Loading...
HomeMy WebLinkAboutPermit PG07-318 - WESTFIELD SOUTHCENTER MALL - PANDA EXPRESSPANDA EXPRESS 2600 SOUTHCENTER MALL PG07-3 18 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Cityif Tukwila 6364200010 2600 SOUTHCENTER MALL TUKW PANDA EXPRESS 2600 SOUTHCENTER MALL FC -10 , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA CHARLES LEA 1683 WALNUT GROVE AV , ROSEMEAD CA Contractor: Name: ALOISIO PLUMBING INC Address: 8720 PORTLAND AVE , TACOMA WA Contractor License No: ALOLSPI003KL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT DESCRIPTION OF WORK: INSTALL (2) NEW KITCHEN HOODS, (2) KITCHEN SINKS, (2) HAND SINKS, (1) 50 GALLON ELECTRIC WATER HEATER AND (6) GAS PIPING OUTLETS. Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 $25,000.00 $397.25 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing (cont.) O Building sewer and each trailer park sewer 1 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 O Repair or alteration of water piping and/or water 7 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 O Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 O Medical gas piping (6 +) inlets /outlets 0 5 Gas Piping 0 Gas piping outlets (0 -5) 5 0 Gas piping outlets (6 +) 1 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 626 280 -9188 Phone: 253 537 -9606 Expiration Date: 05/13/2008 PGO7 -318 05/01/2008 10/28/2008 PG07 - 318 Printed: 05-01 -2006 Permit Center Authorized Signature: Print Name: Ii AAS J doc: UPC -10/06 City o`' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO7 -318 Issue Date: 05/01/2008 Permit Expires On: 10/28/2008 Date: I hereby certify that I have read and xanjined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: 1�- � z& __ Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -318 Printed: 05 -01 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2600 SOUTHCENTER MALL TUKW PANDA EXPRESS 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG07 -318 ISSUED 11/28/2007 05/01/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfllled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG07 -318 Printed: 05-01 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: firms rc- doc: Cond -10/06 PG07 -318 Date: s /l /ZD O & ordinances governing or local laws regulating Printed: 05 -01 -2008 Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htV/Iwww.ci.tukwila.wa.us 2(6 a Site Address: . 33 5.sTh &An TG✓ Tenant Name: PANDA i(p/2fSS Property Owners Name: W45/ � _ . Mailing Address: / 1 ( p O 1 w ' / s A i i r � / 3 4 / . v ojth a CONTACT PERSON - - who do we contact when your permit is ready to be issued Contact Person: E -Mail Address: Contractor Registration Number: A i 1J _44! � /aE�Gf 42i3 . ; . c- /04' A m-., al *I1. . /EGA . e CAL Aye, /''R Wok 4/ Grp. Ch -labs C Let in; 14 LAp ..,1e? Q: Applications\Porms- Applications On I3ne13 -2006 - Permit Application.doc Revised: 9.2006 bb At.? -1 .3o Building Permit No. _ - Mechanical Permit - No. " Plumbing/Gas Permit No. Public Works Permit No. Project No. . „Val (For office use only Applications and plans must be complete in order to be accepted for plun review. Applications will not be accepted through the mail or by fax. **Please Print ** King Co Assessor's Tax No. :_tei L , 0( 0 Suite Number: FC —/ Floor: 2 no New Tenant: Q Yes ❑ .. No 471 /Ill City State rgj Lam L S - pay Telephone:_ 4$ 29/ Mailing Address:_ lle.3 AWAVT Ji /tiv57>D e Q / City State Zip E -Mail Address: 1 #J C N� Fax Number:_ 426 4/3a9/07 GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing aid Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: State Expiration Date: ARCHITECT OF RECORD All plans must be wet stamped by Architect of Reco J Rey \. city State Day Telephone: 33o/6 27_ 36,44 Y 704 Fax Number: 3 /Q/ 627 _ 3'4 3 lans must be Wet stamped by Engineer of Record /QOS& MGet L f cA City State Day Telephone:(t ,2 /) 2 0 — Fax Number: ( ( , p / y ) 280— 4 2 Zip Zip 9o4 9 � Zip 4/770 Zip ei/88 6 7/ 8 9 Page 1 of 6 d v Will there be PLANNING Will there be a change in use? BUILDING PERMIT INFORMATION = 206 -431 -3670 Valuation of Project (contractor's bid price): $ /DDl< Scope of Work (please provide detailed information): . or u�t � ra-rosed Yes . new rack storage? DIVISION: 0 145 ,� No If yes a separate � J permit � and plan . mittal will be required. 0q /7 " / TO 54€ 410~7 ,d - j vi e AIi "" Building Areas in Square Footage Below of the foundation of all structures, plus any decks over 18 inches an Floor area of principal dwelling: ere h; 6 B cgc.s- . verhangs greater than 18 inches) Floor area of accessory dwelling: 7' es, ex/d/. 045 _Na /1- in 'rz€ Single family building footprint (are *For an Accessory dwelling, pro ' a e the following :. Lot Area (sq ft): *Provide documents .n that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls ovided: Standard: Compact: Handicap: poem.di ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) . 04 Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes X No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Wpplications\Penns-Applications On Lind a -2006 - Permit Application.doc Revised: 9 -2006 bh Existing Building Valuation: $ No If "yes ", explain: Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty . `Fixture Type: Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets 4 Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 4 ft- Gm4r -- 1 Sinks 4 Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent I Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas `PLUMBING AND GAS PIPING PERMIT INFORMATION - 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ ( oCi2 Valuation of Gas Piping work (contractor's bid price): $ p000 - Scope of Work (please provide detailed information): Dv4 .1i 2 $ et4 KIT-CH Haar .; z 1'-c T 1 71w, 2.. W4VGf W . 1 - . WATT K T . Building Use (per Int'l Building Code): /47b I tt' Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Sewer: Q:Uppliatione\Fomu- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 Date Application Accepted: l t 1 2... $ I e l_ Date Application Expires: 0/ Staff Initials: PERMIT- APPLICATION NOTES Applicable to all permits in this applicatio Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. BUILDING 0 Signature: Print Name: Mailing Address: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. R OR AUTHO ' D AGENT: ,cmi4 �1l dtc4 42.2.3 • # G — /O(o Q: Applications\Forms- Applications On Line13 -2006 - Permit Appliation.doe Revised: 9 -2006 bh Day Telephone: I,? City Date: /V 1.047 3 /o/ AZT— -36'44 x 244 scat e�4 zi p 4: Z Page 6 of 6 Derr.: RECSETS -OR RECEIPT NO: R08 -01441 Initials: JEM User ID: 1165 Payee: WILCOX CONSTRUCTION, INC. SET ID: 0501 SET NAME: PANDA EXPRESS SET TRANSACTIONS: Set Member Amount M07 -256 544.36 PG07 -318 324.00 TOTAL: 868.36 TRANSACTION LIST: Type Method Description Payment Check 073994 868.36 TOTAL: 868.36 ACCOUNT ITEM LIST: Description GAS - NONRES MECHANICAL - NONRES PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT Payment Date: 05/01/2008 Total Payment: 868.36 Amount Account Code Current Pmts 000/322.100 95.00 000/322.100 544.36 000/322.100 229.00 TOTAL: 868.36 1870 05/01 9711 TOTAL 868.36 RECEIPT NO: R07 -02599 Initials: JEM User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us Payee: CAL ARC DESIGN STUDIO, INC. SET ID: S000000903 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -437 800.79 EL07 -723 102.50 M07 -256 128.59 PG07 -318 73.25 TOTAL: 1,105.13 TRANSACTION LIST: Type Method Description Amount Payment Check 833 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Payment Date: 11/28/2007 Total Payment: 1,105.13 1,105.13 1,105.13 Account Code Current Pmts 000.345.832.00.0 102.50 000/345.830 1,002.63 TOTAL: 1,105.13 5432 11/28 9710 TDTAL 1105.13 Project: p , k,/4 Y,tp,i fs Type of Inspection: 6-) F ,,,I I \, Address: 26» re —0 rz i Date Called: Special Instructions: Date Wanted: 7 — r -4 p.m. Requester: L./4 fFjlat Phone No: 13 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ® Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 6,45 r-.0.1 co��rfl< {z 1 rJ ( (F :e,,, I Inspector: INSPECTION RECORD Retain a copy with permit Date: Ft.07-vg PERMIT NO. V (206)431-3 EJ $6 ' . i� REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: �N� �} E p't Type Qflnspectio 1-- / Nr� ? -- (Clo t Address: 0.40 O 1/1P1 A- ( ( Date Called: Special Instructions: Date Wanted: — 2 - — 0� a. Requester: 4 .m Phone No: a- OCo - 817 -13It {2 4o7-3/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: i` I Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Inspector: (Receipt No.: 'Date: COMMENTS: )%'...t . f ,34,,,17, r la .* 1 ° k Address: 200 flAil FC 1 0 Date Called: 6 F ..i, 4 / vl 9 f Date Wanted: a.m. p.m. Requester: gr i vi Phone No: 06 24 a ..- Project: g t. A -e/fte.S5 Type of Inspection: i ltrN(,;. Fr Address: 200 flAil FC 1 0 Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: gr i vi Phone No: 06 24 a ..- I t 127 07-3w INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Va- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Approved per applicable codes. 'Inspector: Corrections required prior to approval. IDate: /— /3"*( El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: / Type of Inspection Address: Gov Pc 0 Date Called: ✓ _. Special Instructions: Date Wanted: 7/II /io a.m.' . p p.m. Requester: . Phone No: I ( INSPECTION RECORD 3, Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION V-- 6300 Southcent Blvd.. #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: y y j/1 fa 5 "me 7 c /D0111 'Inspector: (Date: 7/ p J $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Proj ��t:���//�� 4 e /0 Type of Inspection: t i S /'fpL Address: 2Go Fe- 10 Date Called: Special Instructions: Date Wanted: G_ 7,,,,s,-- ,,, 0 a.m. p.m. Requester: Phone No: Q0G Vii? 0/G INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6,- -3T PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: e (r') Pt eG to en N/A:n L. Tv Rear Inspector: 'Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project:cm Type of In ,pection: r Oos(Ce____ Address: 2600 'WI s4 ( Date Called: Special Instructions: Date Wanted: G_ 5 _ Qti , Alm 157xn. Requester: Phone V 'v (7 " 1 5 I INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Sou thcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 CO Approved per applicable codes. 1 lnspect04 c Corrections required prior to approval. COMMENTS: ac I Date: 6- El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: (--\ i Type &inspection: , re\oNC -1-a•rie— Address: )r)(9 l a i t Date Called: Special Instructions: , Date Wanted: :2 Requester: . Phone No: ( 1 6, • INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 P60 PERMIT NO. (206)431-3670 0 Approved per applicable codes. ID Corrections required prior to approval. COMMENTS: 1d ii 1— /5e.r3rc_ 4 Inspector: Date: El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: COMMENTS: pp yp Inspection: e o f )(9 h - % j }r. �j N [ 1 r V n T {,i Y / /,f S,h (C e I1 t✓ 7 , V&/ .P 14` Date Called: Special Instructions: Gas (i7 'G f•,^ S y ‘c Sf %%d 9a. J eteL Gil. 1I Projec . q NL � CA S yp Inspection: e o f )(9 h - % A res: 6 m ,91/ Date Called: Special Instructions: Date 57— Wanted: _ ° Requester: Phone I mo /� � No: -P,17-7 INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 1 e7 - 3i /2. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Inspector: Date: Ej $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Pro ec Type of nspection Address: c2 70 7YI,1 !, Date Called: Special Instructions: Date Wanted: Requester: Phone No: G4'7.31P INSPECTION RECORD , Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING- VISION - 630 Southcenter Blvd., #1 00; Tukwila; WA 98188 (206)431 -3670 0 Approved per applicable codes. Ei Corrections required prior to approval. COMMENTS: I/,/►_ pillV— e›4<<p7L- Peeir si,1L Pe r lirGi /7"1// MI S�i? 5 S e* 0/1 eV-.e 1 ser v;ce- -fn NA, S /PI CA t( / hir4' I ns pec tor: 6,4 ate * / />r 0 $95�... REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project ' /t,. " Xa/ �S Type of Inspection: %-7 :< /tit' r(' . /e`?i. i, tic` Address:, ..., c- /'79// Date Called: Special Instructions: Date Wanted: J — j a._rj,; p.m. Requester: Phone No: / Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 M Corrections required prior to approval. COMMENTS: /i),S/D,-.-//e/M Date: ,Ze Inspector: $58.O FEE REQUIRED. Prior to inspection, fee must be pa' tudi''at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: l 1 • Project: Type f Inspecti n: , Address: Date Called: Special Instructions: Date Wan ed: Requester: Phone No 0_6(.0 Sr - 7 -(3 3 p6d)-3fe. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit El Approved per applicable codes. jj Corrections required prior to approval. COMMENTS: Ao? Inspectori $58 0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid t 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: ..,„..............