Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL09-0355 - ARCO AM/PM NO 83098
ARCO AM /PM 5800 SOUTHCENTER BL ELO9-03 55 City0f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1157200352 Address: 5800 SOUTHCENTER BL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL09 -0355 Issue Date: 10/08/2009 Permit Expires On: 04/06/2010 Tenant: Name: ARCO AM /PM NO 83098 Address: 5800 SOUTHCENTER BL , TUKWILA WA Owner: Name: YAMASHITA SUSIE Phone: Address: YOSHINO INC , 5800 SOUTHCENTER BLVD Contact Person: Name: ALEXIA INIGUES Phone: 425 251 -6222 Address: 18215 72 AV S , KENT WA Contractor: Name: RAINBOW ELECTRIC INC Address: N 809 NAPA , PO BOX 4445 Contractor License No: RAINBEI171KR Phone: 99202 Expiration Date: 06/02/2011 DESCRIPTION OF WORK: ELECTRICAL WORK FOR REMODEL Value of Electrical: NRES: $15,000.00 RES: $0.00 Type of Fire Protection: NO Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: 2008 Date: $477.50 (O- 1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction • r the performance of work. I am authorized to sign and obtain this electrical permit. Signature:0— Date: tO - 8 -0 9 Print Name: 1 1 �'� C9C-1 v 2CI This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0355 Printed: 10 -08 -2009 Parcel No.: 1157200352 Address: Suite No: Tenant: d • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5800 SOUTHCENTER BL TUKW ARCO AM /PM NO 83098 PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL09 -0355 ISSUED 06/08/2009 10/08/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: �� 9k Date: doc: Cond -Elec EL09 -0355 Printed: 10 -08 -2009 CITY OF TUKWIL Community Development Department Permit _Center 6300 Sbuth ntfBWd Suite 106 Tukwila, WA 98188 httc•://wwW.ci.tukwila.wa.'ut Electrical Permit No. iytiiii Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be rcomplete 'in order th be ,'ateepted for ,plan 'review, ApiptiEntiori§ will not be accepted through the ffiil or by fax, **Please Print** SITE LOCATION , King Co- Ssessbr's TAR N-0 _115720-0352 Site Address; _ _ 5800 Southcenter Boulevard, TUKWila, WA 98188 Tenant Name: ARCO AM/PM Facility No. 83098 Property Owners Name: BP West Coast Products LLC mailing Addregg' 4 Conterpointe Drive 'Suite Number: FlOor_ _ New Teat fl - Yes 0 .. NO L8 Palma CA 90623 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Nathe, Alexia Inigues, Barghausen Consulting Engineers, Inc. Mailing Address: 18215 - 72nd Avenue South E-Mail Address: ainigues barghausen:coit Day Telephone: (425) 251-6222 Kent WA 98032 City Fa NiiTribEr State (425) 251-8782 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name- Mailing Address: Contact Persons _ E=Mail Address: Contractor Registration Number_ i y Day Telephone: FaX NitfrIber Expiration Date: State Zip , Valuation of Project (contraetor's bid price): $ 15000 Seope of Work (please provide detailed information): IDI t1 VYIPS TO e _ tui 7-7- 'FOR 1-Del,_=th _OreiLuffiret Will service be 'altd? 21 Yes El No Adding More than SO aftii30 YeR NO Type of Use: existing convenience store and gas ttatiOn Type of work: ▪ New 11:1 Addition [3 Service Change El Remodel 0 Tenant Ititpi-bileiliditt • Low Voltage Li Generator ID Fire Alarm El Telecommunication ID Temporary Service Property Served by Vi Puget Sound Energy LI Seattle City Light 11-n'Ori Lula\ I-N)0§- Eioatie51.Peern'itlApplicatiowdoc bh Page 1 bf 2 1975.032 . ncif ("Inc RESIDENTIAL W NEW- RESIDENTIAL SERVICE ❑ Ncw single "family dwellings - - - -- 5145.60 (including an attached garage) • Garages, pools, spas and outbuildings $78.66'ea ❑ Low voltage systems (alarm, furnace' thermostat) -- - - - -- $57,00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits - -- -- $78.00 number of added circuits— $11.00 ea ❑ Circuits added/altered without service change -$52 ,00 (up to 5 circuits) ❑ Circuits added/altered without service change - $52.00 (6 or more circuits) -- $7.30 ea ❑ Meter /mast repair - - $65 -00 ❑ Low voltage 'systems $57:00 (alarm, furnace thermostat) MULTI- FAMILY_AND COMMERCIAL Fees are based on the valuation of the electrical cotltl'act: MISCELLANEOUS FEES ▪ Temporary service (residential) $60:00 0 Temporary service (generator) - - $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals. $75.00 Number of concessions $`10.00 ca PERMIT APPLICATION NOTES - Value of Construction In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Re -view = Applications for which no permit i"s issued Withiii 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING_OWNER OR ELECTRICAL CONTRACTOR: rep to /56( Signature: Date: Print Name: Day Telephone: Mailing Address: IDate Application Accepted: City State Zip Date Application Expires: t ?-tcCv f t2 1 Staff Initials: H:\ Applications\Forms=Applications On Line \1 -2009 - Electrical Permit- Application.doc bh Page 2 of 2 1975. 032.13df.do 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 1157200352 Permit Number: EL09 -0355 Address: 5800 SOUTHCENTER BL TUKW Status: APPROVED Suite No: Applied Date: 06/08/2009 Applicant: ARCO AM /PM NO 83098 Issue Date: Receipt No.: R09 -01572 Payment Amount: $477.50 Initials: WER Payment Date: 10/08/2009 01:41 PM User ID: 1655 Balance: $0.00 Payee: RENE S GARZA TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC - Authorization No. 09651B ACCOUNT ITEM LIST: Description 477.50 Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 394.00 000.345.832.00.00 83.50 Total: $477.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 10 -08 -2009 INSPECTION RECORD !, � ' ��7� Retain a copy with permit (�, INSPECTION NO. P MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 4.1c0 �P Type of Inspection: 2.100 7Address: 05 0-C• L. Date Called: Special Instructions: Date Wanted: r , a:r Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: _ 01(.6c-T1 (45 tierPE D �! 1 Date: 1 1113/07 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: r Receipt No.: Date: INSPECTION RECORD�cd Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ve-- 6300 Southcenter Blvd., #j 00, Tukwila, WA 98188 (206)431 -3670 Project: j� �,r`� 44.1 ]pi [/ Type of Inspection: lop AddressOq Date Called: Special Instructions: Date Wanted: ! f !i ! a.m. p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: t -- 14r-CA #10. EArB€ ewe( atI1 gep t oa 14 • VJ . 6!- "to a T - (Fi aovkae9 Fes, ouTher 4� Date: I l 12- 4 1 ❑ $60.00 REIN PECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION RECORD fo ' 05 Retain a copy with permit G INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 9--- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Projectr_ % ?ri I Type of Inspection: 7003 Address:v� `, .] • &1.— • Date Called: Special Instructions: Date Wanted: /' cai.t.... m. Requester: Phone No: XApproved per applicable codes. 