PROTECTED AND SUPPORTED. IF EXISTING SERVICES NOT ANTICIPATE) REQUIRE RELOCATION, CONTACT THE DISNEY STORE PROJECT MANAGER IMMEDIATELY. AM COSTS FOR REPAIR OF DAMAGES TO ACTIVE LANDLORD OR OTHER TENANT SERVICES DURING CONSTRUCTION SHALL BE PAID FOR BY THE CONTRACTOR CAUSING THE DAMAGE. 4. 11E -INS AND MODIFICATIONS TO EXISTING LANDLORD SERVICES MUST BE DONE WITH MINIMUM INTERRUPTION OF LANDLORD OPERATION AND DURING HOURS SPECIFIED BY THE LANDLORD. THE CONTRACTOR 15 RESPONSIBLE FOR CONFIRMING EXACT WORKING HOURS OF THIS WORE( WITH THE LANDLORD PRIOR TO SUBMITTING HIS BID. THE CONTRACTOR SHALL INCLUDE IN HIS BID, ALL PREMIUM TIME REQUIRED TO PERFORM MODIFICATIONS DURING OTHER THAN NORMAL WORKING HOURS. ALL SUCH WORK MUST BE COORDINATED WITH THE LANDLORD. G. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE THE DISNEY STORE'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, THE TENANT PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CO D P CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION SATION PERMITTED. H TRADE NAMES AND MANUFACTURERS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS. THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM STANDARD FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BEIIER IN ALL ASPECTS TO THAT SPECIFIED WU BE SUBJECT TO APPROVAL IN WRITING BY THE DISNEY STORE'S PROJECT MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE I. SHOP DRAWINGS 1. SUBMIT TWO COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR ALL EQUIPMENT AND DUCT FABRICATION DRAWINGS TO THE GENERAL CONTRACTOR FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. SUBMISSIONS MUST BE EARLY ENOUGH TD ALLOW THE TENANTS PROJECT MANAGER EIGHT WORKING DAYS FOR REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE GENERAL CONDITIONS USING THE MANUFACTURER'S USTED ON THE DRAWINGS. SHOP DRAWINGS SHALL INCWDE ALL DATA THAT PERTAINS TO THE REQUIREMENTS SET FORTH ON THE DRAWINGS AND IN THE SPECIFICATIONS. THE SUBMITTAL SHALL INCLUDE BUT NOT LIMITED TO CUTS OR CATALOGS INCLUDING DESCRIPTIVE LITERATURE AND CHARACTERISTICS OF EQUIPMENT SHALL SHOW MAJOR DIMENSIONS, ROUGHING -IN DATA, CAPACITY, CURVES, PRESSURE DROP, CODE COMPLIANCE, MOTOR AND DRIVE DATA AND ELECTRICAL DATA. OBSERVE SPECIAL INSTRUCTIONS WHEN REQUIRED. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL AND SUB- CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS TAKE PLACE. LACK OF SUCH CONTRACTOR'S REVIEW AND APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE TENANT'S PROJECT MANAGER. ALL SHOP DRAWINGS MUST APPEAR IN THE OPERATION AND MAINTENANCE MANUALS SENT TO THE HOME OFFICE OF THE TENANTS PROJECT MANAGER AT JOB COMPLETION. J. RECORD DRAWINGS 1. THE CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. D. EXACT ROUTING OF ALL SANITARY AND DOMESTIC WATER PIPING UNDER FLOOR. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. THE DRAWINGS ARE TO BE SENT TO THE HOME OFFICE OF THE DISNEY STORE'S PROJECT MANAGER. K. GUARANTEE 1. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY THE TENANT'S PROJECT MANAGER. PROVIDE EXTENDED WARRANTIES AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. IN CASE OF REPLACEMENT OR REPAIR OR EQUIPMENT DUE TO FAILURE WITHIN GUARANTEE PEROID, GUARANTEE ON THAT PORTION OF WORK SHALL BE EXTENDED FOR A PEROID OF ONE (1) YEAR FROM DATE OF SUCH REPLACEMENT OR REPAIR. L OPERATIONS MANUALS 1. ONE COPY OF EACH OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT FURNISHED ON JOB SHALL BE COLLECTED AND INSERTED IN A 3" THREE RING BINDER AND SENT TO THE OFFICE OF THE TENANTS PROJECT MANAGER. EACH NOTEBOOK SHALL INCLUDE BUT NOT BE LIMITED TO INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS, PAMPHLETS OR BROCHURES APPROVED SHOP DRAWINGS AND WARRANTIES OBTAINED FROM EACH MANUFACTURER OF PRINCIPAL ITEMS OF EQUIPMENT. M. SLEEVES 1. THE CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL_ EXTEND THROUGH ITS RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "REV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THE FIRE RATING OF THE FLOOR OR WALL CONFORM TO U.L ASSEMBLY RATING OF FLOOR OR WALL 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FGR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. 