Loading...
HomeMy WebLinkAboutPermit EL09-0677 - SOFTLAYERSOFTIE YER 3355 S 120 PL ELO9-0677 Cityef Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL09 -0677 Issue Date: 11/09/2009 Permit Expires On: 05/08/2010 Tenant: Name: SOFTLAYER Address: 3355 , TUKWILA WA Owner: Name: SABEY CORPORATION Phone: Address: 12201 TUKVVILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: LAURA WINNOW Phone: 206 - 436 -5245 Address: PO BOX 80467 , SEATTLE WA Contractor: Name: VECA ELECTRIC CO INC Phone: 206 860 -0231 Address: 5614 7 AV S , SEATTLE WA Contractor License No: VECAECI542MU Expiration Date: 10/31/2011 DESCRIPTION OF WORK: INSTALLATION OF (6) 400 AMP 480 VOLT STATIC TRANSFER SWITCHES, (2) 300 KVA COMBINATION STATIC SWITCHE /POWER DISTRIBUTION UNITS, AND (12) 150 KVA POWER DISTRIBUTION UNITS. FOR (6) INDIVIDUAL SERVER POD UNITS. IN ADDITION (4) 50 HP 480 VOLY RELIEF FANS, GENERAL LIGHTING AND BRANCH POWER. Value of Electrical: NRES: $877,371.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: 2008 Date: $10,807.50 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the • erformannce of work. I . authorized to sign and obtain this electrical permit. Signature: L Date: / ! / q —69C Print Name: 4/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0677 Printed: 11 -09 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Tenant: SOFTLAYER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL09 -0677 ISSUED 10/29/2009 11/09/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature Print Name: Date: /(-7-- -- �r doc: Cond -Elec EL09 -0677 Printed: 11 -09 -2009 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httpl/wwvv.ci.tukwila.wa.us Electrical Permit No. FLD - 0 (Q 17 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: tW -?. -i— Site Address: 3355 S 120th PI Tenant Name: SOftlaver Property Owners Name: Sabey Corporation Mailing Address: 12201 Tukwila International Blvd Suite Number: Floor: New Tenant: El Yes El ..No Tukwila, WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Laura Rannow Mailing Address: PO Box 80467 E -Mail Address: Iaura.rannow @veca.com Day Telephone: 206- 436 -5245 Seattle, WA 98108 City State Fax Number: 206 - 763 -0505 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: VECA Electric Co. INC Mailing Address: 5614 7th Ave S Contact Person: Lloyd Tibeau E -Mail Address: Iloyd.tibeau@veca.com Contractor Registration Number: VECAECI542MU Seattle WA City State Day Telephone: 206 - 850 -8239 Fax Number: 206 - 763 -0505 Expiration Date: 10/31/11 98108 Zip Valuation of Project (contractor's bid price): $ 877,371 Scope of Work (please provide detailed information): Installation of (6) 400amp 480v Static Transfer Switches, (2) 300kva Combination Static Transfer Switch/ Power Distribution Units, and (12) 150kva Power Distribution Units. For (6) individual Server Pod Units. In addition (4) 50HP 480v Relief Fans. general lighting. and branch power. Will service be altered? Type of Use: Data Center Yes ❑ No Adding more than 50 amps? El Yes ❑ No Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy ® Seattle City Light ❑ Service Change ❑ Fire Alarm H Wpphcationstrorms- Apphcanons On Line \4-2007 - Electrical Permit Application.doc bh ❑ Remodel ® Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signa re: Print Name: Laura Rannow Mailing Address: 5614 7th Ave S Date Application Accepted: Date: 10/27/09 Day Telephone: 206- 436 -5245 Seattle HAApplicationsTotms- Applications On Line \4-2007 - Electrical Permit Applicahon.doe bh City Date Application Expires: H—'1 !,__ WA State Staff Initials: 98108 Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3355 S 120 PL TURIN Suite No: Applicant: SOFTLAYER RECEIPT Permit Number: EL09 -0677 Status: PENDING Applied Date: 10/29/2009 Issue Date: Receipt No.: R09 -01754 Payment Amount: $8,646.00 Initials: ]EM Payment Date: 11/06/2009 10:53 AM User ID: 1165 Balance: $0.00 Payee: VECA ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 050356 8,646.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 8,646.00 Total: $8,646.00 'AYMENT RECEIVED doc: Receipt -06 Printed: 11 -06 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Applicant: SOFTLAYER RECEIPT Permit Number: EL09 -0677 Status: PENDING Applied Date: 10/29/2009 Issue Date: Receipt No.: R09 -01701 Initials: User ID: Payee: WER 1655 Payment Amount: $2,161.50 Payment Date: 10/29/2009 09:38 AM Balance: $8,646.00 VECA ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 002635 ACCOUNT ITEM LIST: Description 2,161.50 Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 2,161.50 Total: $2,161.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 10 -29 -2009 INSPECTION NO. INSPECTION RECORD Retain a copy with permit £w7- 077 P MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: 2/049 Address: 33 c-5-.5 ` 20 FL. Date Called: Special Instructions: Date Wanted: 2.12y p.m. Requester: ti„.. cCA- 14 or di Phone No: X Approved per applicable codes. D Corrections required prior to approval. COMMENTS: -41,/ f� Date: 0212.1/1 ❑ $60.00 REINSP CTION FEE REQU RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit £ - c -77 P RMIT NO. (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 Project:r.Th r Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: 0/ a.m. p. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. CO MMENTS 5 PA( - litertlffibakt bpAs5 PA7.16- Inspector: Date: 02/01.1A 0 ri $60.00 REINSP CTION FEE RE • UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSP ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit aoTP RMIT NO. � (206)431 -3670 T(' Project: jor Type of Inspection: 00 Address 335� ao ft_ Date Called: Special Instructions: Date Wanted: 2 f 01 .m. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. S COMMENTS: • C6(1/14G\ El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit P'RMIT NO. CITY OF TUKWILA BUILDING DIVISION 12-1.— 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ek Type of Inspection: 7_ 003 Address: 3355.- 4 ,1 ..., D Date Called: ` Special Instructions: Date Wanted: , I� a.m. p.m. Requester: Phone No: 11 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: (JiDtib /60011Jcl rAtimmizo Date: O1 6- I ri $60.00 REINSP TION FEE REQUI ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6Lo -007 PE NO. CITY OF TUKWILA BUILDING DIVISION 12'- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: -ivei(vc Type of Inspection: 7004..._ Address:33 — /20 pt..... Date Called: — Special Instructions: Date Wanted: 4m. Requester: Phone No: DApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: P�- 0 .4 ///A PPc-<4 Inspector: -7 (' Date: O, /, 0 $60.00 REINS CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPE ION NO. INSPECTION RECORD Retain a copy with permit (Col- 0477 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: i� Type of Inspection: 70°3 Address: ` 335-3 c -5• / Pt. . Date Called: �„ Special Instructions: C't/ 04 A &k J Date Wanted: 11 I 0 a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: vk 01K. - covm 3 x pcoK_ vtsriut-f (pL-tJ4'J i4 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 500.0— HUE COPY Permit No. AMA SABEY D7802-01:dat 02/06/09 - 03/10/09 414 TIME DENT Instrument s ELOG 200S = Chan 11 Avg. Amp Avg 121.98,, Min 2157, Max 485 — Chan 2 Avg. Amp Avg 129.70, Min 32.33, Max 47103 Chan' 3 Avg. Amp Avg 129.116„ Min 3170; MaX,460t46 E th o MIMED FOR COMPLIANCE', WITH NFPA,70) - NEC NOV 5 2009 BUILDING DIVISION City otlibkwila, RECEIVED NOV 014 2009'i PERMIT CENTER 600.0-7 500.0— 300.0- 2oolo4) 10a0— FnLE COPY Perna, Noe AvinI66thti M52 B SABEY D7804-01.dat 02/06/09 - 03/10/09 0 TIME. 0 0 0) DENT' Instruments ') E LOG' 2006) - Chan 1 Avg', Amp Avg1161.62,,MiniaDa — Chan 2 Avg. Amp Avg 282.40, Min 0.80, Max 504.65 Chan 3 Avg.. Amp Avg 26869, Min D.Da Max4911.59' REVIEWED FOR COMPLIANCE, WITH NFPA -) NEC NOV 0 5 20.05 City OtTulkwild, _ BUILDING DIVISION] _ RECEIVE NOV 014 200g PERMIT CENT PERMIT CENTER VECA Electric SWBD HDP52A . ROOM: SDC 52 MAIN ELEC ROOM UNIT SUBSTATION TA -52 Phase A LOAD DISTRIBUTION FROM: RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 0.0 0.0 375.0 0.0 UPS 52-Al PRIMARY 1200 3 375 451 UPS 52 -A1 STATIC BYPASS 1200 3 - - AMP: 4000 MBP -52 -A1 MAINT BYPASS 1200 3 - - VOLTS: 277 0.0 0.0 375.0 0.0 UPS 52 -A2 PRIMARY 1200 3 375 451 480 UPS 52 -A2 STATIC BYPASS 1200 3 - - PHASE: 3 MBP -52 -A2 MAINT BYPASS 1200 3 - - WIRE: 3 0.0 0.0 375.0 0.0 UPS 52 -A3 PRIMARY 1200 3 375 451 BUS: CU UPS 52 -A3 STATIC BYPASS 1200 3 - A.I.C.: 65K MBP -52 -A3 MAINT BYPASS 1200 3 - - M.L.O.: UPS 52 -A4 PRIMARY (FUTURE) 800 3 - - MAIN CB: YES UPS 52 -A4 STATIC BYPASS (FUTURE) 800 3 - - FUSE: MBP -52 -A4 MAINT BYPASS (FUTURE) 800 3 - - FLUSH: 3.4 0.0 1250.5 0.0 M -52 -A MECHANICAL PANEL 3rd FLOOR 1600 3 1,254 1,508 SURF: YES 0.0 12.0 13.8 0.0 52A -H1 LIGHTING VIA 30 KVA 50 3 26 31 2.7 0.0 6.9 0.0 TRANSFORMER 52A -L1 50 3 10 12 TVSS 100 3 - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - TOP: - - BTM: YES FEE COPY PANEL T.C.L. °`7 - - -11P; 11111,. - - LOAD (kVA) - - RCPT 6 - - LTG 12 - - EQP 2,396 - - HEAT - - - TOTAL 2,414 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 6 - - LTG 12 - - EQP 2,396 - - HEAT - - - TOTAL 2,414 - - FEEDER DEMAND - - kVA 2,417 TOTAL 2,414 2,904 AMPS 2,908 6 1 12 2.3966Op - MFG: CB: :SQ D REVIEWED NF -A 0- E O °A9 ' —COMPLIANCEINITH C NOTE: 'SWITCHBOARD HAS DUAL INPUT BREAKERS WITH AUTOMATIC TRANSFER FROM NORMAL TO GENERATOR POWER. - -•- - - ---- 10/26 /0f '-----140V. - 5 2009 Project: SDC 52 Central Plant RECEIVED A q i'l i_ va7 `7 OCT 2 9 2009 City of Tukwila BUILDING DIVISION PERMIT CENTER VECA Electric SWBD M -52 -A _ Phase A ROOM: 3RD FLOOR MECHANICAL ROOM LOAD DISTRIBUTION FROM HDP -52A _ RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 17.5 AHU -52 -A3 UPS Room (Central Plant) 40 3 18 21 9.0 RF -52A UPS Room (Central Plant) 20 3 9 11 AMP: 1600 51.0 RF -5201A 2nd Floor (King County) 100 3 51 61 VOLTS: 277 51.0 RF -5203A 2nd Floor (Providence) 100 3 51 61 480 28.0 ACU- 5201 -1 2nd Floor (King County) 60 3 28 34 PHASE: 3 19.0 25% of the Largest Motor 19 23 WIRE: 3 64.0 AHU -52 -A1 3rd Floor (Central Plant) 125 3 64 77 BUS: CU 64.0 AHU -52 -A2 3rd Floor (Central Plant) 125 3 64 77 A.I.C.: 65K 3.4 0.0 0.0 0.0 TRANSFORMER 52A -L3 3rd Floor (Central Plant) 50 3 3 4 M.L.O.: YES 218.0 CH -52 -A1 Roof (Central Plant) 350 3 218 262 MAIN CB: 218.0 CH -52 -A1 Roof (Central Plant) 350 3 218 262 FUSE: 218.0 CH -52 -A2 Roof (Central Plant) 350 3 218 262 FLUSH: 218.0 CH -52 -A2 Roof (Central Plant) 350 3 218 262 SURF: YES 24.0 CHP -52B Roof (Central Plant) 40 3 24 29 3 - - 3 - - IG GND: 3 - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: 51.0 RF -5201 D 2nd Floor (King County) 100 3 51 61 BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT 3 - - LTG - - - EQP 1,251 - - HEAT - - - TOTAL 1,254 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 3 - - LTG - - - EQP 1,251 - - HEAT - - - TOTAL 1,254 - - FEEDER DEMAND - - kVA 1,254 TOTAL 1,254 1,508 AMPS 1,508 3 - 1,251 - MFG: :Square D . ... - - - - - -- - - CB: :Square D ; NOTE: Project: SDC 52 Central Plant 10/26/09 VECA Electric PANEL: .52A -H1 ___ _ _ _____ ROOM: PROVIDENCE OFFICE FEED.-THRU: _ LOADS FROM: HDP -52A _ A B 1 C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS , 2.0 1 PROVIDENCE DATA CENTER LIGHTS A 20 1 2.0 7.2 I 2.0 3 KING COUNTY DATA CENTER LIGHTS B 20 1 2.0 7.2 AMP: 100 2.0 5 PROVIDENCE OFFICE LIGHTS C 20 1 2.0 7.2 VOLTS: 277 2.0 7 GENERATOR ROOM LIGHTS A 20 1 2.0 7.2 480 2.0 1 9 UPS ROOM LIGHTS B 20 1 1 2.0 7.2 PH: 3 2.0 11 SOFTLAYER DATA CENTER LIGHTS C 20 1 2.0 7.2 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: 1 35 _ C 20 1 0.0 0.0 FD THRU: 37 A 20 1 0.0 0.0 DBL LUG. 39 B 20 1 0.0 0.0 TOP: 41 C 20 1 0.0 0.0 BTM: YES 3.0 2 SUMP PUMP 52A A 20 ' 3 3.0 10.8 PANEL T.C.L. 3.0 4 SUMP PUMP 52A B 3.0 10.8 LOAD (kVA) ' 3.0 6 SUMP PUMP 52A C " " 3.0 10.8 RCPT 0.0 0.8 8 EXHAUST FAN 52A -1 A 20 3 0.8 2.9 LTG 12.0 0.8 10 EXHAUST FAN 52A -1 B " " 0.8 2.9 EQP 13.8 0.8 12 EXHAUST FAN 52A -1 C " " 0.8 2.9 HEAT 0.0 0.8 14 EXHAUST FAN 52A -2 A 20 3 0.8 2.9 1 0.8 16 EXHAUST FAN 52A -2 B 0.8 2.9 TOTAL 25.8 0.8 18 EXHAUST FAN 52A -2 C 0.8 2.9 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. r 22 B 0.0 0.0 LOAD (kVA) 24 C " " 0.0 0.0 RCPT 0.0 26 A 30 3 0.0 0.0 LTG 12.0 28 B " " 0.0 0.0 EQP 13.8 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 25.8 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 28.8 42 C 20 1 0.0 0.0 AMPS 34.6 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 0.0 12.0 13.8 0.0 KVA/AMPS: 8.6 31.0 8.6 31.01 8.6 31.0 Mfg/Type: Square D 0.0 4.0 4.6 0.0 A CB Type: 0.0 4.0 4.6 0.0 B Remarks: - 0.0 4.0 4.6 0.0 C VECA Electric PANEL: 52A -L1 -THRU: ROOM: JSDC 52 GENERATOR ROOM FEED LOADS FROM: HDP 52A VIA XFMR 52A -L1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.5 1 GENERATOR A BLOCK HEATER A 20 2 1.5 12.5 1.5 3 GENERATOR A BLOCK HEATER B 1.5 12.5 AMP: 100 0.5 5 GENERATOR A BATTERY CHARGER C 20 1 0.5 4.2 VOLTS: 120 7 SPARE A 20 1 0.0 0.0 208 0.5 9 DAY TANK 52A CONTROLS B 20 1 0.5 4.2 PH: 3 0.5 11 HEAT TRACE C 20 1 0.5 4.2 WIRE: 4 1.0 13 AHU -52 -A3 MOTORS /ACUATORS A 20 1 1.0 8.3 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N. 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 1.1 0.0 0.6 0.0 2 PANEL 52A -L2 A 50 3 1.7 14.0 PANEL T.C.L. 1.2 0.0 0.4 0.0 4 PANEL 52A -L2 B 1.6 13.3 LOAD (kVA) 0.4 0.0 0.4 0.0 6 PANEL 52A -L2 C " " 0.8 6.7 RCPT 2.7 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 6.9 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 16 B 0.0 0.0 TOTAL 9.6 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 2.7 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 6.9 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 9.6 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 9.6 42 C 0.0 0.0 AMPS 26.6 - A 0.0 0.0 - B " 0.0 0.0 - C 0.0 0 -0 2.7 0.0 6.9 0.0 KVA/AMPS: 4.2 34.8 3.61 30.0 1.8 15.0 Mfg/Type: Square D 1.1 0.0 3.1 0.0 A CB Type: 1.2 0.0 2.4 0.0 B Remarks: - 0.4 0.0 1.4 0.0 C VECA Electric PANEL: 52A -L2 FEED -THRU: ROOM: 2ND FLOOR ELECTRICAL CLOSET LOADS FROM: PANEL 52A -L1 A B C RCPT LTG EQP J HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 0.8 1 ACCO BUILDING CONTROLS A 20 1 0.8 6.7 0.8 3 ACCO BUILDING CONTROLS B 20 1 0.8 6.7 AMP: 100 5 SPARE C 20 1 0.0 0.0 VOLTS: 120 0.3 7 PROVIDENCE CONVENIENCE OUTLETS A 20 1 0.3 2.5 208 0.4 9 SOFTLAYER CONVENIENCE OUTLETS B 20 1 0.4 3.3 PH: 3 0.4 11 SOFTLAYER CONVENIENCE OUTLETS C 20 1 0.4 3.3 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 _ C 20 1 _ 0.0 0.0 FLUSH: 25 A 20 1 l 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 0.4 2 KCDC CONVENIENCE OUTLETS A 20 1 0.4 3.3 PANEL T.C.L. 0.4 4 KCDC CONVENIENCE OUTLETS B 20 1 0.4 3.3 LOAD (kVA) 0.4 , 6 KCDC CONVENIENCE OUTLETS C 20 1 0.4 3.3 RCPT 2.7 0.2 , 8 CORRIDOR OUTSIDE KCDC OUTLETS A 20 1 0.2 1.5 LTG 0.0 10 B 20 1 0.0 0.0 EQP 1.4 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 16 B 0.0 0.0 TOTAL 4.1 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. t 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 2.7 26 A 0.0 0.0 LTG 0.0 28 B r 0.0 0.0 EQP 1.4 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 4.1 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 4.1 42 C 0.0 0.0 AMPS 11.3 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 2.7 0.0 1.4 0.0 KVA/AMPS: 1.7 14.0 1.6 13.3 0.8 6.7 __ Mfg/Type: Square D _ . 