•._____ _ . . Project: p ili(14-- Type of lAspectior i ) P1 PiV4 — M../ Addres _ ZWO M RI / Date Called: Special Instructions: Date Wanted: j i /*--) ib A Requester: Phone No: I INSPECTION RECORD I Retain a copy with permit I - W--31 INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION niirhrenter Blvd.. #100 Tukwila, WA 98188 (206)431-3670 El Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspect 2/4A a itivA Ai" 4 .ot ceipt No.: 'Date: 7 ;:otioni - .00 REINSPECTI FEE REM, KED. Prior to inspection, fee must be paid at 6300 Southc ter Blvd.. Suite 100. Call the schedule reinspection. Project P4 /SA' &1 Type of Ipspection: (..I Address: c ,26O0 ril/q// Date Called: Special Instructions: Date Wanted: p.m. Requester: Phone No .2O6-6/7-13/ .4, INSPECTION RECORD Retain a copy with permit / PER NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 [=1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ite.f-cif 2 i_fitp9r6b >4 t ro-s/r1-1 /4 LI $pi10 REINSPECTION FEE to inspection, fee must be id at 6300 Southcenter Blvd.. Suite 1 0. Call the schedule reinspection. r eceipt No.: 'Date: Project: p.0.4 eyp ess Type of Inspection: 6- /3 /j,r,b,-._> Address: 149 I1�i1 Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No 2 VL g/7 /3/G 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 0 e. 1;51- (Inspector: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: 1 PERMIT NO. Til (206)431 -3670 Date: 04 -04 -2008 CHARLES LEA 1683 WALNUT GROVE AV ROSEMEAD CA 91770 RE: Permit Application No. PG07 -318 2600 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 11/28/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 05/26/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 05/26/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall it Technician Permit File No. PG07 -318 City of Tukwila ila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 QERMI1 .J COPY, PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 -318 DATE: 11 - -07 PROJECT NAME: PANDA EXPRESS SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -10 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 1140 Bui •I g i ision Public W 4iQIS ►t. lv i- Complete 17 Comments: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Planning Division ❑ Permit Coordinator n P DUE DATE: 11-29-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route d Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 ❑ No further Review Required DATE: DUE DATE: 12-27-07 Approved with Conditions M Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License ALOISPI003KL Licensee Name ALOISIO PLUMBING INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602033131 Ind. Ins. Account Id Business Type CORPORATION Address 1 8720 PORTLAND AVE Address 2 City TACOMA County PIERCE State WA Zip 98445 Phone 2535379606 Status ACTIVE Specialty 1 PLUMBING Specialty 2 UNUSED Effective Date 5/13/2000 Expiration Date 5/13/2008 Suspend Date Separation Date Parent Company Previous License ALOISPH099KM Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ALOISIO, MARK S 01/01/1980 ALOISIO, NICHOLAS J 01/01/1980 ALOISIO, KIMBERLY A 01/01/1980 Look Up a Contractor, Electrir or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date COLONIAL AM CAS & https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= ALOISPI003KL 05/01/2008 FIXTURE UNIT SCHEDULE ITEM FIXTURE QTY WATER FU SEWER FU EACH TOTAL EACH TOTAL (]D FLOOR DRAIN 6 450 450 2 12 — — ® FLOOR SINK 3,2 110 — 3,1 DEEP FRYER — 110 0 MOP SINK I 3 3 3 3 @ HOSE BIBB I 25 25 32 32 — 3C,D FOOD WARMER 2 1 2 F5 TOTAL — 4B FILTER SYSTEM I 1 I F5 — HAND SINK (COUNTER TOP) I I III 6A 1OF SOO LB IGE MACHINE I I I F5 — 20Q CHINESE RANGE I I I F5 — 20B CHINESE RANGE I 2 2 F5 --- 40A POT SINK I 3 3 F5 41B - VEG. SINK I 3 3 F5 — 3NT) 1 = N. I I I I I TOTAL 21 25 GAS EQUIPMENT SCHEDULE ITEM QTY EQUIPMENT 11°B EACH CFH EACH TOTAL 1 gI "CHINESE RANGE 450 450 450 2°A 20 I 42 "CHINESE RANGE I10 I10 110 2 DEEP FRYER 110 110 220 21D 4E I GOMBIOVEN 12 12 12 I RICE COOKER 32 32 32 TOTAL 154 TEJ2 "GW TO WATER METER FOR CONT. (E)2W G TO SA5 METER FOR CONT. UP (TO LEVEL 3) { (E)soV @ II t-O" 3 4."01^1$ HW %2 "HW DN TO UNDER COUNTER 16 "HW (Li "HW 7 SGALE: 1/4" = I' -D" (a2 GFH) (E) MALL EXI / S. R.VI R. 3 a (32 GFH) 2 7 (E) MALL COMMON AREA WATER 8 6A5 PLAN (E)2 "6 SOV HAI (E)6" 65 DN TO (E) GREASE INTERCEPTOR FOR CONT. o i (E)6 "CO (E)4't &5 UP (TO LEVEL 3) P.O. 2 "V 1 . ioli NS No changes shall be o P to th of P of work without pt� approval Tukwila Buildiing Division. NOTE: Revisions will require a new nlan submittal :r•,ri ., w Include additicrat plan re1/!w fees (E)4 "GS 3 "GS,2 "V I' EXIT/ SERVICE 2 "V SCALE: 1/4" = I'-O" (E)3 "V 1 I (E "V (E) MALL EXIT/ SERVICE CORR. City of TAM* BUILDING DIVfSION 2 "GS,2 "V (E) MALL COMMON AREA FILE COPY s� Penult Pion review appraly d eutfoottt mos and wisdom Approval scans tmcdan documents doss nai the violallonat any ado �a A pt of-p Reid Copy and Date s /i /00c WASTE 8 VENT PLAN (E )3"V ,2 "V m # 2"V 1 SEPA A TE PERMIT REQ IRED FOR 4 echanical E ❑ l ❑ s Piping 1 City cif Tukwila cS I! Dill DIVISION cope cot* tACE APIMO PLUMBING PLAN NOTES 0 ELEC. WATER HEATER, SEE DETAIL #I2 ON DWG P -4.0 12] "GAS DOWN TO RICE COOKER W/ SOV. (32 GFH) © I" GAS DOWN TO ROAST OVEN W/ SOV. (012 GFH) ® 1" GAS DOWN TO DEEP FRYER IN SOV. (110 GFH) EA. © 1 GAS DOWN TO CHINESE RANGE W/ SOV. (450 GFH) ® I%" GAS DOWN TO CHINESE RANGE W/ SOV. (MO GFH) 0 ROUTE NEW PIPING IN EXISTING WALL. REPAIR AND PATCH WALL PER ARCHITECTURAL REQUIREMENTS. ® SODA CONDUIT: PROVIDE PVG CONDUIT UP TO ABOVE CEILING FROM SODA STORAGE TO SODA DISPENSER. PER DETAIL #I, ON DWG P -4.0 O CONDENSATE: PROVIDE I" INSULATED CONDENSATE DRAIN PIPE FROM THE EVAPORATIVE COIL IN THE COOLER REFER TO "WALK IN GOOLER/FREF7ER" DETAIL #3 ON DWG P -4.O DISGHARSE TO FLOOR SINK WITH AIR GAP OF TWICE PIPE DIAMETER. R P4 RELIEF: PROVIDE 3/4" Pa PIPE CONTINUE AND STOP AT 6" ABOVE MOP SINK. j PROVIDE TRAP PRIMER FOR FLOOR DRAIN , SEE DETAIL #Il ON DWG P-4.0 © PROVIDE LOCKABLE SHUT -OFF VALVE $ SPACE FOR WATER METER IN UTILITY CORRIDOR. NOTE FOR ADDITIONAL NOTES AND PLUMBING FIXTURE SCHEDULE, SEE DRAWING P -2.O RECEIVED CITY OF TWW1114 NOV 2 s 2007 5N Hi'G CONSULTING ENGINEERS, In 556 N. Diamond Bar Blvd., #304 Diamond Bar, Galifornia g1765 Tel Fax :( -816G• E- ma1I:HYG ©HYGENGINEER.GOM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.7ac.a &aS Facsimile: S26372.828S All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 1ST 1ST SUBMIT DRAWN BY: PANDA PROJECT #: M1-08-D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD. CA 91770 TEL 626280.9188 FAX: 626.280.9189 E -MAIL: INFO@CALARC.NET EXPIRES 515/ O 1 7 S.C. PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 P -1.0 PLUMBING WATER/GAS/ WASTE & VENT FLOOR PLAN Z:1Cat Are ProJeoh07 ProJed.CAL Arcl97 -1 PX conostructIon doeiment\170705 PX 0 South Center Mall, Tukodlo, WA M1 -0&0718s MEP 0Ny(amItA17075SfiVirC1cPC0719 PLUMAyeg, 11/13/2007 8:45:45 PM, ace TDS4001s.pc FIXTURE BRANCH SCHEDULE FIXTURE GOLD 1 ThR HOT y TER WASTE VENT 2 AND 3 - COMP SINK 3/4" 3/4" 3" 2" HAND SINK 1/2" 1/2" 2" 11/2" MOP SINK (J.S.) 3/4" 3/4" 3" 2" EQUIPMENT 1/2" -- -- -- FLOOR DRAIWSINK -- -- 3" 2" 36.'7 6h 74 F.U. @ psi 23 F.U. © psi PIPE MATERIAL SCHEDULE SERVICE UNDERGROUND ABOVE GROUND GOLD HOT WATER HARD DRAWNGOPPER TUBE " � HARD DRAWN COPPER TUBE SANITARY WASTE " " � NO -HUH OAST IRON, ABS �� NO -HUB GAST IRO/ ABS SANITARY VENT "NO -HUB" GAST IRON, ABS * ST L, 40/ "ON/ ABS A * IROW "NO-NO -H UB" OAST R . GAS 8 F.U. @ BLAGK STEEL, SGHEDULE 40 F.U. @ psi INDIREGT DRAIN 13.4 HARD DRAWN COPPER TUBE TYPE "M" IG F.U. @ psi F.U. © psi 114' WATER PIPE SIZING CHART (GOLD WATER) PIPE SIZE GPI i VELOCITY FT /SEG FIXTURE UNITS F - TANK F - VALVE 1/2" 25 35 2 F.U. @ 6 0 psi F.U. © psi 3/4" 6.6 4.4 8 F.U. @ psi F.U. @ psi I" 13.4 5.2 IG F.U. @ psi F.U. © psi 