HomeMy WebLinkAboutPermit 4751 - Tandy Corporation - Tenant ImprovementCITY OF TUKWILA
Building Division
6200 Southcenter Boulevard
Tukwila, Washington 98188
(206) 433 -1845
Work to be done T.I.
,Site Address
Building Use Office /Repair /Warehouse
property Owner McCann Construction Company
Address 950 Andover Park E., Tukwila, WA
ontractor McCann Construction Company
Address 950 Andover Park E., Tukwila, WA
95U Andover Park E.
BUILDING PERMIT
PERMIT # 7 S
Control # 87 -175
(513)
Suite # 12 Tenant Tandy Corp.
Assessors Account # 262304 - 9105 -0
Phone # 575 -4330
Zip 98188
Phone f # 575 -4330
6o
4
Zip 98188
//
FOR BUILDING PERMIT ONLY A.proved for issuance b : / / ♦r/� v
S q •
Warehouse
Retail
Other
Occ.
Load
1st F1.
1864
410
2782
B -2
32
2nd F1. J
Total
Fire Protection: [ Sprinklers C1 Detectors
Zoning c_h' Type of Construction
Special Conditions
Fees
sq. ft. @
sq. ft. @
sq. ft. @
sq. ft. @
1st F1. $
2nd F1. $
other $
other $
Total Valuation of Construction $
Bldg. Permit Fee
Plan Check Fee
Demolition
Surcharges
Other
Other
TOTAL
40,856
Receipt #'74o1- $ 356.00
Receipt # 7312 $ 228.00
Receipt # $ 1.50
Receipt # 7602,$
Receipt # $
Receipt # $
$ 585.50
FOR SIGN PERMIT ONLY
J Permanent [] Temporary
[I Single Face J Double Face [] Wall Mounted J Free Standing [ Other
Building face Setbacks: Front Side Side Rear
Square Footage of each sign face Total square footage of sign
Special Conditions
1HIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED l5 NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR
ABANDUNLU FUR A PERIOD OF 180 [JAYS AT ANY TIME AFTER WORK IS COMMENCED.
I (HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS ANU ORDINANCES
GOVERNIN TYPE OF WO WILL BE COM IED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DUES NOT PRESUME TO GIVE AUTHORITY TO
VIOL AT NCEIL TH PROV ION$ O► ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
Signe ( 5
LICENSED CONTRACTORS DECLARATION
is1ons of the Business and.,/rofessions Code, and my license is in full force and effect.
Date 5::-,2R_—_627
OWNER - BUILDER. DECLARATION
( ) I, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or
offered for sale.
( ) I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project.
Owner (signature) Date _
I hereby affirm that ice
Contractor (signature)` C^
ITY OF TUKWILA�.
'Building Division
6200 Southcenter Boulevard
Tukwila, Washington 98188
(206) 433 -1845
ork td be done
ite Address
uilding Use Office /Repair /Warehouse
T.I.
9bu Andover Park E.
BUILDING PERMIT
PERMIT #
Control # 87 -175
513)
Suite # 12 Tenant Tandy Corp.
Assessors Account # 262304 - 9105 -0
Phone # 575 -4330
Zip 98188
Phone # 575 -4330
Zip 981b6
roperty Owner
Address
ontractor
Address
McCann Construction Company
950 Andover Park E., Tukwila, WA
McCann Construction Com an
950 Andover' Park E. Tu wi a
OR BUILDING PERMIT ONLY Approved for issuance by:
S Ft.
Sq.
Office
Warehou/
Warehouse
Retail
Other
Occ.
Load
1st F1.
1864
410
2782
B -2
32
2nd F1.
3rd F1.
1
Total
Fire Protection:
Sprinklers 1: Detectors
Zoning y47f `..TYpe of " Constructfi•oh_.__._
Fees
sq. ft. @ 1st F1. $
sq. ft. @ 2nd F1. $
sq. ft. @ other $
sq. ft. @ other $
Total Valuation of Construction $ 40,855
Bldg. Permit Fee
Plan Check /Fee
Demolition
Surcharges
Other
Other
TOTAL
Receipt # 7I-x_>•4 $
Receipt # 7312 $
Receipt # $
Receipt # 7Co2.$
Receipt # $
Receipt # $
356.00
228.00
1 0
Special Conditions
FOR SIGN PERMIT ONLY
EJ Permanent J Temporary
[[ Single Face [( Double Face [] Wall Mounted [D Free Standing 0 Other
Building face Setbacks: Front Side 'f' Side Rear
Square Footage of each sign face Total square footage of sign
Special Conditions
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR
ABANDONED FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK?IS COMMENCED.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES
GOVERNINp THIS, TYPE OF WO K WILL BE COM LIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO
VIOLAI OR C NOEL' .THE ,PROVISION pi ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
F{ .y.•
6/ -5?
Signed. '?s,,.,. C•� . %L...- L .�..'�t„- Date f) ..r?
JS LICENSED CONTRACTORS DECLARATION
hereby affirm that;I am l.icepsed nder.proyisjons of the Business andlrofessions Code, and my license is in full force and effect.
Contractor (signature)-lat. (74. • 7.�' < (1—/,'1%—_ CLC,\liri• Date 5 -a2Cf.7
OWNER - BUILDER .DECLARATION
( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or
offered for sale.
( ) I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project.
