Loading...
HomeMy WebLinkAboutPermit 2346 - TexacoCN -82 -,222 BUILDING PERMIT CITY OF TUKWILA C PERMIT NUMBER � �� 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 98188 DATE OF ISSUANCE August 2, 1982 EXPIRES February 2, 1983 JOB ADDRESS 13138 Interurban Ave. So., Tukwila, WA 98168 LEGAL DESCR. LOT NO. BLOCK TRACT CX SEE ATTACHED SHEET OWNER Texaco Inc. PHONE ADDRESS 13138 Interurban Ave. So., Tukwila, WA ZIP 98168 CONTRACTOR ESE Corp. PHONE 535 -3112 A1011 Waller Rd. East, Tacoma, WA 98446 LlESEGON235 QA SST 254 258 BUILDING USE Gas Station CLASS OF WORK ❑NEW OADDITION ❑REMODEL OREPAIR MOTHER (Specify)Tank Installation BLDG. AREA 1st FL. 2nd FL. BASEMENT GARAGE DECK MEZZANINE # OF STORES TOTAL S.F. VALUATION I CERTIFY THAT THE ABOVE INFORMATION IS TRUE AND CORRECT, THAT THE APPLICABLE CITY OF TUKWIL REQUIREMENTS WILL BE MET, AND THAT I AM.AN)AU)FHORIZED AG (JT FOR THE PROJECT. OWNED AC'ENYS'i JA�fIRE FEE DISTRIB. BUILDING PLAN RVW. 10.000 52.00 34.00 DEMOLITION BOND OTHER TOTAL 86.00 COMMENTS: TYPE CONST. OCC. GROUP OCC. LOAD FIRE ZONE USE ZONE AUTO SPRINKLERS REQ. VN M1 NA 3 C2 OYES aNO THESE INSPECTIONS ARE REQUIRED BY LAW 1. Driveway 2. OK to 3. Roof 4. OK to 5. Wall- 6. Structure approach and pour footing sheathing enclose board complete and/ slope and /or and nailing framing nailing or OK to foundation OK OK occupy FOR INSPEC�.TIQN CALL 433 -1849 ECG , BUILDI FFICl9(L. CITY OF TUKWILA BUILDI FFIC L, CITY OF TUKWILA THIS PERMIT MUST BE POSTED CONSPICUOUSLY ON BUILDING BUILDING PERMIT PERMIT CITY OF TUKWILA NUMBER 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 98188 c DATE OF ISSUANCE 2, 1982 EXPIRES February 2, 1933 JOB ADDRESS :1..tit :, interurban Ave. So., Tukt,f"ila, WA 98168 LEGAL DESCR. LOT NO. BLOCK TRACT D. SEE ATTACHED SHEET OWNER -.:;4,4';',C0 ihC, PHONE . ADDRESS . 1313 %ti Interurban Ave. So. , Tukwila, WA ZIP 981E8 CONTRACTOR .:.Sl .COriy. PHONE 535 -:112 ADDRESS • :1,1 i.,1.a, I;("2.1'1ei' 1:u. East, Tacoma, WA ZIP 98146 LICENSE NO., E;.,7?'.G ;.f35 (IA SST NO, C600 ,254 2518 BUILDING USE on CLASS OF WORK 0 NEW 0 ADDITION ❑REMODEL ❑REPAIR I-s]OTHER (Specify)" 1aClk Instal li1Lion BLDG. AREA 1st FL. 2nd FL. BASEMENT GARAGE DECK MEZZANINE # OF STORES TOTAL S.F. VALUATION 'N; I CERTIFY THAT THE ABOVE INFORMATION IS TRUE AND CORRECT, THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE MET; AND THAT I AM AN - AUTHORIZED AGE T FOR THE PROJECT. • OWNER`/ AGENT: SIGNATURE FEE DISTRIB. BUILDING PLAN RVW, DEMOLITION BOND OTHER TOTAL 86.10 COMMENTS: TYPE CONST. OCC. GROUP OCC. LOAD FIRE ZONE USE ZONE AUTO SPRINKLERS REQ, r 1/ ;'•I 01 _ NA ;; (%' ❑YES ,I�,NO THESE INSPECTIONS ARE REQUIRED BY LAW 1. Driveway 2. OK to 3. Roof 4. OK to 5. Wall- 6, Structure approach and pour footing sheathing enclose board complete and/ slope and /or and nailing framing nailing or OK to foundation OK OK occupy FOR INSPECTION CALL 433 -1849 BUILtI ,OFFICIAL, CITY OF TUKWILA THIS PERMIT MUST BE POSTED CONSPICUOUSLY ON BUILDING • •••••••:).r,..cr • .6%,"..,>% '• • •', • -, • . . ,WIT'.01.144. ..1.4,1•••••'. • . • e• ;:t • ,:•4:'%:,•• -.4 • •• ';•••: 1:•:' • '; .1-.7•••• .• • • ; 51). • l• " "% • ' 1.* • *:1 -•••4 4-•* .••••;F'. t• "••••:7:-:`. • -• " • 1••••:•..., . • •••••• • :• • , • . •.,. • • ..*. • I...-. a• „„- • • .!.. • ••*: . „„, /.! .• • •••-4t.." ; •'• , , • - ••• - -;'••• .4 • ,t1 .F.7.±:7;• ' > • •"••• • • • .: • •_.; ; :I P.4 s;.; ••;.• • • • ' • •*1 f . • • ITC e :r-- i • • ...• • . • . • , • !....c... • . ',... • • • :•• • ... • T. ...:•-• e:x..;...tt•----.- • - ' ::: ;,-.. j• •I''''''''':":'"••°%'.. ••-:-.." • . ,...,, , Ft ....d. , • • , r: • • *is, .: 4* • • ••• • '''4'1 ...' • • :• * ••'"•." •s •* .."' ••• ■ ..t'...•`• t••••• • " • ••• • •• ' •" -.• 4,:•, . ' . •••• ' •- : . ' .r , 4 ' ' • . . ' , •:•• : -'. ' l'• .' . , '' 4 ••••••• "•,....:•." •:` '0 - t"..ori4•:/: • •••••.A. •C• •■•••;-•":76.- '414:4;...0.:.7••1;:l.;11•4..V.F.,."4.:1'70 •! • : •• .:• . .; .. ... J••••••••,t • -1,' i't •••-•• * •;j't.'"•.',e's' ',•F 4 ' .* •• c.:,• ,-.':':. ;47. ""•.‘r % .7,- ' t .:: ••-• ""',`4: ; J.". 4r,•,. • •'•••••;•:•-•,.....•.!'•%-:15-.'<••••%'-'' '.! ..* .I,' ''' • • '• : •••••••-• • .` • 1: • ;,•'770, s"7- -TrP•fte %elk. : ..1 45,4;7 ' , •'L''..-!`---71•%.--..2• •I•14 • •••••••• •::: ':-.: - '-' :•:' '.. ■••1' ' •••••"1-7'.1.:'•.r1 • •', 7.7 ::- 7-•ii.v:i ....§. - : • --r-- - • • .:-.=•:,22:.:*.•:‘,-zu,..., 3-...„,. ._•!,..;.r.i.:---.;•_:;•:,--,:- ? , • :.'..,-;.; • 4.• .4:.-...1!...;•(:,:•^ ..„.‘i .t: ,...,•••••,.;: ,..; ,,,,,.:„-,,,f,.-..,....,•-• .....-..,;:.......... ..,.... ..,$ ...,-,:1, •:.•: ..u,...z. ,...--, ••,-;:„.• . 1 3.....f,,,-.:,,,•40.-- --i f7t..,.--- - e.- - - ' ' • • ..7,-....• ,..‘ - 74. • i . ,•. ... .. ,. ..It....ie,,, „I.r!, ...*.,..., 7 •••;,":,7:•:::•Pr.2"•,, •,;•!...;•••4114.•••,.:::".',..: y . •;••••••.,,,,;',,' • i ••••••••■•..