Loading...
HomeMy WebLinkAboutPermit 4432 - Trammell Crow - Pavilion Outlet Mall - ReroofCITY OF TUKWILA 1 Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 BUILDING PERMIT 6 PERMIT # 14(//3L2 Control # 85 -276 Work to be done Reroof Site Address 17900 Southcenter Parkway Suite # Tenant Pavilion Outlet Center Building Use Retail Assessors Account # 352304 - 9061 -0 Property Owner Trammell Crow Phone # 762 -4750 Address 5601 Sixth Ave. So., Seattle, WA Contractor Custom Roofing, Inc. #CUSTOR *291M9 Address 8001 Fifth Ave. So., Seattle, WA Zip 98108 Phone f 762 -0170 Zip 98108 FOR BUILDING PERMIT ONLY Approved for issuance by Sq. Ft. Office Storage/ re e Wa hou s Retail Other Occ. Load 1st F1. 2nd F1. 3rd F1. Total Fire Protection: Q Sprinklers Q Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ sq. ft. @ sq. ft. @ sq. ft. @ 1st F1. $ 2nd Fl. $ other $ other $ Total Valuation of Construction $ 69,600 Bldg. Permit Fee Receipt # L(b $ 505.00 Plan Check Fee Receipt # $ 1.50 Demolition Receipt # $ Surcharges Receipt # $ Other Receipt # $ Other Receipt # $ TOTAL $ 506.50 FOR SIGN PERMIT ONLY Q Permanent [] Temporary Q Single Face Q Double Face Q Wall Mounted Q Free Standing [[ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK 15 SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT l HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE ()I /CAN L PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. ned c { Date -Z7 LICENSED CONTRACTORS DECLARATION hereby affirm that 1 am licens d u r provisions of the Business and Professions Code, and my license is in full force and effect. Z � C ntractor (signature) Z it,/, l -0*� Date OWNER- BUILDER DECLARATION ( 1 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( 1 I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature) Date CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done Reroof Site Address Building Use Property Owner Address Contractor Address BUILDING PERMIT PERMIT # Control # 85 -276 17900 Southcenter Parkway Suite # Tenant Pavilion Outset Center Retail Assessors Account # 352304- 9061 -0 Trammell Crow Phone # 762 -4750 5601 Sixth Ave. So., Seattle, WA Custom Roofing, Inc. #CUSTOR *291M9 8001 Fifth Ave. So., Seattle, WA FOR BUILDING PERMIT ONLY A roved for issu S Ft. Sq. Office Warehous Warehouse Retail Other Occ. Load 1st F1. 2nd Fl. 3rd Fl. Total Fire Protection: (] Sprinklers [[ Detectors Zoning Type of Construction Special Conditions Zip 98108 Phone # 762 -0170 Zip 98108 Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 69,600 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt #D ,tfb $ 505.00 Receipt #2C?() $ 1.50 Receipt #'" $ Receipt # $ Receipt # $ Receipt # $ $ 506.50 FOR SIGN PERMIT ONLY Q Permanent (] Temporary Ei Single Face Double Face [] Wall Mounted [] Free Standing [( Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DUES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR ANCJL '13E PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION 77OR THE PERFORMANCE OF CONSTRUCTION. pnedC ! / "-°^1 Date ?,.'� C• .1aL LICENSED CONTRACTORS DECLARATION 1 hereby affirm that I am licens d upd&r provisions of the Business and Professions Code, and my license is in full force and effect. � ohtractor (signature) e .L 1�(A-- 1- l -nt.� Date Z )-- { 1�) OWNER - BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Date Owner (signature) avow UfVtfAi. MM. ..CITY OF TUKWILA 6uiiding Division 6200 Southwntsr Boulevard Tukwila, Washington 98188 (206) 433 -1849 . . ............... ...»w../ uKxv...0 a ••:.•,cvw•Adv.