Loading...
HomeMy WebLinkAboutPermit EL09-0558 - ASHLEY FURNITUREASHLE FURNITURE 17601 SOUTHCENTER PY ELO9-0558 Catyllif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3523049087 Address: 17601 SOUTHCENTER PY TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL09 -0558 Issue Date: 09/04/2009 Permit Expires On: 03/03/2010 Tenant: Name: ASHLEY FURNITURE Address: 17601 SOUTHCENTER PY , TUKWILA WA Owner: Name: LEVITZ TUKWILA LLC Phone: Address: C/O ACADIA DR MANAGEMENT INC , 1311 MAMARONECK AVE STE 260 Contact Person: Name: BRAD SHUPE Address: 4826 B ST NW SUITE 101 , AUBURN WA Contractor: Name: KIRBY ELECTRIC INC Address: 4826 B ST NW, STE 101 , AUBURN WA Contractor License No: KIRBYEI077BN Phone: 253 - 859 -2000 Phone: 253 859 -2000 Expiration Date: 01/13/2011 DESCRIPTION OF WORK: LIGHTING RETROFIT. DEMO EXISTING HIGH- BAY /STRIP LIGHTS AND INSTALL NEW FLOURESCENT ENERGY EFFICIENT HIGH -BAY. SOME OF THE LIGHTING WILL BE EQUIPPED WITH OCCUPANCY SENSOR FOR MORE EFFICIENCY Value of Electrical: NRES: $50,000.00 Fees Collected: $1,135.00 RES: $0.00 Type of Fire Protection: UNKNOWN National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: I hereby certify that I have read and ec ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied th whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erformance ork. I am authorized to sign and obtain this electrical permit. Signature: ` — Date: Print Name: oJ. �alr' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0558 Printed: 09 -04 -2009 Parcel No.: 3523049087 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17601 SOUTHCENTER PY TUKW ASHLEY FURNITURE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL09 -0558 ISSUED 09/01/2009 09/04/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: 51/2-7 607- Date: V °� doc: Cond-Elec EL09 -0558 Printed: 09 -04 -2009 S CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 17601 Southcenter Pkwy Tenant Name: Ashley Furniture King Co Assessor's Tax No.: 3S )- 3011 " 90 8 7 Suite Number: Floor: New Tenant: Property Owners Name: Levitz Tukwila LLC. ❑ Yes ..No Mailing Address: 1311 Mamaroneck Ave., Ste. 260 White Plains NY 10605 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Brad Shupe Day Telephone: (253) 859 -2000 Mailing Address: 4826 B St. NW, Ste. 101 Auburn WA 98001 E -Mail Address: brad @kirbyelectric.com City Fax Number: State (253) 859 -2363 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Kirby Electric Inc. Mailing Address: 4826 B St. NW, Ste. 101 Auburn WA 98001 Contact Person: Brad Shupe E -Mail Address: brad @kirbyelectric.com Contractor Registration Number: KIRBYE1077BN City Day Telephone: Fax Number: Expiration Date: State (253) 859 -2000 (253) 859 -2363 01/13/2011 Zip Valuation of Project (contractor's bid price): $ 50,000 Scope of Work (please provide detailed information): Lighting retrofit. Demo existing high- bay /strip lights and install new fluorescent energy efficient high -bay. Some of the lighting will be equipped with occupancy sensor for more efficiencn Will service be altered? ❑ Yes ® No Adding more than 50 amps? ❑ Yes ® No Type of Use: Commercial warehouse. Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light ❑ Service Change ❑ Fire Alarm n \Apphcauons'Forms- Apphcaaons on Line \I -2009 - Flectncal Permit Application doc bh ® Remodel ❑ Telecommunication ❑ Tenant Improvement ❑ Temporary Service Page I of 2 • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $145.60 (including an attached garage) ❑ Garages. pools. spas and outbuildings $78.00 ea ❑ Low voltage systems (alarm. furnace thermostat) $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANCES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65:00 ❑ Low voltage systems $57.00 (alarm. furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall he requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED TIIIS APPLICATION AND KNOW 'HIE SAME TO BE TRUE UNDER PENALTY OF P .' URY BY TI lE LAWS OF THE STATE OF WASHINGTON, AND I AM AUI'I IORIZED TO APPI.Y FOR TI IIS PERMIT. BUILDING O ' N R,OR ELEC NT 'i OR: Signature: Print Name: oug K t,y Mailing Address: 482 B St. NW, Ste. 101 Date: 09/01/2009 Day Telephone: (253) 859 -2000 Auburn, WA 98001 City. State Zip IDate Application Accepted: 9-1-0/ Date Application Expires: Staff Initials: H \Apphcations\Form .Applications On I.ine'I -2009 - Electrical Permit Application doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049087 Permit Number: EL09 -0558 Address: 17601 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 09/01/2009 Applicant: ASHLEY FURNITURE Issue Date: Receipt No.: R09 -01377 Payment Amount: $1,135.00 Initials: WER Payment Date: 09/01/2009 04:07 PM User ID: 1655 Balance: $0.00 Payee: KIRBY ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 510029 1,135.