Loading...
HomeMy WebLinkAboutPermit 4490 - Koll Business Center - Koll 22 - ReroofCITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 BUILDING PERMIT PERMIT # v/190 Control # 86 -346 Work to be done Reroof Site Address 900 916Industry Dr Suite # Tenant Koll #LL Building Use Office /warehouse Assessors Account # 252304 -9015 Properly Owner Koll Business Center Phone # 643 -1776 Address 2021 152nd Ave. NE, Rdemond, WA Zip 98052 ,`, Contractor Pacific Rainier Roofing #PA- CI- FR- R248LC Phone # 367- 5 Address 10735 Stone Ave. N, SEattle, WA FOR Zip 98133 BUILDI NG PERMIT ONLY Approved for Issuance By / �� al ;� , . / � S Ft. Sq. Office Storage/ Warehouse Retail Other Occ. Load 1st F1. 2nd Fl. 3rd Fl. Total Fire Protection: C1 Sprinklers [[ Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st Fl. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 26,608 Bldg. Permit Fee Receipt #3802 $ 265.00 Plan Check Fee Receipt # $ Demolition Receipt # $ Surcharges. Receipt #3802 $ 1.50 Other Receipt # $ Other Receipt # $ TOTAL $ 266.50 FOR SIGN PERMIT ONLY [I Permanent (l Temporary [] Single Face [] Double Face [] Wall Mounted L] Free Standing [] Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Special Conditions Total square footage of sign THIS PERM1f BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT l HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS YPE OF ORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR ,GA11CtL ffNf j °VISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE_RFORMANCE OF CONSTRUCTION. / Date (! '�(3 LICENSED CONTRACTORS DECLARATION vI hereby affirm that I am cen ed u .e provisions of the Business and Professions Code, and my license is in full force and effect. Date l ! 7 OWNER - BUILDER DECLARATION ( ) I, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature) Q_Signed ontractor (signature) Date CITY OF TUKWILA Building Division k. 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done Reroof Site Address 900 916lndustry Ur Building Use Office /warehouse Propenty Owner Koll Bus9ness Center Address 2021 152nd Ave. NE, Rdemond, WA Contractor Pacidic Rainier Roofing #PA- C1- FR- R248LC Address 10/35 Stone Ave. N, SLattie, WA FOR BUILDING PERMIT ONLY Approved for Issuance By t a BUILDING PERMIT PERMIT # q6/47() Control # 86 -346 J Suite # Tenant Ko 1 Tifi2z Assessors Account # 2b2304-9Ulb Phone # 643 -1 //b Sq. Ft. Office Storage/ Ware house Retail Other Occ. Load 1st F1. 2nd Fl. 3rd F1. Total Fire Protection: 1 Sprinklers [J Detectors Zoning Type of Construction Special Conditions Zip 9802 Phone # 3a Zip 9613s IL; Fees sq. ft. @ sq. ft. @ sq. ft. @ sq. ft. @ 1st F1. 2nd F1. other other Total Valuation of Construction Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL $ $ 26,608 Receipt #3802 $ 265.00 Receipt # $ Receipt # $ Receipt #3802 $ 1.50 Receipt # $ Receipt # $ $ 266.50 FOR SIGN PERMIT ONLY 0 Permanent [] Temporary [[ Single Face Q Double Face D Wall Mounted [] Free Standing [I Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK 1S SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS YPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO '',,''VIOLATE OR AF NC L HE ROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. .Signed IIV � / ,.,...r Date / 11 --(3 / 7')/ LICENSED CONTRACTORS DECLARATION l hereby affirm that I am )icen ed under provisions of the Business and Professions Code, and my license is in full forCc/r and effect. (signature) j /� Date / ? - h Contractor (si nature) � �' �,i � � ^'� OWNER- BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) 1, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Oate__, Owner (signature) CITY OF TUKWILA Building Division A200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1849 INSPEC :2N RECORD PERMIT # Date Type of Inspection / /r7417/ (,_e,_-c,oic) Date Wanted a.m. p.m. Site Address ?DO- 9/, „may, /usa -y j/-. Project Requestor Phone # Special Instructions Inspection Results /Comments: Inspector ,de;:e,i;;;7 Date 1PA /�? PACIFIC RAINIER ROOFING, INC. 10735 Stone Avenue North Seattle, Washington 98133 -8996 Phone (206) 367 -2525 223- 01- PA- CI- FR- R248LC September 29, 19$7 FORM LETTER City of Tukwila 6200 Southcenter Blvd. Tukwila, WA 9$1$$ Attention: Building Dept. Reference: Building Permit #4490 Subject: Notice of Completion Gentlemen: Pacific Rainier Roofing, Inc. has installed a roof membrane as- sembly consisting of a Tamko Spec #134 (data sheet enclosed), which meets the requirements for Class A or Class B roofs. This roof was installed for Koll Business Center at Building #22 900- 916 Industry Dr. Tukwila, WA 9$1$$ under Building Permit #4490. Please notify this office of your final inspection and acceptance. If we may of further assistance, please advise. DKU /rsh Enclosures Sincerely, PACIFIC RAINIER ROOFING., INC. D.K. Unrue - an equal opportunity employer -- • t. PACIFIC RAINIER ROOFING, INC. 10735 Stone Avenue North Seattle, Washington 98133 -8996 Phone (206) 367 -2525 223- 01- PA- CI- FR- R248LC September 29, 19$7. FORM LETTER City of Tukwila 6200 Southcenter Blvd. Tukwila, WA 9$1$$ Attention: Building Dept. Reference: Building Permit #4490 Subject: Notice of Completion Gentlemen: Pacific Rainier Roofing, Inc. has installed a roof membrane as- sembly consisting of a Tamko Spec #134 (data sheet enclosed), which meets the requirements for Class A or Class B roofs. This roof was installed for Koll Business Center at Building #22 900- 916 Industry Dr. Tukwila, WA 981$$ under Building Permit #4490. Please notify this office of your final inspection and acceptance. If we may be of further assistance, please advise. Sincerely, PACIFIC RAINIER ROOFING, INC. D.K. Unrue DKU /rsh Enclosures - an equal opportunity employer CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 BUILDING PERMIT Work to be done ,', :rouf Site Address 1c' Ur Building Use ufr ic,: ;war6house Property Owner ,.c.):; -'.:sJn ss CL)l :ter Address L,L1 i ;/t ;i , -ue und, WA Contractor kai ,er Address El3a 5Lon� Ave. PERMIT # ! , /' -//.(. Control # x-34,; Suite # Tenant Assessors Account # Phone # .=,J-1/!b Zip Phone # FOR BUILDING PERMIT ONLY .- 2provuu =ter Issuance 1 4 . S Ft. Sq. • Office WarehousOcc. s =lie Retail Other , Load 1st Fl. 2nd Fi. 3rd F1. Total Fire Protection: ❑ Sprinklers ❑ Detectors Zoning Type of Construction Special Conditions Zip Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ L5.(A;0 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt # L $ ) . .( Receipt # $ Receipt # $ Receipt #;2;2 $ i.Z0 Receipt # $ Receipt # $ $ :c: ,;r FOR SIGN PERMIT ONLY ❑ Permanent ❑ Temporary ❑ Single Face ❑ Double Face ❑ Wall Mounted ❑ Free Standing 0 Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 GAYS AT ANY TIME AFTER WORK 1S COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR L ,FANG THE ,PROVISIONS Of ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE_, PERFORMANCE OF CONSTRUCTION. Signed �,� ;1. Date `/n f LICENSED CONTRACTORS DECLARATION 1 hereby affirm that 1 am licensed updes provisions of the Business and Professions Code, and my license is in full force and effect. • r - '• Contractor (signature) ' . i. /Lt ), Date , OWNER- BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole ccopensation, will do the work, and the structure is not intended or offered for sale. ( ) I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature) Date c TYPE III STEEP ASPHALT TAMKO VAPOR•CHAN VENTING BASE SHEET SPOT MOP ON 12.24' CENTERS WITH TYPE III, STEEP ASPHALT A ••LAN/ AWAPLAN 170 GRANULE SURFACED XISTING GRAVEL SURFACED MEMBRANE (BROOM GRAVEL AND PRIME) 12.0 TAMKO RE- ROOFING SYSTEMS 12.1 RE- ROOFING OVER EXISTING GRAVEL SURFACED MEMBRANE (ASPHALTIC COMPOSITION) Specification 131 (Regular)/131 HW (Heat Welding/231 (AWAPLAN 170) 12.1.1 Slope Positive drainage up to 11/2 in. per lineal ft. 12.1.2 Material Per Requirements 100 Sq. Ft. TAMKO VAPOR -CHAN Fiberglass Venting Base Sheet 1 Ply TAMKO AWAPLAN REGULAR or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt As specified Concrete Primer Approx. 3/4 Gal, 12.1.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM D- 312 -84, Type III. (See Section 6.6 for more details.) 12.1.4 Preparation: Broom the membrane surface and remove all of the loose roofing gravel and debris. Make random cuts or breaks in the old membrane 4 ft. o.c. to allow vapor pressure to vent. All wet or deteriorated insulation or membrane must be removed and replaced prior to the application of new roofing mate- rials. The surface should be primed with TAMKO Concrete Primer at a rate of approxi- mately 2/4 gal. per 100 sq. ft. prior to the application of new roofing materials. 12.1.5 TAMKO VAPOR -CHAN: Over the old mem- brane and starting at the low point of the roof, install one ply of TAMKO VAPOR -CHAN base sheet. The VAPOR -CHAN should be side lapped 2 in., and end lapped 4 in. The base ply should be secured to the old membrane with spots of Type III, Steep Asphalt spaced on (not to exceed) 24 in. centers. 12.1.6 AWAPLAN Regular or AWAPLAN 170: Starting at the low point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in. The AWAPLAN or AWAPLAN 170 should be solidly adhered to the base ply (pressed into the hot asphalt) with approximately 30 lbs. (± 15%) of speci- fication asphalt. 12.1.7 AWAPLAN Heat Welding: Starting at the low point of the roof, install one ply of TAMKO welding grade AWAPLAN, side lapped 4 in., and end lapped 6 in. The AWAPLAN should be solidly adhered to the base ply by heating the back -side with a torch at the junc- ture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.1.8 Flashing: The flashing material must be AWAPLAN 170 surfaced ord AWAPLAN, VERSA -FLASH 160. e Sections 6.9 and 13.0 for more details.) 12.1.9 Venting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. TYPE III STEEP ASPHALT TAMKO VAPOR-CHAN VENTING BASE SHEET AWAPLAN/ AWAPLAN 170 GRANULE SURFACED SPOT MOP ON 12.24' CENTERS WITH TYPE III, STEEP ASPHALT EXISTING GRAVEL SURFACED MEMBRANE (BROOM GRAVEL - 00 NOT PRIME) 12.2 RE- ROOFING OVER EXISTING GRAVEL SURFACED MEMBRANE (COAL -TAR PITCH) Specification 132 (Regular) /132 HW (Heat Welding/ 232 ( AWAPLAN 170) 12.2.1 Slope Up to '/4 in. per lineal ft. 12.2.2 Material Per Requirements 100 Sq. Ft. TAMKO VAPOR -CHAN Fiberglass Venting Base Sheet 1 Ply TAMKO AWAPLAN REGULAR or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt As specified 12.2.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM D- 312 -84, Type III. (See Section 6.6 for more details.) 12.2.4 Preparation: Broom the membrane surface and remove all of the loose roofing gravel and debris. Make random cuts or breaks in the old membrane 4 ft. o.c. to allow vapor pressure to vent from the old system and any existing insulation materials. AU wet or deteriorated insulation or membrane must be removed and replaced prior to the application of new roof- ing materials. DO NOT.USE ANY PRIMERS. 