114' 23.3 5.Q 37 F.U. @ psi 6 F.U. @ psi 1 14" 36.'7 6h 74 F.U. @ psi 23 F.U. © psi 2" 76.4 7.'1 254 F.U. @ y psi 132 F.U. @ psi WATER PIPE SIZING CHART (HOT WATER) PIPE 5I ZE GPM VELOCITY FT /SEG FIXTURE UNITS F - TANK F - VALVE 1/2" 25 35 2 F.U. @ 6.0 psi F.U. @ psi 3/4" 6h 4.4 8 F.U. @ psi F.U. @ psi I" 13.2 5.0 I 1 F.U. @ psi F.U. © psi 1 4' Ig.O 5.0 37 F.U. @ psi 6 F.U. @ psi GENERAL PLUMBING NOTES A. LANDLORD: Meet Landlord's Tenant Griteria w/ regard to construction features special requirements, etc. verify when $ how work may be performed in other spaces, where required. B. FOOD SERVICE EQUIPMENT: Refer to other portions of Plans c$ Specifications for further information about food service items furnished $ work performed by others. Verify rough -in requirements w/ equipment furnished. G. HEALTH DEPARTMENT: Comply w/ local Health Department (HD) regulations. Omit escutcheons in food service areas. Seal pipes neatly w/ grout at wall, floor, or ceiling penetrations. Omit insulation on exposed piping behind $ under equipment. Provide clearance for cleaning behind $ under exposed piping as required by HD. Wherever possible, install all piping concealed. Conform to HD requirements for locations of floor sinks. D. WORKMANSHIP shall be first class, acceptable to the Tenant $ Landlord. E. MAKE COMPLETE: Provide items $ work as required to complete the installation of plumbing systems to fixtures ' equipment: traps, strainers, gauges, gas $ water pressure regulators, flexible connections, stop valves, unions, etcetera. Provide $ connect plumbing pipe from rough -ins to items as shown, specified $ required. F. VERIFY LOCATIONS: Existing piping, POG shown on Drawings has been located from information provided by others. Verify exact locations on job site before start working. S. BAGKFLOW PREVENTION: Provide backflow preventers (BFP) in water lines only if required by local authorities. Use devices of type (vacuum breaker, double check, reduced pressure) $ manufacturer approved by local authorities, only in locations required. (existing water supply has a B.F.P.A. installed) H. TRAP PRIMERS: Provide trap primersjEW re uired by local authorities. Use Precision Plumbing Products or approve equivalent trap pimer valve, installed in an exposed but unobjectionable location, or above the ceiling. Provide a continouous length of 1/2" soft copper tube from primer to trap, sloping to trap. Provide elastomeric insulation on pipe installed below floor slab. Use Precision Plumbing Products distribution units to connect more than one floor sink to one primer. I. WATER CONSERVATION: Contractor shall provide water flow limiting features on fixtures if /as required by local authorities. J. GOLD WATER: Connect to domestic cold water valved stub provided by Landlord in this vicinity above ceiling. Extend cold water pipe, suspended from structure above ceiling 4 down in partitions, to serve fixtures 4 equipment. (field verify) K. HOT WATER: Provide 50 gallons storage tank type commercial water heater. Run hot water pipe, suspended from structure above ceiling $ down in partitions to serve fixture c$ L. SANITARY: Connect to sanitary waste line provided by Landlord below floor. M. BRANGHES: Provide hot and /or cold water pi es don in partition to serve various equipment per "Kitchen Equipment Schedule ". N. SODA GONDUIT: Provide conduit below floor from soda storage to soda dispenser. 0. GONDENSATE: Provide I" insulated primary $ secondary condensate drain pipes from fan -coil unit above ceiling , It's termination to nearest floor sink. P. GUT AND PATCH existing wall or partition as required to install new plumbing piping. Q. GAS SERVICE: Gonnect to 2" pipe provided by Landlord for natural gas service to this shop. Coordinate w/ gas utility company for meter requirements, permits $ fees. Route pipe as required, suspended from structure above. Use all welded pipe, fittings ' joints in ceiling space in wa ll. PLUMBING FiXTURE SCHEDULE Items in this schedule or their approved equivalent are furnished and installed by the Plumbing Gontractor. `D> FLOOR DRAIN: Zurn * 415 -13 cast iron drain with 5" round nickel bronze top, membrane flashing clamp. Provide 2" outlet with P -trap. Glean and polish after installation. Refer to detail. PROVIDE TRAP PRIMER FLOOR SINK: Zurn # ZN -I q00- 4- 33 -KG, cast iron body acid- resisting enameled interior, seepage pan, 12" square top with porcelain enamel loose -set grate with center hole; aluminum anti - splash interior dome strainer, outlet size as required. Refer to detail. MOP SINK: Fiat #MSS -2424 24 "x24" molded stone ulnit with minimum 10" high sides, stainless steel drain body internally cast; Chicago Faucet #Sq7 with integral stops in shanks, wall brace, hose threads, pail hook, vacuum breaker; Rough brass finish; Three foot rubber hose; 2" trapped and vented waste connection. Provide 3/4" HW $ GW RI 8' oc, 36" a.f.f. ELEG. WATER HEATER: "AMERICA" MODEL: LDGE5OD GOMMERIAL 50 SLA., 4.5 KW, 40SV 3 (P, 20.7 GPH, RECOVERY @ q0 °F RISE. WATER HAMMER ARRESTER: J. R. Smith *5020,1" nipple or equal PROVIDE STAINLESS STEEL PRESSURE REDUCE BAGKFLOW PREVENTOR AT DRINKING DISPENSER. HOSE .BIBS: Acorn #8121 with vacuum breaker, polished chrome plated. TRENCH DRAIN: ZURN #Z- 664 -AR, 6" Wide top modular trench drain, Dura- Goated cast iron drain section with bottom outlet and seconday dome strainer. Both 12" long grain module and 12" long extension module are complete with integral seepage pan and loose extra heavy duty slotted grate. * ABS GAN BE USED IF SHELL BUILDING SEWER VENT PIPES ARE ABS. MUST BE APPROVED BY LOCAL GODES. KITCHEN EQUIPMENT SCHEDULE WARMINS TABLES: Provide 1/2" FIN RI at 20" a.f.f. for each 3D section with BV. Provide I" IN valved heaser to FS, with 1/2" connections to pan drains. Provide 1/2" HW RI at 24" a.f.f. SODA MAGHINE: Provide 3/4" IN from ice bin to FS. Items in this schedule are furnished by the Owner $ installed by the Contractor $ connected to the plumbing utilities by the Plumbing Contractor (PG). PG shall install plumbing devices furnished w/ equipment. AFF =Above finished floor, OG =On Center, HW =Hot Water, GIN =Gold Water, RI =Rough -In, E3V= Ball Valve (full port), AS -Angle Stop (chrome-plated, wheel- handle), ID= Indirect Drain. FS =Floor Sink, VB= Vacuum Breaker. Where "FLEX" is called for, provide a six foot coiled length of flexible reinforced plastic tubing from the RI to the equipment, using adapters $ hose clamps as required. CARBONATOR: Provide 1/2" GW RI 86" a.f.f. w/ BV and reduced pressure type of stainless steel and connect to equipment as required. make connection from BV to GARBONATOR with Watts #qBD and Watts oodlSS backflow preyenter. Install owner furnished water filter system. WATER FILTER: Provide 1/2" GW RI 12" a.f.f. with BV and connect to equipment as required. Provide elbows where risers connect to faucet behind backsplash. Provide 