Loading...
HomeMy WebLinkAboutPermit PG07-340 - WESTFIELD SOUTHCENTER MALL - DELIASDELTAS 2606 SOUTHCENTER MALL PGO 7-340 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: BOND PLUMBING Address: 1630 215 ST SW , LYNNWOOD WA Contractor License No: BONDP* *098K1 Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2606 SOUTHCENTER MALL TUKW DELIAS 2606 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA TIM SCHENK 1120E 80 ST, STE 211 , BLOOMINGTON MN DESCRIPTION OF WORK: PLUMBING FOR TI: INSTALLATION OF (2) NEW RESTROOMS. WORK TO INCLUDE FIXTURES AND PIPING. $4,000.00 $207.50 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 800 541 -0821 Phone: 425 672 -8281 Expiration Date: 04/23/2009 PGO7 -340 05/30/2008 11/26/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) O Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 O Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 1 grease interceptors 0 O Repair or alteration of water piping and/or water 2 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 1 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 PG07 -340 Printed: 05-30 -2008 Print Name: Permit Center Authorized Signature: / J111 1kAc I hereby certify that I have read and doc: UPC -10/06 City orTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3xa this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied,wijh, whether specified herein or not. The granting of this permit does not presume to give uthority to violate or cancel the provisions of any other state or local laws regulating construction or the performanc ,of -wor) I arg au t3 zed to sign and obtain this plumbing /gas piping permit. '0% Signature: Date: Permit Number: PGO7 -340 Issue Date: 05/30/2008 Permit Expires On: 11/26/2008 Date: tc1 l� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG07 -340 Printed: 05-30 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: DELTAS 2606 SOUTECENTER MALL TUICW 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 3: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 5: ** *PLUMBING AND GAS PIPING * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 6: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 7: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 8: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 9: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. PG07 -340 ISSUED 12/18/2007 05/30/2008 10: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 11: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 12: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 13: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 14: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 15: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to doc: Cond -10/06 PG07 -340 Printed: 05-30 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 16: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 * *continued on next page ** PG07 -340 Printed: 05-30 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond - 10/06 Date: 5 -30- ‹ PG07 -340 Printed: 05-30 -2008 V CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup:/lwww.ci.tulcwila.wa.us SITE LOCATION Site Address. $OUfl4CFJ ni Z. " Tenant Name: DG IA AS Property Owners Name: HaSTFtELO CORPCKLATI Otn4 . !etc. . Mailing Address: I (60 WI l...s. I(tac !IWO Sti ire 11(10 , Las AKGEUES, CA ROO City State CONTACT PERSON - who do we contact when your permit is ready to be issued Name: TIM SCAAErt44 N I Et-oER -BONES Mailing Address: (110 E • 2,O st'•. SV ire 21t a E -Mail Addressff eld ee jc ne t•C0o- GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 1 . Mailing Address: Building Permit 1 4 ' Mechanical Permit No.