Loading...
HomeMy WebLinkAboutPermit 4554 - Jones - Northwest Seals - HVAC CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done Site Address 14600 Interurban Avenue S. Building Use Warehouse /Office Property Owner Elmer and Bobbie Jones Address Contractor Address HVAC BUILDING PERMIT 1,g• - .1 PERMIT # qs75'5/ Control # 86 -381 Suite # Tenant Northwest Seals Assessors Account # -0/4- Phone # 885 2781 Zip 98188 881 -3060 Zip 98052 %/ 14840 N.E. 95th Redmond FOR BUILDING PERMIT ONLY Phone APPROVED FOR TSS1iMif F BY- Sq. Ft. Office Storage/ Warehouse Retail Other Occ. Load 1st F1. 2nd F1. 3rd Fl. Total Fire Protection: ( Sprinklers E Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ sq. ft. @ sq. ft. @ sq. ft. @ 1st F1. $ 2nd Fl. $ other $ other $ Total Valuation of Construction $24,380 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt # y 7ky $ 64.50 Receipt # yip/ $ 12.38 Receipt # $ Receipt # $� Receipt # $ Receipt # $ $ 76.88 FOR SIGN PERMIT ONLY Q Permanent E Temporary ❑ Single Face Building face EE Double Face EE Wall Mounted E Free Standing ❑ Other Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT 1 HAVE READ A GOVERNING T IS TYPE OF'- WORK'WILL E VIOLATE /OLD 'CAN P' sV Signe EXAMINE PLIED OF THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES TH WHETHER SPECIFIED HEREIN OR NOT. THE GRANT! G OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO THER STATE OR LOCAL LAW REGULATING TRUCTIO THE %��MANCE OF CONSTRUCTION. Date _ NSED NTRACTORS DECLARATION ess and Professions Code, and�nl�_licens s i fu1 iz and effect. Date �� • I hereby affirm that I am tensed er pr vi 1 Contractor (signature h ill • ( ) 1, as owner offered for ( ) I, as owner Owner (signature) OWNER - BUILDER DECLARATION of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or sale. of the property, am exclusively contracting with licensed contractor's to construct the project. Date 'CITY OF TUKWILA Building Division ` 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done Site Address Building Use Property Owner Address Contractor Address HVAC BUILDING PERMIT PERMIT # `/s 5-,/ Control # 86 -381 14600 Interurban Avenue S. Warehouse /Office Elmer and Bohbie Jones 14600 Interurban S. Hank Saydam & Aseociate5. 14840 N.E. 95th Suite # Tenant Nortilw„t 'gp�1s Assessors Account # 41/4- FOR BUILDING PERMIT ONLY Tukwila Inc. Redmond. WA Phone # 865 -2781 Zip 9i1Q8 Phone # 831..3060 14 Zip 99052 S q • Warehouse e Retail Other Occ. Load 1st F1. 2nd Fi. 3rd F1. Total Fire Protection: L] Sprinklers [[ Detectors Zoning Type of Construction Special Conditions Fees' sq. ft. @ sq. ft. @ sq. ft. @ sq. ft. @ 1st F1. $ 2nd F1. $ other $ other $ Total Valuation of Construction $ 24!380 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt #,,p- $ Receipt # :, -, s ' $ Receipt # $ Receipt # $ Receipt # $ Receipt # $ 64.50 $ 76.88 FOR SIGN PERMIT ONLY Q Permanent 1=1 Temporary L Single Face [] Double Face L] Wall Mounted ❑ Free Standing L] Other Building face Setbacks: Front Square Footage of each sign face Total square footage of sign Special Conditions Side Side Rear THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED 1S NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT l HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TU GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. Signed Date LICENSED CONTRACTORS DECLARATION I hereby affirm that I am licensed under provisions of the Business and Professions Code, and my license is in full force and effect. Date Contractor (signature) OWNER- BUILDER DECLARATION ( ) I, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature) Date CITY OF TUKWILA 'Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1849 • Type of. Inspection //G!'/fe , ) - c %24.2e_ Site Address /Y6-3t e9 620e , Project Requestor ,T) Phone # Special Instructions .w k, ...+, s•: avxt.+ .w�.,:urami�.`:Eeatr.+r+n.(, *xa �J = INSPECT" ON RECORD PERMIT # V.557 /720? Date Wanted 007 Date a.m. Inspection Results /Comments: Inspector Date // 4 CITY OF TUKWILA , INSPECT ON RECORD Building Division �� 6200 Tukwila,,tWashington ul98188 (2O6) 433 -1849 PERMIT # 4/5-6-`1 • Date (a_ 9 Type of Inspection (-f (/4-a- Date Wanted 4 ' 4: a.m Site Address ) Leto o s4.c4.,1in...., ,4,, c, Project /J/ 5" Requestor Tr,+%A, rAnA-1.£{/ — .206U Special Instructions Phone # Inspection Results /Co ments: Inspector #4/k'l Date 1/I?4 COMMERCIAL IOAD ESTIMATE FOR NOR'rimEsT SALES INC BY [SANK SAYDAM & ASSOCIATES 06/15/86 RECEIVED CITY OF TUKWILA (C,► 30 1986 BUILDING Derr. 1st FL -NG? SALES IN 06/15/86 SEATTLE WASHINGTON CONST= 30W /10R/ 30B WALL COLOR: LIGHT LAT = 48 ALT = 14 ID= 78/50 : 72 ROOF COLOR: DARK SLR# 30206831.6 D. F3. TE 4P TOTAL TONS RSH 'PONS 1. JUN AT 9 A.M. 72.4 4.54 3.73 2. JUL AT 9 A.M. 73.4 4.59 3.77 3. AUG AT 10 A.M. 75.2 4.21 3.43 4. SEP AT 12 NOON 78.0 5.07 4.19 5. AUG AT 1 P.M. 82.0 4.52 3.61 6. JUL AT 2 P.M. 84.0 4.10 3.23 7. JUL AT 3 P.M. 85.0 4.06 3.20 ZONE HEATING--> = 29,998 W /IN1IL= 29,998 C.F.M = C.F.M. 1,769 1,789 1,625 1,986 1,715 1,533 1,518 718 INPUTS CEILING PARTITION FLOOR SKYLIGHT TRANSMISSION E'ACT. 0.00 0.00 0.00 0.00 TEMP DIF'F HEATING 0 0 0 50 TEMP DIET COOLING 0 0 0 0 FLOURESCENT LIGHTS - Y SOLAR FACTOR SKYLIGHT = 0.00 OVERHANGS AND /OR REVEALS PRESENT (FI') TYPE 1 TYPE 2 TYPE 3 HEIGHT OF OVERHANG - 0.00 0.00 0.00 - 3.00 0.00 0.00 6.00 0.00 0.00 - 0.00 0.00 0.00 - 1.00 1.00 1.00 DEPTH OF OVERHANG HEIGHT OF WINDOW - DEPTH OF REVEAL NUMBER FLOORS EFFECTIVE AVERAGES FOR ZONE TJJADS OR OP -COST : EXPOSURE: N. NE I. SE S. SW W. NW WALL TRANS. FACTORS 0.05 0.00 0.05 0.00 0.05 0.00 0.00 0.00 GLASS TRANS FACTORS 0.55 0.00 0.55 0.00 0.55 0.00 0.00 0.00 GLASS SOLAR FACTORS 0.63 0.00 0.63 0.00 0.63 0.00 0.00 0.00 ROOF TRANS. FACTOR = 0.08 SKYLIGHT TRANS. FACTOR = 0.00 NUMBER OF PEOPLE _ TOTAL LIGHTS = 4, OTHER ELECTRICAL = N. TYPE 1 GLASS AREA= E. TYPE 1 GLASS AREA= S. TYPE 1 GLASS AREA= S. TYPE 1Sf•IADE AREA = TOTAL GLASS AREA = TOTAL GLASS AREA = SKYLIGHT AREA = SKYLIGHT AREA = N. TYPE 1 WALL AREA = E. TYPE 1 WALL AREA = S. TYPE 1 WALL AREA = 'TOTAL WALL AREA = PARTITION AREA = CEILING AREA = FLOOR AREA = AREA OF ROOF = OUT'PU'TS 24 SENSIBLE PEOPLE TOAD = 5,902 818 LIGHTING TOAD = 20,555 0 OTHER ELECTRICAL = 96 N. 'TYPE 1 GLASS SOLAR = 318 E. 