11/2" vented waste RI in wall 24-1/2" a.f.f. Provide I 1/2" chrome-plated semi -cast brass P -trap with cleanout and waste arm to wall. IGE MACHINE, AIR COOLED: Provide 1/2" GW RI 50" a.f.f. Provide BV and Watts #288A VB and flex. Provide ID from bin, Guber, Condensate to FS. See IGE MAGHINE connection detail on sheet P -4.0 CHINESE RANGE: Provide 1/2" CIA( with Zurn #128 pressure type vacuum breaker. RI 12" above equipment connection. Floor rim, with V. Provide 1%" gas stub 10" a.f.f. with shutoff cock. connect wataer to faucet and gas to burner 10" a.f.f. Provide 2" ID to FS (450 GFH). Provide 25 GPM flow control fitting. install owner supplied gas regulator GHINESE RANGE: Provide 1/2" GIN with Zurn #728 pressure type vacuum breaker. RI 12" above equipment connection. Floor rim, with V. Provide I" gas stub 10" a.f.f. with shutoff cock. connect wataer to faucet and gas to burner 10" a.f.f. Provide 2" ID to FS (MO GFH). Provide 25 GPM flow control fitting. install owner supplied gas regulator FRYER: Provide 5 /4" gas cock, 14" a.f.f. for each of two fryers, Connect to burners w/ flexible metal gas connectors furnished by FSEG. (Total of 110 GFH) install owner supplied 3 4" gas quick disconnectors COMB' OVEN: Provide I" gas cock on header, 30" a.f.f. connect to burner as required (q2 GFH) install owner supplied gas regulator, solid piping Provide 1/2" GW RI 30" $ W/Backflow Proventor " WATT" i2" NO OOq , AND Provide IN from BIN, RICE COOKER: Provide 1/2" gas cock, 30" a.f.f.. Gonnect to burner with flex connector furnished by FSEC. (32 GFH) install owner supplied %2" gas quick disconnector. WALK -IN COOLER: Provide I" IN from DX evaporator coil to discharge over floor sink. Refer to detail. POT SINK: Provide 3/4" WI GW RI 8" OG 14" a.f.f. Provide BV's and extend copper piping to faucet. see "Utility Sink" detail for waste piping. Provide 2" copper piping to each compartment. connect to grease waste. Provide 25 GPM flow control fitting, VEGETABLE SINK:Provide 3/4" HW $ GW RI 14" a.f.f. 8" OG. Provide BV's and extend copper piping to faucet. Manifold 2" waste lines from two compartments together and discharge into floor sink with air gap. Use copper pipe, fitting, and connectors, see "Vegetable Sink" detail for waste piping. HAND SINK, WALL MOUNTED: Provide 1/2" FIN and GW RI S" OG 24" a.f.f. Provide AS and chrome - plated risers to faucet. Provide elbows where risers connect to faucet behind backsplash. Provide 11/2" vented waste RI in wall 24 --1/2 " a.f.f. Provide I 1/2" chrome - plated semi -cast brass,.. V - c e\ P -trap with Gleanout and waste arm to wall. n -I� p D17 PLUMBING SYMBOLS TW F G FV — --Q 5 -- J 1 VTR AFF /AFC GO INGO FGO FSGO FD FPG DNR TYP (E) BV COLD WATER PIPING HOT WATER PIPING TEMPERED WATER AT 110' FILTERED WATER GAS LINE PLUMBING VENT (V) PLUMBING VENT (V� BELOW SLAB /GRAD SANITARY WASTE (SAN) BELOW SLAB /GRADE EXISTING SANITARY BELOW SLAB /GRADE WASTE (SAN) PIPE TURNING UP /DOWN GAS COCK F.S. WITH HALF GRATE FLOOR DRAIN FIXTURE I DENT F I GATI ON PLAN NOTE KITGHEN EQUIPMENT IDENTIFIGATION VENT THRU ROOF ABOVE FINISHED FLLR /GRADE GLEANOUT WALL GLEANOUT FLUSH FLOOR/GRADE GLEANOUT FLOOR DRAIN FIRE PROTECTION GONTRAGTOR DEPARTMENT OF NATURAL RESOURCES TYP I GAL EXISTING POINT OF CONNECTION BALL VALVE FIXTURE UNIT SUMMARY SERVICE DOMESTIC WATER SANITARY SEWER OLD F.U. 0 0 SERVICE REQUIREMENTS SERVICE DOMESTIG WATER SANITARY SEWER FUEL GAS FIRE PROTECTION NEW F.U. 21 2S SIZE MAIN (E)2 I NGH (E)4 I NGH (E)2 I NCH I NCH TOTAL F.U. 21 2S GAPAGI TY 15 GPM 28 F.U. '484 GFH GPM * 13AGKFLOW PREVENTER MODEL: EXISTING SIZE N/A ** PRESSURE REGULATING VALVE MODEL: WA SIZE WA SECE1VE0 crrvCJFTT3KW1LA NOV 2 8 2001 iii HYG CONSULTING ENGINEERS, Inc. 556 N. Diamond Bar Blvd., #304 Diamond Sr, a Gallfornla 81765 TI : (QOg)3g6 -8168 • Fax: (gog)3g6 -8I6q • E-ma 1 I : HYG@ HYGENG I NEER.GOM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.7Gci.cleAS FOGS imi le: 626.312.S2SS All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 1ST 1ST SUBMIT DRAWN BY: ARCHITECT : 1683 WALNUT GROVE AVE, SUITE #301 ROSEMEAD, CA 91770 TEL: 626.280.9188 FAX: 626280.9189 E-MAIL INFO@CALARC.NET P -2.0 PLUMBING NOTES AND SPECIFICATION S.C. PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 =al Are Project Project-CAL Arc107 -1 PX conc 5uctlon documen"170705 PX South Ceder Mall, Tukwila, WA M1A8-a1189 MEP Only(0m4)11717705R1\HYCICPC0719 PUJM.d4g, 11/13!!007 6:49:17 PM, Oce TDSS4001xpr3 2"65,2"V 0 3 /4 "GW 5 4"0^141 - 41A1 4"65 1-i 2 "SS- 1 "GW (E)6 "G5 DN TO (E)GREASE INTERCEPTOR \\ ` (E)6" GS P h WATER RISER DIAGRAM 2 "V I� `\ 4"65 y r-- I I �� 2 "V I � \_ .� • �` I 2 „ I T` � : r � � I 2"65,2"V I �� �. n I I 1 �� V \ .l ) 3 GS I 3"65,2 "V r I E 2 "65,2 "Y 2 "G O I SnGS_� /{4"05 ICI ' — 0 N 2 " e5, 2"∎� ` I / L 2 "FV -• 1/ ` 3" 2"V / 3 "V 3"GN. 2 "GS,2 "V ■ • ` 2 "V L ck I1 3 "65 0 2FV./- 1 2 „ 6S �„ V / 1 V \ 2"FV 4"e5 ' 1 \� (E)6" GS 2 "GS,2 "V I "GW4 I "HIN I! "GW4 I "HW WASTE AND VENT RISER DIAGRAM 3 "GS,2 "V n 418 I1 "GW 3 4 "GW41 -1W P.O.G. 2 "GS,2 "V (E)2 "GY`1 011 A.F.F. CEILING (E)2 "GW (E)3 "V GAS RISER DIAGRAM I 1.," G (450 GFH) 10' 1 " G 1 "G 2 "G (110 GFH) (I10 GFH) (140 GFH) (E)2l" G TO (E)GAS METER FOR GONT. P.O.G. ANSUL VALVE 2"56560 GFH) ANSUL VALVE 114."5(124 GFH) 25' 5' �\ 2 "G \` 2 "G 2 "G 1 " G (42 GFH) \ (E)21 "G (32 GFH) 10' (E)2 "G 1 REVEEWE A CODE COMPLIANCF APPROVED Oty Of Tukwila . 1 GEILING Nav 282 1 HYC CONSULTING ENGINEERS, Inc. 556 N. Diamond Bar Blvd., #304 Diamond 13ar, Gallfornia 11765 TeI:(904)3c16- -8168• Fax:(gOR)3G6- 816 E-mal1:HYG@HYGENGINEER.GOM PANDA RESTAURANT GROUP INC. 11683 Walnut Grove Ave. Rosemead, California 91770 ,Te Iephone: 626.7 Fac�lmile: 526.372. 2SS All ideas, designs, arrangement and plans indicated or represented by this drawing ore the property of Panda Express Inc. and were created for use on this specific project. None of these ideas. designs, arrangements or plans may be used by or disclosed to any 'person, firm, or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 15T 1ST SUBMIT 2ND DRAWN BY: PANDA PROJECT #: M1-08-D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUfTE #301 ROSEMEAD, CA91770 TEL: 826.280.9188 FAX: 626.280.9189 E MAIL INFO @CALARC.NET EXPIRES 515/() e S.C. PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 P -3.0 WATER/GAS/WASTE & VENT RISERS 7.,rd n.,.a am aj e«.,n- . ........e ..r.. ,.._,a.. ••.•■..•..... •... ....�.. FIXTURE UNIT TABULATION FIXTURE GOLD HOT VALVE HATER CLOSET 10 -- TANK WATER CLOSET 5 -- URINAL 5 -- L.AVATORY /SINK 1.5 1.5 JANITOR'S SINK 3 3 SHOWER/BATHTUB 2 2 POI SIZE PIPE SIZE FIXTURE UNIT LOAD A - 1/2" I -ll B 3/4" 12 -32 G I" 53 -60 D 1 -1/4" 6I -113 E I -1/2" 114 -154 F 2" 154 -330 PLUMBING SPECIFICATIONS I. THE WORK includes connection of plumbing utilities to Landlord's utilities and installation of a complete plumbing system within the shop. Provide new materials, fittings, accessories, fixtures and equipment necessary for a complete and properly functioning system as shown on the plans and as required. The work includes final connections to equipment and fixtures provided by others. Furnish all new materials. Work shall be performed by experienced tradesmen, and their workmanship shall be high standard, acceptable to the Architect, Tenant, and Landlord. 