Loading...
HomeMy WebLinkAboutPermit 5471 - Parkside Townhomes #A - GarageCITY OF TUKWILA (- Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 - igP9 BUILDING PERMIT Work to be done Site Address Building Use Property Owner Address Contractor Address New Garage bb3U -bb3Z S 1b3 St Residence (multi - family) Schneider Homes 6510 Southcenter Blvd., Tukwila, WA Schneider Homes #SCHNEI245P8 6510 Southcenter Blvd., Tukwila, WA PERMIT # 417/ Control # 88 -298 (513) Suite # Tenant Parkside Townhomes #A Assessors Account # 295490 -0250 Phone # 248 -2471 FOR BUILDING PERMIT ONLY Zip 98188 P66-iii-i# 248 -2471 Zip 98188 Da e: - 0 S Ft. Sq. • Office Storage/ Warehouse Retail Other Occ. Load 1st F1. 441 M -1 2nd Fl. 3rd F1. -Total Fire Protection: [] Sprinklers ❑ Detectors Zoning R-3 Type of Construction Special Conditions Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 6,478 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt #L3s 5' Receipt #5544 Receipt # Receipt #0,,-1 Receipt # Receipt # $ 81.00 $ 53.00 $ $ 18.50 $ $1.50 FOR SIGN PERMIT ONLY ❑ Permanent ❑ Temporary ❑ Single Face ❑ Double Face [] Wall Mounted [] Free Standing ❑ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions (HIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK I5 SUSPENDED OR ABAN00NEU FUR A PERIOD OF 180 OAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT l HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES VIOLATING THIS T WORK WILL B a! OHPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A P�MINOT PRESUME TO GIVE AUTHORITY 0 VIOLATE OR C CEL H PROYISI� ANY ER T STATE OR LOCAL LAM REGULATING CONST T !! PERFORMANCE OF CONSTRUCTION. Signed .� �I.L / . .., Date LICENSED CONTRACTORS DECLARATION I hereby affirm that I am 7t::)_ sed nder visa. s of the Business and Professions Code, and my 11c�� Mull force and effect. Date / Contractor (signature) "_ OWNER - BUILDER DECLARATION ( ) 1, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( ) I, as owner of the pr er y, am eecl ively contracting with licensed contractor's to constrpc? Owner (signature) Q'•1Viri0 Date (Il • CITY OF TUKWILA 4 Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 - /549 BUILDING PERMIT Work to be done Site Address Building Use Property Owner Address Contractor Address New Garage PERMIT # y V7/ Control # 88'298 (513) • 11_6 Residence (multi - family) Schneider Homes 6510 Southcenter Blvd., Tukwila, WA Schneider Homes #SCHNEI245P8 6510 Southcenter Blvd., Tukwila, WA Suite Tenant Parkside Townhomes #A Assessors Account # 295490 -0250 Phone # 248 -2471 FOR BUILDING PERMIT ONLY Approved for Zip 98188 Phone # 248 -2471 Zip 98188 iss ancP I2vL S Ft. Sq. • Office Storage/ warehouse Retail Other IOcc. Load 1st F1. 441 .M -1 -2nd F1. 3rd F1. Total Fire Protection: ❑ Sprinklers ❑ Detectors Zoning R -3 Type of Construction Special Conditions vI Date: 1/- /O - -, >J Fees sq. ft. @ sq. ft. @ sq. ft. @ sq. ft. @ 1st F1. $ 2nd Fl. $ other $ other $ $ 6,478 Receipt #L3Y Y'F $ 81.00 Receipt #5544 $ 53.00 Receipt # $ Receipt #t 3s $ 18.50 Receipt # $ Receipt # $ Total Valuation of Construction Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL $ 152,50 FOR SIGN PERMIT ONLY El Permanent [] Temporary [] Single Face Building face ❑ Double Face [] Wall Mounted Setbacks: Front