-- Plumbing/Gas Permit No. Public Works Permit No. Project No. Vol l (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** €uoorn Ir C.rG-J, (rlr! SS 4713 State King Co Assessor's Tax No.: i — 0010 Suite Number: 210 d Floor: Z HO New Tenant: El Yes El ..No Day Telephone: 1 • 1500 • Sy I City State Fax Number: qSZ • SSA •44I9 Zip Zip Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT_OF RECORD -All plans must be wet stamped by Architect of Record Company Name: StMt€fl S (4OC4C. AeLL1a (fY U^5 Mailing Address: 6110 5. S1rtg■MV( IeoO I4ESC1:"YZ(IC . 014 L-13O11 t 4 + City State Zip Contact Person: REG eccA Oriel Day Telephone: 614 • VS• qSs', E -Mail Address: rOrte /e..5hYtexr1S('10CIk.C.On... Fax Number: 6(4 •5r 45"• J SAS ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record Company Name: SA ° HOC{ ertG1"1 a A. t 1. (C 43Oa Cit Day Telephone: Gtr(• +�i {r • 4 rS Fax Number: 61( • smr • r Contact Person: 1ZEC CC f itAr HI:YI. Q:Upplications\Fonns- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh E -Mail Address: r f 'c► ° ' e. slArew+d%la Ck • CO"-- State Zip Page 1 of 6 BUILDING PERMIT INFORMION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ '240,000. e. " Existing Building Valuation: $ Scope of Work (please provide detailed information): aalt.0 O GI (l rA S'�e'14/lr'Ir' CPs CE s . c rt4 . WlA(L 1S` Floor 2" Floor 3`� Floor ............................. Floors thru Basement Accessory Structure* Provide All Building Areas in Square Footage Belo Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck !. Uncovered Deck PLANNING DIVIS N: ay Interior Remodel Addition to Existing Structure New !' Type of Construction per IBC 11- 13 Type of Occupancy per IBC Will there be ne rack storage? la Yes Single family buildi .: footprint (area of the foundation of all structures, plus any decks over 1. 'nches and overhangs greater than 18 inches) *For an Accesso dwelling, provide the following: Lot Ar- (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Prov e documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of ' . king Stalls Provided: Standard: Will there be a change in use? ❑ Yes Q: Applications\Fonns- Application On LineV3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑.. No If yes, a separate permit and plan No Compact: mittal will be required. Handicap: If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ( No If "yes ; attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty'' Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) 1 Wash fountain ' Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 2. Sinks I Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Z Water Closet Z Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent . I Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS _PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): PareVIUJi $1 On/ O 1' TKO NEW Rampart/ / . A (tEmi 1. TV.., r ,r SPALE . NortA4 ry sr rcwo x■vrter AP, •-. Building Use (per Intl Building Code): in Occupancy (per Intl Building Code): I ad Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:Wpplications\Fonns- Applications On Line\3 -2006 - Permit Appliatioadoc Revised: 9 -2006 bit City State Zip Sewer: Page 5 of 6 PERMIT APPLICATION NOTES Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU H RIZED AGENT: Signature: Print Name: -rI M SC larik - Day Telephone: 