•'''" .. '''■••••• ‘0: ••••••;■: •• • • "Met"; •"` .. • ..,„ - • ;. r - ;:•%..• • z•.; • r: • • % • t. • • a • • • • . 1•• • • ••••P'''•••4••''''':•••C'LL.i• • ■•••:••••"4...ett!.4q.......!`,.;•• t " e.'• • • • • • • • 4..e•-•;,..r.tt I % • - •••• •, • •' :•• •:"; •;• , • 1•• *•• • • , . .. .. -.3. ---. ‘..,-..?...• • - ., • %•••••'• . . • .....,..;• ,, •••• „ .• • 1-.M.:-,41...- :::- , - . ,• ....-. - . •• ::,.:' •:. '-',. ..7.....-. :: - .,•.;,!‘..-.--•,:'•-2L... •••• ;;-.4 •-•-•:.Z''.7.7%...:;. •:•%.,..;•• ..., .4 *'•••••'•'•:7C.40';'';!;:' .7' ... ' .': :7 C•;;: • • t- • - ' .. • . k'..n.:".:••,..:2.•;•::::4••••••• •••• ...' • i...: ......• . :4••■••••".•••::;;;r:r7:•••:. ,.••••:•$•."=••:•••••"rit.:••• •• • • • .•""1/4, • . • • • " ••• •-• • •••■•:. . 3-..-x.•;:a • % ..!:,...!...•- • • : c.: ; .... -,-;4•„%t-•.:.‘r-a-?!...q&'WP••,•.:_.-7 'ir;•:.A..i '"C:71',......,::-.''.1:'.•-•'•'1■.Z.,.'.164t..;:•3. ;•••:-C,O......7..:1••••--,".:,'„._ :,•••%. t•-;_4":•..;',7•;::::_±,-.::: ::•.2..": ':93,15t. a,,,„;,4,,,,.. Is ..•.a.■,t.,•L .;;•,.;,-::.;7,S...•;6',..;'i.1.474"...Z;'A. 4st, • ''' -:4-::,---ez. ti.4;';-:rif■e.:/-'7•%;::•4;S"'S'':''''',4.:■.7.4,-Cr#414:-L."..-'7•••7'4.11:4:."'...*...- ....', ..-4.• -**"..•- _,_.ty :1•;-"*"...- r:"..= • '••••••••• ..r.' • • '..1.1.:.= . .f..., .:1..ez..- t...•-°1- -te. ..."1 ••• • tr..... • .- ':•• • 4' •,..., ' • .. . .. > .. .1. , .,,,,_, 1**••• 4 ;01rje:•4.••■•e•Yr.:47•44i :1.... ..i" r..:;•1•?2.4 •;;;;•••••:',.• ' 0 :r•-'•',:■ •'""••• '..4, .; "'I ....'• '•• • • • ••• . .'• •••- •;T:rt•7•1•,* A", ell; :•*, '1..4*;'r4k• "*...rt . ..'.4.1.,..r, ... '. % ■••::••■ i--.2.-t:441. 4-41".i'''Or-r---''''• ."' .'`...- ..." 's. .:':itt- • • 4 • ' ----, r:;••.-ty" -rri 2 t'-:.nM:••••-al' --- - 4...r:..i`-':ftgg• •2‘04:2,:ftz.:;-"4-i.g....;;,, ;•.-:;...w2tc,:i. t-v.)i 4-7.: •„., ,. „ • • rtr.4,7 ,:toNt....,,r-=‘-`7A • • :•'••,,,.•-•-%,,,v.k •t„,;" ' . , • 'EA, .1„ • •••••••••• , , +,.•• • ••• .2".• #•,/ kr#1••:•/•;:'7":54.•-•;.:::'14.Z.It .414••42grgt:P.''''"'S :'"•';;'114.7.1.4.1tt.' 4 i• .01 /17:: • -4;1: t.03" t4:* •i'.'11; • 4..4' • • ••••-:, $ri v.r.zr• • • 1•4r t•VArs- -• • •";C•41:4•Pin:,•:••.•::.• Ar... 6.7 • 4.3' j! ••• t••■•••••• ••• '..!•:•• . • • ..*•• ;••••,1.,:t ••• • :AO • .•••••••Kt,ift C-1-11...14.-.4. •, . . tn• . " •••••• 4.•• <.--).?;-;' ", • .*".`t •••F'1".1C1?••••••• ••‘: 1:1:4i":!•9 .•• A , . U. 1:••13 • ; '• • . • •• • •:•1/4.1•7•- • -1:- • •••1.1 ••• t- •••••:,`'.' • . .‘• • x. • • . • .17 • • S.• • • .1- 'T • • • ■",,, • •••• r••;}•.17;•.„,„:11:•-• •-: • '1 •'•• • 1 ;4'5'1'4: r. • • • = •■••;::4-. - • P •c411,4f.*,•••"at•T;'..Ir'i. rti:•".5i • ow:4, •••••••7 , r•r•• •I4.: • • • • • • .1 • , •-• • •"*Zei, 4, LA • r•••..0.7c.,..1).•!..1. • 7.-;%•••• . . -• • • • . • • i r lit,:,:i7.;•„•,.: le: '...s:••, ,•-,•.,i''.•• ...41.0:-.. • 4,4%ir • :•• •C' . • kj-Is•:.: 44.7 % • - • 11 • • lir., • - ••• T:.•• •• 4 ■•••••••.7.„,.• Pais,4,74^eL..".,1 ■.C1, 4,W.7,•±....."Vt•••• ••• ■••71.1•F‘t••../.7 •r- ••••••••...."•'•••... • •:J:••• .1.7444. •'.•• Zii,•,•■•-.23•• r44.4;;Ifk;.• '41 s. nl V: • kr., •Ne,0-.....0 7.44 ta e:••", •":1•1:•t; •••••;;,kiYa•'•-••U• • 1 • •••••••• • „.".." 44. • • -1/4. • ^ • -1/41.1•4?-: gr„,3•R;•'''';A,::.a.:•-•` '4; • • • '••• - "•.'441 •LiC-L• .0%.y riCol• pa:" • •t■.-rt.;;.:14:tk.I.v . • - ,%•••;•;::::L;' • • „in, , • • •r..* ,;••■••••:•• "...,..11^ 4 ••:0•1;,*.t ,101 ■•• • • ••••'.. • • . • .:....,2.•...."1•14.7.11:.t•ti•:;4:?..17 • %-"•■-•••i•-.•-• • •:` .".* • - •$••.: . d•••• .• • • • • 'e • L,•••.4•7•:14 • • • 1/4: • •"'.:.;12;;:V.I;t44,;.-'...„..tiairx.cc..,f , •:;,4" • ••/"•••'••••!•••;, e....4.4,'*".• i • • r ••••••■•••••••,•';',..17:•• :".%**":••,;••••::.7i• •4r.".• ••"*.'"•••• • •••••1•;••1 '•••' ••• ••••••••,,t P.r.;•■•:10141r: 4.• • ..061:, ••• * 4••••,;,•:•••••.•••••••••...,•••• •tt..••:.,••:,,,,a•• • • 1..40•`'" ••••''•••••• • 27:1. .0i..1",...IL',7,?;;;."Z''.'•• *•:•'!*:,'•,••;•:•;‘•:: *4'4 3' r •• ••• ••• i t.gia , r••• .••• „ ••••-• .c.t• • :••••1/4••!*•• „Al: :i• % • • ••• • ...r:_;... p.,• • • ," '• ••• •.- t• • ••.,• • - • .;• i. l•ef : • - • ; •••••:.r.;'4".$:•`et.•"11:At•••:.e;•,;.i••••;••:•••• ',';•••••• : Y0%. '' • -••••'•"-" ' • • ..".*"' ".st ••'`•••••••••••••. • :•••"•., I t...t1.74-.:rz. • t : •• a; sc • • *.• ••;- • • • ';•• .• •:t• ••••.• '1••• • • • • • • • • • .• .."-•-• !, • :e .2; • 7 ' • . • . • • • . • • r ' ' .. ' • . .. . - '' Ste • ; ' . - - . . • ' ' - - . • • •• ' • ' 1 • '.".` •t•..' • • • • -- :,- ; .4;;:l........-;:' :',,..- t: • • : :,.. .„ ; , .. ,. .. .: ...... r • • • -.....• I..; .• ' - •• • :-•,. . :.• • ... • • - - • • • • !,...:: - .7 ' - : • ••• - . t:. ••• ,•,' .v...'•'..*:, - ' , -• • r,...- •.' -` • : . • .." % :. -'.. ' ..: : . '7:: ,:•;,... ., • - '.4.:;;.. 2- ..• . ": . , ...-; , . ,:' ;.•-.. 