HomeMy WebLinkAboutPermit 4494 - Aetna - Koll 31 - ReroofCITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 BUILDING PERMIT PERMIT # v/ti q Control # 86 -350 Work to be done Reroof Site Address 965 - 981 Industry Dr Suite # Tenantkoll f31 Building Use Office /warehouse Assessors Account # 252304 -9034 Property Owner Aetna Phone # 203/275 -2395 Address one Civic Center P1 4a. Hartford, Connecticut Zip 06143 Contractor Pacific Rainier Roofing, -Inc. #PA- CI- FR- R248LC Phone #206/3b/ -2b2b Address 10735 Stone Avenue North Seattle, WA n Zip 98133 FOR BUILDING PERMIT ONLY Approved fro issuance by S Ft. Sq. Office Storage/ Warehouse Retail Other Occ. Load 1st F1. 2nd FTC 3rd Fl. Total Fire Protection: [] Sprinklers Q Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 24,069 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt #3802 $ 243.00 Receipt # $ Receipt # $ Receipt #3802 $ 1.50 Receipt # $ Receipt # $ $ 244.50 FOR SIGN PERMIT ONLY El Permanent (J Temporary [J Single Face [] Double Face J] Wall Mounted J] Free Standing [J Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Special Conditions Total square footage of sign THIS PERMIT BECUMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK 15 SUSPENDED OR ABANDONED FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE 0 AN EL HE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONST UUJON OR THE P FORMANCE OF CONSTRUCTION. V, Signed_ Date —13 LICENSED CONTRACTORS DECLARATION ns d u•er p .visions of the Business and Professions Code, and m license is in full,fpr e and effect. Date U f 3 " ' (GAO? I/ I hereby affirm that I aml "`-Contractor (signature) Li OWNER- BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( 1 1, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature) Date CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done Reroof Site Address 965 - 981 Industry Dr Building Use Office /warehouse Property Owner Aetna Address ona Civir Centpr Pl4za, Hartford, Connecticut Contractor Pacific Rainier Rooting, Inc. #PA -CI } R- R248LC Address 10735 Stone Avenue North Seattle, WA BUILDING PERMIT Suite # Assessors PERMIT # CI`/C76/ Control # 86 -350 TenantKoll 1131 Account # 252304 -9034 Phone # 203/2/5-2395 Zip 06143 Phone #206[Jb /- n Zb Zip 98133 FOR BUILDING PERMIT ONLY Approved fro issuance by /` S /,.D_W-1LOf% it;_ Sq. Warehouse e Retail Other Occ. Load 1st F1. 2nd FT:- 3rd .F1. Total Fire Protection: C1 Sprinklers 1 Detectors Zoning Type of Construction Special Conditions Y. Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 24,069 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other Receipt #3802 $ 243.00 Receipt # $ Receipt # $ Receipt #3802 $ 1.50 Receipt # $ Receipt # $ TOTAL $ 244.50 FUR SIGN PERMIT ONLY Q Permanent [( Temporary 1 Single Face [[ Double Face [] Wall Mounted [] Free Standing [] Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DUES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE 07 //{N EL HE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUC ON OR_ THE P FORMANCE OF CONSTRUCTION. Signed_ � Date /6/ . / ��' I hereby affirm that I am/jl . n Contractor (signature) ( ) 1, as owner offered for ( 1 I, as owner Owner (signature) LICENSED CONTRACTORS DECLARATION visions of the Business and Professions Code, and my License is in full �r e and effect. Date /0—re? "_"/ / V OWNER- BUILDER DECLARATION of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or sale. of the property, am exclusively contracting with licensed contractor's to construct the project. Date CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1849 INSPECT ON RECORD