4. DUCT SLEEVES TO BE MINIMUM 14 GAUGE STEEL N. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CUPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL CONCRETE, OR MASONRY, BUT NOT TO PIPING OR DUCTWORK. HANGING FROM METAL DECK 15 NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, ACCESS DOORS AND OTHER EQUIPMENT SERVICE REQUIREMENTS AND /OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR AM INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTAL. 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED FROM ONE ANOTHER_ 0. ACCESS DOORS 1. FURNISH STEEL ACCESS DOORS AND FRAMES, MIN. 16' X 20' OR AS SHOWN ON DRAWINGS, TO GENERAL CONTRACTOR FOR ALL LOCATIONS WHERE NECESSARY TO PROVIDE ACCESS TO CONCEALED VALVES, AND OTHER EQUIPMENT REQUIRING SERVICE OR INSPECTION. LOCATION. TYPE, SIZE AND NUMBER AS DETERMINED BY CONTRACTOR AND APPROVED BY THE TENANTS PROJECT MANAGER TO SUIT EQUIPMENT REQUIREMENTS. GENERAL CONTRACTOR WILL INSTAL ACCESS DOORS AND FRAMES. 2. ACCESS DOORS LOCATED IN ARE -RATED WALLS, FLOORS, CEIUNG -FLOOR OR CLIUNG -ROOF ASSEMBUES SHALL BE FIRE RATED, UNDERWRITER'S LABORATORIES, INC., LISTED AND LABELED 3. ACCESS DOORS SHALL BE FLUSH TYPE, MANUFACTURED FROM NO. 14 GAUGE STEEL. COMPLETE WITH FLUSH FLANGE TYPE FRAMES MANUFACTURED FROM NO. 16 GAUGE STEEL, PROVIDED WITH ANCHORS. ACCESS DOORS SHALL BE SUITABLE FOR INSTALLATION IN WALL OR CETUNG MATERIALS SHOWN IN ROOM FINISH SCHEDULES. P. ELECTRICAL MOTORS 1. FURNISH, INSTALL AND ALIGN ALL MOTORS REQUIRED FOR THIS EQUIPMENT. UNLESS THEY ARE FACTORY INSTALLED ON THE UNIT, ALL STARTERS AND ASSOCIATED WIRING AND SAFETY SNATCHES FOR SUCH MOTORS SHALL BE FURNISHED BY THE MECHANICAL CONTRACTOR AND INSTALLED BY THE ELECTRICAL CONTRACTOR. STARTERS SHALL MEET ALL REQUIREMENTS AS DEFINED IN THE ELECTRICAL DIVISION OF THE SPECIFICATIONS. 2. DESIGN, CONSTRUCTION AND PERFORMANCE CHARACTERISTICS OF MOTORS SHALL CONFORM TO ALL APPLICABLE PROVISIONS OF LATEST NEMA, ANSI,ISEE STANDARDS FOR ELECTRICAL EQUIPMENT. ALL MOTORS SHALL BE SUITABLE FOR OPERATION ON VOLTAGE VARIATION OF PLUS OR MINUS 10%, 40 DEGREES C AMBIENT TEMPERATURE; HAVE A SERVICE FACTOR OF NOT LESS THAN 1.15. Q. LOW VOLTAGE (24 VOLT) WIRING 1. THE CONTRACTOR IS TO INSTALL ALL LOW VOLTAGE WIRING REQUIRED FOR THE EQUIPMENT. THIS WORK INCLUDES ALL TRANSFORMERS AND DEVICES TO MAKE THIS A COMPLETE FUNCTIONAL SYSTEM. 2. ALL WORK IS TO CONFORM TO THE LATEST ADDITION N.E.0 AND TO DIVISION 16 ELECTRICAL SPECIFICATIONS. 3. ANY CONDUIT REQUIRED BY CODE DR THE LANDLORD WILL BE INSTALLED BY THE ELECTRICAL SUBCONTRACTOR. DIVISION 15 - MECHANICAL SEC11ON 15200 A. SCOPE OF WORK PLUMBING 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PWMBING SYSTEMS AS SHOWN ON THE DRAWINGS. CALLED FOR iN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TD INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBIUTIES) A. COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. B. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. C. PLUMBING FIXTURES AND EQUIPMENT AS SCHEDULED. D. COMPLETE NATURAL GAS PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). E. TESTS AND ADJUSTMENTS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXIST1NG WATER, GAS. WASTE, VENT, OR DRAINAGE ONES TO FACIUTATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL B. PLUMBING EQUIPMENT C. GENERAL PIPING REQUIREMENTS 1. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY THE TENANTS PROJECT MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMUM OF 50 P. 2. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 3. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 4. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE. D. PIPING 1. SANITARY PIPING - A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT, CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2' OR SMALLER MAY BE GALVANIZED STEEL B. JOINTS: BELOW FLOOR SLAB - COMPRESSION TYPE PLASTIC SEAL (HUB AND SPIGOT). ABOVE FLOOR SLAB - NEOPRENE SEAUNG SLEEVE WITH STAINLESS STEEL SHIELD AND CLAMP WITH APPROVED NEOPRENE - BASED LUBRICANT, (HUBLESS). GALVANIZED VENT - SCREWED JOINTS WITH TEFLOW TAPE ON MALE THREADS. C. PITCH WASTE LINES 2' AND SMALLER NOT LESS THAN 1/4' PER FOOT. PITCH LARGER MAINS NOT LESS THAN 1/8' PER FOOT. D. INSTALL A CLEANOUT AT BASE OF EACH SOIL STACK, AT EACH CHANGE IN DIRECTION, AT INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY LOCAL CODE CLEANOUTS SHALL NOT BE INSTALLED IN PUBLIC AREAS WITHOUT SPECIFIC PERMISSION BY THE TENANTS PROJECT MANAGER; BUT WHERE NECESSARY, THE WALL COVERS ARE TO BE STAINLESS STEEL AND THE FLOOR COVERS ARE TO BE BRASS (FLUSH WITH FINISHED FLOOR). PROVIDE COVERS MTH INSET AREA FOR CARPETED FLOOR LOCATIONS. ALL CLEAN -OUT LOCATIONS SHALL BE APPROVED BY THE TENANTS PROJECT MANAGER. E. INSULATE ALL HORIZONAL RUNS OF PIPING LOCATED IN CEILING SPACES WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. F. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH TRUEBRO MODEL 102W ° HANDI LAV GUARD" INSULATION KIT. 2. CONDENSATE PIPING SHALL BE TYPE GALVANIZED PIPE WITH SCREWED FITTINGS WITH DIELETRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. POTABLE WATER PIPING: A. BELOW GRADE: TYPE 'M' COPPER TUBE FOR PIPE. ERASE ALL JOINTS B. ABOVE GRADE: TYPE 'M' COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95 -5 TIN-ANTIMONY SOLDER. C. INSTALL AIR CHAMBER SHOCK ABSORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. D ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE . PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. E. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. REFER TO PLANS TO DETERMINED IF WATER METER 15 REQUIRED. F. SECURE PIPE AT ANGLE STOPS. G. PROVIDE FLEXIBLE INSERTS AT ALL PIPE PENETRATIONS THROUGH FRAMING TO KEEP PIPES FROM HITTING FRAME WHEN IN OPERATION. 4. INSULATION A. INSULATE ALL WATER AND INTERIOR CONDENSATE PIPING WITH 1' THICK (K =0.23 0 75 F) SNAP -ON FIBERGLASS PIPE INSULATION WITH AN All SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD RATING OF 25 AND SIMOKE DEVELOPED RATINGS OF 50. APPROVED MANUFACTURER: MANVILLE MICRO -LOK. 5. TEST & STERILIZATION A. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: 1. TEST POTABLE WATER PIPING AND CONDENSATE PIPING AT 125 PSIG FOR SIX HOURS. 2. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. AM JOINTS SHALL BE GAS AND WATER TIGHT. 3. TEST GAS PIPING WITH PER NFPA 54 CODES. 4. STERILIZE POTABLE HOT & COW WATER UNES UPON COMPLETION OF SYSTEM. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. DIVISION 15 - MECHANICAL SECTION 15300 FIRE PROTECTION A. SCOPE OF WORK 1. THE F.P. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACIU11E5 NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE WITH NFPA -13, LOCAL CODES, LANDLORD'S CRITERIA, AND INSURANCE CARRIERS FOR THE MALL AND TENANT. B. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. C. DESIGN DRAWINGS, CALCULATIONS, SUBMITTALS AND APPROVALS. D. PERMITS, FEES, AND CHARGES. E. TESTS AND TEST CERTIFICATES. F. COST FOR SHUT DOWN FEES. 2. THE CONTRACTOR THAT DOES THE ACTUAL SPRINKLER WORK 15 REQUIRED TO BE A LANDLORD APPROVED SPRINKLER CONTRACTOR. 3. BEFORE STARTING WORK, THE CONTRACTOR SHAL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 4. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL B. SHOP DRAWINGS 1. THE FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS FOR HIS WORK. SUBMIT TWO (2) COPIES TO GENERAL CONTRACTOR FOR APPROVAL NO WORK SHAL BEGIN UNTIL THE TENANT'S PROJECT MANAGER APPROVES IN WRITING THE HEAD AND PIPING LOCATIONS. 2. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, CALCULATIONS, HEAD TYPES AND COLORS TO AL AUTHORITIES HAVING JURISDICTION FOR APPROVAL NO WORK SHALL BEGIN UNTIL AL APPROVALS HAVE BEEN RECEIVED. 3. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHAL BE FORWARDED TO THE LANDLORD'S AGENT AND TO THE TENANT'S PROJECT MANAGER. C. EQUIPMENT 1. SPRINKLER HEADS: A. ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS IN EXISTING STORES TO BE REPLACED), U.L, F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER CO., GLOBE, GRINNELL, RELIABLE, STAR, OR VIKING. B. ALL SPRINKLER HEADS SHALL BE RATED FOR 165 DEG. F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. C. ALL SALES FLOORS HEADS ARE TO HAVE BE FACTORY APPUED COLOR FINISH TO MATCH ARCHITECTURAL C ©LING FINISH. VERIFY HEAD TYPES AND COLORS WITH SPECIFICATIONS ON SHEET A010 AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. D. SPRINKLER HEAD TYPES: SEE SHEET M1.0 FOR ADDITIONAL INFORMATION. D. GENERAL PIPING 1 A FIRE PROTECTION SYSTEM STUB IN SHALL BE FURNISHED BY THE LANDLORD. SPRINKLER SPACING SHALL NOT EXCEED 1.30 5Q. FT. IN "SALES" AREAS AND 100 SQ. FT. IN 'STOCK' AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. 2. ALL SPRINKLER UNES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH UGHTS, DUCTS, PIPES, STORAGE DECK, ETC. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER ONES, LIGHTS, DIFFUSERS. GRILLES AND REGISTERS PRIOR TO INSTALLATION. HORIZONTAL SPRINKLER RUNS AT MERCHANDISE SOFFITS SHALL BE PLACED INSIDE SOFFIT STRUCTURE. VERTICAL DROPS FROM CEILING TO MERCHANDISE SOFFIT SHALL BE LOCATED FLUSH AGAINST DEMISING WALLS. 3. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY THE LOCAL FIRE PROTECTION OFFICIAL AND THE TENANT'S PROJECT MANAGER BEFORE INSTALLATION. HEADS MUST BE LOCATED IN THE CENTER OF CEILING TITLES AND IN A SYMMETRICAL PATTERN WITH OTHER CEILING FIXTURES. ADDITIONAL MONIES WILL NOT BE ALLOCATED FOR ADDITIONAL HEADS REQUIRED BY FIELD FIRE INSPECTOR AFTER BIDS ARE ACCEPTED. HEADS IN MERCHANDISE BAYS SHALL BE CENTERED SIDE TO SIDE AND FRONT TO BACK. 5 PROVIDE AND INSTALL A VALVED TEST CONNECTION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR. OR INSURANCE CARRIER. COORDINATE LOCATION WITH THE TENANT'S PROJECT MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH -IN. 6. SPRINKLER HEADS LOCATED IN STOCK, CORRIDOR OR TOILET ROOM C©LNGS OR WALLS BELOW 8' -0" ABOVE THE FINISHED FLOOR ARE TO BE PROTECTED WITH APPROVED GUARDS. E. PIPING: 1. SCHEDULE 40, BLACK STEEL PIPE, ASTM A -53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B-36 -10-70 FOR WROUGHT STEEL PIPE. 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. 4. VICTAUUC TYPE COUPUNGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. F. TESTS 1. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. 2. PROPERLY COMPLETED AND SIGNED 'SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES' SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND THE TENANTS PROJECT MANAGER. DIVISION 15 - MECHANICAL SECTION 15500 HEATING. VENTILATION, AND AIR CONDITIONING A. SCOPE OF WORK 1. THE HVAC CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT. SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS BY JOB CONDITIONS, TO INCLUDE REQUIRED B INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:(REFER TO RESPONSIBIUTY SCHEDULE FOR EXACT RESPONSIBILITIES) A. B. D. E. F. G. H. J. HVAC UNITS, EQUIPMENT. AND APPURTENANCES. DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. CHIT I FD WATER PIPING AND INSULATION (AS APPLICABLE, REFER TO PLANS). DIFFUSERS, GRIMES, AND REGISTERS. CURBS AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). TESTING, ADJUSTING, AND BALANCING. OPERATIONS MANUALS. TEMPERATURE CONTROLS AND RELATED DIAGRAMS. SEQUENCES OF OPERATION. CONNECTION TO ANY LANDLORD ENERGY MANAGEMENT SYSTEM. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS 10 SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. B. HVAC EQUIPMENT 1. PRIMARY HEATING, VENTILATION AND AIR CONDITIONING UNITS. A. PRIMARY HEATING, VENTILATION, AND NR CONDITIONING UNITS ARE TO BE BY CARRIER CORPORATION AS SCHEDULED. AL COMPRESSORS ARE TO INCLUDE A 5 -YEAR EXTENDED WARRANTY. B. NOT USED C. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH AL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. D. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST HAVE A CONDENSATE DRAIN AND BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. E. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO PROTECT ENTIRE UNIT. PROVIDE CONDENSATE PUMPS, AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. 2. TOILET EXHAUST FANS A. WHERE SHOWN ON DRAWINGS, PROVIDE A TOILET EXHAUST FAN UNIT COMPLETE WITH GRAVITY BACK DRAFT DAMPERS. AL DUCTWORK, ROOF OPENINGS AND CAPS NECESSARY TO PROVIDE A COMPLETE EXHAUST SYSTEM SHAD- BE PROVIDED BY THE CONTRACTOR. REFER TO PLANS FOR APPLICABILITY. 3. VIBRATION ISOLATION DEVICES A. VIBRATION ISOLATION DEVICES SHALL BE PROVIDED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, AIR HANDLERS, FAN POWERED VAV BOXES, ETC.) AND STRUCTURE B. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. C. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER AUGNMENT AND LOADING. AVOID ° GROUNDING" THE ISOLATOR. D. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS. EQUIPMENT, ETC. E CONSULT MANUFACTURER FOR APPLICATION DATA 4. VARIABLE AIR VOLUME BOXES (VAV) A WHERE SHOWN ON DRAWINGS, INSTALL VAV BOXES COMPLETE WITH CONTROLS. (FANS AS REQUIRED). ALL DUCT CONNECTIONS FLEXIBLE DUCT /PIPE CONNECTIONS SHALL BE PROVIDED TO THE THE TENANTS PROJECT MANAGER PRIOR TO INSTALLATION. 5. CURBS AND STEEL FRAMING FOR SUPPORT A. THIS CONTRACTOR WILL PROVIDE ALL NECESSARY CURBS AND STEEL FRAMING REQUIRED TO INSTALL AL HVAC EQUIPMENT AS DESCRIBED OR IMPLIED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14' HIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED. INSULATE UNDER THE COMPRESSOR SECTION TO PREVENT CONDENSATION. ALL CURBS MUST BE INSTALLED SO THAT TOP OF CURBS ARE 'DEAD" LEVEL ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. C. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO APPROVAL BY THE TENANTS PROJECT MANAGER. SIGNIFICANT DEVIATIONS FROM DESIGN MUST BE APPROVED BY THE TENANT'S PROJECT MANAGER PRIOR TO FABRICATION OR INSTALLATION. ALL DUCT MAINS ARE TO BE RECTANGULAR UNLESS NOTES OTHERWISE. ALL DUCT BRANCHES (IF REQUIRED) TO DIFFUSERS ARE TO BE ROUND RIGID DUCT. (FLEXIBLE DUCT CONNECTIONS TO THE DIFFUSER ARE NOT ALLOWED ON THE SALES FLOOR OR EXPOSED CEILINGS) 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR DUCTS WITH GALVANIZED SHEET STEEL IN ACCORDANCE WITH SMACNA ° HVAC DUCT CONSTRUCTION STANDARDS' OF THE LATEST EDITION. CONFORM TO THE REQUIREMENTS IN THE REFERENCED STANDARD FOR METAL THICKNESS, REINFORCING TYPES AND INTERVALS, 11E ROD APPUCATIONS, AND JOINT TYPES AND INTERVALS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: (VERIFY WHETHER RETURN OR EXHAUST DUCT 15 POSITIVE OR NEGATIVE PRESSURE). A. SUPPLY DUCTS: 2 INCHES WATER GAUGE, POSITIVE PRESSURE B. RETURN AND EXHAUST DUCTS: 2 INCHES WATER GAUGE, NEGATIVE PRESSURE. PRESSURE TEST DUCTS FOR LEAKAGE. REMAKE LEAKING JOINTS AND APPLY SEALANTS AS REQUIRED TO FABRICATE A SYSTEM THAT DOES NOT EXCEED 5% LEAKAGE OR LESS AS STATED BY PRESSURE CLASS RATINGS IN SMACNA STANDARDS. 