Loading...
HomeMy WebLinkAboutPermit EL09-0485 - WESTFIELD SOUTHCENTER MALL - CAFE PHOCAFE PHO 2600 SOUTHCENTER MALL F&8 ELO9-0485 CitAf Tukwila � Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL09 -0485 Issue Date: 09/14/2009 Permit Expires On: 03/13/2010 Tenant: Name: CAFE PHO Address: 2600 SOUTHCENTER MALL, FC -8 , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC BSIP Phone: Address: TOTAL 13 PARCEL NUMBERS , 2010 NEW PLAT MAJOR 920247 Contact Person: Name: TSE ARCHITECTS, DAVID WU Phone: 425 481 -6601 Address: 12930 NE 178 ST , WOODINVILLE WA Contractor: Name: HANKOOK INC Address: 34300 13TH PL SW , FEDERAL WAY WA Contractor License No: HANKOI *945LW Phone: 253 661 -8476 Expiration Date: 06/16/2010 DESCRIPTION OF WORK: ELECTRICAL FOR NEW TENANT IN FOOD COURT Value of Electrical: NRES: $20,000.00 RES: $0.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $520.00 National Electrical Code Edition: 2005 Date: 0111I l l Y o' I hereby certify that I have read and - ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: / Date: / /1--r Print Name: /1/1.-"\.7. �r- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0485 Printed: 09 -14 -2009 Parcel No.: 6364200010 Address: Suite No: Tenant: CAFE PHO • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW Permit Number: Status: Applied Date: Issue Date: EL09 -0485 ISSUED 08/10/2009 09/14/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: //11-A3 Print Name: fr1.-■■"/1^5 - (% d ( _ N`—� doc: Cond -Elec EL09 -0485 Printed: 09 -14 -2009 CITY OF TUKWILO Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://wwwci.tukwila.wa.us 0 Electrical Permit No. qicti u-rbc Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 4'3 3 Tlf a-' Tenant Name: Property Owners Name: Mailing Address: 8 GAr- Pµa Cra . A-vkw 1/40- rrfl/x'L42 601210 King Co Assessor's Tax No.: 1-1,,o1.-(4- 70r) ID Suite Number: f C_ pj Floor: 'rD00 Loutt-r New Tenant: [ Yes .. No N6, LA7 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: ( AiLHi-MUT S ( -DA iv, wtAl Mailing Address: 121 30 1 - 13111 ST. E -Mail Address: claw i d @ -ts¢— ae p. cow"- Day Telephone: ( 4"1'37 '14 (- (, 6 o 144 00; 1-1"; u.4.7 City Fax Number: State Zip C f2.y) ¥ l - (.37-1 ELECTRICAL CONTRACTOR INFORMATION (-- Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 2P1 0 00 Scope of Work (please provide detailed information): IN7 f2I o 12 TOki'rr 1 i" I &JAM f> f N N So U " M cf-trrOft MALL o O . co u ►2-7 • OP P r ro sAL :— s- rAkRrt►• -r slNQ R+ • Will service be altered? ❑ Yes Type of Use: Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: JI Puget Sound Energy ❑ Seattle City Light No Prot- Adding more than 50 amps? Yes ❑ No ❑ Service Change ❑ Fire Alarm H: Applicalions'Fonns- Applications On Line\l -2009 - Electrical Permit Application doc bh ❑ Remodel Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NE SIDENTIAL SERVICE ❑ New single fam', dwellings $145.60 (including an at • ed garage) ❑ Garages, pools, spas and out dings $78.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $57.00 ea MIILTI- FAMILY AND RES NTIAL REMODEL AND SERVICE CHANGES ❑ Service Chan: or alteration $78 -00 (no added/ red circuits) ❑ Service change with .. ed/altered circuits $78.00 number of as -d circuits $11 -00 ea ❑ Circuits added/altered without s ice change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service ch a $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems 57.00 (alarm, furnace thermostat) Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Tempo . -rvice (residential) $60.00 ❑ Temporary service venerator) $75.00 ❑ Manufactured/mobile hom -rvice $80.00 (excluding garage or outbui ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 : - C '. CAL CONTRACTOR: Signature: Print Name: &91v1 NbtO Y- kJ Mailing Address: g13 ' 3' iA v • IDate Application Accepted: tit / S•tiTP 'Lo I / Day Telephone: City Date Application Expires: Date: v//2-6(0 1 (206) 4-µ �-- loo Wit Twit. State zip H AApplications\Fonms- Applications On Line \1 -2009 - Electrical Permit Application doc bh Staff Initials: .rl 1 Page 2 of 2 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://wwwci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL09 -0485 Address: 2600 SOUTHCENTER MALL TUHW Status: APPROVED Suite No: Applied Date: 08/10/2009 Applicant: CAFE PHO Issue Date: Receipt No.: R09 -01436 Initials: User ID: Payee: JEM 1165 Payment Amount: $416.00 Payment Date: 09/14/2009 11:19 AM Balance: $0.00 MYUNG JO LIM TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 31416B ACCOUNT ITEM LIST: Description 416.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 416.00 Total: $416.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 09 -14 -2009 Cilly1 of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: httn : //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R09 -01249 Initials: JEM User ID: 1165 Payee: PTCC, LLC Payment Date: 08/10/2009 Total Payment: 2,307.86 SET ID: 0810 SET NAME: CAFE PHO SET TRANSACTIONS: Set Member Amount D09 -158 1,934.27 EL09 -0485 104.00 M09 -100 130.84 PG09 -092 138.75 TOTAL: 1,934.27 TRANSACTION LIST: Type Method Description Amount Payment Check 2058 2,307.86 TOTAL: 2,307.86 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 000/345.830 TOTAL: 104.00 2,203.86 2,307.86 PAYMENT RECEIVED (Op 01K RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Project: CAce p 00 Type of Inspection: 7/o0 Address: 2-( 00 ' 1 °� Date Called: ��^^ Special Instructions: Date Wanted: /OY Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Cogag1045 rtAD& OcK r,„1, Inspector: 604 Date: I r� /di / / l El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: s INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 4e, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: C4(6 I) rao Type of Inspection: 00, Address: 2(200 ilfridt/ Date Called: Special Instructions: Date Wanted: Q r m. p.m. Requester: Phone No: rgi Approved per applicable codes. El Corrections required prior to approval. COMMENTS: .K. c6nAdii Coveic cofrilicre 6"1446e, Date: z 01109 I r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1Receipt No.: Inspector: Date: INSPECTION RECORD Retain a copy with permit INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6491-orc 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: /7 _ U CJAih,{` — Lii 3 ta rV•J J Fc}Lr J `k IS 5e6(4, Type of Inspection: l/v ik. 6 A-AsS LiaI k WI) IrJ ST4u1, Address: 2400 �u' Date Called: - fitRt4tti■ oJC-kt.o R.t j? roll,,, �__. Special Instructions: Date Wanted: 0 r � � / a.m. p.m. Requester: Phone No: nApproved per applicable codes. Corrections required prior to approval. COMMENTS: ' — Lii 3 ta rV•J J Fc}Lr J `k IS 5e6(4, P } T - T1R..1? - 6 vioJE kiNitccEsSl & IDtSco44ECT- ik. 6 A-AsS LiaI k WI) IrJ ST4u1, T3Q.0 -o C w c or ‘,5 k ' .ttx - K.Q. ,5C -kt. l -> IA/ F2 Z- k. — w si k“... cie._ E l'6.1134/41-5 - fitRt4tti■ oJC-kt.o R.t j? roll,,, KO -RN 1) 6- Askr - 1 r 1 P L -arts To IhlwiP E AW&. Inspector: Date: 12-101(07 e m $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: set_ 1601- Ol INSPECTION NO. PERMIT NO. /_ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 3 INSPECTION RECORD Retain a copy with permit Project: '^J r6 ruk, Type of Inspection: ! oo7- ` Address:200 ' l�'-`� Date Called: Special Instructions: Date Wanted: /D /t. 21 P.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: �JK t - ` t )tJbIPJ(/ wG,i C®dDJcaD& 5a. 144.1 it- 0114 fr-1045/O SCI kizehkr Inspector: $60.00 REIN 7 ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: /0/1-7/07 Receipt No.: Date: INSPECTION RECORD Retain a copy with permit �LQ _O, °(r( INSPECTION NO. POINT NO. CITY OF TUKWILA BUILDING DIVISION le-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project: C4 , re Yt-1-0 Type of Inspection: r/ loo Address: ?