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 908.00 000.345.832.00.0 227.00 Total: $1,135.00 PAYMENT RECEV ED doc: Receiot -06 Printed: 09 -01 -2009 INSPECTION RECORD Retain a copy with permit (f INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3610 Project: 4JI J �+CO* (1'[LDate of Inspection: 2/ D� Address: /160/ C Called: Special Instructions: Date Wanted: lD/oI 6.1r7 . , Requester: Phone No: I X I Approved per applicable codes. Ej Corrections required prior to approval. COMMENTS: 0.K. c,i4e6tibost litqfnAlt‘ (A141,- Inspector: ` _ l l+1 1�/ A/ Date: /oiooro7 $60.00 REINSiiECTION FEE REQUIRED. Prior to inspec ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Ashley Furniture Date 9/1/2009 17601 Southcenter PKWY For Building Department Use FILE COPY Tukwila, WA 98188 Applicant Name: Kirby Electric Applicant Address: 4826 B St. NW, Ste. 101, Auburn, WA 98001 Applicant Phone: 253 - 859 -2000 Project Description 133065.0 ❑ Plans Included requirements. ❑ New Building ❑ Addition ' Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area Warehouse F -bay light fixture Retail /palet rack shelving 1.50 88710.0 133065.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 133065.0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Warehous F -bay light fixture 210 285.0 59850.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 59850.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if tang, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. ixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and d in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual rack lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, iting devices or of the transformer. empt lighting, note section and exception number, and leave Watts /Fixture blank. REVI COMPL 1,411 tt°a Ig atts/ fi rrent I 3. List all fixtures. For e SEP 0 3 2009 City of Tukwila BUILDING DIVISION ELO'1 0558 RECEIVED SEP 01 2009 PERM] CENTEF 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lightin,g Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers O Other Q ualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector ) P ) or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Liphtinq Power Allowance (LPA Use' LPA` (W /sf) Use' LPAZ (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)53•" 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations5 1.0 Cafeterias, fast food establishments5, restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail70, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hall3•4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries5 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. PLAN REVIE /ROUTING SLIP ACTIVITY NUMBER: EL09 -0558 PROJECT NAME: ASHLEY FURNITURE SITE ADDRESS: 17601 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # DATE: 09 -01 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPARTNJENTS: Building Division Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator ii DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 09-03-09 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 10-01-09 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip doc 2 -28 -02 Untitled Page • r Page 1 of 2 Electrical Contractor A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name KIRBY ELECTRIC INC UBI No. 601433048 Phone 2538592000 Status ACTIVE Address 4826 B ST NW STE 101 License No. KIRBYEI077BN Suite /Apt. License Type ELECTRICAL CONTRACTOR City AUBURN Effective Date 1/15/1993 State WA Expiration Date 1/13/2011 Zip 98001 Suspend Date County KING Specialty 1 GENERAL Business Type Corporation Specialty 2 UNUSED Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status KIRBYE *101QE KIRBY ELECTRIC ELECTRICAL CONTRACTOR GENERAL UNUSED 11/5/1990 11/5/1994 ARCHIVED MASTER ELECTRICIAN INFORMATION License KIRBYDE962LZ Name KIRBY, DOUGLAS E Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date KIRBY, DOUGLAS E Cancel Date 01/01/1980 Bond Amount KIRBY, SHANNON 5 01/01/1980 70607132 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 WESTERN SURETY CO 70607132 01/14/2009 Until Cancelled $4,000.0011/05/2008 MERCHANTS https: // fortress .wa.gov /lni /bbip /Detail.aspx 09/04/2009 ASHLEY FURNITURE EMERGENCY EGRESS LIGHTING PLAN KIRBY RACK ELEVATIONS INTERNATIONAL STORAGE SYSTEMS