Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG06-018 - JACK IN THE BOX
8 10 S AV l VIIIIMM21I WOE I XOgaH1-NI-NDVf City of Ti wi1a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cttukwiia.wa.us Parcel No.: 0003000106 Address' 13050 INTERURBAN AV S TUKW Suite No: Tenant: Name: JACK -IN- THE -BOX Address: 13050 INTERURBAN AV S, TUKWILA WA Contact Person: Name: ROBERT HITCHCOCK Address: 19606 NE 8 ST, CAMAS WA Contractor: Name: ROMEK INC Address: PO BOX 1659, EDMONDS WA Contractor License No: ROMEKI *175NN DESCRIPTION OF WORK: RELOCATE (1) WATERCLOSET AND (1) LAVATORY Value of Plumbing /Gas Piping: $0.00 Fees Collected: $122.50 Plumbing Bathtub or combination bath /shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain... Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain 0 Receptor, indirect waste 0 Sinks 1 Urinals 0 Water Closet 1 doc: UPC - Permit PLUMBING /GAS PIPING PERMIT Owner: Name: TAX ASSESSMENT ASSOC INC Address: 1777 NE LOOP 410 #1250, SAN ANTONIO TX FIXTURE TYPE AND QUANTITY * *continued on next page ** Steven hl et, Mayor Steve Lancaster, Director Permit Number: PGO6 -018 Issue Date: 07/10/2006 Permit Expires On: Phone: Phone: 360 601 -3231 Phone: 206 367 -5010 Expiration Date:07 /18/2007 Uniform Plumbing Code Edition: 2003 International Fuel Gas Code Edition: 2003 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and /or vent 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and /or water 0 treatment equipment 1 0 Medical gas piping system serving one to five 0 inlets /outlets for a specific gas 1 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 PG06 -018 Printed: 07 -10 -2006 Permit Center Authorized Signature: I hereby certify that I have read and ordinances governing this work will b doc: UPC - Permit City of Ttwi1a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cttukwiila.wa.us p Signature: • ►L a - I Print Name: L 1 t C r R C> b e r ems' - 'S 6 -A-1 a u M Steven AliC1et, Mayor Steve Lancaster, Director Permit Number: PGO6 -018 Issue Date: 07/10/2006 Permit Expires On: U Date: (01 kb�,fD(o fined t is permit and know the same to be true and correct. All provisions of law and mplie. with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date: /// 6 76 S;- t.. This permit shall become nand void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG06 -016 Printed: 07 -10 -2006 Parcel No.: 0003000106 Address' 13050 INTERURBAN AV S TUKW Suite No: Tenant: JACK -IN- THE -BOX 1: ** *PLUMBING AND GAS PIPING * ** City orTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 Fax: 206 - 431 - 3665 Web site: ci.tukwila.wa.us PERMIT CONDITIONS Steven M Mullet, Mayor Steve Lancaster, Director Permit Number: PG06 -018 Status: ISSUED Applied Date: 05/08/2006 Issue Date: 07/10/2006 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 5: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Conditions * *continued on next page ** PG06 -018 Printed: 07 -10 -2006 City or Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions C l I AA Date: 7/70) C PGO6.018 Printed: 07 -10 -2006 CITY OF TUKWIUF Community Developme1/4department Public Works Department Permit Center 6300 Southcenter 81vd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa,us U i� �� /�, King Co Assessor's Tax No.: I1 DO�i°O —O / / — Site Address: /3196- t h Aft ri • Suite Number: Floor Tenant Name: V/ie- / " " 00E New Tenant: ❑ .... Yes Property Owners Name: Mailing Address: fo 3� bet Name: t / Da Telephone: �j Mailing Address: / �0 /� Come , [ jf}mAts o Q a �� t7 hia �j ST? aisle hi" E-Mail Address: e � �`� � F ax Nu mber: 3 ��' � Company Name: ' h4 mertl a ', - Mailing Address: /3 D ae t / e �e- S • eilnen l air-. City State ti Contact Person: f 11 __ ! ✓ �J/ ds ci Day Telephone:a -& 21/40 / � • E -Mail Address: 777/+�'t CS/ ba /I en • etfrP t Fax Number: `gal 2 l T% "}th 5 ' Contractor Registration Number: en/n65/ MCI /4I... Company Name: `! T \ �S on tl4t fl . Q Mailing Address: / / / i et" ` • Die* r / G G y p e • Day Telephone: t) 3, t � C [ ! / 7 Fax Number. /S 1 �s - 5'73. 6 < fe y Contact Person: /t/ l e /Q e E-Mail Address: 4Vy'1�/ • / 'L 4cni Lt nke '7 , cnn • E Wv Mailing Address: sr Contact Person: Sla c c 14 a-eider Company Name: Ons Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** - - E -Mail Address:PM/ Address:`'/M/ rONSWa Q:Mppliutiw\Panu- Applioliau On Lin* -2006 • Pond Application*. ■*inn6: 42006 W San corn 0 Expiration Date: i'2 (fi- el - n City / Day Telephone: �� -••� (� Fax Number: SST. • 000 Existin y B '1'l Valuat n: S LT pirat Valuation of Project (contractor's bid price): S Scope f Work (please provide dytailed ' formation): MorntPh Will there be new rack storage? ❑ ..Yes Provide Ali Building Areas in Squa outage Bglo 2° Floor 3"` Floor �iterior Remodel ddition to ;,: Existing' ttushiie —o- yPe of. ) ccupaney:per PI,ANNIN0=I31VISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq It): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0-Sprinklers ❑..Automatic Fire Alarm iNone Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑..Yes �No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:UOVlicadc WameApphc,zss On Line \3 -2006 - Permit Applirnioo.doe Revised: 42006 m (If yes, a separate permit and plan submittal will be required) ❑ . Other (specify) Page 2 of 6 PlxtureTYPe:. Qty - P'ixtureType: Qty 7 : Fiflu$Type:- [8I EixtureType: Bathtub or combination bath/shower Drinking fountain o r water cooler (per head) W ashi fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain . Sinks / Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Additional medical gas inlets/outlets — six or more PLUMBING AND GAS PIPING CONTRA R INF RMATION Company Name: csyeeut/ e Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Expiration Date: Contractor Registration Number: Valuation of Project (contractor's bid price): S Scope of Work (please provide de 'lednfo ation): O Q:Wpacnionnwonm- ApplWdons On Libel-2006 Appiicnion.doc Revised: 42006 Ni Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quan ity below: State Zip Page S of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). PlumbintPermit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: Mailing Address: Date: /ego. IF I a Day Telephone: L 3 2 Siio SI r AULAS BUILDING OW R U20 ED ENT: Signature: I Date Application Accepted: i `; QMppiieetiauwwm,- Application On Line \34006 - Permit Application.doe Revised: 4-2006 bit Date Application Expires: City it (v$ I State Staff Initials: Page 6 of 6 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003000106 Permit Number: PGO6 -018 Address' 13050 INTERURBAN AV S TUKW Status: APPROVED Suite No: Applied Date: 05/0812006 Applicant: JACK -IN- THE -BOX Issue Date: Receipt No.: R06 -01005 Payment Amount: 98.00 Initials: JEM Payment Date: 07110/2006 04:17 PM User ID: 1165 Balance: $0.00 Payee: ROMEK, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 14494 98.00 ACCOUNT ITEM LIST: Description Current Pmts PLUMBING - NONRES RECEIPT Account Code 000/322.100 98.00 Total: 98.00 7281 07/12 9710 T0TAL. 98.00 doc: Receipt Printed: 07-10-2006 Copy Reprinted on 05 -08 -2006 at 16:07:36 05/08/2006 RECEIPT NO: R06 -00631 Initials: JEM Payment Date: 05/08/2006 User ID: 1165 Total Payment:892.95 Payee: JACK IN THE BOX INC. SET ID: 5000000481 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount 006 -164 868.45 PG06 -018 24.50 TOTAL: 892.95 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment check 207891 892.95 TOTAL: 892.95 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 892.95 TOTAL: 892.95 5260 05/09 9716 TOTAL 892.95 Steven M. Mullet, Mawr Steve Lancaster, Director Prot: P r t li, -1 ,J t of I nspepion: P I t.J A I Address; }3 5c) _ia.lkeirtAvbyte/ Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila; WA 98188 (206) E Approved per applicable codes. Corrections required prior to approval. COMMENTS: Z tor: MX AA � 'rl s ...... s .......,..._... . e Date: 7 —z -dt-, 5 8.00 REINSPECTIO FEE REQUIRED rior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: PrG L !� fie Type of ection: ic ,V Ad ss: tfk • Date ailed: Special Instructions: - Date Wanted: ( � Reques er: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER (206)431-367 Approved per applicable codes. 0 Corrections required prior to approval. O M ENTS: $5 irc REINSPECTION E REQUIRED. Pri r to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. all to sechedule reinspection. Receipt No.: Datk: Pro '9 /[. th1 13e1 Typesf Inspection: y /z14^SiNb 'A./ 5 Ad/ i Am 2 ,,t £Av Date Called: Special Instructions: Date W ted: /-IL -oC, (di? p.m. Requester: • /L) /y N R2 Ph one Ob- -'991/ e INSPECTION RECORD �^'' Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. ?Got, . " s COMMENTS: /a ^Jd 4 .o re. �S Insttor: AAA. REINSPECTION F REQ E Dat / Corrections required prior to approval $ 0 D. Prior to inspection, fee must be 6300 Southcenter lvd. p ' at Suite 100. Call to sechedule reinspection. Receipt No.: Date: ACTIVITY NUMBER: PG06 -018 PROJECT NAME: JACK -IN- THE -BOX SITE ADDRESS: 13050 INTERURBAN AV S DATE: 05 -08 -06 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: t, 6 B i .Ing Division N Fire Prevention Public Works Structural C CAP K�� f1(0 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY`S PLAN REVIEW /ROUTING SLIP Incomplete ❑ Approved with Conditions Planning Division ❑ Permit Coordinator DUE DATE: 05-09-06 Not Applicable ❑ No further Review Required DATE: DATE: DUE DATE: 06-06-06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License ROMEKI'175NN Licensee Name ROMEK INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600485232 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 1659 Address 2 City EDMONDS County SNOHOMISH State WA Zip 98020 Phone 2063675010 Status ACTIVE Specialty I AIR CONDITIONING Specialty 2 PLUMBING Effective Date 8/15/1983 Expiration Date 7/18/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ROBERTSON, LAURENCE W 01/01/1980 ROBERTSON, MONTEREY 01/01/1980 Look Up a Contractor, Electrir or Plumber License Detail 1/2wv Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond #2 Bond Company Name WESTERN SURETY CO Bond Account Number 69027508 Effective Date 07/18/2000 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $6,000.00 Received Date 07/03/2002 Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= ROMEKI* 175NN 07/10/2006 rianun LIC . La As . ......_ ....._ _ .. .. _____ -4 -4- . - -4 _ _ P _ --i i' - 4 t - st -4-4 . t.. .. . • X cm,- r,-.0 313tylm/ ) Cul Us - --+ - --• - _____ - _ .* x --4- - -4 ] X i 1 - ....... -- t ---- --I - - - --, - _ _ _i_ . Forams Stalls - __L. - 1 " Un ____ aarkriz ea Partina v..3100- (..))'1 - --- • • - 4 t t X • - 1. - - - - - --i•- - Van At: cestoOlp Paintrd H3r 3t) P rn r 1 ( A," , ; ak _ --- - - i -4 - - - Van ac c es stile aisle --1 I -,,___ • __ --. ---. - -4 - - - -4 -I _ r - Staridard Hanic ar, spaLe ts lope .,: si x Sta Hdndic 1. slur - - - - Standard Nan& 3p Painted Hand( ), em Neff': (36" +., 36") _ __4. - -..i. 4- - -4-- - - -- - 1 -I ; C2==mININNN...... N NOMMINNOMMENINNENN x -4-- Irvine ramp (cor pty) x x . line ramp landing x x _ _ \Naming groove$ 3t the (top) of in ramp 4 _ Wing Ram p k 3 sides slope) I X _ Vvamin grnove*3 at the (top) or wing rim p I ti3r1GailS x + W)ee'cip (Ramp edge protec ton) -4-- -4 x +- -4,- - - --i------t- - - -- - i --4 i ± - i -4-- - Path of Travel Path ot trawl to purify,: ROW) X X Detec table oarrns to i.ros .tN a venicular pan x -f- hangars i Wheel guide. (Ramp edge protection) ____ 1 - ---4- x i- .- -4- 1 -± - --+ listipheeme Pubbc pay phcne Clear spate in frcnt at phone 1111 h --- Phone cord i ?.9 i Coln sic( (54") III III 1 , , anoi Bike rack x x Newspaper rat k I I In Trash Cars I As h Tr3o/Cigarette Urn x x Planter urrts ortanersitee stamina p;arter.5 -r- -4- 1 ' i -i- robe i i I I I S Sow pat* rocootreh:s . . - -•---- - -4- 111111111.11 at Benz hes • -+------+ - I - , X Ties - - i T x x r ADA title top r X - ; X ,•- .'!-••• . . MIN Seas i i X , Ben: ne i i X , Tae - i T x • AC A Moe tz4: qy‘ ' : -4------ ' . . ---4,- . --- ----4--:- Site Ularbas . . .2 freal• wt.! , , ralr.C e' . . x _ . . . x I Gnaw masreepase c. i , 3: .? -nte• : ec-,:r _ ____.. - ...3 ,x - ; X :- • X ..ar /17.671: '': a ert PC- . • X ,..V.::-.... 3C 'I: ....3.• - X .- 1 .. - - , _ _ ..--i. -1- - _ _____-_. • •-• ---,-- . , Trash Syclosace . ____ .1 r -.. C ' .rf• - -.3 • .4. ___.... .-__ ______ ____ ___ ____ r" - i 1:: , i , .. E r,..re __+_____ X Cc '" • ....._-_ ___. ___ x GENERAL SPECIFICATIONS to. popm,ipl■-■11 1999 Jock in the Box Inc. These drawings and specifications ore the property of Jock in the Box inc and Shall not be copied or reproduced without its previous written consent. RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: 9330 BALBOA AVENUE SAN DIEGO. CA 92123 revisions AMC TYPE: - c t Ez-°• ADORES& Ir - 1.:v 'MLA. IAA •"-• Crt CO rn Co LA CO 11711 SHEET & SITE PLAN TSI.0 oe . 7.406 ■••11mor 111www1 irwe ...kb • - -emr. ...or": Z.'. _ . w Air . et7P SITE PLAN SCOPE OF WORK • i•mor. tro REIM AGE SCOPE OF WORK I • • -.wan an- _ ■■■••• •■■•• ••••110 1 • 1 ■ •••■■ ■■■••••• •r ••■■■■•• ••■••••• •■•• •••11. ■All• •••■••• --.. 1 (E) TRASH ENCLOSURE TO BE POWER WASHED, PREPED AND REPAINTED. (E) PAYPHONE TO BE REMOVED 4 )C t Gk vit/ ' 5 i4 nUOSIAV 01:11 LINE INDICATES LIMIT OF REMODEL WORK THIS PERMIT - 3 - r+ ii i Di CRy %daft MONS MINOR 0 t , Pre OW Ma e ael sel4m# apormi NOM ID mon raj. Appeal of corstrucson clocumis mot VIII w o - =opted cods at sidlulia. MINN approvecl FriC C07/ and =calms admiliesft EIMMO lir dorm dill Ile weft OHIO amps at wet view* Mir Opine I* NINA) 1111110a NOTE Ilemong mph, a am Oa 26.1111 and way Mils anima Ola maw ems r 1 I. 1 11 (E) PATH OF TRAVEL TO PUBLIC R'.0.W.. REMOVE & REPLACE AS REQ'D. PATH OF TRAVEL TO HAVE 5% MAX. SLOPE& 2% MAX. CROSS SLOPE SHALL SLOPE @ 7.5% MAX. NOTE: SEE CONSTRUCTION MANAGER SCOPE OF WORK & TYPICAL DETAIL BOOK FOR ADDITIONAL INFORMATION & DETAILS ON SITE REPAIRS. 