1.800• Szl 1 • a8 Mailing Address: P0 E. €0 SV%I'C 21% Q1.WmItOr W( 1 1 .i Ss'i Cit State Date Application Expires: orAsly$ I Date Application Accepted: 1-lia ld1- Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9-2006 bh Date: 2f / Zip staff Initials: Page 6 of 6 i Receipt No.: R08 -01861 Payee: BOND PLUMBING ACCOUNT ITEM LIST: Description PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 7998 168.00 RECEIPT Parcel No.: 6364200010 Permit Number: PG07 -340 Address: 2606 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/18/2007 Applicant: DELTAS Issue Date: Initials: JEM Payment Date: 05/30/2008 10:12 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Account Code Current Pmts 000/322.100 168.00 Total: $168.00 Payment Amount: $ 168.00 3028 05/30 9711 TOTAL 168.00 doc: Receipt -06 Printed: 05-30 -2008 RECEIPT NO: R07 -02796 Initials: JEm User ID: 1165 Payee: ELDER -JONES SET ID: 5000000921 SET TRANSACTIONS: Set Member Amount D07 -466 EL07 -790 M07 -280 PG07 -340 TOTAL: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us 1,251.89 94.30 66.36 39.50 1,452.05 TRANSACTION LIST: Type Method Description Payment ACCOUNT ITEM LIST: Description Check '50447 ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Account Code 000.345.832.00.0 000/345.830 TOTAL: Payment Date: 12/18/2007 Total Payment: 1,452.05 SET NAME: Tmp set/Initialized Activities Amount 1,452.05 1,452.05 Current Pmts 94.30 1,357.75 1,452.05 6258 12/19 9710 TOTAL 1452.05 Project: Dei7a_ir Type of Inspection: 742:1A--/ Address: 1 Date Called: Special Instructions: Date Wanted: � / l � ! o 9 c o ., Requester: Phone No: (Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 13 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Goerec/, v4 wit!/ /t j' I P El $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: (Date: INSPECTION RECORD Retain a copy with permit Roo U PERMIT NO. V— (206)431-36 INSPECTION NO. CITY OF TUK BUILDING DIVISION 6300 Soutenter Type o I"p t∎l 4 t..._ AA Proje t l A S Ad dres : 11 A I Special Instructions: Date Called: Date Wanted: a. Requester: Phone No: 90 - 75Z / 0 Approved per applicable codes. Corrections required prior to approval. 0 COMMENTS: tk Fly c as i4' T .- + ; I F ehe an G- 24-01( Ce9rtiet 74 t,Jii n(i -d r.,er Date: 7` 1 Inspector: El $60.00 REI paid at 1 6300 Southc0 REQUIRED. nter BL d., Suitte 100. Call to schedule rein pection. COMMENTS: Typ�1; Inspection: k- 1 t\l4 (- t LAvt 1.7 ll f 1 + N . . . 1 -- ` �(- Date Called: 6) P4.0 ,J i APP 'd J \ Date Wanted: O - z _ -0 a. r Requester: 1 -. ( Oa.I- i r., i, f I< Imo . i I , . (..) a 0 1 - , e C) a , 0 , k t O s o I P.-- ' o' . Proj QF Lt A-S Typ�1; Inspection: k- 1 t\l4 (- t LAvt 1.7 Address: ` 2o(, nnPi < Date Called: Special Instructions: Date Wanted: O - z _ -0 a. r Requester: Phone No: -7-06, 76 (..) i 7-3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 INSPECTION RECORD Retain a copy with permit Approved per applicable codes. ❑ Corrections required prior to approval. (Inspector: ic io...ta. Date: 0 4 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Pro - � Typ f Inspe i i eR-j hon: ' / /x/P �' Address: /my / 6.0‘, l Date Called Special Instructions: Date Wanted: — /D 'VP a.m. cam Requester: Phone No: 44-7/ -2760 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f r-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 M Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 0 El $60.0 T REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: IDate: Project: Type of Inspection