�vop 5 -�• JIM, Date Called: ,- Special Instructions: Date Wanted: /0 02— .m. p.m. Requester: Phone No: ❑ Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 'CA NJ (A) Date: 10/0 2 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee dust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION RECORD 6,407'0142c. Retain a copy with permit INSPE ION NO. PEIT NO. CITY OF TUKWILA BUILDING DIVISION 'g--- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project: C4(4. l 140 Type of Inspection: 700 J Address: 00 Date Called: Special Instructions: Date Wanted: 07 30 • Requester: Phone No: 0 Approved per applicable codes. Ij Corrections required prior to approval. COMMENTS: pa 0 Cody Aw NI be■S ArID Alc>1.-194 CyCabi BA-c4 Wesr coR2IDoI� wAv,-(PrNdEcs ay+n i5f.h.Jksc") Inspector: Date: 01 07 D $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: •PERMT COORD COPY 1111 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL09 -0485 PROJECT NAME: CAFE PHO DATE: 08 -10 -09 SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -8 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENT :lir, Bul dinvision+ Public Works n Fire Prevention Structural n Planning Division nPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08-11-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route 154 Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-08-09 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by L&tl to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company HANKOOK INC 2536618476 34300 13TH PL SW FEDERAL WAY WA 98023 KING Corporation UBI No. 602596850 Status ACTIVE License No. HANKOI *945LW License Type ELECTRICAL CONTRACTOR Effective Date 6/16/2006 Expiration Date 6/16/2010 Suspend Date Specialty 1 GENERAL Specialty 2 UNUSED Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HANKO* *98707 HAN KOOK ELECTRIC ELECTRICAL CONTRACTOR GENERAL UNUSED 9/27/2002 9/27/2006 OUT OF BUSINESS MASTER ELECTRICIAN INFORMATION License LEE *CCY978QG Name LEE, CHONG YUN Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date LIM, MYUNG JO AGENT 06/16/2006 LIM, MYUNG JO PRESIDENT 06/16/2006 LIM, CHONG Y SECRETARY 06/16/2006 LIM, HYUNG OK VICE PRESIDENT 06/16/2006 Bond Information Bond Bond Company Bond Account Effective https: // fortress .wa.gov /lni/bbip /Detail.aspx Expiration Cancel Impaired Bond Received 09/14/2009 LIGHTING FIXTURES 0 FLUORESCENT FLUORESCENT W /BATTERY BACKUP FLUORESCENT TROFFER RECESSED ACCENT LIGHT I-o-1 FLUORESCENT STRIP WALL SCONCE - . RECESSED CAN LIGHT /SURFACE MOUNT ® RECESSED CAN W /BATTERY BACKUP 0 ❑ H.LD., FLUORESCENT OR INCANDESCENT O� fO WALL MOUNTED y TRACK LIGHTING ® EXIT SIGN EMERGENCY LIGHTING SWITCHING 5a 5 SINGLE POLE THREEWAY FOURWAY LOCKING DIMMER MANUAL MOTOR STARTER WITH THERMAL OVERLOADS TIMER PILOT LIGHT VARIABLE SPEED FAN CONTROLLER SWITCH WITH LED PILOT LIGHT OCCUPANCY SENSOR (a,b,c) DENOTES SWITCH LEGS POWER DEVICES PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED TRANSFORMER FLOORBOX WITH DUPLEX RECEPTACLE 0 MOTOR CONNECTION. (NUMBER = HORSEPOWER) DISCONNECT SWITCH DISCONNECT SWITCH - FUSED COMBINATION STARTER /DISCONNECT MAGNETIC STARTER EQUIPMENT CONNECTION SPECIAL RECEPTACLE e- CLOCKBOX RECEPTACLE. DUPLEX RECEPTACLE ofta QUADRAPLEX RECEPTACLE PUSHBUTTON CONTROLLER 0 JUNCTION BOX CB FIRE ALARM IFI4 MINI HORN /STROBE COMBINATION MINI HORN ® MANUAL PULL STATION SMOKE DETECTOR © SPEAKER, FIRE ALARM ® HEAT DETECTOR MAGNETIC DOOR HOLD OPEN FLOW SWITCH TAMPER SWITCH LOW PRESSURE SWITCH RELAY CONFIRM MTG. HT. W /ARCFO -i DUCT SMOKE DETECTOR CONNECTION (REMOTE TEST, W/ LED) Cr laa 10" EXTERIOR BELL - WEATHER PROOF ®. KNOX BOX STROBE ONLY i RACEWAY TELEPHONE DATA �--r� HOMERUN TO PANEL. P1 -5 (INDICATES PANEL AND CIRCUIT NUMBER) DATA OUTLET (4) RJ45 JACKS AND 4 -4PR CATEGORY 5 CABLES -Hi NUMBER OF CONDUCTORS ®- TELEPHONE /DATA OUTLET - (2) RJ45 JACKS #1O-'- (WIRE GAUGE OTHER THAN AWG #12) AND 2 -4PR CATEGORY 5 CABLES r\ 1 PHASE CONDUCTOR .:NEUTRAL CONDUCTOR I 11 ' - GROUND CONDUCTOR V . TELEPHONE OUTLET PAINTED 3/4" PLYWOOD BACKBOARD ELECTRICAL GENERAL NOTES: 1) ALL RECEPTACLES AND SWITCHES SHALL BE FLUSH MOUNTED FOR ALL AREAS. U.O.N. 2) THE ELECTRICAL DRAWINGS. ARE GENERALLY DIAGRAMMATIC. THE ELECTRICAL INSTALLATION SHALL BE COORDINATED WITH ALL OTHER TRADES SO THAT INTERFERENCES BETWEEN THE ELECTRICAL INSTALLATION AND ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND EQUIPMENT INSTALLATION WILL BE AVOIDED. 3) REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE RELATED PARTITIONS, CABINET AND CASE WORK AND BUILT -IN DETAILS. 4) ALL WIRING TO BE SIZE #12 AWG UNLESS NOTED OTHERWISE. 5) CONTRACTOR SHALL PROVIDE ALL DISCONNECTS TO MEET LOCAL CODES. 6) 7) CONTRACTOR SHALL VERIFY ALL DOOR SWINGS BEFORE INSTALLING LIGHT SWITCHES. ALL LIGHT SWITCHES TO BE INSTALLED ON STRIKE SIDE OF DOOR UNLESS SPECIFICALLY NOTED OTHERWISE. ALL FINAL CONNECTIONS SHOWN ON THE DRAWINGS ARE ACTUAL REQUIREMENTS OF THE EQUIPMENT AND ARE SHOWN IN THEIR APPROXIMATE LOCATION. 8) ALL MOTOR STARTERS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR FURNISHING THE EQUIPMENT AND INSTALLED, WIRED AND CONNECTED BY ELECTRICAL CONTRACTOR. 9) AUDIO/VISUAL INDICATOR SHALL BE INSTALLED ABOVE THE FIRE ALARM PULL STATION WHERE APPLICABLE AT APPROXIMATELY 6" BELOW CEILING OR +80" A.F.F. WHICHEVER IS LOWER. 10) ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHERPROOF AND RAIN TIGHT. 11) COORDINATE ALL LIGHTING WITH MECHANICAL AND PLUMBING EQUIPMENT. 12) 13) 14) 15) CONTRACTOR TO VERIFY THAT EQUIPMENT WITH CIRCUIT BREAKERS AS LOCAL DISCONNECT MEANS IS HACR RATED. IF NOT, PROVIDE DISCONNECT SWITCH PER N.E.C. MOUNTING HEIGHT OF ALL DEVICES SHALL CONFORM WITH 2005 N.E.C., STATE ELECTRICAL CODE, LOCAL CODES AND ADA. UNLESS OTHERWISE INDICATED ON THE DRAWINGS. - RECEPTACLES: -15 "; 48" AFF TO CL - SWITCHES: . 48" AFF TO CL ;REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLY DESIGN NUMBERS. COORDINATE ALL DESIGN WORK WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. FINAL DETERMINATION OF FIRE DAMPERS AND OTHER FIRE STOPPING REQUIREMENTS SHALL BE BASED ON LOCAL CODE REQUIREMENTS. 16) ELECTRICAL SYSTEM EQUIPMENT AND COMPONENTS SHALL BE U.L LISTED, AND BE IN COMPLIANCE WITH THE REGULATIONS OF THE STATE AND LOCAL ENFORCING AGENCIES. 17) THE ELECTRICAL CONTRACTOR SHALL REFER TO ` AND COORDINATE THE LOCATION OF ALL AREA/ OCCUPANCY SEPARATION WALLS WITH THE ARCHITECTURAL DRAWINGS AND DETAILS. 18) ALL CONDUIT, ETC. PENETRATIONS THROUGH THE BUILDING SHALL BE FIRE /SMOKE STOPPED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES FIRE RESISTANCE WITH HOURLY RATINGS FOR THROUGH-PENETRATION ET ATION FIRE STOPS SYSTEM VOLUME 2 OR SHALL BE INSTALLED ED IN STRICT ACCORDANCE PER THE MANUFACTURERS U.L. LISTINGS (3M-OR EQUAL). COORDINATE WITH GENERAL CONTRACTOR PRIOR TO BIDDING. 19) CONTRACTOR IS TO BRING UP. ANY DISCREPANCIES. AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN, BUT ARE REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM, AND WHICH AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT. AFTER AWARDING THE CONTRACT, ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH AFOREMENTIONED DISCREPANCY ITEMS AT NO ADDITIONAL COST TO THE OWNER. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO " DETERMINE THE EXACT IMPACT OF THE RETROFIT TO THE ELECTRICAL SYSTEM AND SHALL INCLUDE IN HIS BID ALL THE WORK WHICH MIGHT NOT BE SPECIFICALLY MENTIONED BUT IS REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM READY FOR OWNER'S BENEFICIAL USE. ALL WORK SHALL CONFORM TO U.L., 2008 NEC., N.F.P.A., AND ALL OTHER CODES OF JURISDICTION WHICH ARE APPLICABLE TO THIS ELECTRICAL INSTALLATION SEE ALSO "TENANT CRITERIA MANUAL ", FOR ADDITIONAL INFORMATION CONCERNING THE . RESPONSIBILITIES OF THE ELECTRICAL CONTRACTOR. READ PRIOR TO BID. ALL ELECTRICAL WORK SHALL CONFORM TO U.L. STANDARDS, N.E.C., N.F.P.A. AND ALL OTHER CODES OF JURISDICTION WHICH ARE APPLICABLE TO THIS ELECRICAL INSTALLATION. SEPARATE PERMIT REQUIRED FOR: Mechanical ❑ Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION ABBREVIATIONS AC AIR 'CONDITIONING AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT A AMPERE AWG AMERICAN WIRE GAUGE BLDG BUILDING BKBD BACKBOARD BKR BREAKER CAB CABINET C CONDUIT CB CIRCUIT BREAKER CKT CIRCUIT CCTV CLOSED CIRCUIT TELEVISION CO CONDUIT ONLY CT CURRENT TRANSFORMER DIST DISTRIBUTION (E) EXISTING EF EXHAUST FAN ENCL ENCLOSURE EWC ELECTRIC WATER COOLER F/A FIRE ALARM FBO FURNISHED BY OWNER FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR F FUSE GFI GROUND FAULT INTERRUPTER HTR HEATER IG ISOLATED GROUND J -BOX JUNCTION BOX LTG LIGHTING MTD MOUNTED M METER NIC NOT IN CONTRACT MLO MAIN LUGS ONLY (N) NEW NL NIGHT LIGHT (UNSWITCHED) OL OVERLOAD. PNL P REC SMR SW SWBD TEL TYP TV UON UV UG PANEL POLE RECEPTACLE SURFACE METAL RACEWAY SWITCH SWITCHBOARD TELEPHONE TYPICAL TELEVISION UNLESS OTHERWISE NOTED UNIT VENTILATOR UNDERGROUND WATT WH WATT HOUR METER WP WEATHERPROOF XMFR TRANSFORMER V VOLT Y WYE LANDLORD NOTES PRIOR TO MAKING ANY PIPE ROOF PENETRATION OR CORE DRILL OR POSITIONING OF ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS AS INDICATED ON LANDLORD APPROVED PLANS AND APPROVED BY LANDLORD'S ` CONSTRUCTION FIELD COORDINATOR. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE A FIRE WATCH AND. A PORTABLE FIRE EXTINGUISHER (MIN SIZE 2A :20BC) WHEREVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN TENANT SPACE FOR AT LEAST (1) HOUR AFTER COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORTS, ETC. SHALL BE FASTENED TO BAR JOISTS OR BEAMS. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. EXPOSED CONDUITS SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH, OR AT RIGHT ANGLES TO, COLUMN LINES OR BEAMS AND BE SEPARATED AT LEAST (3) INCHES.; FROM WATER OR GAS LINES. ALL TENANT EQUIPMENT ON ROOF SHALL BE LABELED WITH TENANT NAME AND SUITE NUMBER. ALL TENANT EQUIPMENT MUST BE LOCATED IN THE LANDLORD APPROVED LOCATION. ALL ROOF PENETRATIONS SHALL BE MADE AT TENANT'S EXPENSE BY THE LANDLORD APPROVED ROOFING CONTRACTOR. ALL WATERPROOFING SHALL BE DONE AT TENANT'S EXPENSE BY THE LANDLORD APPROVED WATERPROOFING CONSULTANT. ON COMPLETION, TENANT SHALL OBTAIN AT TENANT'S EXPENSE, A SPECIAL INSPECTION SIGN -OFF FROM LANDLORD'S ROOFING CONTRACTOR AND SHALL DELIVER PROOF OF SIGN -OFF TO THE LANDLORD TENANT COORDINATOR. TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE- EIGHTH INCH (1/8 ") THICK PLASTIC, BLACK ON WHITE WITH ETCHED LETTERS. MINIMUM SIZE SHALL BE ONE (1) INCH WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. REVISIONS' PLAN INDEX: El GENERAL NOTES, SCHEDULES, AND PLAN INDEX E2 FLOOR PLAN -. LIGHTING E3. FLOOR PLAN POWER /COMMUNICATIONS E4 RISER DIAGRAMS, PANEL SCHEDULES E_SPEC SPECIFICATIONS REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division: NOTE Revisions will require a new plan submittal' and may include additional plan review fees. Pe PA 70 j Ci `ILDT p Abossein Engineering, L.L.C. MECHANICAL ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: 425 462 -9441 FAX: (425) 462 -9451 E -Mail: cservice@abossein.com OIn www.abossein.com I EXPIRES 810/10 PROJECT NAME CAFE PHO 633 Southcenter Mall S ace FC -8 ukwila, WA 98188 ISSUED FOR PERMIT ONLY NOT FOR BID OR CONSTRUCTION =` DRAWING TITLE it No, . ;i,-o 1 -titi Plan review approval is subject to errors and omission GENERAL Approval of construction documents ENER AL NOTES, p does not authorize the violation of any adopted code or ordinance. ReceigCHEDULES & of approved Field Copy and conditions is acknowledge PLAN INDEX Date: City Of lbkwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 10 2009 PERMIT CENTER JOB NUMBER 29047 DRAWN BY GN CHECKED BY AVA 7 -17 -09 7 -27 -09 ')LORD REVIEW SET AIT SET ISSUED DATE DESCRIPTION E01 (OF 5) 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Revised July 2007 Project Info Project Address SOUTHCENTER RESTAURANT Date 7/9/2009 SOUTaCENTER MALL, SPACE FC -8 For Building Department Use TUKWILA, WA Applicant Name: - Applicant Address: Applicant Phone: _ Q Project Description ❑ New Buildin ❑ Addition Alteration -' Plans Included Project s Indicate controls i (Sect Ens 1513) including commissioning requirements on plans. 0 Prescriptive Q� Lighting Power Allowance Q Systems Anal sis Compliance Option Y (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exce ❑ No changes are being made to the lighting check appropriate box - . 1 ( sec 1132.3) ❑.Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location Allowed floor /room no. Occupancy Description 2 ** Area in ft2 (floor/room Watts per ft Allowed x Area RESTAURANT - 1OFT CEILINGS 1.33 455.0 605.2 RESTAURANT 18FT CEILINGS 1.55 515.0 798 3 FOOD PREP AREA EXEMPTED PER 1512.1(4) SEE FOOTNOTE 5, TABLE 15 -1 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1403.4 Proposed Lighting Wattage Location Number of Watts/ Watts (floor /room no.) Fixture Description Fixtures Fixture ` Proposed Ll - DECORATIVE WALL SCONCE 2 60.0 120.0 L2 - DECORATIVE PENDANT (LARGE) 2 100.0 200.0 L3 VANITY FIXTURE (3) 13W CFL 2 45:0 90.0 L4 - DECORATIVE PENDANT (SMALL) 8 35.0 280.0 L5 - LINE VOLTAGE .TRACK (VIA CURRENT LIMITER) 1 360.0 360.0 L6 RECESSED CAN. (1) 32W CFL 9 35.0 315.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1365.0 Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture; Tamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only the default table in the NREC Technical Reference Manual may also be used For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. ELECTRICAL FIXTURE SCHEDULE MARKING BALLAST FIXTURE TYPE LAMPS VOLTS WATTS DESCRIPTION LOCATION OFCI WALL SCONCE - TO BE 60 WATTS OR LESS TO ENSURE LI TBD OWNER FURNISHED, CONTRACTOR INSTALLED TBD 120 60 COMPLIANCE WITH NREC OFCI PENDANT - TO BE 100 WATTS OR LESS TO ENSURE L2 TBD OWNER FURNISHED, CONTRACTOR INSTALLED TBD 120 100 COMPLIANCE WITH NREC OFCI VANITY FIXTURE - TO BE 45 WATTS OR LESS TO ENSURE L3 TBD OWNER FURNISHED, CONTRACTOR INSTALLED TBD 120 45 COMPLIANCE WITH NREC OFCI PENDANT - TO BE 35 WATTS OR LESS TO ENSURE L4 TBD OWNER FURNISHED, CONTRACTOR INSTALLED TBD 120 35 COMPLIANCE WITH NREC TRACK SYSTEM TO BE FED VIA CURRENT LIMITER TO ENSURE L5 N/A JUNG; SINGLE TRACK WIT218BL HEADS 50W PAR 30 120 50 COMPLIANCE WITH NREC, #JUNO TCL3 6" DIAMETER RECESSED CAN WITH LENSED REFLECTOR, FULLY L6 ELEC UTHONIA; LP6F- 26- 42TRT- MVOLT -6L4 (1) 32W CFL UNIV 34 ENCLOSED AND WET LISTED 2X4 RECESSED LENSED TROFFER FOR USE IN FOOD PREP /BACK L8 ELEC LITHONIA; GT8- 232- Al2- MVOLT- GEBIOIS (2) 32W T8 UNIV 62 OF HOUSE 2X4 RECESSED LENSED TROFFER FOR USE IN FOOD PREP /BACK L8E ELEC LITHONIA, GT8- 232- Al2- MVOLT -GEBI OIS -EL (2) 32W T8 UNIV 62 OF HOUSE. WITH BATTERY BACKUP X1 LITHONIA, LHQM- S -W -1 -R LED & 5W 120/277 3.3 EXIT SIGN /EMERGENCY LIGHTING UNIT, WITH BATTERY BACKUP XZ LITHONIA, ELM2 5W 120/277 1.2 EMERGENCY LIGHTING W /BATTERY BACKUP Abossein Engine erin�, L.L.C. MECHANICAL ELECTRICAL CIVIL LEED FIRE PROTECTION 2100 112THA AVE. NE ,LE BEI i VU EW A .98004.. PH. — (425) 462 9441 FAX: (425) 462 -9451 E Mall, cservice@abossein.com www.abossein.com COOLER LIGHTING/SWITCHES SUPPLIED BY MANUFACTURER,. SEE SHEET E03 R POWER/LIGHTING CIRCUIT(S) IEXPIRES 8/10/10 TRA C CURRENT LIMITER TAGS 3A TRAC CURRENT LIMITER JUNO TCL3 PROJECT NAME CAFE PHO 633 Southcenter Mall Space FC -8 Tukwila, WA 98188 17 ®l7 W17 ®17 LIGHTING CONTROL CONSULT OWNER'S REPRESENTATIVE IN FIELD FOR TIME /OPERATION SCHEDULING. PROVIDE SEPERATE SURFACE MOUNT ENCLOSURES FOR CONTACTORS. SIZE PER NEC. ISSUED FOR PERMIT ONLY. NOT FOR BID OR CONSTRUCTION TIMER POWER TORK TIMESWRCH IEW101 B OR EQUAL`` LEVITON ODS10 -ID PIR - O CGU P-A N CY..S EN SO Rte-. OR EQUAL. (TYP.) 120V NOTE: r ALL JOINTS IN UNI -STRUT ARE TO BE SECURELY FASTENED USING HEAVY DUTY JOINING PLATES: TORK TIMED OVERRIDE SWITCH SS20 OR EQUAL. SET TO 2HRS. DRAWN BY LIGHTING CONTACTOR WITH 30A CONTACTS, SQUARE D TYPE LX ELECTRICALLY HELD, OR EQUAL 20A1P 20A1P 20A1P DINING LIGHTING CANS /PENDANTS DINING LIGHTING TRACK SPRING NUT— FLAT WASHER (2) NUTS (2) NUTS FLAT WASHER - STRUCTURAL' MEMBER 1 -1/2" DEEP P1000 UNISTRUT - SP AT TOP OF BAR `JOIST. NOT TO BE SECURED TO ROOF DECKING. ONLY TO BE SECURED TO UNISTRUT /STRUCTURAL MEMBERS. 