1.1 0.0 0.6 0.0 A CB Type: _____ _____ _ 1.2 0.0 0.4 0.0 B Remarks: __ _ _`_ _. __ _ . _ -____, 0.4 0.0 0.4 0.0 C -_. -. __ VECA Electric PANEL: .52A -L3 _ , FEED -THRU: ROOM: 3RD FLOOR MECHANICAL ROOM LOADS FROM: _ M -52A VIA XFMR 52A -L3 A B C RCPT LTG EQP I HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA TAMPS KVA AMPS 0.3 1 ROOF RECEPTACLE A 20 1 0.3 2.5 0.8 3 HEAT TRACE B 20 1 0.8 6.7 AMP: 100 0.3 5 CONVENIENCE RECEPTACLE C 20 1 0.3 2.5 VOLTS: 120 7 A 20 1 0.0 0.0 208 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 1.0 2 AHU 52A -1 CONTROLS /ACTUATORS A 20 1 1.0 8.3 PANEL T.C.L. 1.0 4 AHU 52A -2 CONTROLS /ACTUATORS B 20 1 1.0 8.3 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 3.4 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 i 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 J 16 B 0.0 0.0 TOTAL 3.4 18 C 0.0 0.0 c 20 A 0.0 0.0 FEEDER T.C.L. f 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 3.4 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0. J EQP 0.0 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 3.4 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 3.4 42 C 0.0 0.0 AMPS 9.4 - A 0.0 0.0 - g 0.0 0.0 - C 0.0 0.0 3.4 0.0 0.0 0.0 KVA/AMPS 1.3 10.8 1.8 15.0 0.3 2.5 MfgfType: Square D 1.3 0.0 0.0 0.0 A - - -- -- -- -- CB Type: -- ...- - - - - -- 1.8 0.0 0.0 0.0 B Remarks: - 0.3 0.0 0.0 0.0 C VECA Electric SWBD HDP52B Phase A ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: UNIT SUBSTATION TB -52 RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 375.0 UPS 52 -B1 PRIMARY 1200 3 375 451 UPS 52 -B1 STATIC BYPASS 1200 3 - - AMP: 4000 MBP -52 -B1 MAINT BYPASS 1200 3 - - VOLTS: 277 375.0 UPS 52 -B2 PRIMARY 1200 3 375 451 480 UPS 52 -B2 STATIC BYPASS 1200 3 - - PHASE: 3 MBP -52 -B2 MAINT BYPASS 1200 3 - - WIRE: 3 375.0 UPS 52 -B3 PRIMARY 1200 3 375 451 BUS: CU UPS 52 -B3 STATIC BYPASS 1200 3 - - A.I.C.: 65K MBP -52 -B3 MAINT BYPASS 1200 3 - - M.L.O.: UPS 52 -B4 PRIMARY (FUTURE) 800 j 3 - - MAIN CB: YES UPS 52 -B4 STATIC BYPASS (FUTURE) 800 3 - - FUSE: MBP -52 -B4 MAINT BYPASS (FUTURE) 800 H 3 - - FLUSH: 2.9 0.0 1225.0 0.0 M -52 -B MECHANICAL PANEL 3rd FLOOR 1600 3 1,228 1,477 SURF: YES 8.0 52B -H1 LIGHTING VIA 30 KVA 50 3 8 10 l 60.0 RF -5203C 2nd FLOOR PROVIDENCE 100 3 60 72 TVSS 100 3 - - IG GND: 74.0 89.0 293.0 COMMON AREA LOAD 1200 3 456 548 200% N: 2.7 0.0 4.5 0.0 TRANSFORMER 52B -L1 50 3 7 9 FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT 80 - - LTG 97 - - EQP 2,708 - - HEAT - - - TOTAL 2,884 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 80 - - LTG 97 - - EQP 2,708 - - HEAT - - - TOTAL 2,884 - - FEEDER DEMAND - - kVA 2,874 TOTAL F 2,884 3,469 AMPS 3,456 80 97 2,708 - MFG: ' SQ D , -- . -- ._ . - NOTE: - - Project. NORMAL 10/26/09 SWITCHBOARD HAS DUAL INPUT BREAKERS WITH AUTOMATIC TRANSFER FROM -TO GENERATOR POWER.— -- — — SDC 52 Central Plant VECA Electric swim M -52 -B :Phase A ROOM: 3RD FLOOR MECHANICAL ROOM HDP -52B LOAD DISTRIBUTION FROM: RCPT LTG EQP HEAT DESCRIPTION AMP P kVA A AMPS 17.5 AHU -52 -B2 North UPS Room (Central Plant) 40 3 18 21 9.0 RF -52B UPS Room (Central Plant) 20 3 9 11 AMP: 1600 51.0 RF -5203B 2nd Floor (Providence) 100 3 51 61 VOLTS: 277 51.0 RF-5201B 2nd Floor (King County) 100 3 51 61 480 2.5 EF- 5201 -1 2nd Floor (King County) 20 3 3 3 PHASE: 3 128.0 AHU -52 -B1 3RD Floor (Central Plant) 225 3 128 154 WIRE: 3 2.9 0.0 0.0 0.0 TRANSFORMER 52B -L3 3rd Floor (Central Plant) 50 3 3 3 BUS: CU 218.0 CH -52 -B1 Roof (Central Plant) 350 3 218 262 A.I.C.: 65K 218.0 CH -52 -B1 Roof (Central Plant) 350 3 218 262 M.L.O.: YES 218.0 CH -52 -B2 Roof (Central Plant) 350 3 218 262 MAIN CB: 218.0 CH -52 -B2 Roof (Central Plant) 350 3 218 262 FUSE: 24.0 CHP -52B Roof (Central Plant) 40 3 24 29 FLUSH: 1 19.0 25% of the Largest Motor 19 1 23 SURF: YES l a - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: 51.0 RF -5201C 2nd Floor (King County) 100 3 51 61 BTM: YES - - PANEL T.C.L. LOAD (kVA) - - RCPT 3 - - LTG - 1,225^ - - EQP - - HEAT - - TOTAL 1,228 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 3 - - LTG - - EQP 1,225 - - HEAT - - - TOTAL 1,228 - - FEEDER DEMAND - - kVA 1,228 TOTAL 1.228 1,477 AMPS 1,477 3 - 1,225 - MFG: SQ D -- CB: NOTE: Project: — — SDC Central Plant 10/26/09 VECA Electric PANEL: 52B -H1 ROOM: FUTURE FEED -THRU: LOADS FROM: HDP -52B A B C 1 RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS P.0 1 PROVIDENCE DATA CENTER LIGHTS A 20 1 2.0 7.2 2.0 3 KING COUNTY DATA CENTER LIGHTS B 20 1 2.0 7.2 AMP: 100 2.0 5 PROVIDENCE OFFICE LIGHTS C 20 1 2.0 7.2 VOLTS: 277 2.0 7 GENERATOR ROOM LIGHTS _ A 20 1 2.0 7.2 480 2.0 9 UPS ROOM LIGHTS B 20 1 2.0 7.2 PH: 3 2.0 11 SOFTLAYER DATA CENTER LIGHTS C 20 1 2.0 7.2 WIRE: 4 13 - A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 1 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0,0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A 20 1 0.0 0.0 LTG 12.0 10 1 B 20 1 0.0 0.0 EQP 4.8 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 16 B 0.0 0.0 TOTAL 16.8 18 C 0.0 0.0 c 0.8 20 EXHAUST FAN 52B -1 A 20 3 0.8 2.9 FEEDER T.C.L. r, 0.8 22 EXHAUST FAN 52B -1 B " " 0.8 2.9 LOAD (kVA) 0.8 24 EXHAUST FAN 52B -1 C " 0.8 2.9 RCPT 0.0 0.8 26 EXHAUST FAN 52B -2 A 20 3 0.8 2.9 LTG 12.0 0.8 28 EXHAUST FAN 52B -2 B 0.8 2.9 EQP 4.8 0.8 30 EXHAUST FAN 52B -2 C 0.8 2.9 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 16.8 36 C ~ 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 19.8 42 C 20 1 0.0 0.0 AMPS 23.8 - A 0.0 0.0 B " 0.0 0.0 - C " 0.0 0.0 0.0 12.0 4.8 0.0 KVA/AMPS: 5.6 20.2 5.6 20.2 5.6 20.2 Mfg/Type' ' -- - CB Type: 0.0 4.0 1.6 0.0 A _______-__ _ - ______ -__ _._ _ Remarks: - ______ .__ -__ _____ 0.0 4.0 1.6 0.0 B .__...__ _ 0.0 4.0 1.6 0.0 C • _ VECA Electric PANEL: '52B -L1 ROOM: SDC 52 GENERATOR ROOM FEED -THRU: LOADS FROM: HDP -52B VIA XFMR 52B -L1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS _ _ 1.5 1 GENERATOR B BLOCK HEATER A 20 1 1.5 12.5 1.5 3 GENERATOR B BLOCK HEATER B 20 1 1.5 12.5 AMP: 100 0.5 5 GENERATOR B BATTERY CHARGER C 20 1 0.5 4.2 VOLTS: 120 7 SPARE A 20 1 0.0 0.0 208 0.5 9 DAY TANK 52B CONTROLS B 20 1 0.5 4.2 PH: 3 0.5 11 HEAT TRACE C 20 1 0.5 4.2 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 1.1 0.0 0.0 0.0 2 PANEL 52B -L2 A 20 1 1.1 9.2 PANEL T.C.L. 1.2 0.0 0.0 0.0 4 PANEL 52B -L2 B 20 1 1.2 10.0 LOAD (kVA) 0.4 0.0 0.0 0.0 6 PANEL 52B -L2 C 20 1 0.4 3.3 RCPT 2.7 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 4.5 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 i 16 B " 0.0 0.0 TOTAL 7.2 18 C 0.0 0.0 ti 20 A 30 3 0.0 0.0 FEEDER T.C.L. e 22 B 0.0 0.0 LOAD (kVA) 24 C " " 0.0 0.0 RCPT 2.7 26 A 30 3 0.0 0.0 LTG 0.0 28 B " 0.0 0.0 EQP 4.5 30 C " " 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 7.2 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 7.2 42 C 20 1 0.0 0.0 AMPS 20.0 A 0.0 0.0 B " 0.0 0.0 - C 0.0 0.0 2.7 0.0 4.5 0.0 KVA/AMPS: 2.6 21.7 3.2 26.7 1.4 11.7 I Mfg/Type: Square D 1.1 0.0 1.5 0.0 A CB Type: - - -_ -- . - - - 1.2 0.0 2.0 0.0 B Remarks: - 0.4 0.0 1.0 0.0 C - _-- - -- -- __ -___- VECA Electric PANEL: 52B -L2 FEED -THRU: ROOM: 2ND FLOOR ELECTRICAL CLOSET LOADS FROM: PANEL 52B -L1 A 1 B C I RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 0.8 1 ACCO BUILDING CONTROLS A 20 1 0.8 6.7 0.8 3 ACCO BUILDING CONTROLS B 20 1 0.8 6.7 AMP: 100 5 SPARE C 20 1 0.0 0.0 VOLTS: 120 0.3 7 PROVIDENCE CONVENIENCE OUTLETS A 20 1 0.3 2.5 208 0.4 9 SOFTLAYER CONVENIENCE OUTLETS B 20 1 0.4 3.3 PH: 3 0.4 11 SOFTLAYER CONVENIENCE OUTLETS C 20 1 0.4 3.3 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 2.7 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0, 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 A 20 3 