Loading...
HomeMy WebLinkAboutPermit 4493 - Koll Business Center - Koll 30 - ReroofCITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 BUILDING PERMIT PERMIT # (//t/q Control #86 -349 Work to be done Reroof Site Address1000 - 1016 Industry Dr Suite # Tenant Koll #30 Building Use Office /warehouse Assessors Account # 252304 -9071 Property Owner Koll Business Center Seattle Phone # 206/643 -1776 Address 2021 152nd Avenue N.E. Redmond, WA Zip 98052 Contractor Pacific Rainier Roofing, Inc. Phone #206/367 -2525 Address 10735 Stone Avenue North, Seattle, WA / _ , Zip 98133 r .,/ FOR BUILDING PERMIT ONLY Approved for issuance by S q • Ft. Office Storage/ e Ware hous Retail Other Occ. Load 1st F1. 2nd FT- '- 3rd F1. Total Fire Protection: [[ Sprinklers [] Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 22.400 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt #3802 $ 225.00 Receipt # $ Receipt # $ Receipt #3802 $ 1.50 Receipt # $ Receipt # $ $ 226.50 FOR SIGN PERMIT ONLY [1] Permanent [[Temporary Single Face [] Double Face (] Wall Mounted LJ Free Standing [[ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions 1HIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND OROINANCES GOVERNING THIS TYPE OF WORK WIL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE UR,(�g� PRO SIGNS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONDUCTION OR T/ PERFORMANCE OF CONSTRUCTION. 1/Signed___ < <11YY �) Date !! // / /// '_ 9�� LICENSED CONTRACTORS DECLARATION ) V I -'/ hereby affirm that I a 1 'Fn ed u der . ovisions of the Business and Professions Code, and my license is in full f r(S/4 /dd effect. 1 . _ Date 70 -- / 3 Y c/ Contractor (signature) OWNER- BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) 1, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature) Date CITY OF TUKWILA Building Division ,6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 BUILDING PERMIT PERMIT # L ✓ Control #86 -349 Work to be done Reroof Site Address1000 - 1U16 Industry ter Suite # Tenant Koll #30 Building Use Office /warehouse Assessors Account # 252304 -9071 Property Owner Koll Business Center Seattle Phone # 206/643-1776 Address 2021 152nd Avenue N.E. Redmond, WA Zip 98062 Contractor Pacific Rainier Roofing, Inc. Phone #206/367 -2525 Address 10735 Stone Avenue North, Seattle, WA %) Zip 98133 FOR BUILDING PERMIT ONLY Approved for issuance by !, %� J Sq. Ft. 1st F1. 2nd Fl. `3rd Fl. Office Storage/ Warehouse Retail Other Occ. Load Total Fire Protection: E] Sprinklers [] Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 22,400 Bldg. Permit Fee Receipt #3802 $ 225.00 Plan Check Fee Receipt # $ Demolition Receipt # $ Surcharges Receipt #3802 $ 1.50 Other Receipt # $ Other Receipt # $ TOTAL $ 226.50 FOR SIGN PERMIT ONLY El Permanent E] Temporary [[ Single Face 0 Double Face E] Wall Mounted El Free Standing E] Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Special Conditions Total square footage of sign ■ THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT, ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DUES NOT PRESUME TO GIVE AUTHORITY TO 1/ VIOLATE OR QA��� PRO SI�ONLS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION " OR THE gORMANCE OF CONSTRUCTION. DD(( LICENSED CONTRACTORS DECLARATION vl hereby affirm that 1 am / nled u dery provisions of the Business and Professions Code, and my license is in full / f�jr` as d effect. Contractor (signature)U(,,r{ j �If �t Date %� J "` / 7 1CJ (� OWNER- BUILDER DECLARATION ( 1 1, as owner of the property. or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) I, as owner of the property, am exclusively