Square Footage of each sign face Special Conditions ❑ Free Standing ❑ Other Side Side Rear Total square footage of sign THIS PERMII BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONEU FuR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT l HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS T . WORK WILL 8 OM/ IEO WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A �MI NOT PRESUME TU GIVE AUTHORITY N. VIOLATE OR C CEL H PROVISI• ANY k � R STATE OR LOCAL LAW REGULATING CONST TI PERFORMANCE OF CONSTRUCTION. Signed __^ L� / i _i ..1_i. . . Date LICENSED CONTRACTORS DECLARATION nder 11.visi. s of tht Business and Professions Code, and; y 1 /tens Is n full force and effect. J.... Date J (] 1 hereby affirm that I am ytL2gsed Contractor (signature) �, \L ( ) 1, as owner offered for ( ) I, as owner Owner (signature) OWNER- BUILDER DECLARATION of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is sale. of the pr er y, am 91c1 ively contracting with licensed contractor's to constrict th p`Ojes 0(19-$64460 Date 1111 00 not intended or kiMit.TJiIE . tke H4 ::n:9tB.:tS'f++n..,u.nw,+...... ...... ____ " CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1849 Type of Inspection Site Address c..30 ,? INSPE "!ON RECORD PERMIT # 7C Date /9'4446- 1.06/4440w Date Wanted -22 Project At"/✓,,4-.. a.m. p.m. Requestor Phone # Special Instructions " 3 - ? X/p l ;;.„, „,g /e. /'$ 41/4” ~0 f /9,i.-/ /144%. Inspection Results /Comments: 7i %,f/tl_ Inspector Date ,? ;Z� cS77 !`•"�i+'9S.`! :: SILO' 4tC�S�t ;n+cw..+�..r..�._�.._�_.__ ....._ _ CITY Of TUKWILA ;Building Division • 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1849 Type of Inspection Site Address Co y 3 0 Requestor Special Instructions rL.P S -� 4 (,I)Project 1�Q Phone # INSPECTION RECORD PERMIT # S y 7 Date 3 Date Wanted 2'/ j- _2471 a.m. Inspection Results /Comments: /_d_ 5 Nr e01 " •. Inspector Date 3 -.2 6ITY OF TUKWILA 'Building Division 6200 Southcenter Boulevard Tlikwila, Washington 98188 (206) 433-1849 INSPECT:ON RECORD PERMIT # 5 7 / Date II 0 S? Type of Inspection coot' WA Site Address)p G3 Requestor (Doak__ Special Instructions G.) %AL Date Wanted I 1/16/T2r an.p.m. Project ParkScIQ.. Phone # 2-41g Z- 4.7 / 1,11 Inspection_Results/Comments: /4-00G l/te-- s 4'1 aite./ /57e c-7 /DJ- ,o,_5" Inspector 7/d-7-14-1 Date ' CITY OFTUIWILA Central Permit System Permit No. r /71 Control No. �' � r z 97 FINAL APPROVAL FORM TO: ❑ Building ❑ Planning ❑ Public Works tgl Fire Dept. ❑ Police ❑ Parks/ Recreation J Project Name ,, y _� �, s ' ' ��.:- �. y . Address errs 34 - " 5 G: $ / -1: cii Type of Permit(s) This project is nearing completion. Please investigate your area of responsibility and indicate below either your final approval or necessary corrections. If no response is received within one week, it will be assumed that the project is of no concern to your department and a certificate of occupancy may be issued. This project is NOT approved by this department; the following corrections are necessary: () () () () () () () () () () () () Authorized Signature Date C This project is approved by this department: Authorized Signature 7-2 Date CPS Form 3 1 Y --C AteKS c D i;watA E T .TARA0•bE TO�a N c,E ��• 'ire 4.4 Lo530 5 153 T IS'�RM tT AppLIGA'j'IOIJ xic)' 3y- 6s38' 15404' x4' .