12.2.5 TAMKO VAPOR -CHAN: Over the old mem- brane and starting at the low point of the roof, install one ply of TAMKO VAPOR -CHAN base sheet. The VAPOR -CHAN should be side lapped 2 in. and end lapped 4 in. The base ply should be secured to the old membrane with spots of Type III, Steep Asphalt spaced on (not to exceed) 24 in. centers. 12.2.6 AWAPLAN Regular or AWAPLAN 170: Starting at the low point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in. The AWAPLAN or AWAPLAN 170 should be solidly adhered to the base ply (pressed into the hot asphalt) with approximately 30 lbs. (-1.15%) of speci- fication asphalt. 12.2.7 AWAPLAN Heat Welding: Starting at the low point of the roof, Install one ply of TAMKO welding rade AWAPLAN, side lapped 4 in., and end lapped 6 in. The AWAPLAN should be solidly adhered to the base ply by heating the backside with a torch at the junc- ture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.2.8 Flashing: The flashing material must be granule surfaced TAMKO AWAPLAN, AWAPLAN 170 or VERSA -FLASH 160. (See Sections 6.9 and 13.0 for more details.) 12.2.9 Venting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. 07500/TAM Buyline 3120 AWAPLAN( AWAPLAN 170 GRANULE SURFACED TYPE III STEEP ASPHALT TAMKO VENT-PLY PUNCHED FIBERGLASS BASE SHEET EXISTING SMOOTH SURFACED MEMBRANE (PRIMED) 12.3 RE- ROOFING OVER EXISTING INORGANIC SMOOTH SURFACED MEMBRANE — Specification 134 0 (Regular) /134 HW (Heat Welding)/ 234 (AWAPLAN 170) 12.3.1 Slope Up to 3 in. per lineal ft. 12.3.2 Material Per Requirements 100 Sq. Ft. TAMKO VENT -PLY Punched Fiberglass Base Sheet 1 Ply TAMKO AWAPLAN REGULAR or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt Approx. 30 lbs. Concrete Primer Approx. 3 gal. 12.3.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM 0-312-84, Type III. (See Section 6.6 for more details.) 12.3.4 Preparation: Clean and prime the entire sur- face with 3/4 gal. of TAMKO Concrete Primer per 100 sq. ft. All wet or deteriorated insulation must be removed and replaced prior to the application of new roofing materials. 12.33 TAMKO VEN•PLY: Over the old membrane and starting at the low point of the roof, install one ply of TAMKO VENT-PLY Punched Fiberglass Base Sheet. Install the VENT-PLY by rolling out the sheet dry over the roof membrane, sprinkle mop to hold the sheet in place until the final course is installed. Side laps shall be 2 in. and end laps 4 in. 12.3.6 AWAPLAN Regular or AWAPLAN 170: Starting at the low point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in. The AWAPLAN or AWAPLAN 170 should be solidly adhered to the base ply (pressed into the hot asphalt) with approxi- mately 30 lbs. (-4.15%) of specification asphalt. 12.3.7 AWAPLAN Heat Welding: Starting at the low point of the roof, install one ply of TAMKO welding grade AWAPLAN, side lapped 4 in., and end lapped 6 in. The AWAPLAN should be solidly adhered to the base ply by heating the back -side with a torch at the juncture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.3.8 Flashing: The flashing material must be granule surfaced TAMKO AWAPLAN, AWAPLAN 170 or VERSA -FLASH 160. (See Sections 6.9 and 13.0 for more details.) 12.3.9 Venting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. 