contracting with licensedlcontractor's to construct the project. Owner (signature) Date CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206), 433 -1849 INSPECT 9,N RECORD 93 PERMIT # Date Type of Inspection /r /hd/ (-ei-.ocr) Date Wanted a.m. p.m. Site Address /000 o —/O/6 _Tile/e'sZ fy JG-, Project Requestor Phone # Special Instructions Inspection Results /Comments: Inspector —7 Date /e /a /17 Yy, PACIFIC RAINIER ROOFING, INC. 10735 Stone Avenue North Seattle, Washington 98133 -8996 Phone (206) 367 -2525 223- 01 -PA -C I- FR- R248LC September 29,19$7 FORM LETTER City of Tukwila 6200 Southcenter Blvd. Tukwila, WA 9$18$ Attention: Building Dept. Reference: Building Permit #4493 Subject: Notice of Completion Gentlemen: Pacific Rainier Roofing, Inc. has installed a roof membrane as- sembly consisting of a Tamko Spec #1314 (data sheet enclosed), which meets the requirements for Class A or Class B roofs. This roof was installed for Koll Business Center at Building" #30 1000- 1016 Industry Dr. Tukwila, WA 9$1$$ under Building Permit #141493. Please notify this office of your final inspection and acceptance. If we may be of further assistance, please advise. DKU /rsh Enclosures Sincerely, PACIFIC RAINIER ROOFING, INC. D. K. Unrue — an equal opportunity employer PACIFIC RAINIER ROOFING, INC. 10735 Stone Avenue North Seattle, Washington 98133 -8996 Phone (206) 367 -2525 223- 01- PA- CI- FR- R248LC City of Tukwila 6200 Southcenter Blvd.. Tukwila, WA 981$$ Attention: Building Dept. Reference: Building Permit #4493 Subject: Notice of Completion Gentlemen: September 29,19$7. FORM LETTER Pacific Rainier Roofing, Inc. has installed a roof membrane as- sembly consisting of a Tamko Spec #134 (data sheet enclosed), which meets the requirements for Class A or Class B roofs. This roof was installed for Koll Business Center at Building 130 1000- 1016 Industry Dr. Tukwila, WA 9$1$$ under Building Permit #44.93. Please notify this office of your final inspection and acceptance. If we may be of further assistance, please advise. Sincerely, PACIFIC RAINIER ROOFING, INC:.. D. K. Unrue DKU /rsh Enclosures an equal opportunity employer - CITY OF TUKWILA '. Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 BUILDING PERMIT PERMIT /( Control #36 -24 9 Work to be done - ."':07. Site Address - .- triau:JT .,. Suite U Tenant Kc;,l !,:,;) Building Use _ff1, -,/ ,,.•,a,r,,;,, Assessors Account # ::..7l Property Owner AI .. .1. ~_,• ..eat'ic Phone # . / •ii7S Address ... 1 -,/,,I •_. ,.- .:.,rc,r,(:. Zip Contractor ac or ;'`:'_'T 1,- ;r • ;m:.;. r :(a� `1 1�,, Inc. Phone #2.J;:/-w-,!e: :, Address 1...: . .'.v :riu' :: j.) tii, .).•Itt1i�, .JA Zip i:.', FOR BUILDING PERMIT ONLY ,': :: ror issuance by Sq. Ft. Office Stareoraghoue/ s e W Retail OtherIOcc. Load 1st F1.- 2nd F1. 3rd F1. Total _ Fire Protection: [] Sprinklers [] Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ :'): Bldg. Permit Fee Receipt it ,,,, o.: $ . ? . 0 Plan Check Fee Receipt # $ Demolition Receipt # $ Surcharges Receipt #if i2 $ 1.;:0 Other Receipt # $ Other Receipt # $ TOTAL $ 226.50 FOR SIGN PERMIT ONLY O Permanent [] Temporary O Single Face [] Double Face DI Wall Mounted [] Free Standing 0 Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR ICA$CEL THE. PROV•jSIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. _f .) ) y •f Signed L . f +', Date /'( J , 1 LICENSED CONTRACTORS DECLARATION I hereby affirm that I am,litensed wider provisions of the Business and Professions Code, and my license is in full force, apd effect. Date / - /, r 7 Contractor (signature) L OWNER - BUILDER DECLARATION ( ) 1, as owner of the property. or