Loading...
HomeMy WebLinkAboutPermit 5083 - Norco - Storage RacksCITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -- /54.9 t Work to be done Site Address Building Use Property Owner Address Contractor Address T.I. (Racks) BUILDING PERMIT PERMIT # S g3 Control # A7 -430 (513) 18201 Olympic Avenue S. Suite # Tenant WHOLESALE DISTRIBUTION Assessors Account # CORPORATE PROPERTY INVESTORS Phone # 575 -3025 18200 CASCADE AVENUE S. SUITE 124 TUKWILA Zip 98188 MATERIAL FLOW MATERS *68PK Phone # 575 -8682 1073 ANDOVER PK E. SEATT r e Zip 98188 Approved for Issuance by: /1 ! , / NORCO PRODUCTS U.S.A. INC. FOR BUILDING PERMIT ONLY S q • Ft. Office Storaehouge/ se War Retail Other Occ. Load 1st FT. 2nd Fi. 3rd F1. Total Fire Protection: J Sprinklers [] Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ sq. ft. @ sq. ft. @ sq. ft. @ 1st F1. $ 2nd F1. $ other $ other $ Total Valuation of Construction $ 8,000 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt #0403 $ 200 On Receipt # $ Receipt # $ Receipt # $ 3 Fin Receipt # $ Receipt # $ $ 2nn 5n FUR SIGN PERMIT ONLY [( Permanent E] Temporary [] Single Face [] Double Face [] Wall Mounted [J Free Standing ❑ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions 1HIS PERMIT BEGUMES NULL ANU VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANUUNLU FUR A PLRIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY TIIAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PQOVISJONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTIO OR THE PERFORMANCE OF CONSTRUCTION. Signed �rnl1 Date_ LICENSED CONTRACTORS DECLARATION I hereby affirm that I am licensed under provisions of the Business and Professions Code, and my license is in full force and effect. Contractor (signature) Date OWNER- BUILDER DECLARATION ( 1 I, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered kr gale, 96 1, as ogrof the am exclusively contracting with licensed contractor's to construct the project. Owner (signature) i• t ZZ(Q� Date rop rty, rr� -A-K i- ..jq�i�v ITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1845 Work to be done Site Address Building Use Property Owner Address Contractor Address T.I. (Racks) BUILDING PERMIT PERMIT # 5 C Sc3 Control # R7 -430 (5130 18201 Olympic Avenue S. Suite # Tenant NORCO.PRODUCTS U.S.A. INC. WHOLESALELDISTRIBUTION Assessors Account # CORPORATE PROPERTY INVESTORS Phone # 575 -3025 18200 CASCADE AVENUE S. SUITE 124 TUKWILA Zip 98188 MATERIALFEOWW MATERS *68PK Phone # 575 -8682 1073 ANDOVER PK E. SEATTI4 s Zip 98188 Approved for issuance �: ,64w FOR BUILDING PERMIT ONLY S q • Warehouse e Retail Other Occ. Load 1st F1. 2nd Fl. 3rd Fl. jota1 Fire Protection: ❑ Sprinklers 0 Detectors Zolli ng_ - Type of - Construct`i on. __ Special Conditions Fees sq. ft. @ sq. ft. @ sq. ft. @ sq. ft. @ 1st F1. $ 2nd Fl. $ other $ other $ Total Valuation of Construction $ 8,000 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other Receipt # / »f( $ alp Receipt # $ 3n0, Receipt # $ Receipt # $ 3.ri0 Receipt # $ Receipt # $ TOTAL ^$ �03.5n FOR SIGN PERMIT ONLY ❑ Permanent ❑ Temporary ❑ Single Face ❑ Double Face ❑\Wall Mounted ❑ Free Standing ❑ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions 1HIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK 1S SUSPENDED OR ABANDONED FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DUES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE UR_ CANEL THE P5OV1S ONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. Signed J'' 'e.'1--} —�' .i, /) •L?._ -- -' Date I / //gJ, -7 LICENSED CONTRACTORS DECLARATION I hereby affirm that 1 am licensed under provisions of the Business and Professions Code, and my license is in full force and effect. Contractor (signature) Date OWNER- BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Xf) I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. 1 1Y./ Os-? - -- - — - Owner (signature) Date CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433-1849 Type of Inspection Site Address /02o/ Requestor 7,7-2CYL,57 Special Instructions INSPECTION RECORD PERMIT # _Ccicr-7 Date Date Wanted Project A6Aro Phone # .251- 7)3 72 Inspection Results/Com ents: Inspector Date PSI/PITTSBURGH TESTING LABORATORY 7400.3rd Ave. So. Seattle, Wash. 98108 7 (206) 762.4664 Project: Lee.) '� �� Order No: Address Permit No �% i4- ':x.14 rL' //-75- ( - Inspector:`,� -� Date: d Report No Inspection Report of .. � ! Lam•. _.� l.i. 1,Q! 1 Lr1 rf .L C,.�'/.c I �,.��+ d r, (.7 ,/.G G�c.� .f t .,� t!'2^ 41.41 . at-f u,. i.li? 7c /41-1,(J �✓/ /r , r Vii - Gde- , ll-- i/' 2 ‘ , ' e/66‘ le afi-PA adei: ( /241 , CITY OF TUKVILA Central Permit System G,ntrol No - y %' Permit No. FINAL APPROVAL FORM J TO: ❑ Building ❑ Planning ❑ Public Works IS Fire Dept. ❑ Police ❑ Parks /Recreation Project Name C /7/Ce:/ c T S tJ. S. Al _ / //C Address / z c7/ ("7, ,vyQ) r Type of Permit(s) T /- /its< S This project is nearing completion. Please investigate your area of responsibility and indicate below either your final approval or necessary corrections. If no response is received within one week, it will be assumed that the project is of no concern to your department and a certificate of occupancy may be issued. This project is NOT approved by this department; the following corrections are necessary: () () () () () () () ( ). () () () () Authorized Signature Date This project is approved by this department: �,. Authorized Signature _c7 Date CPS form 3 J City it of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Hubert H. Crawley, Fire Chief Gary L. VanDusen, Mayor ' November 18, 1987 Fire Department Review Control Number 87 -430 Re ::;.Norco products U.S.A., Inc. - 18201 Olympic Avenue South, Tukwila, Wa. Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. i't. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 76' or less. (NFPA 10, 3 -1.1 and UFC 10.301b) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.6), and shall be installed so that the top of the extinguisher is not more than 5 ft. above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) 2. Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 12.114. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12 :104b). City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Hubert H. Crawley, Fire Chief Page number 2 Gary L. VanDusen, Mayor EXIT signs, shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not Less than six inches high with a minimum letter width of 3/4 ". (UFC 12.114a & 12.114b) 3. Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4- 1.1.1) All modifications to sprinkler systems shall have the written approval of the Washington Surveying & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall continence without approved drawings. (City Ordinance #1141 & NFPA 13, 1 -9.1) 4. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.208) 5. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File nod C�" grazji:TaPrP.- CONSULTING ENGINEERS /CIVIL AND STRUCTURAL 17, October 21, 1987 Sekai Bicycles A Division of Norco Products LTD 626 South Alaska Street Seattle, WA 98108 Attn: Mr. Tony Moore RE: Seismic Analysis of Storage Racks for Tukwila Warehouse (R.E. Job No. 8710 -193) Dear Tony: Inspection of the Storage Rack sketches revealed two basic geometries and loadings. These situations are illustrated on pages 1 and 4 of the Seismic Analysis and the calculations were performed based on these geometries and loadings. Under these conditions, the Storage Racks were found to be stable with the addition.of expansion anchors and footplates as recommended on pages 3 and 6 of the calculations at each leg of every rack. This method of bolting will accept a resisting force deemed adequate per the 1985 UBC Standard for seismic loading with respect to overturning. If you have any questions, please contact one. Sincerely, Alan F. Poe, EIT ., �. AFP: tm Attachment' w MOUNCR f OV .16. 1987 cri— cif LA PLANNING is :PT. CiT OF 'I'LIMLA APPROVED' "NOV 181987. 1501 14rest Vsil•y Highway North /Suite 101 Post OUice Box 6i6'Auht.rn, WA 98071 22C/5.8g :.7776 mil • • ILD N(.i ©ft't51UN • RUPERT ENGINE 'mg, INC. 1501 W. Valley Highwdy Ste. 101 P.O, Box 836 AUBURN, WASHINGTON 98071 (206) 833.7776 JOB SHEET NO STG�t- A.�.e.. RAGAS CALCULATED BY AFP CHECKED BY SCALE OF DATE / DATE w'7Ccn1)� .15 wv_ .T ..3...t......... Y74.. ..,. c .........1..... t ! i 4 t. I 1 , , .w7 Ti' P-t c?c C� ..t -t ∎,.v Pa:p_ I I — . ....... 'F i 4 I ; CITYi�I . t ...W.l.Llt) AIPPL� V D f 4 .............. 1 j 1 fXOplCI t041Firefilnc: (+olun, Min OUII. BUILDING DIVISION RUPERT ENGINE( ;, INC. 1501 W. Valley Highway Ste. 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833-7776 JOB SHEET NO CALCULATED BY CHECKED BY SCALE OF I�4—P DATE DATE i I I l I.... M-1..- ti »CS t>OED _....... ; r? •"1. ...... -A.-4c= 4 C l IfR .'fir - Z1-1.._5". ' ?1;56 1 _ ilk I i I ?.. •aP Rr1 -XS� l.c� AC'Et� = C / lo, 4 $ 12.:3,6 71. C (5.t .54k (C.1<=,/ . 0o /4,4 i4\ . 14. l•. I ,. i... : ; ,. ...I. I `,So% ' I I I �...... CITY !OF ...0 EKVWI LA APPROVED NOV 1;81987 IBSNOIE'D 43I)ILDING DIVISION .... f... ... ; ............. :... ...... .. ... .... ......, ... ............. .: • A.C�Q\"Rc,b. L ! ys-SING N- E.N -r'l' �� i�n� .....t.....� \' t�. %�. .......�:A`��e-''_ ...:. \, 5... F:.�5 .._) . . 1 f i • 1 i i ' � s ` 1..' +111 i : Z, G S I t4t i I : i I : 1 ! ! I3 .. .................:.......1�ai3. : 1 X66 - i r Tom► ->>'�- Fon.C�E. Q.ECa9 �E.+la ■..iEL. , 1*OD C1001I (NrTi5)1nc. Won. Moss. 011)1. RUPERT ENGINE ''' 1, INC. '1501 W. Valley Highway �. Ste. 