••r..xricux./tsi• INSPECT(IN RECORD PERMIT # W302 Date /y/iyee Type of Inspect 7 -4 Date Wante /f 1K Site Address /7761r, Se 0 i' Project ae/4-1-6e;1 (_,10-4-61€01) Requestor Phone # Special Instructions 4h #�- Inspection Results /Comments: ,,dte Inspector fio-r-144 Date /%0)0Z. >., . I' .eV44.4 ei as .%c. 8001 5TH AVENUE SOUTH SEATTLE, WASH. 98108 PHONE 762-0170 'TO: City .of Tukwila DATE: 12/17/fth 6200 Southcenter Blvd. Tukwila, Washington 98188 SUBJ: ROOFING yy3 PROJECT: Trammell Crow ( Pavilion ) 17900 sSouthcen r. Parkway Tukwila, Wa@jli.ngton GENTLEMEN: Custom Roofing has installed a new built up roofing membrane in compliance with the following specifications. OWENS- CORNING SPECIFICATION # 31 T.Q. INSULATION 3/4" Fiber lass Per Owens— Corning specifications this roof has a Class HHAI! _UAL.__ rating over 3 /L" Fibergiaza ' n a u1 on Please see copy of specification attached. Sincerely, Custom Roofin FIBERGLAS `t Insulated /Cap Sheet r. _ . 33 1C r 31.-x.. PERMA PLY -R PER MA-PLY-hi 33 -IC All Areas 31 -IC All Areas Application of Insulation Apply roof insulation in accordance with specification requirements. Insulation joints should be staggered in one direction. For multiple -layer applications, joints of each layer should be offset a minimum of 6 inches from all joints of the preceding layer. Application of Plies Embed three plies of PERMA PLY in shingle fashion (starter sheets required), lapping 24 -2/3 inches into uniform solid moppings of hot asphalt, using a nominal 25 lb/100 ft? per ply. Plies may be left exposed up to six months without surfacing. Application of Mineral Surface Embed 12 -ft, lengths of PERMA CAP (18 -ft. in Area III) with 2 inch side and end laps into a uniform solid mopping of hot steep asphalt, using a nominal 25 lb/1001t2. PERMA CAP end laps should be staggered 3 ft. Interply/ Surfacing/ Slope Nominal Installed lb /100 ft2 (Below weights exclude roof insulation and are provided for system design consideration) 33 -IC 31 -IC 202 202 Application of Insulation Apply roof insulation in accordance with specification requirements. Insulation joints should be staggered in one direction. For multiple -layer applications, joints of each layer should be offset a minimum of 6 inches from all joints of the preceding layer. Application of Plies Embed three plies of PERMA PLY in shingle fashion (starter sheets required), lapping 24 -2/3 inches into uniform solid moppings of hot asphalt, using a nominal 25 lb/100 ft? per ply. Plies may be left exposed up to six months without surfacing. Application of Mineral Surface Embed 12 -ft, lengths of PERMA CAP (18 -ft. in Area III) with 2 inch side and end laps into a uniform solid mopping of hot steep asphalt, using a nominal 25 lb/1001t2. PERMA CAP end laps should be staggered 3 ft. Interply/ Surfacing/ Slope Bitumen Type Materials per 100 ft2 Interply Felts 3 plies Bitumen 0 -1/2" H, III 75 Ibs 1/2-3" III 75 lbs 3 -6" IV 60 Ibs Surfacing Asphalt 0 -3" 111 25 Ibs 3 -6" IV 20 Ibs PERMA CAP 78 Ibs General Note All general instructions contained in the General Requirements section shall be considered part of this specification. Drainage Roof decks must he graded to drain all water freely. Drains shall be sufficient in number and size to assure rapid elimination of water from the roof surface. Nailing Treated wood nailers are required on inclines exceeding 2 inches per foot to help secure insulation and roof membranes to non.nailable decks or to decks with insulation. Nailers should be the same thickness as the insulation and should be installed perpendicular to the slope on 8 foot face-to-face