0.0 0.0 1 16 B 0.0 0.0 TOTAL 2.7 C " 0.0 0.0 c A 30 3 0.0 0.0 FEEDER T.C.L. t 22 B 0.0 0.0 LOAD (kVA) 24 C " 0.0 0.0 RCPT 2.7 26 A 30 3 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C " " 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 2.7 J 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B " " 0.0 0.0 kVA 2.7 42 C 20 1 0.0 0.0 AMPS 7.5 - A 0.0 0.0 - B 0.0 0.0 - C " " 0.0 0.0 2.7 1.1 0.0 0.0 0.0 0.0 0.0 0.0 A KVA/AMPS: 1.1 9.2 1.2 10.0 0.4 3.3 , MfgfType: Square D _ - -_ - - - CB Type: 1.2 0.4 0.0 0.0 0.0 0.0 0.0 0.0 B C ________ - _______ Remarks: - __ VECA Electric PANEL: 52B -L3 ROOM: 3RD FLOOR MECHANICAL R OOM M -52B VIA XFMR 52B -L3 FEED -THRU: FROM: A B C LOADS RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 0.8 1 ROOF RECEPTACLE A 20 1 0.8 6.7 D.8 3 HEAT TRACE B 20 1 0.8 6.7 AMP: 100 0.3 5 CONVENIENCE RECEPTACLE C 20 1 0.3 2.5 VOLTS: 120 7 A 20 1 0.0 0.0 208 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 l 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND l 33 B 1 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.01 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 1.0 2 AHU 52 -B1 CONTROLS /ACTUATORS A 20 1 1.0 8.3 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 2.9 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 16 B 0.0 0.0 TOTAL 2.9 18 C 0.0 0.0 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. f 22 B " " 0.0 0.0 LOAD (kVA) 24 C " " 0.0 0.0 RCPT 2.9 26 A 30 3 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 2.9 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 2.9 42 C 20 1 0.0 0.0 AMPS _ 8.0 - A 0.0 0.0 - B 0.0 0.0 - C " 0.0 0.0 2.9 0.0 0.0 0.0 KVA/AMPS 1.81 15.0 0.81 6.7 0.3 2.5 Mfg/Type: Square D - - -.- --- A B - -- - - - - -- CB Type: 1.8 0.0 0.0 0.0 . Remarks: - 0.8 0.0 0.0 0.0 C _ 0.3 0.0 0.0 0.0 - - -- - - - - -- VEGA Electric SWBD MBP -52 -A1 _ _Phase ROOM: SDC 52 MAIN ELEC ROOM HDP -52A LOAD DISTRIBUTION FROM. RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 125.0 STS -AB1 PROVIDENCE 400 3 125 150 125.0 STS -AC1 PROVIDENCE 400 3 125 150 AMP: 1200 125.0 STS -AD1 SOFTLAYER TEMP BC1 400 3 125 150 VOLTS: 277 STS -BA1 400 3 - - 480 STS -CA1 400 3 - - PHASE: 3 STS -DA1 400 3 - - WIRE: 3 - BUS: CU - - A.I.C.: 65K - M.L -O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - LTG - _ - EQP 375 - - HEAT - - - TOTAL 375 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 375 - HEAT - - TOTAL 375 - - FEEDER DEMAND - - kVA 375 TOTAL 375 451 AMPS 451 - 375 - MFG: SQ D CB SQ D 10/26/09 NOTE: Project: SDC 52 Central Plant - _ _ VECA Electric SWBD MBP -52 -A2 _ _ _ _ :Ph_a_se A_ _ ROOM: SDC 52 MAIN ELEC ROOM - LOAD DISTRIBUTION FROM: HDP -52A RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 125.0 STS -AB2 KCDC 400 3 125 150 125.0 STS -AC2 KING COUNTY 400 3 125 150 AMP: 1200 125.0 STS -AD2 SOFTLAYER TEMP FOR BC2 400 3 125 150 VOLTS: 277 STS -BA2 400 3 - 480 STS -CA2 400 3 - - PHASE: 3 STS -DA2 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 375 - - HEAT - - - TOTAL 375 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - EQP 375 - - HEAT - - - TOTAL 375 - - FEEDER DEMAND - - kVA 375 TOTAL 375 451 AMPS 451 375 - MFG: ' SQ D CB: .SQ NOTE: Project: .SDC D - -- - - -_ 10/26/09 -- 52 Central Plant - VECA Electric SWBD MBP -52 -A3 'Phase A ROOM SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52A RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 125.0 STS -AB3 SOFTLAYER 400 3 125 150 125.0 STS -AC3 KING COUNTY 400 3 125 150 AMP: 1200 125.0 STS -AD3 SOFTLAYER TEMP FOR BC3 400 3 125 150 VOLTS: 277 STS -BA3 400 3 - - 480 STS -CA3 400 3 - - PHASE: 3 STS -DA3 400 3 - T - WIRE: 3 - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 375 - - HEAT - - - TOTAL 375 - - FEEDER T.G.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 375 - - HEAT - - - TOTAL 375 - - FEEDER DEMAND - - kVA 375 TOTAL 375 451 AMPS 451 - 375 - MFG: 'SQ D -- — CB: NOTE: Project: • SQ D -- - - - -- - -- - – -- — — — SDC 52 Central Plant 10/26/09 - VECA Electric SWBD MBP -52 -B1 _ ROOM: SDC 52 MAIN ELEC ROOM :Phase A LOAD DISTRIBUTION FROM: HDP -52B RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 125.0 STS -BA1 PROVIDENCE 400 3 125 150 125.0 STS -BC1 SOFTLAYER 400 3 125 150 AMP: 1200 125.0 STS -BD1 PROVIDENCE TEMP FOR AC1 400 3 125 150 VOLTS: 277 STS -AB1 400 3 - - 480 STS -CB1 400 3 - - PHASE: 3 STS -DB1 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. r - - LOAD (kVA) RCPT - - - LTG - EQP 375 - - HEAT - - TOTAL 375 - - FEEDER T.C.L. _ - LOAD (kVA) - - RCPT - - - LTG - - - EQP 375 - - HEAT - - - TOTAL 375 - - FEEDER DEMAND - - kVA 375 TOTAL 375 451 AMPS 451 - 375 - MFG: SQ D i 'SQ D _ICB: -- -- NOTE: ' Project: .SDC 52 Central Plant 10126/02 VELA Electric SWBD MBP -52 -B2 I _ •PhaseA____ _ ROOM: SDC 52 MAIN ELEC ROOM HDP -52B — LOAD DISTRIBUTION FROM: RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 125.0 STS -BA2 KCDC 400 3 125 150 125.0 STS -BC2 SOFTLAYER 400 3 125 150 AMP: 1200 125.0 STS -BD2 KCDC TEMP FOR AC2 400 3 125 150 VOLTS: 277 STS -AB2 400 3 - - 480 STS -CB2 400 3 - - PHASE: 3 STS -DB2 400 3 - - WIRE: 3 - - BUS: Cu A.l.C.: 65K - - M.L.O.: - - MAIN CB: YES - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 375 - - HEAT - J - - - TOTAL 375 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 375 - - HEAT - - - TOTAL 375 - - FEEDER DEMAND - - kVA 375 TOTAL II 375 451 AMPS 451 - - 375 - MFG: ISQ D - — -- CB: ISO D — - - - -- - - -- — — NOTE: — — — 10/26/09 Project: •SDC 52 Central Plant — VECA Electric SWBD MBP -52 -B3 PhaseA_ ' ROOM: SDC 52 MAIN ELEC ROOM • LOAD DISTRIBUTION FROM: HDP -52B RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 125.0 STS -BA3 SOFTLAYER 400 3 125 150 125.0 STS -BC3 SOFTLAYER 400 3 125 150 AMP: 1200 125.0 STS -BD3 KING COUNTY TEMP FOR AC3 400 3 125 150 VOLTS: 277 STS -AB3 400 3 - - 480 STS -CB3 1 400 3 - - PHASE: 3 STS -DB3 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K T - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 375 - - HEAT - - - TOTAL 375 i - - FEEDER T.C.L. - - LOAD (kVA) _4 - - RCPT - - - LTG - - - EQP 375 ? - - HEAT - - - - TOTAL 375 - - FEEDER DEMAND - - kVA 375 TOTAL 375 451 AMPS 451 - - 375 - MFG: SQ D I NOTE: Project: .SDC 52 Central Plant 10/26/09 ' _ _ VECA Electric PANEL: PDC 52 -AB3 -1 Sect.1 -THRU: Phase A POD #1 ROOM SOFTLAYER FEED LOADS FROM: STS 52 -AB3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.3 1 RACK #2 L6 -20 A 20 2 1.3 10.8 1.3 3 RACK #2 L6 -20 B 1.3 10.8 AMP: 400 1.3 5 RACK #2 L6 -20 C 20 2 1.3 10.8 VOLTS: 120 1.3 7 RACK #2 L6 -20 A 1.3 10.8 208 • 1.3 9 RACK #2 L6 -20 B 20 2 1.3 10.8 PH: 3 1.3 11 RACK #2 L6 -20 C 1.3 10.8 WIRE: 4 1.3 13 RACK #2 L6 -20 A 20 2 1.3 10.8 BUS: AL 1.3 15 RACK #2 L6 -20 B 1.3 10.8 A.I.C.: 18K 1.9 17 RACK #3 L6 -30 C 30 2 1.9 15.8 MLO: YES 1.9 19 RACK #3 L6 -30 A 1.9 15.8 MCB: 1.9 21 RACK #3 L6 -30 B 30 2 1.9 15.8 3R: 1.9 23 RACK #3 L6 -30 C 1.9 15.8 FLUSH: 1.9 25 RACK #4 L6 -30 A 30 2 1.9 15.8 SURF: YES 1.9 27 RACK #4 L6 -30 B 1.9 15.8 1.9 29 RACK #5 L6 -30 C 30 2 1.9 15.8 1.9 31 RACK #5 L6 -30 A 1.9 15.8 IG GRND. 1.9 33 RACK #12 L6 -30 B 30 2 1.9 15.8 200% N: 1.9 35 RACK #12 L6 -30 C 1.9 15.8 FD THRU NO 1.9 37 RACK #13 L6 -30 A 30 2 1.9 15.8 DBL LUG 1.9 39 RACK #13 L6 -30 B 1.9 15.8 TOP: YES 41 SPACE C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 33.2 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 33.2 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REFI #REF! #REF! 0.0 #REF! FEED A #REFI #REF! #REF! #REF! 0.0 #REFI THRU B #REF! #REFI #REF! #REF! 0.0 #REF! LUGS C " #REF! #REF! #REF! #REFI 33.2 #REFI KVA/AMPS :I #REF! #REFI #REF! #REF! #REF! #REF! Mfg/Type: Square D #REF! #REFI 11.5 #REF! A CB Type: Square D #REF! #REF! 11.5 #REFI B Remarks: Outlet Loads #REF! #REFI 10.2 #REF! C VECA Electric PANEL: : PDC 52 -AB3 -1 Sect.2 POD # 1 ROOM SOFTLAYER _ FEED -THRU: Phase A LOADS FROM: STS 52 -AB3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA [AMPS KVA AMPS KVA AMPS 1.9 1 RACK #14 L6 -30 A 20 2 1.9 15.8 1.9 3 RACK #14 L6 -30 B 1.9 15.8 AMP: 400 1.9 5 RACK #15 L6 -30 C 20 2 1.9 15.8 VOLTS: 120 1.9 7 RACK #15 L6 -30 A 1.9 15.8 208 1.9 9 RACK #16 L6 -30 B 20 2 1.9 15.8 PH: 3 1.9 11 RACK #16 L6 -30 C 1.9 15.8 WIRE: 4 1.9 13 RACK #18 L6 -30 A 20 2 1.9 15.8 BUS: AL 1.9 15 RACK #18 L6 -30 B 1.9 15.8 A.I.C.: 18K 1.9 17 RACK #19 L6 -30 C 30 2 1.9 15.8 MLO: YES 1.9 19 RACK #19 L6 -30 A 1.9 15.8 MCB: 1.9 21 RACK #20 L6 -30 B 30 2 1.9 15.8 3R: 1.9 23 'RACK #20 L6 -30 C 1.9 15.8 FLUSH: 1.9 25 RACK #21 L6 -30 A 30 2 1.9 15.8 SURF: YES 1.9 27 RACK #21 L6 -30 B 1.9 15.8 1.9 29 RACK #22 L6 -30 C 30 2 1.9 15.8 1.9 31 RACK #22 L6 -30 A 1.9 15.8 IG GRND. 33 SPACE B 0.0 0.0 200% N: 35 SPACE C 0.0 0.0 FD THRU NO 37 SPACE A 0.0 0.0 DBL LUG. 39 SPACE B 0.0 0.0 TOP: YES 41 SPACE C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 30.4 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.G.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 30.4 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 1 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REFI #REF! #REFI 0.0 #REFI FEED A #REFI #REFI #REF! *REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C " " #REF! #REF! #REF! #REF! 30.4 *REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D #REF' #REF! 11.4 #REF! A CB Type: Square D #REF! #REF! 9.5 #REF! B Remarks: Outlet Loads #REF! #REF! 9.5 #REF! C . VECA Electric PANEL: : PDC 52 -BA3 -1 Sect.1 POD #1 -THRU: 'Phase A • ROOM. SOFTLAYER STS 52 -BA3 FEED LOADS FROM: A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P _ KVA AMPS KVA AMPS KVA AMPS 1.3 1 RACK #2 L6 -20 A 20 2 1.3 10.8 1.3 3 RACK #2 L6 -20 B 1.3 10.8 AMP: 400 1.3 5 RACK #2 L6 -20 C 20 2 1.3 10.8 VOLTS: 120 1.3 7 RACK #2 L6 -20 A 1.3 10.8 208 1.3 9 RACK #2 L6 -20 B 20 2 _ 1.3 10.8 PH: 3 1.3 11 RACK #2 L6 -20 C 1.3 10.8 WIRE: 4 1.3 13 RACK #2 L6 -20 A 20 2 1.3 10.8 BUS: AL 1.3 15 RACK #2 L6 -20 B 1.3 10.8 A -I.C.: 18K 1.9 17 RACK #3 L6 -30 C 30 2 1.9 15.8 MLO: YES 1.9 19 RACK #3 L6 -30 A 1.9 15.8 MCB: 1.9 21 RACK #3 L6 -30 B 30 2 1.9 15.8 3R: 1.9 23 RACK #3 L6 -30 C 1.9 15.8 FLUSH: 1.9 25 RACK #4 L6 -30 A 30 2 1 1.9 15.8 SURF: YES 1.9 27 RACK #4 L6 -30 B 1.9 15.8 1.9 29 RACK #5 L6 -30 C 30 2 1.9 15.8 1.9 31 RACK #5 L6 -30 A 1.9 15.8 IG GRND. 1.9 33 RACK #12 L6 -30 B 30 2 1.9 15.8 • 200% N: 1.9 35 RACK #12 L6 -30 C 1.9 15.8 FD THRU NO 1.9 37 RACK #13 L6 -30 A 30 2 1.9 15.8 DBL LUG. 1.9 39 RACK #13 L6 -30 B 1.9 15.8 TOP: YES 41 SPACE C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 33.2 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 33.2 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REFI #REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C #REF! #REF! #REF! #REF! 33.2 #REF! KVA/AMPS:I #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D : #REF! #REF! 11.5 #REF! A CB Type: Square D #REF! #REF! 11.5 #REF! B Remarks: Outlet Loads #REF! #REF! 10.2 #REF! C I VECA Electric PANEL: ' PDC 52 -BA3 -1 Sect. 2 POD #1 ROOM: SOFTLAYER FEED -THRU: Phase A LOADS FROM: STS 52 -BA3 A B C RCPT[ LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.9 1 RACK #14 L6 -30 A 20 2 1.9 15.8 1.9 3 RACK #14 L6 -30 B 1.9 15.8 AMP: 400 1.9 5 RACK #15 L6 -30 C 20 2 1.9 15.8 VOLTS: 120 1.9 7 RACK #15 L6 -30 A 1.9 15.8 208 1.9 9 RACK #16 L6 -30 B 20 2 1.9 15.8 PH: 3 1.9 11 RACK #16 L6 -30 C 1.9 15.8 WIRE: 4 1.9 13 RACK #18 L6 -30 A 20 2 1.9 15.8 BUS: AL 1.9 15 RACK #18 L6 -30 B 1.9 15.8 A.I.C.: 18K 1.9 17 RACK #19 L6 -30 C 30 2 1.9 15.8 MLO: YES 1.9 19 RACK #19 L6 -30 A 1.9 15.8 MCB: 1.9 21 RACK #20 L6 -30 B 30 2 1.9 _ 15.8 3R: 1.9 23 RACK #20 L6 -30 C 1.9 15.8 FLUSH: 1.9 25 RACK #21 L6 -30 A 30 2 1.9 15.8 SURF: YES 1.9 27 RACK #21 L6 -30 B 1.9 15.8 1.9 29 RACK #22 L6 -30 C 30 2 1.9 15.8 1.9 31 RACK #22 L6 -30 A 1.9 15.8 IG GRND. 33 SPACE B 0.0 0.0 200% N: 35 SPACE C 0.0 0.0 FD THRU NO 37 SPACE A 0.0 0.0 DBL LUG 39 SPACE B 0.0 0.0 TOP: YES 41 SPACE C 0.0 0.0 BTM: 7 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT *REF! 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 30.4 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 30.4 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REFI 0.0 #REF! THRU B " #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C " " #REF! #REF! #REF! #REF! 30.4 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! ' _ _ Mfg/Type: Square D #REF! #REF! 11.4 #REF! A CB Type: Square D #REF! #REF! 9.5 #REF! B Remarks: Outlet Loads #REF! #REF! 9.5 #REF! C VECA Electric PANEL: PDC 52 -AB3 -2 Sect.1 • POD #2 FEED -THRU: Phase A ROOM: SOFTLAYER LOADS FROM: STS 52 -AB3 A B C RCPT LTG 1 EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS - 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 i RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 J 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.81 FLUSH 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND. 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C J 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF! #REFI #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REFI 0.0 #REF! THRU B #REFI #REF! #REF! #REF! 0.0 #REF! LUGS " C " #REFI #REF! #REF! #REF! 50.0 #REF! KVA/AMPS: #REF! #REFI #REF! #REF! #REFI #REF! Mfg/Type: Square D #REF! #REF! 17.5 #REF! A CB Type: Square D #REF' #REFI 17.5 #REF! B Remarks: Outlet Loads #REF! #REF! 15.0 #REF! C VECA Electric PANEL: PDC 52 -AB3 -2 Sect. 2 POD #2 FEED -THRU: Phase A ROOM: SOFTLAYER LOADS FROM: STS 52 -AB3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #12 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #12 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #13 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6 -30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 17 C 0.0 0.0 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG. 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 20.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 20.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF? #REFI #REF! 0.0 #REF! FEED A #REF! #REF! #REFI #REFI 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS " C #REF! #REF! #REFI #REFI 20.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type:_Square D #REF! #REF! 7.5 #REF! A CB Type: Square D #REF! #REF! 7.5 #REF! B Remarks: Outlet Loads #REFI #REF! 5.0 #REF! C _ _ VECA Electric PANEL: PDC 52 -BA3 -2 Sect.1 -THRU: Phase A POD #2 _ ROOM: SOFTLAYER FEED T LOADS FROM STS 52 -BA3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA (AMPS - --I 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND. 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A , 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REFI 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REFI #REF! 0.0 #REF! LUGS C #REF! #REF! #REF! #REF! 50.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REFI Mfg/Type: Square D _ #REF! #REF! 17.5 #REF! A CB Type: Square D #REF! #REF! 17.5 #REF! B Remarks: Outlet Loads I #REF! #REF! 15.0 #REF! C _ VECA Electric PANEL: PDC 52 -BA3 -2 Sect.2 POD #2 ROOM: SOFTLAYER FEED -THRU: Phase A LOADS FROM: STS 52 -BA3 A [ B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #12 L6 -30R A 20 2 2.5 20.8 2.5 3 RACK #12 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #13 L6 -30R C 20 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6 -30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 20 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R A 20 2 2.5 20.8 BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 C 2.5 20.8 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND. 