my employees, with wages as their sole coopensation, will do the work, and the structure is not intended or offered for sale. ) 1, as owner of the property, am exclusively contracting with licensed;contractor's to construct the project. Owner (signature) Date c TYPE III STEEP ASPHALT TAMKO VAPOR•CHAN VENTING BASE SHEET AWPLAN 170 GRANULE SURFACED SPOT MOP ON 12-.24' CENTERS WITH TYPE III, STEEP ASPHALT XISTING GRAVEL SURFACED MEMBRANE NO PRIME)AVEL 12.0 TAMKO RE- ROOFING SYSTEMS 12.1 RI-ROOFING OVER EXISTING GRAVEL SURFACED MEMBRANE (ASPHALTIC COMPOSITION) Specification 131 (Regular)/131 HW (Heat Welding/231 (AWAPLAN 170) 12.1.1 Slope Positive drainage up to 12.1.2 Material Requirements TAMKO VAPOR -CHAN Fiberglass Venting Base Sheet TAMKO AWAPLAN REGULAR or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt As specified Concrete Primer Approx. 3/4 Gal. 12.1.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM D- 312 -84, Type III. (See Section 6.6 for more details.) 12.1.4 Preparation: Broom the membrane surface and remove all of the loose roofing gravel and debris. Make random cuts or breaks in the old membrane 4 ft. o.c. to allow vapor pressure to vent. All wet or deteriorated insulation or membrane must be removed and replaced prior to the application of new roofing mate- rials. The surface should be primed with TAMKO Concrete Primer at a rate of approxi- mately 3/4 gal. per 100 sq. ft. prior to the application of new roofing materials. 12.1.5 TAMKO VAPOR -CHAN: Over the old mem- brane and starting at the low point of the roof, install one ply of TAMKO VAPOR -CHAN base sheet. The VAPOR -CHAN should be side lapped 2 in., and end lapped 4 in. The base ply should be secured to the old membrane with spots of Type III, Steep Asphalt spaced on (not to exceed) 24 in. centers. 12.1.6 AWAPLAN Regular or AWAPLAN 170: Starting at the low point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in. The AWAPLAN or AWAPLAN 170 should be solidly adhered. to the base ply (pressed into the hot asphalt) with approximately 30 lbs. ( 15%) of speci- fication asphalt. 12.1.7 AWAPLAN Heat Welding: Starting at the low point of the roof, Install one ply of TAMKO welding grade AWAPLAN, side lapped 4 in., and end lapped 6 in. The AWAPLAN should be solidly adhered to the base ply by heating the back -side with a torch at the junc- ture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.1.8 Flashing: The flashing material must be granule surfaced TAMKO AWAPLAN, AWAPLAN 170 or VERSA -FLASH 160. (See Sections 6.9 and 13.0 for more details.) 12.1.9 Venting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. 11/2 in. per lineal ft. Per 100 Sq. Ft. 1 Ply TYPE III STEEP ASPHALT TAMKO VAPOR•CHAN VENTING BASE SHEET SPOT MOP ON 17..24' CENTERS WITH TYPE 111, STEEP ASPHALT AWAPLAN/ AVWPLAN 170 GRANULE SURFACED EXISTING GRAVEL SURFACED MEMBRANE DO NOT PRIME)L — 12.2 RE- ROOFING OVER EXISTING GRAVEL SURFACED MEMBRANE (COAL -TAR PITCH) Specification 132 (Regular) /132 HW (Heat Welding/ 232 ( AWAPLAN 170) 12.2.1 Slope Up to 1/4 in. per lineal ft. 12.2.2 Material Per Requirements 100 Sq. Ft. TAMKO VAPOR -CHAN Fiberglass Venting Base Sheet 1 Ply TAMKO AWAPLAN REGULAR or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt As specified 12.2.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM D-312-84, Type III. (See Section 6,6 for more details.) 12.2.4 Preparation: Broom the membrane surface and remove all of the loose roofing gravel and debris. Make random cuts or breaks in the old membrane 4 ft. o.c. to allow vapor pressure to vent from the old system and any existing insulation materials. All wet or deteriorated insulation or membrane must be removed and replaced prior to the application of new roof- ing materials. DO NOT USE ANY PRIMERS. 