Loading...
HomeMy WebLinkAboutPermit EL09-0101 - VERIZON BUSINESSVERIZON BUSINESS 12682 GATEWAY DR ELO9-01O1 Parcel No.: 2716000020 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: 12682 GATEWAY DR TUKW VERIZON BUSINESS 12682 GATEWAY DR , TUKWILA WA Citylif Tukwila RREEF AMERICA REIT II CORP/ PO BOX 4900 #207 , SCOTTSDALE AZ K. CRAIG MANAWES, PE ONE VILLAGE DR, STE 500 , ABILENE TX Contractor: Name: BEST TECH INC Address: 17324 270 AVE SE , ISSAQUAH WA Contractor License No: BESTTI *002R7 DESCRIPTION OF WORK: RELOCATING EXISTING RECEPTACLES, LIGHT FIXTURES, AND INSTALLATION OF NEW EXIT LIGHTS AS REQUIRED FOR INTERIOR BUILDOUT OF TELECOMMUNICATION EQUIPMENT ROOM. INCLUDES INSTALLATION OF CIRCUITS FOR NEW AND RELOCATED CRAC UNITS, CHILLED WATER PUMP, AND CHILLER. INCLUDES INSTALLATION OF NEW PANEL BOARDS AND CIRCUITS TO SERVE NEW POWER DISTRIBUTION UNITS, CABLE LADDER SYSTEM, dc POWER PLANT, 500KVA UPS. Value of Electrical: NRES: $700,000.00 RES: $0.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Signature: Print Name: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT doc: EL -4/07 EL09 -0101 Fees Collected: Permit Number: Issue Date: Permit Expires On: Phone: Phone: 325 695 -1090 Phone: 425 - 985 -6284 Expiration Date: 12/27/2010 National Electrical Code Edition: EL09 -0101 04/29/2009 10/26/2009 Date: $8,916.25 2005 Date: -\ -D- I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the •erf of work. I am authorized to sign and obtain this electrical permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended Printed: 04 -29 -2009 or abandoned for a period of 180 days from last inspection. doc: EL -4/07 • EL09 -0101 Printed: 04 -29 -2009 Parcel No.: 2716000020 Address: Suite No: Tenant: 1: ** *ELECTRICAL * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.n'a.us 12682 GATEWAY DR TUKW VERIZON BUSINESS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL09 -0101 ISSUED 02/05/2009 04/29/2009 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -Elec Date: 4 ( z.. 1 O1 EL09 -0101 Printed: 04 -29 -2009 SITE LOCATION CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://Www.ci.tukwila.wa.us Site Address: 12682 Gateway Drive South Tenant Name: VERIZON Business Mailing Address: PO Box 4900 #207 Name: K. Craig Manawes, PE Mailing Address: One Village Drive, Suite 500 E -Mail Address: craig.manawes @wta- inc.com Will service be altered? ❑ Yes 12] No H.'Applications\ Forms - Applications On Line) -2009 - Electrical Permit Application doc bh • • Electrical Permit No. 001 ' 0 0 t Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 271600 -0070 Suite Number: Floor: 1 New Tenant: ❑ Yes ..No Property Owners Name: RREEF America REIT II Corporation Scottsdale City AZ 85261 State CONTACT PERSON - Who do we contact when your permit is ready to be issued Day Telephone: (325) 695 -1090 Abilene TX 79606 City Fax Number: State (325) 695 -3757 ELECTRICAL CONTRACTOR INFORMATION Company Namc: TBD Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Valuation of Project (contractor's bid price): $ 700,000 Scope of Work (please provide detailed information): Includes relocating existing receptacles, light fixtures, and installation of new exit lights as required for interior build out of telecommunication equipment room. Includes Zip Zip Zip installation of circuits for new and relocated CRAC units, chilled water pump, and chiller. Includes installation of new panel boards and circuits to serve new power distribution units, cable ladder system, DC power plant, 500KVA UPS. Adding more than 50 amps? ® Yes ❑ No Type of Use: Telecommunications Equipment Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ® Seattle City Light Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $145.60 (including an attached garage) ❑ Garages, pools, spas and outbuildings $78.00 ca ❑ Low voltage systems (alarm, furnace thermostat) $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $57.00 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fec schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension o f time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: 7 0datercae. Signature: Print Name: K. Craig Manawe Day Telephone: (325) 695 -1090 Mailing Address: One Village Drive, Suite 500 I Date Application Accepted: /1) - -1 bN H:\Applications\Forms- Applications On \In6l -2009 - Electrical Permit Application. doc bh Fees are based on the valuation of the electrical contract. ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Date Application Expires: 0$ 1 a c 1 MULTI - FAMILY AND COMMERCIAL MISCELLANEOUS FEES Date: 02/02/2009 Abilene TX 79606 City State Zip Staff Initials: r , Page 2 of 2 Parcel No.: 2716000020 Address: 12682 GATEWAY DR TUKW Suite No: Applicant: VERIZON BUSINESS Receipt No.: R09 -00647 Initials: User ID: Payee: WER 1655 BEST TECH TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 083127 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT 7,133.00 Account Code Current Pmts 000.322.101.00.0 7,133.00 Total: $7,133.00 Permit Number: EL09 -0101 Status: APPROVED Applied Date: 02/05/2009 Issue Date: Payment Amount: $7,133.00 Payment Date: 04/29/2009 10:01 AM Balance: $0.00 PAY ENT RECEVED doc: Receiot -06 Printed: 04 -29 -2009 Copy Reprinted on 02 -05 -2009 at 11:05:20 02/05/2009 RECEIPT NO: R09 -00202 Payment Date: 02/05/2009 User ID: 1165 Total Payment: 8,653.42 Initials: JEM Payee: WTA, INC. SET ID: S000001171 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D09 -015 EL09 -0101 M09 -013 TOTAL: 6,220.37 1,783.25 649.80 6,220.37 TRANSACTION LIST: Type Method Description Amount Payment Check 8629 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES • • City of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT TOTAL: 8,653.42 8,653.42 Account Code Current Pmts 000.345.832.00.0 1,783.25 000/345.830 6,870.17 TOTAL: 8,653.42 P AYMENT RECEIVED Project: VepoZONI ISIS . Type of Inspection: 2/00 Address: l Date Called: Special Instructions: Date Wanted: c 25- a.m Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPEQTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 a vl .. o1o 1 RMIT NO. (206)431 -3670 /2 COMMENTS: 0g Approved per applicable codes. Corrections required prior to approval. /Q Inspector: 1 El $60.00 REINSP CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: .k. i7o / &i54J h Type of Inspection: Address: t 2a2- Date Called: .--, Special Instructions: Date Wanted: Or' c .m Requester: Phone No: &1 IN ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: OK rd4v INSPECTION RECORD Retain a copy with permit ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: Project: Ml 1 , J C 7 Type of Inspection: Address: ! Date Called: Special Instructions: Date Wanted: 05 O 4r. Requester: Phone No: i INSPECTION RECORD Retain a copy with permit CLO-bi01 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20$)431 -3670 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: - IN Inspector: Date: 0 5 / 01 7 0 / LI $60.00 REINSP CTION FEE REQ,IIRED. Prior to inspection, feb must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: , ', . - Project Info Project Address 12682 Gateway Drive South Date 2/3/2009 Tukwila, Washington 98168 For Building Department Use Applicant Name: K. Craig Manawea Applicant Address: One village Drive, Suite 500, Abilene, Texas 79606 Applicant Phone: 325 - 695 -1090 2006 Was , ington State Nonresidential Energy Code Comp!' nce Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 OSIA PP,,A, A,P!Le copy C ODE IEINED FOR COMPLIANCE NFPA 70 - NEC ' --' - - Luui Oty Tukwilj B UILDING DIVISI0. RECE crr OF TU N LA FEB 0.5 2009 PERMIT CEO *6 - 0101 Project Info Project Address 12682 Gateway Drive South Date 2/3/2009 Tukwila, Washington 98168 For Building Department Use Applicant Name: K. Craig Manawes ApplicantAddress: one Village Drive, Suite 500, Abilene, Texas 79606 Applicant Phone: 325 -695 -1090 Project Description ❑ Plans Induded requirements. ❑ New Building ❑ Addition -' Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box sec. 1132.3) I. No changes are being made to the lighting ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts cm Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft Allowed x Area ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2006 Washington State Nonresidential Energy Code Compl'ance Form Interior Lighting Sur; LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage Revised July 2007 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Watts Proposed Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the Tamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. Use' LPA` (Wlsf) Use' LPA`SW /sf) 1.0 Automotive fadlity 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retain retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hall'" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified `laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Q ualification Checklist Note: If occupancy type is "Other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b reflector ) P ) or louvers, c) 5-60 watt T -1, T -2, T -4, T -5, T-8 lamps, and d) hard-wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. Interior Lighting SuL , ,nary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -1 Unit Lighting Power Allowance (LPA 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three -quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (10 or # of items Allowed Watts x ft (or x If) Name: X. Craig Manawea Appl. Name One village Drive, Suite 500, Abilene, Texas 79606 Appl. Phonc325- 695 -1090 Project Description ❑ Plans Induded requirements. ❑ New ❑ Addition 4 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Name: X. Craig Manawea Appl. Name One village Drive, Suite 500, Abilene, Texas 79606 Appl. Phonc325- 695 -1090 Project Description ❑ Plans Induded requirements. ❑ New ❑ Addition 4 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Name: X. Craig Manawea Appl. Name One village Drive, Suite 500, Abilene, Texas 79606 Appl. Phonc325- 695 -1090 Project Description ❑ Plans Induded requirements. ❑ New ❑ Addition 4 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Name: X. Craig Manawea Appl. Name One village Drive, Suite 500, Abilene, Texas 79606 Appl. Phonc325- 695 -1090 Project Description ❑ Plans Induded requirements. ❑ New ❑ Addition 4 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Project Info Proj Addres. 12682 Gateway Drive South Date 2/3/2009 I For Building Department Use 1 Tukwila, Washington 98168 Name: X. Craig Manawea Appl. Name One village Drive, Suite 500, Abilene, Texas 79606 Appl. Phonc325- 695 -1090 Project Description ❑ Plans Induded requirements. ❑ New ❑ Addition 4 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ less than 60% of the fixtures new installed wattage not increased & soace use not chanaed. 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Comp' nce Form Exterior Lighting Su► .nary LTG EXT Tradable Maximum Allowed Lighting Wattage Tradable Proposed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage Proposed Watts may not exceed Allowed Watts for Category Total Allowed Watts Total Proposed Watts Revised July 2007 Use mfgr listed maximum input wattage. For fixtures with hard -w'red ballasts only, the default table in the NREC Technical Reference Manual may also be used. Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W /ft Building Grounds Walkways less than 10 feet wide 1.0 W/linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft Stairways 1.0 W /ft Building Entrances and Exits Main entries 30 W/linear foot of door width Other doors 20 W/linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft Outdoor Sales Open areas (including vehicle sales Lots) 0.5 W /ft Street frontage for vehicle sales lots in addition to "open area" allowance 20 W /linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 W /ft for each illuminated wall or surface or 5.0W /linear foot for each illuminated waIl or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W /ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restaurants 400W per drive - through Parking near 24 -hour retail entrances 800 W per main entry 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting SL, . 'mary (back) LTG -EXT 2008 Washington State Nonresidential Energy Code Canpllance Fortes TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 Lighting Power AIIo‘- lime Adjustments LTG ;LPA 2006 Washington State Nonresidential Energy Code Compliance Fonns 2006 Wa ington State Nonresidential Energy Code Come ' • nce Form Revised July 2007 Project Address 1 12682 Gateway Drive south !Date 2/3/2009 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft From Table 15 -1 based on exceptions listed in footnotes Lighting, Motor, and', 2006 Washington State Nonresidential Energy Code Compliance ; Forms ansformer Permit Plans. ,.,heckIist LTG ; Revised July 2007 Project Address 12682 Gateway Drive South 'Date 2/3/2009 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E -9 yes 1513.2 Area controls Maximum limit per switch E-8,E- 9,E-13 n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations . n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes .. ! 1514 JMax. watts (Indicate watts for each exit sign IE_8 ! LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 lElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency 1 ! • TRANSFORMERS (Section 1540) n.a. I 1540 !Transformers !Indicate size and efficiency 1 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energ Code Compliance Form Lighting, Motor, anc ransformer Permit Plan; ecklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Foims Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting In Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of tuming off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole 'means,of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is availaple or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off" feature, which tums off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP- 1- 2002). ACTIVITY NUMBER: EL09 -0101 DATE: 02 -05 -09 PROJECT NAME: VERIZON BUSINESS SITE ADDRESS: 12682 GATEWAY DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COP PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS 0 CORRECTIONS: Approved Approved with Conditions I I Not Approved (attach comments) U Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division Permit Coordinator Not Applicable No further Review Required DUE DATE: 03-09-09 n DUE DATE: 02 -09 -09 n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SD1320 12/27/2000 Until Cancelled 01/01/1980 $4,000.00 12/27/2000 Name Role Effective Date Expiration Date VANDEN BOS, BRYAN K 01/01/1980 VANDEN BOS, CHERYL A 01/01/1980 VANDEN BOS, BRYAN K AGENT 01/01/1980 Untitled Page Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name BEST TECH INC UBI No. 602062810 Phone 4259856284 Status ACTIVE Address 17324 270TH AVE SE License No. BESTTI *002R7 Suite /Apt. License Type ELECTRICAL CONTRACTOR City ISSAQUAH Effective Date 12/27/2000 State WA Expiration Date 12/27/2010 Zip 98027 Suspend Date County KING Specialty 1 GENERAL Business Type Corporation Specialty 2 UNUSED Parent Company MASTER ELECTRICIAN INFORMATION License VANDEBK971BH Name VANDEN BOS, BRYAN K Status ACTIVE Business Owner Information Bond Information https://fortress.wa.gov/lni/bbip/Detail.aspx • • Page 1 of 1 04/29/2009 DRAWING INDEX & STATUS LEGEND: ISSUE / REVISIONS 1 ISSUE / REVISIONS SHEET ISSUED FOR CONSTRUCTION 4 5 1 2 3 4 5 6 SHEET ISSUED FOR INFO. & COORDINATION I= SHEET VOIDED 01.05.09 - 95% REVIEW 01.15.09 - 100% CD 01.26.09 - ADD. NO. 1 02.02.09 - PERMIT SET REFERENCE C -1 SHEET NUMBER SHEET TITLE DRAWING ISSUE DATE A -0.1 MECHANICAL - PLUMBING - ELECTRICAL (CONTINUED) E -8 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - SOUTH 12.12.2008 A -1.0 SITE PLAN E -9 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - NORTH 12.12.2008 A -1.1 EGRESS PLAN E -10 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - POWER ROOM 12.12.2008 � ,t ' » A -2.0 PARTIAL DEMO E -11 ELECTRICAL ONE LINE DIAGRAM 12.12.2008 r , A -2.1 PARTIAL FLOOR PLAN E -12 UPS WIRING DIAGRAM AND FEEDER TABLE 12.12.2008 x • A -3.1 ARCHITECTURAL DETAILS E -13 ELECTRICAL PANEL SCHEDULES 12.12.2008" ,. ;,, A -4.1 DOOR AND FINISH SCHEDULE E -14 ELECTRICAL PANEL SCHEDULES 12.12.2008 MPE -1 MECHANICAL AND ELECTRICAL SYMBOL LEGEND 12.12.2008 ' 'a '� E -15 ELECTRICAL PANEL SCHEDULES 12.12.2008 MPE -2 MECHANICAL AND ELECTRICAL OVERALL FLOOR PLAN 12.12.200$, E -16 ELECTRICAL PANEL SCHEDULES 12.12.2008 E -17 ELECTRICAL DETAILS 12.12.2008 M -3 PARTIAL FIRST FLOOR PLAN - HVAC - SOUTH 12.12.2008 • E -18 FIRST FLOOR PLAN - ELECTRICAL GROUNDING 12.12.2008 M -4 PARTIAL FIRST FLOOR PLAN - HVAC - NORTH 12.12.2008 : E -19 GROUNDING SCHEMATIC 12.12.2008 M -5 PARTIAL FIRST FLOOR PLAN -MECHANICAL ROOMANDCHILH YARD 12.12.2008 , $ E -20 GROUNDING DETAILS 12.12.2008 ' - M -7 D.C. POWER DC -1 PARTIAL FIRST FLOOR PLAN - COMMUNICATION CABLE LADDER - SOUTH 12.12.2008 M -8 HVAC DETAILS AND SECTIONS DC -2 PARTIAL FIRST FLOOR PLAN - COMMUNICATION CABLE LADDER - NORTH 12.12.2008 k � 3 � �; �� , ;2r ;,v a3Yer M -9 HVAC SCHEDULES DC -3 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - SOUTH 12.12.2008 & ` DC -4 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - NORTH 12.12.2008 DC -5 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - POWER ROOM 12.12.2008 DC -6 PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUND - SOUTH 12.12.2008 P -3 PARTIAL FIRST FLOOR PLAN - PLUMBING - SOUTH DC -7 PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUND - NORTH 12.12.2008 • P -4 PARTIAL FIRST FLOOR PLAN - PLUMBING - NORTH DC -8 PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUND - POWER ROOM 12.12.2008 DC -9 -48V. D.C. ONE LINE DIAGRAM 12.12.2008 .r E -3 PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - SOUTH DC -10 UPS 480V. D.C. ONE LINE DIAGRAM AND BATTERY RACK DETAILS 12.12.2008 .;� y E -4 PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - NORTH 12.12.2008 FIRE PROTECTION FP-1 PARTIAL FIRST FLOOR PLAN - Fl REALARM AND SPRINKLER SYSTEM - SOUTH 12.12.200$ 7 i E -5 12.12.2008 . F P -2 PARTIAL FIRST FLOOR PLAN - FIREALARM AND SPRINKLER SYSTEM - NORTH 12.12.2008 • . y 12.12.2008 FP-3 PARTIAL FIRST FLOOR PLAN- FlREALARM - BELOW RAISED FLOOR- - NORTH 12.12.2008 P . 12.12.2008 „'• F P-4 PARTIAL FIRST FLOOR PLAN - FIREALARM - BELOW RAISED FLOOR - NORTH 12.12.2008 . ;t„ DRAWING INDEX & STATUS LEGEND: _ • • - SHEET ISSUED FOR CONSTRUCTION ISSUE / REVISIONS 1 2 3 4 5 6 r.:. SHEET ISSUED FOR INFO. & COORDINATION I V I SHEET VOIDED 01.05.09 - 95% REVIEW 01.15.09 - 100% CD 01.26.09 - ADD. NO. 1 02.02.09 - PERMIT SET SHEET NUMBER SHEET TITLE DRAWING ISSUE DATE REFERENCE C -1 COVER SHEET 1 12.12.2008 :I , :I I ' - ARCHITECTURAL A -0.1 ARCHITECTURAL SYMBOLS AND NOTES 12.12.2008 '; � A -1.0 SITE PLAN 12.12.2008 A -1.1 EGRESS PLAN 12.12.2008 A -2.0 PARTIAL DEMO 12.12.2008 A -2.1 PARTIAL FLOOR PLAN 12.12.2008 A -3.1 ARCHITECTURAL DETAILS 12.12.2008 N. '1 , ,. A -4.1 DOOR AND FINISH SCHEDULE 12.12.2008 MECHANICAL - PLUMBING - ELECTRICAL MPE -1 MECHANICAL AND ELECTRICAL SYMBOL LEGEND 12.12.2008 ' 'a '� if kir MPE -2 MECHANICAL AND ELECTRICAL OVERALL FLOOR PLAN 12.12.200$, M -3 PARTIAL FIRST FLOOR PLAN - HVAC - SOUTH 12.12.2008 • M -4 PARTIAL FIRST FLOOR PLAN - HVAC - NORTH 12.12.2008 : '' M -5 PARTIAL FIRST FLOOR PLAN -MECHANICAL ROOMANDCHILH YARD 12.12.2008 , $ M -6 CHILLED WATER PIPING SCHEMATIC 12.12.2008 ' - M -7 CHILLED WATER PIPING SCHEMATIC 12.12.2008 M -8 HVAC DETAILS AND SECTIONS 12.12.2008 M -9 HVAC SCHEDULES 12.12.2008 & ` P -3 PARTIAL FIRST FLOOR PLAN - PLUMBING - SOUTH 12.12.2008 P -4 PARTIAL FIRST FLOOR PLAN - PLUMBING - NORTH 12.12.2008 12.12.2008 E -3 PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - SOUTH 12.12.2008 E -4 PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - NORTH 12.12.2008 of ; E -5 PARTIAL FIRST FLOOR PLAN - POWER ROOM, ELECTRICAL 12.12.2008 . E -6 PARTIAL FIRST FLOOR RAN - BECIRICAL ROOM AND COURTYARD, ELECTRICAL 12.12.2008 E -7 PARTIAL FIRST FLOOR PLAN - CHII 1 FR YARD AND PUMP ROOM, ELECTRICAL 12.12.2008 „'• ' , AT veri on busine ----- ss EQUIPMENT ROOM BUILDOU 12682 GATEWAY DRIVE SOUTH TUKWILA, WASHINGTON SITE CODE: TYK A VERIZON BUSINESS - TECHNICAL FACILITIES OPERATION AND CONSTRUCTION 604 EAST HOAG STREET PO BOX 10 YACOLT, WA 98675 VERIZON BUSINESS SR, IMPLEMENTATION LISA H. DAVIE NGINEER A. DRAWINGS THE WORK OUTLINED IN THIS DOCUMENT SHALL BE PERFORMED IN ACCORDANCE WITH THE VERIZON BUSINESS STATEMENT OF WORK, AND AS INDICATED IN PROJECT DRAWINGS AND SPECIFICATIONS. B. GENERAL REQUIREMENTS 1. THE CONTRACTOR IS TO INSTALL THE EQUIPMENT BASED ON WORKING SHIFTS BETWEEN 8:00 a.m. TO 5 :00 p.m. ON WEEKDAYS EXCEPT WHERE SPECIFIED DIFFERENTLY BELOW. ALL HVAC AND ELECTRICAL HOT WORK HAS TO HAVE A VERIZON BUSINESS APPROVED METHOD OF PROCEDURE (MOP'S) BEFORE ANY WORK CAN TAKE PLACE. 2. ANY WORK REQUIRED OVER ACTIVE VERIZON BUSINESS SWITCH EQUIPMENT OR IN THE VERIZON BUSINESS POWER ROOM MUST BE ACCOMPLISHED BETWEEN 12:00 a.m. (MIDNIGHT) AND 6:00 a.m. AND MUST BE APPROVED BY THE SITE MANAGER AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF THE WORK. ALL ELECTRIC HOT WORK HAS TO HAVE A VERIZON BUSINESS APPROVED METHOD OF PROCEDURE (MOP'S) BEFORE ANY WORK CAN TAKE PLACE. ALL ELECTRICAL MOP HOT WORK SHALL BE PERFORMED WITH 1000 VOLT TOOLS. 3. THIS IS A TRAFFIC - CARRYING, REVENUE - PRODUCING FACILITY WHICH MUST BE FULLY FUNCTIONAL THROUGHOUT THE DURATION OF THIS PROJECT. THEREFORE, GREAT CARE MUST BE TAKEN WHILE WORKING INSIDE THE VERIZON BUSINESS COMPUTER AREA AND THE EQUIPMENT MUST BE PROTECTED FROM DUST AND DAMAGE AT ALL TIMES. 4. WORK TO BE ACCOMPLISHED ON THE EXTERIOR OF THE VERIZON BUSINESS LEASE SPACE MAY OCCUR DURING REGULAR BUSINESS HOURS, SEVEN DAYS PER WEEK. 5. ALL WORK WITHIN THE BUILDING MUST BE COMPLETED ON OR BEFORE CONTRACT DATE, INCLUDING DELIVERY OF THE UNITS, PIPING, SETTING, AND CONNECTING THE HVAC UNITS. SETTING AND RIGGING OF THE NEW LIEBERTS AND AIR COOLED CONDENSERS WILL BE BY THE MECHANICAL CONTRACTOR. 6. THE CONTRACTOR SHALL FURNISH A SCHEDULE OF ALL WORK ACTIVITIES WITHIN THE BID PROPOSAL. 7. THE CONTRACTOR SHALL NOTIFY THE VERIZON BUSINESS PROJECT ENGINEER OF ANY CHANGES TO THIS STATEMENT OF WORK WHICH MAY INCREASE THE AMOUNT OF THE CONTRACT. CONTRACTOR MUST OBTAIN APPROVAL FROM PROJECT ENGINEER PRIOR TO COMMENCEMENT OF ANY WORK NOT INCLUDED IN THE BASE BID. 8. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING WITH VERIZON BUSINESS MANAGEMENT FOR ACCESS TO THE BUILDING, FREIGHT ELEVATOR, SECURITY SYSTEMS, TURNING FIRE SUPPRESSION SYSTEM ON /OFF, DELIVERIES TO AND FROM THE BUILDING. UPON COMPLETION OF WORK EACH DAY, THE CONTRACTOR SHALL LEAVE AREAS OF CONSTRUCTION ACTIVITY, DUSTED AND BROOM CLEAN. CONTRACTOR PERSONNEL ARE TO USE EXTREME CARE WHEN USING SHOP VACUUM, INSURING FIRE SUPPRESSION IS DISABLED AND VACUUM DISCHARGE NOT DIRECTED AT ANY SMOKE DETECTORS. TRASH MUST BE REMOVED FROM BUILDING EACH DAY. 9. WHEN APPLICABLE, CONTRACTOR SHALL SCHEDULE ANY WORK DEEMED NOISY OR DISRUPTIVE TO VERIZON BUSINESS PERSONNEL OR SITE OPERATION WITH THE SITE MANAGER OR SUPERVISOR AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF ACTIVITIES. 10. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, TOOLS, EQUIPMENT AND SUPERVISION TO COMPLETE THE PROJECT WITHIN TIME FRAME SPECIFIED. 11. CONTRACTOR SHALL PROTECT WALLS, FLOOR AND ALL VERIZON BUSINESS PROPERTY FROM DAMAGE. IF DAMAGE OCCURS DURING CONSTRUCTION, CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING TO THE PREVIOUS CONDITION. 12. PROVIDE A SAFETY BARRIER OVER ANY EQUIPMENT IN THE WORK AREA, IF APPLICABLE, OVER SWITCH EQUIPMENT BAYS, TO PREVENT ANYTHING FROM FALLING ON OR INTO THE BAYS. PROVIDE PLYWOOD COVERS OVER THE BATTERIES IF WORK IS OVERHEAD, WITH PROPER VENTILATION. 13. CONTRACTOR SHALL PROVIDE FLOOR PROTECTION WITH 1/2" MASONITE BOARD FOR WORK AREAS AND DELIVERY PATH WHEN SETTING OF EQUIPMENT. CONTRACTOR SHALL PROVIDE FLOOR PROTECTION WITH 1/2" MASONITE BOARD FOR TRAVEL PATH TO AND FROM TOILET ROOMS AND DRINKING FOUNTAINS. 14 15 16 b. PROVIDE PROPER LABELS ON PIPING AS SPECIFIED. 1360,.. ° d WORKING CONDITIONS CONDENSATE DRAIN PIPING AND HUMIDIFIER MAKE -UP PIPING SHALL BE TYPE "L" COPPER WITH 15% SILFOS SILVER BRAZING JOIItT &. a. PROVIDE AND INSTALL PROPER INSULATION ON PIPING AS SPECIFIED. WORK IN HALON PROTECTED AREAS BEFORE WORK CAN BEGIN WITHIN THE FACILITY, THE CONTRACTOR SHALL FIRST DETERMINE THE IMPACT ON ANY HALON - PROTECTED AREA. IN MOST CASES, THE HALON SYSTEM SHALL BE DISARMED PRIOR TO COMMENCEMENT OF WORK. AT THE END OF EACH DAY, THE CONTRACTOR SHALL ALSO ENSURE THAT THE SYSTEM IS RETURNED TO NORMAL OPERATION. ALL HALON DUMPED AS A RESULT OF THE CONTRACTOR NOT FOLLOWING THIS DIRECTIVE WILL BE REPLACED BY THE CONTRACTOR AT THEIR EXPENSE. VERIZON BUSINESS WILL NOT PROVIDE HALON FOR THE CONTRACTOR'S USE IN RECHARGING THE SYSTEM. IN THE EVENT THAT DRILLING OR CUTTING IS REQUIRED IN HALON PROTECTED ZONES, THE CONTRACTOR SHALL COVER EVERY HALON SENSOR LOCATED WITHIN 50' OF THE EFFECTED AREA WHILE THE SYSTEM IS DISARMED. THIS WILL ENSURE THAT FOREIGN PARTICLES DO NOT BECOME LODGED IN THE SENSOR, THUS RENDERING THEM INEFFECTIVE OR CAUSING A FALSE ALARM. DRILLING AND CUTTING BEFORE BEGINNING ANY DRILLING OR CUTTING OF CONCRETE, GYPSUM BOARD, OR OTHER DUST- PRODUCING MATERIALS, THE VERIZON BUSINESS REPRESENTATIVE SHALL BE NOTIFIED SO THAT FIRE- PROTECTION SYSTEMS CAN BE DISARMED, AS NEEDED. WHEN DRILLING OR CUTTING IS REQUIRED IN AN AREA WHERE TELECOMMUNICATIONS EQUIPMENT INSTALLED, A HEPA VACUUM CLEANER SHALL BE EMPLOYED TO REMOVE THE DUST OR OTHER DEBRIS DURING THE OPERATION. ALL AREAS ABOVE THE CEILING OR UNDER THE RAISED FLOOR SHALL BE VACUUMED CLEAN AFTER THE WORK IS COMPLETE. ALL VACUUM CLEANERS SHALL BE APPROVED FOR USE BY RFEC AND FACILITY MANAGEMENT. WHEN WET CORING, ALL PRECAUTIONS SHALL BE TAKEN TO CONFINE WATER TO WORK AREA. ALL EQUIPMENT IN AFFECTED AREAS SHALL BE PROTECTED TO THE SATISFACTION OF THE VERIZON BUSINESS REPRESENTATIVE. ALL CORING LOCATIONS SHALL BE APPROVED BY VERIZON BUSINESS REPRESENTATIVE PRIOR TO BEGINNING THAT WORK. 17 WELDING AND OPEN FLAMES APPROVAL TO DO WELDING SHALL BE OBTAINED IN ADVANCE FROM THE VERIZON BUSINESS REPRESENTATIVE. NO WELDING SHALL OCCUR WITHIN 5' OF ANY FIXED EQUIPMENT WITHOUT PRIOR NOTIFICATION AND SAFEGUARDS DEEMED APPROPRIATE BY THE VERIZON BUSINESS REPRESENTATIVE. THE VERIZON BUSINESS REPRESENTATIVE WILL COORDINATE DISABLING LOCAL ZONING OF FIRE/HALON SUPPRESSION SYSTEMS AND NOTIFICATION OF SECURITY /SURVEILANCE. 18 CONTRACTOR SHALL PROVIDE AND MAINTAIN TRASH DUMPSTER FOR DISPOSAL OF CONSTRUCTION DEBRIS AND TRASH. TRASH DUMPSTER TO BE REMOVED AT COMPLETION OF PROJECT. C. "i/ERIZON BUSINESS FURNISHED CONTRACTOR INSTALLED LIEBERT CRAC UNITS 1. INSTALL NEW VERIZON BUSINESS FURNISHED LIEBERTS COMPLETE WITH LABOR AND MATERIALS. ELECTRICAL AND CRANE SERVICE, AS REQUIRED. NEW UNITS SHALL BE PIPED WITH HYDRONIC PIPING AS SPECIFIED. a. PROVIDE AND INSTALL PROPER INSULATION ON CHILLED WATER PIPING AND DRAIN LINE AS SPECIFIED. b. PROVIDE AND INSTALL NECESSARY SERVICE VALVES ON NEW LIEBERT UNITS AS INDICATED AND SPECIFIED. SEPARATE PERMIT REQUIRED FOR: BUILDING DIVISION PROJECT LOCATION 12682 GATEWAY DRIVE SOUTH TUKWILA, WASHINGTON 3. FOR DOWN FLOW RAISED FLOOR APPLICATION, PROVIDE RAISED FLOOR PANEL OR RIGID INSULATION IN GAP BEHIND UNIT STAND AND WALL. TO PREVENT SUPPLY AIR LEAKAGE. 4. FOR DOWN FLOW RAISED APPLICATION, PROVIDE PROPER CUT -OUT OF RAISED FLOOR AT UNIT STAND LOCATION. 5. PROVIDE PROPER LABELS ON PIPING, AS SPECIFIED. 6. COMPLETE ELECTRICAL INSTALLATION TO NEW LIEBERTS AND CONDENSER INCLUDING: a. PROVIDE START -UP CHECK LIST AND SUBMIT COPIES TO CONSTRUCTION SUPERVISOR. D. PROJECT CLOSE OUT 1. CONTRACTOR SHALL ADVISE PROJECT ENGI AND SCHEDULE PUNCH LIST WALK THROUGH 2. CONTRACTOR SHALL COMPLETE ALL PUNCH LIST WALK THROUGH. a. AC POWER SUPPLY WIRING, CONDUIT AND TERMINATIONS AS INDICATED AND SPECIFIED. b. ALL CONTROL WIRING, CONDUIT, AND TERMINATIONS BETWEEN LIEBERT UNITS, CONDENSERS AND AUTOMATIC CHANGEOVER PANEL AS INDICATED AND SPECIFIED. c. ALL CONTROL INTERLOCK WIRING, CONDUIT AND TERMINATIONS BETWEEN AUTOMATIC CHANGEOVER PANEL AND THE AUTOMATIC TRANSFER SWITCH FOR EMERGENCY POWER OPERATION LOAD SHEDDING AS INDICATED AND SPECIFIED. T CONDUIT ALL _ CONTROL INTERLOCK WIRING, CON_ UIT AND - TERMINATIONS BETWEEN AUTOMATIC CHANGEOVER PANEL AND FIRE SUPPRESSION SYSTEM CONTROL PANEL FOR UNIT SHUT DOWN AS INDICATED AND SPECIFIED. e. COMPLETE WATER TRACE INSTALLATION AND WIRING FROM UNIT TO DETECTOR. f. EQUIPMENT SAFETY GROUNDING TO VERIZON BUSINESS' GROUNDING GRID. 7. ROOF PENETRATIONS AND PIPE FLASHINGS TO BE INSTALLED BY APPROVED ROOFING CONTRACTOR'UNDER MECHANICAL CONTRACTOR BID. 8. WALL PENETRATIONS SHALL BE PROVIDED WITH WALL SLEEVE AND SEALED WATER TIGHT. 9. PROPER LABELING OF ALL NEW HVAC AND ELECTRICAL EQUIPMENT, DISCONNECTS, AND J- BOXES. TO INCLUDE: a. NEW 1 "X4" BLACK LAMINATE LABELS WITH 1/4" WHITE LETTERS ON LIEBERT UNIT AND CONDENSER. b. LAMINATE LABELS SHALL DESCRIBE UNIT, ELECTRICAL PANEL, AND CIRCUIT DESCRIPTION. c. J -BOXES SHALL BE LABELED SHOWING ELECTRICAL PANEL AND CIRCUIT DESCRIPTION. 10. FOR DOWN FLOW RAISED FLOOR APPLICATION, CONTRACTOR TO INSURE BELOW RAISED FLOOR AROUND NEW LIEBERT UNIT TO BE CLEAN BEFORE START -UP. 11. CONTRACTOR SHALL ARRANGE, COORDINATE AND SET UP FACTORY REPRESENTATIVE FOR FACTORY TEST START -U P. i NEER UPON SUBSTANTIAL COMPLETION OF WORK LIST ITEMS WITHIN 5 WORKING DAYS OF PUNCH REVISIGN; No changes shall be made to the scope of work without prior approval of Blinding Division. NOT: I , r��n submittal . and may I,'w: (AD kwira VISION FILE COPY Permit No. .�l� ° � ' Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Co v and conditions is acknowledged: DatB•,, ,, ,. f � 12 City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 3 L 59 [-Expires - I l _Cs MA N < fl� gtz Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 Sheet No, C -1 1Owr In D 0 w „i i w ul o+ 5" in Ili N re W a! 1 > J_ on ZmN COVER SHEET M1 c o ( j VJ LD k LU cws co 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 , n business • EXISTING BUILDING GATEWAY DR. SOUTH SEE PARTIAL FLOOR PLAN FOR NEW WORK IN THIS AREA CODE INFORMATION APPLICABLE CODES: BUILDING INFORMATION: CONSTRUCTION TYPE: V -N (SPRINKLED) OCCUPANCY: B EXIST. BLDG. AREA: 70,775 S.F. TENANT IMPROVEMENT AREA: 9,800 S.F. TELECOMUNICATION EQUIP. AND SUPPORT EQUIPMENT ALLOWABLE FLOOR AREA: FIRE RESISTIVE REQUIREMENTS: EXTERIOR NON - BEARING WALLS INTERIOR BEARING WALLS STRUCTURAL FRAME FLOORS ROOF SHAFTS STAIR ENCLOSURES NON -RATED NON -RATED NON -RATED NON -RATED NON -RATED NON -RATED NON -RATED PROJ. NORTH 2006 INTERNATIONAL BUILDING CODE (IBC) 2006 INTERNATIONAL MECHANICAL CODE (IMC) 2006 INTERNATIONAL PLUMBING CODE (IPC) 2006 NATIONAL ELECTRICAL CODE (NEC) 2006 INTERNATIONAL FIRE CODE (IFC) WASHINGTON STATE BARRIER FREE REGULATIONS LATEST EDITION FEDERAL GUIDLINES AMERICANS WITH DISABILITIES ACT (WAC 51 -20) UNLIMITED PER SECTION 507.4 AUTOMATIC SPRINKLERS THROUGHOUT 60' PUBLIC WAYS ON 4 SIDES SITE PLAN SCALE: 1" = 30' -0" ELO9O(O 1 NQRTN S 130TH s 1 4TH ST ALLENTOWN PROJECT FEB 11 20U9 aty0fTukwila r, . r 1 N RECEIVED CITY OF TUK ILA FEB 0 5 Z009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Drawn By: Designed By: Proj. Mgr.: Date: 02- °02 -09 Revision 02 -02 -09 Project No. WTA. 08093 Sheet No. ARCHITECTURAL SYMBOLS AND NOTES vv-r4 , INI . ONE VILLADE 0519E, 54ITE 500 A EIILEIVE, 'r E:C.A6 71606 1325) 695-1095 E7,}19325) 595.10E1E9 Fac. Code :TYKWWA SHEET SECTION IS LOCATED ON HVAC SYMBOL SECTION NUMBER SYMBOL 1C1:: 0 X01 1I D-- C4 CHECK VALVE SIGHT GLASS PRESSURE GAUGE W /GAUGE COCK. CHS -®-CHS CHR CHR i CRAG # DESCRIPTION EXISTING CONDENSATE DRAIN LINE (SLOPE IN DIRECTION OF ARROW) NEW GRAVITY CONDENSATE DRAIN PIPE (SLOPE IN DIRECTION OF ARROW) PIPE ELBOW TURNED DOWN PIPE ELBOW TURNED UP PIPE TEE TURNED DOWN PIPE TEE TURNED UP PIPE ANCHOR UNION OR FLANGE FLEXIBLE PIPE CONECTION ARROW INDICATES DIRECTION OF FLOW VIBRATION ISOLATOR ISOLATION VALVE EXISTING CHILLED WATER SUPPLY NEW CHILLED WATER RETURN EXISTING CHILLED WATER RETURN NEW CHILLED WATER RETURN TEMPERATURE AND PRESSURE TEST PORT BALANCING VALVE, PLUG TYPE BALANCING VALVE, CIRCUIT SETTER TYPE AUTOMATIC FLOW REGULATOR TRIPLE DUTY VALVE SECTION IDENTIFICATION SYMBOL COMPUTER ROOM AIR CONDITIONER DESIGNATION SYMBOL ICW ICW SS ICW 1 CD . 1 PCD G c � ICI I' VTR BFP FD — FOV — — FOS FOR DESC IPTION OMESiIC COLD WATER PIPE XISTING DOMESTIC COLD WATER PIPE XISTING INDUSTRIAL COLD WATER INDUSTRIAL COLD WATER RAIN AND WASTE PIPE XISTING STORM SEWER LINE XISTING DRAIN AND WASTE PIPE UMICI IER MAKE -UP PIPE ONDENSATE DRAIN PIPE SLOP IN DIRECTION OF ARROW) UMPED CONDENSATE DRAIN PIPE ENT 'IPE XIST NG VENT OR REVENT PIPE XISTING GAS PIPE IPE ELBOW TURNED DOWN r IPE ELBOW TURNED UP IPE TEE TURNED DOWN ?IPE T E TURNED UP U NION OR FLANGE INE SI C E BALL VALVE VALVE APPED CONNECTION CLEA BAC K FLOG FUEL OUT (F.C.O. - FLOOR CLEAN OUT) (W.C.O. - WALL CLEAN OUT) VENT THROUGH ROOF LOW PREVENTER DRAIN IL VENT PIPE FUEL OIL SUPPLY PIPE FUEL OIL RETURN PIPE RROW INDICATES DIRECTION OF FLOW SYMBOL E: T=1 P S DESCRIPTION AUDIONISUAL ALARM APPLIANCE MANUAL FIRE PULL STATION EXISTING SMOKE DETECTOR NEW SMOKE DETECTOR EXISTING UNDERFLOOR SMOKE DETECTOR NEW UNDERFLOOR SMOKE DETECTOR EXISTING HEAT DETECTOR NEW HEAT DETECTOR 44 SYMBOL t o N L 1 I G.F.I. W.P. COR EUES 0 4444:444444 U E P a� r d a 1 } I !i F' 16.:66'i!f! LL�'41l51�tlt.:blt.P.l7 l�(14d UES UEP UES 14444t4444444 4 I4 DESCRIPTION MANUAL MOTOR STARTER SPST WALL SWITCH (SWITCHING FIXTURES WHERE "a" IS INDICATED) 3 -WAY SWITCH NARROW MULLION SWITCH DUPLEX RECEPTACLE - IN WALL L5 -20R RECEPTACLE L6 -30R RECEPTACLE DUPLEX TELEPHONE JACKS (VOICE AND DATA) - WALL MOUNTED ELECTRIC MOTOR (5 HP INDICATED) HP RATED DISCONNECT SWITCH SURFACE MOUNTED PANELBOARD RECESS MOUNTED PANEL JUNCTION BOX WITH COVER GROUND FAULT INTERRUPTOR GROUND FAULT "W.P." BY ANY ELECTRICAL DEVICE SYMBOL INDICATES THAT THE DEVICE IS TO BE WEATHERPROOF CONDUIT "HOME RUN" TO PANEL (HASH MARKS INDICATE THE NUMBER OF CONDUCTORS FLUORESCENT LIGHTING FIXTURE (TYPE "A ") CEILING MOUNTED EMERGENCY FLUORESCENT LIGHTING FIXTURE CEILING MOUNTED DOWNLIGHT FIXTURE /CEILING MOUNTED GROUND LEAD. REFER TO GROUNDING PLAN AND GROUNDING LEAD LIST SCHEDULE WALL MOUNTED LIGHT FIXTURE EXISTING UNDERGROUND ELECTRICAL SECONDARY NEW UNDERGROUND ELECTRICAL PRIMARY (PAVED SURFACE) NEW UNDERGROUND ELECTRICAL SECONDARY (PAVED SURFACE) NEW UNDERGROUND ELECTRICAL PRIMARY (EXPOSED EARTH SURFACE) NEW UNDERGROUND ELECTRICAL SECONDARY (EXPOSED EARTH SURFACE) ELO otoi REVIEWED FOR CONE COMPLIANCE 70 -• NEC FEB 11 20119 City flfTukwlla B ILDIN D I N RECEIVED CITY OF TUKW1LA FEB 0 5 /I III!) PERMIT CENTER WTA - 08093 COPYRIGHT d 2009 WTA, INC. CONSULTING ENGINEER ABILENE, TEXAS . • D __..in a ONE VILLADE DRIVE, SUITE 500 ABI LEN E, TEXAS 750606 (325) 695 -1 090 FAX (325) 695 •3757 [m1 .a4,, �✓ 0i ii' ASJ, , , t'. 