3/8" ALL - THREADED ROD Sae CS$ SWITCHBANK LAYOUT: SWITCH 'a' - BACK ROOM LIGHTING SWITCH 'b' TIMECLOCK OVERRIDE CONTROL FOR DINING LIGHTING. SEE LIGHTING CONTROL DIAGRAM THIS SHEET FOR INFORMATION. 7 -17 -09 LANDLORD REVIEW SET 7 -27 -09 PERMIT SET ALL EXIT LIGHTING FIXTURES TO BE CONNECTED TO LOCAL LIGHTING CIRCUIT AHEAD OF ANY AND ALL SWITCHING. ALL EXIT FIXTURES HAVE BATTERY BACKUP. NIGHTLIGHT FIXTURE. FIXTURE TO OPERATE 24HRS /DAY FOR SECURITY PURPOSES. MOUNT TRACK LIGHTING ON UNISTRUT ©10' -0" TYP. COORDINATE STRUT ANCHOR LOCATIONS WITH LANDLORD. SPRING NUT LIGHTING TRACK /FIXTURE ISSUED DATE DESCRIPTION 1 -1/2" DEEP P100 UNISTRUT SPARE 120V UNI —STRUT DETAIL SCALE: NONE RECEIVED CITY OF TUKWiLA' AUG . 1 0 2009 PERMIT CENTER KITCHEN EQUIP /MECH EQUIP SCHEDULE UNIT NUMBER UNIT DESCRIPTION WALK IN COOLER WALK IN FREEZER UNIT HP UNIT MCA UNIT FLA VOLTS /PHASE 208V 1P TBD 208V 1P WATER HEATER 43.3 480V 3P REACH IN REFRIGERATOR 120V 9 P; DISHWASHER 11.4 120V 1P E16 REFRIGERATED PREP TABLE 120V 1P REFRIGERATED PREP TABLE 120V 1P E18 REFRIGERATED WORKTOP 120V 1P ICE MACHINE 120V 1P E26 GLASSWARE WASHER BACK BAR COOLER BEER COOLER/DISP. 120V 1P 120V 1P 120V1P FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION FROM J -BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC. MAX LENGTH 6 FEET. NO BX, ROM EX, AC, MC, ETC. ALLOWED. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES, PARALLEL OR IN RIGHT ANGLES TO BUILDING STRUCTURE. DO NOT LOOP EXCESS FLEXIBLE CONDUIT IN CEILING SPACE . OR WALL CAVITY.' NO FLEXIBLE CONDUIT IS PERMITTED IN DEMISING WALLS. CONFIRM ALL DISCONNECT /FUSE SIZES WITH UNIT NAMEPLATES AS INSTALLED IN FIELD. FIRE ALARM NOTE: TENANT SHALL INSTALL WITHIN TENANT'S PREMISES A FIRE ALARM SYSTEM OR COMPONENTS AS DELINEATED THROUGH DESIGN DOCUMENTS ISSUED BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR (AT TENANT'S EXPENSE) GUARDIAN SECURITY 9435 PROVOST RD NW SILVERDALE, WA 98383 PHONE: - 360 - 692.3738 EMAIL: BOB VEZZANI bvezzani @guardicnsecurity.com MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BEI,LEVUE, WA 98004 PH: (425) 462 -9441 FAX (425) 462 -9451 E -Hail: cservice@abossein.com www.abossein.com P.O.S. /CASH REGISTERS 120V 1P HP -1 ROOFTOP HEAT PUMP NTERIOR AIR HANDLER 21.9 26.8 480V 3P 480V 3P KITCHEN HOOD EXHAUST FAN 208V 3P DISHWASHER HOOD EXHAUST FAN 120V 1P 30AS 20AF -5,7 Q WALK_IN_.LTS, P-9—DOOR HTR PANEL P PANEL H 1E5 30AS 20AF P -1,3 EXPIRES 8/10/10 -2,4,6 P -16,18 P- 10,12,14' LOCATE XFMR ABOVE I I GR D CEILING, HANG FROM STRUCTURAL STEEL BEAM.' EST. 400LBS PROJECT NAME ANSU P -32 P -21 VIA TIM FAN (ROOF) CONFIRM,' COCATION OF ALL ROOFTOP EQUIPMENT WITH MECH. CONTRACTOR ISSUED FOR PERMIT ONLY NOT FOR BID OR CONSTRUCTION DRAWING TITLE POWER PLAN SCALE: 1 /4" = 1' -0" FIRE SUPPRESSION SYSTEM CONNECTION NOTES 1. E.C. SHALL PROVIDE ALL RELAYS AND INTERLOCK WIRING AS REQUIRED FOR SHUT DOWN OF ALL ELECTRICAL DEVICES LOCATED IN THE EXHAUST HOOD FIRE PROTECTION ZONE ON FIRE SUPPRESSION SYSTEM ACTIVATION. 2. E.C. SHALL PROVIDE. ALL RELAYS AND INTERLOCK WIRING AS REQUIRED TO CLOSE ALL GAS SUPPLY 1 20V SOLENOID VALVES IN THE KITCHEN ON FIRE SUPPRESSION SYSTEM ACTIVATION. FLAG NOTES: E.C. SHALL PROVIDE ALL RELAYS AND INTERLOCK WIRING AS REQUIRED TO SHUT DOWN MAU -1 WHILE SIMULTANEOUSLY STARTING EXHAUST FAN KEF -1 ON FIRE SUPPRESSION SYSTEM ACTIVATION. E.C. . SHALL PROVIDE ALL RELAYS AND INTERLOCK WIRING AS REQUIRED FOR CONNECTION TO MICROSWITCH IN FIRE SUPPRESSION SYSTEM CONTROL PANEL FOR WORK DESCRIBED IN THESE NOTES. E.C. SHALL PROVIDE ALL RELAYS AND INTERLOCK WIRING AS , REQUIRED TO ACTIVATE FIRE ALARM SYSTEM GENERAL ALARM ON ACTIVATION OF FIRE SUPPRESSION SYSTEM. WIRING BETWEEN TERMINAL BLOCKS IN INDIVIDUAL EQUIPMENT CONTROL PANEL SHALL BE BY RESPECTIVE TRADES NOT BY FIRE SUPPRESSION SYSTEM INSTALLER WHO SHALL PROVIDE TECHNICAL ASSISTANCE TO ELECTRICAL, MECHANICAL AND FIRE ALARM SYSTEM INSTALLERS AS REQUIRED FOR A COMPLETE AND OPERATING FIRE SUPPRESSION SYSTEM MEETING THE APPROVAL OF ALL AUTHORITIES HAVING JURISDICTION. PROVIDE (1) 1" POWER CONDUIT AND (1) 1" PHONE /DATA CONDUIT. COORDINATE SAWCUTTING - LOCATION & TIME WITH LANDLORD PROVIDE ALL CUTTING, CORING, BACKFILL AND PATCHING OF EXISTING CONCRETE FLOOR REQUIRED FOR INSTALLATION OF CONDUITS. RECEIVED CITY OF TUKWILA AUG 10 2009 JOB NUMBER 29047 INTEGRATE HOOD ANSUL SYSTEM WITH BUILDING FIRE ALARM (SEE FIRE ALARM NOTE, THIS SHEET). FIELD VERIFY EXACT LOCATIONS AND REQUIREMENTS OF CUSTOM BUILT WALK IN UNITS. COORDINATE WITH WALK IN INSTALLER FOR ELECTRICAL CONNECTIONS. PROVIDE CLOCKBOX RECEPTACLE AND CATV JACK FOR WALL MOUNTED TV © +90" P.O.S. CASH REGISTER LOCATION. PROVIDE POWER AND (2) CAT5E 4PR CABLES /JACKS AT EACH LOCATION. ROUTE CAT5E TO PHONE BACKBOARD ABOVE ELECTRICAL PANELS KITCHEN EXHAUST FAN AND MAKEUP AIR UNIT LOCATED ON ROOF. CIRCUIT THROUGH HOOD CONTROL PANEL. SEE CAPTIVE AIRE WIRING DIAGRAMS. DISHWASHER EXHAUST FAN. CIRCUIT THROUGH PILOT LIGHT SWITCH LOCATED AT HOOD. ROOFTOP HVAC UNIT. CONFIRM LOCATION WITH INSTALLER. PROVIDE (1) 3/4" CONDUIT FROM UNIT TO TENANT SPACE FOR CONTROL (CONTROL BY MECH) 7 -17 -09 LANDLORD REVIEW SET 7 -27 -09 PERMIT SET lo PROVIDE J- BOX /POWER ` FOR SIGNAGE. CONFIRM LOCATION AND REQUIREMENTS W /ARCH. CIRCUIT THROUGH TIMECLOCK /CONTACTOR. SEE SHEET E02. ISSUED DATE DESCRIPTION QUAD RECEPT. COMMUNICATIONS BACKBOARD LOCATE ABOVE GRID CEILING IN BACKROOM #6 CU Available Fault Current Calculation # Fault Current 1 =kVAx 1000= trans. RA E x1.732 amperes . : kVA E trans. FLA Isca = trans. FLA x 100 = transformer - Z Isca = ampere short - circuit current RMS symmetrical. Isca Point to Point Method factor = 1.732 x L x I NxCxEL -L 45 208 125 208 =1 31X 4,164 amperes Length (distance) L =1 81 (ASC) Isca = 4,164 1 conductors per phase N = Phase conductor constant C = Volt Line to Line E L - L f= Neutral conductor constant C Volt Line to Neutral E L - x = Multiplier M = 1 + f Fault Current at Service Equipment Isca x M = fault current at terminals of main disconnect L - L Isca x M = fault current at terminals of main disconnect L - N = Line to Une Line to Neutral f= M 1 8,925 3 Phase 208/120 Copper in EMT Phase Conductor 208 Volt 0.031 Neutral Conductor 120 Volt 0.062 8,9251 0.970 0.941 4,038 amperes 3,920 amperes I' WEE Available Fault Current Calculation 2 Fault Current at Landlord Distribution: I =kVAx 1000 = trans. FLA E x 1.732 Isca = trans. FLA x 100 1 29,8091 amperes kVA = E trans. FLA transformer Z = Isca = ampere short - circuit current RMS symmetrical. ' Isca Point to Point Method 'f 'factor = ' 1.732 x L x 1 NxCxEL -L Multiplier Length (distance) L = (ASC) Isca = # conductors per phase N = Phase` conductor constant C = Volt Line to Line E L - u _ f Neutral conductor constant C = Volt Line to Neutral E r. - • = f = 1 M =1 +f' Fault Current at TENANT PANEL H . Isca x M = fault current at terminals of main disconnect L L = Isca x M = fault current at terminals of main disconnect L - N = Line to Line Line to Neutral M = M = 480 I -I 3501 29,809 1 12,122 X amperes 3 Phase 480 /277 AL MC Phase Conductor 480 Volt 3.105 12,1221 Neutral Conductor 277 Volt 6.214 ' 1 0.244 0.139 7,261 amperes 4,132 amperes 1 250kCMIL1 1 250kCMIL1 PROVIDE 1" CONDUIT TO LANDLORD CABLE TRAY LOCATED IN UTILITY CORRIDOR. (FIELD LOCATE /COORDINATE WITH LL) PROVIDE (4) CAT5E 4PR PLENUM RATED CABLES TO LANDLORD TELEPHONE ROOM /BACKBOARD. FIRE CAULK ALL CORRIDOR PENETRATIONS. PHONE RISER DIAGRAM NEARBY GROUNDIND ELECTRODE, PREFERABLY STRUCTURAL STEEL NEC 250- 30(a)3 DO NOT GROUND TO COLD WATER PPE EQUIPMENT GROUNDING CONDUCTOR 480V. NEUTRAL • EXOTHERMIC WELD OR SPLIT -BOLT CONNECTION MAIN BONDING JUMPER • 208Y 120V INSULATED NEUTRAL TERMINAL •• GND DRY TYPE TRANSFORMER XFMR GROUNDING DETAIL NOT TO SCALE NOTES: PANELBOARD LOCATION:BACKROOM PANEL H LOAD DISTRIBUTION FEED FROM: LANDLORD METER CENTER FEEDER: 200 AMP 3P4W + GND PH REC LTG EQP HTG KIT CKT DESCRIPTION PH AMP POLE LOAD kVA AMP: 225 VOLTS: 480/277 PHASE ` 3 WIRE 4 BUS TYPE: CU A.I.C.: 14k M.L.O.: MAIN CB: 200 FLUSH: SURFACE: XXX GND. BAR: XXX ISO GND: 200% NEU: FEED THRU: DBL LUG: TOP FEED: BTM FEED: A B C A B C A B C A B C A B C A B C A B C 7.40 1.56 1 3 5 7 9 11 13 15 17 19 21 23 25, 27 29 HVAC UNIT - INTERIOR A B C A 8 C A B C A B C A B C 30 3 7.40 7.40 1.56 - - - 7.40 7.40 1.56 WALK IN COOLER COMPRESSOR - - 7.40 635 1.56 HVAC UNIT - EXTERIOR 30 3 6.05 6.05 1.20 WALK IN LIGHTS/DEFROST 20 1 6.05 6.05 SPARE - - 6.05 SPACE 20 1 0.60 SPACE 20 1 0.60 0.60 SPACE 20 1 0.60 0.60 SPACE 20 1 0.60 075 SPACE 20 1 0.75 SPACE 20 1 SPACE 20 1 SPACE 20 1 SPACE 20 1 SPARE 20 1 SPARE 20 ` 1 SPARE 20 1 2.28 HOOD EXHAUST /MAKE UP AIR FANS 30 3 2.28 2.28 - - 2.28 2.28 2.28 :❖:❖:• •.