1111Panall 1110111.D Car a? %bids CHSION _rarcel • • I 1 I I (E) PATH OF TRAVEL TO BUILDING. REMOVE & REPLACE AS REQ'D. TO PROVIDE LEVEL LANDINGS AT ENTRYS. PATH OF TRAVEL TO! HAVE 2% MAX CROSS SLOPE, RAMP SHALL SLOPE @ 7.5% M 8 EXISTING ACCESSIBLE PARKiN 0 Parcel "C" tio TO BE REMOVED & REPLACED 84! !, RESTRIPED AS REQ'D. PER i lit 1 4: ti i DETAILS ON SHEET A2.0, CROSS i SLOPE NOT TO EXCEED 2%. rcet'.- \'' '. (3. r Parcel "B" ow mos- 4 # tro-ftedruer,s.**NEL-4-s.....m, ELECTRICAL : LSW Engineers 5560 Ruffin Rood, Suite 1 Sir t Dego. CA 92123 Attn. Tony Kroifiger Phone: (858) 268-322 Far (858) 268-1739 I ; fia••••■ way ama. • . I 1■••■•■ oaD GENERAL NOTES 44 1'2400` E 212 2d / NMI I P ••51. • Pk0 - C5°'C' • \ '‘ ,,‘) trn 1 - 1 V.1P . r cr2" \ PA 44 amp f r,1 in PT I ••••••■• ••••lar • ••••■ Mem I e sm. I I MEN I I Inn I I ••••■ I imm e e CONSULTANT INFORMATION OWNER: JACK IN THE BOX ARCHTECTURE DEPARTMENT 9330 Balboa Avenue Soil Diego, CA 92123 Attn. Eric Kerley Phone (858) 57 2558 Fcrc (858) 571-1542 PROJECT DESCRIPTION PROJECT is mAiNTMVNG MANG OCCIPmCv aIRRDIT USE_ EXIS11K Kaput AREA NOT TO BE *nom 91 nEmooti moo UGSVIG COMPumeT coRRIEcTICeas To Apo KN MCI:NOES DM INCLUDED EICSIVIG NES11,0011 FACIUNES ARE CONPUAmT MANG SW AREA, GENERAL CLAN UP MO PAWING. 2. 1€ meta cannicior swat vounr ALL AMIE MOUND APO U1110011a0UND UTILITY LOCATIONS PIM 1 srairin CONSNIuClet TNE COSIAL 0311RACTIN SMALL *TT it SITE 441 131IFY ALL MING COMM MON TO SIMMS BB IZNIENII. COSTIVICTOR WILL OMIT ,ANY/ALI. 0601EPAICIES CONSMUCTION NANKER - OMER^. COreRAVOR SHALL NOTE 'MAT ALL WORK 10 BE OM SUO4 AS IDICAVANONS. 1 CAISSONS, WU& Er-. aoOklED ON ORAUNGS. 6 SNOINg 111NOuT KNOILEDCE OF L� ND OWES ON 116 PL AR STE. lot ANCHITECT AND OMEN ASSUME NO maronsimurf Fon ormamic mom WI. OEM OR HALM as a I NM I I 11111r Parcel dEleat • IL-± -471.--101111-0.-41111/110.1B4. - 0114Eit BONDING ADDRESS: LEGAL JURISDICTION: BUILDING COOE: BUILDING AA: REISODEL AREA-. SEATING,. SEATING AREA& II A ll if>4 r i R. / 2ONSIG OCCUPANCY: TP( OF COISMUCTIOIt slows 1■1•1•N ••••••■• ' -I EXISTING SITE PLAN FOR REFERENCE ONLY NEW WORK SHOWN AS BOLD TEXT SCALE: 1 = 20' EXISTINQ 20 PROPOSER 24 a • Jock in the Box Inc_ 13050 interurban Ave. S. Tukwila, WA 98168 CITY OF TUKWIA. WA 111-4 OUGHT INDUSTRIPO CRIMP B V--N SINGLE Interurban Avenue South 1 8 . 2 I I I I eo I I I I I 3 Seattle City Light R.O.W. al ;I 1 _ z: err r-v s-r-w-emort-reom I I 4/04•=4Sit:st,' rm-mat• LEGAL INFORMATION Li 0 • • S . • NORTH 2003 SC, 2000 UR, 1999 NEC. 2000 UPC & MAC 51-50 REGULATIONS. , EXISTINQ 2.668 SY I PRCPOSED: NONE N/A ID OSTM 1.252 ST DSS 70 PROPOSED: 68 103.0 1.1 KITCHEN ho ( 128 ) A.D.A.A.G. AMERICANS PATH DISABIUTIES ACT ACCESSIBILITY GUIDELINES &P.A. AMERICAN PLY1VOOD ASSOCIATION A. Q. T. ABRASI VE QUARRY 11LE A. S. T. M AMERICAN SOCIETY FOR TESTING MATERIALS ROT. OR (B) BOTTOM C C. B.B. C. T. C. F. C.I . DEG. OR • DIA. OR 0 E. C. F.D. F. R.P. F. S. TSl.0 TITLE SLEET & SITE PLAN TS1 1 INTERIOR SCOPE OF WORK A1.0 EXTERIOR ELEVATIONS & FINISH SCHEDULE A2.0 ACCESSIBILITY REQUIREMENTS ID1.0 FURNITURE AND REFLECTED CEILING PLANS, NOTES ID1.1 FLOORING LAYOUT PLAN AND NOTES AND ENLARGED RESTROOM FLOOR PLAN 1D2.0 INTERIOR ELEVATIONS AND MURALS (MURALS FOR REFERENCE ONLY) INTERIOR DETAILS ID3.1 INTERIOR DETAILS 103.2 INTERIOR DETAILS ID4.0 INTERIOR FINISH SCHEDULE 1D4.1 INTERIOR FINISH SCHEDULE ID4.2 INTERIOR FINISH SCHEDULE E1.0 ELECTRICAL POWER PLAN 1.0 GENERAL SPECIFICATIONS 1.2 GENERAL SPECIFICATIONS s 11246 St GENERAL SPECIFICATIONS - LEGEND & ABBREVIATIONS ROOM NAME ROOM NUMBER BUILDING 8481 MK7CF90 REMODEL 13050 INTERURBAN AVE. S TUKINILA, WA 98168 INTERIOR FINISHES ELEVA11ON/DA11JM MARK EXTERIOR MATERIAL/FINISH EXTERIOR COLOR INTERIOR ELEVATION DETAIL NUMBER SHEET NUMBER CONDUIT CEMEN 11 MOUS BACKER BOARD CERAMIC TILE CONTRACTOR FURNISHED, CON TRACTOR INSTALLED DEGREE DIAMETER ELECTRICAL CON TRACTOR FLOOR DRAIN FIBERGLASS REINFORCED PANEL FLOOR SINK israfts, 590' ; suany Illi . • I I N 4. $ MM. Is Ai ip usait - SUM! SHEET INDEX VICINITY MAP Itos 410 6 7 7 , 1 ARCHITECTURAL INTERIOR DESIGN ELECTRICAL SPECIFICATIOIIS GA. G.B. C.C. GALV. H.D. HOW. INV. JIB OR (JIB.) Jock in the Box Inc. ANGLE it B. MACHINE BOLT MTL. METAL N.T.S. NOT TO SCALE O.C. ON CENTER OWNER FURNISHED, CONTRACTOR INSTALLED OPNG. OPENING P.C. PLUMBING CONTRACTOR PL PLATE Q.T. QUARRY 11LE RAD. OR (R) RADIUS SM SHEET METAL SMS SHEET METAL SCREW STL STEEL STRU CT. STRUCTURAL SUSP. SUSPENDED SW. SYMMETRICAL MK. THICKNESS T & G TONGUE & GROOVE U. B. C. UNIFORM BUILDING CODE U. 0.N. UNLESS OTHERVOISE NOTED VERT. OR (V) VERTICAL V.W.C. VINYL WALLCOVERING ND. %COD W. G. B. WATER RESISTANT GYPSUM BOARD I timb • t1":4 arm. • 41 lb • GAUGE (GAGE) GYPSUM BOARD GENERAL CON TRACTOR GALVANIZED HUB DRAIN HARDWARE HOLLOW METAL INVERTED - \ ■ " • e 111 - 4e1 .11 41. 41111h .-m As 4 111 „el" ... w • .e. . ■ ..- . (TOTAL OF 18 SHEETS) %re. &an 411 leet.t.rrED are 1. • .f. . 1111111 't... •• •.: ' , ..... I 41. Remove ern Remove existing flooring and base to original substrate Remove e� Remove existing flooring and base to original substrate Remove ex Remove existing wall finishes to substrate. Lower to 34' aff Remove knee wall fishes to substrate Instal Marite Wail Panel s - em Save Ice Maine refrigeration Und Compresses Drink stator and related components to be protected Lower cabnt height to 3C aff , Lighting Emergency lights Bug sapper Floors Tile , Floor Drain Clean Outs Drywall FRP Ceiling Ceiling tiles Hard lid . Emergency lights Water closet Paper towel dispenser Mirror Grab bars Soap dispenser Toilet per dispenser Seat cover dispenser Baby changing station Men's RR Finishes Hardware Door jambs Signage FRo Ceding Wes Hard id Alcove max - 24" deep: min 30" wide 1 Access rectangle 30"x Doors Finishes Hardware Door jambs Signage Tile . Floor Drain . Clean Outs Drywall FRP Turning radius minimum 5' Ceding tiles T -Grid Huard id IMES 1111111111111111111111111111 z - �� i;;''t . NOM= X © Remove exist • floorin • and base to on • • substrate Tile -�----MI- X Remove existing wall finishes to substrate. hstall 5/8" Gypsum Walt Board Remove emergency light and replace with Al facture Floor drains not to exceed 2% slope Finishes Hardware Door jambs leg Electrical Building Equipment (enter equipment needed) ltegrount KN Floor • Paint Kit C Install 5/8" water resistant Gypsum Wall Board •11111111111W := mil =man LCN (401114012) or (4041) used hstall 5/8" water resistant Gypsum Wall Board LCN (401114012) a (4041) used Ceiling tiles T -Grid Hard lid tieft an 1111111111111111111111 Will MI AM IIIIV 11111111111111111111111111 Budding trusses, joists, sheathing & roof structure Bearing Walls Stairwell Remove emergency light and replace with Al fixture Shelving Ladder/Roof Hatch .Air Curtain DT ;Air Curtain Back Door .Air Curtain Dining Room . Dishwasher Prep Table Sink Gen Rqmts: OH & Profit. Supervision. Gen :Conditions. Tax Electrical . Service Size .Main Distribution Panel Sub b Panels _ Crrcuiting/Vlfring :Other Electrical JIB 8481 REIMAGE SCOPE OF WORK � 1 1 !Inspected by CONKI ING ul • nU Inter' Prep Vlbrk Remove POS Registers and Monitors from Front Counter 'hstall Air Tight Barrier between Work Area & Kitchen Protect Existing Awnite Front Counter Protect security monitor Protect interior menu and breakfast board Remove protect existing security cameras for reuse leave connected, cover w/plastic and hang from structure Protect existing resin surfaces (trim & chair rail to ;remain) fining Vestibule Pictures Ceiling tiles T -Grid , Hard lid Supply air and return air • lIs Finishes Hardware Door jambs Light fixtures Exit signs Speakers Drywall Wallcovering T -Grid Hard lid Supply air and return air grills , Bug zappers Light fixtures Exit signs Speakers iorefrol t swish* Glazing Decor package Shmice dirt iltir Counter top Knee wall Warc-,=`.errg C eairg ties Hard 0sc SUpoti : and resin : X Tiie Drywa 1 Ceiling T -Grid x Hard li X R emove existing flooring and base to original substrate R emove existing wall finishes to substrate. Comments I JIB 8481 R estrooin Vest. tr; scrl Cty uk.v::a 011105 1 it Ris dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions I :'PIPES x 'zone JePOEZ'_Ei • INTERIOR S.O.W. TS1.1 • 0 INTERIOR SCOPE OF WORK 0 a • • s1 1 : 1 A(4 ) , i 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 1999 Jock in the Box Inc. These drawings and specifications ore the property of Jock in the Box Inc and shall not be copied or reproduced without its previous written consent • EAST ELEVATION S NORTH ELEVATION EQ. SOUTH ELEVATION T1 • GRRO CORATIIE- HIC. PANEL C PANNK 1o' - 1,. 1O' -r 'D CORATII& GRAPHIC. PANEL BETWEEN SHADOW CAST PAN r .' 'T1r.•. T• ...-.+ra,pv. ^.+ EQ. toe S FLOOR PLAN SCALE: 1/4" =1 -0' • ' • ,x ... -. •',T. -•- 3- •vT'-- ffaa"±v"�t'tar_���..-_ e*1+s.- • - - reeve _ r - _ - -' - rm. SCALE: 1 /4 =1' -0 WEST ELEVATION •• . • . •••■44.,1440..- a..•.m - _r..••.••_ •..- .r•- • •- - -- a -..r.. s I. S C A L E : T /4" # 1 ' - 0' cI .....1.11• •• r .--`." -.5.•/•P , . I • • • 4 • }; 1 EXISTING JIB SIGN TO REMAIN NOTES: 1. REPAINT BUILDING AS REQUIRED TO MATCH EXISTING. t i• - I f; 2. NEW GRAPHICS ON NORM. 54011 AND (NEST ELEVATIONS. TO BE PAINTED USING OWNER PROVIDED TEMPLATE. COLOR: JIB RED, SW CUSTOM COLOR. ,AB RED. EXTERIOR ACCENTS LATEX SATIN PRIMARY RED CUSTOM MATCH R3- 10Y63t11 TM COATS. JIB SHADOW RED. FIRST COAT - ,lB RED SECOND COAT - EXTERIOR ACCENTS LATEX SATIN PRIMARY SW 2915 SUN PRIED TOMATO THIRD COAT - JBRED. 3. ALL EXTERIOR GRAPHICS TO RECEIVE GRAFFITI BARRIER. DUMOND CPU 647 GRAFFITI BARRIER COATING. BY DUMOND CHEMICALS. 4. POP STRETCH FRAME OR SHADOW CAST PANELS AS NOTED ON Qfgff....MUJINQQN ELEVATION. PROVIDED BY OW ER, INSTALLED BY G.C. PER OIM€ERS INSTRUC1iONS. 5. SEE FLOOR PLAN FOR NEW EXTERIOR DOORS. f :`JIF.yc,'Y�C•. '- W e :`:rr•_ -�ca .••:• - • ' , .. -'_- -t .. . _-ra. +a�rslaru+na ee• :w.•x - .._.. - - ,eerw.l^*..�r.a,. w -- r�rry- ++rte � � - SCALE: 1 /4" =1' -O" REVIEV:EJFCF oDE com L.La ; li r),1 r. 111 T I c;..l of T L ,K ; ,,, , tia RI III oNo rvvtgr! meco or • rT © 1999 Jock 'm the Box Inc. These drawings and specificoticros ore the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent D rG / J c' AP r`4 r.4 /./ 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z W cc cc „tt 0 ›- ADDRESS: dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions Ilk TYPE: f M . 8 GP j E WIRES site information DRAM BY: SCALE: AS P OTED EXTERIOR ELEVATiONS A1.0 X PG as 0 cr'1 M r. OS 06 M1 MM LA W W r I REIMAGE SCOPE OF WORK le . 8481 1 ittspected by' CONKLING y • • d Q� ,r �� �� P Q � � . ilta ng adet v 'i . . • . ? 1- "1"- ;-; Y .' r•:! + - . - :� . . t - .. i - . .• • Roof/mansard X X Flat roof X X Soffit/pa rapet X X . Roof drains X X ,Wall Surfaces Block X X X WaN Surfaces Stucco X X X _ !Wall Surfaces Wood — X _ X I X ExitslDoors X X X . ;Glass & Glazing _Fascia X X Flyfans X X .Guard poles T X _ X • EAST ELEVATION S NORTH ELEVATION EQ. SOUTH ELEVATION T1 • GRRO CORATIIE- HIC. PANEL C PANNK 1o' - 1,. 1O' -r 'D CORATII& GRAPHIC. PANEL BETWEEN SHADOW CAST PAN r .' 'T1r.•. T• ...-.+ra,pv. ^.+ EQ. toe S FLOOR PLAN SCALE: 1/4" =1 -0' • ' • ,x ... -. •',T. -•- 3- •vT'-- ffaa"±v"�t'tar_���..-_ e*1+s.- • - - reeve _ r - _ - -' - rm. SCALE: 1 /4 =1' -0 WEST ELEVATION •• . • . •••■44.,1440..- a..•.m - _r..••.••_ •..- .r•- • •- - -- a -..r.. s I. S C A L E : T /4" # 1 ' - 0' cI .....1.11• •• r .--`." -.5.•/•P , . I • • • 4 • }; 1 EXISTING JIB SIGN TO REMAIN NOTES: 1. REPAINT BUILDING AS REQUIRED TO MATCH EXISTING. t i• - I f; 2. NEW GRAPHICS ON NORM. 54011 AND (NEST ELEVATIONS. TO BE PAINTED USING OWNER PROVIDED TEMPLATE. COLOR: JIB RED, SW CUSTOM COLOR. ,AB RED. EXTERIOR ACCENTS LATEX SATIN PRIMARY RED CUSTOM MATCH R3- 10Y63t11 TM COATS. JIB SHADOW RED. FIRST COAT - ,lB RED SECOND COAT - EXTERIOR ACCENTS LATEX SATIN PRIMARY SW 2915 SUN PRIED TOMATO THIRD COAT - JBRED. 3. ALL EXTERIOR GRAPHICS TO RECEIVE GRAFFITI BARRIER. DUMOND CPU 647 GRAFFITI BARRIER COATING. BY DUMOND CHEMICALS. 4. POP STRETCH FRAME OR SHADOW CAST PANELS AS NOTED ON Qfgff....MUJINQQN ELEVATION. PROVIDED BY OW ER, INSTALLED BY G.C. PER OIM€ERS INSTRUC1iONS. 5. SEE FLOOR PLAN FOR NEW EXTERIOR DOORS. f :`JIF.yc,'Y�C•. '- W e :`:rr•_ -�ca .••:• - • ' , .. -'_- -t .. . _-ra. +a�rslaru+na ee• :w.•x - .._.. - - ,eerw.l^*..�r.a,. w -- r�rry- ++rte � � - SCALE: 1 /4" =1' -O" REVIEV:EJFCF oDE com L.La ; li r),1 r. 111 T I c;..l of T L ,K ; ,,, , tia RI III oNo rvvtgr! meco or • rT © 1999 Jock 'm the Box Inc. These drawings and specificoticros ore the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent D rG / J c' AP r`4 r.4 /./ 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z W cc cc „tt 0 ›- ADDRESS: dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions Ilk TYPE: f M . 8 GP j E WIRES site information DRAM BY: SCALE: AS P OTED EXTERIOR ELEVATiONS A1.0 X PG as 0 cr'1 M r. OS 06 M1 MM LA W W r I C 1. PARKING 1. PROVIDE ONE (1 ACCESSIBLE PARKING STALL PER TWENTY -FIVE (25) TOTAL PARKING STALLS 2. 8 FT S96? MINIMUM WIDTH OF EACH PARKING SPACE. 3. MINIMUM FT (96 ") (WIDTH) ACCESS AISLE LOCATED ON PASSENGER SIDE. 4. SURFACE OF PARKING SPACE(S) AND ACCESS AISLE SHALL NOT EXCEED 1:50 GRADIENT (2.0%) IN ANY DIRECTION. 5. ACCESSIBLE PARKING SPACE(S1 MUST PERMIT USE OF ALL VEHICLE DOORS. 6. A PARKING BUMPER IS REQUIRED WHEN NO CURB OR BARRIER IS PROVIDED WHICH WILL PREVENT ENCROACHMENT OF CARS OVER THE ADJOINING ACCESSIBLE ROUTE. 7. WHEELCHAIR USERS MUST NOT BE FORCED TO GO BEHIND PARKED CARS OTHER THAN THEIR OWN TO ACCESS AN ADJOINING ACCESSIBLE ROUTE. 