Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG07-322 - WESTFIELD SOUTHCENTER MALL - JOURNEYS
JOURNEYS 2477 SOUTHCENTER MALL PGO7-322 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 24U SOUTHCENTER MALL TUKW JOURNEYS 2477 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: THOM TOBEN Address: 8010 STATE LINE RD STE 180 , LEAWOOD KS Contractor: Name: ELDER JONES INC Address: 1120 E 80TH ST , BLOOMINGTON, MN Contractor License No: ELDERJI1590Q DESCRIPTION OF WORK: PLUMBING SYSTEMS FOR TENANT IMPROVEMENT FOR NEW MALL SPACE INCLUDING INSTALLATION OF 0.75" RPPA. Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 $7,200.00 $157.50 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or mater cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet FIXTURE TYPE AND OUANTITY * *continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 913 - 649 -6037 Phone: 612 -854 -2854 Expiration Date: 01/11/2009 PG07 -322 05/15/2008 11/11/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) O Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type O grease interceptors 0 0 Repair or alteration of water piping and/or water 1 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 1 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 O Medical gas piping (6 +) inlets /outlets 0 1 Gas Piping 0 Gas piping outlets (0 -5) 0 1 Gas piping outlets (6 +) 0 PG07 -322 Printed: 05-15 -2008 Print Name: doc: UPC -10/06 Permit Center Authorized Signature: I hereby certify that 1 have read and d governing this work will be complied City o 'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us a it Permit Number: PGO7 -322 Issue Date: 05/15/2008 Permit Expires On: 11/11/2008 APO? 0l Date: t(isPP ned this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the per orma a of work. I authorized to sign and obtain this plumbing /gas piping permit. Signature: � Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -322 Printed: 05-15 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: JOURNEYS doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2477 SOUTHCENTER MALL TUKW 1: ** *PLUMBING AND GAS PIPING * ** 13: ** *PUBLIC WORKS DEPARTMENT CONDPPIONS * ** 15: Proposed RPPA shall be installed according to manufacturer specs. PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG07 -322 ISSUED 11/30/2007 05/15/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 1 I: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 14: The applicant must notify the City Utility Inspector at (206)433 -0179 upon commencement and completion of REDUCED PRESSURE PRINCIPLE ASSEMBLY (RPPA) installation work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. PG07 -322 Printed: 05-15 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: PG07 -322 Printed: 05-15 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hitp://www.atukwila.wa.us / c�M `' 7 7 King Co Assessor's Tax No.: l� � OM U Site Address: /a .Sat ce-krz - goarL/e , Suite Number: j3 or Floor: ii 1447 Tenant Name: 4z►a f-44E /S New Tenant: Mr Yes El -.No Property Owners Name: (7g/4440 G" (v — //give/ jole6a,g(7 / Mailing Address: /f/ /1' Aidiien f##e, 4 2 7 0V Ali&1. /1 i 372/7 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name° fl fr1 e-r Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Mailing Address: / i 6 S Pfi !, god r7 /' E -Mail Address: ! ,7oA i e % 2V. ce04 GENERAL CONTRACTOR INFORMATION (Contractor Information #oc Mechanical °(pg 4) for Plumbing a nd Gas Piping (pg 5)) Company Name: C /-1 VIC7 Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OFRECORD All plans must be wet stamped by Architect of Recor Company Name: 57W12, 6 - Mailing Address: gd / .5 1/ Z6z2 57A - Contact Contact Person: —1 /h$r1 "7d�3j E -Mail Address: L STZ r7 . Co4'I ENGINEER OF RECORD All plans must be wet stamped by Engineer Company Name: 9 Vii✓ %'� � -�f /' /41irlts c Mailing Address: 5 --) Contact Person: . gtc# E -Mail Address: Re <<-Mel 3 C Ceti► Q: Applications\Fc,ms- Applications On line\3 -2006 - Permit Application.doc Revised: 9 -2006 bb Building Permit No. 1 — Mechanical Permit No: rta - 7- Plumbing/Gas Permit No O I Public Works Permit No. Project No. poi (For office use only) Day Telephone: 7/7- (7 P 66 37 4 4cer /cf. 6 e p City State Zip Fax Number: 7/ 3 • 6 SSA -7 /// City Day Telephone: Fax Number: Expiration Date: State Zip .t dewcc>o' e6 Zot City State Zip Day Telephone: 9/3. 4 Y 644 7 7 Fax Number: 7/ 3. 6// '7/// City State Zip Day Telephone: 9/4 . 26 z - / 7 7 Z Fax Number: 9/3 . 26 z- /77 3 Page 1 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty ; Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain I Sinks / Dental unit, cuspidor Shower, single head trap ll; Urinals Dishwasher, domestic, with independent drain Lavatory / Water Closet / Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent I Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Company Name: Mailing Address: PLUMBING AND GAS PIPING CONTRACTOR INFORMATION d Building Use (per Int'l Building Code): /1 Occupancy (per Int'l Building Code): /4 Utility Purveyor: Water: " " r d , ii— 4 Q: 1Applications\Fonns- Applications On Line13 -2006 - Permit Application.doc Revised: 9 bh Oro PLUMBING AND GAS PIPING PERMIT INFORMATION - 206-431-3670 City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 2 ' j . 7./e r y Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): ivl d / a Or N ✓ Rb 6/4 - Sewer: %Jx Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING .OWIVEIOR AUTNOWED A Si re: Print Name. 7 Mailing Address: /O 5747X e4sei R 1,9 Date Application Accepted: QApplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bit Day Telephone: ,C /4cd o City Date: /0G /1 y13, DVS 4. /Cf. 6,614P State Zip Date Application Expires: S -30- o 8 Staff Initials: Page 6 of 6 Doc! RECSETS -OR RECEIPT NO: R08 -01658 Initials: WER User ID: 1655 Payee: ELDER -JONES SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http.• //www. ci. tukwila. wa. us D07 -440 1,999.88 D08 -004 223.74 M07 -259 295.42 PG07 -322 128.00 TOTAL: 2,647.04 BUILDING - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE SET RECEIPT SET ID: 0515A SET NAME: JOURNEYS Payment Date: 05/15/2008 Total Payment: 2,647.04 TRANSACTION LIST: Type Method Description Amount Payment Check 133793 2,647.04 TOTAL: 2,647.04 Account Code Current Pmts 000/322.100 2,209.88 000/322.100 295.42 000/345.830 4.74 000/322.100 128.00 000/386.904 9.00 TOTAL: 2,647.04 2494 05/16 9710 TOTAL 2647.04 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PGO7 -322 Address: 2477 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/30/2007 Applicant: JOURNEYS Issue Date: Receipt No.: R07 -02627 Initials: WER Payment Date: 11/30/2007 10:43 AM User ID: 1655 Balance: $128.00 Payee: STUDIO T2 DESIGN TRANSACTION LIST: Type Method Description Amount Payment Check 5710 29.50 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 29.50 Total: $29.50 Payment Amount: $29.50 doc: Receiot -06 Printed: 11 -30 -2007 Project:-.7 0 2/Q Type of Inspection: F //tip/ — /)lItin A esg:,7 7 /77/9 // Date Called: Special Instructions: Date Wanted: / -7 -- /tom - Oe (ate p.m. Requester: Pho a No: g� 3 —,z'a 6/ INS ECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ; d /c. 7.7rieltell Inspector: 2 / ( �� J $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Date: 7 y Projects.