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG: 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 22.5 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 22.5 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REFI 0.0 #REFI LUGS C " #REF! #REF! #REF! #REF! 22.5 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D #REF! #REF! 7.5 #REF! A CB Type: Square D #REF! #REF! 7.5 #REFI B Remarks: Outlet Loads #REF! #REF! 7.5 #REF! C - - - -- - ' VECA Electric PANEL: PDC 52 -BC1 -1 Sect.1 POD #3 LOADS ROOM: FROM: SOFTLAYER FEED -THRU: Phase A STS 52 -BC1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 - 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG. 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REFI 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0,0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REFI #REF! 0.0 #REF! FEED A #REF! #REF! #REFI #REF! 0.0 #REF! THRU B " #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C #REF! #REF! #REF! #REF! 50.0 #REF! KV/VAMPS: #REFI #REF! #REF! #REF! #REF! #REF! #REFI #REF! #REFI *REF! 17.5 17.5 #REFI #REFI A B Mfg /Type: Square D __ ^_ __ _, __ CB Type: Square D __ J__ _ _._ . __ Remarks: Outlet Loads ___ _ _. _ ____ #REF! #REF! 15.0 #REF! C VECA Electric PANEL- • PDC 52 -BC1 -1 Sect. 2 POD #3 FEED -THRU: Phase A ROOM: SOFTLAYER LOADS FROM: STS 52 -BC1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #12 L6 -30R A 30 2 2.5 20.8 ________ 2.5 3 RACK #12 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #13 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6 -30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 17 C 0.0 0.0 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND. 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG. 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 20.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 20.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REFI #REF! #REFI 0.0 #REFI FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B " #REF! #REF! #REF! #REF! 0.0 #REFI LUGS C " #REF! #REF! #REF! #REF! 20.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! _ Mfg/Type: Square D #REF! #REF! 7.5 #REF! A CB Type: Square D #REF! #REFI 7.5 #REF! B Remarks: Outlet Loads #REF! #REF! 5.0 #REFI C VECA Electric PANEL: PDC 52 -CB1 -THRU: Phase -1 Sect.1 POD #3 . ROOM: SOFTLAYER FEED A • LOADS FROM: STS 52 -CB1 A B C , RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND. 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG. 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REFI 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REFI #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C #REF! #REFI #REF! #REF! 50.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D • #REF! #REF! 17.5 #REF! A CB Type: Square D #REF! #REF! 17.5 #REF! B Remarks: Outlet Loads #REF! #REF' 15.0 #REF! C _ _ _ _ - VECA Electric PANEL: PDC 52 -CBI -1 Sect. 2 . POD #3 ROOM: SOFTLAYER STS 52 -CB1 FEED -THRU: Phase A FROM: A B C • LOADS RCPT LTG EQP I HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 RACK #12 L6 -30R A 30 2 2.5 20.8 2.5 2.5 3 RACK #12 L6 -30R 0 2.5 20.8 AMP: 400 2.5 5 r RACK #13 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6 -30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 17 C _ 0.0 0.0 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 1 2 1 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 20.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 20.0 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B " " #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C #REF! #REF! #REF! #REF! 20.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D A _ CB Type: Square D #REFI #REF! 7.5 #REF! B ____ Remarks: Outlet Loads -_ _ ._ -_ ____- ____ . ___ #REF! #REF! 7,5 #REF! #REF! #REF! 5.0 #REF! C VECA Electric PANEL: PDC 52-BC1 -2 Sect.1 POD #4 ROOM: SOFTLAYER STS 52 -BC1 FEED -THRU: !Phase A LOADS FROM: A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0I BTM: i 1 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REFI 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REFI FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B " #REF! #REF! #REF! #REF! 0.0 #REF! LUGS " C #REF! #REF! #REF! #REF! 50.0 #REF! KVA/AMPS: #REFI #REF!_ #REF! #REF! #REF! #REFI Mfg /Type: Square D #REF! #REF! 17.5 #REF! A CB Type: Square D #REF! #REF! 17.5 #REF! B Remarks: Outlet Loads #REF! #REFT 15.0 #REF! C VECA Electric PANEL: PDC S2 -BC1 -2 Sect. 2 POD #4 ROOM. SOFTLAYER STS 52 -BC1 FEED -THRU: Phase A FROM: A B C LOADS RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #12 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #12 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #13 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6 -30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R A 30 2 2.5 20.8 _ BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 17 C 0.0 0.0 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A f 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: FD THRUI NO y 35 1 C 0.0 0.0 37 A 0.0 0.0 DBL LUG 39 B 0,0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 20.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 20.0 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REFI #REFI #REF! 0.0 #REF! FEED A #REF! #REF! #REFI #REFIL 0.0 #REFI THRU B #REF! #REF! #REFI #REFI 0.0 #REF! LUGS C #REF! #REF! #REF! #REFI 20.0 #REFI KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D #REF! #REF. 7.5 #REF! A CB Type: Square D . _ _ _- __ • #REF! #REF! 7.5 #REF! B Remarks. Outlet Loads #REF! #REF! 5.0 #REF! C .'_ - -- - -- l -- �- -- - - -- - ' - - -- VECA Electric PANEL: PDC 52 -CB1 -2 Sect. 1 POD #4 FEED -THRU: . Phase A ROOM: SOFTLAYER FROM: STS 52 -CB1 A B C LOADS RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2 -5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 J #REF! FEED A #REF! #REF! #REFI #REF! 0.0 #REF! THRU B ' #REF! #REF! #REF! #REF! 0.0 #REFI LUGS C #REF! #REF! #REF. #REF! 50.0 #REFI KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! MfgfType: Square D A - -- - -- - - CB Type: Square D #REF! #REF! 17.5 #REF! B Remarks: Outlet Loads -- _ - - - -- -- - -- - - - -- #REF! #REF! 17.5 #REF! C - - - -- - -- #REF! #REF! 15.0 #REF! VECA Electric PANEL: PDC 52 -CB1 -2 Sect. 2 POD #4 -THRU: Phase A ROOM: SOFTLAYER FEED LOADS FROM: STS 52 -CB1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 L 1 RACK #12 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #12 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #13 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6 -30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 17 C 0.0 0.0 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 ED THRU NO 37 A 0.0 0.0 DBL LUG 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) r 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 20.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 7 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 20.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REFI #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REFI *REF! 0.0 #REF! LUGS C #REF! #REF! #REF!, #REF! 20.0 #REFI KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! - MfglType: Square D _ -_- #REF! #REF! 7.5 #REF! A CB Type: Square D -- - #REFI #REF! 7.5 #REF! B Remarks: Outlet Loads #REF! #REF! 5.0 #REFI C _ VECA Electric PANEL: PDC 52 -BC2 -1 Sect.1 POD #5 ROOM: SOFTLAYER FEED -THRU , Phase A LOADS FROM: STS 52 -BC2 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND. 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG. 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C " #REF! #REF! #REF! #REF! 50.