Address: 0( Date Called: Special Instructions: Date Wanted / / / / � m,„ p.m. Requester: Phone No: � 7/ ? i/ ,.276 /, P607-3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION , 630 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: MI/ 46f 1 - -s tinier s /a I InsPector> ,,L� icy (Date: 6 6/oe El $60. INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: 05 -08 -2008 TIM SCHENK 1120E 80 ST,STE211 BLOOMINGTON MN 55240 City of Tukwila RE: Permit Application No. PG07 -340 2606 SOUTHCENTER MALL TUKW Dear Permit Applicant: Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current permit application files, it appears that your permit application applied for on 12/18/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 06/15/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 06/15/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: fer Marshall 't Technician Permit File No. PG07 -340 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: PG07 - 340 DATE: 12 -18 -07 PROJECT NAME: DELIAS SITE ADDRESS: 2606 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: ��. ,� 1 i 2 341 Building - Division P blic W orks D RMINATION OF COMPLETENESS: (Tues., Thurs.) Complete r --- 0 / 0 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route g Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 011000 jiwaad PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ Approved with Conditions I ' Planning Division ❑ Permit Coordinator n C DUE DATE: 12-20-07 DATE: DUE DATE: 01-17-08 Not Approved (attach comments) n DATE: Not Applicable C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License BONDP * *098K1 Licensee Name BOND PLUMBING Licensee Type CONSTRUCTION CONTRACTOR UBI 601319698 Ind. Ins. Account Id #3 Business Type INDIVIDUAL Address 1 1630 215TH ST SW Address 2 City LYNNWOOD County SNOHOMISH State WA Zip 98036 Phone 4256728281 Status ACTIVE Specialty 1 PLUMBING Specialty 2 UNUSED Effective Date 5/21/1991 Expiration Date 4/23/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BOND, CURTIS OWNER 01/01/1980 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #3 RLI INS CO SRS1008453 04/21/2002 Until Cancelled $6,000.00 04/22/2002 CUMBERLAND CASULTY & Until Look Up a Contractor, Electric` -n or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= BONDP * *098K1 05/30/2008 ( 7) 3/4" ( 9 ) (TYP) WH -I `1 I � � 1 13/4" 1/2" hr 1 1 1 1/2" PROVIDE DIELECTRIC WATER FITTINGS/ UNIONS AT TANK. .3/4" L EI 1/2" 3/4" ( 5 ) ( 6 ) C7) WATER RISER SCALE: NONE ENC -1 -O ( 6 ) WHA PLUMBING FIXTURE SCHEDULE GENERAL CONTRACTOR SHALL INSTALL THE FOLLOWING FIXTURES AS FURNISHED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ACCESSORIES REQUIRED TO ROUGH-IN FIXTURES. MARK WC -1 LAV - EWC -1 MS - 1 NH -1 GC SHALL FURNISI -1 AND INSTALL THE FOLLOWING FIXTURES COMPLETE WITH ALL ACCESSORIES REQUIRED FOR ROUGH -IN. MARK F - WHA TP NCO FCO City of Tukwila BUILDING DIVISION FIXTURE WATER CLOSET LAVATORY ELECTRIC WATER COOLER MOP SINK WATER HEATER FIXTURE FLOOR DRAIN WATER HAMMER ARRESTER TRAP PRIMER WALL CLEAN OUT FILE COPY Permit No. Plan review approval Is subject to erg and omissions. Approval of construction documeds � the violation of any adopted code or of approved Field Copy an is acknowledged: By Date :. REVISIONS h a n g e s No c sshallbemadetothescope of work without prior approval of Tukwila R,ailding Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees r �• 1 -1/2" ( 6 ) MANUFACTURER AND MODEL NO. AMERICAN STANDARD #2002.014 (SEE RESPON5 