PERMIT # i>919 Date Type of Inspection /1-//'!d/ (,.e#orJ Date Wanted a.m. p.m. Site Address 965- 9s7( ..,T-hcwst'y LTi/ -, Project Requestor Phone # Special Instructions Inspection Results /Comments: Inspector Date /0/77 PACIFIC RAINIER ROOFING, INC. 10735 Stone Avenue North Seattle, Washington 98133 -8996 Phone (206) 367 -2525 223- 01 -PA -C I- FR- R248LC September 29, 19$7 FORM LETTER City of Tukwila 6200 Southcenter Blvd. .Tukwila, WA 9$1$$ Attention: Building Dept. Reference: Building Permit #4494 Subject: Notice of Completion Gentlemen: Pacific Rainier Roofing, Inc. has installed a roof membrane as- sembly consisting of a Tamko Spec #134 (data sheet enclosed), which meets the requirements for Class A or Class B roofs. This roof was installed for Koll Business Center at Building #31 965- 9$1 Industry Dr. Tukwila, WA 98188 under Building Permit #4494. Please notify this office of your final inspection and acceptance. If we may be of further assistance, please advise. DKU /rsh Enclosures Sincerely, PACIFIC RAINIER ROOFING, INC.. D.K. Unrue an equal opportunity employer -- •1,• c; PACIFIC RAINIER ROOFING,- INC. 10735 Stone Avenue North Seattle, Washington 98133 -8996 Phone (206) 367 -2525 223- 01- PA- CI- FR- R248LC September 29, 19$7 FORM LETTER City of Tukwila 6200 Southcenter Blvd. Tukwila, WA 9$18$ Attention: Building Dept. Reference: Building Permit #4494 Subject: Notice of Completion Gentlemen: Pacific Rainier Roofing, Inc. has installed a roof membrane as- sembly consisting of a Tamko Spec #134 (data sheet enclosed), which meets the requirements for. Class A or Class B roofs. This roof was installed for Koll Business Center at Building #31 965- 9$1 Industry Dr. Tukwila, WA 9$1$$ under Building Permit #4494. Please notify this office of your final inspection and acceptance. If we may be of further assistance, please advise. Sincerely, PACIFIC RAINIER ROOFING, INC. D.K. Unrue DKU /rsh Enclosures — an equal opportunity employer- CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done •. ilroof Site Address - .1.A I+ldustr'' Building Use ,i;.i; ;,;'rarehousc Property Owner ;,;.,,y,0 Address Contractor Address BUILDING PERMIT PERMIT # Control # Suite # Tenant(— ,1 -L Assessors Account # .::;e2Q4 -JO34 Phone # ` _` 1. . �J� �i�(•,n "z it�''.'r11J r� .��.�r•�'fl ., ,,1V I�:, JA Zip 614 Phone #= /:` 1 FOR BUILDING PERMIT ONLY ;prr)ved `r•o i ss•aar(:? by l • Zip jcJ3 S q • Ft. Office Storhges Warehouse Retail Other Occ. Load 1st F1. 2nd Fl. 3rd F1. Total Fire Protection: E] Sprinklers [] Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st Fl. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ L4, _.>; Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt #3CO2 $ 243.3, Receipt # $ Receipt # $ Receipt #3L02 $ Receipt # $ Receipt # $ $ FUR SIGN PERMIT ONLY 0 Permanent 0 Temporary 0 Single Face 0 Double Face J Wall Mounted (] Free Standing [] Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECOMES NULL AND V0I0 IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TINE AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS ANO ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TU GIVE AUTHORITY TO VIOLATE OR- GANCEL THE .PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. Signed__ ' �i tf,y, .1 i Date /� ' _ - f %)i� LICENSED CONTRACTORS DECLARATION I hereby affirm that I am lfceansed u der provisions of the Business and Professions Code, and my License Is in full fo >(e and effect. Contractor (signature) r ;y {.. ( •r Date l '! OWNER - BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature) Date TYPE 111 STEEP ASPHALT TAMKO