'TYPE 1 GLASS SOLAR = 237 S. TYPE 1 GLASS SOLAR = 107 S. TYPE 1 SHADE SOLAR = 651 TOTAL GLASS SOLAR = 651 TOTAL GLASS TRANS. = 0 ZOTAL SKYLIGHT SOLAR = 0 TOTAL SKYLIGHT TRANS = 0 606 8,584 13,789 674 23,653 0 0 0 129 N. TYPE 1 WALL .TOAD = -38 276 E. TYPE 1 WALL, LOAD = 87 150 S. TYPE 1 WALL LOAD = 93 555 'TOTAL WALL TRANS. = 143 0 TOTAL PART. 'TRANS = 0 TOTAL CEILING TRANS = 0 TOTAL FLOOR TRANS = 0 ROOF LOAD = 0 0 0 0 ti 1st. FL -NW SALES IN SAFETY FACTOR EVAP FAN H.P. = MISC SENSIBLE - V ENTILATION CFM = MISC. LATENT = NUMBER OF PEOPLE= VENTILATION CFM = TOTAL CFM -STD AIR= 0% SAFETY B.T.U.S = 0 1.42 FAN HEAT GAIN - DT = 4,360 0 MISC. SENSIBLE = 0 120 0. A. SENSIBLE LOAD = 0 0 MISC. LATENT = 0 24 PEOPLE £A ENT LOAD = 4,938 120 O.A. LATENT LOAD = 1,315 1,986 TOTAL LATENT LOAD = 6,253 ROOM SENSIBLE = 50,252 ROOM LAT. TOAD = 4,938 *************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1st FL -NW SALES IN = 60,866 BTU'S OR 5.07 TONS <-- RUN FOR # 4. SEP AT 12 NOON - -> GRAND TOTAL LOAD LOAD AREA (SQ FT) _ TOTAL CFM -STD AIR = PARTITION LOAD = VENTILATION LOAD = FLOOR HEATING TOAD= GLASS HEATING LOAD= SLAB HEATING LOAD = WARM UP LOAD = 2,409 SQ. ET PER TON 1,986 CFM PER SQ Fr _ HEATING LOAD 0 CEILING TOAD = 6,625 ROOF HEATING LOAD = 0 SKYLIGHT LOAD = 17,903 WALL HEATING LOAD = 4,743 INFIL HEAT LOAD = 6,104 H TOAD WITH VENT = COIL SELECTION PARAMETERS DB TEMP ENT /LVG = 78.0 / 53.0 TOT SENSIBLE LOAD = WB TEMP ENT /LVG = 62.9 / 52.3 TOTAL COIL TOAD = SPECIFIED ROOM RH = 50% RESULTING ROOM RH = TERM AIR TEMP = 55.00 / 110 DEGREES ROTATED = 0 T. ST. EVAP FAN = 2.50 NON - CEILING RETURN BLDG. '0' FACTOR= 0.32 HS &A 475 0.82. 0 0 0 1,249 0 36,622 54,612 60,866 42% 2nd FL -NW SALES IN 06/15/86 SEA'I'rLE; WASHINGTON LA'I' = 48 ALT = 14 CONST= 30W /10R/ 30B ID= 78/50 : 72 WALL COLOR: LIGHT ROOF COLOR: DARK - SER# 30206831.6 • D.B.TEMP TOTAL TONS RSH TONS C.F.M. 1. JUN AT 9 A.M. 72.4 4.39 3.59 1,702 2. JUL Al' 9 A.M. 73.4 4.45 3.64 1,729 3. AUG AT 10 A.M. 75.2 4.08 3.31 1,569 4. SEP AT 12 LOON 78.0 4.99 4.11 1,950 5. AUG AT 1 P.M. 82.0 4.60 3.69 1,752 6. JUL At 2 P.M. 84.0 4.31 3.42 1,624 7. JUL PP 3 P.M. 85.0 4.33 3.44 1,633 ZONE HEATING--> = 31,038 W /INFIL= 31,038 C.F.M = 743 TRANSMLSSION FACT. TEMP DII?1? CHEATING TEMP DIFF COOLING FIOURESCENT LIGHTS - Y OVERHANGS INPU`1'S CEILING PARTITION FLOOR SKYLIGHT 0.00 0.00 0.00 0.00 0 0 0 50 0 0 0 0 SOLAR FACTOR SKYLIGHT = 0.00 AND /OR REVEALS PRESENT (FT) TYPE 1 TYPE 2 0.00 0.00 3.00 0.00 6.00 0.00 0.00 0.00 1.00 1.00 HEIGHT OF OVERHANG DEPTH OF OVERHANG HEIGHT OF WINDOW DEPTH OF REVEAL NUMBER FLOORS EFFECTIVE CTIVE AVERAG EXPOSURE: WALL TRANS. FACTORS GLASS TRANS FACTORS GLASS SOLAR FACTORS ROOF TRANS. FACTOR ES FOR ZONE LOADS OR OP -COST : N. NE 0.07 0.00 0.55 0.00 0.63 0.00 = 0.05 NUMBER OF PEOPLE = TOTAL LIGHTS = OTHER ELECTRICAL = N. TYPE 1 GLASS AREA= E. TYPE 1 GLASS AREA= S. TYPE 1 GLASS AREA= S. TYPE 1SHADE AREA = TOTAL GLASS AREA = TOTAL GLASS AREA = SKYLIGHT AREA = SKYLIGHT AREA = N. TYPE 1 WALL AREA E. TYPE 1 WALL AREA S. TYPE 1 WALL AREA TOTAL WALL AREA PARTITION AREA CEILING AREA FLOOR AREA AREA OF ROOF TYPE 3 0.00 0.00 0.00 0.00 1.00 E. SE S. SW W. NW 0.07 0.00 0.07 0.00 0.00 0.00 0.55 0.00 0.55 0.00 0.00 0.00 0.63 0.00 0.63 0.00 0.00 0.00 