Loading...
HomeMy WebLinkAboutPermit PG07-334 - WESTFIELD SOUTHCENTER MALL - GUESSGUESS 467 SOUTHCENTER MALL PGO7-334 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 Citof Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 467 SOUTHCENTER MALL TUKW GUESS 467 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA PLUMBING /GAS PIPING PERMIT LAUREN CHASE 626 C ADMIRAL DR, PMB STE 120 , ANNAPOLIS MD Contractor: Name: HORIZON RETAIL CONST INC Address: 1516 S GREEN BAY RD , RACINE WI Contractor License No: HORIZRC072N5 $10,000.00 $142.50 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet FIXTURE TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 04/15/2009 DESCRIPTION OF WORK: INSTALLATION OF NEW LAVATORY, WATER CLOSET, AND FLOOR DRAIN. INSTALLATION OF NEW PIPING AS REQUIRED TO CONNECT TO EXISTING SERVICES. Phone: Phone: 410 544 -1700 Phone: PG07 -334 04/18/2008 10/15/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 1 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 1 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 1 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 PG07 -334 Printed: 04 -18 -2008 Permit Center Authorized Signature. The granting of this permit does Signature: Print Name: L� doc: UPC -10/06 City cif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO7 -334 Issue Date: 04/18/2008 Permit Expires On: 10/15/2008 Date: 0 l i W I hereby certify that I have read and -x• ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • wi , whether specified herein or not. otgresume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or tl jrman G plumbing /gas c o ork. authorized to sign and obtain this p piping permit. Date: --/C, 8' This permit shall become null and void if the v,6rk is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -334 Printed: 04 -18 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: GUESS 1: ** *PLUMBING AND GAS PIPING * ** doc: Cond -10/06 tirr/ fir'' City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 467 SOUTHCENTER MALL TUKW PERMIT CONDITIONS 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. T: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PGO7 -334 ISSUED 12/11/2007 04/18/2008 PG07 -334 Printed: 04 -18 -2008 City of Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: 4 PG07 -334 Printed: 04 -18 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citulatila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: N EA/ Ca 1ih14VkY �t� Suite Number: /S4S Floor: Tenant Name: VE•..13 New Tenant: 1g Yes ❑ ..No Property Owners Name: M/CSTF ICL'E) Go0.'liaRa'r Mailing Address: //bat W 14,51114E SLvD CONTACT PERSON - who do we contact when your permit is ready to be Name:1A'1 15'FP /tjh/(r4 C Mailing Address: 1 103T.IaT 'P s9•fie ""D 0.. i754-1t'c- e/7 trsnALezniutt (coin E -Mail Address: T KeS c ISCL tw/E+ @eonCA51 - . sJE T Company Name: E1o 'DE Si 4 Gigot,' Mailing Address: J/SS oet v - rrE ExEccer ye• 'PAQbcWA s� • loo Contact Personi AviE'• GLsiEk E -Mail Address: G4NuE'Q434'1 . ,JET Company NameLA.l °ALL A. 1VELSo,1 Mailing Address: BOIL it E pcQ 'RV. Contact Person:1A,IOACL A. AIELSde,► E -Mail AddressikA (pf"/E4So..1 Q ltoc., • . to Q: Applications\Forms- Applications On Line 3 -2006 - Permit Application doc Revised. 9 - 2006 bh Building Permit No. Mechanical Permit 7 Plumbing/Gas Permit No. Public Works Permit No. or o ce use on trl 2 Q 'OM u ' King Co Assessor's Tax No.: o o l Lo.S A.J661ES City ued State Day Telephone: 2c( • 38'I • 77 i 9 .1"171. Le' cait.e 'PA /6803 City State Zip Fax Number: 8 4 ( • 610 • 14443 GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: ARCHITECT, OF RECORD = All plans must be wet stamped by Architect of Record _-T, 43u a City State /MO State Day Telephone31L1- 721. Fax Number: 314' 72I •.6 3 4L/ Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer o K5 (06 208 teiVEXA City State Zip Day Telephone: 9/3 - 22 • S!j"t., Fax Number: 0 1'I 3 - 122 - $ Zip 63 132 Zip Page 1 of 6 r. r IUILDING PERMIT INFORMATION !- 206 -431- 3670 Will there be new rack storage? Yes PLANNING Q:'Applications\Forms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Valuation of Project (contractor's bid price): $ 300 , Do0 Existing Building Valuation: $ Scope of Work (please provide detailed information): Ex 1S r $/ S'Ace' To 'SE F,,/ISME /J 7 A CcJES 'Q %rAIL STo2e T•EWA,JTS SQAe W'IL ZWGZas ®E NEW TART IT144 T =4 icL F /At IS , 'Dcis 4S , -re tor Acts" -z.Ai - r ALLATIO,I or ItEst/ SALV / 3" "MG k. F • xru & .i Axle //vA ide All Building Areas itnSquare Footage Below DIVISIO . Addition to Existing ctuie `. f 4 ❑.. No If yes, a separate permit and plan sub I will be required. Single family building ' • tprint (area of the foundation of all structures, plus any decks over 18 inc - s and overhangs greater than 18 inches) *For an Accessory d elling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: or area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: A ir Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flanunable, combustible or hazardous materials in the building? ❑ Yes No If "yes ; attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Sa ety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Fixture Type: Qty ' Fixture Type: _ -Qty Fixture Type: QtS' " Fixture Type: YP • Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 1 Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory • 1 Water Closet 1 Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas ' F FIUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ /o , 00 o Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): r .Js iAtc A sJ as NE i LAVA &V WAr L ccasce AAl IC4CUL4 ( Moe., T rAItu►TtaAu of .46W ''1 fiIIG A3 AEA $1,v t` Cc' A/4IE<r 1 Gx (ft 144 S'EL ice 5. Building Use (per Intl Building Code): USE' Occupancy (per Int'1 Building Code): 128 Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:\Applications\Fonns- Applications On Line3-2006 - Permit Application.doc Revised 9 -2006 Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. /-tri-t Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY TH A AD A a EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJUR TH: OF THE S BUILDING 0 Signature: Print Name: (-6 Mailing Address: O&M ?� "AP rticAp Qh s A e_c Cry 61) z r Date Application Expires: MO 041 Date Application Accepted: 1.2.1 1 SU6M N Zl� /k ~` Ni /rah O S 7e (20 C pit-dr_ile014- MO 2-(` -0 t Lilo C9-4 6 ' r (Ho s Q: Applications\Forms- Applications On Line \3-2006 - Permit Application.doe Revised: 9 -2006 [d. tip GgvcCS Zits in this applca ATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: ` Z oq c1 Day Telephone: ( It b S 't ( 't' City State Staff Initials: Zip Page 6 of 6 RECEIPT NO: R08 -01226 Initials: JEM User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://Www.cidukwila.wa.us Payee: HORIZON RETAIL CONSTRUCTION, INC. SET ID: 0418 SET NAME: GUESS SET TRANSACTIONS: Set Member Amount Doc: RECSETS - 06 D07 -454 2,621.99 EL07 -770 574.00 M07 -271 406.06 PG07 -334 118.00 TOTAL: 3,720.05 SET RECEIPT Payment Date: 04/18/2008 Total Payment: 3,720.05 TRANSACTION LIST: Type Method Description Amount Payment Check 156585 3,720.05 TOTAL: 3,720.05 ACCOUNT ITEM LIST: Description BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 2,619.98 000.322.101 00.0 574.00 000/322.100 406.06 000/322.100 118.00 000/386.904 2.01 TOTAL: 3,720.05 1326 04/18 9711 TOTAL 3720.05 RECEIPT NO: R07 -02719 Initials: JEM User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payee: NATIONAL SERVICES GROUP SET ID: S000000912 SET NAME: Trap set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -454 1,705.48 EL07 -770 143.50 M07 -271 94.02 PG07 -334 24.50 TOTAL: 1,967.50 TRANSACTION LIST: Type Method Description Payment Check 333590 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE SET RECEIPT TOTAL: Payment Date: 12/11/2007 Total Payment: 1,967.50 Amount 1,967.50 1,967.50 Account Code Current Pmts 000.345.832.00.0 143.50 000/345.830 1,821.51 000/386.904 2.49 TOTAL: 1,967.50 5919 12/11 9710 TOTAL 1967.50 Project: ' (."7/S F �. Type of Inspection: , /---/ /L 4 9` I Address: yo 7 ,7 Date Called: Special Instructions: Date Wanted: _2 2-618- p.m. Requester: Phone Z J33 /-D Z.e INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: PERMIT NO. (206)431 -3 COMMENTS: &wm' canFteve to .-, (, N * = VI) ee,o-t1 Q'r. Approved per applicable codes. ❑ Corrections required prior to approval. Date: L f 21 I ` e) El $60.00 RE1NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Type of Inspection: '�1 N ( P ica - l-� Ad ress • x -16-7 rt f- (( (( Pi- ;di- /1- fcrk' -- efrT ;F«. /A. n 7s..' /t H -1 wdee re. 1 --s-- - (�' ?'-Yt nn ,- : 1,z44, l. Y/.'n �, 17 F",,,,17.,',1 r Project c0u f,S Type of Inspection: '�1 N ( P ica - l-� Ad ress • x -16-7 rt f- (( Date Called: Special Instructions: Date Wanted: (a —L q--O Requter: Phone No: 2,Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Z 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36V0 C) Approved per applicable codes. El Corrections required prior to approval. 1Date EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Inspector: 'Receipt No.: Date: Projec 7// j Type of Inspection: / N4 I rYi /7 Address : G7 4141 / Date Called: Special Instructions: Date Wanted: a. Requester: Phone No: 962 -' _ 3. / -GSS - G INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: i t/ CIL Lr r e ( . /'P C�: r /re 401' back - �a� u /elleyiltel /o El $60.0 NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Proje � 1 t (SS' Type Inspectio{! eNc - 1 � r Add� ss: fi_ ( .4 Date Called: Dat 1 a nted: ^ � S 2 (J -iJe---, �m p.m. Special Inst uctions: Requester: Phone No: 1 - INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: Z6/ $58. INSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Projec Type of Inspection: Ad re l( Date Called: - Special Instructions: Date Wanted: S — — dl . 7 p.m. Requester: Phone No e 6-072 -6/( INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDINC15iVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. E1 Corrections required prior to approval. COMMENTS: p / Inspector C J ED $58 INSPECTION FEE REQUIRED. Prior to inspection, fee must be pa 'd 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: &roan( Aio DOI/ G . /O 1,0 e-141 ,4y G �- INSPECTION RECORD. Retain a copy with permit Date: 'Date: j Jennifer Marshall - Guess Southcenter Tukwila WA Change of contact From: "Lauren Chase" <lauren _chase @nationalpermits.com> To: "Jennifer Marshall" <jarshall @ci.tukwila.wa.us> Date: 01/09/2008 1:16 PM Subject: Guess Southcenter Tukwila WA Change of contact CC: "'Lauren Chase.NSG (Lauren Chase.NSG)'" <lauren chase@nationalpermits.com> From: Lauren Chase, National Account Manager National Services Group 626 C Admiral Drive, Pmb Suite 120 Annapolis, MD 21401 Tel 410 544 1700 <mailto:lauren chase@nationalpermits.com> http: / /www.nationalpermits.com Westfield South Center Mall Guess # Guess 633 Southcenter Mall Space 1545 Tukwila WA 98188 D07 -454 EL07 - 770 M07 - 271 PG07 - 334 Brett Delmez Tel 314 - 721 -1340 PM Mobile # Arch : Epoch GC : Pdg Fax 410 544 1692 Lauren : Cell 443 994 8531 Re: Report To: Retail Dev Team : 1) Change of contact request (To : Lauren Chase ) 2) Please forward the latest comments (12 21 07 ) If you have any questions, please contact the writer at Tel 410 544 1700 Page 1 of 2 f \' file: / /C:\ Documents% 20and% 20Settings\ iennifer -m\ Local %20Settines \Temn\XPGrnWis... 01/09/200R Thank You Lauren Chase, National Account Manager National Services Group, Inc Page 2 of 2 NSG INC 2006 All Rights Reserved . This Document and the associated documentation are the property of NSG INC and may be used under license as authorized by NSG INC. Please Note : All reporting data / status / estimates / accuracy are time sensitive and may / wit be revised / updated ,please contact the NSG and or the goveming jurisdiction if you have any questions . Final Approval is directly contingent upon acceptance and approval by the governing jurisdictional authorities of the required Owner / Designer / Contractor documentation.Approval Notification : The Client and /or their General Contractors , Subcontractor(s), Vendor(s) must submit their required License(s) , Insurance(s) , Bond(s) , Fee(s),etc as required to the governing jurisdictions This email and any attachments are confidential and intended solely for the use of the named addressee. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited. E -mail transmission cannot be guaranteed to be secure or error -free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. if verification is required please request a hard -copy version file: //C : \ Documents %20and %20S ettings \j ennifer -m\ Local %20S ettings \Temu\XPGrD Wis... 01/09/2008 December 21, 2007 Randy Kopp 1341 Chestnut Ridge Dr State College PA 16803 Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Plumbing/Gas Piping Application Number PG07 -334 Guess — 467 Southcenter Mall Dear Mr. Kopp, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 - 3670. Sincerely, Bill Rambo Permit Technician encl xc: File No. PG07 -334 P:\Pemut Center■Correction Letters \2007\PG07 -334 Correction Ltr #1.DOC wer Steven M Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: • December 20, 2007 Project Name: GUESS Permit #: PG07 -334 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please make provisions for one drinking fountain. Drinking fountain shall meet the accessibility requirements. (IBC 2903.4.1) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. DEPARTMENTS: Bui g Division Public Works ❑ Complete L Comments: ,.PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG07 -334 DATE: 01 -17 -08 PROJECT NAME: GUESS SITE ADDRESS: 467 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued 2 -oe Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Planning Division ❑ Permit Coordinator C DUE DATE: 01-22 -08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 No further Review Required DATE: DUE DATE: 02-19-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG07 - 334 DATE: 12 - - PROJECT NAME: GUESS SITE ADDRESS: 467 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued D ' ARTMENTS: Bui •(ng 'vision Fire Prevention .11-3 Public Works Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-13-07 Complete ri Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route El Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ❑ Permit Coordinator DATE: DATE: Planning Division n Not Applicable n No further Review Required DUE DATE: 01-10-05 2/ Approved with Conditions ❑ Not App roved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: (kg._ '12/28/2007 06:15 Revision submittals must bk submitted in person at the Permit Center. Revisions will not be accepted through the mall, fax, etc. Date: t -- i - Oe) ❑ Response to Incotnplefe.Letter # ® Response to Correction Letter # 1 ❑ Revision # after Ienmit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Nam: Guess Contact Person: 814690' City. of Tukwila Department of Community Development 0300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:!206 -431.3670 Fax: 206 -431 -3665 Web site: htipJ /www.ci.tukwila.wa.us Ran TKG CONSULTING Plan Check/Permit Number: PG47 -334 Project Address: 467 Southcenter Mall U d@ WI Phone Number: Summary of Re '. on: the ∎<nKvl'1 Fcx ^eiT A Mr\ Vu AS A\ - PAGE 03/03 Steven M Mullet, Mayor Steve Lancaster, Dir etnr U4 Y BF JAN 1 7 2008 PERMIT CENTER l ,et l Lac Rcx , t-1 CoL R1/4 S�IA �i ?re. fi esS_1 - lke tt, e. le - s tp vice -- • Sheet Number(s): 1.t � YA� �� laotz - eCCeteAk VOctLDe t.4. 0 - "Cloud" ur highlight ail areas of revision including date of revis Pit 1 • Received at the City of Tukwila Permit Center by: lg Entered in Permits Plus on 611 11 at \applications\forms- applications on Iinelrevision submittal Created: 8 - 13 - 2004 Revised: S Ve°c E' kica'iS License Information License HORIZRC072N5 Licensee Name HORIZON RETAIL CONST INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601483044 Ind. Ins. Account Id Business Type CORPORATION Address 1 1458 HORIZON BLVD Address 2 City RACINE County OUT OF STATE State WI Zip 53406 Phone 2626386000 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/25/1993 Expiration Date 4/15/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HENDERSEN, JON E 01/01/1980 GUSTIN, ROBERT L 01/01/1980 HENDERSON, JON E 01/01/1980 JAWORT, DAN AGENT 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= HORIZRC072N5 04/18/2008 PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louis, MO 63132 T0.: 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: TIPS DOCUMENT L5 THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED As RATED, ALL RIGHTS RESERVED. A JrHORTLATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT IS NOT TRANSFERABLE. THE RECIPIENT OF TEES D001MENT HERESY ADVISED THAT IT I5 REJ. A e D FOR USE LENDER THE FOLLOWING TERMS AND CONDi 1ON5, THE DOCUMENT 15 TO BE U ONLY IN CONJUNCTION WITH THIS PROJECT. REUSE OF ANY PORTION OF THE DOO MENT ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT 15 FOR DESIGN LATENT APO INFORMATION ONLY, AND DOES NOT CONSTITUTE AS-BUILT COMMONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERFy THE CONDITIONS OF THE SUBJECT PROPERTY AIWA TO COMPLETELY COORDINATE ALL OMENS ONE FABRICATION METHODS, RELATED AND IM EGRATED SYSTEMS, FTC, WITH RESPECT TO ALL ASPECTS OF THE WORK EPOCH DESIGN GROUP MAKES NO WARRANTY AS TO THE SIIRABIUTy OF THE DOCUMENT FOR THE RECPENYS INTENDED USE. THE REORIENT SPE0RCALLY AGREES TO WAIVE AND TO INOEMNFY AND DEFEND ANY AND ALL CLAIMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, AN Y OF ITS RELATED ENTRIES VENDORS, OR CONTRACTORS, FOR ANY L055 INCURRED AS A RESULT OF PROPER OR IMPROPER USE OF 1I11S DOCUMENT. TFIE RECIPIENT AGREES TO RETURN OR DESTROY 045 DOCUMENT UPON COMPLETION OR TERMINATION OF WORE PERFORMED IN ccNJUNCTION wRFJ THE PROEECT. PROFE55IO vat PROJECT TITLE SHEET TITLE: COVER SHEET RANDALL A. NELSON 8016 Reeder Rd, Lenexa, K5 66214 TEL 913- 322 -5150 FAX: 913- 322 -5155 JAN 17? 3 rc, pai T CcN uJ V) CO RECEIVED CITY OF T UKVVILA 2 LL. /OWNER /CITY CMNTS 01 /10 /08 1 L.L. / OWNER COMMENTS 12/14/07 No.A Revision Description Date PROJECT NO.; SHEET NUMBER; 07073 DRAWN BY: 1 • 0 KS ISSUE DATE; 11/13/07 s F ODE. i i /1 +` . i � k ............ :� �ad`0 ;i ' cO APL1 ,mo ��:�9 ? I. r __ FILE Putt � , 4 1 .. yip v COPY No. 3 4 �eIs �to alnd�■ Approval of �► does not abhor ze lte vbtaUon of any iced Code or oid Ica Receipt of approved Copy and cons Is acknowledged: BY b d . # 5089 ..)EPARATE PERMIT REQUIRED FOR: Mechanical at Electrical 0 Plumbing ❑ Gas Piping City :1 Tukvviia GUII 1 11 ,,,, D liSION City of Tukwila BUILDING DIVISION } r�•i'7L 1 7 No { �� A � Y e ui rr�T rl��C� k y�� : . a :::aid'r:- ` .�• '� I:�,1� 1� •'; , 'u i/' 1LiC+ 0 U C ' ��� tl�".: 101. f�$5. ry Y�!� C,Jtilivrul }']L Jet' "�s�1 .rte A.F.F. ABOVE FINISHED FLOOR IN.( ") INCH A.P. ACCESS PANEL INT. INTERIOR AC, ACOUSTICAL JT. JOINT AC.T. ACOUSTICAL TILE MFR. MECH. MANUFACTURE (R) ADJ. ADJACENT MECHANIC (AL) ALT. ALTERNATE MTL METAL A.B. ANCHOR BOLT MEZZ. MEZZANINE APPROX. APPROXIMATE MIN. (') MINIMUM, MINUTE APVD, APPROVED MISC. MISCELLANEOUS ARCH. ARCHITECT (URIC) N.I.C. NOT IN CONTRACT BLK. BLKG. BLOCK N.T.S. NOT TO SCALE BLOCKING NO. or # NUMBER BD. BOARD D.F.C.I. OWNER FURNISHED CONTRACTOR BTTM. BOTTOM INSTALLED CSWK. CASEWORK O.F.O.I. OWNER FURNISHED OWNER INSTALLED CEM. CEMENT O.C. ON CENTER (5) CLG. CEILING OPNG. OPENING CLG.HT. CEILING HEIGHT OPP, OPPOSITE CHNL CHANNEL PART. PARTICLE CLR. CLEAR (ANCE) P. LAM. PLASTIC LAMINATE CLO. CLOSET PLBG. PLUMBING COL COLUMN PWD. PLYWOOD C.M.U. CONCRETE MASONRY UNIT PVC. POLYVINYL CHLORIDE CONST. CONSTRUCTION PREFAB. PREFABRICATED C.J. CONSTRUCTION JOINT P.M. PROJECT MANAGER COORD. COORDINATE QTR. QUARTER CORR. CORRIDOR R.A. RETURN AIR CTR. CENTER R.C.P. REFLECTED CEILING PLAN C.T. CERAMIC TILE REF. REFERENCE DET. DETAIL REG. REGISTER DIAG. DIAGONAL REINF. REINFORCE (D), (ING) DIA. DIAMETER REQ'D. (REQ.) REQUIRED DIF. DIFFUSER REV. REVISION (5), REVISED DIM. DIMENSION R.O. ROUGH OPENING 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LANDLORD'S CRITERIA AND ALL 16. ALL EXISTING AND NEW FIRE RATED CONSTRUCTION AT COLUMNS, CEILING, END LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. WALLS, ETC., INCLUDING FIRE DAMPERS, SHALL COMPLY WITH LANDLORD AND LOCAL CODE REQUIREMENTS. 2. THE GENERAL CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, APPROVALS, LICENSES AND CERTIFICATES TO COMPLETE THE PROJECT. 17. ALL INTERIOR AND STOREFRONT FINISHES MUST MEET LOCAL CODE AND LANDLORD FLAME SPREAD REQUIREMENTS. MINIMUM TO BE CLASS C (III) OR BETTER. 3. THE GENERAL CONTRACTOR SHALL CARRY WORKMAN'S COMPENSATION, LIABILITY, AND PROPERTY DAMAGE INSURANCE & PAY FOR SAME. REFER TO 18. ANY WOOD FRAMING AND BLOCKING SHALL BE FIRE RETARDANT TREATED AS "CONSTRUCTION CONTRACT" FOR REQUIRED AMOUNTS ETC. REQUIRED BY LOCAL CODES. ( 4. THE GENERAL CONTRACTOR SHALL VERIFY WITH OWNER WHETHER STORE I5 TO 19. ALL PARTITIONS, CEILINGS, LIGHT FIXTURES, DUCT WORK, ETC. TO BE BRACED TO REMAIN OPEN DURING CONSTRUCTION WHERE APPLICABLE . STRUCTURE TO RESIST SEISMIC LOADING AS REQUIRED BY LOCAL CODES. ) 5. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND 20. ALL STOREFRONT CONSTRUCTION IS TO BE SELF - SUPPORTING FROM THE FLOOR DIMENSIONS AND REMOVE ALL EXISTING ELEMENTS AND FIXTURES NOT RELEVANT TO AND ATTACHED TO LANDLORD STRUCTURE ABOVE FOR LATERAL BRACING ONLY NEW WORK. (UNLESS SPECIFICALLY INDICATED OTHERWISE). 6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS. 21. THE GENERAL CONTRACTOR SH CONSTRUCT A METAL STUD & GYP. BD. VERIFICATION OF ALL DIMENSIONS SHALL BE PERFORMED. REPORT ANY CRITERIA UNLESS OTHERWISE DIRECTED BY LANDLORD. G.C. TO VERIFY REQUIREMENTS DISCREPANCIES AND/OR CONFLICTS TO THE ARCHITECT AND OWNER'S WITH LANDLORD REPRESENTATIVE PRIOR TO START OF CONSTRUCTION. / REPRESENTATIVE PRIOR TO PROCEEDING WITH THE WORK. CONTRACTOR TO INSTALL OWNER SUPPLIED GUESS? BARRICADE GRAPHIC (WHERE PROJECT ARCHITECT L ANDLORD /TENANT COORD. EPOCH DESIGN GROUP, INC. WESTFIELD GROUP 1 155 OLIVETTE EXECUTIVE PARKWAY V11-40-1 JW1 HIRE BLVD SUITE 100 14TH FLOOR ST. LOUIS, MO. 63132 tOS'Ar G ES, CA 90025 314 -721 -1340 310 -893 -4761 CONTACT: BRETT DELMEZ CONTACT: JOSHUA KIMMEL A PROJECT ENGINEER PROJECT ADDRESS [ PDRE RETAL N �� ❑ J ` macys i NORDSTROM -o-1 0 0 0 0 0 0 ❑ ° ° O 0 ° 0 `_. - Il ❑° - RANDALL A. NELSON, P.E. $016 REEDER RD GUESS? 467 SOUTHCENTER MALL LENEXA, K5.66214 SUITE 1545 913.322 -5150 SEATTLE WA 98188 CONTACT: RANDY NELSON 206- 246 -0423 CONTACT: HEATHER ALMOND CONSTRUCTION MANAGEMENT 0 0 _r , ❑ _.;�� i - • -i ❑ _ A L-7:1 j. . . o o _ 0• 4 a k• dI GUESS?, INC. 1444 SOUTH ALA STREET L 90021 • G CA 90021 , y I GUESS SPACE NO. 1545 PERMITTED) 48 HOURS AFTER START DATE, BARRICADE CONSTRUCTION OR RECEIPT OF 7, THE GENERAL CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING GRAPHICS. BARRICADE TO BE PAINTED W/ / LATEX SEMI -GLOSS PAINT (PTT) PRIOR TO UTILITIES, AIR DUCTS, MECHANICAL EQUIPMENT, ETC., AND LOCATIONS OF PROPOSED GRAPHIC INSTALL. G.C. WILL OBTAIN AND INSTALL MALL GRAPHIC WHERE REQUIRED. CONNECTIONS TO SAME. ANY DISCREPANCIES OR CONFLICTS SHOULD BE REPORTED TO ARCHITECT & OWNER'S REPRESENTATIVE IMMEDIATELY. 22. LIGHT FIXTURES AND LAMPS ARE OWNER FURNISHED, CONTRACTOR INSTALLED. 8. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL 23. ALL PLASTIC LAMINATE AND METAL FIXTURE EDGES MUST BE DE- BURRED PRIOR TO WORK PERFORMED BY HIS LABORERS, SUBCONTRACTORS OWNER'S CONTRACTORS TURNOVER TO ELIMINATE ANY SHARP EXPOSED EDGES WHICH MAY COME INTO AND OTHERS. CONTACT WITH STORE OCCUPANTS. _ 1 r `- - - ". -'` -''' '' -N -- - -� -s'-'-v- '/- ' -' ' - - 9A. THE SIGN MANUFACTURER SHALL BE RESPONSIBLE FOR SUBMITTING FOR AND 24. G.C. SHALL PROVIDE ARCHITECT WITH DIGITAL PROGRESS PHOTOS AT EACH OBTAINING LANDLORD APPROVAL PRIOR TO COMMENCING WITH FABRICATION, INSPECTION POINT DURING CONSTRUCTION. PHOTOS SHALL BE FORWARDED BEFORE EACH REQUIRED INSPECTION AND INCLUDE FRAMING DETAILS, STOREFRONT 814-861-3818 _ * ' • DY KOPP OWNER 41111b GUESS? INC. 1444 SOUTH ALAMEDA STREET LOS ANGELES, CA 90021 ' gir PROJECT CONTACTS MALL KEY P LAN LEVEL 1 OF 3 , (INTERIOR LOCATION) DISP. DISPENSER RND. ROUND DR. DOOR SHT. SHEET DWR. DRAWER SIM. SIMILAR DWG. DRAWING S.C. SOLID CORE ELEC. ELECTRICAL S.S. STAINLESS STEEL E.P. ELECTRIC PANEL STD. STANDARD ELEV. ELEVATION STL STEEL E.W.C. ELECTRIC WATER COOLER 5T0. STORAGE EXIST EXISTING S.D. STORM DRAIN EQUIP. EQUIPMENT STRUCT. STRUCTURAL EXH. EXHAUST SUSP. SUSPENDED EXP. JT, EXPANSION JOINT SYM. SYMMETRY (ICAL) FIN. FINISH (ED) SYS. SYSTEM F.E. FIRE EXTINGUISHER T.B.D. TO BE DETERMINED FP. FIREPROOFING TEL TELEPHONE F.D. FLOOR DRAIN TS. TUBE STEEL FLUOR. FLUORESCENT TYP. TYPICAL F.R.T. FIRE RETARDANT TREATED U.N.O. UNLESS NOTED OTHERWISE FURR. FURRED (ING) VERT, VERTICAL GA. GAUGE VEST. VESTIBULE GALV. GALVANIZED V.C.T. VINYL COMPOSITION TILE G.C. GENERAL CONTRACTOR V.I.F. VERIFY IN FIELD GYP. BD. GYPSUM BOARD W.C. WATER CLOSET H.V.A.C. HEATING /VENTILATION/ WP. WATERPROOF(ING) AIR CONDITIONING WS. WEATHER STRIPPING H.C. HOLLOW CORE W/ WITH H.M. HOLLOW METAL W/O WITHOUT HORIZ. HORIZONTAL WD. WOOD H.W. HOT WATER W.P. WORKING POINT 9B. REFER TO INSTRUCTIONS TO BID FOR SIGN PERMIT RESPONSIBILITY. FRAMING AND SUPPORT, HVAC EQUIPMENT SUPPORT, TOILET ROOM DETAILS, STOCK SHELVING SPRINKLER CLEARANCES, AND FINAL FINISHED STOREFRONT PHOTO. ANY / 10. THE GENERAL CONTRACTOR SHALL THOROUGHLY CLEAN THE SPACE, MAKING IT UNUSUAL CONDITIONS SHOULD ALSO BE DOCUMENTED AND FORWARDED TO READY FOR MERCHANDISE, WHICH SHOULD GENERALLY CONSIST OF VACUUMING, ARCHITECT. DUSTING, WASHING WINDOWS AND CLEANING ALL FLOORS. r i���/�_/����ti/�_��__/L / •_�A -_ - �/ti__/��` / _��_ 1 1. IT IS REQUIRED THAT EACH BIDDER VISIT THE SITE AND FULLY ACQUAINT THEMSELVES WITH THE EXISTING CONDITIONS AND THE SCOPE OF THE PROJECT PRIOR TO SUBMITTING THEIR BIDS. FAILURE TO DO SO SHALL NOT RELIEVE THE CONTRACTOR FROM LIABILITY DUE TO OMISSIONS FROM BID. CHANGE ORDERS DUE TO SAID OMISSIONS WILL NOT BE ACCEPTED. 12. THE GENERAL CONTRACTOR SHALL ARRANGE FOR AN ORIENTATION MEETING WITH THE LANDLORD'S REPRESENTATIVE PRIOR TO START OF CONSTRUCTION. 13. THE GENERAL CONTRACTOR SHALL PROTECT FROM DAMAGE ALL EXISTING SURFACES, MATERIALS, FIXTURES, ETC. TO REMAIN DURING THE COURSE OF THE PROJECT. THE G.C. SHALL BE RESPONSIBLE FOR REPAIRING ANY AND ALL DAMAGE BY HIMSELF OR HIS SUBCONTRACTORS DURING THE COURSE OF THE PROJECT. REPAIRS ARE TO MATCH EXISTING MATERIALS AND MUST BE ACCEPTABLE TO LANDLORD OR OTHER GOVERNING AGENCY. 14. ALL FLOOR TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE SMOOTH AND FLUSH. (MAXIMUM SLOPE = 1/8" PER FOOT.) 15. FIRE BLOCK ALL WALLS AND FIRE STOP ALL PENETRATIONS AS REQUIRED BY LOCAL BUILDING CODES. SHEET NO.: DESCRIPTION BUILDING CODES: 2006 INTERNATIONAL BUILDING CODE WITH � i WASHINGTON STATE AMENDMENTS 2006 INTERNATIONAL MECHANICAL CODE WITH < WASHINGTON STATE AMENDMENTS 2006 UNIFORM PLUMBING CODE WITH < 7 WASHINGTON STATE AMENDMENTS 2006 NATIONAL ELECTRICAL CODE WITH � WASHINGTON STATE AMENDMENTS < ( 2006 WASHINGTON NON RESIDENTIAL ENERGY CODE > < ( 2006 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS CORRECTION 1 0- - C1.0 COVER SHEET C2.0 SPECIFICATIONS D1.0 PARTIAL EXISTING CONDITIONS PLAN D1.1 PARTIAL EXISTING CONDITIONS PLAN Al 0 PARTIAL FLOOR PLAN A1.1 PARTIAL FLOOR AND REFLECTED CEILING PLAN A1.2 FINISH PLAN A2.0 PARTIAL REFLECTED CEILING PLAN A2.1 SCHEDULES A3.0 INTERIOR ELEVATIONS A3.1 INTERIOR ELEVATIONS A3.2 STOREFRONT ELEVATIONS A4.0 ENLARGED STOREFRONT PLAN A4.1 STOREFRONT SECTIONS A4.2 STOREFRONT SECTIONS A5.0 DETAILS A5.1 DETAILS F1,0 FIXTURE PLAN AND DETAILS F1.1 FIXTURE ELEVATIONS DETAILS AND SCHEDULES M1.0 MECHANICAL FLOOR PLAN M2.0 HVAC SPECIFICATIONS AND DETAILS M3.0 MALL NOTES E1.0 ELECTRICAL CEILING PLAN E2.0 ELECTRICAL POWER PLAN E3.0 ELECTRICAL DETAILS E4.0 ELECTRICAL SPECIFICATIONS, PANELS, AND RISER - P(10 USE GROUP CLASSIFICATION: - ■,-- ,(a1 CONSTRUCTION TYPE /CLASSIFICATION: TYPE II -B TENANT SEPARATION REQUIRED: 1 -HOUR RATED ASSEAv B FIRE SUPPRESSION SYSTEM: FULLY SPRINKLERED AREA CALCULATIONS: OCCUPANT LOAD: SALES FLOOR AREA 3,747 S.F. 125 STOCK ROOM AREA 764 S.F. 3 UNASSIGNED (BATHROOM /CORRIDOR): 80 S.F. 0 TOTAL: 4,591 S.F. 128 ABBREVIATIONS MISCELLANEOUS PROJECT NOTES INDEX OF DRAWINGS BUILDING CODE DATA PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louis, MO 63132 T0.: 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: TIPS DOCUMENT L5 THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED As RATED, ALL RIGHTS RESERVED. A JrHORTLATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT IS NOT TRANSFERABLE. THE RECIPIENT OF TEES D001MENT HERESY ADVISED THAT IT I5 REJ. A e D FOR USE LENDER THE FOLLOWING TERMS AND CONDi 1ON5, THE DOCUMENT 15 TO BE U ONLY IN CONJUNCTION WITH THIS PROJECT. REUSE OF ANY PORTION OF THE DOO MENT ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT 15 FOR DESIGN LATENT APO INFORMATION ONLY, AND DOES NOT CONSTITUTE AS-BUILT COMMONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERFy THE CONDITIONS OF THE SUBJECT PROPERTY AIWA TO COMPLETELY COORDINATE ALL OMENS ONE FABRICATION METHODS, RELATED AND IM EGRATED SYSTEMS, FTC, WITH RESPECT TO ALL ASPECTS OF THE WORK EPOCH DESIGN GROUP MAKES NO WARRANTY AS TO THE SIIRABIUTy OF THE DOCUMENT FOR THE RECPENYS INTENDED USE. THE REORIENT SPE0RCALLY AGREES TO WAIVE AND TO INOEMNFY AND DEFEND ANY AND ALL CLAIMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, AN Y OF ITS RELATED ENTRIES VENDORS, OR CONTRACTORS, FOR ANY L055 INCURRED AS A RESULT OF PROPER OR IMPROPER USE OF 1I11S DOCUMENT. TFIE RECIPIENT AGREES TO RETURN OR DESTROY 045 DOCUMENT UPON COMPLETION OR TERMINATION OF WORE PERFORMED IN ccNJUNCTION wRFJ THE PROEECT. PROFE55IO vat PROJECT TITLE SHEET TITLE: COVER SHEET RANDALL A. NELSON 8016 Reeder Rd, Lenexa, K5 66214 TEL 913- 322 -5150 FAX: 913- 322 -5155 JAN 17? 3 rc, pai T CcN uJ V) CO RECEIVED CITY OF T UKVVILA 2 LL. /OWNER /CITY CMNTS 01 /10 /08 1 L.L. / OWNER COMMENTS 12/14/07 No.A Revision Description Date PROJECT NO.; SHEET NUMBER; 07073 DRAWN BY: 1 • 0 KS ISSUE DATE; 11/13/07 1. SEE ELECTRICAL DRAWINGS FOR ALL LUMINAIRE SPECIFICATIONS. /1 A ` L ' 2. PROVIDE ACCESS PANELS IN HARD SURFACE CEILINGS AS NECESSARY FOR ACCESS TO TENANT AND LANDLORD CONTROLS, VALVES, EQPT., ETC. ALL PANELS SHALL BE OF SAME TYPE AND SIZE, TAPED -IN FLUSH AND PAINTED TO MATCH CEILING. COORDINATE NUMBER AND LOCATION OF ACCESS POINTS W/ SITE CONDITIONS AND THESE DOCUMENTS. PANELS TO BE: INTEX ACCESS PANELS. AVAILABLE FROM GLENDON COMPANY, 23677 FOLEY ST., HAYWARD, CA 94545 TEL 510- 887 -8000 OR 510- 887 -8025 CONTACT: JENNIFER OR PAUL COORDINATE REQUIRED LOCATIONS WITH THE LANDLORD REPRESENTATIVE. 3. SPRINKLER HEADS AND OTHER MISCELLANEOUS CEILING DEVICES SHALL BE INSTALLED CENTERED WITHIN FULL OR PARTIAL ACOUSTICAL TILES, AND ALIGNED WITH OTHER DEVICES AND /OR LUMINAIRES WITHIN GYPSUM BOARD CEILINGS SHOWN ON THIS PLAN. SPRINKLER HEADS IN CEILINGS VISIBLE TO THE PUBLIC SHALL BE CONCEALED TYPE WITH COVERPLATES. SEE MEP DRAWINGS FOR SPRINKLER HEAD AND OTHER MISCELLANEOUS CEILING DEVICE LOCATIONS. 4. SUPPORT WIRES FOR SUSPENDED CEILING SYSTEMS SHALL BE ATTACHED TO THE BUILDING STRUCTURAL SYSTEM, AND SHALL NOT BE CONNECTED TO ELEMENTS OF ANY MECHANICAL, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS. 5. ALL CEILING FINISHES SHALL HAVE CLASS 'A' AND /OR CLASS 'I' RATING, DEPENDENT UPON CLASSIFICATION NOMENCLATURE OF THE LOCAL CODE IN EFFECT. 1. ARCH TO VERIFY WITH FIRE DEPT ON STOCK ROOM SHELVING HEIGHT AND CLEARANCE '/ FROM TOP OF SHELVING TO SPRINKLER DEFLECTOR SHIELD. (\ 2. PERMIT 15 REQUIRED FOR ALL STORAGE RACKS MORE THAN 5' -9" IN HEIGHT. SEE ( SOUTHCENTER PLAN SUBMITTAL CHECKLIST. NO RACK STORAGE IS ALLOWED 12' -0" OR ' HIGHER. VERIFY WITH FIRE MARSHALL WHETHER SIDE SLIDING STOCK ROOM SHELVING (' WILL BE ALLOWED SINCE FIRE PROTECTION LANDLORD'S SPRINKLER SYSTEM IS DESIGNED FOR ORDINARY HAZARD GROUP 2. 3. OPEN TO STRUCTURE TYPE DESIGNS ARE NOT ALLOWED DUE TO THE USE OF COMMON ( PLENUM RETURNS WITHIN THE MALL HVAC SYSTEM. ( 4. LAY IN ACOUSTICAL TILES MAY NOT BE USED IN FORWARD SELLING AREA. TILES TO O HAVE NOISE REDUCTION COEFFICIENT OF 0.60 -0.70 WITH A MINIMUM ROOM ATTENUATION FACTOR OF 40.0 DECIBELS AND MUST MEET ALL CODE, FLAME SPREAD, FUEL ( AND SMOKE DEVELOPMENT FACTORS. ( ( 1. THE G.C. SHALL INSTALL SLAB SEALER PRIOR TO FINISHED FLOORING INSTALLATION. REFER TO THE FINISH SCHEDULE FOR MORE INFORMATION. 2. THE TENANT'S STOREFRONT IS TO BE FLOOR - SUPPORTED AND SHALL ATTACH TO THE LANDLORD'S STRUCTURE FOR LATERAL SUPPORT ONLY. 3. THE G.C. SHALL REVIEW ALL ELEVATIONS, FIXTURE PLANS AND DETAILS FOR LOCATIONS OF METAL STRAP BACKING IN WALLS AND MOUNTING REQUIREMENTS FOR FIXTURE, EQUIPMENT AND GRAPHIC /SIGN INSTALLATIONS PRIOR TO BEGINNING CONSTRUCTION. THE G.C. SHALL COORDINATE INSTALLATION OF ALL SUCH BACKING. 4. THE G.C. SHALL INSTALL MOISTURE RESISTANT GYPSUM BOARD TO 4' -0" A.F.F. MINIMUM IN ALL BATHROOMS, AROUND MOP SINKS, LIMITED EXTERIOR EXPOSURES, AND OTHER LOCATIONS SUSCEPTIBLE TO MOISTURE U.N.O. 5. THE G.C. SHALL INSTALL SEALANT AT THE TOP AND BOTTOM OF WALL BASE TRIM INSTALLED AT THE SALES FLOOR. THE SEALANT COLOR SHALL CLOSELY MATCH THE WALL BASE TRIM. ALLS U.N.O. 5 CEILING CONSTRUCTION NOTES 4 - _-' . -- LANDLORD COMMENTS � 3 - 2 �- 1 GENERAL CONSTRUCTION NOTES SCALE: SCALE: .._ .._. J \�'_ /_J.._,`��� � 0 < C,.... J.8 O pZ O Va 0 I - .... . .... ... / W 1 26., OTIMal 3 u„, ,, ,., , .--„,, ,, r,,, =:. .,. 6: : ,... 5 J , - s.o TYP. 38' -0" 11 - L/ /1/ / 1 _ . .... / r / / . .. _ ' • ./ . ,/ r / / . ' / 1 r, ii /Mr/ r Will // /wiww / /rilir! -j" ,f, P. 7:,. �ili // B ill /' AMA" i!i!r/ iiii 4/....W wwii r / /rwiwi� r MAKI +1 -' � , % I g ` 1 �rrrw 'b3 - _ CLEAR FROM DECKABOVE FIRE TAPE O. 6 " C � AND SEAL TO MAINTAIN 1 HR. RATING ! I Ca rQ ELEC. EQUIP SEE ELEC. DWGS. STOCK ROOM I I 1 1F LLUJ - 3 L..ui / f 6 1 __ Alik CG1 .f �, A 5.0 / , Mil MI VP _� Ark EQ. ' o 5.0 . --"-___,---,_./ I .o � . 0 / / A 1 1 8 =Q . �— W • / / 5 D B 'O3 /I� i . _..__ ._.. - _..__._. _._.._ . T . . . _ ._ .... .- . . ..- N`� ■ `1 min .„... ////////////////f.%///////////////// / / // / / / / / / / / / / / / / / / / / / / / / / / / %%• .,",, // / / / / / / / / / // / // /f / / / / / // 7' -6" At 30' -1" 1 1 . G ° 1 ti z / ROOM AT 8' -0" A.F.F. - PAINT (PT1) SEE DETAIL 1 /A5.1 CEILING AT A.F.F. ACCESSIBLE DRINKING FOUNTAIN MOUNTED 36" A.F.F. TO SPOUT 1 O / 2 X 4 ACT. 14' -0" O oZ O LL z Z Tn F -- Q w Q �n C 2 TOILET ROOM • 5.0 -� G.C. TO INSTALL 1 LAYER %" TYPE 'X' GYP. BD. TO DECK - FIRE TAPE AND ) SEAL TO MAINTAIN 1 HR. RATING ` 8 O az ¢ H w Z X J r: H Z v8I N PARTIAL REFLECTED CEILING PLAN /,,---„,--,,,,,, PARTIAL FLOOR PLAN SCALE: 1/4" = 1' -0" SCALE: 1 /4" = 1 -0" PROJECT TEAM: Architect: Epoch Design Group, Inc 1 155 Olivette Exec. Pkwy. Suite 100 St. Louis, MO 63132 TEL: 314.721.1340 FAX: 314321.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: TFBS DOCUMENT IS THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGICED AS DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOGI DESIGN GROUP FOR USE OF THIS DOCUMENT LS NOT TRANSFERABLE THE RECIPIENT OF TF1S DOOJMENr I5 HEREBY ADVISED THAT TT L5 RELEASED FOR USE UNDER THE FOLLOWING TERMS AND COMMONS, TFE DOCUMBNT IS TO BE USED ONLY IN CONn2NCTK]N WITH THS PROJECT. REUSE OF ANY PORTION OF THE DOCUMENT H ANY OTHER C ROJMSTANCE CONSTITUTES COPYRIGHT IFFRINGEMENr. THE DOCUMENT 15 FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES NOT CONSTITUTE A5 -BUILT COFO TION5. TFIE RECIPIENT RETAINS THE OBLIGATION TO VEREY THE CONDITIONS OF THE SUBJECT PROPERTY AND TO COMPLETELY COORDINATE ALL DLMENSIONS, FABRICATION METHOD, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF DE WORK EPOCH DESIGN GROUP MAKES NO WARRANTY AS TO THE SUITABILITY OF THE DOOJMENT FOR THE RECIPIENT'S INTENDED USE. THE RECIPIENT SPECIFICALLY AGREES TO WAIVE AND 10 IFOEMNIFY AND DEFEND ANY AND ALL CALMS AGAINST EPOGI DESIGN GROUP, TTS CONSULTANTS, ANY OF [TS RELATED ENTITIES, VENDORS, OR CONTRACTORS, FOR ANY LO55 INCURRED AS A RESULT OF PROPER OR IMPROPER USE OF THIS DOCUMENT. THE RECIPIENT AGREES TO RETURN OR DESTROY THIS DOCIWkNT UPON COMPLETION OR TERMINATION OF WORK PEFORMED N CONJUNCTION WITH THIS PROJECT. PROFESSIONAL SEAL PROJECT TITLE: 2 L.L./OWNER/CITY CMNTS 01/10/08 1 L.L. / OWNER COMMENTS 12/14/07 No.O Revision Description Date SHEET TITLE: PROJECT NO.: 07073 DRAWN BY: A KS ISSUE DATE: 11/13/07 nECEP`JED RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL 913- 322 -5150 FAX: 913- 322.5155 CITY OF TUKWILA IAII 9 nnr, L.