HomeMy WebLinkAboutPermit PG06-193 - FOSTER APARTMENTSFOSTER APARTMENTS
13533 52 AV S
EXPIRED 04 -18 -07
PG06 -193
Parcel No.:
Address:
Suite No:
City of Ttaewila
Steven M. nit, Mayor
DepaHment of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: ctlukwila.wa.us
0003000023
13533 52 AV S TUKW
Steve Lancaster, Director
PLUMBING /GAS PIPING PERMIT
Permit Number:
Issue Date:
Permit Expires On:
PGO6 -193
10/18/2006
04/16/2007
Tenant:
Name: FOSTER APARTMENTS
Address: 13533 52 AV S, TUKW ILA WA
Owner:
Name: APPLE LARRY J +ANN
Address: 491 LAKE LOUISE DR SW, LAKEWOOD WA
Contact Person:
Name: SHAWNEAN ALLEN
Address: 4601 S 134 PL, TUKWILA WA
Contractor:
Name: BRENNAN HEATING & A/C LLC
Address: 2725 152ND AV NE, REDMOND WA
Contractor License No: BRENNHA971R9
Phone:
Phone: 206 248 -7900
Phone: 206 248 -7900
Expiration Date: 12/29/2007
DESCRIPTION OF WORK:
BACKFLOW PREVENTER AND (1) GAS OUTLET FOR INSTALLATION OF GAS BOILER
Value of Plumbing /Gas Piping: $0.00
Fees Collected: $176.00
Uniform Plumbing Code Edition: 2003
International Fuel Gas Code Edition: 2003
FIXTURE TYPE AND QUANTITY
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain..
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste 0
Sinks 0
Urinals 0
Water Closet 0
Plumbina (cont.)
O Building sewer and each trailer park sewer 0
O Rain water system - per drain (inside bldg) 0
0 Water heater and /or vent 0
O Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and /or water
O treatment equipment 1
O Medical gas piping system serving one to five
0 inlets /outlets for a specific gas 0
0
Gas Piping
Gas piping outlets (0 -5) 1
Gas piping outlets (6 +) 0
"continued on next page**
doc: UPC - Permit
PGO6 -193 Printed: 10-18 -2006
City of Ttwi1a
Steven M. nss* t, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite 10100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ri.tukwila.wa.as
Steve Lancaster, Director
Permit Number: PG06 -193
Issue Date: 10/18/2006
Permit Expires On: 04/16/2007
Permit Center Authorized Signature:
Date: /0/ /P /0 6
1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances goveming this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the perfo nce of work. I am authorized to sign and obtain this plumbing /gas piping permit.
Signature: t, d_. Date: tot t w /oce
Print Name: St'tgt.JNJ A4
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
doc: UPC - Permit
PG06 -193 Printed: 10-18 -2006
PERMIT CENTER
PERMIT CONDITIONS
DE L _ :.:VT
6 C v ,Ulf,v..IJ�L`i LLiO.
TUKWILA, WA 93188
Parcel No.: 0003000023 Permit Number: PGO6 -193
Address: 13533 52 AV S TUKW Status: ISSUED
Suite No: Applied Date: 10/18/2006
Tenant: FOSTER APARTMENTS Issue Date: 10/18/2006
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the Job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Conditions
PG06 -193 Printed: 10-18-2006
PERMIT CENTER
I hereby certify that I have read these conditions and will comply with them
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or
regulating construction or the performance of work.
Signature:
Print Name:
b-winiCe)
am/Aloe/11\i ikt at,
Li'9 VM 'VlM.1 >lill
'OL.U3
as outlined. All provisions of law and ordinances
cancel the provision of any other work or local laws
Date: t °11$1 c7So
doc: Conditions P006 -193 Printed: 10-18 -2006
%a I 1 VI 1 • • •-•-•
Community Developmeilyeepartment
Pen-nit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
' PIumbing/GYennit No.
-Pre,Tect' No:"
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print"
1.:srrE 1,0C4T4ON:,:.
Site Address:
135-53 5-cakic. At6 5
Tenant Name:
King Co Assessor's Tax No.: D00300 00,a3
Suite Number: Floor:
New Tenant: 0--. Yes 0 -No
Property Owners Name: LARRY APPLC / re) ST elQ t1/41 LLC.