•.•.••.. •••❖:•i•::.•••OOO:::•.:•:.0.0.4 .•••...•.•..••.•.. •• :::::•: .•••..••.•••.••••..••••••..••••....•••..••.•••••••• vOw??.. OOOOOO:: • OO. m.,; 4 ❖ : ❖ :❖ :•• . .-.-•O,;ve :•:: •.•...4.4 •••...•.•••••••••.••••••••••`.. •••••.... • B C A B C A B C A 8 C A B C A B C A 8 C ,•...•.•, 20GFI..._;._._._..._ :❖. ❖:•:.. ;• ;r.-.;. ;rrrr• .• AO•••• v.•r• x,N, •• 4.4.,i piv,- ❖. ❖•••••O•• ❖.••O••••❖••.O A B C A B C A B C A B C A B C 12.00 1.10 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 WATER HEATER (PROVIDE LOCKOFF) A B C A B C A B C A 8 C A B C 60 3 12.00 1.80 12.00 20 1 1.80 - 12.00 12.00 20GFI 1 0.36 - - 12.00 0.72 0.60 3.13 20GF1 5.54 PANEL P VIA XFMR 70 3 9.99 0.72 1.85 2.28 20GF1 7.16 - - - 12.01 0.36 0.80 2.28 20GFI 7.23 1.02 - 10.67 0.92 REFRIGERATED PREP TABLE 20GFI 1 SPACE 0.36 GCO'S - BACKBAR AREA 20GF1 1 SPACE FEEDER T.C.L. LOAD (kVA) SPARE 20GFI SPACE 0.54 FEEDERT.C.L, LOAD (kVA) RECEPTACLES - BATHROOMS, CORRIDOR 20 1 SPACE 1.20 REFRIGERATED PREP TABLE 20GFI 1 SPACE REC 1.8 LTG 3.3 EQP 7.7 HTG KIT 19.9 1.40 REACH IN REFRIGERATOR 20GFI SPACE 1.40 REC 1.8 LTG 3.3 EQP 43.7 HTG 40.4 KIT 19.9 1.36 DISHWASHER (PROVIDE LOCKOFF) " 20 1 SPACE 1.65 ICE MACHINE (PROVIDE LOCKOFF) 20 1 SPACE 0.40 ANSUL SYSTEM/GAS VALVE POWER 20 1 SPACE 0.50 EXHAUST HOOD LIGHTING 20 1 0.50 TOTAL 32.7 0.20 EXHAUST HOOD CONTROL CIRCUIT 20 1 0.20 FEEDER DEMAND kVA - 26.5 AMPERES 73.6 TOTAL 109.0 0.45 DISHWASHER HOOD FAN 20 1 0.45 0.18 FEEDER DEMAND kVA 102.9 AMPERES 123.9 ROOFTOP GFI @ HVAC EQUIP 20 1 0.18 SPARE 20 1 •• - - ..... •• ...2._._.• • :::::::::4:4::::::::::::::: ManufacturerlT e• ' Circuit Breaker Type: RECEPTACLES (1ST 10KVA): Remarks: RECEPTACLES OVER 10KVA: LIGHTING: EQUIPMENT :.... -. HEATING: KITCHEN: 25% OF LARGEST MOTOR: CONNECTED: CONNECTED: 1.8 3.3 77 19.9 kVA kVA kVA kVA kVA kVA kVA. kVA GPs 100% 1.8 kVA 50% kVA 125% 4.1 kVA 100% 7.7 kVA 100% kVA 65% 13.0 kVA 25% kVA A 0.7 ❖. :• • VA4.;• : ❖:❖ • . : :❖P :•;•; ?; % ❖: ❖:•: Manufac Circuit Breaker Remarks • = PROVIDE urer/T e• Type: RECEPTACLES (1ST 10KVA): : -. RECEPTACLES OVER 10KVA: BREAKER HANDLE LOCKOFF 1 LIGHTING: EQUIPMENT. 1 HEATING: I KITCHEN: 25% OF LARGEST MOTOR: CONNECTED: � ` CONNECTED :" 13 3.3 43.7 40.4 19.9 kVA kVA kVA kVA kVA. kVA kVA kVA AmPs 100% 13 kVA 50% kVA 125% 4.1 kVA 100% 43.7: kVA 100% 40.4 kVA 65% 13.0 kVA 25% kVA A 0.7 03 15.1 13.5 5.5 B 07 1.9 14.3 13.5 72 C 0.4 0.8 14.3 13.5 72 4iii':J.4...i0•.iO.i00•i:•:Oiii• :i :•J ... ❖ :1 ❖ ::':`�:` ......A :•:00•ii ........................ :viii :iiii •iii•.i ❖i • T 1.8 3.3 43.7 40.4 19.9 O TOTAL CONNECTED LAD PER PHASE: 109.0 131.3 SERVICE DEMAND: 102.9 kVA DEMAND: 123.9 Amperes LOAD CALCULATIONS PHASE A: 35.4 kVA PHASE B: 37.5 kVA PHASE C: 36.1 kVA EXISTING SERVICE INFORMATION PROVIDED TO ABOSSEIN ENGINEERING - - BY OTHERS. VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO WORK -CO M • RG . DISCREPANCY EXISTS. 0 PANELBOARD LOCATION: BACKROOM - PANEL P LOAD DISTRIBUTION FEED FROM: PANEL H VIA45K XFMR FEEDER: 150 AMP 3P4W + GND PH REC LTG EQP HTG KIT CKT DESCRIPTION PH AMP POLE LOAD kVA AMP: 225 VOLTS: 208/120 PHASE: 3 WIRE: 4 BUS TYPE: CU A.I.C.: 10K M.L.O.: MAIN CB: 150 FLUSH: SURFACE: XXX GND. BAR: XXX ISO GND: 200% NEU: FEED THRU: DBL LUG: TOP FEED: BTM FEED: A B C A B C A B C A B C A 8 C A B C A B C 1.56 1 3. 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 ' 37 39 41 WALK IN FREEZER COMPRESSOR A B C A B C A B C A B C A B C A B C A B C 20 2 1.56 1.56 - - - 1.56 1.56 WALK IN COOLER COMPRESSOR 20 2 1.56 1.56 - - - 1.56 1.20 WALK IN LIGHTS/DEFROST 20 1 1.20 SPARE 20 1 SPARE ' 20 1 0.60 LIGHTING - DINING TRACK VIA CURRENT LIMITER 20 1 0.60 0.60 LIGHTING - FRONT OF HOUSE CANS, PENDANTS 20 1 0.60 0.60 LIGHTING - BACK OF HOUSE, BATHROOMS 20 1 0.60 075 POWER - EXTERIOR SIGNAGE 20 1 0.75 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE, 20 1 SPARE 20 1 SPARE 20 ` 1 SPARE 20 1 2.28 HOOD EXHAUST /MAKE UP AIR FANS 30 3 2.28 2.28 - - 2.28 2.28 2.28 . A..... B C A B C A B C A B C A B C A B C A B C .••• 0. 36•__._._._..._ ..•......••.•... ....e..._•..._e..•._....e._._.2 •• ..•..•....•••••.•.• ...RECEPTACLES 4 6 8 10 12 14 16 18 20 22 24 26 ' 28 30 32 34 36 38 40 42 .....•....••.•••...•....•••...• .._._......_..._A •••••.... • B C A B C A B C A 8 C A B C A B C A 8 C ,•...•.•, 20GFI..._;._._._..._ •..••..•.•••••••...t....••••. 0. 36-.._._. ..e.....e.............._..._... • P.O.S. SYSTEM......... 1.10 REFRIGERATED PREP TABLE 20GFI 1 1.10 1.80 GLASS WASHER (PROVIDE LOCKOFF) 20 1 1.80 0.36 GCO'S - ISLAND 20GFI 1 0.36 1.02 BACK BAR COOLER 20GF1 1 1.02 1.02 BACK BAR COOLER 20GF1 1 1.02 1.02 BEER SYSTEM 20GFI 1 1.02 0.92 REFRIGERATED PREP TABLE 20GFI 1 0.92 0.36 GCO'S - BACKBAR AREA 20GF1 1 0.36 FEEDER T.C.L. LOAD (kVA) SPARE 20GFI 1 0.54 RECEPTACLES - BATHROOMS, CORRIDOR 20 1 0.54 1.20 REFRIGERATED PREP TABLE 20GFI 1 : 1.20 REC 1.8 LTG 3.3 EQP 7.7 HTG KIT 19.9 1.40 REACH IN REFRIGERATOR 20GFI 1 1.40 1.36 DISHWASHER (PROVIDE LOCKOFF) " 20 1 1.36 1.65 ICE MACHINE (PROVIDE LOCKOFF) 20 1 1.65 0.40 ANSUL SYSTEM/GAS VALVE POWER 20 1 0.40 0.50 EXHAUST HOOD LIGHTING 20 1 0.50 TOTAL 32.7 0.20 EXHAUST HOOD CONTROL CIRCUIT 20 1 0.20 FEEDER DEMAND kVA - 26.5 AMPERES 73.6 0.45 DISHWASHER HOOD FAN 20 1 0.45 0.18 ROOFTOP GFI @ HVAC EQUIP 20 1 0.18 SPARE 20 1 •• - - ..... •• ...2._._.• • :::::::::4:4::::::::::::::: ManufacturerlT e• ' Circuit Breaker Type: RECEPTACLES (1ST 10KVA): Remarks: RECEPTACLES OVER 10KVA: LIGHTING: EQUIPMENT :.... -. HEATING: KITCHEN: 25% OF LARGEST MOTOR: CONNECTED: CONNECTED: 1.8 3.3 77 19.9 kVA kVA kVA kVA kVA kVA kVA. kVA GPs 100% 1.8 kVA 50% kVA 125% 4.1 kVA 100% 7.7 kVA 100% kVA 65% 13.0 kVA 25% kVA A 0.7 0.6 3.1 5.5 B 07 1.9 2.3 72 C 0.4 0.8 23 72 :• ::•:: • ::' :4 : : iii • •• „y••.•••••y••••.-•••••••••... •T• : :;:•5::.: . : ❖ :' : • :: :::•i ' •...7.7 :K: :0' : �' :• ; : ; :• :i:• :i: 1.8 3.3 19.9 TOTAL CONNECTED LOAD PER PHASE: 327 90.8 DEMAND: 26.5 kVA DEMAND: 73.6 Amperes PHASE A: 10.0 kVA PHASE B: 120 kVA PHASE C: 10.7 kVA 1 #6 CU EXISTING 2000A 480Y/277V 3P4W SERV CE - 29,809 AIC AT BUSS PER RECORD DWGS FAULT CURRENT CALCULATION TAG. SEE 'FAULT CURRENT CALCULATION' WITH RESPECTIVE TAG NUMBER ON THIS SHEET TYPICAL OF ALL AIC TAGS. CONTRACTOR- IS TO BRING UP ANY DISCREPANCIES - AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR - OR . SHOWN, BUT ARE REQUIRED FOR A COMPLETE ELECTRICAL - SYSTEM, AND WHICH AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT. AFTER AWARDING THE CONTRACT, ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY, FOR THE - OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH AFOREMENTIONED DISCREPANCY ITEMS AT NO ADDITIONAL COST TO THE OWNER. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO DETERMINE THE EXACT IMPACT OF THE RETROFIT TO THE ELECTRICAL SYSTEM AND SHALL INCLUDE IN HIS B ID ALL THE WORK WHICH MIGHT NOT BE SPECIFICALLY MENTIONED BUT IS REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM READY FOR OWNER'S BENEFICIAL USE. ALL WORK SHALL CONFORM TO U.L., 2008 NEC.,' N.F.P.A., AND ALL OTHER CODES OF JURISDICTION WHICH ARE APPLICABLE TO THIS ELECTRICAL INSTALLATION. - SEE ALSO 'TENANT CRITERIA MANUAL ", FOR ADDITIONAL INFORMATION CONCERNING THE RESPONSIBILITIES OF THE ELECTRICAL CONTRACTOR. READ PRIOR TO BID. POWER RISER FLAG NOTES LANDLORD 480Y/277V DISTRIBUTION/TENANT METERING W/ 200A FUSES. NO CHANGE. COORDINATE WITH UTILITY FOR METER INSTALLATION (IF NECESSARY). ADVISE OWNER'S REP IN FIELD IF ANY DISCREPANCY EXISTS. PROVIDE BOLT -ON BRANCH BREAKERS FOR THE PANELBOARDS. BREAKERS PROVIDED SHALL BE SIZED AND NUMBERED AS SHOWN ON PANEL SCHEDULES ON THIS SHEET. BRANCH CIRCUITS SHALL BE CONNECTED TO BREAKERS AS SHOWN ON PANEL SCHEDULE(S). EXISTING 200A FEEDER CONSISTING OF (4) 250kCMIL AL THWN & (1) #3/0 EGC (MC CABLE) TO EXISTING FUSED DISCONNECT IN SPACE. REMOVE FROM DISCONNECT AND PROVIDE J -BOX ABOVE GRID CEILING. ROUTE EXISTING FEEDER TO NEW J -BOX LOCATION. PROVIDE NEW 200A FEEDER, CONSISTING OF (4) 250kCMIL AL THWN & (1) #3/O EGC (MC CABLE) FROM NEW J -BOX- LOCATION TO NEW PANELBOARD 'H'. PROVIDE SPLICES IN J -BOX. PROVIDE NEW 225A, -200A MAIN BREAKER, 480Y/277V, 3P4W, 30 SPACE PANELBOARD. CONFIGURE BRANCH CIRCUITS PER PANEL SCHEDULE. PROVIDE NEW 45kVA, 60Hz, 3 PHASE, 480- 208/120V TRANSFORMER. LOCATE PER PLANS. GROUND PER NEC. PROVIDE NEW 70A FEEDER, CONSISTING OF (1) 1 1/4" CONDUIT WITH (3) #4 CU THWN & (1) #8 CU THWN EGC. PROVIDE NEW 150A FEEDER, CONSISTING OF ' (1) 2" CONDUIT WITH (4) #1/0 CU THWN & - (1) #6 CU THWN EGC. PROVIDE NEW 225A, 150A MAIN BREAKER, 208Y/120V, 3P4W, 42 SPACE PANELBOARD. CONFIGURE BRANCH CIRCUITS PER PANEL SCHEDULE. - Crbi UL 01185 RECEIVED CITY OF TUKWILA AUG 1 0 2009 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL ELECTRICAL CIVIL LE ED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98 .004 PII. 425 462-9441 9441 FAX. 425 462-9451 E -Mall c . service@ b ' a ossem,com www.abossein.com EXPIRES 8/1 0/10 PROJECT NAME CAFE PHO 633 Southcenter Mall S� pace -A 98188 8 TukwilaFC , W ISSUED FOR PERMIT ONLY NOT FOR BID OR CONSTRUCTION DRAWING TITLE RISER DIAGRAMS PANEL SCHEDULES JOB NUMBER 29047 DRAWN BY GN CHECKED BY AVA 7 -17 -09 LANDLORD REVIEW SET 7 -27 -09 PERMIT SET ISSUED DATE DESCRIPTION E04 OF 5 SECTION 16000 ELECTRICAL SPECIFICATIONS GENERAL 1. GENERAL CONDITIONS: A. The General Conditions, Supplementary Conditions and Special Conditions are a part of this contract and apply to this section as fully as if repeated herein. 2. SCOPE: A. This section of specifications includes, but is not limited to: All labor, tools, appliances, materials and equipment required to furnish and install the complete installation shown on the drawings for this section of the work and/or in the following specifications, including that which is reasonably inferred. 3. CODES AND REGULATIONS: A. All work and materials shall be in accordance with applicable requirements of public authorities having jurisdiction and utilities furnishing services. B Codes governing this work include but are not limited to the latest approved edition of the following: National Fire Protection Association's National Electrical Code (NEC). Occupational Safety and Health Act (OSHA)." Local Ordinances and Regulations. 4. STANDARDS: A. Electrical material and equipment shall have been tested and listed or labeled as conforming to approved published standards by Underwriters Laboratories where such listing or labeling service is available for the class of materials or equipment. Where applicable, listing or labeling shall apply to the complete assembled equipment and not to the components alone. 5. SUBMITTALS: A. Three copies of materials list, shop drawings and data sheets shall be submitted to Architect & /or Construction Manager for review. Submittals shall be made and favorable review secured before material and equipment is installed. B Materials list shall include fixtures, switchgear, panels, devices, , g , P v es, wireways, disconnects, lamps and all other specified or unspecified standard cataloged materials to be used The list shall include manufacturer, type and such other descriptive data as may be required to determine the acceptability of each item. C' Shop drawings and data sheets for ,equipment and systems shall be submitted where required in the specification for those items. Include information on each component, wiring diagrams, layouts, dimensions and sufficient other data to establish compliance with the specifications and acceptability of the equipment or system. 6. PERMITS AND DRAWINGS: A. Permits and inspections shall be by the General Contractor. 7. AS -BUILT DRAWINGS: A. On a set of contract drawings, kept at the site during construction, mark all work that is installed differently from that shown, including any revised circuitry, material or equipment U on conclusion of work , deliver to Owner's Rep. Construction Manager a set of signed and dated "as- built" drawings. 8. GUARANTEE: A. All work shall be guaranteed for a minimum period of one year from the date of acceptance by the Owner: The guarantee eriod for certain items shall be longer, P 9 er, as indicated in the specification for those items. B Should any malfunction develop during the guarantee time period due to defective material, faulty workmanship, or non- compliance with plans, specifications, codes or directions of the Owner, Architect, Engineer or Inspector, the Contractor shall furnish all necessary labor and materials to correct the malfunction with- out additional charges. PRODUCTS 1. DRY TYPE TRANSFORMERS: A Dry Type transformers shall be convection air cooled insulated winding type, constructed so that all applicable standards are met or exceeded (i.e. vent openings, corrosion resistance, cable bending space, ground provisions, sound levels and surface and temperature rise).. Acceptable manufacturers will be Square D, Siemens, General Electric, Cutler Hammer or approved equal. PP q al. B Transformers shall be provided with (6) 2 1/2 (four s four FCBN and two FCAN), Class H insulation for 115C degree C. temp rise, ventilated sheet metal enclosure, mounting rails and rubber vibration isolator between core and coil. : Coils shall be insulated with thermosetting varnish in accordance with NEMA ST20 standards for 200 degree C. insulation system as recognized by Underwriter's Labotatories. Transformer shall be wound for 480 volt, 3 phase, 3 wire delta primary and 208/120 volt, 3 phase, 4 wire wye secondary. Transformer shall be designed for operation at 60 Hertz and sound levels shall not exceed 60 decibels. 2. DIMMERS: Dimmer switches shall be complete with finned heat sink completely hidden behind an ABS plastic : front late. Color to match other devices - P P see sections 7, 8. Do not remove fins or derate the dimmer in any way. B `Dimmers shall be self contained solid state type in wattages as follows:: Up to 600W circuit load 600W dimmer Up to 1000W circuit load - 1000W dimmer Up to 1500W circuit load 1500W dimmer 3. PANELBOARDS: A. Panelboards shall be factory assembled circuit breaker type. The number of poles, t YP e , voltage and ampere ratings shall be as indicated on the drawings. Bussing shall be aluminum or copper schedules PP ( see panel )• Neutral wires. shall be B connected to a common neutral bus with binding screws or lugs. The neutral bus shall be insulated from the cabinet. Ground wires shall be connected to `a common equipment p round bus with binding screws or lugs. The ground bus ground 9 9 ground be bonded to the cabinet. Cabinets shall be flush or surface mounted (refer to panel schedules). Cabinets shall be constructe d o f 9 alvanized steel conforming to UL t 9 and NEC standards. Fronts of cabinets shall be not less than 12 gauge steel fastened with screws in countersunk washers, or with approved concealed spring clamps. Cabinet fronts shall have hinged lockable doors with milled keys (all panels shall be keyed alike) and circuit schedule holders with clear plastic windows. Provide typewritten schedules in holders and submit copies for record purposes. Doors shall be fastened to trim with full length flush hinges. Panel fronts shall be shop painted with 2 coats of primer and a finish coat of gray enamel. . Check load balance of panelboard under normal operation. If load imbalance exceeds 10% between phases, initiate corrective measures. AII conductor terminals and equipment enclosures shall be U.L. listed for use with minimum 75' C. rated conductors: G. Panelboard directory for each panel shall be neatly typed indicating.