� +Ei�lvii i CENTER Lo LLI O w w v7 U a V) PARTIAL FLOOR AND REFLECTED CEILING PLANS SHEET NUMBER: .1 GUESS? NO. 5089 SOUTHCENTER 1, DO NOT ATTACHED ANYTHING DIRECTLY TO SLABE OR ROOF DECK ABOVE. 2. TENANT SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIR FLOW BACK TO AIR CONDITIONING UNIT. 3. TENANTS CONTRACTOR SHALL VERIFY POINTS OF CONNECTION FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT IS RESPONSIBLE FOR EXTENDING PIPING FROM POINT OF CONNECTIONS TO TENANT SAPCE AT TENANTS EXPENSE. 4. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO THE LANDLORDS SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPOVED MECHANICAL FITTINGS (NO ISOLATION VAVLES WILL BE PROVIDED OR PERMITED). TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE SPINKLER SYSTEM WITHIN TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASE UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEPT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANTS FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. 5. TENANTS CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FUNNEL DRAIN (WITH WET TRAP), MOUNTED AT 3'-- 0 "AFF. INSTALL A 1" CORROSION RESISTANT SHUT —OFF VALVE. 6. TENANT SHALL INSTALL A VANE TYPE WATERFLOW DETECTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION THE LANDLORD'S MAIN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. 7. LANDLORD PROVIDED CAPPED SANITARY VENT CONNECTION LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE IN CEILING, VERIFY EXACT LOCATION IN FIELD. TENANT IS RESPONSIBLE TO EXTENCE FROM THEIR SPACE TO POINT OF CONNECTION AT TENANT'S EXPENSE. 5 LANDLORD DESIGN NOTES SCALE: 1 /4" = 1' -0" 1 20 SCALE: 1 /4" = -0" • ,. ALL OF THE MECHANICAL WORK 15 NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THEIR WORK BEFORE BIDDING. NOTIFY THE OWNER OF ANY DISCREPANCIES. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER'S REPRESENTATIVE SHALL BE PART OF THIS CONTRACT. THE SUBMISSION OF PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS CLAIMS FOR EXTRA WORK MADE NECESSARY BY THEIR FAILURE TO VISIT THE SITE. GUARANTEE ALL EQUIPMENT AND MATERIAL INSTALLED UNDER THIS CONTRACT TO BE FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE AND REPAIR OR REPLACE WITHOUT COST TO THE OWNER ANY EQUIPMENT WHICH IS DEFECTIVE, OR IMPROPERLY INSTALLED. IN ADDITION, ASSUME FULL RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING AND ITS CONTENTS OR OTHER EQUIPMENT CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF EQUIPMENT OR MATERIALS INSTALLED UNDER THIS PORTION OF THE WORK. ALL WORK SHALL BE COMPLETED AND INSTALLED ACCORDING TO STATE AND OR LOCAL CODES, AND ALL LANDLORD CRITERIA. PAY FOR ALL REQUIRED PERMITS AND INSPECTIONS AND PROVIDE A CERTIFICATE OF INSPECTION. REVIEW ALL LANDLORD REQUIREMENTS AND INSTALL ALL MATERIALS AND EQUIPMENT AS DIRECTED BY THE LANDLORD'S REPRESENTATIVE AND AS REQUIRED BY THE LEASE DOCUMENTS. VERIFY THE REQUIREMENTS BEFORE SUBMITTING A BID. VERIFY THE SIZE, LOCATION AND CONDITION OF THE EXISTING DUCTWORK, EQUIPMENT AND CONTROLS THAT ARE TO REMAIN. NOTIFY THE OWNER OF ANY DISCREPANCIES. REPLACE EXISTING COMPONENTS IF INADEQUATE FOR THE NEW REQUIREMENTS OR INOPERABLE. COORDINATE REPLACEMENT COMPONENT SPECIFICATIONS WITH THE LANDLORD'S FIELD REPRESENTATIVE. FIVE (5) COPIES OF ALL SHOP OR EQUIPMENT DRAWINGS SHALL BE SUBMITTED TO THE OWNER. THESE DRAWINGS SHALL BE CLEARLY MARKED INDICATING WHICH ITEMS ARE TO BE SUPPLIED AND SHALL STATE CAPACITIES, SIZES, REQUIRED INSPECTION LABELS AND GENERAL DESCRIPTION OF ALL EQUIPMENT AND FIXTURES. ALL AIR INTAKES AND EXHAUSTS NEED TO BE SEPARATED BY A MINIMUM OF 10' -0 ". 10. NO COMPONENTS MAY BE ABANDONED IN PLACE WITHOUT PERMISSION FROM THE OWNER. ALL COMPONENTS THAT ARE NOT REUSED MUST BE REMOVED. 11. VERIFY ALL CLEARANCES AROUND NEW AND EXISTING EQUIPMENT. GENERAL NOTES SCALE: 1 /4" = 1 19 20x20 20x14 20x14 - VAV-2 NOTE: EXISTING CONDITIONS WERE TAKEN FROM SITE VISITS AND MAY NOT REFLECT EXACT "AS- BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. MECANICAL, FIR SPRINKLER AND PLUMBING PLAN SCALE 1 /4" = 1' -0" L $ 0 x 0 N A. FABRICATE AND INSTALL GALVANIZED SHEET METAL DUCTWORK FOR VELOCITIES LESS THAN 2000 FEET PER MINUTE AND STATIC PRESSURES OF LESS THAN 2" WATER GAUGE IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA'S LOW VELOCITY DUCT CONSTRUCTION MANUAL. ALL ELBOWS AND BRANCHES FROM THE MAIN IN ALL SUPPLY AND RETURN DUCTS SHALL BE PROVIDED WITH TURNING VANES. DUCTWORK SHALL BE CONSTRUCTED, INSTALLED, SEALED AND INSULATED IN ACCORDANCE WITH THE LATEST EDITION OF THE MECHANICAL CODE. FIBERGLASS DUCTBOARD I5 NOT ACCEPTABLE. ALL RIGID DUCTWORK SHALL BE SHEET METAL. B. TEST AND ADJUST ALL AIR HANDLING EQUIPMENT TO PROVIDE THE REQUIRED AIR VOLUME WITHIN 10% OF DESIGN CONDITIONS. TEST AND ADJUST ALL AIR DEVICES TO THE CFM SHOWN ON THE DRAWINGS. PROVIDE ALL CHANGES REQUIRED TO OBTAIN CFM QUANTITIES SHOWN ON THE DRAWINGS. TESTING AND BALANCING SHALL BE BY AN INDEPENDENT TEST AND BALANCING AGENCY IN ACCORDANCE WITH THE PROCEDURES OUTLINED IN THE TESTING AND BALANCING MANUAL AS PUBLISHED BY SMACNA. THE OWNER SHALL BE PROVIDED WITH THREE CERTIFIED COPIES OF THE AIR BALANCE REPORT BEFORE FINAL PAYMENT WILL BE MADE. C. FURNISH AND INSTALL ALL MECHANICAL EQUIPMENT AND OR AIR DEVICES AS SCHEDULED ON THE DRAWINGS. BIDS SHALL BE BASED ON THE EQUIPMENT SPECIFIED AND NO SUBSTITUTIONS WILL BE ACCEPTED. D. FURNISH AND INSTALL ALL SYSTEMS OF HVAC CONTROL (TO INCLUDE CONTROL WIRING) TO PROVIDE A COMPLETE SYSTEM. E. FLEX DUCTWORK SHALL NOT EXCEED 5' -0" IN LENGTH. FLEX DUCTWORK ALLOWED ONLY IN ACCESSIBLE AREAS PER CODE. ONLY ONE 90 DEGREE ELBOW ALLOWED N FLEXIBLE DUCTWORK. ELBOWS SHALL BE INSTALLED TO MAINTAIN A 1 --1/2" DIAMETER ENTERLINE RADUIS. FLEXIBLE DUCT NOT PERMITTED ABOVE GYP. BOARD CEILINGS OR IN INACCESSIBLE AREAS. F. ALL ROOF MOUNTED EQUIPMENT SHALL BE MOUNTED A MINIMUM HEIGHT OF EIGHT INCHES ABOVE THE EXPOSED ROOF MEMBRANE, PER THE LANDLORD'S REQUIREMENTS. PENETRATIONS TO ROOF OR NEW CURBS /FLASHING TO BE DONE BY MALL'S ROOFING CONTRACTOR. ALL EQUIPMENT ON ROOF TO HAVE PHENOLIC SIGN WITH TENANT NAME AND SPACE #. MECHANICAL SPECIFICATIONS 0 KI:: FURNISH AND INSTALL ADA COMPLIANT LAVATORY, (LAV -1), AMERICAN STANDARD 0356.421, WITH WALL BRACKET, GRID STRAINER, OFFSET P -TRAP. AMERICAN STANDARD #7501 -170 CENTERSET LAVATORY FAUCET. K FURNISH AND INSTALL 0.5 GAL., INSTANTANEOUS, 750W, 120V ELECTRIC WATER HEATER, (EWH -1), BELOW LAV. WATER HEATER SHALL BE INSINKERATOR MODEL UWL. O 4 FURNISH AND INSTALL FLOOR DRAIN, (FD ---1), ZURN MODEL Z- 453 -P WITH 7 "0 STRAINER & DEEP SEAL TRAP. 10 11 12 13 g 14 15 18 SPRINKLER HEAD IN TOILET ROOM. • FURNISH AND INSTALL ADA COMPLIANT WATER CLOSET, (WC -1), AMERICAN STANDARD MODEL 2377.100, OPEN FRONT SEAT LESS COVER. LOCATE WATER CLOSET CENTERLINE 18" FROM WALL, 1.6 GALLON TANK TYPE. LOCATE FLUSH HANDLE ON SIDE CLOSEST TO BATHROOM DOOR. VAV BOX, REFER TO SCHEDULE ON SHEET M2. MECHANICAL CONTRACT SHALL PROVIDE AND INSTALL DUCT SMOKE DETECTOR IN SUPPLY DUCT. COORDINATE INSTALLATION AND CONNECTION TO FIRE ALARM SYSTEM WITH LANDLORD. 3/4" CW LINE, CONNECT TO EXISTING CW LINE, PROVIDE AND INSTALL REDUCED PRESSURE BACKFLOW PREVENTER. VERIFY LOCATION IN FIELD. EXISTING MALL MAIN SUPPLY AND EXAUST DUCTS, FIELD VERIFY EXACT LOCATION AND SIZE. O 7 30 "x30" ACCESS PANEL FOR VAV -1, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. PAINT TO MATCH CEILING. ✓ FURNISH AND INSTALL NEW CEILING MOUNTED EXHAUST FAN, (EF-1), COOK MODEL GC -140, 100 CFM, 120V. ROUTE 6 "0 EXHAUST DUCT TO LANDLORD PROVIDED MAIN EXHAUST DUCT, VERIFY EXACT LOCATION IN FEILD. CONNECT SANITARY LINE TO EXISTING SANITARY MAIN, VERIFY EXACT LOCATION IN FIELD. CONNECT VENT LINES FROM WC -1, LAV-1 AND FD -1 TO EXISTING VENT STACK, VERIFY EXACT LOCATION IN FIELD FURNISH AND INSTALL SENSOR WITH AUTO CHANGEOVER FROM HEATING TO COOLING TO CONTROL VAV BOX. SPRINKLER SYSTEM SHALL BE MODIFIED AS REQUIRED TO SERVE THE NEW LAYOUT SHOWN ON THE DRAWING. NOTIFY THE MALL MANAGER 72 HOURS BEFORE SPRINKLER SHUTDOWN 15 REQUIRED AND PAY ALL MALL CHARGES FOR SPRINKLER SHUTDOWN. CONNECT TO THE LANDLORD'S EXISTING SPRINKLER LINE AND TO CONNECTIONS THAT EXIST IN THE SPACE TO ACCOMMODATE THE NEW SPRINKLER LOCATIONS. FURNISH AND INSTALL GALVANIZED STEEL DUCTWORK, SIZES AS NOTED ON DRAWINGS. DUCTWORK SIZES ARE CLEAR INSIDE DIMENSIONS. ALL NEW DUCTWORK SHALL HAVE 1" INTERNAL LINER. KEY NOTES VAV -1 1 bo ! I fI ?I 13 1 WC -1 ,�v, .,.. �.� �n„ .n.q� ., �. ..,Yr ,., r,,,,..s .., x,, nn�s • p., t_r „_ ,., a� . :-,..^.,.,,• 1.0-1 I T • lJ LAV+1 I 11 O L t 1 7 MECHANICAL o FIRE SPRINKLER & PLUMBING PLAN CONT. 1 x h 7 J F .” COVE S� 7,7. j 1` U c1.4 N PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louts, MO 63132 TEL 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: THIS DOCUMENT IS THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED As DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OP THIS DOCUMENT L5 NOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT* HEREBY ADVISED THAT TT t5 RREASED FOR USE UNDER THE FOLLOWING TERMS AND COMMONS, TEE DOCUMENT IS TO BE USED ONLY Di CONJUNCTION WITH TIPS PROJECT. REUSE OF ANY P ORUON OF THE DO CUMENT IN ANY OTHER CIRCUMSTANCE COHSTIMES COPYRIGNI INFRINGEMENT. THE DOCUMENT I5 FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES NOT CONSTNUTE AS-0ULT CONDITIONS. THE RECPI:TNT RETNHS THE OBLIGATION TO VERY THE CONDffbNS OF THE SUBJECT PROPERTY AND To COMPLETELY COORDINATE ALL DIMENSIONS, FAB RICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC. WITH RESPECT TO ALL ASPECTS OF TIE WORE EPOCH DEMON GROUP MAKES NO WARRANTY AS TO THE SUTTABIUTY OF THE DOCUMENT FOR THE RECPENT'S MENDED USE, TIE REFERENT sPEaFICAJLY AGREES TO WANE AND TO INDEMNIFY AND DEFEND ANY AND ALL CLAMS AGADIST EPOCH DESIGN GkOUP, ITS CONSULTANTS, ANY OF ITS RELATED ENTITIES, VENDORS, OR CONTRACTORS, FOR ANY LOSS INCURRED AS A RESULT OF PROFER OR IMPROPER USE OF TICS DOaµ1RNT. TFE RECPENT AGREES TO RETURN OR DESTROY TICS DOCUMENT UPON COMPLETIO_ • MOP WORK PERFORMED N - H THIS PROJECT, cr) rT 2 L.L. /OWNER /CITY CMNTS 01/10/08 1 L.L. / OWNER COMMENTS 12/14/07 No.Q Revision Description Date SHEET TITLE: RANDALLA. NELSON 8016 Reeder Rd. Lenexa, K5 66214 TEL: 913- 322 -5150 FAXI 913- 322 .5155 RECEIVED CITY OF I UKWIL.A .IAM 1 7 77111 t -'cnMI I l../ Ixd 1 tti MECHANICAL FLOOR PLAN PROJECT NO.: SHEET NUMBER: 07073 DRAWN BY: JCC ISSUE DATE: 11/13/07 Mi 4 P pkWW4 Cr L,a o � .� — 0 NN Lii Ui 0 T a U W 1 — Q � v 0 W W Pm-4 ' o 0 z :a PROJECT TEAM: Architect: Epoch Design Group, Inc 1 155 Olivette Exec Pkwy. Suite 100 St. Louis, MO 63132 TEL 314.721.1340 FAX 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL 913 - 322 -5150 FAXI 913-322-5155 THIS DOCJMENT LS THE PROPERTY OF EPOCN DESIGN GROUP, coPYRIGHTED As DATED. All RIGHTS RESERVED. AUTHoP ZATON FROM EPOCH DESIGN GROUP FOR use OF nu DOCUMENT IS NOT TRAN.SFERA TLA THE REarENT OF THIS DOCUMENT IS HEREBY ADVISED THAT IT is RELEASED FOR USE TINDER TIE FOLLO WING TERMS AND COHDHIONS, THE DONMLNT Is TO BE USED ONLY IN co NJUNCTION WITH This PROJECT, REUSE OF ANY PORTION OP THE DONMENT N ANY OTHER CSIOJMSTANC: CONSTTTUTES COPYRIGHT BJFENGEMENT, ThE DOCUMENT TS FOR DESIGN INTENT AND INFORMATION ONLY AND DOES HOT CONSTITUTE AS-BUILT CANDTIONS. THE RECPENT RETAINS THE OBLIGATION TO VERIFY THE COmoEIONS O F THE SUBJECT PROPERTY AND TO COMPLETELY co oWROTE All DN.H7sIOHS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT To AIL ASPECTS OF THE WORK EPOCH DESIGN GROUP MAKES NO WARRANTY As TO THE SI*TANUrf OF THE DOCUMENT FOR THE RECPENT'S WENDED USE. THE REPENT sPEaNCAJLY AGREES To WAVE AND To INDEMNIFY AND DEFEND ANY AND ALL GUMS AGANST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED D1TITES, VENDORS, OR CONTRACTORS, FOR ANY Loss INCURRED As A RESIAT OF PROPER OR IMPROPER USE OF n#5 DOCUMENT. Ll-I' I 1 L..)UC.I "TT/ r1C TI K A /ILP f�i- Fi 1V1►1 U ENITER W V) 2 L.L. /OWNER /CITY CMNTS 01/10/08 1 L.L. / OWNER COMMENTS 12/1.4/07 No.a Revision Description Dote SHEET TITLE: HVAC SPECIFICATIONS AND DETAILS PROJECT NO.: SHEET NUMBER: 07073 DRAWN BY: JCC ISSUE DATE: 11/13/07 M2 TRANSITION TO BRANCH SI SIZE All Ni RADIUS ELBOW SINK OR LAV, WATER HEATER HOT AQUA ----- FLOW CONTROL • 1.5D �` 1111111 • 5 GPM z' .. E` �_.