2. CODES: All work shall be In accordance with local codes, safety regulations, or ordinances. Pay for any permits required, and call for any required inspections to be made by local authorities. 3. THE INTENT of the drawings is to indicate the eneral extent of the work required for the project. The drawings for plumbing work are diagrammatic, showing the general location, type, piping, fixtures and equipment required. Provide all fittings, accessories, offsets, and materials necessary to fulfill the intent of the Plans. The drawings shall not be scaled for exact measurements - use dimensioned Architectural drawings. Refer to manufacturer's standard rough -in drawings for plumbing fixtures, and to Architectural drawings for exact locations. 4. FSE ROUGH -IN DRAWINGS: Refer to rough -in drawings furnished by the Food Service Equipment supplier, for exact location of water piping supplies and drain locations to serve Food Service Equipment. Do not layout the work of this Section without such drawings. 5. COORDINATE with the work of other sections and trades, with equipment furnished by others, and with the constraints of the existing conditions of the project site. 6. MISCELLANEOUS EXPENSES such as hook -up charges, permits, inspections, and other expenses related to a complete and functioning system are included as part of this Section. "1. PIPING SYSTEMS, GENERAL: All piping shall be run parallel to building lines and supported and anchored as required to facilitate expansion and contraction. All piping shall be concealed except in unfinished spaces. Install as required to meet all construction conditions and to allow for installation of other work Including ducts and electrical conduit. At all connections between ferrous piping and nonferrous piping, provide an isolating dielectric union. Seal pipe penetrations of fire floors andfirewalls with fireproof putty or grout. Provide Sumner or equivalent pipe hanging system In chases. Provide hangers as recommended by hanger manufacturer and MSS- SP -58, 6W and 8g. S. WASTE PIPING: Provide all drain, waste and sewer piping within the project space with connection to the Landlord's sanitary waste sys on site. All piping below floor slab shall be service weight hub and spigot pipe and fittings with neoprene gasket joints, or hubless pipe with cast iron couplings with stainless steel bolts coated with mastic. All waste piping above floor shall be service weight copper hubless pipe, connectors and fittings. All piping shall be sloped uniformly at 2% unless otherwise required by existing conditions. ci. VENTS: Provide a complete system of vent piping, consisting of service weight cast Iron hubless pipe, connectors and fittings. Combine the vent risers in the ceiling space and connect to existing vent main provided by Landlord. 10. WATER PIPING: Connect to existing water piping and provide a new domestic hot and cold water piping system inside the building as shown on drawings. Lay out water piping so that entire system can be drained. Hot and cold water piping shall be Type "L" copper tubing ASTM B-SS with wrought copper fittings and sweat connections using lead -free solder. Provide water hammer arresters at contractor's option. Flush the water piping clear of debris and clean the aerators and strainers at the termination of the installation. II. NATURAL GAS PIPING inside and outside the building above grade shall be Schedule 40 black steel ASTM A -33 pipe with 125 lb malleable iron screwed fittings where exposed, and welded fittings and Joints where concealed. Primer and paint exterior gas piping to prevent rust. Provide all unions, shut off valves and drip legs required by NFPA -54 and governing codes. Provide all tests, inspections, hangers and appurtenances required for a complete and operating system. Tap on utility gas main and gas meter shall be by gas company. Extend piping from meter to equipment as detailed on drawings. Provide routing, hanging, and penetrations per Landlord's requirements. 12. PIPE INSULATION: Insulate all cold water and condensate piping with I /2 ", and hot water piping with I ", preformed fiberglass with all- service Jacket with vapor barrier (by GT, OG, JM, PPG, or Knauf). At contractor's option, plenum -rated elastomeric insulation (by Armstrong, Rubatex or equal) may be used. 13. SHUT -OFF VALVES with unions shall be provided at branches to groups of more than two fixtures, and at the water heater, to facilitate isolation for repair or replacement. Use chrome - finished forged bronze body ball valve, with teflon seats and packing, 400 lb WOG, with solder ends, equal to Jenkins i02 -T. Gas valves shall be all bronze lubricated plug cocks for screwed pipe, by Walworth, Rockwell, Nordstrom or approved equivalent. 14. ACCESS PANELS shall be provided in ceilings or walls where concealed control devices are located, except where access for adjustment and maintenance is possible through lay -In ceilings. 15. SUPPLIES AND TRAPS: Rrovide water sealed traps and supplies installed as close as possible to all plumbing fixtures, drains, and food service equipment or beverage dispensing equipment items furnished by others, having a waste connection, or requiring water service. Exposed traps and supplies in exposed areas (including cabinet interiors) shall be chrome plated brass. 16. INSTALLATION: Thoroughly clean items before installation. Gap pipe openings to exclude dirt until fixtures are installed and final connections have been made. Proceed as rapidly as construction will permit. Set fixtures level and in proper alignment. Install supplies in proper alignment with fixtures, per manufacturer's rough -in dimensions. Install silicone sealant between fixtures and adjacent material, for sanitary joint. Repair any damage clone to existing features and restore to original conditions. Provide clean conditions at termination of work. 17. TEST water, gas, vent, and waste systems per local code requirements. When testing indicates materials or workmanship are deficient, replace or repair as required, and repeat test till standards are achieved. 