Owner (signature) Date
lemin ffYJ.ott r x 1VolltsMiatUnaGlJ.`fk wi. N.:
• CITY OF TUKWILA
Building Division
Tpkw ili, Washinotonui98188
(206) 433 =1849
Type of Inspecti n FiraiD
Site Address C(5 .) P6 E
Requestor (43/ CQAJL
Special Instructions
INSPECTI °1 RECORD
PERMIT # L475/
Date %`,.O'87
Date Wanted -7--F7
Project a
Phone # oS%5 336
Inspection Results /Comments:
crtiz°
Inspector / �(/' ivu. /e1-)
Date 7/.. ' %!7
CITY OF TUKWILA
Building Division
6200 Southcenter Boulevard
Tukwila, Washington 98188
X206) 433 -1849
.. kworw +ow+zn4�v.tnw «irnu:suv�e�a+wcuv
Type of Inspection et0/ , G-<-/ d
Site Address 25 ,9i i,/ ve - /61 js&
Requestor
Special Instructions
07-257
...,,wn.wcvr.+ma�waieY 'tl..'v4fi
INSPECTI ., RECORD
ti'
PERMIT # g7.57
Date 72077
Date Wanted _7/2 7
Project /.95
Phone # _575- y..330
a.m. p.m.
Inspection Results/Comments: �i.�
ul�
crn 1 -
1e-1 Gr' Le
Inspector
I/044 „4,44.9
Date 2:///25//47
r m it F rxttPnru
CITY OF TUKWILA
Building Division
6200 Southcenter Boulevard
Tukwila, Washington 98188
(206) 433 -1849
Type of Inspection
Site Address
Requestor
Special Instructions
9s-0 4-
Mw).Y VAYIiH
:or/. /.._.r.■04',.
r
Vti
�:,rrre�s.,•,,�:�hr �'r.+iu?eK4r+
INSPECTI 4 RECORD
PERMIT # 4/75-7
Date 7— 2 "b'7
Date Wanted TGf7w, 7( 3/ 7 a .m
Project /*/24
Phone # .s' 73---5/3110
Inspection Results /Comments:
Inspector
Date '7' 2,3 47
- nu ,,irshmtit.:'t41161 ::T∎laaele. 0,V.,:it%4t'R'atl�t
NL xYkw!6ti.:
CITY OF TUKWILA
Building Division
6200 Tukwila�tWashingtonu198188
(206) 433 =1849
Type of Inspection
AI
l'eplitl
M6+1. U1Y,11 .41Wk4,41,,,,:.*MtSfAtti...1 1,,,, ,*Wm... .ran.. «., /....i )t!.41. Vfill/ Vii9e' i1.1.1t O: '..., ,
INSPECTI
RECORD
PERMIT # 4(75-1
Date 1 -- / G. --1/7
Date Wanted i X7p,m,
Site Address 95-6 Pk. �=, Project z4
Requestor c''74d Phone # S 7 Sy3 c1
Special Instructions
Inspection Results /Comments:
lif?
Inspector %✓1���
Date
7//7-/sv
CITY OF TUKWILA
Building Division
6200 Southcenter Boulevard
TukwiTa, Washington 98188
(t06) 433.41849
Type of Inspection ii—)'aA441 4ty
Site Address ASpu -PY" ,3
Requestor YYy
.... r ,n�rs'.xt��r• "a11n:'a.:.:l,Yio"
INSPECTI N, RECORD
PERMIT # 21/71S-/
Date V/3/7 7
Date Wanted 7//9
Project -514%
Phone # 575 2/370
77
Special Instructions
Inspection Results /Comments:
i
• /
/ !
. Lam
Inspector
Date T707
CITY OF TUKVK . _A ,Arol No. 97 — /75-
Central Permit System Permit No
FINAL APPROVAL FORM
TO: ❑ Building
❑ Planning
❑ Public Works
Fire Dept.
Project Name /► / r --
Address c ?� .V4 /c &-; C
Type of Permit(s) 7 /
❑ Police
❑
Parks/Recreation
1
/
This project is nearing completion. Please investigate your area of responsibility and indicate
below either your final approval or necessary corrections.
If no response is received within one week, it will be assumed that the project is of no concern
to your department and a certificate of occupancy may be issued.
project is NOT approved by this department; the following corrections are necessary:
) e-
(
,6
Authorized Signature Date
This project is approved by this department:
•
Authorized Signature Date
CPS Form 3
eoUSPE1417GD
AGGeOUGrrrlCGAL
LIN 6, Tom:
+71- 04
'LNG wood '00-rtibw(oR
. • MGTe64- - SOW., 1: D N
Tlatti Tom 'rrno r4)
14" U.Ci, rvLL rimici n-
w/ MUb PL.ATG 154,411T-
W.4 04, "r0 GL!)•S.yiei
(Aw •NLecalpl✓ PUu.
h1E. Chh'!T.....
G114 (.1r. i liii'�dltf�
f PFFAO \i D
• MAy 18198.1
UOTLU. ,
C !VIsTo
Oj' - d�
LOG1cING
q' -ON
- Na-rm
Flat-c,coURG TRCATED F'I.,A-r ".
IgA,- reri D'Ta e•4NGRE.TG t^;/
RrrMc r--r • ?IMO Oft pct A$ . ( 4.1.d
O. G. Isi AGGOF •CIANGE. w/ IGeto *144-7
(4.046 9i4," 1 W DLR 7RVer1
I r�L.w w z 0 I+ I r N4
g#1. 04
OR •>ji4.'' Vs.64 1-1 . )
RECEIVED
CITY OF TUKWIL A
BUILDING Oleo'
Tyr.' TE_NANT bE..M IZI NG, WALL
4ALE. I i /,i:
Ipn
Architecture
Planning
114 Vine Street
(2nd «Vine)
Seattle, WA 94121
(206) 724.5771
Project MG (..AcNNI /TD' n
Subject WALL ssc>IONS ?se. C.try of TUKWILA ZEIROEUT
PraeCtNo. 84024 Date 6 14.84 By WSW
•
I. I
C.m.11-11-.4c4 -r•(1:1:
2.04 4,TUcue Coca. MMTAL
G4aor•47F4,4sc.:r0Fa..e2 .010•Tiot.4)
c a. G. v-i/% 6W.