7 '.." • '" . • ' . -: • ..--.. . , . . . . . :,......7: , ' , ... , • ,•:;••• • • , -.,.• '' •i -.. ;.:•;.•••••■•:3:.• '•!:;1 .21 , '..- - .. •■•,..' ''.. : .....• •■ 3- . "•-• .,::: %...: ; ...',. ...: ....... ' ... . :.. : : " . • • ," • - ,,, . CITY OF TUKWILA 1 4;1141 7Ll.)i'Yl4 ix (A CI PERMIT NUMBER - CuN rROL NUMBER '67.�Z CENTRAL PERMIT SYSTEM - PLAN CHECK ROUTING FORM TO: C BLDG, [1:: PLNG, E P, W, �� IRE ri POLICE ___ P.& R. PROJECT, -Teti C) ADDRESS 1.15 DATE TRANSMITTED 7/ )' - RESPONSE REQUESTED BY 51-2 Gam, C.P.S. STAFF COORDINATOR RESPONSE RECEIVED . G 9v � R PLEASE REVIEW THE ATTACHED PROJECT PLANS AND RESPOND WITH APPROPRIATE COMMENTS IN THE SPACE BELOW, INDICATE CRUCIAL CONCERNS BY CHECKING THE BOX NEXT TO THE LINE(S) ON WHICH THAT CONCERN IS NOTED: ■ 1) • 2) 3) 4) u `412A Q 5> r54 6) 575-,-440 7 fl8) r--1 9) 10) 11) 12> E] 13) 14 ) 15) D, R, C, REVIEW REQUESTED C PLAN CHECK DATE PLAN RESUBMITTAL REQUESTED El COMMENTS PREPARED BY ■ ■ C,P,S, FORM 2 '9.113.70.201 , Division 11 `4tFORM FIRE CODE TANK STORAGE, BULK STORAGE Underground: Outside of or Under Buildings general Sec; 79.211. (a) Location. A flammable or combustible liquid storage ank may be located underground, outside of or under a building if such nstallation meets the requirements of this section. The tank shall be so orated with respect to existing foundations and supports that the loads arried by the latter cannot be transmitted to the tank. The distance from Lny part of a tank storing Class 11 or 111 liquids to the nearest wall of any ►asement, pit, cellar or property lines shall be not less than 1 foot. The listance from any part of a tank storing Class I or 11 liquids to the nearest vall of any basement, pit or cellar shall be not less than 1 foot and from my property line that may be built upon, not less than 3 feet. A minimum listance of 1 foot, shell to shell, shall be maintained between underground anks. (b) Depth and Cover. Excavation for underground storage tanks shall e made with due care to avoid undermining of foundations of existing tructures. Underground tanks shall be set on firm foundation and sur- ounded with soft earth or sand well - tamped in place. Tanks shalf be overed with a minimum of 2 feet of earth or shall be covered by not less han 1 foot of earth on top of which shall be placed a slab of reinforced oncrete not less than 4 inches thick. When underground tanks are or are ikely to be subjected to traffic, they shall be protected against damage rom vehicles passing over them by at least 3 feet of earth cover, or 18 riches of well- tamped earth plus 6 inches of reinforced concrete or 8 inches If asphaltic.concrete. When asphaltic or reinforced concrete paving is used s part of the protection it shall extend at least 1 foot horizontally beyond he outline of the tank in all directions. (c) Anchorage. Where a tank may become buoyant due to a rise in the :vel of the water table or due to location in an area that may be subjected flooding, suitable precautions shall be observed to anchor the tank in dace. )esign and Construction of Tanks Sec. 79.212. Underground tanks or enclosed tanks inside of buildings hall be designed and constructed to withstand safely the service to which ibjected. Material other than steel, if used, shall be of suitable durability id of thickness providing equivalent strength to that provided by steel. :eel tanks shall be in accordance with Table No. 79.212. TABLE NO. 79.212—UNDERGROUND AND ENCLOSED STORAGE TANKS CAPACITY (0dlons) MINIMUM NOMINAL THICKNESS OF MATERIAL' Uncoated Oalvenlaed 1 to 285 286 to 560 561 to 1,100 1,101 to4,000 4,001 to 12,000 12.001 to 20,000 20,001 to 30,000 30,001 to 50,000 0.0747. 0.0146 0.1345 0.1793 Y. inch X. inch' X inch' X inch 0.0635 0.0785 0.1084 licknrss tolerances shall be in accordance with the applicable recognized national standard. adequate internal bracing is provided,' /, -inch plate may be used. Tanks larger than 50,000 gallons shall be built in accordance with na- mally recognized engineering practice. Tanks (in this category) tested id listed as underground storage tanks by a nationally recognized testing ency may be considered as meeting the requirements of this section. red tanks shall be approved by the chief prior to installation. Corrosion Protection Sec. 79.213. Prior to the issuance of a permit to install any underground:'; tank, the issuing authority shall be provided with the results of a soil resistivity test conducted by a qualified engineer, if such information is not already a matter of record. If the test shows a soil resistivity of 10,000 ohm - centimeters or less, corrosion protection shall be provided for the tank and its piping. See Appendix B for details on methods of protection. EXCEPTION: Tanks made of corrosion - resistive materials. Tank Connections for Tanks Underground or inside Buildings Sec. 79.214. (a) Vents. 