18. GUARANTEE the work and the installation for one year after formal acceptance by the Landlord and Tenant. H. ALL saw cut and patch back of floor to match existing finishes. Backfill per landlord' soils engineer's recommendations TRAP PRIMER OVERHEAD G.W. SUPPLY ... .. rrrirr r. r A UNIO ZZ VACUUM BREAKER FINISH FLOOR NG.W. SUPPLY GRAVITY LiNE TO TRAP TYPICAL TRAP PRIMER DETAIL NOT TO SCALE 17 ROOF CEILING SINGLE FI)CTURE ROOF PENETRATI j� GAS PIPE ON ROOF PER DETAIL -1 \41 . SUPPORTED PER DETAIL DO NOT INSTALL VALVES B ALL. GAS PIPING FROM THIS IN CEILING SPACE POINT INTO SPACE IS TO BE WELDED JOINTS ONLY EXHAUST HOOD MANUAL GAS VALVE (TYP) 32 "ID a FLEXIBLE APPLIANCE CONNECTOR FURNISHED BY OTHERS. STUB OUT IN/ MANUAL VALVE AND CAULK AROUND GAS PIPE WATERTIGHT TYPICAL 6" DIRT LEG FLOOR -�- u u TO 6" ABOVE FLOOR ARRANGEMENT SHOWN IS SCHEMATIC. MAKE FINAL CONNECTION TO EQUIPMENT AS RECOMMENDED BY MFGR PROVIDE WELDED FITTINGS $ JOINTS IN ANY CONCEALED, UNSLEEVED LOCATION. CONFORM TO REQURRMENTS IN NFPA 54 AND LOCAL GORES /AUTHORITIES. GAS SYSTEM TO BE TESTED WITH A TEST PRESSURE OF NO LESS THAN 1 TIMES THE PROPOSED MAXIMUM WORKING PRESSURE (NOT LESS THAN 3 PSIG), FOR A DURATION OF NOT LESS THAN 14 HOUR FOR EACH 500 CUBIC FEET OF PIPE VOLUME OR FRACTION THEREOF. REFER TO NFPA 54 FOR FURTHER TESTING INFORMATION. COOKING APPLIANCE GAS PIPE PROVIDE CLEANOUTS IN TURNS/ENDS OF PIPE. USE DM/ FITTINGS IF SIZE IS LARGER THAN 1 ". SLOPE PIPE AS MUCH AS POSSIBLE TOWARD DISCHARGE. -�' /d ff ST IN AL L PER PD I PDI STANDARDS AND SIZE MANUFACTURER'S "A" INSTRUCTIONS. METER THE INSUL ATION AT ELBOWS AND E.OWS 50 THAT THERE ARE NO GAPS AT JOINTS IF POSSIBLE, THEN TAPE THEM. OTHERWISE FiLL THE GAPS WiTH BLANKET FIBER- GLASS AND PROVIDE ONE -PIECE PRE - MOULDED PVC FITTING COVERS. MAKE CONNECTION TO EQUIPMENT AS REQUIRED. MAKE PIPE MINIMUM ONE SIZE LARGER THAN EQUIPMENT CON- NECTION, MINIMUM 3/4 ". USE "M" OR "L" HARD COPPER UP TO I" AND TYPE PINY FOR LARGER. - ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPE AS REQUIRED. DO NOT INSULATE INDIRECT DRAIN PIPE WHEN INSTALLED IN FOOD SERVICE FACILITY. REFER TO LOCAL CODES FOR FURTHER INFORMATION. INDIRECT DRAIN IF HORIZONTAL BRANCH IS LESS THAN 20' LONG, PROVIDE ONE INHA AT END OF LINE. IF BRANCH iS GREATER THAN 20' LONG, PROVIDE ANOTHER 111-IA IN MIDDLE, EACH SIZED FOR HALF THE FIXTURE UNITS. o ' DO NOT PROVIDE AIR CHAMBERS. PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND O -RING CONSTRUCTION, HAVING PDI #WH- 201, ASSE # 1010 AND ANSI # AI12.26.IM CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND /OR PER THE TABLES SHOWN ABOVE. WATER HAMMER ARRESTERS NOT TO SCALE COVER VALVE BODIES WITH INSULATION, BUT NOT UNIONS. / _, ‘ArNPr al 1111%. ■ ` in ■L PROVIDE 1/2" UNICELLULAR ELASTOMERIC INSULATION ON DOMESTIC HOT AND COLD WATER PIPES IN WALLS AND CHASES MITER THE INSULATION AT TEES AND EL- BOWS. SEAL ALL JOINTS WITH ADHESIVE. +' �' - PROVIDE 1/2" FIBERGLASS INSULATION WITH ALL- SERVICE JACKET WITH VAPOR BARRIER ON ALL COLD WATER, CONDENSATE, AND STORM DRAIN PIPE UP TO 4". PROVIDE I" INSULATION ON STORM DRAIN PiPE ABOVE 4 SIZE. PROVIDE I" FIBER- - GLASS INSULATION WITH ALL - SERVICE JACKET ON DOMESTIC HOT WATER PIPING. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION. INSTALL ALL ITEMS PER SPECIFICATIONS AND MANUFACTURER'S INSTRUCTIONS. MAINTAIN VAPOR BARRIER ON GOLD PIPING BY MEANS OF SEALANT AND TAPE. FLAME - SPREAD AND SMOKE- DEVELOPED INDEXES SHALL NOT EXCEED 25/50. SEAL EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC. °. GAS VALVE (TYP) PC TO ROUTE GAS PIPING IN PARTITION WALL AS RECD WITHOUT JOINTS. STUB OUT PIPING JUST BELOW CEILING TO EXPOSE VALVES THEN ROUTE PIPING BACK INTO WALL SPACE. SEAL ALL WALL PENETRATIONS IN/ CAULK. NOT TO SCALE DISCHARGE INTO CENTER HOLE OF GRATE OF FLOOR SINK WITH AIR GAP SUFFIC- FIGIENT TO REMOVE GRATE AND STRAINER. MINIMUM GAP = TWICE PIPE DIAMETER. PROVIDE TRAP AND 6" HIGH PIPE VENT OPEN TO ATMOSPHERE WHEN DRAIN LINE IS LONGER THAN 5' (IAPMO) OR 2' (BOCA). NOT TO SCALE HOT OR GOLD WATER SUPPLY MULTiPJ B FIXTURFS PIPE INSULATION NOT TO SCALE \_ TAPE JOINTS OF Fl- BERGLASS INSULATIO PROVIDE A ONE FOOT LENGTH OF NONGOMPRES- SIBLE INSULATION AT HANGERS FOR ALL PIPE 2" AND LARGER. REFER TO OTHER DETAILS FOR TREATMENT OF INSU- LATION AT PENETRATION OF WALLS, FIREFLOORS, FLOORS, AND FIRE! iALLS. 1/4" HOLES 014 3/4" CENTERS \ FOR VENTILATION PLYWOOD ROOF RAFTERS TYPE "5" DOUBLE WALL FLUE / "WATTS" 1/2" NO. OOa REDUCED PRESSURE PRINCIPLE ASSEMBLY. ABOVE BALL VALVE MINIMUM 6" ABOVE ICE MACHINE, MOUNTED ON PIPE ICE MACHINE CONNECTIONS PROVIDE FULL PORT BALL SHUT -OFF VALVE ON ROUGH -IN. INSTALL WATER FILTER PER MAN- UFACTURER'S INSTRUCTIONS IF FURNISHED WITH ICE MACH. INSTALL WHERE AGGES5115LE. FLOOR - 2„ FS �r PROVIDE FLOOR SINK AT FRONT EDGE OR SIDE EDGE OF ICE MACHINE, WHERE ACCESSIBLE FOR I" CLEANING - NOT UNDER ANY EQUIPMENT. PROVIDE GOLD WATER ROUGH -IN AT TOP OF ICE MACHINE. ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO SUIT CONDITIONS. VERIFY CONNECTIONS WITH MANUFACTURER. PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "GO" GAST IN COVER. PROVIDE GLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE PLASTIC PLUG IN CAST IRON BODY: CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. \FLOOR SLAB ON GRADE MEMBRANE CLAMP AS REQUIRED FOR DEPTH OF SEWER HUB AND SPIGOT CAST IRON PiPE BELOW FLOOR SANITARY OR STORM SEWER LINE LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. PROVIDE BACKFILL. PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS I8" CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. ROOF • • • COMBINATION TEMPERATURE 4 PRESSURE RELIEF VALVE (I50 PSI) 3/4" COPPER DRAIN TO TERMINATED TO THE EXTERIOR OF BUILDINS i +.•••• ID I * I - I • FLOOR CLEANOUT / / HOT WATER (-AMER ICE IN 3/4" • NOT TO SCALE SAME SIZE AS SEWER UP TO 4" MAXIMUM. LONG SWEEP ELBOW AT END OR TURN OF RUN. COMBINATION WYE AND EIGHTH BEND IN RUN. ENTER TOP OF PIPE. DIRECTION OF FLOW TWO -WAY GLEANOUT FOR LOCATION, SEE DWG P -I.O NOT TO SCALE VENT CAP / WE / THER ELD / 36" /' FLASHING I " CLEARANCE BETWEEN 'FVE AND COMBUSTIBLE \ MA I tKlAL NOTE: WATER HEATER PUJE SHALL TERMINATE I ABOVE OR S' AWAY FROM PARAPET WALL FLUE VENT DETAIL " VACUUM RELIEF VALVE: "WATTS" OR EQUAL --( COLD WATER UNI ON- TYP. ELEC. WATER HEATER 1/2" GOLD WATER SUPPLY DOWN IN PARTITION WHERE SHOWN ON PLAN. ADAPTER AND SIX FOOT LONG 3/8" REINFORCED FOOD GRADE PLASTIC TUBING TO CUBER WATER INLET. USE HOSE CLAMPS AS REQUIRED. CONNECT TO CUBER AND ICE BIN DRAIN OUTLETS AS REQ'D. REFER TO "INDIRECT DRAIN° DETAIL FOR MORE INFORMATION. (9) � 3 /S "4' LONG LAG BOLTS THRU. BLOCKING OR STUDS (T(P. 4) SECURE HEATER TO WALL I6GA x 2" STEEL STRAP (TiP. 2) 22GA GALV STEEL PAN ALL WELDED WATER TIGHT CONSTRUCTION PAN SHALL DRAIN TO EXTERIOR OF BUILDING NOTE: DRAIN PAN AND T4P DRAIN SHALL BE INSTALLED INDEPENDENTLY TO THE EXTERIOR OF THE BUILDING. PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT IN PARTITION OR CHASE INHERE SHOWN ON PLAN. HORIZONTAL VENT BELOW FLOOR 15 NOT PERMITTED. IF FLOOR DRAIN/SINK IS MORE THAN 5' ON A 2" WASTE OR 6' ON A 3" WASTE FROM THE PARTITION, PROVIDE A TRAP AND WASTE LINE TWO PIPE SIZES LARGER THAN THE DRAIN /SINK OUTLET, WITH A REDUCER ON THE TRAP INLET, AND VENT WITHIN 15 FEET. OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE. I CONCRETE FLOOR REDUCING 1 1 - i - = - = l; = I ®I = lItm- MEM I,' � � irmr=* -� I 5E S ING COLA ND GLAMP- I 3 � 1wPAG IE :I 711 � 1 1 a l l i I ©MAXIMUM TAILPIECE �, MAXIMUM 15' INHERE I- LENGTH IS 2 FEET. ENLARGED WASl1 I _C- I I _I ®8� + :1 SLOPE WASTE AT LINE IS USED AS A = © %E 1 �T PERCENT. COMBINATION WASTE =J I r " AND VENT SYSTEM. PROVIDE TRAP PRIMER IF RE- QUIRED BY LOCAL AUTHORITIES. / MAXIMUM 5' ON 2" OTHERWISE DEEP -SEAL P -TRAP. WASTE OR 6' ON 3 ". LOCATE FLOOR DRAIN/SINK WHERE SHOWN ON DIMENSIONED ARCHITEC- TURAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR SINK, MOVE SIDEWAYS iF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC. IF SITUATION IS FLOOR SLAB ON GRADE, PROVIDE BACKFILL PER SPECIFICATIONS. IF CONCRETE FLOOR 15 NOT EXISTING, SET DRAIN IN PLACE AND POUR AROUND 1T. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL IT. SET DRAIN BODY IN PLACE AND POUR AROUND IT. RECESS TOP OF FLOOR SINKS 1/2" BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT. DO NOT RECESS TOP OF FLOOR DRAINS. IF SITUATION 15 FLOOR NOT ON GRADE, REFER TO "FLOOR PENETRATION" DETAIL FOR VENTS. -3li 2" VENT IN WALL TWO OR THREE COMPARTMENT SINK AIR INTAKE GLEANOUTS IN ENDS OF PIPE. FLOOR 2" COPPER PI PROVIDE LEAD OR COPPER FLASHING OR SPUN ALUMINUM BASE IN BED OF MASTIC. COORDINATE WITH ROOFER. ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. COPPER PIPE, FITINGS AND CONNECTORS ALL AROUND SINK AND TRAP. CONNECT TRAP FROM CENTER COMPARTMENT. PROVIDE CLEANOUT TEE I WITH SCREWED COUNTER- SUNK ABS PLASTIC PLUG: I TAPERED - THREAD WITH TFE JOINT COMPOUND. WHERE CLEANOUT TEE iS CONCEALED IN A CHASE OR PARTITION, PROVIDE A ROUND 18 GAUGE STAINLESS STEEL COVER WITH BEVELED EDGES AND FLATHEAD MACHINE SCREW. I II FLOOR DRAIN /SINK NOT TO SCALE x FS. CONCRETE E R R TO PLUMBING FLOOR � I IXIURE SCHEDULE SLAB. -� I ®I IFOR FURTHER = I I EINFORMATION. PROVIDE CO W AT BASE OF ALL RAIN - LEADER DOWNSPOUTS. ���� 4� PROVIDE NCO WHERE SHOWN ON PLAN, AND ON SANITA}�af' ®D CC IMP BRANCHES NOT SERVED WITH A FLOOR GL-EANLAJ I : , 3 FD LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR. `fi CONSULT LOCAL CODES FOR OTHER INGO REQUIREMENTS. i. STEPPED FLEXIBLE PVC OR NEOPRENE COUPLING CLAMPED TO FLASHING AND PIPE WITH STAINLESS STEEL SCREW CLAMPS. RIGHT AND LEFT NIPPLE $ COOPI NGS Igge CPC SEE #1211.10 ROOFING OVER METAL FLASHING BY ROOFING CONTRACTOR. L ROOF INSULATION 1 II ROOF DECK CLEANOUT -,, 0 3" WASTE �� • O TERGE TTOR UTILITY SINK NTS COLUMN OR PARTIT1ON AS SHOWN ON FLOOR PLAN. GLEANOUT FACE SHALL BE WITHIN 4" OF WALL SURFACE. PROVIDE PIPE EXTEN- SION IF REQUIRED. NOT TO SCALE ELBOWS TO COMPENSATE FOR PIPE EXPANSION. ROOF SUPPORT. REFER TO DETAIL. SLEEVE ROOF' IF REQUIRED. ANCHOR PIPE TO ROOF DECK OR JOISTS. REFER TO PLANS FOR PIPE SIZE(S) AND LOCATION(S).USE WELDED OR SCREWED FITTINGS AS SPECIFIED FOR PIPE SIZE. LOCATE PENETRATION MINIMUM IS" FROM ADJACENT WALLS GAS PIPE ROOF PENETRATION 8 NOT TO SCALE ROOFING DIRECTION OF GRAIN. STUB ELBOWS ABOVE FLOOR AT LOCATIONS SHOWN ON PLAN, 4" ON GARBONATOR END, 4" ON DISPENSER END. SEAL TO CABINET WITH SILICONE. I IMI ®1 ©1= = • k lk loll 11E11 I E1=1. If -�k�I • 4 LENGTH AS REQUIRED USE FOUR INCH P.Y.G. FITTINGS AND COUPLINGS. USE MINIMUM QUANTITY OF COUP- LINGS REQUIRED, SEALED INATER-- TIGHT. USE LONG SWEEP EL35O1.15 AT BOTH ENDS, MINIMUM TWENTY FOUR INCH RADIUS. AVOID ELBOWS IN HORIZONTAL RUN IF AT ALL POSSIBLE. BELOW - GROUND SODA CONDUIT BY G,SS COMPANY (VERIFY) F PRESSUkE COCK GAS METER RF CFH CAPACITY SHOT ON PLANS STRAINER (OPTIONAL) SHUT FF VALVE \ VERIFY REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY. INSTALL OTHERATILITIES MINIMUM TEN FEET FROM 6.AS LINE. PLUMBING CONTRACTO 'SHALL PAY ALL GAS COMPANY FEES FQR INSTALLATION. USE WELDS OR SCREWED PIPE AND FITTINGS PER PLUMING SPECS. GAS GO ANY SHALL EXCAVATE, BACKFILL, AND REPAIiR..,ANNY PAVING OR SO FOR GAS SERVICE LINE INSTALLATION FROM MAIN` BUILDING. PAS EXPOSED METAL GAS PIPE, FITTINGS AND ITEMS LIGHTN. DRILL HOLE IN SIDE OF BOX AND PROVIDE SILICONE SEAL AROUND PIPE PENETRATION. PRESSURF/REGULATOR TLR REDUCE PRESSURE TO 7" G. PROVIDE TRAP rr, AT BOTTOM OF RISER AND DIS- CHARGE INTO FLOOR DRAIN OR FLOOR SINK WITH AIR GAP OF TWICE PIPE DIAMETER. FLOOR 1/4" x 1 -1/2" CADMIUM - PLATED LAG SCREWS I8 "x18 "xI /2" THICK ROO F WALKWAY MATERIAL FOR BASE SHEET. ( "CAREY -TRED" OR PER ARCHITECTURAL SPECIFICATIONS.) BY PLUMBING CONTRACTOIFc / EXTERIOR BUZDING WALL. GAS PIPE UP ONTO ROOF. SIZE AS 4IOINN ON PLAN. USE BL�AGK STEEL PIPE. P INCREASER. FLOOR GAS SERVICE 3/4 "3/4"-\\ NOT TO SCALE NOT TO SCALE / DIRT LEG AT BOTTOM OF RISER. ANCHOR RISER TO WALL. DX COIL COORDINATE ROUTING OF DRAIN WITH SHELVING IN WALK -1N BOX. CO PROVIDE CLEANOUT IN TURNS AND ENDS OF PIPE. MAKE CONNECTION TO COIL AS REQUIRED. NO INSULATION ON PIPE RISER. WALK -IN COOLER OR FREEZER BOx. WALL CLEAN O U "4 � ` � 4 7 " WALK - IN BOX CONDENSATE DRAIN PRIMER COAT AND PAINT EXTERIOR SAS PIPE LIGHT GREEN COLOR. ROOF PIPE SUPPORT NOT TO SCALE / PROVIDE I" ELASTOMERIC INSULATION OVER HEAT TRACING ON CONDENSATE W LINE (FOR FREEZER BOX ONLY) BY ALK IN BOX INSTALLER, (Pi FGTRIG HEATING CABLE 15 BY CONTRACTOR). SEE FLOOR PLAN FOR RECEPTACLE LOCATION. INSTALL PIPE HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE TYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD -FREE SOWER JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREfri elVED CITY 1K1AntA Nov 28 2007 GALVANIZED STEEL CLAMP. DO NOT CLAMP PIPE TIGHT. 4" " 6" x 12" REDWOOD V SUPPORT BLOCK OR GGA ROT -PROOF TREATED TIMBER. V -NOTCH TIMBER PROVIDE MULTIPLE BASE SHEETS OR TRIM THE TIMBER AS REQUIRED TO ACCOMODATE VARIATIONS IN ROOF ELEVATION. LOCATE AT TURNS OF PIPE, AT 4' SPACING FOR PLASTIC PIPE, AND AT THIS SPACING FOR METAL PIPE: 5 " =I6' 4 " =14' 3 " =12' 2- I /2 " =II' 2 " =I0' I- I/2 " =g' 1- 1/4 " =8' 1 " = 3/4 " =6'. PLAGE BASE SIILETS ON ROOFING BEFORE GRAVE- IF ANY. SET BLOCKS FREE ON BASE SHEETS. STACK BLOCKS AND NAIL THEM TOGETHER WHERE REQUIRED TO ELEVATE PIPING. HYG GONSULTI NCB ENGINEERS, Inc. 556 N. Diamond Bar Blvd., #304 Diamond Bar, California g1165 Tel :(gOq)3g6 -8168• Fax: (gOq)3g6.8I6q• E - mati:HYG ©HYGENGINEEER.GOM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.7ciGI.gfYIS Facsimile: 626.312152S5 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person. firm, or corporation without the written permission of Panda Express Inc. ISSUE DATE: DRAWN BY: S.G. PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE, SUITE #301 ROSEMEAD, CA 91770 TEL: 626.280.9188 FAX: 626280.9189 E -MAIL INFO @CALARC.NET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC-10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 P -4.0 PLUMBING DETAILS Z:1Cal Arc ProJect107 Prof ect -CAL Arc107 -1 PX concstructlon dacument1170705 PX @ South Center Mall, Tukwila, WA M1 -08•x1189 MEP ardyfOIs5I11707U5RflnYCiCPC0719 PLUM.dwg,11/137007 8:50:08 PM, am TDS4001xpc3