-TYP: INY1ri ALiw,
cilY
M
1)1. UKVltI
'ROVED
1 8 1981
Gf WE? f‘UL.L. riv-4c1lT
WAlt-t-r+c)ucze. a-aloft
012.
RECEIVED
CITY OF TuKvvILA
'.•!
BUILDINTII. tem. •
NutED
iif51.1"IG r)t\'tS()N
ccJA R- e-I-10 u c., WA L L.
Le.
"T‘M
1pn
PrOied Nela•Itht4 trAt•41,f
PriChn•CiUre
Planning
114 Vine Street
(2nd & Vine)
Secs, WA 96421
(206) 724•5771
Subield
A_ .
• . zor
Floiscstio. BR-0241
Date Sb'IA 8-+ By 1,4S.VI
1
I (fir IY 0' q.y
VVA
Transmittal
To: Duane Griffin
City of Tukwila
Building Department
6230 Southcenter Blvd
Tukwila, WA 98188
Attn:
Re: Opening in Panel
Description:
2 Copies
I NAY 2 9 1987
Date: May 19, 1
Project Name: McCann Construction — Tandy TI
Protect No: NW 87 02 4
Stamped Engineers data on structural needs for openings
in exterior wall.
P1 -3 Elevations and tie details.
P4 -14 Structural Gales.
Remarks:
Sent per your Request
❑ For your Use /Reference
CFor Review and Comment
❑ For Approval
❑ For Distribution
❑ For your Records
❑ Other:
By: Katherine Wright
cc:
ENGINEERS—NORTHWEST INC. P.S.
6869 W000LAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525-7560
Joe No JOB NAME /IC 6 ■,') I IT., ",' is I —A,
DATE /13I87
SUBJECT SHEET Cate OF
BY
77 I. CALevi f/0,./S
• 44041100 el Tit Per4aLS rigo 3
Sigveri/x4I C/Vevi,11/04/: 1.4 7447 14—
.1-111[1:1101\YIN.*0
\MAY 20 1987
CI I y
CITY OF, TUKWilii
./ki'PROVED
•MAY 20 1987, .
A t ED
TUri..T51 NG DIVISION
• 1,1
1 5 'i987
YN -Architects & Planners
JOB No
ENGINEERS-NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N. E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
JOB NAME //Ir `t.9 .ct DATE 512/87
SUBJECT SHEET L OF
i
BY /10,7
4. -241 % " ( 1.1/1E
2o'- 0
1
bi.•1 c. ','l 4l �4. 9� e(70
0
Ao-c
t -.
/
5idaSG't65
Wrsr)
New 7)E
A/t W 7/5 #2
.20'- o'•
5' /8X/5 CC8
/s-)
EX,s1 5 X30 4°GS(Iyp)
4--
=,
• ' 8'-o".? 170r.
Er-
4xib -fir
( lsr)
fog
7 %0;
L3.bt
1,3 1-6't
Cur &a IN tor
(itizipy All D /MENSiovs) (H )
D"
/016-41 /1'& W T/f oe
0
1
4X/�.�'__
.1o: p"
Gil w /n'GbW /N east
aE,i cy 41,4 O /HE 5oNs)
N6w Tie *3
/Je kl TlE •6`3
co.i'*7ae YE/Uly
S/, s ,Pr
xisc[3J'
(k4 /57)
S/f ov 31434 Sr49, 4NCNoR
514 $105 (LX/sT) -- CoNr1•,c7'o4
VcoiF'l e
yERIFy
size fl
5T
I)
Nbk
115
*4
I'Vs cur- /l .1
TA/6.
ENGINEERS- NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
JoB No. JoB NAME / %ii r��'�, ,P19 G=r .947 I r/v/D1
SUBJECT,
S'yirsaV HD 5 ER 5 /06
wf yt'i, 7NA'E0 ROD
6e •
DATE 1/07
SHEET Z OF
BY ,VGP
6Q
51/8x1.5-41B - Ek�sr
<—\ ifs( 30 Gt8• cx/S7
067,1I1 - /116w. r/E a1 04":41-o''
.0':
•
2
11
ENGINEERS—NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
JOB NO. JOB NAME P.. cr 2d /d ?JP DATE /gyp / ✓7
SUBJECT SHEET 3 OF
BY /COQ
�(PA/L
• ' , •
" 9''
■
(/Nii Ma)
-
• s
Z
dI - --4x11 HDZ
r
14116 sr 4p w/ 4.718'/ £oIrs ro 4x /b i
1I 3 3/q f4 4 rs (4'Ft' ) 75 A. y
I TMlL -- NEW T/E 3 (," I -d)
e Nstx View).
-tris1
6z
.ul (y/51)
7"
11
li wiav �n0 r� 4G8
'1
n 711
��1 J BD7A Wiz-3/4! puolfs
. ,1s sHm✓N cp.),
067411 — N6 W TIE #L (% '1:01)
(7,
ENGINEERS - NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
Joe No. JOB NAME (2Jwi1 , 7.7 Ti, ✓ i DATE VII E',7
SUBJECT SHEET -I' OF
BY /'1''J
E;.- -t-'3 . ^r. ,45j 7 (.? / 1 • We! J
..,c•.rt
Sc fir' X415 :M.