-- - Jou. n I° /S Type of Inspection: �iracx. (Joel Ad�r Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: : 5 -ica i CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Inspector: EJ $60.00 paid a INSPECTION NO. INSPECTION RECORD Retain a copy with permit Approved per applicable codes. El Corrections required prior to approval. ( V NSPECTION FEE REQUIRED. Prior to inspection, fee must be 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: (Date: 04 -04 -2008 THOM TOBEN 8010 STATE LINE RD STE 180 LEAWOOD KS 66208 RE: Permit Application No. PG07 -322 2477 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 11/30/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 05/28/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 05/28/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, ifiiii„ xc: fer Marshall 't Technician Permit File No. PG07 -322 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 December 4, 2007 Thom Toben 8010 State Line Rd Ste 180 Leawood KS 66208 RE: Letter of Incomplete Application # 1 Plumbing/Gas Piping Permit Application PG07 -322 Journeys — 2477 Southcenter Mall Dear Mr. Toben, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on November 30, 2007 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department needs to be addressed: Public Works Department: Joanna Spencer at 206 431 -2440 if you have any questions concerning the following comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made In person and will not be accepted throuih the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician Enclosures File: PG07 -322 City of Tukwila Department of Community Development Steve Lancaster, Director 1. Please provide additional information per attached mark-up. *0;1Q P:\Permit Center\lncomplete Letters\2007\PG07 -322 Incomplete Ltr #1.DOC wer Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PLAN REVIEMOUTING SLIP ACTIVITY NUMBER: PG07 -322 DATE: 01 -04 -08 PROJECT NAME: JOURNEYS SITE ADDRESS: 2477 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS• . ing Division 1 ir il- Pu _ic orks on 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Fire Prevention Structural ❑ Permit Coordinator IC Incomplete Structural Review Required Planning Division DUE DATE: 01 -08 -08 El Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 02-05-08 Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 C ACTIVITY NUMBER: PG07 -322 DATE: 11 -30 -07 PROJECT NAME: JOURNEYS SITE ADDRESS: 2477 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division X Fire Prevention El Planning Division E Public WQr�ks Structural Ell Permit Coordinator X CIIS ILPM, a (i -c -o1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -04 -07 Complete ❑ Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 9=4 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW V Initials: V" TUES/THURS ROUTING: Please Route `PERMIT COORD COPY ` PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Documents/routing stip.doc 2-28-02 Structural Review Required Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 01 -01 -08 n Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: / �� S/07 Plan Check/Permit Number: PGO7 -322 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Journeys Project Address: 2477 Southcenter Mall Contact Person: Thom Toben Phone Number: ��3• '" 6,0 37 Summary of Revision: dam' 1 3t V ? SiteeftT P. / f Z A 3 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision tl Received at the City of Tukwila Permit Center by: Entered in Permits Plus on i"( — 0 g \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director rtECEIVLU crrl OF TUKWIIA i IAN -.4 2QO License Information License ELDERJI159OQ Licensee Name ELDER JONES INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600592836 Ind. Ins. Account Id #8 Business Type CORPORATION Address 1 1120 E 80TH ST Address 2 City BLOOMINGTON County OUT OF STATE State MN Zip 55420 Phone 8003286907 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/18/1985 Expiration Date 1/11/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ELDER, JOHN S Cancel Date 01/01/1980 Bond Amount GOODERMONT, DAVID #8 01/01/1980 69564459 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #8 WESTERN SURETY CO 69564459 07/31/2003 Until Cancelled $12,000.00 08/18/2003 VIGILANT Until Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ELDERJI1590Q 05/15/2008 MECHANICAL SPECIFICATIONS I. GENERAL PROVISIONS: A. PROVIDE ALL LABOR MATERIALS, EQUIPMENT, NECESSARY FOR THE COMPLETE INSTALLATION OF THE PLUMBING AND MECHANICAL SYSTEMS OUTLINED. B. OBTAIN ALL PERMITS, FEES, LICENSES, INSPECTIONS, AND CERTIFICATES OF COMPLIANCE OR APPROVAL AS REQUIRED BY THE AUTHORITIES. G. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND REGULATIONS OF THE GOVERNMENTAL BODIES HAVING JURISDICTION OVER THE SITE. D. ALL TESTING REQUIRED BY AUTHORITIES SHALL BE CONSIDERED PART OF THIS WORK. E. DURING CONSTRUCTION, ALL FIXTURES, EQUIPMENT, PIPE, DUCT, ETC. SHALL BE COVERED, PLUGGED, OR GAPPED AS REQUIRED TO KEEP CLEAN AND UNDAMAGED. ALL DAMAGED ITEMS SHALL BE RESTORED TO ORIGINAL CONDITION OR REPLACED. ALL PROTECTIVE COVERING SHALL BE REMOVED BEFORE FINAL ACCEPTANCE. F. PROVIDE ALL NECESSARY CUTTING AND PATCHING OF WALLS, FLOORS, CEILINGS, AND ROOFS AS NECESSARY. PATCH AROUND ALL OPENINGS SHALL MATCH ADJACENT AREA. COORDINATE ALL ROOFING WORK WITH OWNER OR IR PONSIBLE PARTY, SO THAT THE EXISTING ROOFING WARRANTY WILL BE MAINTAINED. G. CONTRACTOR SHALL GUARANTEE ALL. WORK AND MATERIALS AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE. 2. OPERATION AND MAINTENANCE MANUALS: A. DURING THE COURSE OF CONSTRUCTION, COLLECT AND COMPILE OPERATING INSTRUCTIONS, WIRING DIAGRAMS, CATALOG CUTS, LUBRICATION AND PREVENTIVE MAINTENANCE INSTRUCTIONS, PARTS LISTS, ETC. FOR ALL EQUIPMENT FURNISHED UNDER THIS CONTRACT. B. ALL LITERATURE AND INSTRUCTIONS SHIPPED WITH THE EQUIPMENT SHALL BE SAVED FOR INCLUSION IN THE OPERATION AND MAINTENANCE MANUALS. G. ALL LITERATURE LISTED ABOVE AND ALL PAPERS LISTING. WARRANTiES, ETC SHALL-. BE BOUND IN A 3 -RIN6 BINDER AND LABELED WITH THE PROJECT NAME, ADDRESS, ARCHITECT, ENGINEER, CONTRACTORS, ETC. 3. MANUFACTURERS: A. MANUFACTURERS, MODEL NUMBERS, ETC. INDICATED OR SCHEDULED ON THE DRAWINGS SHALL BE INTERPRETED AS HAVING ESTABLISHED A STANDARD OF QUALITY AND SHALL NOT BE CONSTRUED AS LIMITING COMPETITION. ARTICLES, FIXTURES, ETC. OF EQUAL QUALITY BY MANUFACTURERS SHALL BE ACCEPTABLE, Shy E T TO STRUCTURAL AND FI FGTRIGAL CONSTRAINTS OF THE PROJECT DESIGN, UNLESS NOTED OT EF NISE. 4. MOTORS: A. PROVIDE THERMAL OVERLOAD PROTECTION FOR EACH MOTOR PROVIDED BY THIS WORK 5. TESTING, BALANCING, AND GLEANING: A. ALL PIPING SHALL BE TESTED FOR LEAKS BEFORE BEING CONCEALED IN WALL_ CONSTRUCTION OR COVERED WITH INSULATION. B. FIRE PROTECTION PIPING SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA. G. DUCTWORK AND PIPING SHALL BE BALANCED BY QUALIFIED BALANCING PERSONNEL WHO HAVE PREVIOUS EXPERIENCE WITH BALANCING PROCE DUIRES. 6. PIPING: A. CONDENSATE DRAINS B INDIRECT WASTE (ABOVEGROUND). I) PWV, WROUGHT COPPER, ANSI B -I62Q ( INSIDE BUILDING). B. ALL PIPE HANGERS AND SUPPORTS SHALL BE STANDARD PRODUCTS OF GRINNELL, FEE AND MASON, OR ELLEN. HANGER SPACING SHALL BE IN ACCORDANCE WITH 1.455- 5P-64. G. SLEEVES I) PROVIDE, SET, AND PROPERLY LOCATE PIPE SLEEVES AS REQUIRED FOR THIS WORK. ALL SLEEVES SHALL BE OF SUFFICIENT SIZE TO PERMIT PIPE MOVEMENT DUE TO EXPANSION AND CONTRACTION AND TO ACCOMMODATE PIPE INSULATION. 2) INTERIOR PARTITIONS: 16 GAGE GALVANIZED STEM , PACK BETWEEN PIPE AND SLEEVE WITH FIRE SAFING AND CAULK AT EACH END WITH FIRE RESISTANT SEALANT. 