1. Location and arrangement of vents. Vent pipes from tanks storing Class 1, 11 or 111 -A liquids shall terminate outside of buildings at a point not less than 8 feet above the ground level. Vent' pipes shall discharge only upward or horizontally in order to disperse vapors and shall be arranged so that flammable vapors will not enter . building openings, be trapped under eaves or other obstructions or discharged into hazardous locations. Vent pipes 2 inches or less in nominal ; inside diameter shall not be obstructed by devices that will ieduce their, rapacity and thus cause excessive back pressure. If the vent pipe is less; than )0 feet in length or greater than 2 inches in nominal inside diameter, the outlet shall be provided with a vacuum /pressure - relief device or there;' shall be an approved flame arrester located in the vent line at the outlet. EXCEL "I•IUN: Tanks storing gasoline are exempt from the requirement, for pressure /vacuum venting devices, except as required to prevent excessive. back pressure, or (lame arresters, provided the vent does not exceed 3 inches'; nominal inside diameter. All vent line flame arresters shall be installed in accordance with their:. listing. 2. Use of vent lines. Except when approved by the local fire chief, vent': lines from tanks underground or in buildings shall be used for no other.':; purpose. 3. Size of vents. Each tank shall be vented through piping adequate in. >: size to prevent blow -back of vapor or liquid at the fill opening while tank'. is being filled. Vent pipes shall be not less than 1%-inch nominal inside, diameter. 4. Vent piping. Vent pipes shall be laid so as to drain toward the tank(,. without sags or traps in which liquid can collect. Vent pipes shall be: located so that they will not be subject to physical damage. Vent pipes from tanks: storing the same class of liquids may be con -f ? :: nected into one outlet pipe. The outlet shall be at least one pipe size largert;?s than the largest individual pipe connected thereto. For service stations, the capacity of manifolded vent piping shall be suf ficient to discharge vapors generated when two manifolded tanks arc :'' simultaneously filled. The lower end of a vent pipe shall enter the tank through the top and shall not extend into the tank more than 1 inch. 5. Swing Joints. Swing joints shall be used where the vent pipe leaves the tank and where it connects to buildings or other structures. (b) Tank Openings Other Than Vents.from Underground Tanks. General. Connections for all tank openings shall be liquid- tight. All open; ings to underground tanks shall be located outside of buildings at a loca•' .tion free from any source of ignition and not less than 10 feet away frorr,,,c any building opening. Such openings shall be provided with a liquid -tight cap which shall be closed when not in use and shall be properly identified. tlj Fill, discharge and vapor recovery lines shall enter tanks only through:.' the top and shall be so laid as to drain back to the tank. The fill pipe shalt be designed and installed so as to terminate within 6 inches of the bottom.,: of the tank. 2. Openings for manual gaging. Openings for manual gaging, if in•' dependent of the fill pipe, shall be provided with a liquid -tight cover» Covers shall be kept closed when not in use. Each such opening shall be protected against liquid overflow and possible vapor release by means of-a spring - loaded check valve or other approved device. 3. Openings for vapor recovery. Tank openings provided for the pur•;i pose of vapor recovery shall be protected against possible vapor release b) means of a spring - loaded check valve or dry break connection, or other approved device, unless the opening is pipe - connected to a vapor process ing system. Openings designed for combined fill and vapor recovery also 4; shall be'proteeteil against vapor release unlc .cction of the liquid .:: delivery . line to the fill pipe simultaneously connects the vapor recovery line, All connections shall be vapor- tight. Testing Sec. 79.215. (a) Before being covered or placed in use, tanks and piping connected to underground tanks shall be tested for tightness. Portions of the system shall not be covered until it has been approved. (b) Underground tanks shall be tested for tightness hydrostatically, or with air pressure at not less than 3 pounds per square inch and not more than 5 pounds per square inch for 30 minutes. (c) The piping system between the pump and the dispenser, but not in- ! duding the pump, tank or dispenser, shall be tested hydrostatically for 30 minutes to 150 percent of the shutoff pressure of the pump or 75- pound- „per- square- inch -gage, whichever is greater, to insure tightness. (d) Existing underground storage tanks