8. CURB RAMPS MAY NOT ENCROACH INTO THE REQUIRED DIMENSIONS OF ACCESSIBLE PARKING SPACES OR ADJACENT ACCESS AISLES. 9. ACCESS AISLE MUST CONNECT TO AN ACCESSIBLE PATH Of TRAVEL TO THE FACILITY. PARKING SPACE SIGNAGE EACH PARKING SPACE RESERVED FOR PERSONS WITH DISABILITIES SHALL BE IDENTIFIED BY A REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON DARK BLUE BACKGROUND. 2. SIGNAGE IS INSTALLED AT EACH SPACE. 3. AREA OF EACH SIGN(S) IS NOT SMALLER THAN 70 SQUARE INCHES. 4. WHEN POSTED IN A PATH OF TRAVEL, THE BOTTOM OF THE POLE - MOUNTED SIGN IS 80 MINIMUM FROM THE PARKING SPACE FINISH GRADE. 5. WHEN WALL MOUNTED, SIGN IS CENTERED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE AT A MINIMUM HEIGHT OF 60" FROM THE PARKING SPACE MINIMUM GRADE GROUND OR SIDEWALK. 6. VAN ACCESSIBLE PARKING SPACES HAVE ADDITIONAL SIGN MOUNTED BELOW SYMBOL OF ACCESSIBILITY THAT STATES "VAN ACCESSIBLE ". 7. FOR WASHINGTON STATE, EA. ACCESSIBLE PARKING STALLSIGN SHALL INCLUDE THE INTERNATINAL SYMBOL OF ACCESS AND THE PHRASE "STATE DISABLE PARKING PERMIT REQUIRED ". SITE ENTRANCE SIGNAGE 1. WARNING SIGNAGE REGARDING UNAUTHORIZED USE OF DISABLED PARKING � pES�. SHALL IMMEDIATELY AT EACH ENTRANCE AND VISIBLE FRO�MEEACH PARKING SPACE. PARKING SPACE STRIPING THE SURFACE OF EACH ACCESSIBLE PARKING SPACE OR STALL MUST HAVE A SURFACE IDENTIFICATION DUPLICATING EITHER OF THE FOLLOWING SCHEMES: 1. BY OUTUNING OR PAINTING THE STALL OR SPACE IN BLUE AND OUTLINING ON NE GROUND IN THE STALL OR SPACE IN WIHITE OR SUITABLE CONTRASTING COLOR A PROFILE VIEW DEPICTING A WHEELCHAIR WITH OCCUPANT: BY OUTLINING A PROFILE OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON BLUE BACKGROUND. THE PROFILE SHALL BE LOCATED SO THAT IT IS VISIBLE TO A TRAFFIC ENFORCEMENT OFFICER WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE AND SHALL BE 36" IN LEGTH BY 36" WIDE. BUILT -UP CURB AND CURB -CUT RAMPS GENERAL - ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF IT'S SLOPE EXCEEDS 1 FT (12") OF RISE IN 20 FT (240') OF HORIZONTAL RUN (5% OR GREATER). 1. WI0IH�OFRTHEN LENGTH �IALL�B LEAST �AS�NADE S AS THE CURB RAMP EXCLUDING FUIRES, LEADING TO THE LAN 3. SLOPE OF FANNED OR X FLARED SIDES�(SIDE SLOPES) DOES NOT EXCEED 1 : 10 GRADIENT (10%). 4. CROSS SLOPE DOES NOT EXCEED 1 : 50 GRADIENT 2.OX. 5. FINISHED SURFACE OF RAMP CONTRASTS FROM ADJACENT SIDEWALK, AND IS STABLE, FIRM AND SUP RESISTANT (MEDIUM BROOM FINISH OR EQUIVALENT ). 6. CROSS SLOPE OF LANDING AREA DOES NOT EXCEED 1 : 50 GRADIENT 2.ox . 7. AMP S) DOES NOT PROJECT INTO VEHICULAR TRAFFIC LANES. 8. TRAM 110NS FROM RAMPS TO WAD( GUTTERS OR STREETS ARE FLUSH AND FREE OF ABRUPT CHANGE. 9. A 12" GROOVED BORDER IS PROVIDED ALONG THE TOP AND SIDES OF NE RAMP AT NE LEVEL SURFACE OF THE SIDEWALK (GROOVES APPROXIMATELY 3/4" ON CENTER, 10. CURB RAMP SHALL HAVE DETACTABLE WARNINGS. NNOTEE:C REQUIREMENTS ARE IN ADDITION TO THOSE USTED ABOVE. IF 1. MARKED CROSSINGS THAT ARE RAISED TO THE SAME LEVEL AS THE ADJOINING SIDEWALK SHALL BE PRECEDED BY A 24 INCH DEEP DETACTABLE WARNING COMPLYING WITH SECTION 705 /ICC ANSI 2003, EXTENDING NE FULL WIDTH OF THE MARKED CROSSING. 2. INHERE DETACTABLE WARNINGS ARE PROVIDED ON CURB RAMPS THEY SHALL BE 24 INCHES MINIMUM IN NE DIRECTION OF TRAVEL AND EXTEND THE FULL WIDTH OF THE CURB RAMP OR FLUSH SURFACE. 3. NE DETACTABLE WARNING SHALL BE LOCATED SO THE EDGE NEAREST THE CURB UNE IS 6 INCHES TO 8 INCHES FROM THE CURB UNE. THRESHOLDS 1. fLOOR(SR LANDINGS ARE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE - THRESHOLD OF THE DOORWAY. 4 _ 2. CHANGE IN LEVEL BETWEEN 1/4.. AND 1/2" IS BEVELED AT A GRADIENT OF 1:2. NOTE: A 1/4' MAXIMUM VERTICAL EDGE IS ALLOWABLE AT 3. DOORMATS ARE SECURELY ATTACHED ANCHORED OR RECESSED) AND HAVE A LEVEL LOOP. LEVEL CUT/UNCUT PILE WITH PILE NOT EXCEEDING 1/2" IN HEIGHT. 4. EXPOSED EDGES OF DOORMAT S)ARE FASTENED TO FLOOR SURFACES,..AMD HAVE TRIM ALONG THE EN LENGTH OF THE EXPOSED EDGE. . DOOMS 1. MINIMUM OF 3 FT(36_) IN WIDTH 6' -8" (80 ") IN HEIGHT. 2. OPENS A MINIMUM OF 90 DEGREES. ' 3. CLEAR WIDTH OF THE DOORWAY IS 32" MINIMUM. 4. DOUBLE DOORS 1 AUTOMATIC DOORS - AT LEAST ONE DOOR MUST COMPLY WITH 1, 2 AND 3 ABOVE. 5. ALLLOW DOOR OF DOOR BE HAS OPEENED BY A LCHMIR FOOTREST SURFACE THAT CREATING A TRAP OR HAZARDOUS CONDITION. NOTE: INHERE NARROW FRAME DOORS ARE USED, A 1O- ITCH -HIGH SMOOTH SMOOTH PANEL MUST BE INSTALLED ON THE PUSH SIDE OF THE WHICH 1MLL ALLOW NE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. 6. EFFORT TO OPERATE DOORS IS WITHIN PRESSURES ALLOWED. INTERIOR DOORS - 5 POUNDS MAXIMUM PRESSURE TO OPERATE. EXTERIOR DOORS -&5 POUNDS MAXIMUM PRESSURE TO OPERATE. FIRE DOORS - 15 POUNDS MAXIMUM PRESSURE TO OPERATE 7. TWO DOORS IN A SERIES PROVIDE A MINIMUM OF 48" CLEAR SPACE FROM ANY DOOR P4 ANY POSITION. DOOR HARDWARE 1. EXIT DOORS ARE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY CR ANY SPEOAL KNOWLEDGE OR EFTORT. 2. LATCHING ING AND LC CII*4G DOORS THAT ATE HAND OPERATED ARE OPERABLE PATH A SINGE EFFORT (Dl LEVER T'!PE. PAC BARS OR PUSH-POLL TYPE). 3. OPENING HARDWARE iS CENTERED BETWEEN 30' M4; 44' ABOVE Fes+ F;.00R. 4. DOOR CLOSERS. F PRESENT. MUST BE SE" SO NAT I T TAKES AT LEAS' 3 SECONDS TO CLOSE FROM AN OPEN POST ON CO' '0 DEGREES TO WM TIC 3" OF THE LATC>r± CLEAR SPACE AT DOOM GENERAL - REGARDLESS OF THE 3C AN .CA T SHALL BE A ' JR LANCING Oi4 EACte 90E OF A DOOR t FLOOR OR LAMING ON EAcH 90E OF THE DOOR S LEA, MC ca AR EVE1 AR �OM A N THE DIIRECT O: THE SING :5 A WARM OF 60' it 3 LEVEL AREA JP�'9'E T1{ DIRECTION OF '' DOOR SUNG S A ~AN OF 44' -4a' N ..DOGTH DEFENDING UPON DIRE C TION OF APPROAO9 AND t STENCIL cF ;.ATCN MO CLOSER. 4. SURFACE SLOPE OF THE LEVEL AREA DOES IrOT EXCEED 7 : 50 GRADIENT 5 ativ S1RlcE SIDE CLEARANCE ON PUS SIDE OF DOOR IS PROVIDED A 6. LANDING, LATCH 90E asfausa Ox FkISI4 SLOE OF DOOR IS PROVIDED AI LAN�1G Is IDENTIFICATION SYMBOLS (FOR SANITARY FACILITIES) NOTE: SANITARY FACILITIES ARE REQUIRED 10 PROVIDE TWO SEPARATE TYPES OF SIGNAGE: ONE TYPE LOCATED ON THE DOORWAY OF THE FACILITY, AND ANOTHER TYPE LOCATED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. DOOR MOUNTED SIGNAGE 1. (MEN'S)- EQUILATERAL TRIANGLE 1/4" THICK WITH EDGES 12" LONG AND A RTE POINTING UPWARD. 2. WOMEN''S)- 12' DIAMETER CIRCLE 1/4" THICK. 3 UPER ) IMPOS ED WITM T C RE LE 1/4" " THICK WITH 1/4" THICK TRIANGLE 4. THE CHARACTERS AND BACKGROUND OF THE SIGN IS EGG -SHELL OF THE OR OTHER DR DISTINCTIVELY NON-GLARE FINISH WITH EO THECO LOR AN DC A CONTRAST OF THE DOOR. 5. SIGNS ARE CENTERED ON THE DOOF 60" FROM THE FLOOR. WALL MOUNTED SIGNAGE 1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. THE BORDER DIMENSION OF THIS PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. NOTE: WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. 2. VERBAL DESCRIPTION AS TO RESTROOM USAGE (I.E. MEN'S RESTROOM, ETC.) IS PLACED DIRECTLY BELOW THE: SYMBOL OF ACCESSIBILITY. 3. THE CHARACTERS AND BACKGROUND OF THE SIGN IS EGG-SHELL, MATTE OR OTHER NON -GLARE FINISH AND THE COLOR AND CONAST OF THE SIGN DISTINCTIVELY CONTRAST WITH THE COLOR AND CONTRAST OF THE WALL. NOTE: THE REQUIRED CDLOR OF NE SYMBOL OF ACCESSIBILITY CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. HOWEVER NE APPROPRIATE ENFORCEMENT AGENCY MAY APPROVE SPECIAL t1GNS TO COMPLIMENT DECOR WHEN SUCH SIGNS PROVIDE ADEQUATE DIRECTION TO INDIVIDUALS 'MTH DISABILITIES. 4. SIGNS ARE CENTERED ON THE WALL 60" FROM THE FLOOR. 5. LETTERS AND NUMERALS ARE RAISED 1j32", ARE SANS -SERIF UPPERCASE CHARACTERS AND ARE ACCOMPANIED BY GRADE 2 BRAILLE. CHARACTERS ARE A MINIMUM 5/8" HIGH AND A MAXIMUM OF 2" HIGH. 6. MOUNTING LOCATION ALLOWS A PERSON TO APPROACH WITHIN 3" OF THE SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. SANITATION FACILITIES SINGLE ACCOMMODATION TOILETS 1. ACCESSIBLE UNITS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. 2. EXCEPT AT DOORS, THE MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE IN FACILITY IS 36 ". 3. ENTRY DOOR HAS PRIVACY LATCH (PUSH BUTTON -LEVER RELEASE) 4. SUFFICIENT SPACE FOR WHEELCHAIR MEASURING 30" X 48" TO ENTER ROOM AND PERMIT THE DOOR TO CLOSE IS PROVIDED. 5. A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60" MINUMUM DIAMETER CIRCLE IS PROVIDED WITHIN THE SANITARY FACILITY ROOM. 6. 60" DIAMETER MINIMUM SPACE IS CLEAR OF OBJECTS FROM NE FLOOR TO A HEIGHT OF 27 ". 7. 48" MINIMUM CLEAR SPACE IS PROVIDED IN FRONT OF NE WATER CLOSET. 8. 18" HOLD DIM. BETWEEN CENTER OF WATER CLOSET AND SIDE -WALL CORNER. 9. 28" MINIMUM CLEAR SPACE IS PROVIDED FROM THE WATER CLOSET TO ANY FIXTURE, OR A MINIMUM 32" WIDE CLEAR SPACE TO THE OPPOSITE WALL 10. TOP OF TOILET SEAT IS 17" - 19" FROM FLOOR SURFACE. 11. FLUSH VALVE IS ON WOE SIDE OF TOILET AREA. 12. 5 LB. MAXIMUM FORCE TO OPERATE FLUSH VALVE. 13. WALLS WITHIN COMPARTMENT ARE SMOOTH, HARD AND NON- ABSORBENT TO 48" IN HEIGHT, AND ARE NOT ADVERSELY AFFECTED BY MOISTURE. 14. FLOOR SURFACES OF TOILET ROOM ARE SMOOTH, HARD AND NON- ABSORBENT EXTENDING UPWARD A MINIMUM OF 5" ONTO WALLS. 15. SIDE GRAB BAR IS A MINIMUM OF 42" LONG AND EXTENDS 24" BEYOND THE FRONT OF THE WATER CLOSET. 16. THE FORWARD END OF THE GRAB BAR IS LOCATED A MINI- MUM OF 54" FROM THE BACK WALL. 17. SIDE GRAB BAR BEGINS A MAXIMUM OF 12" FROM THE REAR WALL 18. REAR GRAB BAR IS A MINIMUM 36" LANG. 19. REAR GRAB BAR BEGINS A MAXIMUM OF 6" FROM THE CORNER OF NE WALL ON THE TOILET SIDE. 20. DIAMETER OF GRAB BARS IS 1-1/4" - 1-1/2" OR SHAPE PROVIDES EQUIVALENT GRIPPING SURFACE. 21. CLEARANCE BETWEEN THE GRAB BAR(S) AND WALL IS 1-1/2". 22. GRAB BARS ARE MOUNTED AT 33" TO CENTER OF BAR ABOVE AND PARALLEL TO FLOOR. (FOR TANK TYPE TOILETS, 36" MAY BE ALLOWED F TANK OBSTRUCTS PLACEMENT OF BAR). 23. EDGES OF GRAB BARS ARE SMOOTH WITH A MINIMUM RADIUS OF 1/8 ". 24. MINIMUM STRUCTURAL STRENGTH OF GRAB BAR(S) WILL SUPPORT A 250 LB. POINT LOAD. 25. GRAB BARS DO NOT ROTATE WITHIN THEIR FITTINGS. 26. SURFACE OF WALL ADJACENT TO GRAB BAR(S) IS FREE OF SHARP OR ABRASIVE ELEMENTS. 27. CENTER LINE TOILET PAPER DISPENSER IS LOCATED ON THE WALL WITHIN . 7" MIN. TO 9" MAX. OF THE FRONT EDGE OF THE TOILET SEA 28. 19" MINIMUM HEIGHT FROM FLOOR TO CENTERLINE OF ?SET DISPENSER. (LOCATE BELOW GRAB BAR 1 -1 /2 " M ' 29. TOILET PAPER DISPENSER ALLOWS CONTINUOUS PAPIER KM MIND NOT CONTROL DELIVERY. t, LAVATORIES • 1. MINIMUM 30" X 48" t EAR SPACE 5 PROVIDED IN FRONT OF"1`AYA ORY THAT ALLOWS FORWARD APPROACH. 2. REQUIRED ,CLEAR SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROOTk: ..- OTENDS A: MAXIMUM OF UNDERNEATH THE LAVATORY. . ,. 3. } LAVATORIES ADJACENT TO A SIDE-- HAVE A MINIMUM 187 DISTANCE TO �': CENTER OF FIXTURE. • 4. - 34" MINUMUM .HEIGHT OF RIM OR CDUN.TER ABOVE FINISH FL SURFACE. 5. .29" MINIMUM CLEARANCE FROM BOTTOM Qf APRON TO THE FLOOR. 6. ` KNEE CLEARANCE UNDER FRONT UP IS A 1I NIWUM OF 27' 1001, 30" WIDE, - ;AND EXTENDS A MINIMUM OF 8" IN DE_P1WFROMM THE FRONT OF THE 7. :.TOE CLEARANCE UNDER LAVATORY IS A MINIMUM OF 9' HIGH 30" WIDE, AND VI INM DS A MI I OF 17` IN DEPTH FROM THE FRONT OF THE LAVATORY. 8. AND HOT WATER PIPING IS INSULATED OR CONFIGURED TO PREVENT 9. THERE CONTACT„,- SHARP OR ABRASIVE ELEMENTS UNDER LAVATORY. 10. FAUCETS ARE LEVER TYPE, ELECTRONICALLY ACTIVATED OR APPROVED SELF 11. =SING ARE OPERABLE MTTH SECOND H FLOW). DO NOT REQUIRE TIGHT GRASPING, INCHING OR TWISTING OF THE MIST. 12. 5 LB. MAXIMUM FORCE REQUIRED TO ACTIVATE CONTROLS. URINALS 1. MINIMUM 30" WIDE X 48" DEEP CLEAR ACCESS SPACE AS SF** ON DET. 4/A2.0. (ONE FIXTURE ONLY REQUIRED). 2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR FLOOR SPACE. 3. 17" MAXIMUM RIM HEIGHT ABOVE FLOOR. 4. 44' MAXIMUM HEIGHT OF FLUSH VALVE ABOVE FLOOR. 5. 5 LB. MAXIMUM PRESSURE TO OPERATE FLUSH VALVE. 6. 14' MINIMUM PROJECTION FROM WALL 7. FLOOR SURFACES ARE SMOOTH, HARD AND NON - ABSORBENT EXTENDING UPWARD A MINIMUM OF 5' ONTO WAL _S. 8. WALLS WMTMN 24' OF FRONT AND SIDES OF URINAL ARE SMOOTH, HARD AND NON - ABSORBENT TO 48' 'N HEIGHT, AND ARE NOT ADVERSELY AFFECTED BY MOISTURE. ACCESSORIES IN SANITARY FACILITIES r . MINIMUM 30" X 48" CLEAR FLOOR OR GROUND SPACE IS PROVIDED TO ALLOW FORWARD OR PARALLEL APPROACH T(' ACCESSORIES. 2. ONE FULL U'NOBSTRUCT SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS OR OVERLAPS AN ACCESS= ROUTE OR ADJOINS ANOTHER WHEELOHAIR CLEAR F ;RJR SPACE_ 3. MIRROR( S) IS OUN TEC WON THE BOTTOM OF THE REFLECTIVE SURFACE EDGE NO ►DER 40' FROM THE FLOOR_ 4. OPERABLE PARTS (h�.AyNG COIN SLOTS) Cr ALL FIXTURES OR ACCESSORIES ARE LOCA TED A WAXLI Al OF 40' ielvE FLOOR (I.E SOAP 0iSP'E1r5F.RS. TOOLS. TOILET SEA' "C�fRS AUTO - DRYERS. SANITARY UPON DISPENSERS. WASTE RECEPTACLES. E TZ. )- 5. CONTROLS AND OPERA-IC MECHANISMS ARE OPERABLE WITH ONE HARD MD 00 NOT REQUIRE 1 04T GRASPING, PIMPING, OR Ttl/S,ING OF 1HE VRIST. 6. THE FORCE TO ACTTva COM1S IS 5 L.H. W1 Rl I 6, MSS S AT Flo LEFT ARROW SIGN (USE CHECK BOX ONLY) El MOUNT SIGN TO FACE OF BUILDING PER SIZE PLAN El MOUNT SIGN ON POST � MOUNT SIGN PER DE7A� x- dt003aILDWMa16 'VAN ACCESSIBLE' HANDICAP PARKING SIGN (TYP) PER DET. 10/A2.0 N9TES: 1. PROVIDE (N) OR RELOCATE EXIST'G WHEEL STOP AS REQ'D TO PREVENT ENCROACHMENT OF CAR OVER ADJOINING ACCESSIBLE ROUTE. SEE DET. 16/A2.0 2. SURFACE OF PARKING SPACE AND ACCESS AISLE SHALL NOT EXCEED 1:50 GRADIENT (2.0% IN ANY DIRECTION). INTERNATIONAL SYMBOL OF ACCESSIBILITY STALL EMBLEM PER DET. 10/A2.0 rwc013.O I e SINGLE PARKING SPACE DESIGN LA- 4 Co 0 PER DETAIL 12/A2.0 o 0 HC DIRECTIONAL DOOR (GP1 RIGID x, : -w1104.46 (USE CHECK BOX ONLY) El MOUNT SIGN TO FACE OF BUILDING PER SITE PLAN MOUNT SIGN ON POST PER DETAIL 12/A2.0 HC CROSSING SIGN 1INt A.G.A A.G. CLEARANCE REQUIRED L 1 • 36' N.T.S. i CONCRETE WHEEL STOP 6' 0 0 OF STALL ACCESSIBLE ROUTE z ME C' MOW f 8 FT(96 ")MIN. STALL WIDTH RIGHT ARROW SIGN (USE CHECK BOX ONLY) MOUNT SIGN TO FACE OF BUILDING PER SITE PLAN CONCRETE r rm STOP (*ERE OCCURS 1 1 ff = I s 8 FT(96 ")MIN. AISLE WIDTH MITE REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL WMTH BEADED TEXT OR EQUAL NOTE: SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE AREA OF SIGN TO BE A MIN OF 70 SO. IN. DESIGNATE FOR "VAN ACCESSIBLE" WHERE APPROPRIATE EMBLEM MUST BE LOCATED IN STALL SO THAT IT IS MIST BY A TRAFFIC _ ENFORCEMEN , ?, OFFICER,_ MI1E'N A VEHICLE IS PROPERLY PARKED IN THE ': , SP. (CENTERED AT • 1.