0 4 ) qr � ~ !! T l� � 2 ! L L:dpir@S ? 27 V 1 EQUIPMENT ROOMBUILDOT 1 AT Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12-12 -08 Revision 1 01 -05 -09 95% REVIEW 2 01 -15 -09 100% CD 3 01 -26 -09 ADD. NO. 1 4 02 -02-09 PERMIT SET Project No. WTA. 08093 Sheet No. MPE-1 MPE SYMBOL LEGENDS SHEET SECTION IS LOCATED ON HVAC SYMBOL SECTION NUMBER SYMBOL 1C1:: 0 X01 1I D-- C4 CHECK VALVE SIGHT GLASS PRESSURE GAUGE W /GAUGE COCK. CHS -®-CHS CHR CHR i CRAG # DESCRIPTION EXISTING CONDENSATE DRAIN LINE (SLOPE IN DIRECTION OF ARROW) NEW GRAVITY CONDENSATE DRAIN PIPE (SLOPE IN DIRECTION OF ARROW) PIPE ELBOW TURNED DOWN PIPE ELBOW TURNED UP PIPE TEE TURNED DOWN PIPE TEE TURNED UP PIPE ANCHOR UNION OR FLANGE FLEXIBLE PIPE CONECTION ARROW INDICATES DIRECTION OF FLOW VIBRATION ISOLATOR ISOLATION VALVE EXISTING CHILLED WATER SUPPLY NEW CHILLED WATER RETURN EXISTING CHILLED WATER RETURN NEW CHILLED WATER RETURN TEMPERATURE AND PRESSURE TEST PORT BALANCING VALVE, PLUG TYPE BALANCING VALVE, CIRCUIT SETTER TYPE AUTOMATIC FLOW REGULATOR TRIPLE DUTY VALVE SECTION IDENTIFICATION SYMBOL COMPUTER ROOM AIR CONDITIONER DESIGNATION SYMBOL ICW ICW SS ICW 1 CD . 1 PCD G c � ICI I' VTR BFP FD — FOV — — FOS FOR DESC IPTION OMESiIC COLD WATER PIPE XISTING DOMESTIC COLD WATER PIPE XISTING INDUSTRIAL COLD WATER INDUSTRIAL COLD WATER RAIN AND WASTE PIPE XISTING STORM SEWER LINE XISTING DRAIN AND WASTE PIPE UMICI IER MAKE -UP PIPE ONDENSATE DRAIN PIPE SLOP IN DIRECTION OF ARROW) UMPED CONDENSATE DRAIN PIPE ENT 'IPE XIST NG VENT OR REVENT PIPE XISTING GAS PIPE IPE ELBOW TURNED DOWN r IPE ELBOW TURNED UP IPE TEE TURNED DOWN ?IPE T E TURNED UP U NION OR FLANGE INE SI C E BALL VALVE VALVE APPED CONNECTION CLEA BAC K FLOG FUEL OUT (F.C.O. - FLOOR CLEAN OUT) (W.C.O. - WALL CLEAN OUT) VENT THROUGH ROOF LOW PREVENTER DRAIN IL VENT PIPE FUEL OIL SUPPLY PIPE FUEL OIL RETURN PIPE RROW INDICATES DIRECTION OF FLOW SYMBOL E: T=1 P S DESCRIPTION AUDIONISUAL ALARM APPLIANCE MANUAL FIRE PULL STATION EXISTING SMOKE DETECTOR NEW SMOKE DETECTOR EXISTING UNDERFLOOR SMOKE DETECTOR NEW UNDERFLOOR SMOKE DETECTOR EXISTING HEAT DETECTOR NEW HEAT DETECTOR 44 SYMBOL t o N L 1 I G.F.I. W.P. COR EUES 0 4444:444444 U E P a� r d a 1 } I !i F' 16.:66'i!f! LL�'41l51�tlt.:blt.P.l7 l�(14d UES UEP UES 14444t4444444 4 I4 DESCRIPTION MANUAL MOTOR STARTER SPST WALL SWITCH (SWITCHING FIXTURES WHERE "a" IS INDICATED) 3 -WAY SWITCH NARROW MULLION SWITCH DUPLEX RECEPTACLE - IN WALL L5 -20R RECEPTACLE L6 -30R RECEPTACLE DUPLEX TELEPHONE JACKS (VOICE AND DATA) - WALL MOUNTED ELECTRIC MOTOR (5 HP INDICATED) HP RATED DISCONNECT SWITCH SURFACE MOUNTED PANELBOARD RECESS MOUNTED PANEL JUNCTION BOX WITH COVER GROUND FAULT INTERRUPTOR GROUND FAULT "W.P." BY ANY ELECTRICAL DEVICE SYMBOL INDICATES THAT THE DEVICE IS TO BE WEATHERPROOF CONDUIT "HOME RUN" TO PANEL (HASH MARKS INDICATE THE NUMBER OF CONDUCTORS FLUORESCENT LIGHTING FIXTURE (TYPE "A ") CEILING MOUNTED EMERGENCY FLUORESCENT LIGHTING FIXTURE CEILING MOUNTED DOWNLIGHT FIXTURE /CEILING MOUNTED GROUND LEAD. REFER TO GROUNDING PLAN AND GROUNDING LEAD LIST SCHEDULE WALL MOUNTED LIGHT FIXTURE EXISTING UNDERGROUND ELECTRICAL SECONDARY NEW UNDERGROUND ELECTRICAL PRIMARY (PAVED SURFACE) NEW UNDERGROUND ELECTRICAL SECONDARY (PAVED SURFACE) NEW UNDERGROUND ELECTRICAL PRIMARY (EXPOSED EARTH SURFACE) NEW UNDERGROUND ELECTRICAL SECONDARY (EXPOSED EARTH SURFACE) ELO otoi REVIEWED FOR CONE COMPLIANCE 70 -• NEC FEB 11 20119 City flfTukwlla B ILDIN D I N RECEIVED CITY OF TUKW1LA FEB 0 5 /I III!) PERMIT CENTER WTA - 08093 COPYRIGHT d 2009 WTA, INC. CONSULTING ENGINEER ABILENE, TEXAS EL PARTIAL MEZZANINE FLOOR PLAN SCALE: 3/32" = 1' -0" alp RAGE kil=t E_AK REFER TO SHEET E -5, E -10, DC -5, AND DC -8 FOR WORK IN THIS AREA. FIRE PANEL EMS PANEL REFER TO SHEET M -5 AF' E -7 FOR WORK IN TF IS AREA. I-.(:) 0 . DING PUMP EXISTING AIR COOLED CHILLER #1 A IV I1°1. NOM E N L� Q. . I] MEN E:.. loon 1Inrrrn 5TIUM 41 1Y111'ff E 114f.- 11Ii�11E11V CIC 4:IPIlIR tI ^- R4W,1 3431.,11,1114117 T 1 CHS CH .fir- •� r-.._. 0 0 0 0 0 0 3 0 •r. . 5.1 1-4. Iri W 14..q 11543 1150/ IA>A: 141.1 141 A 11't1K 14100 1 143344 144 01 144 00 MOO 141 10 I FA 111111111111111 I M. 4 42. 14130 1 11 143.11 14.1 14 141 10 l4 NEW POU 150 NVA 41,11 I17.15 _..1T..._ :_ IT UMW 44M ,111 ., . ,3..11" 104,1 - _iAS 4 i .11 131 12 144, 134.14 101.14 id/ IS 10/ MA MA W. m. mu 143 14 14,14 141.15 141 •1. 411/ lIlIlIlIlIlull mm Mal wo mm WM m. / 4,30 16/31 13.1 l 11131 i eum int 1, IIIIIIILIlIlIl .101111. ! ' :4 x74:4. == 1,77===.7.11=.. EXISTING EXISTING AIR COOLED CHILLER #2 ANDI NEW AIR COOLED CHILLER #3 -08 1 131•3441.1.4.0 .1344 JI 1.;4,1.11111( i1 1 1 UEIELiNY SSE RI \I :r ROOM FUTURE UPS. SIXIMA r. FUIUNE UPS 600 NVA pO W1VEI ROOM NOTES INDICATED BY NUMBER IN 0 1. SMOKE DETECTOR LOCATOR DRAWING. CONTRACTOR SHALL MODIFY AND UPGRADE DRAWING TO SHOYV NEW EQUIPMENT ROOM WITH ANY APPLICABLE CHANGES. GENE RATOR EN CI_,11f'° NEW UPS 29 580NVA FF RAMP FUfUAEUPSOA 580 NVA Um 4880J1N011 f'Y. L t VEL IECY. u V y 4uE 1., 1 err, mcr mm qur RE. 0 4 • 1 N448,8, 11 rte, 44114. > " RAN Sl = 1, 1 1 6 t ,_._._" _,. 1 M 01 4. E 8.1414 31 41 Fu4u4« '8 ie�w s � RrR:IDOI OVERALL FLOOR PLAN - MECHANICAL AND ELECTRICAL R., 141 :a4111.1O.al Ol le>.- 1,10114 41111U11TJtl • ;• . �1%1 0414.18'4 L 4:141•4111 IAMB 11051 444, FE 01 2,11488. 1,011 81541 ( U1,1 ACCESSIBLE 4814 ELO°t 11 REFER TO SHEET E -6 FOR WORK IN THIS AREA. l u - REVIEWED FOR E COMPLIA NCE FPA 70 - NEC FEES 11 An �tYfl��uktiita I WVVG DINT ION REFER TO SHEET M -4, P -4, FP -2. FP -4, E -4, E -9, DC -2, DC -4, AND DC -7 FOR WORK IN THIS AREA. 'uv E ';,Il,.i'i l�d5lfl:ml11 REFER TO SHEET M -3, P -3, FP -1, FP -3, E -3, E -8, DC -1, DC -2, AND DC -6 FOR WORK IN THIS AREA. RECEIVED CITY OF TUKWILA FEB 0 5 2Q(lq PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 01 -05 -09 2 01 -15 -09 3 01 -26 -09 4 02 -02 -09 Sheet NO. Fac. Code,:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Prof, Mgr.: KCM Date: 12.12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 OVERALL FLOOR PLAN - MECHANICAL AND ELECTRICAL 3 02 -02 -09 PERMIT SET Project No. WTA. 08093 MATCHLINE 1-..K1 ST1 NC3 UIPIVONT R OO EXIS J -BO REL . SECUR. TO BE TED. 2 144.03 144.04 144.05 144.06 144.07 144.08 144.09 144.10 144.1 143.05 143.06 143.07 143.08 143.09 143.10 143.1 142.05 142.06 142.07 142.08 142.09 142.10 142.' - DP2 = =1 ir - IFIe m w m • 1 wirret w ®-m-su w el do • is a 1www r ii C ;146 i 142.02 NEW PDU 150 KVA NEW PDU 150 KVA ON RDPAI -350 RAMP 2. L5 -20R RECEPTACLE SHALL BE IDENTIFIED AS 3. L6 -30R RECEPTACLE SHALL BE IDENTIFIED AS REFER TO E -4 FOR CONTINUATION 142.03 142.04 145,05 145.06 145.07 w W WW WWWi" W MW MMIMwrui iaW W GENERAL NOTES:, 1. ALL NEW AND EXISTING CONDUITS PENETRATE NEW WALL SHALL BE INSTALLED OR RETROFITED WITH PLASTIC COUPLER AS SHOWN ON DETAILS 3 AND 5 ON SHEET E -17. . io-wW 1.i,: r);' EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. IH WI MI SIm WIMmm,ii edm m ee - ; Ei '1' 44.12 143.12 142.12 144.13 144.14 143.13 WWWW 143.14 RDPA1 142.13 142.14 142.15 IMMIMMO WWfr W WOMAN .1.0 15 URDP1 -3 -2 144.15 144.16 144.17 144.18 143.15 143,16 NEW PDU 150 KVA DP2B.4 143.17 143.18 142.16 142.17 142.18 RPPA1- 0,22,24 1 1 / 1 / 1 1 I l 1 1 ■ N DPA1 =+ 8 -_.._. mmer WHIAMMIM 1I5;" .01 109 02 167.01 1 FUTUR PDU (2) L5 167.02 NEW PDU 150 KVA 165.02 167.03 NEW PDU 150 KVA h.., .165.03 ew ir- era�•A :3 109 04 Ir -)Cr k Amer W WWWW 166.03 67.04 _'165.04 166.04 165.05- 164.04 '164.0 05 167.06 167.07 167.08 167.09 ON .URDp13-4 2 166.05 165.06 -- 164.06 166.06 166.07 166.08 165.07 - -- .- 165.0E3..- .- 165,09 -. 164.07 164.08 . .. L 5 -20R- AND ( 167.10 166.09 165.1(1. 167.11 166.10 164.11 ) L6 =3 167.12 166.'11 165.11 - . 165.12- 164.'12 167.13 166.12 .165.13 164.13 166.13 165.:14_ 164.14 PB1 -3 .14 '167.15 167.16 167.17 ON RDP EXISTING SECURITY BOX TO BE RELOCATE Expires 4?-.4t., 1 Drawn By: Fac. Code :TYKWWA Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12- '12 -08 Revision 01 -05 -09 95% REVIEW 01- 15-09 100% CD 01 -26 -09 ADD. NO. 1 Sheet No. PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - SOUTH ON URDP1 -3 -2 1111-111- SCALE: 1/4" =1 EX. __CI PPA1 14,16,1 NOTES INDICATED BY NUMBER IN 0: 1. PDU INPUT J -BOX FURNISHED WITH PDI, INSTALLED BY CONTRACTOR. REFER TO DETAIL. INSTALL J -BOX ON TRANSIENT SUPPRESSION PLATE. CONNECT THE INDICATED UPS OUTPUT FEEDER TO J -BOX. 2. PDU TRANSIENT SUPPRESSION PLATE (TSP) FURNISHED WITH PDU, INSTALLED BY CONTRACTOR. REFER TO DETAIL 2, SHEET E -17. GROUND TSP AS INDICATED ON GROUNDING FLOOR PLAN. OWNER FURNISHED, CONTRACTOR INSTALLED PDU. PDU IS PDI MODEL NO. PP -134- 150- G641- 0- 4D -MDP, 150KVA PDU. INSTALL ON PDU FLOOR STAND AS INDICATED ON DETAIL 1, SHEET E -17. EACH PDU IS EQUIPPED WITH (4) DISTRIBUTION PANELS LOCATED ON PDU SIDE CAR. 4. EXTEND THE INPUT J -BOX FACTORY WHIP AND TERMINATE AT PDU MAIN INPUT CIRCUIT BREAKER. 5. RELOCATE EXISTING DUPLEX RECEPTACLE TO FACE OF NEW WALL. 6. FACTORY DISCONNECT AT FRONT OF CRAC UNIT. 7. LIEBERT SITE LINK COMMUNICATION CABLE IN 1" CONDUIT FOR EACH CRAC UNIT. 8. FOUR SITE LINK COMMUNICATION CABLES IN 1 -1/2" CONDUIT TO EXISTING SITE LINK PANEL IN POWER ROOM. r L r . 1777 _ _ EX CRP - 13 15;17` ER N5 Iiiii ma 4iti Es mi sot au mri. pi Nardi FUTUR PDU - C0Rl I[ OR mmm•I M 1119 Ck■ PARTIAL FIRST, FLOOR PLAN - ELECTRICAL POWER wWWww 109 011 10. (2) L5 -20R RECEPTACLES PER RACK FOR ROWS 165, AND 166. 11. (2) L5 -20R RECEPTACLES PER RACK FOR ROW 164. 12. (1) L5 -20R RECEPTACLE, (2) L6 -30R, AND (2) L6 -30R REDUDANT RECEPTACLES PER RACK FOR ROWS 142 AND 143. 13. (1) L5 -20R RECEPTACLE, (2) L6 -30R, AND (2) L6 -30R REDUDANT RECEPTACLES PER RACK FOR ROWS 144 AND 145. WWWW '1 111 07 SOUTH 9. PDU NETWORKING CABLEIIN 3/4" CONDUIT BELOW RAISED FLOOR. REFER TO PDU INTEGRATION DIAGRAM. 14. EXTEND EXISTING FEEDER CIRCUIT TO NEW LOCATION OF CRAG UNIT TO ALLOW FOR NEW SECURED WALL CONSTRUCTION. 15. FEEDER CIRCUIT FOR NEW CRAC UNIT FROM PANEL INDICATED. PULL CIRCUIT IN EXISTING UNDERGROUND CONDUIT ALREADY IN PLACE. VERIFY LOCATION OF RISER THRU FLOOR AT JOB SITE. CIRCUIT SHALL BE 3- #10'S, 1 410 GND., IN EXISTING 1 " CONDUIT. 16. INSTALL RECEPTACLE IN SURFACE MOUNTED OUTLET BOX BELOW RACK. DO NOT ANCHOR BOX TO FLOOR. BRANCH CIRCUIT SHALL BE INSTALLED IN SEAL -TITE FLEXIBLE CONDUIT EXTENDED FROM INDICATED PDU. LABEL CONDUIT AND OUTLET BOX WITH CIRCUIT NUMBER AS INDICATED ON PDU PANEL SCHEDULES. WWWWWWWWWW mm®mm 109,03 169 .C19 16%6 e_i ia ll ire WW m- . mm A lm -- HFerW W W (2 l 'u- e. - ammmw t/,1, 10 169 '11 L REFER TO E -4 FOR CONTINUATION i iJ 1 it I / { t'i <i r erm w m w w erel-w ererWWW erererrr trr� r E'33:1 12 169 1'3 as �ui m -el ON UROP1 -3 -6 �iwa�rare ON RDP WerWWY#WWW gOmma 109.1.1 333 '15 I 100.' ( , I•t) '17 /'i i. 1lk5 - 11.1U. m m-samm m- muiie>H ®Hii- fiew®Ym- M -etww W mwm iJ -mmiw oesl1-el 'mfie-erw (2)- L5-20R 1 22. J -BOX FOR FUTURE PDU CONNECTION. ISTIN G CURITY BOX LOCATED 17. PDU FEEDER CIRCUIT FROM EXISTING UPS OUTPUT PANEL "UPP1" WHICH IS FED FROM EXISTING UPS -1A. REMOVE EXISTING 80A, 3 -P CIRCUIT BREAKERS NOT USED AND INSTALL A NEW 250A, 3 -P CIRCUIT BREAKER TO SERVE THIS PDU. REFER TO "ONE -LINE DIAGRAM ". 18. LOCATION OF FUTURE PDU INPUT J -BOX AND TRANSIENT SUPPRESSION PLATE. DO NOT INSTALL CONDUITS OR PIPES AT THIS LOCATION. 19. EXISTING PDU1 -2, ASSOCIATED FEEDER CIRCUIT AND ALL BRANCH CIRCUITS SHALL REMAIN. 20. EXISTING OUTLET ON CORD REEL TO REMAIN. LOCATE CIRCUIT CONDUIT AT JOBSITE. WHERE CIRCUIT CONDUIT PENETRATE NEW WALL, CUT CONDUIT AND INSTALL NONMETALLIC CONDUIT ADAPTERS. REFER TO DETAIL 5, SHEET E -17. 21. EXISTING WALL MOUNT TELEPHONE, TELEPHONE JACKS, AND TELEPHONE CABLE SHALL BE REMOVED. PROVIDE BLANK COVERPLATE AT EXISTING OUTLET BOX. 23. PROVIDE NON - METALLIC CONDUIT COUPLER AT SECURED WALL PENETATION. REFER TO DETAIL 5, SHEET E -17. EL.0%.- 0 10 ( STING LIGh rQHBANK MATCHLINE 1 CODE REVIEWED FOk COMPLIANC NFPA 70 NEC 1-63 11 21109 city�rukwtla 6UILDOI Dom RECEIVED CITY OF TUKWILA FEB 05 ?MN PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS REFER TO __ ___._ E -5 FOR CONT. FUTURE PANEL "DP4 • � to Y di iS 'xu WY: WA Gil W ffili W W 9191 W W w iM M iii' W aN 6C lla Sii &i "W M Na 1 R'i U N 1911 ALi W Ike W M U W tl ti!' u W ilA ii1 IA = W 3W ;& 'i Lot w2 W .371 J';5 l'tJ vti .ml Ui! :. 117e +! :'eJ 8A ,G >aU M : M i1f .Ld il'W V61 LYl l W W H SJ [ W iU Jb coma-m.1. �.. ..�_•..� ..� . , . ..._ . ..__ _. .. .� �. _�_ ®. T . . MATCHLINE EX I a T i N t E( l_JIt VlE _6'NNT ROOM OM EXISTING CSI/TAC BUILDING AUTOMATION SYSTEM (CONTROL PANELS _ -23 �► 1101, 150 () I 150.05: ON DP 1 -35 tetetwkwilvW-t -- all uam�t FUTUR PDU ew es W W 1(11:606 REFER TO E -3 FOR CONTINUATION GENERAL NOTES: 1. ALL NEW AND EXISTING CONDUITS PENETRATE NEW WALL SHALL BE INSTALLED OR RETROFITED WITH PLASTIC COUPLER AS SHOWN ON DETAILS 3 AND 5 ON SHEET E -17. FUTUR PANEL 'DP3A" te1 Hr ;I� I 1;: . I (*WIN- - W7 mm ei- m -IaFI111 d a■7e - 7aF ad hW i..)tal I;.i)i.) +i 15C09 !1 11 WOW WOW 1 :.3n 11 EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS R TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SIT VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID I ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWN _-R, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABS ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SIT PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS �I CESSARY TO DETERMINE THE COMPLETE EXTENT OF THE R QUIRED. THE CONTRACTOR SHALL ADVISE THE CHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO BMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNE OR ARCHITECT /ENGINEER. RDP1- WWWWW mm*M! 111140 SCALE: 1/4" =1 attwi ieo-et - fit w W W ®W W WWW 15u . 1:Y4. 1 •:t; I 154. 17 154 0 ON URDP1 -1 2 mm- rwod -- - - -W ttm-- pa- etor -t ae - --m WW--- W iF eEW rg 1191 W w11a m %11 U 1 1 '•:111: i;".1 I 1tJ! I i l ON "CRPPA1 "_ RDPA' mwm -"m Www." 91we1-0461- www 150 15 150 10 '150 '1'7 ! !!1 J;A ti 7 1 ! i i I!IR9 ■`:! te1 -Bat WWWW W- -- -W• eFWtat- m-a4Ft43 aoFtartwt 150 '18: ON RDPA -28 PANEL "BPPA2" ON RDP 1 -24 PANEL "BPPB2" = NOTES INDICATED BY NUMBER IN 0: 1. EXISTING CRAC POWER PANEL WITH FEEDER CIRCUITS INSTALLED UNDERGROUND TO EXISTING CRAC UNITS. PER RECORD DRAWINGS, UNDERGROUND EMPTY CONDUITS WERE ALSO INSTALLED FOR FUTURE CRAC UNITS. 4. CONNECT NEW RECEPTACLES TO A 20A, 1 -P SPARE CIRCUIT BREAKER IN EXISTING UPS POWERED PANEL. 5. PROVIDE NON - METALLIC CONDUIT COUPLER AT SECURED WALL PENETATION. REFER TO DETAIL 5, SHEET E -17. 6. EXISTING OUTLET ON CORD REEL TO REMAIN. LOCATE CIRCUIT CONDUIT AT JOBSITE. WHERE CIRCUIT CONDUIT PENETRATE NEW WALL, CUT CONDUIT AND INSTALL NONMETALLIC CONDUIT ADAPTERS. REFER TO DETAIL 5, SHEET E -17. 17 =51.1 2. RELOCATE EXISTING DUPLEX RECEPTACLE TO FACE OF NEW WALL. 3. LOCATION OF FUTURE PDU INPUT J -BOX AND TRANSIENT SUPPRESSION PLATE. DO NOT INSTALL CONDUITS OR PIPES AT THIS LOCATION. ar- ar -- 1'71 :. }1 FUTURE PDU om04614.1- 0411- 110 '175.02 175 c;3 FUTUR PDU FUTUR PDU 171.02 E CRPP1B1 - 8,10,12 NEW 111 -41&4111-111a-V11-111 173 C711 173. f",65 e ttmr -W -W w - - -1111 1 t;3 171 04 1'71 Uri Nlrl ll...i tut 1 1..' I i4?I 1 CJ w a i l s m- muea p�ao-ea ra 1'75,04 l'7Fi 05 175 C.6611 PARTIAL FIRST FLOOR PLAN ELECTRICAL_ POWER -NORTH 170.08 maa- mrnm wilco- re ommim- tart '171.075 PANEL_ _... .. ,,' "ULPP1 -1" � W.,,,...., ANALASER ZONE 4 BOX M1 ,) Iul .. ON URD 1 -3 -4 (N URDP -3 -4 010-60-0- -mmmm- 170 07 175.0 1141,i,!''A 1 / 01!!! 174 07 174 t m -m -m- taa4fw aFmm 17'1.0T MLWO 9 dG f,<Y&#1"+YMLLW OM4117Yir4 Ci..ii'4. WPJ4EA MW Kit"41WUWAH8WA W" Mal - ...."I MN= NMI , _ A qgra..,..I 37:. Cal 172.6.1 1 172.00 I '112(.)1 - 17J:'. .0 1 ewteam - - -- -w ttfar --w-- - -m --w 61-0S-1111-1111 016-111H11111 17CiIre 'i_'d 1 r' , � -f:ii -w® -- w - - m l7:::09 lil.l „ 4 _10 v(2. 11 1(2.12 1T2.1:5 XFMR UTRL1 -1 I; "6:1.1t3 yi. "I 1 17;;k 111 • 1 ".:i, t. B ee W - WW W W 't ':;:; 1:V!!1') i'F CD 1.7111.! 1:2..0 li.' 1 "1 12. J -BOX FOR FUTURE PDU CONNECTION. BATTERY 1D BATTERY C BATTERY 15 tW m -® -W 11 177 12 muckwei- 17'5 1 7. EXISTING WALL MOUNT TELEPHONE, TELEPHONE JACKS, AND TELEPHONE CABLE SHALL BE REMOVED. PROVIDE BLANK COVERPLATE AT EXISTING OUTLET BOX. 11. DROP DOWN AND TERMINATE INTO 6 " JUNCTION BOX ABOVE CSI/TAC PANEL. EXTENSION OF CONTROL WIRING TO PANEL SHALL BE PROVIDED BY OTHERS. 8. PDU NETWORKING CABLE IN 3/4" CONDUIT BELOW RAISED FLOOR. REFER TO PDU INTEGRATION DIAGRAM. WW WW . r' • / 1 i 10. (2) PDU NETWORKING CABLES IN 1" CONDUIT OVERHEAD TO CSI/TAC PANEL, INSTALL AS HIGH AS POSSIBLE. REFER TO PDU INTEGRATION DIAGRAM. 9. PDU NETWORKING CABLE IN 3/4" CONDUIT OVERHEAD, ROUTE AS HIGH AS POSSIBLE. REFER TO PDU INTEGRATION DIAGRAM. �.�. gem -. -.m 177.14 1 .1(1 sawaa -®}a ray taeae -4 rommmauel . 17 3 1 1 1 :r 1 7 3.14 I l ,'1 i !] FROM EXISTING PANEL "UPP1 ". REFER TO E -6. Ail Iul V!7 9W W YW Uoi . ?i5 IL] 6.11 AJ iv '"A W 41 "il utt oi4l S%i k16 • lt. W YW U W 4'il JW d;U iJ.i 4 i Id.I 1A1 L'q IU =U PR1 TO PDU 7 6.01 W m-atm - ateaa- oma-a.m aaime� REFER TO E -3 FOR CONTINUATION WWWW BATTERY 1A e11WWMN star- 1191-W w - _ mm- -m- 1111wt11a eFttm mmmm -* t ---- 1'71.11 1'7°1 12 1'71.11 - 1'71.'1! 1 15; 1 ,71 'id 171 '67 1'7 1 lb' UPS -1 EL. 01 Lic r; ;2 5t;9 Expires' > /��1 Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 Sheet No. PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - NORTH REFER TO E -6 FOR CONTINUATION RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS ANALOG DATA POINTS INDEX STATUS ALARM SCALE NOTE MEM MEM 0 INPUT VOLTAGE A -B - ' , NONE 1 INPUT VOLTAGE B-C 16 BIT INTEGER NONE 2 INPUT VOLTAGE C -A 16 BIT INTEGER NONE 3 OUTPUT VOLTAGEA -B 16 BIT INTEGER NONE 4 OUTPUT VOLTAGE B-C 16 BIT INTEGER NONE 5 OUTPUT VOLTAGE C -A I=1 NONE 6 OUTPUT VOLTAGE A -N 16 BIT INTEGER NONE MUNI 7 OUTPUT VOLTAGE B-N 16 BIT INTEGER NONE 8 OUTPUT VOLTAGE C -N 16 BIT INTEGER NONE ig is 10 OUTPUT AMPS A 16 BIT INTEGER NONE OUTPUT AMPS B 16 BIT INTEGER NONE M OUTPUT Eig En 16 AMPS C NEUTRAL AMPS 16 BIT INTEGER NONE ■ 16 BIT INTEGER NONE GROUND AMPS 16 BIT INTEGER NONE KW A 16 BIT INTEGER NONE 17 16 BIT INTEGER *100 100 =UNITY PF MIIIMMI IIIIMIII MIME ICII 19 KW B 16 BIT INTEGER NONE = :: - NONE 20 KW C NONE - 16 BIT INTEGER NONE 22 KVA A CUM= NONE E N 24 THD A 16 BIT INTEGER NONE `, ■ KVA B 16 BIT INTEGER NONE M E THD B 16 BIT INTEGER NONE 5 =5% DIGITAL DATA POINTS NAME STATUS ALARM ALARM LATCHED ALARM ACKNOWLEDGE TRANSFORMER HI TEMP 39 215 567 39 PHASE ROTATION ERROR 40 216 568 40 SYSTEM SHUTDOWN 42 218 570 42 TOTAL KVA HIGH 252 604 76 GFI WP E EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER -24 BATTERY MATCHLINE r FUTURE UPS BATTERY 5A CELLS 1 -240 EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. 1 r l : ❑ EXISTING CSI IN EX ST. EN-23-� I_ PAIR. LEO NO SCALE FUTURE BATTERY 5B DISCONNECT --- 480V., DC, 1200A 401 A1111 N2 TRUNK IN FROM CSI ❑ CSI/rAC BATTEITY BATTERY a JU UBLE UABLE D LED (SET TO ENABLE) PORT P� P1R &211 Pail &222 PJFM-131 PDI POWERPAK C6. SPDB #1 4 "x4" COLUMN (TYP. THIS ROOM) SPDB #1 TX-n RCn B &8 ELECTRONICS RS -232 TO R8-085 CONVERTER CVT -1 MPDB RE( 1 EX. CSI/TAC PAN AVAILABItJTY OF ( SIGNAL CONVER EXIST NG 120VAC �S -485 p162 D MAINT ONFI PDU INTEGRATION DIAGRAM RECT. 3 r RECT. 5 . VERIFY ONTROLLER AND :R AT JOBSITE. TABLE - BELDEN NO. JOT T -TAP ALWAYS DAISY CHAIN RATION IN 3/4" C. DR =1 ADDR =2 GRAWP TURE REMOVAL OF (STING 48V. BATTERY 9R INSTALL OF BATTERY A CELLS 121 -240. C1: RECT. RECT. 7 9 FZE RECT RECT. RECT. RECT 4 6 8 10 FUTURE FUTURE PANEL "DP5A'L, PANEL "DP4E�' AT1111 SCALE: 1/4" = 1' -0" I 2 L B &B ELECTRONICS RS -232 TO RS.485 CONVERTER CVT•2 NEW PDU 145.16 DR =1 ADDR =2 ADDR =3 ABLE - BELDEN NO. NOT T -TAP ALWAYS I DAISY CHAIN ) (RATION IN 3/4" C. FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A EXI STI N BUILpIN 1 SYSTEM DCGB -2 CRAG #27 DSB1 31,:13,35 PIN NO.1 2 3 4 5 6 6 7 a 9 B &B ELECTRONICS RB232/RE485 CONVERTER 485TBLED WITH EXTERNAL POWER SUPPLY 485P62 (NO ECHO & RIB CTRL) RS-485 CONVERTER ROOM FUTURE UPS 5A 500 KVA NEW UPS 213 500 KVA 0.9 PF FUTURE UPS 3A 500 KVA CSI /TAC AUTOMATION CONTROL PANELS BRGB -1 ❑ ❑ ❑ isra I dEY u'8 !litl tJ YkE fall LEI EA Lu ifa Ea C91 ra Ea EA 5J Ad Ed El a) 19 311 d.6 6EU d.S Eu Cc! &i "Y' [1d 514 NE EN LEI IA Ell LW i{19 CA 3R NE IC! ME aCl Nil LEI Olt ME Eta ME NA NG EA NCI Al Ya[ Ri ULE LIE 01 011A Ur9 GB ita tlGi EA INI INi AEI EA GUI al 'MIT LN uld tEd NCE 04 kbl IEB Y'7 YAP AGB� REFER TO SHEET E -4 FOR CONTINUATION PARTIAL FIRST FLOOR PLAN -POWER ROOM ELECTRICAL MAINTAIN POLARITY TX PAIR SHOULD BE TWISTED TOGETHER, RCV PAIR LIKEWISE. USE SHIELD FOR GROUND. D825 MALE R6445 TRUNK TD(A) TD(B) RD(A) RD(B) GND +12VD c J6 RX- RX+ TX- TX+ GND PDU POWER ROOM J7 RX- RX+ TX- TX+ GND CRAC #28 DSA1 25,27,29 J6 RX- RX+ TX- TXF GND PDU J7 RX- RX+ TX- TX+ GND eurigcitr iffau fiffif+ NEW CONC. PAD. I REFER TO DETAIL. BATTERY ALARM/ 1 CONTROL CIRCUIT -I 7" 7" PDU REMOTE COMMUNICATIONS TRUNK CONNECTIONS, J6 AND J7 AT CONTRACTOR BOARD INSIDE PDU. TO NEXT PDU'S SEE DETAIL, THIS SHEET GROUND TERMINATED ONLY AT MIG AND LAST PDU 2 PDU SEPoALINTERFACE �os�A�E v ---- CS /TAC UPS INTEGRATION IN 3/4" CONDUIT - REFER TO DETAILS ON E -12. 1 -3/0 GND. IN 2 "C. (PVC) TO BATTERY ROOM GND. BAR (BRGB -1). D'CGB - -FGB -1 RECT. 9 7 BATTERY 2B DISCONNECT 480V. DC, 1200A. REFER TO DC DRAWINGS. RECT. 1 RECT. 5 RECT. RECT. RECT. RECT. RECT. 10 8 6 4 2 ANALA ER ZONE 3 BOX mV (n (NI N D- y- w z mw U 0 2 w W Ce U I 1 FUTURE 1 NEW PANELBOARD 1 PANEL "DP3A'k "DP2E " I NO SCALE ❑ E FUTURE BATTERY 3B DISCONNECT 480V. DC, 1,200A r PANE "CRPPJ _ PDU DATA POINTS 6 EXISTING TERM. PLANT #2 STRIN #3 1 ROW, 2 TIER -24 BATTERY EXISTING TERM. PLANT #2 STRING #4 1 ROW, 2 TIER -24 BATTERY r CityafTukwila IIDING DIVISION EXTEND NEW TELEPHONE CABLE IN 3/4" CONDUIT TO TELEPHONE SYSTEM LOCATED ON MEZZANINE FLOOR. ROUTE CONDUIT OUTSIDE NEW EQUIPMENT ROOM. REVIEWED FOR CODECOMPLIANCE NFPA10- FEB 11 2UO9 FUTURE UPS BATTERY 3A CELLS 1 -240 EXISTING WALL MOUNTED TELEPHONE. E1.0 010 1 r 2 W z ,, - "I I< MATCHLINE EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL. INDEX 26 27 28 29 32 33 34 35 36 KVA C NAME ANALOG DATA POINTS TYPE 16 BIT INTEGER THD C 16 BIT INTEGER TOTAL KVA 16 BIT INTEGER FREQUENCY 16 BIT INTEGER PERCENT KVA A 16 BIT INTEGER PERCENT KVA B 16 BIT INTEGER PERCENT KVA C 16 BIT INTEGER KWH 16 BIT INTEGER PF C 1 16 BIT INTEGER SCALE NONE NONE NONE *10 NONE NONE NONE HIGH WORD LOW WORD 5 =5% NOTE 600 -60 HZ 75 =75% 75 =75% 75 =75% KWH IS A 32 BIT UNSIGNED INTEGER DIVIDED INTO (2) 16 BIT INTEGERS RECEIVED CITY OF TLJ WILA FEB 0 5 log ly PERMIT CENTER WTA - 08093 COPYRIGHT 02009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 1 D t' o '''M W I- U' g• j") N - % O W k W ' o big >AJ W"' n ZWN O Q3 z kft LD (f) 1 w U) cf) cb cif) Fac. COde:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Praj. Mgr.: KCM Date: 12-12-08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02-02 -09 100% CD Project No. WTA. 08093 Sheet No. E -5 95% REVIEW ADD. NO. 1 PERMIT SET PARTIAL FIRST FLOOR PLAN - POWER ROOM, ELECTRICAL � 1 � GFI WP E EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER -24 BATTERY MATCHLINE r FUTURE UPS BATTERY 5A CELLS 1 -240 EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. 1 r l : ❑ EXISTING CSI IN EX ST. EN-23-� I_ PAIR. LEO NO SCALE FUTURE BATTERY 5B DISCONNECT --- 480V., DC, 1200A 401 A1111 N2 TRUNK IN FROM CSI ❑ CSI/rAC BATTEITY BATTERY a JU UBLE UABLE D LED (SET TO ENABLE) PORT P� P1R &211 Pail &222 PJFM-131 PDI POWERPAK C6. SPDB #1 4 "x4" COLUMN (TYP. THIS ROOM) SPDB #1 TX-n RCn B &8 ELECTRONICS RS -232 TO R8-085 CONVERTER CVT -1 MPDB RE( 1 EX. CSI/TAC PAN AVAILABItJTY OF ( SIGNAL CONVER EXIST NG 120VAC �S -485 p162 D MAINT ONFI PDU INTEGRATION DIAGRAM RECT. 3 r RECT. 5 . VERIFY ONTROLLER AND :R AT JOBSITE. TABLE - BELDEN NO. JOT T -TAP ALWAYS DAISY CHAIN RATION IN 3/4" C. DR =1 ADDR =2 GRAWP TURE REMOVAL OF (STING 48V. BATTERY 9R INSTALL OF BATTERY A CELLS 121 -240. C1: RECT. RECT. 7 9 FZE RECT RECT. RECT. RECT 4 6 8 10 FUTURE FUTURE PANEL "DP5A'L, PANEL "DP4E�' AT1111 SCALE: 1/4" = 1' -0" I 2 L B &B ELECTRONICS RS -232 TO RS.485 CONVERTER CVT•2 NEW PDU 145.16 DR =1 ADDR =2 ADDR =3 ABLE - BELDEN NO. NOT T -TAP ALWAYS I DAISY CHAIN ) (RATION IN 3/4" C. FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A EXI STI N BUILpIN 1 SYSTEM DCGB -2 CRAG #27 DSB1 31,:13,35 PIN NO.1 2 3 4 5 6 6 7 a 9 B &B ELECTRONICS RB232/RE485 CONVERTER 485TBLED WITH EXTERNAL POWER SUPPLY 485P62 (NO ECHO & RIB CTRL) RS-485 CONVERTER ROOM FUTURE UPS 5A 500 KVA NEW UPS 213 500 KVA 0.9 PF FUTURE UPS 3A 500 KVA CSI /TAC AUTOMATION CONTROL PANELS BRGB -1 ❑ ❑ ❑ isra I dEY u'8 !litl tJ YkE fall LEI EA Lu ifa Ea C91 ra Ea EA 5J Ad Ed El a) 19 311 d.6 6EU d.S Eu Cc! &i "Y' [1d 514 NE EN LEI IA Ell LW i{19 CA 3R NE IC! ME aCl Nil LEI Olt ME Eta ME NA NG EA NCI Al Ya[ Ri ULE LIE 01 011A Ur9 GB ita tlGi EA INI INi AEI EA GUI al 'MIT LN uld tEd NCE 04 kbl IEB Y'7 YAP AGB� REFER TO SHEET E -4 FOR CONTINUATION PARTIAL FIRST FLOOR PLAN -POWER ROOM ELECTRICAL MAINTAIN POLARITY TX PAIR SHOULD BE TWISTED TOGETHER, RCV PAIR LIKEWISE. USE SHIELD FOR GROUND. D825 MALE R6445 TRUNK TD(A) TD(B) RD(A) RD(B) GND +12VD c J6 RX- RX+ TX- TX+ GND PDU POWER ROOM J7 RX- RX+ TX- TX+ GND CRAC #28 DSA1 25,27,29 J6 RX- RX+ TX- TXF GND PDU J7 RX- RX+ TX- TX+ GND eurigcitr iffau fiffif+ NEW CONC. PAD. I REFER TO DETAIL. BATTERY ALARM/ 1 CONTROL CIRCUIT -I 7" 7" PDU REMOTE COMMUNICATIONS TRUNK CONNECTIONS, J6 AND J7 AT CONTRACTOR BOARD INSIDE PDU. TO NEXT PDU'S SEE DETAIL, THIS SHEET GROUND TERMINATED ONLY AT MIG AND LAST PDU 2 PDU SEPoALINTERFACE �os�A�E v ---- CS /TAC UPS INTEGRATION IN 3/4" CONDUIT - REFER TO DETAILS ON E -12. 1 -3/0 GND. IN 2 "C. (PVC) TO BATTERY ROOM GND. BAR (BRGB -1). D'CGB - -FGB -1 RECT. 9 7 BATTERY 2B DISCONNECT 480V. DC, 1200A. REFER TO DC DRAWINGS. RECT. 1 RECT. 5 RECT. RECT. RECT. RECT. RECT. 10 8 6 4 2 ANALA ER ZONE 3 BOX mV (n (NI N D- y- w z mw U 0 2 w W Ce U I 1 FUTURE 1 NEW PANELBOARD 1 PANEL "DP3A'k "DP2E " I NO SCALE ❑ E FUTURE BATTERY 3B DISCONNECT 480V. DC, 1,200A r PANE "CRPPJ _ PDU DATA POINTS 6 EXISTING TERM. PLANT #2 STRIN #3 1 ROW, 2 TIER -24 BATTERY EXISTING TERM. PLANT #2 STRING #4 1 ROW, 2 TIER -24 BATTERY r CityafTukwila IIDING DIVISION EXTEND NEW TELEPHONE CABLE IN 3/4" CONDUIT TO TELEPHONE SYSTEM LOCATED ON MEZZANINE FLOOR. ROUTE CONDUIT OUTSIDE NEW EQUIPMENT ROOM. REVIEWED FOR CODECOMPLIANCE NFPA10- FEB 11 2UO9 FUTURE UPS BATTERY 3A CELLS 1 -240 EXISTING WALL MOUNTED TELEPHONE. E1.0 010 1 r 2 W z ,, - "I I< MATCHLINE EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL. INDEX 26 27 28 29 32 33 34 35 36 KVA C NAME ANALOG DATA POINTS TYPE 16 BIT INTEGER THD C 16 BIT INTEGER TOTAL KVA 16 BIT INTEGER FREQUENCY 16 BIT INTEGER PERCENT KVA A 16 BIT INTEGER PERCENT KVA B 16 BIT INTEGER PERCENT KVA C 16 BIT INTEGER KWH 16 BIT INTEGER PF C 1 16 BIT INTEGER SCALE NONE NONE NONE *10 NONE NONE NONE HIGH WORD LOW WORD 5 =5% NOTE 600 -60 HZ 75 =75% 75 =75% 75 =75% KWH IS A 32 BIT UNSIGNED INTEGER DIVIDED INTO (2) 16 BIT INTEGERS RECEIVED CITY OF TLJ WILA FEB 0 5 log ly PERMIT CENTER WTA - 08093 COPYRIGHT 02009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 1 D t' o '''M W I- U' g• j") N - % O W k W ' o big >AJ W"' n ZWN O Q3 z kft LD (f) 1 w U) cf) cb cif) Fac. COde:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Praj. Mgr.: KCM Date: 12-12-08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02-02 -09 100% CD Project No. WTA. 08093 Sheet No. E -5 95% REVIEW ADD. NO. 1 PERMIT SET PARTIAL FIRST FLOOR PLAN - POWER ROOM, ELECTRICAL 1 � GFI WP E EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER -24 BATTERY MATCHLINE r FUTURE UPS BATTERY 5A CELLS 1 -240 EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. 1 r l : ❑ EXISTING CSI IN EX ST. EN-23-� I_ PAIR. LEO NO SCALE FUTURE BATTERY 5B DISCONNECT --- 480V., DC, 1200A 401 A1111 N2 TRUNK IN FROM CSI ❑ CSI/rAC BATTEITY BATTERY a JU UBLE UABLE D LED (SET TO ENABLE) PORT P� P1R &211 Pail &222 PJFM-131 PDI POWERPAK C6. SPDB #1 4 "x4" COLUMN (TYP. THIS ROOM) SPDB #1 TX-n RCn B &8 ELECTRONICS RS -232 TO R8-085 CONVERTER CVT -1 MPDB RE( 1 EX. CSI/TAC PAN AVAILABItJTY OF ( SIGNAL CONVER EXIST NG 120VAC �S -485 p162 D MAINT ONFI PDU INTEGRATION DIAGRAM RECT. 3 r RECT. 5 . VERIFY ONTROLLER AND :R AT JOBSITE. TABLE - BELDEN NO. JOT T -TAP ALWAYS DAISY CHAIN RATION IN 3/4" C. DR =1 ADDR =2 GRAWP TURE REMOVAL OF (STING 48V. BATTERY 9R INSTALL OF BATTERY A CELLS 121 -240. C1: RECT. RECT. 7 9 FZE RECT RECT. RECT. RECT 4 6 8 10 FUTURE FUTURE PANEL "DP5A'L, PANEL "DP4E�' AT1111 SCALE: 1/4" = 1' -0" I 2 L B &B ELECTRONICS RS -232 TO RS.485 CONVERTER CVT•2 NEW PDU 145.16 DR =1 ADDR =2 ADDR =3 ABLE - BELDEN NO. NOT T -TAP ALWAYS I DAISY CHAIN ) (RATION IN 3/4" C. FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A EXI STI N BUILpIN 1 SYSTEM DCGB -2 CRAG #27 DSB1 31,:13,35 PIN NO.1 2 3 4 5 6 6 7 a 9 B &B ELECTRONICS RB232/RE485 CONVERTER 485TBLED WITH EXTERNAL POWER SUPPLY 485P62 (NO ECHO & RIB CTRL) RS-485 CONVERTER ROOM FUTURE UPS 5A 500 KVA NEW UPS 213 500 KVA 0.9 PF FUTURE UPS 3A 500 KVA CSI /TAC AUTOMATION CONTROL PANELS BRGB -1 ❑ ❑ ❑ isra I dEY u'8 !litl tJ YkE fall LEI EA Lu ifa Ea C91 ra Ea EA 5J Ad Ed El a) 19 311 d.6 6EU d.S Eu Cc! &i "Y' [1d 514 NE EN LEI IA Ell LW i{19 CA 3R NE IC! ME aCl Nil LEI Olt ME Eta ME NA NG EA NCI Al Ya[ Ri ULE LIE 01 011A Ur9 GB ita tlGi EA INI INi AEI EA GUI al 'MIT LN uld tEd NCE 04 kbl IEB Y'7 YAP AGB� REFER TO SHEET E -4 FOR CONTINUATION PARTIAL FIRST FLOOR PLAN -POWER ROOM ELECTRICAL MAINTAIN POLARITY TX PAIR SHOULD BE TWISTED TOGETHER, RCV PAIR LIKEWISE. USE SHIELD FOR GROUND. D825 MALE R6445 TRUNK TD(A) TD(B) RD(A) RD(B) GND +12VD c J6 RX- RX+ TX- TX+ GND PDU POWER ROOM J7 RX- RX+ TX- TX+ GND CRAC #28 DSA1 25,27,29 J6 RX- RX+ TX- TXF GND PDU J7 RX- RX+ TX- TX+ GND eurigcitr iffau fiffif+ NEW CONC. PAD. I REFER TO DETAIL. BATTERY ALARM/ 1 CONTROL CIRCUIT -I 7" 7" PDU REMOTE COMMUNICATIONS TRUNK CONNECTIONS, J6 AND J7 AT CONTRACTOR BOARD INSIDE PDU. TO NEXT PDU'S SEE DETAIL, THIS SHEET GROUND TERMINATED ONLY AT MIG AND LAST PDU 2 PDU SEPoALINTERFACE �os�A�E v ---- CS /TAC UPS INTEGRATION IN 3/4" CONDUIT - REFER TO DETAILS ON E -12. 1 -3/0 GND. IN 2 "C. (PVC) TO BATTERY ROOM GND. BAR (BRGB -1). D'CGB - -FGB -1 RECT. 9 7 BATTERY 2B DISCONNECT 480V. DC, 1200A. REFER TO DC DRAWINGS. RECT. 1 RECT. 5 RECT. RECT. RECT. RECT. RECT. 10 8 6 4 2 ANALA ER ZONE 3 BOX mV (n (NI N D- y- w z mw U 0 2 w W Ce U I 1 FUTURE 1 NEW PANELBOARD 1 PANEL "DP3A'k "DP2E " I NO SCALE ❑ E FUTURE BATTERY 3B DISCONNECT 480V. DC, 1,200A r PANE "CRPPJ _ PDU DATA POINTS 6 EXISTING TERM. PLANT #2 STRIN #3 1 ROW, 2 TIER -24 BATTERY EXISTING TERM. PLANT #2 STRING #4 1 ROW, 2 TIER -24 BATTERY r CityafTukwila IIDING DIVISION EXTEND NEW TELEPHONE CABLE IN 3/4" CONDUIT TO TELEPHONE SYSTEM LOCATED ON MEZZANINE FLOOR. ROUTE CONDUIT OUTSIDE NEW EQUIPMENT ROOM. REVIEWED FOR CODECOMPLIANCE NFPA10- FEB 11 2UO9 FUTURE UPS BATTERY 3A CELLS 1 -240 EXISTING WALL MOUNTED TELEPHONE. E1.0 010 1 r 2 W z ,, - "I I< MATCHLINE EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL. INDEX 26 27 28 29 32 33 34 35 36 KVA C NAME ANALOG DATA POINTS TYPE 16 BIT INTEGER THD C 16 BIT INTEGER TOTAL KVA 16 BIT INTEGER FREQUENCY 16 BIT INTEGER PERCENT KVA A 16 BIT INTEGER PERCENT KVA B 16 BIT INTEGER PERCENT KVA C 16 BIT INTEGER KWH 16 BIT INTEGER PF C 1 16 BIT INTEGER SCALE NONE NONE NONE *10 NONE NONE NONE HIGH WORD LOW WORD 5 =5% NOTE 600 -60 HZ 75 =75% 75 =75% 75 =75% KWH IS A 32 BIT UNSIGNED INTEGER DIVIDED INTO (2) 16 BIT INTEGERS RECEIVED CITY OF TLJ WILA FEB 0 5 log ly PERMIT CENTER WTA - 08093 COPYRIGHT 02009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 1 D t' o '''M W I- U' g• j") N - % O W k W ' o big >AJ W"' n ZWN O Q3 z kft LD (f) 1 w U) cf) cb cif) Fac. COde:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Praj. Mgr.: KCM Date: 12-12-08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02-02 -09 100% CD Project No. WTA. 08093 Sheet No. E -5 95% REVIEW ADD. NO. 1 PERMIT SET PARTIAL FIRST FLOOR PLAN - POWER ROOM, ELECTRICAL GFId-bWP EXISTING 5,000 GALLON DIESEL TANK SCALE: 1/4" = E\CLO St! RE 4 . a a EXISTING 5A. DIESEL 4 00 GAI_L N TANK EXISTING GENERATOR 2500KV /2000K A 277V/48 V. 30, 4 4 EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEI)1 FROM THE OWNER'S RECORD DRAWINGS AND/OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NE1ITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXITING CONDITIONS FROM THAT INDICATED ON THE DRAVVINGS COULD IN ALL PritOBASILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSA Y TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT/ENGINEER OF ANY DISCREPANCI S PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBI 4TY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AN CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. ELECTRICAL ENCLOSURE SF R EXIST. UTIL XFMR PARTIAL FIRST FLOOR PLAN — ELECTRICAL. ROOM AND COURTYARD, ELECTRICAL . -A- -X X - , , X- -X-- -X - FUT. UTIL XFMR #2 PAD PIPE COVER C RAC #30 DSB1 37,39,41 L PANE . 'ULPP1-1" I I_ IA Z 7 I X LITHONIA LIGHTING <1 I CONTROLLER- L . E k C (: : :: T c R w le i EC ROOM MOUNTED TELEPHONE. • XFMR '.UTRL1-1 EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL PANEL "LPPA XFMR TRLA1 NEW FEEDER BRKR. FOR PDU 166.01 REFER TO ONE-LINE DIAGRAM EXTEND NEW TELEPHONE CABLE IN 3/4"C. TO EXISTING TELEPHONE SYSTEM ON MEZZANINE FLOOR. ROUTE CONDUIT OUTSIDE NEW EQUIPMENT ROOM. EXIST. "MDSB" EXIST. "MDSA" MDS-SIDE B (109) MAIN BREAKER MDSB (108) TIE BREAKER (107) MAIN BREAKER MDSA MDS-SIDE A (105) (104) (103) (102) DIST. PNL "UPP'I" — NEW CKT. BRKR. MDSB-110E FOR UPS 2B PRIMARY INPUT REFER TO ONE- LIN E DIAGRAM NEW CKT. BRKR. MDSA-103D FOR UPS 2B BY-PASS REFER TO ONE- LINE DIAGRAM . • 01,...,1. BATTERY 1D BATTERY IC BATTERY 19 EXISTING WALL REFER TO SHEET E-4 FOR CONTINUATION BATTERY 1A UPS-1 EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL. 1 1 IEWED FOR-- CODE COMPLIANCE NFPA 70 - NEC i-td / 1 . iuud 'Citytr „3).