` actural load for each branch circuit. . Provide signage for all panelboards & switchboards warning qualified persons of potential flash hazard as required in N.E.C. 110 4. CIRCUIT BREAKERS: A. Circuit breakers shall be by the same manufacturer that furnishes the main service equipment and panelboards. B Breakers shall be molded case bolt -on Clamp-on, type . Clam _ _ P push on, "or plug-in types are not acceptable Removable handle ties and dual, quad or tandem breakers are not acceptable. Mounting hardware, accessories, faceplates and enclosures shall be provided as necessary for the intended use C. Short circuit interrupting capacity shall be as indicated on the plans and shall in no case be less than 10,000 rms symmetrical amps at the applied voltage. 5. DISCONNECT SWITCHES: A. Switches shall be by Square-D, Cutler Hammer, or equivalent. valent. B Switches and enclosures shall be ' general duty. They shall be externally operated, quick -make, blade type, of numbers of poles and rating indicated or required. C. Enclosures shall be NEMA I for dry, interior locations and NEMA 3R for damp, wet or exterior locations. Finish shall be ANSI 61. , Covers shall have a defeatable interlock. Operating handles shall be padlockable. Short circuit withstand ratings shall be 200,000 rms symmetrical amps. Switches shall accept fuses of the rating and UL or NEMA class indicated. Submit data sheets of the disconnect switches as required under "Submittals ". . AII conductor terminals and equipment enclosures shall be U.L. listed for use with minimum 75' C. rated conductors. 6. MANUAL MOTOR STARTERS: A. Where shown on the plans, fractional horsepower motors shall toggle type manual starters with thermal overload protection in each phase. Where the motor is out of sight of the switch provide a pilot light in the cover to indicate switch is closed. Submit data on starters as required under "Submittals ". 7. SNAP SWITCHES: A. AC general use snap switches shall be toggle handle, q uiet operating, premium or heavy duty specification grade, UL listed and verified to meet Federal Specification W -S- 896 -d and NEMA heavy duty tests. Color shall be Ivory. C. All switches shall be rated 120 /277 volts. - For the 20 amp size, HP ratings shall be 1 for 120V and 2 for 240V.' Switches shall be as listed below: 20A SPST - Hubbell 1221, Leviton 1221 or P & S 521 Switches required but not listed shall have equivalent quality as those listed above. 8. RECEPTACLE OUTLETS: A. Receptacle outlets shall be standard NEMA configuration, grounding type. B General convenience outlets shall be 20 am p, 125 volt, 2 , pole, 3 wire grounding. Outlets shall be UL listed and verified to meet . Federal Specification W -C- 596 -c and NEMA heavy duty performance tests. C. Convenience outlet fronts shall be Ivory. Color shall be brown on stained wood paneled walls. Confirm color with architect. An additional 20% of circuit load to be added for magnetic LV transformer use. 8. RECEPTACLE OUTLETS (cont): C. Outlets shall be as listed below: (numbers do not include color designation or options). 9 P ) D 20A Convenience Hubbell 5352, Leviton 5362, or P & S 5362 E Special outlets, not listed above, shall be standard NEMA configuration for the application shown and shall be of equivalent grade and quality to those listed above. An approved cord cap or plug shall be furnished with each receptacle outlet except general convenience type. Plug shall be of the same grade, quality and manufacturer as the outlet. 9. DEVICE & BOX COVER PLATES: A. Provide a plate for each outlet, receptacle, switch, device and box. 6, Plates for flush interior general use shall be Ivory plastic. Color shall be brown on stained wood paneled walls. Confirm plate colors with architect prior to ordering. C. AII plates for exterior use shall be listed and labeled "Suitable for Wet Location while in Use ". Ganged devices shall have gang plates exactly matching the arrangement and quantity of devices. Special plates, engraving or application shall be as indicated on the drawings or otherwise specified. 10. OUTLET AND JUNCTION BOXES: A. The size of each outlet or junction box shall be determined by the number and sizes of wires and conduits entering the box, per NEC, but shall be not Tess than 4 -inch square and 1-1/2 inches deep unless otherwise noted. C. Outlet and junction boxes for interior use shall be galvanized, one- piece pressed or welded steel, knockout type, except where other types of boxes are indicated or specified. In masonry or concrete construction waterproof boxes manufactured for that purpose shall be used. Plastic, fiber or composition boxes will not be permitted. Outlet and junction boxes for surface exterior use shall be cast boxes, Crouse -Hinds FS type, or approved equivalent. 11. CONDUITS AND FITTINGS: A. Standard weight rigid metal conduit shall be hot dipped galvanized, AII fittings shall be of the screw thread type Couplings, locknuts, bushings, etc., shall be hot dipped galvanized: B Electrical metallic tubing (EMT) shall be galvanized. Couplings and connectors shall be galvanized. Fittings shall be compression type with gland sealing rings or set screw type. C. Flexible conduit shall be galvanized steel or aluminum. Where used in damp or wet locations flexible conduit shall be of the liquid -tight type with outer neoprene jacket and suitable s. liquid-tight fittin 9 Rigid non - metallic conduit shall be PVC Schedule 40, U.L. approved. All couplings, fittings, solvent cement, etc.. 12. WIRE AND CABLE: A. ' Wire and cable for use on systems of 50 volts to 600 volts shall be 600 volt rated type THW or THHN for branch circuits. Feeders shall be THHN or THWN (see riser). B Wire and cable for use on systems of below 50 volts shall be 300 volt PVC insulated and suitable for the class of wiring except as otherwise indicated or specified. C. All conductors shall be Copper, rated 75'C minimum. D All wiring to be color coded as follows: 208/120V Phase A - Black Phase B - Red Phase C Blue Neutral -,- White 480/277V Phase A - Brown Phase B - Orange Phase C Yellow Neutral - White /tracer or Grey 13. LIGHTING FIXTURES AND LAMPS: A. Fixtures shall be complete with all required accessories and P q equipment, including lamps, necessary for a complete installation. Contractor shall receive, unpack, assemble and install fixtures indicated as being furnished by others. B Fluorescent ballasts shall be CBM /ETL certified, high frequency electronic type with a THD of less than 20 %. Fixtures shall comply with local lighting codes. PY 9 9 C. 4' fluorescent lamps shall be F32T8 type by Phillips, GE or Sylvania, color as indicated on plans. All A-type lamps shall be 130 volt. Verify the ceiling or wall construction,` voltage and the mounting requirements of each fixture and provide plaster frames, special flanges, concrete pour housings, boxes, brackets,: adapters, hangers, stems, canopys, special ballasts or lenses and other materials necessary to properly purchase and mount the fixture. Submit shop drawings on all fixtures as required under Submittals ". "Shop Drawings" may be catalog data sheets if complete information including mounting hardware is shown and identified. Shop drawings shall include mounting details and show compatibility with the ceiling or other equipment. 14. NAMEPLATES AND LABELS: A. Nameplates shall be provided for circuit breakers in the main switchboard, switches, and to identify each panelboard and similar items which are furnished or installed under this section. B : Nameplates shall be engraved laminated plastic with characters P 9 P cut through the black top layer er to white lay er below. 