VAPOR•CHAN VENTING BASE SHEET SPOT MOP ON 12-.24- CENTERS WITH TYPE 111, STEEP ASPHALT A ' LAW AVMPLAN 170 GRANULE SURFACED XISTING GRAVEL SURFACED MEMBRANE (BROOM GRAVEL AND PRIME) 12.0 TAMKO RE- ROOFING SYSTEMS 12.1 RE- ROOFING OVER EXISTING GRAVEL SURFACED MEMBRANE (ASPHALTIC COMPOSITION) Specification 131 (Regular)/131 HW (Heat Welding/231 (AWAPLAN 170) 12.1.1 Slope Positive drainage up to 11/2 in. per lineal ft. 12.1.2 Material Per Requirements 100 Sq. Ft. TAMKO VAPOR -CHAN Fiberglass Venting Base Sheet 1 Ply TAMKO AWAPLAN REGULAR Or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt As specified Concrete Primer Approx. 3/4 Gal. 12.1.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM D- 312 -84, Type III. (See Section 6.6 for more details.) 12.1.4 Preparation: Broom the membrane surface and remove all of the loose roofing gravel and debris. Make random cuts or breaks in the old membrane 4 ft. o.c. to allow vapor pressure to vent. All wet or deteriorated insulation or membrane must be removed and replaced prior to the application of new roofing mate- rials, The surface should be primed with TAMKO Concrete Primer at a rate of approxi- mately 3/4 gal. per 100 sq. ft. prior to the application of new roofing materials. 12.1.5 TAMKO VAPOR -CHAN: Over the old mem- brane and starting at the low point of the roof, install one ply of TAMKO VAPOR -CHAN base sheet. The VAPOR -CHAN should be side lapped 2 in., and end lapped 4 in. The base ply should be secured to the old membrane with spots of Type III, Steep Asphalt spaced on (not to exceed) 24 in. centers. 12.1.6 AWAPLAN Regular or AWAPLAN 170: Starting at the low point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in. The AWAPLAN or AWAPLAN 170 should be solidly adhered to the base ply (pressed into the hot asphalt) with approximately 30 lbs. (t 15%) of speci- fication asphalt. 12.1.7 AWAPLAN Heat Welding: Starting at the low point of the roof, install one ply of TAMKO welding grade AWAPLAN, side lapped 4 in., and end lapped 6 in. The AWAPLAN should be solidly adhered to the base ply by heating the back -side with a torch at the junc- ture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.1.8 Flashing: The flashing material must be AWAPLAN surfaced d AWAPLAN, VERSA -FLASH 160. (See WAP 170 or Sections 6.9 and 13.0 for more details.) 12.1.9 Venting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. TYPE III STEEP ASPHALT TAMKO VAPOR•CHAN VENTING BASE SHEET AWAPLAN/ AWAPLAN 170 GRANULE SURFACED SPOT MOP ON 12.24' CENTERS WITH TYPE III, STEEP ASPHALT EXISTING GRAVEL SURFACED MEMBRANE DBROOM GRAVEL. — O NOT PRIME) 12.2 RE- ROOFING OVER EXISTING GRAVEL SURFACED MEMBRANE (COAL -TAR PITCH) Specification 132 (Regular)/132 HW (Heat Welding/ 232 ( AWAPLAN 170) 12.2.1 Slope Up to '/, in. per lineal ft. 12.2.2 Material Per Requirements 100 Sq. Ft. TAMKO VAPOR -CHAN • Fiberglass Venting Base Sheet 1 Ply TAMKO AWAPLAN REGULAR or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt As specified 12.2.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM D- 312.84, Type III. (See Section 6.6 for more details.) 12.2.4 Preparation: Broom the membrane surface and remove all of the loose roofing gravel and debris. Make random cuts or breaks in the old membrane 4 ft. o.c. to allow vapor pressure to vent from the old system and any existing insulation materials. All wet or deteriorated insulation or membrane roust be removed and replaced prior to the application of new roof- ing materials. DO NOT USE ANY PRIMERS. 