12.2.5 TAMKO VAPOR -CHAN: Over the old mem- brane and starting at the low point of the roof, install one ply of TAMKO VAPOR -CHAN base sheet. The VAPOR -CHAN should be side lapped 2 in. and end lapped 4 in. The base ply should be secured to the old membrane with spots of Type III, Steep Asphalt spaced on (not to exceed) 24 in. centers. 12.2.6 AWAPLAN Regular or AWAPLAN 170: Starting at the fow point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in, The AWAPLAN or AWAPLAN 170 should be solidly adhered to the base ply (pressed into the hot asphalt) with approximately 30 lbs. (± 15 %) of speci- fication asphalt. 12.2.7 AWAPLAN Heat Welding: Starting at the low point of the roof, Install one ply of TAMKO e welding grade nd lapped 6Ain.. Theside AWAlapped LAAN should be solidly adhered to the base ply by heating the backside with a torch at the junc- ture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.2.8 Flashing: The flashing material must be granule surfaced TAMKO AWAPLAN, AWAPLAN 170 or VERSA -FLASH 160. (See Sections 6.9 and 13.0 for more details.) 12.2.9 Wnting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. 07500/TAM Buyline 3120 AV APLAW AVWPLAN 170 GRANULE SURFACED TYPE III STEEP ASPHALT TAMKO VENTPLY PUNCHED FIBERGLASS BASE SHEET EXISTING SMOOTH SURFACED MEMBRANE (PRIMED) 12.3 RE- ROOFING OVER EXISTING INORGANIC SMOOTH SURFACED MEMBRANE —_Specification 134 234 ( AWA PLAN 170j eat Welding)/ 12.3.1 Slope Up to 3 in. per lineal ft. 12.3.2 Material Per Requirements 100 Sq. Ft. TAMKO VENT -PLY Punched Fiberglass Base Sheet 1 Ply TAMKO AWAPLAN REGULAR or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt Approx. 30 lbs. Concrete Primer Approx. 3/4 gal. 12.3.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM D- 312 -.)84, Type 111. (See Section 6.6 for more 12.3.4 Preparation: Clean and prime the entire sur- face with 44 gal. of TAMKO Concrete Primer per 100 sq. ft, All wet or deteriorated insulation must be removed and replaced ,prior to the application of new roofing materials. 12.3.5 TAMKO VENTPLY: Over the old membrane and starting at the low point of the roof, install one ply of TAMKO VENT-PLY Punched Fiberglass Base Sheet. Install the VENT-PLY by rolling out the sheet dry over the roof membrane, sprinkle mop to hold the sheet in place until the final course is installed. Side laps shall be 2 in. and end laps 4 in. 12.3.6 AWAPLAN Regular or AWAPLAN 170: Starting at the low point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in. The AWAPLAN or AWAPLAN 170 should be solidly adhered to the base ply (pressed into the hot asphalt) with approxi- mately 30 lbs. (t 15%) of specification asphalt. 12.3.7 AWAPLAN Heat Welding: Starting at the low point of the roof, install one ply of TAMKO welding grade AWAPLAN, side lapped 4 in., and end lapped 6 in. The AWAPLAN should be solidly adhered to the base ply by heating the back -side with a torch at the juncture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.3.8 Flashing: The flashing material must be granule surfaced TAMKO AWAPLAN, AWAPLAN 170 or VERSA -FLASH 160. (See Sections 6.9 and 13.0 for more details.) 12.3.9 Venting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. 25 TAM KO A I P M. 1 1 . 1 O.. t 1 ,. I M t. .r M: ++,+G.KiiIY`w ✓.:.vC ::3."sWO4,14.'}i.1l.b:'.i Witgega l Mr. Monty Moore Pacific Rainier Roofing, Inc. 10735 Stone Avenue North Seattle, WA 98133 C October 7. 