�Y =a ENTRANCE TO STALL RIENDEDD r" - 39" MIN. TO 41' MAX. 12" MIN. L • o S± 1/2" RADIUS GREEN 54" MIN. PARKING WARNING SIGN PER DET. 11/S02.0 FACE OF BLDG. CURB g s WQ 42' MIN. REFER TO SITE PLAN SHEET TS1.0 PARKING SPACE SIGNAGE z Iv akni, Ng CHECK eor aid MINING sos post _ '.m V T 90uA10 36" FLUSH VALVE TYPE ACCESSIBLE WATER CLOSET SIGNAGE. PROVIDED & r.1 N BY CONTRACTOR, SEE DETAIL 10/A10 1 3/4' SO. GALv_ STL POST SET M CONC. FOOTING 1 3/4" SO. GALV. S1L POST SET INTO CONC. FILLED BOLLARD r VIDE REFLECTIVE OM TAPE 6' D A CALv. PPE FILLED W/ cow_ PAINT PER OTY STANDARDS Mom PARKING SIGN POST 11111111 AND WITHOUT mum 36" MIN. 24" MIN. RESERVED PARKING rz ewes .ow .a.. imam r- 4- 1 /8" = 1' -O" 1/2" = '. -Os 12" I MMIN. 6" ✓ ' MAX. FRONT VIEW 1/2" = 1 • _0 . CONC. FOa Ng OM NI OILY) n PANNING SIGN POST 1 - 1 IMAM 3,Ar r-d* z WA0005.DWCG124 1 -1/4" MIN. TO 1 -1/2" MAX. NOMINAL DIAMETER T240060Wi l2 1 1877 RESTROOM WALLS ;88 HEIGHT LETTERING 5 I� 10 2" aim 1/3r MIRROR LAVATORIES ACCESSORIES 119201 DOOR YOU N1ED 9GNAGE ' DISPENSER 1883 3803 NO OBJECT CLOSER THAN 1 1/2" TO GRAB BAR FACE OF WALL i DOING WALL IC AO' ACCESSIMUIY 000R DECALS MU MOUNTED SIGNAGE TO BE LOCATED ON LATCH 910E OF DOOR CLEAR OF DOOR MOUNT AT SO' lO �rnotNE OF 91a1 FROM GRID M 11111IILLE UP * CASE ULTRAS DISTRIBUTION AccEssumunr =GNAW SIZE & SPACING OF GRAB BARS RE\ ` 1 Ft'``ED FOR CODE C 3 LIAN., k It '‘v L- OW Of Tu(WI =a Fit ITIMG nI.NITcynni 119371 3804 DRYER 118891 ® (c4 my) 118921 !pail • NTS SEAT SOAP COVER DISPENSER DISPENSER 1/2" = 1 ! PAPER TOIL DtR Nom PIcTOCRAms AND/OR LETTERING ARE NOT REQUIRED ON 000R roUNTEn 90+AGE NTS 3fi = 1•-4r N z MIN. ctEP Svc Fl OR ��O BE WITHIN 14114- h�ets 12' MIN. DOOR CLE REQUIRED WHERE B4'; OSER AND LATCH ARE PR woo x I z I • �coarrw� 6 IAA 0 18" HOLD I X • qty SINGLE ACCOMODATION TOILET 18 6 HOLD MULTIPLE ACCOMODATION TOILET STALL UDE VVEW \ N 36" MIN. { 60' DIA. MIN. 60" MIrJ. FLUSH ACTIVATOR ON MADE SIDE f< 60" MINK. STALL WIDTH S FLUSH ACTIVATOR ON WIDE SIDE 18" MIN. • 3 3 ci f• a a STALL DOOR SHALL NOT SWING INTO THE MINIMUM REQUIRED STALL AREA 1. I . got N • STALL DOOR SHALL BE LOCATED IN THE FRONT PARTITION FARTHEST FROM THE WATER CLOSET. DOOR SHALL BE SELF- CLOSING I a 0 I PLAN VIEW 1/2" = 1' -0" 1/2" = 1 -0" Tir s1' -0 a 1999 Jack n the Box Inc. 9330 BALBOA AVENUE SAN DIEGO, CA 92123 These drawings and specifications are the property of Jack in the Bo. In and shall not be copied or reproduced without its previous written consent Z 0 D DRAWN BY: „1( . J E E NE ' dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions Z s W °' Cro cr kJ v •- x + '0 Q "- its - s U a, QO ,10.‹ ow. a, o ac o0 4 o c en m s= I 7 1j. 7:; U I +: C � N tn e o' ao ao � E EPODE S .r r : ; 2006 site information MI( TYPE J8 f Ir ADDRESS: it • J- ... �.. SCALE: AS SHOW ACCESSIBiLITY REQUIREMENTS WAC51. 6o A2.0 - inii • . in .. , ..-: g q.2 • &t �;: r iii Iii ? .,..., f 1 I ' .` yi; �l A \ ~ [ . • �•A .....,-K7 .. , '....'. A.• . - at 1 illEffilligliti , i • .' ?( ".' Wi 4 L Wall- Mounted Flat Screen Monitor(s) • Contractor shall provide and install a duplex "clock outlet" behind each woll- mounted flot screen monitor with a dedicated 120V, 20A circuit, fed from a 20A breaker (3 # 12 AWG in )1" conduit). Install clock outlet at centerlines of flat screen monitor(s). All flot screen monitors (up to 9) con be served by the same dedicated circuit. • Contractor sholl provide and install a 2" PVC conduit from 6" above the ceiling down to 2" above the centerline of the clock outlet and 5" to the right of the clock outlet. Provide and Install a double gong mud ring on the centerline of the 2' PVC conduit (vertically) and the centerline of the clock outlet (horizontally). • The wall - mounted flat screen monitor will be provided and Installed by others. The installer will also be responsible for the running of the communication cable and all final connections. FURNITURE PLAN NOTES 3. ALL TABLE TOPS SHALL BE ATTACHED TO BASE PER MANUFACTURER'S INSTRUCTIONS. 8. SEE DETAIL SHEETS FOR BLOCKING AT COUNTER TOPS �.a..�.�..A,.. -�..,.-. -..► •-...- .. ! .. - -.. ...11.11. 1 _. •._. -" r 1. ALL DIMENSIONS ARE TO FACE OF FINISHED DRYWALL AND ARE CONSIDERED CRITICAL UNO. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH SHOP DRAWINGS AND PLANS AGAINST REQUIRED CLEARANCES. 2. REFER TO INTERIOR DETAILS AND FINISH SCHEDULE FOR MORE INFORMATION. 4. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL QUANTITIES BEFORE ORDERING AND INSTALLING MATERIAL 5. ALL EXPOSED FINISH CORNERS AND SEAMS REQUIRE CAULKING. IN ADDITION, BUT NOT LIMITED TO ALL FIXED EQUIPMENT, ALL AVONITE SEAMS, BACKSPLASH AT BAR TOP. ETC. DO NOT APPLY CAULKING TO ANY VWC SURFACE. 6. GENERAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL, MECHANICAL AND PLUMBING WITH NEW INSTALLED EQUIPMENT. 7. FINAL SEATING LAYOUT SHALL COMPLY MATH THE LATEST EDITION OF THE AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDEUNES (A.D.A.A.G.) AND ALL LOCAL CODES AND ORDINANCES. Sal` -Save Kiosk at the Front Counter EMPLOYEE ROOM fT _ - 1 • L J INSTALL NEW OUTLET FOR idUSIC SYSTEM. SEE ELECT. DINGS. FOR ADO'L WO. (C.F. C.I. ) I r 1 f • O -H 2' -6" f 3'- O MEN'S (MCC HT- d' -O" ( 9. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT ANY SPECIAL KNOWLEDGE OR EFFORT OR THE USE OF A KEY. ALL INTERIOR DOORS SHALL BE LABELED "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED ". PER I.B.C. 1 0. POST OCCUPANCY LOAD SIGN (JIBg1889) IN CONSPICUOUS PLACE NEAR MAIN EXITS AT 6' -10" A.F.F. PER I.B.C. SECT. 1007.2.6. PROVIDE TOP & BOTTOM AND CAULK AROUND ALL SIDES. SIGN TO READ: "MAXIMUM SEATING CAPACITY - 67 SEATS ". EQ. 1 a if 4i VYOKSTdT10N 11. ALL FINISH SURFACES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF CLASS III OR HIGHER (FLAME SPREAD INDEX 76 THROUGH 200 & A SMOKE DENSITY RATING OF 450). 12. ALL DRAPES, CURTAINS & DECORATIVE MATERIAL PROVIDED AND /OR INSTALLED BY THE GENERAL CONTRACTOR SHALL BE MADE FROM NONFLAMMABLE MATERIALS OR TREATED WITH FLAME RETARDANT AS APPROVED BY THE LOCAL FIRE MARSHAL 13. ANY TIME THE BUILDING IS OCCUPIED, THE MEANS OF EGRESS SHALL BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOT- CANDLE AT NE FLOOR LEVEL. PER I.B.C. 14. PROVIDE EXIT SIGNS FOR EGRESS IDENTIFICATION PER I.B.C. 15. PROVIDE APPROVED EGRESS ILLUMINATION AND ILLUMINATED EXIT SIGNS PER I.B.C. " 1111111-11 F 1< It- - ____) MEN'S 14 r ! •••••• - ,p....- +►._ _ _ �..�.. .� °: tom : ■•■ 7 �.... ,...��.�... �.�".,-- .-.... .. 3' -10' .�i Cortractor seal provide and install a duplex receptacle on the `service side of the par y w below the front service counter .Id+ a dedicated "20V. 20A circuit, fed from a 20A breaker (3 9 12 ANG n r conduit). Instate receptacle at 28" AFT and tiredly bet:ind the self -save Kiosk or cs drected by the construction mvnoger • The self -serve kiosk wile be provided and installed by others. The ins«ier .i also be r ponsale for the running of the car - erlU rieotron calb+e avid all final comedians. • Contractor shall provide and install a duplex receptacle in the low alvidr; .eM .Fitt+ a dedicated 120V. 20A c arit fled frorn a 20A breaker (3 # ;2 *w; r y4 .sotN ► : =:; instal receptacle at 1 A' AFT and (*redly behind to* setf -serve kiosk or as (fretted by the cc r's`. uctice r onOger a : tractor shoo provide ar+C instal 4' . 4` : cow and 1' oo"dit •din pui .ire ct t8 AFT and 5 to the rit of tl+e _ duvet receptacle. ur w Run conougt do_ drvid mil. . under floor. them up to underside of front counter counter an 'service ode at .9' Aft Scwcut floor cr.! as 'enured for the installation of the conduit, paten =rd repair to mta wasting. • The self -serve kiosk ad be provided and totalled by others. The irstaker ea also be rlpormie for the running of the cornrnurucobari calm and all final connections. 1' -10' I I II I 11 �; ifil'ORICSTATRAIJ - - VEST 1 1 f5' -10' (EPA 1=:1 4 ==41- 11 / 4 WOMEN'S+ 1 I • • 1 PER 9,b SOME 10 (E SERVICE E'CSTNG KITCHEN AREA TO REMAIN UNCHANGED. t r 13 • = - -• _ - -- = - - -�/ .J■ • I , • r- - EQ. } U DINING .�_ LAW WILL Pu grt Id e REFLECTED CEILING PLAN I ---- - - - - -- �D • r CEILING ABOVE DRINK STATION SHALL BE A SMOOTH WASHABLE SURFACE, SEE INT. FIN. SCH. • • r . 5 -9' FURNITURE DIMENSION PLAN TAP. r ±9' a vir Fr) I tae Oi 1 . GENERAL CONTRACTOR TO PROVIDE HEALTH DEPARTMENT APPROVED TEMPORARY RESTROOMS FOR USE BY JIB EMPLOYEES THROUGHOUT DURATION OF PROJECT. • ALL DEMOLITION WORK SHALL BE COORDINATED MATH THE ENTIRE SET OF CONSTRUCTION DOCUMENTS TO DETERMINE EXTENT OF SITE AND BUILDING DEMOUTION. • GENERAL CONTRACTOR TO PROTECT AND STORE ALL IDENTIFIED EXISTING ITEMS THAT ARE TO BE REUSED/RE- INSTALLED. 5. REFER TO INTERIOR DETAILS AND INTERIOR FINISH SCHEDULE FOR MORE INFORMATION. GENERAL NOTES GENERAL CONTRACTOR TO INSTALL AIR TIGHT BARRIER BETWEEN WORK AREA AND FOOD AREAS. Bing Huns Flat Screen Monitor(s) • Contractor shall provide and install a duplex receptacle within 6" of the support pole for the ceiling hung flat screen monitor. The electrical circuiting is the some as that for the wall mounted flat screen monitor • The cuing - hung flat screen monitor will be provided and installed by others. The instiller will also be responsble for the running of the communication cable and all final connections. NOTE: "EQ12 (RED TRACK) WILL NOT BE PHYSICALLY ATTACHED TO TYPE 'C' FIXTURES AT THIS LOCATION. TRACK SHOULD BE RUN IN CLOSE PROXIMITY TO THE FIXTURE, BUT WILL NOT ATTACH' CEILING PLAN NOTES 1. INSTALL ACOUSTIC CEILING TILE (ACT) PER MANUFACTURER'S INSTRUCTIONS. SEE DETAILS FOR MORE INFORMATION. 2. ALL UGHT FIXTURES SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. PENDANTS SHALL BE CENTERED ON TABLE UNO. IN GENERAL, FIXTURES SHALL BE ALIGNED AND LOCATED AS SHOWN HEREIN. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. 3. REFER TO DETAILS AND INTERIOR / EXTERIOR ELEVATIONS FOR MORE INFORMATION AND LOCATIONS. 4. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBIUTY TO VERIFY ALL QUANTITIES BEFORE ORDERING AND INSTALLING MATERIAL 5. NOT USED 6. ALL GRILLES, FIXTURE TRIM, SPEAKERS AND UNITS LOCATED IN CEIUNG SHALL BE FINISHED TO MATCH THE ADJACENT CEIUNG FINISH COLOR. 7. DIMENSIONS ARE FROM FINISH FLOOR AND / OR FINISHED DRYWALL 8. LATERAL FORCE BRACING FOR SUSPENDED ACOUSTIC TILE CEIUNG: LEGEND A. PROVIDE (4) f12 GAUGE WIRES SECURED TO MAIN RUNNER WITHIN 2' OF CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT ANGLE NOT TO EXCEED 45 DEGREES FROM PLANE OF CEIUNG. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12' -O" O.C. IN BOTH DIRECTIONS WITH FIRST POINT WITHIN 4' -0' OF EACH WALL PROVIDE SOUD ATTACHMENT OF THE RESTRAINT WIRES TO STRUCTURE ABOVE. B. INSTALL COMPRESSION STRUT TO THE MAIN RUNNER AND EXTEND TO AND FASTEN TO STRUCTURE ABOVE AT 12' -0" O.C. EACH DIRECTION OR EVERY 144 S.F. OF CEIUNG AREA PER U.B.C. SIDS. 25-2. PENDANT LAMP MOUNTING HEIGHTS 1. 2. 3. PENDANT ABOVE BAR TOP LOCATED AT 6' -O" A.F.F. PENDANT ABOVE ROUND TABLE TOP LOCATED AT 6'- O'A.F.F. PENDANT ABOVE LOW TABLE TOP LOCATED AT 5- O'A.F.F C. D. CORE DRILLED TABLE P. L PENDANT LIGHT FIXTURE EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED gall PEW CONSTRUCTION ( CB 4 0 MOISTURE RESISTANT REGIONS PROVDE THE FOu.0WING MOISTURE RESISTANT MATES. SEE SPECIFICATIONS FOR OTHER DETAILS 1_ DINS S MNd .IE lit FACED INSULATION AT EXTERIOR STUD WALLS N lEU OF KRAFT FACED INSULATION_ 2_ t O QA PACIFIC D NSARYOR PLUS INTERIOR FMiEGUARD TYPE X GLASS MAT GYPSUM BOARD 14 I.IEJ GL PAPER FACED GYPSUM BOARD. .3. INSTALL LIVE MILL COWERING NTH 2INSSER PLUS a= NC NUM PROS COMM& Mu. mem SYS1EIL TO COATS OF S7I MI PLUS MEW MULL A VIAll. COWING WIN SURE-COMP IDENTIFIES NEW DECOR ITEM OR FINISH. SEE INTERIOR FINISH SCHEDULE, SHEET 04.0 FOR CONTRACTOR SCOPE INDICATES DOOR PER SCHEDULE NON-ENERGIZED r te' DECORATIVE TRACK PER SCH ED. 1 CnnP rDMPLIANcE I ry .f E r. ErL./ r JP t -I / 11 ' Ct./ Of T uk.vila Pi m - 'iT'c ir r ?C7f A I " CIP ANNUM P"L 0 I • .:,,A6.T+ivertiA 9330 BALBOA AVENUE SAN DIEGO, CA 92123 0 1999 Jade in the Box Inc. These drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. RELEASE: P.M.(JB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions M w. a1 a1 0 rn �i r\ In In �o I EalletE s 08/.2/2006 I site information MK TYPE: = ? JI B # i p :.- ADDRESS: - v 2 I^ p - .. . 1- K ' ... r. Q DRAIN BY: , 06. : - LE SCALE: 1/4' = 1'-0' FURNITURE II RCP PLANS, NOTES & SOW L IDI.O r f f • ;r • r L INSTALL (N) PARTITION PER FINISH SEE DETAIL 2/03.1 R _ • ■••••••••••••-••■■r K - mss .••••• w. r- •••••• - ► • • 59' MIN. ' (E) WATER CLOSET TO REMAIN SEES SHT. A2.0 ter REMOVE & RELOCATE (E) WATEi CLOSET (O.F.C.I.) SEE SHT. A2.0 FOR ADD'L INFO. REMOVE & REPLACE (E) STUD WALL FOR TOP AC BOTTOM CONN. SEE DETAILS, TYP. FOR ADD'L ;INFO. MEWS / 32' M IN. i i 1 3 . -0 . MIN. 4' MAX. U L 6 3/4 (E) �CAA ,VA I t 10 BE LOCATED 4' -4 1/4' ROOD* (E) ' -c :.R SEE 94T. A2.0 a CI ,;. 1W. fir= EMIM I � I / I / I ,' r -3' � i i Ili I w 1 ...J i (E) URINAL TO M*N. ENLARGED RESTROOM FLOOR PLAN INSTALL (N) PARTITION PER FINISH SCHEDULE, SEE DETAIL 2/103.1 REMOVE (E) WALL & DOOR 5' -0' (E) LAVATORY TO • i 1/2." - ,`-0r d9IE� 1) SEE SHT. A2.0 FOR ADD'L INFO. 2) G.C. TO RELOCATE SEWER ROUGH -IN, AS REVD., TO INSURE PROPER CLEARANCE TO PLUMBING FIXTURES. 