3) ROOF: PROSET OR EQUAL, MANUFACTURED PVC SCHEDULE 40 PIPE SLEEVE WITH WATERPROOF SEAL. COORDINATE WITH ROOFING CONTRACTOR AND FLASH AS REQUIRED TO MAINTAIN ROOF WARRANTY. 4) PLUMING VENTS: FLASH ROOF VENT INTO ROOFING SYSTEM AS REQUIRED BY THE ROOFING. CONTRACTOR TO MAINTAIN EXISTING ROOF WARRANTY. •v■ E. DOMESTIC COW AND HOT WATER (ABOVEGROUND). I) TYPE L HARD DRAWN COPPER TUBING, ASTM B 2) WROUGHT BRONZE SOLD EP FITTINGS. 3) GATE VALVE: CRANE # 42S OR EQUAL. 4) GLOBE VALVE: CRANE #T OR EQUAL. 5) BALL VALVE: CRANE #432 OR EQUAL. F. DOMESTIC GOLD, AND HOT WATER (IUiNDERGPOUND). I) TYPE K HARD OR SOFT DRAWN COPPER TUBING, ASTM B-SS. 2) Y1GHT BRONZE SOLDERED FITTINCr. 6. SANITARY SEATER, AND VENTS ). I) SERVICE; WEIGHT, BELL- AND - SPIGOT, COATED GAST IRON, ASTM A-14. 2) DWV, WROUGHT COPPER, ANSI B - 16.2G. • "NO --RUB" GAST IRON, NEOPRENE GASKETS, STAINLESS STEEL CLAMPS. H. SANITARY SEWER, AND VENTS (ABOVEGROUND). I) SERVICE WEIGHT, BELL- AND-5PIGOT, COATED CAST IRON, ASTM A-14. 2) DWV WROUGHT COPPER, ANSI 13-16.2cf. 3) GALVANIZED STEEL PIPE, WITH MALLEABLE IRON, THREADED FITTINGS, DRAINAGE PATTERN FOR SEI ERS, 4) NO-HUB" CAST IRON, NEOPRENE GASKETS, STAINLESS STEEL CLAMPS. ■ 7. INSULA A. B. S. PLUMBING: A PIPE INSULATION: P a) DUCT COVERING SCHEDULE: (I) ROUND SUPPLY DUCT 2' (2) OUTDOOR AIR DUCT 2° I) VINYL TILE FLOOR: JR SMITH #4140, OR EQUAL.. 2) QUARRY TILE FLOOR: JR SMITH #4200, OR EQUAL. 3) CARPETED FLOOR: JR SMITH #4020 -Y, OR EQUAL. 4) UNFINISHED FLOOR: JR SMITH #4020, OR EQUAL. 5) WALL: JR SMITH #4472, OR EQUAL, 24 ABOVE THE FLOOR. NG FINISHED AREAS. ALL INSULATIONS AND ACCESSORIES SHALL HAVE A FIRE HAZARD CLASSIFICATION WITH A FLAME SPREAD RATING OF NOT OVER 25, A FUEL CONTRIBUTION RATING OF NOT OVER 50, AND A SMOKE DEVELOPED RATINS OF NOT OVER 50, IN ACCORDANCE WITH NFPA. I) FIBERGLASS INSULATION WITH FACTORY APPLIED VAPOR BARRIER, AS-1 JACKET, FACTORY APPLIED PRESSURE SEALING LONSITUDAL LAP JOINT, NO STAPLES, ZESTON PREMOLDED PVC FITTING COVERS. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2) FLEXIBLE CLOSED CELL ELASTOMERIC THERMAL INSULATION, UNSLIT OR PRESLIT WITH PRESSURE SENSITIVE ADHESIVE SYSTEM FOR CLOSURE AND VAPOR SEALING, EQUAL TO ARMSTRONG AP ARMAFLEX OR ARMAFLEX 2000. 3) INSULATION SCHEDULE: a) CONDENSATE DRAINS INSIDE BUILDING. 1/2 C. DUCTWORK I) DUCT LINING: 2 LB/GE, THICKNESS AS SCHEDULED, AIR STREAM SIDE COATED, INSTALL PER SMAGNA STANDARDS. a) DUCT LINING SCHEDULE: (I) RECTANGULAR SUPPLY DUCT 1/2" (2) RETURN AIR DUCT 1/2" 2) DUCT COVERING: 3/4 LB /CF, FIBERGLASS BLANKET WITH FACTORY APPLIED VAPOR BARRIER AND FACING, THICKNESS AS SCHEDULED, INSTALLATION IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. A. PROVIDE AN AIR CHAMBER NOT LESS THAN 24' LONG AND ONE PIPE SIZE LARGER THAN THE PIPE SIZE CONNECTED TO THE FIXTURE, BUT NOT LESS THAN 3/4 ", FOR EACH FLUMING FIMURE SUPPLY_ B. ALL EXPOSED PIPE SHALL BE CHROME PLATED BRA55 PIPE, NO FERROUS PIPE. G. PROVIDE CLEANOUTS AT EACH CHANGE OF DIRECTION AND AT 100 FOOT INTERVALS IN STRAIGHT RUNS. D. PROVIDE ACCESS PANELS FOR ALL CONGEALED VALVES AND TRAPS. E. CLEANOUTS: F. PROVIDE DIM FOTIRIC UNIONS WITH APPROPRIATE END CONNECTIONS TO MATCH THE PIPE SYSTEM IN WHICH INSTALLED (SCREWED, SOLDERED, OR FLANGED). PROVIDE DIELECTRIC UNIONS ON ALL PIPING CONNECTIONS TO HOT WATER HEATERS AND EXPANSION TANKS. 4. DUCTWORK: A. ALL. DUCTWORK, UNLESS OTHERWISE INDICATED, SHALL BE FABRICATED FROM GALVANIZED SHEET STEL. COMPLYING WITH ASTM A 521, LOCK-FORMING QUALITY, WITH G 60 ZINC COATING IN ACCORDANCE WITH ASTM A 525; AND MILL. PHOSPHATiZED FOR EXPOSED LOCATIONS. B. DUCTWORK, METAL GAUISF , REINFORCING, ETC. SHALL SE CONSTRUCTED IN ACCORDANCE WITH SMACNA "HVAG DUCT CONSTRUCTION STANDARDS," LATEST EDITION FOR A 2 INCH WATER GAUGE STATIC PRESSURE. G. ALL FITTINGS SHALL BE CONS IN ACCORDANCE WITH SMACNA "WAG DUCT CONSTRUCTION STANDARDS; LATEST EDITION. D. SEAL ALL DUCTWORK JOINTS WITH NON - HARDENING', NON - MIGRATING MASTIC SEALANT, AS RECOMMENDED FOR SEALING SEAMS AND JOINTS IN DUCTWORK OIL BASE CAULKING AND GLAZING COMPOUNDS SHALL NOT BE ACCEPTABLE. E. DUCT SIZES SHOWN ON THE DRAWINGS ARE SHEE METAL SIZES, ALLOWANCE FOR DUCT LINER HAS BEEN MADE WHERE APPLICABLE. 10. FLEXIBLE DUCT: A. TECHNAFLEX SERI FS WK, OR EQUAL. B. FACTORY APPLIED INSULATION AND VAPOR BARRIER, 1 - 1/2° THICK_ C. MAXIMUM LENGTH II. CONTROL WIRING: A. FI F ,TRIGAL WIRING AND WIRING CONNECTIONS REQUIRED FOR THE INSTALLATION OF THE TEMPERATURE CONTROL SYSTEM, SHALL BE PROVIDED 13Y THIS CONTRACTOR, UNLESS SPECIFICALLY SHOWN ON THE FI ErTRIGAL DRAWINGS OR SPECIFICATIONS. B. INSTALL CONTROL WIRING, WITHOUT SPLICES BETWEEN TERMINAL POINTS, COLOR CORED. INSTALL IN NEAT WORKMANLIKE MANNER, SECURELY FASTENED. INSTALL IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND THE ELECTRICAL SPECIFICATIONS. I) INSTALL CIRCUITS OVER 25 VOLT WITH COLOR CODED NUMBER 12 WIRE. 2) INSTALL CIRCUITS UNDER 25 VOLT WITH COLOR CODED NUMBER IS WIRE WITH 0.031 INCH HIGH TEMPERATURE 105 DEGREES F PLASTIC INSULATION ON EACH CONDUCTOR AND PLASTIC SHEATH OVER ALL. 3) INSTALL ELECTRONIC CIRCUITS WITH COLOR CODED NUMBER 22 WIRE WITH 0.023 INCH POLYETHYLENE INSULATION ON EACH CONDUCTOR WITH PLASTIC JACKETED COPPER SHIELD OVER ALL. 4) INSTALL LOW VOLTAGE CIRCUITS, LOCATED IN CONCRETE SLABS AND MASONRY WALLS, OR EXPOSED IN OCCUPIED AREAS, IN ELECTRIC CONDUIT. 5) ALL WIRING IN AREAS USED AS AIR PLENUMS SHALL BE IN ELECTRIC CONDUIT EXCEPT THAT LOW VOLTAGE WIRING MAY BE TEFLON COATED, ALUMINUM SFEATHED GABLE OR OTHER. HIRE SPECIFICALLY APPROVED FOR INSTALLATION IN AIR PLENUMS, WHERE ACCEPTABLE BY LOCAL CODES. 6) ALL WIRING IN AREAS NOT USED FOR AIR MOVEMENT SHALL BE IN ELECTRIC METALLIC TUBING EXCEPT LOW VOLTAGE WIRING MAY BE IN APPROVED SIGNAL CABLE WHERE ACCEPTED BY LOCAL CODES. 12. REMODELING WORK: A. DEMOLITION: DISCONNECT, DEMOLISH, AND REMOVE ABANDONED MECHANICAL MATERIALS AND EQUIPMENT INDICATED TO BE REMOVED AND NOT INDICATED TO BE SALVAGED OR REMAIN. B. EQUIPMENT TO BE SALVAGED: I) DISCONNECT AND REMOVE, EXISTING MECHANICAL EQUIPMENT INDICATED TO BE REMOVED AND SALVAGED. DELIVER EQUIPMENT TO THE LOCATION DESIGNATED BY THE OWNER FOR STORAGE. 2) ALL MATERIALS AND EQUIPMENT DESIGNATED TO BE REUSED OR RELOCATED SHALL BE CAREFULLY REMOVED, AND STORED UNTIL NEEDED FOR REMODELING WORK ALL ITEMS SHALL BE RESTORED TO "LIKE NEW" CONDITION WITH RUST OR CORROSION REMOVED, SURFACE PAINT TOUCHED UP OR REPAINTED AS REQUIRED TO MATCH NEON CONSTRUCTION, AND THOROUGHLY CLEANED AND INSPECTED. ANY ITEMS WHICH BECOME DAMAGED BEYOND REPAIR AS A RESULT OF CONSTRUCTION OR DEMOLITION ACTIVITY SHALL BE REPLACED WITH NEN MATERIAL EQUIVALENT IN EVERY RESPECT. G. DISPOSAL AND CLEANUP: REMOVE FROM THE SITE AND LEGALLY DISPOSE OF DEMOLISHED MATERIALS AND EQUIPMENT NOT INDICATED TO BE SALVAGED. D. PROTECT ADJACENT MATERIALS INDICATED TO REMAIN. INSTALL AND MAINTAIN DUST AND NOISE BARRIERS TO KEEP DIRT, DUST, AND NOISE FROM BEING) TRANSMITTED TO ADJACENT AREAS. REMOVE 1 Rf-,OTECTiON AND BARRIERS AFTER REMODELING OPERATiONS ARE COMPLETE. E. LOCATE, IDENTIFY, AND PROTECT MECHANICAL SERVICES PASSING THROUGH REMODELING AREA AND SERVING OTHER AREAS OUTSIDE THE REMODELING LIMITS. MAINTAIN SERVICES TO AREAS OUTSIDE REMODELING LIMITS. WIRE MECHANICAL SERVICES ARE LOCATED IN A WALL, ETC. TO BE DEMOLISHED, REROUTE PIPING TO NEW OR EXISTING CONSTRUCTION TO MAINTAIN CONTINUITY OF THE SYSTEM. WHEN SERVICES MUST BE INTI RRI)PTED, INSTALL TEMPORARY SERVICES FOR AFFECTED AREAS. F. REMOVE ALL PIPING TO BE DEMOLISHED BACK TO PIPE MAIN OR EDGE OF PROJECT AREA, AND CAP PIPE. O. PIPING AND DUCTS EMBEDDED IN FLOORS, WALLS, AND CEILINGS MAY REMAIN IF SUCH MATERIALS DO NOT INTERFERE WITH NEW INSTALLATIONS. PIPING AND DUCTS TO REMAIN SHALL BE APPROVED BY TI ARCHITECT. REMOVE MATERIALS ABOVE ACC SIBL E CEILING. DRAIN AND CAP PIPING AND DUCTS ALLOWED TO REMAIN ABOVE CEILING OR BELOW FLOOR, CONCEALED FROM VIEW, EXCEPT AS OTHERWISE NOTED. PATCH FLOOR TO MATCH EXISTING. H. PIPE AND DUCT SHALL BE CONGEALED WITH NEW OR EXISTING CONSTRUCTION NHVER POSSIBLE, UNLESS INDICATED OTHERWISE. I. GENERAL PROVISIONS: A. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, NECE FOR THE COMPLETE INSTALLATION OF THE ELECTRICAL SYSTEMS OUTLINED. B. C. H FCTRICAL SPECIFICATIONS OBTAIN ALL PERMITS, FEES, LICENSES, INSPECTIONS, AND CERTIFICATES OF COMPLIANCE OR APPROVAL AS REQUIRED BY THE AUTHORITIES. ALL WORK SHALL SE PERFORMED IN ACCORDANCE WITH THE LATEST APPROVED EDITION OF THE NATIONAL ELECTRIC CODE (NEC), AND ALL APPLICABLE LAWS, CODES AND REGULATIONS OP THE GOVLNTAL 6ODIES HAVING JURISDICTION OVER THE SITE. D. ALL TESTING REQUIRED BY AUTHORITIES SHALL BE CONSIDERED PART OF THIS WORK E. DURING CONSTRUCTION, ALL FIXTURES, EQUIPMENT, CONDUIT, ETC. SHALL BE COVERED, PLUGGED, OR CAPPED AS REQUIRED TO KEEL' CLEAN AND UNDAMAGED. ALL DAMAGED ITEMS SHALL BE RESTORED TO ORIGINAL CONDITION OR REPLACED. ALL PROTECTIVE COVERING SHALL BE REMOVED BEFORE FINAL ACCEPTANCE. F. 6. PROVIDE ALL NECESSARY CUTTING AND PATCHING OF WALES, FLOORS, CEILINGS, AND ROOFS AS NECESSARY. PATCH AROUND ALL OPENINGS SHALL MATCH ADJACENT AREA. COORDINATE ALL ROOFING WORK WITH OWNER OR RESPONSIBLE PARTY, 50 THAT THE EXISTING ROOFING WARRANTY WILL BE MAINTAINED. CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE. 2. OPERATION AND MAINTENANCE MANUALS: A DURING THE COURSE OF CONSTRUCTION, COLLECT AND COMPILE OPERATING INSTRUCTIONS, WIRING DIAGRAMS, CATALOG GUTS, LUBRICATION AND PREVENTIVE MAINTENANCE INSTRUCTIONS, PARTS LISTS, ETC. FOR ALL EQUIPMENT FURNISHED UNDER THIS CONTRACT. B. ALL LITERATURE AND INSTRUCTIONS SHIPPED WITH THE EQUIPMENT SHALL BE SAVED FOR INCLUSION IN THE OPERATION AND MAINTENANCE MANUALS. G. ALL LITERATURE LISTED ABOVE AND ALL PAPERS LISTING WARRANTIES, ETC. SHALL BE BOUND IN A 3-RIN6 BINDER AND LABELED WITH THE PROJECT NAME, ADDRESS, ARCHITECT, ENGINEER, CONTRACTORS, ETC. 3. MANUFACTURERS: A. MANUFACTURERSS, MODEL -. NUMBERS, ETC. INDICATED OR SCHEDULED ON THE DRAWINGS SHALL BE INTERPRETED AS HAVING ESTABLISHED A STANDARD OF QUALITY AND SHALL NOT BE CONSTRUED AS LIMITING COMPETITION. ARTICLES, FIXTURES, ETC. OF EQUAL QUALITY BY MANUFACTURERS SHALL BE ACCEPTABLE, SUBJECT TO STRUCTURAL AND ELECTRICAL CONSTRAINTS OF THE PROJECT Dt IGN, UNLESS NOTED OTHERWISE. 4. TESTING, AND BALANCING: A. ALL CIRCUITS SHALL BE T FOR CONTINUITY, SHORTS, AND GROUNDS BEFORE CONNECTING TO THE PROPER PHASE AS DESIGNED TO BALANCE THE LOADING BETWEEN PHASES. B. POWER AND LIGHTING PANELS SHALL BE PROPERLY PHASED TO DISTRIBUTE THE WAD AND SHALL BE CONNECTED AND ADJJSTED TO OPERATE AS SPECIFIED. C. ALL MOTORS AND SIMILAR EQUIPMENT SHALL BE CHECKED FOR PROPER PHASE ROTATION AND OPERATION. 5. RACEWAYS: A_ CONDUIT INSIDE THE BUILDING SHALL BE METALLIC TUBING (EMT), BEARING THE UL LABEL, WITH COMPRESSION TYPE FITTINGS. B. C. P. 6. CONDUCTORS: A. WIRES SHALL BE CONTINUOUS WITHOUT SPLICES OR TAPS IN CONDUIT RUNS. ALL SPLICES SHALL BE MADE IN JUNCTION, PULL, OR OUTLET BOXES. ALL WIRE SHALL BE INSTALLED IN CONDUIT, WIREWAYS, OR OTHER PROTECTIVE COVER SANCTIONED BY CODES. B. CONDUCTORS FOR LIGHTING AND POWER SHALL BE COPPER, MINIMUM NO. 12 A .16., 600 VOLT. C. NO. 10 GAUGE AND SMALLER CONDUCTORS SHALL BE TYPE THW OR THEN, SOLID CONDUCTOR, UNLESS OTHERWISE INDICATED. D. NO. S GAUGE AND LARGER CONDUCTORS SHALL BE TYPE THAI OR THEN, STRANDED, UNLESS OTHERWISE INDICATED. 7. MG CABLE: 12. FUSES: CONDUIT EXPOSED TO THE NEATI-ER, INSTALLED UNDERGROUND, IN CONCRETE, OR USED FOR SERVICE ENTRANCE SHALL BE STANDARD RIGID CONDUIT (GALVANIZED) WITH THREADED FITTINGS. UNDERGROUND CONDUIT MAY BE POLYVINYL CHLORIDE WITH A DEFLECTION TEMPERATURE, UNDER LOAD AT 264 PSI, OF 75 DEGREES C, AND A TENSILE STRENGTH OF 5200 PSI. JOINTS SHALL BE FLUSH SOLVENT WELDED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE EQUAL TO CARLON POWER AND COMMUNICATIONS DUCT TYPE DB (DIRECT BURIAL). CONDUIT AND FITTINGS SHALL BE PRODUCED BY THE SAME MANUFACTURER. FLEXIBLE METAL CONDUIT (LIQUID - TIGHT) SHALL ONLY BE USED FOR CONNECTIONS TO MOTORS, TRANSFORMERS, AND LIGHT FIXTURES. MAXIMUM LENGTH SHALL BE 6' "_ A MC CABLE SHALL CONSIST OF INTERLOCK ARMORED CABLE MADE OF THREE OR FOUR TYPE THEN STRANDED COPPER CONDUCTORS INSULATED WITH HEAT AND MOISTURE RESISTANT POLYVINYL CHLORIDE (PVC), WITH NYLON OR EQUIVALENT UL LISTED JACKET, PER UL STANDARD 83. THE THI EE CONDUCTORS SHALL BE TWISTED TOGETHER WITH THE COPPER GROUNDING CONDUCTOR, SUITABLE FILLERS, AND WRAPPED IN BINDER TAPE. THE ASSEMBLY SHALL BE ARMORED WITH SPIRALLY WRAPPED INTERLOCKED ARMOR OR ALUMINUM OR GALVANIZED STEEL. B GAEL FS SHALL BE TESTED IN ACCORDANCE WITH UL STANDARD 1566 FOR TYPE MG CABLE AND RATED AT WO VOLTS, 40 DEG. G FOR DRY LOCATIONS AND 75 DEG. G FOR NET LOCATIONS. S. WIRING DEVICES: A WALL SWITCHES SHALL BE SPECIFICATION GRADE, QUIET TYPE, FLUSH TOGGLE SWITCH, RATED FOR 20 AMPS, WITH THERMOPLASTIC COVER PLATES. I) SINGLE POLE: PASS B SEYMOUR #20AGI, OR EQUAL. 2) THREE WAY: PASS g SEYMOUR 4 `20AG3, OR EQUAL. B. RECEPTACLES SHALL BE SPECIFICATION GRADE, DUPLEX, GROUNDING, THREE -WIRE TYPE, RATED FOR 20 AMPS, WITH THERMOPLASTIC COVER PLATES. PASS g SEYMOUR #5352, OR EQUAL C. GROUND FAULT INTERRUPTER. RECEPTACLES (CFI) SHALL BE PASS tr SEYMOUR 2044. DEVICE COVER PLATES SHALL BE AS HEREINBEFORE SPECIFIED. D. ISOLATED GROUND RECEPTACLES (IC,) SHALL BE PASS 4 SEYMOUR 166300, ORANGE COLOR_ DEVICE COVER PLATES SHALL BE AS HEREINBEFORE SPECIFIED. E. RECEPTACLES OUTSIDE BUILDING AND WHERE NOTED AS WEATI-IERPROOF, SHALL BE AS HEREINBEFORE SPECIFIED EXCEPT SHALL BE INSTALLED IN A WEATHERPROOF ENCLOSURE WHICH SHALL BE INTERMATIC #WPIOIOMC OR #WPIOIOHMG DIECAST METAL WEATHERPROOF RECEPTACLE E COVER. COVER. SHALL BE WEATHER PROOF RATED WHILE= IN USE. F. VERIFY DEVICES AND DEVICE COVE2PLATES COLOR WITH ARCHITECT. a. BOXES: A HOT DIPPED GALVANIZED STEEL BOXES- PROVIDE TYPE TO SUIT CONDITIONS FOR INSTALLATION. B. ALL BOXES SHALL BE FLUSH MOUNTED, UNLESS INDICATED OTHERWISE. 