and piping shall be tested for ;leakage at the owner's or operator's expense when the chief has reasonable rt, _cause to believe a leak exists in the location in question. indonment of Tanks r General Sec. 79.221. (a) For permits to remove, abandon, place temporarily of of service or otherwise dispose of any flammable or combustible liqui tank, see Section 4.101. (b) Any tank not" used for a period of 90 days shall be proper) safeguarded or removed in a manner approved by the chief. (c) Tanks "temporarily out of service" shall have the 1111 line, gai opening and pump connection secured against tampering. Vent lines sha remain open and be maintained in accordance with the requirements c this article for vent lines. (d) Any aboveground tank which has been abandoned for a period c one ycar shall be removed from the property in a manner approved by if chief. (e) Any underground tank which has been abandoned for a period c one year shall be removed from the ground and the hole properly filled. circumstances warrant, however, such tank may be abandoned in plat and safeguarded in a manner and with material approved by the chief. (f) Tanks which are to be reinstalled for flammable or combustible lit uid service shall comply with all of the provisions of Division 11 of th article. (g) Tanks which are to be placed back in service shall be tested in a ma: ner approved by the chief. FIRE DEPARTMENT CITY of TUKWILA 444 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 TELEPHONE: (206) 244 -7221 Listed below you will find the requirements for underground storage tanks and dispensers. 1. The tank shall be located not less than 1 foot from any building foundation and not less than 3 feet from any property line. The tank shall be covered with at least 1$ inches of well - tamped earth or sand,-then by at least 6 inches of . reinforced conrete. The concrete shall extend not less than 1 foot, horion- tally, - beyond the tank in all directions. The tank shall be surrounded by well - tamped sand or soft earth. . An emergency electrical shut -off shall be located ::between 15 and 75 feet from the dispenser.. The switch shall.be conspicuously labeled. A : 20 `B -C dry_ .chemical .extinguisher-shall be locate not more than "75 : :feet 1'x-ilia-the dispenser.:'. `'ti5_ry,. Signs ,with 4 inch high letters shall be posted r x : a_: t -��" 'the dispensestating,'N0 SMOKING "• `SHUT -OFF 'YOUR.i'S r�� ` w.. ENGINE. ,,. ,. break- away %fusible linkfittingw.::shall be: to cate ground; level:: :inr` the supply: line to ,the dispenser 1 ' a pressure delivery pump' is used. ~ ; ,-t " 1r, ' ' rtdti - -'- g. . 74 :ti,n t. 4vjg M if f' ��. �t"S' �`9'_.: I � qa.. e...... e tank & vents _:- shallw>thstand au'pressurerr.testtof :; •psi: Piping and dispenser, shall withstanea pressure '' ::test ::oft,:150 f of tthe pump shut -ofi pre ssures<.or;: 75 ._ =ps 1_ ..(whichever is =greater) These tests area toy te' conducted'F -i' prior" to covering' the pies. This office �zs Ito witness h all tests. .col ;+tirs.. 4 ;�i"�y ;, -� ,; ; w FI • .. ., .sr .. 'e -.nom' .'._. i••. �.. .�'".. "i_... ..- . ^�•r11: ?.- .,•: All electrical::.• work - shall" be per - the ' National Electric Code, Class 1;:'Division l: ��` ": t s! {. •t^ .s4:.N ,;:i � ^ `"' ,!` �'in T s??,4,.�^..k` ry', a �( rti �..t Vent pipes shall not be less than .12 feet :high' grid: at ,:least 2.7feet:: above building. roofs;.'shall: vent upwards, MT<; : or horizontally,- and shall: ,not be : located so as to:,--,... allow° accumulations of-vapor in. °or; near- buii"dings. Provide protective guard' posts around the dispenser. (4. inch steel). • 10. A building permit must be obtained from the Building Department. C•ontrul• Number -o oR t) APPLICATION FOR PERMIT BUILDING DEPARTMENT CITY of TUKWI LA 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 98188 433 -1849 R ET000,A 919 $32 8011)114Ci °Err' DATE 7/2A J S (PERMIT NO. WHEN VALIDATED • EXPIRES ' JOB ADDRESS / 3 / 38 , jI(.f`(- e� C./Z L�q A Vim" ` f ^U lLut(! 1.�p�' LEGAL DESCR. LOT NO. : - :: BLOCK , .. TRACT ❑ SEE ATTACHED SHEET . OWNER ,. - t °`;• -r- — r., %c! G ,. •- x. ':'- `PHONE " I ADDRESS 5&..r--- „ ZIP .. CONTRACTOR :ir`5•' ;.µ: :it: :::; - '.” 4-11 i; s::t • -h- w PHONE 4'': •ti 1 ' :af:i :�- ADDRESS / /a,jj /A.A L --E�G_ ' /�f �a .� e--"s~-r-- -=r—A �0 ZIP,- 98-x¢4• :. LICENSE NO N±;'r SST NO..:- BUILDING USE /'1 f TENANT,' ' CLASS OF WORK '• °' ' 4. ,t���i `"-.: • . ,. • ❑ NEW.;-- ❑ ADDITION .^ ' ❑ REMODEL - ❑ REPAIR HER (Specify) T BLDG. -. AREA '1st FL. 2nd FL. •.: BASEMENT `. :?a GARAGE DECK MEZZANINE * OF STORES TOTAL S.F. VALUATION BOND w e. PUBLIC Vs/KS. k r,•; . F 1 NAME OF APPLICANT (PLEASE PRINT) ; +; I:1 ';;i, ADDRESS " PHONE :; „ 'I CERTIFY THAT THE INFORMATION FURNISHED BY ME IS TRUE AND CORRECT AND THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE MET.'