__. LOCK NUT SUPPORT ANGLES AND STIFFENERS TO BE SUPPLIED AND INSTALLED BY M.C. 1 PROVIDE A SUPPORT ANGLE SPANNING TWO OR MORE JOISTS; MODEL 35 --208 SINGLE PHASE EWH - 1 1 � COLD W 3 X 3 X 1/4 " " SUPPORT ANGLE WHERE JOIST SPACING IS OVER 2 —0 BUT NOT MORE THAN 4' -0 ". PROVIDE 2 X 2 X 1/4" SUPPORT ANGLE WHERE JOIST SPACING IS 2' -0" AND UNDER. WHERE LOAD EXCEEDS 500 POUNDS PER HANGER, SEE STRUCTURAL DRAWINGS FOR DETAILING. 15 DEG DEPTH D MAIN DUCT OF BRANCH DUCT f LARGE WASHER !y BOTTOM CHORD 2 FIELD WELD, PROVIDE STIFFENER ANGLE WHERE LOAD BEING HUNG EXCEEDS 250 LBS. IO _a LATE TRANSITION TO BRANCH 3 r (DUAL OUTLET) — ~ 1 / 2 1 -1/2 x 3/16 " ? SIZE _Nam SQUARE VANED • OF JOIST L , LARGE WASHER ' o ELBOW x FIN. FLOOR STIFFENER 3 30 DEG THIS DET IL 1 SUPPORT ANGLE "� LOCK NUT 1/2 BOLT J — BOX (BYE LEG. PANEL . LOCK NUT LARGE WASHER BOOM "' LARGE �J TURNING VANES LOCK NUT HANGER ROD POINT CONTRACTOR) OFTJOISTCHORD LOCK NUT BRANCH • DUCT FULL DEPTH OF MAIN DUCT TRANSITIONS 1 -. ,- ,' Q ,;. ��, �i ;, HANGER ROD c d 1 THIS METHOD ALLOWABLE FOR MAX. 150 LB. LOAD WITHIN 6" OF PANEL POINT; BEYOND 6 OF PANEL POINT :._ . :. :. # I ... : -:. iI 6 " ::: ::... LLL I HANGER ROD IL' NOTES: 50 LB. MAX. LOAD ALLOWABLE. WHEN MULTIPLE PIPES /DUCTWORK ARE PERPENDICULAR TO JOISTS, HANGERS SHALL BE STAGGERED SO THAT 6" r LARGE WASHER LOCK NUT 1/2 "? BOLT BOTTOM CHORD OF JOIST ANGLE SECTION NOTE: POINT OF USE WATER HEATER SHALL BE POSITIONED SO AS NOT TO ENCROACH INTO ANY REQUIRED WHEELCHAIR ACCESS CLEARANCES BENEATH THE LAVATORY AND SHALL BE SHEILDED AGAINST HUMAN CONTACT >. 1 SUPPORT 1. DETAIL IS APPLICABLE TO SUPPLY AIR BRANCH DUCT TAKE-OFFS. Q SECTION BRANCH DUCT SIDE TAP PIPING /DUCTWORK IS NOT SUPPORTED THIS FROM A SINGLE JOIST. DETAIL f A THIS �� IL N.T.S. THIS `ET IL N,T,S, POINT OF USE WATER HEATER DETAIL BRANCH DUCT TAKEOFFS AND TRANSITIONS TYPICAL JOIST HANGER DETAIL FOR PIPING, DUCTWORK, AND EQUIPMENT NO SCALE NO SCALE 10 DETAILS A ? A. PROVIDE ALL LABOR AND MATERIAL FOR A COMPLETE PLUMBING SYSTEM AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING BID. B. FURNISH AND INSTALL STANDARD WEIGHT CAST IRON SOIL PIPE WITH "NO-HUB" FITTINGS FOR ALL WASTE AND VENT PIPING ABOVE GRADE AND SERVICE WEIGHT CAST IRON PIPING WITH APPROVED COMPRESSION JOINTS UNDER FLOOR. C. INTERIOR WATER PIPING ,ABOVE THE FLOOR SHALL BE' TYPE L ABOVE GRADE = AND TYPE K BELOW GRADE WITH 95 -5 SOLDERED JOINTS. VALVES SHALL 8E ;` ` Neu.) S=590 BALL VALVES OR EQUIVALENT. TEST WATER PIPING TO 125 LBS. FOR AT LEAST TWO HOURS WITH NO LEAKS BEFORE COVERING. INSULATE HOT AND COLD PIPING ABOVE THE FLOOR WITH 1" THICK FIBERGLASS TYPE WRAP AROUND INSULATION WITH ALL SERVICE JACKET. D. ALL PENETRATIONS OF FLOOR SLAB SHALL BE SAW CUT, GROUTED, AND SEALED WAT PROOF, COORDINATE ALL SLAB DEMOLITION WITH LANDLORD PRIOR TO WO E. CAP ALL UNUSED PLUMBING LINES ASSOCIATED WITH LEASED SPACE AS REQUIRED BY LANDLORD AND LOCAL INSPECTION AUTHORITIES. . FURNISH AND INSTALL A BACKFLOW PREVENTER PER MALL CRITERIA, IF FLDDR REQUIRED. G PVC PIPING NOT PERMITTED PLUMBING FIXTURE S C H E D U L E DESCRIPTION MANUFACTURER /CATALOG N0. WC -1 AMERICAN STANDARD "CADET" 16 1/2" HIGH ELONGATED (BARRIER FREE) 1.6 GPF, PRESSURE ASSISTED TOILET. 42377,100 (BOWL 43109.016, TANK 44098.100, SEAT "LAUREL" #5311.012). 3 / 4" ■■ ROOF LINE 3 3/4" ir j 2" 2° FURNISH AND INSTALL TRAP PRIMER FOR FLOOR DRAIN LINE 4 + LAV- -1 AMERICAN STANDARD WALL HUNG (BARRIER FREE) LAVATORY #0356.421 WHITE, FAUCET: 7501 -170, 0.5 GPM WITH WRIST BLADE HANDLES AND GRID STRAINER. EWH-1 INSINKERATOR MODEL # UWL, 0.5 GALLON, INSTANTANEOUS, 750W, 120V ELECTRIC WATER HEATER, INSTALLED UNDER SINK. i LAV -1 © D 3/4" WC-1 FD - 1 WC > EWC -1 ' HALSEY TAYLOR, MODEL # HAC8FS -Q. STAINLESS STEEL, 8 GPH, 400 WATT, 120 V / 1 PHASE 60 HZ. WITH 1 2 COLD WATER CONNECTION AND 2" WASTE CONNECTION. MEET ADA REQUIREMENTS WHERE REQUIRED BY AHJ. 2 .. °t C� COM PLIe, " p ' • �'� "- :- ''�;°� " ' a te - _ � ._ _ L 1/2" L - 1 /2" WATER 4i 1/2" .. RISER DIAGRAM FLOOR LINE ..._... _ _....... 3 " " ; � 4 4" ; WASTE RISER DIAGRAM 1 PLUMBING 5 RISERS 13 PLUMBING SPECIFICATION 12 PLUMBING SCHEDULES TRANE HVAC " E IF E T PACKAGE At E EQUIPMENT PACKAGE C LL'DES ALL MANE NE HNC EQUIPMENT AND RELATED ACCESSORIES SUCH AS CURBS, THERMOSTATS. HEATERS, ETC., AS SPECIFIED ON THE PLANS AN SPECIFICATIONS FOR. CUSS'S INCORPORATED FOR COMPLETE INFOR2TUTION ON TTr� QL 'ME1°;L PACKAGE CONTACT THE TRANE NATIONAL ACCOUNT EX C:L1 n E AT TRANE NATIONAL ACCOUNTS _ PAIF1C BRO SON TRANE NATIONAL ACCOUNTS 17760 ROW ND .STREET CI r OF NDUSTRr', CA 81743 I?O? (626)435-1176 _ DP= 1 rr TOLL FREE : (S• ) 332 -16 ASS /STA l i': TOM CALLAGHAN PHONE: (626)4'35-1131 —DIRECT ? 1~'` FAX: (626)913-2429 7MAIL FERONS.!lN&T ANTz.CQM u[ ICA LLAGH Nttt.. s RANE .COM S VAV TERMINAL UNIT WITH ELECTRIC REHEAT SCHEDULE MARK SERVICE MANUFACTURER MODEL NOMINAL CFM MAX INLET S.P COOLING CAPACITY HEATING CAPACITY ELECTRICAL NOISE CRITERIA NOTES CFM EAT LAT TOTAL (MBH) CFM EAT LAT MBH KW MCA MOCP V /PH /HZ DISCHARGE RADIATED MAX MIN VAV -1 LL AHU TRANE _ VS,EF - 16 _30.0.0_ .... 0.75 3000 2000 55 55 64.6 2000 55 75 51.2 15 28.4 30.00 277/ 1 /60 20 34 A. B VAV -2 1 LL AHU TRANE , VSCF -10 1000 ; 0.75 1000 500 55 55 21.5 NA NA NA NA NA 2 15 ,F277/1/601,'. 20 34 A, 8 _- 4 _ a .... ... _ _ r .._ .._ . ... _..._ ._.._ NOTES: A. PROVIDE WITH HANGER BRACKETS AND SUSPEND FROM STRUCTURE WITH ALL THREAD HANGING ROD. B. PROVIDE WITH FACTORY INSTALLED DISCONNECT SWITCH .. CHANGES ;, IOty OT OE1G AL � �7 PACKAGE T T WOULD > f -17-12' HVAC EQUIPe Et'`TT PACKAGE SHOULD BE BROUGHT TO THE ATTENTION OF THE ACCOLNT Ex_cuTDCE AT iFW_LE a%TlONALACCOrN,`TS. NOTE: O E G PROCEDURE TIM GENERAL CONTACTOR OR Mi;CHANTC'AL CONTRACTOR PURCHASES Ti= ' EQLsr:ME PACKAGE DaECTLY =ROT TIM TRANE NATIO :UAL ACCOUNTS SALESMAN. PATRICK BRONSON. TIM H\ AC CO 4T AC. TOR WILL EE PESPONSsBLE FOR SST YEAR LABOR WARRANTY DELIVERY COORDINA.'rIO N, RECEDING AND (STALL TION 4S DES TED i T IIF SPEC C. TIONS. N PARIS WARRANTIES GRILLE, REGISTER, AND DIFFUSER SCHEDULE 2 MARK MANUFACTURER MODEL FACE TYPE MOUNTING LOCATION FACE SIZE (IN MAX (NC) NOTE Si TITUS FL -20 HT SLOT SURFACE 48 28 B,C S2 TITUS 300RL LOUVERED DUCT 12 "x8" 28 A,B,D S TIT 5 OMNI 0 R D RFAC 1 "X1 " 4 A B D S4 TUTUS OMNI LOUVERED LAY —IN 24 "x24" 24 A,B,D R1 TITUS 350RL LOUVERED SURFACE _ x24" _ -- B NOTES: A. AIR DEVICE RUN —OUT SHALL BE SAME SIZE AS DIFFUSER NECK. B. AIR DEVICE COLOT TO MATCH CEILING COLOR C. PROVIDE WITH FACTORY PLENUM CONNECTION. D. PROVIDE WITH INLET DAMPER. TP &NE w ?.R.PAN1 TES ALL PARTS FOR. A PERIOD OF ONE (I) YEAR FROM NITIAL STARTUP OR 13 MONTHS FROM DATE OF S I','E T, WHICHEVER OCCURS MST. CERTAIN EQUWM NT COMPONEiw HAVE AN EXTENDED WA 4.NTY LONGER THAN ONE (1) YEAR TRANE PANS WARRANTIES BELONG TO TEE EQLIPMEN OWNER 20 HVAC SCHEDULES 4 P pkWW4 Cr L,a o � .� — 0 NN Lii Ui 0 T a U W 1 — Q � v 0 W W Pm-4 ' o 0 z :a PROJECT TEAM: Architect: Epoch Design Group, Inc 1 155 Olivette Exec Pkwy. Suite 100 St. Louis, MO 63132 TEL 314.721.1340 FAX 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL 913 - 322 -5150 FAXI 913-322-5155 THIS DOCJMENT LS THE PROPERTY OF EPOCN DESIGN GROUP, coPYRIGHTED As DATED. All RIGHTS RESERVED. AUTHoP ZATON FROM EPOCH DESIGN GROUP FOR use OF nu DOCUMENT IS NOT TRAN.SFERA TLA THE REarENT OF THIS DOCUMENT IS HEREBY ADVISED THAT IT is RELEASED FOR USE TINDER TIE FOLLO WING TERMS AND COHDHIONS, THE DONMLNT Is TO BE USED ONLY IN co NJUNCTION WITH This PROJECT, REUSE OF ANY PORTION OP THE DONMENT N ANY OTHER CSIOJMSTANC: CONSTTTUTES COPYRIGHT BJFENGEMENT, ThE DOCUMENT TS FOR DESIGN INTENT AND INFORMATION ONLY AND DOES HOT CONSTITUTE AS-BUILT CANDTIONS. THE RECPENT RETAINS THE OBLIGATION TO VERIFY THE COmoEIONS O F THE SUBJECT PROPERTY AND TO COMPLETELY co oWROTE All DN.H7sIOHS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT To AIL ASPECTS OF THE WORK EPOCH DESIGN GROUP MAKES NO WARRANTY As TO THE SI*TANUrf OF THE DOCUMENT FOR THE RECPENT'S WENDED USE. THE REPENT sPEaNCAJLY AGREES To WAVE AND To INDEMNIFY AND DEFEND ANY AND ALL GUMS AGANST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED D1TITES, VENDORS, OR CONTRACTORS, FOR ANY Loss INCURRED As A RESIAT OF PROPER OR IMPROPER USE OF n#5 DOCUMENT. Ll-I' I 1 L..)UC.I "TT/ r1C TI K A /ILP f�i- Fi 1V1►1 U ENITER W V) 2 L.L. /OWNER /CITY CMNTS 01/10/08 1 L.L. / OWNER COMMENTS 12/1.4/07 No.a Revision Description Dote SHEET TITLE: HVAC SPECIFICATIONS AND DETAILS PROJECT NO.: SHEET NUMBER: 07073 DRAWN BY: JCC ISSUE DATE: 11/13/07 M2 ELECT RICAL ��»*�� ���� ��� � POWER � �� � �� �~ �� N *� ���8 ^�`� 1.7777.7CAMM PP 27 PP 16 TO BUZZER IN STOCK ROOM pp • • ' ~_'*~�~" [. | 77, 23 PP PP PANELBOARD 'LP' PANELBOARD 'PP' TRANSFORMER 'T1' ��------- PANELBOARD "HP' 11 � 1Y i ` . ^� '�� 1 / '� rr p�n r ( p p - . ,--''. 9 .. orb Loret- 1 , - .„„ .7, • 1:1 • 4122.11112DIANSWPATArTIVT. ^ PROVIDE (2) 1"C TO COMM. STRUCTURE —' � ����� ~Y ~' } U l' A / � � | � U � � ./ : , x ` `u ^ � } 1 un2. `__ _____ • nr VAV-1 -�-J-___----� / } � ) - r - : � > � � k i A __-_-- • . -7. _ � �� 5 PP | � �� �|l�^� ~~~ '- '- - ' r� , i i \ �---—/ , �''���^' AT ou//��" ~^. �~ PUSH- DOOR BUTTON IN CASHWR AP __ -___--�-__'-_� r 8 HP 35 pp TO CHIME IN STOCK ROOM PP 24 COMMUNICATION STRUCTURE ------ ��P��� |� |||||| TO PUSH- |||||| - ...... BUTTON AT REAR DOOR eFF19 ., _ PP-1O volt |G 1 1 1 1 1 1 1 1 /||||| ...... 2 3 4 5 7 8 � U 8 14 18 PP-14 111 PROVIDE POWER FOR FRONT CASHWRAP RECEPTACLES ROUTED FROM JUNCTION BOX CASHWRAP STUB UP. PROVIDE RECEPTACLES WITHIN CASEWORK AT LOCATIONS COORDINATED WITH CASEWORK CONTRACTOR. VERIFY CONDUIT ROUTING WITHIN CASEWORK FIELD VERIFY EXACT FEED LOCATION FROM WALL, DUPLEX RECEPTACLE FOR MICROWAVE MOUNTED AT +42" AFF. COORDINATE EXACT LOCATION. DUPLEX RECEPTACLE FOR REFRIGERATOR MOUNTED AT +15" AFF. COORDINATE EXACT LOCATION. GFCI RECEPTACE FOR RESTROOM SINK AT +42" AFF. COORDINATE EXACT LOCATION. GEC! RECEPTACE FOR INSTANTANEOUS WATER HEATER. SEE MECHANICAL DRAWINGS FOR MORE INFORMATION. L TENANTS CONTRACTOR TO FURNISH _i YY0H EQUIPMENT AS FOLLOWS: & PUSHBUTTON ---- EDWARDS IN CASHWRAP. B. BUZZER EDWARDS CEILING AND IN CASHWRAP. C. TRANSFORMER EDWARDS D. CHIME EDWARDS � � AND INSTALL SERVICE DOOR/ SIGNAL #852. MOUNT _, AND ~'~' #340A G5. MOUNT IN STOCKROOM MOUNT AT +8'-0 AFF #338-G5. MOUNT AT f8 AFF PROVIDE 20 AWP, 110 VOLT JUNCTION BOX AND DEDICATED DUPLEX RECEPTACLE (WITH ISOLATED GROUND) FOR ANTENNA DIRECTLY ABOVE DOOR. JUNCTION BOX NEEDS 1" CONDUr[ WITH A PULL STRING TO RUN TO THE COMM. STRUCTURE. COORDINATE EXACT LOCATION. FLUSH JUNCTION BOX AT +42 AFF WITH 3/4" CONDUIT WITH PULL STRING TO CEILING SPACE FOR ROBBERY ALARM PAD. COORDINATE EXACT LOCATION AND OTHER RELATED ELECTRICAL REQUIREMENTS. 20 AMP RATED JUNCTION BOX WITH ISOLATED GROUND ABOVE CEILING FOR SENSORMATIC SYSTEM. THE AC SOURCE MUST BE A 3 WIRE 24 HOUR UNSWITCHED OUTLET WITH LESS THAN 0.8 VAC BETWEEN NEUTRAL AND GROUND. PROVIDE 'LOCK-ON' DEVICE ON BREAKER AT PANEL. PROVIDE 1" OR CONDUIT FROM POWER RACK ABOVE CEILING DOWN TO EACH ANTENNA IN FLOOR. CONDUIT RUN CANNOT EXCEED 30 FEET AND MUST BE HIDDEN IN WALL. VERIFY EXACT SPECS WITH SENSORMATIC ELECTRONIC CORPORATION C/O ED ENGLAND AT 800-297-1442. POWER PLAN KEYED NOTES ��� ����M� ����U�� �����U� ���� �U�-� SCALE: N/A / -� '�_ ~�~~ ���~�~~~�� � � � 7 , , 7 ` ' /^ 761 / 11 12 13 14 15 17 18 19 20 21 22 / _ 7.7� - — —'- ' — � ����F' ,'����" .--" ° 7,7f { SENSORMATIC FL OR SENSORS H tow ���� .������� -` ����������� - '-'","--•" • ` �����" • ,- `���"'''.~~ ~^• .7,.. ^.,,,,,....„, .,...^. ~ Oh ■ ily _ H JUNCTION BOX FOR RS-232 PLATE AT 6" AM 16 m PROVIDE PHONE JACK AT 8'-0" AFF AT LOCATION SHOWN. r - "M 3.2J � `^ t � A77 g. • ROUTE CIRCUIT THROUGH AUTOMATIC TIME CLOCK CONTROLLED LIGHTING CONTACTOR. SEE AUTOMATIC CONTROLS DETAIL ON SHEET E3.0. = h/ xLl | / v! � f 'N �/ 077 / g U "70 /� '° v/ � �� -� 8 � ' ., ° —.��,"~- °m`�~.� / � � ~ / /��n��'�°',~wx�� �� �~�°. �_��v ,-,.4:,.."