#011kaig II e .--- 4,41 M tr! E.1.4 1.11 414 EA lat all 14 AI 1411 MIA h di ileatil VA rig lks U a :At 44 go a; Ill VI 44 1410i 1 Y4.1 44 WA 40 141114 MO MAW *I 44 4 .4J aid LE 4.11 4;44 .Al 1444 4441 4 4.4 E Lo o '11 "'EXISTING WALL MOUNTED PHONE. - ALJTOSTICK II -POWER 'MACK 9000 POVVER MONITORING INTERFACE "URDP1-3" . 7 MATCHLINE RECEIVED CITY OF TUKWIUk FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS t io • \ L c o 42559 / 7_2 ..1 17 [ 'r-2(-;1 2 3 01-05-09 01-15-09 01-26-09 02-02-09 Fac. Code:TYKWWA Drawn By IM, PS, ZJ NEW AMININIMINIMMIIMMIMMUMMIIMIME18011116111W Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12-12-08 Revision 100% CD Project No. WTA. 08093 Sheet No. E-6 95% REVIEW ADD. NO. 1 PERMIT SET PARTIAL FIRST FLOOR PLAN - ELECTRICAL ROOM AND COURTYARD, ELECTRICAL X )E X X )E )E )E 3C 3E X X X X X )E X X )E X 't( X. X }4....)E- ':( )h.....)E..- ,{_.... 3 EXISTING 5,000 GALLON DIESEL TANK SCALE: 1/4" = 1' -0" 1. G NER.A,TOR ENCLOSURE. EXISTING CONDITIONS NOTE: 4 a • 4 3 ° 4 a d 4 EXISTING 5 000 GA DIESE_ TANK -X- ); .._.X_....-X- -X-- - -X -_ X- C)N EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED Tp THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NE THER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLI1JTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXITING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PFOBABI OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE J B SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSA Y TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCI PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS ANI1 CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONA4COS TO THE OWNER OR ARCHITECT /ENGINEER. a ELECTRICAL ENCLOSURE IRA EXIST. UTIL XFMR #1 - -Xc PARTIAL FIRST FLOOR PLAN — ELEQTRIQAL ROOM AND COURTYARD ELECTRICAL FUT. UTIL XFMR #2 PAD z -1 ;x t LITHONIA LIGHTING I CONTROLLER I I.. yI:; I ---.. -- .- -�LEC. ROOM NEW FEEDER BRKR. FOR PDU 166.01 REFER TO ONE -LINE DIAGRAM BATTERY 1D EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL. PANEL "LPPA1" BATTERY IC EXTEND NEW TELEPHONE CABLE IN 3/4 "C. TO EXISTING TELEPHONE SYSTEM ON MEZZANINE FLOOR. ROUTE CONDUIT OUTSIDE NEW EQUIPMENT ROOM. DIST. PNL "UPP1" EXIST. "MDSE" EXIST. "MDSA" UPS1 BY -PASS BATTERY '1 B EXISTING WALL REFER TO SHEET E -4 FOR CONTINUATION MOUNTED TELEPHONE. (113) (112) (110) MDS -SIDE B (109) MAIN BREAKER MDSB (108) TIE BREAKER (107) MAIN BREAKER MDSA (106) ......... MDS -SIDE A (105) (104) (103) (102) (1 BATTERY IA f.. r?: u (t. I( . 4. „: a r / / NEW CKT. BRKR. MDSB -110E FOR UPS 2B / PRIMARY INPUT REFER TO ONE- / LINE DIAGRAM NEW CKT. BRKR. MDSA -103D FOR UPS 2B BY -PASS REFER TO ONE- LINE DIAGRAM XFMR PANEL _._... ......_ _.UTRL-1 ULPP'I 1” ;00 30 011 0A11 Al 4 VA 310 311 3:: 001 131 33 114 33 303 N7 133 30.4 'a3 hilt VS 030 152 still '/E! 43 31 '033 ilia 301 36 33 !S 34 33H 3iG t03 013 V31 101 9:A 001 gal EI3 030 33 WI 334 1'15 133 13 3'A 147 43 33 V.1". 413 43 l'31 4i Lill 137 1,1 310 a 303 303 41 UPS -1 EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL. 2 ELOoiO 1 " EXISTING WALL MOUNTED PHONE. —AUTOSTICK II POWER TRACK 8000 POVVER MONITORING INTERFACE —M SGB SEWED FOR CODE COMPLIANCE PPA - NEC PANEL URDP1 -3" MATCHLINE i'Lt 11 4uud cityorrukwita DstON RECEIVED CITY OF TUKWILA FEB B 5 2009 PERMIT CENTER WrA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS • 3 1 E- 1 0 la t • 0 0011 • Ifigq Z ' ' ' m N rn M i I0Wk. W' 0 M0 Q Wo i- 7' J W"s Z mI Q O .2 1 # mow e " Expires 7/+ co c (i) (D wc (f) cic (NI Fac. Code :TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision ■4 r 01 -05-09 95% REVIEW 2 01-15-09 100% CD 3 01 -26 -09 ADD. NO. 1 02-02-09 PERMIT SET Project No. WTA, 08093 Sheet No. PARTIAL FIRST FLOOR PLAN - ELECTRICAL ROOM AND COURTYARD, ELECTRICAL EXISTIh G GEN . .,-----1.-1,---- .,-----1.-1,---- • BATOR 1 = M , ' 1 � „An] - in ! Ul ON E(F,3iw II a 277 V. 30, 0 VU W rIi1 I. 41 1 t; - --- --_.-ri , _, — X )E X X )E )E )E 3C 3E X X X X X )E X X )E X 't( X. X }4....)E- ':( )h.....)E..- ,{_.... 3 EXISTING 5,000 GALLON DIESEL TANK SCALE: 1/4" = 1' -0" 1. G NER.A,TOR ENCLOSURE. EXISTING CONDITIONS NOTE: 4 a • 4 3 ° 4 a d 4 EXISTING 5 000 GA DIESE_ TANK -X- ); .._.X_....-X- -X-- - -X -_ X- C)N EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED Tp THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NE THER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLI1JTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXITING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PFOBABI OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE J B SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSA Y TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCI PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS ANI1 CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONA4COS TO THE OWNER OR ARCHITECT /ENGINEER. a ELECTRICAL ENCLOSURE IRA EXIST. UTIL XFMR #1 - -Xc PARTIAL FIRST FLOOR PLAN — ELEQTRIQAL ROOM AND COURTYARD ELECTRICAL FUT. UTIL XFMR #2 PAD z -1 ;x t LITHONIA LIGHTING I CONTROLLER I I.. yI:; I ---.. -- .- -�LEC. ROOM NEW FEEDER BRKR. FOR PDU 166.01 REFER TO ONE -LINE DIAGRAM BATTERY 1D EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL. PANEL "LPPA1" BATTERY IC EXTEND NEW TELEPHONE CABLE IN 3/4 "C. TO EXISTING TELEPHONE SYSTEM ON MEZZANINE FLOOR. ROUTE CONDUIT OUTSIDE NEW EQUIPMENT ROOM. DIST. PNL "UPP1" EXIST. "MDSE" EXIST. "MDSA" UPS1 BY -PASS BATTERY '1 B EXISTING WALL REFER TO SHEET E -4 FOR CONTINUATION MOUNTED TELEPHONE. (113) (112) (110) MDS -SIDE B (109) MAIN BREAKER MDSB (108) TIE BREAKER (107) MAIN BREAKER MDSA (106) ......... MDS -SIDE A (105) (104) (103) (102) (1 BATTERY IA f.. r?: u (t. I( . 4. „: a r / / NEW CKT. BRKR. MDSB -110E FOR UPS 2B / PRIMARY INPUT REFER TO ONE- / LINE DIAGRAM NEW CKT. BRKR. MDSA -103D FOR UPS 2B BY -PASS REFER TO ONE- LINE DIAGRAM XFMR PANEL _._... ......_ _.UTRL-1 ULPP'I 1” ;00 30 011 0A11 Al 4 VA 310 311 3:: 001 131 33 114 33 303 N7 133 30.4 'a3 hilt VS 030 152 still '/E! 43 31 '033 ilia 301 36 33 !S 34 33H 3iG t03 013 V31 101 9:A 001 gal EI3 030 33 WI 334 1'15 133 13 3'A 147 43 33 V.1". 413 43 l'31 4i Lill 137 1,1 310 a 303 303 41 UPS -1 EXISTING TELEPHONE CABLE AND 3/4" CONDUIT THRU NEW EQUIPMENT ROOM SHALL BE REMOVED. PATCH WALL. 2 ELOoiO 1 " EXISTING WALL MOUNTED PHONE. —AUTOSTICK II POWER TRACK 8000 POVVER MONITORING INTERFACE —M SGB SEWED FOR CODE COMPLIANCE PPA - NEC PANEL URDP1 -3" MATCHLINE i'Lt 11 4uud cityorrukwita DstON RECEIVED CITY OF TUKWILA FEB B 5 2009 PERMIT CENTER WrA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS • 3 1 E- 1 0 la t • 0 0011 • Ifigq Z ' ' ' m N rn M i I0Wk. W' 0 M0 Q Wo i- 7' J W"s Z mI Q O .2 1 # mow e " Expires 7/+ co c (i) (D wc (f) cic (NI Fac. Code :TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision ■4 r 01 -05-09 95% REVIEW 2 01-15-09 100% CD 3 01 -26 -09 ADD. NO. 1 02-02-09 PERMIT SET Project No. WTA, 08093 Sheet No. PARTIAL FIRST FLOOR PLAN - ELECTRICAL ROOM AND COURTYARD, ELECTRICAL ---- EXISTING GROUNDING TEST WELL �,�— EXISTING 4/0 BARE 7 STRAND BURIED GROUND LOOP EXISTING CHILLED WATER PUMP P1— EXISTING P1 DISC— EXISTING P2 DISC- EXISTING CHILLED WATER PUMP P2 MCCA -3 NEW CHILLED WATER PUMP 3-08 DISCONNECT NEW CHILLED WATER PUMP 3-08 "MCC MCCB" "MCCA" ROOM SCALE: 14" =1 EXISTING A COOLED CHI LER 1 EXISTING CONTROL INTERFACE RDPAI-41 RDPA1 -39 GI-- ILL.E.-R , 1 AR[) NEW FREEZE PROTECTION HEAT TAPE - CHILLED WTR SUPPLY NEW FREEZE PROTECTION HEAT TAPE - CHILLED WTR RETURN EXISTING JANITOR SINK — EXISTING GLUCOL FEED UNIT GF -1 ' EXISTING CHEMICAL POT FEEDER EXISTING EXPANSION TANK CONNECT NEW CHILLER GROUND TO EXISTING GROUND LOOP GROUND ROD AT THIS HANDHOLE E}CISTINGGRO ND'• • Ff O}VI CHILLER ; '-� . EXISTING AIR COOLED CHILLER 2 -BOLT #6 GROUND TO NEW CHILLER FRAME LEG AND EXTEND TO EXISTING BURIED GROUND LOOP cr-- C.B. BMS NETWORK INTERFACE CIRCUIT IN EXISTING CONDUIT 1 <, I t P - • I "-- EXISTING 1 -1/2 "C MDSA -104D CHILLER STARTER AND DISCONNECT PROVIDED WITH UNIT NEW AIR COOLED CHILLER 3-08 PARTIAL FIRST FLOOR PLAN — CHILLER YARD AND PUMP ROOM ELECTRICAL, POWER EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. NOTES INDICATED BY NUMBER IN 1. PROVIDE NEW 30A, 1 -P, 120V. CIRCUIT BREAKER IN EXISTING PANEL. VERIFY CIRCUIT NUMBER AND SPACE AVAILABILITY AT JOB SITE. CIRCUIT SHALL SERVE NEW FREEZE PROTECTION HEAT TAPE. 2. NEW CIRCUIT SHALL BE INSTALLED IN EXISTING UNDERGROUND CONDUIT(S). VERIFY LOCATION OF CONDUIT(S) AT JOB SITE. 3. NEW DISCONNECT SHALL BE 30A, 3 -POLE, 480V., NEMA 1 NO -FUSE. ELO9 101 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC f 11 tuut City0iTukwila 1 1 RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 3 1 Der. Dom rl W� �it I- Mat 3 to w 410 f W o &G w W f w y 0 Z >J o W ZmN o 4M Expires 9- /l1? I szo h E -7 co ur) cf) u.1 "cc vriN c'4 Fac, Code :TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12-12-08 Revision 1 01 -05 -09 95% REVIEW 2 01 -15 -09 100% CD 3 01 -26 -09 ADD. NO. 1 4 02 -02 -09 PERMIT SET Project No. WTA. 08093 Sheet No. PARTIAL FIRST FLOOR PLAN - CHILLER YARD AND PUMP ROOM, ELECTRICAL, POWER LIGHTING FIXTURE SCHEDULE MARK MANUFACTURER & CAT. NO FIXTURE TYPE MOUNTING LAMP & TYPE REMARKS VOLTAGE E SURE LITES CX- 7- 1- 70 -R -W LED EXIT SURFACE LED EXIT -RED - 2.9W NOTES 3,4 277 EXISTING FIXTURE INFORMATION - COLUMBIA RO- 4- 2- 32- EB8-277 -EL FLUORESCENT SUSPENDED (2) 32W T8 - PRISMATIC NOTE 1 277 - COLUMBIA RO- 4- 2- 32 -EB8- 277 -EL (EMERGENCY FIXTURE) FLUORESCENT SUSPENDED (2) 32W T8 - PRISMATIC NOTE 2 277 MATCHLINE EXISTING CONDITIONS NOTE: GENERAL NOTES: 'rir Adr4 EXISTING EQUIPMENT ROOM O 0 -5/;/ / / //i �. / f 10M1111 NEW EXIT LIGHT ON WALL 0 i/ b 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF EXISTING CONDITIONS FROM THAT INDICATED N T TH E _ S C THE ON H DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. 1. ALL NEW AND EXISTING CONDUITS PENETRATE NEW WALL SHALL BE INSTALLED OR RETROFITED WITH PLASTIC COUPLER AS SHOWN ON DETAILS 3 AND 5 ON SHEET E -17. _., 7 I ,.,• „k7 MP 1. F, 144.02 144.03 /7/ it 142.02 142.03 142.04 142.0 REFER TO E -9 FOR CONTINUATI N C)- DA II grad ��ow cwt ,tilr.. a:a e3o: n'SV iwli 1 , ... 145.05 145.06 145.07 dV.2111kati: J .\tl s /// 144.04 144.05 144.06 144.07 144.08 I I♦ Ixu,rPY' �a.r r,Jwrrlr ,ur . 11.111•1 ' �43 05 1L13 07 143 08 �, W us. Wd 1M'tskruh:aaiu,.na�t »,�4..a,4. rs /// AL .k ..,:.» .7.In;r �. v ✓r7d.: 142.06 142.07 142.08 144.09 1-- P`1 1 /7/ ' 16 . J'L 6'J t)' • a dM'U.1 ttR /fl - ".:� , :,1 .Y�60 ,f;n leaa / / />/ : / 1 ? ,11✓di Af[ 41t1{i .J: ' Yl4 +P 144.10 144 1 1413 09_ 1„ .2 113 1l 14 �2- 1413 ' i.tlbJ IYut +.v�.Atl: U :Ud., b,LL A4L�{5f Ib,.u�,d�;,dMi„tn,: [., 6166 fa.➢rk.4P,A..Y f ,y„51C aGmS nxC4�6iC1 • : Ike ...IrJ 1 0011• '11414 t ?Nd yiM Tit /f Car SCALE: 1/4" =1"-W b C) Y ' / 14\6 iL r' I r1 IHH L"l5 V'f Vlkl tMV. �H4 //! I I h '�1.Ciw, ,1 „6rF1 t.:'.1i1>I af...d'F LIu•(1�..P' 1 44.12 144.13 '144.14 144.15 144,16 144.17 '144.18 143.15 143.16 143.17 143.18 / STHw'�71 y1t 1.60, 111:4' 1 &1,,.1J5 u':b'.i1 aS.11llAi11 A4A IfYl,kd'In L. i4' U':, d:,:, '^n{. "uG.Y..Gilik:b.IP5t161uaRG "..;4141 „I.. ',f,.'i" AL.... 142.09 142.10 142.11 142.12 '142.13 142.14 142.15 142.16 142.17 142.18 • 0 4 p r §1 � 3. EXTEND NEW LIGHTING I- IOMEFUN IN CONDUIT THRU ISOLATION COUPLING AT NEW EQUIPMENT ROOM WALL. REFER TO DETAIL 5, SHEET E -' 7 FOR CONDUIT PENETRATION THRU WALL DETAIL. 4. EXTEND SWITCHING W1 ES FCR SWITCHING DESIGNATION "b" IN CONDUIT TO BACK TO SWITCH BANK INSIDE EQUIPMENT ROOM. REF R TO r ECURITY ROOM DETAIL SHEET E -9 FOR EXTACT LOCATION OF SWITCH. 5. EXTEND SWITCHING WI ES FCR SWITCHING DESIGNATION "d" IN CONDUIT TO BACK TO SWITCH BANK INSIDE EQUIPMENT ROOM. REF R TO SECURITY ROOM DETAIL SHEET E -9 FOR EXTACT LOCATION OF SWITCH. 6. CONNECT 3- #12'S, 1 - #12 bND, IN 3/4" C. FROM NEW EXIT LIGHT TO EXISTING EMERGENCY FIXTURE SHOWN. 7. EXISTING LIGHTING FIXTURES AND ASSOCIATED CIRCUITING SHALL BE RELOCATED 1' NORTH OF CURRENT LOCATION TO ALLOW FOR NEW WALL CONSTRUCTION. 8. EXISTING SWITCHBANK O BE REMOVED PRIOR TO NEW WALL CONSTRUCTION. CONTRACTOR SHALL REMOVE ALL ASSOCAITED WIRIN FROM SWITCHBANK BACK TO SOURCE. THESE SWITCHES CURRENTLY CONTROL LIGHTS IN EQUIPMENT ROOM VIA LIGHTING CONTACTORS IN EXISTING LIGHT CONTROL PANEL. 15 NOTES INDICATED BY N MBER IN : 1. CONDUCTORS, WIREWAYS AN ALL ASSOCIATED CIRCUITING TO BE REMOVED BETWEEN TWO FIXTURES T U S O ALLOW FOR NEW WALL ONST UCTION. 2. CONDUCTORS, WIREWA S, AN ALL ASSOCIATED LIGHTING CIRCUITING FROM LIGHT CONTROL PANEL SHALL BE REMOVED BETWEEN JUN TION BOXES TO CREATE NEW SWITCHING CIRCUIT. 1 a ca 1 1 / .. i:C: ti :�: : ::TL :w :: G: : SCw ::. uw 1[ �: l L__._� �._,_CI..w..:: C .�_ . .rL' •._..._.. : "�: 0 LPPA1 -10 LPPA1 } 0 1, d d d d Aelv 0 /// DOI NEW E0 d1I'IVIE:N_f /// 1419 / unarfi ^ia zr�,mu�.>r�cr:,u,uud 1r, - �u�. 1J'1]L".lu0 D r !L+_: S3 Mgr P 1 1 1 .I , 1 C!1 I , l l Ii f ! 111 SVPI VbV .ti �IP.N3.1" YZ'I yy UI�iPil V.Q bJ. dJ NJp M. qx ti c' .. m � 11.00..$ m J nr. t.1 ..9�2 ' d. 165.0'1- - - °165.02 _ _.165,03. pro • • o f� t // tit d ,k4.4kJ La ?al ir. l4 ,uk • YX •.s /.4 Ut • ,P t 7. aNdr�3rY8 +a it'. 021Aw,a(m +1t. xua[ Ladd ,J,'Jj' . !33e3W..roiru 167.01 167.02 167.03 167.04 167.05 167.06 167.07 166.03 166.04 166.05 166.06 [•Y.Ik.V:C.S:Pd:'C`d,b. F. 1,S.I.Yi,.ik, 4t�8N'dl.t J:H:tY7'a9k.tA.VGF;PA "k G.i�l':J..1L,ie @11lLLi6H'. d ¢t'GJaii%:rf�l `x ',"R34i43IM,1 3i i .4'mJ,/,,iil,3 A 9t1C'9i4LC Wk'N.L rV:l, 165.04 _. 165.05_ _165.06_.. 165.07_. • • • i /7/ rti 1Y ",1 ,r 1 , ll,l .I: E: :s .ti='rr __e _ :m _ : rl____ : __ � _� trc:.: PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING -SOUTH FIXTURE SCHEDULE NOTES: 1. 6 "x4' FLUORESCENT FIXTURE, SLIM LOW PROFILE HOUSING. PRISMATIC ACRYLIC DIFFUSER. MOTOROLA RAPID START ELECTRONIC BALLAST, <10% THD. RFI SUPPRESSION 6 "x4' FLUORESCENT FIXTURE, SLIM LOW PROFILE HOUSING. PRISMATIC ACRYLIC DIFFUSER. MOTOROLA RAPID START ELECTRONIC BALLAST, <10% THD. RFI SUPPRESSION. PROVIDE EMERGENCY BATTERY PACK WITH MINIMUM OF 5 YEAR WARRANTY AND 1350 INITIAL LUMEN OUTPUT. CONNECT UNIT TO TWO LAMPS. PROVIDE BODINE B30 OR EQUAL BY LITHONIA. d d t.11 1,t, ::, A3 u . F { Its D T. it IS ttl it 1 d I d U'e7 A . ,tia .. .'UeMEFk1q.7,. V."_a1A 115ThY..M wx.. u„ � �,. �. vx,.,, a. 5 :kt�ti...dV,iha...4i.a,7J;P,.Ge [I 1.E..,.,I.nhrit6.w;L lruhlYPtki.+.s. G r, um,- u1saarwu3 •itv,aa {,�pV.h,an {,y1�PS. 167.08 167 09 167.10 167.11 167.12 16713 16 14 167.15 167.16 167.17 166.07 166.08 166.09 7A�T•V /.-/ l9eFd: 4W ,,,;rA.lY7R'.:d4:..,r"'F,°d,,; rreR1<FrsV,G1 H: d nsn nwhIIL.L_L3.'uD d •A. f4+ l bt+6. ". t Lb f7,Y Jtw1A iNittullY .10 r: ,,.Utc.12 v;J r4t}N Ybs+' "G T _165.08 _._ . 165.12 165.13 165.14_ EXISTING LIGHT FIXTURES AND WIREWAY SHALL REI1AIN. RE- CIRCUIT TO NEW SWITCH A INDICATED, TYPICAL_ • I ; 12'iY1 hA .1fY r16i't;1 4; REFER TO E -9 FOR CONTINUATION /7/ 166.10 16 ' 6. I 1 >;i6.' 2 1 I 166 13 uM46iSWb Ptd8d2t tilh`dhYd..1Pelhv6Sn �ftilhral ,Il'J'JAx1:,�'7 a,.u1J'JI IllMa /f/ [. 1 fi� ,Ili.N @d .,i tint iEfGl't'Lt1,d,b'IYbS'.,i.�5:2s: EXISTING EMERG. - �� _ LIGHT FIXTURE FED FROM UPS PANEL SHALL REMAIN, TYPICAL 4 _; COM d �� . _e 7 3. EACH FIXTURE SHALL BE EQUIPPED WITH A BATTERY POWER PACK SUITABLE FOR 90 MINUTES OF EMERGENCY POWER. PROVIDE BODINE B30 OR APPROVED EQUAL. 4. EACH FIXTURE SHALL BE DIE -CAST ALUMINUM HOUSING, ALL WHITE FINISH, POLYMERIC DIFFUSER (RED) ARROWS AS INDICATED. yY 2 A'NN /fir 4 d d NEW EXIT LIGHT ON WALL 1 LO9 0101 d MATCHLINE DE VIEWED �pA ©p PaAh NEC ' LLj 1 1 LUI41 'ty Tukwila -DING a srol RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA , 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS t yE) [Expires n zi s:r3ax� G 1 01 -05 -09 2 01 -15 -09 3 01 -26 -09 Lip P!c kSIONAL ,gyp /01 Nam 0 Q) z M i lli geNNEIMMIMMISMINEMEINEINEMINKSVEMIKONINVEMIESIIM Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KGM, DL, ZJ Revision Proj. Mgr,: KM Date: 12 -12 -08 95% REVIEW 100% CD A[)D. NO. 1 4 02 -02 -09 PERMIT SET 3 MATCHLINE 7 PA FUTRE EL "DP4 um. L 1 E,1STINt3 EQtJPMENr ROOM EXISTING CONDITIONS NOTE: GENERAL NOTES: e ) - r - '15f);.01 Main 11MM MIME a 2. REFER TO LIGHTING FIXTURE SCHEDULE SHEET E-8 FOR INFORMATION ON NEW LIGHTING FIXTURES. 1:t EVV SECURITY /7/ 1_ • , O. 4", • E ,•• , 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND/OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. 1. ALL NEW AND EXISTING CONDUITS PENETRATE NEW WALL SHALL BE INSTALLED OR RETROFITED VV1TH PLASTIC COUPLER AS SHOWN ON DETAILS 3 AND 5 ON SHEET E-17. , REFER TO SECURITY ROM SHEET FOR NEW WORK IN T ;16 a 11:././ , tIti. Rh, . )!.• v av ,,, , 150. "160.6'3 " l'):2"U Cr/ • )d); ).)))) ;.''.)'(;) 11.) '1 d.'1. 1 .1): ); 141)) 1.11 d -.:)..1;,) '1.1'.) -.1. 11).1 • 1 1 . Pit* - 1RSI-7,■•14!t• :dtt -11t1 1,21, 0.■ ir tPtt•ttP4 .1P114,11 AR" Rtl•;,tr Rtt 1 REFER TO E-8 FOR CONTINUATION ma v.., di , ./ el, itt,;;,...) 1.1 1 1 `;."' :11 .1 1 FUTURE PANE.. "DP3A , L. .t•J 5. EXISTING LIGHTING H BE REMOVED. RMOV FROM HOMERUN 1 .1-BO PANEL. CONTRACTOR "SPARE" AT EXISTING FIXTURE INSIDE THE N SHALL BE CONTROLLE 6. CONNECT 3-#12'S, 1-#1 FIXTURE IN NEW 3ECU CIRCUIT FOR NE ZON 7. EXTEND SIMTCHIr CONDUIT TO BAC( TO TO SECURITY ROOM D SWITCH. ErTAIL, THIS IS AREA. 4 tot It, ntt tt /R4i RR■t !iv !!!,.! - ;t1 R:k• +et , 1 . •kt n na Sin air 1,,,ttp,13-ppe-APP-1. Ppv tcp,, t ;: NOTES INDICATED BY NUMBER IN 1) NEW PANELBO _ ANALASER ZONE 3 BOX 1Y)1 ,),1)1.1 RD SCALE: 1/4" = , ' "11, 1-.-).) d' . " . ■ 1 " • ), • ., j 1, ) .t ; 1 1 , i';) 11'1 1 1 : i1l. 1 1 1 . , . . . E) 5(1 1;1' 51.. 1 3 11•11.) 1:1 '1 ? .11.). 15 1 1)(i i ........ - - - a 1. EXISTING EMERG. LIGHT FIXTURE FED FROM UPS PANEL SHALL REMAIN, TYPICAL 1 145 ;i 4 1 • ).:'; ;1 . • Itf'i •1;:l':•)) 11 1;11)) 1' :))) Ltd, r.a•WO 4,14 ti■• 1 -Alt IR! 1. CONDUCTORS, VVIREW ' ilYS AND ALL ASSOCIATED CIRCUITING TO BE 1 REMOVED BE EN TWO FIXTURES TO ALLOW FOR NEW WALL CONSTRUCTION. 7ALL ASSOCIATED CONDUIT AND CONDUCTORS BACK TO LIGHTING CONTROL PANEL TO ERU • 0 LIGHTING CONTROL PANEL AND FEEDER HALL UPDATE PANEL SCHEDULE TO SHOW LE LPPA1-3. CONTRACTOR SHALL ENSURE NO EQUIPMENT ROOM OR NEW SECURITY ROOM BY EXISTING LIGHTING CONTROL PANEL. GND, IN 1/2" C. FROM RELOCATED LIGHTING ITY ROOM TO EXISTING UNSVVITCHED POWER 2 LIGHTS OUTSIDE OF NEW EQUIPMENT ROOM. ES FOR SWITCHING DESIGNATION "a" IN AIL THIS SHEET FOR EXTACT LOCATION OF 2. EXISTING LIGHTING FIXTURE TO BE REMOVE TO ALLOW FOR NEW WALL CONSTRUCTION. CONTACTOR SHALL CLEAN AND RE-USE FIXTURE FOR LIGHTING OF NEW SEC RITY ROOM. REFER TO SECURITY ROOM DETAIL FOR NEW WORK f■ND FIXTURE LOCATIONS. 3. CONDUCTORS, VyIREWAYS, AND ALL ASSOCIATED LIGHTING CIRCUITING SHALL BE REMOVED TO ALLOW FOR WALL CONSTRUCTION IN NEW EQUIPMENT AND SECURITY ROOMS. 4. ROOM CONSTRU TION CONTRACTOR SHALL CLEAN LIGHTING FIXTURE EXISTING LIGHTING Fl TURE TO BE RELOCATE TO ALLOW FOR NEW BEFORE REINST LLIN e fIXTURE. REFER TO SECURITY ROOM DETAIL FOR NEW WORK ND F XTURE LOCATIONS. PANEL "CRPPAl" ROOM 0 01) PANEL 'CRPPB1" PANEL - PALE: • "BPPA2" "BPPB2" // LPPA1 -8 -1 ttt tut t.1.< titflati dtt• Itit 00, At l,. ); /7/ 11/i11.' AarA c 1 \ 1 11 ' 1 1 I - ktt ttPb RI PAt 9,1AN at1 ittl ult1 1 1 i L :' 1 JOU . [ I 1 . I 17.'3 1 11.1 ,,11 ra )4...) 7.141 tk 141 4.1,6 14.1 E-) 1'1.))1 m 175 ; 03 . 175.04 NEVV E0011511417:KI- FLOpB g: ...UR • ,.1Rit• Ttt• 1.Thlfllii,l -.S 1 t4t 411 Papp .tpti. 61•;•41 tt-S -it 'RA WA-14.R 171 1111/ (;)12 1/1,1:13 171 ;114 17 '1. C.)'„)); 1 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - NORTH 8. EXTEND SWITCHING WIRES FOR SWITCHING DESIGNATION "c" IN CONDUIT TO BACK TO SWITCH BANK INSIDE EQUIPMENT ROOM. REFER TO SECURITY ROOM DETAIL THIS SHEET FOR EXTACT LOCATION OF SWITCH. 9. EXTEND NEW LIGHTING HOMERUN IN CONDUIT THRU ISOLATION COUPLING AT NEW EQUIPMENT ROOM WALL. REFER TO DETAIL 5, SHEET E-17 FOR CONDUIT PENETRATION THRU WALL DETAIL. 10. EXISTING LIGHTING CIRCUIT FROM LIGHTING CONTROL PANEL. CONTRACTOR SHALL ADD LIGHTING FIXTURES SHOWN ON SHEETS E-8 AND THIS SHEET VVITH SWITCHING DESIGNATION "e" TO THIS LIGHTING CIRCUIT. NO FIXTURE INSIDE THE NEW EQUIPMENT ROOM OR NEW SECURITY ROOM SHALL BE CONTROLLED BY EXISTING LIGHTING CONTROL PANEL. 11. EXISTING EMERGENCY LIGHTING FIXTURE FEEDER CIRCUIT. CONTRACTOR SHALL VERIFY LOCATION AND PROVIDE ISOLATION COUPLING AT NEW EQUIPMENT ROOM WALL. REFER TO CONDUIT PENETRATION THRU WALL DETAIL, SHEET E-17, DETAIL 5. 12. CONNECT 3-#12'S, 1412 GND, IN 3/4" C. FROM NEW EXIT LIGHT TO EXISTING EMERGENCY FIXTURE SHOWN. .1 rier .4141rd • PANEL "ULPP1-1" 1 ANALASER ZON E 4 B04( /i I it?) Of 1 '76.0F3 + '10 ; '& 1;1 '1 /6..J ;1;/ 11 11;1; 'i 1 11" 1;.; nri. id, Lan • kid aide:. irn tlitiin• 12, ir .1. _, . rMu,I4o r l, . ........ i t .1,T1 s. . qtri tto• tst• • •..41 h . .111 l. 1,1 11::. 11).1 I C.' 1 11;110 1lI 1 /)11..) 11111) 11A))) i)11) )0111.' ,•, EXISTING LIGHT 'IXTURES AND W1REWAY S1HALL REMAIN. RE-CIRCUIT TO NEW 1 A.0% 4 0 ;) 1 1 12 ' 11. " 1 1 AS INDICATED, r ni-anian.i.,Ing tin Lin tittl tta-Pia APP: UP, F■t, ,itto 1t1 'IL.t iR4 4a.an an TYPICAL •• - 1:6 .30 Ot 410 03 (1I 173 r) 07 173. D in4 irk in & 414 . ra/ t;i11 h1.11 07 175 08 171"1 17b.12 1;75. 175.11 .! 72 04 /2,0,5 1 . 72,0e, '172 0/ 172 )1A1 1 . U ■ .t2.11 11212 'I 1 3 1 /2, 1.11. 1 /2,11), '1)") 17 .•.4rto rirani aka e& a.5-1..Flialiark.,:o4,4 .).).4 1.4 10 /31 ...;ilut•I'V ON. dtt ;46.• LY -10 ittl•IPOL-1 , Z41, 11), 1214,1.w, !),,, • ni -a •nm 2.41 an aii-viro•aa 1 1 BATTERY ID ••%&t ;k1t Vit , tdil 111 r. W.R.,.11Vt ,i4 ihiri 1ra a)+, I 71 07 1 71 .()))1 1'71.0131 / 1 lc, '; - ) 1 71 REFER TO /// 173 LIGHT SWITCHES FOR NEW EQUIPMENT ROOM BATTERY IC 0 ro ti!.! if • t i IS I 1 C)1 1)) . 117 1/1 • )1")- 17'1 'Idl I ","'" 1)';■ E-8 FOR CONTINUATION BATTERY la BATTERY 'IA 0 7/w;o/moo/ Ardi , hi) 11) 1 M ) );A 1 ..; . 1 )'/;;;;' . SECURITY f:ZOOJVI /// // SCALE: 1/4" = 1'-0" 114 sit: LW .0 VW Et tg, tRt 11 - ) 1 );3 - 171 17 1/1 I si c c UPS-1 REUSE EXISTING FIXTURES T1 ■I=1. tip :man P NEW EXIT LIGHT MOUNTED ON WALL SECURITY ROOM DETAIL ELM 0101 REVIEWED FOR DE COMPLIANCE NFPA 70 - NEC pcii 1 1 Luud C Tukwila riDim [mem ••••• EmmIl RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 0 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 Expires k 3 Lic , -.), ) ,C/31P:-. • C.c) - ■cj ) NA r4 NPIJ•i 4 WAW Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM DL ZJ Proj. Mgr.: KCM Date: 12-12-08 Revision 01-05-09 01-15-09 01-26-09 02-02-09 11.2 1 ?7,. 7 ;1 Sheet NO. E-9 01111•111.11.11.1yOmemagist 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET 111=1111111111111■1111111igglim Project No. WTA. 08093 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - NORTH () EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER -24 BATTERY • EX. 1 /2 "W UP AND 1 "VV DOWN TO BELOW RAISED FLOOR. 1 FUTURE UPS BATTERY CELLS 1 -240 ❑ i I PANEL PANEL I. "BPPB1" a T • "BPPA I 1~ 0 EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. SPDB #1 SPDB #1 MPDB R EC 1 R EC� 2 1. ❑ r RECT. 3 RECT, 4 RECT. 5 RECT. 6 RECT. 7 SCALE: 1/4" = 1' -0" J RECT. 9 RECT. RECT. 8 10 1 F7- / / /I CRAC #27 USB1 31,3,35 ❑ L (s) D p'elYER ROOM I 1 NOTES INDICATED BY NUMBER IN 0: 1. EXISTING LIGHT FIXTURE SHALL BE RELOCATED TO NEW LOCATION. CRAC #28 DSA1 25,27,29 j.___f 1 .. ------ FUTURE UPS 4B 500 KVA NEW UPS 2B 500 KVA 0.9 PF FUTURE UPS 3A • 500 KVA / / I f 31_0 .. ❑ ❑ RECT. RECT. 7 RECT. RECT. 10 8 0 z w w U 0 i SPDB #1 I� / / / / /I PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - POWER ROOM SPDB #1 ANALASER � 1-p PANEL ZONE 3 BOX GR PPA1 f 1 EXISTING3 TERM. PLANT #2 1 ROW 2 TIER -24 BATTERY EXISTING TERM. PLANT #2 STRIN #4 1 ROVV 2 TIER 24 BATTERY • FUTURE UPS BATTERY 3A CELLS 1 -240 C 3 PANE "CRPPBI" P ELoo 10 :_3 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC I 11 LuuJ City Tukwila - LD IVIS!ON RECEIVED CITY OF TUKWI! A FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 3 IONE 2 3 4 Expires W G�s4 c7� t :i.au !t Proj. Mgr.: KCM 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 r p o r- ND� r� r -MN I. w pl ■ W o 0 Z >J Z E N 0< !' I.1fo 42053 L'iON -Lt- ,,41 PI VIP 1 OCI (f) cr` CI D l L l tNi Sri Fac, Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ ommignamairsimplumimiMilifizANIUM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No, WTA. 08093 Sheet No. E -10 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - POWER ROOM L 1 () EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER -24 BATTERY • EX. 1 /2 "W UP AND 1 "VV DOWN TO BELOW RAISED FLOOR. 1 FUTURE UPS BATTERY CELLS 1 -240 ❑ i I PANEL PANEL I. "BPPB1" a T • "BPPA I 1~ 0 EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. SPDB #1 SPDB #1 MPDB R EC 1 R EC� 2 1. ❑ r RECT. 3 RECT, 4 RECT. 5 RECT. 6 RECT. 7 SCALE: 1/4" = 1' -0" J RECT. 9 RECT. RECT. 8 10 1 F7- / / /I CRAC #27 USB1 31,3,35 ❑ L (s) D p'elYER ROOM I 1 NOTES INDICATED BY NUMBER IN 0: 1. EXISTING LIGHT FIXTURE SHALL BE RELOCATED TO NEW LOCATION. CRAC #28 DSA1 25,27,29 j.___f 1 .. ------ FUTURE UPS 4B 500 KVA NEW UPS 2B 500 KVA 0.9 PF FUTURE UPS 3A • 500 KVA / / I f 31_0 .. ❑ ❑ RECT. RECT. 7 RECT. RECT. 10 8 0 z w w U 0 i SPDB #1 I� / / / / /I PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - POWER ROOM SPDB #1 ANALASER � 1-p PANEL ZONE 3 BOX GR PPA1 f 1 EXISTING3 TERM. PLANT #2 1 ROW 2 TIER -24 BATTERY EXISTING TERM. PLANT #2 STRIN #4 1 ROVV 2 TIER 24 BATTERY • FUTURE UPS BATTERY 3A CELLS 1 -240 C 3 PANE "CRPPBI" P ELoo 10 :_3 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC I 11 LuuJ City Tukwila - LD IVIS!ON RECEIVED CITY OF TUKWI! A FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 3 IONE 2 3 4 Expires W G�s4 c7� t :i.au !t Proj. Mgr.: KCM 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 r p o r- ND� r� r -MN I. w pl ■ W o 0 Z >J Z E N 0< !' I.1fo 42053 L'iON -Lt- ,,41 PI VIP 1 OCI (f) cr` CI D l L l tNi Sri Fac, Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ ommignamairsimplumimiMilifizANIUM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No, WTA. 08093 Sheet No. E -10 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - POWER ROOM L () EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER -24 BATTERY • EX. 1 /2 "W UP AND 1 "VV DOWN TO BELOW RAISED FLOOR. 1 FUTURE UPS BATTERY CELLS 1 -240 ❑ i I PANEL PANEL I. "BPPB1" a T • "BPPA I 1~ 0 EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONS/VERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. SPDB #1 SPDB #1 MPDB R EC 1 R EC� 2 1. ❑ r RECT. 3 RECT, 4 RECT. 5 RECT. 6 RECT. 7 SCALE: 1/4" = 1' -0" J RECT. 9 RECT. RECT. 8 10 1 F7- / / /I CRAC #27 USB1 31,3,35 ❑ L (s) D p'elYER ROOM I 1 NOTES INDICATED BY NUMBER IN 0: 1. EXISTING LIGHT FIXTURE SHALL BE RELOCATED TO NEW LOCATION. CRAC #28 DSA1 25,27,29 j.___f 1 .. ------ FUTURE UPS 4B 500 KVA NEW UPS 2B 500 KVA 0.9 PF FUTURE UPS 3A • 500 KVA / / I f 31_0 .. ❑ ❑ RECT. RECT. 7 RECT. RECT. 10 8 0 z w w U 0 i SPDB #1 I� / / / / /I PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - POWER ROOM SPDB #1 ANALASER � 1-p PANEL ZONE 3 BOX GR PPA1 f 1 EXISTING3 TERM. PLANT #2 1 ROW 2 TIER -24 BATTERY EXISTING TERM. PLANT #2 STRIN #4 1 ROVV 2 TIER 24 BATTERY • FUTURE UPS BATTERY 3A CELLS 1 -240 C 3 PANE "CRPPBI" P ELoo 10 :_3 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC I 11 LuuJ City Tukwila - LD IVIS!ON RECEIVED CITY OF TUKWI! A FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 3 IONE 2 3 4 Expires W G�s4 c7� t :i.au !t Proj. Mgr.: KCM 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 r p o r- ND� r� r -MN I. w pl ■ W o 0 Z >J Z E N 0< !' I.1fo 42053 L'iON -Lt- ,,41 PI VIP 1 OCI (f) cr` CI D l L l tNi Sri Fac, Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ ommignamairsimplumimiMilifizANIUM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No, WTA. 08093 Sheet No. E -10 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - POWER ROOM BUS A- Isc46224 A w m CL 0 0 m 31,596A, 16G= 1,900A. I sc., = 1,853A, 0 0 tp CO 0 w SPARE UPS 1 11 300 KVA Inc = 34,669A.- BATTERY s rri LL r C 0 D SHORT CIRCUIT CURRENT IS 34,669A. REMOVE EXISTING PDU 1 -2 AND ASSOCIATED FEEDER BREAKER AND CIRCUIT. EXISTING PANELBOARD UPP1 (480V., 30, 3W, 65KAIC) 1 2 LL r 0 101 f) 111 s( 50KVA 50KVA PDU 1 -1 PDU 1 -2 SWITCH SWITCH ROOM ROOM H LL_ / 0 0 0 L o co o c(r) I6v 31,59 C7 L SPARE SS Q3BP MAINT. BYPASS U w 0 < u- • � O 0 0 m PDU E 166.01 L = •4,364A. FUTURE UPS 4B BY -PASS SPARE -k FUT. 8,418A. XFMR "UTRR1 -l" " ( ; 45KVA 7,9964. ± f- - - -1_. .._.1 FUT. 1 PNL 'URDP1 -1'h ELECTRICAL ROOM rr 102 EXISTING PNL URDP1 -2" [TVSS EXIST. DIST. PNL "BPPA1" REMOVE THREE EXISTING (100A,150A,125A) GE SELA SERIES SPARE CIRCUIT BREAKERS OR AT CONTRACTOR'S OPTION, THE CONTRACTOR MAY USE SPACE ABOVE MAIN BREAKER AND INSTALLA NEW 250AT /250AF. 480V., 3-P, 65 KAIC CIRCUIT BREAKER TO SERVE NEW PDU 166.01 6 7 H u- C2 Q / 8( Ug -4( � U Q ( lci r t r-- t o r-- p EX. XFMR EX. XFMR "UTRR1 -2" "UTRR1 -3" -•- -- 45KVA L EXISTING PNL URDP1 -3' EXIST. DIST. PNL "BPPA2" OFFICE ELECTRICAL AREA ROOM FA, HSSD FA, HSSD, WORKSTATION REEL 9 10 LL- g (V Ln . h u) 4 FUTURE UPS 5A PRIMARY INPUT T L EXIS TING PNL "ULPPI -I" UPS LIGHTING L 0 0 0 Lo / JJ BUS I 38,366A. I6 - 11.947A. EX. XFMR "UTRL1 -1 45KVA REMOVE EXISTING 600AT /600AF BREAKER AND INSTALL NEW 800AF /800AT 480V., 3 -P CIRCUIT BREAKER 100% U.L. RATED G.E. SKLL36AT0800, 65 KAIC WITH SRPK 800A 800 TRIP MODULE. A Ifi,: n, 765A. SPARE SPARE 103 B C 0 0 1 00' co CO ( Sa t coo (X) EXIST. PNL "DSAI" m (J) a :a z 4 0 O co O T rVSS EXIS r. DIST. PNL "CRPFAI" 30A, 3-P, 48C V., NO -FUSE NE\AA 1 ----- A U. 1 -LL. U, 1-u-0 1 0 O` ) 0 0 0 (0 (0 to V (0 EXIST. MCC N W CHILLED VV R PUMP O. 3 -08 B SPARE SCALE: NONE 104 \CD\ EX. CHILLER -1 178 TON u_ Y 0 0 1 Lo r (0 r t, 06= = 17, 797A. : =/ 166 =17,364A. 4000AT � [Ed 4000AF 65KAIC D E NEW CHILLER NO. 3-08 178 TON FUTURE UPS 3A PRIMARY INPUT L EX. DIESEL GENERATOR 277/480V, 30, 4W 2000KW, 2500KVA G1 T 105 0 0 AS P T CONTROLS1 3000AT 1 3200AF / 24VDC ST Al _ I NO TED LivSS OFCI OUTDOOR METERING— r UTILITY REVENUE METER (f �J 106 L MAIN DISTRIBUTION SWITCHBOARD 4000A, 480V, 30, 4W, + GND., G5KA IER T _ Is,; = 46,269A. AS1 4000AT 4000AF 65KAIC\ n I. = 47,999A. - -d ENTRANCE in,:= 4,441A. N1 NC UTILITY TRANSFORMER 2500KVA, OIL - FILLED 26KVA: 480Y/277, 30, 4W-- 1 Y 1 Y - YM 1UTX-A L 107 108 _AUTOMATIC THROWOVER SWITCH TIE 4000AT r 4000AF 65KAIC INO T . INTERLOCK UPS IN BYPASS PLC -A f -- �l PLC - 9 9. r REMOVABLE LINK EX. 30 .F NEUTRAL. LANDING FUTURE UTILITY REVENUE METER L_ TRANSITION DUCT 4000A, 30, 4W r 1 CL UTILITY CABLES EX. (2) 4 "C. EACH MV ELECTRICAL ONE LINE DIAGRAM r UTX -B L_ NC n FUT. DIESEL GENERATOR 277/480V, 30, 4W 2000KW, 2500KVA \ -• , CONTROLS 3000AT 3200AF 24VDC ST N2 [Ed 4000AT 4000AF 65KAIC CO - r 109 TO EX. UTILITY XFMRS 1 480V TO EX. BLDGS 2&3 GROUND TO RAISED FLOOR GROUND SYSTEM. REFER TO GROUNDING PLAN, TYPICAL NO FUTURE OFCI OUTDOOR METERING FUTURE UTILITY TRANSFORMER 2500KVA, OIL- FILLED 26KVA: 480Y/277, 30, 4W EX. CL EX. MV LOOP SWITCH 26 KV, 30 7. MV EX. (2) 4 "C. EACH < 0 4 Z N N co A2 I EQ] 1 4000AT 4000AF / r CA J VAULT I I — I L J EXISTING VAULT P P N N L L 1 2 PDU 143.02 REPLACE EXISTING STANDARD 1200A CIRCUIT BREAKER WITH A NEW 1000AF /1000AT 480V., 3 -P, 100% U.L. RATED G.E. SKLL36AT1000, 65 KAIC WITH SRPK 1200A 1000 TRIP MODULE EXIST, MCC a <4 N N (0 J PDU 145.02 EX. MV LOOP V - Z 26 KV, 30 EX. 2 -4" CO FOR SERVICE TO EX. BLDG 1 CITY LIGHT SWITCH PAN MOUNTED 7'x1" PAD y P P P N N N N L L L L 1 2 3 4 110 C u 0Q SPARE 1 SPARE \O\ EX. C HILLER -2 178 TON 480V. DC BATTERY — REFER TO DC DWGS --T 400 co N Lo (o 00 r r E I— D m Z Z a 4 2 za 5( I 4 1 P P N N L L 2 3 PDU 164.01 LL U 0 0 1 - SS MAINT. BYPASS wC 3- P N L 4 A SPARE SPARE NEW 11 UPS 26 500 KVA 0.9 PF Q3BP 16 = 32,878A. 4 U E Y N N ( ) I rs. = 13,924A. B MAI NT. BY -PASS MBP 4 -1 =14 P N N L L 1 2 PDU 145,16 EXIST. PNL "DSB1" MAIN DISTRIBUTION SWITCHBOARD BUS -B F- U 0 Lo SPARE 44 N N k 7,209A. 10 6,64 10 E [TVSS ] EXIST. DIST. PNL "CRPPBI" BUS I.= 32,878A 6 SPARE SPACE BUS B w 0 0)4" <$c:" � 4" " o8 � ° / ° i W U) (.0 (0t)(D (n r FUTURE UPS 3A BY -PASS SPARE 112 TVSS1 EXIST. DIST. PNL "BPPB1" NEW DIST. PNL BD DP2B" 800A, 480V., 30, 3W, 65KAIC C IL U C w D Lo L 1 EXIST. DIST. PNL "BPPB2 Is 46224 E 11. ALL UPS BREAKERS ARE 65 KAIC RATED. T FUTURE UPS 46 PRIMARY INPUT NOTES INDICATED BY NUMBER IN 0: w U 5. SHORT CIRCUIT 3 PHASE CURRENT TO PANEL DSB1 IS 38,366A. 6. SHORT CIRCUIT 3 PHASE CURRENT TO PANELS BPPA1, BPPA2, BPPBI, AND BPPB2 ARE 35,169A. 7. SHORT CIRCUIT 3 PHASE CURRENT TO EXISTING UPS PRIMARY AND BYPASS CIRCUIT IS 40,509A. 9. SHORT CIRCUIT CURRENT CALCULATED ONLY WHEN GENERATOR IS IN SERVICE. (1) 4: < < 0 0 ) 0 0 L o w(0q (0(0(o CD D FUTURE UPS 5A BY -PASS 1. SHORT CIRCUIT 3 PHASE CURRENT FOR CHILLER CIRCUIT IS 23,386A. 2. SHORT CIRCUIT 3 PHASE CURRENT FOR MOTOR CONTROL CENTERS ARE 16,780 A. 3. SHORT CIRCUIT 3 PHASE CURRENT TO PANELS CRPPA1 AND CRPPB1 IS 36,693A. 4. SHORT CIRCUIT 3 PHASE CURRENT TO PANEL DSA1 IS 35,169A. 8. SHORT CIRCUIT 3 PHASE CURRENT TO NEW UPS PRIMARY AND BYPASS CIRCUITS IS 36,518A. 10. TYPICAL SHORT CIRCUIT CURRENT FOR EACH NEW PDU ON DISTRIBUTION PANELBOARD "DP2B ". LOOtO B 113 1— U 00y CO (,0 SPARE SPARE REVIEW: D FOR CODE COM PLIANCE NFPA 7 $ - NEC 1 11 'tuuJ BUILDING kwlla IVISIO& w 0 (r) a w (n RECEIVED CITY OF TUKWILA FEB 0 5 7nnq PERMIT CENTER 2 3 4 iwn 3 WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS IoO E3 for w... o► 5h� � N %OW W o CI M Wo Z' r welt >Jo W � z 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 j 2� () co 0 m �° o Q � Z ¢� L11 c K LLI N J co (0 cf) (/) N (f) VP" Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision Sheet No. E -1 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 ELECTRICAL ONE LINE DIAGRAM POWER WIRING TABLE RUN NO. FROM TO WIRE RATING QTY OF WIRES NOTES 1 -1 MAIN SWITCHBOARD MDSB -11 OE POWER MODULE UPS 2B INPUT 1000A 3 -400 MCM'S 1 - #2/0 GND., IN EA OF (3) 3" C. BATTERY HIGH TEMP. 2 - 1 MAIN SWITCHBOARD MDSA -103D MAINT BYPASS CAB POWER MODULE UPS 2B 800A 3 -600 MCM'S 1 - #1/0 GND., IN EA OF (2) 3-1/2" C. FAULT BATTERY CHARGING 3 -1 UPS 2B OUTPUT PANELBOARD DP2B 800A 3- 600MCM'S, 1-#1 /OGND., IN EACH OF (2) 3-1/2" C. RECTIFIER VOLTAGE FAULT 4 -1 UPS OUTPUT "DP2B" TYPICAL PDU 250A 3 -250 MOM'S 1 -#4 GND., IN 2 -1 /7 C. TYPICAL PDU FEEDER 5 -1 MAIN SWITCHBOARD MDSA -104D NEW AIR COOLED CHILLER #3-.08 450A 3- #410'S, 1 - #2 GND., IN EA OF (2) 2 "' C NEW CKT IN EXISTING UNDERGROUND CONDUITS 6 -1 MOTOR CONTROL CENTER "MCCA" NEW CHILLED WTR PUMP #3 -08 30A - 3#10 "S, 1 - #10 GND., IN 3/4 "" C. NEW CKT IN EXISTING CONDUITS 21 CONTROL WIRING TABLE RUN NO. FROM TO DESCRIPTION NOTES 16 -1 BATTERY 1 UPS 2B 2 -PAIR 16AWG IN 3/4" , CONDUIT UPS 26 BATTERY PLANT ALARM /CONTROL WIRING DISCONNECT IBEZ-XR3-7,8,11,12 TB -1 18 - 1 UPS 2B MAINT. BYPASS 1 -PAIR 16AWG INTERNAL WIRES FUNISHED WITH UPS. INSTALLED BY CONTRACTOR CABINET UPS 2B IBEZ -XR2 -4 IBEZ -XR2 -5 TB2 -10 TB2 -11 22-1 ALL UPL1Fl COM. BAS INTERFACE 2 -PAIR 22AWG SHEILDED BAS INTERFACE BY BAS CONTRACTOR PORT DIGITAL DATA POINTS INDEX (Al) POINTS 1 BATTERY CKT. BREAKER 2 BATTERY DISCHARGING 3 LOW BATTERY VOLTAGE 4 LOW BATTERY WARNING 5 BATTERY HIGH TEMP. 6 ALARM MAINS 1 VOLTAGE 7 FAULT BATTERY VENT 8 FAULT BATTERY CHARGING 9 RECTIFIER STATUS 10 RECTIFIER FAULT 11 RECTIFIER VOLTAGE FAULT 12 RECTIFIER FREQUENCY FAULT 13 SYSTEM NORMAL 14 SYSTEM DOWN GRADED 15 INVERTER CONNECTED 16 INVERTER FAIL 17 STATIC SWITCH STATUS 18 UPS ON BATTERY - FORCING 19 BATTERY CHG. OFF - FORCING 20 INVERTER OUTPUT SWITCH 21 UPS ON BYPASS 22 UPS ON MAINT. BYPASS BATTERY BACKUP TIME ANALOG DATA POINTS INDEX (Al) POINTS 1 KW PHASE A,B,C 2 KW TOTAL 3 KVA PHASE A,B,C 4 KVA TOTAL 5 To PEAK PHASE A,B,C 6 % TOTAL LOAD 7 % INVERTER LOAD 8 POWER FACTOR 9 MAINS 1 CURRENT PHASE A,B,C 10 MAINS 1 VOLTAGE PHASE A -B, B-C, C -A 11 MAINS 1 FREQUENCY 12 MAINS 2 CURRENT PHASE A,B,C 13 MAINS 2 VOLTAGE PHASE A -B, B-C, C -A 14 MAINS 2 FREQUENCY 15 INVERTER CURRENT PHASE A,B,C 16 INVERTER VOLTAGE PHASEA -B, B-C, C -A 17 18 INVERTER FREQUENCY LOAD CURRENT PHASE A,B,C 19 LOAD VOLTAGE PHASE A -B, B-C, C -A 20 LOAD FREQUENCY 21 BATTERY CURRENT 22 BATTERY VOLTAGE 23 BATTERY BACKUP TIME 800/3 MDSA -103D 1000/3 MDSB - 110E UPS SYSTEM INTERFACE PANEL Q4S 1000AF 800AT NO SCALE UPS 2B 500KVA/450KW INPUT: 480VAC., 60Hz, 3PH, 3W OUTPUT: 480VAC., 60Hz, 3PH, 3W Q1 f C 1000AF l 1000AT 11 Q4S 1000AF 800AT INPUT FILTER II 1 H 0 0 RS-232 TO RS-485 CONVERTER NO SCALE R � TX+ 1%. RCVF BATT. DISCONNECT REFER TO DC DWGS -- BATT 28 REFER TO DC DWGS TB s*> X X UPS WIRING DIAGRAM - UPS 2B frA /// Z 120VAC TX-n RC- Q 0 4 18 -1 164 MGE UPS DATA POINTS w STATI 1 SWITCICI STATIC SWITC NEW UPS COMM. LOOP, RS -485 CABLE - 2 PAIR 2 GA. SHIELDED IN 3/4" CONCUIT. 