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833-7776 JOB ,•' -vc\3 SHEET NO 3 OF 8 CALCULATED BY XV? DATE kO ar, ' $'; CHECKED BY DATE SCALE SL 3or.ar.mb . @s� A ... C a m:. G . 4 1 - • esu. s 3 t. lac • 4g�b8.,'ik 1 • `4L 3 esi c I i 1 Y....O:F....TU KI I LA ............. • A..PPRQVFD i I NOV 197 : ............ N Ivlj 1 tU i I BU nl..D.l� /I.S.I.QN ................. I ! i l P OWC=204 i /1833 %Ia. Wm. Km 01411. RUPERT ENGINE( INC. 1501 W. Valley Highway k Ste. 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833-7776 • JOB 1■3c?(- - -Ar.-14 eft I. SHEET NO Or CALCULATED BY 46.X- V3 DATE CHECKED BY DATE SCALE I . I 1 , I • I ! MAkkl■••■■■■■ • 1—c..4z, • • 0.1E-441r : VUJOalti dz .kS vt.xpk_18k 4,k; •I• i I \ tAD,..7 -E,,,.!:\c\. ' , 7.1e)',16‘ : V; \ ; \ • .1.. .. 1 i.. ...,. I. 1.. I , I ; 1 . .! I ; 4. • 4 1 , I I i . 1 I I i I i l' •••I•• : . i I 1- '• ..! .. •;;;; i...; ..,,.. ', , , I ' , , . . . .f", "cor■,. ....1, _•::);,-. 1: ....1 i ; I ! . I . i ; • I if I i . 1 f I 1 ! f 4 - , T lcm, .ds lit' i • i , , I 1 i , 1 ' i I 1 I i I I i -ek 1 i i i • . I . ! i 1 i i \ 44e•\ . 2\, ! i i 4 I i ' ! • i 1 I 1 i ! • ! . 1 I . • - . ! ! ' . i ..1 .... .. . ..i. ,. ..,. .. : 1 1 . . 1 I I i i I 1 1 I ; i • 1 -A.+2!)-Vls..*1 i ! 1 1 1 1 Ar_ - Cos".. st,A.r.;„-•!4...5.i.. ..6,,---44ze..:1::, -. .. , . ....,.. , , , , 1 . F*--,4. . %. ■-Li.1-7 i. , • 1 ,..1.15coc,44 klic,,,44t" 1 I 1 . • : : i : . . . : I , . ; . : , ! : i . . 1 T ! 4.. ' I • I I . .... T. ..i ... 1. .... C TY,;OF if OVVILA : i 1 I. , APrRjOVIED ..1 i. -1 ' 0 .1'6 1987 . '41.. .. . , 4 1 I I 1 1 I! t 1 I 1 AS NOlEp 1 . 1 1 . 1 . 1 . 1 1 1 i 1 i i I 1 ILCIIN DiyISION11, , li H I 1 1 Bll i i 1 • MODULI MCI (NEM/ Int., Polon, 01471. RUPERT ENGINE ING, INC. 1501 W. Valley Highwl Ste. 101 P.O. Box A.. AUBURN, WASHINGTON 98071 (206) 833-7776 JOB SHEET NO OF CALCULATED BY ATP DATE iU / CHECKED BY DATE SCALE 1 ; j I L , f ToP � LM .ks' +` .Uzi;. -0) ks: ' - 4C,\- -V\**) z•Cc\.'_.. 63o3.z. • l i 1 1.... 1 1 1 1 i , PS.SIS I V\-C, 2,1 i 1 I. I I I I ' : 1 i j.. i I ? f i i I 1 ..i } 1 1 , i 1 i 1 I__ I i I 1 Y (J i- I i.i,• VV i I p • 3.....I..,........(-1... 5•.∎�.).k...5 -'?.w ....��1'k ..`�`i yr ... ...._........ -'pip , 1 i i1� , , • -I ... . 'I. . • ,,, :Noy •I 9 Apt �-R_ ra l� ¢. A. VF-C. I I 1 I I BUILDING. DIVES ON Y�, I I I 1 i i T. 1 I 1 I t i 1 r ! ii 1 1 I I 1 I 1 I 1 1 i 1 l 1 i 1 1 .1....... 1... .. ..... ..... j . I i 1 1 I 1 1 i ? f i I I + • , -- Ga1/4 1 cam s 1 I 1 1 I Rua za 1 /Arras / Ia.. wow. Wu 01411. RUPERT ENGINE( INC. •1501 W. Valley HighwaY1,.. Ste. 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833.7776 JOB SHEET NO OF CALCULATED BY A.VN, DATE L (LA 1 CHECKED BY DATE SCALE :c3r. • • • 1 ; i ; . . . ' . . . . . . . .. . . . ! ■ . . . , . . . . . . : .• . . . . i'. • -, • .. ! c;„,* 0 ,t:)• : cc..,,;... : •,, Gt."'S (..) • C—yle—r.--N4—• _- 6C-77 1 ' €7,7* i'±■4,..svu.i : *!,,.A.I.(ZIA* ?St: I /164-X4‘.% nc -1. 2.E L%:,?.P.A .)4/,1* • ! ! : I , • ; ■ i .3.,!:•±177774,f0,, \-k-f-b4: Vz• a=c; ) 1/4 # s 1, : • il . , : I • I u Vi • 1/4._:=126.c) ArS 44) 5'4 t • ir tt•k..rat !fsC i: • 1 ::: .), ,. I ag', C, L \ !" .'ll'' . ie iiii,,I,' ... . •.'ill. .. . .! ,.... • : : \-.t t I` cr44■."1/4 );1/4.4g1q1- gc •t C c■-% . N-: I . ; ' • : • : • Jr_ .