Loading...
HomeMy WebLinkAboutPermit 5185 - Dania / Beebe Runyan - Built-Up RoofCITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 404; I i49 BUILDING PERMIT Work to be done Site Address Building Use Property Owner Address Contractor Address _(INSTALL NEW BUILT UP ROOF) 1251 ANDUVEF� PK . PERMIT # Control # 88 -059 Suite # Tenant DANIA CORP / BELBE- RUNYAN MULTI - TENANT FACILITY Assessors Account # 352304- 91U3 -O TRI -LAND CORP. Phone # 624 -4494 1411 FOURTH AVENUE BLDG SUITE 1120 STA'TLE, WA Zip 98101 CUSTOM ROOFING INC. #CUSTOR *291M9 Phone # 762 -01 /0 8001 - 5TH AVENUE SOUTH SEATTLE) WA dip 98108 FOR BUILDING PERMIT ONLY AnW'olted for Issuance b S Ft. Sq. • Office Storage/ warehouse Retail Other Occ. Load 1st F1. 2nd F1. 3rd Fl. Total _ _ Fire Protection: [J Sprinklers (J Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 133,000 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL. Receipt #.;;.:270 $ Receipt # $ Receipt # $ Receipt #:.. 76 $ Receipt # $ Receipt # $ 755.00 3.50 $ 758.50 FUR SIGN PERMIT ONLY 0 Permanent [] Temporary 0 Single Face [] Double Face [] Wall Mounted [] Free Standing [] Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions IRIS PERMIT BECUMES NULL ANU V01O IF WORK OR CONSTRUCTION AUTHORIZED I5 NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK 15 SUSPENDED OR ABANDONED FUR A PERIOD OF 180 GAYS AT ANY TIME AFTER WORK 15 COMMENCED. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SANE TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS ANU ORDINANCES GOVERNING THIS TYPE OF WORK WJLL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE ➢B0V1S1ONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR . THE PERFORMANCE OF CONSTRUCTION. Date \"5- /cr'c5W Signed � ( - c,-L,_ LICENSED CONTRACTORS DECLARATION 1 hereby affirm that 1 am licensed under provisions of the Business and Professions Code, and niy license is in full force and effect. Contractor (signature) A:I / z•� e.-c O 7 Date .3 / y ' —(x �/ OWNER- BUILDER DECLARATION ( ) I, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) 1, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature) Date CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 - /RI BUILDING PERMIT PERMIT # Control # 88 -05.9 Work to be done (INSTALL NEW BUILT UP ROOF) Site Address 1251 ANDUVLR 1'K W. Suite # Tenant DANIA CORP / BEEBE- RUNYAN Building Use MULTI - TENANT FACILITY Assessors Account # 3523U4- 91U3 -O Property Owner TRI -LAND CORP. Phone # 624 -4494 Address 1411 FOURTH AVENUE BLDG SUITE 1120 SEATTLE, WA Zip 981U1 Contractor CUSTOM ROOFING INC. #CUSTOR *291M9 Phone # 762 -0170 Address fl[l01 - 5TH AVENUE SOUTH SEATTLE4,WA ip 98108 ' i FOR BUILDING PERMIT ONLY l�ravprl for Tccuanrp hv: �//!,1!:'! S Ft. loffj q •Wce Storarehouse age/ Retail Other Occ. Load 1st F1. 2nd F1, 3rd FT Total Fire Protection: (] Sprinklers [] Detectors Zoning Type of Construction Special Conditions Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd Fl. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 133,000 _ Receipt # $ 755.00 Receipt # $ Receipt # $ Receipt # $ Receipt # $ Receipt # $ Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL 3.50 $ 758.50 FOR SIGN PERMIT ONLY ❑ Permanent C1 Temporary [] Single Face ❑ Double Face ❑ Wall Mounted [] Free Standing [] Other Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions Building face THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED I5 NOT COMMENCED WITHIN 180 GAYS, OR IF CONSTRUCTION OR WORK IS ',uSPEN0E0 OR ABANOONtU FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. HEREBY CERTIFY THAT l HAVE READ ANO EXAMINED THIS APPLICATION ANO KRUW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS ANO ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT OOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE UR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. Signed -- - -- / , Date LICENSED CONTRACTORS DECLARATION I hereby affirm that 1 am licensed under, provisions of the Business and Professions Code, and my license is in full force and effect. ;, ; :–, , _ G Contractor (signature)_ /1,_ : Date =-i d – OWNER- BUILDER DECLARATION ( ) I, as owner of the property, or my employees. with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( 1 1, as owner of the property, au exclusively contracting with licensed contractor's to construct the project. Owner (signature)_ —__ Oate_ 'ITT OF TUKWILA . Building Division 6200 Southcenter Boulevard Tukwila, Washinoton 98188 (206) 433 -1849 Type of Inspection Site Address /.2 57 Requestor Special Instructions INSPECT1N RECORD PERMIT # 57 8 6 - Date Date Wanted iour p•m• Project 3a/),,,A. wee -A? Phone # 7 6 O /' 70 Inspection Results /Comments: Inspector CUSIO�U aaoje#q, 9tc. 8001 5TH AVENUE SOUTH SEATTLE, WASH. 98108 PHONE 762-0170 TO: City of Tukwila 6200 Southcenter Blvd. Tukwila, Washington 98188 DATE: 5/27/88 •SUBJ:' ROOFING PROJECT: Multi Tenant Office / Warehouse Facility 1251 Andover Park West Tukwila WA GENTLEMEN: Custom Roofing has installed a new built`up`roofing membrane n compliance with the following specifications. - OWENS- CORNING SPECIFICATION # 31 -IC INSULATION 3/4" Fiberglass Per Owens- Corning specifications this roof has a Class Fire rating over q /inn Fiberglass Insulation Please see copy of specification attached. Sincerely, (;us om Ftoo e. E.L. Larson President FIBERGLAS InsulatecLap 33 -IC PERMA PLY -R Sheet,,'---- - ( 31 -IC N—PERMA PLY -IV Application of Insulation Apply roof insulation in accordance with specification requirements. Insulation joints should be staggered in one direction. For multiple -layer applications, joints of each layer should be offset a minimum of 6 inches from all joints of the preceding layer. Application of Plies Embed three plies of PERMA PLY in shingle fashion (starter sheets required), lapping 242/3 inches into uniform moppings of hot asphalt, using a nominal 23 -45 lb /100 ft2 per ply. Plies may be left exposed up to six months without surfacing. Application of Mineral Surface Embed 12 -ft. lengths of PERMA CAP (18 -ft. in Area III) with 2 inch (min. 1 ") side and end laps into a uniform solid mopping of hot steep asphalt, using a nominal 20 -30 lb/100 ft2. PERMA CAP end laps should be staggered minimum 3 ft. 33 -IC All Areas 31 -IC All Areas Interply/ Surfacing/ Slope Nominal Installed lb /100 ft2 (Below weights exclude roof insulation and are provided for system design consideration) 33 -IC 31 -IC 202 202 Application of Insulation Apply roof insulation in accordance with specification requirements. Insulation joints should be staggered in one direction. For multiple -layer applications, joints of each layer should be offset a minimum of 6 inches from all joints of the preceding layer. Application of Plies Embed three plies of PERMA PLY in shingle fashion (starter sheets required), lapping 242/3 inches into uniform moppings of hot asphalt, using a nominal 23 -45 lb /100 ft2 per ply. Plies may be left exposed up to six months without surfacing. Application of Mineral Surface Embed 12 -ft. lengths of PERMA CAP (18 -ft. in Area III) with 2 inch (min. 1 ") side and end laps into a uniform solid mopping of hot steep asphalt, using a nominal 20 -30 lb/100 ft2. PERMA CAP end laps should be staggered minimum 3 ft. 33 -IC All Areas 31 -IC All Areas Interply/ Surfacing/ Slope Bitumen Type Materials per 100 ft2 Interply Felts 3 plies Bitumen 0 -'/2" II, III 75 Ibs 1/2 -3" III 75 Ibs 3 -6" IV 60 Ibs Surfacing ' Asphalt 0 -3" III 25 Ibs 3 -6" IV 20 Ibs PERMA CAP 78 Ibs General Note All general instructions contained in the General