SKYLIGHT TRANS. FACTOR = 0.00 OUTPUTS 24 SENSIB1E PEOPLE LOAD 4,818 LIGHTING LOAD 0 OTHER ELECTRICAL 96 N. TYPE 1 GLASS SOLAR = 318 E. TYPE 1 GLASS SOLAR = 216 S. TYPE 1 GLASS SOLAR = 97 S. TYPE 1 SHADE SOLAR = 630 'TOTAL GLASS SOLAR = 630 TOTAL GLASS TRANS. = 0 TOTAL SKYLIGHT SOLAR = 0 'TOTAL SKYLIGHT TRANS = 5,902 = 20,555 = 0 606 8,584 12,568 614 22,371 0 0 0 -59 136 = 165 = 242 0 0 = 0 270 129 N. TYPE 1 WALL LOAD 276 E. TYPE 1 WALL TOAD 171 S. TYPE 1 WALL .TOAD 576 TOTAL WALL TRANS. 0 TOTAL PART. TRANS 0 TOTAL CEILING TRANS 0 'TOTAL FLUOR TRANS 2,409 ROOF LOAD 2nd FL -NW SALES IN SAFETY .FACTOR = EVAP FAN H.P. _ MISC SENSIBLE = VENTILATION CFM = MISC. LATENT = NUMBER OF PEOPLE= VENTII:ATION CFM = TOTAL CFM-STD AIR= 0% SAFE'T'Y B.T.U.S 1.40 FAN HEAT GAIN - D`1' 0 MISC. SENSIBLE 120 0. A.SENSIBLE TOAD 0 MISC. LA'T'ENT 24 PEOPLE LATENT LOAD 120 O.A. LATENT LOAD 1,950 TOTAL LATENT LOAD ROOM SENSIBLE = 49,340 ROOM LAT. t_DAD *************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 2nd FL -NW SALES IN = 59,869 BTU'S OR 4.99 RUN FOR # 4. SEP AT 12 NOON - -> GRAND 'TOTAL LOAD LOAD AREA (SQ FT) _ TOTAL CFM-STD AIR = P1RTITION TOAD = VENTILATION :CHAD = FLOOR HEATING LDAD= GLASS HEATING TOAD= SLAB HEATING LOAD = WARM UP LOAD = = 0 4,280 0 0 0 4,938 1,310 6,248 4,938 TONS < -- 483 0.81 0 5,420 0 2,016 0 37,663 53,621 59,869 42% 2,409 SQ. FT PER TON 1,950 CFM PER SQ FT HEATING LOAD 0 CEILING LOAD = 6,625 ROOD IDEATING LOAD = 0 SKYLIGHT LOAD = 17,325 NAIL HEATING LOAD = 0 INFIL HEAT LOAD = 6,277 H TOAD WITH VEtr COIL SELECTION PARAMETERS DB TEMP ENT/LVG = 78.0 / 53.0 TOT SENSIBLE LOAD = WF3 TEMP E'N'T' /LVG = 63.0 / 52.3 'TOTAL COIL TOAD = SPECIFIED ROOM RH = 50% RESULTING ROOM RH = TERM AIR TEMP = 55.00 / 110 DEGREES ROTATED = 0 T. ST. ILVAP FAN = 2.50 NON- CEILING RETURN BLDG. '0' FACTOR= 0.14 US &A WAREHOUSE /MN SALES ** 06/18/86 LAT = 48 ALT = 14 ID= 78/50 : 72 ROOF COLOR: DARK SER# 30206831.6 0.13. TEMP TOTAL TONS RSH TONS SEATTLE; WASHINGTON CONST= 30W/10R/ 3013 WALL COLOR: LIGHT 1. JUN AT 9 A.M. 2. JUL AT 9 A.M. 3. AUG AT 10 A.M. 4. SEP AT 12 NOON 5. AUG AT 1 P.M. 6. JUL AT 2 P.M. 7. JUL AT 3 P.M. ZONE HEA'I'ING - -> = TRANSMISSION FACT. TEMP RIFF HENTING TEMP DIFF COOLING FLOURLSCENT LIGHTS EFE`ECTIVG AVERAG EXPOSURE: WALL TRANS. FACTORS GLASS TRANS FACTORS GLASS SOLAR FACTORS ROOF TRANS. FACTOR 72.4 4.51 3.54 73.4 4.56 3.59 75.2 4.68 3.70 78.0 5.12 4.07 82.0 5.62 4.42 84.0 5.83 4.63 85.0 6.03 4.81 43,027 W /INFI.L= 43,027 C.F.M = C.F.M. 1,681 1,704 1,756 1,930 2,099 2,194 2,281 1,029 INPUTS CEILING PARTITION FLOOR SKYLIGHT 0.00 0.00 0.00 0.00 0 0 0 50 0 0 0 7 - Y SOLAR FACTOR SKYLIGHT = 0.00 ES FOR ZONE LOADS OR OP -COST : N. NE E. SE S. SW W. NW 0.07 0.00 0.00 0.00 0.07 0.00 0.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 = 0.05 SKYLIGHT TRANS. FACTOR = 0.00 NUMBER OF PEOPLE = TOTAL LIGHTS = OTHER ELECTRICAL = TOTAL GLASS AREA = TOTAL GLASS AREA = SKYLIGHT AREA = SKYLIG[-r1' • AREA = N. TYPE 1 WALL AREA = S. TYPE 1 WALL AREA = W. TYPE 1 WALL AREA = TOTAL WALL AREA = PARTITION AREA = CEILING AREA = FLOOR AREA = AREA OF ROOF = OU'1'1 uTs 37 SENSIBLE PEOPLE LOAD 9,300 LIGHTING LOAD 0 OTHER ELECTRICAL 0 TOTAL GLASS SOLAR 0 TOTAL GLASS TRANS. 