15.913'3 �.:•Z
4y7�' SWrIFr >41S f f
21170 Rlo ln. 415
5•o111.1 ; 35111 44zs
•4.,N13.11:.21"4 ¢1S
(751 '844 Iv)
273"11i z47S
ihko
87'5
1'
97.5'
P0I1 29z :Soo
O175�1/�
s'ft
Iz1 •S
t)O L � -�
- •.
. �+� r 40.1
1ZJ' N- rya
7,91
iID! X 11 911r1' /N 314414014.
4Io.'4& : Zits° .5o lrT
j
I
O
N
Too : 372t i •
Litt Law
25'o
DIo two
PGA £ dt,: S'0
&UI;oor ;'2
76.'ayo 18
.2X4s @a4.'J{ 0.1
4XIbi�B.o 1.8
6Vz3000.201e. 2.5
4/501• 0q
Aka I 'o
sP1,04/ :RS 1'5
Calmly l' 8
Mae o'S
►1.5 p5F
NSCR�M /I XSS' t t 7 '9101
, 5 /eFilwoo h8
axis ®24"oc 0'1
2s4s@ 4g•"c 0.4
louul, wr. t glog9 -- 224
Wivv p : <.e, r
= 0'7 xl.3Y 17
Is.sr
clamp ,
SEISM( : x:0,4
19
ENGINEERS— NORTHWEST INC. P.S.
6869 WOODLAWN AVE, N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
JOB NO., JOB NAME "[ !• // il.A!:' 2 21/0 u DATE $/6/$7
I J
SUBJECT SHEET 5 OF
X00
A)
19.►
4I
2..75
I'!
I5 l'3,' 4•ZS
-11 -j 10._.._41
;
,•- - - -,
it 3
y
0 ICD ( l! L %
.26•S .24.l l /9., 0.149
2 •'4.'7S o493
3 ,20.O 0.156
I11 4. 00 0.078
5 /0.0 0 078
14""'S 0.191
# 1c ij .s .s. 11 7 7 .W.1 0156
2) b0 412.
4: 0'
,0.0
za n = 0 29) 94.
4: 0.3/8R
T5' 0.467 -Ph: 6.655
b,uti I,lt 4 /v , 2 o9q
3.'isa.
,b7 1432
3 &k10 Qc' 0.628
.to : 0• ;t5 a 4 0.111
V = 0.517
65 /7; o•9zt IF: 2.7:6
61";161/if: Dr 6.29(0
/28.45 boot
L
I 19'1
d¢3 4415
4 /o
5' to
(4i $L
120'45
1 /9'/
3 -►
4 10
S /0
6 14
BY
/0
hit gc
to .11c 11445 0.144
o :763 2'43o 0'241
319
o.9So I •s93 O'I58
11,) 6.302 0'03
/.9) 0.3o2. 0.03
6716'
2. 383 0'237
0'945 1' 611 0'160 341
fR: lo.pj, I'e00
R
0.149 0195 /.445 0. o78
6.34-3 0'425 6,3n 6'431
0.078 /1) 0.102 0021
(n73 1.90 0.102 oq1
e3d7 o'4w 6.301 0429
1,000
,6 2 .00)
0 etas I'445 0'209 z C7 : ►a,
2.314! )'334. x L-' : IS.
1.230 0,11$ X Z77 • $•.'
I. 0.302 0'044
I' y 0.302 o'044. I< 4 : 2'
1'351 0.743 0.104- k �- 7 . S''
ENGINEERS-NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N.E.- SUITE 205 - SEATTLE, WA 98115 - (206)525.7560
Joe No.
SUBJECT
JOB NAME �'�ir�ii 4', -.
J •(s;.
/9.1
J.
J.
a
4-
S.w ti2°I,sC.
0/po (4440
RM �Sv) d9 S� I a ' 4,$2 K.�r
_ DATE
SHEET
BY
I 1 .
OF
s.w : lq )q ./ y 5/.' ; 45k
xo•ic t 4,14
ENGI EERS— NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
JOB No.
JOB NAME
PO.
DATE 5 / /B7
SUBJECT SHEET ' 7 OF
BY /y00
- 7tV., r 51.11 ? '"
•16.1
^o•IC : 540.
Piro * 2 agr
C
a41
16.2 r
rs'
`1 9 .
0TM Q5.09 X(134.) CS•I Y1`1): 331
i
19'4
z 441�.Fr
(91.2Dx 11`S
t 0451,7
9.91`
4.3.75
1
ENGINEERS - N WEST INC. C. P.S.
ORTH
6869 WOODLAWN AVE. N. E. - SUITE 205 - SEATTLE, WA 98115 - (206)525.7560
.JOB No JOB NAME 11 1!1 i an, NO DATE
SUBJECT SHEET
Pitoi 4 3., utta4L BY M00
58"
a of
1,01
DPI ; 18,r y ig.q,, + 1 X A.L ; Me'F 7
266K 1
Rti ..2�'cx l�
rt
10'
r
9'4
( fowl-
S.■
Logy I 1 . 81.15, 3o,"
31 2j 5 3.
2v'
oIC 3.74
64"w'd4e9 kW.
ID( gq.x64'. SO'S
S11.1•614.r% 651t
/1,144 rd.,N11 c 3131-
SNc A>o c./•
ENGINEERS- NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
JOB No ..108 NAME ��NAII C� ,2iL 7.ii f DATE 5/4/87
SUBJECT SHEET / OF
PjN14 4- BY M00
S.$4: lo'xi9rB i.'2 ,s•a`e
t 244
(0
s•4: is•ak •
or?1: C v/c(84F)(nx9.Z 58.4 "r'
RM
0S.4.19.9) s
/26.5
..os No
ENGINEERS- NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N,E. - SUITE 205 - SEATTLE, WA 98115 - (206)525.7560
JOB NAME
SUBJECT SHEET, ' /0 OF
PAW] 4 5 l- 41L(41 BY MAO
S.w: Nsr11XQP2S. 21,e.
