HomeMy WebLinkAboutPermit EL09-0342 - LIFEWAY CHRISTIAN STOREUFEWAY CHRISTIAN STORES 17326 SOUTHCENTER PY ELO9-0342 Parcel No.: Address: Suite No: CitjaNf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: htt.• / /www:ci.tukwila.wa.us 17326 SOUTHCENTER PY TUKW ELECTRICAL PERMIT Permit Number: EL09 -0342 Issue Date: 07/16/2009 Permit Expires On: 01/18/2010 Tenant: Name: LIFEWAY CHRISTIAN STORES Address: 17326 SOUTHCENTER PY , TUKWILA WA Owner: Name: Phone: Address: Contact Person: Name: KEVIN WEARE Phone: 206 - 795 -2629 Address: 4000 DELRIDGE WAY SW , SEATTLE WA Contractor: Name: ABACUS ELECTRIC CO Phone: 253 984 -1611 Address: 9804 SALES RD S STE A -1 , LAKEWOOD WA Contractor License No: ABACUEC928LT Expiration Date: 06/30/2010 DESCRIPTION OF WORK: ELECTRICAL FOR TI REVISION #1: LOW VOLTAGE WORK ADDED TO SCOPE Value of Electrical: NRES: $20,750.00 Fees Collected: $540.50 RES: $0.00 Type of Fire Protection: UNKNOWN National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and eta Date: otio -L 7 ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t ormance of . am au rized to sign and obtain this electrical permit. p _77_ 61/�,/ Signature: /`fry Date: Print Name: �i r�✓� Z------774 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0342 Printed: 08 -07 -2009 Parcel No.: Address: Suite No: Citydlif Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: htlp: / /www.ci.iukwila.wa.us 17326 SOUTHCENTER PY TUKW ELECTRICAL PERMIT Permit Number: EL09 -0342 Issue Date: 07/16/2009 Permit Expires On: 01/12/2010 Tenant: Name: LIFEWAY CHRISTIAN STORES Address: 17326 SOUTHCENTER PY , TUKWILA WA Owner: Name: Phone: Address: Contact Person: Name: KEVIN WEARS Phone: 206 - 795 -2629 Address: 4000 DELRIDGE WAY SW , SEATTLE WA Contractor: Name: ABACUS ELECTRIC CO Phone: 253 984 -1611 Address: 9804 SALES RD S STE A -1 , LAKEWOOD WA Contractor License No: ABACUEC928LT Expiration Date: 06/30/2010 DESCRIPTION OF WORK: Value of Electrical: NRES: $20,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $520.00 National Electrical Code Edition: 2005 Date: 01" I I hereby certify that I have read and xar ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie vent whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signatur Print Name This pe or aban / y/�c�3S Date: V— /C ' Og all become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended ned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0342 Printed: 07 -16 -2009 Parcel No.: Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17326 SOUTHCENTER PY TUKW LIFEWAY CHRISTIAN STORES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL09 -0342 ISSUED 06/01/2009 07/16/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signatur Print Nam Date: .7-/6 ^ 0(1' doc: Cond -Elec EL09 -0342 Printed: 07 -16 -2009 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us 0 • Electrical Permit -No.^� .. t Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION r King Co Assessor's Tax No.: .V6, Z 3Z-9 1-f 9/ /Q ' Site Address: / 7 2- ‘,, SaUv�2,�e Par-44A/ / / Suite Number: Floor: Tenant Name: G /jam° �✓2 C� 0-Air/f7 //0/11 New Tenant: g, Yes ❑ ..No Property Owners Name: f' 1/2 71l,(), Lt-C- ./44C-t0 Mailing Address: '.? 3 27 AiYAAJ 9? Pie ,PA,OA, /oO Area✓ /J'1 i e dok , ✓ 2_— / City ./ State Zip CONTACT PERSON - Who do we contact when your perinit,is'r'eady to,be issued ' Name: Mailing Address: Yv1g° , //'/D C>° e ch.) / S E -Mail Address: /&I//A/CL, 0 e" -oL 'i 3 /,q S env( /rtlP %,Gd yYj • Day Telephone: 20 6 1675 9 City State Zip Fax Number: ' 6 'l}3 /37 9 , r ELECTRICAL CONTRACTOR INFORMATION Company Name: ti A/KRJtxAt) - Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Project (contractor's bid price): $ .2C7, &g--p Scope of Work (please provide detailed information): Will service be altered? ❑ Yes Er No Type of Use: %,(Q /(✓ S�k� Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light Adding more than 50 amps? ❑ Yes ❑ No ❑ Service Change ❑ Fire Alarm HAApplications \Forms - Applications On tine \I -2009 - Electrical Permit Application.doc bh ❑ Remodel Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ..$145.60 (including an attached garage) ❑ Garages, pools, spas and outbuildings $78.00 ea ❑ Low voltage systems (alarm, furnace thermostat) . .. $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $57.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Mailing Address: y0:900n /.,D- Alt Ski IDate Application Accepted: ` „ 1_ 0,1 Day Telephone: L City Date: Azt° ?CtrJ J Kffi State tip Date Application Expires: () _ Staff Initials: H: ''Applications\Forms- Apphcanons On Line\ 1.7009- Electncal Permit Apphcatton.doc bh Page 2 of 2 Parcel No.: Address: Suite No: Applicant: LIFEWAY CHRISTIAN STORES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17326 SOUTHCENTER PY TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: EL09 -0342 ISSUED 06/01/2009 07/16/2009 Receipt No.: R09 -01240 Initials: User ID: JEM 1165 Payment Amount: $20.50 Payment Date: 08/07/2009 10:31 AM Balance: $0.00 Payee: ABACUS ELECTRIC COMPANY TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. 