- • SIGNATURE OF APPLICANT ' i---- • DO NOT WRITE BELOW THIS LINE TYPE CONST. 'OCC. GROUP ., OCC. LOAD FIRE ZONE USE ZONE AUTO SPRINKLERS REQ.' I DETECTOR M •r • /(/AA- 0._ C 2 o YES I NO [❑ YES [] NO PLAN RVW ,. PLANS: ' SENT RETURNED APPROVED FEE DISTRIB. BUILDING 5Rea!3 . - �f (�j1 FIRE DEPT. '8712-(g2.-- /,11/ '_70, PLAN RVW. • DEMOLITION PLANNING/ SEPA BOND OTHER PUBLIC Vs/KS. TOTAL / / 4 6. `' RECEIPT NO. COMMENTS: 'APPROVED, FOR ISSUANCE. BY CITY OF TUKWILA PERMIT NUMBER - CONTROL NUMBER g i' Z CENTRAL PERMIT SYSTEM - PLAN CHECK ROUTING FORM .pi am 6LW M.4tfeC{ • TO: III BLDG, • PLNG, IPWI 101! IRE •POLJCE P,& R. PROJECT TL CQ) ADDRESS 0/3 DATE TRANSMITTED '74 ) - RESPONSE REQUESTED BY 512 allt), C,P,S, STAFF COORDINATOR G& 9v RESPONSE RECEIVED • PLEASE REVIEW THE ATTACHED PROJECT PLANS AND RESPOND WITH APPROPRIATE COMMENTS IN THE SPACE BELOW, INDICATE CRUCIAL CONCERNS BY CHECKING THE BOX NEXT TO THE LINE(S) ON WHICH THAT CONCERN IS NOTED: ■ 1) iiii* 2) 3) .Drace l T ks pe,e q) ge/OulPW--the,t)1:5' '114.KL4;,(4. F:71)� ❑ 5) 6) 64 57s--44o7 le-- ge)s7lel'erc 8) 9) 10) 11) 12) 13) 14) 1:::1 15 >, ■ ■ ■ ■ ■ ■ D.R.C. REVIEW REQUESTED • PLAN CHECK DATE PLAN RESUBMITTAL REQUESTED ❑ COMMENTS PREPARED BY C,P,S, FORM 2 FIRE DEPARTMENT CITY of TUKWILA 444 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 TELEPHONE: .(206) 244 -7221 Listed below you will find the requirements for underground storage tanks and dispensers. 1. The tank shall be located not less than 1 foot from any building foundation and not less than 3 feet from any property line. The tank shall be covered with at least 1$ inches of well - tamped earth or sand, then by at least 6 inches of reinforced conrete. The concrete shall extend not less than 1 foot, horizon - tally, beyond the tank in all directions. The tank shall be surrounded by well - tamped sand or soft earth. 2. An emergency electrical shut -off shall be located between 15 and 75 feet from the dispenser. The switch shall be conspicuously labeled. A 20 B -C dry - chemical extinguisher shall be located not more than 75 feet from the dispenser. Signs with 4 inch high letters shall be posted at the dispenser, stating, "NO SMOKING" SHUT -OFF YOUR ENGINE". A break - away /fusible link fitting shall be located at ground level in the supply line to the dispenser if a pressure - delivery pump is used. The tank & vents shall withstand a pressure test of 4 psi. Piping and dispenser shall withstand a pressure test of 150% of the pump shut -off pressure or 75 psi, (whichever is greater). These tests are to be conducted . prior to covering the pipes. This office is to witness all tests. All electrical work shall be per the National Electric Code, Class 1, Division 1. Vent pipes shall not be less than 12 feet high and at least 2 feet above building roofs, shall vent upwards, or horizontally, and shall not be located so as to allow accumulations of vapor in or near buildings. 9. Provide protective guard posts around the dispenser. (4 inch steel} 10. A building permit must be obtained from the Building Department. 79.113.79.201, UNIFORM FIRE CODE Division H TANK STORAGE, BULK STORAGE Underground: Outside of or Under Buildings General Seca 79.211. (a) Location. A flammable or combustible liquid storage tank may be located underground, outside of or under a building if such installation meets the requirements of this section. The tank shall be so located with respect to existing foundations and supports that the loads carried by the latter cannot be transmitted to the tank. The distance from any part of a tank storing Class II or 11I liquids to the nearest wall of any basement, pit, cellar or property lines shall be not less than 1 foot. The distance from any part of a tank storing Class I or II liquids to the nearest wall of any basement, pit or cellar shall be not Tess than 1 foot and from any property line that may be built upon, not less than 3 feet. A minimum distance of 1 foot, shell to shell, shall be maintained between underground tanks. (b) Depth and Cover. Excavation for underground storage tanks shall be made with due care to avoid undermining of foundations of existing structures. Underground tanks shall be set on firm foundation and sur- rounded with soft earth or sand well - tamped in place. Tanks shall' be covered with a minimum of 2 feet of earth or shall be covered by not less than 1 foot of earth on top of which shall be placed a slab of reinforced concrete not less than 4 inches thick. When underground tanks are or are likely to be subjected to traffic, they shall be protected against damage from vehicles passing over them by at least 3 feet of earth cover, or 18 inches of well- tamped earth plus 6 inches of reinforced concrete or 8 inches of asphaltic concrete. When asphaltic or reinforced concrete paving