0 Corrections required prior to approval. /u COMMENTS: 0.064,14 14 lifili-74Aj Date: 1,' 2 J ❑ $60.00 REINS CTION FEE REQ IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPE ' ON NO. MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: /ice co p _e / pi �,�j'� Type of Inspection: 704 Address Date Called: Special Instructions: Date Wanted: r t D cii, Requester: Phone No: I I Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: �-r a 1 1■Ulk C0-4 \ OUP r tai KM--164 Date: 11 o5 /07 ❑ $60.00 REINSPEC ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION RECORD 035 Retain a copy with permit INSPECTION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proj t; co Am jp � d o 13011 Type of Inspection: 700 ' Address- 61;700 SZ. gL. Date Called: d Special Instructions: Date Wanted: 10 3v P.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Oii - Un17fR4¢o.149 6t..4IP TO i-loT Bcy Inspector: Date: (0/30 M, $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD W /A_ 3 5 S INSPECTION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION Retain a copy with permit £ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project31 _ 02 All Pil /sTL'g Type of Inspection: 7 3 \—)4 Address Date Called: OK - Coil els jTo1 19017 A4D Special Instructions: Date Wanted: /0 // 'Y a.m. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: \—)4 OK - Coil els jTo1 19017 A4D I- 4L L-It - C b6 eoud tth -ELI j� - Kt1TC \&J W - c,oK(tbok 1.44-14., Inspector: r� Date: / vfr /07 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit £�7. 035 INSPE ION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206431 -3670 Project: 4c, _ CO Aiifp Type of Inspection: 700/ 700, Address: Date Called: Special Instructions: Date Wanted: /p�rZ AA < ° f Requester: Phone No: EiApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: vp, boos ONI C 5L-' 60AJburf Ta f Loot B02 (AMU./ CVY 6 AT Cork-6/ A-Nip 14651- 9TeR(oK UlAw I rvr+ Date: /0 1Z 09 1 ri $60.00 REINSPECTION FEE EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ,.� • aStr ' •• P'4 6-a E!i. w _ • ...c..� 410 PERMIT COORD COPY 411 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL09 -0355 DATE: 07 -08 -09 PROJECT NAME: ARCO AM/PM SITE ADDRESS: 5800 SOUTHCENTER BL Original Plan Submittal Response to Incomplete Lettr # Olfermit Response to Correction Letter # X Revision # 1 Issued DEPARTMENTS: 01" "6e Bul ding Division Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator U n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07-09-09 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route t Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions ❑ DUE DATE: 08-06-09 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documenls/rouling slip doc 2 -28 -02 M� PERMIT COORD COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL09 -0355 DATE: 06 -09 -09 PROJECT NAME: ARCO AM /PM SITE ADDRESS: 5800 SOUTHCENTER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: C BuiTling Division Public Works tic-01 Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 06-11-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 07-09-09 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. -71 Date: g/ 0,00 1 Plan Check/Permit Number: ❑ Response to Incomplete Letter # Response to Correction Letter # b ve Revision # Permit is Issued El Revision requested by a City Building Inspector or Plans Examiner - aj Project Name: Project Address: AP-CO A-M 1M (6(7O Soot l u n-}e Contact Person: , A- I &Y / a- rn j 9`Le S Summary of Revision: Jo4 1✓1 res p oose 0 Ps .0- J!O(7S ©upsj Yt ©.-f rt (AV biAdi /&_ — Pl a 1'00 s I'or) RSVED CITY OF TtikwitA IJUL 0 8 2009 PERMIT CENTER Phone Number: yap - (6(o oeer Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 17 Oc \applications\forms - applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Untitled Page 0 1 Page 1 of 2 Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company RAINBOW ELECTRIC INC 5095343030 N 809 NAPA PO BOX 4445 SPOKANE WA 99202 SPOKANE Corporation UBI No. Status 600488161 ACTIVE License No. RAINBEI171KR License Type ELECTRICAL CONTRACTOR Effective Date 5/19/1983 Expiration Date 6/2/2011 Suspend Date Specialty 1 GENERAL Specialty 2 UNUSED MASTER ELECTRICIAN INFORMATION License ANDERW0962KL Name ANDERSON, WILLIAM 0 III Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date LIBBY, WALLACE W Cancel Date 01/01/1980 Bond Amount BAST, JEFF 4 01/01/1980 105129820 ANDERSON, WILLIAN III Until Cancelled 01/01/1980 SOLBERG, GARY 04/02/2009 01/01/1980 LIBBY, WALLACE W AGENT 01/01/1980 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 TRAVELERS CAS Et 105129820 04/01/2009 Until Cancelled $4,000.00 04/02/2009 https://fortress.wa.gov/lni/bbip/Detail.aspx 10/08/2009 S64'26'45 "E 104.85' gr,WWWWWWWIM, \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\ \\\\\ \\\\\\\\\ \ \ \\\\\\\\\\\\\ \\ \ \ \ \ \\\\\\ \\N\\\\\\\\\ \\\ \ o\\\\\ \ \\\\\\ \ \ \A\N A \ \\ \\ y\\ AM\ \\ \\\\\\\\ e\\\\\\\\\\\\\\\\\\\\\\\\\\ \\\\\\ \ \ \ \ \ \\ \\\\\ \ \\\\\\\O\\\i `I EXISTING PARKING EXISTING PARKING EXISTING PARKING ±58' -0" TO NEW ADDITION 26SF ADDITION TO ACCOMMODATE NEW UNISEX ACCESSIBLE RESTROOM NEW EXHAUST FAN PROVIDE (2) 6" GUARD POSTS. MATCH EXISTING 10 20 40 EXISTING OFFICE EX4STtNG REST ROOM EXISRRNG BA K RO M NISEX RESTROOM EXISTING SALES ROOM N w N Z HOT FOOD EXISTING PROGRAM SALES ROOM EREMODEL INTERIOR OF EXISTING CONVENIENCE STORE REPAINT EXTERIOR REPLACE SIGN XISTING COOLER REPAINT DIRECTIONAL ARROWS. TYPICAL EXPAND SALES AREA INTO EXISTING COVERED PORCH AREA EXISTING ADA RAMP 0 REPLACE EXISTING SIGN W/ NEW 0 RESTRIPE /PAINT EXISTING ACCESSIBLE PARKING STALL (AND PATH) REFER TO AS 1.2 EXISTING PIC UNIT, COLUMN MTD. EXISTING UNDERGROUND STORAGE TANKS • EXISTING CANOPY TO REMAIN. PROVIDE NEW GRAPHICS EXISTING PIC UNIT, COLUMN MTD. EXISTING DRIVEWAY EXISTING PLANTER' EXISTING DRIVEWAY e =1.36' 16" R=565 • .65' L= 158.49' N65'50'45"W 5.01' SOUTHCENTER BOULEVARD � r' V /C /NTY MAP SITE DATA ADDRESS: 5800 SOUTHCENTER BLVD. TUKWILA, WASHINGTON OWNER: BP WEST COAST PRODUCTS, LLC 4 CENTERPOINTE LA PALMA, CA LOT SIZE: 18,593 SQUARE FEET APN• 1157200352 ZONING: RCM (REGIONAL COMMERCIAL MIXED —USE) BUILDING AREA: 1,811.4 SQUARE FEET (EXISTING) 26 SQUARE FEET ADDITION TO STORE 1,500 SF (CANOPY) CONSTRUCTION TYPE: II —B NON — SPRINKLERED (STORE); II —B (CANOPY) OCCUPANCY: M (STORE AND GAS) HEIGHT: EXISTING ±18' SCOPE OF WORK FIE COPY Permit No., .O3— Q353 Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approvedld and conditions is acknowledged: BY v Date: City Of iUkwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. TENANT IMPROVEMENT TO EXISTING STORE INTERIOR CONSISTING, BUT NOT LIMITED TO: • DEMOLITION AND REPLACEMENT OF NON LOAD BEARING WALLS :NEW FLOOR FINISHES .LIGHTING IMPROVEMENTS NEW CABINETS & COUNTERTOPS NEW FOOD SERVICE EQUIPMENT NEW GONDOLAS NEW WALL FINISHES AND PAINTING UPDATE EXTERIOR SIGNS UPDATE EXTERIOR PAINT COLORS APPL/CABLE CODES 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL FIRE CODE 2006 UNIFORM PLUMBING CODE 2006 NATIONAL ELECTRICAL CODE 2006 INTERNATIONAL MECHANICAL CODE DRAWING INDEX DWG NO. AS1.1 SITE PLAN ARCHITECTURAL A.1.1 CONSTRUCTION FLOOR PLAN A.1.2 FLOOR FINISH PLAN A.1.3 REFLECTED CEILING PLAN A.2.0 EXTERIOR ELEVATIONS C —STORE & CANOPY REIMAGE A.2.3 INTERIOR ELEVATIONS . A..4 INTERIOR ELEVATIONS A.2.5 INTERIOR ELEVATIONS EQUIPMENT . Q1.1 EQUIPMENT PLAN Q2.1 EQUIPMENT SCHEDULE ELECTRICAL 0 E1.1 ELECTRICAL ROUGH —IN PLAN E1.2 ELECTRICAL FLOOR PLAN E1.3 ELECTRICAL DEMO /LIGHTING PLAN E1.4 ELECTIRCAL SCHEDULES & DIAGRAMS PLUMBING P.1.1 PLUMBING DEMOLITION /ROUGH —IN PLANS, NOTES, LEGENDS & DETAILS MECHANICAL M.1.1 MECHANICAL PLAN, SCHEDULES, NOTES & DETAILS SITE PLAN SCALE: 1"= 20' REVIEWED FOR :ODE COMPLIANCE NFPA70 - NEC JUN 16 2009 t yOfTukwila RIJLD1NGAIVISIO. iJ 161/01 (96 ECEIV D CITY R OF TU LA JUN 0 9 2009 PERMIT CENTER CONSUL TANTS GENERAL PROJECT NOTES A. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS. CONTRACTORS MUST COMPLY WITH CONTRACTOR REGISTRATION REQUIREMENTS OF ALL GOVERNING AUTHORITIES. THE GENERAL BUILDING PERMITS SHALL BE PAID FOR BY THE OWNER. ALL OTHER PERMITS SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE. ALL REQUIRED CITY, COUNTY AND /OR STATE LICENSES SHALL BE ACQUIRED AND PAID FOR BY THE INDIVIDUAL SUBCONTRACTOR. B. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION. CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF PLANS ON THE PREMISES IN GOOD CONDITION AT ALL TIMES. THIS SHALL INCLUDE ALL ADDENDA AND CHANGE ORDERS. C. DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS, DRAWINGS AND SPECIFICATIONS ARE NOT INTENDED. THE CONTRACTOR IS TO CLARIFY ANY SUCH DISCREPANCIES WITH THE ARCHITECT /CONSULTANT PRIOR TO COMMENCING WORK. D. STATED DIMENSIONS TAKE PRECEDENCE OVER GRAPHICS, DO NOT SCALE DRAWINGS TO DETERMINE LOCATIONS. THE ARCHITECT /CONSULTANT SHALL BE NOTIFIED OF ANY SUCH DISCREPANCIES PRIOR TO CONTINUING WITH WORK. E. GENERAL CONTRACTOR TO REFER TO THESE DOCUMENTS AS WELL AS SPECIFICATIONS FOR IDENTIFICATION OF ALL OWNER SUPPLIED ITEMS, ALL ITEMS NOT MARKED AS 'OWNER SUPPLIED' ARE TO BE SUPPLIED BY GENERAL CONTRACTOR. UNLESS NOTED OTHERWISE, ALL ITEMS ARE TO BE INSTALLED BY GENERAL CONTRACTOR. F. FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S APPROVED SHOP DRAWINGS /DATA SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. G. THE . CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE JOB IS IN PROGRESS AND UNTIL BUILDING IS OCCUPIED. H. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. I. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. J. CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER AND TOILET FACILITIES AS REQUIRED. K. GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, UNLOADING, UN— CRATING, INSTALLATION AND HOOKUP OF ALL FOOD SERVICE EQUIPMENT AND OTHER OWNER FURNISHED ITEMS. L. GENERAL CONTRACTOR IS REQUIRED TO LABEL ALL ELECTRICAL PANELS, PLUMBING VALVES, AND ROOF TOP EQUIPMENT. PLASTIC . PHENOLIC ENGRAVED PLATE SCREWED ON. M. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH ALL REQUIREMENTS OF THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY. N. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 0. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION. PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. P. MATERIALS LISTED IN DRAWINGS ARE BASED ON DESIGN INTENT. ALTERNATE SPECIFICATIONS MAY BE ACCEPTED PROVIDED THEY CLOSELY MATCH SPECIFIED MATERIAL. CONTRACTOR IS TO SUBMIT PROPOSED SAMPLES OF SUBSTITUTIONS, ALONG WITH SAMPLE OF THAT SPECIFIED IN DRAWINGS FOR REVIEW BY THE OWNER. Q. GC TO REFER TO BID DOCUMENT PACKET FOR OWNER'S SCOPE OF WORK. SAID DOCUMENT TAKES PRECEDENCE OVER ANY SCOPE THAT MAY BE PRESENTED IN THIS SET OF CONSTRUCTION DOCUMENTS OR SPECIFICATIONS. R. ALL WORK SHALL BE PERFORMED AS SHOWN ON THESE PLANS AND IN ACCORDANCE WITH "ARCO" STANDARD SPECIFICATIONS. S. WHERE LOCAL CODES, ORDINANCES OR REGULATIONS ARE MORE RESTRICTIVE THAN "ARCO'S" STANDARD SPECIFICATIONS, THEIR LOCAL REQUIREMENTS SHALL GOVERN. T. ANY DISCREPANCY BETWEEN FIELD CONDITIONS AND THESE PLANS ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER. NO WORK SHALL BE PERFORMED ON THE ITEMS IN QUESTION UNTIL DIRECTED BY THE OWNER. NOTE: BARGHAUSEN HAS NOT PERFORMED AN ADA SURVEY TO VERIFY THE EXISTING SITE AND STORE ACCESSIBILITY. CONTRACTOR TO CONFIRM LOCAL ACCESSIBILITY WITH INSPECTOR AS REQUIRED. CONTACT GLOBAL ALLIANCE PM OR FRANCHISE CONSULTANT TO GET COPY OF LAST SURVEY AND TO CONFIRM ALL NECESSARY UPGRADES FOR CONSENT DECREE HAVE BEEN PERFORMED. ARCHITECT /ENGINEER: CONTACTS: PLUMBING /MECHANICAL /ELECTRICAL: CONTACT: BARGHAUSEN CONSULTING ENGINEERS INC. 18205 72ND AVENUE S. KENT, WA 98032 DANIEL B. GOALWIN (425) 656 -7441 CARYL J. MATTSON (425) 656 -1063 SACRAMENTO ENGINEERING CONSULTANTS 10555 OLD PLACERVILLE ROAD SACRAMENTO, CA 95827 CHRIS GILLAND, (91 6) 368 -4468 CONFIDENTIALITY S TA TEMENT.• THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. CLIENT: bp , A , y O 43+�V'+ ,. 1riA Akiiiii.,. ARCO BP WEST COAST PRODUCTS, LLC . 14 A CaV s A: ' ' GAT V /"G ENG,NE 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. I DATE REVISION DESCRIPTION t� 05.26.09 PERMIT REVIEW - BP 2& 06.05.09 ISSUED FOR PERMIT - CITY A A A n Io 12 SEAL . kJ J(Se 0 VI ASy `. GP y Z 28527 O ( Fsj ,4• .s,, L \s\G\ O t,. A. III * CONFIDENTIAUTY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALUANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L&M - FULLERTON - SITE ADDRESS: 5800 SOUTHCENTER BLVD. • @ 1.5 . TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: ALLIANCE Z&DM: CMEQ(ED BY: BP REPM: DRAWN BY AWANCE PM: VERSION: . PROJECT NO, 1975.75 DRAWING TITLE: SITE 5 SHEET NO: AS 1 ■ 1 COMPUTER SYSTEM BECEPI_AI _+_,5_ -_ CARBON ATOR ECE�T_AL+24" _ -- ICED LATTE RECEPZAI 4" DUAL SOFT HEAT BREWER GEEL_A1 +.24"- -_ _ -- SINGLE SOFT HEAT STAND IMO DOUBLE SOFT HEAT STAND Z LATTESTEAMA ERA - RECEPT'S AT +18" CAPPUCCINO MAKER O EXISTING COVERED TRASH ENCLOSURE EOEe7. ------------ -- --- -- REACH—IN EF R G21C 1.. —±24✓}" ---- - - - - -- REACH— IN(FREEZER x EXISTING STORAGE CONTAINER x x x EXISTING ORAGE NEW UNISEX REST ROOM 3' -2" dr 3dr FREEZER REFRIGERATOR CI L = - - - - -= = - \-7-\ CON c1 O O HOOD CONTROL PANEL �2 5 TIER EXISTING OFFICE -r 511ER WATE ALt54' _ BOOSTER SAT 54'L COFFEE TIME TG10B 4" VEN AL±24" TGB HEESE DISP I r 1 I DI BEER SPLAY I L J T�rI —____ -11 - BUN EP AS. 4$" TG6 PRIMARY SODA 11_._ - -. s_Q z 0 u (Al :i z PRC MO 1 EXISTING SALES AREA BULK 0 z CJ s 0 PROMO III 2/MVE STUB UP (5) -1" & (1) -3/4" CONDUITS +6" FOR RECEPTS IN TRANSACTION COUNTER • • I r 1 3 2 4 EXISTING PREFAB OOLER 711 3 CANDY 3• JERKY DEPT. ET ASE C6A IN CABINET BASE ��� �. LOTTO TERMINAL ^,-'p .r RECEPT AT 24" ^ �'• ``••' FOOD WARMER RECEPT. AT +12" _ IN CABINET BASE INTERCOM,SAFE PRINTER SYSTEM T-11; 1 IU ;ASH rs. AT +12" C2 NET BASE EGISTERS /POS RECEPT._ AT +28" FROZEN BEVERAGE DISPEN r 1 1 STUB —UP 1" CONDUIT +6" FUTURE ITEMS ON COFFEE FVBAR LILA FREESTANDING DELI CASE ECEPT. AT +12" IN CABINET BASE LOTTO TERMINAL EX. ICE i RE_CEPT. AT +12" i IN CABINET BASE CAS FliFI SYSTEM • j____ RECEPT._AT12" C5 IN CABINET BASE SAFE SYSTEM P 8' CIGARETTES 0T1' (below) 2' HBA AUTO ELECTRICAL ROUGH -IN PLAN C _ _RECEPT —a 1 " C18A ICE REAM NOVELTY CASE SCALE: 1/4"=1'- GENERAL NOTES A. ALL DIMENSIONS FOR UTILITIES LOCATED IN SLAB ARE RUNNING DIMENSIONS, TO BE FROM INSIDE FACE OF EXTERIOR WALL TO CENTER OF ROUGH —IN. ALL OTHER DIMENSIONS ARE FROM FACE OF STUD TO CENTER OF ROUGH -INS. B. ALL SERVICES SHOWN WITH SYMBOLS CENTERED ON FACE OF STUD WALL SHOULD BE BROUGHT TO THAT POINT CONCEALED IN WALL AND STUBBED OUT OF WALL CENTERED AT HEIGHT SHOWN. DO NOT STUB OUT OF FLOOR AND RUN EXPOSED UP FACE OF WALL UNLESS OTHERWISE NOTED. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 15 2009 City of Tukwila BUILDING DIVISION al a dr 3dr FREEZER REFRIGERATOR CI L = - - - - -= = - \-7-\ CON c1 O O HOOD CONTROL PANEL �2 5 TIER EXISTING OFFICE -r 511ER WATE ALt54' _ BOOSTER SAT 54'L COFFEE TIME TG10B 4" VEN AL±24" TGB HEESE DISP I r 1 I DI BEER SPLAY I L J T�rI —____ -11 - BUN EP AS. 4$" TG6 PRIMARY SODA 11_._ - -. s_Q z 0 u (Al :i z PRC MO 1 EXISTING SALES AREA BULK 0 z CJ s 0 PROMO III 2/MVE STUB UP (5) -1" & (1) -3/4" CONDUITS +6" FOR RECEPTS IN TRANSACTION COUNTER • • I r 1 3 2 4 EXISTING PREFAB OOLER 711 3 CANDY 3• JERKY DEPT. ET ASE C6A IN CABINET BASE ��� �. LOTTO TERMINAL ^,-'p .r RECEPT AT 24" ^ �'• ``••' FOOD WARMER RECEPT. AT +12" _ IN CABINET BASE INTERCOM,SAFE PRINTER SYSTEM T-11; 1 IU ;ASH rs. AT +12" C2 NET BASE EGISTERS /POS RECEPT._ AT +28" FROZEN BEVERAGE DISPEN r 1 1 STUB —UP 1" CONDUIT +6" FUTURE ITEMS ON COFFEE FVBAR LILA FREESTANDING DELI CASE ECEPT. AT +12" IN CABINET BASE LOTTO TERMINAL EX. ICE i RE_CEPT. AT +12" i IN CABINET BASE CAS FliFI SYSTEM • j____ RECEPT._AT12" C5 IN CABINET BASE SAFE SYSTEM P 8' CIGARETTES 0T1' (below) 2' HBA AUTO ELECTRICAL ROUGH -IN PLAN C _ _RECEPT —a 1 " C18A ICE REAM NOVELTY CASE SCALE: 1/4"=1'- GENERAL NOTES A. ALL DIMENSIONS FOR UTILITIES LOCATED IN SLAB ARE RUNNING DIMENSIONS, TO BE FROM INSIDE FACE OF EXTERIOR WALL TO CENTER OF ROUGH —IN. ALL OTHER DIMENSIONS ARE FROM FACE OF STUD TO CENTER OF ROUGH -INS. B. ALL SERVICES SHOWN WITH SYMBOLS CENTERED ON FACE OF STUD WALL SHOULD BE BROUGHT TO THAT POINT CONCEALED IN WALL AND STUBBED OUT OF WALL CENTERED AT HEIGHT SHOWN. DO NOT STUB OUT OF FLOOR AND RUN EXPOSED UP FACE OF WALL UNLESS OTHERWISE NOTED. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 15 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER REVISIONNO, _ 1. 161,01-055 Date Signed: Jun 30, 2009 SACRAMENTO ENO /NEER /NO CONSULTANTS 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com Job No. 09217 bp. , ..,„., A.. IFJ ARCO BP WEST COAST PRODUCTS, LLC G,HA(j S ..4,1,ii ?`_41.' o to y, CT/HQ ENG�AO' 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES EQUIPMENT ELECTRICAL LEGEND DATE 0 1 CONDUIT STUB —UP (SEE PLAN FOR SIZE) • ELECTRICAL ROUGH —IN LOCATION +12" HEIGHT OF ROUGH —IN ABOBE FINISHED FLOOR E.C. ELECTRICAL CONTRACTOR RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER REVISIONNO, _ 1. 161,01-055 Date Signed: Jun 30, 2009 SACRAMENTO ENO /NEER /NO CONSULTANTS 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com Job No. 09217 bp. , ..,„., A.. IFJ ARCO BP WEST COAST PRODUCTS, LLC G,HA(j S ..4,1,ii ?`_41.' o to y, CT/HQ ENG�AO' 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION LLB LLB A n� D 11 SEAL: CONFIDENTIALITY STATEMENT: THAT GLOBAL CONTAIN OF AGREES 10 AND TO ANY OTHER COPIES OF THE THE FOR WHICH AVAILABLE, TO OF THE OF GLOBAL THE RECIPIENT OF THESE MATERIALS UNDERSTANDS COPYRIGHT IN 7HE MATERIALS IS OWNED BY AWANCE, AND ALSO, THAT THE MATERIALS PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION GLOBAL AWANCE. ACCORDINGLY, THE RECIPIENT RETAIN THESE MATERIALS IN STRICT CONFIDENCE AGREES NOT TO DISCLOSE THEE MATERIALS PARTY AND FURTHER AGREES NOT TO MAKE MATERIALS. 1HE RECIPIENT AGREES TO USE MATERIALS ONLY FOR THE UNITED PURPOSE GLOBAL AWANCE HAS MADE THE MATERIALS AND RECIPIENT AGREES 10 RETURN ALL MATERIALS GLOBAL AWANCE EITHER UPON COMPLETION INTENDED PURPOSE OR UPON THE REQUEST AWANCE. WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ I-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CG AWANCE Z&DM: CHECKED BY: RH BP REPM: DRAWN BY AWANCE PM: VERSION: - PROJECT NO: 1975.75 DRAWING TITLE: ELECTRICAL ROUGH -IN PLAN SHEET NO: MDP PANEL 'X' t------ SERVICE GROUND SEE SINGLE LINE RISER DIAGRAM -. 0- POWER CONDITIONER 3 CONDITIONED POWER WIRING NOTES: OA PROVIDE 30 /1P C/B IN POWER PANEL FOR POWER CONDITIONER PANEL, CONNECT TO SAME PHASE AS DISPENSER POWER, KI THE GROUNDING CONDUCTOR TO THE POWER CONDITIONER SHALL BE CONNECTED TO A GROUND BUS IN THE MDP. © CIRCUITING FROM THE POWER CONDITIONER TO THE ISOLATED GROUND PANEL, SHALL BE IN METALLIC CONDUIT WITH SEPARATE NEUTRAL, PHASE WIRE, AND BONDING WIRE, PANEL 'X' LOOP ISOLATED #10 GROUND THRU PNL PANEL 'G' UNBROKEN TO PNL 'MDP' GROUND BUS ELECTRICALLY ISOLATED FROM PANEL ENCLOSURE METALLIC J. BOX — ISOLATED GROUND TREATMENT DIAGRAM SCALE: NO SCALE A -1,3- U LL C -2 E.C. TO PROVIDE AND INSTALL POWER CONDITIONER TO SERVICE ISOLATED GROUND PANEL, UNIT SHALL BE RATED AT 3000VA, (POWERVAR #ABC3030 -11) EO CIRCUITING FROM THE ISOLATED GROUND PANEL TO THE ISOLATED GROUND RECEPTACLES SHALL BE IN METALLIC RACEWAY (COMPLETELY SEPARATED FROM OTHER UNCONDITIONED POWER WIRING INCLUDING THE FEED TO THE POWER CONDITIONER — I.E. SEPARATE RACEWAYS, WIRE WAYS AND TROUGHS) WITH A SEPARATE NEUTRAL, PHASE WIRE, BOUNDING WIRE AND AN ISOLATED GROUND WIRE, THE BONDING WIRE SHALL BE SHARED WITH MULTIPLE ISOLATED GROUND CIRCUITS. • THE ISOLATED GROUND RECEPTACLES SHALL BEI DUPLEX — HUBBELL IG 5362 SIMPLEX — HUBBELL IG 5261 O ALL ISOLATED GROUND WIRING TO RECEPTACLES SHALL BE AWG #10 WITH A PIGTAIL SPLICE TO AWG #12 WITHIN JUNCTION BOX TO CONNECT #12 TO RECEPTACLE, OH ALL WIRING SHALL BE MINIMUM AWG #12 COPPER EXCEPT FOR ISOLATED GROUND WIRING WHICH SHALL BE AWG #10 COPPER MINIMUM. DI FOLLOW POWER CONDITIONER MANUFACTURER'S INSTRUCTION MANUAL FOR PROPER INSTALLATION, INSTALL ALL JUMPERS NECESSARY FOR 120 VOLT INPUT, O ALL RECEPTACLES SHALL BE LABELED ON THE FINISH PLATE WITH DYNAMO MARKER TAPE, LABEL SHALL INDICATE PANEL AND CIRCUIT NUMBER, EXISTING STORAGE CONTAINER EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE NEW UNISEX REST ROOM TYP. e\PNL' • GHq(j .