5850 20.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 16.40 4.10 Total: $20.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -07 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: EL09 -0342 Address: 17326 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 06/01/2009 Applicant: LIFEWAY CHRISTIAN STORES Issue Date: Receipt No.: R09 -01067 Initials: WER User ID: 1655 Payment Amount: $104.00 Payment Date: 07/09/2009 02:31 PM Balance: $0.00 Payee: RRMM ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10773 104.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 104.00 Total: $104.00 AYMENT RECEIVE doc: Receiot -06 Printed: 07 -09 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.ttikwila.wa.us RECEIPT Parcel No.: Permit Number: EL09 -0342 Address: 17326 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 06/01/2009 Applicant: LIFEWAY CHRISTIAN STORES Issue Date: Receipt No.: R09 -00815 Initials: WER User ID: 1655 Payment Amount: $312.00 Payment Date: 06/01/2009 02:38 PM Balance: $104.00 Payee: RRMM ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16749 312.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 312.00 Total: $312.00 E ECEVED doc: Receiot -06 Printed: 06 -01 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: EL09 -0342 Address: 17326 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 06/01/2009 Applicant: LIFEWAY CHRISTIAN STORES Issue Date: Receipt No.: R09 -00814 Initials: WER User ID: 1655 Payment Amount: $104.00 Payment Date: 06/01/2009 02:37 PM Balance: $416.00 Payee: RRMM ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16749 104.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 104.00 Total: $104.00 CEVE() doc: Receiot -06 Printed: 06 -01 -2009 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 D312 PEI MIT N0. 1 (206)431 -360 Prott:� ` CICT1411 Type of Inspection: �t�1' Address: 1 %11] 5 •c. py. Date Called: Special Instruction Date Wanted: t 31 p.m. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: k KAI Date: OW? icy7 n $60.00 REINS ECTION FEE R UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISI ON 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit -O311 PERMIT NO. R (206)431-367 Project 11ot11i� t T ( Type of Inspection: 7 r /e/�✓� Address: j732 `� , B Q� • Date Called: Special Special Inst ctions: Date Wanted: Od qr,„.. Requester: Phone No: IX I Approved per applicable codes. El Corrections required prior to approval. COMMENTS: � - z LC��+�Jc, covN(, 441.1- (A) Inspector: 131t4PiCt Date:O m I ri $60.00 REINSP CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD 1,1)t J p3�� Retain a copy with permit 1 P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ` (206)431 -367 Project: Ll� r, 6 a5 - f`^/'f�� Type of Inspection/ ?00 Address: Date Called: Specidl9nstructions: Date Wanted: � V 4.w... m• Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: PK - ufbeist.A5 7oo,3 rA- LAJA1V Inspector: Date:o7 7, -74 v El $60.00 REINSPECTION FEE lelfA UIRED. Prior to inspec ion, fee mu t be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Interior Lighting 2006 Washin•ton State Nonresidential Energy Code Compliance Form Summary • 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Revised Julv 2007 Project Info Project Address Lifeway Christian Store Date 4/30/2009 Parkway Supercenter For Building Department Use ''''.114017tetc- *I Tukwila, WA Applicant Name: Anthony D. Gipson Applicant Address: 301 Industrial Boulevard, Tullahoma, TN 37388 Applicant Phone: 931- 454 -9940 ^7^ Project Description Sales ❑ Plans Included requirements. ❑ New Building ❑ Addition -I Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option . 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2'• Area in ft2 Allowed x Area Sales Retail Space 1.50 6764.0 10146.0 Sales Recessed fixtures at Displays (J), 1 -50W Incandescent 10 50.0 500.0 Processing 4' Wraparound fluorescents (M /N), 2 -32W T8, Elect. Hal 12 62.0 744.0 rom Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 10146.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales 2' x 4' Lay -In Fixtures (A & B), 3 -32W T8, Electronic 68 95.0 6460.0 Sales Recessed fixtures at Displays (J), 1 -50W Incandescent 10 50.0 500.0 Processing 4' Wraparound fluorescents (M /N), 2 -32W T8, Elect. Hal 12 62.0 744.0 Sales Track at Point of Sale (D), 1 -60W Incandescent (Ft. of 12 50.0 600.0 Sales Cornice Lighting (F), 1 -32W T8, Elect. Ballast 31 35.0 1085.0 Sales Display Track Ltg (Halogen and Metal Halide) (Ft of� F Exception taken for track per Table 15 -1 Footnot 47:0!!!jotti •\ CE A 70 NEC 0 4 4%- -+ ift4 otal Proposed Watts may not exceed Total Allowed Wa Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp ty included). For track lighting, list the length of the track (in feet) in 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the Ixture n� •i• he lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. s for Interior Total Propose Watts 9389.0 , and ballast type (if