25 'TAM 1110 October 7, 1986 Mr. Monty Moore Pacific Rainier Roofing, Inc. 10735 Stone Avenue North Seattle, WA 98133 SUBJECT: U.L. APPROVAL TAMKO ROOFING SYSTEMS #134 & #234 Dear Mr. Moore: P. 0. BOX 1404 601 NORTH HIGH ST. AREA C006 14171 624.6644 JOPLIN. MISSOURI 64602 Please be advised that Tamko's Recover Specifications #134 and #234 are approved by U.L. as A, B or C when installed in compliance with the 1986 Building Materials Directory. The reference card is R3225 (N Item 5). The new card listing will allow the use of Vent -Ply or Vapor -Chan as the base ply. The surfacing options of fibered aluminum or emulsion will not change. If local code authorities require more information, they can call U.L. at 312 - 272 -8800. Sincerely, Richard McReynolds Western Regional Manager vn cc: W. Kent Blanchard John Kirby X.. Maccionalcii4Laren Associat ,nc Consulting Engineers October 3, 1986 Mr. Charles E. Scofield Koll Company 601 Strander Boulevard Tukwila, WA 98188 RE: Koll Business Center Additional Roofing Loans Dear Mr. Scofield, We have examined the structural drawings and have determined that the following buildings are capable of a 1.65 additional roof load: Building. 22, 26,30, 31, 36 and 42 (6 buildings). Sincerely, D. Bruce McLaren,.P.E. DBM /cmh -T- 1rnK0 #134 61$€. VENT PL/ AWRPL -P N ) 70. P5P H A-LY /,333 1/44).F7-. Ned J Macdonald. 0. Bruce McLaren James C. Peterson 215 Eighth Avenue North Seattie. WA 98109 206.622. 5SC t 1 City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433 -1800 Gary L. VanDusen, Mayor September 14, 1987 Pacific Rainier Roofing 10735 Stone Ave. N. Seattle, WA 98133 Attn: Monty Moore Re: Building Permits #4490, #4491, #4492, #4493, #4494, #4495 and #4496 Koll Buildings #22, #26, #28, #30, #31, #36, and #42 (reroof) Dear Mr. Moore: Our records indicate that these permits have not been finalled.by the Building Division. In order for us to sign -off on this project we need you to provide us with a written statement regarding compliance with the Uniform Building Code (1985 Edition) roof covering requirements. The attached handout provides you with an example statement. Please provide this information within 15 days of receipt of this letter or contact us with the status of this project. If you should have any questions, please contact me at 433 -1852. Sincerely, f. Norm Bray Building Inspector, 1 CITY Pr vy'1 re •Y ? cLc4v illto yt.c • Macdonald QLaren Associates; Consulting Engineers October 3, 1986 Mr. Charles E. Scofield Koll Company 601 Strander Boulevard Tukwila, WA 98188 RE: Koll Business Center Additional Roofing Loans Dear Mr. Scofield, We have examined the structural drawings and have determined that the following buildings are capable of a 1.65 additional roof load: Building 22, 26,30, 31, 36 and 42 (6 buildings). Sincerely, F D. Bruce McLaren, P.E. DBM /umh Neil J. Macdonald 215 Eighth Avenue North RECEIVE° CITY OF TUKWI A OCT 9 1986 BUILDING DEPT. D, Bruce McLaren Seattle, WA 98109 James C, Peterson 206.622.4580 4 n Malarkey BUILT-UP ROOFING SPECIFICATIONS NM3 NAILABLE DECK MINERAL SURFACED NAILABLE DECK FIBERGLASS PREMIUM 1 SBS BASE SHEET FIBERGLASS PREMIUM 1 PLY SHEET 1 34" ROOFING ASPHALT ZONE 3 (U.L. CLASS "A" — Up to 211„) u L-- CrASS- "rC" — 2 "t-66' Materials Per 100 Square Feet .&f rin-3tieratlir ,}-Ra ie- H44- paquipK4 1 pry_--- --frttrs Premium 1 SBS Base Sheet 1 ply 30 lbs. Premium 1 Ply Sheet 1 ply 11 lbs. Premium Cap Sheet 1 ply 75 lbs. Asphalt between Plies 50 lbs. General .requirements are applicable as part of this specification. APPLICATION: Over wood boards only, lay one ply of rosin sheath- ing paper. Lap each sheet at least 2" and nail suffi- ciently to hold in place. Apply Malarkey Premium 1 SBS Base Sheet so flow of water is over .or parallel to the laps. Lap each sheet 2" on sides and 6" on ends. Nail each sheet 9" on center through the laps and 18" on