Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 4849 - Bon Marche Distribution Center - Reroof
r. CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done Reroof BUILDING PERMIT PERMIT # 3q9 Control # 87 -308 Site Address 17000 W.Valley Hwy Building Use Property Owner Address Contractor Address Retail Allied Stores Carp P.O. Rnx 1251Q Tahnma Rnnfing Cn. 2615 South 112th Tacoma. WA Suite # Tenant BON DISTRIBUTION CENTER Assessors Account # N/A Phone # 575 -2194 Seattle_ FOR BUILDING PERMIT ONLY Zip 98111 Phone # 588 -9401 Zip 98444 S Ft. Sq. • Office Storagei Warehouse Retail Other Occ. Load 1st F1. 2nd F1. 3rd F1. Total _ Fire Protection: C1 Sprinklers E] Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL 100,000 Receipt # S.-7s 7 $ 640.00 Receipt # $ Receipt # $ Receipt #c‘-'; 1 $ a,50 Receipt # $ Receipt # $ 643.50 FOR SIGN PERMIT ONLY [[ Permanent [] Temporary [[ Single Face [[ Double Face [] Wall Mounted [] Free Standing [I Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Special Conditions Total square footage of sign THIS PERMIT BECOMES NULL ANU VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANUUNEU FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE C 1 D WITH HETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DUES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE 08 fANCEL HE PROVISI0 OF AN HER STATE OR LOCAL LAW REGULATING CONSTRUC 1ON OR E PERFORMANCE OF CONSTRUCTION. Signed�f_�!ee ''�!" ` / Date �7 r 1 hereby affirm that 1 am. is nsed der dis Contractor (signature)// 41 LENSED CONTRACTORS DECLARATION ns of the tsiness and Professions Code, and my 1icAnse�i$ in�fuyi� force Date ! (/f'i/ and effect. NER- BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) 1, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Date Owner (signature) . $� CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done Reroof Site Address 17000 W.Valley Hwv Building Use Retail Property Owner Allied Storas Corp Address P.O. Brix 12510 Contractor Tahnma Roofing Co. Address 261; South it2th . Tacoma. WA BUILDING PERMIT PERMIT # L% WC? Control # 87 -308 Suite # Tenant BON DISTR1t3UIIUN Ll:N CI< Assessors Account # NIA Seattle FOR BUILDING PERMIT ONLY Aniaraved fur I c cuanre by_ /., i ' Phone # 575 -2194 Zip 98 11 Phone f /1Zip 98444 v S q • Ft. Office Storage/ e Ware hous Retail Other Occ. Load 1st F1. 2nd Fl. 3rd F1. Total Fire Protection: [[ Sprinklers (] Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ sq. ft. @ sq. ft. @ sq. ft. @ 1st F1. $ 2nd F1. $ other $ other $ Total Valuation of Construction $ Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL 100,000 Receipt # 7) 7 $ 640.0) Receipt # $ Receipt # $ Receipt #V/--) 1 $ 3.5) Receipt # $ Receipt # $ 643.5 FOR SIGN PERMIT ONLY [( Permanent D Temporary 0 Single Face [( Double Face Wall Mounted [[ Free Standing Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions IHIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR ,WORK IS SUSPENDED OR ABANDONED FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK 1S COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH 4HETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE 9R ,,p)NCEL ;HE PROVISIONS' OF • My/OTHER STATE OR LOCAL LAW REGULATING CONSTRUCyIjO OR.j�7'}! PERFORMANCE OF CONSTRUCTION. �� fi r�~ /` /. %j^( / V �lI ICJ Signed /` //./ !'. 12- /4.-- >:; ---6 (/ Date ,r" dfENSED CONTRACTORS DECLARATION tins of the 9Gsiness and Professions Code, and my lic5e,is /in 1•Tjlorce and effect. Date / ONER- BUILDER DECLARATION or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or I hereby affirm that I am licensed u ,pder Contractor (signature) X,.'