ormation. ELO° 03L12. RECEIVED JUN 01 2009 PEHMIT CENTER 2006 Washington State Nonresidential Energy Code Com•liance Form Interior Lighting'; Sumrnary (back LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: ° Warehouses, storage areas or aircraft storage hangers °Other Qualification Checklist Note: If occupancy type is 'Other" and fixture answer is checked. the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. It not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Liahtina Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /bars 1.3 Post office 1.1 Dormitory 1.0 Retail'", retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hall'•' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ftZ may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Enerav Code Compliance Form ■ Lighting,. Motor; 2006 Washington State Nonresidential and Transformer H er n1 it Plans .Checklist LTG -CHK Energy Code Compliance Forms Revised July 2007 Project Address Lifeway Christian Store 'Date 4/30/2009 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yea 1513.1 Local controVaccess Schedule with type, indicate locations s -2 yee 1513.2 Area controls Maximum limit per switch E -2 yes 1513.3 Daylight zone control Schedule with type and features, indicate locations 5 -2 yes vertical glazing Indicate vertical glazing on plans 5 -2 n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E -2 yee 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability). Indicate size of zone on plans s -2, 3 yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning E -2 EXIT SIGNS (Section 1514) yen 1514 Max. watts Indicate watts for each exit sign E -2 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yee 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. 1511 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) a. a. I 1540 (Transformers 'Indicate size and efficiency IE -3 I If "no" is circled for any question, provide explanation: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1/ Plan Check/Permit Number: 2-79 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Or Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: 77 Contact Person: Phone Number: %'6 --7/ 3/°i� Summary of Revision: CITY Tr�NKKwI A AUG 0 7 2009 PERMIT CENTEF, Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: / Entered in Permits Plus on VII 01", oil \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Reviced• *PERMIT fu ;r •: i COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL09 -0342 DATE: 06 -01 -09 PROJECT NAME: LIFEWAY CHRISTIAN STORES SITE ADDRESS: 17326 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 12ngi ofn Public Works n 1AL1 Fire Prevention Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-02 -09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route 54 Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved qj Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06-30-09 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/roubng slip.doc 2-28-02 Untitled Page • 0 Page 1 of 1 Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type ABACUS ELECTRIC CO 2539841611 9804 SALES RD S SUITE A -1 LAKEWOOD WA 98499 PIERCE Limited Liability Company Parent Company ABACO CONTRACTORS LLC UBI No. Status License No. 602838703 ACTIVE ABACUEC928LT License Type ELECTRICAL CONTRACTOR Effective Date 6/30/2008 Expiration Date 6/30/2010 Suspend Date Specialty 1 GENERAL Specialty 2 UNUSED ADMINISTRATOR INFORMATION License MOSS *HT928Q4 Name Moss, H TROY JR Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MOSS, HAYWOOD TROY PARTNER /MEMBER 06/30/2008 Bond Amount SMITH, SHANE PARTNER /MEMBER 06/30/2008 LPM4076005 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 COLONIAL AM CAS E SURETY OF MARYLAND LPM4076005 06/27/2008 Until Cancelled $4,000.00 06/30/2008 https://fortress.wa.gov/lni/bbip/Detail.aspx 07/16/2009 TRANSFORMER FOR DOORBELL BUZZER (VIA LCP -13) (VIA LCP-14) EDIN- cal 11 15" 111 ■ CHURCH RESOURCES 104 RTU\\ 4 RP -11 REFERENCE 105 IRTU 3 OP- L __ BIBLES 106 RP -27 1 I j 111 IS' i 1 HALLWAY 2 111 DOORBELL PUSHBUTTON • COORDINATE LOCATION OF DOORBELL BUZZER a- #17 Po- #15,#1S, 26 RP -25 #16 ■r 1 In/ May X11 1'H(_:)\ll:-. L30A1--1> AEL)VE RP RP -34 PROLE SING ROOM 10s 1 /2 "C, (2)#10 4 n 54" 54" CHILDREN'S 114J BOOKS IOGt RP -IS 4' -6" 1 10 A_ l!JI'!' #se�o`� #13 PPP- 4' RP -28 (TIE) P POVER LA"i SCALE: I/4 " =1' -0" NORTH 111 RP -17 (11E) #10 IL (I) #10G LP LCP RP -4O RP -4 RP -2 RP -6 BREA 60” A.F.F. i I I l L RP -23 ANL RP -12 RP -38 111 MANAGER OFFICE 12 #1 #2, #3 1 111 111 -22 GENERAL OFFICE 110 #5, #7 /1► RP -9 HALLWAY 103 RP -13 Ow- 16 (RTU 2 RP- 2 48" MEN'S TOILET RP -20 J PJ 101 WOMEN'S TOILET 102 t 11' -6" R7 FLA MUSIC 113 REVISION S No changes shat be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions wil requiro a new plan submittal and may include s.ddition al plan review fees. SEPARATE PERNIIIr REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION RP -26 RP -7 (VIA LCP- 15) �'�f RP -5 (VIA LCP -16) ENTRY 116 I6 L goo- 111 GIFTS 115 