„, ( 4,%•'‘ '::(._ lit) 6. • I . I I -'-Af--• •-i 3(16 61 Z. AI.E- 11 1 I : I I : i i : ■ , i 1 1 i , 1 1 I p ,IT01.1,iviCVE..tDA-11 1 .1 14 i 1 8111987 li T • ■ i 1 i 4 I 1 1 Bu Loikt\IIGIIIDLIDvIst9Im • I 1 ; 1 I i , .... 00000C12011 livenhl lac, Goo!. Mau 0171. •1 1 TruBole Wedge Anchors FEATURES Hole size = bolt size —Ideal when work being attached is drilled while in position, and drilling continues into the concrete, eliminating the need for templates arid' double handling. One piece wrap - around expansion sleeve— Provides true 360° hole contact for greater reliability. The large expansion sleeve area also reduces concrete unit stress. Works in bottomless hole —The bottom of the hole is not needed to set the anchor. In most applications, the anchor is set as the object is fastened in place. Supplied as a complete unit —Nuts and washers are packaged with each box of TruBolt anchors to simplify • installation and (educe inventories. INSTALLATION Hole is to be drilled the same diameter as anchor, to any depth equal to or greater than the required embedment, using carbide - tipped drill bits conforming to tip diameter tolerances of ANSI B94, 12 -77. CITY OF TUKWILA APPROVED NOV 181987 • li l'i\11 fai FF. raEl 1 a:5./ 1itG�gijr 7:7,2 •.s.. Zviw:�(.'�.r tt rur RN -r, Y7' J ayk t�•t +'3 • • ;,;!,ViC7•..::141 • + T •� Drill hole. Insert anchor in ' hole. . Expand anchor by tightening nut. LENGTH IDENTIFICATION • CODES Letter Stamp 00 Archer • ' Length of Anchor (Inches) Lehr Stamp Do Anchor Length of Anchor (Inches) • ' 'Froa . Up to Bit Net Including: Front . up to !et Not' lactating A 12 2 0 ? Bye e '` 00 • . 3 ... '3i • 0 P 9 91 10 • , E 3% 4 R 10 ' • 11 0 5 5 : T 12 13 J ' 6- 6/' W 14 16 11 7/ e ' Y 10• 19 2 t•���+f�� ,••i ,. ».A , i .V�ti Ir � ►•. ``�j t •v4r, •L'tt rL '4� i�` 2:f.:41 NraY ..s. - tr~:,+gt V.4.1 atr:"tt Vat- .i;•S:rr:�5 'R r:.. , } .. � /, .....:r.-....= �..,,, •-. ?' ,,..;:;._•r . : , .., • • >• ?�Y '+' {f�,� t i, 741 r i've i a ':i' V. + ;,,, ti .!....<. '., „ ...a c�'..'3 ?4.4:16: ib}'w�xii ;Lsi. ?r.,4, 1 a` 04 to.a.y ?2`,:� 4,.'� 17'•,i ..y,4 r 1 . . S:it w�]l Y �� �•s1l � Iy.�?13�� �.�'iM 11�w1 c%•ri.•i •i:��� T-...64' Y VI I 7 :.i. v ►+ .. ��} n tip. avert ,tit,« .4:4 ,. a, tz,...T 4 i ill El ilE rii El riii El El a o A d9Q. • •, �ap� •p a "j rtztvtied in' di. ti ° ; try. IA R' 54 ',fl�A•^ \'.•:t1.1. qa• 1,144: . n:'� • E yg 71.7 -�•!!P .aa -T1 1.RM .� 17 t �'.��1 t' • --� +: is `, • t. t. • • CITY OF T UKWILA APPROVED NOV 181987 i,.3 i` ;LIiEL) .!31111.0�NG ,PWUIS(GN —. SIZING INFORMATION & TECHNICAL DATA g/% • Anchor 5 Hole Diameter (in.) • Standard TraBelt Catalog Number Stainless Steel Trraott . Catalog Plumber "A" Overall Length (In.) "B" Thread Length (In.) "C" Max. , Thickness • of Material To Be Anchored (In.) "D" Embedment Depth For Test (ln.) Test Date Concrete Strength (psi) 3000 4000 5000 Tension bs. Shear • bs. Tenslon IDs. Shear lbs. Tension is. Shear IDs. 114134 TSS14134 114 34 X 1X• 1940 1060 1975 1180 2010 1290 )4 114214 TSS14214 234 • 1 1 114314 TSS14314 334 1 2 134 2480 1060 2550 1180 2620 1290 135214 TSS38214 234 13s X 1X• 3610 ,3890 . 