$0I4 : 3.0"
oTM ;
(PISA) (x9,z) z 11541(11.
RM : 2I.1, 0' 411., %4): 19/141
'94
ENGINEERS—NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
JOB No. JOB NAME V 11 i' Cr • ' . NOS DATE
SUBJECT SHEET H. OF
PAC Dreg! BY "10D
/3.1'
424
k.
orM; (4.2xI844) «.3119,t) /
Rtl
ao•t �y
3
t. /33 K.r
S.w : /34)09' xelaS , Z. 24
XOIa = '"
EN6ft1fEKs NW iNr., C0( ;I :RFTF .IAMB DE1;I6(I Iversinn 2.51 Sheet /2
6869 N00DLANN AVE NE SUITE 205 05 -07 -1987 PANEL03
SPattlp ;ka ;hinntnn 9!111` 0;';53;75 MC.CANN /247 /TAIf)►Y
po 100
JAMB DOA hp;nht (4t) with (in) th :cknpSS (in) add thickness (in) K factor parapet ht (ft;
18.40 36.00 6.50 0.00 1.00 0.00
SPANDREL DATA thirknpss(in1 of4sPt (in. 4 outward)
6.50 0.00
OPFNIN6S LEFT width (ft) hPinht (ft) R16HT width (ft) hFight (ft)
10.0 9.0 0.0 0.0
MATERIAL DATA cnncrPtP (psi) rPbar (psi)
3000 60000
IOADINO DATA unfactored
wind in (p;f1= 14.3 nut Ips41= 13.7
seismic... zone 3 press (psf1= 36.h import fact= 1.00
IPdnvr 11 1p141= iI 81 (p141= (1 prr (int= 0.0 i II w /aaiarir= 0
cnnrentrated had 1.1(1h0= 14100 01. (ihs)= 9900 err (in1= -3.3 % LI w /Seismic= 0
rnrrvntrtr Inad (1 (p141= 11 01 Ip141= II 1 (1 w /splamir= (1
hnriz Inad plf If inward!= 0 dist above flnorlftl= 0.0
RFDAR OA1A
VPrt;ral 4 14 r1= 3.95 Hnr »nntal min in^% / ft 0.16
MOMENT AND DEFLECTION RESULTS + inward outward
Ease Pu (kips) Mu fin -k1 PhifMn (in -k) defI (in) A11ow defl(in) Comments
1 4.8 27.5 51.93 0.12 2.21 case ok
2 4,8 -24.1 51.93 -0.11 2.21 case ok
3 4.8 29.6 51,93 0.11 2.21 case ok
4 R,6 30,t 57.86 0.17 2.21 case ok
5 8.6 -24.4 57.86 -0.111 2.21 case ok
6 5.6 30.3. 53.26 0.11 2.2! case ok
7 15.4 0.0 66.90 0.00 2.21 case ok used interaction curve
LOAD CASES
1) .901 + 1.3WL inward
2) .9DL + 1.3WL outward
3) .981. + 1.43E8
4) 1.050L + 1.28LL + 1.2(1NL inward
5) 1.0581 + 1.2811. + 1.2881 outward
6) 1.05DL + 1.28LL + 1.4E8
71 1.40L + 1.7LI
INTERACTION CURVE DATA
.7$Pn .711Phal .7tMhal .7tMn
111.4 23.8 R5.7 33.5
NOTE in cases 11, 21, 4), and 5) the
LL used is 1/2 of the applied LL
ENGINEERS-NORTHWEST INC. P.S.
6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525-7560
Joe No
JOB NAME
llt
W
DATE %/1
SUBJECT SHEET 13 OF
BY 't:
atri
aJ l�
S._.
1
r
_ 61.5 j 42$
87.S.
%ITS% k 81.5'
VI
20'
• r.
.43
/ 4
g? p E"£•5
•
,• .
JOB No.
ENGINEERS— NORTHWEST INC. P.S.
6869 WOODLAVJN AVE, N.E. • SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560
JOB NAME
i/
/'j 1.0"I,:.I .%!.' 7 /ii. DATE 5//3/i'�7
SUBJECT SHEET /4 OF
BY />0)
/41,7,41
c
• J
f
.7
L
o . 4.7'7
47`x_.. 10.0 )0'0 ,I1 20 , 43 4; 3 a.o� A: X01
. /3.0 .34.'7
,,
. 37.8 :z.'.... 159 i 2> • 18.4
-2-9.3
d • 22'8 .t4'9
►� 4
• '2'9 1 ZZ'S
_3' .2.1 J 1� .7.1.1 120 b
/1'3_ ;3',,,..— .211...�1= 1' , 21.
• 16.4
i) • • 1 • 16.3
. 33.6 . 14.1
4,2 ... '6 ._5.o. ,jr 1; .3‘.9 •1004,
k: 1.7 39,o
d. ,9
q.•2 4,2 •j u .43'4 • • 4-3
b , 4-►'7 1 0
471'x,
Ito.
101' gyp,:; /off
�f is
V
1184
` 224
'1.;2.1c
-I 3.11P Au litd
l' k aili
. ) IK
4.
T'1.
ir
:,11'1 7 13�, i
lid 2.t41
2.I a 4:1
41
9.411 111;. ,,Ala 1.11!
c �
yI S' °1 "s'h
3.1"
TIE
City of Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
Hubert H. Crawley, Fire Chief
Gary L. VanDusen, Mayor
May 14, 1987
Fire Department Review
Control Number 87 -175
Re: Tandy Corporation - 950 Andover Park East, #12
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at, one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10 13:C) dry chemical type.