12.2.5 TAMKO VAPOR -CHAN: Over the old mem- brane and starting at the low point of the roof, install one ply of TAMKO VAPOR -CHAN base sheet. The VAPOR -CHAN should be side lapped 2 in. and end lapped 4 in. The base ply should be secured to the old membrane with spots of Type III, Steep Asphalt spaced on (not to exceed) 24 in, centers, 12.2.6 AWAPLAN Regular or AVMAPLAN 170: Starting at the row point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in. The AWAPLAN or AWAPLAN 170 should be solidly adhered to the base ply (pressed into the hot asphalt) with approximately 30 lbs. ( ±15%) of speci- fication asphalt. 12.2.7 AWAPLAN Heat Welding: Starting at the low point of the roof, Install one ply of TAMKO welding grade AWAPLAN, side lapped 4 in., and end lapped 6 in. The AWAPLAN should be solidly adhered to the base ply by heating the backside with a torch at the junc- ture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.2.8 Flashing: The flashing material must be granule surfaced TAMKO AWAPLAN, AWAPLAN 170 or VERSA -FLASH 160. (See Sections 6.9 and 13.0 for more details.) 12.2.9 Venting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. 07500/TAM Buyline 3120 AWAPLAN/ AWAPLAN 170 GRANULE SURFACED TYPE 111 STEEP ASPHALT TAMKO VENTPLY PUNCHED FIBERGLASS BASE SHEET EXISTING SMOOTH SURFACED MEMBRANE (PRIMED) 12.3 RE- ROOFING OVER EXISTING INORGANIC SMOOTH SURFACED. MEMBRANE — Specification 134 (Regular) /134 HW (Heat Welding)/ 234 (AWAPLAN 170) 12.3.1 Slope Up to 3 in. per lineal h. 12.3.2 Material Per Requirements 100 Sq. Ft. TAMKO VENT -PLY Punched Fiberglass Base Sheet 1 Ply TAMKO AWAPLAN REGULAR or AWAPLAN 170 AWAPLAN Heat Welding Grade (Granule Surfaced) 1 Ply Asphalt Approx. 30 lbs. Concrete Primer Approx. 3/4 gal. 12.3.3 Specification Asphalt: The asphalt shall be certified by the manufacturer to meet ASTM 0-312-84, type III. (See Section 6.6 for more details.) 12.3.4 Preparation: Clean and prime the entire sur- face with 3/4 gal. of TAMKO Concrete Primer per 100 sq. ft. All wet or deteriorated insulation must be removed and replaced .prior to the application of new roofing materials. 12.3.5 TAMKO VENTPLY: Over the old membrane and starting at the low point of the roof, install one ply of TAMKO VENT-PLY Punched Fiberglass Base Sheet. Install the VENT-PLY by rolling out the sheet dry over the roof membrane, sprinkle mop to hold the sheet in place until the final course is installed. Side laps shall be 2 in. and end laps 4 in. 12.3.6 AWAPLAN Regular or AWAPLAN 170: Starting at the low point of the roof, install one ply of TAMKO AWAPLAN or AWAPLAN 170 granule surfaced sheet, side lapped 4 in., and end lapped 6 in. The AWAPLAN or AWAPLAN 170 should be solidly adhered to the base ply (pressed into the hot asphalt) with approxi- mately 30 lbs. (± 15%) of specification asphalt. 12.3.7 AWAPLAN Heat Welding: Starting at the low point of the roof, install one ply of TAMKO welding grade AWAPLAN, side lapped 4 in., and end lapped 6 in. The AWAPLAN should be solidly adhered to the base ply by heating the back -side with a torch at the juncture of the base ply and the AWAPLAN roll sufficiently to form a bead of melted asphalt as the AWAPLAN is rolled out. 12.3.8 Flashing: The flashing material must be granule surfaced TAMKO AWAPLAN, AWAPLAN 170 or VERSA -FLASH 160. (See Sections 6.9 and 13.0 for more details.) 