° 0AVii i 0 ....Ilk 0 r ' ' ,'' A. `T /HG ENG11C 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DRAWING LEGEND REVISION DESCRIPTION SYMBOL DESCRIPTION IG ISOLATED GROUND FJ OH JUNCTION BOX +d SIMPLEX RECEPTACLE A\ DUPLEX RECEPTACLE 6 QUAD RECEPTACLE 208V 1? OR 208V 3? RECEPTACLE E- NON -FUSED DISCONNECT SWITCH DOUBLE GANG J -BOX WITH SINGLE GANG PLASTER RING TO BE PROVIDED BY AND INSTALLED BY ELECTRICAL CONTRACTOR PROVIDE SIEMON CT4 -FP -20 FACE PLATE W/ 2 SIEMON CT -AK -20 INSERTS. SEE RJ -45 RECEPTACLE WIRING DIAGRAM DETAIL FOR PROPER WIRING ORDER. ELECTRICIAN TO NUMBER EACH CONNECTION AS SHOWN TO COORDINATE WITH PATCH PANEL NUMBERS. WRITE -ON LABEL UNDER CLEAR PLASTIC COVER INDICATING PATCH PANEL IDENTIFIER PROVIDE PRINTED INSERTS FOR ALL LABELS (HANDWRITTEN NOT ACCEPTABLE). D DOUBLE GANG TELEPHONE OUTLET WIN SINGLE GANG PLASTER RING TO BE PROVIDED BY AND INSTALLED BY ELECTRICAL CONTRACTOR PROVIDE SIEMON CT4 -FP -20 FACE PLATE W/ 2 SIEMON CT -AK -20 INSERTS. SEE RJ -45 RECEPTACLE WIRING DIAGRAM DETAIL FOR PROPER WIRING ORDER ELECTRICIAN TO NUMBER EACH CONNECTION AS SHOWN TO COORDINATE WITH PATCH PANEL NUMBERS. WRITE -ON LABEL UNDER CLEAR PLASTIC COVER INDICATING PATCH PANEL IDENTIFIER PROVIDE PRINTED INSERTS FOR ALL LABELS (HANDWRITTEN NOT ACCEPTABLE). S SINGLE POLE TOGGLE SWITCH, 20 AMPERE RATED, MOUNTED 48" A.F.F. UNLESS NOTED OTHERWISE. SUBSCRIPT: "a" - LOWER CASE LETTER INDICATES SWITCH CONTROL. "P" - DENOTES LIGHTED HANDLE TOGGLE SWITCH, LAMP IN SWITCH SHALL LIGHT WHEN EQUIPMENT IS OPERATING. CONFIDENTIALITY STATEMENT: EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE NEW UNISEX REST ROOM TYP. e\PNL' Odr 3dr FREEZER REFRIGERATOR • BEER DISPLAY -5 \NOTE: ALL C ID1 S PAeSING \1'W UGH THE WA� OR FLOORS OF THE COOLER/FREEZER UNIT SEALED PER ARTICLE 300 -1 EXISTING OFFICE PRIMARY SODA Btn K 5, cE IL INGS 1 14L.L BE _1 (E) PANEL 'A' C -1 PROMO 1 EXISTING SALES AREA FRiTO H LLE[ �._ _...__,_.___ -j� A -20,22 A -3-1 C -1 USE .(E) CKT'S XISTING REFAB ;OGLER 3 CANDY 3' JERKY USE (E) CKT CASHI USE (E) CKT'S EX. !CE CREA 8' CIGARETTES 4 o OTP (babw) 2' NBA u u BCHE SWEET CAKES ELECTRICAL PLAN SCALE: 1/4'=1' -0" A E.1.2 ELECTRICAL NOTES I. EXISTING PANEL SCI- 4EDULE LABELING HAS NOT BEEN VERIFIED. PLANS ARE BASED ON THE ACCURACY OF THE EXISTING PANEL LABELING. CONTRACTOR SHOULD VERIFY ALL CIRCUITS. 2. VERIFY PEAK HISTORICAL LOADING WIN UTILITY COMPANY. 3. VERIFY NEW LOADS FALL WITHIN PANEL CAPACITY. 4. BALANCE ALL PANEL LOADS AT COMPLETION OF WORK 5. CONTRACTOR SHALL PROVIDE TYPEWRITTEN LABELS FOR COMPLETE ELECTRICAL PANELS FOLLOWING COMPLETION OF WORK PROVIDE BP WITH A COPY OF PANEL SCHEDULE FOR FUTURE MODIFICATION. 6. PROVIDE CEILING RECEPTACLES FOR BOTH SECURITY MONITORS. 1. UNDERGROUND CONDUIT MUST BE RIGID FOR FINAL 24" STUB -UPS .4T COUNTERS TO PROTECT FROM DAMAGE. 8. EXTEND EXISTING CONDUITS FROM SALES COUNTER CONTACT BP ENGINEER IF ADDITIONAL CONDUITS WILL NEED TO BE ADDED. 9. PROVIDE ISOLATED DEDICATED ELECTRICAL CIRCUIT AND PHONE LINE AT ATM REVISED LOCATION: FOI -LOWING ELECTRICAL MOVE COORDINATE WITH ATM VENDOR, FOR THE RELOCATION OF THE ATM. 10. MINIMIZE BENDS IN CONDUITS FOR NETWORK CABLING. 11. NOT USED. 12. COORDINATE THE RELOCATION OF THE SATELLITE-MODEM AT THE SALES COUNTER AND RECONNECTION-WITH-HUGHES SATELLITE. CABLE FOR SATELLITE CONNECTION MAY NOT BE CUT AND SPLICED. 1 13. CONTRACTOR TO ASSIST IN RECONNECTION OF INTERCOM AND ALL SALES COUNTER EQUIPMENT. 14. NOT USED. I. CONTRACTOR TO RELOCATE OVERHEAD ELEGTRIGA AND POLE FOR BREEZE COOLER (CI1A). 16. CONTRACTOR TO INSTALL ELECTRICAL FOR.NEW ICE. CREAM NOVELTY CASE AS NOTED ON THE PLAN 11. CONTRACTOR SHALL INSTALL NEW ELECTRICAL OUTLET AT SALES COUNTER FOR FOOD FORWARD PROGt M...L .. 18. CONTRACTOR TO INSTALL RECESSED SOFFI LIGHTING • OVER ALL MERCHANDISED AREAS. FOOD 'SERVICE AREAS MUST HAVE ADEQUATE SHATTER PROTECTION. 19. SALES REGISTERS/P05 SHALL BE UPGRADED TO ( ' 3 "RETAILIX" SYSTE WHEN AVAILIABLE. CONI'A�T' P.'^OR MORE INFORMATI N. REVIEWED FOR r CODE COMPLIANCE A' APPROVED JUL 15 2009 KEYED NOTES • ■ ▪ EXISTING AREA To REMAIN AS IS. E.C. TO ROUTE (2) 12 AND (1) 12 GROUND IN 1/2" CON AVAILABLE 120V, 20.4 BREAKER IN ELECTRICAL PANEL. City of Tukwila LDING DIVISION E.C. TO ROUTE (3) 12 AND (1) 12 GROUND IN 1/2" CONDUIT TO AVAILABLE 120V, 20A BREAKER IN ELECTRICAL PANEL. 1211X12" OPENING IN SLAB FOR ROUTING OF CONDUIT FOR CASHIER COUNTER REFER TO SHEET E.1,2 FOR CONDUIT SIZES. G.C. TO GROUT FINISHED FLOOR AFTER CIRCUIT INSTALLATION. E.C. TO ROUTE (4) 10 AND (1) "12 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, 3P 30A BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (3) "8 AND (1) 10 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, IF 40A BREAKER IN ELECTRICAL PANEL. n E.C. TO ROUTE (3) "8 AND (1) "10 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, 1P 50A BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (3) i4 AND (I) "8 GROUND IN I" CONDUIT TO AVAILABLE 208V, IF 10A BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (2) "12 AND (1) "12 GROUND WITH (1) 12 ISOLATED GROUND IN 1" fit. CONDUIT BACK TO 20A BREAKER IN POWER CONDITIONED PANEL. IF POWER CONQ NOT PRESENT E.C. TO PROVIDE AND INSTALL PER DETAIL 01 -E2.0. E.C. TO PROVIDE AND INSTALL CLASS "A" 5m4 GROUND FAULT BREAKER IN PANEL:- CONTROL PANEL FOR HOOD EXHAUST FAN. CONTROL PANEL FURNISHED AND INSTALLED BY CAPTIVE AIRE. LOCATION OF PROPOSED POWER CONDITIONER E.C. TO COORDINATE LOCATION PRIOR TO INSTALLATION. LONER 13 E.C. TO ROUTE (2) "12 AND (1) 12 GROUND IN LIQUID TIGHT TO FIELD BOX AT BOTTOM OF MILLWORK FROM FIELD BOX E.C. TO ROUTE TO AVAILABLE 120V, 204 BREAKER IN ELECTRICAL PANEL. IF NO SPARE BREAKER PRESENT E.C. TO PROVIDE AND INSTALL BREAKER E.C. TO ROUTE (3) "12 AND (1) "12 GROUND IN LIQUID TIGHT TO FIELD BOX AT BOTTOM OF MILLWORK FROM FIELD BOX E.G. TO ROUTE TO AVAILABLE 120V, 20A BREAKER IN ELECTRICAL PANEL. IF NO SPARE BREAKER PRESENT E.C. TO PROVIDE AND INSTALL BREAKER . CONTRACTOR TO INSTALL NEW EMERGENCY SHUTDOWN SWITCH (E.S.O.) AT SALES COUNTER (INCLUDING RESET) AND ALSO REPLACE EXISTING ONE AT BUILDING EXTERIOR CONTRACTOR TO VERIFY THAT EMERGENCY SHUTDOWN SWITCHES ARE WIRED TO SHUT DOWN BOTH TURBINES AND DISPENSERS. REWIRE TO DISPENSER MANAGER IF NOT EXISTING. ESC) SWITCH SHALL BE DISTINCLY LABELED AS "EMERGENCY FUEL SHUTDOWN DEVICE." SIGNS SHALL BE PROVIDED IN APPROVED LOCATIONS AS DETERMINED BY THE FIRE INSPECTOR. RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER 1 EXPIRES 10 -24 -201 Date Signed: Jun 30, 2009 SACRAMENTO ENO /NEER /NO CONSULTANTS 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com Job No. 09217 bp • Odr 3dr FREEZER REFRIGERATOR • BEER DISPLAY -5 \NOTE: ALL C ID1 S PAeSING \1'W UGH THE WA� OR FLOORS OF THE COOLER/FREEZER UNIT SEALED PER ARTICLE 300 -1 EXISTING OFFICE PRIMARY SODA Btn K 5, cE IL INGS 1 14L.L BE _1 (E) PANEL 'A' C -1 PROMO 1 EXISTING SALES AREA FRiTO H LLE[ �._ _...