Travel distance to any fire extinguisher must be. 75' or
less. (NFPA 10, 3-1.1 and UFC 10.301b)
Extinguishers shall be installed on the hangers or in
the brackets supplied, mounted in cabinets, or set on
shelves (NFPA 10, 1 -6.6), and shall be installed so
that the top of the extinguisher is not more than 5
ft. above the floor. (NFPA 10, 1 -6.9)
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher ", with an arrow pointing to the unit.
(NFPA 10, 1 -6.3)
2. Exit hardware and marking must meet the requirements
of Uniform Fire Code Sections 12.104 & 12.114.
s
City of Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
Hubert H. Crawley, Fire Chief
Gary L. VanDusen, Mayor
Page number 2
Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort.
(UFC 12.104b)
3. Maintain sprinkler protection for all enclosed areas.
(NFPA 13, 4- 1.:1.1)
All modifications to sprinkler systems shall have the
written approval of the Washington Surveying & Rating
Bureau, Factory Mutual Engineering or Industrial Risk
Insurers, then by the Tukwila Fire Department. No
sprinkler work shall commence without approved
drawings. (City Ordinance #1141 & NFPA 13, 1 -9.1)
4: All electrical wiring is to be inspected by the State
.Electrical Inspector, Washington State Department of Labor
& Industries.'
5. In order to provide you with the fastest police and
fire protection under emergency conditions, please post
your suite, room or apartment number in a conspicuous place
near the main entry door. Numbers shall contrast with
their background. (UFC 10.208)
Yours truly,
The Tukwila Fire Prevention Bureau
cc: T.F.D. File
nod
CITY OF TUKMiLA
Building Dlvtsion B i►.r SING PERMIT APPLICA'''ON Control l75
6290 Southcenter Boulevard
Tukwila, Washington 98188
(206) 433 -1845
Site Address SO /N,no . ` ANcex. t=7V4T Suite# 1,2, Floor# �.
Project Name /Tenant TANtor c oz'o r c rt ((ompu-- bv)
Valuation of Construction �{•p) g Assessors Account#
Property Owner Ia (,.,,, (o (p ,„ y Phone
Address ctE AN., Dov2 qua
7 - Ti,�kLU►lln ( �-
Appl i cant L. .? j4 - - e-r . 4 Phone
Address I 1. \J' i Ni e WA-
Address V ) S F lJA Zip ciel2I
Zip 9A188
Zip cifa, i21
'7Z-8 t
Architect /Engineer LPN 'pljk r„.a_ts Phon e
0
Contractor c �ph.,N �7 -{ . License# 22?, , pl Aft . tip , Phone 5 49_3n
Address qSU DQV, I 1.) (Ax& Zip `1,6P36
Class of Work: D New C1 Addition 12rTenant Improvement D Remodel (residential)[] Reroof
El Demolition El Interior Demolition 0 Other
Describe work to be done T. r, 5109 aQ a cols) is-h pr•rv,
ll
• •■
i yr
2_
e of Const. (UBC) vim. -0-cc. Group (UBC) 0.f -7fRci,
Square footage of entire building .4(, <illEE,60 Square footage of tenant space___422A§dtLlr
Building Use c -r'icG Will there be a change of use? 0 Yes:11R No
If yes, describe change of use, including square footages of changed areas
Will there be storage or use of flammable, combustible or hazardous materials on the premise or
area of construction? 0 Yes ErNo If yes, explain
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND
CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK.
Applicant /Authorized Agent (signature) C__ -��� -- Date G,> '.c)8 'g (print name) I- F M A\p_c_t-i-- rfEc -- 4 PI-Pn")"QaS
Contact Person (please print) v.-) ____ Phone -9-2
-�sra�iIL3er:�` li -5
OFFICE USE ONLY
FEES: Building Permit Fee (000/322.100) $ .3.5 6• oo Receipt# .7C,O -Z Date Paid s -� ' -s 7
Plan Check Fee (000/345.830) 2-2�.o6011eceipt# - -.pate Paid 5 -g.-p7
Bldg Code Sur Charge (000/386.904) 1.50 Receipt# -76 6-,.._ D'at- Paid 43--.2-5-S7
Energy Sur Charge* (000/386.907) Receip Date Paid
Other ( ) Recei # ` Date 'aid
- 3.00 e—. cic-
*New construction only TOTAL (0 'S: $ sz sa
)
a. -
SQUARE FOOTAGE /BUILDING USE INFORMATION Square Footage of . LBuild'
' 3(,o
g--)
,
FL00 USE Occ T :
S .FT. SAD USE Occ T :
S .FT.
rr
LOAD
USE Oc -
OCC
s!I
1 �i���
' L
OCC.
bt • 4.4317�l47PAWA
1/L'�V it CPP
U
7
, , _ar
inns
NA_
Mat) Wilfaiffel
I
. . o . i .4
TGTA
.......
.._..T....
TRACKING
DEPT.
DATE IN
DATE OUT
COMINTS
BLDG
e��1
\�J 1
S /jc,g�
Approved for Issuance i Type of Const.
To N,21/4-4-at C' Date pae_eCZ46-Cclxv 5.-/3 °g7
FIRE
��rt
\i�Q
•Or
3(6, 1
Approved (Initials) Per letter dated ,, /�►
Fire Protection: cj3Prinklers 0 Detectors S�Y3
PLNG
Approved nitials)
• BA' ❑ L'N, U " "'"-.-- 01 IN
Zoning Setbacks: N S E W
Parking stalls required for: Site Tenant Space
Parking stalls provided: Site Tenant Space
ADDITIONAL PARKING STALLS REQUIRED:
PWD
Approved (Initials) Per letter /plans dated
PQPvp.