9 P Y Y 15. PHOTO ELECTRIC SWITCHES: A. Photo electric switches and photo controllers shall be Honeywell, Tork or equivalent. Type of mounting, poles, voltage, wattage rating and arrangement shall be as shown on plans: B Submit shop drawings as required under "Submittals" Catalog sheets will be adequate if all information is shown. 16. TIME SWITCHES: A. Time switches shall be Intermatic or Tork. Type of mounting, poles, voltage, ampacity and arrangement shall be as shown on drawings or required by conditions. Time switches controlling lighting shall have battery backup and any other features shown on the P lans or required for proper operation. B Enclosures shall be NEMA I for interior dry locations. 17. MAGNETIC MOTOR STARTERS: A. Motor starters shall be horsepower rated non - reversing, full voltage of type required by motor with overload thermal protection. Submit shop drawings as required under "Submittals ". 18. RELAYS: A. Relays for motor control shall be heavy -duty industrial type, magnetically held, with both normally open and closed contacts: B. Submit shop drawings as required under "Submittals ".` EXECUTION 1. INSTALLATION AND CONNECTION OF ELECTRICAL EQUIPMENT: A. Equipment furnished by others shall be completely connected to the electrical system except as noted on the drawings: All fuses, breakers and disconnects shall be provided as necessary for proper protection. Provide all flexible conduit, boxes, fittings, receptacles, cords, plugs and other material required for proper installation. Refer to manufacturer's directions where applicable. 2. WORK ON HVAC AND PLUMBING SYSTEMS: A. power Complete circuits, including breakers, switches, P P 9 disconnects, wire and conduit, outlets and connections to HVAC and plumbing equipment shall be provided under this section. B Starters and controllers shall be provided under this section except where part of a package unit or panel specified in Division 15. C. HVAC and plumbing control and interlock wiring regardless of voltage, and conduits for same, will be wired and connected under this section. 3. INSTALLATION OF CONDUIT: A. Standard weight rigid metal conduit shall be used where exposed to the weather, placed underground below concrete slab, in concrete or masonry construction in contact with earth, and where shown on the plans. 8 Galvanized steel electrical metallic tubing shall be used in above ground, interior, dry locations protected from weather and physical damage, and may be used in concrete or masonry construction not in contact with earth. C. Flexible Metallic conduit shall be used where shown on the plans and to connect conduit systems to motors, direct wired and vibrating equipment and as a final connection to lighting fixtures (6' max) in accessible ceilings. It may be used as a wiring system instead of EMT in interior walls only (dry frame or stud construction), when Y( Y ), allowed by Landlord and /or Owner: DLi uidti ht flexible metal conduit shall be used for final electrical q 9 connections to roof top or other equipment ex osed to the P exposed Rigid non- metallic conduit may be used for all underslab or underground work in place of standard weight rigid metal and where specifically specified. AII runs of rigid non-metallic conduit shall contain a separate green ground wire adequately sized for service intended. Where required to continue above slab, stub non- metallic conduit 6" above slab then make ro er transition P P to metal .conduit. AII rigid steel conduit • installed in the ground shall be wrapped with Hunt's Process No. 3, PVC coated or encased in 3" PP , concrete on all sides: G. The minimum sizes of conduit shall be code size for the number and size of conductors, unless a larger size is shown, in which case such larger size shall be used All final connections to motors shall be flexible metal conduit and as shown on drawings. Where portions of raceways or sleeves enter areas such as cold storage or where passing from the interior to the exterior of `a building, the raceway or sleeve shall be filled with an approved material to prevent the circulation of warm air to a cooler section of the raceway or sleeve. 4. INSTALLATION AND CONNECTION OF WIRING: A. No Type AC or NM (Romex) cable will be permitted on this project. AII ` wiring shall be installed in conduit, except where other raceway systems or methods are specifically shown. Ys P Y B. Clean out and dry all conduit and wireways before pulling any Y Ys P 9 wires. Use no lubricant except as recommended by the wire or cable manufacturer. C. Make all connections and splices necessary to properly complete the electrical wiring. Connections and splices shall be made only in pull, junction or outlet boxes, or in switchboards, wireways or panels having sufficient code sized gutter space. Connections and splices in wires smaller than No 6 AWG shall be made with spring type connectors, and in wires No 6 AWG and larger shall be made with compression, vise type, or split bolt solderless connectors, insulated and toed. P P 5. TELEPHONE SYSTEM: A. Furnish and install complete conduit and terminal system for telephone services as indicated on drawings: B Install a 1/8 -inch polyethylene pull -in wire in each conduit run: C. Telephone wall outlets shall be 4 -11/16 inch square by 2 -1/8 inch deep metal boxes, with plaster ring and single bushed outlet flush telephone plate. D Furnish and install 3/4 -inch conduit from the telephone equipment room main telephone backboard to nearest accessible building ground. Th'ts' conduit should be terminated in such a manner that access to grounding device may be had at any time in the future. * -Per NEC 250 & NEC 800 6. GROUNDING: A. Make good mechanical and electrical contact at all poles, panelboards, switchboards, outlet boxes, junction boxes, and wherever the conduit run is connected. Permanently and effectively ground all conduit, fixtures, motors and other equipment as required by all applicable codes, regulations and standards. NEC 250 7. CLEANING AND PROTECTION OF PRODUCTS AND PREMISES: A. At frequent intervals during the time of construction, the Contractor shall clean up after his work and remove his debris from the premises, leaving the building and grounds clean to the Owner's satisfaction. The Contractor shall take all necessary precautions to protect all materials, equipment and property, whether electrical or not, from damage as a result of his work. 8. CHECKING AND TESTING OF EQUIPMENT AND SYSTEMS: A. Panels, disconnects, starters and other equipment installed under this section shall be inspected for defects and tested for proper operation. B. Systems shall be tested for short circuits, , o en circuits open wrong connections and shall be free from mechanical and electrical defects. Circuits shall be tested for proper neutral and ground connections.' 9. TEMPORARY CONSTRUCTION POWER & TELEPHONE: A. Electrical Contractor shall provide all labor, cost and materials required for installation and maintenance of temporary construction power and telephone. Construction power shall be minimum of 100A, 120/208V /1 phase, 4W, with provisions for one 50A, 208V, 2P, 4W grounding receptacle and four 120V, 20A, 1P receptacles. 10. SUBSTITUTIONS: A. Alternative manufacturers will be considered for electrical devices, switches, outlets, etc. not provided by owner. B. Catalogs, data sheets or shop drawings shall be submitted to the construction manager for all alternative manufactured equipment as required under "Submittals ". E ()I-185w RECEIVED CITY OF TUKVVILA AUG 10 Z009 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL ELECTRICAL CIVIL LEED FIRE PROTECTION 2100 112TH AVE. NE ,LE BE1 VUE WA 98004 PH, (425 ) 462 -9441 l FAX: (425 ) 462-9451 E-Mail: cservice @abossein,com www.abossein.com EXPIRES 8/1 0/10 PROJECT NAME CAFE PHO 633 Southcenter Mall S Tukwil a WA WA 981 88 ISSUED FOR PERMIT ONLY NOT FOR BID OR CONSTRUCTION DRAWING TITLE AL ELE TRI C C SPECIFICATIONS JOB NUMBER: 29047 DRAWN BY GN CHECKED BY AVA 7 -17 -09 LANDLORD REVIEW SET 7 -27 -09 PERMIT SET ISSUED DATE DESCRIPTION E SPEC (OF 5)