__,_.___ -j� A -20,22 A -3-1 C -1 USE .(E) CKT'S XISTING REFAB ;OGLER 3 CANDY 3' JERKY USE (E) CKT CASHI USE (E) CKT'S EX. !CE CREA 8' CIGARETTES 4 o OTP (babw) 2' NBA u u BCHE SWEET CAKES ELECTRICAL PLAN SCALE: 1/4'=1' -0" A E.1.2 ELECTRICAL NOTES I. EXISTING PANEL SCI- 4EDULE LABELING HAS NOT BEEN VERIFIED. PLANS ARE BASED ON THE ACCURACY OF THE EXISTING PANEL LABELING. CONTRACTOR SHOULD VERIFY ALL CIRCUITS. 2. VERIFY PEAK HISTORICAL LOADING WIN UTILITY COMPANY. 3. VERIFY NEW LOADS FALL WITHIN PANEL CAPACITY. 4. BALANCE ALL PANEL LOADS AT COMPLETION OF WORK 5. CONTRACTOR SHALL PROVIDE TYPEWRITTEN LABELS FOR COMPLETE ELECTRICAL PANELS FOLLOWING COMPLETION OF WORK PROVIDE BP WITH A COPY OF PANEL SCHEDULE FOR FUTURE MODIFICATION. 6. PROVIDE CEILING RECEPTACLES FOR BOTH SECURITY MONITORS. 1. UNDERGROUND CONDUIT MUST BE RIGID FOR FINAL 24" STUB -UPS .4T COUNTERS TO PROTECT FROM DAMAGE. 8. EXTEND EXISTING CONDUITS FROM SALES COUNTER CONTACT BP ENGINEER IF ADDITIONAL CONDUITS WILL NEED TO BE ADDED. 9. PROVIDE ISOLATED DEDICATED ELECTRICAL CIRCUIT AND PHONE LINE AT ATM REVISED LOCATION: FOI -LOWING ELECTRICAL MOVE COORDINATE WITH ATM VENDOR, FOR THE RELOCATION OF THE ATM. 10. MINIMIZE BENDS IN CONDUITS FOR NETWORK CABLING. 11. NOT USED. 12. COORDINATE THE RELOCATION OF THE SATELLITE-MODEM AT THE SALES COUNTER AND RECONNECTION-WITH-HUGHES SATELLITE. CABLE FOR SATELLITE CONNECTION MAY NOT BE CUT AND SPLICED. 1 13. CONTRACTOR TO ASSIST IN RECONNECTION OF INTERCOM AND ALL SALES COUNTER EQUIPMENT. 14. NOT USED. I. CONTRACTOR TO RELOCATE OVERHEAD ELEGTRIGA AND POLE FOR BREEZE COOLER (CI1A). 16. CONTRACTOR TO INSTALL ELECTRICAL FOR.NEW ICE. CREAM NOVELTY CASE AS NOTED ON THE PLAN 11. CONTRACTOR SHALL INSTALL NEW ELECTRICAL OUTLET AT SALES COUNTER FOR FOOD FORWARD PROGt M...L .. 18. CONTRACTOR TO INSTALL RECESSED SOFFI LIGHTING • OVER ALL MERCHANDISED AREAS. FOOD 'SERVICE AREAS MUST HAVE ADEQUATE SHATTER PROTECTION. 19. SALES REGISTERS/P05 SHALL BE UPGRADED TO ( ' 3 "RETAILIX" SYSTE WHEN AVAILIABLE. CONI'A�T' P.'^OR MORE INFORMATI N. REVIEWED FOR r CODE COMPLIANCE A' APPROVED JUL 15 2009 KEYED NOTES • ■ ▪ EXISTING AREA To REMAIN AS IS. E.C. TO ROUTE (2) 12 AND (1) 12 GROUND IN 1/2" CON AVAILABLE 120V, 20.4 BREAKER IN ELECTRICAL PANEL. City of Tukwila LDING DIVISION E.C. TO ROUTE (3) 12 AND (1) 12 GROUND IN 1/2" CONDUIT TO AVAILABLE 120V, 20A BREAKER IN ELECTRICAL PANEL. 1211X12" OPENING IN SLAB FOR ROUTING OF CONDUIT FOR CASHIER COUNTER REFER TO SHEET E.1,2 FOR CONDUIT SIZES. G.C. TO GROUT FINISHED FLOOR AFTER CIRCUIT INSTALLATION. E.C. TO ROUTE (4) 10 AND (1) "12 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, 3P 30A BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (3) "8 AND (1) 10 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, IF 40A BREAKER IN ELECTRICAL PANEL. n E.C. TO ROUTE (3) "8 AND (1) "10 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, 1P 50A BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (3) i4 AND (I) "8 GROUND IN I" CONDUIT TO AVAILABLE 208V, IF 10A BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (2) "12 AND (1) "12 GROUND WITH (1) 12 ISOLATED GROUND IN 1" fit. CONDUIT BACK TO 20A BREAKER IN POWER CONDITIONED PANEL. IF POWER CONQ NOT PRESENT E.C. TO PROVIDE AND INSTALL PER DETAIL 01 -E2.0. E.C. TO PROVIDE AND INSTALL CLASS "A" 5m4 GROUND FAULT BREAKER IN PANEL:- CONTROL PANEL FOR HOOD EXHAUST FAN. CONTROL PANEL FURNISHED AND INSTALLED BY CAPTIVE AIRE. LOCATION OF PROPOSED POWER CONDITIONER E.C. TO COORDINATE LOCATION PRIOR TO INSTALLATION. LONER 13 E.C. TO ROUTE (2) "12 AND (1) 12 GROUND IN LIQUID TIGHT TO FIELD BOX AT BOTTOM OF MILLWORK FROM FIELD BOX E.C. TO ROUTE TO AVAILABLE 120V, 204 BREAKER IN ELECTRICAL PANEL. IF NO SPARE BREAKER PRESENT E.C. TO PROVIDE AND INSTALL BREAKER E.C. TO ROUTE (3) "12 AND (1) "12 GROUND IN LIQUID TIGHT TO FIELD BOX AT BOTTOM OF MILLWORK FROM FIELD BOX E.G. TO ROUTE TO AVAILABLE 120V, 20A BREAKER IN ELECTRICAL PANEL. IF NO SPARE BREAKER PRESENT E.C. TO PROVIDE AND INSTALL BREAKER . CONTRACTOR TO INSTALL NEW EMERGENCY SHUTDOWN SWITCH (E.S.O.) AT SALES COUNTER (INCLUDING RESET) AND ALSO REPLACE EXISTING ONE AT BUILDING EXTERIOR CONTRACTOR TO VERIFY THAT EMERGENCY SHUTDOWN SWITCHES ARE WIRED TO SHUT DOWN BOTH TURBINES AND DISPENSERS. REWIRE TO DISPENSER MANAGER IF NOT EXISTING. ESC) SWITCH SHALL BE DISTINCLY LABELED AS "EMERGENCY FUEL SHUTDOWN DEVICE." SIGNS SHALL BE PROVIDED IN APPROVED LOCATIONS AS DETERMINED BY THE FIRE INSPECTOR. RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER 1 EXPIRES 10 -24 -201 Date Signed: Jun 30, 2009 SACRAMENTO ENO /NEER /NO CONSULTANTS 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com Job No. 09217 bp A‘t. IF ARCO BP WEST COAST PRODUCTS, LLC GHq(j .° 0AVii i 0 ....Ilk 0 r ' ' ,'' A. `T /HG ENG11C 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION 0 IL +d A\ /e\ 0 2 0 A A SEAL: SD 355 CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL AWANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS P4 STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES 10 USE THE MATERIALS ONLY FOR THE UNITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CG AWANCE Z&DM: CHECKED BY: RH BP REP.: DRAWN BY: _ AW AWANCE PM: VERSION: _ - PROJECT NO: 1975.75 DRAWING TITLE: ELECTRICAL • FLOOR PLAN SHEET NO: E.1.2 EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE EXISTING STORAGE CONTAINER X gamonwom Mv1SO EXISTING OFFICE EXISTING 1 RESTRObt) Tr ~� 11 \ 1 11 \\ 1 \ ) �a1 I�—%1 [Z_� I I \_/ BACKROOM TANK P>�.I1IEL "A" MONITOR _1 lI I V 4 (R) di) 1 1 1 ll L —_J .ANWA,O'.AIV K'>LSVVIAV VLV4,47414..".IVV VVIA MIA,9'•.V.