4. AS A MINIMUM, CROSSBREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/8° WIDE X 3/16 DEEP ON 12 CENTERS TO PREVENT VIBRATIONS. 5. INSTALL DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS. 6. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 7. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 1/2'X1-1/2" X1 /8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SIUCONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 8. ALL TRAVERSE JOINTS AND SEAMS IN SUPPLY AIR DUCT SHALL BE SEALED AIR TIGHT WITH DAP CMC DUCT SEALER. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. 9. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 10. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 11. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION 15 EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY THE TENANT'S PROJECT MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS. .. . 12. FLEXIBLE CONNECTIONS A. FLEXIBLE COLLARS SHALL BE PROVIDED IN Al CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, AIR HANDLERS, FAN POWERED VAV BOXES, ETC.) AND DUCTS OR CASINGS. ALSO, PROVIDE FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. B. FLEXIBLE CONNECTIONS SHALL CONSTRUCTED OF NEOPRENE - COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. C. FLEXIBLE CONNECTION 5 TO BE RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. 13. FIRE DAMPERS A. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED. B. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 DEG. F FUSIBLE LINK, TYPE A, AS MINIMUM. C. PROVIDE ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND CODE REQUIREMENTS. D. PROVIDE DUCT ACCESS DOORS IN AN ACCESSABLE LOCATION FOR ALL FIRE DAMPERS. DOOR IS TO BE 20 GA GALVANIZED DOOR WITH QUICK - OPENING LATCH AND PIANO HINGE. 14. FLE7QBLE AIR DUCT A. FLEXIBLE AIR DUCT SHALL BE 1' INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC. CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. B. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS WITH PRIOR APPROVAL FROM THE TENANTS PROJECT MANAGER. C. FLEXIBLE DUCT SHAM NOT EXTEND OVER 5' -0' IN LENGTH AT ANY ONE LOCATION AND 15 ONLY USED IN CONCEALED LOCATIONS IF AT ALL D. HYDRONIC PIPING 1. PROVIDE A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC SYSTEM IS REQUIRED. 2. PIPING A HYDRONIC PIPING FOR CHILLED WATER AND /CR HEATING WATER AND /OR CONDENSER WATER SHALL BE ASTM A -120, SCHEDULE 40, ERW, BLACK STEEL PIPE WITH PLAIN ENDS. INSTAL STEEL PIPE WITH WELDED JOINTS WHERE PIPE 5 2 -1/2 INCH AND LARGER INSTALL SILO_ PIPE WITH THREADED JOINTS AND FITTINGS OR INSTALL TYPE ° K ° ANNEALED TEMPERED COPPER TUBE WITH SILFOS JOINTS FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMANCE WITH ASTM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER IS MOST STRINGENT. UNIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE REQUIRED. B. ALL PIPING AND EQUIPMENT SHAL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. C. ALL HYDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PIPING SYSTEM SHALL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE STRAINER SCREENS. FILL TENANTS SYSTEM WITH DOMESTIC WATER AND VENT AL PIPING AND EQUIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NOT FILL TENANTS SYSTEM WITH WATER FROM THE LANDLORD'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO S0 FROM THE LANDLORD'S FIELD REPRESENTATIVE D. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHAL OBTAIN WRITTEN CONFIRMATION FROM THE LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHING, AND PROPER FIWNG OF THE TENANTS SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANT'S SYSTEM 15 READY TO BE CONNECTED TO THE LANDLORD'S SYSTEM. 