for slopes up to 3 inches per foot and 4 foot face -to- face for slopes greater than 3 inches per foot. Felts are to run parallel to the incline and must be secured at each nailer, 12" in from the back edge of the felt. Each nail must be covered by succeeding plies. High temperature areas may require nailing on lower slopes. Fleshings See Flashing Section. Ply Edge in Ply Edo. PERMA PLY Pllss 1.. N el Ply lu Nml 33 UL' Specification Index Class Surface A Gravel Specifications Perma PIyR Perma PIyIV 43 -IG 33 -1G 23 -TG 4P -IG 3P -IG 43 -FG 33 -FG 4P -FG 3P -FG 43 -NG 33 -NG 4P -NG 3P -NG 43 -XG 33 -XG 4P -XG 3P -XG 41 -IG 31 -IG 21 -TG 41 -FG 31 -FG 41 -NG 31 -NG 41 -XG 31 -XG Maximum 3" 3" 3" 1/4" t /4„ 3" 3" Y4" 1/4" 3" 1/4,, 1/4" 3" 3" . t /4" 1/4„ Deck Type NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC; C; PL NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC;C;PL NC;C ;PL • Insulation2 Min. Thickness Max. Thickness 3/4" FG, P, W(NC Deck Only) 3/4" FG, P W(NC Deck Only) 3/4" FG, P W(NC Deck Only) 3/4" FG, P WING Deck Only) 3/4" FG, P WINC Deck Only) 1.3" 0 1.3" 0 1.3" 0 1.3" 0 N/A N/A N/A N/A N/A N/A N/A N/A 3.25" 0 3.25" 0 3,25" 0 3.25" 0 N/A N/A N/A NIA N/A N/A N/A N/A Mineral Cap 43 -IC 33 -IC 23 -TC 43.FC 33 -FC 43 -NC 33 -NC 43•XC 33 -XC 21 -TC 41 -FC 31 •FC 41-NC 31 -NC 41 -XC 31 -XC 2" 2" 2" 2" 2" 2" 1/2" 2" V2" 2" 1/2" 2" NC;C;PL NC;C;PL NC ;C;PL NC NC NC C;PL NC C;PL NC C;PL NC C; PL 3/4" FG; 1" P (Max. 1" Slope) • 3/4" FG; 1" P (Max. 1" Slope) 3/4" FG 1.3" 0 1.3" 0 N/A N/A N/A N/A Emulsion 43.IS 41 -IS 33 -IS . 31 -IS 33 -TS 31 -TS. 43 -NS .41 -NS 43 -XS 41 -XS Aluminum 43 -IS 41-1S 33 -IS 31 -IS Unsurfaced 43 -IS 41 -IS 33•IS 31-IS 43 -NS 41 -NS 43 -XS 41 -XS 3" 3„ 3" 3" 3', 2" 2" 3" 3„ 3" 3" NC NC NC NC NC NC NC NC NC NC NC 3A" FG, P 3 /4 " FG, P 3/4" FG, P N/A N/A 3/4" FG, P • 3/4" FG, P 3/4" FG; 3/4" P 3/4" FG; 3/4" P N/A N/A 3.25" 0 3.25" 0 N/A N/A N/A N/A 1" FG, P 1 " FG, P 1" FG, P N/A N/A 1 " FG, P 1" FG, P 1" FG; 1" P 1" FG; 1" P N/A N/A Legend Deck NC Non - Combustible C Combustible PI_ Plywood (1/2" Min Roof Insulation FG = Fiberglas 0 = OCFoam P " Perlite W Wood Fiber N/A = Not Applicable Footnotes 1 (11 listings most bit tofuiriot to nhinin slim:die products, lines, ihicknassoe, slopes and acceptable application methods. 2 For vapor retarder approvals, uses and slopes refer to individual U.L. listings. ' APPLICATION FOR BUILDING PERMIT CITY OF TUKWILA 1 CONTROL JOB ADDRESS 17500 Or Southeentor Parkway TENANT Parkway Plaza So / Bldre. DATE OF APPL. Ai i iit 20, 19 ;6 DESCRIPTION OF USE Retail / Multiple Tenants LEGAL DESCRIPTION ATTACHED a PROPERTY OWNER Tram()1i Crow Campanv ADDRESS 5&)1 ;31xth Ave„ ' uth, Seattle PHONE 762-4750 ENGINEER /ARCHITECT ADDRESS PHONE CONTRACTOR Cuotom Roofint , Inc. ADDRESS 8001 Fifth Ave, ;south, Seattle PHONE 762. -0170 AUTHORIZED AGENT LICENSE NO. CUS cap. 2;i1M9 VALUE OF WORK 1' 33,500 FIRE PROTECTION SYSTEM SPRINKLER )2Y DETECTOR USE ZONE TYPE OF CONST T OOFINQ ADJUSTED VALUE GRADING CUBIC YARDS CUT FILL SIZE OF BUILDING SIZE OF UNIT WORK TO BE DONE: Install one U:lv Of 72 / cap sheet. 1ST FL. •i :30¢000 F. 2ND FL. TOTALS 130 000 So Ft, I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICA• TION AND KNOW THE SAME TO BE TRUE AND CORRECT. FEES AMT. DATE REC. NO REC. BY P.C. SIGNATURE Cuatoia Roofing:;,, Inc. ADJ. B.P. DEMO, -- COMPANY / DATE 86 2086 PHONE 762 "0.170 TOTAL CITY USE ONLY USES SO. FT. OCC. OCC. LOAD TOTALS DEPT. APPROVALS SENT CORR, APPR, PLANNING HEALTH PUBLIC WORKS FIRE SPECIAL CONDITIONS PLAN CHECKED BY DATE APPROVED FOR PERMIT BY DATE