is used as part of the protection it shall extend at least 1 foot horizontally beyond the outline of the tank in all directions. (c) Anchorage. Where a tank may become buoyant due to a rise in the level of the water table or due to location in an area that may be subjected to flooding, suitable precautions shall be observed to anchor the tank in place. Design and Construction of Tanks Sec. 79.212. Underground tanks or enclosed tanks inside of buildings shall be designed and constructed to withstand safely the service to which subjected. Material other than steel, if used, shall be of suitable durability and of thickness providing equivalent strength to that provided by steel. Steel tanks shall be in accordance with Table No. 79.212. TABLE NO. 79.212—UNDERGROUND AND ENCLOSED STORAGE TANKS CAPACITY (Gallons) MINIMUM NOMINAL THICKNESS OF MATERIAL' Uncoated - Galvanised 1 to 285 0.0747. 0.0635 286 to 560 0.0146 0.0785 561 to 1,100 0.1345 0.1084 1,101 to 4,000 0.1793 4,001 to 12,000 '/. inch 12,001 to 20,000 ' /,, inch' 20,001 to 30,000 % inch' 30,001 to 50,000 % inch Thickness tolerances shall be in accordance with the applicable recognized national standard. '1f adequate internal bracing is provided,'' /nch plate may be used. Tanks larger than 50,000 gallons shall be built in accordance with na- tionally recognized engineering practice. Tanks (in this category) tested and listed as underground storage tanks by a nationally recognized testing agency may be considered as meeting the requirements of this section. Used tanks shall be approved by the chief prior to installation. Corrosion Protection Sec. 79.213. Prior to the issuance of a permit to install any undergrounl tank, the issuing authority shall be provided with the results of a soil resistivity test conducted by a qualified engineer, if such information is no already a matter of record. if the test shows a soil resistivity of 10,001 ohm - centimeters or less, corrosion protection shall be provided for th tank and its piping. See Appendix B for details on methods of protection. EXCEPTION: Tanks made of corrosion- resistive materials. Tank Connections for Tanks Underground or Inside Buildings Sec. 79.214. (a) Vents. 1. Location and arrangement of vents. Ven pipes from tanks storing Class I, 1I or III -A liquids shall terminate outsid of buildings at a point not less than 8 feet above the ground level. Ven pipes shall discharge only upward or horizontally in order to dispers vapors and shall be arranged so that flammable vapors will not ente building openings, be trapped under eaves or other obstructions o discharged into hazardous locations. Vent pipes 2 inches or less in nomina inside diameter shall not be obstructed by devices that will reduce thei capacity and thus cause excessive back pressure. If the vent pipe is les than 10 feet in length or greater than 2 inches in nominal inside diameter the outlet shall be provided with a vacuum /pressure - relief device or ther shall be an approved flame arrester located in the vent line at the outlet. E XCE :1''1'ION: Tanks storing gasoline are exempt from the requiremer for picssurc /vucuum venting devices, except as required to prevent excessiv back pressure, or flame arresters, provided the vent does not exceed 3 incite nominal inside diameter. All vent line flame arresters shall be installed in accordance with thei listing. 2. Use of vent lines. Except when approved by the local fire chief, ver lines from tanks underground or in buildings shall be used for no othe purpose. 3. Size of vents. Each tank shall be vented through piping adequate i size to prevent blow -back of vapor or liquid at the fill opening while tan is being filled. Vent pipes shall be not less than PA-inch nominal insid diameter. 4. Vent piping. Vent pipes shall be laid so as to drain toward the tan without sags or traps in which liquid can collect. Vent pipes shall b located so that they will not be subject to physical damage. Vent pipes from tanks storing the same class of liquids may be con nected into one outlet pipe. The outlet shall be at least one pipe size large than the largest individual pipe connected thereto. For service stations, the capacity of manifolded vent piping shall be out ficient to discharge vapors generated when two manifolded tanks ar simultaneously filled. The lower end of a vent pipe shall enter the tan through the top and shall not extend into the tank more than 1 inch. 5. Swing Joints. Swing joints shall be used where the vent pipe leaves th tank and where it connects to buildings or other structures. (b) Tank Openings Other Than Vents from Underground Tanks. General. Connections for all tank openings shall be liquid- tight. All opt( ings to underground tanks shall be located outside of buildings at a loci tion free from any source of ignition and not