0 0 Q3BP 1000AF 800A Q5N 1000AF 800A TB2 ADDR =1 ADDR =2 CO NEW UPS TO NEW COMM. LOOP. RE= _ R TO TYPICAL UPS SERIAL INTrRFAC DETAIL 5, THIS SHEET. UPS INTEGRATION DIAGRAM - MGE 7000 SERIFS MAINT. BYPASS CABINET 2B DB25 MALE PIN NO.1 2 3 4 5 6 6 7 8 9 B &B ELECTRONICS RS232/RS485 CONVERTER 485019TB WITH EXTERNAL POWER SUPPLY 485PS2 (NO ECHO & RTS CTRL) NO SCALE TO PANELBOARD DP2B RS-485 CONVERTER UV BATT. DISCONNECT ENCLOSURE RS485 TRUNK TD(A) RD(B) TD(B) RD(B) GND +12VD C NO SCALE TB1 1 2 3 4 PIN 5 (R +) PIN 4 (T +) PIN 3 (R -) PIN 2 (T -) PIN 1 (GRD) NEW COMM. LOOP MGE UPS COMM. TERMINAL RAUZ -XR11 UPS SERIAL INTERFACE TO NEXT UPS 7 8 11 12 XR3 IBEZ PCA UPS MODULE JUMPERS FURNISHED FROM FACTORY BETWEEN BY -PASS AND PRIMARY INPUT TERMINALS - DO NOT INSTALL BATTERY DISCONNECT CONTROL /ALARM WIRING DIAGRAM TYP. FOR EACH UPS TB2 TB1 MBP CABINET CKT. FROM BYPASS SOURCE D 4 2 4 3 2 C6 B6 A6 l f /ff/',f 2 -j UPS CKT.�S FROM PRIMARY FEED SOURCE 11111111 MI B3 C3 UPS INPUT UPS MODULE w TO Q1 INPUT BRKR 480V. DC CKT FROM BATTERY DISCONNECT. REFER TO DC DWGS ta 2 1 3 C6 86 A6 XMQ3BP XMQSN BY -PASS INPUT TO Q4S BY -PASS BRKR. UPS OUTPUT FROM UPS CONNECTING DIAGRAM SCALE: NONE NOTES: 1. POWER WIRING BUSES ARE DESIGNED FOR TWO HOLE BARREL LUGS. 2. ELECTRICAL JOINT COMPOUND ALCOA TYPE "2EJC" OR EQUIVALENT SHOULD BE APPLIED TO THE BUSBARS PRIOR TO CONNECTING THE TWO HOLE BARREL LUGS. 3. GRADE 5 HARDWARE IS RECOMMENDED WITH TORQUE REQUIREMENTS AS FOLLOWS: BOLT DIAMETER TORQUE (INCH POUNDS) 3/8" 372 1/2" 900 9/16" 1200 6 5 XR9 XR2 MAINTENANCE BY —PASS thc+ 4. CONTROL WIRING MUST BE ROUTED IN INDIVIDUAL SEPARATE CONDUITS FROM POWER WIRINGS. EVERY RUN NUMBER INDICATES INDIVIDUAL SEPARATE CONDUITS. 5. CONNECT GROUND FRAMES OF ALL EQUIPMENT ACCORDING TO NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES. OBEZ IBEZ CIRCUITS BY CONTRACTOR CABLING SUPPLIED BY MGE CONNECTED BY CONTRACTOR REVIEWED FOR CODE C OMPLIANCE A 70 - NEC FLU 11 2uud rOfTukwlla O— !�IVIsION RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT ©2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 3 I D vD - 012 U r� W�u1 z -01N — A AOW W0 � Wo !I (13 O Expires 9� co c o icc c J co k (0 Fac. Code TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM DL ZJ Proj. Mgr.: KCM 2 3 4 Date: 12 -12 -08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 Sheet No. E-12 100% CD 95% REVIEW ADD. NO. 1 PERMIT SET Project No. WTA. 08093 UPS WIRING DIAGRAM AND FEEDERS TABLE MAIN BREAKER/INCOMING LUGS CHILLED WATER PUMP 1 NEW. CHILLED WATER PUMP 3 SURGE ARRESTER (TVSS) MAIN BREAKER/INCOMING LUGS CHILLED WATER PUMP 2 FAN COIL UNIT FCU-1 DUCT HEATER SPARE HUMIDIFIER SERVES MAKE-UP AIR UNIT MAU-1 DUCT HEATER SERVES SURGE ARRESTER (TVSS) NOTES: 1. REPLACE EXISTING 100AF/80AT, 3-P 480V. CIRCUIT BREAKER(GE SELA36AT0100) CRAC UNITS. NEW CRAC UNITS ARE NOT EQUIPPED WITH ELECTRIC REHEAT OR DEVICE NO. DEVICE NO. 1 2 3 4 5 6 7 2 3 4 EXISTING MOTOR CONTROL CENT 5 6 DEVICE NO. DEVICE VOLTAGE RATING 480 480 480 480 480 DEVICE VOLTAGE RATING 480 480 480 480 480 480 480 480 MAG-GARD CIRCUIT BREAKER NO. POLES 3 3 3 3 3 3 3 SERVES 3 3 3 3 3 3 EXISTING MOTOR CONTROL CENTE SERVICE: 480V., 30, 3W MAG-GARD CIRCUIT BREAKER NO. POLES MINIMUM INTERRUPTING CAPACITY: 65,000A. PDU 143.02 PDU 145.02 PDU 164.01 PDU 145.16 SPARE SPACE ONLY INT. CAP. SYM. AMPS. 65,000 65,000 65,000 65,000 65,000 65,000 INT. CAP. SYM. AMPS. 65,000 65,000 65,000 65,000 65,000 65,000 65,000 BREAKER FRAME AMP 250 250 250 STARTER SIZE 2 1 2 2 2 1 40A/3P 30A/3P STARTER SIZE 30A/3P 30A/3P 60A/3P PANELBOARD "DP2IEr SpHDULE TRIP AMP sTAR 1-5TOP PUSH-BUTTON MAINTAINING CONTACT START-STOP PUSH-BUTTON MAINTAINING CONTACT 250 145 250 145 580 R ' MAGNE HAND-OFF AU 0 YES MA 'NET! CONTACTOR HAN -OFF AUT LOAD AMP/L 2 145 145 580 RIP M pDULE WITH NEW 30A TRIP MODULE TO SERVE NEW HUMIDIFIER. 145 3 145 580 MCCA" SCHEDULE C CONTACTOR RED-PILOT LIGHT YES CCB" SCHEDULE RED-PILOT LIGHT 3 #.250 MCM'S, 1 #4 GND., IN 2 MOTOR HP 15 15 2 MOTOR HP 15 2 15 0.0 0.0 AMPS 3,4 30.1 21.1 21.1 3.4 30.1 0.0 AMPS 211 2'1.1 MAIN LUG RATING 800A. TYPE MOUNTING WALL CONDUCTOR & CONDUIT 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. REMARKS PROVIDE NEW STARTER/BREAKER FOR NEW PUMP IN EX. SPACE. REMARKS NOTE 1 NOTE 1 LOg 0 10 1 NOTE 1 NOTE 1 REVIEWED FOR O DECOMPLIANCE NFPA 70 - NEC I 1 1 kuud 11 RECEIVED CITY OF TUKINILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT ©2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 Ts MAN o v wA s 11 4 r , , - 0 1 10 , Lc IN )i)/ 1 1 1 1 ' 1; .70? Expires ( 7 . -0/1/) 1 1111•NM=1.111...mmumwmaimml I 0 la r• 0 0 in EN W I ? W n , 1- w Z < w -01 d wo L r-w-6 > Z wcl O2 Proj. Mgr.: KCM Revision _Affill1111•1111 01-15-09 01-26-09 02-02-09 Sheet No. Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Date: 12-.12-08 01 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 3 ELECTRICAL PANEL SCHEDULES EXISTING PANEL "CFRPPB1u SCHEDULE FED FROM 1VIDSB EXISTING PANEL "CRPP ly SCHEDULE FED FROM MDSA SERVICE: 277/480V., 30, 3W. CONDUCTOR COLOR M. L. 0. BUS RATING A. CODE LOAD MINIMUM CIRCUIT BREAKER LEG 1 - BROWN 588A. INTERRUPTING CAPACITY LEG 2 - YELLOW 588A. 65,000 A. LEG 3 - PURPLE SEPARATE GROUNDING BAR - OR MAIN BREAKER RATING 800A. 588A. GROUND - GREEN GROUNDED PANEL MAY BE TOP OR BOTTOM FEED AT NEUTRAL - GREY - MAIN BR EAKE CONTRACTORS OPTION MAIN LUGS Or AS INDI ATE, Y A. SYM. INTER. CAP. POLE NO. SERVES LOAD BREAKER - POLE NO. ' 2 3 _L POLE NO. POLE NO. ' ERVES LOAD BREAKER POLE NO. LEG AMPS 2 3 POLES LEG AMPS 1 2 ' POLES 3 POLES - 1 2 3 POLES 1 1 ___ 3 80 2 80 1 3 2 4 ,RAC 2 4 80 CRAC #6 80 r 2 3 CRAC #1 CRAC #8 80 80 7 i 3 5 80 5J 80 3 r 7 9 _ 11 - 6 80 1 7 1 80 7 1 7 80 80 80 8 80 1 80 80 80 8 10 12 9 F CRAC #5 10 80 8 10 4RAG 11 1 10 l_ 12 80 80 11 3 11 ' 12 13 80 80 1 80 80 13 80 V 13 14 80 80 80 80 15 l i CRAG #22 14 15 CRAC #13 80 15 15 16 II RAC 5 3 80 17 J 16 17 J 3 80 L 17 19 80 17 80 18_ 19 20 14 80 3 -18 19 1 21 80 80 80 19 21 L23 201 CRAC #23-08 14 14 3 ,7 22 1 L24 J 23 _, 14 25 30 20 CRAC #17 80 V 80 26 1 28 CRAC #25-08 21 14 14 30 26 1 28 ; 30 •RAC . 21 22 Z 6-08 ..- 14 22 3 L 29 , 30J 80 7 V 23 24Y - 23 80 V 31 14 3 L24 25 - - 80 r 25 32 33 (F) CRAG - - 3 33 35 --*-- 34 - 36. 261 - 14 - 34 30 26 27 SPARE - - 7 3 27 37 _ *RAC . 8-08 38 28 14 14 {28 29 31 i - 30 39 29 40 TVSS 30 40 80 V 31 33 .. 35 32 - - 4'1 _. 42 - r 32 33 SPARE 42 - 7 7 1 EXISTING PANEL LIPA1 SERVICE: 277/480V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. 0. BUS RATING 34 L DO NOT SE THIS SPACE GROUND - GREEN GROUNDED PANEL MAY BE TOP OR BOTTOM FEED AT NEUTRAL - GREY - MAIN BREAKER OR MAIN BREAKER RATING A. .. AS INDICATED - 34 35 J BREAKER POLE NO. 123 2 _._4 POLE 36Y LOAD BREAKER POLE NO. - - 36 37 LEG - 1 2 - 37 39 38' NO. _ 3 POLES 30 V' / 38 40 L42 39 F - 20/1 - DO NOT USE THIS SPACE 40 > T /SS - 41 1 3 AREA LIGHTING ZONE 2 - - L41 42_, 4 - 3 • 20/1 4 5 AREA LIGHTING ZONE 1 MAIN BREAKER/INCOMING LUGS CHILLED WATER PUMP 1 NEW. CHILLED WATER PUMP 3 SURGE ARRESTER (TVSS) MAIN BREAKER/INCOMING LUGS CHILLED WATER PUMP 2 FAN COIL UNIT FCU-1 DUCT HEATER SPARE HUMIDIFIER SERVES MAKE-UP AIR UNIT MAU-1 DUCT HEATER SERVES SURGE ARRESTER (TVSS) NOTES: 1. REPLACE EXISTING 100AF/80AT, 3-P 480V. CIRCUIT BREAKER(GE SELA36AT0100) CRAC UNITS. NEW CRAC UNITS ARE NOT EQUIPPED WITH ELECTRIC REHEAT OR DEVICE NO. DEVICE NO. 1 2 3 4 5 6 7 2 3 4 EXISTING MOTOR CONTROL CENT 5 6 DEVICE NO. DEVICE VOLTAGE RATING 480 480 480 480 480 DEVICE VOLTAGE RATING 480 480 480 480 480 480 480 480 MAG-GARD CIRCUIT BREAKER NO. POLES 3 3 3 3 3 3 3 SERVES 3 3 3 3 3 3 EXISTING MOTOR CONTROL CENTE SERVICE: 480V., 30, 3W MAG-GARD CIRCUIT BREAKER NO. POLES MINIMUM INTERRUPTING CAPACITY: 65,000A. PDU 143.02 PDU 145.02 PDU 164.01 PDU 145.16 SPARE SPACE ONLY INT. CAP. SYM. AMPS. 65,000 65,000 65,000 65,000 65,000 65,000 INT. CAP. SYM. AMPS. 65,000 65,000 65,000 65,000 65,000 65,000 65,000 BREAKER FRAME AMP 250 250 250 STARTER SIZE 2 1 2 2 2 1 40A/3P 30A/3P STARTER SIZE 30A/3P 30A/3P 60A/3P PANELBOARD "DP2IEr SpHDULE TRIP AMP sTAR 1-5TOP PUSH-BUTTON MAINTAINING CONTACT START-STOP PUSH-BUTTON MAINTAINING CONTACT 250 145 250 145 580 R ' MAGNE HAND-OFF AU 0 YES MA 'NET! CONTACTOR HAN -OFF AUT LOAD AMP/L 2 145 145 580 RIP M pDULE WITH NEW 30A TRIP MODULE TO SERVE NEW HUMIDIFIER. 145 3 145 580 MCCA" SCHEDULE C CONTACTOR RED-PILOT LIGHT YES CCB" SCHEDULE RED-PILOT LIGHT 3 #.250 MCM'S, 1 #4 GND., IN 2 MOTOR HP 15 15 2 MOTOR HP 15 2 15 0.0 0.0 AMPS 3,4 30.1 21.1 21.1 3.4 30.1 0.0 AMPS 211 2'1.1 MAIN LUG RATING 800A. TYPE MOUNTING WALL CONDUCTOR & CONDUIT 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. REMARKS PROVIDE NEW STARTER/BREAKER FOR NEW PUMP IN EX. SPACE. REMARKS NOTE 1 NOTE 1 LOg 0 10 1 NOTE 1 NOTE 1 REVIEWED FOR O DECOMPLIANCE NFPA 70 - NEC I 1 1 kuud 11 RECEIVED CITY OF TUKINILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT ©2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 Ts MAN o v wA s 11 4 r , , - 0 1 10 , Lc IN )i)/ 1 1 1 1 ' 1; .70? Expires ( 7 . -0/1/) 1 1111•NM=1.111...mmumwmaimml I 0 la r• 0 0 in EN W I ? W n , 1- w Z < w -01 d wo L r-w-6 > Z wcl O2 Proj. Mgr.: KCM Revision _Affill1111•1111 01-15-09 01-26-09 02-02-09 Sheet No. Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Date: 12-.12-08 01 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 3 ELECTRICAL PANEL SCHEDULES EXISTING PANEL "CFRPPB1u SCHEDULE FED FROM 1VIDSB SERVICE: 277/480V., 30, 3W. CONDUCTOR COLOR CODE LOAD M. L. 0. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BROWN 588A. INTERRUPTING CAPACITY LEG 2 - YELLOW 588A. SEPARATE GROUNDING 65,000 A. LEG 3 - PURPLE 588A. BAR - GROUND - GREEN GROUNDED PANEL MAY BE TOP OR BOTTOM FEED AT NEUTRAL - GREY - MAIN BREAKER OR MAIN BREAKER RATING 800A. CONTRACTORS OPTION MAIN LUGS ONLY A. SYM. INTER. CAP. AS INDICATED POLE NO. SERVES LOAD BREAKER POLE 1 2 3 - SERVES LOAD LEG BREAKER AMPS POLE NO. LEG AMPS 1 2 3 POLES NO. NO. 1 2 3 POLES 1 80 80 7 1 ___ 3 __ 2 80 80 V_ 2 4 3 j CRAC #6 80 4 L CRAC #8 80 5 80 6 80 6 7 1 80 80 7 80 80 . 8 9 CRAC #10 80 9 10 CRAC #20 80 : 1 10 l_ 12 11 J 80 3 11 12 J 80 13 1 80 80 V 13 14L 16 80 80 fH4 15 l i CRAG #22 80 15 L CRAC #24 80 80 3 16 18 17 J 80 3 80 L 17 19 18J 80 19 20 14 30 r 1 21 ,- CRAG #26 80 80 ,- V 3 21 L23 CRAC #23-08 14 14 3 22 24f 22 1 L24 J 23 _, 25 .. 80 V 25 26 1 28 CRAC #25-08 14 14 30 26 1 28 ; 30 27 (F) CRAC . Z 27 ..- 29 J - 3 L 29 , 30J 31 - 80 V 31 32 - - 32 33 (F) CRAG - - 3 33 35 --*-- 34 - 36. DO NOT USE THIS SPACE - - 34 35 37 _ .. 37 38 - 30 38 39 DO NOT USE THIS SPACE - .. 39 40 TVSS - 40 41 - - 4'1 42 - 73 42 NOTES: 1. REPLACE EXISTING 100AF/80AT, 3-P 480V. CIRCUIT BREAKER(GE SELA36AT0100) TRIP MODULE WITH NEW 30A TRIP MODULE CRAC UNITS. NEW CRAC UNITS ARE NOT EQUIPPED WITH ELECTRIC REHEAT OR HUMIDIFIER. TO SERVE _ NEW EXISTING PANEL LIPA1 SERVICE: 277/480V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. 0. BUS RATING 600A. MINIMUM CIRCUIT BREAKER LEG 1 - BROWN INTERRUPTING CAPACITY LEG 2 - YELLOW SEPARATE GROUNDING 65,000 A. LEG 3 - PURPLE BAR 35% GROUND - GREEN GROUNDED PANEL MAY BE TOP OR BOTTOM FEED AT NEUTRAL - GREY - MAIN BREAKER OR MAIN BREAKER RATING A. CONTRACTORS OPTION MAIN LUGS ONLY A. SYM. INTER. CAP. AS INDICATED POLE NO. SERVES LOAD BREAKER POLE NO. 123 2 _._4 POLE SERVES LOAD BREAKER POLE NO. LEG AMPS LEG AMPS 1 2 3 POLES NO. 2 3 POLES 1 AREA LIGHTING ZONE 2 - 20/1 1 2 LIGHTING CONTROL PANEL - 20/1 2 3 AREA LIGHTING ZONE 2 - 20/1 3 4 N.W. EQPT. ROOM LTS . 20/1 4 5 AREA LIGHTING ZONE 1 - 20/1 5 • 6 S.W. EQPT. ROOM LTS . 20/1 6 7 AREA LIGHTING ZONE 1 - 20/1 7 8 N.E. EQPT. ROOM LTS - 20/1 8 9 BATTERY ROOM - 20/1 9 10 S.E. EQPT. ROOM LTS - 20/1 10 '11 CORRIDOR OFFICES - 20/1 11 12 SPARE BREAKER .. 20/1 12 13 OFFICES, 1ST FLOOR _ 20/1 13 14 SPARE BREAKER - 20/1 14 15 17 UPPER LEVEL LIGHTING - 20/1 15 16 SPARE BREAKER - 20/1 16 18 UPPER LEVEL LIGHTING .. 20/1 17 18 SPARE BREAKER _ - 20/1 19 UPPER LEVEL LIGHTING - 20/1 19 20 SPARE BREAKER 20/1 20 21 UPPER LEVEL LIGHTING .. 20/1 21 22 SPARE BREAKER 20/1 22 23 UPPER LEVEL LIGHTING - 20/1 23 24 SPARE BREAKER .. 20/1 24 25 UPPER LEVEL LIGHTING - 20/1 25 26 SPARE BREAKER - 20/1 26 27 UPPER LEVEL LIGHTING - 20/1 27 28 SPARE BREAKER - - 20/1 20/1 28 30 29 MEZZANINE PFFICES - 20/1 29 30 SPARE BREAKER 31 MEZZANINE PFFICES - - - 20/1 31 32 SPARE BREAKER - 20/1 32 33 STAIRWAYS, W/ROOMS 20/1 20/1 33 35 34 OFFICE - 20/1 34 35 ZONE 2 LTS 36 OFFICE . 20/1 36 37 ZONE 2 LTS - 20/1 37 38 SURGE ARRESTER (TVSS) - 20/1 38 39 ZONE 1 LTS - - 20/1 39 40 - - - (OFCI) - 20/1 40 41 ZONE 1 LTS 20/1 41 42 - 20/1 42 MAIN BREAKER/INCOMING LUGS CHILLED WATER PUMP 1 NEW. CHILLED WATER PUMP 3 SURGE ARRESTER (TVSS) MAIN BREAKER/INCOMING LUGS CHILLED WATER PUMP 2 FAN COIL UNIT FCU-1 DUCT HEATER SPARE HUMIDIFIER SERVES MAKE-UP AIR UNIT MAU-1 DUCT HEATER SERVES SURGE ARRESTER (TVSS) NOTES: 1. REPLACE EXISTING 100AF/80AT, 3-P 480V. CIRCUIT BREAKER(GE SELA36AT0100) CRAC UNITS. NEW CRAC UNITS ARE NOT EQUIPPED WITH ELECTRIC REHEAT OR DEVICE NO. DEVICE NO. 1 2 3 4 5 6 7 2 3 4 EXISTING MOTOR CONTROL CENT 5 6 DEVICE NO. DEVICE VOLTAGE RATING 480 480 480 480 480 DEVICE VOLTAGE RATING 480 480 480 480 480 480 480 480 MAG-GARD CIRCUIT BREAKER NO. POLES 3 3 3 3 3 3 3 SERVES 3 3 3 3 3 3 EXISTING MOTOR CONTROL CENTE SERVICE: 480V., 30, 3W MAG-GARD CIRCUIT BREAKER NO. POLES MINIMUM INTERRUPTING CAPACITY: 65,000A. PDU 143.02 PDU 145.02 PDU 164.01 PDU 145.16 SPARE SPACE ONLY INT. CAP. SYM. AMPS. 65,000 65,000 65,000 65,000 65,000 65,000 INT. CAP. SYM. AMPS. 65,000 65,000 65,000 65,000 65,000 65,000 65,000 BREAKER FRAME AMP 250 250 250 STARTER SIZE 2 1 2 2 2 1 40A/3P 30A/3P STARTER SIZE 30A/3P 30A/3P 60A/3P PANELBOARD "DP2IEr SpHDULE TRIP AMP sTAR 1-5TOP PUSH-BUTTON MAINTAINING CONTACT START-STOP PUSH-BUTTON MAINTAINING CONTACT 250 145 250 145 580 R ' MAGNE HAND-OFF AU 0 YES MA 'NET! CONTACTOR HAN -OFF AUT LOAD AMP/L 2 145 145 580 RIP M pDULE WITH NEW 30A TRIP MODULE TO SERVE NEW HUMIDIFIER. 145 3 145 580 MCCA" SCHEDULE C CONTACTOR RED-PILOT LIGHT YES CCB" SCHEDULE RED-PILOT LIGHT 3 #.250 MCM'S, 1 #4 GND., IN 2 MOTOR HP 15 15 2 MOTOR HP 15 2 15 0.0 0.0 AMPS 3,4 30.1 21.1 21.1 3.4 30.1 0.0 AMPS 211 2'1.1 MAIN LUG RATING 800A. TYPE MOUNTING WALL CONDUCTOR & CONDUIT 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. 3- #.250 MCM'S, 1- #4 GND., IN 2-1/2"C. REMARKS PROVIDE NEW STARTER/BREAKER FOR NEW PUMP IN EX. SPACE. REMARKS NOTE 1 NOTE 1 LOg 0 10 1 NOTE 1 NOTE 1 REVIEWED FOR O DECOMPLIANCE NFPA 70 - NEC I 1 1 kuud 11 RECEIVED CITY OF TUKINILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT ©2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 Ts MAN o v wA s 11 4 r , , - 0 1 10 , Lc IN )i)/ 1 1 1 1 ' 1; .70? Expires ( 7 . -0/1/) 1 1111•NM=1.111...mmumwmaimml I 0 la r• 0 0 in EN W I ? W n , 1- w Z < w -01 d wo L r-w-6 > Z wcl O2 Proj. Mgr.: KCM Revision _Affill1111•1111 01-15-09 01-26-09 02-02-09 Sheet No. Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Date: 12-.12-08 01 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 3 ELECTRICAL PANEL SCHEDULES PDU 145.02 PANEL "145.02/3" SCHEDULE FED F SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATINr A. . MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING LEG 3 BLUE 10 KVA BAR 35% 2 . 10,000 A. - GROUND - GREEN GROUNDED PANEL MAY BE TOP OR MAIN BREAKER OR MAIN BREAKER RATING NEUTRAL - WHITE BOTTOM FEED AT CONTRACTORS OPTION MAIN LUGS ONLY AS INDICATED SERVES POLE 111111 NMI ENI EMI SERVES LOAD LEG BREAKER AMPS P OLES POLE NO 1 12 3 ■.■■ POLE LOAD BR EAK g1I POLE NO. 6 10 12 16 20 22 26 28 30 34 38 4o LEG AMP 2 POLE SERVES NO. 1 1 1 1 NO. , 1 2 W POLa • - ®po ,,rr� - KIEL- pa ® -, IN - •J•IrL- - - 0 y si - �w � 3 �rl - ma IE 143.08 - L630 �ma III 3 a / 1 - L630 3 - POLES --- 144.12 - L630 MEM 3 11111131PMEI 142.12 - L630 - 30 _ MEE 143.09 - L630 - - 3o .4r 2 7 9 LMI111 13 151111@) 1111 1111 1111 mum 6 8 10 @J 144.02 - L630 J -E11 - 1 144.13 - L630 •EPJ 143.10 - L630 - -ma- - --- - mama NM 30 30 / 144.03 - L630 144.04 - L630 mama 0 - ® -- am 143.11 - L630 30 _ I EINI �J 111= 143.12 - L630 maL - - 30 _AIN 9 I1II 18 144.05 - L630 - ® Eli IMMIE Or- 144.14 - L630 - ma ® -LPL- 30 ./ 1111 1111 1111ESNMIII M ®MI ®- - ® � r- - 30 Pal - MIIFL>1- - 30 143.13 - L630 -mama - - ®- - - ma - 30 / ►EtElIIII 30 /r MillEMIIIIIIER 3 ° /I 21 -1111 IIII 1111 22 ZP1 26 3° 144.06 - L630 144.07 - L630 23 2 30 143.14 - L630 2 MIIIIIIIIIII - - - maMEE - 30 - %IEL- 30 .dl/ - %IEL- 3o J magi whi J 143.15 - L630 �ma 144.08 - L630 - 111111 30 /11111 ma rL -1111 E - - 1 142.06 - L630 ,MMI 31 1111 32 1111111MIEEEMIll 144.09 - L630 - W1 �J E1 IERI 41ma- 143.16 - L630 - 30 /r- 111 34 mama ®- - -- EN - 1111 mama - r L -1111 36 -Ma 143.17 - L630 - -- 30 /f- �ma- 39 1111Ei1 144.11 - L630 -ma- -ma ma - - 1111 40 MEM 30 .,M/r1m11111 MEM �� 20/1 41 111m= SPACE ONLY mil - 20 all 42 PDU 145.02 PANEL "145.02/4" SCHEDULE FED FROM UPS 2B DP2B SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING LEG 3 BLUE 10 KVA BAR 35% 10,000 A. - GROUND - GREEN GROUNDED PANEL MAY BE TOP OR NEUTRAL WHITE - MAIN BREAKER OR MAIN BREAKER RATING 225A. - BOTTOM FEED AT CONTRACTORS OPTION MAIN LUGS ONLY AS INDICATED POLE NO. SERVES LOAD BREAKER POLE NO. r1�11 12 3 POLE NO. LOAD BREAKER POLE NO. 4 LEG AMPS 123' ■ MA POLE SERVES NO. LEG AMPS 0 2 KIN POLES AMP III ME 3 POLES © mama 3 - POLES 1 144.12 - L630 MI 144.12 - L630 3 0 142.12 - L630 - 30 _ MEE - - - - - �L- 2 IIIIIK 30 -id/r J -E11 .I �r 9 1 144.13 - L630 - ® - 30 /11011111 - 111111111 6 Will 0 d il 6 142.13 - L630 ® -- 144.13 - L630 7 30 6 1 - maL J -1111 -mama 9 8 X11 M- 3 9 IMMIE 8 144.14 - L630 - ma ® -LPL- 30 ./ 9 1111 1111ESNMIII M 10 142.14 - L630 1! - 111111111MMELE11 - 30 / 30 _IrSIM 10 16 - mama 3° /[ gm 144.15 - L630 - -MI 2 30 r : IIIIECBJ MIIIIIIIIIII - _ 142.15 - L630 -- E - - EIIMEEND11111 - 111111 30 /11111 ma rL -1111 2 0 1 142.06 - L630 -- 0 16 - -1r MI - IIME 19 M1 IIERIMMIMIIIIIIMMIMIE 25 144.16 - L630 -- 30 �/f -1111 - 30 /r- 11111 ®- 1111 - k0 - MOM 142.16 - L630 IIM -Ma Ema - -� 30 18 144.17 - L630 144.1 8 - L630 -ma- -ma ma - - - MEM 30 .,M/r1m11111 MEM 19 23 1111 1111 - 2 ° 24 20/1 - 11111 28 PAM 20 142.17 - L630 MN - ma - 30 _ �L- fir- 22 28 1111111 - ® MUM (0 ter - 30 / 25 111 -ma ®L -1111 26 142,18 - L630 -IIII I Kw 31 WE -"; 143.14 - L630 - - - 34 1 -1111 i - - - 30 2 8 34 145.05 - L630 - - 30 /r -1111 - IMIE1 mama 30 / 35 1111 37 1111 3 ° 143.05 - L630 fir- - - -- mama --mg 30 , 3 ° IrlIEN 30 L- 36 145.06 - L630 - ® ma- „- MOM 30 .,./rE11111 31 I111@J 34 Nii 143.06 - L630 143.16 - L630 -�11 SPACE ONLY - L- 11111) 20/ 34 -11 145,07 - L630- mg - - 30 Ifw1111 34 I 37 38 143.07 - L630 mama - - 30 / 38 39 I 144.11 - L630 - - I 2 39 1 36 38 40 EN 40 1111 40 - -- - - 11111 J ma9�TN7�1�• SPARE SPARE SPARE 40 41 SPACE ONLY �- 20/1 41 20/1 42 SPACE ONLY mum im- 20/1 M ®- 20/1 PDU 143.02 PANEL "143 02/4" SCHEDULE FED FROMUP ;BDP2B MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING LEG 3 BLUE 10 KVA BAR 35% SERVICE: 120/208V., 30.4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATIN A. . MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUN 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% u ING ING 22 GROUND - GREEN GROUNDED PANEL MAY BE TOP OR NEUTRAL WHITE MAIN BREAKER OR MAIN BREAKER RA - BOTTOM FEED AT CONTRACTORS OPTION MAIN LUGS ONLY AS INDICATED POLE NO. 1 3 12 3 POLE NO. SERVES D 11:1 :54.4;11 POLE NO. 1 2 3 ..An II" POLE NO. SERVES LOAD [ REAK =3 POLES POLE NO . _! AMPS ©m. AMP III ME 3 POLES 1 2 30 / I POLE' 11/1 MI MI 144.12 - L630 ° mama 30 /r-I 2 142.02 - L630 - - - 0 JI 2 - 30 -id/r �- - IIIIIMENIE1111111 - 30 ....4101111111111 6 144.02 - L630 4 6 142.03 - L630 - - 111111111 6 Will 0 d il 3 6 ma - 144.13 - L630 7 IIIMMI - mar &WE 7 IIIIIK J 20/1 -mama 9 143.10 - L630 X11 - 3 9 144.14 - L630 ®MN ®ma ma 30 _Al - Minn 9 11 1111 IIII1113J 10 142.04 - L630 - 0-- M - - 0 .a KIEL- 0 Jars= 1! 10 2 6 1 amm @J IIIMI1 Ertl NM ME - 1 144.15 - L630 - mama 3° /[ IIII -ma. 142.05 - L630 2 MEENIIIIESEEILEINIII MI 16 MIIIIIIIIIII - - - E 144.16 - L630 _ - 111111 30 /11111 ma rL -1111 2 0 1 142.06 - L630 -- 0 - - -1r 0 Jar- - 144,17 - L630 M- -- 30 �/f -1111 22 142.07 - L630 11111 ®- " -�E - k0 - , MIIL- .,. 11 22 26 144.18 - L630 I Ema - -� - I.1111J 20 26 ) - mama 3 ° . /r 11 -I 2 L -1111 142.08 - L630 30 /r- 20 26 30 - - 20/1 WEE 12 28 • 145.05 - L630 �- 144.06 - L630 30 , -1111 30 142.09 - L630 - - (0 ter - 30 VII E -ma ®L -1111 ma M - ) 30 - 30 / r- 143.14 - L630 27 IIL- j� 34 immi 145.06 - L630 EZIKIIIIIIIIIIIIIIIME1111.1 i.1 145.07 - L630 110,1111111MIIIMIII Mill SPACE ONLY i - - - 30 r -1111 34 142.10 - L630 20/1 - MN ° „ - IMIE1 mama 30 / 35 1111 37 1111 36 38 142.11 - L630 - - - NE -_I - ° .e MEE Ir 36 40 143.07 - L630 - 11111M=ILEIMI 40 MIIIIME1111.1.1 MEE Nii -mok 20/1 41 143.16 - L630 42 SPACE ONLY - 3° - 20/ 34 42 PDU 143.02 PANEL "143.02/3" SCHEDULE FED FROM UPS 2B DP2B SERVICE: 120/208V., 30 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING LEG 3 BLUE 10 KVA BAR 35% 10,000 A. - GROUND - GREEN PANEL MAY BE TOP OR GROUNDED MAIN BREAKER OR MAIN BREAKER RATING 225 A. NEUTRAL -WHITE BOTTOM FEED AT CONTRACTORS OPTION MAIN LUGS ONLY AS INDICATED POLE NO. SERVES LOAD LEG BREAKER AMPS POLE NO. 1 3 12 3 POLE LOAD BREAKER POLE O LEG AMPS ■IIII�■ SERVES NO. 1 2 3 POLES I�� MIME' 1111113M 1 ©m. POLES j - L630 �__ 2 30 / I 143.18 - L630 11/1 MI MI 3 2 IMM Mall IJI 3 POLES - - - 143.09 - L630 � I - 30 -id/r -1111 NUMEI 6 144.02 - L630 - - 30 / 6 2 3 r ma - ISI L 1111QJ 3 142.13 - L630 142.14 - L630 - 4 =MEE 20/1 8 9 143.10 - L630 -ma M-® - - - 30 / I 2 9 11 1111 IIIINJ 10 144.03 - L630 i- - - - - 30 - 30 fir 10 - IIIM �1 143.11 - L630 30 /fi 20/1 - 1 144.04 - L630 142.05 - L520 I - -ma. 20/1 2 15 MI 16 MIIIIIIIIIII 142.06 - L630 - ma E 16 11Mi1 143.12 - L630 Nma 18 20 26 32 - 30 - „ A d 17 amani - 144.05 - L630 M- 142.18 - L520 - 30 142.17 - L630 19 - - - 11 ® , 19 1111 20 - �_ - ma 30 /r- 20 26 30 144.16 - L520 143.13 - L630 20/1 mama 12 30 /rfMI1111 142.08 - L520 - 22 144.06 - L630 20/1 13 11 14 143.06 - L520 OBIEIBLE21111 30 /r- - 1111 24 26 M1111111111 144.07 - L630 - E M-- ma M - -LN3! IMMEELIZEI 30 - 30 / 25 143.14 - L630 27 15 -ma 142.10 - L630 -1 - 2 LEI1111�J 29 III 30 20/1 29 143.15 - L630 30 144.08 - L630 30 34 - Ell ma IIMIIIIIERNIMIUIESI1 - 18 143.08 - L520 143.07 - L630 MI - 20/1 MEE 32 19 143.16 - L630 - - - 3° r -1111 IM 34 144.09 - L630 mg - - 30 34 I 37 42 -ma - -® - - .1E1 30 /r 35 -11111 39 1111 36 144.11 - L630 - - ° 30 .,/ 36 38 40 EN 143.17 - L630 1111 40 - -- - - 11111 J ma9�TN7�1�• SPARE SPARE SPARE 41 23 142.13 - L520 - - 20/1 41 ®I111moi mum SPACE ONLY M ®- 20/1 PDU 143.02 PANEL "143 02/ 1 " SCHEDULE FED FROM UPS B DP2B SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUND 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% NG 225 GROUND - GREEN PANEL MAY BE TOP OR GROUNDED NEUTRAL WHITE - MAIN BREAKER OR MAIN BREAKER RATING - BOTTOM FEED AT CONTRACTORS OPTION ASIINDICATED ONLY POLE NO. F 123 POLE NO. SERVES LOAD BREAKER POLE NO. 123" WO POLE SERVES LOAD BREAKE" 2 POLE NO. LEG AMPS LEG AMPS NO. 1 2 3 POLES 142.02 - L630 NO. 1 2 3 POLES 2 1 142.02 - L520 2 6 8 10 16 � I 20/1 1 ma NUMEI 2 142.14 - L520 - 20/1 20/1 5 2 3 142.03 - L520 ma - 3° _dallr ■ 2 30 / -1111 L171111K1J 9 20/1 3 142.13 - L630 142.14 - L630 1 4 142.15 - L520 20/1 - 7 9 20/1 142.04 - L630 4 5 142.04 - L520 7 9 1111 1111 - 20/1 5 1111 1111 6 142.16- L520 - I -1.111 - 20/1 - 6 7 142.05 - L520 - 1111 Rill 20/1 7 II11m1 1111 1 8 142.17 - L520 142.06 - L630 143.18 - L520 - 20/1 - 8 _ 9 142.06 - L520 18 20 26 32 - Effil IEIM 20/1 9 - - 10 142.18 - L520 - 142.17 - L630 20/1 - - 10 11 142.07 - L520 -I-. 17 - 20/1 11 - 11 12 143.05- L520 - 144.16 - L520 - 20/1 29 12 13 142.08 - L520 - IIIIIMMIIEISTII -- - - 20/1 13 11 14 143.06 - L520 - - 20/1 -iL- 14 15 142.09 - 1 520 Ell 20/1 15 1111ffl Eall WM 39 142.10 - L630 16 143.07 - L520 - - ME 3° .,d/rma11111 30 L.IIII 20/1 143.06 - L630 16 17 142.10 - L520 30 34 - 20/1 17 - 142.11 - L630 - 18 143.08 - L520 143.07 - L630 3r - 20/1 - 18 19 142.11 - L520 - - - 20/1 19 IM 41 20 143.09 - L520 - - 20/1 20/1 42 20 21 142.12 - L520 - - 20/1 20/1 21 SPARE SPARE - 22 143.10 - L520 20/1 20/1 20/1 29 31 33 11 111' 20/1 SPARE SPARE SPARE 22 23 142.13 - L520 20/1 30 - 20/1 ®I111moi 20/1 20/1 32 34 33 143.11 - L520 35 SPARE - 20/1 - 24 25 SPARE - - - 20/1 20/1 ®1 27 36 38 37 26 28 SPARE SPARE - 20/1 20/1 20/1 I III 26 28 27 SPARE 29 SPARE 20/1 39 20/1 29 SPARE 30 SPARE 40 41 - 20/1 30 31 SPARE - 42 20/1 31 0 20/1 32 SPARE 20/1 32 33 SPARE - 20/1 33 111 34 SPARE - 20/1 34 35 SPARE MEI - EMI 35 1111 36 SPARE 20/1 36 37 SPARE EMI - 20/1 20/1 37 IIIIO SPARE SPARE - - 20/1 20/1 38 40 39 SPARE WI1111 40 41 SPARE Mil 2011 rum 42 SPARE - 20/1 42 PDU 143.02 PANEL "143.02/2" S H E D U V V LE FED FROM UPS 28 DP2B SERVICE: 120/208V., 30 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING LEG 3 - BLUE 10 KVA BAR 35% 10,000 A. GROUND - GREEN GROUNDED PANEL MAY BE TOP OR NEUTRAL WHITE - MAIN BREAKER OR MAIN BREAKER RATING 225A. - BOTTOM FEED AT CONTRACTORS OPTION MAIN LUGS ONLY AS INDICATED POLE NO. SERVES LOAD BREAKER POLE NO. F 123 POLE SERVES LOAD BREAKER POLE NO. LEG AMPS LEG AMPS 1 2 1 2 - POLES 30 III NO. 1 2 POLES 142.02 - L630 - - 2 142.12 - L630 - 2 IIIIIIMEEEE ® - 30 30 30 MIMI= 3° /ran 2 6 8 10 16 � I 20/1 - ma NUMEI 3 11111121 - 20/1 4 5 142.03 - L630 5 142.03 - L630 ma - 3° _dallr ■ 2 30 / -1111 L171111K1J 9 1111 ° 10 142.13 - L630 142.14 - L630 - ma- - - 20/1 - 7 9 9 142.04 - L630 ma ma - 11 7 9 1111 1111 B 10 --p - 1111EILEaIIII@J 30 / 13 1111 14 142.15 - L630 - I -1.111 13 142.05 - L630 - ma �J 17 20/1 11 1111 Rill MEMIEE11111 3° /rir 19 II11m1 1111 16 20 20/1 12 142.06 - L630 143.18 - L520 - 142.16 - L630 - 20/1 � - - 30 IIIIMMIE 30 111- =MEI 30 18 20 26 32 19 Effil IEIM 142.07 - L630 ® - - 3° ..r -1111 - 142.17 - L630 20/1 - - 142.06 - L630 16 144.15 - L520 -I-. 17 L -1111 - - 20/1 17 142.08 - L630 - 144.16 - L520 ma M30 30 /rein111 / 29 1111 26 2B 30 142.18 - L630 143.05 - L630 - IIIIIMMIIEISTII -- - - 27 11111 20/1 19 Ersi J 142.09 - L630 - - - -iL- 21 1111�J 111 Ell 21 23 1111 111 1111ffl Eall WM 39 142.10 - L630 29 31 - - - ME 3° .,d/rma11111 30 L.IIII 36 143.06 - L630 -ma ma - 30 34 145.05 - L520 MOE 36 - 142.11 - L630 - 24 25 143.07 - L630 3r - - 25 2 39 IM 40 - - ma- - gill= 40 41 SPACE ONLY 34 - 36 - - - 20/1 41 42 SPACE ONLY 20/1 42 mama PDU 145.02 PANEL "145 02/1" SCHEDULE FED FROM UPS 2B DP2B SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING LEG 3 - BLUE 10 KVA BAR 35% 10,000 A. GROUND - GREEN PANEL MAY BE TOP OR GROUNDED NEUTRAL - MAIN BREAKER OR MAIN BREAKER RATING 225A. -WHITE BOTTOM FEED AT CONTRACTORS OPTION MAIN LUGS ONLY AS INDICATED POLE NO SERVES LOAD BREAKER POLE NO 1 123 HU HO POLE NO 2 SERVES LOAD BREAKER POLE NO LEG AMPS LEG AMPS 1 2 3 POLES 1 2 3 POLES 1 143.12 - L520 20/1 144.07 - L520 - 142.12 - L630 - 20/1 2 3 143.13 - L520 3 - 20/1 3 2 4 144.08 - L520 4 - 20/1 4 5 143.14 - L520 5 142.03 - L630 - 20/1 5 1111 5 144.09 - L520 6 - 142.13 - L630 - 20/1 6 7 9 143.15 - L520 143.16 - L520 7 ma ma 20/1 20/1 7 9 1111 1111 B 10 144.11 - L520 144.12 - L520 - - - 20/1 8 20/1 10 11 143.17 - L520 ma - 20/1 11 1111 10 - 144.13 - L520 20/1 12 13 143.18 - L520 - - 20/1 13 1111 111 1H1111011111.10 1111 14 144.14 - L520 - ® 20/1 20/1 14 16 15 144.02 - L520 - - 20/1 15 142.06 - L630 16 144.15 - L520 17 144.03 - L520 - - 20/1 17 IIII 18 144.16 - L520 L�I111 -1111 4 J 2 6 - 20/1 18 19 144.04 - L520 - 25 142.08 - L630 20/1 19 20 144.17 - L520 - 20/1 20 21 144.05 - L520 111 20/1 21 23 1111 111 22 144.18 - L520 29 31 - . 20/1 22 23 144.06 - L520 30 - 143.05 - L630 20/1 24 145.05 - L520 3o J 30 2 20/1 24 25 SPARE - 20/1 25 III 26 145.06 - L520 - - - 20/1 26 27 SPARE 34 - 36 - - - 20/1 27 35 } 37 28 145.07 - L520 143.07 - L630 - 38 20/1 28 29 31 SPARE SPARE - -- 39 20/1 20/1 20/1 29 31 33 11 111' 30 32 34 SPARE SPARE SPARE - - 20/1 30 SPACE ONLY _ 20/1 20/1 32 34 33 SPARE 35 SPARE SPACE ONLY - 20/1 35 42 SPARE - - 20/1 ma 20/1 36 38 37 SPARE - ® 20/1 37 I III 3s 39 SPARE 20/1 39 1111 40 SPARE - ma 20/1 40 41 SPARE 20/1 41 42 SPARE 0 20/1 42 PDU 145.02 PANEL "145.02/2" SCHEDULE FED FROM UPS 28 DP2B SERVICE: 120/208V.. 30 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN GROUNDED PANEL MAY BE TOP OR WHITE - MAIN BREAKER OR MAIN BREAKER RATING 225A. NEUTRAL - BOTTOM FEED AT CONTRACTORS OPTION MAIN LUGS ONLY AS INDICATED POLE NO. SERVES S AD BREAKER POLE POLE 123 PALE NO. LOAD BREAKER AMPS POLE NO. LEG AMPS LEG 1 2 3 POLES 11 1 2 3 POLES 1 142.02 - L630 3 a 1 z 142.12 - L630 - 30 2 3 2 3 11 4 5 142.03 - L630 - 3 a 5 1111 6 - 142.13 - L630 - 30 / 6 7 8 9 142.04 - L630 3 © 1111 10 - 142.14 - L630 3 0 10 EN r 14 16 20 ME 26 11 - - 30 / MEE 3a /-1111 30 13 15 19 111111111 1111 111 1H1111011111.10 1111 12 _ 14 - 18 ' 20 _ 142.15 - L630 142.16 - L630 142.17 - 1630 - 30 30 . /ram 3° .,,/ 142.05 - L630 15 - - ... 17 ` 142.06 - L630 19J - 21 142.07 - L630 - 23 J 2 L�I111 -1111 4 J 2 6 - 142.18 - L630 - - 25 142.08 - L630 3° 401r 30 4 27 - -. L 111 28 29 31 142,09 - L630 . - 30 29 30 - 143.05 - L630 3o J 30 2 32 _ - 3a Irk 32 36 33 142.10 - L630 - - - 30 dr 3 ° -1111 11111 r -111® 34 - 36 - 143.06 - L630 - 35 } 37 142.11 - L630 38 - 143.07 - L630 30 38 39 - Jr- 2 39 40 _. - I 40 41 SPACE ONLY _ - 20/1 41 42 SPACE ONLY - 20/1 42 GENERAL NOTES: 1. PANEL SCHEDULES INDICATED ON THESE DRAWINIGS ARE PROVIDED WITH PDU BY PDU MANUFACTURER WITHOUT THE SPECIFIED BRANCH BREAKERS. CONTRACTOR SHALL PROVIDE BRANCH BREAKERS INDICATED HEREIN. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC LL I-t13 11 IuuJ atya Tukwila OUTLET SHALL BE NEMA L5 -20R RECEPTACLE MOUNTED IN OUTLET BOX. DO NOT ANCHOR BO -9-T L T YO • CONCRETE FLOOR. 2. FOR EACH L520 CIRCUIT INDICATED, CONTRACTOR SHALL PROVIDE 2- #10'S, 1410 GND. IN 3/4" "SEAL TITS" FLEXIBLE CONDUIT FROM PDU TO OUTLET MOUNTED BENEATH THE DESIGNATED ELO9 0(0 3. FOR EACH L630 CIRCUIT INDICATED, CONTRACTOR SHALL PROVIDE 2- #10'S, 1- #10 GND. IN 3/4" "SEAL -TITE" FLEXIBLE CONDUIT FROM PDU TO OUTLET MOUNTED BENEATH THE DESIGNATED RACK. OUTLET SHALL BE NEMA L6 -30R RECEPTACLE MOUNTED IN OUTLET BOX. DO NOT ANCHOR BOX TO CONCRETE FLOOR. 4. FOR EACH CIRCUIT, PROVIDE LABELS TO IDENTIFY. RACK NUMBER AND CIRCUIT NUMBER AT BOTH ENDS OF CIRCUIT CONDUIT. ALSO, PROVIDE LABEL ON OUTLET COVERPLATE TO IDENTIFY CIRCUIT NUMBER AND PDU PANEL. RECEIVED CITY OF TIJKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT C© 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 3 1 Ol0 nO; In 1- W 2 u1 u Z Fr, Rd W, 4 Wo IIIII 1 W: > J� W � Zmm 2 3 Date: 12 -2 -08 Revision 01 -05 -09 95% REVIEW Project No. WTA. 08093 Sheet No. E- 100% CD ADD. NO. 1 PERMIT SET 4 ELECTRICAL PANEL SCHEDULES PDU 164.01 PANEL "164 01 /3" SCHEDULE FED FRO UPS . DP2B SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD A. M. L. O. BUS RATING MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDI 10.000A. LEG 3 - BLUE 10 KVA BAR 35% G G 225 GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED Al NEUTRAL - WHITE CONTRACTORS OPTION MAIN BREAKER OR MAIN BREAKER RATI MAIN LUGS ONLY AS INDICATED LOAD POLE NO. SERVES LOAD BREAKER 12 3 POLE LOAD B'EAKERI - ' POLE MillEallilli 1 111111111M AMPS POLE LEG MI NO. POLES NO. 1 I1 II1 2 3 POLES 20/1 . NO. • 1 167.01 - L630 -�� 30 167.11 - L630 - 166.05 - L520 N 3° EWEN IrE 5 - - - - 1.1111 20/1 2 3 SPACE ONLY 3 MI -- S- 167.02 - L630 -- - 30 ..11ir�I11I SPACE ONLY NN 6 167.12 - L630 - - - ____ 30 IM 6 J 4 ' - MillIIRIER1111 6 SPACE ONLY 8 IMIIIIIIIMININI - - -larall? 8 9 167,03 - L630 - - - 30 _ 9 1111 10 167.13 - L630 9 SPACE ONLY 7 30 4 10 11 MIIININNINNIN -NE - - iI SPACE ONLY SPACE ONLY IIl1 12 -® io 12 - VallIMILA 30 1 14 111EINIMMINIII=111 WM 167.04 - L630 167.05 - L630 - - 10 12 30 A il 13 mum IIII- IIII 167.14 - L630 - - 1111 as - - MIN - - 14 _ L1111 20/1 17 Il1I -- SPACE ONLY --�'�? 