181 LITY SCHEDULE ON MO2.0) AMERICAN STANDARD #0124.024 (SEE RESPONSIBILITY SCHEDULE ON MO2.0) HALSEY - TAYLOR #HTVSBL -Q (SEE RESPONSIBILITY SCHEDULE ON MO2.0) MUSTEE #63M (SEE RESPONSIBILITY SCHEDULE ON MO2.0) A .Q. SMITH #DEL -10 (SEE RESPONSIBILITY SCI- IEDULE ON MO2.0) MANUFACTURER AND MODEL NO. JOSAM #30003- 5A -50 -Y SIOUX CHIEF #653 -A SERIES. PRECISION #P2 -500 ZURN #ZAN13-- 1460 -9 FLOOR ZURN #Z- 1400 -4D-2 CLEAN OUT 3" 2 11 1/2" FROM (TYP.) WCO AN WC -1 2" 4" CW 1/2" 1 /2 1/2" 1/2" 1/2" CW 1/2" 3/4" 1 -1/2" 1-I'N I /2" 1/2" 1/2" HN 3/4" APfr RI VED LAV -1 4 " WASTE 4" 1 -1/2" 1 -1/2" 3 WASTE 3" I BL SEPARATE PERMIT REQUIRED FOR: r M�Mechanic a i I Electrical 0 0 Plumbing Gas Piping City of Tukwila i /I_I II`dG DIVISION — REViE IED0 CODE COMPLIANCE JAN - 2 2008 City Of Tukwila BUILDING DIVISION SANITARY STACK SCALE: NONE 2" TRAP I - 1/2" 1 -1 /2" 1 -1/2" TRAP 1/2" 1 2" 1 -1/2" j. 11 -1/2' I h— I 11 -1/2" i'�.> 1 1 . 1 1 -1/2 " LA I I 1 REMARKS ADA COMPLIANT, VITREOUS CHINA, ELONGATED SIPHON ACTION, 1.6 GPF, HANDLE ON OPPOSITE SIDE FROM WALL, AMERICAN STANDARD SEAT #5325.024. GC TO PROVIDE: 3/5" C.P. SUPPLY WITH LOOSE KEY STOP AND 15" MTG. HT. TO BOWL. WALL MOUNTED 15.5 "x20" VITREOUS CHINA, 4 -INCH CENTERS, WHITE COLOR WITH AMERICAN STANDARD FAUCET #7502.170.002 (INCLUDES WRIST BLADES, GRID STRAINER AND GOOSENECK). GC TO PROVIDE: .JOSAM 17105 -67 SERIES CARRIER, MCGUIRE SUPPLY STOP #155 -NC AND MOUNT SINK AT WHEELCHAIR HEIGHT. WALL MOUNTED SPLIT -LEVEL DRINKING FOUNTAIN. GC TO PROVIDE: BALL VALVE ON SUPPLY LINE AND TRAP. 24 "x24 "x10 ", MOLDED "DURASTONE" WITH VINYL BUMPERGUARD #63.401, MOP HANGER #65.600, HOSE AND BRACKET #65.700 AND AMERICAN STD. FAUCET NITH INTEGRAL VACUUM BREAKER #5344.112.002. 120V -I0, 10 GALLON ELECTRIC WATER NEATER WITH 1.5 KW ELEMENT, FACTORY INSTALLED 3/4" T *P RELIEF VALVE. GC TO PROVIDE: 3/4" COPPER DRAIN LINE FROM T$P VALVE TO MS -1. SHUT -OFF VALVES IN CW AND PIN LINES, UNIONS IN CW AND 1--1N LINES AND INSULATED HEAT TRAPS IN HN AND CW LINES PER MANUFACTURER REQUI REMENTS AND PER ASHRAE RECOMMENDATIONS. REMARKS 3" NITH NIKALOY STRAINER. OR EQUAL BY PRECISION PLUMBING PRODUCTS, INC. FLOW ACTIVATED BRONZE TRAP SEAL PRIMER WITH INTEGRAL VACUUM BREAKER, 1/2" SWEAT INLET AND OUTLET CONNECTIONS, AND 1/2" IP5 DRIP LINE CONNECTION. CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO SE GAS AND WATER TIGHT. WALL ACCESS PANEL -- 9"x9" NALL PANEL AND FRAME; SMOOTH NICKEL BRONZE PANEL SET FLUSH TO FINISHED WALL PLANE. FURNISI -1ED WITH SECURING LUGS. (CONC. FLOOR) OR ZN- 1400 -2 (TILE FLOOR). CAST IRON BODY NITH GAS AND WATER TIGHT ABS TAPERED THREAD PLUG AND ROUND SCORIATED TOP ADJUSTABLE TO FINISH FLOOR. FD -1 — FCO 2" NCO 4" WC - HANGERS INSTALLED EACH SIDE OF EXPANSION TANK FOR SUPPORT. Z AMTROL ST -5 THERMAL EXPANS I ON ABSORBER. BALL VALVE BY GC (TYP.). 3 /4 "T$PRELIEF VALVE BY GC. 3/4" RUN FULL SIZE TO MOP SINK. DRAIN VALVE BY GC: PLYWOOD PLATFORM BY GENERAL CONTRACTOR. D � r WCO FCO PLUMBING SYMBOLS & ABBREVIATIONS CW- - - HW— G —SAN ---- �-COND - - -V - - - - - — (E)XX -- o--rj PIPE - UP C� PIPE - DOWN ® ACCESS DOOR DOMESTIC WATER PIPE DOMESTIC HOT WATER GAS PIPE SANITARY PIPE CONDENSATE PIPE SANITARY VENT PIPE EXISTING PIPE OR EQUIPMENT BACK FLOW PREV. I*1 COMBINATION BALANCE /SHUT -OFF I■ r �! GATE VALVE I: 1 GLOBE VALVE l—� DRAIN VALVE CHECK VALVE UNION GAGE COCK CHECK VALVE ICI 111 I I�I 1'01 101 Y -TYPE STRAINER A. AFF. ARCH. BEL. BLDG. CLG. CO COND CONT. GIN CONTR. COORD. DISC. DN. BUTTERFLY VALVE