3. VALVES A. GATE VALVES, 2 -INCH AND SMALLER CLASS 150, BODY AND UNION BONNET OF ASTM B 62 CAST BRONZE WITH THREADED OR SOLDER ENDS, INTEGRAL SEAT, RENEWABLE SOLID BRONZE WEDGE DISC. RISING STEM, SCREWED BONNET AND RE- PACKABLE UNDER PRESSURE. BALL VALVES ARE ACCEPTED AS AN EQUAL SUBSTITUTION. B. GATE VALVES, 2 -1/2 INCH AND LARGER: CLASS 125 CAST IRON BODY, RENEWABLE BRONZE SEATS AND SOLID WEDGE DISC, RISING STEM, FLANGED ENDS, AND RE- PACKABLE UNDER PRESSURE. C. SWING CHECK VALVES, 2 -INCH AND SMALLER: CLASS 150, CAST BRONZE BODY AND CAP CONFORMING TO ASTM B 62 WITH HORIZONTAL SWING, Y- PATTERN, RENEWABLE BRONZE DISC, AND HAVING THREADED OR SOLDERED ENDS. D. SWING CHECK VALVE, 2 -1/2 INCH AND LARGER CLASS 125 CAST IRON BODY AND BOLTED CAP, HORIZONTAL SWING, RENEWABLE BRONZE DISC, FLANGED ENDS AND CAPABLE OF BANG REFITTED WHILE THE VALVE REMAINS IN THE LINE. E. COMBINATION BALANCING AND SHUT -OFF VALVES: BELL & GOSSETT CIRCUIT SETTER WITH LOCKING SETPOINT. A CIRCUIT SETTER BALANCE WHEEL MUST BE INCLUDED WITH 0 & M MANUAL F. FLOW METER: BELL AND GOSSE7T THERMOFLO INDICATOR MODEL TA. 4. PIPING SPECIALTIES 1 A. PRESSURE/TEMPERATURE TEST PLUGS ( PETE'S PLUG) - 1/4 INCH NPT FITTINGS TO RECEWE EITHER A TEMPERATURE OR PRESSURE PROBE, 1/8 INCH O.D. FITTING AND CAPS SHALL BE BRASS WITH VALVE CORE OF NGRDEL, RATED AT 400 PSIG, 0 DEG. F TO 200 DEG. F. B. STRAINERS - 'Y PAI IERN STRAINERS, 125 PSIG, CAST IRON BODY WITH PERFORATED STAINLESS STEEL SCREEN, THREADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2 -1/2 INCHES AND LARGER. SCREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INCH FOR CHILLED OR CONDENSER WATER. PROVIDE WITH BLOWDOWN VALVE WITH HOSE END FITTING. C. THERMOMETERS - DIE CAST ALUMINUM, 9" INDUSTRIAL MERCURY THERMOMETER, FULLY ADJUSTABLE WITH CLEAR ACRYLIC WINDOW AND BRASS SEPARABLE SOCKET. D. MANUAL AIR VENTS - 1/8" COIN- OPERATED VENT. PROVIDE AN AIR CHAMBER CONSISTING OF A 3/4" NIPPLE AND BUSHINGS. 5. GENERAL INSTALLATION A. INSTALL WATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. MAKE CHANGES IN DIRECTION WITH FITTINGS. B. BRANCHES TO UNITS BELOW MAINS TO BE TAKEN ROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. C. HANGERS SHALL BE SIZED AND INSTALLED FOR THE OUTSIDE DIAMETER OF THE INSULATED PIPE. INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND PIPE INSULATION. D. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED FROM ONE ANOTHER. E. SEE PLANS FOR APPLICABLE DETAILS. F. ALL PRESSURE PIPING SYSTEMS INSTALLED SHALL CONFORM TO THE REQUIREMENTS OF THE STATE PIPING AND WELDING CODES. G. INSTALL VALVES AT LOW POINTS FOR DRAINING EACH SYSTEM AND INSTALL MANUAL VENTS AT ALL HIGH POINTS OF EQUIPMENT AND PIPING IN THE SYSTEM TO PROPERLY REMOVE ENTRAPPED AIR. 6. INSULATION A. ALL HYDRONIC PIPING FOR CHILLED WATER AND /OR HEATING WATER, VALVES, FITTINGS, AND ACCESSORIES SHALL BE INSULATED. FOR PIPE SIZES UP TO 2 INCHES, INSULATE WITH 1 INCH THICK (K =0.23 ® 75 F) FIBERGLASS INSULATION WITH All SERVICE JACKET AND VAPOR BARRIER. FOR PIPE SIZES 2-1/2 INCHES AND LARGER, INSULATE WITH 1 -1/2 INCH THICK (K =0.23 ® 75 F) FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. B. INSULATION AT ALL HANGERS FOR PIPING 2 -1/2 INCHES AND LARGER SHALL BE HARD AND NON - COMPRESSIBLE. C. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 TO CONFORM WITH THE REQUIREMENTS OF THE NEPA. 15. SUPPLY AIR TAKE -OFF FITTINGS A. PROVIDE CONICAL OR "BELL - MOUTH" TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALL PER MANUFACTURER'S INSTRUCTIONS. B. PROVIDE 45 DEG. RECTANGULAR TAKE -OFFS FROM MAIN DUCTWORK TO RECTANGULAR BRANCHES. 16. DAMPERS A PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH DUCT AND AS SHOWN ON PLANS TO FACIUTATE AIR BALANCING. B. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, YOUNG'S REGULATORS SHALL BE USED. C. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR, RELIEF AIR, OR RETURN AIR DUCTS ARE TO BE OF OPPOSED BLADE TYPE. ALL OUTSIDE AIR DUCT DAMPERS MUST ALSO BE OF THE LOW LEAKAGE TYPE. D. ALL MOTORIZED DAMPERS NOT FURNISHED WITH EQUIPMENT ARE TO BE HONEYWELL DAMPERS. 17. DIFFUSERS, GRILLES, AND REGISTERS A. PROVIDE DIFFUSERS GRILLES AND REGISTERS AS SCHEDULED. DEVICES TO BE COMPLETE WITH DAMPERS FRAMES AND ALL ACCESSORIES. FINISH AS INDICATED. B. INSTALL ALL AIR DEVICES AS LOCATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN. C. APPROVED MANUFACTURERS: KRUEGER. NO SUBSTITUTIONS WITHOUT WRITTEN APPROVAL FOR THE TENANT'S PROJECT MANAGER. 19. DUCTWORK INSULATION A. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. ALL ROUND AND OUTSIDE AIR DUCTWORK ABOVE THE FINISHED CEILING SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1 -1/2 "THICK, 1 -1/2 LB. DENSITY DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER 15 TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED 50 THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. C. PROVIDE 1" THICK 1 1/2 LB. INTERNAL DUCT LINER ON ALL RETANGULAR SUPPLY DUCTS WHERE INDICATED ON PLANS. D. ALL INSULATION SHAM HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. 20. SYSTEM CLEANOUT A. DUCTWORK AND AIR HANDLING EQUIPMENT 15 TO BE CLEANED OUT AND BLOWN OUT BEFORE PAINTING 15 STARTED BY THE GENERAL CONTRACTOR. B. FILTERS MUST BE IN UNITS AT ANY TIME FANS ARE OPERATED. B. E. SYSTEM TESTING, ADJUSTING, AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WI-10 15 CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING SHALL BE MADE BY THE GENERAL CONTRACTOR. 2. THE HVAC CONTRACTOR SHAL_ INSTAL NEW ELTERS IN ALL UNITS PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION. 3. BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5% OF THAT INDICATED ON THE DRAWINGS. ANY REWIRED CHANGES IN SHEAVES, BELTS, PULLEYS. DR THE ADDITION OF DAMPERS REQUIRED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO THE TENANTS PROJECT MANAGER 4. THE BALANCE REPORT SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. B. INSTRUMENTATION UST WITH LAST CALIBRATION DATES. C. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. D. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. E. MOTOR NAMEPLATE DATA WITH ACTUAL REID VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. F. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. G. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AT FULL COOUNG. H. WATER BALANCE DATA INCLUDING GPM WITH INLET AND OUTLET TEMPERATURE AND PRESSURE READINGS (WHERE APPLICABLE). MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. ANAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). K. INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. 6. THREE STAMPED ORIGINALS OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO THE TENANTS PROJECT MANAGER FOR APPROVAL 7. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED IN THESE DRAWINGS. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT THE TENANT DEEMS NECESSARY AT NO ADDITIONAL COST TO THE TENANT. 8. FINAL BALANCE REPORT SHALL BE INCLUDED IN THE OPERATION & MAINTENANCE MANUALS. F. FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, THE TENANT SHALL HAVE THE RIGHT TO HAVE AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING AL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS AT NO COST TO THE TENANT. J. CODE COMPLIANCE A PPROVED NOV : j () 2007 FE .. 4 , ,,/ m NOV 0 r Zt? l r REVISIONS co ("7 r ❑) a 0 L'7 co W LC) LC7 L_L_I (N Q L(7 r < Q Cn Li Q ZZCCi-Ln Z o Da z N off -o zz I JOB: MP_SOCM f 0 ° co 0 co L'17 Cl) ai 7 c U O •2 cti 1W U) m co (o DATE: 09.20.07 SCALE: 1/4 " -Ow DRAWN: TAS SHEET n M.3 4 4 Lre c BY 3 OF 3 M.HEETS