'17�1A/�t,•
1'hit portion of the southeast quarter bf the southeast quarter
:1 %'ibf Section 16, Toirnehip 13 north, Range 4 east, W.H. in the
is 'C,.lty, of 'Tukwiln, King, County, Washington deecrlbed ae follows,
. • r
t.8estnning at the northeast corner of the southeast quarter of
j.d Setteion 26; .
ee So2'22'20” U slong the east line of said southeast
, quarter A diotenee of 1319.71 feet to the centerline of
:;-,the P -17 drainage. channe }; Which channel continues
§88.12' 32 E • so.-tgigsdnue. ab; Rho westerl_ mer in of
'1►-- ..-- .a.....ra,#t- sit.- - -.5'� •- - - - - - �-- 'r'*'._....... _........ ...� ...�.,__ ..
�Fsteneen Roadf:
GOAT K
ce R88'ltr01" tt atOng the said P -17 drainage channel
enterrl'fne 9I2.43'. t.et;
�
ence. '$1•47'2# W 1L.Q0 foot to the true point of beginning;
•,>l'hence ;tontiuuing'$01'47'28'% 297.59 feet;
-$ b 9o. $84 °12'$2 "0 297,00 ,beau to the easterly margin of
AnA,gauer Park Seat as. reeordGai Under Auditor's isle No.
2T4#44$30, Volume 5005, Pages 65 and 66, Records of
''Pennty4 Waehinjtoo;
No1 °47'28" ltr along said easterly margin 297.59 feet;
. Thence 588.12' 32 "E 297:00 feet to the true point of beginning. .
;s r
,.Subject to and including an easement for utilities over the
north. 15.00. feet and over the vest 15100 feet erevf;
-.
►4 ' $ubjelet to and including as easement for rei.lydad 'purposes over
1. the 'meet 27 feet thereof.
0.
l c# c;;et7
TaiI.ET e.T
cavE ow el -rzeR
ELEVATION
TYP. TOILET
LEGAL DESCRIPTION
1. All materials and workmanship shall conform to the 1935
Uniform 9utldin9. Mechanical and Electrical Codes and Local
Codes or most recently adopted edition.
i. Typical details shall apply where no specific details are
given.
3. The Contractor shall verity all dimensions, elevations and
conditions prior to construction,
4. All dimensions are to take precedence over scale shown on
plans, elevations, sections and details.
5. All exit doors to be operable from lrmide building without
keys or special knowledge.
6. Work related to tenant improvement and required coordina-
tion to shell construction shall be determined by the
General Contractor for bidding and contracture] agreement.
7. Walls are to be firestopped per UBC Section 2517(f).
8. 'Nose stations shall be provided per City Ordinance (loca-
tions to be approved by City prior to installation).
vau�T w. H.
c1,+
v�5�
9. Fire extinguishers shall be provided per NFPA #10.
10. Doors without door type numbers CJ are included in
building shell construction.
11. All interior well covering materials shill be fire resis
tive or shall be treated to be fire resistive, so as to
result in a flame spread rating of at least Class III for
General Areas. Class II for extt:ways and Class 1 for
enclosed vertical exitway. Deliver certificate to the
local Fire Department.
12. Revise sprinklers according to specifications to include
office areas.
13. All equals to be submitted to Architect for approval
prior to construction.
14. Bid design work to be approved prior to construction
✓Ue),AT-re✓ Pte. - :_i!P&
ACT. ACOUSTICAL TILE
F. A.F.F. Af30YE FINISHEI) FLOOR
AL. ALtli'iIN1N
ASPH. ASPHALT
moo. ANOOIUO
B4. BEAM
BO. BOARD
BLDG. BUILDING
CL6. CEILII,]G
4
COL. CENTERLINE
CO L tMN
CA$C. CONCRETE
CONST . ODNSTRixT I ON
CCNlT. CONTINap�
D/F DRINKING FOUNTAIN
DTL. DETAIL
DIA. DIAMER
DIM. DIMENSION
D.S. DO►4NSPO;FT
DR. DRAIN
DWG. DRAWL G
ELEC. ELECTRIC
ELEV. ELEVA� ION
ENG. ENGINEER
EQ. EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
FT . FEET
FIN.
FLR.
FTG.
FDN . FOFFFLLIOO
UASR HS
AU I
N
G IO
M FOOG
F.O.F. FACE OF FRAMING
GAL V. GALVANIZE
GL, GLASS
G.L.B. 6LU- LhMINATED BEAM
GYP . B0 . GYPS t) BOARD
HDw . HARDWARE
HGT . HE I
N.M. HOLLOW GHl METAL
INS.
INT.
JT.
LAY.
AFR.
MATL.
MECH.
MTL.
MIX.
N.T.S.
N13.
INSULATE (INSULATION)
INTERIOR
JOINT
LAVATORY
MANUFACTURER
MATERIAL
MECHANICAL
METAL
MIXTURE
NOT TO SC "I'
NUMBER
OFF. OFFICE
0.C. ON CENT i R
OPNG. OPENING
PNL. PANEL
PTN. PARTITION
PLATE
PL. LAM. PLASTIC LAMINATE
PLYWD. PLYWOOD
REC.
RECP.
RE I NF.
RF.
RM.
SDG.
SPEC.
STD.
STL.
STR,
TEMP.
T.
TYP.
U.O.N.
V.A.f.
YEW.