10. PANELBOARDS: A. PANELBOARDS ARE EXISTING AND SHALL BE REUSED. PROVIDE ADDITIONAL BREAKERS AS REQUIRED TO CONNECT CIRCUITS AS SHOWN ON THE DRAWINGS. ADDITIONAL BREAKERS SHALL BE THERMAL MAGNETIC, QUICK -BREAK BOLT ON CIRCUIT BREAKERS WITH ONE HANDLE FOR SINGLE OR MULTI -POLE RATINGS AND SHALL BE COMPATIBLE WITH EXISTING PANELS B. COMPLETE EXISTING DIRECTORY AS REQUIRED TO IDENTIFY NEW CIRCUIT, LISTING/ LOAD SERVED AND OTHER PERTINENT DATA II. DISCONNECTS: A DISCONNECTS SHALL BE EXTERNALLY OPERATED, QUICK -MAKE, QUICK - BREAK, SAFETY, WITH PROVISIONS FOR. PAD LOCKING. FUSED AND NON -FUSED DISCONNECT SWITCHES SHALL BE PROVIDED AS INDICATED. B. INDOOR SWITCHES SHALL SE NEMA I AND OUTDOOR SWITCHES SHALL BE NEMA 3R, UNI �r INDICATED OTHERWISE. A FUSES PROTECTING CIRCUIT BREAKER PANELS SHALL BE CURRENT LIMITING UL. CLASS RK -I FULLS WITH 200,000 AMPERES RMS SYM INTERRUPTING CAPACITY. FUSING ELEMENTS SHALL BE SILVER FOR RATINGS ABOVE 60 AMPERES. B. ALL OTHER FUSES SHALL BE U.L. CLASS RK -5, DUAL WITH A MINIMUM TIME - DELAY OF 10 SECONDS AT 500% RATING. FUSES SHALL HAVE CURRENT- LIMITING SHORT -CIRCUIT LINKS AND 200,000 AMPERES RM5 SYM INTERRUPTING CAPACITY. EASING ELEMENTS SHALL BE COPPER_ 13. LIGHT FIXTURES: A WHERE LIGHT FIXTURES ARE MOUNTED IN A LAY -IN CEILING, PROVIDE A MINIMUM OF 2 SUPPORT HIRES ATTACHED DIRECTLY BETWEEN EACH LIGHT FIXTURE AND THE BUILDING STRUCTURE. SUPPORT HIRES SHALL BE A MINIMUM OF 12 GAUGE GALVANIZED STEEL HIRE, SOFT ANNEALED. B. FIXTURES ARE REQUIRED AT ALL LIGHTING OUTLETS SHOWN ON THE DRAWINGS. APPROVED LIGHTING FIXTURE HIRE IS REQUIRED IN ALL FIXTURES AND FIXTURE RACEANAYS. WEATHERPROOF HIRING 15 REQUIRED FOR EXTERIOR FIXTURE ALL PARTS OF FIXTURES AND WIRING SHALL BE IN ACCORDANCE WITH NEC. REQUIREMENTS. G. ALL FIXTURES SHALL CARRY UL AND ETL LABELS. ALL H- UORESGENT FIXTURE BALLASTS SHALL BE HIGH FREQUENCY ELECTRONIC BALLASTS WITH A 'TOTAL HARMONIG DISTORTION" OF LESS THAN 20%, REGARDLESS OF THE NUMBER OF LAMPS CONNECTED TO EACH BALLAST AND SHALL HAVE GEM LABEL. ALL FLUORESCENT FIXTURES INSTALLED SHALL INCORPORATE BALLAST PROTECTION. ALL FLUORESCENT BALLASTS SHALL HAVE AN AUDIBLE NOISE RATING OF "CLASS A" OR BETTER_ ALL FLUOR BALLASTS SHALL. HAVE A POWER FACTOR GREATER THAN q&% WHEN USED WITH PRIMARY LAMP. D. ALL FLUORESCENT LAMPS SHALL BE 3500 K COLOR TEMPERATURE WITH A MINIMUM COLOR RENDERING INDEX (CRI) OF 52. 14. SLEEVES: A. PROVIDE, SET, AND PROPERLY LOCATE PIPE SLEEVES AS REQUIRED FOR T4I5 WORK. B. INTERIOR PARTITIONS: 16 GAGE GALVANIZED STEEL, PACK BETWEEN CONDUIT AND SLEEVE WITH FIRE SAFING AND CAULK AT EACH END WITH FIRE RESISTANT SEALANT. G. ROOF: FROSET OR EQUAL, MANUFACTURED PVC SCHEDULE 40 PIPE SLEEVE WITH WEATHERPROOF SEAL. COORDINATE WITH ROOFING CONTRACTOR AND FLASH AS REQUIRED TO MAINTAIN ROOF WARRANTY. 15. GROUNDING: A. GROUND ALL ELECTRICAL APPARATUS IN ACCORDANCE WITH THE NATIONAL H.ECTRIG CODE (NEC) 250, AND ANY LOCAL REQUIREMENTS. INSURE CONTINUOUS BOND WHERE FLEXIBLE CONDUIT 15 USED. PROVIDE BONDING JUMPER INSIDE ALL FLEXIBLE CONDUIT. B. BOND METAL PIPING SYSTEMS IN COMPLIANCE WITH NEC 250.14. 16. REMODELING WORK: A. DEMOLITION: DISCONNECT, DEMOLISH AND REMOVE ABANDONED FI FCTRICAL MATERIALS AND EQUIPMENT INDICATED TO BE REMOVED AND NOT INDICATED TO BE SALVAGED OR REMAIN. B. EQUIPMENT TO BE SALVAGED: I) DISCONNECT AND REMOVE EXISTING ELECTRICAL EQUIPMENT INDICATED TO BE REMOVED AND SALVAGED. DELIVER EQUIPMENT TO THE LOCATION DESIGNATED BY THE OWNER FOR STORAGE. 2) ALL MATERIALS AND EQUIPMENT DESIGNATED TO BE REUSED OR RELOCATED SHALL BE CAREFULLY REMOVED, AND STORED UNTIL NEEDED FOR REMODELING WORK_ ALL ITEMS SHALL BE RESTORED TO "LIKE NEW" CONDITION WITH RUST OR CORROSION REMOVED, SURFACE PAINT TOUCHED UP OR REPAINTED AS REQUIRED TO MATCH NEW CONSTRUCTION, AND THOROUGHLY GLEANED AND INSPECTED. ANY ITEMS WHICH BECOME DAMAGED BEYOND REPAIR AS A RESULT OF CONSTRUCTION OR DEMOLITION ACTIVITY SHALL. BE REPLACED WITH NEW MATERIAL EQUIVALENT IN EVERY RESPECT. C. DISPOSAL AND CLEANUP: REMOVE FROM THE SITE AND LEGALLY DISPOSE OF DEMOLISHED MATERIALS AND EQUIPMENT NOT INDICATED TO BE SALVAGED. D. PROTECT ADJACENT MATERIALS INDICATED TO REMAIN. INSTALL AND MAINTAIN DUST AND NOISE BARRIERS TO KEEP DIRT, DUST, AND NOISE FROM BEING ".TRANSMITTED TO ADJACENT AREAS. REMOVE PROTECTION AND BARRIERS AFTER REMODELING OPERATIONS ARE COMPLETE. E. PROVIDE ALL ALTERATIONS AND REWORK INDICATED AND /OR REQUIRED FOR THE PROPER INSTALLATION AND OPERATION OF ALL EXISTING Fl FCTRICAL SYSTEMS, INTEGRATING THE NEW AND EXISTING AREAS. LOCATE, IDENTIFY, AND PROTECT ELECTRICAL SERVICES PASSING THROUGH REMODELING AREA AND SERVING OTHER AREAS OUTSIDE THE REMODELING LIMITS. MAINTAIN SERVICES TO AREAS OUTSIDE REMODELING LIMITS. WHEN SERVICES MUST SE INTERRUPTED, INSTALL TEMPORARY SERVICES FOR AFFECTED AREAS. I) ABANDONED CONDUIT 51-IALL HAVE WIRE REMOVED AND SHALL BE CAPPED. ABANDONED OUTLETS IN HALLS OR PARTITIONS SHALL HAVE DEVICES AND WIRE REMOVED, AND SHALL BE COVERED. 2) WHERE EXISTING CONDUITS TERMINATE AT AN EXISTING OUTLET IN A WALL, CEILING, OR FLOOR TO BE REMOVED, DISCONNECT AND REMOVE DEVICE AND WIRE FROM CONDUIT. CONDUIT SHALL. BE GUT BACK AND CAPPED (BELOW THE FLOOR OR ABOVE THE CEILING) 50 NOT TO CREATE AN OBSTRUCTION. PATCH FLOOR TO MATCH EXISTING. 3) HI EXISTING CIRCUITS EXTEND BEYOND THE OUTLET IN THE EXISTING WALL, CEILING, OR FLOOR TO BE REMOVED, FURNISH AND INSTALL NEW CONDUIT AND HIRE TO EITHIBR REROUTE THE CIRCUIT OR FEED THE REMAINING OUTLET(S) FROM ANOTHER Fl FGTRIGAL SOURCE, BUT IN SUCH A MANNER AS NOT TO REVISE Ti-E CIRCUIT. ALL REROUTED CONDUIT SHALL BE APPROVED BY THE ARCHITECT. 4) WHERE EXISTING OUTLETS IN A WALL, CEILING, OR FLOOR TO BE REMOVED ARE ESSENTIAL TO MAINTAIN OPERATION OF OTHER REMAINING OUTLETS, RELOCATE THE OUTLET TO A NEW CONVENIENT LOCATION. EXISTING WIRING DEVICES SHALL NOT BE REUSED, UNLESS OTHERWISE INDICATED. 5) WHERE LIGHTING FIXTURES ARE INDICATED TO SE DEMOLISHED, REMOVE ALL WIRE AND MODIFY THE EXISTING CONDUIT (IF APPLICABLE) FOR THE NEW LIGHTING. ALL UNUSED CONDUIT SHALL BE REMOVED. 6) WHERE A TELEPHONE CIRCUIT EXTENDS BEYOND AN OUTLET IN AN EXISTING HALL, CEILING, OR FLOOR TO BE REMOVED, PROVIDE NECESSARY EMPTY CONDUIT AND NOTIFY THE ARCHITECT WHO HILL REQUEST THE OWNER TO ARRANGE WITH THE TELEPHONE COMPANY FOR NEN WIRING TO OUTLETS THAT REMAIN. 7) WHERE EXISTING CONDUIT AND WIRE RUNS ARE LOCATED IN OR ATTACHED TO AN EXISTING HALL, CEILING OR FLOOR TO BE REMOVED, THEY SHALL BE REROUTED IN EITHER NEW OR EXISTING CONSTRUCTION TO MAINTAIN CONTINUITY OF CIRCUITS UNLESS OTHERWISE INDICATED. 6) CONDUIT SHALL BE CONCEALED WITHIN THE EXISTING BUILDING CONSTRUCTION WHEREVER POSSIBLE, EXCEPT WHERE OTHERWISE INDICATED. q) EXISTING HIRE SHALL BE DISCONNECTED AND REMOVED Hi-EIREVER Hi-EIRE/ER EXISTING CIRCUITS ARE ABANDONED. CODE COMPLIANCE �VED APPROVE JO 1 F ' � No changes shall be made to the scope of work mahout prior a Tukwila Buildin pproval of NOTE: Revisions will r 9 ®�isiNan, squire a new plan submittal and may include additional plan review 1ee SEPARATE PERMIT REQUIRED FOR: ,Mechanical L�J Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION FILE COPY Permit No. D 6 ' 3 1 1 Plan rev*/ approval le ettjact to erron3 and omissions. Approval of construction documerds does not aulhodze the violation of any adopted code or ordnance. of approved Reid and Is �� _ Date: — / =c2 g' City 0fTu a BUILDING DIVISION PEoi -31Z This drawing has been prepared by the Engineer, or under his supervision. This drawing is provided as an instrument of service by the Designer /Engineer and is intended for use on this project only. Pursuant to the Architectural Works Copyright Protection Act of 1990, all drawings specification s, s, ideas and design inch the overall form, arrangement and composition of spaces and elements appearing herein, constitute the original. copyrighted work of the Definer /Engineer. Any reproduction, use, or diseloaure of information contained herein without prior written consent of the Engineer is strictly prohibited. © Copyright 2007 Bob Curry Engineer BOB CURRY Ft 5720 Reeder Shawnee, Ks. 66203 (913)262-1772 ® PROJECT 1 ® PROJECT NUMBER 07436 -17 N PROJECT CONTACT 11-10M TOBEN fitobeneet2dcom ▪ ARCHTECT/DEENoteR JOURNEYS VI WESTRELD SWIMMER 633 SOUTHCENTER SPACE 2305 TUKWi A, WA 98188 STUDIO T2 DESIGN INTERIOR ARCHITECTURE & DESIGN 8010 STATE UNE ROAD SUITE ISO LEAWOOD, KANSAS 66208 PR 91a649.6037 FAX 9iasita _ t11 111 REVISCOS NO. DESORPTION ® DRAW MAGER JAMES A EIGHTY ARCHITECT \%".' FEVEW C:OMENTS EC.