Mailing Address: SAM%
City
State
Zip
[CONTACT ?PERSON
-Who (1-6 eontsMt wlten your permit is 'ea-dile be issued,
Name: SWAW»JCA7J A-t Lr
Mailing Address: Lito0 E I 34 -rt, .17
Day Telephone: ab(o-
-17 )1(01
City State
E-Mail Address: Fax Number:
Zip
Company Name: tkourdikt4 Me-Ant-16c ti Ai C,
Mailing Address: 41001 S 134-at TL TbKLLA OA g (Og
City State Zip
Day Telephone: cap (er aLt 2- -7 (WO
Fax Number: erckbec - 4
Expiration Date: t .L/ea-1 /07
Contact Person: SHAtia■IR ANI PI tint
E-Mail Address:
Contractor Registration Number. 13 Kehl 1.11-1Aci '7 HMI
Company Name:
Mailing Address:
Contact Person:
E-Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
ENGINEERORRECORD ; Alt piano mast be wet stamped bi Engineer of
Company Name:
Mailing Address:
Contact Person:
E-Mail Address:
QAApplicadondFams-Appliestione On LineO-2006 Plumbing-Gss Piping Pernik Application.doc
Revised: 4-2006
bb
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 2
Valuation of Project (contractor's bid price): S o� J t%0'
Scope of Work (please provide detailed information):
'BACKFLoLO-Pizcvl=►.ti'FR / 1 GAS airrc "
FOR IM kt.-LA'TIcD1d be C--A6 3x11 Z
Building Use (per Int'I Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
ts&fe YBe.
t ry T
fixture T'Ype -
/Piztura Tyke ..
';Qty `
"Fixture. type
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
,
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW
Signature:
R OR AUTHORIZGENT:
041,4t4_ Ota
Print Name: Je /Vh-L AU-CA I
Mailing Address: 4(O I 6 134 Th T' L
Date: I L iS iego
Day Telephone: &Olo - at} g •pct DO
It�IGDJIIfi ge1478
City State Zip
Date Application Accepted: 10 I �� I
Date Application Expires: Ott 11$ I I-
Staff Initials
Q:Nppliwionnwozmn- Applications On Line- 2006 - Plumbing-Gas Piping Penni Appliwion.doc
Revised: 4-2006
bb
Page 2 of 2
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
RECEIPT
Parcel No.: 0003000023
Address: 13533 52 AV S TUKW
Suite No:
Applicant: FOSTER APARTMENTS
Permit Number: PGO6 -193
Status: APPROVED
Applied Date: 10/18/2006
Issue Date:
Receipt No.: R06 -01665 Payment Amount: 176.00
Initials: LAW Payment Date: 10/18/2006 01:57 PM
User ID: 1632 Balance: 50.00
Payee: BRENNAN HEATING & AIR CONDITIONING LLC
TRANSACTION LIST:
Type Method Description
Amount
Payment Check 17487 176.00
ACCOUNT ITEM LIST:
Description
Current Prate
Account Code
GAS - RES
PLUMBING - RES
000/322.100 88.00
000/322.100 88.00
Total: 176.00
0850 10/18 9716 TOTAL 367.18
doc: Receipt Printed: 10 -18 -2006
INSP ION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain p copy with permit
PE
IT NO.
6)431 -3670
Project:
A /s.. ..G
Type of ns sec ion: ,
��.a_ a._ .
._
Addy- ss:
)35'33 -S7 A. C
Date Called:
Special Instructions: /�
KF-C� /9/i
Date Wanted
Ir
Requester:
Phone No
AC Approved per applicable codes.
MENTS:
Inspector:
Corrections required prior to approval.
t IDatet 71
0 $58. kEINSPECTIONTEE EQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
(Receipt No.:
Date:
03 -01 -2007
SHAWNEAN ALLEN
4601 S 134 PL
TUKWILA WA 98168
City of Tukwila Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
RE: Permit No. PG06 -193
13533 52 AV S TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the Uniform Plumbing Code and/or International Fuel Gas Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Plumbing and/or Gas Code does allow the Building Official to approve one extension of time for an
additional period not exceeding 180 days. Extension requests must be in writine and provide satisfactory reasons why circumstances
beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 04 /18/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
XC:
Permit File No. PG06 -193
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665
A. ubv a vi c
NINd
Washington State Department of Labor and Industries
General/Spectalty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must mamtain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
BRENNHA971R9
Licensee Name
BRENNAN HEATING & A/C LLC
Licensee Type
CONSTRUCTION CONTRACTOR
11111
602346866
Ind. Ins. Account Id
Business Type
LIMITED LIABILITY COMPANY
Address 1
2725 152ND AVE NE
Address 2
City
REDMOND
County
KING
State
WA
Zip
98052
Phone
2062487900
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
12/29/2003
Expiration Date
12/29/2007
Suspend Date
Separation Date
Parent Company
Previous License
FLOORSLOI2JL
Next License
Associated Lkense
Business Owner Information
Name
Role
Effective Date
Expiration Date
ERDAHL, DARRIN
PARTNER/MEMBER
12/29/2003
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
112
FEDERATED
MUTUAL
INS CO
9127230
12/22/2004
Until
Cancelled
$12,000.00
11/04/2004
AMERICAN