12.3.9 Venting: TAMKO approved roof vents should be placed at a minimum of one vent for each 10 squares of roof area. 25 t VAMKO A I• N A t t • 1 0.. C I ,. I N C. fi• I) AMMO u ft=6+1111 d,S Wirir'ifi b;Yl a''i ` October 7, 1986 Mr. Monty Moore Pacific Rainier Roofing, Inc. 10735 Stone Avenue North Seattle, WA 98133 SUBJECT: U.L. APPROVAL TAMKO ROOFING SYSTEMS #134 & #234 Dear Mr. Moore: P. O. BOX 1404 801 NORTH HIGH ST. AREA CODE 14171 624.4644 .JOPLIN. MISSOURI 64802 Please be advised that Tamko's Recover. Specifications #134 and #234 are approved by U.L. as A, B or C when installed in compliance with the 1986 Building Materials Directory. The reference card is R3225 (N Item 5). The new card listing will allow the use of Vent -Ply or Vapor -Chan as the base ply. The surfacing options of fibered aluminum or emulsion will not change. If local code authorities require more information, they can call U.L. at 312- 272 -8800. vn cc: W. Kent Blanchard John Kirby Sincerely, h Q 1 Richard McReynolds • Western Regional Manager Macdonald:,:°, acLaren Associat Consulting Engineers • October 3, 1986 Mr. Charles E. Scofield Koll Company 601 Strander Boulevard Tukwila, WA 98188 RE: Koll Business Center Additional Roofing Loans Dear Mr. Scofield, We have examined the structural drawings and have determined that the following buildings are capable of a 1.65 additional roof load: Building 22, 26,30, 31, 36 and 42 (6 buildings). Sincerely, D. Bruce McLaren, P.E. DBM /cmh. Neil J. Macdonald 2.15 Eighth avenue North TR rn ko * 134 I b /s4 VErUT PiY . 18'3 )4w9 PLAN ,70 ' ; S5, 4)sP N A CT" . 3 0 ►333 'b /sad- D. Bruce ^.claren., James C. Peterson•, Seattle 1VA 98109 266,622. »5c.6' City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433 -1800 Gary 1. VanDusen, Mayor September 14, 1987 Pacific Rainier Roofing 10735 Stone Ave. N. Seattle, WA 98133 Attn: Monty Moore Re: Building Permits #4490, #4491, #4492, #4493, #4494, #4495 and #4496 Koll Buildings #22, #26, #28, #30, #31, #36, and #42 (reroof) Dear Mr. Moore: Our records indicate that these permits have not been finalled:by the Building Division. In order for us to sign -off on this project we need you to provide us with a written statement regarding compliance with the Uniform Building Code (1985 Edition) roof covering requirements. The attached handout provides you with an example statement. Please provide this information within 15 days of receipt of this letter or contact us with the status of this project. If you should have any questions, please contact me at 433 -1852. Sincerely, Norm. Bray f � E . V►'l� ,.. Building Inspector P.(71' nbyYYl i - , e &CGUo N E Macdonald 1 •ALaren Associate .1 rc Consulting Engineers October 3, 1986 Mr. Charles E. Scofield Koll Company 601 Strander Boulevard Tukwila, WA 98188 RE: Koll Business Center Additional Roofing Loans Dear Mr. Scofield, We have examined the structural drawings and have determined that the following buildings are capable of a 1.65 additional roof load:. Building 22, 26,30, 31, 36 and 42 (6 buildings). Sincerely, D. Bruce McLaren, P.E. DBM /cmh RECEIVED CITY OF TUKWILA OCT 9 1986 BUILDING DEPT. Neil J. Macdonald 215 Eighth Avenue North D. Bruce McLaren : Seattle,lli/A 98109 BUILT-UP ROOFING SPECIFICATIONS NM3 NAILABLE DECK MINERAL SURFACED FIBERGLASS PREMIUM 1 SBS BASE SHEET FIBERGLASS PREMIUM 1 PLY SHEET NAILABLE DECK 0 0 0 0 12 "f o — 2" L-24 0 t 0 0 0 — 0 12" t O O i 0 0 0 0 0 0 0 o 0 O t 34" ROOFING ASPHALT ZONE 3 CLASS "A" — Up to �2" V.L.. VL tt^rr — 2' -6 V Materials Per 100 Square Feet Premium 1 SBS Base Sheet 1 ply 30 lbs. Premium 1 Ply Sheet 1 ply 11 lbs. Premium Cap Sheet 1 ply 75 lbs. Asphalt between Plies 50 lbs. General requirements are applicable as part of this specification. APPLICATION: Over wood boards only, lay one ply of rosin sheath- ing paper. Lap each sheet at least 2" and nail suffi- ciently to hold in place. Apply Malarkey Premium 1 SBS Base Sheet so flow