3) G.C. TO INSTALL (N) CROME STANDOFFS, AS REQ'D., ON PLUMBING FIXTURES. i _ 'VESTIBULE • (E) WATER CLOSET TO REMAIN SEE SHT. A2.0 FOR ADO'L. WO. P } I O /EWING grafr4 MCA 10 REMAIN uNcHwICEn. SERVICE FLOORING GENERAL PLAN NOTES 1. INSTALL FLOORING AS PER MANUFACTURER'S INSTRUCTIONS. SEE DETAIL SHEETS FOR MORE INFORMATION ON TRANSITIONS AND BASE CONDITIONS. 2. FLOORING SHALL BE INSTALLED AS THERE IS NO POOLING OF UQUID. ANY SUCH CONDITIONS SHALL NOT BE ACCEPTED BY THE OWNER AND CORRECTION WILL BE REQUIRED. 3. REFER TO INTERIOR FINISH SCHEDULE FOR MORE INFORMATION. 4. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL QUANTITIES BEFORE ORDERING OR INSTALLING FLOORING MATERIAL. 5. ALL GROUT SHALL BE SEALED. 6. NOT USED. 7. REFER TO FLOORING LAYOUT AND FINISH SCHEDULE FOR SANITARY COVE BASE COLOR. 8. CONTRACTOR SHALL ORDER AND INSTALL FLOORING MATERIAL IN MANNER AS SHOWN HERE IN. 9. A MINIMUM 1% STOCK OF ALL TILE SIZES AND COLORS SHALL BE CONSIDERED ATTIC STOCK AND LEFT FOR OWNER AT UNIT LOCATION. 10. IT IS RESPONSIBILITY OF CONTRACTOR TO VALIDATE FLOOR TILE SQUARE FOOTAGE PRIOR TO ORDER MATERIAL. ! 1_1 I I I I Ii I I ii I I I .1 I ' I I __ I _ i I Li miti i am I tKa L j i I 111LE BASE AT prQ STAIN 94A\l BE C (N) owwsious s/ec' RADIUS uE COW ate. 21 Mt RN. soy Ti = 924 SQ.FT. T2 = 221 SQ.FT. T3 = 218 SQ.FT. (INCL 10X WASTE - SEE NOTE 10/ID1.1) PARTIAL FLOOR LAYOUT & FINISHES i 1 REV/EVJED FOR i CODE COMP; TAN 1 � 1 /4 ' = 1'-o MAY 3 0 200e City OfTtik - t; : 3 JfLU tw 9ftifiWiki r- to P1109 °will) Oft or susisu Wa• rq fCr' 'i�.`Gl © 1999 Jock in the Box Inc. These drawings and specifications are the property of Jock in the Box Inc and shall not be copied or reproduced without its previous written consent RELEASE: P.M.(JB ONLY): PERMIT: APR. 17, 2006 BID: CONS1RUCT1ON: 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z W cc I HESS: dates revisions C i MK TYPE: rA CUM DE PActT 1 fi v C a C0 01 c+ g 4r I trimEs JE 2 site information i► �?- - r L • ia AS MORD X M a' 00 et; r, v1 cc Co C ORAL! BY: _ FLOORING LAYOUT PLAN&ITES a ENL RR PLAN ID1.1 4 PL1 1 1880 1877 • M INTERIOR ELEVATION • ce 0 W 1881 INTERIOR ELEVATION INTERIOR ELEVATION 0 1 d u7 NTERIOR ELEVATION NTERIOR ELEVATION Nie ( v13) It: v► t: INTERIOR ELEVATION 11 110111131 • S VAC11 1246 FOR SANITARY COVE! FLOOR PLAN AND FIH INTERIOR ELEVATION INTERIOR ELEVATION FOR SIGN & DIB ION MASERS SEE OCT. �i e 'FOR TILE BASE FINISH REFER TO FLOOR PLAN AND FINISH SCHEDULE - TYPICAL OWNIC 3' -6' BASE FINISrI REFER TO SCHEDULE - TYPICAL i f • : FOR S TAR`i , rE 'ME BASE F HSH REFER TO ROOK PLAN ANC =ISSN SC?EIV-E - TYPICAL WPM NIL INTERIOR ELEVATION INTERIOR ELEVATION • NOTCH APRON AT BRACKETS, TYP. c S N INTERIOR ELEVATION e 1920 1921 INTERIOR ELEVATION ✓ L IAI S T VOIV3 INTERIOR ELEVATION IL NTERIOR ELEVATION r IMO PAIL V111203 \ —cr) l.. INTERIOR ELEVATION NOTE: FOR DISTRIBUTION NUMBERS & FOR RONSTAEIATION lFORMAT10N- REFER TO SHT A2-0 DETAILS • . INTERIOR ELEVATION INTERIOR ELEVATION - 4 u : 'AW FOR TILE BASE FINISH REFER TO FLOOR PLAN AND FINISH SCHEDULE - TYPICAL FQR I CODE CC7'%1PLIAfi :E p'9ir.rs — •r ,h .( c. C T_ c ..�, ; ;.j K'•': III ;I: Ip n'R I)T" "Tgr'l P610(414 » Io nrt a 1999 Jade in the Box Inc. These drawings and specifications Ore the property of Jock in the Box Inc and shall not be copied or reproduced without its previous written consent. /fH4 .(6r0 J�J ( _,f PAR 'ME 1`4 , 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z 0 >— J 1 ADORES& dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions Z .- k. 431 W el t 1 I o < r71 X Cr r3 V 471 . t o v ipp 'Q • ' o+ v, a l /3 g 00 00 > III° CI 0 u�iv co co • v Io in 1n C in r /� Cs a� :1 v+ CO CO E'er ae •..'MOs site information �\ TYPE: - J it :C Ir • _ I r Y sc 1/4• =1'-0" INTERIOR ELEVATiONS is MURALS ID2.0 ORAW4 BY: JEF .* • - 1 rianun LIC . La As . ......_ ....._ _ .. .. _____ -4 -4- . - -4 _ _ P _ --i i' - 4 t - st -4-4 . t.. .. . • X cm,- r,-.0 313tylm/ ) Cul Us - --+ - --• - _____ - _ .* x --4- - -4 ] X i 1 - ....... -- t ---- --I - - - --, - _ _ _i_ . Forams Stalls - __L. - 1 " Un ____ aarkriz ea Partina v..3100- (..))'1 - --- • • - 4 t t X • - 1. - - - - - --i•- - Van At: cestoOlp Paintrd H3r 3t) P rn r 1 ( A," , ; ak _ --- - - i -4 - - - Van ac c es stile aisle --1 I -,,___ • __ --. ---. - -4 - - - -4 -I _ r - Staridard Hanic ar, spaLe ts lope .,: si x Sta Hdndic 1. slur - - - - Standard Nan& 3p Painted Hand( ), em Neff': (36" +., 36") _ __4. - -..i. 4- - -4-- - - -- - 1 -I ; C2==mININNN...... N NOMMINNOMMENINNENN x -4-- Irvine ramp (cor pty) x x . line ramp landing x x _ _ \Naming groove$ 3t the (top) of in ramp 4 _ Wing Ram p k 3 sides slope) I X _ Vvamin grnove*3 at the (top) or wing rim p I ti3r1GailS x + W)ee'cip (Ramp edge protec ton) -4-- -4 x +- -4,- - - --i------t- - - -- - i --4 i ± - i -4-- - Path of Travel Path ot trawl to purify,: ROW) X X Detec table oarrns to i.ros .tN a venicular pan x -f- hangars i Wheel guide. (Ramp edge protection) ____ 1 - ---4- x i- .- -4- 1 -± - --+ listipheeme Pubbc pay phcne Clear spate in frcnt at phone 1111 h --- Phone cord i ?.9 i Coln sic( (54") III III 1 , , anoi Bike rack x x Newspaper rat k I I In Trash Cars I As h Tr3o/Cigarette Urn x x Planter urrts ortanersitee stamina p;arter.5 -r- -4- 1 ' i -i- robe i i I I I S Sow pat* rocootreh:s . . - -•---- - -4- 111111111.11 at Benz hes • -+------+ - I - , X Ties - - i T x x r ADA title top r X - ; X ,•- .'!-••• . . MIN Seas i i X , Ben: ne i i X , Tae - i T x • AC A Moe tz4: qy‘ ' : -4------ ' . . ---4,- . --- ----4--:- Site Ularbas . . .2 freal• wt.! , , ralr.C e' . . x _ . . . x I Gnaw masreepase c. i , 3: .? -nte• : ec-,:r _ ____.. - ...3 ,x - ; X :- • X ..ar /17.671: '': a ert PC- . • X ,..V.::-.... 3C 'I: ....3.• - X .- 1 .. - - , _ _ ..--i. -1- - _ _____-_. • •-• ---,-- . , Trash Syclosace . ____ .1 r -.. C ' .rf• - -.3 • .4. ___.... .-__ ______ ____ ___ ____ r" - i 1:: , i , .. E r,..re __+_____ X Cc '" • ....._-_ ___. ___ x GENERAL SPECIFICATIONS to. popm,ipl■-■11 1999 Jock in the Box Inc. These drawings and specifications ore the property of Jock in the Box inc and Shall not be copied or reproduced without its previous written consent. RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: 9330 BALBOA AVENUE SAN DIEGO. CA 92123 revisions AMC TYPE: - c t Ez-°• ADORES& Ir - 1.:v 'MLA. IAA •"-• Crt CO rn Co LA CO 11711 SHEET & SITE PLAN TSI.0 oe . 7.406 ■••11mor 111www1 irwe ...kb • - -emr. ...or": Z.'. _ . w Air . et7P SITE PLAN SCOPE OF WORK • i•mor. tro REIM AGE SCOPE OF WORK I • • -.wan an- _ ■■■••• •■■•• ••••110 1 • 1 ■ •••■■ ■■■••••• •r ••■■■■•• ••■••••• •■•• •••11. ■All• •••■••• --.. 1 (E) TRASH ENCLOSURE TO BE POWER WASHED, PREPED AND REPAINTED. (E) PAYPHONE TO BE REMOVED 4 )C t Gk vit/ ' 5 i4 nUOSIAV 01:11 LINE INDICATES LIMIT OF REMODEL WORK THIS PERMIT - 3 - r+ ii i Di CRy %daft MONS MINOR 0 t , Pre OW Ma e ael sel4m# apormi NOM ID mon raj. Appeal of corstrucson clocumis mot VIII w o - =opted cods at sidlulia. MINN approvecl FriC C07/ and =calms admiliesft EIMMO lir dorm dill Ile weft OHIO amps at wet view* Mir Opine I* NINA) 1111110a NOTE Ilemong mph, a am Oa 26.1111 and way Mils anima Ola maw ems r 1 I. 1 11 (E) PATH OF TRAVEL TO PUBLIC R'.0.W.. REMOVE & REPLACE AS REQ'D. PATH OF TRAVEL TO HAVE 5% MAX. SLOPE& 2% MAX. CROSS SLOPE SHALL SLOPE @ 7.5% MAX. NOTE: SEE CONSTRUCTION MANAGER SCOPE OF WORK & TYPICAL DETAIL BOOK FOR ADDITIONAL INFORMATION & DETAILS ON SITE REPAIRS. 1111Panall 1110111.D Car a? %bids CHSION _rarcel • • I 1 I I (E) PATH OF TRAVEL TO BUILDING. REMOVE & REPLACE AS REQ'D. TO PROVIDE LEVEL LANDINGS AT ENTRYS. PATH OF TRAVEL TO! HAVE 2% MAX CROSS SLOPE, RAMP SHALL SLOPE @ 7.5% M 8 EXISTING ACCESSIBLE PARKiN 0 Parcel "C" tio TO BE REMOVED & REPLACED 84! !, RESTRIPED AS REQ'D. PER i lit 1 4: ti i DETAILS ON SHEET A2.0, CROSS i SLOPE NOT TO EXCEED 2%. rcet'.- \'' '. (3. r Parcel "B" ow mos- 4 # tro-ftedruer,s.**NEL-4-s.....m, ELECTRICAL : LSW Engineers 5560 Ruffin Rood, Suite 1 Sir t Dego. CA 92123 Attn. Tony Kroifiger Phone: (858) 268-322 Far (858) 268-1739 I ; fia••••■ way ama. • . I 1■••■•■ oaD GENERAL NOTES 44 1'2400` E 212 2d / NMI I P ••51. • Pk0 - C5°'C' • \ '‘ ,,‘) trn 1 - 1 V.1P . r cr2" \ PA 44 amp f r,1 in PT I ••••••■• ••••lar • ••••■ Mem I e sm. I I MEN I I Inn I I ••••■ I imm e e CONSULTANT INFORMATION OWNER: JACK IN THE BOX ARCHTECTURE DEPARTMENT 9330 Balboa Avenue Soil Diego, CA 92123 Attn. Eric Kerley Phone (858) 57 2558 Fcrc (858) 571-1542 PROJECT DESCRIPTION PROJECT is mAiNTMVNG MANG OCCIPmCv aIRRDIT USE_ EXIS11K Kaput AREA NOT TO BE *nom 91 nEmooti moo UGSVIG COMPumeT coRRIEcTICeas To Apo KN MCI:NOES DM INCLUDED EICSIVIG NES11,0011 FACIUNES ARE CONPUAmT MANG SW AREA, GENERAL CLAN UP MO PAWING. 2. 1€ meta cannicior swat vounr ALL AMIE MOUND APO U1110011a0UND UTILITY LOCATIONS PIM 1 srairin CONSNIuClet TNE COSIAL 0311RACTIN SMALL *TT it SITE 441 131IFY ALL MING COMM MON TO SIMMS BB IZNIENII. COSTIVICTOR WILL OMIT ,ANY/ALI. 0601EPAICIES CONSMUCTION NANKER - OMER^. COreRAVOR SHALL NOTE 'MAT ALL WORK 10 BE OM SUO4 AS IDICAVANONS. 1 CAISSONS, WU& Er-. aoOklED ON ORAUNGS. 6 SNOINg 111NOuT KNOILEDCE OF L� ND OWES ON 116 PL AR STE. lot ANCHITECT AND OMEN ASSUME NO maronsimurf Fon ormamic mom WI. OEM OR HALM as a I NM I I 11111r Parcel dEleat • IL-± -471.--101111-0.-41111/110.1B4. - 0114Eit BONDING ADDRESS: LEGAL JURISDICTION: BUILDING COOE: BUILDING AA: REISODEL AREA-. SEATING,. SEATING AREA& II A ll if>4 r i R. / 2ONSIG OCCUPANCY: TP( OF COISMUCTIOIt slows 1■1•1•N ••••••■• ' -I EXISTING SITE PLAN FOR REFERENCE ONLY NEW WORK SHOWN AS BOLD TEXT SCALE: 1 = 20' EXISTINQ 20 PROPOSER 24 a • Jock in the Box Inc_ 13050 interurban Ave. S. Tukwila, WA 98168 CITY OF TUKWIA. WA 111-4 OUGHT INDUSTRIPO CRIMP B V--N SINGLE Interurban Avenue South 1 8 . 2 I I I I eo I I I I I 3 Seattle City Light R.O.W. al ;I 1 _ z: err r-v s-r-w-emort-reom I I 4/04•=4Sit:st,' rm-mat• LEGAL INFORMATION Li 0 • • S . • NORTH 2003 SC, 2000 UR, 1999 NEC. 2000 UPC & MAC 51-50 REGULATIONS. , EXISTINQ 2.668 SY I PRCPOSED: NONE N/A ID OSTM 1.252 ST DSS 70 PROPOSED: 68 103.0 1.1 KITCHEN ho ( 128 ) A.D.A.A.G. AMERICANS PATH DISABIUTIES ACT ACCESSIBILITY GUIDELINES &P.A. AMERICAN PLY1VOOD ASSOCIATION A. Q. T. ABRASI VE QUARRY 11LE A. S. T. M AMERICAN SOCIETY FOR TESTING MATERIALS ROT. OR (B) BOTTOM C C. B.B. C. T. C. F. C.I . DEG. OR • DIA. OR 0 E. C. F.D. F. R.P. F. S. TSl.0 TITLE SLEET & SITE PLAN TS1 1 INTERIOR SCOPE OF WORK A1.0 EXTERIOR ELEVATIONS & FINISH SCHEDULE A2.0 ACCESSIBILITY REQUIREMENTS ID1.0 FURNITURE AND REFLECTED CEILING PLANS, NOTES ID1.1 FLOORING LAYOUT PLAN AND NOTES AND ENLARGED RESTROOM FLOOR PLAN 1D2.0 INTERIOR ELEVATIONS AND MURALS (MURALS FOR REFERENCE ONLY) INTERIOR DETAILS ID3.1 INTERIOR DETAILS 103.2 INTERIOR DETAILS ID4.0 INTERIOR FINISH SCHEDULE 1D4.1 INTERIOR FINISH SCHEDULE ID4.2 INTERIOR FINISH SCHEDULE E1.0 ELECTRICAL POWER PLAN 1.0 GENERAL SPECIFICATIONS 1.2 GENERAL SPECIFICATIONS s 11246 St GENERAL SPECIFICATIONS - LEGEND & ABBREVIATIONS ROOM NAME ROOM NUMBER BUILDING 8481 MK7CF90 REMODEL 13050 INTERURBAN AVE. S TUKINILA, WA 98168 INTERIOR FINISHES ELEVA11ON/DA11JM MARK EXTERIOR MATERIAL/FINISH EXTERIOR COLOR INTERIOR ELEVATION DETAIL NUMBER SHEET NUMBER CONDUIT CEMEN 11 MOUS BACKER BOARD CERAMIC TILE CONTRACTOR FURNISHED, CON TRACTOR INSTALLED DEGREE DIAMETER ELECTRICAL CON TRACTOR FLOOR DRAIN FIBERGLASS REINFORCED PANEL FLOOR SINK israfts, 590' ; suany Illi . • I I N 4. $ MM. Is Ai ip usait - SUM! SHEET INDEX VICINITY MAP Itos 410 6 7 7 , 1 ARCHITECTURAL INTERIOR DESIGN ELECTRICAL SPECIFICATIOIIS GA. G.B. C.C. GALV. H.D. HOW. INV. JIB OR (JIB.) Jock in the Box Inc. ANGLE it B. MACHINE BOLT MTL. METAL N.T.S. NOT TO SCALE O.C. ON CENTER OWNER FURNISHED, CONTRACTOR INSTALLED OPNG. OPENING P.C. PLUMBING CONTRACTOR PL PLATE Q.T. QUARRY 11LE RAD. OR (R) RADIUS SM SHEET METAL SMS SHEET METAL SCREW STL STEEL STRU CT. STRUCTURAL SUSP. SUSPENDED SW. SYMMETRICAL MK. THICKNESS T & G TONGUE & GROOVE U. B. C. UNIFORM BUILDING CODE U. 0.N. UNLESS OTHERVOISE NOTED VERT. OR (V) VERTICAL V.W.C. VINYL WALLCOVERING ND. %COD W. G. B. WATER RESISTANT GYPSUM BOARD I timb • t1":4 arm. • 41 lb • GAUGE (GAGE) GYPSUM BOARD GENERAL CON TRACTOR GALVANIZED HUB DRAIN HARDWARE HOLLOW METAL INVERTED - \ ■ " • e 111 - 4e1 .11 41. 41111h .-m As 4 111 „el" ... w • .e. . ■ ..- . (TOTAL OF 18 SHEETS) %re. &an 411 leet.t.rrED are 1. • .f. . 