\ ~_ � � �� : ��. ��/���~-~� . "` - ~\� -'-- r ' ' '— - SHOPPER TRACK SINGLE ORBIT 2 JUNCTION BOX. GENERAL CONTRACTOR SHALL PROVIDE ( ) 1"c AND (1) CATEGORY 5 CABLE FROM JUNCTION BOX TO COMM. STRUCTURE. RJ JACK FOR SHOPPER TRACK TO BE ABOVE CEILING. VERIFY EXACT LOCATION OF SHOPPER TRACK JUNCTION BOXES AND CABLING REQUIREMENTS WITH GUESS PROJECT MANAGER PRIOR TO ROUQH-|N, EMBEDDED DOOR CONTACTS AND DOOR ALARM CONTACT MOUNTED ON HEAD OF DOOR FRAME WITH MAGNET MOUNTED IN TOP OF DOOR AT BACK OF HOUSE. PROVIDE JUNCTION BOX ABOVE CEILING WITH 1/2" CONDUIT STUBBED INTO HEAD OF DOOR FRAME. SENSORMATIC ALARM BOX MOUNTED ON THE CEILING. VERIFY AND COORDINATE EXACT LOCATION AND OTHER RELATED ELECTRICAL REQUIREMENTS WITH GUESS PROJECT MANAGER PRIOR TO ROUGH-IN. ALL CONDUIT SHALL BE HIDDEN FROM PUBLIC VIEW. PROVIDE 12 FIRE RATED PL/WOOD TELEPHONE BACKBOARD ABOVE IFS. PROVIDE #G AWG GROUND WIRE TO SERVICE GROUND ELECTRODE. MOUNT GROUND TERMINAL AND RECEPTACLE AT UPPER LEFT HAND SIDE OF BACKBOARD. CONNECT THE GROUND WIRE TO THE BUILDING STEEL OR COLD WATER PIPE. SAW CUT FLOOR FOR INSTALLATION OF CONDUITS TO CASHWRAPS. PATCH FLOOR TO MATCH SURROUNDING FLOOR AREA. PRIOR TO SAW CUTTING, PERFORM FLOOR X-RAYING WITH LANDLORD PRIOR APPROVAL AND CONFIRM WITH LANDLORD SAW CUT LOCATION EXISTING UTILITIES. GENERAL CONTRACTOR TO RUN 1/2" CONDUIT WITH PULL STRING DOWN IN WALL FOR FLOOR MOUNTED SENSORMATIC UNITS. EXTEND CONDUIT UP TO CONTRLLER MOUNTED ABOVE CEILING. GENERAL CONTRACTOR TO COORDINATE WITH SENSORMATIC. PROVIDE POWER FOR FRONT CASHWRAP RECEPTACLE AND LIGHTS ROUTED FROM JUNCTION BOX CASHWRAP STUB UP. PROVIDE RECEPTACLES WITHIN CASEWORK AT LOCATIONS COORDINATED WITH CASEWORK CONTRACTOR. VERIFY CONDUIT ROUTING WITHIN CASEWORK, FIELD VERIFY EXACT FEED LOCATION FROM WALL. PROVIDE (3) JUNCTION BOXES MOUNTED AT 39 1/2" AFF 58 1/2" AFF AND 77 1/2" AFF. PROVIDE (1) 20A. 1 PHASE, 120V GROUNDING TYPE RECEPTACLE HUBBLE #5382 AND FLUSH FLOOR BOX HUBBLE #32422-(2)53825' PROVIDE DUCT SMOKE DETECTOR AND CIRCUIT AS SHOWN. CONNECT TO FIRE ALARM SYSTEM AS REQUIRED. TENANT WORK GENERAL REQUIREMENTS TENANTS SHALL PROVIDE THE FOLLOWING: • EXTEND, AS REQUIRED WITHIN THE DEMISED 9REM|SBS, THE ELECTRICAL SERVICE FEEDER TO TENANT'S MAIN DISCONNECT SWITCH OR MAIN CIRCUIT BREAKER EQUIPPED PANEL BOARD. • TENANT'S ELECTRICAL SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH LANDLORD'S CRITERIA AS OUTLINED IN THIS WANUAL, THE LATEST ADOPTED EDITIONS OF THE NEC AND THE REQUIREMENTS OF ALL LOCAL AUTHORITIES HAVING JURISDICTION. WATER|ALS, ELECTRICAL PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS SHALL BE NEW AND APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS. • TENANT SHALL INSTALL ALL ELECTRICAL WORK NECESSARY FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM WITHIN THE PREMISES, INCLUDING, WITHOUT LIMITATION, TRANSFORMERS, ELECTRICAL PANELS, DISCONNECT SWITCHES, ETC. CONDUIT AND 1 : ALL MAIN FEEDER WIRES FROM THE MAIN ELECTRICAL SWITCH SHALL BE SIZED TO MEET THE MINIMUM FUSE PROTECTION CAPACITY OF TENANT'S MAIN ELECTRICAL CIRCUIT BREAKER. MAIN SERVICE FEEDERS, AS A MINIMUM, SHALL BE TREATED FOR THE SUM OF ALL LOADS, PLUS TWENTY-FIVE PERCENT (25%) SPARE CAPACITY. BRANCH CIRCUITS CONNECTED LOADS SHALL NOT EXCEED EIGHTY PERCENT (GO%) OF RATED CAPACITY. 2 • MINIMUM CIRCUIT WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING. ALL MAIN AND BRANCH CIRCUITRY WIRING SHALL BE COPPER. ALL WIRING IS TO HAVE 600-VOLT INSULATION, TYPE TW, THW, THWN OR THHN FOR MAIN FEEDERS. SAME COLOR SHALL IDENTIFY SAME PHASE THROUGHOUT THE SYSTEM. 3 : AT NO TIME CAN FLEXIBLE CONDUIT BE USED AS COMMON ROUTING FOR WIRES. 4 ; PANEL CONNECTED LOADS WITHIN THE TENANT SPACE AND MAIN FEEDER CONDUCTORS (FROM LANDLORD SWITCHGEAR TO SHALL BE BALANCED WITHIN PLUS OR MINUS TEN PERCENT (10%) ACROSS ALL PHASES. 5 : ALL CONDUITS SHALL BE CONCEALED IN FINISHED AREAS. MINIMUM CONDUIT SHALL BE ONE-HALF INCH (1/2") ' DIAMETER AND CONCEALED IN SLAB SHALL BE THREE-QUARTER INCH (��4"�. NO CONDUIT IS ALLOWED TO NECESSARY. IN THE SLAB UNLESS ABSOLUTELY NECE�SA� COORDINATE ALL IN SLAB WORK WITH LANDLORD'S STRUCTURAL ENGINEER. 6 : ALL WIRING SHALL BE INSTALLED IN CONDUIT. CONDUIT SHALL BE GALVANIZED STEEL, RIGID HEAVY WALL OR ELECTRICAL METALLIC TUBING. WATERTIGHT FITTINGS SHALL BE USED WHERE REQUIRED BY CODE. 7 : CONDUIT HANGERS, CLAMPS, LIGHT F|%TURESUPPORT8 ETC SHALL BE FASTENED TO BAR JOISTS OR BEAMS. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. EXPOSED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST THREE INCHES (3") FROM WATER OR GAS LINES, WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. 8 : FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION FOUR FEET 0^1 MAXIMUM LENGTH, MINIMUM ONE-HALF INCH (1/2") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. NO 8X, AC, MC OR ROMEX TYPE WIRING CAN BE ALLOWED. FURNISH LIQUID-TIGHT FLEXIBLE CONDUITS FOR OUTDOOR INSTALLATIONS AND FLOOR BOXES SHALL BE WATERTIGHT WITH CAST THREADED CONDUIT HUBS. 9 PULL BOXES OR JUNCTION BOXES ARE REQUIRED TO BE OF MINIMUM TWELVE- (12) GAUGE GALVANIZED STEEL. BOXES IN WALLS SHALL BE GALVANIZED PRESSED STEEL OR CAST METAL. CAULK AROUND BOXES TO ELIMINATE NOISE TRANSMISSION. 10 : THE ELECTRICAL SYSTEM SERVING THE TENANT SPACE SHALL BE GROUNDED IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE NEC. 11 : GROUND FAULT CIRCUIT INTERRUPTERS SHALL BE INSTALLED IN BRANCH CIRCUITS, WHERE REQUIRED BY CODE. 12 : PRIOR TO MAKING ANY CUNDU[F, PIPE OR DUCT-ROOF PENETRATION AND/OR POSITIONING ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND/OR PENETRATIONS SHALL MATCH LOCATIONS, AS INDICATED ON THE LANDLORD-APPROVED PLANS AND BE APPROVED BY LANDLORD'S ON-SITE REPRESENTATIVE. 13 : ALL TENANT EQUIPMENT ON THE ROOF SHALL BE LABELED WITH TENANT NAME AND SUITE NUMBER. ALL TENANT EQUIPMENT MUST BE LOCATED IN THE LANDLORD APPROVED LOCATION. ALL ROOF PENETRATIONS SHALL BE MADE AT THE TENANT'S EXPENSE BY A LANDLORD APPROVED ROOFING CONTRACTOR PER THE LANDLORD SPECIFICATIONS. ALL WATERPROOFING SHALL BE DONE AT THE TENANT'S EXPENSE BY A LANDLORD APPROVED WATERPROOFING CONSULTANT PER THE LANDLORD SPECIFICATIONS. ON COMPLETION OF INSTALLATION, TENANT SHALL OBTAIN AT THE TENANT'S EXPENSE, A SPECIAL INSPECTION SIGN-OFF FROM THE LANDLORD'S DESIGNATED ROOFING CONTRACTOR AND SHALL DELIVER PROOF OF SIGN-OFF TO THE LANDLORD TENANT COORDINATOR REPRESENTATIVE ON SITE. ELECTRICAL PANELS 1 : AS REQUIRED, PROVIDE LOCK-ON DEVICES ON PANEL CIRCUIT BREAKERS FOR E%[[ AND EMERGENCY LIGHT AND FIRE/SMOKE ALARM SYSTEM. 2 : FURNISH A COMPLETE TYPEWRITTEN IDENTIFICATION DIRECTORY CARD FOR ALL MAIN AND BRANCH CIRCUITS IN THE PANEL DOOR. MISCELLANEOUS ITEMS: 1 : DRY TYPE TRANSFORMER NOISE LEVEL IS LIMITED TO A MAXIMUM OF FIFTY (50) DB AVERAGE, MEASURED AT A DISTANCE OF ONE FOOT (1'-0~\ FORM THE CASE, PER NEMA PUBLICATION NO. TR- 1-1980 OR LATEST REVISION THEREOF. 2 : AS REQUIRED BY GOVERNING CODES, FURNISH SELF-CONTAINED, BATTERY PACK EMERGENCY LIGHTING AND EXIT SIGNS THROUGHOUT THE DEMISED PREMISES. 3 : PROVIDE WEATHERPROOF DISCONNECT 8VV|TCH, 120 VOLT DUPLEX SERVICE OUTLET AT EACH ROOF-MOUNTED HVAC UN[[' 4 : ALL DEVICES AND EQUIPMENT IN FINISHED AREAS SHALL BE FLUSH MOUNTED, WHERE POSSIBLE. 5 : NO LIGHTING CAN BE INSTALLED OUTSIDE THE TENANT SPACE, IN THE COMMON AREA AND/OR CEILING FOR STOREFRONT LIGHTING OR SIGN ILLUMINATION. 6 : TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE-EIGHTH INCH /1/8"\ THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1") WITH ONLY THE TENANTS SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. 7 : TENANT SHALL PROVIDE AND INSTALL COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT IS TO BE CONTAINED WITHIN THE TENANT'S SPACE. LANDLORD SHALL PROVIDE ONE THREE-QUARTER INCH (3/4") E CONDUIT FROM . . ' ^ LANDLORD'S TELEPHONE EQUIPMENT ROOM TO TENANTS DEMISED SPACE. EXTENSION OF LANDLORD-PROVIDED CONDUIT TO TENANT'S TELEPHONE EQUIPMENT |8 THE RESPONSIBILITY OF THE TENANT. TENANT SHALL MAKE APPLICATION TO THE SERVING TELEPHONE COMPANY FOR SERVICE AND SHALL COMPLY WITH THEIR REQUIREMENTS. TENANT'S TELEPHONE EQUIPMENT IS NOT PERMITTED IN LANDLORD'S TELEPHONE EQUIPMENT ROOM. 8 : TENANT'S HVAC SYSTEM SHALL BE POWERED OFF TENANT'S ELECTRICAL DISTRIBUTION SYSTEM. TENANT SHALL PROVIDE ALL POWER AND CONTROL WIRING, INCLUDING FINAL CONNECTION. 9 : TENANT'S LIGHTING AND LIGHTING CONTROL SYSTEM SHALL COMPLY WITH THE WASHINGTON STATe NON-RESIDENTIAL ENERGY CODE. FIRE ALAR LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. THE TENANT SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR FOR DESIGN AND PROGRAMMING. SYSTEM DESIGN A CENTRAL FIRE ALARM SYSTEM - COORDINATE SYSTEM MANUFACTURER AND MODEL WITH LANDLORD. • ALL NEW AND RELOCATING TENANTS SHALL BE CONNECTED TO AND SHALL COMPLY WITH ALL REQUIREMENTS OF LANDLORD'S NEW FIRE ALARM SYSTEM. LANDLORD WORK: LANDLORD SHALL PROVIDE A FIRE ALARM 8Y3TEM, AS FOLLOWS: • A CENTRAL ADDRESSABLE, VOICE EVACUATION TYPE, FIRE ALARM SYSTEM SERVING THE ENTIRE MALL. • LANDLORD WILL PROVIDE A RED FIRE ALARM JUNCTION BOX IN THE CORRIDOR WITH A 3/4 CONDUIT STUBBED INSIDE DEMISED TENANT SPACE FOR TENANT'S FIRE ALARM SYSTEM DEVICES. JUNCTION BOX WILL BE PROVIDED WITH FIRE ALARM ANNUNCIATION AND INITIATION CABLING AND TERMINAL BLOCKS. • LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT THE TENANT'S SOLE COST AND EXPENSE. TENANT WORK : GENERAL REQUIREMENTS 1 : TENANT SHALL INSTALL WITHIN TENANT'S PREMISES A FIRE ALARM SYSTEM OR COMPONENTS AS DELINEATED THROUGH DESIGN DOCUMENTS ISSUED BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR (AT TENANT'S EXPENSE). 2 : PROVIDE WIRING IN ACCORDANCE WITH NEC, NFPA AND AS REQUIRED BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR AND ANY LOCAL AUTHORITIES WHICH MAY HAVE JURISDICTION. 3 : THE TENANT SHALL FURNISH AND INSTALL DUCT DETECTOR(S) WITH REMOTE TEST SWITCH AND LED INDICATOR LIGHT IN EACH TENANT HVAC UNIT, IF REQUIRED BY CODE OR BY THE AUTHORITY HAVING JURISDICTION. 4 • ALL ZONES SHALL BE CLEARLY LABELED ON THE FIRE ALARM CONTROL PANEL. IF TENANT DEMISED PREMISES OCCUPIES TWO LEVELS, ZONES SHALL ALARM EACH LEVEL INDEPENDENTLY. 6 : THE TENANT SHALL USE ONLY LANDLORD DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH THE LANDLORD'S FIRE ALARM SYSTEM. FINAL TESTING OF FIRE ALARM SYSTEM PROGRAMMING AND TESTING OF THE DEVICES AND SEQUENCE OF OPERATION SHALL BE BY THE LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR AT THE TENANT'S EXPENSE. EACH TENANT'S FIRE ALARM SYSTEM SHALL BE FINAL TESTED BY THE LOCAL BUILDING AND FIRE MARSHAL AND WITNESSED BY LANDLORD'S ON-SITE ^\ REPRESENTATIVE. , ", TELEPHONE LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. ' NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT ' FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUPIMENT SHALL BE ) ; CONTAINED WITHIN THE TENANT'S SPACE. TENANT'S TELEPHONE EQUIPMENT IS NOT PERMITTED IN LANDLORD'S ) , TELEPHONE EQUIPMENT ROOM. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PERMISES UTILIZING THE LANDLORD'S SUPPLIED : CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. � U 6 TENANT �� ������Uu�~w CRITERIA U �~U����U�� K U ��~��U� �U�� & ��K K �~�[U�� SCALE: N/A PROJECT TEAM: Architect: Epoch De5Ign Group, Inc. 1laaO|*etteExec. Suite 100 St. Lov4MOaol32 TEL 314.721.1340 FAX 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: PROJECT TITLE: CIO SHEET TITLE: �U�������U ������^ ^������� POWER PLAN DRAWN BY: LBS ISSUE DATE: 11/13/07 dHN | / 1LJUO RAwDAuA.NELSON 8016 Reeder Rd. Lenexa, mmmw TEL, v1u-3u -5150 FAX, 913-322-5155 THIS DOCUMENT pTHE PROPERTY OF EPOCH DESIGN COPYRIGHTED AS DATED, AU. RIGHTS REsERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT IS NOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT IS HEREBY ADVISED THAT IT IS RELEAED FOR USE UNDER THE FOLLOWING TERMS AND CONDMONS7 THE DOCUMENT A,"BE USED ONLY w CONJUNCTION WITH THIS PROJECT, REUSE OF ANT PORTI"OF`HE DOCUMENT IN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT IS FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES NOT CONSITHITE AS-BUILT CONDITIONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDUIONs OF THE SUBJECT FROPERTY AND TO COMPLETELY COORDINATE Ail DIMENSIONS, FABRICATION METHODS, RELATED AND ==RATED SYSTEMS, ETC, WITH RESPECT TO Alt ASPUCRS OF THE WORK. EPOCH DESIGN GROUP MAKES NO wAlawavAs TO THE SUITABILITY OF THE DOCUMENT FOR THE RECIPIENT'S INTENDED USE. THE RECIPIENT SPEoFICAuAGREESmWAIVE INDEMNIFY AND DEFEND ANY AND ALL CLAMS AGAINST EPOCH DESIGN GROUP, rts CONSULTANTs, ANY OF ITS RELATE]) anirtEs, VENDORS, OR CONTRACTORS, FOR ANY LOSS INCURRED AS A RESULT OF PROPER OR IMPROPER USE OF THIS DOCUMENT., 7*/ ' - ° 44S � v n Vtll /-Ic,` "° ' 1 `"''1,-/ F4-1-gnu nr�m�c� 2 u./OWNER/CITY CmwTS0/10/0S 1 LL / OWNER COMMENTS 12/14/07 Noth, Revision Description Date PROJECT NO.: SHEET NUMBER: 07073 E2.O PANELBOARD PP BUS AMPS: 225A LOCATION: STOCK ROOM GROUND BUS: YES MAIN SIZE / TYPE: 150A MCB NEMA RATING: NEMA 1 ISOL. GROUND BUS: NP VOLTS / PHASE: 280Y/120V. 3PH, 4W AFC VALUE: VERIFY FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: VERIFY SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (vA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS P A B j C P AMPS 1 SPARE 20 1 12 0 0 0 12 1 20 SPARE 2 3 MICROWAVE 20 1 12 1,200 6 1,380 180 12 1 20 POS 4 5 REFRIGERATOR 20 1 12 800 980 180 12 1 20 POS 6 7 COMMUNICATIONS STRUCTURE 20 1 12 400 580 443 180 12 1 20 POS 8 9 COMMUNICATIONS STRUCTURE 20 1 12 400 0 760 0 360 12 1 20 POS RCPT 10 11 COMMUNICATIONS STRUCTURE 20 1 12 400 0 0 760 360 12 1 20 P05 RCPT 12 13 TTB /TC 20 1 12 400 760 1 360 12 1 20 POS RCPT 14 15 RESTROOM RCPT 20 1 12 180 0 380 1 200 12 1 20 BUZZER 16 17 INSTANTANEOUS WATER HEATERS 20 1 12 750 1 750 0 12 1 20 SPARE 18 19 MANAGER'S DESK 20 1 12 800 800 SPACE 20 0 12 1 20 SPARE 20 21 MANAGER'S DESK 20 1 12 360 560 200 12 1 20 RF ANTENNA 22 23 MANAGER'S DESK 20 1 12 360 1,200 740 - Z I 400 12 1 e 20 • Lam._ ELECTRIC WATER COOLER 26 25 SALES FLOOR RCPT 20 1 12 360 760 1,200 12 27 SALES FLOOR RCPT 20 1 12 540 540 : 1,200 -- -- - . 