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D #REF! #REF! 17.5 #REF! A CB Type: Square D #REF! #REF! 17.5 #REF! B _ Remarks: Outlet Loads #REFI #REF! 15.0 #REF! C • VECA Electric PANEL: PDC 52 -BC2 -1 Sect. 2 FEED -THRU: 'Phase A ROOM: SOFTLAYER LOADS FROM _ STS 52 -BC2 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #12 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #12 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #13 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6-30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R j A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 17 C 0.0 0.0 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A , 0.0 0.0 DBL LUG 1 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 I LOAD (kVA) 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REFI 10 B f 0.0 0.0 EQP 20.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REFI 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 20.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B " #REF! #REF! 1 #REF! #REF! 0.0 #REF! LUGS C #REF! #REF! #REF! #REF! 20.0 #REF! KVA/AMPS: #REFI #REF! #REF! #REF! #REF! #REF! MfglType: Square D ._ #REF! 7.5 #REF! A CB Type: Square D #REF! #REF! 7.5 #REF! B Remarks: Outlet Loads #REF. #REF! 5.0 #REFI C #REF! VECA Electric PANEL: PDC 52 -CB2 -1 Sect.1 POD #5 Phase A ROOM SOFTLAYER STS 52 -CB2 FEED -THRU: LOADS FROM: A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REFI 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REFI 0.0 #REFI THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C #REF! #REF! #REF! #REFI 50.0 #REFI KVA/AMPS: #REF! #REF! #REF! #REF! #REF!_ #REF! Mfg/Type: Square D_ #REF! #REF! 17.5 #REFI A CB Type: Square D - - - - - - - - #REF! #REF! 17.5 #REF! B Remarks: Outlet Loads - -- - - - -- -- - -- - - #REF! #REFI 15.0 #REF! C -- - -- -- ' VECA Electric PANEL: PDC 52 -CB2 -1 Sect. 2 POD #5 ROOM: SOFTLAYER FEED -THRU: 'Phase A ' LOADS FROM: STS 52 -CB2 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #12 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #12 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #13 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6 -30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 17 C 0.0 0.0 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND. 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 20.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REFI 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 20.0 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REFI #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C " " #REF! #REFI #REF! #REF! 20.0 #REFI KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D #REF! #REF! 7.5 #REF! A CB Type: Square D #REF! #REF! 7.5 #REF! B Remarks: Outlet Loads #REF! #REF!r 5.0 #REF! C • • VECA Electric PANEL: PDC 52 -BC2 -2 Sect.1 POD #6 ROOM: SOFTLAYER FEED -THRU: Phase A LOADS FROM: STS 52 -BC2 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND 2.5 33 RACK #10 L6 -30R B 30 2 2,5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF1 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REFI #REF! 0.0 #REF! LUGS C #REF! #REF! #REF! #REFI 50.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type. Square D - -- - - -- #REF! #REF! 17.5 #REFI A CB Type: Square D #REFI #REF! 17.5 #REF! B Remarks: Outlet Loads #REF! #REF! 15.0 #REF! C - - VECA Electric P PANEL: P PDC 52 -BC2 -2 Sect. 2 POD #6 ROOM: S SOFTLAYER F FEED -THRU: P LOADS F FROM: S STS 52 -BC2 A A B B C C RCPT L LTG E EQP H HEAT C CKT D DESCRIPTION P PH A AMP P P K KVA A AMPS K KVA A AMPS K KVA A AMPS 2.5 1 1 R RACK #12 L6 -30R A A 3 30 2 2 2 2.5 2 20.8 2.5 3 3 R RACK #12 L6 -30R B B 2 2.5 2 20.8 A AMP: 4 400 2.5 5 5 R RACK #13 L6 -30R C C 3 30 2 2 2 2.5 2 20.8 V VOLTS: 1 120 2.5 7 7 R RACK #13 L6 -30R A A 2 2.5 2 20.8 2 208 2.5 9 9 R RACK #14 L6 -30R B B 3 30 2 2 2 2.5 2 20.8 P PH: 3 3 2.5 1 11 R RACK #14 L6 -30R C C 2 2.5 2 20.8 W WIRE. 4 4 2.5 1 13 R RACK #15 L6 -30R A A 3 30 2 2 2 2.5 2 20.8 B BUS: A AL 2.5 1 15 R RACK #15 L6 -30R B B 2 2.5 2 20.8 A A.I.C.: 1 18K 17 C C 0 0.0 0 0.0 M MLO: Y YES 19 A A 0 0.0 0 0.0 M MCB: 21 B B 0 0.0 0 0.0 3 3R: 23 C C 0 0.0 0 0.0 F FLUSH: 25 A A 0 0.0 0 0.0 S SURF: Y YES 27 B B 0 0.0 0 0.0 29 C C 0 0.0 0 0.0 31 A A 0 0.0 0 0.0 I IG GRND. , 33 B B 0 0.0 0 0.0 2 200% N: 35 C C 0 0.0 0 0.0 F FD THRU N NO 37 A A 0 0.0 0 0.0 D DBL LUG. 39 B B 0 0.0 0 0.0 T TOP: Y YES 41 C C 0 0.0 0 0.0 B BTM: 2 A A 0 0.0 0 0.0 P PANEL T.C.L. 4 B B 0 0.0 0 0.0 L LOAD ( (kVA) 6 C C 0 0.0 0 0.0 R RCPT # #REFI 8 A A 0 0.0 0 0.0 L LTG # #REFI 10 B B 0 0.0 0 0.0 E EQP 2 20.0 12 C C 0 0.0 0 0.0 H HEAT # #REFI 14 A A 0 0.0 0 0.0 I 1 16 B B 0 0.0 0 0.0 T TOTAL # #REFI 18 C C 0 0.0 0 0.0 20 A A 0 0.0 0 0.0 F FEEDER T.C.L. 22 B B 0 0.0 0 0.0 L LOAD ( (kVA) 24 C C 0 0.0 0 0.0 R RCPT # #REF! 26 A A 0 0.0 0 0.0 L LTG # #REFI 28 B B 0 0.0 0 0.0 E EQP 2 20.0 30 C C 0 0.0 0 0.0 H HEAT # #REF! 32 A A 0 0.0 0 0.0 34 B B 0 0.0 0 0.0 T TOTAL # #REFI 36 C C 0 0.0 0 0.0 L LG MTR 38 A A 0 0.0 0 0.0 F FEEDER DEMAND 40 B B 0 0.0 0 0.0 k kVA # #REFI 42 C C 0 0.0 0 0.0 A AMPS # #REFI #REF! # #REF! 0 0.0 # #REF! F FEED A A # #REF! # #REF! #REF! # #REF! 0 0.0 # #REF! T THRU B B # #REF! # #REF! #REF! # #REF! 0 0.0 # #REFI L LUGS - C # #REF! # #REF! #REF! # #REF! 2 20.0 # #REF! K KVA/AMPS: # #REF! # #REF! # #REFI # #REF! # #REF! # #REF! - C ---- - #REF! # #REF! 7 7.5 # #REF! A A C CB Type: Square D --- - - -.. - -- #REF! # #REF! 7 7.5 # #REF! B B R Remarks: Outlet Loads - -- - - - - - #REF! # #REF! 5 5.0 # #REF! C C - - - - -- - VECA Electric PANEL: . PDC 52 -CB2 -2 Sect.1 , POD #6 ROOM: SOFTLAYER STS 52 -CB2 FEED -THRU: !Phase A FROM: A B [ c LOADS RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #1 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #1 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #2 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #2 L6 -30R A 2.5 20.8 208 2.5 9 RACK #3 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #3 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #4 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #4 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 RACK #5 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 RACK #5 L6 -30R A 2.5 20.8 MCB: 2.5 21 RACK #7 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 RACK #7 L6 -30R C 2.5 20.8 FLUSH: 2.5 25 RACK #8 L6 -30R A 30 2 2.5 20.8 SURF: YES 2.5 27 RACK #8 L6 -30R B 2.5 20.8 2.5 29 RACK #9 L6 -30R C 30 2 2.5 20.8 2.5 31 RACK #9 L6 -30R A 2.5 20.8 IG GRND 2.5 33 RACK #10 L6 -30R B 30 2 2.5 20.8 200% N: 2.5 35 RACK #10 L6 -30R C 2.5 20.8 -, FD THRU NO 2.5 37 RACK #11 L6 -30R A 30 2 2.5 20.8 DBL LUG 2.5 39 RACK #11 L6 -30R B 2.5 20.8 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 50.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.G.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 50.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 8 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF! #REFI #REF! 0.0 #REF! FEED A #REF! #REF! #REFI #REFI 0.0 #REFI THRU B #REF! #REF! #REF! #REF! 0.0 #REFI LUGS C #REF! #REF! #REF! #REF! 50.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D ■ CB Type: Square D #REF! #REF! 17.5 #REF! A Remarks: Outlet Loads #REF! #REF! 17.5 #REF! B #REF! #REF! 15.0 #REF! C ' VECA Electric PANEL: PDC 52 -CB2 -2 Sect.2 -THRU: I . Phase A POD #6 ROOM: SOFTLAYER FEED LOADS FROM: STS 52 -CB2 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 RACK #12 L6 -30R A 30 2 2.5 20.8 2.5 3 RACK #12 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 RACK #13 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 RACK #13 L6 -30R A 2.5 20.8 208 2.5 9 RACK #14 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 RACK #14 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 RACK #15 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 RACK #15 L6 -30R B 2.5 20.8 A.I.C.: 18K 17 C 0.0 0.0 MLO: YES 19 A 0.0 0.0 MCB: 21 B 0.0 0.0 3R: 23 C 0.0 0.0 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG. 