W.C.
W.H.
WO
RECEPTION
RECEPTACLE
REINFORCING
ROOF
ROOM
SIDING
SPECIFICATION
STANDARD
STEEL
STRUCTURAL
TEMPERED
TOILET
TYPICAL
UNLESS OTHERWISE r:)i
VINYL ASBESTOS TIL)
VENTILATE
WATER CLOSET
WATER HEATER
c-TIN
X2 ' 8 5F
GENERAL NOTES
ABBREVIATIONS
ALL E f ECT , P Lthrl 6-A G IYI ECm (iO & I G JiE
L.NDE SE?fAnTE. PERMIT.
LAG :,�► -It`J G I�:E
EX
t 9 'F
✓xlr rl 1. ��I
1514. f✓
FIGE
IciR.P
EXISTING BUILDING DATA
'" : �-*`� -✓ �'- - - V -N Jkl f -O
C ci f rlV J' - e-L
P'r 12,
4(WOA ' .
-VIAL/ cro_cq
SHEET
T -1
T -2
My OF r(}Krlsi.[,
APPROVED
MAY 18 1H7
DESCRIPTION
Project Data
Floor Plan
FILE COPY
1 understand that the Plan Check pr ovals .-;-
subject to errors and era °,ssions and :pprov;,; c.(
plans does no; auihcrizc the violation cf any
1 adopted ,..c:d or ordinance. Receipt of ci •,itraclo
(copy of ap i cvsd plans acknowledged.
13
Da°3
1.........
2: (
KEY PLAN
vamommormsmberrsimor
Existing 2' x 4 Troffer
let
Duplex Outlet + 12"
1101
Proposed 2' x 4' Troffer
Existing 2' x 2'Troffer
Proposed 2' x 2' Troffer
Recessed Downl i ght
Slot Diffuser
Floor Mounted Outlet
O
ER
Telephone
0
Floor Mounted Telephone
Thermostat + 60"
To9gle Switch + 42"
Room Number
Door Number
Relite Number
Finish Number
R:
Existing Wall
serest Tenant Demising Wa 11 . F�1.L1..
i Tenant Wall . G
Typical Spacing for Wall Outlets
Existing to Remain
Q-;
Detail
ngwirarsi7
I/
TENANT TANDY CORPORATION 11
950 Andover Park East
Tukwila, Washington
OWNER McCANN CONSTRUCTION Co.
PROJECT DATA
F- ` ilt-i o No4 t lr• Q,NG NA-L.
n
Ceiling Diffuser
Drawing tJntr
MR_ .F, , `. f' ; t. ' " , lAfJN(x'- -. h
14
Ceiling Return
Exhaust Register
Sprinkler
Grid Lines
ARCHITECT
CONTRACTOR
ELECTRICAL
MECHANICAL
LPN /Royce A. Berg Architects
McCANN CONSTRUCTION
COMPANY
Bid Design
RECEIVED
Bid Design CITY OF TLJKWil..A
MAY - 8 1981
BUILDING DEWM°
SHEET NO' OF
SYMBOLS
DIRECTORY
DATE: r/4 M7
DRAWN t /KM
•
8, 9
cMlnui tinl�i,t Iinli►�� IIolo') Ain 11x111111 i, ,Ii11 111111111 111111111
111111ni 1111111111111t1ii Inl11111 In 11111 11r1111ii 1
r X
(0-
0
0
EX I-1G LE-Ac-E- D
AC.
ANY WELL) CEILING W.E,11 LIGur F. TUBE TSTBtiarzb1
lu M LLT LATERAL BRArrnt& RizatixA imEW-rs FiR SEr m t 201.1E' 3.
TANDY CORPS 11
. -' w.l... VI.
0
0
0
7L.1►911.w 'ea.. `1.'_ Ilk'e
1
+e'44.4eL
JoIi.JT.
L-- I~.101=2,-F,70 - 1-1T5 P.. 1.Gt4 )
;)(I 6711 Mei L
00Th : / — wALl.4
\4 MtI L 15 SpAGE
rvig 5 IHL.LI;P ''IrMGZe.
DTI nil H r
0
0
L
FIELto vEPiF•r rove.rr
Ie &MovE
eveVi-le,60 t
vimvs .
m
.--+ ii i
F T
t -IXac. nFof.17 7 GLGI,
N /2'x4'G 1-61, D L4
4 LI6.0.4
;i ■
�NI t. - -2
1:xI4 - CT )
ri
1 J
ll
41
�!-.
Ha F.a,P e-e3vpr4c.T '
No NVA.-
Na 5uw..44 CA-41. H 1r4 Ur.1H1"
I >18
1#T vi1..1yL w/
"Ieu rz�a�
x15•r.' ::ek.:)2
�xl
4'.--01114ipm kiop,E P 161'4
4 WIDE a. vE
ItJ'/L'1-T t-4 v N I MOtb.
141/4.01-1- 112
�xI1�I01;x, C,oul\1'•
1,0--1,=-4-113-001-4
FFt ` I: Af,
Exim: wN L . C 1-11c. )
glITANA FLOoR1N G.
TO ComPc i c. 711 stic .
Sfo(6), iq$6UBC.,
5xKiT' aF'' -*..
ID
kzeMa./e
W611 , Apr) Hew/
viAU,, 1', Mew
0
0
0
0
0
❑
FLOOR PLAN
JOB NO:87024 SHEET NO OF
DATE / 6 1
DRAWN : 44
11 !;I!!li l
5
c"'linin111111I 1111it11 111111111
M!II1r 111 111n n1n11i11 It 11 n111 i
111111111 1�1IIII 1 1111111 111111111 1