0 TOTAL SKYLIGHT SOLAR 0 TOTAL SKYLIGHT TRANS 1,950 N. TYPE 1 WALL LOAD 1,200 S. TYPE 1 WALL LOAD 1,900 W. TYPE 1 WALL LOAD 5,050 'TOTAL WALL TRANS. 0 TOTAL PART. TRANS 0 TOTAL CEILING 'TRANS 0 TOTAL FLOOR 'TRANS 3,720 ROOF LOAD 9,114 = 39,676 = 0 0 0 = 0 0 = 478 1,367 1,758 = 3,602 0 0 0 5,322 WAREHOUSE/NW SALES** SAFETY FACTOR EVAP FAN H.P. MISC SENSIBLE = VENTILATION CFM = MI SC . :LATENT = NUMBER OF PEOPLE= VENTILATION CFM = TOTAL CFM -STD AIR= 0% = 1.31 0 186 0 37 186 2,281 57,714 **************** * * ** * * * * * * * * * *•k * * * * * * * * * * * * *** ROOM SENSIBLE = SAFETY E3.'.r. U. S FAN HEAT GAIN - Dr MISC. SENSIBLE 0. A.SENSIBLE LOAD MISC. LATENT PEOPLE LATENT LOAD O.A. LATENT LOAD TOTAL, LATENT LOAD ROOM LAT. LOAD - -> GRAND TOTAL LOAD LOAD VENTILATION TOAD = FLOOR HEATING LOAD= GLASS HEATING LOAD= SLAB HEATING LOAD = WARM UP LOAD = 0 4,006 0 1,432 = 0 = 7,626 1,617 9,243 7,626 WAREHOUSE /NW SALES ** = 72,395 BTU'S OR 6.03 'PONS < -- RUN FOR # 7. JUL AT 3 P.M. 10,230 ROOF HEATING LOAD = 0 SKYLIGHT LOAD = 0 WALL HEATING LOAD = 7,176 INFIL HEAT LOAD = 8, 876 H LOAD WITH 1EN1' = COIL SELECTION CTION PARAMET ''RS DB TEMP ENT /LVG = 78.6 / 53.4 '10T SENSIBLE LOAD = W6 TEMP ENT /LVG = 63.6 / 52.7 TOTAL COIL TOAD = SPECIFIED ROOM RH = 50% RESULTING ROOM RH = TERM AIR TEMP = 55.00 / 110 DEGREES RO'1'ATEO = 0 T. ST. EVAP FAN = 2.00 NON - CEILING RETURN BLDG. 'U' FACTOR= 0.06 HS &A 9,300 0 17,675 0 53,257 63,152 72,395 43% bITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 MECHANICAL PERMIT APPLICATION CONTROL# P-38/ Site Address /t' ,(9O 7640.)tha 1 7...) unA Suite# �( Floor# Name /Tenant 416912thrLxs1 °a/ Valuation of work ;2_,(1,/,:;5'n Assessors Account # Property Owner /y/Aw-5//nlie. deems Phone S --Z7f3 / Address /'/(ADO er ,rh 4 5. - /cam l& Zip Appl i cant ,z/ar / A .S4ya4>ti-M d /(S r /4 /S ..;t/L. Phone 6:6,7-3 e9.,i9 Address /460 757/-A //J Zip M9132.- Architect /Engineer /,70tVi e,..) 'e'7 /e Phone Sf35--'4?-h51 Address /J/WJ /1. S rA0> �/ sc���P,�q Zip Contractor License# /- 4,MS4T -/526 Phone P43/-3C)69 Address /4640 //E. 964 /ee4/ , 4 4J( Zip r%RDS�. Describe work to be done �'it s /a / /,CI,. /0-71. e9( C,u rc s cc/ (A,;( -- 63,i6////m. • 6)17A3 Indicate the type of equipment to be installed, rating /size of equipment, and number of each: TYPE M2c /C )4)/7 :3 RATING /SIZE NUMBER Two (2) sets of plans must be submitted meeting the application requirements of Section 302(b) and (c), 1985 Uniform Mechanical Code. Roof -top equipment work requires submission of building elevations. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWN R'S AUTHORIZATION Tg1DO THIS WORK. Applicant/Authorized Agent (signature . jc.& Contact Person (please print) Arne S4yDA Date 1/C/ i4d" C5- Phone 88(-3060 OFFICE USE ONLY FEES: Basic Permit Fee (000/322.100) $ 45,00 Receipt# Unit Fee (000/322.100) y9,S0 Receipt# Plan Check Fee (000/345.830) /a.3'5 Receipt# Other ( / ) Receipt# TRACKING DEPT. DATE IN Date Paid /2-9 Date Paid / s -q Date Paid ,,, —/ Date Paid TOTAL 7‘ .8'S7 (OWES: $ DATE COMMENTS BLD PLNG pprove or ssuance Approved (Initia1s) 1 vk e Sat,P . .7.,I:1,!1*-41111043.