20/1 30 JidE11I1I 20/1 1 167.15 - L630 SPACE ONLY - - 30 EMI 18 20/1 20/1 - 111® 20 PY.IIMIREE.1111 - 2 ° Millill.1111 - - 1 1111► - �� 21 20 EN IHRIIIMIIIIIIIIMININ mu IrEJ 1 167.06 - L630 167.07 - L630 - - - IN -- - - 30 Jreaniu�1i MINEILVE11111113111 30 _iiIiraiIIII - 26 167.01 - L630 _ - - - 30 MILER 20/1 - 20/1 23 rmicr1 30 26 167.02 - L630 -® - - En= 20/1 - ' Ell MAIM 27 1111' 28 ll �E 25 27 =UM ®Ii ... AI ?I 167.08 - L630 -- - - 30 / 29 1111 30 167.03 - L630 IN - 30 - 30 30 31 1111101111111111111111111111 - - mum ALE- I11111ZIPJ SPACE ONLY - __dill N ® fradmi?Iags - 3° l /it N 167.09 - L630 - -® SPACE ONLY 3° _Al 33 II11 1E1B1 SPARE 33 35® 34 SPACE ONLY -M® _ 1.11a1111111 35 1111 36 34 � - 11111Virdllr 36 Nig! 167.10 - L630 - - .11 _Allirl -IIII 1 SPARE - - 30 IMIl 38 SPACE ONLY SPACE ONLY - M =MIMI 39 IIII 40 MIIIIIIIIIMMIONI - - MIIMNIIII 40 41 SPACE ONLY ® MI - 20/1 EININ,KEN SPACE ONLY -�M 0/1 IM PDU 164.01 PANEL "164.01/4" SCHEDULE FED FROM UPS2BDP2B SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED AT NEUTRAL - WHITE CONTRACTORS OPTION - MAIN BREAKER OR MAIN BREAKER RATING 225A. MAIN LUGS ONLY AS INDICATED POLE NO. SERVES LOAD BREAKER POLE NO. 1 12 POLE SERVES LOAD BREAKER POLE NO. LEG AMPS LEG POLE NO. 2 LEG AMPS NUM II" 1 2 3 POLES 20/1 3 - 2 3 POLES 1 SPACE ONLY - 166.05 - L520 20/1 SPACE ONLY - - EN - - 20/1 2 3 SPACE ONLY 3 - -- 20/1 IONIAll 20/1 4 SPACE ONLY NN 20/1 20/1 4 6 5 SPACE ONLY - 20/1 4 20/1 mum - 6 SPACE ONLY 7 SPACE ONLY - 1 6 20/1 7 MI 8 SPACE ONLY - = 166.08 - L520 20/1 8 9 SPACE ONLY 7 - - 20/1 20/1 9 11 MI IIII 10 12 SPACE ONLY SPACE ONLY 20/1 20/1 20/1 io 12 11 SPACE ONLY 20/1 13 15 17 SPACE ONLY SPACE ONLY SPACE ONLY - 10 12 - - 20/1 20/1 13 15 IIII- IIII 16 SPACE ONLY SPACE ONLY - 1111 as - - 20/1 20/1 14 16 20/1 17 Il1I 18 SPACE ONLY 20/1 20/1 N 20/1 18 19 SPACE ONLY - 17 19 20/1 20/1 19 mum 1111 20 SPACE ONLY - 18 20 20/1 20/1 20/1 20 21 SPACE ONLY 167.11 - L520 167.12 - L520 - 165.02 - L520 22 SPACE ONLY 16 18 - ■ 20/1 22 23 SPACE ONLY - 20/1 19 20/1 23 20 24 26 30 SPACE ONLY SPACE ONLY SPACE ONLY - - En= 20/1 20/1 20/1 20/1 24 26 28 25 SPACE ONLY - - ll 20/1 20/1 20/1 25 27 =UM 1111 lfl MEE 27 29 SPACE ONLY SPACE ONLY - - Ea SPACE ONLY -- 23 - 20/1 30 31 SPACE ONLY - SPARE - 20/1 mum 20/1 32 SPACE ONLY - 28 - 20/1 32 33 SPACE ONLY 28 30 - SPARE 20/1 33 IIII 34 SPACE ONLY -M® WM 11111 20/1 34 35 37 SPACE ONLY SPACE ONLY - 31 - 20/1 20/1 35 37 1111 1111 36 38 SPACE ONLY SPACE ONLY - M - 20/1 36 20/1 38 39 SPACE ONLY 33 SPARE 33 20/1 39 11 1 40 SPACE ONLY SPACE ONLY - E MI _ 20/1 20/1 40 42 41 SPACE ONLY 34 35 - 20/1 41 SPARE 20/1 42 PDU 164.01 PANEL "164.01/2" SCHEDULE FED FROM UPS 2B DP2B SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED AT NEUTRAL - WHITE CONTRACTORS OPTION -- MAIN BREAKER OR MAIN BREAKER RATING 225 A. MAIN LUGS ONLY AS INDICATED POLE NO. SERVES LOAD BREAKER POLE NO. 123 POLE SERVES LOAD BREAKER POLE NO. LEG AMPS LEG AMPS POLE NO. i LEG NO. • 2 3 POLES 3 - 2 1 2 3 POLES 1 166.05 - L520 20/1 1 2 167.04 - L520 - .-- )1t - 20/1 2 3 166.06 - L520 4 -__ 8 - �MN 20/1 3 _ 4 6 4 167.05 - L520 - - - 20/1 4 5 166.07 - L520 - .111 - 20/1 5 164.08 - L520 1 6 167.06 - L520 20/1 KNIm - 20/1 6 7 166.08 - L520 EN 20/1 10 20/1 7 - 1 8 167,07 - L520 - 142.08 - L630 12 20/1 8 9 166.09 - L520 20/1 20/1 .. 13 20/1 9 143.11 - L630 1 I 10 12 167.08 - L520 167.09 - L520 1 M 14 - 20/1 20/1 io 12 11 166,10 - L520 ® 20/1 - 20/1 11 13 166.11 - L520 - -IIM 20/1 20/1 13 164.14 - L520 1 14 167.10- L520 - 17 19 20/1 14 15 166.12 - L520 11 - 18 20 20/1 20/1 15 17 - I I 16 18 167.11 - L520 167.12 - L520 21 165.02 - L520 /.rlw 30 20/1 20/1 16 18 17 166.13 - L520 19 167.01 - L520 166.03 - L520 ® - 20/1 19 22 1 20 167.13 - L520 - - 20/1 20/1 20 21 167.02 - L520 26 - - 20/1 20/1 20/1 21 2324 25 25 1 22 26 167.14 - L520 167.15 - L520 167.16 - L520 - - - 20/1 20/1 20/1 22 24 26 23 167.03 - L520 - 25 SPARE 26 28 27 SPARE NM 30 .JI 20/1 27 1111 28 28 167.17 - L520 - 29 20/1 _ 28 30 29 SPARE 20/1 29 - 20/1 29 -M® WM 30 SPARE 30 31 SPARE 20/1 31 SPARE - MIIIII 39 20/1 31 - IIII 32 SPARE 32 33 SPARE 20/1 32 33 SPARE 33 - 30 ,.didifiE31 „ 20/1 33 - E 34 SPARE 3 5 - 20/1 34 35 SPARE 3 6 SPARE 20/1 35 ME 20/1 36 SPARE SPARE - - 20/1 36 37 SPARE - SPARE - 20/1 37 20/1 38 38 SPARE - - - 20/1 38 39 SPARE SPARE - 20/1 39 • 41 40 SPARE - 20/1 20/1 40 41 SPARE _ - 20/1 20/1 41 42 SPARE - 20/1 42 PDU 164.01 PANEL "164.01/1" SCHEDULE FED FROM UPS2BDP2B SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED AT NEUTRAL - WHITE CONTRACTORS OPTION - MAIN BREAKER OR MAIN BREAKER RATING 225A. MAIN LUGS ONLY AS INDICATED POLE NO. SERVES LOAD BREAKER POLE NO. 1� 123. POLE POLE NO. F LOAD BREAKER POLE NO. LEG AMPS POLES 20/1 LEG AMPS POLES POLE NO. i LEG 1 - 2 -- EN II ir O• NO. 3 - 2 1 - 1 164.04 - L520 165.04 - L520 . - ® 142.03 - L630 20/1 2 3 164.05 - L520 .-- )1t - - - 20/1 3 1111 1111 4 -__ 8 165.05 - L520 165.06 - L520 �MN - - - 20/1 20/1 4 6 7 164.06 - L520 164.07 - L520 - - �� - 20/1 20/1 Minn 7 165.07 - L520 - 30 .111 20/1 8 9 164.08 - L520 - -® 30 � 20/1 KNIm 10 165.08 - L520 ®In= IIIH -- 20/1 10 11 164.11 - L520 - IIII - 20/1 11 142.08 - L630 12 165.10 - L520 - - --- _1111. 26 20/1 20/1 12 14 13 164.12 - L520 - 143.11 - L630 - 20/1 13 1 M 14 165.11 - L520 15 164.13 - L520 143.05 - L630 - r - 20/1 15 1111 16 165.12 - L520 J - -IIM 20/1 16 17 164.14 - L520 143.12 - L630 0 Or 35 M1 0 20/1 17 19 1111 1111 1 8 20 165.13 - L520 165.14 - L520 - ®1.11 - 20/1 20/1 18 20 19 165.01 - L520 - -- 30 Jr>�IlII 20/1 21 165.02 - L520 /.rlw 30 11. : o � '" 38 re E 40 I -11 42 20/1 113-1111 SPACE ONLY 22 166.03 - L520 ® - - 20/1 22 23 165.03 - L520 M1 MI b1 - 20/1 23 I111EN 3° /L1 166.04 - L520 26 144.07 - L630 143.15 - L630 20/1 24 25 SPARE 30 31 - 20/1 25 1111 2 6 SPARE - - 11111M11111 20/1 20/1 26 28 27 SPARE NM 30 .JI 20/1 27 1111 28 SPARE 30 - 29 SPARE 36 - - 20/1 29 1111 30 SPARE -M® WM 143.16 - L630 20/1 30 31 SPARE - ® IEiil 20/1 MIIIII 39 32 SPARE - IIII NM 20/1 32 33 SPARE �� -- - - - - 20/1 33 IIIINI- 30 ,.didifiE31 „ SPARE -- - E 20/1 34 3 5 SPARE -- 20/1 MIMI 3 6 SPARE -- ME 20/1 36 37 SPARE - -- 20/1 MINN 38 SPARE - - 20/1 38 39 SPARE - - 20/1 39 1111 40 SPARE - 20/1 40 41 SPARE - 20/1 41 42 SPARE - 20/1 42 PDU 145.16 PANEL 1 1 145.16/1" SCHEDULE FED FFIOMUP•2BDP2B A. . SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATIN3 MINIMUM CIRCUIT BREAKER LEG 1- BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10 0 00 A. LEG 3 - BLUE 10 KVA BAR 35% 22• GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED AT NEUTRAL - WHITE CONTRACTORS OPTION - MAIN BREAKER OR MAIN BREAKER RATING MAIN LUGS ONLY AS INDICATED LOAD POLE NO • SERVES LOAD BREAKER AMPS POLE NO. F 1 BREAKER AMPS SERVES 142.12 - L630 LOAD BREAK; EM LEG 3 POLE NO. i LEG POLE AMP - ' D NO • POLE I ° E r 2 ■ II EN II - w - 3 - POLES _ 30 1 - 2 3 1 142.02 - L630 - ® 142.03 - L630 Ell �MN - EMI - - M -- - Mil - -�® - 30 - 3° / 1 3° / 30 4 .-- )1t IIII 1111 IIII�IJ 1111 - - �J 6 10 16 18 20 142.13 - L630 142.14 - L630 - - - - - - - - III 0 0 aL 14 1 16 E° Wry 0 MINE 20 10 er,I■ mom 24 I0 26 MINE 28 Lo _ 30 MOMMONO NENZWRNIElaviniq 142.04 - L630 11J 1 142.05 - L630 5 MN IIII 1111 6 8 �f�111IiLil - 'iL .iAlinill111 MIME 19 142.15 - L630 IIIIIIIMIIIIMMIIII 142.16 - L630 u1 144.14 - L630 19 1 142.06 - L630 144.02 - L630 30 - 21 142.07 - L630 - - - 3° .agill131111I1�1i 30 � -� - 142.17 - L630 10 - 30 4 IIIH -- - LMINEILMI1111 144.03 - L630 24 - miml 12 - m1 142.08 - L630 - -- - 30 IlliMMIIIII 3° JfiEIIII11I 27 MIME 26 142.18 - L630 - - 12 27 143.11 - L630 - 29 142.09 - L630 -- - -- - - - - 30 29 IIII 30 143.05 - L630 -- - ® --1- r - - ETIMINIIIIIIMINNIN 1 142.10 - L630 MEE 31 3° r IlI1 I1111 J 143.06 - L630 -IIM 11111 1 143 - L630 16 18 - 143.12 - L630 0 Or 35 M1 0 - - IIIM - MIMI 35 IIII 36 20 1 - PIE 36 142.11 - L630 ■ I - Mil 30 Jr>�IlII 1 40 143.07 - L630 - /.rlw 30 144.18 - L630 : o � '" 38 re E 40 I -11 42 24 - r�Lil1II SPACE ONLY -- - N■IIII 42 SPACE ONLY 23 IIII�J - _-. PDU 145.16 PANEL "145.16/2 SCHEDULE FED FROMUPS2BDP2B SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED AT NEUTRAL - WHITE CONTRACTORS OPTION - MAIN BREAKER OR MAIN BREAKER RATING 225A. MAIN LUGS ONLY AS INDICATED POLE NO. SERVES LOAD BREAKER POLE NO. 12 POLE SERVES LOAD BREAKER AMPS NO. LEG AMPS MINN PQLE NO. LEG 1 2 3 POLES 1 - I® -® POLES 30 1 143.08 - L630 - �_ 30 - � - ® ICI 2 143.18 - L630 - - - - ELI -IIII 30 _AMMO OWNIIIILENIIIIKIM 4 _ IIII 6 EMI - 30 I LN L=- 6 5 MN 143.09 - L 630 6 8 7 - 30 .,r�II1I 144.14 - L630 - 6 144.02 - L630 30 - EN - - 2 LI- 9 1111QJ IM - 30 � -� - -/ - - 10 - 30 4 IIIH 9 143.10 - L630 10 144.03 - L630 30 - miml 12 13 - E,-- L�IIII@J_ 30 IlliMMIIIII -- 143.11 - L630 - mot 12 13 143.11 - L630 - -- -- 3° _AA MIIIIMEN 144.04 - L630 - - - -- - ® --1- r - 30 /raill /., - 3° _Addr 16 20 MT J - -- - - - MNIMILE131111 30 /N 11111 1 143 - L630 16 18 144.05 - L630 143.12 - L630 19 MIME 30 JlinI11II - 1111 24 2 2 18 1111 20 1 143.13 - L630 WANE 30 d .41611111111 -- IIIIIIMMININIIMININI 30 _ 143.14 - L630 22 144.06 - L630 - -- /.rlw 30 144.18 - L630 3o -F0111 �� 24 I - - IIII 23 IIII�J - M1 MI b1 143.14 - L630 - -- EMI 3° /L1 -IIII 26 144.07 - L630 143.15 - L630 - 30 26 30 31 - - - 27 IIII IIIIMENI - - 11111M11111 145.06 - L630 28 143.15 - L630 3° rEE1111♦1 NM 30 .JI 143.16 16 - L630 1 3 ° _ 144.08 - L630 �� - 30 30 35 1111 36 i - - - 36 144.09 - L630 - � � - - - - -- 3° ..dedrl�- 32 36 WM 143.16 - L630 - 143.17 - L630 30 ., 33 il1 IEiil _ _.1dIME1 39 _ � I IIII 36 41 39 41 143.17 - L630 ` ' • ' - �� -- - - .addrE IIII i1 40 I 42 144.11 - L630 -- 30 ,.didifiE31 „ 40 MOM 39 II �II•I - E SPACE ONLY ��ME 42 PDU 145.16 PANEL "'145:16/3' SCHEDULE FED FROM UPS 2B DP2B SERVICE: 120/208V.. 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED AT NEUTRAL - WHITE CONTRACTORS OPTION MAIN BREAKER OR MAIN BREAKER RATING 225A. MAIN LUGS ONLY AS INDICATED POLE NO. Mal SERVES LOAD BREAKER POLE NO. - t11IIi 123 ��� POLE - LOAD BREAKER LEG AMPS LEG POLE AMPS © - 11111 POLES 30 ■- NO. 2 I 1 2 3 POLES NO. 144.12 - L630 - 143.08 - L630 - ® - - Ell 30 - 1 144.13 - L630 - - NM - 30 _AMMO OWNIIIILENIIIIKIM IIII 6 143.09 - L630 !l® - 30 . . 6 8 7 9 144.14 - L630 - - - 30 9 1111 10 143.10 - L630 - - 30 � __ 10 - - PINIENRIiTi IIIH J - - miml 12 13 144.15 - L630 E,-- 30 IlliMMIIIII 14 143.11 - L630 - 3° �1 -- -- IIDLiIIII 16 ® �� ®-_' -- ' - - MIN 3° ■ailiEN 20 144.16 - L630 - -- 30 JrI�111i 1 143 - L630 19 IMITION 144.17 - L630 - NM -- _ MIME 30 JlinI11II 19 1111 24 2 2 143.13 - L630 RINI @J Nal 30 WI 26 -- ® WANE 30 d .41611111111 23 IIIIIIMMININIIMININI 143.14 - L630 -- - - /.rlw 30 144.18 - L630 26 27 -MI MI1111 27 IIII 28 111111111•11 28 29 145.05 - L630 I= EMI 30 ...iiil 29 IIII 30 143.15 - L630 -- - - 30 / 30 31 - - MAID 31 IIIIMENI INNIPPPIIIMMI - 30 145.06 - L630 - - - 3° rEE1111♦1 34 143.16 16 - L630 MI - 35 MIIIIIIIIII -NM - 35 1111 36 - - - 36 1 39 145.07 - L630 - -- 30 rIIII 38 143.17 - L630 - -- 30 38 - - _ _.1dIME1 39 1111 40 41 MILMx�7MIME._ - 41 IIII 4 SPACE ONLY MIM- 42 1 01 -05 -09 95% REVIEW 2 01 -15 -09 100% CD 3 01 -26 -09 ADD. NO. 1 4 02 -02 -09 PERMIT SET PDU 145.16 PANEL' 45.16/4" SCHEDULE FED FR. SERVICE: 120/208V., 30, 4W. MINIMUM CIRCUIT BREAKER INTERRUPTING CAPACITY 10,000 A. PANEL MAY BE TOP OR BOTTOM FEED AT CONTRACTORS OPTION CONDUCTOR COLOR CODE LOAD 10 KVA 10 KVA 10 KVA LEG 1 - BLACK LEG 2 - RED LEG 3 - BLUE GROUND - GREEN GROUNDED NEUTRAL - WHITE MAIN BREAKER OR MAIN LUGS ONLY AS INDICATED M. L. O. BUS RATING A. SEPARATE GROUN • ING BAR 35% MAIN BREAKER RAT NG 225 POLE NO NMI NEM EMI M.1 EMI EMI Elabl NEM EMI NEMMENII mil 143.18 - L630 -- E� 144.02 - L630 �- 1 144.03 - L630 in 1 144.04 - L630 - MIME SE MN MINN El MN MI --- MINN - - IMAM 41 SERVES 144.05 - L630 144.06 - L630 144.07 - L630 144.08 - L630 144.09 - L630 144.11 - L630 SPACE ONLY LOAD 2 BREAKER 30 30 30 30 30 30 30 AMPS POLE 123 POLE LOAD :REAKE POLES NO. ■••■ NO. SERVES . AMPS 11 NO. ■�.rr�.IIII ® 3 POLES III 1 144.12 - L630 EN IIME �IIMEN ©LNEMIIIIiIJ --- �I17L� imiliffi11111 6 144.13 - L630 IIIII `„ 11111PBE - IIIIQJ - DEL 9 1111 10 144.14 - L630 - - - BMW WAIIIIIIIL1I111 -J -- /V.IIIIIEL Jrsm111I- 144.15 - L630 --- Qr'vrm MIIMILIESII1111 16 - _ 30 i1rior IIII _ 18 144.16 - L630 1.1 _ E'121131 19 1111 20 IN 11111MINIEE 3° _Ariir1m11IIrgi1 144.17 - L630 -- Imam. MINIFILIEE1111111EINIIIIIIIIMININ111111 -- Wr1LQ- IiillillIMIIIMil 144.18 - L630 - 111111EME _iL IIII 28 - ri F?LVII 2 9 1111 30 145.05 - L630 -- um _iLIIIIIEEN -- MINED Lem111IN 145.06 - L630 No -��ir� - - �-��E. .fir 1111 11 145.07 - L630 - -- 3./11 39 IIII 40 M - ���E MOM 41 1I„ 42 SPACE ONLY - -1I 10 16 26 30 42 GENERAL NOTES: 1. PANEL SCHEDULES INDICATED ON THESE DRAWINIGS ARE PROVIDED 11TH PDU BY PDU MANUFACTURER WITHOUT THE SPECIFIED BRANCH BREAKERS. CONTRACTOR SHALL PROVIDE ALL BRANCH BREAKERS INDICATED HEREIN. 2. FOR EACH L520 CIRCUIT INDICATED, CONTRACTOR SHALL PROVIDE 2- #10'S, 1 410 GND. IN 3/4" "SEAL -TITS" FLEXIBLE CONDUIT FROM PDU TO OUTLET MOUNTED BENEATH THE DESIGNATED RACK. OUTLET SHALL BE NEMA L5 -20R RECEPTACLE MOUNTED IN OUTLET BOX. DO NOT ANCHOR BOX TO CONCRETE FLOOR. 3. FOR EACH L630 CIRCUIT INDICATED, CONTRACTOR SHALL PROVIDE 2- #10'S, 1- #10 GND. IN 3/4" "SEAL -TITE" FLEXIBLE CONDUIT FROM PDU TO OUTLET MOUNTED BENEATH THE DESIGNATED RACK. OUTLET SHALL BE NEMA L6 -30R RECEPTACLE MOUNTED IN OUTLET BOX. DO NOT ANCHOR BOX TO CONCRETE FLOOR. 4. FOR EACH CIRCUIT, PROVIDE LABELS TO IDENTIFY. RACK NUMBER AND CIRCUIT NUMBER AT BOTH ENDS OF CIRCUIT CONDUIT. ALSO, PROVIDE LABEL ON OUTLET COVERPLATE TO IDENTIFY CIRCUIT NUMBER AND PDU PANEL. ELO9OIo 1 REVIEWED Ai CODE COMPW PA70 -NE CO OfTulcw ili t iLD _N IN RECEIVED CITY OF TUKWILA FEB 0 5 2000 PERMIT CENTER 1 11 LUui WTA - 08093 COPYRIGHT ©2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Av 1 W 3 r NAG M - 4k: � tic 9 • t,, >. zG /sT WONAI Expir Sheet No. Fac. Code :TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision Project No. WTA. 08093 E -15 ELECTRICAL PANEL SCHEDULES co [ (.D :5 `V PDU 166.01 PANEL X 66.01/4 SCHEDULE FED FROM U 1A UPP1 SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED T NEUTRAL - WHITE CONTRACTORS OPTION - MAIN BREAKER OR MAIN BREAKER RATING 5A. A D UGS ONLY AS S MAIN INDICATED POLE SERVES LOAD BREAKER POLE NO 1 23 POLE SERVES LOAD BREAKER L E L P DE DI N . LEG AMPS 12.21 POLE NO. r LEG AMPS 1 2 3 POLES 1 2 NO 1 2 3 POLES 1 SPACE ONLY - 167.11 - L630 PO 20/1 1 2 SPACE ONLY 4 20/1 20/1 MI 3 SPACE ONLY - - 3 20/1 3 . 167.12 - L630 4 SPACE ONLY - ( 2d/1 3 - 5 SPACE ONLY ...iiiiiillill CHILLER #1 - 20/1 5 MI NEM 6 SPACE ONLY 8 9 - 2d/1 f) 7 SPACE ONLY - 1111 10 20/1 7 - 9 8 SPACE ONLY - 8 io 13 2d/1 2d/1 1A 9 SPACE ONLY 3 ��IIfl - - 20/1 s - 12 10 SPACE ONLY 14 - 11 SPACE ONLY - - 20/1 11 16 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIImgor 12 SPACE ONLY 20/1 12 - 2d/1 12 1 3 SPACE ONLY - 30 17 20/1 13 ` 165.12 - L520 165.13 - L520 14 SPACE ONLY ' 18 19 201 ;i 15 SPACE ONLY 2L19 - 1111 20/1 15 - 16 SPACE ONLY 20 - - 216 1 2d11 1� i 17 SPACE ONLY 21 - 20/1 17 - 18 SPACE ONLY 23 19 SPACE ONLY - VIII, 25 27 29 Ilmum 2 20/1 19 24 - IIIII 20 SPACE ONLY SPACE ONLY - 27 - 2d(1 20(1 20/1 zQ 2 2 21 SPACE ONLY 31 - 25 20/1 21 167.05 - L630 - 22 23 SPACE ONLY L 26 27 - 20/1 23 IIn r . 24 SPACE ONLY 25 SPACE ONLY - - EN1111 20/1 25 29 167.08 - L630 26 SPACE ONLY - 3� 29 2011 2;6 27 SPACE ONLY U10 2 a 30 31 40 - 28 SPACE ONLY 111111111FOINE - PDU 164 LANTRONIX 20/1 28 29 SPACE ONLY SPACE ONLY - SPARE 32 I 20/1 31 - 30 32 SPACE ONLY SPACE ONLY - 36 20`1 20(1 31° 32 31 33 SPACE ONLY 34 36 - 20/1 33 37 167.10 - L630 34 SPACE ONLY 32 30 117111111 201 3� 35 SPACE ONLY • - 20/1 35 - 36 SPACE ONLY 2 39 SPARE 20 1 3g 37 SPACE ONLY - I 40 20/1 37 38 SPACE ONLY 41 37 42 20/1 38 39 SPACE ONLY 20/1 - 20/1 39 - 40 SPACE ONLY 38 - SPARE 20`1 4'0 41 SPACE ONLY - 20/1 41 42 SPACE ONLY 40 41 SPARE 20/1 42 PDU 166.01 PANEL "166.01/3" SCHEDULE FED FROMUPSIAUPP1 SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED AT NEUTRAL - WHITE CONTRACTORS OPTION - MAIN BREAKER OR MAIN BREAKER RATING 225A. MAIN D UGS ONLY AS INDICATED POLE NO. SERVES LOAD BREAKER POLE N. rl�O'�II 1 23 SERVES SERVES LOAD BREAKER POLE NO. LEG AMPS MEM POLE NO. r LEG AMPS 1 2 3 POLES 1 2 3 POLES 1 167.01 - L630 - - 1 30 2 167.11 - L630 PO - 1 30 2 4 20/1 1 MI 167. - L630 165.04 - L520 - 20/1 3 21/1 Ins 167.12 - L630 3 164.05 - L520 3 ( 7 3 - 4 165.05 - L520 ...iiiiiillill CHILLER #1 ®11E/1 - ®ME/1 $ 6 MI NEM 298.8 5 7 164.06 - L520 164.07 - L520 8 9 167.03 - L630 20/1 20/1 5 7 - 30 9 1111 10 167.13 - L630 WM to •= mil KM K NZ Ell I� - 9 30 � 10 12 11 8 io 13 167.04 - L630 - 11 164.11 - L520 3 ��IIfl 11 - 1142 167.14 - L630 - 12 165.10 - L520 3 4 14 15 13 164.12 - L520 - mmigignII♦I 20/1 =um 16 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIImgor 165.11 - L520 - 20/1 12 16 17 167.05 - L630 164.13 - L520 - 30 17 15 17 18 167.15 - L630 165.12 - L520 165.13 - L520 - 30 18 19 166.12 - L520 19 165.01 - L520 - 2L19 1111 20 1111 - 165.14 - L520 20 21 167.06 - L630 166.13 - L520 30 21 011 22 167.04 - L630 18 - 30 22 23 - - 20/1 20/1 20/1 20/1 VIII, 25 27 29 Ilmum 2 23 166.04 - L520 SPARE SPARE SPARE 24 - IIIII - - 25 SPARE 27 24 25 167.07 - L630 29 SPARE 31 30 25 26 167.05 - L630 - IIIII - _ _ Eggf®I 4 - 30 L 26 27 22 20/1 - IIn 2 27 35 28 - - EN1111 - 28 29 167.08 - L630 KM 37 39 SPARE SPARE 3� 29 37 30 167.06 - L630 SPARE U10 2 a 30 31 40 - 28 167.17 - L520 111111111FOINE 31 PDU 164 LANTRONIX 3 2 20/1 41 SPARE SPARE 32 33 1 167.09 - L630 - - 30 33 1111111111 LiII11 36 SPARE - - 30 MEE 34 36 35 32 SPARE 37 167.10 - L630 - 20/1 32 30 117111111 38 SPARE - • 30 38 39 - - 20/1 2 39 SPARE 40 - - I 40 41 SPACE ONLY - 20/1 41 37 42 SPACE ONLY - 20/1 42 PDU 166.01 PANEL "166.01/1" SCHEDULE FED FROM UPS 1A P1 SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING 225A. MAIN LUGS ONLY AS INDICATED MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND - GREEN PANEL MAY BE TOP OR GROUNDED BOTTOM FEED AT NEUTRAL -WHITE CONTRACTORS OPTION - MAIN BREAKER OR MAIN BREAKER RATING MAIN LUGS ONLY AS INDICATED POLE NO POLE NO SERVES LOAD BREAKER POLE NO. 12 3 POLE SERVES LOAD BR ER ,A 1 LEG AMPS LEG AMPS 1 2 3 POLES POLES 20/1 NO. 1 3 PO ES 1 164.04 - L520 - - 20/1 1 MI 2 165.04 - L520 - 20/1 207.84 21/1 Ins 167.05 - L520 3 164.05 - L520 - 4 20/1 3 110 4 165.05 - L520 20/1 CHILLER #1 ®11E/1 - ®ME/1 21/1 2./1 2d/1 6 MI NEM 298.8 5 7 164.06 - L520 164.07 - L520 20/1 6 7 20/1 20/1 5 7 1ID 1111 6 8 10 165.06 - L520 165.07 - L520 - INN - WM to •= mil KM K NZ Ell I� 2 6 9 164.08 - L520 IMMISIMI 20/1 20/1 8 io 20/1 165.08 - L520 11 164.11 - L520 20/1 11 - 20/1 .11111 167.08 - L520 12 165.10 - L520 1 1 166.10 - L520 TOTAL KW (GEN) © .9 P.F. 13 164.12 - L520 - 20/1 =um 167.09 - L520 14 165.11 - L520 - 20/1 12 MENNEEll 21/1 21/1 INFAI111101 21/1 11111MTIMIEEll 2./1 21/1 MIME° 2./1 2 1 INIETAMII /1 15 164.13 - L520 MI= - 20/1 20/1 15 17 IIfl 1111 16 18 165.12 - L520 165.13 - L520 - 20/1 17 164.14 - L520 166.12 - L520 19 165.01 - L520 - 20/1 20/1 19 1111 20 165.14 - L520 20/1 20/1 21 165.02 - L520 166.13 - L520 20/1 21 011 22 166.03 - L520 18 ____ - 23 165.03 - L520 MEM= - - 20/1 20/1 20/1 20/1 VIII, 25 27 29 Ilmum 1111 24 26 166.04 - L520 SPARE SPARE SPARE - - IIIII - - 25 SPARE 27 SPARE Ifl 1111 28 3o 32 29 SPARE 31 SPARE MINE 20/1 SPARE - IIIII - _ _ Eggf®I 4 - 33 SPARE 20/1 22 20/1 33 IIn 34 SPARE 35 SPARE - 20/1 EN1111 - 36 SPARE - KM 37 39 SPARE SPARE OEIIIIIIII. MEI 20/1 37 11111 38 SPARE U10 2 20/1 39 III' 40 SPARE�IM/1 28 167.17 - L520 111111111FOINE 41 PDU 164 LANTRONIX 20/1 20/1 20/1 41 SPARE 42 SPARE - 20/1 PDU 166.01 PANEL "166 01 /2" SCHEDULE FED FROM UPS 1A UPP1 SERVICE: 120/208V., 30, 4W. CONDUCTOR COLOR CODE LOAD M. L. O. BUS RATING A. MINIMUM CIRCUIT BREAKER LEG 1 - BLACK 10 KVA INTERRUPTING CAPACITY LEG 2 - RED 10 KVA SEPARATE GROUNDING 10,000 A. LEG 3 - BLUE 10 KVA BAR 35% GROUND -GREEN GROUNDED PANEL MAY BE TOP OR NEUTRAL - WHITE BOTTOM FEED AT CONTRACTORS OPTION MAIN BREAKER OR MAIN BREAKER RATING 225A. MAIN LUGS ONLY AS INDICATED POLE NO SERVES LOAD BREAKER POLE NO 12 3 POLE SERVES LOAD 1 BREAKER POLE NO 2 LEG AMPS BPPB1 LEG 1 AMPS 1 2 3 POLES NO 1 2 3 POLES 20/1 1 166.05 - L520 CRPPB1 20/1 416.24 2 167.04 - L520 - 6 3 166.06 - L520 - 20/1 207.84 4 167.05 - L520 - 20/1 4 5 166.07 - L520 112.63 - 20/1 CHILLER #1 6 167.06 - L520 298.8 - 20/1 6 7 166.08 - L520 - CHILLER #3 20/1 298.8 8 167.07 - L520 - 96 20/1 20/1 8 io 9 166.09 - L520 - 20/1 11 29 1754.63 10 167.08 - L520 - 1 1 166.10 - L520 TOTAL KW (GEN) © .9 P.F. 2930 - 20/1 12 167.09 - L520 - 20/1 12 13 166.11 - L520 - 20/1 14 167.10 - L520 - 20/1 14 15 166.12 - L520 - 20/1 18 167.11 - L520 20/1 20/1 16 18 17 166.13 - L520 - 20/1 18 167.12 - L520 19 167.01 - L520 - 20/1 20 167.13 - L520 20/1 20 21 167.02 - L520 - 20 /1 22 167.14 - L520 - 20/1 22 23 167.03 - L520 - 20/1 24 26 167.15 - L520 167.16 - L520 - - 20/1 20/1 24 26 25 SPARE - 20/1 27 SPARE - 20/1 28 167.17 - L520 - 20/1 20/1 28 30 29 SPARE - 20/1 30 SPARE 31 SPARE - 20/1 32 SPARE - 20/1 32 33 SPARE - 20/1 • 34 SPARE - 20/1 34 35 SPARE - 20/1 36 SPARE - 20/1 36 37 SPARE 20/1 38 SPARE - 20/1 38 39 SPARE - 20/1 40 SPARE 20/1 40 41 SPARE - 20/1 42 SPARE - 20/1 42 LOAD SUMMARY CALCULATIONS PANEL/DEVICE LIGHTING LOAD RECEPTACLE LOAD MOTOR LOAD CONTINUOUS LOAD NON CONTINUOUS LOAD BPPA1 136.1 BPPA2 136.1 BPPB1 136.1 BPPB2 136.1 CRPPA1 416.24 CRPPB1 416.24 DSA1 6 233.8 46.1 DSB1 15 207.84 MCCA 69.08 MCCB 112.63 CHILLER #1 298.8 CHILLER #2 298.8 CHILLER #3 298.8 UPS #1 11 8 96 4 UPS #2B 172.8 TOTAL 11 29 1754.63 1456.2 . 4 TOTAL KVA @ 480V, 3 ¢ 3254.83 TOTAL KW (GEN) © .9 P.F. 2930 GENERAL NOTES: 1. PANEL SCHEDULES INDICATED ON THESE DRAWINIGS ARE PROVIDED WITH PDU BY PDU MANUFACTURER WITHOUT THE SPECIFIED BRANCH BREAKERS. CONTRACTOR SHALL PROVI ' E ALL BRANCH BREAKERS INDICATED HEREIN. 2. FOR EACH L520 CIRCUIT INDICATED, CONTRACTOR SHALL PROVIDE 2- #10'S, 1410 GND. IN 3/4' "SEAL -TITE" FLEXIBLE CONDUIT FROM PDU TO OUTLET MOUNTED BENEATH THE DESIGNATE OUTLET SHALL BE NEMA L5 -20R RECEPTACLE MOUNTED IN OUTLET BOX. DO NOT ANCHOR B CONCRETE FLOOR. 3. FOR EACH L630 CIRCUIT INDICATED, CONTRACTOR SHALL PROVIDE 2- #10'S, 1- #10 GND. IN 3/ "SEAL -TITE" FLEXIBLE CONDUIT FROM PDU TO OUTLET MOUNTED BENEATH THE DESIGNATE OUTLET SHALL BE NEMA L6 -30R RECEPTACLE MOUNTED IN OUTLET BOX. DO NOT ANCHOR B CONCRETE FLOOR. 4. FOR EACH CIRCUIT, PROVIDE LABELS TO IDENTIFY. RACK NUMBER AND CIRCUIT NUMBER AT ENDS OF CIRCUIT CONDUIT. ALSO, PROVIDE LABEL ON OUTLET COVERPLATE TO IDENTIFY CI NUMBER AND PDU PANEL. 0 RACK. X TO RACK. X TO I OTH CUIT ELOc1O(o( REVIEWED FOR CODE COMPLIANCE NFPF A70 -NEC kid 11 LUu I i►arUta B !tDY. .�ivr I N RECEIVED CITY OF TUKWILA FEB 0 5 ZUUY PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM 2 3 4 Date: 12-12 -08 Revision 01 -0509 01 -15 -09 01 -26 -09 02 -02 -09 Sheet No. co c e N 2 Q CD ' WI I 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 E-16 ELECTRICAL PANEL SCHEDULES HAND RUB EXPOSED CONCRETE 6" NO SCALE CONNECT FLOOR STAND TO EXISTING RAISED FLOOR GROUND GRID USING H -TAP CRIMP CONNECTOR -� #6 BARE COPPER GROUND, REFER TO GROUNDING PLAN 3/4" CHAMFER v � g o r _, 4 ..,. r o__ - T _ -. . . FLOOR JAB L L +12" MBP #4 BARS @ 6" O.C., BOTH WAYS TOP AND BOTTOM J NO SCALE GENERAL NOTES: 1. ALL ANCHORING BOLTS SHALL BE EMBEDDED A MINIMUM OF 2" DEEP IN THE CONCRETE SLAB. REFER TO DETAIL 8B. VENTILATING AIR OPENING, DO NOT BLOCK r • 0y OUTLINE OF EQUIPMENT (W X L) 0 CHIP TO EXPOSED AGGREGATE CONCRETE EQUIPMENT BASE DETAILS 6.25" L - 39.25° 26.75" f NEW UPS 2B 500 KVA 0.9 PF �a (I) _o UPS ANCHORING LAYOUT 0 w \ o NOTES INDICATED BY NUMBER IN Q : 1. REFER TO DETAIL 8C, THIS SHEET FOR UPS FRAMING ANCHORING. I I� FRONT OF SIDE CAR ATTACHED TO PDU MAIN CABINET PDU MOUNTING DETAIL NO SCALE FRONT OF PEN MAIN CABIN SECURE PDU MAIN C TO FLOOR STAND US HARDWARE PROVID MANUFACTU ER SECURE FLOOR :NAND TO CONCRETE F- OOR USING 1/4" DIA. A CHOR BOLTS (4 PER LEA.) NOTES: 1. L IS THE OVERALL LENGTH OF THE 9. FLOOR - SUPPORTED EQUIPMENT F SPECIFIC DETAIL IS PROVIDED. CC PADS SHALL BE LIGHTWEIGHT 10. CONCRETE WITH A MINIMUM OF 5. CEMENT PER CUBIC YARD. WATEF RATIO SHALL NOT EXCEED 8 GALL' WATER PER SACK. 2. REFER TO DETAIL 8A, THIS SHEET FOR SEISMIC BRACKET ANCHORING FOR EPS7000. 3. SIDE PANEL ANCHORING REQUIRES ONLY ONE TYPE A BOLT (.531 0). ADJUST LEG TO PRO QE STAND HEIGH OF 24'110 MATCH EXISTING RAI D FLOOR NET G BY QUIP ENT. 2. W IS THE OVERALL WIDTH OF THE QUIPM T 3. CONCRETE SHALL BE NOT LESS TH N 3,000 PSI @28 DAYS. 4. HORIZONTAL SURFACES SHALL BE AMPS AND SCREEDED TO A TRUE SURFACE ( AKING ARE TO FILL ALL LOW SPOTS) AND STEEL TRO ` LED TO A HARD SLATE -LIKE SURFACE. " HE PA SHALL NOT BE MARKED OFF IN AREAS OR SCORED, BUT SHALL BE LEFT IN OF' E PLAI SURFACE. 5. ALL VERTICAL SURFACES SHALL HIVE A R FINISH. BBED 6. ALL EXPOSED EDGES SHALL BE CIT IAMFE D 1 ". 7. WHERE ONE EDGE OF PAD IS LOCAFED ADJACENT TO A WALL OR OTHER CONSTRUCTION, PROVIDE 1" THIC PRE M r LDED EXPANSION JOINT FILLER BETWEE THE "ND D AND THE ADJACENT CONSTRUCT! N AND IO NOT CHAMFER THE EDGE ADJACE T TO E EXPANSION JOINT FILLER. 8. ALL REINFORCING BARS SHALL BE COVER PAINT ALL WITH NOT LESS THAN 1 -1/2 INCHES OF VERTICAL SIDES CONCRETE. THIS DETAIL IS TYPICAL FOR OF PAD MISCELLANEOUS SAFETY YELLOW 3R WHI NCRET SACK! TO CE )NS OF 11. SLUMP OF CONCRETE SHALL NOT EXCEED '3. H NO FOR LE F NT NO S ALE UPS FRAME CONDUIT SUPPORT PDU FEEDER CIRCUIT FROM DISTRIBUTION PANEL. LABEL CONDUIT OR J -BOX WITH CIRCUIT IDENTIFICATION -� CONCRETE SLAB METALLIC CONDUIT (jU NEVV ECiUlPMEN RCiOVi NO SCALE ,41 w4, c 4 ‘11w 1 1 1 1 MS 1 11111 THRU WALL DETAIL CONDUIT PENETRATION DETAIL- OVERHEAD L BOLT TYPE "B" - .625"0 #6 BARE COPPER GROUND TO INDICATED RAISED FLOOR GROUND BAR .75 "(TYP. E.W.) SERVICE CND. 1 5" TWO -HOLE MECH. LUG °B.5* TERMINAL BLOCK @c© I o Do 16' PDU'S J 8A SE SMIC BRACKET ANCHORING DETAIL #6 BARE COPPER GROUND TO EXISTING RAISED FLOOR GROUND GRID 0.4375 HOLE (4 PLACES) OPENING FOR RAISED FLOOR FLOOR STAND 10' POWER CABLE ASSEMBLY BY PDI. 0 3/8' 0 GND. STUD ON INTERIOR PLATE. USE SUITABLE PRESSURE TERMINAL PER N.E.C. SECURE PLATE TO EXISTING CONCRETE FLOOR USING (4) 7/16" DIA. ANCHOR BOLTS TRANSIENT SUPPRESSION PLATE MOUNT INPUT J -BOX ON TRANSIENT SUPP. PLATE BOX AND TRANSIENT SUPPRESION PLATE DETAIL NO SCALE 6" MAX. INSIE1Ga N EV! E OL PM ENT1R000m. SEISMIC BRACKET FOR EPS 7000 FROM MGE d 1/2 - 13 GRADE 5 (2) BRACKET METALLIC CONDUIT PLASTIC ISOLATING L- CONDUIT SUPPORT COUPLING PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN WALL AND SLEEVE OUTSIDE SID1 NEW EQUIPMENT F;t 7C:7M PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN PIPE AND WALL EX. MECHANICAL PIPE MECHANICAL PIPE PENETRATION DETAIL - GROUNDING AI IMMEMINIM Pb t 0 NO SCALE NOTE: DETAIL APPLIES TO PRE - ACTION SPRINKLER PIPING. 1/2" DIAMETER HILTI HDI ANCHORS OF 2" MINIMUM EMBEDMENT --�_ UPS FRAME OR BRACKET ° -- BOLT ANCHORING DETAIL NO SCALE CONCRETE SLAB EXTEND CABLE AND TERMINATE AT PDU INPUT CIRCUIT BREAKER PIPE THRU WALL DETAIL Ill` II�L4 VV Ec u1PMENJ RO0M REFER TO DETAIL 7, THIS SHEET PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN PIPE AND WALL 1I11r //A t :U I sIDE 1'IEVV ECl(.Jll2iVlENrr Fto1:. M PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN CONDUIT _ WALL AND SLEEVE CONDUIT CLAMP MOUNTED TO FLOOR CONCRETE FLOOR RAISED FLOOR 4 4 PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN CONDUCTOR AND SLEEVE 1 1 1 THRU WALL AT FLOOR DETAIL CQNDUIT PENETRATION DETAILS -BELOW RAISED FLOOR NO SCALE PIPE GROUND CLAMP A.L.T. NO. 900 SERIES, CLASS II BOLT TYPE CONNECTOR WITH 2 -HOLE GROUND LUG, AS MANUFACTURED BY ADVANCED LIGHTNING TECHNOLOGIES, INC. - 17 -RAISED FLOOR 1i l i L)F IIE'/V E0 1IIPM'L°, " ROOM 6" MAX. III CONDUIT Q 47 UPS FRAME PLAN VIEW PIPE GROUND CLAMP BOLT TYPE "A " - .531W CONCRETE SLAB ELO9OEO CONDUIT CLAMP MOUNTED TO FLOOR CODE REVIEWED F©f CCMPLI4N, NVFPA 70 - NEC I-L 11 ZUud r -O SI ©N VERIFY SIZE OF PIPE ATJ " -'"^°� SITE PRIOR TO ORDERING THE GROUND CLAMP -�-- WHERE GROUND CLAMP IS INSTALLED, REMOVE PAINT OR PROTECTIVE COATING OF PIPE WITH WIRE BRUSH TO EXPOSE BARE METAL. APPLY THIN COAT OF ELECTRICAL JOINT COMPOUND, ALCOA NO. 2 CONNECT GROUND LEAD TO PIPE CLAMP BY UTILIZING 2 -HOLE LUG WITH COMPRESSION (CRIMP) CONNECTION EXTEND #6 GROUND CONDUCTOR TO BUILDING STEEL END VIEW NO SCALE NOTE: PROVIDE GROUND CLAMP ON PIPES NOT EQUIPPED WITH PLASTIC ISOLATION COUPLING, EXTENDING THROUGH NEW SECURE WALL. LOCATE GROUND CLAMP ON SECURE SIDE OF WALL. RECEIVED CITY OF TUKWILA FEB 0 5 7009 PERMIT CENTER UPS FRAME ANCHORING DETAIL NO SCALE WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 3 Expires \G MA oY WASii4t r.. 1 01 -05 -09 2 01 -15 -09 3 01 -26 -09 4 02 -02 -09 Lac • nJi)69 / ONAL 7 co c c 2 (I) k cK vzc ' OD Y � (I) qL) c: O FaC. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM DL Z Praj. Mgr.: KCM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 Project No. WTA. 08093 Sheet No. E -17 PERMIT SET ELECTRICAL DETAILS 1 a ° - q J . qq ° a q U ,, a ° , ° y q na ° Q ° U Q a 4v v 4 a v ° d q U.y 4_ C ° 4 V ° a 9.4 ° v L ", 4 ° aU ° ° ° q v - _ -° ° ° a . ° U 4 a v ® � _ l I ° 1 I . { I a HAND RUB EXPOSED CONCRETE 6" NO SCALE CONNECT FLOOR STAND TO EXISTING RAISED FLOOR GROUND GRID USING H -TAP CRIMP CONNECTOR -� #6 BARE COPPER GROUND, REFER TO GROUNDING PLAN 3/4" CHAMFER v � g o r _, 4 ..,. r o__ - T _ -. . . FLOOR JAB L L +12" MBP #4 BARS @ 6" O.C., BOTH WAYS TOP AND BOTTOM J NO SCALE GENERAL NOTES: 1. ALL ANCHORING BOLTS SHALL BE EMBEDDED A MINIMUM OF 2" DEEP IN THE CONCRETE SLAB. REFER TO DETAIL 8B. VENTILATING AIR OPENING, DO NOT BLOCK r • 0y OUTLINE OF EQUIPMENT (W X L) 0 CHIP TO EXPOSED AGGREGATE CONCRETE EQUIPMENT BASE DETAILS 6.25" L - 39.25° 26.75" f NEW UPS 2B 500 KVA 0.9 PF �a (I) _o UPS ANCHORING LAYOUT 0 w \ o NOTES INDICATED BY NUMBER IN Q : 1. REFER TO DETAIL 8C, THIS SHEET FOR UPS FRAMING ANCHORING. I I� FRONT OF SIDE CAR ATTACHED TO PDU MAIN CABINET PDU MOUNTING DETAIL NO SCALE FRONT OF PEN MAIN CABIN SECURE PDU MAIN C TO FLOOR STAND US HARDWARE PROVID MANUFACTU ER SECURE FLOOR :NAND TO CONCRETE F- OOR USING 1/4" DIA. A CHOR BOLTS (4 PER LEA.) NOTES: 1. L IS THE OVERALL LENGTH OF THE 9. FLOOR - SUPPORTED EQUIPMENT F SPECIFIC DETAIL IS PROVIDED. CC PADS SHALL BE LIGHTWEIGHT 10. CONCRETE WITH A MINIMUM OF 5. CEMENT PER CUBIC YARD. WATEF RATIO SHALL NOT EXCEED 8 GALL' WATER PER SACK. 2. REFER TO DETAIL 8A, THIS SHEET FOR SEISMIC BRACKET ANCHORING FOR EPS7000. 3. SIDE PANEL ANCHORING REQUIRES ONLY ONE TYPE A BOLT (.531 0). ADJUST LEG TO PRO QE STAND HEIGH OF 24'110 MATCH EXISTING RAI D FLOOR NET G BY QUIP ENT. 2. W IS THE OVERALL WIDTH OF THE QUIPM T 3. CONCRETE SHALL BE NOT LESS TH N 3,000 PSI @28 DAYS. 4. HORIZONTAL SURFACES SHALL BE AMPS AND SCREEDED TO A TRUE SURFACE ( AKING ARE TO FILL ALL LOW SPOTS) AND STEEL TRO ` LED TO A HARD SLATE -LIKE SURFACE. " HE PA SHALL NOT BE MARKED OFF IN AREAS OR SCORED, BUT SHALL BE LEFT IN OF' E PLAI SURFACE. 5. ALL VERTICAL SURFACES SHALL HIVE A R FINISH. BBED 6. ALL EXPOSED EDGES SHALL BE CIT IAMFE D 1 ". 7. WHERE ONE EDGE OF PAD IS LOCAFED ADJACENT TO A WALL OR OTHER CONSTRUCTION, PROVIDE 1" THIC PRE M r LDED EXPANSION JOINT FILLER BETWEE THE "ND D AND THE ADJACENT CONSTRUCT! N AND IO NOT CHAMFER THE EDGE ADJACE T TO E EXPANSION JOINT FILLER. 8. ALL REINFORCING BARS SHALL BE COVER PAINT ALL WITH NOT LESS THAN 1 -1/2 INCHES OF VERTICAL SIDES CONCRETE. THIS DETAIL IS TYPICAL FOR OF PAD MISCELLANEOUS SAFETY YELLOW 3R WHI NCRET SACK! TO CE )NS OF 11. SLUMP OF CONCRETE SHALL NOT EXCEED '3. H NO FOR LE F NT NO S ALE UPS FRAME CONDUIT SUPPORT PDU FEEDER CIRCUIT FROM DISTRIBUTION PANEL. LABEL CONDUIT OR J -BOX WITH CIRCUIT IDENTIFICATION -� CONCRETE SLAB METALLIC CONDUIT (jU NEVV ECiUlPMEN RCiOVi NO SCALE ,41 w4, c 4 ‘11w 1 1 1 1 MS 1 11111 THRU WALL DETAIL CONDUIT PENETRATION DETAIL- OVERHEAD L BOLT TYPE "B" - .625"0 #6 BARE COPPER GROUND TO INDICATED RAISED FLOOR GROUND BAR .75 "(TYP. E.W.) SERVICE CND. 1 5" TWO -HOLE MECH. LUG °B.5* TERMINAL BLOCK @c© I o Do 16' PDU'S J 8A SE SMIC BRACKET ANCHORING DETAIL #6 BARE COPPER GROUND TO EXISTING RAISED FLOOR GROUND GRID 0.4375 HOLE (4 PLACES) OPENING FOR RAISED FLOOR FLOOR STAND 10' POWER CABLE ASSEMBLY BY PDI. 0 3/8' 0 GND. STUD ON INTERIOR PLATE. USE SUITABLE PRESSURE TERMINAL PER N.E.C. SECURE PLATE TO EXISTING CONCRETE FLOOR USING (4) 7/16" DIA. ANCHOR BOLTS TRANSIENT SUPPRESSION PLATE MOUNT INPUT J -BOX ON TRANSIENT SUPP. PLATE BOX AND TRANSIENT SUPPRESION PLATE DETAIL NO SCALE 6" MAX. INSIE1Ga N EV! E OL PM ENT1R000m. SEISMIC BRACKET FOR EPS 7000 FROM MGE d 1/2 - 13 GRADE 5 (2) BRACKET METALLIC CONDUIT PLASTIC ISOLATING L- CONDUIT SUPPORT COUPLING PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN WALL AND SLEEVE OUTSIDE SID1 NEW EQUIPMENT F;t 7C:7M PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN PIPE AND WALL EX. MECHANICAL PIPE MECHANICAL PIPE PENETRATION DETAIL - GROUNDING AI IMMEMINIM Pb t 0 NO SCALE NOTE: DETAIL APPLIES TO PRE - ACTION SPRINKLER PIPING. 1/2" DIAMETER HILTI HDI ANCHORS OF 2" MINIMUM EMBEDMENT --�_ UPS FRAME OR BRACKET ° -- BOLT ANCHORING DETAIL NO SCALE CONCRETE SLAB EXTEND CABLE AND TERMINATE AT PDU INPUT CIRCUIT BREAKER PIPE THRU WALL DETAIL Ill` II�L4 VV Ec u1PMENJ RO0M REFER TO DETAIL 7, THIS SHEET PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN PIPE AND WALL 1I11r //A t :U I sIDE 1'IEVV ECl(.Jll2iVlENrr Fto1:. M PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN CONDUIT _ WALL AND SLEEVE CONDUIT CLAMP MOUNTED TO FLOOR CONCRETE FLOOR RAISED FLOOR 4 4 PROVIDE FIRE RETARDING FOAM IN SPACE BETWEEN CONDUCTOR AND SLEEVE 1 1 1 THRU WALL AT FLOOR DETAIL CQNDUIT PENETRATION DETAILS -BELOW RAISED FLOOR NO SCALE PIPE GROUND CLAMP A.L.T. NO. 900 SERIES, CLASS II BOLT TYPE CONNECTOR WITH 2 -HOLE GROUND LUG, AS MANUFACTURED BY ADVANCED LIGHTNING TECHNOLOGIES, INC. - 17 -RAISED FLOOR 1i l i L)F IIE'/V E0 1IIPM'L°, " ROOM 6" MAX. III CONDUIT Q 47 UPS FRAME PLAN VIEW PIPE GROUND CLAMP BOLT TYPE "A " - .531W CONCRETE SLAB ELO9OEO CONDUIT CLAMP MOUNTED TO FLOOR CODE REVIEWED F©f CCMPLI4N, NVFPA 70 - NEC I-L 11 ZUud r -O SI ©N VERIFY SIZE OF PIPE ATJ " -'"^°� SITE PRIOR TO ORDERING THE GROUND CLAMP -�-- WHERE GROUND CLAMP IS INSTALLED, REMOVE PAINT OR PROTECTIVE COATING OF PIPE WITH WIRE BRUSH TO EXPOSE BARE METAL. APPLY THIN COAT OF ELECTRICAL JOINT COMPOUND, ALCOA NO. 2 CONNECT GROUND LEAD TO PIPE CLAMP BY UTILIZING 2 -HOLE LUG WITH COMPRESSION (CRIMP) CONNECTION EXTEND #6 GROUND CONDUCTOR TO BUILDING STEEL END VIEW NO SCALE NOTE: PROVIDE GROUND CLAMP ON PIPES NOT EQUIPPED WITH PLASTIC ISOLATION COUPLING, EXTENDING THROUGH NEW SECURE WALL. LOCATE GROUND CLAMP ON SECURE SIDE OF WALL. RECEIVED CITY OF TUKWILA FEB 0 5 7009 PERMIT CENTER UPS FRAME ANCHORING DETAIL NO SCALE WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 3 Expires \G MA oY WASii4t r.. 1 01 -05 -09 2 01 -15 -09 3 01 -26 -09 4 02 -02 -09 Lac • nJi)69 / ONAL 7 co c c 2 (I) k cK vzc ' OD Y � (I) qL) c: O FaC. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM DL Z Praj. Mgr.: KCM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 Project No. WTA. 08093 Sheet No. E -17 PERMIT SET ELECTRICAL DETAILS l�v TYP. 11,11211 E C TE T F B= 1 ..._.... - - -_ E [AIR (TYP. 144.04 14 ,04 4 14 204 14 205 14206 144.03 14405 144.00 144.0 143 LC 140.89 1432/ 142 08 14209 144.09 141.10 144,11 4.12 144,13 143.09 143.10 3 11 '443.12 143.13 15 14418 44.17 144 18 - E211 1 C'.fiUlt MEN TO MSGB- XI TING 14213 14214 142.15 W48'.' 142.17 by / w / .+.ti Mil ..__. 0 2 __..__ 2'___222 � IlUIII �I,Rl$ , _ _2222 144,45 144.14 144, - t ®,, 143.fk2 742.14 145,19 113.14 143.17 143,12 15a KV .. 1111111111111111111111 inesainuinasi y5_ 14 14211 4-12 16'!.51 1o1.52 157.(42 15144 114!x5 10 , 167.07 117,5,9 IBT.05 5'7.10 - 187.11 14'!.12 167.14 187.11 22 _2 __. _. _- 2222_... _. .' � � 102,53 190.CW 155 4 105.05 125.07 100,00 199.09 100.10 109.71 18(1.13 V � 2,222 � '_a --.�. A .. .�.�... - . �.. •_�. ' 155.01 185.02 15528. 1E5.04 _165J36 _155. - _1E5,OZ. 14 .�- - 105.09... 55_10 _155_11- .108.12. ✓5_l1. _168.14 1 ........ ... ... 1_.... 1111111 19412 44.11 '•.14 fi9KVA .._.. ...... .._. 1111 2222 __ 1 11_..111111. 157.10 NEW Pf K 150 VA 01 -05 -09 2 01 -15 -09 3 01-26-09 Revision Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Pro'. Mgr.: KCM Date: 12- 12 -O8 95% REVIEW 100% CD ADD. NO. 1 A GENERAL NOTES: i VE' 1 1 N REFER TO FIRE PROTECTION SHEETS FP -1 AND FP -2 FOR LOCATION OF FIRE SPRINKLER PIPING PENETRATIONS. WHERE PIPE PENETRATES NEW SECURED WALL, INSTALL #6 GROUND TO PIPE FROM BUILDING STEEL. 2. REFER TO FIRE PROTECTION SHEETS FP -1 AND FP -2 FOR LOCATION OF VESDA PIPING PENETRATIONS. WHERE PIPE PENETRATES NEW SECURED WALL, INSTALL #6 GROUND TO PIPE FROM BUILDING STEEL. EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF H IS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. AE4'SII1l VNµlEE ,II NOTES 1 t ALL POin INS PERI 2, SI- W: SCALE: 1/8" = 1' -0" EXI ING 2/0 BARE STRANDED COPPER INTERIOR GROUNDING CON UCTOR BELOW RAISED FLOOR ON CONCRETE, SHALL BE RE- OUTED TO POINT INDICATED, PRO IDE CONDUIT SLEEVE 1MTH PLASTIC ISOLATION COUPLER AT WAL I PENETRATION. RE -L CATE EXISTING RFGB AND ALL GROUND CONDUCTORS TO OUTIDE NEW EQUIPMENT ROOM AS INDICATED AND PROVIDE SIGN ABCYE FLOOR AND OVERHEAD TO IDENTIFY LOCATION OF THIS GRO ND BAR. SIGN SHALL READ "RAISED FLOOR GND. BAR -1 BELOW'. FIRE I5 P11I2Jl L.EF2 1400E1 DICATED BY NUMBER IN 0 : :. ONDUCTORS INDICATED WITH HATCHING SHALL BE REMOVED TO T INDICATED. EXI TING #4 BARE INTERIOR GROUNDING CONDUCTORS BELOW RAISED FLC R ON CONCRETE, SHALL REMAIN. ALL 2/0 BARE INTERIOR GROUNDING CONDUCTOR TO 2/0 BARE METER GROUND RING WITH H -TAP CONNECTION. REFER TO DETAIL EET E -20. EXISTING 2/0 BARE PERIMETER GROUNDING CONDUCTOR BELOW RAIS D FLOOR ON CONCRETE, SHALL REMAIN. INST LL 2/0 BARE PERIMETER GROUNDING CONDUCTOR BELOW RAISED FLO R ON CONCRETE. CONNECT NEW CONDUCTOR TO EXISTING 2/0 BAR PERIMETER GROUNDING. REFER TO DETAIL 2, SHEET E -20. I1Aril1' FIRST FLOOR PLAN - ELECTRICAL GROUNDING 9. INSTALL NEW 48" RAISED FLOOR GROUND BAR FOR NEW EQUIPMENT ROOM. PROVIDE SIGN ABOVE FLOOR AND OVERHEAD TO IDENTIFY LOCATION OF THIS GROUND BAR. SIGN SHALL READ "RAISED FLOOR GND. BAR -2 BELOW'. 10. INSTALL NEW AREA GROUND BAR AT LOCATION INDICATED (9' -6" A.F.F.). PROVIDE SIGN ABOVE FLOOR AND OVERHEAD TO IDENTIFY LOCATION OF THIS GROUND BAR. SIGN SHALL READ "AREA FLOOR GND. BAR -2 BELOW'. 11. INSTALL #750 MCM INSULATED GROUND EQUALIZER CONDUCTOR FROM NEW RFGB -2 TO RE- LOCATED RFGB -1. 12, INSTALL #750 MCM INSULATED GROUND EQUALIZER CONDUCTOR FROM RE- LOCATED RFGB -1 TO EXISTING MSGB LOCATED IN ELECTRICAL ROOM. 13. WHERE CHILLED WATER PIPS PENETRATE WALL, INSTALL #6 GROUNDING CONDUCTOR FROM EXISTING CHILLED WATER SUPPLY AND RETURN PIPES TO BUILIDING STEEL. SEE DETAIL 6, SHEET E -20. 14. I W ALL #750 MCM INSULATED GROUND EQUALIZER CONDUCTOR FROM RFGB-2 TO EXISTING M$GB IN ELECTRICAL ROOM, REFER TO KEYED NOTE 7 WHEN PENETRATE NEW WALL. 15. TRANSIENT SUPPRESSION PLATE GROUND -BOND PLATE TO EXISTING RAISED FLOOR GROUND GRID USING #6 BARE COPPER. PROVIDE H -TAP CRIMP CONNECTOR AT GROUND GRID. USE 2 -HOLE COMPRESSION LUG AT PLATE, CORI4I : 16. PDU FLOOR STAND GROUND -BOND STAND TO EXISTING RAISED FLOOR GROUND GRID USING NO. 6 BARE COPPER. PROVIDE H -TAP CRIMP CONNECTOR AT GROUND GRID. USE 2 -HOLE COMPRESSION LUG AT STAND. 17. TRANSIENT SUPPRESSION PLATE GROUND -BOND PLATE TO NEW RFGB -2 USING #6 BARE COPPER. PROVIDE 2 -HOLE COMPRESSION LUG AT BOTH ENDS. 18. PDU'S ISOLATION TRANSFORMER GROUND -BOND ISOLATION TRANSFORMER SECONDARY GROUND TO NEW RFGB -2 USING NO. 1/0 INSULATED CONDUCTOR. 19. CRAC UNIT FLOOR STAND GROUND-BOND CRAC UNIT METAL FLOOR STAND TO EXISTING RAISED FLOOR GROUND GRID USING NO. 4 BARE COPPER. PROVIDE 2 -HOLE COMPRESSION LUG CONNECTION AT FLOOR STAND. PROVIDE H -TAP CRIMP CONNECTOR AT EXISTING GROUND GRID. 20. CONNECT BOTH NEW 2/0 PERIMETER GROUND AND EXISTING #4 GROUND GRID TO RAISED FLOOR PEDESTAL. TERMINATE EXISTING #4 CONDUCTOR BY ATTACHING TO MAIN CONTINUOUS STRINGER OF RAISED FLOOR SYSTEM WITH BOLT, LOCK WASHER AND NUT, DRILLED AND INSERTED THROUGH SIDE OF STRINGER. REFER TO DETAIL 1, SHEET E -20, ELO9oio I 1 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC r GG 1 1 LuuJ _® atyofTukwila LNNG DIVI$L RECEIVED CITY OF TUKWJLA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 02-02-09 E -18 u n L , 141 W in IT 5 ID IA w N n� W IZ ISO Id 11 " w �Wo Z � > to w dL1 PERMIT SET Project No. WTA, 08093 Sheet No. FIRST FLOOR PLAN - ELECTRICAL, GROUNDING EG 6 AWG TYPICAL XFMR UTRR1 -3 #4/0 AWG BARE TO GROUND RING 0 O 0 0 0 0 0 O 0 ♦ 4 T 4 O 0 i o UPS BATTERIES XFMR UTRL1 -1 XFMR TRLA1 a PRODUCERS TRRB1 XFMR A UTRR1 -2 )(FMR TO COLD WATER PIPE, OR BUILDING STEEL AS REQUIRED BY LOCAL AUTHORITIES (TYPICAL) XFMR TRRRA1 A l 0 0 0 0 0 0 0 • 0 RFGB -1) U GENERAL NOTES: 1. PROVIDE FROUN I.D. TAGS ON EVERY GROUND LEADS. CH TA SHALL IDENTIFY TERMINATION AT OPPOSIT ° END ( " IGIN). REFER TO DETAIL 8, E -20. 0 0 NO SPF SYS 0 0 0 O 4 A (TYPI UNDE FLOOR, 2/0 AWG PERI ETER SCALE INKLER PIPE EM GROUND EXISTING MSGB O 0 0 O 0 1 DOMESTIC WATER SYSTEM GROUND 0 0 RELOCATED / RFGB -1 (UNDERFLOOR) J r GROUNDING SCHEMATIC ABSORBERS 0 0 0 0 0 • t 0 t t \J r n�l 0 0 1 I I 1 1 Al i 1 I 1 1/1 I I 1 1 I \ BURIED GROUNDING SYSTEM GROUND ROD C7 EXOTHERMIC 1 7 CONNECTION Imo\ BUILDING STEEL 2/0 AWG L rt RFGB -2 0 Ln L HATCH CONDUCTORS SHALL BE REMOVED BY DC CONTRACTOR. REFER TO DC FLOOR PLANS. - 2/0 AWG, MOUNTED UNDER CABLE LADDER (TYPICAL) EXIST. AGB -1 • 0 . 0 0 0 t " 0 0 0 0 0 0 0 0 0 ab 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 NON - ISOLATED MAIN AC DISCONNECT "-GROUND BUS IN MDS 4/0 AWG TO CABLE --'TRAY AT (4) LOCATIONS NEW UNDERFLOOR 2/0 AWG. REFER TO E -11. NEW UNDERFLOOR 2/0, REFER TO E -11. SUPPLEMENTAL EQUIPMENT GROUNDING SYSTEM GROUND TAG, TYPICAL. REFER TO DETAIL ON E -20. ----�` 0 NEW UNDERFLOOR 2/0 AWG. REFER TO E -11. NEW UNDERFLOOR 2/0 AWG PERIMETER. REFER TO E --11.- NEW UNDERFLOOR 2/0 AWG, REFER TO E -11. - -NEW UNDERFLOOR 2/0 PERIMETER. REFER TO E -11. LGB -2 4 AWG (TYPICAL)— NEW #750MCM. ---..,,\ REFER TO E -11. 4 h 500 KCMIL ISOLATED — MOUNTED UNDER CABLE LADDER ALONG EACH EQUIPMENT LINEUP 0 0 I) ti 6 AWG TO EQUIPMENT RACKS BATTERY ROOM MOUNTED UNDER CABLE LADDER ti r\J r J r4.J f NEW R F G B-2 CBEN 111 41t... (NEW SECURED ROOM UNDERFLOOR) V.r pr COMPRESSIONED TWO HOLE LUG a 0 z 0 u. X a O NEW 2/0 CONDUCTORS SHALL BE INSTALLED BY DC CONTRACTOR (TYPICAL FOR 19). REFER TO DC FLOOR PLANS. 0 r-, MPB CABLE LADDER a 1- NEW 2/0 CONDUCTOR SHALL BE INSTALLED BY DC CONTRACTOR. REFER TO DC FLOOR PLANS. NEW 750MCM 6 AWG TYPICAL RECTIFIERS 1 1_] 1_ DCGB -1 a 0 a 1- a co 0 z NEW 6 AWG CONDUCTOR TO NEW PDF 144.10. SHALL BE INSTALLED BY DC CONTRACTOR. REFER TO DC FLOOR PLANS. 600 KCMIL d 0 0 0 0 O 0 0 BATTERY RACKS 0 a 0 TO CABLE TRAY AT (4) LOCATIONS 0 0 0 BY OTHERS NEW il6 CONDUCTOR SHALL BE INSTALLED BY DC CONTRACTOR, REFER TO DC FLOOR PLANS, UNDERFLOOR 2/0 AWG PERIMETER REFER TO E -11 FOR PDU AND TSP LOCATIONS. 0 0 0 NEW AG B -2 0 • • NEW BATTERY RACKS 0 0 O 0 O 0 0 0 0 MOUNTED UNDER CABLE LADDER FOR VLB LOCAL SWITCH NEW 6AWG CONDUCTOR TO NEW PDF 167.09. SHALL BE INSTALLED BY DC CONTRACTOR. REFER TO DC FLOOR PLANS. 0 0 0 UPS GROUND. NEW 1 -3/0 GND. IN 2 "C. (PVC) 0 0 0 CABLE LADDER LOCAL SWITCH GROUND BARS 000B -2 0 ICB 750 MCM 750 MCM FEE LRE l 750 MCM ELOO(O I CABLE LADDER FRAME AISLE GROUND EXISTING CABLE LADDER FRAM MAIN GROUND BUS. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC Fhb 11 lUij i CityOfTukwila BUILDING DIVISION BATTERY RACKS 6AWG T YPICAL "--- RECTIFIERS ---- -- BY OTHERS C P RECEIVED CITY OF TUKWIIA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 NFU G .0"7`0 f s 00 CD tc CO d c) Fac. Code:TYKWWA Drawn By: IM, PS, ZJ 11111111111MIIIIIMMIONIIIIMMUUMENI Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -1 2 -08 Revision 01 -05 -09 01-15-09 01 -26 -09 02 -02 -09 E -19 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA, 08093 Sheet No. GROUNDING SCHEMATIC • TOTAL DEPTH OF SUPPORT SHALL NOT EXCEED 4' • #4 AWG. SUPP. BONDING CONDUCTOR #210 AWG. GROUND RING 0 1/4" THRU -BOLT CONNECTION. MAIN STRINGER. 600 VOLT ISOLATOR BUSHING UNISTRUT P3347 "U" SHAPED FITTING PAINT CONDUIT & SUPPORTS T MATCH ADJACE SUPPORT TO WALL W /3/8" TOGGLE BOLTS AT 18' O.C. MIN. DETAIL NOT TO SCALE 3/8" TOGGLE BOLTS FOR HOLLOW CMU WALL OR BOLTS IN EXPANSION SHIELDS FOR CONCRETE WALL 5/8 " -11 HEX HEAD CAP SCREWS CAD PLATED WITH CAD PLATED LOCKWASHER AND HEX HEAD NUT TERMINATE CONDUIT 6" FROM GROUND BAR. 5/8"0 STANDARD DETAIL 7G052 NO SCALE ` - LOCKWASHER AND NUT. J 0 0 0 7/18 "0 1/4 "x4" COPPER BUS O • NT STRUCTURE 4 010 10 UNISTRUT RAISED FLOOR PEDESTAL. ALL PAINT SHALL BE COMPLETELY REMOVED FROM OUTSIDE SURFACE PEDESTAL AT THE POINT WHERE CONNECTOR AND CONDUCTORS ARE ATTACHED TO THE PEDESTAL, TO PROVIDE MAXIMUM BONDING. #2/0 AWG. GROUND RING AWG. SUPP. BONDING CONDUCTOR. BURNDY U -BOLT (CAT. # GP64526G1). 1 /4"x4" COPPER BUS NOTE: 1. PROVIDE GROUND BAR MANUFACTURED BY NEWTON, RELTEC OR SAUNDERS. 2. LABEL BUS BARS AS INDICATED ON FLOOR PLAN. GROUND BAR DETAI NO SCALE GROUNDING CONDUCTOR NONMETALLIC BUSHING PVC MALE ADAPTER EQUAL TO CARLOW 943 UNISTRUT SUPPORT SCHEDULE 40 PVC CONDUIT AS SPECIFIED CARLON E978 NONMETALLIC, CONDUIT STRAPS OR APPROVED EQUAL PVC CONDUIT TERMINATION AT GROUND BAR C R• PH 4 1 t 2 01 -15 -09 3 01 -26 -09 4 02 -02 -09 Ir � 7/8" NEW BONDING JUMPER AS INDICATED. DETAIL NOT TO SCALE - 21/32" STAND -OFF BRACKET RNERS SHALL BE NDED ON ALL = NOLIC I.D. TAGS ENGRAVE CONDUCTOR ORIGIN ON TAG ,) ■- EXISTING RAISED FLOOR GROUND GRID BURNDY H -TAP COMPRESSION CONNECTOR OR APPROVED EQUAL. (2' (TYP.) ENTIRE SURFACE OF BUS SHALL BE FREE OF BURRS, ETC. CONTACT SURFACES OF BUS SHALL BE SANDED OR WIRE BRUSHED CLEAN. APPLY A THIN COAT OF NO -OX -ID (OR EQUIV.) ONLY WHERE LUGS ARE TO BE CONNECTED.- - 3/4" (--- ) 0 O Q CO :1V 0 0 Q. ---7/16 . " . (TYPICAL2F42) 5/8 " -11 HEX HEAD CAP SCREWS CAD PLATED WITH CAD PLATED LOCKWASHER AND HEX HEAD NUT SECURE TAG TO GROUNDING CONDUCTOR WITH TY -RAPS, NON- METALLIC CABLE, ETC. 3" 316 GROUND LOOP L.1 DO N DISCONNECT LEAD RAISED FLOOR PEDESTAL, ALL PAINT SHALL BE COMPLETELY REMOVED FROM OUTSIDE SURFACE PEDESTAL AT THE POINT WHERE CONNECTOR AND CONDUCTORS ARE ATTACHED TO THE PEDESTAL, TO PROVIDE MAXIMUM BONDING. - CORNERS SHALL BE ROUNDED ON ALL PHENOLIC I.Q. TAGS 1/4" HOLE PHENOLIC I.D. TAG ENGRAVE CONDUCTOR ORIGIN ON TAG I.D. TAG NOTE: 1. PHENOLIC TAGS SHALL BE BLACK WITH WHITE LETTERS. I.D. TAG DETAILS STANDARD DETAIL 7G101 NO SCALE #4 AWG. DETAIL NOT TO SCALE COMPUTER FLR. e GROUND RING L.14B DO N T DISCONNECT LEAD PHENOLIC I.D. TAG 1/4" HOLE #4 AWG. LOCKWASHER AND NUT. BURNDY U -BOLT OUTSIDE NEW EQUIPMENT ROOM EXISTING 6" CHWS PIPE EXISTING 6" CHWR PIPE NO SCALE NOTE: THIS DETAIL APPLIES TO BOTH CHS AND CHR PIPES EXITING SPACE AT NORTH AND WEST WALLS. SECURE TAG TO GROUNDING CONDUCTOR WITH TY -RAPS, NON- METALLIC CABLE, ETC. BRASS OR COPPER NUTS, LOCK WASHERS, FLAT WASHERS AND BOLTS GROUND BAR INSPECTION CUTOUT PROVIDE CLEAR HEAT - SHRINK OVER ENTIRE BARREL WITH MINIMUM 1 INCH OF CABLE INSULATION COVERED - NEW SECURE WALL STANDARD DETAIL 7G102 NO SCALE GROUNDING CONDUCTOR TERMINATION DETAIL NOTE: SINGLE HOLE FOR CHILLED WATER PIPE CONNECTIONS SIMILAR. 4 0 a it Mal INSIDE NEW EQUIPMENT ROOM EXTEND GROUNDING CONDUCTOR IN 3/4" CONDUIT TO BUILDING STEEL. EXOTHERMICALLY WELD TO BLDG. STEEL. EX. RAISED FLOOR CONNECT NEW #6 GROUNDING CONDUCTOR TO EXISTING PIPE, SEE GROUND CONDUCTOR TERMINATION DETAIL 4, THIS SHEET. CLEAN SURFACE WITH CLEANING PAD. APPLY A THIN COAT OF NO -OX -ID AT THE CONNECTING SURFACE. ALL LUGS SHALL HAVE A THIN COAT OF NO -OX -ID APPLIED TO THE STRIPPED CABLE END AND /OR INSIDE OF LUG BARREL BEFORE CABLE IS CRIMPED. TWO HOLE CONCENTRIC COMPRESSION TYPE COPPER, LONG BARREL LUG (BURNDY "YA" SERIES OR EQUAL BY "T & B ") WITH COPPER OR BRASS BOLTS AND LOCKWASHERS. PROVIDE 2 "X3" PHENOLIC I.D. TAG FOR EACH CONDUCTOR. CRIMP TOOL SHALL BE HYDRAULIC TYPE, WITH FULL CIRCUMFERENCE DIE CRIMPING TOOL FOR PROPER SIZE AND TYPE WIRE. LUGS SHALL HAVE THE NUMBER OF CRIMPS INSTALLED PER MANUFACTURER'S RECOMMENDATION. EX. PIPE r' FLANGE r rE XISTING CONCRETE FLOOR EX. 6" PIPE BELOW RAISED FLOOR PIPE GROUNDING DETAIL ELooio 1 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC E-Ld 11 2uid CityOf Tukwila BUILDING DIVISION . RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 1 9 • J /ONAL 4r Expire, 1 0Q� r� W04, I- w St" to N -MN am V t r■QW 4 w w �Wa Z� rziw: z ODpi n4. co •?3 C e; , zzzi co (.0 °1) (go (t) cf) Fac. Code :TYKWWA Drawn By: IM, PS, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision Designed By: KCM, DL, ZJ 01 -05 -09 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 Sheet No E -20 GROUNDING DETAILS MATCHLINE QU PMEN f FLOOR nr 1r - Ir II • I • 0 [IIL 0 T `1 II II I II II I JLJL II II I II II I r 1 11 1 I 1 1 I _1_ L. Ii1!1 � i iii •. 1111 1111 11111 111 ni � 1 11 11 11111111M1111111 IIII 1 Eml e mu r 1 ■ 0 .1 imm 11 1 11 ii v ;L t J 4 1 III 1 I I 11 II II I I II I II II I 1 11 I 2 1 11 1 11 0 2 0 TYP. TYP Y �Y • • ' X 1 6L(9 110 -7) . " 'I.i (6..' '1 14212_, 2. CABLE LADDER SIZE REPRESENTED IN FEET AND INCHES. 1 -OL INDICATES 12" WIDE CABLE LADDER. EX. 1- 6L(9 -1, 10 -7) GENERAL NOTES: 1. EXISTING CONDITIONSNOTE: EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER 3. CABLE LADDER INSTALLATION HEIGHT REPRESENTED IN FEET AND 1 11 INCHES. (10 -0) REPRESENTS 10 -0 ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE CABLE LADDER. EXISTING EQUIPMENT ROOM HAS RAISED FLOOR AT 2' -3" HIGH. 4. ALL CABLE LADDER TO BE SOLID BAR, 2" STRINGER, PAINTED GRAY. REFER TO DC -2 FOR CONTINUATION Aitt 11 I i idea: 1 1 1 � L 1 14 :b ,Ln..l.iit i-llu4L titr.l, 4, 04.44,41, aS..,ar"- 441.41, 441.41, 12.4 7 14402 144.03 144.04 144.05 144.06 144.07 144.08 144.09 144.10 144.11 EX. 1 -6 L 9 -1, 10 -7 'TT 1 L� LL ' L 'L'�i. EX. 1- - ("1 EX. 1- 6L(9 -1, 10 -7) 11 1111 11 1 0 7) EX. 1-6L(9-1, 10 -7) LEE EX. 1- 6L(9 -1, 10 -7) Cam.. (111 4:NY 4 - EX: 1-6L(9-1, EX. 1- 6L(9 -1, 10 -7) L(9 -1, 10 -7) EX. 1- 6L(9 -1 10 -7) EX. 1-6L 9 -1, 10 -7 1404,MAlirlt IIJ444/9044 /i4 tiliti LULrrLrAYirti l' 1 . 9;' i4id41X.WY4,Yil NV+;k,P4 EX. 1-6L(9-1 10 -7) 1 4:'1 =1 1 11 I • a:7 e4.W 14 as i. P SCA 1 I I tW b r1>I ?Ifl SAN 41d fr 96 IL . 1 1 4 �-.F.c H�Y'i'v Y'd -114i 1Y .AW Cam" .th . WWN t,4Y n';} ',9.v3F u 111 110 HO MI 1 PD I11 [To ri 14/4 4 , - ,,,r4'; Wart eitareiltre.1; 91214i.L 'xVt. .f46 W' 14;44...5r.Nl • kdi35't',f914uJ, .Wn l .d 121y t.F 144.12 144.13 144.14 144.15 144.16 1144.17 144.18 43 14 NV 13 :II IlorIlElihi [1111 it .11 i II II I 1 1 1 5. 611 3 i C} 14'i.1 '31 11 � 4_ 1 1 11 L t.) ai EX. 1 -61 ll' HP RO OM 65 01 { 4441.44 a4irrtit d44;1.4.4/41117.n4E1.1 V ..e.. it i.:ts,l4 0.uNktd41i4't. 9. 441 V.hLLit+a19.1 t N'd.;' 167.01 167.02 167.03 167.04 167,05 167.06 1 I' V:- 1 1.,2. „i 11 1412 2 4a2 2.2 .t 113 -. 2 2r2 il'r 41- S1 Iiil r' 'v� I r I ft U t r 64 1i I c.tt 1� 4 u.. I a. .aki- 4.3 rbb 'f8 J'G 4444 .9d 'k: ,l t-1:44.141•73. Art 1 L'.ErE.0 ..ew.a •P;,%1 2;L4• , .. 0 • $9 1 0 ,. 65 04 1 %. k Vz...7idfstiNSX,.'lr 5. 5 1 164.04 164.05 164.06 d,7A1N954Ptl!fibL,GS tik9:4;tit'24'i1LLgairti di't.,g3id71i.J11441 - M1 ilYLl:l: tilF1e1(::i _ )�: 1-6L(9-1, .L ....... . E_ 10 -7} EX. 1- 6L(9 -1, 10 -7) 167.07 167,08 167.09 167.10 167.11 167.12 EX. 1- 6L(9 -1, 10 -7) .__ 1 07 ... 1 l x ..'�'.1.Yt1. a..N ,_:5.:i1.i�3.!%..I rbVaGJN:`+I Si . 1. yJ. iUI': mIJBSL�� .1.Ctivt +.fik'W *a4Si:Yd'u}±'1Y, b' `t T �� ai 4:. 'il':imiii41 �% 1. N e!'. ^211ati1Fllt�t I 1i EX. 1- 6L(9 -1, 10 -7) 35.c8 164.07 164.08 i�t, ara� ,rus+ascu!,dau,.ur9u��.uu.�u7¢l PDF 16 3. EX. -6L(9-1, 10 -7) EX. 1- 6L(9 -1, 10 -7) 65 1 A51C. 4v 1 4444.4--.1 a s u ;tVrt uR -.t LUAU. 'r ;zY, M5 A 1 f 4 , tit . i , 1.1.2.2712.'41 t'1J 10 '168 .1 1 ,f„j't 1 2 . 11'.,il ;f '1 to $) I4 ,f.?..' 1't 'I Y t l ' :7f1 _} t i1 1 I t ir4 a yr rt. it t ...W1;- 4 1• n . vnh if ..FI k'9 ,VNll'.,.r ra 16k ,FlV P , 76 @'riHal;6adk.,u .1 -0;Id;'2,C:,:Ldt.7+� L P 11 .1 35.11 011 1651 _ ..165 Ld 13 1. "x . TSYu1IP ttl,Q e.i1 .111 E4 a5. 164.11 164.12 164.13 164.14 ,: 1 .444''1,9 .641.1AI�k1.4., 139' dP�6' SIb,ILti,k'Sb.lt-0�'.d%1.U,tFrM,i vtcl L1 Y315u I„ tYw I LIE 4: I at •,1 E: 1/4" = 1' -0" ::1E::_ �:11 p� i:l n::_ -_1L�� w:: t IT� _ e 1I : :::::_�IC7 NOTES INDICATED BY NUMBER IN 0: 1. REMOVE THIS SECTION OF CABLE LADDER TO ALLOW FOR NEW WALL CONSTRUCTION. 2. CONTRACTOR SHALL COMPLETELY REMOVE CABLE LADDER AROUND COLUMN TO ALLOW FOR NEW WALL CONSTRUCTION. 3. EXISTING TELEPHONE CABLE TO MULTIPLE WALL MOUNTED TELEPHONE OUTLETS ON SECOND TIER OF COMMUNICATION CABLE LADDER TO BE REMOVED. REFER TO ELECTRICAL DRAWINGS FOR LOCATED OF WALL MOUNTED TELEPHONE OUTLETS. 7 (9 -1, 10 -7) 114 4t .4 1 4 plat -:tk. f 41) .01 Y � 1U➢. sr:��a. ;.A f. 1 sa 4m ,WJ rL ..+d i�Y azti end 11x1 4 .a •�� 44 '..) I I 1 : 1J r .1 1 t_': I 1 1 I t't.-.: I I I :IL : _.1=1 V _EL._ u14 . - ' i ,,, '„ rki 444 ,!a' .S+ U,r. 3 . - A 11i1- f ■1,11 1l 7;i Nt'• - t:i. 11 :0 100 RTIAL FIRST BOOR PLAN - COMMUNICATION CABLE LADDER, SOUTH EX. 1- 6L(9 -1, 10 -7) t 4;9-04; rC`K -k3V lw'I ?PoI 419 / 69 •1 A h1 1 If 4R 3 1ra1J r i (1) Lir j, F, . 1 EX. 1- 6L(9 -1, 10 -7) 1 I r ilh 1 i 41l ..er oti.. faY� REFER TO DC -2 FOR CONTINUATION 514 ' iii, ii ka .. icy 167.13 4 41 P.-09010t ! 1 1 ara t.vtstirrtlru, d a.m4 Sri NM4144 :im;..es;.,da 167.14 167.15 167.16 167.17 G , DC CABLE LADDER SYMBOL LEGEND 1 . . - _- -1 0 11 11 II 11 II II II II II II _ JL JL_JL.JL JL_ x -r Indicates future equipment to be installed. Heavy line indicates equipment face side. Indicates Existing Single Tier Cable Ladder. Indicates Existing Double Tier Cable Ladder. Indicates Existing Triple Tier Cable Ladder. Indicates Cable Ladder to be removed. Indicates New Cable Ladder to be installed. Indicates Water Fall (90° Outside Bend). MATCHLINE REVIEWED FOR CODE M Q pLIAN �� E C NFPA 70 - NEC FEd11NIA Ci I Tukwila fl �Y 3IJILDING DMVI ION RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEER ABILENE, TEXAS IIIOIDP Fac. Code :TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM, Date: 12 -12 -08 Revision 01 -05 -09 95% REVIEW 2 01 -15-09 100% CD 3 01 -26 -09 ADD. NO. 1 4 02 -02 -09 PERMIT SET IIIMINIMINIIIIIIIMIKOMUDIE Project No. WTA. 08098 Sheet No. DC1 PARTIAL FIRST FLOOR PLAN - COMMUNICATION CABLE LADDER, SOUTH 5 MATCHLINE QU PMEN f FLOOR nr 1r - Ir II • I • 0 [IIL 0 T `1 II II I II II I JLJL II II I II II I r 1 11 1 I 1 1 I _1_ L. Ii1!1 � i iii •. 1111 1111 11111 111 ni � 1 11 11 11111111M1111111 IIII 1 Eml e mu r 1 ■ 0 .1 imm 11 1 11 ii v ;L t J 4 1 III 1 I I 11 II II I I II I II II I 1 11 I 2 1 11 1 11 0 2 0 TYP. TYP Y �Y • • ' X 1 6L(9 110 -7) . " 'I.i (6..' '1 14212_, 2. CABLE LADDER SIZE REPRESENTED IN FEET AND INCHES. 1 -OL INDICATES 12" WIDE CABLE LADDER. EX. 1- 6L(9 -1, 10 -7) GENERAL NOTES: 1. EXISTING CONDITIONSNOTE: EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER 3. CABLE LADDER INSTALLATION HEIGHT REPRESENTED IN FEET AND 1 11 INCHES. (10 -0) REPRESENTS 10 -0 ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE CABLE LADDER. EXISTING EQUIPMENT ROOM HAS RAISED FLOOR AT 2' -3" HIGH. 4. ALL CABLE LADDER TO BE SOLID BAR, 2" STRINGER, PAINTED GRAY. REFER TO DC -2 FOR CONTINUATION Aitt 11 I i idea: 1 1 1 � L 1 14 :b ,Ln..l.iit i-llu4L titr.l, 4, 04.44,41, aS..,ar"- 441.41, 441.41, 12.4 7 14402 144.03 144.04 144.05 144.06 144.07 144.08 144.09 144.10 144.11 EX. 1 -6 L 9 -1, 10 -7 'TT 1 L� LL ' L 'L'�i. EX. 1- - ("1 EX. 1- 6L(9 -1, 10 -7) 11 1111 11 1 0 7) EX. 1-6L(9-1, 10 -7) LEE EX. 1- 6L(9 -1, 10 -7) Cam.. (111 4:NY 4 - EX: 1-6L(9-1, EX. 1- 6L(9 -1, 10 -7) L(9 -1, 10 -7) EX. 1- 6L(9 -1 10 -7) EX. 1-6L 9 -1, 10 -7 1404,MAlirlt IIJ444/9044 /i4 tiliti LULrrLrAYirti l' 1 . 9;' i4id41X.WY4,Yil NV+;k,P4 EX. 1-6L(9-1 10 -7) 1 4:'1 =1 1 11 I • a:7 e4.W 14 as i. P SCA 1 I I tW b r1>I ?Ifl SAN 41d fr 96 IL . 1 1 4 �-.F.c H�Y'i'v Y'd -114i 1Y .AW Cam" .th . WWN t,4Y n';} ',9.v3F u 111 110 HO MI 1 PD I11 [To ri 14/4 4 , - ,,,r4'; Wart eitareiltre.1; 91214i.L 'xVt. .f46 W' 14;44...5r.Nl • kdi35't',f914uJ, .Wn l .d 121y t.F 144.12 144.13 144.14 144.15 144.16 1144.17 144.18 43 14 NV 13 :II IlorIlElihi [1111 it .11 i II II I 1 1 1 5. 611 3 i C} 14'i.1 '31 11 � 4_ 1 1 11 L t.) ai EX. 1 -61 ll' HP RO OM 65 01 { 4441.44 a4irrtit d44;1.4.4/41117.n4E1.1 V ..e.. it i.:ts,l4 0.uNktd41i4't. 9. 441 V.hLLit+a19.1 t N'd.;' 167.01 167.02 167.03 167.04 167,05 167.06 1 I' V:- 1 1.,2. „i 11 1412 2 4a2 2.2 .t 113 -. 2 2r2 il'r 41- S1 Iiil r' 'v� I r I ft U t r 64 1i I c.tt 1� 4 u.. I a. .aki- 4.3 rbb 'f8 J'G 4444 .9d 'k: ,l t-1:44.141•73. Art 1 L'.ErE.0 ..ew.a •P;,%1 2;L4• , .. 0 • $9 1 0 ,. 65 04 1 %. k Vz...7idfstiNSX,.'lr 5. 5 1 164.04 164.05 164.06 d,7A1N954Ptl!fibL,GS tik9:4;tit'24'i1LLgairti di't.,g3id71i.J11441 - M1 ilYLl:l: tilF1e1(::i _ )�: 1-6L(9-1, .L ....... . E_ 10 -7} EX. 1- 6L(9 -1, 10 -7) 167.07 167,08 167.09 167.10 167.11 167.12 EX. 1- 6L(9 -1, 10 -7) .__ 1 07 ... 1 l x ..'�'.1.Yt1. a..N ,_:5.:i1.i�3.!%..I rbVaGJN:`+I Si . 1. yJ. iUI': mIJBSL�� .1.Ctivt +.fik'W *a4Si:Yd'u}±'1Y, b' `t T �� ai 4:. 'il':imiii41 �% 1. N e!'. ^211ati1Fllt�t I 1i EX. 1- 6L(9 -1, 10 -7) 35.c8 164.07 164.08 i�t, ara� ,rus+ascu!,dau,.ur9u��.uu.�u7¢l PDF 16 3. EX. -6L(9-1, 10 -7) EX. 1- 6L(9 -1, 10 -7) 65 1 A51C. 4v 1 4444.4--.1 a s u ;tVrt uR -.t LUAU. 'r ;zY, M5 A 1 f 4 , tit . i , 1.1.2.2712.'41 t'1J 10 '168 .1 1 ,f„j't 1 2 . 11'.,il ;f '1 to $) I4 ,f.?..' 1't 'I Y t l ' :7f1 _} t i1 1 I t ir4 a yr rt. it t ...W1;- 4 1• n . vnh if ..FI k'9 ,VNll'.,.r ra 16k ,FlV P , 76 @'riHal;6adk.,u .1 -0;Id;'2,C:,:Ldt.7+� L P 11 .1 35.11 011 1651 _ ..165 Ld 13 1. "x . TSYu1IP ttl,Q e.i1 .111 E4 a5. 164.11 164.12 164.13 164.14 ,: 1 .444''1,9 .641.1AI�k1.4., 139' dP�6' SIb,ILti,k'Sb.lt-0�'.d%1.U,tFrM,i vtcl L1 Y315u I„ tYw I LIE 4: I at •,1 E: 1/4" = 1' -0" ::1E::_ �:11 p� i:l n::_ -_1L�� w:: t IT� _ e 1I : :::::_�IC7 NOTES INDICATED BY NUMBER IN 0: 1. REMOVE THIS SECTION OF CABLE LADDER TO ALLOW FOR NEW WALL CONSTRUCTION. 2. CONTRACTOR SHALL COMPLETELY REMOVE CABLE LADDER AROUND COLUMN TO ALLOW FOR NEW WALL CONSTRUCTION. 3. EXISTING TELEPHONE CABLE TO MULTIPLE WALL MOUNTED TELEPHONE OUTLETS ON SECOND TIER OF COMMUNICATION CABLE LADDER TO BE REMOVED. REFER TO ELECTRICAL DRAWINGS FOR LOCATED OF WALL MOUNTED TELEPHONE OUTLETS. 7 (9 -1, 10 -7) 114 4t .4 1 4 plat -:tk. f 41) .01 Y � 1U➢. sr:��a. ;.A f. 1 sa 4m ,WJ rL ..+d i�Y azti end 11x1 4 .a •�� 44 '..) I I 1 : 1J r .1 1 t_': I 1 1 I t't.-.: I I I :IL : _.1=1 V _EL._ u14 . - ' i ,,, '„ rki 444 ,!a' .S+ U,r. 3 . - A 11i1- f ■1,11 1l 7;i Nt'• - t:i. 11 :0 100 RTIAL FIRST BOOR PLAN - COMMUNICATION CABLE LADDER, SOUTH EX. 1- 6L(9 -1, 10 -7) t 4;9-04; rC`K -k3V lw'I ?PoI 419 / 69 •1 A h1 1 If 4R 3 1ra1J r i (1) Lir j, F, . 1 EX. 1- 6L(9 -1, 10 -7) 1 I r ilh 1 i 41l ..er oti.. faY� REFER TO DC -2 FOR CONTINUATION 514 ' iii, ii ka .. icy 167.13 4 41 P.-09010t ! 1 1 ara t.vtstirrtlru, d a.m4 Sri NM4144 :im;..es;.,da 167.14 167.15 167.16 167.17 G , DC CABLE LADDER SYMBOL LEGEND 1 . . - _- -1 0 11 11 II 11 II II II II II II _ JL JL_JL.JL JL_ x -r Indicates future equipment to be installed. Heavy line indicates equipment face side. Indicates Existing Single Tier Cable Ladder. Indicates Existing Double Tier Cable Ladder. Indicates Existing Triple Tier Cable Ladder. Indicates Cable Ladder to be removed. Indicates New Cable Ladder to be installed. Indicates Water Fall (90° Outside Bend). MATCHLINE REVIEWED FOR CODE M Q pLIAN �� E C NFPA 70 - NEC FEd11NIA Ci I Tukwila fl �Y 3IJILDING DMVI ION RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEER ABILENE, TEXAS LitimpiaNtialintelL INN FUTURE PANEL "DP4 01111111••••■• I =4 \-AGB-1 EX. 1-6L(9-1, 10-7) E0IMPN1ENT f[PPR EX. 1-6L(9-1, 10-7) GENERAL NOTES: DCGB-2 1 II ir II 11 11 II II II II II I II II II II II II II II II II Il II II II II IL ll_.11._11 .11 UJLJ 11 11 1 11 11 1 L_ 2 TYP. 1 11 11 1 11 11 1 1r 11 11 11 11 11 11 11 11 11 1 "m il 11 II 1 II 11 II L 1 DCGB-1 FpAUTNUEnp 1 BRG1- II 11 1 1 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 1 11 11 It II II II II II II II II II II II II II 11 NEW ROOM TYP L // ll _ ri Lv F1 1 f I I I 1.. I II -7 ii li 1 11 1 L [1][jj[]1 :11 1_1.J [3] MATCHLINE ( 1 51./ -55 05 55. tilt-nn int '5. 'It ni te nig L Li. 55 4. in it ,ntl . 5.5 Li• L ° , 1 41T , 51 nL „. 150 _II IMMO 01 1 CI. 02 '150 OS 1 0.0 0,3 . 1 15C. 150 '10 EX. -NY I . 1. EXISTING CONDITIONS NOTE: EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND/OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. 2. CABLE LADDER SIZE REPRESENTED IN FEET AND INCHES. 1-0L INDICATES 12" WIDE CABLE LADDER. 3. CABLE LADDER INSTALLATION HEIGHT REPRESENTED IN FEET AND INCHES. (10-0) REPRESENTS 10'-0" ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE CABLE LADDER. EXISTING EQUIPMENT ROOM HAS RAISED FLOOR AT 2'-3" HIGH. 4. ALL CABLE LADDER TO BE SOLID BAR, 2" STRINGER, PAINTED GRAY. -•• — RE TO DC-1 FOR CONTINUATION [i] , L //' , 71,‘ , t1.9 W 1 1 1 1 EDM 011 1 B- 111111111 \ --FGB-1 [1141[DE AN co EX. 1-3L(9 1 EX. 1 6L(9 EX. 1 6L 91.1 1 EX. -6L(9 EX. 1-6L(9- X. EX. -6L(9 11111111111110111111 111 1 11 1 1 1 111100 1 1 01 1 111 1 imuimim II II II II II II II IL 1 0 1 EX. 1- L 9-'1 ri 00 0 1 101 11 1 1 • 1: -6L9 1111111111111.11111111111111 a 145 51a if Of noit iit/ ;.g 15 15.1 n nitt-ilin NI ail iiii 4.51 511 04;;..au 6o- 75. 55 01 -.54535) 1 n in 55R • inn PL. -a.- 55 55, 35 1 ;j £ k 1 1 Pi1)1J 1 -- 1 11 1 1 1 111 11111111111 11111111111111111111111 1 11 1 p 11111 111 101 1 111 111 1 1 11 Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12-12-08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET 0 01-15-09 01-26-09 02-02-09 1 4 Project No. WTA. 08093 a aminicuml 10-7) , i),111.; 1 , . 111111111111111111111111111111111111 ti • • ri.: Y-; tR EX. 1 6L(9 10-7) t •1;',1 1)':1 1 IL- lf:t r1:ci ; Y)'I 1 1:.‘•1 1; 1. 1 ■ A 111111111111111111111111111 11111111111111 1111111111FR 1 1 10-7) lit I ■;•:: t. ,Iht ant Li nit Li nni L5-.55 int. ttin 1 1 'I.)I 1 • 1 11111 iA; 1j. CtiliH I i i 10-7) 10-7 eta, iVir anininon 'F'tan•hir`o, 55' 5.t. •5•1 itn n1-4,.,S :Lne, ;n1 I •■•;;:. ; 1 I ' J;, 1 0-7) 1$7) 0 1 1 1 Empai 11 nnnu (,) u_ 0 r 1 o 111111 111111 1.1 101 71 0 LA 4T1 17 1 11111110 55551 t-ttitt..19 , 1.6 •I'55 itittnLinti-1514-1 1211,15 tad', lin-5111 IL -55 .A Ci5 nti Lti -5,51•45115 1.1 71 51.1• 10-7 I ) tiki LT71151 ., . ' :ittni 1 1 '' l ( L:: i 101 1 111111111 1 EX. 1-L(9- 10-7) , im• 3 SOQJC - 111 2 W °' th I- IT 3 L 14 in a td. 2 EK yr. V0 W W ▪ as l• -1 in — > Z C 0 < Sheet No. DC--2 PARTIAL FIRST FLOOR PLAN - COMMUNICATION CABLE LADDER, NORTH NEW PANELBOARD l 3 BOX 0-7 11111 11111011 NEW 0-6L(9-1) P WWII& ..•. 11 1..L5 05 int nit, itt .115 t•,15 51,. L. f int, nin inn • 1 a. 1Y "4 • 1,5 , 1 .! I i • ■ .1 , Zici 7 . 1 10-7 ,"ti Una 511. din id IL- ,L5555151 ' t5; titi .55 55) 155 Inn 10-7) Wrnrnw SCALE: 1/4" = MEE it 411: I— NOTES INDICATED BY NUMBER IN 0: 1. REMOVE THIS SECTION OF CABLE LADDER TO ALLOW FOR NEW WALL CONSTRUCTION. 2. CONTRACTOR SHALL COMPLETELY REMOVE CABLE LADDER AROUND COLUMN TO ALLOW FOR NEW WALL CONSTRUCTION. 3. PROVIDE RUNWAY SUPPORT B-LINE SB-2113-24-GR OR APPROVED EQUAL NEWTON PRODUCT, AND MOUNTING FIRE RESISTANT WOOD BATTEN. PAINT WOOD BATTEN TO MATCH MOUNTING SURFACE. 4. EXISTING TELEPHONE CABLE TO MULTIPLE WALL MOUNTED TELEPHONE OUTLETS ON SECOND TIER OF COMMUNICATION CABLE LADDER TO BE REMOVED. REFER TO ELECTRICAL DRAWINGS FOR LOCATED OF WALL MOUNTED TELEPHONE OUTLETS. IV; -••• • i Y7 EX. 1-6L(9-1, 10-7) • W ft 4k 0 fain Natal PANEL "BPPA2" EX. 1-6L(9-1, 10-7) 7. i PANEL "BPPB2" - ,1 _......._.,_ 1 1 n • .14:1 a4. .ro EQUIPMEiN1 OpM, 5.55455•10555iir-i 1 7:3,01 -i! 7 r ,• '6 . 2! ; !.o a; VI inn int n t 515 5.5 nin • PANEL U)T ",PP1-1" ANALASER ZONE 4 Bal< 1 EX. 1-61.49-1 1,177 1-11 0 17 0( 71 1)7 XFMR 7. • UTRL1-1 11111111 Itur 1-6L(9-1, 10-7) if. 06 l 6. , 0.10 "i -+ i 11 Td .41 511 1551 • ini• An-liiintini cl-r. 5.L intin tin • 55-107 155 i 3 irtLinni5.512t1•51 5,11 -515.1t5 L5.05 ii11-1111 -i,. .-1-11 int 55 tittnint n15-in. 511 .55 .iI5 ,55 ott ti1 1 EX. -6L(9- 10 11 1 1 11111111 ;• flA ) 0 1 7; ) il I I 01 I II 1 1 I I t 1 EX. 1-6L(9-071) EX. 1-6L(9-1, 10-7 11 1111 ; r' 4 [It', tin nil Lin 5 51 lin iii 11 r ,55 .55- -11L 6 a. a; 415 1 r't -•_-_,------ ■• ,^ M ^~ M•, 4, u - • • --•"•--•-. ^ L.-. -• • ■ '• • a.. • .a.1 ...a 01 .0. 5.4-5 55 55 Oil 121 •Lif 515 5 15-155 it& I a-u-a3-M,..3.4'..41 V•15 ntlinn•ini- 5:14 Lin 5 .1a • ni•ntil• init 015 ' n5,5,55i.515-1,5 .t.a 111 nn1 41 in-A) 5.1 11-1n, 1 7 0, 0 9 175 0 0 • 75,04 175.05 5 .00 175.07 17,5.08 175 0';',1 'Y75.10 175.11 175.12 75.10 175 1.1 175 175.1e 175. '7 .... _ ..... ....... ..... EX. 1-6L(9-1,10-7 EX. 1-6L 9-1, 10-7 -1i1••55-,15-5155,5 Li el 05 ca 111 11 (5,5-1L5.5 -Lb 51 -ii-11 llJlll i di fa 111 . 17102 170.03 173 Oil 173 05 173.0f: 17.3 173.00 173. 7:3 10 EX. 1-6L 9-1, 10-7 1110111111 PARTIAL FIRST FLOOR PLAN COMMUNICATION CABLE LADDER, NORTH . t zi 1 1 , 4 itil silLY n5• 555- 555/ 1 ; 77 5535 inti .i. 1 7ii0ll 1 BATTERY 1D BATTERY 1C 111 I 1 515 tin i il 15i 511- Lii--111 .55 155 1 :IV, !II 1 L-155 IL-56-J 251451 1i IL Li int 55-i51.555i11115-5 54-14-1-111 1 .'11. '24; An! it]; 173.11 . 173.12 173.10 173.14 1? 3 1 7:3 0 1-555.7:5 45 5. 04.i. -kkit in.L5 5 115 yr 5 ntit MR. 1 113 ELM.- 0101 BATTERY 1B REFER TO DC-1 FOR CONTINUATION BATTERY 1A UPS-1 Era DC CABLE LADDER SYMBOL LEGEND Indicates future equipment to 1 ..... 1 be installed. Heavy line indicates equipment face side. Indicates Existing Single Tier Cable Ladder. nnnnr Indicates Existing Double Tier Cable Ladder. Indicates Existing Triple Tier Cable Ladder. -1 Indicates Cable Ladder to be 11 11 11 11 11 removed. 11 11 Indicates New Cable Ladder to be installed. Indicates Water Fall (90° Outside Bend). REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC rai J. 1 2009 mum RECEIVED CITY OF TIJKIMLA FEB 0 5 Aliiq PERMIT CENTER WTA - 08093 COPYRIGHT 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS MATCHLINE ---- ,r. -,r, .- ,F --,s FLOOR 0 • 1I •II •.I II' II I " .1111_ j I1 II ' II II' I TYP. 0 II 1f, •4 .1 II h .L. 0' 1) O immuoimiteolooloommon Rim v• IM tI Li 41 ft- Ph WWI 5. CONTRACTOR SHALL TEST ALL CABLE THAT WILL BE RE -USED. 41,1 1 r 1. F i. I • ui *ll 44 „,I ;ID' 4 471 44 441 4.4 11.11 ... 4. ALL CABLE LADDER TO BE SOLID BAR, 2" STRINGER, PAINTED GRAY. GENERAL NOTES: 1. EXISTING CONDITIONS NOTE: EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. CABLE LADDER SIZE REPRESENTED IN FEET AND INCHES. 1 -0L INDICATES 12 WIDE CABLE LADDER. 3. CABLE LADDER INSTALLATION HEIGHT REPRESENTED IN FEET AND INCHES. (10 -0) REPRESENTS 10 -0" ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE CABLE LADDER. EXISTING EQUIPMENT ROOM HAS RAISED FLOOR AT 2 -3" HIGH. REFER TO DC -4 FOR CONTINUATION 1_111i 11 1 11 all ill 1111 ,. _ . 1 il l I I I ` ............. F ,:: 51 i. l I I 1 f I � r h � 1. I .s � , l., n', /'.�r 'i. fnr r1, 1 .9 +nA JG l t" i '.. `, ,.. .. . 1 l f I I ... � It ll . .'3 I .r , .. � i ■ 1 t r. I r.' I ! Ili! EX.1 -: L 12 III -- �1 _ I Y bfJJi 1 !' �I , . :: r - 1 111 EX. 1 12 -1 l� • • � !�� � � X11 I � �`: A all �! 1 �! ill® I�I�I�11ANi11�@ i�l�l�l�hl�li�l�li►�Il�l�l�ill ice) ii�■I� �1�311i�1tl�1��1 , J �IIiID l II II1 • I I�I�i �I IitI I l �I�lll■ I INI I1I5Itlmo • I� . °� a ra 1,'wR lfl'f�SIR ':JY.'i0 N'1.'LE n .. F ,.. :, .,,: .. .,..� i. t 4A . rF 6. ACIiu11 'df{u.,N. 1. CLdliYS4: � .t A r b f, h J Lk M.S,.AL �„wA tlmWh3h .s6 r, dMslrb 143.05 . Se t,S i1,.GCk. ! Ir- L .. 1" 143 UU 1 43 C / 143 0$ 14,1 09 c 3 1) 143 143.10 143.11 1 143.13 14315 14316 14317 143.18 A-1 •J:.:d,1 .d., OIL Md. Ta!'lam1 41 ;,cMe 6.15 tUpt 1544 ir"u, 1 I ;y ri. I � 414 M, 41 .v�r 154 N1 xt - • r„I •I il: 0!.. 146 r , -1<:� I I EXISTING PDF TO BE _REMOVED_AND REUSED. _- 45 I I ; I I i { 1 vLA1.Y.i Lkad!:iL l!: ';54'Lthb' "'i' ': r ' '! I b � rt e.��t.1. tl z te:l�a z: z lro- a t 6 A,Ead 1u n,u'u.,,vd Jfl u.s ,z::: 5 ;m X41. �.,er - �rrr ! t '.. •2'-0" ; r� .,ka cns:Ru n1n t IL ,: eaJa TYP. 144.02 144.03 144.04 144.05 144.06 144.07 144.08 144.09 RELOCATED PDF :IkKdu/Y14•W PSfr 441,11 /41,444, s L , 441d%' �IltutiG i.Ni'AiiAi�Ert'1. Y e 5 .dU1:'�4,1: d a, 1w 411134r'.IYu11441 6..a,' ,,1.:444,14 W11.4 144.10 idT:d.ka1� 144.11 (16) -350 MCM CONDUC EXISTING PDF 42 TO M REUSED TO FEED PDF MCM ND C O UCTOI�S PE 1 1;1 - .�1II v 44.12 144.13 144.14 144.15 144.16 144.17 144,18 RS FROM B TO BE . ,POLARITY. 1. 1 1 I I I i I 1 I h <R A f,p -u�. S ti 1 t', a . I x 1' l .. ih I I 11 }4 '�fi Ll l e .4Vt: :e i': 72 I`. 1 , 'q1. 1.1 -;l II . I A':` t if I +.0 td I, 5,1 0,1 r, :la • <f . ,i 1 ! �v. f{ L N " 1111 a - 1 1 . y .I. 144 14(3. 15 7 1 1 L 4J I. 1.rv<F l3vI U1W11 : d.... Ir, NL.., 1... t., t414f41> 4; I114.11ArMNU .uLLS. }e6U1 111l444/4J14 - 4I1111 u.141 c -441,1 3.u1t .1f1,.tti. . rtr, N. � ..1 ,. uv 4 JAN 5. ! n"tSl..els44V V 1/,.o-. ,at�il ':... a '.. t i sr t ,. IY,! 1 1 ,. tangy ;f 1' y , ntrd Ji ,l, Ia.Ysk rtYl m;:LK,YF .I.0 Iu,:tYCIu.�1111uW1 L ,'4, .i n.. E I i. d td 142.02 142.03 142.04 142.05 142.06 142.07 142.08 142.09 142.'10 142.111 42.12 142.13 142.14 142.15 142.16 4 .+If ., r .t hg: '«1 4.11 pel u;J t•14 SCALE: 1/4 = 1' -0" EXISTTNG 8 -350 (} MCM ( -) CONDUCTORS FROM H- TAPS° 19, rYF 1i aT nk'tztval7l s.4 1z.,tmwix un.4•.x,*teii71.1:,k .rr rw e' nett +h.. 4441,444, EXISTING (8) -350 MCM ( +) CONDUCTORS FROM EXTERNAL RETURN BUS - Y ,I i:'N ,Ei i..e.'r:.YS.urs,t -1 ufi: >A:Y::4 142.17 142.18 NOTES INDICATED BY NUMBER IN 0: 1 i � 1 <F it. 01 1.L1 3 ::. REMOVE THIS SECTION OF CABLE LADDER TO ALLOW FOR NEW WALL CONSTRUCTION. EX. 1- 6L(12 -1) 2. CONTRACTOR SHALL RE -USE EXISTING (16 )-350 MCM CONDUCTORS, ((8) CONDUCTORS PER POLARITY), FROM EXISTING PDF 42 TO FEED PDF 144. 