¢ ', NOV 3 0 2001 rDERMiT CITE ® DATE 6 NOS 2007 ® DRAWNO TREE MEP SPECIFICATIONS ▪ ssearacesussisimimm RELATED DOCUMENTS: This Drawing b a single part of an integrated set of ConstrucUean Contract Dooments. The General Conditions of the Contract, the Cenerd Requirements, (Melon 1 of the Specifications), applicable h equirements of Division 2 tlru Division 16 Sections of the SpacificatIons, and other Drawbge may apply to the work deecr ed an this drawing. Faithre to Sevier other documents does not relirm the Canthectar from providhg a complete Pmject. COMPLY Willi dl laws, code and ordinanccea of authorities having jurisdiction, and with requirement of the Landlord, if applicable. VEFFY ACTUAL CONDITIONS and dimensions prior to conshruction. Commencement of work constitutes verification and acceptance of existing conditions. CALCULATE AND LhEASURE required dimensions, do not scale the drawings uhdese otherwise directed. APPLICATION of a mutate! or equipment Item to wait installed by others constitutes acceptance of that work, and assumption of responsibility for satisfactory Installation. DIMENSIONS shown are to finish face of a material, urdess otherwise Indicated. DATE 19 NOV. 2007 ME1.0 FAN POWERED BOX SCHEDULE MARK MFGR MODEL N0 INLET SIZE BOX SIZE MAX CFM MIN GFM (I� WS) NOTE *1 GFM RANGE LOSS -SEE NOTE # 2 Fl FGTRIG HEATING COIL ELECTRICAL REMARKS STORAGE FAN CFM KW MBH STAGES VOLT /P /HZ FAN HP VAV -I TRANE VPEF 14" 04 2,200 1320 0.01 320 - 3000 05 1320 125 42.6 2 480/3/60 1/2 - OUTDOOR AIR CALCULATIONS UNIT CLASS SQ. FT. PEOPLE/ SQ. FT. GFM / SQ. FT. GFM/ PERSON GFM VAV -I RETAIL SOO - 0.3 - 240 STORAGE Seri - 0.15 - 134 - Hi TRM 0.13.0. RG-I TOTAL 3 374 O.A. / 2,200 S.A. =1196 - VERIFY EXISTING LANDLORD HVAG UNIT PROVIDES MINIMUM 17% OUTDOOR AIR EXHAUST FAN SCHEDULE MARK MFGR MODEL GFM EXTERNAL STATIC P. IN. HS. RPM ELECTRICAL FAN TYPE REMARKS VOLT /O /HZ PWR EF -I GOOK SC - I24 75 0.25 000 120/1/60 641/4 CEILING EXH. - Hi TRM 0.13.0. RG-I 50F - 24 "x48" DIFFUSER SCHEDULE MARK MFCR MODEL NECK SIZE FACE SIZE FINISH REMARKS SD -I TITUS PAS/3 10 "P 24 "x24" WHITE - 5D -2 j Hi TRM 0.13.0. RG-I 50F - 24 "x48" FLEXIBLE DUCT CONNECTION FAN POWERED VAV SOX LOW PRESSURE SUPPLY AIR DUCT. SEE FLOOR PLAN FOR SIZES. ELECTRIC HEATING GO IL. RA SOUND BOOT MINIMUM 4 INLET DIAMETERS OF STRAIGHT DUCT FOR AiR VELOCITY MEASUREMENTS. INSULATED FLEXIBLE DUCT, MAXIMUM 3' LONS LANDLORD SUPPLY AIR DUCT FAN POWERED VAV BOX DETAIL SCALE: NONE 2. FANS SHALL NOT EXCEED SGHEDUL FD RPM. 10. PROVIDE (FUSED) DISCONNECT FOR EACH UNIT. MEGHAN I GAL GENERAL NOTES I. COORDINATE ALL WORK WITH 0T11ER TRADES AND EXISTING CONDITIONS AS REQUIRED TO PROPERLY INSTALL ALL SYSTEMS AS INTENDED, WITHIN THE CONFINES OF THE SPACES AVAILABLE, AND WITHOUT INTERFERENCES. 2. THIS CON I KAGTOR SHAT I PERFORM ALL WORK INDICATED AND /OR AS REQUIRED FOR THE PROPER INSTALLATION AND OPERATION OF THE MECHANICAL SYSTEMS. 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF DIFFUSERS. 4. INSTALL ALL DUCT, PIPE, ETC. AS HIGH AS POSSIBLE. 5. DUCT SIZES SHOWN ARE ACTUAL SHEET Miz I AL SIZES AND INCLUDE A I/2 INCH ALLOWANCE FOR DUCT LINER WHERE APPLICABLE. O. PROVIDE FLEXIBLE CONNECTION BETWEEN DUCTWORK, VAV UNIT, EXHAUST FANS, AND OTHER MOTORIZED EQUIPMENT. 7. NO DUCT OR PIPING SHALL BE ROUTED OVER THE TOP OF FI FGTRIGAL PANELS. S. REFER TO ARCHITECTURAL 4 STRUCTURAL DRAWINGS FOR REQUIREMENTS FOR SUPPORTING PIPING, EQUIPMENT, ETC. FROM THE STRUCTURE. PROVIDE ADDITIONAL STEEL AS REQUIRED TO PROPERLY SUPPORT SYSTEMS FROM THE STRUCTURE. 0 1. VERIFY EXISTING CONDITIONS. IN THE CASE OF DISCREPANCIES, CONTACT THE ENGINEER OR ARCHITECT FOR DIRECTION AS NECESSARY. 10. IF APPLICABLE, PROVIDE NECESSARY COMPONENTS FOR INTERLOCK WITH LANDLORD'S ENERGY MANAGEMENT, BUILDING MANAGEMENT, AND /OR SMOKE CONTROL SYSTEM. II. NOTHING SHALL BE DIRECTLY ATTACHED SLAB OR ROOF DE - OVE. TENANT SHALL MAINTAIN MINIMUM 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM FOR AIRFLOW BACK TO LANDLORD HVAG UNIT. NOTES: I. PROVIDE CEILING GRILLE, INTEGRAL BACK DRAFT DAMPER, AND NON -FUSED DISCONNECT FOR EF -I. NOTES: I. ALL BOXES SHALL BE PRESSURE INDEPENDENT. 2. MAXIMUM WIDE OPEN STATIC PRESSURE DROP. 3. ALL BOXES SHALL HAVE A MINIMUM OF 4 INI FT DIAMETERS OF STRAIGHT DUCT AT BOX INLET. 4. REFER TO SPECIFICATION FOR TEMPERATURE CONTROL SQUENGE. 5. ALL UNITS SI TALL BE PROVIDED WITH ACTUATOR WHICH HAS RE DIAPHRAM. 6. MAX. END DISCHARGE SOUND POWER LEVEL IN 3RD OCTAVE BAND a1.0" W.S. PRESSURE DROP, IN ACCORDANCE WITH 1.5.0. STANDARD #521q, 1.5.0. STANDARD #3741 $ ARI-ADC. 1. ACOUSTICAL MATERIAL SHAI 1 BE 3/4" DUAL DENSITY COATED TO PREVENT AIR EROSION $ MEETS REQUIREMENTS OF UL 181 $ NFPA -qOA. 8. PROVIDE I" THICK THROWAWAY TYPE FILTER WITH HOLDIN6 FRAME ON RA INLET, VIBRATION ISOLATORS 4 NON -FUSED DISCONNECT FOR EACH UNIT. a. PROVIDE 24 VOLT CONTROL TRANSFORMER WALL MOUNTED SINGLE STAGE THERMOSTAT FOR EACH UNIT. 0 0 0 0 0 MECHANICAL PLAN NOTES: SUPPORT UNIT FROM STRUCTURE AS REQUIRED. LOCATION OF DUCT MOUNTED SMOKE DETECTOR. SMOKE DETECTOR TO BE FURNISHED BY DIV. 16. SUPPORT UNIT FROM STRUCTURE AS REQUIRED_ PROVIDE ADDITIONAL STEEL BRACING AND VIBRATION ISOLATION AS REQUIRED. CONNECT 6 "0 EXHAUST DUCT TO LANDLORD PROVIDED EXHAUST DUCT STUBA AS REQUIRE. VERIFY EXACT LGOATION OF EXISTING DUCT PRIOR TO INSTALLATION OF ANY DUCTWORK. TRANSITION AND CONNECT 14 "0 SUPPLY AIR DUCT TO LANDLORD PROVIDED DUCT BRANCH AS REQUIRED. VERIFY EXACT LOCATION OF LANDLORD DUCT PRIOR TO INSTALLATION OF ANY DUCTWORK. RG -I SD -I 350 GFM VAV- N 10 u MECHANICAL FLOOR PLAN SCALE: I /4" = I' -0" zi_11•■•=111 32 "x14" 6 "(1 Y \1— S.A. R.A. EXH. BRANCH DUCT SPIN IN WITH VOLUME DAMPER ROUND FLEX DUCT. 5' MAX. LENGTH DIFFUSER DIFFUSER DETAIL SCALE: NONE MEGHANIGAL SYMBOLS NEW SUPPLY DIFFUSER NEW RETURN AIR GRILLE EXHAUST GRILLE THERMOSTAT, MOUNTED AT 48" AFF DUCT-MOUNTED SMOKE DETECTOR NEW DUCTWORK SIZE OF RECTANGULAR DUCT SIZE OF ROUND DUCT MANUAL VOLUME DAMPER FLEXIBLE DUCTWORK FLEXIBLE CONNECTION TO FAN FLOOR PLAN NOTE DESIGNATION SUPPLY AIR RETURN AIR EXHAUST AIR TRANSITION IN DUCT SIZE R EVI EW E D F , -�- _I CODE COM APPROVED JAN l (; 2000 City Of Tukwiiia ILDING DIVISION This drawing has been prepared by the Engineer, or under his supervision. This drawing is provided as an instrument of service by the Deer /Engineer and is intended for vse on this project only. Pursuant to the Architectural Works Copyright Protection Act of 1990, all drawings, specifications, ideas and designs, including the overall form. arrangement and composition of spaces and elements appearing herein, constitute the original, copyrighted work of the Designer/Englneer. Any reproduction. use. or disclosure of information contained herein without prior written consent of the Engineer is strictly prohibited. 