• 4. 4,- 744;7' :,••:1,1-#41. • .•••,..i..8P 14 0 \ ; • Warehouse 1 A (-)0c3 1 200 1 Z-00 F . 8 1 -1- 811(6 Icr izt" 200 jr - -71 - - /10 1 4. ; 2OO WAREHOUSE & 2nd FLOOR HVAC PLAN ec,A4_ % /e," - Warehouse L07 ELEVATION VIEW Ap-‘0061101 -1---- 1 1— Opt* .11.1111101111•■■■••••••■•••■••■• Office a." X N■WWAVAIK\ .._12f5crz wiyininbnyw,: 8'10 —414ishisk, ..■•••IIIMMIIIIIIIINNINNII■••••••■11111.111.1••••■ 11.110.11111.4.••■•••••••■■• 1 .41.011 0 200 4.i. 20'1,0 -- — 1(00.1 TYPeAL. TO ALL (11) 100CFAN E'ICP .... 41. • 2- ND FLOOR UN fl 5 TO CAWCITY LNOX C5 tO -6,55-75 1 , I ' I 1 i 1 ; I I --' • I i I 1 100 200 )140.**4 8110 1 _16-1 FLCrik. UNIT 5 ION G-APAQTY l5-1•1NOX Warehouse 11,1/aM01,,•■••■11.....■ 1 I I -.7 -r - i ; ; f 10" )(12:----" 200 L elY ttAtAMAAN‘7 01101111.■■ 1 .\\/"\z, 0114+111114411-11L111 Office i-iz—,---. 1 i 1 . I= ___ I=1. ,,,,t ........tr :...,._■,A T if -s • Office 50,44.„E 1/6" • ••■••■••■••■■••■•1•1•1ft•••••••/ •10*•1•1 1P•141401# 3- •••-•-••■•• odo 1 4'xiZ x z6'x1;4\" TYPICAL_ TO AL-1-(14-') SLOT IFU F 00 C_FAA , " ci) . • 4,re -11fAVIWINAMM114 175 co t • IL_ I i_ 11 1, I-1 1--1 • ' • _I-- - 1, • 1 FIRST FLOOR HVAC PLAN ecAE. 1/6' -0 W+.10(..1(z-W. UNIT' 7 SECTION VIEW 4.1•1111•11.1■11#14■■• .14■7•MaNdMI#41#011.411/..4444........•••■•• i'-0" Office 9 2C,r) •0114.4.4.44. 1 4 - •••••■•••■•■■■•■••■■••■■• ijI - ,-; - - ? 6 • ICM I id1111 111111111 111111111 „ ••■•••,.es•rr, • CITY OF TUKWILA APPROVED OEt -8 T986 AS NOTED ontIsInm eelatt$Vgi 4. RECEIVED CITY OF ItIKW1LA C CT 30 1986 BUILDINC1 DEM 0M, uj 1- REVISED: 4.-4..t.I.4 14-4` 4,44k4 DIMENSIONS (inches) GCS16 UNIT WITH REMD16 ECONOMIZER DAMPER SECTION AND RMF16 ROOF MOUNTING FRAME BLOWER MOTOR INDUCED DRAFT BLOWER �^ '- - -- SLOWER 11rrr'rrr ; i401! CENTER''" ; CIF eHAVITr FLUE/VENT • OUTLET • MEAL' it - - - -' EXCNAIIOER I• EVAPORATOR1- u,.wr 14-- COIL ,, i II FILTERS -K 11-1// -e. OPTIONAL REMDTS ECONOMIZER DAMPERS (Field butga ail TOP VIEW CONDENSER COIL INTAKE MR 4 CONDENSER COIL FAX IDu& Few On (303*131531 BACK VIEW 1-1/2 CORNER WEIGHT (Ibs.) Model No. *au I. -' J GCS16 -953 1 256 28 _ 295 256 GCS16-1353 1 274 30-1/8 404 354 CENTER OF GRAVITY lin.) Model= K I. GCS16 -S63 24 41 GCS16-1353 28 _ 41 _ M.- o. 1 A : C 0 Q 24 GCS16 -963 F 39 88-1/2 48 28-9/16 GCS16-1353 46 94 60 34-9/16 30-1/8 OpftDENSER COIL EXHAUST AIR o/TioNAI GED1G GRAVITY EXHAUST DAMPERS IRMd Inet,N$ Seth saw CONDENSER SECTION END VIEW INSTALLATION CLEARANCES (Inches) GCS16 BASIC UNIT \ • - • wit:!: k . 'r is ivTOa._.f �1 JAW U M\ \\\ O VAMP NOTE - Top Clearance Unobstructed. GCS16 UNIT WITH REMD16 ECONOMIZER DAMPER SECTION NOTE - Top Clearance Unobstructed. WAREHOUSE A/C UNIT DETAILS GCS16-953 1-13/11 113/14$ I C 0 DIMENSIONS (inches) RMV?I SERIES RCii1�,�MOW 11! FRAMIR WffW. Q UB(tE Ott �)i?i 11111 PI 0 • E • ° `I 493/8 • 17-16/16 4w1 1. ,,s r\ IA ' -44 3/11 Al L, 32 £i crone* t t •1 Aa -1 . 5Tlhr IF..... 1 21 0- AA „4 OffUltff WO 0•011W3 3t - £ S wo--•• -- GCS1O(X1 -511 -51375 /tenon I 1,13 114 1.3/114 1.13/11 4 CORM* AMO(f N twooftY tw haw. Arrow* 3/111 sorrow PAWLS (rwrwwnMl � RRUI snap • NOR -raw/ wwt nor :war/ oleo. cow-are of bona Modal No. I A B C 0 • E F 1: !,qi • 834/2 493/8 • 43 17-16/16 4w1 RMF16- 135 92 -1/2 88-7/8 58-1/2 54-7/8 25-1/4 3 -3/16 O Corner Weights -- (lbs.) MotMNo. 