3875 3890 4150 3890 138300 78S38300 3 134 134 135334 15838334 314 134 2 • 138500 — 5 134 334 4% 5810 3890 6130 3690 6460 3890 112234 TSS12234 234 134 X 234 • . 5120 7700 6360 7700 7610 7700 112400 TSS12400 4 1% . 134 X 112512 TSS12512 5% 1% 234 4 7710 7700 8890 7700 10070 7700 112700 — 7 1% 431 158312 755511312 3)4 1)4 5' 2 %• 8720 11200 9640 11200 10560 11200 155414 — 4)4 134 1 34 T58500 18688500 5 114 13; 158500 — 6 134 214 • • 158700 TSS58700 7 134 314 5 11810 11200 14930 11200 18040 11200 134434 TSS34434 434 2 X 3ib• 11700 16750 12990 16750 14280 16750 134514 — 534 2 1% 134614 15534614 634 2 2)4 134700 — 7 2 334 • T34812 T8834812 834 2 434 134100 — 10 2 8)4 9 16980 16750 21130 18050 25290 19570 175500 — 6 2 134 4• • 16190 19520 17340 19665 18500 19810 34 771500 — 8 2 3% 771100 — 10 2 534 7 17680 19520 27130 19665 36580 19810 . 110600 — 8 234 34 4X• 19000 26480 20350 29990 21700 33490 1 710900 — 9 234 3% 110120 — 12 234 834 8 24550 36550 32380 38620 40220 40680 131 111490 — 9 3% 234 '534 6)4 22960 33940 27550 39240 32140 44530 111412 — 12 3% 10 39300 48850 45510 53730 51720 57420 )4 T14 -114E — 2)4 X, 134 — — — — — — — •Minimum Embedment APPROVALS: 1. Underwriters Laboratories— Standard TruBolt diameters % "to 34"are U.L. listed. 2. Factory Mutual — Standard TruBolt diameters % "to'Y• "are Factory Mutual approved. 3. ICAO— Standard TruBolt anchors are ICBO approved under Report No. 2391. 4. Southern Building Code Congress (SBCC)- TruBolt anchors are approved, under the NOTES: 1. All values are average ultimate loads. Industry standard Is to,apply a minimum factor of safety of 4 :1 to obtain working loads. 2. Test data based on independent laboratory testing In hardrock concrete. Southern Standard Building Code, Section 103.6 'Alternate Materials and Alternate Methods of Construction" (Report, No..7304). • • :: (5. Federal Speciticatiolis ' ruBolt anchors meet the following specifications: Physical —FF -S -325, Group. 1!, Type 4, Class 1. Plating —ASTM B 633 -78, Type II, Class FeZn 5, SC -1 and QQ- Z -325C, Type I!, Class 3. •.'4- , : .T +n i7 afie. {� ; f,f. r, I::�''� I^ T: 1 :5; l : ~.. .•'" rAnt:; :...IS.i rr. T t7,.^• ,fd^�� Z:•`,� - e^}�'t'�,',�.•a siT,'� eM; y.:. r•.-; .rt •�" ! • �� �h''' 1 •yi ila••}}��,�y 7`, S ',`�•�}� i ! ./ ?• '•.n �L C'.ii i .. ,' ''•' •:: •1 •.w ±' •. i•: 'A�a, A�i1!• lt-1 C�::w /. .. w•iN: %�:k! YI'r " il%.h+. KAFr; R5 };+ IP +:t >•f4'�'.. 4. *:7+ •!':R' C.r i':! �'�ti`Y K.il. �..i: �::t`:.� K��iJ �"a!',1 : i•', .r t7:, C .lt:. ., • '."4i ik70 it -1 �,Y �7:�:' ti ,• �V IY,' r.•.4,••01.. 1 '•�. • F:'" •.a. r`�wi . •1r. .a �r �fi },.. �'�•(,'i, `t{.,.:d` a"'r'�' �*t1� ': 1�• ri Q '�. ,'f• :{l. �' !cY ;� ' k�:>,; i:•..'Lr !.�E�:! +'•1t:�.1., r�• ;• � i•• ?,. ��• • M i jr• i•y i ; "Y'• "4 1 ty• r•,{� ••�:1' r4� L�f. ••f: �'�•• r• t+ 'r , a•} H Z F..� 'l y N t V. ❑ C, r a f• «„ .r C. �, �, h. L ' i Y• IY' :. :�,, f'J.. •• LL:l: r 1r ��si t3i,+.. f •� �..L.. :,L i' �' f {'�u C•' 1- ;.i• ' Pit!. ►i:,.t WA; r:tE:...r: .a:•:o :, :�.td r ..0 �.�::� t?�i5. Y. ;.�. a`..t, IR't ;•r� •:� {� "::; •�. ir.�e:..t:.•,., • 3 NORCO PRODUCTS U.S.A. INC. .CITY OF TUKWILA APPROVED N -OV 1 8 1987 AS i O i ED 626 S. ALASKA Si SEATTLE, WA 98108 TEL.