0 Copyright 2007 Bob Curry Engineer BOB CURRY �NCaIN��Fi 5720 Reeder Shawnee, Ks. 66203 (913)262 -1772 1 ® PROJECT ® cAI_ NOTES MI REASONS NQ DE;TION 9 DRAWtIO NUMBER JOURNEYS JY 789 WESTFELD SOUTHCENTER 633 SOUTHC ENTER SPACE 2305 TUCWLA, WA 98188 ▪ PROJECT NUMBER 07436 -17 ® PROJECT CONTACT THOM TOBEN tftdber*st2dcom ® ARcHnEceIr/DE JAMES A EIGHTY ARCHTECT F{EV1eN COMMENTS RECEIVED NOV 3 0 2007 PERMIT CENTEF ® DATE 6 NOVBABER 2007 e DRAWS TITLE MECHANICAL FLOOR PLAN STUDIO T2 DESIGN INTERIOR ARCHITECTURE & DESIGN 8010 STATE LINE ROAD SUITE 180 LEAWOOD, KANSAS 66208 FI-t 913649 17 FAX: 913648.7111 RELATED DOCUA EN1a This Drawing b a single part of an integrated set of CAnabucttan Contract Docu nada The General Conciliate of the Contract, the Generd Requirements, (Division 1 of the Sp aticns), applicable requirements of Dhvisim 2 thru Make 16 Sections of the Spedftcatiane, and other Drawings may apply to the work described an this drawing. Failure to review other documents does not refleve the Canbaclnr from padding a =plate Project. COMPLY V1111 dl Taws. code and ordinances of authorities having jurisdiction, and with requirement of the Laniard, If applicable. IOW( ACTUAL CONDI110NS and dimensions prior to construction. Commencement of week constitutes vwifcation end acceptance of existing conditions. CALCULATE AND I4EASURE required dimensions, do not soda the drawings unless otherwise directed. APPLICATION of a material or equipment item to work installed by others constitutes acceptance of that work, and assrsnptian of responsibility for satisfactory installation. DIIffNSIONS shown ore to finish face of a material, unless othees indicated. DA1E 19 NOV. 2007 M1 PLUMB I NS FIXTURE SCHEDULE : RAH HOT WATER HEATER: AO SMITH #ELSG -20S, 20 GALLON STORAGE, 120 VOLT, 2500 WATT ELEMENT, ASME TEMPERATURE AND PRESSURE RELIEF VALVE. MB MOP BASIN: FIAT, #MSS -2424, MOLDED STONE MOP BASIN, 2" DRAIN, 24 "x 24" BASIN, #E -Ti -AA VINYL BUMPER GUARD, #830 -AA FAUCET, VACUUM BREAKER, INTEGRAL STOPS, HALL BRACE PAIL HOOK, #832 -AA WALL BRACKET WITH 30 HOSE. ET HOT WATER EXPANSION TANK: AMTROL, #ST -5, 2.0 GALLON EXPANSION TANK WITH DIAPHRAGM. LI HANDICAP LAVATORY, WALL HUNG: TOTO #LT307, 20"x 18 ", VITREOUS CHINA, FRONT OVERFLOW, DELTA #501 FAUCET WITH SiNGLE METAL LEVER FAUCET, OFFSET GRID ELBOW DRAIN AND I -1/4 TAILPIECE, CHROME PLATED GAST BRASS P -TRAP WITH GLEANOUT (MOUNTED PARALLEL WITH WALL), CHROME PLATED LOOSE KEY ANGLE STOPS AND RISERS, FLOOR MOUNTED CONGEALED ARM LAVATORY SUPPORT, INSULATE EXPOSED DRAIN, WATER SUPPLIES, AND VALVES WITH PROWRAP SEAMLESS MOLDED CLOSED CELL VINYL INSULATION. HWG HANDICAP WATER CLOSET: TOTO, #GST744SL, "DRAKE CLOSE COUPLED TOILET", lb GALLON FLUSH, 16 -1/2" HIGH ELONGATED BOWL, FLOOR MOUNTED, FLOOR OUTLET, TANK TYPE, VITREOUS CHINA, SIPHON -JET ACTION, #SG514 OPEN FRONT SEAT WITH CHECK HINGE AND LESS COVER, CHROME PLATED ANGLE STOP AND RISER. HANDLE ON HIDE SIDE OF FIXTURE. MV MIXING VALVE: WATTS, *USG-B, THERMOSTATIC CONTROLLED MIXING VALVE, BRONZE BODY, LOCKED TEMPERATURE ADJUSTMENT CAP (VANDAL RESISTANT), COPPER ENCAPSULATED THERMOSTAT ASSEMBLY WITH BRASS SHUTTLE, STAINLESS STEEL SPRINGS, INTEGRAL CHECK VALVES ON HOT AND GOLD INLETS. FD FLOOR DRAIN: JR SMITH, #2005 -A, GAST IRON FLOOR DRAIN WITH ADJUSTABLE TOP AND 6" NIKALOY STRAINER. PROVIDE WITH TRAP PRIMER CONNECTION. PLUMB I NS E I XTURE BRANCH P I P I NS SCHEDULE WATER CLOSET (TANK TYPE) LAVATORY FLOOR DRAIN MOP BASIN NOTE: INDIVIDUAL VENTS FOR FIXTURES ON PLANS AND RISER BEEN INCREASED WHERE HORIZONTAL VENT LENOTH 15 IN EXCESS OF THE MAXIMUM DISTANCE INDICATED BY THE CODE. RPZ CONNECT TO EXISTING CONNECT TO EXISTING 4" 1NATER SUPPLY ALL PIPE IS SIZED BASED ON A 10 FPS 18 QMUM. FIXTURE QUANTITY GIN FU TOTAL FU HW FU TOTAL FU ^IATER CLOSET FIXTURE WASTE LAVATORIES I MOP BASIN I CONNECT TO EXISTING CH STUB 8 CV{ FlJ =6GPM 6 GPM REQUIRES 1/2" PIPE 3.0 HW FU = 2 GPM 2 GPM REQUIRES 1/2" PIPE 3 I I 3 / . y / it • MB LI 12 HWG HOT t GOLD SLATER 4" FGO 2 " 2 MB 1 I 11 A 4 " I -1/4" 2" 2" 5 15 15 IS 15 211 � FD 4 11 ` 1 VENT 2 " 1 -1/4" 2 " 2 " 819.) SCALE: NONE WG� GW 1/2" 1/2" 1/2" PLUMB I NS DRAINAGE GALGULATI ONS FIXTURE QUANTITY FU TOTAL FU WATER CLOSETS LAVATORIES FLOOR DRAIN MOP BASIN 6 I I I 2 I 3 6 2 3 TOTAL FIXTURE UNITS (FU) 12.0 FU FOR F 2" VENT IS ADEQUATE FOR 12 FU 5" WASTE IS ADEQUATE FOR 12 FU 11 For Health Hazard Applications Series 009 REDUCED PRESSURE ZONE DACKFLOW PREVENTER S12es•'1'•3 (8•50mm t1 F' rd'.a;rrr ;Imo Bark'rI:.. d'• , .I , wl • . , p �1.�t ^LUrlr vn.I9 s.1p M'+�s man uu +ru vnllucdoaa, 1 1r: , r.p•r b mr..::.P walt„,n•nrnav leryl 1•rr. a'vs+mr ■• .;1 .Inn PS • M: prrFcr.fly .1 mp I1.: .1 r 'I• wr fir,' 'r pip! I •nvnnm n tn. r" a ,rm ✓.. ammo Fe, ne ,1 „e'a .pear••, mrtr n.mb w1 ,:•, 1,311I0 • il Pt .31, I1 , ,np.:x I ! il!',: x:1 •.1 anti t rS aas'r main l a r:' a n' lY+%Y".Irit air, ,r ' I ,r;'r rrrl'.r 11,x1', tltr +l ler nannl FEATURES • Smote access onto& and madder check ounswtka• for ease or marnmPadre • lost CRby all Internals lmnredlrhly aeeesatle • Captured sprigs Ise safe maintewance • imam' rebut halve tar ladur:ed leSlateikn Clearances • Repeteable seats Poe econamlcal repaG • Reece body ern61rr.c11113 IN dmallllrty ' 13 2 . 16.50 , 4.1 • Fated epmry Ceded Coal nod body 1' " Bed 3'155 Nom) • Bolo ,ales tad cods sometime ttomed t"11 r la Mail • I arp, hurry passages piperdes into prasauro imp • compact. spice Sa"lold design • No special tools ',eared Ice sonatas; SPECIFICATIONS • ■rsotv ra n fk 33r a p.ae l 4 lm I ' I . e I .S h 51,1, , s•. rI 1 Ilol L. b H •1 lrr+mr rue .I 1 r d i F r, I e T t. � 1 1 t L , I d.la I •• "t are u rx�e 1• .al L r „d • !! tx a Ir n d r. 1 •. , n r .tn. 1 "I t.. a I' •h Jl to r i 1 5 1 4 ; Jna I'M vsret , MII ,1 ..1.4 1 .Ice' t "ht". eel nr . + rr, rl u... klarua1 bar F save.' A5.5F 5 re5•F:. t' ,Vi. •,•:, ',t'1 ".a FLa t 4Yd1' uo,r av0- 0c.1,c Awn fir low 'Does not indreate approval status. Refer to Pays 2 for approved sties 8 models. OO9M2OTHC (21 Tell Ball Type Copt Test Yock3 alt] 3 Snored ChM teal sr L / Malabo Assy Conk NO4 1 Avai table, VI /Latttil3w Insulated Enclosures. - .a.e rn.omv.ro., sera: for cr ES. C -T. \war`r weaur on taus..,_,,,% Pw[don . lately a 133 .. AVAILABLE MODELS - V. to 2" Suffix: aT • 'Holt] ouartat turn. lull par Lr Bern sealed ball valve Shutoffs S • with bronze shunter LF • without shutoffs AlT • elbow btlwa5 la 362 'MOO la.', .2 °miff 120•511mm onry PC • will internal pola'mer Coatiig LH • with lacking hands ball valves (open pasltonl SH • with stalnl5SS vet; bail valve MO:[m HC • 'rdlh E'. + edeYptlet ere mwanf 5ten r7 vsl,5 Prer,s. C' nth integrated strainer and check ( • b Y (20•75mm Only) U • union roam :pitons AVAILABLE MODELS - 21/2" to 3' SIf Ir IRS • wrth NRS roslllem sealed gate valve shill/11S OAST • with OSAY reoUlenl sealed gate valve ahut011s S•FDA - min FDA epoxy cnat8d siratner 07•FOA • with FDA apnxy coated ts5 ■0'1 ba0 vain shutoffs LF • olhota shmoh valves S • with n041 epoxy 551T5 nag as Piano Arne 0 0' gap is na te55O (see h S AGIeC Wien rns:alt MATERIALS - 'A U to 2" 6ronte hody rnrS:ruttlOf, oIK3ne rabbet dI C maM'ral Rr me'LrsI 4ai accord check plus Ifw relied fart" R,httear•e paryrner churl seats Is, last and samara wicks Remo'rab!2 elamless stilt raw Yal:'e sat SIa ho, `.1ad• rover Dells Sta,datily turMSllad item HP1 briny conrtateons r at aplmral bran,, anion veal ela need L 00,010115 Spahr 0r511, L 2'f(1h-50ntmF 00951 a !u Moots n n Quartet turn Ia pate 1e51een1 seasen, he0 • ead.v esak9 MATERIALS - 21/2" to 3• • tFOA nppraredi Fpa•y comet.' ran uttbonr, .r.1h Ltan,e seals • Rake( WALE wen slatraass Ohl sear aid I• • Proo:• body ball raOe lest Corks PRESSURE - TEMPERATURE Series 009 'I" • 2" I 1-50nlm) as sultable Id suppF* 00550 up Its %5091 ha.sl Witt tempered.: 33 F 180 I I.7 "Cm Cr Stgas 2W and t68- 30rrana)aresditah sI'th a 175'151 It2 rars1 iod pate tempnawre at 11 147 C) carllryduy. I Rd'F (66"C) Interrttielem STANDARDS USC Man t6F EDI Ether ss'a Ito 1013 A5 Ih C5'1 CSA B64 IAPIC Doe No 1503 1'0001 col luAluale amount status Sea bat= for appaoded models. 