Loading...
HomeMy WebLinkAboutPermit PG06-168 - JONES RESIDENCEJONES RESIDENCE 13039 56 AV S PG06 -168 Parcel No.: Address: Suite No: City of Tt.rwila Steven M.t, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: citukwila.wa.us 2172000050 13039 56 AV S TUKW Steve Lancaster, Director PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG06 -168 09/27/2006 03/26/2007 Tenant: Name: Address: JONES RESIDENCE 13039 56 AV S, TUKWILA WA Owner: Name: JONES THOMAS A Address: 13039 56TH AVE S, TUKWILA WA Contact Person: Name: BRENNAN HEATING & NC Address: 4601 S 134 PL, TUKWILA WA Contractor: Name: BRENNAN HEATING & A/C LLC Address: 2725 152ND AV NE, REDMOND WA Contractor License No: BRENNHA971 R9 Phone: Phone: 206 248 -7900 Phone: 206 248 -7900 Expiration Date: 12/29/2007 DESCRIPTION OF WORK: REPLACE AND RELOCATE HOT WATER HEATER. GAS PIPING TO FURNACE, HWT, RANGE, FIREPLACE, DRYER, AND BBQ. Value of Plumbing /Gas Piping: $0.00 Fees Collected: $183.00 Uniform Plumbing Code Edition: 2003 International Fuel Gas Code Edition: 2003 FIXTURE TYPE AND QUANTITY Plumbing Bathtub or combination bath /shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with Independent drain.. Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 0 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and /or water 0 treatment equipment 0 0 Medical gas piping system serving one to five 0 inlets /outlets for a specific gas 0 0 Gas Piping Gas piping outlets (0 -5) 5 Gas piping outlets (6 +) 1 **continued on next page** doc: UPC - Permit PGO6 -168 Printed: 09-27 -2006 City of Ttasswila Steven M. %taviet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ettukwila.wa.us Steve Lancaster, Director Permit Number: PGO6 -168 Issue Date: 09/27/2006 Permit Expires On: 03/26/2007 Permit Center Authorized Signaturq: I hereby certify that I have read an ex ordinances governing this work will b Date: 01 (% r his permit and know the same to be true and correct. All provisions of law and with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performanc of work. I am authorized to sign and obtain this plumbing/gas piping permit. Signature: Print Name: b3k IP-ARLAilat Date: of l9- `7164, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC - Permit PG06 -168 Printed: 09 -27 -2006 CiTV Ttir0, '0A DEPT. CF C^ f1' C.:v: LC; A.. M 63;2 U':iI d GtCLVD. TUKWILA, WA 93188 Parcel No.: 2172000050 Address: 13039 56 AV S TUKW Suite No: Tenant: JONES RESIDENCE bst pFr PERMIT CONDITIONS ”IT rFFITFR Permit Number: PGO6 -168 Status: ISSUED Applied Date: 09/2712006 Issue Date: 09/27/2006 1: "'PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted In the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve Inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. **continued on next page** doc: Conditions PG06 -168 Printed: 09 -27 -2006 DEPT. C7 i C_...;,, ?..:.VT tits 6300 SLLI- 11k,L.N iLk LLVD. TUKWILA, WA 98188 1 hereby certify that I have read these conditions and will comply with them governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or regulating construction or the performance of work. Signature: Print Name: DZ Q � 7)1440 iLlSserd, n 1 PERMIT CENTER as outlined. All provisions of law and ordinances cancel the provision of any other work or local laws Date: 9.. /D--i jtt#p doc: Conditions PG06 -168 Printed: 09 -27 -2006 Noe CITY OF TUKWILA Community Development Department Public Works Department Permit Center 8300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** /� King