29 SENSORMATIC 20 1 12 800 800 0 1 20 SPARE 30 31 FIRE ALARM PANEL 20 1 12 200 200 TOTAL CONNECTED PANELBOARD (VA) TOTAL CONNECTED PANELBOARD (AMPS) TOTAL PANELBOARD DEMAND (VA) TOTAL PANELBOARD DEMAND (AMPS) 12,697 0 61 22,978 110 SPACE 32 33 SPARE 20 1 0 0 0 SPACE 34 35 DUCT SMOKE DETECTORS 20 1 12 200 200 0 SPACE 36 37 SPARE 20 1 0 6,232 6.232 - PANELBOARD 'LP' 38 39 SPARE 20 1 0 6,288 6,288 4 3 70 40 41 SPARE 20 1 0 6,465 6,465 - 42 PER PHASE SUB - TOTALS 1 9,332 1 9,908 10,695 LEGEND: TOTAL CONNECTED PANELBOARD (VA) TOTAL CONNECTED PANELBOARD (AMPS) TOTAL PANELBOARD DEMAND (VA) TOTAL PANELBOARD DEMAND (AMPS) 20.027 TS - VIA TIME SWITCH ST - SHUNT TRIP GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND EM - EMERGENCY LTG. / LOCKING TAB 72 33,928 121 EX - EXISTING TO REMAIN PANELBOARD LP BUS AMPS: 225A LOCATION: STOCK ROOM GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS / PHASE: 208Y/120V, 3PH, 4W AFC VALUE: VERIFY FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: VERIFY SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (vA) CONNECTED PER PHASE (VA) LOAD (vA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS P A B C P AMPS 1 SIGNAGE 20 1 12 1,200 1,450 250 12 1 20 EMERGENCY / EXIT / NIGHT LTG 2 3 SHOW WINDOW LTG / RCPT 20 1 12 609 6 965 356 12 1 20 STOCK ROOM /EM LTG 4 5 SHOW WINDOW LTG / RCPT 20 1 12 570 1,506 936 12 1 20 TRACK LTG 6 7 SALES AREA LTG 20 1 12 770 1.706 443 936 12 1 20 TRACK LTG 8 9 SALES AREA LTG 20 1 12 700 0 2,104 0 1,404 12 1 20 TRACK LTG 10 11 SALES AREA LTG 20 1 12 630 0 0 2,034 1,404 12 1 20 TRACK LTG 12 13 SALES AREA LTG 20 1 12 630 630 1 0 12 1 20 SPARE 14 15 SALES AREA LTG 20 1 12 819 0 819 1 0 12 1 20 SPARE 18 17 SALES AREA LTG 20 1 12 525 1 525 0 12 1 20 SPARE 18 19 SALES AREA PENDANT LTG 20 1 12 600 1,246 SPACE 20 646 12 1 20 DRESSING AREA / EM LTG 20 21 SPARE 20 1 0 1,200 1,200 12 1 20 DISPLAY LTG 22 23 SPARE 20 1 0 1,200 1,200 12 1 20 DISPLAY LTG 24 25 SPACE 0 1,200 1,200 12 1 20 DISPLAY LTG 26 27 SPACE 0 1,200 1,200 12 1 20 DISPLAY LTG 28 29 SPACE 0 1,200 1,200 12 1 20 DISPLAY LTG 30 PER PHASE SUB - TOTALS 6,232 6,288 6,465 LEGEND: TOTAL CONNECTED PANELBOARD (VA) TOTAL CONNECTED PANELBOARD (AMPS) TOTAL PANELBOARD DEMAND (VA) TOTAL PANELBOARD DEMAND (AMPS) 12,697 LC - VIA AUTOMATIC LIGHTING CONTROLS ST - SHUNT TRIP GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND EM - EMERGENCY LTG. / LOCKING TAB 61 22,978 110 PANELBOARD HP 1 I ' ) BUS AMPS: 225A LOCATION: STOCK ROOM GROUND BUS: YES MAIN SIZE / TYPE: 125A MCB NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 480Y/277V, 3PH, 4W AFC VALUE: VERIFY FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: VERIFY SECTIONS: 1 OF 1 , CKT # CIRCUIT DESCRIPTION BREAKER 4WRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (vA) WIRE SIZE BREAKER CIRCUIY,_,..,_W • -: _ _ DESCRIPTION ._CKT. # AMPS P A B 1 C P AMPS 1 PANELBOARD 'PP' VIA TRANSFORMER 'T1' - 8,932 13,932 5,000 -- VAV -1 2 3 60 3 6 9.908 16,238 6,330 10 3 30 4 5 - 10,695 15,695 5,000 - 6 7 SPACE 20 1 0 443 443 12 1 15 VAV -2 a 9 SPACE 20 1 0 0 0 1 20 SPARE 10 11 SPACE 20 1 0 0 0 1 20 SPARE 12 13 SPACE 20 1 0 0 0 1 20 SPACE 14 15 SPACE 20 1 0 0 0 1 20 SPACE 16 17 SPACE 20 1 0 0 0 1 20 SPACE 18 19 SPACE 20 1 0 01 0 1 20 SPACE 20 PER PHASE SUB - TOTALS 14,375 1 16,238 1 15,695 LEGEND: TOTAL CONNECTED PANELBOARD (VA) TOTAL CONNECTED PANELBOARD (AMPS) TOTAL PANELBOARD DEMAND (VA) TOTAL PANELBOARD DEMAND (AMPS) 46,308 TS - VIA TIME SWITCH ST - SHUNT TRIP GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND EM - EMERGENCY LTG. / LOCKING TAB OL - RE: ONE -LINE DIAGRAM 56 50,301 61 NOTE: MANUFACTURERS' NAMES ON WHICH THE SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED. SUBSTITUTION MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE OWNER'S REPRESENTATIVE. ALL WORK AND PRODUCTS SHALL MEET THE REQUIREMENTS OF THE LANDLORD. 1. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. 2. CONTRACTORS SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. FIELD VERIFY LANDLORD'S ELECTRICAL AND TELEPHONE EQUIPMENT AND DISTANCE FROM LEASED SPACE. NO CLAIMS FOR EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF EXISTING SITE CONDITIONS SHALL BE APPROVED. 3. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. ALL MATERIALS AND EQUIPMENT SHALL BE COMMERCIAL GRADE AND SHALL CARRY A U.L. LABEL. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES. 4. THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 5. ALL WORK TO BE IN ACCORDANCE WITH NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLETE ALL FORMS REQUIRED TO SECURE AND PAY FOR ALL REQUIRED PERMITS AND INSPECTION CERTIFICATES. 7. SUBMIT MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ARCHITECT FOR APPROVAL. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE ARCHITECT. 8. SCOPE OF WORK: PROVIDE ELECTRICAL SERVICE TO SPACE PER DRAWINGS AND LANDLORDS REQUIREMENTS. INSTALL NEW LIGHTING FIXTURES, PER SCHEDULE. NEW RECEPTACLES AS INDICATED. IF APPLICABLE, CIRCUITING OF RELOCATED PANEL(S). PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED. RELOCATE TRANSFORMER. PROVIDE TELEPHONE SERVICE AND TELEPHONE SYSTEM RACEWAY AND JUNCTION BOXES. ALL TELEPHONE SYSTEM WIRING AND DEVICES WITHIN TENANT SPACE FURNISHED AND INSTALLED BY OWNER. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. TESTING OF ALL ELECTRICAL EQUIPMENT. PROVISION FOR TEMPORARY CONSTRUCTION POWER. 9. CONDUIT SHALL BE STANDARD STEEL, RIGID IMC OR EMT (THIN WALL). CONDUIT SHALL BE CONCEALED IN FINISHED AREAS. EXCEPT AS OTHERWISE APPROVED BY LANDLORD'S REPRESENTATIVE. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. MINIMUM SIZES OF CONDUIT SHALL BE 3/4" EXCEPT 1/2" FOR SWITCH LEGS. EMT SHALL BE GALVANIZED OR ELECTRO- GALVANIZED. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS. USE HEAVY WALL CONDUIT OR IMC FOR UNDER SLAB INSTALLATIONS. IMC 15 PERMITTED WITH SCREW CONNECTIONS. FLEXIBLE METAL CONDUIT MAY BE USED ONLY FOR SHORT CONNECTIONS TO FIXTURES AND EQUIPMENT, AS PERMITTED BY CODE. MAXIMUM LENGTH 5' --O ". 10. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: #10 AND SMALLER -SOLID WITH SINGLE BRAID. #8 AND LARGER- STRANDED WITH AT LEAST DOUBLE BRAID. ALL WIRING TO BE 2 #12, UNLESS OTHERWISE NOTED. #14 MAY BE USED FOR CONTROL APPLICATIONS. ALL LOW VOLTAGE WIRING NOT REQUIRED TO BE IN CONDUIT SHALL BE FIRE RETARDANT PLENUM RATED. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. GENERAL WIRING SHALL HAVE (75 C) THW AND THWN OR (90' C) THHN INSULATION. ALUMINUM CONDUCTORS ARE NOT PERMITTED. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND T &B "LOCK- -TITE" FOR #6 AND LARGER. WIRES SHALL BE COLOR CODED AND FOLLOWED THROUGHOUT FOR FEEDERS AND BRANCH CIRCUITS AND USED AS A BASIS FOR BALANCING LOADS: USE 10 AWG (MINIMUM) CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 FEET. USE 10 AWG (MINIMUM) CONDUCTORS FOR 20 AMPERE, 277 VOLT BRANCH CIRCUITS LONGER THAN 150 FEET. 120/208 Y VOLTS PHASE COLOR A B C NEUTRAL GROUND 11. BOXES AND FITTINGS: 20 BLACK RED BLUE WHITE GREEN SHEET METAL BOXES: NEMA OS 1. 277/480 Y VOLTS PHASE COLOR A YELLOW B BROWN C ORANGE NEUTRAL WHITE W/TRACER OR GRAY GROUND GREEN BOXES AND FITTINGS SHALL BE NEW, TOP QUALITY AND LOCATED WHERE REQUIRED TO INSTALL THE CONDUCTORS IN COMPLIANCE WITH THE PREVAILING CODES. APPROVED MANUFACTURES ARE: STEEL CITY, RACO OR APPLETON. CAST METAL BOXES: NEMA FB 1, TYPE FS OR FD, CAST FERROALLOY BOX WITH GASKETED COVER. BOXES IN FIRE -RATED WALLS SHALL HAVE A FIRE RATING EQUAL TO OR GREATER THAN THE RATING OF THE WALL. 12. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE SPEC. GRADE, 20A, 120/277V, WITH SCREW TERMINALS, EQUAL TO HUBBELL #HBL1221. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR OR LEVITON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, COMMERCIAL GRADE, 20A, 125V EQUAL TO HUBBELL #5362. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE, DUPLEX RECEPTACLES, FEED- THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, 20A, 120V, 60 HZ; WITH SOLID -STATE GROUND FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND -FAULT TRIP LEVEL EQUAL TO HUBBELL #GF5362. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR. OR LEVITON. WEATHERPROOF RECEPTACLE COVER SHALL BE HUBBELL #WP826MP. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. DEDICATED DUPLEX RECEPTACLES SHALL BE RED, 2 -POLE, 3 -WIRE 20A, 125V, STRAIGHT BLADE DEVICE WITH DEDICATED GROUND CONNECTION, EQUAL TO HUBBELL #5362 -R. APPROVED MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. WIRING DEVICE ACCESSORIES INCLUDING ALL WALL PLATES SHALL BE PROVIDED AT EACH DEVICE. WALL PLATES SHALL BE SAME COLOR AS DEVICE AND MANUFACTURED AS A 4T,J,2 i�rn ICAL SPECIFICATIONS COMPANION TO THE DEVICE. ALL WIRING DEVICES AND COVERPLATES SHALL BE WHITE UNLESS NOTED OTHERWISE. MOUNTING HEIGHTS OF DEVICES SHALL BE TO THE FOLLOWING CENTERLINES, UNLESS NOTED OTHERWISE: TOGGLE SWITCHES RECEPTACLES TELEPHONE OUTLETS DISCONNECT SWITCHES (TOP) PANELBOARDS (TOP) 5' -6" 6' -O 13. GROUNDING SYSTEM: THIS CONTRACTOR SHALL PROVIDE, INSTALL, AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE, AND NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFIRM WITH SECTION 250 OF THE NEC. PROVIDE CONDUIT TO PROTECT GROUND WIRE FROM DAMAGE TO AN AREA 6' -0" ABOVE FLOOR. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON- METALLIC CONDUIT. A SEPARATE DEDICATED, INSULATED GROUND SYSTEM SHALL BE INSTALLED FOR ELECTRONIC CASH REGISTERS. PANELBOARDS: PANELBOARDS SHALL BE DEAD FRONT AND CONSIST OF CABINETS, INTERIORS, BUS, MAIN AND BRANCH CIRCUIT PROTECTIVE DEVICES, MAIN LUGS, AND ALL NECESSARY EQUIPMENT FOR A COMPLETE PANELBOARD. DETAILED CHARACTERISTICS SUCH AS NUMBER OF BRANCHES, FRAME OR AMPERE RATING, TRIP, BUS SIZE, TYPE MOUNTING OR VOLTAGE RATINGS, SHALL BE AS SHOWN ON THE DRAWINGS. CABINET SHALL BE FABRICATED OF CODE GAUGE, HOT GALVANIZED STEEL WITH ADEQUATE GUTTERS. JOINTS SHALL BE WELDED AND REINFORCED WHERE REQUIRED. THE OUTSIDE OF SURFACE MOUNTED CABINETS SHALL BE FINISHED WITH ONE COAT OF ZINC CHROMATE PRIMER AND AT LEAST ONE COAT OF GRAY ENAMEL. LOAD CENTER TYPE PANELBOARDS ARE NOT ACCEPTABLE. TRIM AND PANELBOARD FRONT SHALL BE MADE OF COLD- ROLLED STEEL OF CODE GAUGE STEEL. TRIM SHALL HAVE DOORS WITH CONCEALED HINGES AND HAVE A FLUSH TYPE COMBINATION LOCK AND CATCH OR A MULTIPLE POINT CONTACT CATCH. EACH LOCK SHALL BE PROVIDED WITH TWO KEYS. ALL PANELBOARDS SHALL BE KEYED ALIKE. FURNISH AND INSTALL A TYPED INDEX IDENTIFYING THE PANELBOARD AND INDICATING THE CIRCUIT NUMBER WITH THE DESCRIPTION OR FUNCTION OF THE ASSOCIATED BRANCH CIRCUIT. INDEX SHALL BE MOUNTED UNDER A CLEAR GLASS OR PLASTIC PROTECTIVE COVER. TRIM SHALL BE CLEANED, AND GIVEN A PRIME COAT OF PAINT AND AT LEAST ONE FINISHED COAT OF GRAY ENAMEL. ALL LUGS SHALL BE OF THE SOLDERLESS TYPE. ALL PANELBOARDS SHALL INCLUDE EQUIPMENT GROUND BUS. ALL PANELBOARDS SHALL HAVE ENGRAVED NAMEPLATES IDENTIFYING PANELBOARDS AS INDICATED BY OWNER. ALL PANELBOARD SWITCHES AND CIRCUIT BREAKERS SHALL BE LABELED AS DIRECTED BY OWNER. PROVIDE EQUIPMENT AND ISOLATED GROUND BUSES, AS CALLED OUT IN THE PANELBOARD SCHEDULE. 