-rce.c —E.-{- MSC 1531 (633 153 1153545 T 4 l ATTACHMENT S :/p4 • CITY Of TUKWILA APPROVED awd 1:.14 :1 it %6#4 e N= 20 `F'GP• L HCB ENGINEERING It CONSTRUCTION 3211 Callow Road Lake Stevens, Washington 98528 248 -2471 City of Tukwila Building Dept. 6200 Southcenter Blvd. Tukwila, Wa 98188 Subject: Parkside.Townhouses Garage PPermit# 5471 Address: 6350 -6532 so. 153 St. Dear Sir, On November 30, 1988, I wittnessed the foundation preparation . for the subject garage. Pier holes were provided at approximately 4' (foot). intervals or less around the perimiter of the foundation. The holes were then filled with concrete and poured monolithically with the foundation footings. The resulting pier and grade beam system as con -` structed will support the garage structure proposed without significant . differential settlement. HCB /eb toey0ittaftt R4 ca tz, 6; NN . ' 4 Y!' ,tt S 3 y. ` L 0 .. . A,,. As .b, -- q,'..;01' HCB ENGINEERING & CONSTRUCTION 3211 Callow Road Lake Stevens, Washington 98528 248-2471 City of Tukwila Building Dept. 6200 Southcenter Blvd. Tukwila, Wa 98188 Subject: Parkside Townhouses Garage •ermit# 5473 Address: 6531-6533 so. 153 St. Dear Sir, On November 30, 1988, I wittnessed the foundation preparation for the subject garage. Pier holes were provided at approximately 4' (foot), intervals or less around the perimiter of the foundation. The holes were then filled with concrete and poured monolithically with the foundation footings. The resulting pier and grade beam system as con- structed will support the garage structure proposed without significant differential settlement. Sincerely, H.C. Bloss HCB/eb HCB ENGINEERING & CONSTRUCTION 3211 Callow Road Lake Stevens, Washington 98528 248 -2471 City of Tukwila Building Dept. 6200 Southcenter Blvd. Tukwila, Wa 98188 Subject: Parkside Townhouses Garage ,Permit# 5474 Address:6535 -6537 So. 153 St. Dear Sir, On November 30, 1988, 1 wittnessed the foundation preparation for the subject garage. Pier holes were provided at approximately 4' (foot). intervals or less around the perimiter of the foundation. The holes. were then filled with concrete and poured monolithically with the foundation footings. The resulting pier and grade beam system as con- structed will support the garage structure proposed without significant differential settlement. Sincerely, H.C. Blass HCB /eb *0444 '.. ��ity THE FOLLOWING COMMENTS APPLY TO AND BEC ME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER -(1(7/ •S. 4/ 7 Z 1. NO CHANGES WILL BE MADE TO PLANS UNLESS APPROVED BY ARCHITECT AND TUKWILA BUILDING DEPARTMENT. 2. ALL PERMITS TO BE POSTED AT JOB SITE PRIOR TO START OF ANY CONSTRUCTION. 3. ALL CONSTRUCTION TO BE DONE IN CONFORMANCE WITH APPROVED PLANS AND REQUIREMENTS OF THE UNIFORM BUILDING CODE (1985 EDITION), UNIFORM MECHANICAL CODE (1985 EDITION), WASHINGTON STATE ENERGY CODE (1986 EDITION), AND WASHINGTON STATE REGULATIONS FOR BARRIOR FREE FACILITY (1986 EDITION). 4. ELECTRICAL WORK TO BE INSPECTED BY STATE ELECTRICAL INSPECTORS AND ALL REQUIRED ELECTRICAL PERMITS OBTAINED THROUGH THAT AGENCY. . t 4, City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor September 28, 1988 Fire Department Review Control Number 88 -298, 88 -299, =-317Q (513) Re: Parkside Townhomes - garages - 6530 -6532, 6534 -6536, 6538 South 153rd Street, Tukwila, Wa. Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) (UFC 10.301b) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinents, or set on shelves (NFPA 10, 1 -6.6), and shall be installed so that the top of the extinguisher is not more than 5 ft. above the floor. (NFPA 10, 1 -6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.301) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) 3. An approved fire alarm system is required per City Ordinance #1327. An approved automatic sprinkler system may be installed in lieu of a fire alarm system. (Plans must be submitted to the Fire Prevention Bureau for le* City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 /90$ Gary L. VanDusen, Mayor Page number 2 approval prior to installation.) A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1- 2.4.1) (UFC 10.301) 4. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Yours truly, Gay The Tukwila Fire Prevention Bureau. cc: T.F.D. file ncd TO: FROM: DATE: SUOJECT: City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433 -1800 Gary L. VanDusen, Mayor MEMORANDUM - .. Ii. RPrky Davis November 8. 1988 RPvisinn of site plan rages) As the result of Planning Commission review the site plan was revised to combine garages 6534 -36 S 153 St and 6538 into one building (3 garages). Application 88 -300 was voided and plan review /building permit fees adjusted accordingly. See application 88 -299 for adjustment. (10 /T2.MEMO) .4 City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433-1800 Gary L. VanDusen, Mayor NOTICE OF DECISION FILE NUMBER: 88- 14 -DR: PARKSIDE TOWNHOMES (GARAGES) APPLICANT: Schneider Homes, Inc. REQUEST: Provide five garages with two parking spaces in each structure in front of townhouses. LOCATION: 6531 and 6537 South 153rd Street, Tukwila, WA The Board of Architectural Review (BAR) conducted a review of the request on October 27, 1988, and recommended approval subject to compliance with conditions. The BAR adopted the Findings and Conclusions contained in the Staff Report dated October 20, 1988. Any party aggrieved by this decision may appeal the decision to the City Council by filing an appeal in writing with the City Clerk within ten (10) days of the above date and shall state the reasons for the appeal. MH /sjn Jack Pace Senior Planner November 4, 1988 BOARD OF ARCHITECTURAL REVIEW CONDITIONS OF APPROVAL File No. 88- 14 -DR: Schneider Homes A revised landscape plan shall be submitted to the Planning Director for his review and approval. The plan shall include the following: 1. Additional trees and shrubs shall be planted to enhance the sense of enclosure in this space as shown in Attachment B. Extend landscape islands as shown in Attachment B. Revise sidewalks as shown in Attachment B to improve efficiency. Provided extruded curb or wheel stops in open spaces a minimum of 2 feet from sidewalk /landscape area. Relocation of handicap parking space to provide accessibility to sidewalk area. TO: FROM: r6A-� DATE: J1-P-86 SUBJECT: (T City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433 -1800 Gary L. Vanousen, Mayor MEMORANDUM atoix.6 # 5 '/'l - 9-026,-8 S guAat, evanp,i, 12. 