1111111 't... •• •.: ' , ..... I 41. Remove ern Remove existing flooring and base to original substrate Remove e� Remove existing flooring and base to original substrate Remove ex Remove existing wall finishes to substrate. Lower to 34' aff Remove knee wall fishes to substrate Instal Marite Wail Panel s - em Save Ice Maine refrigeration Und Compresses Drink stator and related components to be protected Lower cabnt height to 3C aff , Lighting Emergency lights Bug sapper Floors Tile , Floor Drain Clean Outs Drywall FRP Ceiling Ceiling tiles Hard lid . Emergency lights Water closet Paper towel dispenser Mirror Grab bars Soap dispenser Toilet per dispenser Seat cover dispenser Baby changing station Men's RR Finishes Hardware Door jambs Signage FRo Ceding Wes Hard id Alcove max - 24" deep: min 30" wide 1 Access rectangle 30"x Doors Finishes Hardware Door jambs Signage Tile . Floor Drain . Clean Outs Drywall FRP Turning radius minimum 5' Ceding tiles T -Grid Huard id IMES 1111111111111111111111111111 z - �� i;;''t . NOM= X © Remove exist • floorin • and base to on • • substrate Tile -�----MI- X Remove existing wall finishes to substrate. hstall 5/8" Gypsum Walt Board Remove emergency light and replace with Al facture Floor drains not to exceed 2% slope Finishes Hardware Door jambs leg Electrical Building Equipment (enter equipment needed) ltegrount KN Floor • Paint Kit C Install 5/8" water resistant Gypsum Wall Board •11111111111W := mil =man LCN (401114012) or (4041) used hstall 5/8" water resistant Gypsum Wall Board LCN (401114012) a (4041) used Ceiling tiles T -Grid Hard lid tieft an 1111111111111111111111 Will MI AM IIIIV 11111111111111111111111111 Budding trusses, joists, sheathing & roof structure Bearing Walls Stairwell Remove emergency light and replace with Al fixture Shelving Ladder/Roof Hatch .Air Curtain DT ;Air Curtain Back Door .Air Curtain Dining Room . Dishwasher Prep Table Sink Gen Rqmts: OH & Profit. Supervision. Gen :Conditions. Tax Electrical . Service Size .Main Distribution Panel Sub b Panels _ Crrcuiting/Vlfring :Other Electrical JIB 8481 REIMAGE SCOPE OF WORK � 1 1 !Inspected by CONKI ING ul • nU Inter' Prep Vlbrk Remove POS Registers and Monitors from Front Counter 'hstall Air Tight Barrier between Work Area & Kitchen Protect Existing Awnite Front Counter Protect security monitor Protect interior menu and breakfast board Remove protect existing security cameras for reuse leave connected, cover w/plastic and hang from structure Protect existing resin surfaces (trim & chair rail to ;remain) fining Vestibule Pictures Ceiling tiles T -Grid , Hard lid Supply air and return air • lIs Finishes Hardware Door jambs Light fixtures Exit signs Speakers Drywall Wallcovering T -Grid Hard lid Supply air and return air grills , Bug zappers Light fixtures Exit signs Speakers iorefrol t swish* Glazing Decor package Shmice dirt iltir Counter top Knee wall Warc-,=`.errg C eairg ties Hard 0sc SUpoti : and resin : X Tiie Drywa 1 Ceiling T -Grid x Hard li X R emove existing flooring and base to original substrate R emove existing wall finishes to substrate. Comments I JIB 8481 R estrooin Vest. tr; scrl Cty uk.v::a 011105 1 it Ris dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions I :'PIPES x 'zone JePOEZ'_Ei • INTERIOR S.O.W. TS1.1 • 0 INTERIOR SCOPE OF WORK 0 a • • s1 1 : 1 A(4 ) , i 9330 BALBOA AVENUE SAN DIEGO, CA 92123 © 1999 Jock in the Box Inc. These drawings and specifications ore the property of Jock in the Box Inc and shall not be copied or reproduced without its previous written consent • EAST ELEVATION S NORTH ELEVATION EQ. SOUTH ELEVATION T1 • GRRO CORATIIE- HIC. PANEL C PANNK 1o' - 1,. 1O' -r 'D CORATII& GRAPHIC. PANEL BETWEEN SHADOW CAST PAN r .' 'T1r.•. T• ...-.+ra,pv. ^.+ EQ. toe S FLOOR PLAN SCALE: 1/4" =1 -0' • ' • ,x ... -. •',T. -•- 3- •vT'-- ffaa"±v"�t'tar_���..-_ e*1+s.- • - - reeve _ r - _ - -' - rm. SCALE: 1 /4 =1' -0 WEST ELEVATION •• . • . •••■44.,1440..- a..•.m - _r..••.••_ •..- .r•- • •- - -- a -..r.. s I. S C A L E : T /4" # 1 ' - 0' cI .....1.11• •• r .--`." -.5.•/•P , . I • • • 4 • }; 1 EXISTING JIB SIGN TO REMAIN NOTES: 1. REPAINT BUILDING AS REQUIRED TO MATCH EXISTING. t i• - I f; 2. NEW GRAPHICS ON NORM. 54011 AND (NEST ELEVATIONS. TO BE PAINTED USING OWNER PROVIDED TEMPLATE. COLOR: JIB RED, SW CUSTOM COLOR. ,AB RED. EXTERIOR ACCENTS LATEX SATIN PRIMARY RED CUSTOM MATCH R3- 10Y63t11 TM COATS. JIB SHADOW RED. FIRST COAT - ,lB RED SECOND COAT - EXTERIOR ACCENTS LATEX SATIN PRIMARY SW 2915 SUN PRIED TOMATO THIRD COAT - JBRED. 3. ALL EXTERIOR GRAPHICS TO RECEIVE GRAFFITI BARRIER. DUMOND CPU 647 GRAFFITI BARRIER COATING. BY DUMOND CHEMICALS. 4. POP STRETCH FRAME OR SHADOW CAST PANELS AS NOTED ON Qfgff....MUJINQQN ELEVATION. PROVIDED BY OW ER, INSTALLED BY G.C. PER OIM€ERS INSTRUC1iONS. 5. SEE FLOOR PLAN FOR NEW EXTERIOR DOORS. f :`JIF.yc,'Y�C•. '- W e :`:rr•_ -�ca .••:• - • ' , .. -'_- -t .. . _-ra. +a�rslaru+na ee• :w.•x - .._.. - - ,eerw.l^*..�r.a,. w -- r�rry- ++rte � � - SCALE: 1 /4" =1' -O" REVIEV:EJFCF oDE com L.La ; li r),1 r. 111 T I c;..l of T L ,K ; ,,, , tia RI III oNo rvvtgr! meco or • rT © 1999 Jock 'm the Box Inc. These drawings and specificoticros ore the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent D rG / J c' AP r`4 r.4 /./ 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z W cc cc „tt 0 ›- ADDRESS: dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions Ilk TYPE: f M . 8 GP j E WIRES site information DRAM BY: SCALE: AS P OTED EXTERIOR ELEVATiONS A1.0 X PG as 0 cr'1 M r. OS 06 M1 MM LA W W r I REIMAGE SCOPE OF WORK le . 8481 1 ittspected by' CONKLING y • • d Q� ,r �� �� P Q � � . ilta ng adet v 'i . . • . ? 1- "1"- ;-; Y .' r•:! + - . - :� . . t - .. i - . .• • Roof/mansard X X Flat roof X X Soffit/pa rapet X X . Roof drains X X ,Wall Surfaces Block X X X WaN Surfaces Stucco X X X _ !Wall Surfaces Wood — X _ X I X ExitslDoors X X X . ;Glass & Glazing _Fascia X X Flyfans X X .Guard poles T X _ X • EAST ELEVATION S NORTH ELEVATION EQ. SOUTH ELEVATION T1 • GRRO CORATIIE- HIC. PANEL C PANNK 1o' - 1,. 1O' -r 'D CORATII& GRAPHIC. PANEL BETWEEN SHADOW CAST PAN r .' 'T1r.•. T• ...-.+ra,pv. ^.+ EQ. toe S FLOOR PLAN SCALE: 1/4" =1 -0' • ' • ,x ... -. •',T. -•- 3- •vT'-- ffaa"±v"�t'tar_���..-_ e*1+s.- • - - reeve _ r - _ - -' - rm. SCALE: 1 /4 =1' -0 WEST ELEVATION •• . • . •••■44.,1440..- a..•.m - _r..••.••_ •..- .r•- • •- - -- a -..r.. s I. S C A L E : T /4" # 1 ' - 0' cI .....1.11• •• r .--`." -.5.•/•P , . I • • • 4 • }; 1 EXISTING JIB SIGN TO REMAIN NOTES: 1. REPAINT BUILDING AS REQUIRED TO MATCH EXISTING. t i• - I f; 2. NEW GRAPHICS ON NORM. 54011 AND (NEST ELEVATIONS. TO BE PAINTED USING OWNER PROVIDED TEMPLATE. COLOR: JIB RED, SW CUSTOM COLOR. ,AB RED. EXTERIOR ACCENTS LATEX SATIN PRIMARY RED CUSTOM MATCH R3- 10Y63t11 TM COATS. JIB SHADOW RED. FIRST COAT - ,lB RED SECOND COAT - EXTERIOR ACCENTS LATEX SATIN PRIMARY SW 2915 SUN PRIED TOMATO THIRD COAT - JBRED. 3. ALL EXTERIOR GRAPHICS TO RECEIVE GRAFFITI BARRIER. DUMOND CPU 647 GRAFFITI BARRIER COATING. BY DUMOND CHEMICALS. 4. POP STRETCH FRAME OR SHADOW CAST PANELS AS NOTED ON Qfgff....MUJINQQN ELEVATION. PROVIDED BY OW ER, INSTALLED BY G.C. PER OIM€ERS INSTRUC1iONS. 5. SEE FLOOR PLAN FOR NEW EXTERIOR DOORS. f :`JIF.yc,'Y�C•. '- W e :`:rr•_ -�ca .••:• - • ' , .. -'_- -t .. . _-ra. +a�rslaru+na ee• :w.•x - .._.. - - ,eerw.l^*..�r.a,. w -- r�rry- ++rte � � - SCALE: 1 /4" =1' -O" REVIEV:EJFCF oDE com L.La ; li r),1 r. 111 T I c;..l of T L ,K ; ,,, , tia RI III oNo rvvtgr! meco or • rT © 1999 Jock 'm the Box Inc. These drawings and specificoticros ore the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent D rG / J c' AP r`4 r.4 /./ 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z W cc cc „tt 0 ›- ADDRESS: dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions Ilk TYPE: f M . 8 GP j E WIRES site information DRAM BY: SCALE: AS P OTED EXTERIOR ELEVATiONS A1.0 X PG as 0 cr'1 M r. OS 06 M1 MM LA W W r I C 1. PARKING 1. PROVIDE ONE (1 ACCESSIBLE PARKING STALL PER TWENTY -FIVE (25) TOTAL PARKING STALLS 2. 8 FT S96? MINIMUM WIDTH OF EACH PARKING SPACE. 3. MINIMUM FT (96 ") (WIDTH) ACCESS AISLE LOCATED ON PASSENGER SIDE. 4. SURFACE OF PARKING SPACE(S) AND ACCESS AISLE SHALL NOT EXCEED 1:50 GRADIENT (2.0%) IN ANY DIRECTION. 5. ACCESSIBLE PARKING SPACE(S1 MUST PERMIT USE OF ALL VEHICLE DOORS. 6. A PARKING BUMPER IS REQUIRED WHEN NO CURB OR BARRIER IS PROVIDED WHICH WILL PREVENT ENCROACHMENT OF CARS OVER THE ADJOINING ACCESSIBLE ROUTE. 7. WHEELCHAIR USERS MUST NOT BE FORCED TO GO BEHIND PARKED CARS OTHER THAN THEIR OWN TO ACCESS AN ADJOINING ACCESSIBLE ROUTE. 8. CURB RAMPS MAY NOT ENCROACH INTO THE REQUIRED DIMENSIONS OF ACCESSIBLE PARKING SPACES OR ADJACENT ACCESS AISLES. 9. ACCESS AISLE MUST CONNECT TO AN ACCESSIBLE PATH Of TRAVEL TO THE FACILITY. PARKING SPACE SIGNAGE EACH PARKING SPACE RESERVED FOR PERSONS WITH DISABILITIES SHALL BE IDENTIFIED BY A REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON DARK BLUE BACKGROUND. 2. SIGNAGE IS INSTALLED AT EACH SPACE. 3. AREA OF EACH SIGN(S) IS NOT SMALLER THAN 70 SQUARE INCHES. 4. WHEN POSTED IN A PATH OF TRAVEL, THE BOTTOM OF THE POLE - MOUNTED SIGN IS 80 MINIMUM FROM THE PARKING SPACE FINISH GRADE. 5. WHEN WALL MOUNTED, SIGN IS CENTERED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE AT A MINIMUM HEIGHT OF 60" FROM THE PARKING SPACE MINIMUM GRADE GROUND OR SIDEWALK. 6. VAN ACCESSIBLE PARKING SPACES HAVE ADDITIONAL SIGN MOUNTED BELOW SYMBOL OF ACCESSIBILITY THAT STATES "VAN ACCESSIBLE ". 7. FOR WASHINGTON STATE, EA. ACCESSIBLE PARKING STALLSIGN SHALL INCLUDE THE INTERNATINAL SYMBOL OF ACCESS AND THE PHRASE "STATE DISABLE PARKING PERMIT REQUIRED ". SITE ENTRANCE SIGNAGE 1. WARNING SIGNAGE REGARDING UNAUTHORIZED USE OF DISABLED PARKING � pES�. SHALL IMMEDIATELY AT EACH ENTRANCE AND VISIBLE FRO�MEEACH PARKING SPACE. PARKING SPACE STRIPING THE SURFACE OF EACH ACCESSIBLE PARKING SPACE OR STALL MUST HAVE A SURFACE IDENTIFICATION DUPLICATING EITHER OF THE FOLLOWING SCHEMES: 1. BY OUTUNING OR PAINTING THE STALL OR SPACE IN BLUE AND OUTLINING ON NE GROUND IN THE STALL OR SPACE IN WIHITE OR SUITABLE CONTRASTING COLOR A PROFILE VIEW DEPICTING A WHEELCHAIR WITH OCCUPANT: BY OUTLINING A PROFILE OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON BLUE BACKGROUND. THE PROFILE SHALL BE LOCATED SO THAT IT IS VISIBLE TO A TRAFFIC ENFORCEMENT OFFICER WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE AND SHALL BE 36" IN LEGTH BY 36" WIDE. BUILT -UP CURB AND CURB -CUT RAMPS GENERAL - ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF IT'S SLOPE EXCEEDS 1 FT (12") OF RISE IN 20 FT (240') OF HORIZONTAL RUN (5% OR GREATER). 1. WI0IH�OFRTHEN LENGTH �IALL�B LEAST �AS�NADE S AS THE CURB RAMP EXCLUDING FUIRES, LEADING TO THE LAN 3. SLOPE OF FANNED OR X FLARED SIDES�(SIDE SLOPES) DOES NOT EXCEED 1 : 10 GRADIENT (10%). 4. CROSS SLOPE DOES NOT EXCEED 1 : 50 GRADIENT 2.OX. 5. FINISHED SURFACE OF RAMP CONTRASTS FROM ADJACENT SIDEWALK, AND IS STABLE, FIRM AND SUP RESISTANT (MEDIUM BROOM FINISH OR EQUIVALENT ). 6. CROSS SLOPE OF LANDING AREA DOES NOT EXCEED 1 : 50 GRADIENT 2.ox . 7. AMP S) DOES NOT PROJECT INTO VEHICULAR TRAFFIC LANES. 8. TRAM 110NS FROM RAMPS TO WAD( GUTTERS OR STREETS ARE FLUSH AND FREE OF ABRUPT CHANGE. 9. A 12" GROOVED BORDER IS PROVIDED ALONG THE TOP AND SIDES OF NE RAMP AT NE LEVEL SURFACE OF THE SIDEWALK (GROOVES APPROXIMATELY 3/4" ON CENTER, 10. CURB RAMP SHALL HAVE DETACTABLE WARNINGS. NNOTEE:C REQUIREMENTS ARE IN ADDITION TO THOSE USTED ABOVE. IF 1. MARKED CROSSINGS THAT ARE RAISED TO THE SAME LEVEL AS THE ADJOINING SIDEWALK SHALL BE PRECEDED BY A 24 INCH DEEP DETACTABLE WARNING COMPLYING WITH SECTION 705 /ICC ANSI 2003, EXTENDING NE FULL WIDTH OF THE MARKED CROSSING. 2. INHERE DETACTABLE WARNINGS ARE PROVIDED ON CURB RAMPS THEY SHALL BE 24 INCHES MINIMUM IN NE DIRECTION OF TRAVEL AND EXTEND THE FULL WIDTH OF THE CURB RAMP OR FLUSH SURFACE. 3. NE DETACTABLE WARNING SHALL BE LOCATED SO THE EDGE NEAREST THE CURB UNE IS 6 INCHES TO 8 INCHES FROM THE CURB UNE. THRESHOLDS 1. fLOOR(SR LANDINGS ARE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE - THRESHOLD OF THE DOORWAY. 4 _ 2. CHANGE IN LEVEL BETWEEN 1/4.. AND 1/2" IS BEVELED AT A GRADIENT OF 1:2. NOTE: A 1/4' MAXIMUM VERTICAL EDGE IS ALLOWABLE AT 3. DOORMATS ARE SECURELY ATTACHED ANCHORED OR RECESSED) AND HAVE A LEVEL LOOP. LEVEL CUT/UNCUT PILE WITH PILE NOT EXCEEDING 1/2" IN HEIGHT. 4. EXPOSED EDGES OF DOORMAT S)ARE FASTENED TO FLOOR SURFACES,..AMD HAVE TRIM ALONG THE EN LENGTH OF THE EXPOSED EDGE. . DOOMS 1. MINIMUM OF 3 FT(36_) IN WIDTH 6' -8" (80 ") IN HEIGHT. 2. OPENS A MINIMUM OF 90 DEGREES. ' 3. CLEAR WIDTH OF THE DOORWAY IS 32" MINIMUM. 4. DOUBLE DOORS 1 AUTOMATIC DOORS - AT LEAST ONE DOOR MUST COMPLY WITH 1, 2 AND 3 ABOVE. 5. ALLLOW DOOR OF DOOR BE HAS OPEENED BY A LCHMIR FOOTREST SURFACE THAT CREATING A TRAP OR HAZARDOUS CONDITION. NOTE: INHERE NARROW FRAME DOORS ARE USED, A 1O- ITCH -HIGH SMOOTH SMOOTH PANEL MUST BE INSTALLED ON THE PUSH SIDE OF THE WHICH 1MLL ALLOW NE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. 6. EFFORT TO OPERATE DOORS IS WITHIN PRESSURES ALLOWED. INTERIOR DOORS - 5 POUNDS MAXIMUM PRESSURE TO OPERATE. EXTERIOR DOORS -&5 POUNDS MAXIMUM PRESSURE TO OPERATE. FIRE DOORS - 15 POUNDS MAXIMUM PRESSURE TO OPERATE 7. TWO DOORS IN A SERIES PROVIDE A MINIMUM OF 48" CLEAR SPACE FROM ANY DOOR P4 ANY POSITION. DOOR HARDWARE 1. EXIT DOORS ARE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY CR ANY SPEOAL KNOWLEDGE OR EFTORT. 2. LATCHING ING AND LC CII*4G DOORS THAT ATE HAND OPERATED ARE OPERABLE PATH A SINGE EFFORT (Dl LEVER T'!PE. PAC BARS OR PUSH-POLL TYPE). 3. OPENING HARDWARE iS CENTERED BETWEEN 30' M4; 44' ABOVE Fes+ F;.00R. 4. DOOR CLOSERS. F PRESENT. MUST BE SE" SO NAT I T TAKES AT LEAS' 3 SECONDS TO CLOSE FROM AN OPEN POST ON CO' '0 DEGREES TO WM TIC 3" OF THE LATC>r± CLEAR SPACE AT DOOM GENERAL - REGARDLESS OF THE 3C AN .CA T SHALL BE A ' JR LANCING Oi4 EACte 90E OF A DOOR t FLOOR OR LAMING ON EAcH 90E OF THE DOOR S LEA, MC ca AR EVE1 AR �OM A N THE DIIRECT O: THE SING :5 A WARM OF 60' it 3 LEVEL AREA JP�'9'E T1{ DIRECTION OF '' DOOR SUNG S A ~AN OF 44' -4a' N ..DOGTH DEFENDING UPON DIRE C TION OF APPROAO9 AND t STENCIL cF ;.ATCN MO CLOSER. 4. SURFACE SLOPE OF THE LEVEL AREA DOES IrOT EXCEED 7 : 50 GRADIENT 5 ativ S1RlcE SIDE CLEARANCE ON PUS SIDE OF DOOR IS PROVIDED A 6. LANDING, LATCH 90E asfausa Ox FkISI4 SLOE OF DOOR IS PROVIDED AI LAN�1G Is IDENTIFICATION SYMBOLS (FOR SANITARY FACILITIES) NOTE: SANITARY FACILITIES ARE REQUIRED 10 PROVIDE TWO SEPARATE TYPES OF SIGNAGE: ONE TYPE LOCATED ON THE DOORWAY OF THE FACILITY, AND ANOTHER TYPE LOCATED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. DOOR MOUNTED SIGNAGE 1. (MEN'S)- EQUILATERAL TRIANGLE 1/4" THICK WITH EDGES 12" LONG AND A RTE POINTING UPWARD. 2. WOMEN''S)- 12' DIAMETER CIRCLE 1/4" THICK. 3 UPER ) IMPOS ED WITM T C RE LE 1/4" " THICK WITH 1/4" THICK TRIANGLE 4. THE CHARACTERS AND BACKGROUND OF THE SIGN IS EGG -SHELL OF THE OR OTHER DR DISTINCTIVELY NON-GLARE FINISH WITH EO THECO LOR AN DC A CONTRAST OF THE DOOR. 5. SIGNS ARE CENTERED ON THE DOOF 60" FROM THE FLOOR. WALL MOUNTED SIGNAGE 1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. THE BORDER DIMENSION OF THIS PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. NOTE: WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. 