BALANCE VALVE OR GAS VALVE BALL VALVE CAPPED LINE CONNECT TO EXISTING ABOVE ABOVE FINISHED FLOOR ARCH ITECT BELOW BUILDING CEILING CLEAN OUT CONDENSATE PIPE CONTI NUATI ON COLD NATER CONTRACTOR COORDINATE DISCONNECT DONN EA, EX. ENC FCO FD FIXT FPC. EACH EXISTING ELECTRIC WATER COOLER FLOOR CLEAN OUT FLOOR DRAIN FIXTURE FIRE PROTECTION CONTRACTOR FIRE PROTECTION PIPE FURNISH FLUSH VALVE GAS GALLON GENERAL CONTRACTOR GALLONS PER HOUR GPM. GALLONS PER MINUTE HOSE BIBB HEATING CONTRACTOR HORSEPOWER HOT WATER LAVATORY MAXIMUM MANUFACTURER MOUNT NOT TO SCALE PLUMBING CONTRACTOR PLSG. PLUMING R RELOCATE RD ROOF DRAI SAN SANITARY TYP. TYPICAL URINAL V VENT VTR VENT THROUGH ROOF NC WATER CLOSET NCO WALL CLEAN OUT NH WATER HEATER N/ WITH FP FURN. FV. GAL. GC. GPH. 1-13 HC. HP. HW LAV MAX. MFR. MT. NTS. PC. 3/4" u 3/4" : 7 7 ) STACK h WATER HEATER DETAIL SCALE: NONE RISER \M3.0 PARTIAL PLUMBING PLAN SCALE:1 /4" 1'_0" VACUUM BREAKER BY GG (TYP.) INSULATE ALL PIPING I N ACCORDANCE WITH SPECIFICATIONS. I NSTALL HEAT TRAP AT INLET AND OUTLET AS REQUIRED. UNION BY GC (TYP.) WATER HEATER SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. 2" WIDE, 20 GA. SHEET METAL BAND, SECURE TO WALL FOR SEISMIC ,d,,,,../— BRACING WHERE REQUIRED BY CODE. GALV. DRIP PAN 6' I ` / BY GC . // SEPARATE 3/4" DRAINS TO TO MOP SINK. PLUMBING GENERAL NOTES 1. UNLESS OTHERWISE SPECIFIED, GENERAL CONTRACTOR SI -IALL PROVIDE ALL NECESSARY EQUIPMENT, MATERIAL, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE PLUMBING WORK IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS. 2. FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND COLD WATER SUPPLY PIPING ABOVE CEILING PRIOR TO COMMENCEMENT OF ANY WORK. AFTER INSTALLATION AND FINAL CONNECTION OF NEN WASTE PIPING BELOW $LAS, BACK FILL AND PATCH IN ACCORDANCE WIT1 -I THE LANDLORD'S CRITERIA REGARDING SUCH WORK. 3. GENERAL CONTRACTOR SHALL INSTALL ALL PLUMBING FIXTURES AS PROVIDED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE AND Sl -IALL FURNISH AND INSTALL ALL REQUIRED VALVES, PIPING, HANGERS, ETC. REQUIRED FOR A COMPLETE PLUMBING SYSTEM TO SERVE THE DEMI55D PREMISES FROM SANITARY AND COLD WATER CONNECTIONS PROVIDED BY LANDLORD. ALL FIXTURES, VALVES, PIPING AND APPURTENANCES REQUIRED FOR A FULL ROUGH -IN SHALL BE FURNISHED AND IN IE CONTRACTOR $HALL PROVIDE A CAPPED TEE FOR POSSIBLE FUTURE CONNECTION (IF REQUIRED BY THE LANDLORD). 5. SEAL AROUND ALL PIPES PENETRATING FIRE SEPARATIONS WITH LISTED AND APPROVED FIRE SEAL MATERIAL. ONLY LISTED AND APPROVED SEALANTS AND METHODS FOR THE SPECIFIC USE WILL BE PERMITTED. 6. GENERAL CONTRACTOR SHALL ENSURE THAT ALL SLAB OR FLOOR PENETRATIONS WITHIN THE DEMISED PREMISES ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT ANY POSSIBLE DAMAGE TO THE BUILDING AND /OR SURROUNDING AREAS. FAILURE TO DO SO SHALL BE AT THE RISK AND SOLE EXPENSE OF TI-IE GENERAL CONTRACTOR. 7. ALL MATERIAL SHALL BE NEN AND OF COMMERCIAL GRADE, AND BEAR UNDERWRITER'S LABORATORIES AND UNION LABELS WHERE SUCH LABELING APPLIES. 5. GENERAL CONTRACTOR TO FIELD VERIFY SLOPE AND ELEVATION OF EXISTING SEWER PRIOR TO ANY NEW PLUMBING INSTALLATION. 9. GENERAL CONTRACTOR MUST VISIT TI-IE JOBSITE TO BECOME FAMILIAR WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS AND OTHER EXISTING JOB CONDITIONS THAT MAY AFFECT THE WORK. ADDITIONALLY, GENERAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS WASTE, VENTS, WATER LINES, ETC. 10. GENERAL CONTRACTOR SHALL FOLLOW ALL SPECIFICATIONS AND DETAILS CONTAINED IN DESIGN CRITERIA OF TENANT HANDBOOK AND OTHER LANDLORD REQUIREMENTS. 