277/480 VOLT PANELS SHALL BE EQUAL TO SQUARE D TYPE NF WITH TYPE EDB (25000 AIC) BOLT -ON CIRCUIT BREAKERS. 120/208 VOLT PANELS SHALL BE EQUAL TO SQUARE D TYPE NOM WITH TYPE QOB (22000 AIC) BOLT -ON CIRCUIT BREAKERS. THE FOLLOWING ARE APPROVED MANUFACTURERS: GENERAL ELECTRIC, SIEMENS, AND SQUARE D. 14. WORK IN ELECTRICAL PANEL SHALL INCLUDE: CHECK AND TIGHTEN ALL CONNECTIONS AND WIRING. VERIFY OPERATION OF ALL BREAKERS. CIRCUIT BREAKERS SHALL BE QUICK -MAKE, QUICK - BREAK, TRIP INDICATING TYPE AND AMBIENT COMPENSATING. CIRCUIT BREAKERS SHALL BE BOLT ON TYPE, MINIMUM INTERRUPTING SHALL BE AS NOTED ON PANEL SCHEDULE. BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. BREAKERS SERVING HVAC EQUIPMENT SHALL BE HACR RATED. PROVIDE "LOCK -ON" DEVICE AT BREAKERS SERVING CASH REGISTER, NIGHT LIGHT /EMERGENCY, FIRE ALARM EQUIPMENT AND TIME SWITCH CIRCUITS, AS INDICATED ON THE PANEL SCHEDULE. PROVIDE PANEL DIRECTORY, TYPED AND INSTALLED BEHIND CLEAR PLASTIC COVER ON INSIDE OF THE DOOR. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES TO WITHIN 10% PER NEC. 15. SAFETY AND DISCONNECT SWITCHES: PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON - FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY CODE. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED. EQUAL TO SQUARE 16. D TYPE H, AS MANUFACTURED BY SQUARE 0, GENERAL ELECTRIC OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. 17. FUSES: CARTRIDGE FUSES SHALL BE ONE TIME BUSSMANN "LOW- PEAK" SIZED ACCORDING TO THE LOAD OR AS INDICATED ON THE DRAWINGS. PROVIDE FUSES IN ALL SWITCHES REQUIRING THEM. IN ADDITION, FURNISH TO THE OWNER ONE SET OF EACH SIZE AND TYPE FUSE ON THE JOB. 18. DRY TYPE TRANSFORMERS: TRANSFORMERS SHALL BE OF KVA RATING AS NOTED ON THE DRAWINGS, 2 WINDING, DRY TYPE, 3 PHASE, WITH SIX 2 -1/2% TAPS, 2 ABOVE AND 4 BELOW NORMAL PRIMARY VOLTAGE. TRANSFORMER SHALL BE NEMA TYPE 1, QUIET TYPE WITH CORE AND COILS ISOLATED FROM THE CASE BY VIBRATION DAMPERS. TRANSFORMERS SHALL BE EQUAL TO SQUARE D TYPE WATCHDOG (TP -1), AS MANUFACTURED BY SQUARE -D, GENERAL ELECTRIC, OR EQUAL. 19. SEISMIC RESTRAINS ON ELECTRICAL EQUIPMENT: ALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED WITH SEISMIC RESTRAINING SERVICES AS REQUIRED BY LOCAL BUILDING CODES. CONTRACTOR SHALL HAVE LOCAL BUILDING OFFICE REVIEW EACH PIECE OF EQUIPMENT WHEN INSTALLED AND THE CONTRACTOR SHALL INSTALL ALL REQUIRED TIE DOWN, ANCHORS, STRAPS OR OTHER DEVICES REQUIRED. 20. TELEPHONE SYSTEM: MAKE ARRANGEMENTS WITH THE LOCAL UTILITY FOR INSTALLATION OF TELEPHONE SERVICE. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANTS PREMISES SHALL BE PROVIDED AS REQUIRED BY CODE OR AS INDICATED ON THE DRAWINGS. TELEPHONE ROUGH -IN OUTLET BOXES SHALL BE 2 -1/8" MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. 21. THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY THE COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND FOR THE REMOVAL OF SAME, CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. 22. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED, ANY CUTTING SHALL HAVE PRIOR APPROVAL BY THE LANDLORD. CONTRACTOR IS RESPONSIBLE TO TAKE WHATEVER MEASURES ARE NECESSARY INCLUDING BUT NOT LIMITED TO THOSE MEASURES PRESCRIBED BY THE LANDLORD IN THE EXERCISE OF ITS REASONABLE JUDGEMENT TO ASSURE THAT COREBORING WILL NOT DAMAGE LANDLORD'S STRUCTURE, CONDUITS, ETC. OR THE WORK OF OTHER TENANT'S BELOW. THE COST OF SUCH TESTS OR REPAIR OF ANY DAMAGE WILL BE BORNE BY THIS CONTRACTOR. ALL SLEEVED, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION WITH SEALER EQUAL TO OR EXCEEDING FIRE RATING OF FLOOR OR WALL. 23. ALL ELECTRICAL WORK SHALL BE INSTALLED 50 AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING. MAINTAINING AND REPAIR. 28. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL E CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT A LL GO S LLB GE LED E E OS5 BLE E OSED CO DUIT SH LL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCK LINES. 24. LIGHTING FIXTURES: THE CONTRACTOR SHALL INSTALL A NEW LIGHTING FIXTURE OF THE TYPE SPECIFIED FOR EACH LIGHTING OUTLET SHOWN WITH COMPLETE LAMPS OR TUBES. ALL FIXTURES SHALL BE HUNG AND MOUNTED IN PLACE, PROPERLY WIRED, TESTED AND LEFT READY FOR OPERATION. NOTE! THIS CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, FOR FIXTURE SCHEDULE AND SHALL INSTALL FIXTURES AS DIMENSIONED ON THAT PLAN. THE OWNER SELECTS AND PROVIDES ALL LIGHTING FIXTURES, COMPLETE WITH ACCESSORIES AND LAMPS. REFER TO THE LIGHT FIXTURE SCHEDULE ON ELECTRICAL DRAWINGS. FIXTURES PROVIDED BY OWNER SHALL BE SHIPPED TO THE SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. THE CONTRACTOR SHALL SURVEY THE SHIPMENT TO VERIFY FIXTURE QUANTITIES AND DAMAGES. IN THE EVENT THAT SHIPMENT IS INCOMPLETE OR DAMAGED, THIS CONTRACTOR SHALL INFORM OWNER. AFTER THE SHIPMENT IS VERIFIED AND ACCEPTED, CONTRACTOR SHALL MOVE FIXTURE TO AN AREA OF SAFETY FOR STORAGE UNTIL THEY MAY BE INSTALLED. HE ASSUMES RESPONSIBILITY FOR THE FIXTURES UNTIL THE PROJECT IS TURNED OVER TO THE OWNER. 25. PAINTING OF ELECTRICAL CONDUITS, ETC,. IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. 26. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES, AND UPON COMPLETION SHALL TURN OVER TO THE TENANT A RECORD SET OF PRINTS SHOWING THESE CHANGES. 27. AT THE COMPLETION OF JOB, CONTRACTOR SHALL REPLACE ANY LAMPS THAT HAVE BURNED OUT, NEW AND EXISTING, CLEAN ALL FIXTURES, TOUCH UP ANY SCRATCHES AND REPLACE ANY FIXTURES THAT HAVE BEEN DAMAGED. GUARANTEE: MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY HIM. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE -OUT. 29. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. 30. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. SYMBOL 0 2$ cb GFCI 1S LV +12" oD * DESCRIPTION CONDUIT UP +2" UNLESS NOTED CONDUIT DOWN CONDUIT HOMERUN UNDERGROUND CONDUIT HOMERUN CONDUIT - AS SHOWN INDICATES (1) HOT /SWITCH LEG, (1) NEUTRAL, (1) GROUND UNDERGROUND CONDUIT - AS SHOWN INDICATES (1) HOT /SWITCH LEG, (1) NEUTRAL, (1) GROUND THREE PHASE CIRCUIT - TICK MARK INDICATES (3) CONDUCTORS, (1) GROUND SINGLE PHASE CIRCUIT - TICK MARK INDICATES (2) CONDUCTORS, (1) GROUND NOTE: 3 -WAY AND 4 -WAY SWITCHING REQUIRES ADDITIONAL CONDUCTORS FOR PROPER OPERATION. PROVIDE AS REQUIRED FOR A COMPLETE WORKING LIGHTING CONTROL SYSTEM. PROVIDE UN- SWITCHED HOT TO ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS. SINGLE POLE WALL SWITCH WALL SWITCH - DESIGNATIONS AS FOLLOWS: 2 =2 POLE 4 =4 -WAY 3 =3 -WAY P =PILOT LIGHT M =MOTOR RATED SWITCH H= LIGHTED HANDLE DM= DIMMER MS =MOTION SENSOR SWITCH (HUBBELL #ATP1277W) SIMPLEX RECEPTACLE - NEMA 5 -20R UNLESS NOTED OTHERWISE DUPLEX RECEPTACLE -- NEMA 5 -20R UNLESS NOTED OTHERWISE DOUBLE - DUPLEX RECEPTACLE -- NEMA 5 -20R UNLESS NOTED OTHERWISE RECEPTACLE DESIGNATIONS AS FOLLOWS: GFCI= GROUND FAULT INTERRUPTER WP= WEATHERPROOF S= SWITCHED E= EMERGENCY POWER IG= ISOLATED GROUND AC =ABOVE COUNTER HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED ON PLANS, FLOOR MOUNTED DUPLEX RECEPTACLE CEILING MOUNTED DUPLEX RECEPTACLE QUAD RECEPTACLE JUNCTION BOX LOW VOLTAGE BELL LOW VOLTAGE CHIME SUB-WOOFER SPEAKERS EXHAUST FAN DATA OUTLET TELEPHONE OUTLET TIMESWITCH ELECTRICAL SYMBOLS SCALE: N/A LOW VOLTAGE 12" ABOVE FLOOR LINE OF AREA WHERE SHOWN ELECTRICAL PANELBOARD DUCT SMOKE DETECTOR /) NON-FUSED DISCONNECT SWITCH 60/3 = 60 AMP SWITCH, 3 POLE FUSED DISCONNECT SWITCH 60/3/40 = 60 AMP SWITCH, 3 POLE, 40 AMP FUSE u L� 3 4 5 LC1 LC1 LC1 LC2 LC2 LC2 LC2 LC3 LC3 LC2 17 LANDLORD'S MAIN DISTRIBUTION AND MASTER METERING EQUIPMENT LOCATED IN LANDLORD'S ELECTRICAL ROOM. VERIFY LOCATION ON SITE. LANDLORD PROVIDED MAIN CIRCUIT BREAKER. LANDLORD PROVIDED MASTER METERING EQUIPMENT IN LANDLORD'S ELECTRICAL ROOM. THE LANDLORD - OWNED NETWORK METERING SYSTEM WILL METER TENANT POWER CONSUMPTION. LANDLORD SHALL PROVIDE (4) #3/0 AND (1) #6 GROUND IN 2" CONDUIT FROM LANDLORD'S DISTRIBUTION EQUIPMENT TO LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE. LANDLORD PROVIDED FUSED DISCONNECT SWITCH. IF NEEDED TO ACCOMMODATE TENANT CONSTRUCTION, THE TENANT SHALL RELOCATE THE LANDLORD PROVIDED DISCONNECT SWITCH AND ASSOCIATED FEEDERS. PROVIDE (4) #3/0 AND (1) #6 GROUND IN 2" CONDUIT FROM FUSED DISCONNECT SWITCH TO PANELBOARD 'HP'. PROVIDE 225 AMP PANELBOARD 'HP' WITH 125 AMP MAIN CIRCUIT BREAKER. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. PROVIDE (3) #6 FEEDERS IN 1" CONDUIT FROM PANELBOARD 'HP' TO TRANSFORMER 'T1'. PROVIDE 45 KVA DRY TYPE TRANSFORMER WITH 480V, 3 PHASE DELTA PRIMARY TO 120/208V, 3 PHASE WYE SECONDARY. TRANSFORMER SHALL BE FLOOR MOUNTED. PROVIDE #6 GROUND IN CONDUIT FROM TRANSFORMER TO BUILDING STEEL. PROVIDE (4) #1/0, (1) #6 GROUND, AND (1) #6 ISOLATED GROUND IN 2" CONDUIT FROM TRANSFORMER 'T1' TO PANELBOARD 'PP'. PROVIDE 225 AMP PANELBOARD 'PP' WITH 150 AMP MAIN CIRCUIT BREAKER. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. PROVIDE 225 AMP PANELBOARD 'LP' WITH MAIN LUGS ONLY. SEE PANELBOARD SCHEDULES FOR MORE INFORMATION. POWER RISER DIAGRAM SCALE: N/A PANELBOARD SCHEDULES SCALE: N/A 13 FURNISH AND INSTALL TORK DZS400A (7 -DAY PROGRAMMABLE) TIME CLOCK TO CONTROL LIGHTING CONTACTORS. SET TIME AS DIRECTED BY LANDLORD AND OWNER, SHOW WINDOW LIGHTING AND SIGNAGE SHALL BE SET TO MALL'S OPERATING HOURS. [14 FURNISH AND INSTALL (3) CO 917LIG '^yµ ) LIGHTING CONTACTORS, POLES AS REQUIRED, IN STANDARD NEMA 1 ENCLOSURE. MOUNT ADJACENT TO PANEL LP. 7 HP 6 8 PP 11 10 NOTE: THIS RISER DIAGRAM REPRESENTS (AS ACCURATELY AS POSSIBLE) THE EXISTING ELECTRICAL DISTRIBUTION SYSTEM. FIELD VERIFY ALL SIZES OF EQUIPMENT, CONDUCTORS, FUSES, ETC. SIZES SHOWN ON THIS DRAWING SHALL BE CONSIDERED A MINIMUM. ANY EXISTING EQUIPMENT CONDUCTORS, FUSES, ETC. WHICH DO NOT MEET MINIMUM SHALL BE REPLACED TO MEET MINIMUM. FUSES FOR HVAC EQUIPMENT SHALL BE PER UNIT NAMEPLATE DATA FUSE AMPACITYSHALL NOT EXCEED CONDUCTOR AMPACITY, . .• , , ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE, ON BACK WALL, FOR TEMPORARY ELECTRICAL FOR i ;' CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE. . ,. P, Eve IG,LCK IG,LCK I G,LCK EM EM,LC3 LC2 LC2 LC2 LC2 EM,LC3 LC2 LC2 LC2 LC2 LC2 0 :1 , 4 m11 NO.® ,4 U ra.4 PROJECT TEAM: Architect: Epoch Design Group, Inc. 1 155 Olivette Exec. Pkwy. Suite 100 St. Louts, MO 63132 TEL 314.721.1340 FAX: 314.72 L0344 M. E. P. & F.P. ,Engineer: COPYRIGHT DISCLAIMER: THIS DOCUMENT IS THE PROPERTY OP EPOCH DESIGN GROUP, COPYRIGHTED A5 DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT IS NOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT IS HEREBY ADMSED THAT T IS RELEASED FOR USE UNDER THE FOLLOWING TERMS AND CONDMONS, THE DOCUMENT IS TO BE USED ONLY IN CONJUNCTION WITH THIS PROJECT. REUSE OF ANY PORTION OF THE DOCUMENT TN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT IS FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES NOT CONSTITUTE AS -BURT CONDITIONS. THE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDITIONS OP THE SUBJECT PROPERTY AND TO COMPLETELY COORDINATE ALL DIMENSIONS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF THE WORK. EPOCH DESIGN GROUP MAKES NO WARRANTY AS TO THE SUITABILITY OF THE DO WMENT FOR THE RECIPIENT'S INTENDED USE. THE RECIPIENT SPECIFICALLY AGREES TO WAIVE AND TO INDEMNIFY AND DEFEND ANY AND AL CLAMS AGAINST EPOCH DESIGN GROUP, ITT CONSULTANTS, ANY OF ITS RELATED ENTITIES, VENDORS, OR CONTRACTORS, FOR ANY LOSS INCURRED AS A RESULT OF PROPER OR IMPROPER USE OF THIS DOCUMENT. THE RECIPIENT AGREES TO RETURN Ok DESTROY THIS DOCUMENT UPON COMPLETION OR TERMINATION OF WORK PERFORMED N N ON WITH THIS PROJECT. .�- `H: SHEET TITLE: PROJECT NO.: 07073 DRAWN BY: LBS ISSUE DATE: 11/13/07 RECEIVED CST r OF TU vviiA JAN 1 1 ZOO ••,r Ir 6w141d /44 4.6 lr / 14TH RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL 913-322-5150 FAX, 913- 322 -5155 LU V 0 2 L.L. /OWNER /CITY CMNTS 01 /10/08 1 L.L. / OWNER COMMENTS 12/14/07 Revision Description Date ELECTRICAL SPECIFICATIONS, PANELS, AND RISER SHEET NUMBER: E4.0