of water is over or parallel to the laps. Lap each sheet 2" on sides and 6" on ends. Nail each sheet 9" on center through the laps and 18" on center along line 12" distance from each edge. Turn up 2" above cant at all vertical surfaces. Apply Malarkey Premium 1 Ply Sheet parallel to the base sheet and lap so water flow is over not against laps. All end laps shall be 4" and adjacent FIBERGLASS PREMIUM CAP SHEET end laps shall be 12" apart. The full width of each sheet shall be embedded In hot asphalt at the rate of 25 lbs. per 100 square feet. The sheet shall be lightly broomed as it is applied. Apply Malarkey Premium Cap Sheet surfacing parallel to the underlying roofing and lapped so the flow of water is over the laps. The sheets shall be cut into 12' lengths and allowed to flatten before application. The underlying roofing shall be mopped with hot asphalt at the rate of 25 lbs, per 100 square feet. Malarkey Premium Cap shall be neatly set in place providing a 2" side lap and 4" end laps. Adjacent end laps shall be at least 3' apart. Malarkey recommends the use of its SBS Polyester Cap Sheet ventral3hing material. CITY OF TUKWILA OCT 9 1986 BUILDING DEPT. -. CITY OF TU'Mp . 444.itBTu1As1nq'Jivieion Bou vard BUI )ING PERMIT APPLIC TION o y tAn4i3"�a9t e Control # (p- 5-0 Site Address 965 -981 Industry Drive Bldg. #31 Suite# Floor# Project Name /Tenant Koll Business Center Phase 3 Valuation of Construction 24, 069.00 Assessors Account# 95- 2798160 Property Owner Aetna Phone 203/275 -2395 Address One Civic Center Plaza, Hartford, Connecticut Zip 06143 Applicant The Koll Company Phone 575 -0765 Address 601 Strander Tukwila, WA Zip 98188 Architect /Engineer none Phone Address Zip Contractor Pacific Rainier Roofing, rL %CCtnse# PA— CI— FR— R248LC Phone 206/367 -2525 Address 10735 Stone Avenue North Seattle, WA Zip 98133 Class of Work: [] New Q Addition ❑ Tenant Improvement [] Remodel (residential) III Reroof ❑ Demolition ❑ Interior Demolition [] Other Describe work to be done Reroofing Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building 12,800 s.f. Square footage of tenant space Building Use Office /warehouse Will there be a change of use? ❑ Yes ig No If yes, describe change of use, including square footages of changed areas Will there be storage or use of flammable, combustible or hazardous materials on the premise or area of construction? ❑ Yes fft No If yes, explain I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION Applicant /Authorized Agent (signature) /I APPLICATION AND KNOW THE SAME TO BE TRUE AND TO DO THIS WORK. ,ft1171--4-- Date 9/22/86 (print name) Monty D. Moore Contact Person (please print) Monty D. Moore Phone 206/367 -2525 OFFICE USE ONLY FEES: Building Permit Fee (000/322.100) $ 2143,0 O Receipt# Date Paid • Plan Check Fee (000/345.830) Receipt Date Paid Bldg Code Sur Charge (000/386.904) 1.50 Receipt# Date Paid Energy Sur Charge* (000/386.907) Receipt# Date Paid Other ( ) Receipt# Date Paid V *New construction only TOTAL au (OWES: $ ) SQUARE FOOTAGE /BUILDING USE INFORMATION Square Footage of Entir Building: FLOOR USE /Occ Type SQ.FT. OCC J AD USE /Occ Tvpl SQ.FT. OCC LOAD USE /Occ T p S0 FT. OCC ,1 fAQ. TOTAL SQ.FT. TOTAL OCC. TOTAL TRACKING DEPT. DATE IN, DATE OUT COMMENTS BLDG FIR cisM) �� ,0 `— a,^' p Approved for Issuances Type of Const. To Mahan: Date Approved: Approved (Initials) Per letter dated Fire Protection: sprinklers ❑ Detectors PLNG PWp Approved (Initials) • BAR [f LAND USE /SEPA CONDITIONS Zoning Setbacks: N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: Approved (Initials) Per letter /plans dated