11. GENERAL CONTRACTOR TO CLEAR ALL EXISTING AND NEW DRAIN LINES AND FIXTURES, PRIOR TO TURNING OVER SPACE TO TENANT. 12. GENERAL CONTRACTOR SHALL- PROVIDE ACCESS TO VALVES, TRAP PRIMERS, ETC. INSTALLED BEHIND WALLS, FLOORS OR CEILINGS. 13. ALL PLUMBING FIXTURES SHALL SE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. 14. ANY EXISTING WALL /FLOOR OR CEILING SURFACE THAT IS DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED TO MATCH NEW AND /OR EXISTING CONDITIONS AT GENERAL CONTRACTOR'S EXPENSE. 15. GENERAL CONTRACTOR SHALL DEMOLISH AND COMPLETELY REMOVE ALL PLUMBING FIXTURES, EQUIPMENT, PIPING, ETC. NOT BEING REUSED OR SERVING ANOTHER SPACE. CAP ALL PIPES SEHIND FINISHED SURFACES (WALLS, FLOORS, ETC.) AND PATCH SURFACES TO MATCH SURROUNDING AREA. 16. FIELD VERIFY ALL CONDITIONS PRIOR TO BID. REFER TO RESPONSIBILITY SCHEDULE ON SHEET M2.0 FOR MORE INFORMATION PLUMBING CODED NOTES C 1) ( 2) ( 3 ) C 4 ( 6 ) ( 7 ) ( 5 ) ALL WATER LINES, VENT LINES, DUCTWORK, DRAIN LINES, SPRINKLER LINES, ETC. SHALL SE OFFSET BELOW PLATFORM AND CONCEALED IN NALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETC. THROUGI -I STORAGE SPACE ABOVE PLATFORM OR ABOVE ELECTRICAL EQUIPMENT. EXTEND SANITARY LINE TO LANDLORD'S EXISTING SANITARY SERVICE. FIELD VERIFY EXACT LOCATION OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEAN OUT AT CONNECTION TO LANDLORD'S MAIN AND COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR EINISH WITH DELIA'S CONSTRUCTION MANAGER. PATCH SLAB TO MATCH SURROUNDING AREA. COORDINATE PATCHING REQUIREMENTS WITH GENERAL CONTRACTOR. NEW SANITARY LINE SHALL SE PRESSURE TESTED PER LOCAL CODES NITH A MINIMUM REQUIREMENT OF HOLDING 10 FT. W.C. FOR TWO HOURS. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. EXTEND 3" VENT LINE TO LANDLORD'S EXISTING VENT CONNECTIONS. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS WITH LANDLORD AND EX ISTING CONDITIONS PRIOR TO BID. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. EXTEND NEW COLD WATER LINE TO THE EXISTING COLD WATER TAP. FIELD VERIFY EXACT LOCATION AND SIZE OF CN PRIOR TO BIDDING. NOTIFY DELIA'S CONSTRUCTION MANAGER IF TAP IS SMALLER THAN 51401ALN ON RISER DIAGRAM. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. FURNISH AND INSTALL WATER HAMMER ARRESTERS IN THE DOMESTIC COLD AND HOT WATER PIPING AS 51-IOWN ON THE WATER RISER DIAGRAM. WATER HAMMER ARRESTERS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE. INSTALL 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION. ALL PLUMBING FIXTURES SI -IALL SE INSTALLED WITH STOP VALVES TO ISOLATE EACI -I FIXTURE. REFER TO PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. PROVIDE WATER METER WITH REMOTE READER PER LANDLORD'S AND NATER COMPANY REQUIREMENTS. MOUNT ON PLATFORM ABOVE RESTROOM WHERE ACCESSIBLE. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. INSTALL NEW TANK TYPE WATER HEATER ON PLATFORM ABOVE RESTROOM AS FURNISHED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE. ROUTE DRAIN LINE TO MOP SINK. SEE RISER DIAGRAM, PLUMBING FIXTURE SCHEDULE AND DETAIL D ON THIS SHEET FOR REQUIREMENTS. RECEIVED CITY OF TUKWH A DEC 1 8 2007 PEWIT CEN I ER W J W 1 u) CO -J Z 1- E3 w 2 CI Z DRAWING NUMBER: *an EttsL3 Wx .,,,, <gEN aw =, c6 ¢ � W A ,_ Uswil c< m W co w 1:3 (/) M3.0 THEENGINEERASSUMESNO SPONSIBILITYOR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL. THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA SA1 # 07418