1M PO AT AYr t oni �s F4 iniwR'aiuu.' Air Gaps and Elbows Sin, I � Iwanm gNiht kph BNy Ier 909 ops rP Is win ms aid_ ■d �-} one tl➢3 Si[i1 u N In - , 3ti s see ore 9N.[ a_ opa•+'o>•riad ^. t1 .MK6S n'alas'y aS ��dl�a } Ii I ti 1; P os.1,i r[rah;• I TY59M APPROVALS ASFF ANNA ESA. IAPMO ADD( v Y1 Ds Ins Folotilatm tot Crow Conned Conical and Ol'dratd•t Rossilla n the Uldeersdl el SoaMom Caaflxs" Approval nludpl9 Ri ACT PC U. NRS OSr OS t lllf ad3.ann 055 ggaat,, rtwdels rutty) i w .vo e. 90VFr'" • + I Q I4 1 a Gages 0 Ito R5 iV 74 15 , : elv saaLL a Y: ','dre.t: 00110-1.1 C I ; _ -. _ - - rlr~�aWaYl f suit 1 Olevad :it so 431 Dlmeo =Wtm (appro Grate) Slut OH Al � SC C Model ft]. mph Fn, kl. I rum In. L LIMY 22 15 16!0 419 4, 1- 121 3i2 t]9 . 1J003M20T + 20 13•, 345 , 127 3v, y5 u0091.1201 1 25 1711 441 S 140 3.0 J 79 00091d201 I . 52 247, l 522 7 197 4 i IOp U0994)201 1v OS'. . 40 648 7t i 297 4r'' 1LS 002351207 2 50 27 1 695 I rat 197 DIMENSIONS and WEIGHT - Y to 2" U SBS DH I A c 0 I Made) et] t I Poll h. I it]. t mph I h. ( mm j1,_811.. USD9 5 T i. f 20 U 13✓a t 33 3 4 121 2!t 0pSIt00T 25 t 13. 333 3 9 is S,+ 130 9'r 132 25t A0T rd 45 1 I 0009M2 8 5cl 390 4 100 87 147 h. , 197 L 39 YT09t12 Ciii 2 I 50 19La � 489 ( 4V, 108 Br. i 213 rM � 213 31 HW 1/2" 1/2" 15 I5 15 15 3.0 FU FiRE PROTECTION NOTES= I. THE EXISTING SPACE IS PROTECTED WITH AN EXISTING HET PiPE SPRINKLER SYSTEM. RELOCATE AND PROVIDE ADDITIONAL SPRINKLER HEADS AND PIPING AS REQUIRED FOR THE NEW CONSTRUCTION. SPRINKLER HEADS IN FINISHED CEILINGS SHALL BE CONGEALED POP -UF COVER TYPE. SPRINKLER HEADS IN ROOMS WITHOUT CEILINGS SHALL BE UPRIGHT BRASS TYPE HEADS. 2. SPRINKLER WORK SHALL BE PERFORMED BY A SPRINKLER CONTRACTOR PRE- APPROVED BY THE LANDLORD. 3. REFER TO THE ARCHITECTURAL DRAWI FOR NEW WALL CONSTRUCTION. 4. SPRINKLER PIPING SHALL MATCH EXISTING. 5. SPRINKLER SYSTEM (SHOP DRAWINGS) SHALL BE APPROVED BY THE LOCAL FIRE AUTHORITY AND LANDLORD'S INSURANCE CARRIER PRIOR TO START OF WORK. 6. SPRINKLERS SHALL BE SUPPORTED FROM BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECKS ABOVE. - 7. TENANT SHALL INSTALL A VANE TYPE HATERFLOR DE I EGTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION TO LANDLORD'S MAIN, WHICH IS CONNECTED TO LANDLORD'S FIRE ALARM SYSTEM. 0 0 PLUMBING ISOMETRIC DIAGRAMS PLUMBING GENERAL NOTES: I. INSTALL ALL PIPE, ETC. AS HIGH AS POSSIBLE. 2. COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS AS REQUIRED TO PROPERLY INSTALL ALL SYSTEMS AS IN I ENDED, WITHIN THE CONFINES OF THE SPACES AVAILABLE, AND WITHOUT INTERFERENCES. 3. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF FIXTURES. 4. REFER TO ARCHITECTURAL STRUCTURAL DRAWINGS FOR REQUIREMENTS FOR SUPPORTING PIPING, EQUIPMENT, ETC. FROM THE STRUCTURE. PROVIDE ADDITIONAL STEEL AS REQUIRED TO PROPERLY SUPPORT SYSTEMS FROM THE STRUCTURE. 5. VERIFY IF FLOOR IS SLAB ON GRADE OR STRUCTURAL SLAB. IF SLAB ON GRADE, SAWGUT AND PATCH TO MATCH EXISTING FLOOR AS REQUIRED. IF STRUCTURAL SLAB, LOCATE PIPING IN CEILING VOID BELOW. ALL PENETRATIONS OF FLOOR SHALL BE IN ACCORDANCE WITH MAI 1 REQUIREMENTS. ALL SAWGUTTING AND GORE DRILLING SHALL BE PERFORMED AS REQUIRED BY LANDLORD. 6. NO PIPING SHALL BE ROUTED OVER THE TOP OF ELECTRICAL PANELS - 7• ALL MATERIALS EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE - DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84. S WATER HAMMER ARRESTORS AND !i IUT OFF VALVES SHALL BE INSTALLED AT ALL PLUMBING FIXTURES. PLUMBING PLAN NOTES: CONNECT 2" VENT TO EXISTING LANDLORD PROVIDED VENT STUB AS REQUIRED. VERIFY EXACT LOCATION OF VENT STUB PRIOR TO INSTALLATION OF ANY PIPING. CONNECT 3/4" CW TO EXISTING CH PIPE STUB WITH SHUT OFF VALVE AS REQUIRED. VERIFY EXACT LOCATION OF EXISTING PIPE PRIOR TO INSTALLATION OF ANY PIPING. INSTALL HOT HATER HEATER ABOVE MOP BASIN. SUPPORT UNIT FROM STRUCTURE AS REQUIRED. PROVIDE DRAIN PAN WITH 5 /4" PIPE DOWN WALL zt TERMINATE AT MOP BASIN WITH AIR GAP. PROVIDE ASME RELIEVE VALVE WITH FULL SIZE DISCHARGE PIPE. RUN DOWN HALL AND TERMINATE AT MOP BASIN WITH AIR SAP AS REQUIRED. CONNECT WASTE TO EXISTING WASTE STUB AS REQUIRED. VERIFY EXACT LOCATION, ELEVATION, AND DIRECTION OF FLOW OF EXISTING PIPES PRIOR TO INSTALLATION OF ANY PIPING. INSTALL RPZ BACKFLOW PREVENTOR ABOVE MOP BASIN AS REQUIRED. ROUTE DRAIN FROM RPZ TO MOP BASIN WITH AIR GAP AS REQUIRED. RPZ TO BE WATTS SERIES UOOQQT, 3 4." UNION CONNECTION OR EQUAL. II FGO H J _L PLUMBING SYMBOLS -I I- SOIL AND HASTE PIPING BELOW GRADE SOIL AND HASTE PIPING ABOVE GRADE SANITARY VENT PIPING ABOVE GRADE SANITARY VENT PIPING BELOW GRADE DOMESTIC GOLD HATER PIPING DOMESTIC HOT WATER PIPING EQUIPMENT DRAIN LINE PIPING TURNING DOWN 0 PIPING TURNING UP TEE TOP CONNECTION UNION RPZ BACKFLOW PREVENTER FLOOR GLEAN OUT HALL GLEAN OUT FLOOR DRAIN VALVE CHECK VALVE BALANCING VALVE MATCH MARKS ON PLUMBING RISER DIAGRAM V - -V- -- 1 1. FGO 0 WGO F1'0 - 0 I REVIEV1�Ei� � CODE COMPLIANCE APPROVED .101 6 City Of Tukwila ILD NG DIYISI • 'NCOMPLETE P&O" 3z2. This drawing has been prepared by the Engineer, or under his supervision. This drawing is provided as an instrument of service by the Designer /Engineer and is intended for use on this project only. Pursuant to the Architectural Works Copyright Protection Act of 1990. all drawings, speoifications, ideas and designs. including the overall form, arrangement and composition of spaces and elements appearing herein, constitute the original, copyrighted work of the Designer/Engineer. Any reproduction. use. or disclosure of information contained herein without prior written consent of the Engineer is strictly prohibited. © Copyright 2007 Bob Curry Engineer BC JAN 00 o� z PERMIT CENT BOB CURRY 5720 Reeder Shawnee, Ks. 66203 (913)262 -1772 • PROP ■ PROJECT i&i 07436-17 • PROJECT COMPACT THOM TOBEN tltoben«st2doom ■ ARCHITECT/D • • GENERAL NOTES ■ REV1810NB NQ DESCRPTICN 1 2 JOUR EYS JY 789 WESTRELD SOUTHCETR'ER 633 SOUTHCENTER SPACE 2305 TUKWLA, WA 98188 REVS • CCIVIVENTS CITY CAMI EVTS • DATE 6 NOVEMBE 2007 • DRAWtIQ TITLE PLUMBING FLOOR PLAN ■ DRAV MAGER JAMES A UCHTY ARCHITECT STUDIO T2 DESIGN INTERIOR AFCHfTECTURE & DESIGN 8010 STATE UNE ROAD SUITE 180 L EAWOOD, KANSAS 66208 P1-I 91a649.6037 FAX 913x648.7111 MEM S WIM INN 11111 � � ° 2 RELATED DOCUAENTa This Orating is a single part of an integrated set of Construction Contract Documents. The General Conditions of the Centred. the General Requdremeate. (Division 1 of the motions), applicable requirements of Division 2 thru DiMsion 16 Sections of the Spedficatlwle, and other Orawinge may apply to the work desalted on this drawing. Falnre to reMew other documents does not relive the Contractor from prinking a can riete Project. COMPLY MATH ail laws, code end ordinances of autharit es having jurisdiction, and with realrement of the Landlord, if applicable. VERIFY ACTUAL COMMONS and olmanstene prior to construction. Commencement of work constitutes %erificatien and acceptance of existing condition& CALICULATE MID MEASURE required dimensions, do not scale the drawhgs unless otherwise directed. APPLICATION of a material or equipment item to work hstdled by others constitutes acceptance of that wait, and assumption of responsibllty for se tiafactcry instoilatlon. DIMBIS1ONS shown are to finish face of a material, unless Amiss indicated DATE 19 NOV. 2007 12 DEC. 2007 P1