2. VERBAL DESCRIPTION AS TO RESTROOM USAGE (I.E. MEN'S RESTROOM, ETC.) IS PLACED DIRECTLY BELOW THE: SYMBOL OF ACCESSIBILITY. 3. THE CHARACTERS AND BACKGROUND OF THE SIGN IS EGG-SHELL, MATTE OR OTHER NON -GLARE FINISH AND THE COLOR AND CONAST OF THE SIGN DISTINCTIVELY CONTRAST WITH THE COLOR AND CONTRAST OF THE WALL. NOTE: THE REQUIRED CDLOR OF NE SYMBOL OF ACCESSIBILITY CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. HOWEVER NE APPROPRIATE ENFORCEMENT AGENCY MAY APPROVE SPECIAL t1GNS TO COMPLIMENT DECOR WHEN SUCH SIGNS PROVIDE ADEQUATE DIRECTION TO INDIVIDUALS 'MTH DISABILITIES. 4. SIGNS ARE CENTERED ON THE WALL 60" FROM THE FLOOR. 5. LETTERS AND NUMERALS ARE RAISED 1j32", ARE SANS -SERIF UPPERCASE CHARACTERS AND ARE ACCOMPANIED BY GRADE 2 BRAILLE. CHARACTERS ARE A MINIMUM 5/8" HIGH AND A MAXIMUM OF 2" HIGH. 6. MOUNTING LOCATION ALLOWS A PERSON TO APPROACH WITHIN 3" OF THE SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. SANITATION FACILITIES SINGLE ACCOMMODATION TOILETS 1. ACCESSIBLE UNITS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. 2. EXCEPT AT DOORS, THE MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE IN FACILITY IS 36 ". 3. ENTRY DOOR HAS PRIVACY LATCH (PUSH BUTTON -LEVER RELEASE) 4. SUFFICIENT SPACE FOR WHEELCHAIR MEASURING 30" X 48" TO ENTER ROOM AND PERMIT THE DOOR TO CLOSE IS PROVIDED. 5. A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60" MINUMUM DIAMETER CIRCLE IS PROVIDED WITHIN THE SANITARY FACILITY ROOM. 6. 60" DIAMETER MINIMUM SPACE IS CLEAR OF OBJECTS FROM NE FLOOR TO A HEIGHT OF 27 ". 7. 48" MINIMUM CLEAR SPACE IS PROVIDED IN FRONT OF NE WATER CLOSET. 8. 18" HOLD DIM. BETWEEN CENTER OF WATER CLOSET AND SIDE -WALL CORNER. 9. 28" MINIMUM CLEAR SPACE IS PROVIDED FROM THE WATER CLOSET TO ANY FIXTURE, OR A MINIMUM 32" WIDE CLEAR SPACE TO THE OPPOSITE WALL 10. TOP OF TOILET SEAT IS 17" - 19" FROM FLOOR SURFACE. 11. FLUSH VALVE IS ON WOE SIDE OF TOILET AREA. 12. 5 LB. MAXIMUM FORCE TO OPERATE FLUSH VALVE. 13. WALLS WITHIN COMPARTMENT ARE SMOOTH, HARD AND NON- ABSORBENT TO 48" IN HEIGHT, AND ARE NOT ADVERSELY AFFECTED BY MOISTURE. 14. FLOOR SURFACES OF TOILET ROOM ARE SMOOTH, HARD AND NON- ABSORBENT EXTENDING UPWARD A MINIMUM OF 5" ONTO WALLS. 15. SIDE GRAB BAR IS A MINIMUM OF 42" LONG AND EXTENDS 24" BEYOND THE FRONT OF THE WATER CLOSET. 16. THE FORWARD END OF THE GRAB BAR IS LOCATED A MINI- MUM OF 54" FROM THE BACK WALL. 17. SIDE GRAB BAR BEGINS A MAXIMUM OF 12" FROM THE REAR WALL 18. REAR GRAB BAR IS A MINIMUM 36" LANG. 19. REAR GRAB BAR BEGINS A MAXIMUM OF 6" FROM THE CORNER OF NE WALL ON THE TOILET SIDE. 20. DIAMETER OF GRAB BARS IS 1-1/4" - 1-1/2" OR SHAPE PROVIDES EQUIVALENT GRIPPING SURFACE. 21. CLEARANCE BETWEEN THE GRAB BAR(S) AND WALL IS 1-1/2". 22. GRAB BARS ARE MOUNTED AT 33" TO CENTER OF BAR ABOVE AND PARALLEL TO FLOOR. (FOR TANK TYPE TOILETS, 36" MAY BE ALLOWED F TANK OBSTRUCTS PLACEMENT OF BAR). 23. EDGES OF GRAB BARS ARE SMOOTH WITH A MINIMUM RADIUS OF 1/8 ". 24. MINIMUM STRUCTURAL STRENGTH OF GRAB BAR(S) WILL SUPPORT A 250 LB. POINT LOAD. 25. GRAB BARS DO NOT ROTATE WITHIN THEIR FITTINGS. 26. SURFACE OF WALL ADJACENT TO GRAB BAR(S) IS FREE OF SHARP OR ABRASIVE ELEMENTS. 27. CENTER LINE TOILET PAPER DISPENSER IS LOCATED ON THE WALL WITHIN . 7" MIN. TO 9" MAX. OF THE FRONT EDGE OF THE TOILET SEA 28. 19" MINIMUM HEIGHT FROM FLOOR TO CENTERLINE OF ?SET DISPENSER. (LOCATE BELOW GRAB BAR 1 -1 /2 " M ' 29. TOILET PAPER DISPENSER ALLOWS CONTINUOUS PAPIER KM MIND NOT CONTROL DELIVERY. t, LAVATORIES • 1. MINIMUM 30" X 48" t EAR SPACE 5 PROVIDED IN FRONT OF"1`AYA ORY THAT ALLOWS FORWARD APPROACH. 2. REQUIRED ,CLEAR SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROOTk: ..- OTENDS A: MAXIMUM OF UNDERNEATH THE LAVATORY. . ,. 3. } LAVATORIES ADJACENT TO A SIDE-- HAVE A MINIMUM 187 DISTANCE TO �': CENTER OF FIXTURE. • 4. - 34" MINUMUM .HEIGHT OF RIM OR CDUN.TER ABOVE FINISH FL SURFACE. 5. .29" MINIMUM CLEARANCE FROM BOTTOM Qf APRON TO THE FLOOR. 6. ` KNEE CLEARANCE UNDER FRONT UP IS A 1I NIWUM OF 27' 1001, 30" WIDE, - ;AND EXTENDS A MINIMUM OF 8" IN DE_P1WFROMM THE FRONT OF THE 7. :.TOE CLEARANCE UNDER LAVATORY IS A MINIMUM OF 9' HIGH 30" WIDE, AND VI INM DS A MI I OF 17` IN DEPTH FROM THE FRONT OF THE LAVATORY. 8. AND HOT WATER PIPING IS INSULATED OR CONFIGURED TO PREVENT 9. THERE CONTACT„,- SHARP OR ABRASIVE ELEMENTS UNDER LAVATORY. 10. FAUCETS ARE LEVER TYPE, ELECTRONICALLY ACTIVATED OR APPROVED SELF 11. =SING ARE OPERABLE MTTH SECOND H FLOW). DO NOT REQUIRE TIGHT GRASPING, INCHING OR TWISTING OF THE MIST. 12. 5 LB. MAXIMUM FORCE REQUIRED TO ACTIVATE CONTROLS. URINALS 1. MINIMUM 30" WIDE X 48" DEEP CLEAR ACCESS SPACE AS SF** ON DET. 4/A2.0. (ONE FIXTURE ONLY REQUIRED). 2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR FLOOR SPACE. 3. 17" MAXIMUM RIM HEIGHT ABOVE FLOOR. 4. 44' MAXIMUM HEIGHT OF FLUSH VALVE ABOVE FLOOR. 5. 5 LB. MAXIMUM PRESSURE TO OPERATE FLUSH VALVE. 6. 14' MINIMUM PROJECTION FROM WALL 7. FLOOR SURFACES ARE SMOOTH, HARD AND NON - ABSORBENT EXTENDING UPWARD A MINIMUM OF 5' ONTO WAL _S. 8. WALLS WMTMN 24' OF FRONT AND SIDES OF URINAL ARE SMOOTH, HARD AND NON - ABSORBENT TO 48' 'N HEIGHT, AND ARE NOT ADVERSELY AFFECTED BY MOISTURE. ACCESSORIES IN SANITARY FACILITIES r . MINIMUM 30" X 48" CLEAR FLOOR OR GROUND SPACE IS PROVIDED TO ALLOW FORWARD OR PARALLEL APPROACH T(' ACCESSORIES. 2. ONE FULL U'NOBSTRUCT SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS OR OVERLAPS AN ACCESS= ROUTE OR ADJOINS ANOTHER WHEELOHAIR CLEAR F ;RJR SPACE_ 3. MIRROR( S) IS OUN TEC WON THE BOTTOM OF THE REFLECTIVE SURFACE EDGE NO ►DER 40' FROM THE FLOOR_ 4. OPERABLE PARTS (h�.AyNG COIN SLOTS) Cr ALL FIXTURES OR ACCESSORIES ARE LOCA TED A WAXLI Al OF 40' ielvE FLOOR (I.E SOAP 0iSP'E1r5F.RS. TOOLS. TOILET SEA' "C�fRS AUTO - DRYERS. SANITARY UPON DISPENSERS. WASTE RECEPTACLES. E TZ. )- 5. CONTROLS AND OPERA-IC MECHANISMS ARE OPERABLE WITH ONE HARD MD 00 NOT REQUIRE 1 04T GRASPING, PIMPING, OR Ttl/S,ING OF 1HE VRIST. 6. THE FORCE TO ACTTva COM1S IS 5 L.H. W1 Rl I 6, MSS S AT Flo LEFT ARROW SIGN (USE CHECK BOX ONLY) El MOUNT SIGN TO FACE OF BUILDING PER SIZE PLAN El MOUNT SIGN ON POST � MOUNT SIGN PER DE7A� x- dt003aILDWMa16 'VAN ACCESSIBLE' HANDICAP PARKING SIGN (TYP) PER DET. 10/A2.0 N9TES: 1. PROVIDE (N) OR RELOCATE EXIST'G WHEEL STOP AS REQ'D TO PREVENT ENCROACHMENT OF CAR OVER ADJOINING ACCESSIBLE ROUTE. SEE DET. 16/A2.0 2. SURFACE OF PARKING SPACE AND ACCESS AISLE SHALL NOT EXCEED 1:50 GRADIENT (2.0% IN ANY DIRECTION). INTERNATIONAL SYMBOL OF ACCESSIBILITY STALL EMBLEM PER DET. 10/A2.0 rwc013.O I e SINGLE PARKING SPACE DESIGN LA- 4 Co 0 PER DETAIL 12/A2.0 o 0 HC DIRECTIONAL DOOR (GP1 RIGID x, : -w1104.46 (USE CHECK BOX ONLY) El MOUNT SIGN TO FACE OF BUILDING PER SITE PLAN MOUNT SIGN ON POST PER DETAIL 12/A2.0 HC CROSSING SIGN 1INt A.G.A A.G. CLEARANCE REQUIRED L 1 • 36' N.T.S. i CONCRETE WHEEL STOP 6' 0 0 OF STALL ACCESSIBLE ROUTE z ME C' MOW f 8 FT(96 ")MIN. STALL WIDTH RIGHT ARROW SIGN (USE CHECK BOX ONLY) MOUNT SIGN TO FACE OF BUILDING PER SITE PLAN CONCRETE r rm STOP (*ERE OCCURS 1 1 ff = I s 8 FT(96 ")MIN. AISLE WIDTH MITE REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL WMTH BEADED TEXT OR EQUAL NOTE: SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE AREA OF SIGN TO BE A MIN OF 70 SO. IN. DESIGNATE FOR "VAN ACCESSIBLE" WHERE APPROPRIATE EMBLEM MUST BE LOCATED IN STALL SO THAT IT IS MIST BY A TRAFFIC _ ENFORCEMEN , ?, OFFICER,_ MI1E'N A VEHICLE IS PROPERLY PARKED IN THE ': , SP. (CENTERED AT • 1.�Y =a ENTRANCE TO STALL RIENDEDD r" - 39" MIN. TO 41' MAX. 12" MIN. L • o S± 1/2" RADIUS GREEN 54" MIN. PARKING WARNING SIGN PER DET. 11/S02.0 FACE OF BLDG. CURB g s WQ 42' MIN. REFER TO SITE PLAN SHEET TS1.0 PARKING SPACE SIGNAGE z Iv akni, Ng CHECK eor aid MINING sos post _ '.m V T 90uA10 36" FLUSH VALVE TYPE ACCESSIBLE WATER CLOSET SIGNAGE. PROVIDED & r.1 N BY CONTRACTOR, SEE DETAIL 10/A10 1 3/4' SO. GALv_ STL POST SET M CONC. FOOTING 1 3/4" SO. GALV. S1L POST SET INTO CONC. FILLED BOLLARD r VIDE REFLECTIVE OM TAPE 6' D A CALv. PPE FILLED W/ cow_ PAINT PER OTY STANDARDS Mom PARKING SIGN POST 11111111 AND WITHOUT mum 36" MIN. 24" MIN. RESERVED PARKING rz ewes .ow .a.. imam r- 4- 1 /8" = 1' -O" 1/2" = '. -Os 12" I MMIN. 6" ✓ ' MAX. FRONT VIEW 1/2" = 1 • _0 . CONC. FOa Ng OM NI OILY) n PANNING SIGN POST 1 - 1 IMAM 3,Ar r-d* z WA0005.DWCG124 1 -1/4" MIN. TO 1 -1/2" MAX. NOMINAL DIAMETER T240060Wi l2 1 1877 RESTROOM WALLS ;88 HEIGHT LETTERING 5 I� 10 2" aim 1/3r MIRROR LAVATORIES ACCESSORIES 119201 DOOR YOU N1ED 9GNAGE ' DISPENSER 1883 3803 NO OBJECT CLOSER THAN 1 1/2" TO GRAB BAR FACE OF WALL i DOING WALL IC AO' ACCESSIMUIY 000R DECALS MU MOUNTED SIGNAGE TO BE LOCATED ON LATCH 910E OF DOOR CLEAR OF DOOR MOUNT AT SO' lO �rnotNE OF 91a1 FROM GRID M 11111IILLE UP * CASE ULTRAS DISTRIBUTION AccEssumunr =GNAW SIZE & SPACING OF GRAB BARS RE\ ` 1 Ft'``ED FOR CODE C 3 LIAN., k It '‘v L- OW Of Tu(WI =a Fit ITIMG nI.NITcynni 119371 3804 DRYER 118891 ® (c4 my) 118921 !pail • NTS SEAT SOAP COVER DISPENSER DISPENSER 1/2" = 1 ! PAPER TOIL DtR Nom PIcTOCRAms AND/OR LETTERING ARE NOT REQUIRED ON 000R roUNTEn 90+AGE NTS 3fi = 1•-4r N z MIN. ctEP Svc Fl OR ��O BE WITHIN 14114- h�ets 12' MIN. DOOR CLE REQUIRED WHERE B4'; OSER AND LATCH ARE PR woo x I z I • �coarrw� 6 IAA 0 18" HOLD I X • qty SINGLE ACCOMODATION TOILET 18 6 HOLD MULTIPLE ACCOMODATION TOILET STALL UDE VVEW \ N 36" MIN. { 60' DIA. MIN. 60" MIrJ. FLUSH ACTIVATOR ON MADE SIDE f< 60" MINK. STALL WIDTH S FLUSH ACTIVATOR ON WIDE SIDE 18" MIN. • 3 3 ci f• a a STALL DOOR SHALL NOT SWING INTO THE MINIMUM REQUIRED STALL AREA 1. I . got N • STALL DOOR SHALL BE LOCATED IN THE FRONT PARTITION FARTHEST FROM THE WATER CLOSET. DOOR SHALL BE SELF- CLOSING I a 0 I PLAN VIEW 1/2" = 1' -0" 1/2" = 1 -0" Tir s1' -0 a 1999 Jack n the Box Inc. 9330 BALBOA AVENUE SAN DIEGO, CA 92123 These drawings and specifications are the property of Jack in the Bo. In and shall not be copied or reproduced without its previous written consent Z 0 D DRAWN BY: „1( . J E E NE ' dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions Z s W °' Cro cr kJ v •- x + '0 Q "- its - s U a, QO ,10.‹ ow. a, o ac o0 4 o c en m s= I 7 1j. 7:; U I +: C � N tn e o' ao ao � E EPODE S .r r : ; 2006 site information MI( TYPE J8 f Ir ADDRESS: it • J- ... �.. SCALE: AS SHOW ACCESSIBiLITY REQUIREMENTS WAC51. 6o A2.0 - inii • . in .. , ..-: g q.2 • &t �;: r iii Iii ? .,..., f 1 I ' .` yi; �l A \ ~ [ . • �•A .....,-K7 .. , '....'. A.• . - at 1 illEffilligliti , i • .' ?( ".' Wi 4 L Wall- Mounted Flat Screen Monitor(s) • Contractor shall provide and install a duplex "clock outlet" behind each woll- mounted flot screen monitor with a dedicated 120V, 20A circuit, fed from a 20A breaker (3 # 12 AWG in )1" conduit). Install clock outlet at centerlines of flat screen monitor(s). All flot screen monitors (up to 9) con be served by the same dedicated circuit. • Contractor sholl provide and install a 2" PVC conduit from 6" above the ceiling down to 2" above the centerline of the clock outlet and 5" to the right of the clock outlet. Provide and Install a double gong mud ring on the centerline of the 2' PVC conduit (vertically) and the centerline of the clock outlet (horizontally). • The wall - mounted flat screen monitor will be provided and Installed by others. The installer will also be responsible for the running of the communication cable and all final connections. FURNITURE PLAN NOTES 3. ALL TABLE TOPS SHALL BE ATTACHED TO BASE PER MANUFACTURER'S INSTRUCTIONS. 8. SEE DETAIL SHEETS FOR BLOCKING AT COUNTER TOPS �.a..�.�..A,.. -�..,.-. -..► •-...- .. ! .. - -.. ...11.11. 1 _. •._. -" r 1. ALL DIMENSIONS ARE TO FACE OF FINISHED DRYWALL AND ARE CONSIDERED CRITICAL UNO. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH SHOP DRAWINGS AND PLANS AGAINST REQUIRED CLEARANCES. 2. REFER TO INTERIOR DETAILS AND FINISH SCHEDULE FOR MORE INFORMATION. 4. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL QUANTITIES BEFORE ORDERING AND INSTALLING MATERIAL 5. ALL EXPOSED FINISH CORNERS AND SEAMS REQUIRE CAULKING. IN ADDITION, BUT NOT LIMITED TO ALL FIXED EQUIPMENT, ALL AVONITE SEAMS, BACKSPLASH AT BAR TOP. ETC. DO NOT APPLY CAULKING TO ANY VWC SURFACE. 6. GENERAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL, MECHANICAL AND PLUMBING WITH NEW INSTALLED EQUIPMENT. 7. FINAL SEATING LAYOUT SHALL COMPLY MATH THE LATEST EDITION OF THE AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDEUNES (A.D.A.A.G.) AND ALL LOCAL CODES AND ORDINANCES. Sal` -Save Kiosk at the Front Counter EMPLOYEE ROOM fT _ - 1 • L J INSTALL NEW OUTLET FOR idUSIC SYSTEM. SEE ELECT. DINGS. FOR ADO'L WO. (C.F. C.I. ) I r 1 f • O -H 2' -6" f 3'- O MEN'S (MCC HT- d' -O" ( 9. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT ANY SPECIAL KNOWLEDGE OR EFFORT OR THE USE OF A KEY. ALL INTERIOR DOORS SHALL BE LABELED "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED ". PER I.B.C. 1 0. POST OCCUPANCY LOAD SIGN (JIBg1889) IN CONSPICUOUS PLACE NEAR MAIN EXITS AT 6' -10" A.F.F. PER I.B.C. SECT. 1007.2.6. PROVIDE TOP & BOTTOM AND CAULK AROUND ALL SIDES. SIGN TO READ: "MAXIMUM SEATING CAPACITY - 67 SEATS ". EQ. 1 a if 4i VYOKSTdT10N 11. ALL FINISH SURFACES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF CLASS III OR HIGHER (FLAME SPREAD INDEX 76 THROUGH 200 & A SMOKE DENSITY RATING OF 450). 12. ALL DRAPES, CURTAINS & DECORATIVE MATERIAL PROVIDED AND /OR INSTALLED BY THE GENERAL CONTRACTOR SHALL BE MADE FROM NONFLAMMABLE MATERIALS OR TREATED WITH FLAME RETARDANT AS APPROVED BY THE LOCAL FIRE MARSHAL 13. ANY TIME THE BUILDING IS OCCUPIED, THE MEANS OF EGRESS SHALL BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOT- CANDLE AT NE FLOOR LEVEL. PER I.B.C. 14. PROVIDE EXIT SIGNS FOR EGRESS IDENTIFICATION PER I.B.C. 15. PROVIDE APPROVED EGRESS ILLUMINATION AND ILLUMINATED EXIT SIGNS PER I.B.C. " 1111111-11 F 1< It- - ____) MEN'S 14 r ! •••••• - ,p....