RP -28\ 16 16 RP -24 RP -8 86" A.F.F. / / Eco- rdihn `!J S I -O" 18" -u r PROJECT SPECIFIC NOTES: RP -1O CONTROL PANEL AND DEDICATED CIRCUIT FOR EAS. COORDINATE LOCATION FOR EAS CONTROL PANEL BEFORE INSTALLATION, SEE EAS INSTALLATION DETAIL ON THIS SHEET, RECEPTACLE SHALL 13E CENTERED ABOVE DOORS AND SWITCHED FROM P.O,S, AREA FOR OWNER "OPEN" SIGN. INSTALL SERVICE RECEPTACLE (WP /GFC I) AT EACH RTU, CONNECT TO RP -36, I -1 /4 "C RUN iN FLOOR FOR STAR MUSIC SYSTEM CABLE, PROVIDE I -I/4 "C STUB -UP ABOVE CEILING FOR STAR MUSIC SYSTEM. ELECTRICIAN RESPONSIBLE FOR ALL EXTERIOR SIGN FINAL CONNECTIONS (2 SIGNS, 4 CIRCUITS), COMPUTER BOARD LOCATION FOR COMPUTER SYSTEM - PROVIDE 2" CONDUIT AND ROUTE DOWN WALL. COORDINATE EXACT LOCATIONS OF OUTLETS WITH OWNER AND WITH DETAILS /ELEVATIONS ON SHEET E -3, PLACEMENT OP OUTLETS AS 15 RELATES TO THE SCOPE OF T1-115 PROJECT 15 CRITICAL, VERIFY ALL NECESSARY CONDITIONS BEFORE INSTALLING TO ENSURE LOCATIONS ARE CORRECT, COORDINATE ALL RECEPTACLE, JUNCTION BOX, AND DATA OUTLET LOCATIONS, AS WELL AS THE REQUIRED SAWCUTT ING OF SLAB, WITH THE TENANT, COORDINATE EXACT DEVICE LOCATIONS WITH OWNER AND ARCHITECTURAL DETAILS PRIOR TO ROUGH -IN, P,O,S. CABINET POWER, EACH CABINET TO 13E PROVIDED WITH SURFACE MOUNTED DUPLEX BOXES, DRILL ACCESS HOLES IN SIDES OF CABINETS AS NECESSARY, CONTRACTOR AND ELECTRICIAN SHALL COORDINATE THIS WORK AFTER THE CABINETS ARE INSTALLED AND BEFORE OWNER INSTALLS COMPUTER, SEE ARCHITECTURAL DEAT ILS, STAR MUSIC SYSTEM SERVER LOCATION, PROVIDE 6 "x6" J -I=3OX MOUNTED l8" AFF. ROUTE 1 -1 /4 "C TO ALL MUSIC SYSTEM FLOOR BOXES, PAGING SYSTEM= DIRECT CAT 3 LiNE FROM PHONE BOARD TO AUDIO /VIDEO CABINET. INTERFACE WITH IN -STORE MUSIC SYSTEM, BY OWNER, INSTALL ON -HOLD MARKETING MODEM ON TELEPHONE BOARD, CONNECT TO LAST ROLL OVER TELEPHONE NUMBER, BY OWNER, COPIER CIRCUIT TO HAVE ISOLATED, DEDICATED GROUND, COORDINATE HEIGHT /LOCATION OF OUTLETS WITH ARCHITECTURAL DRAWINGS, CONDUIT AND CIRCUITS SHALL BE ROUTED THROUGH SLAB, MINIMIZE SAWCUTTING OF SLAB AS MUCH AS POSSIBLE. COORDINATE OUTLET LOCATIONS AT SHIPPING COUNTER WITH ARCHITECTURAL DETAILS, JUNCTION BOX FOR CHECKPOINT SECURITY KEYPAD MOUNTED NEXT TO "OPEN" SIGN LIGHT SWITCH. INSTALL NEW LIGHTING CONTROL PANEL AS DESCRIBED ON E -2 AND E -3, PUSH BUTTON AT REAR DOOR TRANSFORMER BELL (COORDINATE LOCATION WITH OWNER) DOOR CHIME SYSTEM: EDWARDS MFG, OR EQUAL PUSH BUTTON: EDWARDS WO BUZZER EDWARDS 34OA -65 MOUNTED PER L IFEWAY INSTRUCT IONS TRANSFORMER= EDWARDS 592 DOO1R C1-41INIE SCHEMATIC DIAGRAM NOT TO SCALE LEECIE:NID: IN PHONE /DATA (DEDICATED 3/4" CONDUIT STUBBED ABOVE CEILING FOR EACH OUTLET) DUPLEX RECEPTACLE, 120V, 20A SWITCH, 120V, 20A FLOOR BOX FOR MUSIC SYSTEM CABLING FLOOR RECEPTACLE, 120V, 20.4 0 CEILING RECEPTACLE, 120V, 20A i-r QUADRUPLEX RECEPTACLE, 120V, 20,6, CLOCK HANGER 'RECESSED WALLPLATE 'a FEATURE WALLS k SLATWALL DUPLEX RECEPTACLE, 120V, 20A, SEE MOUNTING DETAIL, THIS SHEET, FOR REQUIREMENTS a GFC I DUPLEX RECEPTACLE, 120V, 204,, MOUNTED S" ABOVE COUNTERTOP CEILING MOUNTED SPEAKER FILE COPY Permit No. �. 1 Plan review approval is subject to errors and omissions.. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Date. City Of "Tukwila BUILDING DIVISION FOR RECEPTACLES MOUNTED ` '-O" AFF FOR FEATURE WALL SIGNS (CENTERED N WALL), INSTALL RECESSED DISPLAY RECEPTACLE IN THE WALL TO ALLOW SIGN TO BE PLUGGED IN FLUSH WITH WALL. USE PASS 4 SEYMOUR 53713 RECESSED RECEPTACLE OR EQUIVALENT, REFER TO ARCHITECTURAL DRAWINGS, CEILING MOUNTED STOREFRONT RECEPTACLES ON CIRCUIT RP -14. WIRING NOT SHOWN FOR DRAWING CLARITY, ELECTRICIAN TO PROVIDE BUS BAR AT PHONE BOARD, COORDINATE WITH L IFEWAY TELEPHONE EQUIPMENT INSTALLER ON -SITE, ELECTRICIAN 15 RESPONSIBLE FOR OBTAINING A LOW - VOLTAGE WIRING PERMIT IF REQUIRED, ALL FLOOR CUTS AND TRENCHING FOR UNDERGROUND ELECTRICAL AND LOW - VOLTAGE CABLING TO BE WET SAW -CUT ONLY AND MANUALLY REMOVED, NO JACKHAMMERINCx ALLOWED, ELECTRICIAN TO INSTALL. AND ROUTE ALL CONDUIT IN OFFICES UNDER THE STORAGE PLATFORM TO ENSURE THAT ALL LOW - VOLTAGE CABLING CAN BE RUN DIRECTLY FROM EACH OUTLET IN THE PLAN BACK TO THE COMPUTER CABINET. COORDINATE THIS WORK ON -SITE AS NEEDED DURING FRAMING CONSTRUCTION OF THE STORAGE PLATFORM, CONTRACTOR TO PROVIDE AND INSTALL 4' x 8' TELEPHONE BACKBOARD AND 3' x 3' EQUIPMENT 4 COMPUTER BOARD, PAINTED BLACK, SEE DETAIL ON SHEET E -3 FOR MOUNTING REQUIREMENTS, P,as, FLOOR CUT REQUIREMENTS= 3/4 "C STUB -UP FOR P,O.S, HUB 4 3/4 "C TO FLOOR MOUNTED JUNCTION BOX FOR POWER TO P.O.S. EQUIPMENT, NOT USED JUNCTION 150X WITH 1 -1/4" MINIMUM CONDUIT DOWN WALL, STANDARD OUTLET, STANDARD DATA PORT WITH 3/4" CONDUIT, OUTLETS AND JUNCTION BOXES TO BE MOUNTED 'a 18" A.F.F. SWITCH FOR "OPEN SIGN" MUST OPERATE "OPEN SIGN" ONLY AND CANNOT ISE TIED INTO REAR P,O,S, OUTLETS, SWITCH MOUNTED 42" A.F.F.. WALL - MOUNTED FLAT PANEL TV BY OWNER, BRACE WALL AS REQUIRED, OUTLET DEVICES AT 54" AFF, JUNCTION BOX FOR AUDIO /VIDEO CABLING, BOX SHALL BE MOUNTED IS" A,F.t=, AND SHALL INCLUDE 1 -1/2" CONDUIT TO AREA ABOVE CEILING. EXTEND EXISTING FEED FROM 2004 SERVICE DISCONNECT TO PANEL 'LP'. ENSURE CIRCUIT 15 2 "C, (4) #3/0 4 (1) #6G. SUSPEND FLAT PANEL TV ACCESSORIES: THE TELESCOPIC SUSPENDED TV MOUNTING SUPPORT PiPE (FEMALE) SHALL BE INSTALLED 5O THAT THE BOTTOM OF THE PIPE (THREADED END) 15 10' -0" AFF, THE EXTENSION PIECE OF THE SUPPORT ASSEMBLY (MALE) AND TV SUPPORT BRACKET SHALL SE PROVIDED TO THE OWNER AT TURNOVER THE TELESCOPIC MOUNTING ASSEMBLY i5 PROVIDED BY OWNER TO THE LANDLORD CONTRACTOR FOR INSTALLATION PRIOR TO CEILING GRID INSTALLATION, PROVIDE A CEILING MOUNTED OUTLET NEAR PIPE ASSEMBLY FOR POWER TO THE TV, Conduit should be 66" on center and centered on opening. 