Loading...
HomeMy WebLinkAboutPermit PG07-305 - GATEWAY CORPORATE CENTERGATEWAY CORP CENTER 12783 GATEWAY DR PGO7-305 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Plumbing /Gas Piping: Fees Collected: doc: UPC - 10/06 2716000060 12783 GATEWAY DR TUKW City..af Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us GATEWAY CORPORATE CENTER 12783 GATEWAY DR , TUKWILA WA RREEF AMERICA REIT II CORP/ PO BOX 4900 #207 , SCOTTSDALE AZ KEO TORRE 727 KENYON ST , SEATTLE WA Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA Contractor License No: EVERGRL954R2 DESCRIPTION OF WORK: GAS PIPING FROM Mei l at. TO NEW ROOF -TOP UNIT $2,000.00 $88.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: FIXTURE TYPE AND OUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 O Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type O grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 O Medical gas piping (6 +) inlets /outlets 0 0 Gas Pip O Gas piping outlets (0 -5) 1 0 Gas piping outlets (6 +) 0 * *continued on next page ** Phone: Phone: 206 - 763 -1744 Phone: 206 763 -1744 Expiration Date: 01/06/2008 PG07 -305 11/16/2007 05/14/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 PG07 -305 Printed: 11 -16 -2007 Permit Center Authorized Signature: City o'/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us „at ( P-.„.1. Permit Number: PG07 -305 Issue Date: 11/16/2007 Permit Expires On: 05/14/2008 Date: 1 l ` l (4 -0 7 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or thf: perfo ce of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: Date: 1 l doc: UPC -10/06 lily /vv/` -C - This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -305 Printed: 11 -16 -2007 Parcel No.: 2716000060 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12783 GATEWAY DR TUICW GATEWAY CORPORATE CENTER 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. PG07 -305 ISSUED 11/16/2007 11/16/2007 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 * *continued on nest page ** PG07 -305 Printed: 11 -16 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 smii City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: 1\/ / PG07 -305 Printed: 11 -16 -2007 Contact Person: E -Mail Address: CITY OF TUKWIL .) Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:llwww. ci. tukwila. wa. us Name: `!.{,U To 1(✓'e, Mailing Address: 1 1 5 ' K. 1 't(k 54 • Plumbing /Gas Permit No. - GO7— 30 Project No. (For ice us e rnz PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: .1 j (p 00 -- ©o to (� Site Address: 0 $ G 44c (". 4 71 Pt • Suite Number: 1,4 Tenant Name: 644 1 01 fd rtiit Gemit Property Owners Name: Vet 4 / J Cq f� j f (I (j-N V Mailing Address: 12 U 9 De c•► Company Name: fv41( -0{/1 ‘C Gff' M LL(� Mailing Address: 'l'1,7 S' '''`( On 14 Contact Person: \b U "T701 E -Mail Address: Contractor Registration Number: Stir 12-67 4t SN f -z. Q:Upplieations\Porms- Applications On Line\ -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4-2006 bh City New Tenant: W State Floor: ❑ .... Yes ❑ ..No Zip CONTACT PERSON Who do we contact when your permit is ready to be issued Day Telephone: 7-4 3 1 ki City State Zip E -Mail Address: Fax Number: 1' — 76 3' Z 3 'S �( PLUMBING/ GAS PIPING CONTRACTOR INFORMATION -4' d"_ U City State Zip Day Telephone: 1,0U 63 --/14 4 Fax Number: 74)10 Z Ty Expiration Date: \ ' (p ARCHITECT. OF "RECORDS -= All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Company Name: Mailing Address: city Day Telephone: Fax Number: State Zip Page 1 of 2 Fixture Type: Qty : Fixture Type: Qty Fixture Type: .Qty Fixture Type: Qn' Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain 4 / ''77 Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): 945 5 I /P# f' f ' (i(J 07-r k Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R O ' UT i,i, • E I AGENT: Signature: Date: n i l /0 7 Print Name: ' �' 0 ( WI/ Day Telephone: to ( 7 193 -11 H Q: Applications\Forms- Applications On Line l3 -2006 - Plumbing -Gas Piping Permi Application.doc Revised: 4-2006 bh Mailing Address: $ • 4,,y0 C11 , e Cit State Zip Date Application Expires: Date Application Accepted: Staff Initials: Page 2 of 2 Receipt No.: R07 -02534 Initials: WER User ID: 1655 Payee: EVERGREEN REFRIGERATIION TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description GAS - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2716000060 Permit Number: PG07 -305 Address: 12783 GATEWAY DR TUKW Status: PENDING Suite No: Applied Date: 11/16/2007 Applicant: GATEWAY CORPORATE CENTER Issue Date: Amount Payment Check 002792 88.00 Account Code Current Pmts 000/322.100 88.00 Total: $88.00 Payment Amount: $88.00 Payment Date: 11/16/2007 03:48 PM Balance: $0.00 5132 11/19 9710 TOTAL 346.05 doc: Receiot -06 Printed: 11 -16 -2007 COMMENTS: f p/AA - 7r 0* Type of Inspection: - 7 " if f /(- J 1/ / Special Instructions: � 1 Requester: Phone No: ---) J — 7 _, Project: / Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: Requester: Phone No: ---) J — 7 _, -4+) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION c 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Insp or: El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: f�Gd 7 :ads I Project: - 6 14 (-r Type of Inspecn: t -� d (Z,:..,�1i -t Address L ( Date Called: Special Instructions: Date Wanted: L _.a - — /v —Oe -um_ p.m. Requester: Phone No: +1_ INSPECTION RECORD Retain a copy with permit INSPECTION NO. • PERMIT NO. CITY OF TUKWILA BUILDING DIVISION E. f 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: I j lnspect1 j Date: 4 / (t , ' ' a �C 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: IDate: P. 07 -3vs Project: 0/7, Type of //1-774 n; C '9 Address: 7 Y - Pu�: - Date Called: Special Instructions: ...79..._ 3 /73 Dat,Vydpted,! `C / / / �! / "a ,Rj, p.m. Requester: P;z 6 _,.1i7 3. 7 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. El Approved per applicable codes. COMMENTS: A el n /tJo Si 00 REINSPECTIO�REQ tR ED Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: PERMIT NO. © Corrections required prior to approval. License Information License EVERGRL954R2 Licensee Name EVERGREEN REFRIGERATION LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602512953 Ind. Ins. Account Id 42245602 Business Type LIMITED LIABILITY COMPANY Address 1 727 S KENYON ST Address 2 City SEATTLE County KING State WA Zip 98108 Phone 2067631744 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/6/2006 Expiration Date 1/6/2008 Suspend Date Separation Date Parent Company Previous License EVERGI *201D7 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC PARTNER/MEMBER 12/22/2005 PATTON, DAVID PARTNER/MEMBER 01/06/2006 PATTON, RODGER PARTNER/MEMBER 01/06/2006 PATTON, MATTHEW PARTNER/MEMBER 01/06/2006 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information I Bond Bond Company Account Effective Expiration I Cancel Impaired Bond Received https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= EVERGRL954R2 11/16/2007