((fi lA7%• ( ) ( ) 1, as owner offered for I, as owner Owner (signature) of the property, sale. of the property, am exclusively contracting with licensed contractor's to construct the project. Date S' YRX'a4ak&7f.:hv�+:•h. Sy^1.Yhl..+ka:�t CITY OF TUKWILA Building Division Tukwila,�tWashington u198188 (206) 433 -1849 Type of Inspection /L'// /d/ (kekor) Site Address /24700 So ere-n INSPEC '4N RECORD PERMIT # .17/S2V Date /x /02 3 /7R Date Wanted /a2/3/�k Project Bon ,Di'sel--/iidt`IC -/ a.m. p.m. Requestor Phone # Special Instructions Inspection Results /Comments: /ave J- eee/veI d /et't'ek- 7 bra .e00 s dlit ��b -L ‘'r c 4ty 1pcc) kale, (kZt -- epz -zdea ) OT Date �23 1f f" TAHOM ROOFING Co., Inc. 1(x16 -25t11 Avenue South • 1'.( ). Box 44220 • "I<tuc>iitit, Wit,,hh ( I(>11 9444 -0220 (206) 5M8 -4401 City of Tukwila Building Department 6200 SouthCenter Blvd. Tukwila, WA 98188 Attn: Norm Bray Re: The Bon Distribution Center Reroof I AX (206) 582 -1332 DEC 221988! December 20, 1988. Gentlemen; This letter shall serve to certify that the above mentioned building was reroofed with a Class "A" roof system as manufactured by Owens- Corning. The system designation is 43 -IS consisting of the following: •) Two layers of 1 -7/8 inch thick Fiberglas rigid roof insulation, mechanically attached. b.) Four plies Perma Ply R fiberglas installed in solid moppings of hot asphalt. c.) The roof was coated with aluminum coating as manufactured. by Gilsonite Inc. I trust this is the information you need. JP:pm Encl. Sincerely, TAHOMA ROOFING CO. Jerry Pirak Vice - President CONT. LIC#TAHOMRC181 KT ' DEL (4,, MI Specification Index Gravel Specifications PERMA PLY•R 43-IG 33-TG 33-IG 23•TG 4P-IG 3P-IG 43•FG 33.FG 4P•FG 3P.FG 43•NG 33•NG 4P•NG 3P-NG 43•(G 33•(G 4P•)(6 3P-XG Slope Maximum 3" Deck Type NC;C.PL NC;C,PL NC:C;PL NC;C;PL NC;C;PL Vs" NC,C,PL 3" NC;C,PL 3" NC,C;PL NC;C;PL Vs" NC;C,PL 3" NC;C;PL 3" NC;C,PL NC;C;PL Vs" NC,C;PL 3" NC.C.PL 3" NC;C,PL NC;C,PL NC,C,PL Insulation, Min, Thickness 74" FG, P, W(NC Deck pnly) 1/4" FG 3/4" FG, P WINC Deck Only) 1/4" FG 3/4" FG, P WINC Deck Only) 34" FG, P WINC Deck Only) 1.3" 0 1 3" 0 1.3" 0 13" 0 N/A N/A N/A N/A N/A N/A N/A N/A Max. Thickness Unlimited Unlimited Unlimited Unlimited Unlimited Unlimited 4" 4" 4" 4" N/A N/A N/A N/A N/A N/A N/A N/A Mineral Cap 434C NC;C,PL 3/4" FG; 1" P (Max. 1" Slope) Unlimited Va " NC;C;PL 3/4" FG, P, W 4" 33-TC NC;C;PL 1/4" FG Unlimited NC;C,PL V." FG 4" 334C NC;C;PL 1/4" FG; 1" P (Max. 1" Slope) Unlimited NC,C;PL f4" FG, P. W 4" 23-TC NC;C;PL 3/4" FG Unlimited 43-FC NC 1 3" 0 4" NC;C;PL 1 3" 0 4" 33.FC NC 1.3" 0 4" Vs" NC;C;PL 1.3" 0 4" 43.NC NC N/A N/A 1/2" C;PL N/A N/A 33•NC NC N/A N/A C;PL N/A N/A 43•XC NC N/A N/A C;PL N/A N/A 334(C NC N/A N/A C;PL N/A N/A Emulsion 43'IS NC 1/4" FG, P 1" NC M" FG. P, W 33•S NC 1/4" FG, P 1" NC 4" FG, P, W 33-TS NC 1/4" FG 43•FS NC 1.3" 0 43•NS NC N/A N/A 43-XS NC N/A N/A Aluminum and '' 0..4..1111116'ii•';' NC V." FG, F' 1" Acrylic • ½" NC 3/4" FG. P, W ' '331IS NC Vii" FG, P 1" V," NC 3/4" FG, P, W 33•TS NC MI" FO 4" 43.FS '1/4" NC 1.3" 0 4" Unsurlaced B Mineral Cap Acrylic Aluminum C Minato' Cap 434S 33•IS 43•NS 43-XS 3" NC 1/4" FG; 1/4" P 1" NC 1/4" FG; 1/4" P 1" NC N/A N/A NC N/A N/A 434C NC;C 1/4" FG Unlimited 2" PL 1/4" FG Unlimited 334C 3" NC,C 3/4" FG Unlimited 2" PL 3/4" FG Unlimited 23-TC NC;C V." FG Unlimited 2" PL 3/4" FO Unlimiled 43.FC NC 1.3" 0 4" 33.FC NC • 1.3" 0 33•NC NC;C N/A N/A 11/4" PL N/A N/A 33- XC NC;C N/A N/A 43•NS NC,C,PL N/A N/A 43•IS NC Vs" FG; IV P 33-IS NC fie FG; 3/4" P 43.NS VI" NC,C;PL N/A 1" 1" N/A 434C 12" NC.C.PL V." FG Unlimited 334C 12" NC;C,PL 1/4" FG Unlimited 23-TC 12" NC;C;PL 1/4" FG Unlimited 43-FC 12" NC;C;PL 1.3" 0 4" 33-FC 12" NC;C;PL 1.3" 0 4" 43-NC 12" NC;C;PL. N/A N/A 33-NC 12" NC;C;PL N/A N/A 43•(C 12" NC;C;PL N/A N/A 33.XC 12" NC;C;PL N/A N/A Emulsion 434S 3" NC;C;PL 14" fG Unlimited 334S 3" NC;C;PL 3/4" FG Unlimited 33•TS 3" NC;C;PL. V." FG Unlimited 43-NS 3" . NC;C;PL N/A N/A 43-XS 3" NC,C;PL N/A N/A 26 Insulated /Smoth /Unsurfacedl 43 -IS . 