3. CONTRACTOR SHALL PROVIDE THIRD TIER ON TOP OF EXISTING DOUBLE TIER CABLE LADDER. 4. CONTRACTOR SHALL PROVIDE NECESSARY SUPPORTS FOR 1 -6L CABLE LADDER EXTENSION TO NEW PDF. PROVIDE 90° WATER FALL DOWN TO NEW PDF. WATER FALL SHALL BE A MINIMUM OF 8" OFF THE BACK OF THE PDF. 5. CONTRACTOR SHALL INSTALL NEW (16) -350 MCM CONDUCTORS, ((8) CONDUCTORS PER POLARITY), FROM H -TAP INDICATED (REFER TO SHEET DC -4). J/ I u JSI 171t S EQ1,11P1h,IE J - I ! .. ..... _. .1 Jx. a 13 4.I1 1 NEW (8) --350 MCM ( +) CONDUCTO 5 FROM EXTERNAL RETU BI .S' 5,r `, , Y ! lY . I ■H did 1111 3"1 41,91414 143 841L S101F'4111: Phil NEW (8) -350 MCM ( -) CONDUCTORS FROM HTAP l7c 7t ter t.' " - ' 7fY �/ t J3, t ! I J 7.. �' 5 ;:t I 1 ] N ',F .Y ,td „& >67�',4 P.1/ xVl �H vS+41>: I9 S, I f��a.R f d • t 4 f �'� 1. 4 V t b .3. ,1114 h�S3 A L.! 8:P 44e b { I 1/:u A u. ti W l ! : i r 1- NE 1 11 `I �I \ \ Iiial `I! \1 \ � \I� \�I��II��I \�I \117171717 % l 414414114414 441.1141 ! {14011,111,1.. 1J..LSf' laid ➢...e:Y.Yl6111Mdt4w:IJ10.4ti2. 1i11l 1/.i iii , 1114110 , 444114111F +00014441114144 x11. 4 '11.U,Ylfd'rLJL11.J1111d11Y(,YI L.Y!:d 11iii Mat 1("11iil.eS.LA.il.L1141 iii1411:1,:4. ? .Nl4111 .41:4.4 n4e :c: - fJi;{t11 .[,JSUa4,1:. 5, ct .1 ,., ;�'e.l,ua 4, ma,tlnaiuCa ad..4.u7b.Frs:fii: 167.01 167.02 167.03 167.04 167.05 167.06 167.07 167.08 167.09 1167.110 167.11 167.12 167.13 167.14 167.15 167.16 167.17 166.03 160,04 166.05 166.06 166.07 6 6 07 1 B US 166.09 160.10 166.11 166.12 16613 ,kV1 4,1WAeltillli}. e.lf,l ILIL1addd511 .L' , I 1 '' Cc kkIJf7Jm9Poi,bi&I otiF. �.f.n'VhGk„dM'..Nt�.a11311SfVth ldls lJl of `;,64lekwffiCi_tP:c:dl1'u'S1NIt.W :: In0.;. 5dirYrY, l. antlLaR ud lut, BdALdtltfnxrbni: wlu: tdSLr':. ro-mw .rtkN'riF ;a1HY,4e.dk(r''L' 164.04 164.05 164.06 164.07 164.08 dSI1W t56tW,f 3t1v,t:5IixY,G.i.�NSW}Jp Yu..:1;23 x..i1LsWCd°d ma 914 141 LL.1,7a:IW_th 1.11 +ililSshGkdYiGb..>'JEldikut L . /�. I 1 1 } /v �I I 11C l� li ..:r : ! I I. i 1, +,M Sn 1il 94-116-4114-11114411, e.l 1 n s 6i t ttJ 03 144-'641-111.62-11 •11/ 4.11 445-111-11111111/4 rG l,A >tl .0 Y � I 1 1 rJ S.d 2 -J I' '1 tl' v..t J L du rl Lh i:k 4 NH li 6L L1 4id .J 4A'1 sFV i-: 'n.1 el , I 1 .J0 06 1 (7(1 3 L _ ` d IC l[_ a _ =_ =C! __ �_._.__ ___�..___ -1_ 1111.__ - - -- PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER SOUTH Yk r ■ r 7- i ! 1 F. I i 1 ".I t �� 1 , I1 I zrJi[�M w 1 1 .:f n,. Ivul °' i,;P FL' tdr 1114 i-df4t JA ct rJPF7 5,tl fu. n'm itd e/' 1;:r 1 a t ry : IL 411 Me 1 : + , 4 4 1 1 10 401. '14.44' 4 ,1 1 1. t & 1 rx a mdd, di: w,a•, RE REFER TO DC -4 FOR CONTINUATION ,. 1 ' l J ICk I � 7C? d t I �I 4 r a9 rFV,' efu uft n ea: k.7.i4 t.r .k ... YAL*Jtp k ert MI ,dd 1411 • &- N '..' OCATEC PDF a1.4144141"dµx44tt11.10 1, 65..110_....165.1.1 _._ 165.12.. _.165. .. 1 164.11 164 12 164.13 164.14 . 4.14 ie.J.438,tmtzt Ltli i}$t'lllf: L!N U , eL7 44411/. x1104 /41L1ll'ti1NiSi5S 6 l • NI! f. DC CABLE LADDER SYMBOL LEGEND 4:1 Id - .a 1 1 5 n tf9 it 1 ■ dl on rv! - w7d yrS d➢ , ni �'.sli lkr 11 I 1 1,1 :14,15 ,.I 1_- _ 1 x Indicates future equipment to be installed. Heavy line indicates equipment face side. Indicates Existing Single Tier Cable Ladder. Indicates Existing Double Tier Cable Ladder. Indicates Existing Triple Tier Cable Ladder. - 11 -- 1F -Ir- Indicates Cable Ladder to be II II 11 II II II II II 11 11 removed. Indicates New Cable Ladder to be installed. Indicates Water Fall (90 Outside Bend). MATCHLINE REVIEWED FOR CODE COMPLIANCE NFPA 70' - NEC FEB 11 My c�WOfTukwl►a BUILDING DP/I ► .: RECEIVED CITY OF TIJKWILA FEB 0 5 ?nnq PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS �t. Lio �'10 J9 i3 NO " /OIVAL ' , ,Expires -,� ° f3� k CO O �� 4 O clf.) 1--- 4 c:7) CD O �Z 4 k °' (4 c( '` k FIL.. i Lu is (; Rc`' 4 N ....1 Qf 1., lu - Fac. Code :TYKWWA Drawn By: IM, PS, ZJ Designed By: KQM, DL, ZJ Proj. Mgr.: KCM Date: 12-12-08 Revision 01 -05 -09 2 01 -15 -09 01 -26 -09 4 02 -02 -09 Sheet N0. DC -3 100% CD ADD. NO. 1 95% REVIEW PERMIT SET Project No. WTA. 08093 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER, SOUTH LASZBE-S69 (SZE) XV4 081:11-969 (SZE) 9 09 Z. S'arX3JL 631 31-111EINze OOS 31.ITIS 63Allela 3E1V7-111A 3ND I 1147F—L-04494k 0 uJ 99t96 NOIONIHSVM ‘1171M)1111 HIT1OS AVM311/9 Z9901 sseursnq Lin LV 0G 71/7g nooy iN3141d#703 Ch BATTERY BATTERY 1B , ., .:-.- 7-- ----r - -7,1 --1 -' ; -7-- ,---, 4'1 • • • ,----1, -,a, .., 0., ,-.7.,t ,L-,.... -,t ::: e: , E--:1; _ 52 -...- -,--. , . : -1 =-_,-, I dii:--5, .7-(1 0 =1--,„„ _.,,,„„1 1,- uu, , , . , . . ._, , v- ; .,,.. 1. .,-, - :i,• 7 : . ,a - : •'-', :,;-. : 7 , , :•.: ..,", : ' --.:, • -'4: - 21-: '--,:i'- 'al-,_ A71 4;,',! : .16 ; ; ;-'..; ' - -1 : 17" i 1 ;-:-." 7 v: -.. 1 1 '-. .:- • • . ..?, !:":: ...j 4 -,::: a: , 7a. a'.-',_ ,-, :,-- ..-:: -.. 771,,, -,: - ,F1 ,; rq - 't "-=-: ,.: .-::- -=-..., ,a ,•: '7' .:: il :-7- : :, ;-... A ,7; - ,-- -:.t. -.I 1 •-,--- . ,-, :.• H ,t, 2z -i 4- :i-9 7..... , ::— a - A ...„ , .,... ,T,, ... 7',..1 4. .:--1; ' ': . `;-- ; • i , i . . . . . • . ! LU CO 0 , I- : , . , , , , I- I- : : : .:, ?, _ 7,-,,,,,,: -,•?. - , , a .., ...:_ .. t 1 , .4.;'-':, t'77:-.- 1 ..'', 77 ,'.77 72 -.; 7: : 7 ;e ra.; a .:'- . -7-: :a .._ a -,- Nz7:' ;.. - . ,-..-:- 7.1 , I'-. ;--: j,, • , .__ _ - 4,:, •-- -,, ;='; T, --__ - I:,':-.Z :--.... ; ,- t ,:'-:4' , --;:t ,..F. :-.....„, 7 11 :::4--. ::‘..:6 77 ■ar:: '.: -' ,r'? ... ': 7 --. . P --„,1 ...: P. • ..1, ---. .. „1_____ '4 -. .-.. -.. 1 , . . • ; ......._______ • , 1 ; 1 : . : . • , ! , 1 ' . . . . i ■ , f ! , ■ 7.4 ----- -i -,--- t L. ;=- -- 4..-.4 .,- --.z- _ 4'7 m-- .a..-- -a- :,,..„. r-- 5 ...- ',..--- -.72- '777 ....--: a .... _ 4,- , : U_ :..1 7 . , _a a__ _ r ,172 -41 `4==--- '-- . : 1 1 -.:;...': ; "..---; -2 •_.„ , CL uu .4 :a--; c.-..,,,,,, : ,,,,-.,: ',- a a t.--- *;,, t , -, 0 1- ,......t, . . , 1.- z„.-- ,;. Z < 4 Z 2 ' .„ . . L A 54 0 ;;', ,''''. -': . 1:: 8 F: ...i..,-,; ,,, ,-,,, . 9.-• GO _.1 ,,-..:. :.-,. .- . r : 7 < ! Z .. -a a' 0 5 0 22 . .-- 77 ,....1 .c■i 7:4 :a.,= .- I= < ' ,,, , 5.. ''''-'; __.,„ '-,-.7, •,,,- 1-,, , . ,-.--.,-, 0 ''" .4----f-, .., --,•, ! --; : 3 u Joe u_P-- ,,,,,,, ----.-. : C): 0 ' “-- ;', '7 T.-1' =.4 ,-'• -', 1, 2,-- ,-",,,,, h---- ; ' 1 ,a; 7:- 7 ; 3 ..., d ._ ,_4 2 CI : - Ce Q- CC ts" -.1 H-, OLI. LU LL 'a'----- 1; .-, U-0 2° ,,,,,--, i li&N•L.:-,, ;--.' -:..-. ,2; .--:- i - „. -- .•,, • , k3 :I-- OLJ- :.,i : ::.-e." 71:: It‘lall 7-i GO i--- , -.a' .,•,-- - .:- :,-, ,-•-• .„, .r. - ':-''' D m= 00 • ,--,',.-,= __ 2 -,---0. IME -::i. , - ---a ,"7-r 71 ....-...= •=, ! ..' -:=-'1 ;-._. -:.; -- azi lo ! ,2,=. '1'; -. 4,1 ..,... , -- i Z ! , : -,.;-, - IMM - ...2.0'',--]---=,; 171::---4 --a .=-- re CC .,,-. I CNI I . I's I t . ' 11 °-4 < tri ! _, _, - 0 - 1 2 u co.----; i LL i I ' 7:- -,,,, 7.,. ..-... "" "" 1' • 1-- I -___ ,6 LL- 1 , 0, , cL , + R., 2 2 _ _ 0 2 20 Lo U_ CD Et i e;'..:D ' , e:-„,„ _ '-',.,-1 ;-,;,' :2 HMI EMI NO MR :.-: :-:i.:. .,i - o or,"/. , 63.D I- 2 r.s....11,, „-,-: LO i_ C700 ILL0,..2 '-,:a W 0° XIV' q= tO Ili i ' sz FO.' z F- E3 F.2 i - ... c? co NMI zct Willi wol7 z o = z 0 LU / 0i ro- ce -...-:: 0 1- 9611 . (. 0 , SE# Oo - , ME z m 111111 I= LO 0 3n_NWIE 0 cr) z . 7: . : • -.0 L W 9 - RE! 1-7.4 9Y83 2n±4 EX. MATCHLINE z 1= z 0 LL ce 0, 0 I- CC 111 LL 111 . • EU ce 0 O) 0 cd ii cc u_ ammin ---- 0 c ---1-- a_ impliani .arailiENQdMMIESSEMINIERAVIIIIMP-1111121616=1=111211MINEMEIBMWERIMMIZIEllarrAINEMENEMEIIIIIIM OEM =2)1MENEM miummaimmismirisaiiiminewismanor•mirmemimmonsizimzumnsmzeiNEMSWENiinninlim 1m deism VIEMMEERWIENIERIMIELMEIMINIIIELEINEENImumiumotwommiimummiumpramr NpziniwimnBimmimmmuummasmmimmr-mmmmmirm•nmavt•mEi•mmmin•Evuanzmawimmm!E•mfngwammmmu•su•neaasrmmosinmrzrgu or z a_ 0_ 0 li tritwantallimilturAIEUELEMII IIMMUMIIIIMEIWiliMINIUM1111111NIMINEMORIESIMENEXIMENMEll diumssoummiummumummirmEmErivissminuenailmumnammummummEng 116.1111161MINE MINIM Z # OVe:10 afrallA /11111 7:47= •H„ MM nem V .1- -I .-11 MM Z z a := 0 (. Z 1-- A , R. 0 x Lu 0 LU :.--- MSM MM , MM MEM Fac. Code:TYK CC LUO Z W <0 11.1 .1 —1 M 0 <m 1 0 z uj 0 0 w 0 uj 0 0 0 0 00 cc cr 0:1 tr CC 0 IL CC 4(C sc GENERAL NOTES Proj. Mgr.: KCM Date: 12-12-08 0 z 6 PERMIT SET 0) CD CD co 9 c) CY) 0 a) - -CD CIS CCS — 0 0 0 a) L ..- :g i= 1,5 .- 0- I- i- a), a = a) E cr tn) 70 a) CL a) c = 0 's= CI. 5 W 0 0 1- - a) a) as co 0) 0) Z 0 c 0 > 0n 3 :1.c caa1a .) s 1 1a) 5 L2 C 2 13 -E tC8.0 O 47_1C-3 :L2 x t . 8 L 1 = co -Cc Wa0 EO J 5 a) „, iTI co 73 • 03 :CI -Ft C .0 = 4:-"" C -I .E0 -S -9 Project No. WTA. 08093 0 z ce ci LIJ Z 0 0 < 0 I- 5 Z 0w (7) CO Z Z LLI 0 D 0- CO IX kDO WCOLL PERMIT CENTER 000 00 00 00 00 1— w w w w _J co CD Z CL E< W 0 :t(4 IX z 00 uj> W = 0 LL. LL. a.- < I- 0 co 0 07 z 0 > Z W LU < Lu> CL Z UJ LU LU Z W 0/) W -j, ■-■ CO CC I- 0 D LL Ow wLIJ 4 c70' 02aicL7 ill6:1; :01,=11 :Lij: ;Et IlLUCIzLittjj, : . :10:11j. 0;4 '' u- D o g < 00 I CD to — i" 0 (.? Ce 0 j.7. _., _. < LU 7.1 0 i- u_ LLI F- 0 I= I" 04 6- u7 1- z CD 17_ oa H Z CI- Ce 2 Z LIJ LLI C.) CI) 0 =, 0 0-J> ° 8' Z ti :: !! ; !!! ; :1 ; -- E- 03: """ pCOW 5 I- c73 Lu I-- :: ;u: Z 11 E5 „.., ;-1fT ii 2 65 LIL; !! !! 15J? .72' !! ;:i § g 0 Z w CO D 0 CI) Z 5 0 > R• eL Z ,LEI rzCe, Li 8 1- ijj 0_ 2 = < ca. ;0...,7%:u..i.u:z < - 5 co Lii 0 cc z 0 0 1-1-1 ° Z 9 Ea 0 g!:11C) ,011:!! ! !! E..1121J g ai 3: P: :) 1- f‘j --I LIJ Z .......uj CO 4 CI- 0 = CD Lii cr Tu ju j„„, f0=11_, i_ 00 0 1-- LU 44 -j :i LU 0 1..i.1 0 < ,, 0 > (Dam G! o.? ecet) Ocoo Wm. CC CL Lu LL,1 Lci - La LU Z 0 I" < ° __LLm-, Cl- 0 2 al P 0 Z I- 1 1 i L-j1 2 3 1.11 0 0 CC 0 0- 0 z CO I- U- uj = < I- 0 -I 2 LU LLI ce 0 -1 Z. - in c_ 0 < D z 10 <,..-.HZ0°C1-00 < 1.- L.J CO 2 Ce LL1 0 H4CZ : :L1,4 <0 ii...0 ICT2 >LU 1.--0 --I (J) - :1- H j: 1 w E5 LU I- 2 C° n: u- is a; •R z = a- CO CC u_ D P < co < CCC° 9 4: au:. 12 ow a.' 8 0 o ct ct 1- z`u 8 0 0) ""E 0 w ceoui.K,L F.- CI CO e-, 0O) 0 0 %--; ci. g z 1 0 t uu 1 (,) CC D: z<=, D0 z < 1._. Z— z' — i zc I nr ZLij 5ce F- = DCe LU 0 LL CO -7--- LL U- OZ1 - - - 02 i 61 U OZC 1 59 02' I- I< C .70-Z° 0 5 0 5 0 < 0 a c) 0 1.1.1 3: 0 ,..3 0 3: :3 0 0_ 0 0, 3: E- 0_ 0 0 ;3'6 m I__ 0 I- 0 CI WO CD I's C\1 N- CD IX 0 •;1' --I 1- 03 LL < WU: 0 0 CC 0 a- 0 0 CL- LL t° ,.: i- re = CL 0 1 c_11___CD4r_ce Ltil Luli <___cPi: tuj 1-<-62 z 0 2 _I E- rx m tr, c co z 3 Lr) >0- „,= rI D =-4 =-1 0> 0 WW XW MEO HO HO 0W . . I- 2 9Q) ‘- 0 2 2 cL. 2 0- 2' ce 14 U- CO ei_46_0 Q ,74- -±-=i c;.1 z_:: a ce o ce 0 w-' a 1. W CO E II f--C) CILU co03 zF-- 1_,C.2 uCL:12—LLCL1E7ctp—f_n_i__ LL LL. < 0 5 ce z z do, pec cece z LL1 --I LU 0 0 ) CC Z =.1 2 0 0 0 00 - LLZ ...1 I- 0 .- LU 0 .....u___ F- t3 '5 t3 2E CL .) D 1 co o :05 ci 1-. < D 2 LU UJ _c 1 Z Z 0 CO D D 0 IX W co 0 0 0 0 re F-< LU CI 0 CI ° C') LU LL Z 2 > •-- ix 1-7 r zz zz w 0 0> 0, 0 c) 0.11.1 00.1( 00 00 0 Lul- u Lo Ce 0 Z CL D 011 0 0 C.) 0 u.. > I- LJJ Z CL 1=.. ci En 2 2 2 2 u? 0 ±. 17_, 0 0 CZ') =I g -J: 00 0 0 0 ° 0 ° 0 _iiii •tt 0 P 2 cc 1.- -J >- 95 2 2 2 2 0 66 5 UJ ;J. LU Ul 0 C› • n: U.1 4( <O CD a 0 0 1- 1,_, 3: _i __I = • CO 7 (3 1-.• g.30 CI )Z Z H LO L° Lc) LO W 54.441 0 M 011 0 z 0? c? 0? c? z , , , = 0,) a 1-7Z 0 _.1 c4 = 6-1:-0- OS 07 2E LU P: E cri 9,1 ,- F- __, = Lu CL I-- Z Z.-30 0 ,,4 1.- ..._. — - u j an 1._ 0 g u j 0 L. .....- 0>Lu 00 >LLI 3 1 LLI > W Z ±: CI w C6 > 0 > a ,,, . , iii ,4- i- ,__ Ow CC) C --I OD_ 1-- :) U.1 5.7c1E om Om UJ .q.k 2 2 2 .2 u- l--' = a = 2 -.-1 2 < z cc Lu 0 D CC Lclej 0=_J ca< wo wo W ww0 wzi- 0 E- c0 0_ Ili 03, CC E- CC I-- CC 2E CL IA Z ‹C LLI 3: Z 111 U- m > 0 • 0 Ill 11- LL. cn uu co . to ci w 0 Cil CL z an Ill Z CL 1-- < CL > 0 CLZI.J.; 0 0 CC LL - ill 0 0 CIC uj 0 1- D > > LL 0- 5 -1 ce 'cow 0 CO L1.1 1- 0 c• i Ca O a; ca w LLI 0 LU 0 I- cc LU Nelii U./ ›- Lii Z 1-- 8 : Fccre.14111 ioTiLLI L LioLL= mu JIL oz :1 0 : jjc t Lis ..- 02 c lu ic e . .,. j. . . uj. i. , .0 ; c) _- z c°1-7 °/-11u2 reEpee _ozco Jo f 31 --0 osof L ztot1 - - Li 0; :7, . . . 1 1 i_li >_12 Ludi... 1:5., !tel._ to 80_ ocii= t: uu 5; 11J - %(111(7DD: 61") E3 00 cl w 40 c) 00 c) 0:rt=jdzz cn R. de 2 Z U- 4C ZZ 0W !! ZLUE1-5 !! 11 1! ?i il ]:. Col Lu Z CC LLI R ye, < 111 0: < uj ifS ."2.. 8 I-- =,, 2 ii c:l 8 g !4E' E. § 15 rill CS Cu re ..." ' 4C Sit J>LI 0 -Id g c) '12 ?-E g 2 8 2E 2 ./3, ti ' 2 7, :5 ',.! : :: :: < :: !!1-9, : ! 03 ,.... W ....1 07, E 22 :711 c) to LIS fj-j) 0 0 c) 07 Ea n: cL U6 L-1.11 Cil 0 O<W1-4EPO-ZWWfflYCI-1° ZgZC411(40LUZCCOI-C4=1= 2 z 0 in < oi_Luir....C)E12-J102 uj 0< Lg Z3 15 :2 v2 al 1 g t3 6 ! 2 2? zwzg..3.-QgpoEw—le5 z < = 5z 2E C) E2 2 g > g 8 00 R .J.L. LA. 0 Z _i I- 9 LU .- UJ u_ Ce 0 Cb' 0 Z Z 1.1.1 = 0 0 -I cni= . Z W LI., 66 Z Lu 0 LLJ Z CO co fiF cc 11.1 - 111 if) E- UJ u_ cC IJJ I.R LIU LU > z = CO all 0 z 0 = w Lu zb=a a) 5 w Ce LU A -.1 0_ ,, 5 z0 Lu < c3 <no< 111 Lu I-- cc 1-- = NI 0 00 LLI 7) Z CL = Lu 1_ 0 cc _ Ili ,z,..„, Lu s--,,___ cc 0 ..- en I r- L 0 00 10°06 Ji_ -1c1JC4m UJ < LU uj a_ -I 0 -.I CO_ c- c0=< 0I-I 0Z 0Zzuj LU CL - CC Li z EE C4 GC 03 :3 CO w m C) F- CC LIJ LIJ 0. 5 -J <0 CONTRACTOR SHALL TEST ALL CABLE THAT WILL BE REUSED. C FUTURE UPS BATTERY 5A CELLS 1 -240 r EX. 1/2 "W UP ND 1y'W OWN T BELOW RAISE FLOOR GENERAL NOTES: C.B. L EX. 16 "X12" BUS DUCT - 1 PANEL 'BPPB1" ❑ . ❑ - FUTURE BATTERY 5B DOCOINECT 480Vi DC, 1200A L__J t - : .,.• yam s �,.<..y, PANEL "BPPA1" 2. CABLE LADDER SIZE REPRESENTED IN FEET AND INCHES. 1 -0L INDICATES 12" WIDE CABLE LADDER. 3. CABLE LADDER INSTALLATION HEIGHT REPRESENTED IN FEET AND INCHES. (10 -0) REPRESENTS 10' -0" ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE CABLE LADDER. EXISTING EQUIPMENT ROOM HAS RAISED FLOOR AT 2' -3" HIGH. 4. ALL CABLE LADDER TO BE SOLID BAR, 2" STRINGER, PAINTED GRAY. 5. CONTRACTOR SHALL TEST ALL CABLE THAT WILL BE RE -USED. 1. EXISTING CONDITIONS NOTE: EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. ro r L 4 "x4" COLUMN (TYP. THIS ROOM) SPDB #1 EX. EXTERNAL +48V. RETURN BUS SPDE3 #1 MPDB R EC RE 2 F ru-RE LMOVALC)F -- E STING BATTERY F R INSTILL OI BATTERY 4AI CELLS1121 -240. 1 1 r SCALE: 1/4° = 1' -0" 1 RECOr. RECT. RECT. RECT. RECD._ _ _RECI aEcT RECT_ 4 6 8 10 FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A AGB- CRAG #27 DSB1 31,13,35 MB FUTURE UPS 4B 500 KVA POWER DOOM FUTURE UPS 5A 500 KVA CRAC #28 DSA1 25,27,29 MBP NOTIES INDICATED BY NUMBER IN 0: REFER TO SHEET DC -4 FOR CONTINUATION OF PDF FEEDER CONDUCTORS. XISTING (8 )-350 MCM ( -) CONDUCTORS FROM PDF 165 TO MPDB. (48 VDC.) XISTING (8) -350 MCM ( +) CONDUCTORS FROM PDF 165 TO EXTERNAL RETURN BUS, (48 VDC.) XISTING (8) -350 MCM ( -) CONDUCTORS FROM PDF 144 TO MPDB. (48 VDC.) XISTING (8) -350 MCM ( +) CONDUCTORS FROM PDF 144 TO EXTERNAL RETURN BUS, (48 VDC.) XISTING 1 -6L CABLE LADDER TRANSITIONS FROM 12' -1" TO 9' -1 ". STALL 2- 350MCM'S (THHN'S), 1 -3 /OGND. IN EACH OF (4) 2 -1/2" CONDUIT. REFER TO UPS 480V. C ONE LINE DIAGRAM SHEET DC -10. XISTING BUS DUCT BRACING SHALL NOT INTERFERE WITH NEW CABLE LADDER, MODIFY XISTING BUSDUCT BRACING AS NECESSARY. 0 NEW UPS 2B 500 KVA 0.9 PF MBP I • f« "r rrr r • FUTURE UPS 3A 500 KVA BRGB -1- EX. 1- 6L(9 -1) 1 DCGB -1 FGB -1 RECT. - -9-- RECT._ RECT 10 8 BATTERY 2B DISCONNECT 480V. D *, 120pA. REFER TO DC DRAWINGS. I 1 RECT. RECT. -7 - - -- y - EW 1 -6L(9- I 1 E E r>i ® a rittraiiiiNiirmossoinami � ii®i mmaiIliimli il ■ it nil ili l ill. 1n1111111011111111111111111111111111111111',, i 1�i11 , , t!i I . 1 10 - X. 1 -1) 6 I I 5 - E3Ff . 1_ RECT... _RECT. 6 4 2 `; 1st LAS ER E 3I BOX ---"/ RECT. I RECT. 3 - -j - - r - r p Q od MPDB 0 SPDB #1 PARTIAL FIRST FLOOR PLAN —POWER CABLE LADDER — POWER ROOM CONTRACTOR SHALL REMOVE EXISTING SPILL CONTAINMENT AND UNUSED TWO -TIER BATTERY RACK CURRENTLY ON SITE. CONTRACTOR SHALL REMOVE ACID ABSORBANT PILLOWS AS WELL. NEW 1- 6L(9 -1.) - SPDB #1 EX. 1- 6L(9 -1) EX. 1- 6L(9 -1) EX. BUS DUCT ELOq -ono � FUTURE BATTERY 3B DISCO•JNECI" 480V. DC,11;200A— I EXISTII STRIN 1 ROW, a Li T —EX. EXTERNAL 1 +48V. RETURN B(JS PANE;. I "CRPP 1" EXISTI$JG TE" . L RM PLANT #2 STRINU� #3 1 ROW, 2 TIER -24 BATTERY r G TERM. PLANT #2 #4 2 TIER 24 BATTERY 1M FUTURE UPS BATTERY 3A CELLS 1 -240 PANEL , -- PANEL - "BPPA2" L .. "BPPB2" L__...._..,.. PANEL "CI PPB1" Indicates future equipment to be installed. - Er Indicates Cable Ladder to be 11 11 11 11 11 11 11 11 11 11 removed. .IL. L._ DC CABLE LADDER SYMBOL LEGEND Heavy line indicates equipment face side. Indicates Existing Single Tier Cable Ladder. Indicates Existing Double Tier Cable Ladder. Indicates Existing Triple Tier Cable Ladder. Indicates New Cable Ladder to be installed. Indicates Water Fall (90° Outside Bend). REVIEWED FOR CODE COMPL gCE NFPA FEB 11 21109 . BUILDING RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Sheet No. co `i) k (IJ l LU *:K .qc‘ ci (c) ` V Fac. Code:TYKWWA 01 -05 -09 01 -15 -09 01 -26 -09 Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 DO -5 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - POWER ROOM EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY 1 EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER 24 BATTERY C FUTURE UPS BATTERY 5A CELLS 1 -240 r EX. 1/2 "W UP ND 1y'W OWN T BELOW RAISE FLOOR GENERAL NOTES: C.B. L EX. 16 "X12" BUS DUCT - 1 PANEL 'BPPB1" ❑ . ❑ - FUTURE BATTERY 5B DOCOINECT 480Vi DC, 1200A L__J t - : .,.• yam s �,.<..y, PANEL "BPPA1" 2. CABLE LADDER SIZE REPRESENTED IN FEET AND INCHES. 1 -0L INDICATES 12" WIDE CABLE LADDER. 3. CABLE LADDER INSTALLATION HEIGHT REPRESENTED IN FEET AND INCHES. (10 -0) REPRESENTS 10' -0" ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE CABLE LADDER. EXISTING EQUIPMENT ROOM HAS RAISED FLOOR AT 2' -3" HIGH. 4. ALL CABLE LADDER TO BE SOLID BAR, 2" STRINGER, PAINTED GRAY. 5. CONTRACTOR SHALL TEST ALL CABLE THAT WILL BE RE -USED. 1. EXISTING CONDITIONS NOTE: EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. ro r L 4 "x4" COLUMN (TYP. THIS ROOM) SPDB #1 EX. EXTERNAL +48V. RETURN BUS SPDE3 #1 MPDB R EC RE 2 F ru-RE LMOVALC)F -- E STING BATTERY F R INSTILL OI BATTERY 4AI CELLS1121 -240. 1 1 r SCALE: 1/4° = 1' -0" 1 RECOr. RECT. RECT. RECT. RECD._ _ _RECI aEcT RECT_ 4 6 8 10 FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A AGB- CRAG #27 DSB1 31,13,35 MB FUTURE UPS 4B 500 KVA POWER DOOM FUTURE UPS 5A 500 KVA CRAC #28 DSA1 25,27,29 MBP NOTIES INDICATED BY NUMBER IN 0: REFER TO SHEET DC -4 FOR CONTINUATION OF PDF FEEDER CONDUCTORS. XISTING (8 )-350 MCM ( -) CONDUCTORS FROM PDF 165 TO MPDB. (48 VDC.) XISTING (8) -350 MCM ( +) CONDUCTORS FROM PDF 165 TO EXTERNAL RETURN BUS, (48 VDC.) XISTING (8) -350 MCM ( -) CONDUCTORS FROM PDF 144 TO MPDB. (48 VDC.) XISTING (8) -350 MCM ( +) CONDUCTORS FROM PDF 144 TO EXTERNAL RETURN BUS, (48 VDC.) XISTING 1 -6L CABLE LADDER TRANSITIONS FROM 12' -1" TO 9' -1 ". STALL 2- 350MCM'S (THHN'S), 1 -3 /OGND. IN EACH OF (4) 2 -1/2" CONDUIT. REFER TO UPS 480V. C ONE LINE DIAGRAM SHEET DC -10. XISTING BUS DUCT BRACING SHALL NOT INTERFERE WITH NEW CABLE LADDER, MODIFY XISTING BUSDUCT BRACING AS NECESSARY. 0 NEW UPS 2B 500 KVA 0.9 PF MBP I • f« "r rrr r • FUTURE UPS 3A 500 KVA BRGB -1- EX. 1- 6L(9 -1) 1 DCGB -1 FGB -1 RECT. - -9-- RECT._ RECT 10 8 BATTERY 2B DISCONNECT 480V. D *, 120pA. REFER TO DC DRAWINGS. I 1 RECT. RECT. -7 - - -- y - EW 1 -6L(9- I 1 E E r>i ® a rittraiiiiNiirmossoinami � ii®i mmaiIliimli il ■ it nil ili l ill. 1n1111111011111111111111111111111111111111',, i 1�i11 , , t!i I . 1 10 - X. 1 -1) 6 I I 5 - E3Ff . 1_ RECT... _RECT. 6 4 2 `; 1st LAS ER E 3I BOX ---"/ RECT. I RECT. 3 - -j - - r - r p Q od MPDB 0 SPDB #1 PARTIAL FIRST FLOOR PLAN —POWER CABLE LADDER — POWER ROOM CONTRACTOR SHALL REMOVE EXISTING SPILL CONTAINMENT AND UNUSED TWO -TIER BATTERY RACK CURRENTLY ON SITE. CONTRACTOR SHALL REMOVE ACID ABSORBANT PILLOWS AS WELL. NEW 1- 6L(9 -1.) - SPDB #1 EX. 1- 6L(9 -1) EX. 1- 6L(9 -1) EX. BUS DUCT ELOq -ono � FUTURE BATTERY 3B DISCO•JNECI" 480V. DC,11;200A— I EXISTII STRIN 1 ROW, a Li T —EX. EXTERNAL 1 +48V. RETURN B(JS PANE;. I "CRPP 1" EXISTI$JG TE" . L RM PLANT #2 STRINU� #3 1 ROW, 2 TIER -24 BATTERY r G TERM. PLANT #2 #4 2 TIER 24 BATTERY 1M FUTURE UPS BATTERY 3A CELLS 1 -240 PANEL , -- PANEL - "BPPA2" L .. "BPPB2" L__...._..,.. PANEL "CI PPB1" Indicates future equipment to be installed. - Er Indicates Cable Ladder to be 11 11 11 11 11 11 11 11 11 11 removed. .IL. L._ DC CABLE LADDER SYMBOL LEGEND Heavy line indicates equipment face side. Indicates Existing Single Tier Cable Ladder. Indicates Existing Double Tier Cable Ladder. Indicates Existing Triple Tier Cable Ladder. Indicates New Cable Ladder to be installed. Indicates Water Fall (90° Outside Bend). REVIEWED FOR CODE COMPL gCE NFPA FEB 11 21109 . BUILDING RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Sheet No. co `i) k (IJ l LU *:K .qc‘ ci (c) ` V Fac. Code:TYKWWA 01 -05 -09 01 -15 -09 01 -26 -09 Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 DO -5 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - POWER ROOM 1 i r C FUTURE UPS BATTERY 5A CELLS 1 -240 r EX. 1/2 "W UP ND 1y'W OWN T BELOW RAISE FLOOR GENERAL NOTES: C.B. L EX. 16 "X12" BUS DUCT - 1 PANEL 'BPPB1" ❑ . ❑ - FUTURE BATTERY 5B DOCOINECT 480Vi DC, 1200A L__J t - : .,.• yam s �,.<..y, PANEL "BPPA1" 2. CABLE LADDER SIZE REPRESENTED IN FEET AND INCHES. 1 -0L INDICATES 12" WIDE CABLE LADDER. 3. CABLE LADDER INSTALLATION HEIGHT REPRESENTED IN FEET AND INCHES. (10 -0) REPRESENTS 10' -0" ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE CABLE LADDER. EXISTING EQUIPMENT ROOM HAS RAISED FLOOR AT 2' -3" HIGH. 4. ALL CABLE LADDER TO BE SOLID BAR, 2" STRINGER, PAINTED GRAY. 5. CONTRACTOR SHALL TEST ALL CABLE THAT WILL BE RE -USED. 1. EXISTING CONDITIONS NOTE: EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. ro r L 4 "x4" COLUMN (TYP. THIS ROOM) SPDB #1 EX. EXTERNAL +48V. RETURN BUS SPDE3 #1 MPDB R EC RE 2 F ru-RE LMOVALC)F -- E STING BATTERY F R INSTILL OI BATTERY 4AI CELLS1121 -240. 1 1 r SCALE: 1/4° = 1' -0" 1 RECOr. RECT. RECT. RECT. RECD._ _ _RECI aEcT RECT_ 4 6 8 10 FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A AGB- CRAG #27 DSB1 31,13,35 MB FUTURE UPS 4B 500 KVA POWER DOOM FUTURE UPS 5A 500 KVA CRAC #28 DSA1 25,27,29 MBP NOTIES INDICATED BY NUMBER IN 0: REFER TO SHEET DC -4 FOR CONTINUATION OF PDF FEEDER CONDUCTORS. XISTING (8 )-350 MCM ( -) CONDUCTORS FROM PDF 165 TO MPDB. (48 VDC.) XISTING (8) -350 MCM ( +) CONDUCTORS FROM PDF 165 TO EXTERNAL RETURN BUS, (48 VDC.) XISTING (8) -350 MCM ( -) CONDUCTORS FROM PDF 144 TO MPDB. (48 VDC.) XISTING (8) -350 MCM ( +) CONDUCTORS FROM PDF 144 TO EXTERNAL RETURN BUS, (48 VDC.) XISTING 1 -6L CABLE LADDER TRANSITIONS FROM 12' -1" TO 9' -1 ". STALL 2- 350MCM'S (THHN'S), 1 -3 /OGND. IN EACH OF (4) 2 -1/2" CONDUIT. REFER TO UPS 480V. C ONE LINE DIAGRAM SHEET DC -10. XISTING BUS DUCT BRACING SHALL NOT INTERFERE WITH NEW CABLE LADDER, MODIFY XISTING BUSDUCT BRACING AS NECESSARY. 0 NEW UPS 2B 500 KVA 0.9 PF MBP I • f« "r rrr r • FUTURE UPS 3A 500 KVA BRGB -1- EX. 1- 6L(9 -1) 1 DCGB -1 FGB -1 RECT. - -9-- RECT._ RECT 10 8 BATTERY 2B DISCONNECT 480V. D *, 120pA. REFER TO DC DRAWINGS. I 1 RECT. RECT. -7 - - -- y - EW 1 -6L(9- I 1 E E r>i ® a rittraiiiiNiirmossoinami � ii®i mmaiIliimli il ■ it nil ili l ill. 1n1111111011111111111111111111111111111111',, i 1�i11 , , t!i I . 1 10 - X. 1 -1) 6 I I 5 - E3Ff . 1_ RECT... _RECT. 6 4 2 `; 1st LAS ER E 3I BOX ---"/ RECT. I RECT. 3 - -j - - r - r p Q od MPDB 0 SPDB #1 PARTIAL FIRST FLOOR PLAN —POWER CABLE LADDER — POWER ROOM CONTRACTOR SHALL REMOVE EXISTING SPILL CONTAINMENT AND UNUSED TWO -TIER BATTERY RACK CURRENTLY ON SITE. CONTRACTOR SHALL REMOVE ACID ABSORBANT PILLOWS AS WELL. NEW 1- 6L(9 -1.) - SPDB #1 EX. 1- 6L(9 -1) EX. 1- 6L(9 -1) EX. BUS DUCT ELOq -ono � FUTURE BATTERY 3B DISCO•JNECI" 480V. DC,11;200A— I EXISTII STRIN 1 ROW, a Li T —EX. EXTERNAL 1 +48V. RETURN B(JS PANE;. I "CRPP 1" EXISTI$JG TE" . L RM PLANT #2 STRINU� #3 1 ROW, 2 TIER -24 BATTERY r G TERM. PLANT #2 #4 2 TIER 24 BATTERY 1M FUTURE UPS BATTERY 3A CELLS 1 -240 PANEL , -- PANEL - "BPPA2" L .. "BPPB2" L__...._..,.. PANEL "CI PPB1" Indicates future equipment to be installed. - Er Indicates Cable Ladder to be 11 11 11 11 11 11 11 11 11 11 removed. .IL. L._ DC CABLE LADDER SYMBOL LEGEND Heavy line indicates equipment face side. Indicates Existing Single Tier Cable Ladder. Indicates Existing Double Tier Cable Ladder. Indicates Existing Triple Tier Cable Ladder. Indicates New Cable Ladder to be installed. Indicates Water Fall (90° Outside Bend). REVIEWED FOR CODE COMPL gCE NFPA FEB 11 21109 . BUILDING RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Sheet No. co `i) k (IJ l LU *:K .qc‘ ci (c) ` V Fac. Code:TYKWWA 01 -05 -09 01 -15 -09 01 -26 -09 Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 DO -5 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - POWER ROOM 1 C FUTURE UPS BATTERY 5A CELLS 1 -240 r EX. 1/2 "W UP ND 1y'W OWN T BELOW RAISE FLOOR GENERAL NOTES: C.B. L EX. 16 "X12" BUS DUCT - 1 PANEL 'BPPB1" ❑ . ❑ - FUTURE BATTERY 5B DOCOINECT 480Vi DC, 1200A L__J t - : .,.• yam s �,.<..y, PANEL "BPPA1" 2. CABLE LADDER SIZE REPRESENTED IN FEET AND INCHES. 1 -0L INDICATES 12" WIDE CABLE LADDER. 3. CABLE LADDER INSTALLATION HEIGHT REPRESENTED IN FEET AND INCHES. (10 -0) REPRESENTS 10' -0" ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE CABLE LADDER. EXISTING EQUIPMENT ROOM HAS RAISED FLOOR AT 2' -3" HIGH. 4. ALL CABLE LADDER TO BE SOLID BAR, 2" STRINGER, PAINTED GRAY. 5. CONTRACTOR SHALL TEST ALL CABLE THAT WILL BE RE -USED. 1. EXISTING CONDITIONS NOTE: EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. ro r L 4 "x4" COLUMN (TYP. THIS ROOM) SPDB #1 EX. EXTERNAL +48V. RETURN BUS SPDE3 #1 MPDB R EC RE 2 F ru-RE LMOVALC)F -- E STING BATTERY F R INSTILL OI BATTERY 4AI CELLS1121 -240. 1 1 r SCALE: 1/4° = 1' -0" 1 RECOr. RECT. RECT. RECT. RECD._ _ _RECI aEcT RECT_ 4 6 8 10 FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A AGB- CRAG #27 DSB1 31,13,35 MB FUTURE UPS 4B 500 KVA POWER DOOM FUTURE UPS 5A 500 KVA CRAC #28 DSA1 25,27,29 MBP NOTIES INDICATED BY NUMBER IN 0: REFER TO SHEET DC -4 FOR CONTINUATION OF PDF FEEDER CONDUCTORS. XISTING (8 )-350 MCM ( -) CONDUCTORS FROM PDF 165 TO MPDB. (48 VDC.) XISTING (8) -350 MCM ( +) CONDUCTORS FROM PDF 165 TO EXTERNAL RETURN BUS, (48 VDC.) XISTING (8) -350 MCM ( -) CONDUCTORS FROM PDF 144 TO MPDB. (48 VDC.) XISTING (8) -350 MCM ( +) CONDUCTORS FROM PDF 144 TO EXTERNAL RETURN BUS, (48 VDC.) XISTING 1 -6L CABLE LADDER TRANSITIONS FROM 12' -1" TO 9' -1 ". STALL 2- 350MCM'S (THHN'S), 1 -3 /OGND. IN EACH OF (4) 2 -1/2" CONDUIT. REFER TO UPS 480V. C ONE LINE DIAGRAM SHEET DC -10. XISTING BUS DUCT BRACING SHALL NOT INTERFERE WITH NEW CABLE LADDER, MODIFY XISTING BUSDUCT BRACING AS NECESSARY. 0 NEW UPS 2B 500 KVA 0.9 PF MBP I • f« "r rrr r • FUTURE UPS 3A 500 KVA BRGB -1- EX. 1- 6L(9 -1) 1 DCGB -1 FGB -1 RECT. - -9-- RECT._ RECT 10 8 BATTERY 2B DISCONNECT 480V. D *, 120pA. REFER TO DC DRAWINGS. I 1 RECT. RECT. -7 - - -- y - EW 1 -6L(9- I 1 E E r>i ® a rittraiiiiNiirmossoinami � ii®i mmaiIliimli il ■ it nil ili l ill. 1n1111111011111111111111111111111111111111',, i 1�i11 , , t!i I . 1 10 - X. 1 -1) 6 I I 5 - E3Ff . 1_ RECT... _RECT. 6 4 2 `; 1st LAS ER E 3I BOX ---"/ RECT. I RECT. 3 - -j - - r - r p Q od MPDB 0 SPDB #1 PARTIAL FIRST FLOOR PLAN —POWER CABLE LADDER — POWER ROOM CONTRACTOR SHALL REMOVE EXISTING SPILL CONTAINMENT AND UNUSED TWO -TIER BATTERY RACK CURRENTLY ON SITE. CONTRACTOR SHALL REMOVE ACID ABSORBANT PILLOWS AS WELL. NEW 1- 6L(9 -1.) - SPDB #1 EX. 1- 6L(9 -1) EX. 1- 6L(9 -1) EX. BUS DUCT ELOq -ono � FUTURE BATTERY 3B DISCO•JNECI" 480V. DC,11;200A— I EXISTII STRIN 1 ROW, a Li T —EX. EXTERNAL 1 +48V. RETURN B(JS PANE;. I "CRPP 1" EXISTI$JG TE" . L RM PLANT #2 STRINU� #3 1 ROW, 2 TIER -24 BATTERY r G TERM. PLANT #2 #4 2 TIER 24 BATTERY 1M FUTURE UPS BATTERY 3A CELLS 1 -240 PANEL , -- PANEL - "BPPA2" L .. "BPPB2" L__...._..,.. PANEL "CI PPB1" Indicates future equipment to be installed. - Er Indicates Cable Ladder to be 11 11 11 11 11 11 11 11 11 11 removed. .IL. L._ DC CABLE LADDER SYMBOL LEGEND Heavy line indicates equipment face side. Indicates Existing Single Tier Cable Ladder. Indicates Existing Double Tier Cable Ladder. Indicates Existing Triple Tier Cable Ladder. Indicates New Cable Ladder to be installed. Indicates Water Fall (90° Outside Bend). REVIEWED FOR CODE COMPL gCE NFPA FEB 11 21109 . BUILDING RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Sheet No. co `i) k (IJ l LU *:K .qc‘ ci (c) ` V Fac. Code:TYKWWA 01 -05 -09 01 -15 -09 01 -26 -09 Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 DO -5 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - POWER ROOM Pil - 11 n 0 O ] JP L ILII : O 0 111 lE 1 0 - 1 ■■ ■■ Idle- .r ^I�rl ®I�s ^p •.J•. I t .Ykell'1a21tLLA.:[:.,1)i.iuktt J',tJ.,Ll ri.t.R:'.l.x., ',i: '.Yeifi - d'. via : M l,; rC•`t'.LSA „'.:u 4ti , n . , n1 +..T I f9T3 ,'tt1YC k 1 .02 144.03 144.04 144.05 144.06 144.07 144.08 144.09 144.10 NEW #2/0 LATERAL FRAME WORK GROUND ON GROUND LOOP AT BOTTOM TIER, TYP. EX. 1 -6L 9 -1 10 -7 i 1111. ® - .11..111111 - ._ 111 1 _. 11 ■111 , . ■ �, - 1/111111 / 1 - I - - I' y Vi!1,7V 7{, YiIIJVJ11Jr%J • - irlll ►til PiFJIIt,I r . iiv {4iJ ...An ��,,..r i•e.! 1 •�S � rrr ....,, , > .1.II�J 7i� .VJ! ri1kI�A1+ 571,1 ®�-. � r ..r. -r . r. l r r 1 }�Jl�wl�arar�!� � ll irr�.,ry ra r�J rra! � � ter, vs• Ir�►� r�Iv rs.t�l�l�a�rv� �s ✓s .,.•„rl..rr.,.... . i 'w.w.r •r�.I��, • rr rem.. ' w�aw • rrrsr�tl - �1 ✓•Ir i www . .sM wfom P - rl � r !,aw.mlr -n - n.ss, r .. � ! _ ' }t. M 1I ■I■ ■ „ IA' .1'1.1 1 I II I r�.esl r>>re. �.� r >ISrrr• .e, -1 MAIN FRAME WORK GROUND - EX. 1- 6L(9 -1 10 -7) EX. 1 -6L 9 -1 10 -7 (2 }TYP, �a R 1 m� 1 1 11111111111111 101111 I•) III RIM II IN I 7rII 1 II II I II II I 0 i lr"1 II II I II II I r II I II I > v EX. 1 - 6L 9 - 1 10 r 0 I II I I II I TYP. 0 r II I II I k- 4i & k' J Y4 C 4I 1 t1 d 1,, . •'I. >o ,a Kit NJ .* 'r dfr M1V. k I , " EX. 161(9 -1 10 7) 1 II y I / ' �a dr, I I I I I II II II I I II I I I I 1'4.11 0 1.!7- Y 4 VN ti tV3 U 6GFyy. yly } YY A "4 Y4f 4 , J ld AI is MJ i 4 1L'f 6G1 4:itl - ilii 11 ■, t ■ ■ � ; i, ul,� , � JI.1 kU. ■1111 11i ®111 1 1 1 ® 111 111 ►7o OrJ I�� ' fI11r1 G t»IFM r j 7 711�i 1� p0•YrA.•d f�/ l r rrAl'rw wrrwwArr It'* ylr. yr rw}w+w r / ' �rrlrrr. -r� rrr rrr .� W Ly. v I 0 NEW #2/0 LATERAL FRAME WORK GROUND TIER TYP. r t AT BOTTOM ND LOOP ON GROU 1 - EX. 1- 6L(9 -1, 10 -7) I ■i ■ ■■■II ■ ■ ■ ■11■ ■1■ ■111■ ■ ■■ ■■I ■1 ■1 ■■■■■ ■11111111111111.111111111 11111111111 £ � �I�r�r�t VMS e�rr1J �!�!s�.�. .....�.,r•rrl r_ I� _ r..a �r.I �,r - ��.L r a sar•,..,.r, ��,�..I�r, }..r ....,rte ^.__r r. ow Ir -rqr.. r.. , .. Th al-�ww. � , �� i r� l.+. r �r _ -- _ EX. 500 MCM MAIN FRAME WORK GROUND i I I I EX. 1 -L(9 -1, 10 -7) - - X111 1 dl1 _■ I■ 111■1 ■l ■ ■111■ I j I it 111 ■11 ■111■ ■ i N � 11 ■ 1 ■111■ II � _ 1 l llr 1 17E7 !•)Q.rJr r1� z� lA' r1/l IJ77111J17r..11J r a �1 r�� rr .rr . r .�r lral l .•r rr. . � •�!•�•Ir�arr�rara �I =BIM* a ►rrr r�lar►w a•� .r 1 r - _... _ � r�,lrr: -r• rrr rrr r I 1 .., 1 r r 1 ■ „ . EX. 1- 6L(9 -1, 10 -7) 1 ■■■■■ ■11■■■■ non ■1.111 ■■11 ■111 ■ ■ ■11■ ■1111 ■111 1■ � I m ais ■ 1 ■ ■ 1 ■ rll llJ ►/II►7 �L�i111JII7L#1.. �I� r,� �� v .rr, - +. } rte..- r.lr!}..w ,-mow. �- nr . � �„ . -r^ .ter I -. 0 111 111 1111111 I � , 11111 1 ■ 1■ 111■ $111.1■ ■1111 II 111111111 111111111 � .1 � I. � pR1V11rJI• �I71►1II►]•�IJ z1 aCa, RlllrJI��17 ,r.- ...-r.ar..r��Ir>r rr^e _rr- e- •lrrr> -rn.� r 'r ....r 1 rtlk'' NI ,F, It,'i rt'tl lr 11� VI!'..,W3 r.SN.dvto�YV.eS Lf.w• ,Sli :ede n i0,,v u 44.12 144.13 144.14 144.15 144.16 144.17 144.18 04 , I . . I II .! 0 7 11 I�II�ii III 1 II PDF 10. w i � 1 irr _sl t-•I ■1■ . _. _ .. Y.IFillriil^ 1.1.1 ti 1^ ir� � 1 Yril rein -� - r^ 1� 1111111111 iW w �i BM MATCHLINE REFER TO DC -7 FOR CONTINUATION EW(: JIPMEN �f' ELpoR II II I II II I it Tr `i 11 II I II II I 4 I I I i L , i i 1 1 . ... ®Ihl ire iwi i i 1ir*IIIIINir�ir�I�i �i il l U Nil NM I I II i 1IUIII11r�IIIII lU iiII..- I i i i� 1111 11 i� �I U GENERAL NOTES: 1. H -TAP CONNECTIONS ARE TO POINT TO THE GROUND SOURCE. 2. CONDUCTORS TO BE #6 AWG GREEN, UNLESS OTHERWISE INDICATED. 3. INSTALL GROUNDING STRAP ON ONE SIDE OF ALL CABLE LADDER JUNCTIONS. 5. ALL CABLE IS TO BE TYPE RHW /RHH TYPE, LOW SMOKE (LS)/ NON - HALOGENATED, GREEN COVERED, CLASS B STRANDING. ALL STRANDING IS TO BE TINNED TO HELP PREVENT OXIDATION. ALL CABLE MUST BE "UL LISTED" AND "CT RATED ". CABLE PROVIDED IS TO COME EQUIPPED WITH A GREEN OUTER COTTON BRAID COVERING. ®I■■ ■111 ■111.1 ■■MI ■■111 ■■11111111 ■11111 ■v1 ■111 1■ 11 ■ ■■ ■ ■1I ■■h■ •71) TlI • : ' r7 GWl�liii.�3S 'Jf!S,1Tid!�! Si'�S !r.ilii!7:�i �;_I:rd. l]!ru�. T J1111J1'1i.. ! �Si� lf•1.Ir�Ir.�.J1f�1!'lJl'�1 - y J1 la 7� �� tTr- f sl w l .r.lrrrl • •.rralrairs. rw sa!rs. w.. l��.rrr•Ir�.lrralr�ai ®.wi ■1.111■ I ■I■ 111 I l�l' , sh !!Sy...ad Lar 1 ... „.., .�. , . .. . , : v r.: '. . , , 1 ,Uf:t1A,✓ aku..,ul„dk'.r«� p. f, .. .. - . . .. v .t.. :. u1 e: v.k .:. ,4dlt'V 4. v. 4> . . , ...�.. e. ,.- .art r.,, , JblAi V' It, .t„ W.IG 4n. .! f,e e+Jl aUd':.,p. , r.,ra I. 41M ! . �r`� _r�lrrr rr �_rr�.rr r.ilirr�rrwnrir _rri iiiii! � -! _�� � I 1 l ii i rY rrY r_1 - _IlrrrlMU .... 11111 ■111 11111111 ■111■I■1■ 11111111111 -- ® --� EX. 1- 6L(9 -1, 10 -7) '11111 1 ; rl/ l 4. ALL AISLE GROUNDING CONDUCTORS ARE TO BE SUPPORTED FROM CABLE SUPPORTS, INSTALLED ON LOWEST CABLE LADDER; UNLESS OTHERWISE NOTED. A dCALE room 1 1 4 l I I t _ I r�anitilou Irai11� r_Ir_ Ir-r �- -.. - r -Ir_I�- lrlrrP r� �_ 1' 1111111/ ■■■ 1 111 I111111 1111111 I I ■ II I r 1 I , 10-7 EX. 1-6 1■ 5; Se w } Y.A ..r fl1 NI,GvI rP, ail ;CSM1 W... -: Y, u�- (=. N "1 ": EX. 1 -6 (9 -1, 10 -7) Iaf lI 4111111111111111111111111 i; IiI l i i 1: I _ . Al - as S,v V 7 }r ru .sr acv r W�Lw+ aar �>:.c �.': �:s aa� wms Ito -sit: . •,>,!- s,.i,'u �u:• a Ls al as •to ,i'a kit ruF pax c e -�i� ,r ndG- du4,y- J� t i w, ,u, sn ,t It r t o fi.F { .r ti: f:y,,.sd; I,.,rJ ., 1 'IS ! t):';:3 � t t.f.i ,.i.a E Vaa,:r ,1r t(.�.,�.t.�3 i .r,:r ,•4 F_.. k 7 ., E 1- 6L(9 -1, 10 -7) 1rIou rl^ rrr r^ rrrl_7 rl^ ®rrrlriri r-- - rr Ir _lll^I rrrlrirrnl rrr 1 IY•rr rrrlrrrl^ I Yrri l Yi ..r I- r_Ir•r mom i rrrl•rrllr -r 1 ' IIIIIIIIIIUIIII .� I 111. I> 1IIIIIIIIIIIIIII n. .1,' I a, S 4 ,.. j , t t . r .1`�,Yi 1 r. ., re ". air a .. ....... .. ' . "�. , . . :., :��: -- , on rxl » ci.,:',�:r rF:.xa, . ,M �d,•rs!r • a�e , , �r .,, . a niti r .9 t1. .n.. c:V. , t tr tJ ks! .5.