(206)682 -2730 IC -81-..1-1-69444G 14+44-S44441-- .! 'C' S 1e5 CoN pt. man-10m . CJILL At, 7uST IF NecEVsR,ey MA-ri Munn wW'4t -rr ('FR 50o LAS NVVVINI L.v► wEArte peNe. 6/44-i 000 L-Rs 1:t' i r CITY CY ' "'VILA AP.PRtVED 110V 181987 ivapit .R p( e-r Kia-c4IN 4 81.111.DIN J R NtoRi Dr CAILs, ?LP ASE Cip■.sTA-tT R�►�y FOSSE ,kr M( Lel/AL FLOC 2c6 -51S- $682 5, ).)4t. yy Ru,� Wacueub hI AR61{ou CITY OF TUKINILA APPROVED NOV 18 1987 AS -11011D -,4 CITY OF TUKWILA cy v` �` Tu00alouuthcenter Boulevard BU!{ ')ING PERMIT APPLIC '' TION Control # 094-4' (206) 433 -1845 w ; Site Address /12.0/ O /y,,1p,c Ave S. Suite# Floor# Project Name /Tenant A/ Cr( c Pf•oc.(c <cf3 a. 5./9. TIC Valuation of Construction Assessors Account# Property Owner (vrfc,r€ (. Prot-i7 SVUt ?S%rS Phone (206) 57S 362-5 Address j �CQ Cosce ce _ �ye. S . Sufic ley 7u/C_ ),1� Zip 7'/'Y' Applicant Norco f rccettc*. U5/1 Phone 6J)-�7 j 0 Address 62_6 S• /-3- /e/Sk■ Sf: St'q// (. LA-) q Zip r5 /Ca Architect /Engineer u44 Err- 4QC' -Yt Ile- Phone 1'33 —77 7c, Address /50( L,' e5 ( V'7 (ei /711.,A/ N . Zip qYC / Contractor Vita•/ e -(Q,L. 11°4) License# Phone 57'•-B4Y2.- Address /o73 Zhidj_,g Br P,� � `Q4-71ff Zip 9-/ g2e Class of Work: [] New 0 Addition EJ Tenant Improvement [] Remodel (residential)[] Reroof Demolition 0 Interior Demolition ,® Other Se f- -cfp of .570,-7,7,7 6y5• Describe work to be done Insfc( / /af/'h Of 5-6?(,/ reicKi'9 / i # En /ive -,'ice Iv (0 v,-,e e Se.15 -t✓ f c 3 co,- $, S •nr CO (/%ail Ce . Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building /38/c73/ Square footage of tenant space // 3.37 Building Use c:c.)ho(psa(f? (,( 01-r, /NA lion Will there be a change of use? Yes EI No If yes, describe change of use, including square footages of changed areas Will there be storage or use of flammable, combustible or hazardous materials on the premise or area of construction? Yes J24 No If yes, explain I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHOR ATION TO DO THIS WORK. Applicant /Authorized Agent (signature / GtiA^ -�`'..,, Date /0-5'17 (print Game) •r .i (, Xs —^ Contact Person (please print) 13reff Co Area c tyy MOO/ Phone 6$Z -273(71 OFFICE USE ONLY FEES: Building Permit Fee (000/322.100) $ 00,00 Receipt# (> L' o c2 Date Paid /( -/g -7 Plan Check Fee (000/345.830) Receipt# Date Paid Bldg Code Sur Charge (000/386.904) 3.50 Receipt# Date Paid Energy Sur Charge* (000/386.907) Receipt# Date Paid Other ( ) Receipt# Date Paid *New construction only TOTAL (OWES: $ 003,50 '..-) SQUARE FOOTAGE /BUILDING USE INFORMATION Square Footage of Entir Building: FLOOR USE /Occ Tvpe SQ.FT. 1 LOAD USE /Occ Tvpe SQ.FT. OCC LOAD. USE Occ T S.FT. OCC InAn TOT& SQ.FT. 7STA' OCC. 'TOTAU I I t - - --- .� _. • TRACKING DEPT. DATE IN DATE OUT COM BLDG �/\ ;,�c>�'` l\ Approved for Issuance Type o onst. I) 1It a.c i Rta.cam, ct 7 f - , -d aac�.e, i 1.--q --g • �,c.)I-u d'W To Mahan: ' Dale Approved: c�/1,Q [1 -5 FIRE ✓ Hui'? t/-r�-Y/ Approved (Initials)),IA- sz...•- Per letter dated //_177 Fire Protection: ..SprfTclers ❑ Detectors f13 PLNG Approves nitials • BAR MIL' 1 U " 1 1 1 Zoning Setbacks: N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: PWD Approved (Initials) Per letter /plans dated