21 4" EAS Pedestal by Owner 3/4" Conduit -- Stubbed up at each EAS Pedestal locations and above ceiling. MUST BE EXACT FOR OWNER PROVIDED SECURITY EQUIPMENT. The stub up above the ceiling can be placed anywhere at storefront as Ions as the it is no closer than 5'0" from pedestal locations. Outlet should be located next to stub up, Use only "swept" Angles and provide Pull - Strings. 0 0 v� v v 0 0 0 cn 0 .5 v 0 I- 0 r 0 v 0 - 0 0 0 a) v 0 0 0 v v 0 — MEWED FOR_`. COMPLIANCE NFPA 70 - NEC JUN 0 4 2UiJ i hwila .J3LIILDING I !VISION EAS Control Panel should be a minimum of 510" from the nearest EAS pedestal. By Owner. Outlet to be on dedicated circuit, Locate ae shown on Power Plan, E -I, By General Contractor. Mark circuit EAS Loss Prevention Ec u iprnent Power aro Conduit Recuirernents Scale: NONE FOWE /W i ING INFOIRMATION FOR I--IVA C EQUFMENT Notes met, r� , Cable Type: HVAC# DISCONNECT SIZE CONDUIT /WIRE SiZE PSEDER PANEL FEEDER BREAKER(S) RTU -1 EXISTING TO REMAIN EX EXISTING LP 2,4,6 RTU-2 EXISTING TO REMAIN EX EXISTING LP 8,10,12 RTU -3 EXISTING TO REMAIN 1/2" (3) #12 4 (1) 4:012 GND. LP 1,3,5 RTU -4 EXISTING TO REMAIN 3/4" (3) #8 4 (1010 GND. LP 14,16,18 Phone and Communication Cabling and Equipment Schedule Project: Tukwila, WA .'-"Nt . Notes met, r� , Cable Type: CAT 5E CAT 5E # Location Voice Data By owner � Pull all cables from location on drawing to: 4x8 Phone Board 3x3 Computer Board 1 Manager's Office x x NEC 16 Button LCD Speakerphone 2 Manager's Office x x PC 3 Manager's Office x x Printer 4 General Office x x Spare Data 5 General Office x x NEC 16 Button Display Speakerphone / WAN PC 6 Stockroom x x Copier 7 General Office x x — Server 8 General Office x x Spare 9 Church Resources Work Station Not Used 10 Books Work Station x x NEC 16 Button Non - Display Speakerphone / PC 11 POS Cabinet x for Hub installation (by others) 12 POS Cabinet x Spare 13 POS Counter x x Cordless Phone / Spare Data 14 Not Used 15 POS Counter x x NEC 16 Button LCD Speakerphone / Printer 16 Receiving Counter x x NEC 16 Button Non-Display Speakerphone / PC 17 Telephone Board Work x hstall On Hold Marketing Modem 18 ISD Support Line @ Equipment Board x Support modem direct connection to dedicated phone line Block on phone board. 19 Credit Card Line @ Equipment Board x Support modem direct connection to dedicated phone line @ Block on phone board. 20 VPN Line at Server Cabinet x Direct connection to dedicated phone Tine @ Block on phone board. 21 Overhead Paging Speakers Connection @ P.O S. Counter x Connect NEC Equipment for overhead speaker paging interface. 22 Not Used 23 Not Used 24 Not Used 25 Ti Wide Area Network (WAN) Circuit x from Telephone Board to Port #24 on Patch Panel Patch Panel Cords x * *Refer to Section 16741 in Project Manual for detailed scope of work, specifications, and cabling requirements and responsibilities Cabling material and installation provided by Contractor. All cables should be continuity tested by Contractor before Owner work is performed. Final termination and punch down requirements by Owner. Equipment Technician, Larry Sloan cc 205 -527 -6352. EL0' RECEIVED JUN 01 2009 PERMIT CENTEF O312 -0 0 00 1!>: 622-6883 rn r g 1-- V! z resell W3 mlitem) X v 41 v 0 cL 1- 0 CA 1- z z Biblical Solutions for LLJ {— LLJ (f) i_ z a CD 4 c 0 s_ POHER PLAN TYPICAL NOTE: EACH "J" TYPE FIXTURE IS 6" FROM WALL AND CENTERED ABOVE THE 4' SECTION BELOW 1'�IU�IE [3 (:)AH.1> ADC )VF _ HALLWAY 2 INPUT TO LCP, SEE MANAGER'S OFFICE 112 CIRCUIT CONT INUED BELOW GENERAL_ OFFICE PROCESSING R OM ME TOI ET S CHURCH RES.URGE 104 TOILET -o F HILOREN'S F4 • • • 0 11i C7 LIJ K vI FIX-RARE M ULE TYPE MANUFACTURER CATALOG # LAMPS VOLTAGE MOUNTING TYPE/REMARKS A LIGHTOLIER SPS2GFSVA332- UNY -03 (3) 32 WATT FLUOR, T8 277 LAY -IN 2'x4' ACRYLIC LAY -IN FOR OFFICES, PROCESSING ROOM, 4 NON - SALES -AREA B LIGHTOLIER SPS2GFSVA332- UNV -O3-0 (3) 32 WATT FLUOR, TS 277 L,4Y -IN * *SAME AS "AA" WITH EMERGENCY BATTERY BACKUP EXIT LIGHTOLIER TX1RCWN LED (3,2W TOTAL) 277 CEILING /WALL EXIT SIGN WITH EMERGENCY BATTERY PACK J LIGHTOLIER I027WIN /1002P1 (I) 50 WATT P,4R20 120 RECESSED CENTERED ON 4FT SECTIONS, SEE FIXTURE PLAN, BIBLE AREA ELEVATION, M LIGHTOLIER SW4S2321- 1PFUNVHI (2) 32 WATT FLUOR. TS 277 PENDANT FOR USE IN THE RECEIVING ROOM AREA SUSPEND 121-0" A.P.F. N LIGHTOLIER SW4S2321- IPFUNVI -11 (2) 