• F • } 1 1 164.04 164.05 164.06 164.07 164.08 nc.r„x., "r, •.r, / ar An tif.aiilli Ll. nat:ii atlat iimaiika ir ,A3,Yk,gatil1,.r.kitiiaiiiy: iiLlika thult4:i1aMEixClNES Irrr , rrr rI_ rrr r1i_ wrA _. -rr ^ _.I ^ __ rr_ rlrl..w �IiIrr _ 1 ■11■ itilf ■11 ■11111 ■1 I it !I �1L'6 sli: �v YYw EX. 1- 6L(9 -1, 10 -7) EX. 1 10 - 7) EX. 1- 6L(9 -1, 10 -7) l .. rat v -r p •fit. ",a, dbtir ` tie A Lf I J 1 a, Ai11 a M1 AN -Al ikj_ I } ,117 ri if..: :Vain Viaisia.7-A5 ,]:tv III_rIr111Y � •^ lr I 111111■ - � ®I ®III 164.11 164.12 164.13 164.14 ' I I .tla IR','YIA'tt :. aU llSIA111 1,1 ,1vAl ; u:A AIECW,iV41:ill Gi :m cds t� - • r • Yu.'L3s�EU.,x 167.01 $Jt;n:and _ia L`v 167.02 167.03 1 tI v i . ll no Ana .'X%-'N 1Sr k �LL.SLIWJY.az.YliyLL ',L ,.1)yS" ;V„y 1A.u..vt4.i .. Y. v!\, 4n. ti2 .,i.44slti7.J.14,L.'3w.•41.w3,}. 1,1 ,., N 167.04 167.05 167.06 167.07 167.08 167.09 1 TIAL FIRST FLOOR PLAN - FRAMEWORK GROUNDING - SOUTH 1/4" = 1' -0" NOTES INDICATED BY NUMBER IN O: 1. CONTRACTOR SHALL REMOVE EXISTING FRAMEWORK GROUNDING AT POINT SHOWN TO ALLOW FOR INEW WALL CONSTRUCTION. 2. CONTRACTOR SHALL HAVE OPTION OF RE -USING EXISTING FRAMEWORK GROUNDING SHOWN TO BE REMOVED OR PROVIDING NEW CONDUCTORS FOR NEW WORK. IF CONDUCTOR IS RE -USED, THE CONTRACTOR SHALL INSPECT EXISTING GROUNDING CONDUCTOR FOR DEFECTS PRIOR TO INSTALLATION. 3. #6 AWG GREEN GROUNDING CONDUCTOR FROM PDF FRAME TO FRAMEWORK GROUNDING. GROUNDING CONDUCTOR SHALL FOLLOW POWER CABLE LADDER FROM PDF FRAME UNTIL GROUNDING CONDUCTOR IS TO HORIZONTAL CABLE LADDER. AT THIS POINT GROUNDING CONDUCTOR SHALL DROP DOWN TO LOWEST COMMUNICATIONS CABLE LADDER AND SPLICE WITH EXISTING #2 /0 AWG FRAMEWORK GROUNDING CONDUCTOR. 4. FURNISH AND INSTALL HEAT SHRINK END CAP. 5. CONTRACTOR SHALL REMOVE FRAMEWORK GROUNDING CONDUCTOR FROM PDF 42. CONTRACTOR SHALL REMOVE CONDUCTOR TO H -TAP CONNECTION. NEW BONDING JUMPER AS INDICATED. u DETAIL NOT TO SCALE t C) (-EXISTING RAISED FLOOR GROUND GRID BURNDY H -TAP COMPRESSION CONNECTOR OR APPROVED EQUAL. Jic,tvJ;. .,,t.4:14Y:i- t.Ueuk 67.10 167.11 167.12 167.13 167,14 167.15 167.16 167.17 , ;I ., t wn REFER TO DC -7 FOR CONTINUATION a. b 4 f I . R I .J 4 'i :I 4 w ,JL -rw i iS• ," te" • a 1, .. t� -,Y I. .. „ e » C4 ,. ELIYI EX. 1 -69 -1 10 -7 L ( } .. _.. ........ _ rrl rilrri^- . -__. _- . .,...... ._ _ _. .: ,,. ..:... � r�:.'r :aril - �f�r�rrrreiriAf� � �rrwf,_ i�rr_r� r.r rr.i iwlif._ �7!�f� �rr_rr -w - �7 r� �1 _ -_. _ !rl �i '° TY- f . -r^ � rsiTlm^ f. rr _� �Illr_ _. , I Ir� I I I I 1 I I i 1 I I i I i 11111 ! ! Ii jiiuHi I .. __ ' : .. iye ,.. w. i ;. I. v [kt4 , tlN,VUM!FV , r d d1 4...e{ dIW,4if21YAul dCYk! I ,. {,.}dE �. el1Y:CdtlSfklnLi , F. IJ !d rYi, I - YJfid ,lJe !L6,SR1M11 1, aWl4 lb.cLd: .IJPtEVYrt , dSr Y. diL,t0. LAli!l ulwdY , w • . p � A u ' i ... I _. 'Y fiirriYfr/ rrr l.r-Y. I rlli- 11filYll iiliY VIII l.rlli _I_ i� - i� rr �Ilfiil_ rrlP a rrr Ii11iY1 .rrr -�I - - rrY +i1ir1 -- - ifi1r1Y1•Irfii - - -_ - - r_II ^.rrr r' - rrr rrrlrrr rrr rrr -_ �. ri -1rrY � r-r IY_ ®Irawli -� I�I� .!R � ••� I �I �� 1 1111111 1 ■■I 1.1 11 111 1111111111_ I I _ 1 f 11111 1 I I 11111 I 11 111L 11111111 1111111 , 111111111111111 1 11111111Illlil - IIiIII I - 7) .�, EX. 1- 10 -EX. #2/0 LATERAL FRAME WORK GROUND ON GROUND LOOP AT BOTTOM TIER, TYP. D101 r -I INDICATES FUTURE EQUIPMENT L _ J TO BE INSTALLED. HEAVY LINE INDICATES EQUIPMENTFACE SIDE. INDICATES COPPER GROUND BUS. C3-- INDICATES HEAT SHRINK END CAP INDICATES H -TAP CONNECTION MATCHLINE VIEWED FOR COMPLIANCE Mp LYAIV CE NFPA 70 - NEC FEB 11 Nog QtY Tukwila INNS DRAWING SYMBOLS I RECEIVED CITY OF TUKW1LA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS - .ifiiiii1•1111._. N 2 3 4 Proj. Mgr.: KCM 01-15-09 01-26-09 02 -02 -09 Project No. WTA. 08093 Sheet NO. DC -6 PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUNDING - SOUTH II I PI vim 4,40441 EX. #2/0, H II 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 II II II 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I. 1 1 I 1 1 I N EVV SEC U RITY ROOM , !.• )1) 44 b W A! , i.!.. t , ) f I EX. 1-6L( 1, 10-7) 0 MIN nireai 0 1 .11 --I II II I ••••I IINAM• I !AA FLOOR 1 ii 0 0 0 II II I II u II II I II II I II II I ' I N II II I II II I ■•■•••••••• EX. 1-6L(9-1, 10-7) 0 I 1•VII 0 11 II II 1 II II I „as 4. 11111111111.111.1 RIEWAVAIVAIKIWAIMWAIWARVIIONIWAIN somas imprsim4w414-mui der 1 TYP. EX 1-6L( I I 1 I I • ••■•••••,,••••■ NEW #2/0 LATERAL FRAM WOR ON GROUND LOOP AT BO OM T 111111111111111111111111111111111111111111111411111111111111111111111111111111111111111 ■ u < D ‘ 1 4 !!../1/44,mota•Irl! 0 0 JAP AN" II EAV F II II II 11 II II II II II II II II II II Amir AM la fir 4W•I CAW An INA4A4 -. rags.; 1111 11111 I . PAR 4MIIPPIPANIZNIM 1:1W ivrIA= .../.1.14,W41VAVAIIAW tiVvablmfarOVAIND WM, W.W.IMMIIrmr.I 1 1 ; 1 i 1 1 1 1 1 , 1 ,'!,!1•;.64qt.t i :P.,/ 10 •7,lttl. ,..1l 22. a,/ ITT IA21,2' 2 , T 2..l, !i6t ithr i it ill! 'AO !)11 lilt 6 11 ! N!, Li). )),- lip !!! dr tic! !!,!!!II !1/1 l• .ir ,1 •21,, At Tl!, ,. - I! :Tr 12,,,leTtal Ti, 22 ,i 1,/l Ta! Ta- fqt 2•2I 4,;1 ) R,,,6A : TO 'at , ;a i!! TO Vil ):.,) i A Al' .j11113112PFAI61.• . MI L/ ■ Arlie 11 1 M 1121115 , 1 ! Is .4 Jj• mo lirArirMal a • / ixp. •• 21P1I 4.2, r I II I I II I I II I I II 1 1 1 1 ••• 0 II I II I TYP. 2 0 1, 10-7) ROUND R, TYP. C 1 r a 1, 10-7) 1••.'•1 ••,,! I . 1.„ "i I II: .t 14!! . , !!!! NINON =En Arm , -11111, 1 1 YAW V 1 JO II IA Hill Ilillill 0 MI NV 0 am. WPM -Mr Ana. I 4 - 4 J 4 ,4t 4 4, ' 7, 44 4,4 4 44. 4, !I III, vs!.1 441 4/ , 44, 4 , 4 4 , 4 4 • 4 EX4 MAIN AE I I WORK GROUND ;1. Arl ; ■ 11111111111[11111111111111111/1/111P1111111101/14 Itill1/111111114E1I'll111111 1111 V AIAVMMIN WIVAINIMMIAWWIWAV •••BIAIWAINLIII•MEIG•WIAMAI .MW VNVVAIN MVAW: WANSIMANI•IVIWAIVAINVAIRMAISIM•VAI.AMINWAV EMMY INIAM NWNAKINVIIII•W•1111,••••• MAI!". EX. 1-6 r 1, 10-7 11 . 1111111111111111111111111111111111111111111111111111111111111111111111111111111 111111111111111111111111111111 M Nvaff 1w1PW- ....xwmimparammummummi 2 PANI 1/04 IPM24;4112/2113111"/P104110042 111711V11 1,21111W.PRAWMOPIMPPM21/110A1 laP/420/110M24,5110111111MINI CIt2,1•205irammiro.a matimmEmiwa.uswarAnivirairmumummt.....A.,-+ Ell !+••11•••• ! ...........r...••••■■ .■■•■••:••••■•••••••••••••••••.• FRNA!........11.m....sagrA! •••■••••••••••••••■■•••••••••••••■■••••••■•••••••• •••■ ••••.!1!.•••••••■• vo,•1•••••■• ••••••• •NMI Mr 111.1,■•••■•■••110•11.,NIII.M.1.14/INNBONNIA. W.A.,. I MIAINNIA ll.inprial■AICAA rawv•nrammv■•••••••■ MA. W4■ ....I.. ••■•■•• P.m. !!,....1......:.... ......w...........1.... ,..• t).! IN M kisi 9444 tx vat g 11 .:1)!X ali!-X.Zg :711.! tX2 Y il •We 3S 47X.,4±, 5X1 12 )1 44 9:1 ,c.x4X2' UT /111 v11 a 4,ii d) • o 1 IN ,tr.6 go, *14} t!E.1 :Al , is* u VA! 411,-IV .A..1.154■T 1 eTITI 2,71- tlaTI U,Ta A l 221 l 421 , 10. l'Tl Olti..TTT ITTTgil VI lal Al 121. Xi:, Li'i I I ! 1 1 I I [ L.; ; k.ili; ! 1 I I 1 i 1 1 I I I 1 x'72 MANMW./MI/d/M11/1M M '1 IMMIPM :111/2/11/M NUMWM,MMIUMMIRIMMMMIIMMUIPARIMMMLiM/AMIA WARM/ 11/1WAMMIIM/21/M2IMMOVAMMUIIMIWZOMMILIMIUMMIM21/410 MAI 2111MIMMOMMI/11 "AMMIAMMIII 1-6 MIMFIRMAMIA1/214""1 ‘11111111111111111111111111111111111111111111111111111111111111 1111 11111141111111111 i 11111111111111111111111111111111111111111111ff IMP a /2 9 1, 10-7) MUM ii 1 Ii 0 MUM III 111111 III 1111111111 11111111111 HI I II II I II 11 I EX. 500 MCM sz !WiNVas'Av . Api 73K-2 I I 11 II II II II II II 1 1 11 II II II II II II II II ,pojw! /417774177 u u NEW 0-6L(9-1) NEW 48" AGB-2 Holm 11■1 • s 't 1.;..1 1 II EX. 1-6L 9-1 10-7 1 &TM I, MID Nit Saxe Xx 2 X 11111111d • xX2 12.X.X2 - 16 I liar NMI -1 mime !ARAM FUTURE PANEL "DP4 MATCHLINE IDCGB 1 170 MMMMM M PPP I. AGB-1 I I I _ I BRGB-1_ I I I . _ - ; 5. ALL CABLE IS TO BE TYPE RHW/RHH TYPE, LOW SMOKE (LS)/ NON-HALOGENATED, GREEN COVERED, CLASS B STRANDING. ALL STRANDING IS TO BE TINNED TO HELP PREVENT OXIDATION. ALL CABLE MUST BE "UL LISTED" AND "CT RATED". CABLE PROVIDED IS TO COME EQUIPPED WITH A GREEN OUTER COTTON BRAID COVERING. REFER TO DC-6 FOR CONTINUATION GENERAL NOTES: 1. H-TAP CONNECTIONS ARE TO POINT TO THE GROUND SOURCE. 2. CONDUCTORS TO BE #6 AWG GREEN, UNLESS OTHERWISE INDICATED. 3. INSTALL GROUNDING STRAP ON ONE SIDE OF ALL CABLE LADDER JUNCTIONS. 4. ALL AISLE GROUNDING CONDUCTORS ARE TO BE SUPPORTED FROM CABLE SUPPORTS, INSTALLED ON LOWEST CABLE LADDER; UNLESS OTHERWISE NOTED. DCGB-1 FUTURE PANEL " SCALE: 1/4" P3A" I. 1111111111111111 NEW PAN ELBOARD ALASER NE 3 BOX I I -___ ____ PANEL "CRPPA1" ft 41: D 0 MIA II all IIII 11 1111 111 1111 1111 111 1111 III III II III 111 II a II II IFNI IIII 1111 III II II I 1111 II II 11 111 1111 IIIIII I II II I 1111 14 111 E . 1-6 9-1 10-7 IL I. Laadliar. Laud/ama c:j; 10 7 'Mg ;71 . 4iii iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiiiiiiiiiii rl,-.1911:10.901.=?I ' LVrtM112:,==:i21 V.r.,M721Mer.:=IMI.= ! sm.v.tri mmi 9- = 2. 3113:11Etin 22.1521.212A,MILTIrli .ff11 EX. 1-6L( 1, 10-7) 1, P !,..- ,,,i r; ?\ , i !I:: .1. '.1,) iv■,:r; ! 1 1 1 1 i 1 I l I : in I a!:14 ':I ilr il, 1 .:, a ., 141: iiI■1 1 ,1, , ,12 iiii 1.1: .), I rar!Ilo 5.•• 141 ..thl ,,,, ,al T.1. ■q .ua s, ,k. , , ,'".. -):' ■ ' . 4 " , I * I D 0 mivei mom ••■•.1 natal i i ■ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _ l ......... • • alai I I-- G;LIM 'ir-r .. or.. 1 rAMI - M 2 .1= 1 . 1 3 12111 , 5 91F11, 1 74 A liP21 9 1FM21 , 21 . ■! 1, .1. .1/ . .AI ../ I .. .1.' • ..■...1.../■1•••=.. ' •-.2,...,..02,111.1i I i 1 441 malt 1, S! 1 13' s ii,1 - 4.! !!re .2 I ,•'• -tiC! !! 1Tilli Tfi 11 '.1.111limmor ',4■,24,..444Lsms!),mv.ennlir.4.4iMmidomlopowssi.IFFAIR.w.A.4.4.11.172,.......41MI,OPTIr■,111IIN.A1■IMIamvee2 Ikkurov N... =••••11••••■11.!••••1•••■•1•■••••1,!■!,.11Avill•••■1.•••467 MOW E . 1-6L NOTES INDICATED BY NUMBER IN 0: 1. CONTRACTOR SHALL REMOVE EXISTING FRAMEWORK GROUNDING AT POINT SHOWN TO ALLOW FOR NEW WALL CONSTRUCTION. 2. CONTRACTOR SHALL HAVE OPTION OF RE-USING EXISTING FRAMEWORK GROUNDING SHOWN TO BE REMOVED OR PROVIDING NEW CONDUCTORS FOR NEW WORK. IF CONDUCTOR IS RE-USED, THE CONTRACTOR SHALL INSPECT EXISTING GROUNDING CONDUCTOR FOR DEFECTS PRIOR TO INSTALLATION. 3 RELOCATED EXISTING 500 MCM GROUNDING CONDUCTOR FROM EXISTING AGB-1 TO NEW AGB-2. CONTRACTOR SHALL ENSURE PLENTY OF LENGTH IS LEFT ON CONDUCTOR TO COMPLETE RELOCATION OF LINE. 4. FURNISH AND INSTALL HEAT SHRINK END CAP. 5. CONTRACTOR SHALL REMOVE FRAMEWORK GROUNDING CONDUCTOR FROM EXISTING AND REMOVED PDF'S 68,70, AND 72. CONTRACTOR SHALL REMOVE CONDUCTOR TO H-TAP CONNECTION. 1 LJv EX. 1-6L(9-1, 10-7) 1'7 011 PANEL "BPPA2" PANEL "CRPPB1" i,• EX. 1-6L(9-1, 10-7) ' 7 -- 7, 1 PANEL BPPB2 1 - - • y uy • EX. I PDF 72 I 1 I r ' I si ie.! i II 211 al I- WA tlt, • - EX. I PDF 70 I 111111111 \;\ a at rad al ita ird ?Ai 1 1 L. 1 . 1) I..I 1 1.. PART! L 1.I9ST FLOOR PLAN - FRAMEWORK GROUNDING - NORTH E 1 . 7"01311:1V14 , 111 ROOM XFMR PANEL UTRL14:: "ULPP1-1" EX 1-6L(9-1, 10-7) ANALASER I ZONE 4 BO* • r 4 1 1 . 1 '0,1; llul-42/12tr lIll!!e2tral.112:T!r ;IR 2:1-9!)-Xe..+12,12f6 ! ! ! ! X i -4.11 22t ) 2 X F , X X , . - W 9U .1D Ali !KO •:;! .12,[22,2x1 .4X2 - . .0• a, /I !),"1 VI XI, pr. VT, 2'2 I 5 OA I "1 (43.I.gi 7.6.10 . 1 . 2 1 ) - ..!', '11 I . I :1 :1(0 r.:1 EX. MMO -6L 9- , 10-7 i 1111 111111111111 EX. 1-6L 9-1, 10-7 EX. 1-6L 9-1, 10-7 wa 222-X .141ix-iix1-141-X12,2111-1X111`21 Z13) 1 &Id X "6 I.), EX. 1-6L(9-1, 10-7 BATTERY 1D BATTERY 1C BATTERY 1B i EX. 1-6L(9-1, 10-7) 1 tl-A2X-XX1121."),IIHJ !..42 XXX! -21t .21X 2.21-41,x&X! XXXX -2:2•Wi-ail!"1"4.221121 224 ) 20.1. 12, 12." 22'..X•225.12,1' XiX'XIX2.122-Y2t.1.-1X5 eza .14ti ;121-111) L Ii ;IA 1-2.0 !hil" - 411.14 i lI 242 " ;A a 4,4, WA tSI Ca!, !HIT-XXX-iXtx 23.121 )Z2.221 - 171.11.'71 '175.02 176.03 175.0 - 1751.1 1,I 1715 r2f.i 1'75 07 '17508 175. 175.10 '175 11 175 12 '175 1 t7. 1 IlL t 7.!.. .......... ...... _ EX. 1-6L 9-1, 10-7 1111111111111111 1111 1 1111 II 1111111111 I II , ., ,, I. ., t .,, 2 • ...,./..- .?-eal 1), .1 i! i,...1! :IA 421X- XS/ 1 X1 Itt all XXX! X 2-!IXItx-¢11 214 iii- i ' la.l. lET-1.12 41 l Ilil ii.la Al i -l!th•Lier- I I I I I EX. #2/0 LATERAL FRAME WORK GROUND ON GROUND LOOP AT BOTTOM TIER, TYP X!, 21 -lilT-2/11 :11!S al ,tv 051 LITUTTITTIlt.41T-2 -T11.421,211 ill!T tie • T .1114-rA-M-ele Ithed-Z el zit ;SO 14,1 .!XX14XXxlit !XXI 0.01-44-0 va. 01-22i-KA)W, La! I i S!tix3.22X-21.1-21-t" 1 17 173 02 '173. LI 17 a 04 173.05 173.00 172.07 173.02 - 173..09 '1,3.10 1 73.11 17 3.12 '173 '13 173.14 1 1 1 1 0 ',...1, . ...\ "■■ ..!, \ t P.. , t ., ... ., . ... (0: , 'di tIN! .!..7 !AI. ",:! INT kx X il IA .2 1 ,11 4 1 a .,. ,, -le -2. XXX UT EU .8a Kt, Ull-UF-ITJETC-Ter Till- L 2 S kr.. •.. 'XXI x '1,1 X.... XXI a-I I LA1:I ,. -I` . .1.4 do T 2. 4 . N. . l , Till .4! 22 !lb/ Li s 4,1 ., ,, ..,...-4. , , - _I -,,,,5 r., , .01 ;I: -,. . , i, . . 41. .. , .L ii t„. • , L . ., Ar. . , r I I ! 1 EX. 1-6L 9-1, 10-7 NINIUMUNIIIMUMNIMUIN -,, REFER TO DC-6 FOR CONTINUATION ( ..... E1.09 BA TTERY 1A UPS-1 010 1■MI .■■• REVIEWED FOR CODE COMPLIAN( NFPA 70 - NEC FEB 1 1 2003 .1.4 !■M! WIN DRAWING SYMBOLS ✓ - 1 INDICATES FUTURE EQUIPMENT L J TO BE INSTALLED. HEAVY LINE INDICATES EQUIPMENTFACE SIDE. 77 INDICATES COPPER GROUND BUS. INDICATES HEAT SHRINK END CAP INDICATES H-TAP CONNECTION ( 1 RECEIVED CITY OF TUKW1LA FEB 0 5 2009 PERMIT CENTER "111=111MMOPI■01011111•11W c z LLI 3 2 3 4 01-05-09 01-15-09 o et• o o mo w v a il • 0+ Z EN(' CO In 41: im d z < W 6N O 5W -2Wtt > JIB 0 <E1 Project No. WTA. 08093 Sheet No. Fac. Code:TYKWWA Drawn By: IM, PS, LI Designed By: KCM, DL, Z Proj. Mgr.: KONA Date: 12-12-08 Revision 100% CD 01-26-09 ADD. NO. 1 02 PERMIT SET 95% REVIEW DC-7 VVTA - 08093 PARTIAL FIRST FLOOR PLAN COPYRIGHT 0 2009 FRAMEWORK GROUNDING WTA, INC. NORTH CONSULTING ENGINEERS ABILENE, TEXAS EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER 24 BATTERY FUTURE UPS BATTERY 5A CELLS 1 -240 EX. 1I W UP A ND 1 "W OWN T Ci BELOW RAISED FLOOR ❑ EX. 16"X12" BUS DUCT-- FUTURE BATTERY 5B DOCOF% NECT -- 480V 1200A L__ " BPPA' 1 ' �1_ 4 "x4" COLUMN (TYP. THIS ROOM) 3. INSTALL GROUNDING STRAP ON ONE SIDE OF ALL C JUNCTIONS. 5. ALL CABLE IS TO BE TYPE RHW /RHH TYPE, LOW SMO NON - HALOGENATED, GREEN COVERED, CLASS B ST STRANDING IS TO BE TINNED TO HELP PREVENT OXI MUST BE "UL LISTED" AND "CT RATED ". CABLE PROVI EQUIPPED WITH A GREEN OUTER COTTON BRAID CO 6. EXISTING GROUNDING FOR ALL RECTIFIERS, MPDB'S REMAIN. BLE R EC 1 2 GENERAL NOTES: 1. H -TAP CONNECTIONS ARE TO POINT TO THE GROUN u SOU 2, CONDUCTORS TO BE #6 AWG GREEN, UNLESS OTHERWIS 4. ALL AISLE GROUNDING CONDUCTORS ARE TO BE SU POR CABLE SUPPORTS, INSTALLED ON LOWEST CABLE DDE OTHERWISE NOTED. E (L NDI ATIO ED I ( ERIN AND UTURER OF X ISTING 1 48V. BATTERY O R INST,LL 0 BATTERY A CELLSI121 -240. I I I I r RECT. RECT. - 5 — RECD "L _. 4 r1 CE. NDICATED. DDER ED FROM POWER UNLESS -. ALL I ALL CABLE 0 COME LL SPDB'S SHALL RECT. UTURE FUTURE 'ANEL "DP5A PANEL! "DP4B' SCALE: 1/4" =1' -0" J FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A CRAC #27 DSB1 31,23,35 POWER R1J OIVI FUTURE UPS 5A 500 KVA ;Hrrr irrr�rrr ' ± CRAC #28 DSA'I 25,27,29 ❑ BRGB - 1 ❑ NEW UPS 2B 500 KVA 0.9 PF MBP r. FUTURE UPS 3A 500 KVA KU! r r+trrr rr+jsur�arrr EX. #2/0 LATERAL GROUND -- 'A1 au4 ivt tal :615 4A id5 'S3 G7f E8 ,-j u4 all I' tau uc7 1513 uC iiYl 515 73.1 Nul A70 7ik3 3911 1319 341 5mi G 331 %s7 LIU did 8i C5 30 1410 i lal 3333 3P7 5su iifl 1147 r@a G5i W5 NU GA E3 1339 1337 7r7 i'aC 334 349 411 +31 a" 44 MI v& . Sid rah am ¢N7 39I 1 1M 3331 4$7 4:8 NOTES INDICATED BY NUMBER IN 0: 1. FURNISH AND INSTALL HEAT SHRINK END CAP. 2. CONTINUATION OF EXISTING #2/0 GROUND BUS CONDUCTOR FROM DCGB -1. I II N i b 11q� X 114111 I ECT. RECT. T - 5p1 B #1 DCGB -1 FGB -1 1E)ATTERY.RACK _ _ _ ._ _ _BATTERY _RACK RECT. 7 . NEW #6 GND. FOR NEW #8 GND. FOR BATTERY 2B DISCONNECT 480V. 1 120PA REFER TO DC DRAWINGS. I I I I I I RECT RECT. _ _ — RECT RECT RECT. _ LA ER E 3 BOX I NEW PANELIBOARD MPDB LI "DP214" I � ❑ PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUNDING -POWER ROOM — - SPDB #1 'ND. FOR Y RACK 1 I F LI I^J PANE. "CRPPAI" T J FUTURE BATTERY 38 DISCONNECT" 480V. DC, 11200A I __ J EXISTI STRIN 1 ROW, EXISTI STRIN 1 ROW #3 2 TIER -24 BATTERY G TERM. PLANT #2 2 TIER -24 BATTERY BATTERY r FUTURE UPS BATTERY 3A CELLS 1 -240 i :L a_-- ---- _____________ — - - - - -- PANEL "CP,PPB1" PANEL , "BPPB2" - - 'I_....___._....._.. _. .1t r 1 INDICATES FUTURE EQUIPMENT L _ i TO BE INSTALLED. ( H- DRAWING SYMBOLS HEAVY LINE INDICATES EQUIPMENTFACE SIDE. 'I'r INDICATES COPPER GROUND BUS. INDICATES HEAT SHRINK END CAP INDICATES H -TAP CONNECTION ELO9 L._ EVIEWED FOR E COMPLIANCE NFPA 70 - NEC FEB 11 2009 Tukwila ILaY DIVISIL RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 II 0 t ots 0 mO M w in I- U' N w II1 ,pwLL is w�O w i 3 Z > ▪ W j so w ,n' ZmN O <12 wz co (0 (I) ( D (i) Lu co Drawn By: IM, PS, ZJ Fac. Code :TYKWWA r1 Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 95% REVIEW 1;00% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 Sheet No. DC PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUNDING - POWER ROOM EXISTING TERM. PLANT #2 - STRING #2 ROW, 2 TIER-24 BATTERY STRING #4. 2 ROW, 2 TIER-24 BATTERY BATTF L EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER 24 BATTERY FUTURE UPS BATTERY 5A CELLS 1 -240 EX. 1I W UP A ND 1 "W OWN T Ci BELOW RAISED FLOOR ❑ EX. 16"X12" BUS DUCT-- FUTURE BATTERY 5B DOCOF% NECT -- 480V 1200A L__ " BPPA' 1 ' �1_ 4 "x4" COLUMN (TYP. THIS ROOM) 3. INSTALL GROUNDING STRAP ON ONE SIDE OF ALL C JUNCTIONS. 5. ALL CABLE IS TO BE TYPE RHW /RHH TYPE, LOW SMO NON - HALOGENATED, GREEN COVERED, CLASS B ST STRANDING IS TO BE TINNED TO HELP PREVENT OXI MUST BE "UL LISTED" AND "CT RATED ". CABLE PROVI EQUIPPED WITH A GREEN OUTER COTTON BRAID CO 6. EXISTING GROUNDING FOR ALL RECTIFIERS, MPDB'S REMAIN. BLE R EC 1 2 GENERAL NOTES: 1. H -TAP CONNECTIONS ARE TO POINT TO THE GROUN u SOU 2, CONDUCTORS TO BE #6 AWG GREEN, UNLESS OTHERWIS 4. ALL AISLE GROUNDING CONDUCTORS ARE TO BE SU POR CABLE SUPPORTS, INSTALLED ON LOWEST CABLE DDE OTHERWISE NOTED. E (L NDI ATIO ED I ( ERIN AND UTURER OF X ISTING 1 48V. BATTERY O R INST,LL 0 BATTERY A CELLSI121 -240. I I I I r RECT. RECT. - 5 — RECD "L _. 4 r1 CE. NDICATED. DDER ED FROM POWER UNLESS -. ALL I ALL CABLE 0 COME LL SPDB'S SHALL RECT. UTURE FUTURE 'ANEL "DP5A PANEL! "DP4B' SCALE: 1/4" =1' -0" J FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A CRAC #27 DSB1 31,23,35 POWER R1J OIVI FUTURE UPS 5A 500 KVA ;Hrrr irrr�rrr ' ± CRAC #28 DSA'I 25,27,29 ❑ BRGB - 1 ❑ NEW UPS 2B 500 KVA 0.9 PF MBP r. FUTURE UPS 3A 500 KVA KU! r r+trrr rr+jsur�arrr EX. #2/0 LATERAL GROUND -- 'A1 au4 ivt tal :615 4A id5 'S3 G7f E8 ,-j u4 all I' tau uc7 1513 uC iiYl 515 73.1 Nul A70 7ik3 3911 1319 341 5mi G 331 %s7 LIU did 8i C5 30 1410 i lal 3333 3P7 5su iifl 1147 r@a G5i W5 NU GA E3 1339 1337 7r7 i'aC 334 349 411 +31 a" 44 MI v& . Sid rah am ¢N7 39I 1 1M 3331 4$7 4:8 NOTES INDICATED BY NUMBER IN 0: 1. FURNISH AND INSTALL HEAT SHRINK END CAP. 2. CONTINUATION OF EXISTING #2/0 GROUND BUS CONDUCTOR FROM DCGB -1. I II N i b 11q� X 114111 I ECT. RECT. T - 5p1 B #1 DCGB -1 FGB -1 1E)ATTERY.RACK _ _ _ ._ _ _BATTERY _RACK RECT. 7 . NEW #6 GND. FOR NEW #8 GND. FOR BATTERY 2B DISCONNECT 480V. 1 120PA REFER TO DC DRAWINGS. I I I I I I RECT RECT. _ _ — RECT RECT RECT. _ LA ER E 3 BOX I NEW PANELIBOARD MPDB LI "DP214" I � ❑ PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUNDING -POWER ROOM — - SPDB #1 'ND. FOR Y RACK 1 I F LI I^J PANE. "CRPPAI" T J FUTURE BATTERY 38 DISCONNECT" 480V. DC, 11200A I __ J EXISTI STRIN 1 ROW, EXISTI STRIN 1 ROW #3 2 TIER -24 BATTERY G TERM. PLANT #2 2 TIER -24 BATTERY BATTERY r FUTURE UPS BATTERY 3A CELLS 1 -240 i :L a_-- ---- _____________ — - - - - -- PANEL "CP,PPB1" PANEL , "BPPB2" - - 'I_....___._....._.. _. .1t r 1 INDICATES FUTURE EQUIPMENT L _ i TO BE INSTALLED. ( H- DRAWING SYMBOLS HEAVY LINE INDICATES EQUIPMENTFACE SIDE. 'I'r INDICATES COPPER GROUND BUS. INDICATES HEAT SHRINK END CAP INDICATES H -TAP CONNECTION ELO9 L._ EVIEWED FOR E COMPLIANCE NFPA 70 - NEC FEB 11 2009 Tukwila ILaY DIVISIL RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 II 0 t ots 0 mO M w in I- U' N w II1 ,pwLL is w�O w i 3 Z > ▪ W j so w ,n' ZmN O <12 wz co (0 (I) ( D (i) Lu co Drawn By: IM, PS, ZJ Fac. Code :TYKWWA r1 Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 95% REVIEW 1;00% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 Sheet No. DC PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUNDING - POWER ROOM EXISTING TERM. PLANT #2 - STRING #2 ROW, 2 TIER-24 BATTERY EX. #1 BATTF EX. TERM. PLANT #1 STRING #1 1 ROW, 2 TIER -24 BATTERY EX. TERM. PLANT #1 STRING #2 1 ROW, 2 TIER 24 BATTERY FUTURE UPS BATTERY 5A CELLS 1 -240 EX. 1I W UP A ND 1 "W OWN T Ci BELOW RAISED FLOOR ❑ EX. 16"X12" BUS DUCT-- FUTURE BATTERY 5B DOCOF% NECT -- 480V 1200A L__ " BPPA' 1 ' �1_ 4 "x4" COLUMN (TYP. THIS ROOM) 3. INSTALL GROUNDING STRAP ON ONE SIDE OF ALL C JUNCTIONS. 5. ALL CABLE IS TO BE TYPE RHW /RHH TYPE, LOW SMO NON - HALOGENATED, GREEN COVERED, CLASS B ST STRANDING IS TO BE TINNED TO HELP PREVENT OXI MUST BE "UL LISTED" AND "CT RATED ". CABLE PROVI EQUIPPED WITH A GREEN OUTER COTTON BRAID CO 6. EXISTING GROUNDING FOR ALL RECTIFIERS, MPDB'S REMAIN. BLE R EC 1 2 GENERAL NOTES: 1. H -TAP CONNECTIONS ARE TO POINT TO THE GROUN u SOU 2, CONDUCTORS TO BE #6 AWG GREEN, UNLESS OTHERWIS 4. ALL AISLE GROUNDING CONDUCTORS ARE TO BE SU POR CABLE SUPPORTS, INSTALLED ON LOWEST CABLE DDE OTHERWISE NOTED. E (L NDI ATIO ED I ( ERIN AND UTURER OF X ISTING 1 48V. BATTERY O R INST,LL 0 BATTERY A CELLSI121 -240. I I I I r RECT. RECT. - 5 — RECD "L _. 4 r1 CE. NDICATED. DDER ED FROM POWER UNLESS -. ALL I ALL CABLE 0 COME LL SPDB'S SHALL RECT. UTURE FUTURE 'ANEL "DP5A PANEL! "DP4B' SCALE: 1/4" =1' -0" J FUTURE BATTERY 4A DISCONNECT 480V. DC, 1200A CRAC #27 DSB1 31,23,35 POWER R1J OIVI FUTURE UPS 5A 500 KVA ;Hrrr irrr�rrr ' ± CRAC #28 DSA'I 25,27,29 ❑ BRGB - 1 ❑ NEW UPS 2B 500 KVA 0.9 PF MBP r. FUTURE UPS 3A 500 KVA KU! r r+trrr rr+jsur�arrr EX. #2/0 LATERAL GROUND -- 'A1 au4 ivt tal :615 4A id5 'S3 G7f E8 ,-j u4 all I' tau uc7 1513 uC iiYl 515 73.1 Nul A70 7ik3 3911 1319 341 5mi G 331 %s7 LIU did 8i C5 30 1410 i lal 3333 3P7 5su iifl 1147 r@a G5i W5 NU GA E3 1339 1337 7r7 i'aC 334 349 411 +31 a" 44 MI v& . Sid rah am ¢N7 39I 1 1M 3331 4$7 4:8 NOTES INDICATED BY NUMBER IN 0: 1. FURNISH AND INSTALL HEAT SHRINK END CAP. 2. CONTINUATION OF EXISTING #2/0 GROUND BUS CONDUCTOR FROM DCGB -1. I II N i b 11q� X 114111 I ECT. RECT. T - 5p1 B #1 DCGB -1 FGB -1 1E)ATTERY.RACK _ _ _ ._ _ _BATTERY _RACK RECT. 7 . NEW #6 GND. FOR NEW #8 GND. FOR BATTERY 2B DISCONNECT 480V. 1 120PA REFER TO DC DRAWINGS. I I I I I I RECT RECT. _ _ — RECT RECT RECT. _ LA ER E 3 BOX I NEW PANELIBOARD MPDB LI "DP214" I � ❑ PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUNDING -POWER ROOM — - SPDB #1 'ND. FOR Y RACK 1 I F LI I^J PANE. "CRPPAI" T J FUTURE BATTERY 38 DISCONNECT" 480V. DC, 11200A I __ J EXISTI STRIN 1 ROW, EXISTI STRIN 1 ROW #3 2 TIER -24 BATTERY G TERM. PLANT #2 2 TIER -24 BATTERY BATTERY r FUTURE UPS BATTERY 3A CELLS 1 -240 i :L a_-- ---- _____________ — - - - - -- PANEL "CP,PPB1" PANEL , "BPPB2" - - 'I_....___._....._.. _. .1t r 1 INDICATES FUTURE EQUIPMENT L _ i TO BE INSTALLED. ( H- DRAWING SYMBOLS HEAVY LINE INDICATES EQUIPMENTFACE SIDE. 'I'r INDICATES COPPER GROUND BUS. INDICATES HEAT SHRINK END CAP INDICATES H -TAP CONNECTION ELO9 L._ EVIEWED FOR E COMPLIANCE NFPA 70 - NEC FEB 11 2009 Tukwila ILaY DIVISIL RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 II 0 t ots 0 mO M w in I- U' N w II1 ,pwLL is w�O w i 3 Z > ▪ W j so w ,n' ZmN O <12 wz co (0 (I) ( D (i) Lu co Drawn By: IM, PS, ZJ Fac. Code :TYKWWA r1 Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 95% REVIEW 1;00% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 Sheet No. DC PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUNDING - POWER ROOM EXISTING EXTERNAL (+) 48 V. RETURN BUS, 6000A. ---. ------- PDF 165.09-4B • PDF 165.09-3A • ------------- PDF 165.09-2B PDF 165.09-1A --- PDF 144,10-4A PDF 144.10-3A PDF 144.10-2B PDF 144.10-1A EX. (2)-350 MCM'S FROM PDF, TYP, L EX. 750 MOM TO GROUND BAR 000B-1 POSITIVE •8V DISCHARGE BAI''; NEGATIVE 48V DISCHARGE BAR EX. 6 MVO (0) FMK GND. (16)-350 MCM (+) RETURNS FROM PDF 144 AND 165 EXISTING 6-760 EX. SF [)82 4/400A (0 FUSE PANE 1.S) F1,3E 24 400 Aivlp FUSE 23 400 AMP 4BV 48V - 48V --- 48V --- 48V 48V 410V „ 48V 4M/ - 48V 48V .43V 'WV . 48V 'WV 'WV --- 48V 48V -.- -. 48V --- 48V FUSE 1 48V 400 AMP FUSE 22 400 AMP FUSE 21 400 AMP FUSE 20 400 AMP IJSE 19 400 AMP FUSE 18 400 AMP FUSE 17 400 AMP FUSE 16 400 AMP FUSE. 'IS 400 AMP FUSE 14 400 AMP USE 13 400 AMP FUSE 12 400 AMP FUSE 1' 400 AMP FUSE 10 400 AMP FUSE 9 400 AMP FUSE. 8 400 AMP F1JSE 7 400 AMP EU SE 6 400 AMP FUSE 5 400 Amp FUSE_: 4 400 AMP FUSE. 3 400 AMP FUSE 2 400 AIVIP ..401111INEW -- 46V -- 48V I SPARE I SPARE 1 SPARE SPARE SPARE j SPARE i i SPARE I SPARE SPARE J SPARE j SPARE I SPARE 1 SPARE I SPARE I SPARE SPARE SPARE I SPARE SPARE j SPARE SPARE SPARE. SPARE SPARE EX. 6 AVVG (0) FRVVK 0ND. EX'STRK 0-750 ViCIVIrS- G-1 0-4 G-7 G-10 G-2 G-5 D-8 0•3 06 D-9 ...0110010010■111■111111MIMIWIII, EX. SPD 400A (6 FUSE. l'ANELS) FUSE 40 400 AMP FUSE 47 400 AMP FUSE, 40 400 AMP FUSE 45 400 A iV1P FUSE. 44 400 AMP FUSE 43 400 AMP FUSE 42 400 AMP FUSE 41 400 AMP FUSE. 40 400 AMP FUSE :39 400 AMP FUSE 38 400 AMP FUSE 37 .400 Amp POSE 30 400 AIVIP F 35 400 AIVIP FUSE 34 400 AMP FUSE 33 400 AMP FUSE 32 400 AMP FUSE 31 400 AMP FUSE 30 400 AMP FUSE 29 400 AMP FUSE 20 400 AMP F USE. 27 4(11) AIVIP FUSE 26 400 AMP FUSE 25 400 AMP GENERAL NOTES: 1. ALL CABLES #14 AWG AND LARGER TO BE RHW/ HH TYPE, LOW SMOKE (LS)/ NON-HALOGENATED, GRAY COVER D CLASS B OR CLASS I STRANDING. CLASS I (FLEX) CABLE WILI BE USED FOR BATTERY STRING AND RECTIFIER OUTPUT CABLI G. ALL STRANDING IS TO BE TINNED TO HELP REVENT OXIDIATION. ALL CABLE MUST BE "UL LISTED" AND "CT RAT D". BLE PROVIDED FOR POWER IS TO COME EQUIPPED WITH A GRAY OUTER COTTON BRAID COVERING. DLO CABLE IS NOT PERMIUED. 2. ALL WIRE #18 AWG AND SMALLER SHALL E SOL D, TIN PLATED COPPER. MULTI-PAIR CONDUCTORS SHALL HAVE TELECOMMUNICATIONS COLOR CODING vVITH A GRAY JACKET. - 'ISV _-. 48V - 'WV --- 413V - 48V - 48V - 4.8V - 40V 481/ - 'ISV 48V - 'ISV 48V - 40V -- 48V - 48V .-- 48V - 48V 48V - 451/ di8V 48V - 40V -- 48V j SPARE j SPARE SPARE 1 SPARE SP"R" SPARE: j SPARE SPARE SPARE SPARE SPARE 1 SPARE SPARE SPARE SPARE j SPARE SPARE SPARE spARE SPARE SPARE SPARE SPARE E)3 6-750 MCIVI'S- EX. 6 AVVG (0) FRWK GND. I - NO SCALE EX. MPDB 4/400A FUSE (4 PANELS TOTAL) FUSE 64 400 AIVIP FUSE 63 400 AMP FUSE 152 400 AMP FUSE 01 400 AMP FUSE 60 400 AMP FUSE 50 400 AMP FUSE 58 40(1 AMP FUSE 57 400 AMP FUSE 60 400 AMP FUSE 55 400 AMP FUSE 54 400 AMP FUSE 53 400 AMP FUSE 52 100 AMP FUSE 151 400 AMP FUSE ,50 400 AMP FUSE 49 400 AMP CD C) C C) EXISTII` 2-#4/0'S PER RECTIFIER, TYP.- 48'‘i j PDF 144.10-4B -48V. D.C. ONE ---- 4 8V PDF 144.10-3A 4W PDF 144.10-2B 417V j PDF 144.10-1A 3V 1 PDF 165.09-4B ‚I 4 PDF 165.09-3A - 48V PDF 165.09-2B - 48V PDF 165.09-1A - 4V PDF 72-4B, REMOVED 116 PDF 72-3A, REMOVED 'ISV I PDF 72-2B, REMOVED - 48v j PDF 72-1A, REMOVED 4i1V PDF 70-4B, REMOVED 4tIV PDF 70-3A, REMOVED 'ISV PDF 70-2B, REMOVED 48V j PDF 70-1A, REMOVED EX. (2)-350 MCM'S, TYP. C) 0 0 Nial■MILISP (.1-1 G-4 0-7 G-10 0-2 D-5 G-8 0-3 343 G 7 _7 ------------------ EXISTING RECTIFIER OUTPUT CABLES 13- EXISTING - L2 ST1 AC INpuT -- L3 AC EG EX, 13 AWG (0) [ LINE DIAGRAM 1 111. FRWI GN D. EXISTING AC INPUT EX. 6 AWG (0) F RINI( GN D . EXISTING AC INPUT EX. FRWK GNU. 6 MUG (0) _ ' L2 sn L.3 AC ED EX. 0 AWC3 (0)r FRVVIKGND. EXISTING AC INPUT --- ^-•^-•..--,---- .... • • EXISTING - AC IN puT - EX. 6 AWG (0)1 MINK GNU. EXISTING - AC INPUT EX. 6 /MD (0) _ PRWK SING. EXISTING 11± AC INPUT :7 EX. 6 AVVG (0) _ PRINK SING. EXISTING AC IN PUT EX. 6 AWG (0) PRINK ON D. EXI ST1N G - AC INPUT EA. (I AWG (0) PRINK ON D. EXISTING - AC INKrr - ,.-- Ex. 6 A \NG (F4)1 _ F RWK GND. , .1^ • .^ 4., -vs y ^ I.- • y • - '-,•- ^ 4-- -•- -`• 13- EX. -48V L'i 1_3 RECTIFIER 0 -3 L2 U1 400 A AC ED -II t. B+ B- EX. -48V L1 RECTIFIER o -6 L2 131'1 400 A L3 , ACED -1111' B+ EX. -48V B- 1-1 R.ECTIFIER 0 -6 L.2 1ST1 400 A L3 , ACED El- Li" L2 ST1 1_3 ,. ACED B+ TAPS AVAILABLE --f FOR F UT 1.1 RE RECTIFIERS '11-16 .:N.04 .,: ,, , ■ \k(21 M AI V 4 ' A:j.: . ..4'.. ' fu. ,... Exp res 01-05-09 2 01-15-09 3 01-26-09 4 02-02-09 Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: '1 2-12-08 Revision 100% CD ADD. NO. 1 95% REVIEW EX. -48V RECTIFIER G 400 A E)(. -48V RECTIFIER C -2 400 A EX. -48V ECTIFIER G -4 400 A EX. -413V RECTIFIER 0 -7 400 A B- EX. -48V L1 1 SPI REC G -8 L2 400 A La . ACES) B+ E.:X. -48V 8- Li - J ACED RECTIFIER G -9 L2 ST1 400 A L3 - 1 II' B4 - EX. -48V I.1 RECTIFIER C -10 L2 ST1 400A AC PG TAPE, AVAILABLE FOR (4) FUTURE BATTERY SI R I NOS. BATT. 4 BATI 4 BATT. 3 WATT, 3 BAT 2 G. 7 BAIT 2 LL)09%.w 010 ( POSITIVE 48V CHARGE. BAR NEGATNE 48V CHARGE BAR ENCLOSED BUS BARS POSITIVE 48V (..3HARGE NE(ILVI 48'1/ CHARGE BAR REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC 1 IL 1 aid City0fTukwila EXISTING 2-600 IVICM PER P01,..,, RIP( (0) E.X. -48V BATIERY RACK-2 (±) EN E RSY S E GU-45 3990 AFI .1111- EX. -48V BATIE.RY RACK-2 ( Ei\IER,3YS EX I DE GU-45 (-) 3990 AN EX, -48\i -48V BKITERY RACK-2 (f) EN E RS Y EXIDE GU-46 3990 AN E.XISTING AVVG (0) FMK t3 N D. E X IS'f ING 6 AVVG (0) RINK GNI.). EXISTING 6 AVVG (0) F 0ND. RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Sheet No. PERMIT SET M■IM•110.11=11021111111011110011111111111ENIMIr Project No. WTA. 08093 DC-.9 -48 V.D.C. ONE-LINE DIAGRAM IY ! . CELL .� �• —I ( +) CELL 121 JA S 31 -35 ( -) CELL 140 TOP TIER S 26-3) ( +) CELL 101 I-- TOP TIER -- 24 1 ( J ( -) CELL 160 JA S 36-4) ( +) CELL 141 1---- MIDDLE TIER 64 ( +) CELL 161 JA S 41 -45 ( -) CELL 180 1- BOTTOM TIER ( +) CELL 211 MIDDLE TIER o I T IY ! . CELL .� �• 21 ( ) CELL 120 JA S 26-3) ( +) CELL 101 I-- TOP TIER -- 24 1 ( J 62 63 64 - 1 ( +) CELL 81 JARS 21 -2 i ( -) CELL 100 F MIDDLE TIER ( +) CELL 211 MIDDLE TIER - -1 ( -) CELL 80 JARS 16-20 61 ( +) CELL 41 JARS ( +) CELL BOTTOM TIER 0 ( -) CELL 60 BOTTOM TIER IY ! . CELL .� �• 21 +) CELL 1 RS 1 -5 ( -) CELL 201 TOP TIER 24 1 ( J 62 63 64 ( -) CELL 40 J RS 6-1C ( +) CELL 211 MIDDLE TIER I CELLI L. 41 --I ( +) CELL 41 JARS 11 -16 ( -) CELL 60 BOTTOM TIER 57 58 II 60 IY ! . CELL .� �• 21 22 23 24 61 62 63 64 SPARE I CELLI L. 41 I CELL i 80 r r SPARE -I 57 58 II 60 18 19 20 1A 2B 54 3A SPARE SPARE - - 53 55 56 SPARE 1A 13 14 SPARE 15 -- 16 50 rr 3A 51 [52 34 35 SPARE SPARE 30 10 11 12 31 32 SPARE SPARE a 6 26 7 28 8 SPARE 1 SPARE 2 3 4 SPARE IY ! . CELL .� �• L 120 1 •� SPARE -- 61 62 63 64 I CELLI L. 41 I CELL i 80 r r SPARE -I 57 58 59 60 1A 2B 54 3A SPARE 4B - - 53 55 56 SPARE 1A 2B SPARE 4B -- 49 50 rr 3A 51 [52 34 35 36 IY ! . CELL .� �• L 120 1 •� SPARE 45 46 47 48 I CELLI L. 41 I CELL i 80 r r SPARE 41 42 43 44 37 38 39 40 SPARE 33 34 35 36 SPARE 30 29 31 32 SPARE 25 26 27 28 SPARE IY ! . CELL .� �• L 120 1 •� !CELLI 1 ..• �_J I CELLI ---L_r . -J I CELLI L. 41 I CELL i 80 r r dIII TO UPS, DC INPUT N N 2 -350 MCM'S, 1 -3 /0 CND. IN EA. OF (4) 2- 1/2 "C. TO UPS -- 1200A., 480V. DC BATTERY DISCONNECT PROVIDED BY UPS MANUFACTURER 4- 350MCM'S ( +) ON CABLE LADDER ( +) ( -) LINE LINE ( +) LOAD ( -) LINE ( +) ( -) LINE LOAD 4- 350MCM'S ( -) ON CABLE LADDER /4 350MCM'S (+) ON CABLE LADDER NO SCALE #6 TO GROUND BAR 4- 350MCM'S ( -) ON CABLE LADDER #6 TO GROUND BAR #6 TO GROUND BAR #6 TO GROUND BAR - -� 1 () CELL 240 i ( +) CELL 201 ( -) CELL 200 NOTE: ALL POWER CABLES TERMINATED AT BATTERY DISCONNECT JARS 56-6 JARS 51 -55 JARS 46-5) TOP TIER MIDDLE TIER BOTTOM TIER ( +) CELL 221 ( -) CELL 220 ( +) CELL 181 1 SHALL BE TYPE "THWN" OR "THHN ". 3 -TIER RACK NO. 1. 15 UNITS, 60 CELLS. UPS 480V. DC ONE —LINE DIAGRAM (SPLIT STRING) 3 -TIER RACK NO.2. 15 UNITS, 60 CELLS. 3 -TIER RACK NO.3. 15 UNITS, 60 CELLS. 3 -TIER RACK NO. 4. UNITS, 60 CELLS. z R 0 (I) �z w oo r 0 0 O v BRASS OR COPPER NUTS, LOCK WASHERS, FLAT WASHERS AND BOLTS GROUND BAR INSPECTION CUT -OUT PROVIDE CLEAR HEAT - SHRINK OVER ENTIRE BARREL WITH MINIMUM 1 INCH OF CABLE INSULATION COVERED S ANDARD DETAIL 7G102 NO SCALE 1200A. DC BATT. DISCONNECT °° 1111111111lft. SPDB #2 SPDB #1 MPDB UNISTRUT RACK MOUNTED TO FLOOR MPDB AND SPDB ELEVATIONS NO SCALE CLEAN SURFACE WITH CLEANING PAD. APPLY A THIN COAT OF NO -OX -ID AT THE CONNECTING SURFACE. ALL LUGS SHALL HAVE A THIN COAT OF NO -OX -ID APPLIED TO THE STRIPPED CABLE END AND /OR INSIDE OF LUG BARREL BEFORE CABLE IS CRIMPED. TWO HOLE CONCENTRIC COMPRESSION TYPE COPPER, LONG BARREL LUG (BURNDY"YA" SERIES OR EQUAL BY "T & B ") WITH COPPER OR BRASS BOLTS AND LOCKWASHERS. PROVIDE 2 "x3" PHENOLIC I.D. TAG FOR EACH CONDUCTOR. CRIMP TOOL SHALL BE HYDRAULIC TYPE, WITH FULL CIRCUMFERENCE DIE CRIMPING TOOL, LUGS SHALL HAVE THE NUMBER OF CRIMPS INSTALLED PER MANUFACTURER'S RECOMMENDATION. GROUNDING CONDUCTOR TERMINATION DETAIL N- 8.56 " - SCALE: 3/8 " =1' -0" NEW 1-6L CABLE LADDER r rd ANC dobb.iimil k 34" TYP. II 7' -0" I_ II II II I AA BATTERY RACK SINGLE ROW 3 -TIER (TWO PER STRING) SPILL CONTAINMENT WITH ACID ABSORBING PILLOWS 60 BATTERY UNITS TOTAL, 4 -CELL EACH NOMINAL 480V. DC. (C &D 240XT4LC -15) ---- 0 0 CABLE RACK +4-1" A.F.F. $ TOP OF %1 LIGHT Air i ; re rat s COMMUNICANTION CABLE LADDER ROOF VARIES +9 A.F.F. NEW WOOD BATTEN r uT �ItE LCUli ME.r11 f O uM WALL MOUNTING HOLES BATTERY RACK ELEVATION C & D 9DB 0902 (18) 4' PVC SLEEVES NEW SECURED WALL— I - WATERFALL OFF CABLE LADDER 3' -0" EL09 0i0( —EXISTING FUSE POSITION PREVIOUSLY SERVING PDF 42 TO SERVE LOAD PANELS ON NEW PDF 144.10 EXISTING FUSE POSITION PREVIOUSLY SERVING PDF 68 TO SERVE LOAD PANELS ON NEW PDF 165.09 —EXISTING FUSE POSITION SERVED LOAD PANELS ON PDF 70 HAVE BEEN REMOVED. EXISTING FUSE POSITION SERVED LOAD PANELS ON PDF 72 HAVE BEEN REMOVED. SECTION SCALE: 1/4"=1'-0" -- 20.81" - 07E P2-f) REFER TO ARCHITECTURAL DRAWINGS FOR NEW SECURED WALL ATTACHMENT. REFER TO ARCHITECTURAL DRAWINGS FOR PENETRATION OF AUXILIARY FRAMING THRU NEW SECURED WALL. CABLE TRAY pai +18' -7' A.F.F. AUXILIARY FRAMING POWER CABLE Da +17-1" A.F.F. LADDER COMMUNICANTION +1d -7" A.F.F. CABLE LADDER Ili CONC RAISED FLOOR +7 - 3" A,F.F. RETE FLOOR — 4"" E.... CEWED FOR A 70- r FEB 1 1 Mg BALDING pM NEW 1-6 CABLE LADDER CELL I nn BATTERY RACK SINGLE ROW 3 -TIER SECURE ON EACH RACK OWED CONCRETE FLOG I U�D 5/8" ANCHOR BOL S AS r il1KWILA RECOMMENDED BY A� 0 5 , MANUFACTURER PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS S Ci MA WA S • ti; C >. c` -vf r R • y-W Expires 1 01 -05 -09 2 01 -15-09 3 01 -26 -09 4 02 -02 -09 Fac. Code :TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, 2J Proj. Mgr.: KCM Date: 12 -12 -08 Revision Project No. WTA. 08093 Sheet No. 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET DC -10 UPS 480 V. DC ONE LINE DIAGRAM AND BATTERY RACK DETAILS