- +►._ _ _ �..�.. .� °: tom : ■•■ 7 �.... ,...��.�... �.�".,-- .-.... .. 3' -10' .�i Cortractor seal provide and install a duplex receptacle on the `service side of the par y w below the front service counter .Id+ a dedicated "20V. 20A circuit, fed from a 20A breaker (3 9 12 ANG n r conduit). Instate receptacle at 28" AFT and tiredly bet:ind the self -save Kiosk or cs drected by the construction mvnoger • The self -serve kiosk wile be provided and installed by others. The ins«ier .i also be r ponsale for the running of the car - erlU rieotron calb+e avid all final comedians. • Contractor shall provide and install a duplex receptacle in the low alvidr; .eM .Fitt+ a dedicated 120V. 20A c arit fled frorn a 20A breaker (3 # ;2 *w; r y4 .sotN ► : =:; instal receptacle at 1 A' AFT and (*redly behind to* setf -serve kiosk or as (fretted by the cc r's`. uctice r onOger a : tractor shoo provide ar+C instal 4' . 4` : cow and 1' oo"dit •din pui .ire ct t8 AFT and 5 to the rit of tl+e _ duvet receptacle. ur w Run conougt do_ drvid mil. . under floor. them up to underside of front counter counter an 'service ode at .9' Aft Scwcut floor cr.! as 'enured for the installation of the conduit, paten =rd repair to mta wasting. • The self -serve kiosk ad be provided and totalled by others. The irstaker ea also be rlpormie for the running of the cornrnurucobari calm and all final connections. 1' -10' I I II I 11 �; ifil'ORICSTATRAIJ - - VEST 1 1 f5' -10' (EPA 1=:1 4 ==41- 11 / 4 WOMEN'S+ 1 I • • 1 PER 9,b SOME 10 (E SERVICE E'CSTNG KITCHEN AREA TO REMAIN UNCHANGED. t r 13 • = - -• _ - -- = - - -�/ .J■ • I , • r- - EQ. } U DINING .�_ LAW WILL Pu grt Id e REFLECTED CEILING PLAN I ---- - - - - -- �D • r CEILING ABOVE DRINK STATION SHALL BE A SMOOTH WASHABLE SURFACE, SEE INT. FIN. SCH. • • r . 5 -9' FURNITURE DIMENSION PLAN TAP. r ±9' a vir Fr) I tae Oi 1 . GENERAL CONTRACTOR TO PROVIDE HEALTH DEPARTMENT APPROVED TEMPORARY RESTROOMS FOR USE BY JIB EMPLOYEES THROUGHOUT DURATION OF PROJECT. • ALL DEMOLITION WORK SHALL BE COORDINATED MATH THE ENTIRE SET OF CONSTRUCTION DOCUMENTS TO DETERMINE EXTENT OF SITE AND BUILDING DEMOUTION. • GENERAL CONTRACTOR TO PROTECT AND STORE ALL IDENTIFIED EXISTING ITEMS THAT ARE TO BE REUSED/RE- INSTALLED. 5. REFER TO INTERIOR DETAILS AND INTERIOR FINISH SCHEDULE FOR MORE INFORMATION. GENERAL NOTES GENERAL CONTRACTOR TO INSTALL AIR TIGHT BARRIER BETWEEN WORK AREA AND FOOD AREAS. Bing Huns Flat Screen Monitor(s) • Contractor shall provide and install a duplex receptacle within 6" of the support pole for the ceiling hung flat screen monitor. The electrical circuiting is the some as that for the wall mounted flat screen monitor • The cuing - hung flat screen monitor will be provided and installed by others. The instiller will also be responsble for the running of the communication cable and all final connections. NOTE: "EQ12 (RED TRACK) WILL NOT BE PHYSICALLY ATTACHED TO TYPE 'C' FIXTURES AT THIS LOCATION. TRACK SHOULD BE RUN IN CLOSE PROXIMITY TO THE FIXTURE, BUT WILL NOT ATTACH' CEILING PLAN NOTES 1. INSTALL ACOUSTIC CEILING TILE (ACT) PER MANUFACTURER'S INSTRUCTIONS. SEE DETAILS FOR MORE INFORMATION. 2. ALL UGHT FIXTURES SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. PENDANTS SHALL BE CENTERED ON TABLE UNO. IN GENERAL, FIXTURES SHALL BE ALIGNED AND LOCATED AS SHOWN HEREIN. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. 3. REFER TO DETAILS AND INTERIOR / EXTERIOR ELEVATIONS FOR MORE INFORMATION AND LOCATIONS. 4. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBIUTY TO VERIFY ALL QUANTITIES BEFORE ORDERING AND INSTALLING MATERIAL 5. NOT USED 6. ALL GRILLES, FIXTURE TRIM, SPEAKERS AND UNITS LOCATED IN CEIUNG SHALL BE FINISHED TO MATCH THE ADJACENT CEIUNG FINISH COLOR. 7. DIMENSIONS ARE FROM FINISH FLOOR AND / OR FINISHED DRYWALL 8. LATERAL FORCE BRACING FOR SUSPENDED ACOUSTIC TILE CEIUNG: LEGEND A. PROVIDE (4) f12 GAUGE WIRES SECURED TO MAIN RUNNER WITHIN 2' OF CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT ANGLE NOT TO EXCEED 45 DEGREES FROM PLANE OF CEIUNG. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12' -O" O.C. IN BOTH DIRECTIONS WITH FIRST POINT WITHIN 4' -0' OF EACH WALL PROVIDE SOUD ATTACHMENT OF THE RESTRAINT WIRES TO STRUCTURE ABOVE. B. INSTALL COMPRESSION STRUT TO THE MAIN RUNNER AND EXTEND TO AND FASTEN TO STRUCTURE ABOVE AT 12' -0" O.C. EACH DIRECTION OR EVERY 144 S.F. OF CEIUNG AREA PER U.B.C. SIDS. 25-2. PENDANT LAMP MOUNTING HEIGHTS 1. 2. 3. PENDANT ABOVE BAR TOP LOCATED AT 6' -O" A.F.F. PENDANT ABOVE ROUND TABLE TOP LOCATED AT 6'- O'A.F.F. PENDANT ABOVE LOW TABLE TOP LOCATED AT 5- O'A.F.F C. D. CORE DRILLED TABLE P. L PENDANT LIGHT FIXTURE EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED gall PEW CONSTRUCTION ( CB 4 0 MOISTURE RESISTANT REGIONS PROVDE THE FOu.0WING MOISTURE RESISTANT MATES. SEE SPECIFICATIONS FOR OTHER DETAILS 1_ DINS S MNd .IE lit FACED INSULATION AT EXTERIOR STUD WALLS N lEU OF KRAFT FACED INSULATION_ 2_ t O QA PACIFIC D NSARYOR PLUS INTERIOR FMiEGUARD TYPE X GLASS MAT GYPSUM BOARD 14 I.IEJ GL PAPER FACED GYPSUM BOARD. .3. INSTALL LIVE MILL COWERING NTH 2INSSER PLUS a= NC NUM PROS COMM& Mu. mem SYS1EIL TO COATS OF S7I MI PLUS MEW MULL A VIAll. COWING WIN SURE-COMP IDENTIFIES NEW DECOR ITEM OR FINISH. SEE INTERIOR FINISH SCHEDULE, SHEET 04.0 FOR CONTRACTOR SCOPE INDICATES DOOR PER SCHEDULE NON-ENERGIZED r te' DECORATIVE TRACK PER SCH ED. 1 CnnP rDMPLIANcE I ry .f E r. ErL./ r JP t -I / 11 ' Ct./ Of T uk.vila Pi m - 'iT'c ir r ?C7f A I " CIP ANNUM P"L 0 I • .:,,A6.T+ivertiA 9330 BALBOA AVENUE SAN DIEGO, CA 92123 0 1999 Jade in the Box Inc. These drawings and specifications are the property of Jack in the Box Inc and shall not be copied or reproduced without its previous written consent. RELEASE: P.M.(JB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions M w. a1 a1 0 rn �i r\ In In �o I EalletE s 08/.2/2006 I site information MK TYPE: = ? JI B # i p :.- ADDRESS: - v 2 I^ p - .. . 1- K ' ... r. Q DRAIN BY: , 06. : - LE SCALE: 1/4' = 1'-0' FURNITURE II RCP PLANS, NOTES & SOW L IDI.O r f f • ;r • r L INSTALL (N) PARTITION PER FINISH SEE DETAIL 2/03.1 R _ • ■••••••••••••-••■■r K - mss .••••• w. r- •••••• - ► • • 59' MIN. ' (E) WATER CLOSET TO REMAIN SEES SHT. A2.0 ter REMOVE & RELOCATE (E) WATEi CLOSET (O.F.C.I.) SEE SHT. A2.0 FOR ADD'L INFO. REMOVE & REPLACE (E) STUD WALL FOR TOP AC BOTTOM CONN. SEE DETAILS, TYP. FOR ADD'L ;INFO. MEWS / 32' M IN. i i 1 3 . -0 . MIN. 4' MAX. U L 6 3/4 (E) �CAA ,VA I t 10 BE LOCATED 4' -4 1/4' ROOD* (E) ' -c :.R SEE 94T. A2.0 a CI ,;. 1W. fir= EMIM I � I / I / I ,' r -3' � i i Ili I w 1 ...J i (E) URINAL TO M*N. ENLARGED RESTROOM FLOOR PLAN INSTALL (N) PARTITION PER FINISH SCHEDULE, SEE DETAIL 2/103.1 REMOVE (E) WALL & DOOR 5' -0' (E) LAVATORY TO • i 1/2." - ,`-0r d9IE� 1) SEE SHT. A2.0 FOR ADD'L INFO. 2) G.C. TO RELOCATE SEWER ROUGH -IN, AS REVD., TO INSURE PROPER CLEARANCE TO PLUMBING FIXTURES. 3) G.C. TO INSTALL (N) CROME STANDOFFS, AS REQ'D., ON PLUMBING FIXTURES. i _ 'VESTIBULE • (E) WATER CLOSET TO REMAIN SEE SHT. A2.0 FOR ADO'L. WO. P } I O /EWING grafr4 MCA 10 REMAIN uNcHwICEn. SERVICE FLOORING GENERAL PLAN NOTES 1. INSTALL FLOORING AS PER MANUFACTURER'S INSTRUCTIONS. SEE DETAIL SHEETS FOR MORE INFORMATION ON TRANSITIONS AND BASE CONDITIONS. 2. FLOORING SHALL BE INSTALLED AS THERE IS NO POOLING OF UQUID. ANY SUCH CONDITIONS SHALL NOT BE ACCEPTED BY THE OWNER AND CORRECTION WILL BE REQUIRED. 3. REFER TO INTERIOR FINISH SCHEDULE FOR MORE INFORMATION. 4. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL QUANTITIES BEFORE ORDERING OR INSTALLING FLOORING MATERIAL. 5. ALL GROUT SHALL BE SEALED. 6. NOT USED. 7. REFER TO FLOORING LAYOUT AND FINISH SCHEDULE FOR SANITARY COVE BASE COLOR. 8. CONTRACTOR SHALL ORDER AND INSTALL FLOORING MATERIAL IN MANNER AS SHOWN HERE IN. 9. A MINIMUM 1% STOCK OF ALL TILE SIZES AND COLORS SHALL BE CONSIDERED ATTIC STOCK AND LEFT FOR OWNER AT UNIT LOCATION. 10. IT IS RESPONSIBILITY OF CONTRACTOR TO VALIDATE FLOOR TILE SQUARE FOOTAGE PRIOR TO ORDER MATERIAL. ! 1_1 I I I I Ii I I ii I I I .1 I ' I I __ I _ i I Li miti i am I tKa L j i I 111LE BASE AT prQ STAIN 94A\l BE C (N) owwsious s/ec' RADIUS uE COW ate. 21 Mt RN. soy Ti = 924 SQ.FT. T2 = 221 SQ.FT. T3 = 218 SQ.FT. (INCL 10X WASTE - SEE NOTE 10/ID1.1) PARTIAL FLOOR LAYOUT & FINISHES i 1 REV/EVJED FOR i CODE COMP; TAN 1 � 1 /4 ' = 1'-o MAY 3 0 200e City OfTtik - t; : 3 JfLU tw 9ftifiWiki r- to P1109 °will) Oft or susisu Wa• rq fCr' 'i�.`Gl © 1999 Jock in the Box Inc. These drawings and specifications are the property of Jock in the Box Inc and shall not be copied or reproduced without its previous written consent RELEASE: P.M.(JB ONLY): PERMIT: APR. 17, 2006 BID: CONS1RUCT1ON: 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z W cc I HESS: dates revisions C i MK TYPE: rA CUM DE PActT 1 fi v C a C0 01 c+ g 4r I trimEs JE 2 site information i► �?- - r L • ia AS MORD X M a' 00 et; r, v1 cc Co C ORAL! BY: _ FLOORING LAYOUT PLAN&ITES a ENL RR PLAN ID1.1 4 PL1 1 1880 1877 • M INTERIOR ELEVATION • ce 0 W 1881 INTERIOR ELEVATION INTERIOR ELEVATION 0 1 d u7 NTERIOR ELEVATION NTERIOR ELEVATION Nie ( v13) It: v► t: INTERIOR ELEVATION 11 110111131 • S VAC11 1246 FOR SANITARY COVE! FLOOR PLAN AND FIH INTERIOR ELEVATION INTERIOR ELEVATION FOR SIGN & DIB ION MASERS SEE OCT. �i e 'FOR TILE BASE FINISH REFER TO FLOOR PLAN AND FINISH SCHEDULE - TYPICAL OWNIC 3' -6' BASE FINISrI REFER TO SCHEDULE - TYPICAL i f • : FOR S TAR`i , rE 'ME BASE F HSH REFER TO ROOK PLAN ANC =ISSN SC?EIV-E - TYPICAL WPM NIL INTERIOR ELEVATION INTERIOR ELEVATION • NOTCH APRON AT BRACKETS, TYP. c S N INTERIOR ELEVATION e 1920 1921 INTERIOR ELEVATION ✓ L IAI S T VOIV3 INTERIOR ELEVATION IL NTERIOR ELEVATION r IMO PAIL V111203 \ —cr) l.. INTERIOR ELEVATION NOTE: FOR DISTRIBUTION NUMBERS & FOR RONSTAEIATION lFORMAT10N- REFER TO SHT A2-0 DETAILS • . INTERIOR ELEVATION INTERIOR ELEVATION - 4 u : 'AW FOR TILE BASE FINISH REFER TO FLOOR PLAN AND FINISH SCHEDULE - TYPICAL FQR I CODE CC7'%1PLIAfi :E p'9ir.rs — •r ,h .( c. C T_ c ..�, ; ;.j K'•': III ;I: Ip n'R I)T" "Tgr'l P610(414 » Io nrt a 1999 Jade in the Box Inc. These drawings and specifications Ore the property of Jock in the Box Inc and shall not be copied or reproduced without its previous written consent. /fH4 .(6r0 J�J ( _,f PAR 'ME 1`4 , 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z 0 >— J 1 ADORES& dates RELEASE: P.M.(JIB ONLY): PERMIT: APR. 17, 2006 BID: CONSTRUCTION: revisions Z .- k. 431 W el t 1 I o < r71 X Cr r3 V 471 . t o v ipp 'Q • ' o+ v, a l /3 g 00 00 > III° CI 0 u�iv co co • v Io in 1n C in r /� Cs a� :1 v+ CO CO E'er ae •..'MOs site information �\ TYPE: - J it :C Ir • _ I r Y sc 1/4• =1'-0" INTERIOR ELEVATiONS is MURALS ID2.0 ORAW4 BY: JEF .* • - 1 r f f • ;r • r L INSTALL (N) PARTITION PER FINISH SEE DETAIL 2/03.1 R _ • ■••••••••••••-••■■r K - mss .••••• w. r- •••••• - ► • • 59' MIN. ' (E) WATER CLOSET TO REMAIN SEES SHT. A2.0 ter REMOVE & RELOCATE (E) WATEi CLOSET (O.F.C.I.) SEE SHT. A2.0 FOR ADD'L INFO. REMOVE & REPLACE (E) STUD WALL FOR TOP AC BOTTOM CONN. SEE DETAILS, TYP. FOR ADD'L ;INFO. MEWS / 32' M IN. i i 1 3 . -0 . MIN. 4' MAX. U L 6 3/4 (E) �CAA ,VA I t 10 BE LOCATED 4' -4 1/4' ROOD* (E) ' -c :.R SEE 94T. A2.0 a CI ,;. 1W. fir= EMIM I � I / I / I ,' r -3' � i i Ili I w 1 ...J i (E) URINAL TO M*N. ENLARGED RESTROOM FLOOR PLAN INSTALL (N) PARTITION PER FINISH SCHEDULE, SEE DETAIL 2/103.1 REMOVE (E) WALL & DOOR 5' -0' (E) LAVATORY TO • i 1/2." - ,`-0r d9IE� 1) SEE SHT. A2.0 FOR ADD'L INFO. 2) G.C. TO RELOCATE SEWER ROUGH -IN, AS REVD., TO INSURE PROPER CLEARANCE TO PLUMBING FIXTURES. 3) G.C. TO INSTALL (N) CROME STANDOFFS, AS REQ'D., ON PLUMBING FIXTURES. i _ 'VESTIBULE • (E) WATER CLOSET TO REMAIN SEE SHT. A2.0 FOR ADO'L. WO. P } I O /EWING grafr4 MCA 10 REMAIN uNcHwICEn. SERVICE FLOORING GENERAL PLAN NOTES 1. INSTALL FLOORING AS PER MANUFACTURER'S INSTRUCTIONS. SEE DETAIL SHEETS FOR MORE INFORMATION ON TRANSITIONS AND BASE CONDITIONS. 2. FLOORING SHALL BE INSTALLED AS THERE IS NO POOLING OF UQUID. ANY SUCH CONDITIONS SHALL NOT BE ACCEPTED BY THE OWNER AND CORRECTION WILL BE REQUIRED. 3. REFER TO INTERIOR FINISH SCHEDULE FOR MORE INFORMATION. 4. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL QUANTITIES BEFORE ORDERING OR INSTALLING FLOORING MATERIAL. 5. ALL GROUT SHALL BE SEALED. 6. NOT USED. 7. REFER TO FLOORING LAYOUT AND FINISH SCHEDULE FOR SANITARY COVE BASE COLOR. 8. CONTRACTOR SHALL ORDER AND INSTALL FLOORING MATERIAL IN MANNER AS SHOWN HERE IN. 9. A MINIMUM 1% STOCK OF ALL TILE SIZES AND COLORS SHALL BE CONSIDERED ATTIC STOCK AND LEFT FOR OWNER AT UNIT LOCATION. 10. IT IS RESPONSIBILITY OF CONTRACTOR TO VALIDATE FLOOR TILE SQUARE FOOTAGE PRIOR TO ORDER MATERIAL. ! 1_1 I I I I Ii I I ii I I I .1 I ' I I __ I _ i I Li miti i am I tKa L j i I 111LE BASE AT prQ STAIN 94A\l BE C (N) owwsious s/ec' RADIUS uE COW ate. 21 Mt RN. soy Ti = 924 SQ.FT. T2 = 221 SQ.FT. T3 = 218 SQ.FT. (INCL 10X WASTE - SEE NOTE 10/ID1.1) PARTIAL FLOOR LAYOUT & FINISHES i 1 REV/EVJED FOR i CODE COMP; TAN 1 � 1 /4 ' = 1'-o MAY 3 0 200e City OfTtik - t; : 3 JfLU tw 9ftifiWiki r- to P1109 °will) Oft or susisu Wa• rq fCr' 'i�.`Gl © 1999 Jock in the Box Inc. These drawings and specifications are the property of Jock in the Box Inc and shall not be copied or reproduced without its previous written consent RELEASE: P.M.(JB ONLY): PERMIT: APR. 17, 2006 BID: CONS1RUCT1ON: 9330 BALBOA AVENUE SAN DIEGO, CA 92123 Z W cc I HESS: dates revisions C i MK TYPE: rA CUM DE PActT 1 fi v C a C0 01 c+ g 4r I trimEs JE 2 site information i► �?- - r L • ia AS MORD X M a' 00 et; r, v1 cc Co C ORAL! BY: _ FLOORING LAYOUT PLAN&ITES a ENL RR PLAN ID1.1 4