1.1111111111111 ' K __ Ira Gcsioi 1.281 -50 I 96 87 Gcslax)- 311-50 1101 93 ElifirINIS GCS1000- 10-411.50 1 106 98 iI 26-3/4 GCS 1000 411413- 7S 1 107 ralliti GCS1O(X1 -511 -51375 132 GCS1OX)461463 -75 1 136 En 153 El GCS1OIX1311.S13-75 Ira 117 EMI am GCS10X1-961.6 3-7S 1 126 124 161 158 Center of Gravity (In.) Model No. ' K GCSIOX)- 261.60 22-1/4 .]Ir GCS1OIXI.3114o i n -315 GCS10X 311 . , GCSIO(XI411.5O i 22- 112 23-7/8 GCS1000411413-75 1 24-1/4 26-3/4 GCS100N61483 -75 I 25-1/8 28.7/8 GCS1O(X1 -511 -51375 I 24.7/8 26-314 GCS1aX1- 61da3-75 I 25 25.3/4 CONDENSER VIEW 1.14 BASIC UNIT -- DIMENSIONS (inches) EVAPORATOR V 'LPL" r cos. PLAN VIEW WOE VIEW M o. GCS10(X1- 261 -60, GCS10(X)- 311.60 & GCS10(X)- 411-60 GCS1010- 411413.76, GCa10(XI.481. 483.75, 1,. • :au+rsioes 1+ r 061/2 Roof UountI&q helm 13 Frame O*Wg J1-3/4 1.2/4 1.3/4 SUPPLY AIR OPENING 19 3/1 DIVIDER (Furnished; RETURN AIR OPENING , o ---- -24 19-3/4 1-3/4 25 sr 28.3/4 UNIT MOUNTING PLATFORM !Furnished) uNIT SUPPORT c11ANNF3s 38.3/4 U-- i'le'um 7 1a /4 NAILER STRIP II DIVIDER PANEL !Furnished) I� (Furnished) 11 Root deck may be emitted w$tMn confines of Irma. 14 7* TOP VIEW 8 1:74T:7r- NIL= MILAN+ 16*11.15 i<1io!. .]Ir D FROM VIEW NAILER STRIP Fumishad) RMFG10 MOUNTING FRAME RIGID INSULATION (Field Supplied) MOUNTING PLATFORM (Furnished with RMFG101 COUNTER FLASHING / (Field Supplied) CANT STRIP IFiNd Supplied) ROOFING MATERIAL saaosi OUTDOOR NA H900 OPTIONAL ROOFTOP ACCESSORIES - DIMENSIONS (inches) GCS1000 UNIT WITH RDE1046 DUCT ENCLOSURE OR REMD10416 ECONOMIZER UsO f is Ova Ersuere. BASIC UNIT WITH R0i:1046 DUCE EIN LOSURE 5011.'6.4 coaniiTIAl10M a i.-si rao- ANo ileum TRANSFTNw Node VOWROA IRWOdo Ar MO VIEW Comer Weights (Ibe.I 19*8iC UNIT WITH 0 REMD1041/ ECONOMIZER SECTION 74.1/$ a mamei t 3n * inset 79-7/0 ** 71i. A115 0106 • 4'1/11 ecancuaet. an a anal • /S 10004»31 AM. e11 a 2r- OUTDOOR IDDIAURT Ill 'MOOT/ T =we la 1111110151111 lnemoo w1 aTR41/Sf a /O+US 0110rer• r }err • NIL= MILAN+ GC6101X1.261 -60. Ii .]Ir MAKE & MODEL iit��� GCS10X 311 . , GCS100•311 -60 li�re� CFM NCEN 201 MINI GCS10IXI- 411.50 GC81aX)- 411.413rs IMMINIENii 146 wail 1111EAMIIIIIMIll GCS1ax 11-48376 ilieNI GCS1000 -411- 413-76 e,9, AA-"H -7 5 TON tq MOM 219 190 GCS1000- 461.463- - IIDESEIN 161 INUANIIIIIIIE111111111E1111 7 5 77o -1E.1.1.) C1ri GCSUaXI- 611 - 513.75 kM v 13':.i' -Fame. .E:Mb l , fC01.I(JW\' 160 t- ..:NNK.)x C::.t0X 3-75 I1'Z1 192 GCS10(X • • 1.66376 ; 116 212 Zar6 •.��c.) /3/ 4,0 1 %7 RWpm R. At ROOF MOUtoradt FRAME SAW RR SIDE VIEW Center of Gravity lin.) NOTE - Cams ***Me 411 lot GCS100) unit with REM01046 Economiser and NOTE - 0h1Ermans are for GC8IO X1 unit ■i61 REM010.10 Economizer and RMFG10.85 Roof Mounting Frame install/. 11M010-86 Roof Mounlrq Frame Inwood. GCS10(X) UNIT WITH RTDE10.66 DUCT ENCLOSURE NOTE - Foe Top VMw of Bundy and Roam Air Locations. RNar to *min pbovs. -634/8 * 1111 RETWRN cr- AIR.... AIR 1t OUTDOOR AIR N000 71.111 OCSM0 3i1. 