1986 SUBJECT: U.L. APPROVAL TAMKO ROOFING SYSTEMS #134 & #i234 Dear Mr. Moore: P. O. Sox 1404 601 NORTH HIGH ST. AREA CODE 14171 624.6644 JOPLIN. MISSOURI 64002 Please be advised that Tamko's Recover Specifications #134 and #234 are approved by U.L. as A, B or C when installed in compliance with the 1986 Building Materials Directory. The reference card is R3225 (N Item 5). The new card listing will allow the use of Vent -Ply or Vapor -Chan as the base ply. The surfacing options of fibered aluminum or emulsion will not change. If local code authorities require more information, they can call U.L. at 312 -272 -8800. vn cc: W. Kent Blanchard John Kirby Sincerely, leL" Cik tee....„) Richard McReynolds Western Regional Manager Macdona' acLaren Associat e Ctnc Consulting Engineers �± October 3, .1986 Mr. Charles E. Scofield Koll Company 601 Strander Boulevard Tukwila, WA 98188 RE: Koll Business Center Additional Roofing Loans Dear Mr. Scofield, We have examined the structural drawings and have determined that the following buildings are capable of a 1.65 additional . roof load: Building'22, 26,30, 31, 36 and 42 (.6 buildings).. i:73.141-4-1--271C/JU/it—its71) tom) D. Bruce McLaren, P.E. DBM/cmh T YV .O x-134 BAse v €A4 PLy AWA RA- N r7 0 PisP w )}1,7- a Nevi J Macdonald 215 Eighth Avenue North 0. Bruce %I :Laren James C. Peterson Sea:tie WA 98109 206.E22.45*.� City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433 -1800 Gary 1. VanDusen, Mayor September 14, 1987 Pacific Rainier Roofing 10735 Stone Ave. N. Seattle, WA 98133 Attn: Monty Moore Re: Building Permits #4490, #4491, #4492, #4493, #4494, #4495 and #4496 Koll Buildings #22, #26, #28, #30, #31, #36, and #42 (reroof) Dear Mr. Moore: Our records indicate that these permits have not been finalled by the Building Division. In order for us to sign -off on this project we need you to provide us with a written statement regarding compliance with the Uniform Building Code (1985 Edition) roof covering requirements. The attached handout provides you with an example statement. Please provide this information within 15 days of receipt of this letter or contact us with the status of this project. If you should have any questions, please contact me at 433 -1852. Sincerely, /;1',-, --? Norm Bray Building Inspector ip Lo G,e. ►y1 CA.,Qc 1 uy 11 by nil it e P' ? CLuti ��Q,c ti c E • ; ,•• ", • • • • "I. • • • • • ••• • MacdonaIdLLaren Associate .11c • Consulting Engineers October 3, 1986 Mr. Charles E. Scofield Koll Company 601 Strander Boulevard Tukwila, WA 98188 RE: Koll Business Center Additional Roofing Loans Dear Mr. Scofield, We have examined the structural drawings and have determined that the following buildings are capable of a 1.65 additional roof load: Building 22, 26,30, 31, 36 and 42 (6 buildings). Sincerely, ,g1.4a4:271C D. Bruce McLaren, P.E. DBM/cmh RECEIVED CITY OF ruicwILA OCT 9 1986 BUILDING Der. Neil J. Macdonald D. Bruce McLaren James C. Peterson ' 215 Eighth Avenue North - Seattle, WA 98109 206.622.4580 Malarkey BUILT -UP ROOFING SPECIFICATIONS NM3 NAILABLE DECK MINERAL SURFACED FIBERGLASS FIBERGLASS PREMIUM 1 SBS BASE SHEET PREMIUM 1 PLY SHEET NAILABLE DECK 12" o 2" b91 0 0 0 0 0 0 0 O O 0 0 0 0 18" 0 12 „. t O o 0 O 0 0 0 0 0 • 1W ft t 34" ROOFING ASPHALT ZON U.L. CLA�.