00 i/LA-6 6,4.6ocia/ct 007)/1.2.2 . � �� � CaZ/ i' A ti' Ox .2Q ¥ & - WO (10 /T2.MEMO) Cityof Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor September 28, 1988 Fire Department Review Control Number 88 -298, 88 -299, 8S -9-ifr (513) Re: Parkside Townhomes - garages - 6530 -6532, 6534 -6536, 6538 South 153rd Street, Tukwila, Wa. Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) (UFC 10.301b) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinents, or set on shelves (NFPA 10, 1 -6.6), and shall be installed so that the top of the extinguisher is not more than 5 ft. above the floor. (NFPA 10, 1 -6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.301) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) 3. An approved fire alarm system is required per City Ordinance #1327. An approved automatic sprinkler system may be installed in lieu of a fire alarm system. (Plans must be submitted to the Fire Prevention Bureau for City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor Page number 2 approval prior to installation.) A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1- 2.4.1) (UFC 10.301) 4. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Yours truly, ✓yl The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd ORDINANCE COMPLIANCE - PLAN CHECK NOIES Sheet I ot Date: R-27-85 * 8c4.9)-2.18 12(1. OCCUPANCY GROUP V‘ -1 __Ili --.1._&14cgtieta. I(2. TYPE OF CONSTRUCTION " 3. LOCATION ON PROPERTY BLDG.HT./ #OF STORIES FLOOR AREA 06.7-OCCUPANT LOAD NR. 431 4. , E) 1 I .. • AjikagA, )44•COC±R) ki&DEAAiLt Ai Zallte NOP RIONT.1110.1041Ir orem a cterad4A- *Cal MIL xviarAsumword• DETAILED REQUIREMENTS Au--vtaexai el. OCCUPANCY TYPE IF CONSTRUCTION V-N OK, 4-14ieow414-our w maltANNNED 12A-um off-. GAvAoe- (4/ 12" mx-x 041+ e#;.-EXITING SIUQA 10. CODE R EG S ENGINEERING REGS.& REOMTS. (312. COMPLIANCE W/ 0,16 z43€-2,c, c,W,54N 3-2)(10 atocte al& COMPLIANCE W/ CHAPTER 51-10 W.A.C. CITY OF TUKWILA Budding he nteon B . DING PERMIT APPLI TION 6200 Southcenter 80��1�„�rd � Tukwila, Washington 9e188 '(206) -433 -1849 (0530 — 6953a (5 53.t Site Address,;! , '.j ;-;� Suite# Project Name /Tenant � .���;t�, Towthcvne,5 ; 1 Valuation of Construction -,,t�% %e Assessors Account# ,;2g5ygp Property Owner Sc-, r, (- n ,Yy H s Z N G Phone Address (Q 5 1 0 11 `I' v K Applicant Address Architect /Engineer Address Control # gq Floor# —0 .250 X17 Zip 9asc iI Phone 4S' ::14"7/ Zip 9i' /gg? Phone 2_./ 57 �4 7/ tI Zip ?s,/,,y7 Contractor r License# )j1 ;),E4 Spc Phone _. �' . 47/ Address It Zip 9s/ s s' tI Class of Work: ❑ New ❑ Addition ❑ Tenant Improvement n Remodel (residential) ❑ Reroof ❑ Demolition ❑ Interior Demolition ❑ Other Q- cts.• Describe work to be done (!1.,-ro u,- Ofgm ax, 0-1L q %- z )-,_ ,C 4r > - 7 Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building ¢;.7_.. Square footage of tenant space Building Use CIC;S —I f1, 7 Lit-/o Will there be a change of use? ❑ Yes 1S0 No If yes, describe change of use, including square footages of changed areas Will there be storage or use of flammable, combustible or hazardous materials on the premise or area of construction? ❑ Yes] No If yes, explain I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK. Applicant /Authorized Agent (signature) b fl s, t- ,,� .,�, Date 9- ( )- (print name) ..1 <;, kr c, ',dam C" Contact Person (please print) r• Phone z4 U .2.417/ FEES: Building Permit Fee Plan Check Fee Bldg Code Sur Charge Energy Sur Charge* Other *New construction on y 2 1198 SQUARE FOOTAGE /BUILDING USE INFORMATION• OFFICE USE ONLY VU-w Fee, MX3 an (000/322.100) (000/345.830) (000/386.904) (000/386.907) ( ) TOTAL $ 3/, DO Receipt# t2 3s lf Date Paid .5q,00 Receiptf- 35Lj1J Date Paid 3.50 Receipt# 3 S i Date Paid it _ io g1 15.00 Receipt# G3 S"is Date Paid _ to-ai Receipt# Date Paid ,laszO (OWES: $ qq, 50 Square Foot..- of Entir TOTAL TRACKING DEPT. BLDG FIRE DATE IN DATE OUT - 'r -26 -8f COMMENT Approved for Issuance ype o onst. To Mahan: Date Approved: Oi-ck-M Approved (Initials) Per letter dated l -)7.Y-' Fire Protection: ❑ rinklers ❑Detectors PLNG PWD 1( 10-0 dl- 8`- 68% Approved (Initials) :MAR ❑ LAND USE /SEPA CONDITIONS Zoning Sets:— N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: t I? 19,, (((('Q;; Approved (Initials) Per letter /plans date I\/oc•-s- R -(4' U tI Vo -" CITY OF TUKWILA , -7 TuOM11o�,thcantirtooulsaar9 B' "I.DING PERMIT APPLE . \TION Control $�'o Q (206) -133 -1849 to ”H — (o536' 0 (53 St Site Address 3,j -x„5. ,3-.s ue Suite# Floor# Project Name /Tenant 11:„,-,k... T 4 A Valuation of Construction 67 ": Ad 3s ?I' s count# 2l%5C/Qp —pj5p Property Owner j,J ),, n e. ,,_4 e ,r. }{ r, fyy C S N C, Phone z_ y g I .217 Address 6 S 1 U r:- L_3l.,4-., El 11 'r v iC Zip q is' 6 g S' Applicant II Phone 4 s' ` 4/ 7 Address I i Zip 9 g / g S' Architect /Engineer l i - Phone -. :1 f 74 7/ Address i I Zip 9' S'/ g�2 Contractor ti . License# 'F)(11-1N EJ ,q 54,iThone Z Y r . .117/ Address 0 Zip 95/ SS' Class of Work: New El Addition J Tenant Improvement [] Remodel (residential) Reroof Demolition Interior Demolition Other 0- 051ny Describe work to be done - - ,,„.- Qv - _ _5i.r. q p b] Q , et.lcite ' Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building ;j -e,--,e,_ Square footage of tenant space Building Use ( ZCxu,r iCh/i(p/ Will there be a change of use? Yes 11 No If yes, describe change of use, including square footages of changed areas Will there be storage or use of flammable, combustible or hazardous materials on the premise or area of construction? J Yes Q No If yes, explain I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK. Applicant /Authorized Agent (s i gnaturert) cj , 131,),,N;k14,,%...) Date 9- (90- c.S'rS' (print name) \--a., 1. Sch.r kk. ., .4e (- Contact Person (please print) k e ' c.4r n e. k8 C r Phone z4 2.'1 7/ OFFICE USE ONLY I/c C ►'7l /Fee CV C)1- iv'&' FEES: Building Permit Fee (000/322.100) S K L//)o,„ ! Receipt# Date Paid Plan Check Fee (000/345.830) AL ),a„w0i ♦ Receipt# 55 YL// Date Paid Bldg Code Sur Charge (000/386.904) - Receipt# Date Paid Energy Sur Charge* (000/386.907) /r,,(,3 Receipt Date Paid Other ( ) Receipt# Date Paid ',21-11 ,50 *New construction only my TOTAL (OWES: $ /8150 ) :,1.1:;88 ( s p s3. vv #r5 v P /u� SQUARE FOOTAGE /BUILDING USE INFORMATION, Square FaQtaae of Entire Building: FLOOR USE /Occ Type SO.FT. UGC LOAD, USE /Occ Typo SOFT. LOAD. USE /Occ Tvo% SO.FT" OCC roan TOTAL SO.FT. TOTAL OCC. •' TRACKING DEPT. DATE IN DATE NTS� BLDG e- 0-7Z- , 8 a 26 _8t Approved for Issuance , -: !/ 1 Type of Const. To Mahan: Date A. 'roved: R "-g° ! 