• 4/ / '' x x x II I I I II -(I L- _ J GENERAL NOTE: DISCONNECT AND REMOVE EXISTING OUTLETS FEEDING EQUIPMEKfBEIN1REMOVEDI. VERIFY1 RE -USE OF OUTLET WI NIE.!U EQUIF'ME TYPICAL I I I /\ 1 I I I II / \ /\ >= / /'/ XISTING // / L____BALES / AREA / / \ / ✓. / NOTE: REFER TO SHEET Q.1.1 FOR EQUIPMENT SCHEDULE AND DESCRIPTION. ELECTRICAL DEMOLITION PLAN ESO flhl ITTTl 11111 flhl 1111111111111111111 I L1111111J I1ll1 I (R) I i(R) I 1 CASHIER Jf j.. ^114 W -- XISTING REFAB OOLER SCALE: 1/4 ":1' -0" .1,111111111.1•111Z1111111011401010 1•111.1111V1 u ., T EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE EXISTING STORAGE CONTAINER EXIS1 NG OM ,E rF IEX IRE 11 Jh k' it 1�I _ 1—BACKR001. PRESCOL ITE AKTMLCE218 1RK 1.11.5.1_11)434F-11 .I, Tt 11 / II r = - -r'_'--' _'°li ►—', -r t ° 1.... _ -elf �... _ ..._'. '" 1 fl 11. I I LJ _Gw �x) I 1 1 4 lin 1 Iwo am (E) FIXTURE TO REMAIN, TYPICAL DEMOLITION LIGHTING PLAN x XISTING REFAB OOLER SCALE: 1/8" :1' -0" EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE CONTAINER (E) FIXTURE TO BE REMOVED, TYPICAL (E) FIXTURE TO BE RELOCATED, TYPICAL EXIST NG OFFI 2E EX: RE m r MC L ROAM fl 'A' TNM !oral 1 I II AA IHNH:IIIIIIl,II :IIIIIII IIIIIII:111111� 11 :1111111 m m ( —) C2, TYPICAL (u) EXISTING iREFAB :OGLER u IIIIIII ::IIIIII.,IIIIIII :IIIIIII_ NUMBERED NOTES C4, TYPICAL CONNECT NEW LIGHTS TO EXISTING LIGHTING CIRCUIT. EXTEND EXISTING LIGHTING CIRCUIT TO NEW LIGHTS. INSTALL NEW SWITCHES TO CONTROL NEW LIGHTS. NEW LIGHTING PLAN SCALE: 1/8 ":1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED I JUL 15 2009 City of Tukwila BUILDING DIVISION ELO Q355 Date Signed: Jun 30, 2009 RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER A■ 1rx LIGHT FIXTURE SCHEDULE SACRAMENTO, =ENO /NEER /NO CONSULTANTS G,HAO SYMBOL MARK TYPE MOUNTING QTY MANUFACTURE AND CATALOG NUMBER LAMPING OW VOLTS warns TYPE DATE REVISION DESCRIPTION A A FLUORESCENT SURFACE 1 2x4 SURFACE PARABOLIC CUBE LIGHT FIXTURE MATCH EXISTING LSI FIXTURE 2 120 32 LAMPS— SYLVANIA #F 032 /835 /XPS /ECIJ BALLAST — SEE NOTE B C2 FLUORESCENT SURFACE 1 LOW PROFILE WRAPAROUND LSI #WNA10 2 SS12 F UE 2 120 32 LAMPS- SYLVANIA #FO32 /835 /XPS /ECJ BALLAST - SEE NOTE B I- ° C2 FLUORESCENT LAY -IN 4 1x2 LAY -IN, WALL WASH WITH SIDE MOUNTED LAMPS LSI #NWW217- SSO1ORPSX- LMP841- UE -OSR -SYL 2 120 17 F17 T8 !111111 /12\ C4 FLUORESCENT LAY —IN 10 1x4 LAY —IN, WALL WASH WITH SIDE MOUNTED LAMPS LSI #NWW232— SSO1ORPSX— LM841— UE —OSR —SYL 2 120 32 LAMPS— SYLVANIA #F032 /835 /XPS /ECO BALLAST — SEE NOTE B ImIN:II11�11, 0 W WALL WASH RECESSED 7 6' VERTICAL REFLECTOR DOWNLIGHT WITH A SEMI CLEAR SPECULAR FINISH LSI #206V— CFL- 1- 26T— UE- 206VCL— LM2627 1 120 23 GE COMPACT FLUORESCENT GE GENURA EL23 /R25 /SW 0 W1 DOWNLIGHT RECESSED 4 SELF FLANGED, SINGLE REFLECTOR WITH A SPECULAR CLEAR FINISH LSI #206HCFL- 1 -26Q- UNIV- C27- 206HL- LMP2627 1 120 26 AWANCE Z&DM: CHECKED BY: RH 0 VAPOR /DOWNLIGHT SURFACE _ VAPOR PROOF LIGHT FOR FREEZER/ COOLER LSI #VP12- 1 -42T— CFL— UE— LM4227 1 120 42 ELECTRICAL DEMO /LIGHTING 1-7 EM1 BATTERY BACK UP CEILING/ WALL — COMBO LED EXIT SIGN AND EMERGENCY LIGHT LSI #EMEX- 1 —R —W- 120/277 2 6V 5.4 NOTES: DENOTES THAT FLUORESCENT FIXTURE IS TO BE PROVIDED WITH A SELF B. BALLAST SHALL BE QTP2X32T8 /UNV PSX TC W/ UNIVERSAL VOLTAGE AND PROGRAM START, EM CONTAINED EMERGENCY BACKUP BATTERY TO POWER ONE LAMP FOR 90 MINUTES C. BALLAST SHALL BE QTP3X32T8 /UNV PSX TC W/ UNIVERSAL VOLTAGE AND PROGRAM START, UPON LOSS OF AC POWER, LSI #EM132 D. ALL 32W T8 LAMPS TO HAVE CRI OF 3500K, EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE EXISTING STORAGE CONTAINER X gamonwom Mv1SO EXISTING OFFICE EXISTING 1 RESTRObt) Tr ~� 11 \ 1 11 \\ 1 \ ) �a1 I�—%1 [Z_� I I \_/ BACKROOM TANK P>�.I1IEL "A" MONITOR _1 lI I V 4 (R) di) 1 1 1 ll L —_J .ANWA,O'.AIV K'>LSVVIAV VLV4,47414..".IVV VVIA MIA,9'•.V.• 4/ / '' x x x II I I I II -(I L- _ J GENERAL NOTE: DISCONNECT AND REMOVE EXISTING OUTLETS FEEDING EQUIPMEKfBEIN1REMOVEDI. VERIFY1 RE -USE OF OUTLET WI NIE.!U EQUIF'ME TYPICAL I I I /\ 1 I I I II / \ /\ >= / /'/ XISTING // / L____BALES / AREA / / \ / ✓. / NOTE: REFER TO SHEET Q.1.1 FOR EQUIPMENT SCHEDULE AND DESCRIPTION. ELECTRICAL DEMOLITION PLAN ESO flhl ITTTl 11111 flhl 1111111111111111111 I L1111111J I1ll1 I (R) I i(R) I 1 CASHIER Jf j.. ^114 W -- XISTING REFAB OOLER SCALE: 1/4 ":1' -0" .1,111111111.1•111Z1111111011401010 1•111.1111V1 u ., T EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE EXISTING STORAGE CONTAINER EXIS1 NG OM ,E rF IEX IRE 11 Jh k' it 1�I _ 1—BACKR001. PRESCOL ITE AKTMLCE218 1RK 1.11.5.1_11)434F-11 .I, Tt 11 / II r = - -r'_'--' _'°li ►—', -r t ° 1.... _ -elf �... _ ..._'. '" 1 fl 11. I I LJ _Gw �x) I 1 1 4 lin 1 Iwo am (E) FIXTURE TO REMAIN, TYPICAL DEMOLITION LIGHTING PLAN x XISTING REFAB OOLER SCALE: 1/8" :1' -0" EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE CONTAINER (E) FIXTURE TO BE REMOVED, TYPICAL (E) FIXTURE TO BE RELOCATED, TYPICAL EXIST NG OFFI 2E EX: RE m r MC L ROAM fl 'A' TNM !oral 1 I II AA IHNH:IIIIIIl,II :IIIIIII IIIIIII:111111� 11 :1111111 m m ( —) C2, TYPICAL (u) EXISTING iREFAB :OGLER u IIIIIII ::IIIIII.,IIIIIII :IIIIIII_ NUMBERED NOTES C4, TYPICAL CONNECT NEW LIGHTS TO EXISTING LIGHTING CIRCUIT. EXTEND EXISTING LIGHTING CIRCUIT TO NEW LIGHTS. INSTALL NEW SWITCHES TO CONTROL NEW LIGHTS. NEW LIGHTING PLAN SCALE: 1/8 ":1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED I JUL 15 2009 City of Tukwila BUILDING DIVISION ELO Q355 Date Signed: Jun 30, 2009 RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER cum bp � i A■ 1rx ARCO SACRAMENTO, =ENO /NEER /NO CONSULTANTS G,HAO 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com Job No. 09217 cum bp � i A■ 1rx ARCO BP WEST COAST PRODUCTS, LLC G,HAO � `p� V . 0- .,11L._ \:9::; Q ENG \ 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION A A A A 0 A A ^0 It /12\ SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN 7HE MATERIALS IS OWNED BY GLOBAL AWANCE: AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE UNITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CG AWANCE Z&DM: CHECKED BY: RH BP REM: DRAWN BY: _ AWANCE PM: VERSION: - PROJECT N0: _ 1975.75 DRAWING TITLE: ELECTRICAL DEMO /LIGHTING FLOOR PLAN SHEET NO: E. E.1.3 Effective: DMZ Alternate Telecoms Solution 120/40V. NEW PANEL C 100 AMP BUS 1 Ph. 3W. SURFACE ISC MOUNTED DESCRIPTION KVA BKR CKT Ph. A Ph. B CKT BKR KVA DESCRIPTION DESCRIPTION FOOD WARMER WATER BOOSTER 0.6 20/1 1 1.4 5.8 2 20/1 0.8 OFFICE COMPUTER REACH -IN FREEZER CHILI /CHEESE DISP 0.8 0.8 1.2 20/2 20/1 3 1.6 4 20/1 0.8 REACH -IN IEF'R 5 7 2.2 6 20/1 1.4 CONDIMENT REF'R 1.2 8 (E) MENU BD 0 4 20/1 10 0.8 0.6 10 20/1 0.4 (E) FANS 9 � 20/1 60/2 11 13 4.9 11 13 12 12 0.6 (E) FRZR LTG / (E) FAN (E) WINE COOLER 11 13 14 14 0.6 15 0.8 0.8 4.9 16 20/1 15 17 (E) MILK COOLER 16 0 4 0 4 20/1 20/1 17 19 0.4 20/1 18 (E) POP SIGN SPARE 1.0 20 15/2 19 (E) ICE MA ER SPARE SPACE 20 20/1 21 23 0.6 SUBTOTAL: 3.6 2.8 24 CONNECTED LOAD 6.4 KVA 1.0 1.0 DELI COOL R MAIN LUGS ONLY 25% LIGHTING LOAD KVA 25% LARGEST MOTOR KVA 20/1 20/1 20/20 25 27 29 1.2 1.4 1st 10.0 KVA RECEPTACLE LOAD @ 100% 26 PLUS REMAINDER @ 50% KVA TOTAL LOAD 6.4 KVA / 0.249 FACTC 27 AMPS APG Cash Drawer Epson Printer Symbol Scanner Site PC SurePOS. 500 Verrone OMNI700 pinpad POS 1 �. Distributed display APG Cash .Drawer Epson Printer Lexm ark BOS printer Verirone V900 (EPS) Symbol Scanner SATELLITE DISH ON ROOF PIC unit Forecourt devices SurePOS:. 