311 a 411411 79.7/9 OCIMx1414.71. et is 4 al SI "141E-11"----:31311 nl 91.7/1 F1BRMSN CP �� t OucT ' ) NE RETURN AIR ALTER lAteWNel wIM RT01N4E1 274111 42.6/8 9' COItau1AI1ON SUP I Y AND RETURN TRANMTWN Re1iM1 42 r"7". T:TI N SRPG19•S3 T414.11M 1M iRf1/ krel4SW) wf,w AM Ne11 wMr �ITD41/,s 4 r0 A1/IS ON1ueN!• END VIEW - 27 - 1ST AND 2ND FLOOR A/C UNIT DETAILS GCSIO'-653-'75 RMN3ISA ROOF MOUNTING FRAMS SIN VIEW 18 l 4, ''`K I WAREHOUSE UNIT W/ PLENUMS GC: 100461-60 A/C UN! MAKE & MODEL WT. GCS10X 311 . , ii��� li�re� CFM Galax) 11-60 IMES 36.1/2 •.EI COMPRESSOR RLA LRA --.- GC81aX)- 411.413rs IMMINIENii MFA 324/8 1-i�1. - GCS1ax 11-48376 ilieNI NM= e,9, AA-"H -7 5 TON 1('O /\A !'1 /+ -IIEj 911 -Sfax •sit -61 ' `SEN � .21 •07..:1' > i GCS10X0-1361 •••' • IMIIIIIIMeall 32 -1/8 IIDESEIN NOTE - Cams ***Me 411 lot GCS100) unit with REM01046 Economiser and NOTE - 0h1Ermans are for GC8IO X1 unit ■i61 REM010.10 Economizer and RMFG10.85 Roof Mounting Frame install/. 11M010-86 Roof Mounlrq Frame Inwood. GCS10(X) UNIT WITH RTDE10.66 DUCT ENCLOSURE NOTE - Foe Top VMw of Bundy and Roam Air Locations. RNar to *min pbovs. -634/8 * 1111 RETWRN cr- AIR.... AIR 1t OUTDOOR AIR N000 71.111 OCSM0 3i1. 311 a 411411 79.7/9 OCIMx1414.71. et is 4 al SI "141E-11"----:31311 nl 91.7/1 F1BRMSN CP �� t OucT ' ) NE RETURN AIR ALTER lAteWNel wIM RT01N4E1 274111 42.6/8 9' COItau1AI1ON SUP I Y AND RETURN TRANMTWN Re1iM1 42 r"7". T:TI N SRPG19•S3 T414.11M 1M iRf1/ krel4SW) wf,w AM Ne11 wMr �ITD41/,s 4 r0 A1/IS ON1ueN!• END VIEW - 27 - 1ST AND 2ND FLOOR A/C UNIT DETAILS GCSIO'-653-'75 RMN3ISA ROOF MOUNTING FRAMS SIN VIEW 18 l 4, ''`K I WAREHOUSE UNIT W/ PLENUMS EQUIPMENT SCHEDULE 1011111M110 .1•••01110111•11111•11111.1.11101111111•IMU1110•111116 44 'J it I'IIIr1Ii�Inllnti�nitlf,t, , )Illsil I►!tlnliilnilim !whip nnlnli mIll 1t in)hlil iu Inii nlllnn �J Aw O rlr- -RN \44E 20' "x 12! suiLY, ` Wr-AL- 6r- 4- - Z rLcn�.. -r)1:Aek. A..<11* NeaTh'ig•Q - 104e FIRST & 2nd FLOOR UNITS W/ PLENUMS VICINITY MAP r RECEIVED cn Y OF TVKWILA C.U;T 30 1986 MHG tom. li ® �w ® < CM) g O GO0 L1.1 (RO hieC?1 Fe:rW Norm aji w ut) w x cc 0 z • SOUTH 147th STREET & INTERURBAN AVE. a • w W CC A/C UN! MAKE & MODEL WT. COOLING HEATING EER CFM S.P. VOLTS PH. HTZ COMPRESSOR RLA LRA IFM FLA RPM MCA MFA REMARKS 1-i�1. - LE N X fic 5 4 -953 1100 Iles, 'N /AU-, e,9, AA-"H -7 5 TON 1('O /\A !'1 /+ -IIEj 911 9,:::. :f4X x .21 •07..:1' > i 24e-2 /3/ 6,o :so. e, 1 £ 4. o 7 5 77o -1E.1.1.) C1ri kM v 13':.i' -Fame. .E:Mb l , fC01.I(JW\' r) r--Fir f �, t- ..:NNK.)x C::.t0X 3-75 -�c1p I�r• vv/ Ace. 57, AA mt-t .s 1UN. .58 Sri;= -�-1 4, 2 2,OEX) 49/4 ST W2(.1. r at o?.� a Zar6 •.��c.) /3/ 4,0 1 %7 107.0 4,(r, sE.`f Crm. 'TUE ICS - �5 1 T PNc. 1cM1.--c4 I(.) -(05 -Kcor vikAME. 1.,S fR.I\V EQUIPMENT SCHEDULE 1011111M110 .1•••01110111•11111•11111.1.11101111111•IMU1110•111116 44 'J it I'IIIr1Ii�Inllnti�nitlf,t, , )Illsil I►!tlnliilnilim !whip nnlnli mIll 1t in)hlil iu Inii nlllnn �J Aw O rlr- -RN \44E 20' "x 12! suiLY, ` Wr-AL- 6r- 4- - Z rLcn�.. -r)1:Aek. A..<11* NeaTh'ig•Q - 104e FIRST & 2nd FLOOR UNITS W/ PLENUMS VICINITY MAP r RECEIVED cn Y OF TVKWILA C.U;T 30 1986 MHG tom. li ® �w ® < CM) g O GO0 L1.1 (RO hieC?1 Fe:rW Norm aji w ut) w x cc 0 z • SOUTH 147th STREET & INTERURBAN AVE. a • w W CC