7,7 -1(6 ' pproved nT ti a s •er etter 'ate. - 7,sr1- Fire Protection: • sprinklers 'Detectors ) PLNG / 'pprove' nitia s • : • ,'i •'I 1' Zoning Setbacks: N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: PWD Approved (Initials )4/ Per letter /plans dated A'1/0 'i CITY OF 1u!UILA NIL Aulldinq Olvlston F� •fl_DING PERMIT APPL. , '�TION .�� 6200 Southuntlr Aoul /vud ! . Tukwila, etee Control # r� %MP_ 1 84o 0533' (53,t V 0 Site Address fL��4►.lc -�-6 Suite# Floor# Project Name /Tenant r cas-.. -.. TOIOd hUrJe6 4P A Valuation of Construction .;2 6/4 Ili Assessors Account# : I. i !./ —I. / Property Owner S,-,k ,r, e '.A H r. ft el r v N s Z 1VG Pho e ,- q g :21171 Address (o 5 1 U r•- ,_,.zil.... -' `' EI v Tv K Zip qit S Applicant %I Phone ,` •/ . / 7 Address % ■ Zip 9 g /' g' Architect /Engineer Ii Phone 2. 4 g _24 71 Address I 1 Zip '/ ' ' Contractor t 1 . License# S(.1 . N.1 £1 ay spcPhone Z.i.' 20/ Address 0 Zip 9Y/ S h' Class of Work: (] New Addition • Tenant Improvem= Demolition Interior Demolition t [J Remodel (residential) [] Reroof • Other 0-,a Rth _ Describe work to be done Q 1 - a '� 4..251 ' Type of C. s . (UBC) �cc. Group (UBC) Square footage of entire building A„me —> ,r Square footage • ena(t sp ce Building Use - . ..= W1,1 here b. a c f& nge e? [] Yes ED No G f ed a �;, If yes, describe change of use, including •uare footag 1� Will there be storage or use of flamnab e, co4usti, t or�h.z: dous mil a ls on the premise or area of construction? [] Yes Q No f eyes; jhxp • I, • vilik I HEREBY CERTIFY THAT I HAVE READ ' 0 EX ED r IS .PPLICA ION AN KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPE' Y OWN RR^''-55 AUTHORIZATION TO DO TH •S WORK. Applicant /Authorized Agent (sig ;tore) s31.1) 1 ���lt\>-.x.) Date 9-, f:'- 6- "'S? ( p r i name) a. IQ, S c• h. r∎ o. ',d t= C' Contact Person (please print) c „h_ r Q ■C4 r- Phone z'/ ? ?'-1 7/ OFFICE USE ONLY V(tf0 1 D)1 /FtC CC /c5 04 ,2e4/e4"../ FEES: Building Permit Fe (000/322.100) $ Receipt# Date Paid Plan Check Fee (000/345.830) Receipt# .34'/ Date Paid Bldg Code Sur Ch.rge (000/386.904) X Receipt# Date Paid Energy Sur Char.-* (000/386.907) /5-.0e) Receipt# Date Paid Other ( ) Receipt# Date Paid *New construction o ly TOTAL )5 5O (OWES: S ) �88 1 SQUARE FOOTAGE /BUILDING USE INFORMATION• Square FQQtftae of Entir- Buildina� FLOOR USE Occ T •= SI.FT. -M. •,D USE 0 T ._ Si FT O�C�C LOAD, USE 1 T •, 1 FT OCC III TOTAL SI FT. TOTAL OCC. • TOTAL TRACKING DEPT. DATE 'IN DATE OUT COMMENT BLDG 4 -22 -.% q_26 _ef 'pprove• or ssuance '" IP' ype o onst. To Mahan: ,• Date A..roved: R q-27-88 ., c1':1 i- . pproved n ti al s) 'er etter •ate • 7 -2, - v 7 Fire Protection: p . ri nk l ers ,,Detectors 6/3 r,PLNG Approved (Initials) ❑ BAR [ILAND USE /SEPA CONDITIONS Zoning Setbacks: N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: PWD ir Approved (Initials) Per letter /plans dated FLOOR PLAN ROOF PLAN FRONT ELEV. M. ONT ELEV, EL V.. GARAGE TYPE ; GARAGE TYPE 3 ALT A p GARAGE C GARAGE D (SIM.) GARAGE E SIDE ELEV. GARAGE TYPE 2 SIDE' ELEV., GARAGE TYPE 1 GARAGE F2 CITY OF TUKWItA APPROVED GARAGE GARAGE F1 GARAGE 01 GARAGE G2 ARCHITECTURE PLANNING AND INTERIOR DESIGN AVE NE AND PICKET FE DETAIL `'NOTE: If the microfilmed document is less c]-ear than this notigre, it is due to the quality of the original, document.