41 -IS PERMA PLY -R PERMA PLY -IV 43 -IS All Areas 41 -IS All Areas Application of Insulation Apply roof insulation in accordance with specification requirements. Insulation joints should be staggered in one direction. For multiple -layer applications, joints of each layer should be offset a minimum of 6 inches from all joints of the preceding layer. Application of Plies Embed four plies of PERMA PLY in shingle fashion (starter sheets required), lapping 271/2 inches into uniform moppings of hot asphalt, using a nominal 23-45 lb/100 ft2 per ply. Plies may be left exposed up to six months without surfacing. Application of Surface • Asphalt - coat entire surface using a uniform mopping of hot asphalt at a minimum of 15 lb and a maximum of 20 Ib/ 100 ft2. • Emulsion - coat entire surface using not less than 3 gal /100 ft2. • Aluminum Coating - coat entire surface using 1.5 -2 gal /100 ft2 applied with brush or squeegee. Unsurfaced' Due to the inorganic characteristics of PERMA PLY -R this specification requires no surfacing for the finished plies. ' Unsurfaced specifications require PERMA PLY -R and drainage. A minimum of 1/4 inch per foot slope is recommended and a 1 /8 inch per foot slope is required. Interply/ Surfacing/ Slope Nominal Installed Ib/ 100 ft2 (Below weights exclude roof insulation and are provided for system design consideration) 43 -IS 41 -IS 152 152 Roof Insulation Felts 11/2" ..{ Coating } II27,,36 ;, Application of Insulation Apply roof insulation in accordance with specification requirements. Insulation joints should be staggered in one direction. For multiple -layer applications, joints of each layer should be offset a minimum of 6 inches from all joints of the preceding layer. Application of Plies Embed four plies of PERMA PLY in shingle fashion (starter sheets required), lapping 271/2 inches into uniform moppings of hot asphalt, using a nominal 23-45 lb/100 ft2 per ply. Plies may be left exposed up to six months without surfacing. Application of Surface • Asphalt - coat entire surface using a uniform mopping of hot asphalt at a minimum of 15 lb and a maximum of 20 Ib/ 100 ft2. • Emulsion - coat entire surface using not less than 3 gal /100 ft2. • Aluminum Coating - coat entire surface using 1.5 -2 gal /100 ft2 applied with brush or squeegee. Unsurfaced' Due to the inorganic characteristics of PERMA PLY -R this specification requires no surfacing for the finished plies. ' Unsurfaced specifications require PERMA PLY -R and drainage. A minimum of 1/4 inch per foot slope is recommended and a 1 /8 inch per foot slope is required. Interply/ Surfacing/ Slope Nominal Installed Ib/ 100 ft2 (Below weights exclude roof insulation and are provided for system design consideration) 43 -IS 41 -IS 152 152 Application of Insulation Apply roof insulation in accordance with specification requirements. Insulation joints should be staggered in one direction. For multiple -layer applications, joints of each layer should be offset a minimum of 6 inches from all joints of the preceding layer. Application of Plies Embed four plies of PERMA PLY in shingle fashion (starter sheets required), lapping 271/2 inches into uniform moppings of hot asphalt, using a nominal 23-45 lb/100 ft2 per ply. Plies may be left exposed up to six months without surfacing. Application of Surface • Asphalt - coat entire surface using a uniform mopping of hot asphalt at a minimum of 15 lb and a maximum of 20 Ib/ 100 ft2. • Emulsion - coat entire surface using not less than 3 gal /100 ft2. • Aluminum Coating - coat entire surface using 1.5 -2 gal /100 ft2 applied with brush or squeegee. Unsurfaced' Due to the inorganic characteristics of PERMA PLY -R this specification requires no surfacing for the finished plies. ' Unsurfaced specifications require PERMA PLY -R and drainage. A minimum of 1/4 inch per foot slope is recommended and a 1 /8 inch per foot slope is required. Interply/ Surfacing/ Slope Bitumen Type Materials per 100 ft2 Interply Felts 4 plies Bitumen 0 -1/2" II, III 100 Ibs 1/2 -3" III 100 Ibs Above 3" IV 80 Ibs Surfacing Asphalt or 0 -1/2" II, III 15 -20 Ibs 1/2 -3" III 15 -20 Ibs Above 3" IV 15 -20 Ibs Emulsion or 6" Fibrated 3 gal Aluminum or 6" Fibrated 1.5 -2 gal Unsurfaced' 6" General Note All general instructions contained in the General Requirements section of Owens- Corning Built -Up Rooting Products Reference and Application Guide, Pub. No. 5 -RW -13121 shall be considered part of this specification. Drainage Roof decks must be graded to drain all water freely. Drains shall be sufficient in number and size to assure rapid elimination of water from the roof surface. Nailing Treated wood nailers are required on inclines exceeding 2 inches per foot to help secure insulation and roof membranes to non - nailable docks or to decks with insulation. Nailers should be the same thickness as the insulation and should be installed perpendicular to the slope on approximate 8 fool face -to -face for slopes up to 3 inches per foot and approximate 4 foot face -to -face for slopes greater than 3 inches per foot. Felts are to run parallel to the incline and must be secured at each nailer, maximum 18" in from the back edge of the felt, Each nail must be covered by succeeding plies. High temperature areas may require nailing on lower slopes. m •• a• u• Pry Ede. To Ply Edp• -- - PERMA PLY PIW Boa of Ply To Nil Fleshings See Flashing Section of Owens- Corning Built -Up Roofing Products Reference and Application Guide, Pub. No. 5- RW- 13121. 32 -. CITY OF TUKWILA '. Building Division BL ..DING PERMIT APPLIL. 4TION 6100 Southcenter 8outevard . 4 Tukwila, Washington 98188 Control # g7% 6 -- - Project Name /Tenant - -,,� (ja,U D /57 -1(77 o/v c7Jz Valuation of Constructio !O U/ d U-0 7 Assessors Account# Property Owner 111 GL//f� srdre Coop. Phone -S.7$ - z/q y Address • > o. _ / • 5 'L/ .: 91; p Zip ?W(. /( Applicant % 1-eiX14- Roar- ue, Co ., Z",(./C. • Phone .. .1 -67 4f vl Address 2 / - 50. 1/2 74CDmf4/ t`'4 Zip 473Y4-/y Architect /Engineer C e,s 1 AJ . Phone Address .4W/( //(ve: , l /,°-) . (:* ..imG / /cm Zip , Contractor --r'/-1 oJH0/ 4 'Pc_.,c C,j 7 i cense #7/ /o '/l C /(o ( Kr- Phone •S&3 -(5/1./0/ Address 24/5-- SD //2...---`-' rr74(707/11 74- 6,L3f1 Zip 9gC1/Cr t( Class of Work: • New ❑ Addition [] Tenant Improvement D Remodel (residential) Kf Reroof [] Demolition Interior Demolition El Other Describe work to be done Zf / /lct- /Sff ,kiS? /A(C.. RocF %O Gu-ou) ,O, C1c. 9I. ,ar c #cri 407/1 C ,455 ''19 '"oar- Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building /co aav 5f. Square footage of tenant space /OU ooed 5 F. Building Use Gt -6eZ Hou,CE-- Will there be a change of use? [] Yes , , N Will there be storage or use of flammable, combustible or hazardous materials on the premise or area of construction? VI Yes E] No If yes, explain // ©7- f95PH -- -r GJ.L4. /jE., 645, 3 Az 7 -1.7 i C a u ,f 3 c c a , c - C o /U57-iz /t c_ 7 c 4J I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK. Applicant /Authorized Agent (signature) ^ �i -� / /Pa,/ Date g- /D -6'7 (print name) 0,//9/e0c. R. s2/77 1. Lid Contact Person (please print) /2 //4-4/G g. Otel.364,1t.c,D Phone 6-65 &'414'6/ .