32 WATT FLUOR. TO 277 PENDANT SAME AS "M" WITH EMERGENCY BATTERY PACK Y LICxHTOLIER LVL -B-WL (2) 5,5 WATT MR -16 HALOGEN 277 SURFACE ABOVE DOOR EMERGENCY EGRESS FIXTURE D LIGHTOLIER I- 7599W1 -1, 1- 5100 -81NV, I- F5I76NV 60 WATT INCAND, 120 TRACK HANGING SHADE, CUT CORD SO THAT BOTTOM OF SHADE f5 38" ABV COUNTER F(1) LIGHTOLIER SNI4ORSHPF- 12O -SO (1) GF32TS /6f 35 /RS 120 SURF, CORNICE F= 4 FT, /F1 .1 3FT, SEE ARCI- IITECTURAL DETAIL, INSTALL REFLECTORS K LIGHTOLIER S201WI -I / 8239W1-1 (1) G5OPAR30 / HIR / FL (HALOGEN) 120 TRACK 50W FLOOD, QUANT IY AS SHOWN ON DRAWINGS WITH TRACK, W LIGHTOLIER 8292WEW1 -I (1) GE #56945 120 TRACK METAL HALIDE LAMP FIXTURE, CONTACT LIFEWAY LIGHTING SUPPLIER FOR PRICING AND MATERIAL LOGISTICS COORDINATION, JAMES TURNER, GRAYBAR ELECTRIC, 615- 394 -4352 ALL TYPE 'F' 4 'FI' FIXTURES ARE TO BE WIRED TOGETHER ON ONE CIRCUIT (RP -16, VIA LCP -10). �— WIRING NOT SHOWN FOR DRAWING CLARITY. 611 SEE DETAIL 1, SWEET A-6 4 TYPICAL INSTALLATION DETAIL, THIS SHEET DETAIL - TYPE 'J' FIXTU F SCALE- NONE • RP -37 (XIA LC -7) RP 3 (VIA CP -S) BOOKS LP- (VIA LCP -2) , F 1 err 1 111/ liiirMaiiii SCALE: I/4 "= I' -O" PLA NORTH 0 3d JUNCTION BOX SHOULD NOT BE INSTALLED IN THE MIDDLE OF A CORNICE SECTION RUN \CMMS CORNICE LIGHTING WIRING JUNCTION BOX HEIGHT TO FEED POWER TO LIGHTS IS 7'-&" AFF, IF NO JUNCTION BOX IS USED, PULL WHIP DIRECTLY THROUGH WALL AT THIS HEIGHT, COORDINATE WITH CORNICE LIGHTING DETAILS - THIS SHEET, INSTALL SWITCHES TO CONTROL TI-IE LIGHTING IN THE INDICATED ROOMS SEPARATELY, SWITCHES TO BE MOTION SENSOR TYPE IN ALL ROOMS, FOR TOILETS, BREAKROOM, AND OFFICES, USE WATTSTOPPER MODEL #WA -2O0, FOR THE STOCKROOM, USE WATTSTOPPER MODEL 41:W1-200, EXISTING EXTERIOR LIGHTING TO REMAIN CONNECTED TO LANDLORDS HOUSE PANEL, ALL EXIT SIGNS AND SALES AREA EMERGENCY LIGHTS TO BE CONNECTED TO CIRCUIT LP -20, WIRING NOT SHOWN FOR DRAWING CLARITY, TYPE "J" FIXTURES ARE TO BE CENTERED BETWEEN EACH WALL STANDARD, THE LAMPHOLDER ASSEMBLY IS TO BE ANGLED BACK TO THE WALL AND AIMED AT THE CENTER OF THE 4'-O" x 41 -0" DECORATIVE WALL PANEL BELOW, ALL PROCESSING ROOM LIGHT FIXTURES AND OTHER NOTED FIXTURES TO BE SUSPENDED FROM ROOF DECK (UNLESS NOTED OTHERWISE) AT 121 -0" AFF, COORDINATE ON -SITE WITH LIFEWAY REPRESENTATIVE, SECURE THIS FIXTURE TIGHT TO ROOF DECK, a PROVIDE AND INSTALL A LIGHTING CONTROL PANEL (LCP) FOR CONTROL OF THE LIGHTING AND SIGN CIRCUITS, THE LCP SHALL BE A COOPER GREENGATE LITEKEEPER 16 (OR EQUIVALENT) WITH THREE S- BUTTON DIGITAL INPUT SWITCHES (DIGITA 5), THE LCP SHALL PROVIDE AUTOMATIC CONTROL OF THE LIGHTING AND SIGN CIRCUITS WITH THE DIGITAL SWITCHES PROVIDING MANUAL OVERRIDE (2 HOUR MAXIMUM) FOR ANY CIRCUIT, THE SYSTEM SHALL BE INSTALLED TO MEET THE WASHINGTON STATE ENERGY CODE REQUIREMENTS, PROVIDE COMMISSIONING OF THE THE LIGHTING CONTROL SYSTEM AND ALL OCCUPANCY SENSORS PER SECTION 1513,7 OF THE WASHINGTON STATE ENERGY CODE. JUNCTION BOX FOR ELECTRICAL WIRING TO CORNICE LIGI -ITING TO BE LOCATED AT END OF CORNICE SECTION(S), NOT IN MIDDLE OF THE RUN, FLEX CONDUIT TO BE CONCEALED FROM PUBLIC VIEW, COVER PLATE AND EXPOSED FLEX CONDUIT TO BE PAINTED SAME COLOR AS WALL TO BLEND IN AS MUCH AS POSSIBLE AT ALL LOCATIONS, COIN ICE L. IGHT ING DETA IL - CONIDU IT LQC4T ION SCALE: NONE CORN ICE LAMP SHOULD BE MOUNTED TO BACK SIDE OF CORNICE RE ER TO ARCHITECTURAL DETAILS FOR EXACT CORNICE CONFIGURATION, SEE DETAIL 2, SHEET A -5 AND DETAIL 11, SHEET A -9 CORN ICE L ICI --IT ING DETA 4L - TYPE 'F' F IXTUIRES SCALE: NONE CIRCUIT CONTINUED STOCKROOM OF N _SCALE; I /4 " =1' -O" NORTH CIRCUIT CONTINUED FROM STOCKROOM WALL STANDARD (TYPICAL) *ACT AT °i' -O" AFF 0 A B AGT AT cf '_o" AFF-$- •AGT AT cI' -O" ,FF OF N _SCALE; I /4 " =1' -O" NORTH CIRCUIT CONTINUED FROM STOCKROOM WALL STANDARD (TYPICAL) L EREAKROO ,I6HT \6 PAN SCALE: I/4 "= I' -O" v NORTH HIH.A -1 1d1 611 J — REVIEWED FOR-1 E COMPLIANCE *SPA 70 JUN 0 4 21 jttyOfTukwIIa TYPE "J" FIXTURES ARE TO BE 6" FROM WALL AND CENTERED BETWEEN EACH WALL STANDARD, THE LAMPHOLDER ASSEMBLY I5 TO BE ANGLED BACK TO TI-4E WALL AND AIMED AT THE CENTER OF THE 4' -o" x 4' -0" DECORATIVE WALL PANEL BELOW, FI> T(AE J T FICAL IN T4L ATION DETAIL._ RECEIVES 1 1I JUN 0120U PERMIT CEN SCALE: NONE 0 0 E cn 0 0 r- Q 0 L. 0 a) 0 a) U /3 CD CO > N mr,N N 0 N Q - N N u) c O N N L 7 z 622 -6883 0) LL 444,110011111111100114n iiiiiiiiiiiiiiiiiiiiii 9A It ;#) MI CC 0 Nisi ect . v isii.4 V Aa, NT E3U IL OUT ILI 1- LLJ LLJ C.) w 4 rga z 0 z LIGHTING PLAN 0 AGT AT cf '_o" AFF-$- L EREAKROO ,I6HT \6 PAN SCALE: I/4 "= I' -O" v NORTH HIH.A -1 1d1 611 J — REVIEWED FOR-1 E COMPLIANCE *SPA 70 JUN 0 4 21 jttyOfTukwIIa TYPE "J" FIXTURES ARE TO BE 6" FROM WALL AND CENTERED BETWEEN EACH WALL STANDARD, THE LAMPHOLDER ASSEMBLY I5 TO BE ANGLED BACK TO TI-4E WALL AND AIMED AT THE CENTER OF THE 4' -o" x 4' -0" DECORATIVE WALL PANEL BELOW, FI> T(AE J T FICAL IN T4L ATION DETAIL._ RECEIVES 1 1I JUN 0120U PERMIT CEN SCALE: NONE 0 0 E cn 0 0 r- Q 0 L. 0 a) 0 a) U /3 CD CO > N mr,N N 0 N Q - N N u) c O N N L 7 z 622 -6883 0) LL 444,110011111111100114n iiiiiiiiiiiiiiiiiiiiii 9A It ;#) MI CC 0 Nisi ect . v isii.4 V Aa, NT E3U IL OUT ILI 1- LLJ LLJ C.) w 4 rga z 0 z LIGHTING PLAN PANEL SCHEDULE PANEL SCHEDULE PANEL NUMBER: LOCATION: LP STOCKROOM LO,CAllON : STOCKROOM DIRECTORY O z c. DIRECTORY DIRECTORY EXISTING RTU -3 (HACR) SALES AREA LIGHTS (LCA) 1 3 2013 5 7 2011 9.46 9.46 9.46 2 45/3 4 EXISTING RTU -1 (HACR) 6 9.46 8 SALES AREA LIGHTS (LCA) 9 2011 3.71 EXISTING TRANSFORMER 'T1' SPARE LTG - STOCK /TOILET /E -FANS & MEZZANINE 9.46 45/3 10 EXISTING RTU -2 (HACR) REAR SIGN (TC) REAR SIGN (TC) FRONT SIGN (TC) FRONT SIGN (TC) R - DRINKING FOUNTAIN 13.13 70/3 12.60 11.25 17 20/1 0.00 19 20/1 1.83 9.46 12 6.67 6.67 35/3 6.67 14 16 18 EXISTING RTU-4 (HACR) R - SALES AREA HAND DRYER - WOMEN'S TOILET O z 1-- 0 1 3 5 w J O < 20/1 7 9 w J 0 kW kW 20/1 20/1 20/1 20/1 1.00 1.50 O z I < 0 20/1 2 DIRECTORY 1.00 1.68 20/1 4 1.00 • 0.36 20/1 6 1.00 0.90 20/1 8 0.50 0.30 20/1 10 11 20/1 0.54 SALES AREA TRACK LIGHTS (LCB) 1.00 20/1 20 * EXITS & SALES AREA EMERGENCY LI ogi MAIN BREAKER: M.L.O. MAIN BUS VOLTAGE: NOTES: 225A 480Y277 kW PHASE "A" kW PHASE "B° kW PHASE "C" 47.77 44.74 42.91 AIC: MATCH EXISTING FRAME: TRIP: TOTAL kW 135.42 MOUNTING: SURFACE *PROVIDE CIRCUIT BREAKER WITH A MEANS OF BEING LOCKED R - SALES AREA R - DEDICATED SERVER QUAD k WATER HEATER R - SALES AREA TELEVISIONS R - STOCKROOM R - SALES AREA 13 15 20/1 20/1 1.80 0.90 SALES AREA TRACK LIGHTS (LCB) SALES AREA TRACK LIGHTS (LCB) 17 19 21 23 25 27 29 31 20/1 0.72 20/1 12 0.90 20/1 14 1.20 1 20/1 16 0.54 • 0.72 20/1 18 20/1 20/1 20/1 20/1 0.36 2.00 0.36 1.08 • 0.36 0.36 20/1 20/1 0.90 20/1 0.18 1 20/1 SALES AREA TRACK LIGHTS (LCB) SALES AREA TRACK LIGHTS (LCB) SALES AREA TRACK LIGHTS (LCB) SALES AREA TRACK LIGHTS (LCB) SALES AREA TRACK LIGHTS (LCB) 33 35 20/1 20/1 20/1 20/1 20/1 37 20/1 0.72 0.72 0.65 1.65 1.20 1.20 • 20/1 R - REFRIGERATOR R - BREAK COUNTER 1 MICROWAVE R - BREAKROOM R - SALES AREA DOOR CHIME SYSTEM R - MANAGER'S OFFICE R - SALES AREA STOREFRONT SALES AREA CORNICE LIGHTING (LCB) R - P.O.S. 20 R - TOILETS 22 R - SERVER CABINET AREA 24 R - SALES AREA FEATURE WALLS • 0.54 20/1 0118 20/1 32 0.72 20/1 34 26 R - EAS LOSS PREVENTION 28 R - BACK COUNTER, OPEN SIGN 30 R - MUSIC RACKS 1.50 0.72 0.72 R -STAR MUSIC SYSTEM QUAD @ TELEPHONE BACKBOARD 36 R - ROOFTOP 38 39 20/1 1.20 0.10 40 R - GENERAL OFFICE LIGHTING CONTROL PANEL 42 HAND DRYER - MEN'S TOILET PROVIDE MELAMINE SHELF, 16 "W x 36 "L, WITH TWO NERVY -DUTY SHELF BRACKETS FOR COMPUTER BOARD, COORDINATE PLACEMENT WITH LIFEWAY EQUIPMENT CONTRACTOR AT TIME OF TELEPHONE AND COMPUTER INSTALLATION, 2" CONDUIT SECURED To WALL ABOVE EQUIPMENT BOARD 3' -0" x 3' -O" EQUIPMENT 4 COMPUTER BOARD DEDICATED QUAD OUTLET AT TOP OF BOARD (5' -6" A.F.F.) COMFUTE C 74 SCALE NONE M d IN BREAKER: MIN BLS: VOLTAGE: 150A 150A NOTES: R = RECEPTACLE LOAD 208Y120 kW PHASE "A" kW PHASE "B" kW PHASE "C" MATCH EXISTING FRAME: TOTAL kW TRIP: MOUNTING: SURFACE *PROVIDE CIRCUIT BREAKER WITH A MEANS OF BEING LOCKED 2" CONDUIT SECURED To WALL ABOvE TELEPHONE BOARD QUAD OUTLET loo 100 4'-0" x S' -O" TELEPHONE BACKBOARD OCR 00 RP -34 QUAD OUT_E-r TIP OF DOOR FRAME TFLE9 -ONE EQUIPMENT 0A SCALE= NONE LIGHTING CONTROL PANEL CIRCUITS. SEE LIGHTING PLAN AND NOTE S ON SHEET E -2, LOP OUTPUT # AREA /CIRCUIT /DEVICE SERVED ZONE 1 DAYL IGHT ING 1 1 2 SALES I 2 3 SALES 2 3 4 SALES 3 2 5 SALES 4 2 6 SALES 5 3 7 SALES 6 3 S SALES 7 3 9 SALES S 3 10 SALES 9 4 II DAYLI61 -ITING 2 1 12 DAYLIGHTING 3 1 13 SIGNI 5 14 SIGN 2 5 15 SIGN 3 5 16 SIGN 5 ING CONT OL PANEL SCALE- NONE EXISTING GENT AL \QTES AND SPEC IFIC4TIONS A, BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK, THEREFORE, IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL EXISTING SITE CONDITIONS INCLUDING BUT NOT LIMITED TO, SERVICE LOCATIONS, TRANSFORMERS, SERVICE LAYOUTS, RISER LOCATIONS SERVING THE SPACE, STUB -UPS, TEMPORARY UTILITY LOCATIONS AND TELEPHONE LOCATION TO ENSURE THE INTENT OF TI-4E PLANS IS NOT DEVIATED FROM, CT BOXES, STUB -UPS, SECONDARY POWER CONDUIT AND TELEPHONE SERVICE CONDUITS ROUTING AND LOCATIONS SHOWN ON THESE DRAWINGS ARE FOR REFERENCE ONLY, ACTUAL ROUTING AND TERMINATION POINTS SHALL BE VERIFIED AND COORDINATED DURING SITE VISIT PRIOR TO BID AND START OF WORK, THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE, LATER CLAIMS FOR ADDITIONAL LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR ANY DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED, COORDINATE WITH OTHER TRADES AND CONTRACTORS INVOLVED IN THE PROJECT FOR ItEMS IN THEIR SCOPE OF WORK W1-1101-1 REQUIRE ELECTRICAL WORK ( DISCONNECTION, RECONNECTION, ETC,) AND ARE NOT INDICATED ON THE ELECTRICAL DRAWINGS, THIS NOTE APPLYS to ALL SHEETS, B, GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE. C. COMPLY WITH THE NEC, STATE, AND LOCAL CODES, D. USE ONLY COPPER CONDUCTORS, AS NOTED. MINIMUM SIZE #12 A. USE TYPE THWN, UON, ALL CIRCUITS SHALL BE COLOR CODED, E. MC CABLE MAY BE USED WHERE ALLOWED BY NEC AND LOCAL AUTHORITY HAVING JURISDICTION, WHERE CONDUIT IS REQUIRED, USE 1/2" MINIMUM. USE EMT WHERE CONCEALED IN WALLS AND /OR CEILINGS AND RIGID IN SLAB AND UNDERGROUND, F, USE IVORY DEVICE COVERPLATES, UON, CONTRACTOR SHALL VERIFY COLOR REQUIREMENTS WITH OWNERS REPRESENTATIVE, G, NOT USED IN LANDLORD DRAWING PACKAGE. H. ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED, COMMERCIAL GRADE, I. USE HUBBELL WIRING DEVICES AS FOLLOWS= SWITCHES - 15 AMP, #1201 -I, 1202 -1, 1203 -1 RECEPTACLES - 15 AMP, #5252 -I, 5262 -I FOR GENERAL PURPOSES. J. K. L. M. N, 0, P, USE 6 FEET MAXIMUM LENGTH OF FLEXIBLE CONDUIT TO FIXTURES. FLUORESCENT FIXTURES SHALL HAVE HOLD DOWN CLIPS, VERIFY AND ADD TO EXISTING TROFFERS AS NECESSARY. REMOVE TEMPORARY WIRING UPON COMPLETION of WORK, REMOVE ALL UNUSED EXISTING WIRING UPON COMPLETION OF WORK, INCANDESCENT FIXTURES SHALL HAVE 150 DEGREES C WIRING FROM OUTLET BOX TO LAMPHOLDERS. INCANDESCENT LAMPS ARE 130V, INSIDE FROSTED, UON, VERIFY LOCATION OF EXISTING PANELBOARDS AND SWITCHES WITH OWNER'S REPRESENTATIVE, DO NOT INSTALL MORE CONDUCTORS N A BRANCH CIRCUIT HOMERUN T1-IAN SHOWN, ALL WORK SHALL BE COORDINATED WITH OWNERS REPRESENTATIVE AS NECESSARY. R, ELECTRICAL DRAWINGS ARE DIAGRAMMATIC EXCEPT FOR DETAILS AND ELEVATIONS. DO NOT SCALE FROM DIAGRAMMATIC DRAWINGS, EXACT LOCATIONS OF DEVICES AND PANELS ARE TO BE DETERMINED AND ROUGHED -IN DURING CONSTRUCTION TO AVOID INTERFERENCE, TO MEET USER REQUIREMENT. S, VERIFY EXACT LOCATION OF ALL MOTORS AND EQUIPMENT BEFORE ROUGHING IN, T. BACK To BACK MOUNTING OF RECEPTACLES IS NOT PERMITTED, U, MINIMUM 1-101RIZONTAL SEPARATION BETWEEN BOXES ON OPPOSITE WALLS OF FIRE RATED WALL SHALL BE 24 INCHES, V, CONTRACTOR SHALL CUT AS REQUIRED TO INSTALL ELECTRICAL EQUIPMENT, REPAIR OF FLOOR OR WALLS SHALL BE COORDINATED WITH GENERAL CONTRACTOR, CONTRACTOR SHALL ALSO REPAIR ALL OPENINGS LEFT DUE TO EQUIPME REMOVAL, W. CONDUCTORS ARE AWG #12 COPPER UNLESS OTHERWISE SHOWN, ALL CONDUCTORS LARGER THAN #10 SHALL BE STRAN RUNS IN EXCESS OF 90' -O" (ONE WAY) SHALL BE SIZED PER THE NATIONAL ELECTRICAL CODE MAXIMUM 2 % VOLTAGE DROP, X. PANELBOARDS SHALL CONTAIN A TYPEWRITTEN DIRECTORY WITH A PLASTIC COVER AFFIXED TO THE INSIDE DOOR. Y. ALL FIXTURES, DEVICES, CONDUIT, AND EQUIPMENT SHALL BE SECURED WITH APPROVED HANGERS AND ANCHORS AND IN ACCORDANCE WITH APPROVED STANDARDS OF INSTALLATION. Z. COORDINATE WORK IN CONJUNCTION WITH LIFEWAY PROJECT MANUAL DIVISION ONE, DIVISION THREE, AND DIVISION 16, AA, ALL FLOOR CUTS AND TRENCHING FOR UNDERGROUND ELECTRICAL AND LOW VOLTAGE CABLING TO BE WET SAW CUT AND MANUALLY REMOVED. NO JACK HAMMERING ALLOWED. REVIEW) FOR I E COMPLIANCE JUN p 4 2009 E u !-� D. I" BB, CONTRACTOR TO V 1S IT SITE TO DETERMINE IF THERE IS A FIRE ALARM SYSTEM REQUIRED AND INCLUDE IN BID PACKAGE AS NECESSARY CC. ELECTRICIAN TO PROVIDE BUS BAR AT PHONE BOARD, COORDINATE WITH LIFEWAY, DD, ELECTRICIAN IS RESPONSIBLE FOR OBTAINING A LOW - VOLTAGE WIRING PERMIT IF REQUIRED ON BEHALF OF THE OWNER AND HIS INSTALLER AND WILL COORDINATE WITH LIFEWAY PROJECT MANAGER AS NECESSARY, EE, THE LANDLORD DOES NOT PROVIDE TEMPORARY UTILITIES. CONTRACTOR MUST COORDINATE WITH THE LOCAL UTILITY COMPANIES TO SET METER FOR TEMPORARY WATER AND POWER DURING UPFIT CONSTRUCTION, SHOULD THE LANDLORD DETERMINE THAT THE CONTRACTOR IS USING WATER AND POWER FROM THE LANDLORD, THE CONTRACTOR WILL BE BILLED FOR THE CONSUMPTION. FF, COMBINATION POWER /COMMUNICATIONS FLOOR BOXES= WALKER S8OCS2 -1 WITH (1) 827E3 BRASS FLANGE, (I) 8238 BRASS RECEPTACLE PLATE, AND (1) S29STC BRASS COMMUNICATION PLATE. EXTEND (I) 1 -1/2" CONDUIT MINIMUM WITH PULL STRING FROM COMMUNICATION COMPARTMENT TO ACCESSIBLE LOCATION ABOVE CEILING AND TERMINATE WITH BUSHING, PROVIDE VAPOR BARRIER AROUND FLOOR BOX, POWER FLOOR BOXES: WALKER BSOCS1 -1 WITH (I) 8178 BRASS FLANGE, (1) 8208 RECEPTACLE PLATE, EXTEND CONDUIT TO SCCESSIBLE LOCATION ABOVE CEILING AND TERMINATE IN JUNCTION BOX, PROVIDE VAPOR BARRIER AROUND FLOOR BOX, INTERIOR 1 -1 !EXISTING SOkVA 1 1 TRANSFORMER 1 J 111.111 L. r - L4SOV =208Y12O J- L_ EXISTIN 20SY120 15OA MCB EXISTING 1 EXISTING LP 480Y277 225A MLO LCP (LIGHING CONTROL PANEL) EXTEND EXISTING FEED FROM 2004 DISCONNECT TO PANEL 'LP'. ENSURE CIRCUIT IS 2"C, (4) #3/0 4 (1) #6G LANDLORD'S METER ROOM LANDLORD'S DISTRIBUTION EXISTING r,(7,-1 200A METER BASE BY - -1 L_ °J LANDLORD I� 1"15E IA AM NOT To SCALE 1 EXISTING 600V, 200A DISCONNECT, FUSED 2004 TRACK LIGHTING ABOVE P,o,S, TO BE MOUNTED DIRECTLY ABOVE CUSTOMER AREA AT EACH P,O,S, UNIT, LIGHT FIXTURES ARE TO BE INSTALLED AFTER P.O,S, UNITS ARE SET. FLAN VIEW P.O.S. COUNTER BOTTOM OF SHADE 3S" ABOVE COUNTERTOP ELEV4T ION VIEW PENDANT LIGHTS TO BE CENTERED ABOVE CUSTOMER AREA DETAIL - F,0,5, PENDANT - I I1 I I F IXTU E SCALE- NONE RECEIVED JUN 012009 PERMIT CENTEI- 0 Q. 0 w a) 0 0 E 0 a) 0 0 cll 0 0 0 r -4-, 0 L. 0 o 622 -6883 rn N !Fix!' 1111111111 % /Iflli li1ff111111111�11111111111r 0P D Gr ti 40287 I0, li,1r;VS' CHRISTIAN STORES Biblical Soluti 0 0 2 Q LLI LLJ LLI CL 12 0 z 0 0 SCHEDULES, NOTES, DETAILS ��3