�S+S► "A" — Up to 2") "C" — 271-1-0-1)" Materials Per 100 Square Feet 1.4 Premium 1 SBS Base Sheet 1 ply 30 lbs. Premium 1 Ply Sheet 1 ply 11 Ibs. Premium Cap Sheet 1 ply 75 Ibs. Asphalt between Plies 50 Ibs. General requirements are applicable as part of this specification. APPLICATION: Over wood boards only, lay one ply of rosin sheath- ing paper. Lap each sheet at least 2” and nail suffi- ciently to hold in place. Apply Malarkey Premium 1 SBS Base Sheet so flow of water is over or parallel to the laps. Lap each sheet 2" on sides and 6" on ends. Nail each sheet 9" on center through the laps and 18" on center along line 12" distance from each edge. Turn up 2" above cant at all vertical surfaces. Apply Malarkey Premium 1 Ply Sheet parallel to the base sheet and lap so water !low is over not against laps. All end laps shall be 4" and adjacent FIBERGLASS PREMIUM CAP SHEET end laps shall be 12" apart. The full width of each sheet shall be embedded in hot asphalt at the rate of 25 lbs, per 100 square feet. The sheet shall be lightly broomed as it is applied. Apply Malarkey Premium Cap Sheet surfacing parallel to the underlying roofing and lapped so the flow of water is over the laps. The sheets shall be cut into 12' lengths and allowed to flatten before application. The underlying roofing shall be mopped with hot asphalt at the rate of 25 Ibs. per 100 square feet. Malarkey Premium Cap shall be neatly set in place providing a 2" side lap and 4" end laps. Adjacent end laps shall be at least 3' apart. Malarkey recommends the use of its SBS Polyester Cap Sheet as a base flashing material. RECEIVED CITY OF TUKwiLA OCT 9 '1986 BUILDING CITY OF TUKWILA Building Division BUS`` DING PERMIT APPLIC TION 6200 Sothcenter Boulevard Tukwila, Washington 98188 Control # .3/iq (206) 433 -1845 +r Site Address 1000 -1016 Industry Drive Bldg. #30 Project Name /Tenant Koll Business Center Phase 5 Valuation of Construction 22,400.00 Assessors Account# Property Owner Koll Business Center Seattle Address 2021 152nd Avenue N.E. Redmond, WA Applicant The Koll Company Suite# Floor# 95- 6465818 Phone 206/643 -1776 Zip 98052 Phone 575 -0765 Address 2021 Strander Tukwila, WA Architect /Engineer none Phone Address ContractorPacific Rainier Roofing, 'License# PA— CI— FR— R248LC Address 10735 Stone Avenue North Seattle, WA Class of Work: ❑ New ❑ Addition ❑ Tenant Improvement ❑ Remodel (residential ❑ Demolition ❑ Interior Demolition ❑ Other Describe work to be done Zip 98188 Zip Phone206 /367 -2525 Zip 98133 Reroofing Reroof Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building 15,600 s . f . Square footage of tenant space Building Use Office /warehouse Will there be a change of use? ❑ Yes No If yes, describe change of use, including square footages of changed areas Will there be storage or use of flammable, combustible or hazardous materials on the premise or area of construction? ❑ Yes Q No If yes, explain I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK. Applicant /Authorized Agent (signature) (print name) MnnFy D. Moore Contact Person (please print) Monty D. Moore Date 9/22/86 Phone 206/367 -2525 I OFFICE USE ONLY FEES: Building Permit Fee (000/322.100) $ Plan Check Fee (000/345.830) Bldg Code Sur Charge (000/386.904) Energy Sur Charge* (000/386.907) Other ( ) *New construction only o?.` .00 Receipt# Receipt# 1.50 Receipt# Receipt# Receipt# Date Paid Date Paid Date Paid Date Paid Date Paid OY 4 5fi TOTAL 2 k2 (OWES: $ SQUARE FOOTAGE /BUILDING USE INFORMATION FLOOR USE /Occ Type SQ.FT. ULU ,LOAD USE /Occ Type S Square Footp qe of Entir- Buildinq: OCC Q.F1'. LOAD. USE /Occ Typ= SQ.FT. OCC TOTAL SQ.FT. TOTAL OCC. TOTAL TRACKING DEPT. DATE TN DATE OUT1 COMMENTS BLDG Approved for Issuance ci0 10.\01u To Mahan: Date Approved: FIRE Approved (Initials) Per letter date Fire Protection: 0 Sprinklers ❑ Detectors Type of Const. PLNG Approved (Initials) D BAR ❑ LAND USE /SEPA CONDITIONS Zoning Setbacks: N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: PWD Approved (Initials) Per letter /plans dated