500 Verrone OMNI700 pinpad Distributed display' POS •2. GENERAL NOTES 3 2 3 1 1 1 1 1 2 1 1 (E) PANEL B 120/240V. 1 Ph. 3W. 400 AMP BUS SURFACE MOUNTED ISC DESCRIPTION KVA BKR CKT Ph. A Ph. B CKT BKR KVA DESCRIPTION FOOD WARMER KVA CONVECTION OVEN 4 1 4 1 40/2 1 3 5.8 1 2 20/2 1.7 1.7 5.8 4 OVEN HOOD BUN TOASTER 1 8 1 8 20/1 20/1 5 7 2.4 6 20/1 0.6 (E) FREEZER 2.0 8 20/1 0.2 (E) OFFICE COMP (E) MENU BD 0 4 20/1 9 0.8 0.6 10 20/1 0.4 (E) FANS (E) BCK BLG LTG (E) FUEL SUB MAIN 0 6 4 3 4 3 20/1 60/2 11 13 4.9 1.2 12 20/15 0.6 (E) FRZR LTG / (E) FAN (E) WINE COOLER 11 13 14 20/1 0.6 15 0.8 0.8 4.9 16 20/1 0.6 (E) MILK COOLER (E) COUNTER REC (E) COUNTER REC 0 4 0 4 20/1 20/1 17 19 0.4 20/1 18 (E) POP SIGN SPARE 1.0 20 15/2 0.6 0.6 (E) ICE MA ER SPARE SPACE 19 21 23 20/1 21 23 0.6 22 1.0 24 20/2 1.0 1.0 DELI COOL R (E) SITE CONTROL MICROWAVE (E) AIR WATER / (E) ATM 0 2 1 7 0 4 20/1 20/1 20/20 25 27 29 1.2 1.4 20/20 26 2.7 28 30 20/2 1.0 1.0 (E) FREEZER 29 (E) HOT WTR TANK 1 0 1 0 30/2 31 33 2.0 2.0 32 20/2 1.0 1.0 (E) FREEZER 34 (E) HEAT PUMP (E) HEAT PUMP 3 0 30 3 0 3 0 50/2 50/2 35 (E) COUNTER ,REC 7.0 36 60/2 4.0 4.0 (E) FURNACE 37 39 7.0 20/1 20/1 38 7.0 40 60/2 4.0 4.0 (E) FURNAC 41 7.0 20/2 42 SUBTOTAL: 33.5 34.6 20/20 CONNECTED LOAD 68.1 KVA 1.4 MAIN LUGS ONLY 25% LIGHTING LOAD KVA 25% LARGEST MOTOR KVA 22.9 22.4 1st 10.0 KVA RECEPTACLE LOAD @ 100% PLUS REMAINDER @ 50% KVA CONNECTED LOAD 4'.3 KVA TOTAL LOAD 68.1 KVA / 0.240 FACTC 284 AMPS 25% LIGHTING LOAD KVA 25% LARGEST MOTOR KVA 1. ALL WIRING MUST CONFORM TO NEC AND LOCAL ELECTRIC CODES. 2. ALL CONDUIT AND ELECTRICAL FITTINGS MUST BE RATED FOR GROUND USE. 3. POWER CONDI11ONER SHALL BE INSTALLED ACCORDING TO MANUFACTURER INSTRUCTIONS. 4. 10 GROUND BUSS SHALL BE INSULATED FROM THE PANEL VIA A NON - CONDUC11VE MOUNTING: SQUARE D PKGTAR OR EQUIVALENT. 5. THE POWER CONDI11ONER OUTPUT AND ALL ISOLATE, CONDITIONED CIRCUITS ARE TO BE RUN IN SEPARATE CONDUITS FROM ALL NON - CONDITIONED CIRCUITS. MULTIPLE CONDITIONED CIRCUITS MAY SHARE THE SAME CONDUIT. 6. ALL GROUND CONDUCTORS IN SUB PANELS MUST TERMINATE TO PROPER GROUNDING CONNECTIONS. DO NOT TERMINATE CROUNDING CONDUCTORS TO THE NEUTRAL BUSS IN A SUB- PANEL. NDTES+ 1, FC NEEDS FIXED IP ADDRESS 192.168.10.10 2. DSU LOCATION? THIS ASSUMES IT IS UNDER THE FRONT COUNTER AS TODAY 3, FC ASSIGNS DM IP ADDRESSES WIRE LEGEND' CAT5 UTP CAT5 UTP PATCH CORD LEGACY SERIAL CONNECTIONS PIC UNIT ABOX TLS PIC UNIT ALLIED BOX TANK LEVEL SENSOR PP EPS ■ 0 0 PIN PAD ELECTRONIC PAYMENT SYSTEM 2 CAT 5 1 CAT 5 CAT 5 LAN CABLE TO DM 1 PER DISPENSER Hag oa 0 000 ATM ATM AREA POS DIAGRAM SCALE: N.T.S. 2 1 1 1 1 1 1 1 2 1 1 1 1 3 1 1 1 3 1 1 1 1 3 2 3 1 (E) PANEL A 200 120/240V. 1 Ph. 3W. AMP BUS ISC SURFACE MOUNTED DESCRIPTION KVA BKR CKT Ph. A Ph. B CKT 0 BKR KVA DESCRIPTION FCB DISPENSER 2. 2.' 40/2 1 2.6 ? 20/2 0.4 0.4 (E) ICE CUBER 3 2.6 (E) PUMP LIGHTS 0. 0.: 20/2 5 7 1.4 • 20/20 0.6 (E) CANOPY LIGHTS SEAL: 1.4 • 20/1 0.6 (E) CANOPY CVTLR SPACE / SPACE DESIGNED BY: CG 20/20 9 0.6 DRAWN BY: 1 • 20/20 0.6 (E) CNPY LT / (E) OFF SPACE / (E) STORE LT (E) STORE LT / SPACE 1.1 0. • 20/20 20/20 11 13 1.4 1.8 1' 20/2 0.8 0.8 (E) ID SIGN 1 . COFFEE BREWER 3.0 3.1 40/2 15 17 3.8 3.4 1 • 20/1 0.4 (E) POP SIGN 1: 20/20 0.8 (E) POP / (E) VIDEO COFFEE BREWER (E) ICE CRM F II EEZER (E) ILLUMINATED FASCIA (E) ILLUMINATED FASCIA (E) CLR COMPRESS (E) SUB MAIN 0.: 0.: 2. " 2.11 3.• 3 . 20/1 20/1 30/2 100/2 19 21 23 3.8 3.8 2. 40/2 20/20 3.0 3.0 0.6 22 24 2.6 25 27 2.6 23 28 20/20 0.6 (E) ICE CRM FRREEZER 3.5 SPACE 29 3.5 30 SPACE SPACE COFFEE COUNTER 0. 20/1 31 33 0.8 0.4 32 20/20 0.4 (E) COUNTER ,REC 34 20/1 0.4 (E) COUNTER RI EC (E) COUNTER REC ICED LATTE LATTE STEAMER 1. 1. 20/1 20/1 35 37 2.4 1.5 36 20/1 0.4 38 20/2 0.6 0.6 (E) HOZHIZAKI ICE (E) CLR LTS / (E) HTR 0.: 20/20 39 1.4 40 SUBTOTAL: 22.9 22.4 CONNECTED LOAD 4'.3 KVA MAIN LUGS ONLY 25% LIGHTING LOAD KVA 25% LARGEST MOTOR KVA 1st 10.0 KVA RECEPTACLE LOA' @ 100% PLUS REMAINDER @ 50% KVA TOTAL LOAD 4-.3 KVA / 0.240 FACTC 189 AMPS 1 1 1 1 1 1 3 1 1 1 1 1 1 1 PANEL NOTES: 1. EXISTING BREAKER AND LOAD. 2. EXISTING BREAKER. CONNECT NEW LOAD. 3. INSTALL NEW BREAKER WITH ALL NECESSARY MOUNTING HARDWARE AND CONNECT NEW LOAD. (E) MAIN SWITCHBOARD - "MSB" U.G. PULL (E) METER/MA IN --1) DISTRIBUTION SECTION SECTION SECTION Ilia AI (E) 600 AMP, 120/240 VOLT, 1 PHASE, 3 WIRE BUS. VERIFY AIC ) 600/2 • NEUT GND SINGLE LINE DIAGRAM ? (E) �(E) o) 200/2 0� 400/2 (E) PANEL (E) PANEL 'B' (E) PANEL TkNEUJ If00/2 1- 1 /4 "C. 3#3 CU. NEW PANEL 'C' REVIEWED FOR }a CODE COMPLIANCE'''. JUL 15 2009 SCALE: NONE POS "B" POS "A" p 1 I II BUILDING DIVI� I SIOI KEYED NOTES: 0 0 0 0 0 0 1 -1/4' CONDUIT FROM MANAGERS CPU FOR DATA CABL 1 -1/4' CONDUIT FROM DISPENSER INTERFACE. 1 -1/4' CONDUIT FROM ELECTRIC PANELS. (CLEAN POWER) 3/4' CONDUIT UNDER SLAB TO MANAGERS OFFICE FLIR "SECURITY, 1 -1/4' CONDUIT UNDER SLAB FOR GENERAL POWER, 1 -1/4' CONDUIT UNDER SLAB TO INTERCOM TROUGH, 111!111111111 0 BPS00-SHF16 BPS00SHF16 CONVEN. RECEPTACLE ,,, ,,, e 0 0 OPEN SAFE 0 00 0 00 ISOLATED GROUND FOR SAFE SALES COUNTER ELEVATION SCALE: NONE CONVEN -J RECEPTACLE ISOLATED GROUND - (1) DATA JACK (2) SIMPLEX OUTLETS LOTTERY MACHIN DATA JACK FOR LOTTERY MACHINE '-CONVEN. RECEPTACLEISOLATED GROUND -1 FOR SAFE TELEPHONE AND FAX MAXHINE ELO 9- 0356 EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 RECE CITY OF TUKWILA JUL 0 8 2UO PERMIT CENTER C SACRAMENTO ENO /NEER /NO CONSULTANTS, 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com Job No. 09217 ctsn>R bp r ..,„ IF�t� .4. ARCO BP WEST COAST PRODUCTS, LLC RP‘Vi A Qt., ....°i/i3O,11," 0 -Ilk- o /r 6 -, v. �, T�NO E N G,NO' 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES ,� T„.,,, CONVEN. RECEPTACLE ,,, ,,, e 0 0 OPEN SAFE 0 00 0 00 ISOLATED GROUND FOR SAFE SALES COUNTER ELEVATION SCALE: NONE CONVEN -J RECEPTACLE ISOLATED GROUND - (1) DATA JACK (2) SIMPLEX OUTLETS LOTTERY MACHIN DATA JACK FOR LOTTERY MACHINE '-CONVEN. RECEPTACLEISOLATED GROUND -1 FOR SAFE TELEPHONE AND FAX MAXHINE ELO 9- 0356 EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 RECE CITY OF TUKWILA JUL 0 8 2UO PERMIT CENTER C SACRAMENTO ENO /NEER /NO CONSULTANTS, 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com Job No. 09217 ctsn>R bp r ..,„ IF�t� .4. ARCO BP WEST COAST PRODUCTS, LLC RP‘Vi A Qt., ....°i/i3O,11," 0 -Ilk- o /r 6 -, v. �, T�NO E N G,NO' 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION /2\ 0 0 O 1, SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT N THE MATERIALS IS OWNED BY GLOBAL AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE UNITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALUANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE. WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ I-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CG AWANCE Z&DM: CHECKED BY: RH BP REPM: DRAWN BY: AWANCE PM: VERSION: - - PROJECT NO: 1975.75 DRAWING TITLE: ELECTRICAL SCHEDULES & DIAGRAMS SHEET NO: E.1.4 4