less than 10 feet away fro( any building opening. Such openings shall be provided with a liquid -tigl cap which shall be closed when not in use and shall be properly identified, Fill, discharge and vapor recovery lines shall enter tanks only throug the top and shall be so laid as to drain back to the tank. The fill pipe she be designed and installed so as to terminate within 6 inches of the botto( of the tank. 2. Openings for manual gaging. Openings for manual gaging, if ii dependent of the fill pipe, shall be provided with a liquid -tight cove Covers shall be kept closed when not in use. Each such opening shall t protected against liquid overflow and possible vapor release by means of spring- loaded check valve or other approved device. 3. Openings for vapor recovery. Tank openings provided for the pu pose of vapor recovery shall be protected against possible vapor release t means of a spring - loaded check valve or dry break connection, or othl approved device, unless the opening is pipe - connected to a vapor proces ing system. Openings designed for combined fill and vapor recovery alt uII be protected against vapor release unless "connection of the liquid livery line to the fill pipe simultaneously connects the vapor recovery ie. All connections shall be vapor - tight: 'sting Sec. 79.215. (a) Before being covered or placed in use, tanks and piping nnected to underground tanks shall be tested for tightness. Portions of e system shall not be covered until it has been approved. (b) Underground tanks shall be tested for tightness hydrostatically, or th air pressure at not less than 3 pounds per square inch and not more an 5 pounds per square inch for 30 minutes. (c) The piping system between the pump and the dispenser, but not in- kling the pump, tank or dispenser, shall be tested hydrostatically for 30 mutes to 150 percent of the shutoff pressure of the pump or 75- pound- r- square- inch -gage, whichever is greater, to insure tightness. (d) Existing underground storage tanks and piping shall be tested for 'kage at the owner's or operator's expense when the chief has reasonable use believe a leak exists in the location in question. abandonment of Tanks General Sec. 79.221. (a) For permits to remove, abandon, place temporarily out of service or otherwise dispose of any flammable or combustible liquid tank, see Section 4.101. (b) Any tank not used for a period of 90 days shall be properly safeguarded or removed in a manner approved by the chief. (c) Tanks . "temporarily out of service" shall have the fill line, gage opening and pump connection secured against tampering. Vent lines shall remain open and be maintained in accordance with the requirements of this article for vent lines. (d) Any aboveground tank which has been abandoned for a period of one year shall be removed from the property in a manner approved by the chief. (e) Any underground tank which has been abandoned for a period of one year shall be removed from the ground and the hole properly filled. If circumstances warrant, however, such tank may be abandoned in place and safeguarded in a manner and with material approved by the chief. (t) Tanks which are to be reinstalled for flammable or combustible lie_ uid service shall comply with all of ,the provisions of Division 11 of the article. ' (g) Tanks which are to be placed back in service shall be tested in a mar, ner approved by the chief. Coritrol' Number g:9''e2o'Z APPLICATION FOR PERMIT BUILDING DEPARTMENT CITY of TU KW I LA R� D� 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 4 � 98188 Cr U Tl3K SC 2) 9 1982 8uiLDaG pen. DATE 7/2 .9 / B•� •/ 'PERMIT NO. WHEN VALIDATED EXPIRES JOB ADDRESS 3/3� 1/1.i%�rZ...V/ZL3m,G% AVr'"". l ^VJLLt-(It_! . UW.1 gCa'6 8 LEGAL DESCR. LOT NO. BLOCK / TRACT ❑ SEE ATTACHED SHEET OWNER --/-- .G "3C!•-G, bliG PHONE ADDRESS n ,,.,, LK C ZIP CONTRACTOR f .sC5 . Gca41.i ∎- PHONE .5'35-- .3//�- ADDRESS / ld // //lif(L/ c-d__ b ki5T_ eoAk./:y ZIP P5 47 /-j LICENSE NO FSEC0' 'Z3.,S' SST NO. C bo C) .2_5-4 2 �$ - BUILDING USE 6,6,0 z��9%% / "`���� l� TENANT �/% `'C CLASS OF WORK ❑ NEW ❑ ADDITION ❑ REMODEL ❑ REPAIR HER (Specify) aC BLDG. AREA 1st FL. 2nd FL. BASEMENT GARAGE DECK MEZZANINE # OF STORES TOTAL S.F. VALUATION BOND OTHER PUBLIC WKS. /0 %]%�/ ` L/C /� NAME OF APPLICANT (PLEASE PRINT) ADDRESS I PHONE •1 CERTIFY THAT THE INFORMATION FURNISHED BY ME IS TRUE AND CORRECT AND THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE MET. SIGNATURE OF APPLICANT �- DO NOT WRITE BELOW THIS LINE TYPE CONST. OCC. GROUP OCC, LOAD FIRE ZONE USE ZONE AUTO SPRINKLERS REQ. l DETECTOR -{ - N 3 ❑YES X NO ❑YES D NO PLAN RVW PLANS: SENT RETURNED APPROVED FEE DISTRIB. BUILDING 5,7r aP FIRE DEPT. PLAN RVW. 7) DEMOLITION PLANNING/ SEPA BOND OTHER PUBLIC WKS. TOTAL 4f_• ap RECEIPT NO. COMMENTS: 'APPROVED FOR ISSUANCE BY.