center along line 12" distance from each edge. Turn up 2" above cant at all vertical surfaces. Apply Malarkey Premium 1 Ply Sheet parallel to the base sheet and lap so water flow is over not against laps. All end laps shall be 4" and adjacent FIBERGLASS PREMIUM CAP SHEET end laps shall be 12" apart. The full width of each sheet shall be embedded in hot asphalt at the rate of 25 lbs. per 100 square feet. The sheet shall be lightly broomed as It 1s applied. Apply Malarkey Premium Cap Sheet surfacing parallel to the underlying roofing and lapped so the flow of water is over the laps. The sheets shall be cut into 12' lengths and allowed to flatten before application. The underlying roofing shall be mopped with hot asphalt at the rate of 25 lbs. per 100 square feet. Malarkey Premium Cap shall be neatly set in place providing a 2" side lap and 4" end laps. Adjacent end laps shall be at least 3' apart. Malarkey recommends the use of its SBS Polyester Cap Sheet as a base flashing material. RECEIVED CITY OF TUKWILA OCT 9 1986 BUILDING DEPT. 223.01•PA•CI•FR•R248LC PACIFIC RAINIER ROOFING, INC. PHONE 367.2525 10735 STONE AVE. NORTH MONTY D. MOORE SEATTLE, WASH. 98133 (ITY OF TUKMILA �. 6200 So th=_,PI"levard BU . DING PERMIT APPLIC�' TION Tukwlle, Washington 98188 Control # $4-Y-10 (206),423 -1845 Site Address 900 -916 I• . - Suite# _ Floor# _ Project Name /Tenant Koll Business Center Phase 4 Assessors Account# 95- 6465818 Valuation of Construction 26, 608.00 Property Owner Koll Business Center Seattle Address 2021 152nd Avenue N.E. Redmond, WA App l i cant The Koll Company Address 601 Strander Tukwila, WA Architect /Engineer none Address Phone 206/643 -1776 ZiP 98057 Phone 57R -0765 Zi p 98188 Phone Zip Contractorpacific Rainier Roofing, 'fTcense# PA- CI- FR- R248LC Phone 206/367 -2525 Address 10735 Stone Avenue North Seattle, WA Zip 98133 Class of Work: ❑ New ❑ Addition ❑ Tenant Improvement ❑ Remodel (residential) ® Reroof ❑ Demolition ❑ Interior Demolition ❑ Other Describe work to be done Reroofing Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building 19,200 s . f . Square footage of tenant spacenot available Building Use Office /Warehouse Will there be a change of use? ❑ Yes © No If yes, describe change of use, including square footages of changed areas Will there be storage or use of flammable, combustible or hazardous materials on the premise or area of construction? ❑ Yes El No If yes, explain I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND TIIAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK. Applicant /Authorized Agent (signature) 7g47. �'� -'�--- y (print name) Monty D. Moore 'Contact Person (please print) Monty D. Moore Date 9/22/86 Phone206 /367 -2525 OFFICE USE ONLY FEES: Building Permit Fee (000/322.100) $ 2(0 5,DC5 Receipt# Plan Check Fee (000/345.830) Receipt Bldg Code Sur Charge (000/386.904) 1.50 Receipt# Energy Sur Charge* (000/386.907) Receipt# Other ( ) Receipt# 9-_ Date Paid 112'61•0 Date Paid Date Paid Date Paid Date Paid *New construction only TOTAL SQUARE FOOTAGE /BUILDING USE INFORMATION FLOOR, USE /Occ Type SQ.FT. OGG .1.QAD USE /Occ Type (00,35V (OWES: $ _ uare Foot ae of Entirg Buildina: OCC SQ.FT. LOAD, USE /Occ Type. SQ.FT. OCC JUL. TOTAL SQ.FT. TOTAL OCC. TOTAL I TRACKING 1 • 1' 11 MEN S BLDG FIRE Approved for Issuance To Mahan: Date Approved: Approved (Initials) Per letter dated Fire Protection: O Sprinklers ❑Detectors Type of Const. PLNG Approved (Initials) ❑ BAR d LAND USE /SEPA CONDITIONS Zoning Setbacks: N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: PWD Approved (Initials) Per letter /plans dated