Requirements section of Owens- Corning Built -Up Roofing Products Reference and Application Guide, Pub. No. 5 -RW -13121 shall be considered part of this specification. Drainage Roof decks must be graded to drain all water freely. Drains shall be sufficient In number and size to assure rapid elimination of water from the roof surface. Nailing Treated wood nailers are required on inclines exceeding 2 inches per foot to help secure insulation and roof membranes to non - nailable decks or to decks with insulation. Nailers should be the same thickness as the insulation and should be installed perpendicular to the slope on approximate 8 foot face -to -face for slopes up to 3 inches per foot and approximate 4 foot face -to -face for slopes greater than 3 inches per foot. Felts are to run parallel to the incline and must be secured at each nailer, a maximum 12" in from the back edge of the felt. Each nail must be covered by succeeding plies. High temperature areas may require nailing on lower slopes. 11.111 1 n yr 1 n.vr 1 11.1 3 1 1114' 1 n,vr 1 1111' Pry Edge To Ply Eder PUMA PlY PIMA BRY oll al Ply To N Fleshings See Flashing Section of Owens- Corning Built -Up Roofing Products Reference and Application Guide, Pub. No. 5- RW- 13121. 38 CITY OF TUKWILA 6200 So thcenternBoulevard BU DING PERMIT APPLIC'l "TION Tukwila, Washington 98188 (206) 433 -1845 Control # <45g -1097 Site Address 1251 Andover Park West Suite# Floor# Project Name /Tenant Dania Corporation / Beebe - Runyan Valuation of Construction $ 133,000.00 Assessors Account# J 2)QL1 -q/U .9-Q Property Owner Address Applicant Address Tri -Land Corporation Phone (206) 624 -4494 1411 Fourth Avenue Bldg., Suite 1120, Seattle, WA Zip 98101 Custom Roofing, Inc. Phone (206) 762 -0170 8001 - 5th Avenue South, Seattle, WA Zip 98108 Architect /Engineer N/A Phone Address Zip Contractor Custom Roofing, Inc. License# CUSTOR *291M9 Phone 762 -0170 Address 8001 - 5th Ave.nu South, Seattle, WA ZiP 98108 Class of Work: 0 New ❑ Addition ❑ Tenant Improvement ❑ Remodel (residential) ® Reroof ❑ Demolition ❑ Interior Demolition ❑ Other Describe work to be done Install new built up roof in accordance with Owens - Corning specification # 31-10. Will be adding 2 3/4 pounds per square foot. Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building100,500 Square footage of tenant space SAME Building Use Multi - Tenant Facility Will there be a change of use? 0 Yes ® No If yes, describe change of use, including square footages of changed areas Will there be storage or use of flammable, combustible or hazardous materials on the premise or area of construction? ® Yes Q No If yes, explain Hot asphalt. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK. Applicant /Authorized Agent (signature) (print name) Contact Person (please print) e ,,o-----0./.Date 3/1/88 E.L. Larson Ernie Larson Phone 762 -0170 OFFICE USE ONLY FEES: Building Permit Fee (000/322.100) $ '75-.5 [)C) Receipt# ;1,77 Plan Check Fee (000/345.830) Receipt# Bldg Code Sur Charge (000/386.904) ,i.50 Receipt# Energy Sur Charge* (000/386.907) Receipt# Other ( ) Receipt# V *New construction only TOTAL SQUARE FOOTAGE /BUILDING USE INFORMATION FLOOR USE /Occ Type SQ.FT. Date Paid ,3 Date Paid Date Paid Date Paid Date Paid / ,5U (OWES: $ 95$?,50 ) acc �QAD� USE /Occ Type TOTAL Square Footage of Entirq Building; OCC SQ.FT. J OCC ,LOAD USE /Occ TYpg SQ.FT. TOTAL SQ.FT. TOTAL OCC. TRACKING -DATE iN DEPT. BLDG FIRE DATE OUT r.• #7 PLNG COMMENTS , `App oved for Issuance — �9 Type of Const. To Mahan: Date Approved: Approved (Initials) Per letter dated Fire Protection: ❑ Sprinklers ❑ Detectors Approved (Initials) ❑BAR OLAND USE /SEPA CONDITIONS Zoning Setbacks: N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: PW0 Approved (Initials) Per letter /plans dated