Co Assessor's Tax No.: a l'li&OO OOS 0 Site Address: 1 3[ 39 54-ru Ayr P Suite Number: Tenant Name: JoKies New Tenant: Property Owners Name: AL.IDY >< •14ET(A JJ J Ol.IC 6 Mailing Address: 13031 Me-r“ RUC ru A C TUI`411t-/� city Floor. ❑ Yes D..No Lat; 9gl'Z$ State Zip Day Telephone: e. a q i>o Mailing Address: 5440 I S [ . ^[u V 1j li71 % OL t la c, ZZipp E -Mail Address: Fax Number: 01O(- ari • Zeic\ }■,TMC,TO. FARMAlf CFN iMeehan #cat Confractorinformat�o odsbis � tic.., L ., s, �ti 'i� •.. mt.ew. ,. .. 1. -.. _ �.- �W+a �,�z; "p`b„�., :.�•'rn Company Name: I EKIk1l l t--1 EA-(10 cv ()LA ito . Mailing Address: 4(0 61 C I St--• "n+ -1. -T-0MM 63 11'-A OA q k-ta o 4 , /� 1 City State Zip 8 Contact Person: -lAb3 t Allgi& 1 Day Telephone: ,t.0%n E-Mail Address: Fax Number: p2� l cl Contractor Registration Number gI�I►�i A Y17 (IRS( Expiration Date: Lai 31 /C"- "An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance " ARCHITECT( Company Name: Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number: State Zip ENCrER QFeiEG(�RI} All plans grust perek stamped bytnglner of Reo Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip y:\tpamitt plmVec ehenae&penoit npplic W on (7.20P1) Reviled: 6841 bh Page 1 PLUMBING AND GAS PIPING CONTRe,TOR INFORMATION Company Name: f 7. I I1 A -1 4pA-ri Kilt ii it k. R" Mailing Address: 4(oe( S' 154 rs TL l )Kk�iiM °altar car A State r+D Contact Person: S A laktFA&t 4WE&L Day Telephone: c Nr e3.4 2' -"MOD E-Mail Address: Fax Number: d • ag- E • `7 0I t c Contractor Registration Number: &2EMMWil.q, ife,i9 Expiration Date: 1 011 4 41 1 0 Valuation of Plumbing work (contractor's bid price): S d6 . , ga' 1 -O° Valuation of Gas Piping work (contractor's bid price): S' Scope of Work (please provide detailed information): . 19 VLACC kr-A�woA I�ISF Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: W VrivaonsWomu- Appliwioo. On UiwV -200 a - Penult Applic.rirn.doc Revised: 9-20a6 W Page 5 of 6 $t#ureirThe Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain - Gas piping outlets (1, Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per -, drain (inside building) Water heater and/or vent 1 Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Q: W VrivaonsWomu- Appliwioo. On UiwV -200 a - Penult Applic.rirn.doc Revised: 9-20a6 W Page 5 of 6 MECHANICAL CONTRACTOR INFO TION f Company Name: 2)R niklikt r.At thief It A lit. Mailing Address: o'Y 4p01 S 13 -n n _ - 1-0K6N14; IAA 9. t. fto ray State Zip �] Contact Person: -tAl ti-Cfird A1a at Day Telephone-) tai n • %Cf bb E -Mail Address: Fax Number: ra L to • Mi. - .19 OS Contractor Registration NumbeE?)IQelsa1U 14 ATJ L Rat Expiration Date: L � % 3l ics- "An original or notarized copy of current Washington State Contractor License ymust be presented at e time of permit issuances Valuation of Project (contractor's bid price): $ �A.1. • V 0 pWO -C;t7 Scope of Work (please provide detailed information):''F j 2 PLAC. Glitc FOAJ.JA U% K I-LOT . IMS-rALL COSTouteAS Fi2EP1ACg imseri r PTAS "PePiklAr FtnM JttE;Tc'Tb F0101 ) 1-ItOP,13A4 Fig€PLAcE Zbatra irtB% • -VEz .DCA'° -C Et, S 7I&t6t "but accul__ RI 6ASEm t-r, Jj Residential: New... Replacement....❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gasp Other: Indicate type of mechanical work being installed and the quantity below: ITnjt:TXRe• =Qty ,UnitTypi: Qt' Unit Type:= " Qty ' - Boileribompressori, Fumace<100K BTU ! Air Handling Unit >10,000 CFM Fire Damper - 0 -3 HP /100,000 BTU Fumace>I00K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Fumace Ventilation Fan Connected to Single Duct Thermostat 1 15 -30 HP /1,000,000 BTU Mounted Heater Mounted Heater Ventilation System Wood/Gas Stove 30 -50 . • 750 000 BTU `/ G Appliance Vent Hood and Duct Water Heater 505- HP /1,750,000 BTU Repair or Addition to Heat/Retrig/Cooling System Incinerator - Domestic Emergency Generator �t ^ g -p (PC �T+ Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Other Mechanical Equipment RMEx% PPEICA` IO OTE Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by imitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 OR AUTHORIENT: Signature: Print Name: Ls)IJ.EQT1 Alta( Mailing Address: 440I e, 1' Than- LEA a►g�Sl City - stab Zip Date: L11.'t -i / Day Telephone: abr.,- o2s,L2 • '74Ob Date Application Accepted: 0 _ f 211 Date Application Expires: _ _ r _ tiEk Staff Initials. q:\pannia plw'a chaeseaVumil application (7-2004) Revised: 6445 bb Page 4 SET RECEIPT RECEIPT NO: R06 -01523 Initials: JEM Payment Date: 09/27/2006 User ID: 1165 Total Payment: 386.22 Payee: SHAWNEAN ALLEN SET ID: 0927 SET NAME: BRENNAN SET TRANSACTIONS: Set Member Amount M06 -212 PG06 -168 TOTAL: 203.22 183.00 386.22 TRANSACTION LIST: Type Method Description Amount Payment Check 946 386.22 TOTAL: 386.22 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - RES MECHANICAL - RES PLUMBING - RES 000/322.100 95.00 000/322.100 203.22 000/322.100 88.00 TOTAL: 386.22 0177 09/27 9716 TOTAL 386.22 INSPECTION NO. Ir4SPECTION RECORD k Retain a copy with permit ir or go PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 36X0 Project: ex - - Re,. 2 Type of Ins ection: A"Qi/ Ad ITs: 'b %Lc Date Called: eciaTInstructions: Date Want d: /ZyX -7 a.m. Requester: Phone No: proved per applicable codes. D Corrections required prior to approval. I OMMENTS: rGi $58.00 REINSP ON FEE REQUIRED. Prior to inspection, fee must be paid at 6300 uthcenter Blvd., Suite 100. Call to sechedule reinspection. Date: Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit I Roe: iee INSPECTION NO. PE T CITY OF TUKWILA BUILDING DIVISION 6300 SQuthcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36(0 Proj am ('yl1E S V�[°� Type o nspectioLn: GUq h- re., //'` � ` C'r s Ad ress: 13035 5Gav Date Called: Special Instructions: Date Wanted: q—.25"--d C. Requester Phone as C ag - ?S u - -147Cp`proved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Date_ L5 _d 8.00 REINSPECTIOR FEE REQUITED. Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. IRe eipt No.: Date: 4.V•11 Vl/ a %llllllaI nJs, 1MN l` "al 11 11LL111UG1 L1GGl1DG UGLa11 r4LYUG 1 U1 L Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License BRENNHA97IR9 Licensee Name BRENNAN HEATING & A/C LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602346866 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 2725 152ND AVE NE Address 2 City REDMOND County KING State WA Zip 98052 Phone 2062487900 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/29/2003 Expiration Date 12/29/2007 Suspend Date Separation Date Parent Company Previous License FLOORSLOI2JL Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ERDAHL, DARRIN PARTNER/MEMBER 12/29/2003 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 FEDERATED MUTUAL INS CO 9127230 12/22/2004 Until Cancelled 512,000.00 11/04/2004 AMERICAN https: // fortress .wa.gov /Ini/bbip /printer.aspx ?License= BRENNHA971R9 09/27/2006