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 1 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 20.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! 18 C 0.01 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 20.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REFI #REFI #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REFI #REF! #REF! #REF! 0.0 #REF! LUGS C " #REF! #REF! #REF!I #REF! 20.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D , #REF! #REF! 7.5 #REF! A CB Type: Square D #REF! #REF! 7.5 #REF! B Remarks: Outlet Loads #REF! #REF! 5.0 #REFI C • • VECA Electric PANEL: PDC 52 -BC3 -1 S_ec_t.1_ ROOM: SOFTLAYER FEED -THRU: Phase A ' LOADS FROM: STS 52 -BC3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 POD #2 RACK 16 L6 -30R A 30 2 2.5 20.8 2.5 3 POD #2 RACK 16 L6 -30R B 2.5 20.8 I AMP: 400 2.5 5 POD #2 RACK 18 L6 -30R C 30 2 2.5 20.8 VOLTS: 120 2.5 7 POD #2 RACK 18 L6 -30R A 2.5 20.8 208 2.5 9 POD #2 RACK 19 L6 -30R B 30 2 2.5 20.8 PH: 3 2.5 11 POD #2 RACK 19 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 POD #2 RACK 20 L6 -30R A 30 2 2.5 20.8 BUS: AL 2.5 15 POD #2 RACK 20 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 POD #2 RACK 21 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 POD #2 RACK 21 L6 -30R A 2.5 20.8 MCB: 2.5 21 POD #2 RACK 22 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 POD #2 RACK 22 L6 -30R C 2.5 20.8 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND. 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG. 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2.5 2 POD #3 RACK 16 L6 -30R A 30 2 2.5 20.8 PANEL T.C.L. 2.5 4 POD #3 RACK 16 L6 -30R B 2.5 20.8 LOAD (kVA) 2.5 6 POD #3 RACK 18 L6 -30R C 30 2 2.5 20.8 RCPT #REF! 2.5 8 POD #3 RACK 18 L6 -30R A 2.5 20.8 LTG #REFI 2.5 10 POD #3 RACK 19 L6 -30R B 30 2 2.5 20.8 EQP 60.0 2.5 12 POD #3 RACK 19 L6 -30R C 2.5 20.8 HEAT #REFI 2.5 14 POD #3 RACK 20 L6 -30R A 30 2 2.5 20.8 2.5 16 POD #3 RACK 20 L6 -30R B 2.5 20.8 TOTAL #REFI 2.5 18 POD #3 RACK 21 L6 -30R C 30 2 2.5 20.8 2.5 20 POD #3 RACK 21 L6 -30R A 2.5 20.8 FEEDER T.C.L. 2.5 22 POD #3 RACK 22 L6 -30R B 30 2 2.5 20.8 LOAD (kVA) 2.5 24 POD #3 RACK 22 L6 -30R C 2.5 20.8 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 60.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C #REF! #REF! #REF! #REF! 60.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg /Type: Square D #REF! #REF! 20.0 #REF! A CB Type: Square D #REF! #REF! 20.0 #REF! B Remarks: Outlet Loads #REF! #REF! 20.0 #REF! C - - - - - -- . _ VECA Electric PANEL PDC 52 -BC3 -1 Sect.2 FEED -THRU: ' 'Phase A ROOM: FROM: SOFTLAYER STS 52 -BC3 A B C LOADS RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 POD #4 RACK 16 L6 -30R A 20 2 2.5 20.8 2.5 3 POD #4 RACK 16 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 POD #4 RACK 18 L6 -30R C 20 2 2.5 20.8 VOLTS: 120 2.5 7 POD #4 RACK 18 L6 -30R A 2.5 20.8 208 2.5 9 POD #4 RACK 19 L6 -30R B 20 2 2.5 20.8 PH: 3 2.5 11 POD #4 RACK 19 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 POD #4 RACK 20 L6 -30R A 20 2 2.5 20.8 BUS: AL 2.5 1 15 POD #4 RACK 20 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 POD #4 RACK 21 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 POD #4 RACK 21 L6 -30R A 2.5 20.8 MCB: 2.5 21 POD #4 RACK 22 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 POD #4 RACK 22 L6 -30R C 2.5 20.8 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0,0 DBL LUG 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2.5 2 POD #5 RACK 16 L6 -30R A 30 2 2.5 20.8 PANEL T.C.L. 2.5 4 POD #5 RACK 16 L6 -30R B 2.5 20.8 LOAD (kVA) 2.5 6 POD #5 RACK 18 L6 -30R C 30 2 2.5 20.8 RCPT #REF! 2.5 8 POD #5 RACK 18 L6 -30R A 2.5 20.8 LTG #REF! 2.5 10 POD #5 RACK 19 L6 -30R B 30 2 2.5 20.8 EQP 60.0 2.5 12 POD #5 RACK 19 L6 -30R C 2.5 20.8 HEAT #REFI 4 2.5 14 POD #5 RACK 20 L6 -30R A 30 2 2.5 20.8 2.5 16 POD #5 RACK 20 L6 -30R B 2.5 20.8 TOTAL #REFI 2.5 18 POD #5 RACK 21 L6 -30R C 30 2 2.5 20.8 2.5 20 POD #5 RACK 21 L6 -30R A 2.5 20.8 FEEDER T.C.L. 2.5 22 POD #5 RACK 22 L6 -30R B 30 2 2.5 20.8 LOAD (kVA) _ 2.5 24 POD #5 RACK 22 L6 -30R C 2.5 20.8 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 60.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REFI 42 C 0.0 0.0 AMPS #REFI #REF! #REF! 0.0 , #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REFI #REF! 0.0 #REF! LUGS C - #REF! #REF! #REF! #REF! 60.0 #REFI KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D - - -- A B - - -- - - -- CB Type: Square D #REF. #REF. 20.0 #REF! Remarks: Outlet Loads #REF! #REF 20.0 #REFI C _ #REF! #REFI 20.0 #REF! VELA Electric PANEL: • PDC 52 -BC3 -1 Sect.3 ... _ -THRU: Phase A ROOM: SOFTLAYER FEED LOADS FROM: STS 52 -BC3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 POD #6 RACK 16 L6 -30R A 20 2 2.5 20.8 2.5 3 POD #6 RACK 16 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 POD #6 RACK 18 L6 -30R C 20 2 2.5 20.8 VOLTS: 120 2.5 7 POD #6 RACK 18 L6 -30R A 2.5 20.8 208 2.5 9 POD #6 RACK 19 L6 -30R B 20 2 2.5 20.8 PH: 3 2.5 11 POD #6 RACK 19 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 POD #6 RACK 20 L6 -30R A 20 2 2.5 20.8 BUS: AL 2.5 15 POD #6 RACK 20 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 POD #6 RACK 21 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 POD #6 RACK 21 L6 -30R A 2.5 20.8 MCB: 2.5 21 POD #6 RACK 22 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 POD #6 RACK 22 L6 -30R C 2.5 20.8 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND. 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: I 1 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REF! 8 A 0.0 0.0 LTG #REFI 10 B 0.0 0.0 EQP 30.0 12 C 0.0 0.0 HEAT #REF! 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REFI 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REF! 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 30.0 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REFI #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REFI #REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REF! LUGS C " #REF! #REFI #REF! #REF! 30.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D - - - - -- - #REF! #REF! 10.0 #REF! A CB Type: Square D #REF! #REF! 10.0 #REF! B Remarks: Outlet Loads #REF! #REF! 10.0 #REF! C -._ -- - -- -------- - -_- - - • VECA Electric PANEL: PDC 52 ' _ _ -CB3 -1 Sect.1 ROOM: SOFTLAYER FEED -THRU: ,Phae A ' LOADS FROM: STS 52 -CB3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA !AMPS 2.5 1 POD #2 RACK 16 L6 -30R A 20 2 2.5 20.8 2.5 3 POD #2 RACK 16 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 POD #2 RACK 18 L6 -30R C 20 2 2.5 20.8 VOLTS: 120 2.5 7 POD #2 RACK 18 L6 -30R A 2.5 20.8 208 2.5 9 POD #2 RACK 19 L6 -30R B 20 2 2.5 20.8 PH: 3 2.5 11 POD #2 RACK 19 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 POD #2 RACK 20 L6 -30R A 20 2 2.5 20.8 BUS: AL 2.5 15 POD #2 RACK 20 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 POD #2 RACK 21 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 POD #2 RACK 21 L6 -30R A 2.5 20.8 MCB: 2.5 21 POD #2 RACK 22 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 POD #2 RACK 22 L6 -30R C 2.5 20.8 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2.5 2 POD #3 RACK 16 L6 -30R A 30 2 2.5 20.8 PANEL T.C.L. 2.5 4 POD #3 RACK 16 L6 -30R B 2.5 20.8 LOAD (kVA) 2.5 6 POD #3 RACK 18 L6 -30R C 30 2 2.5 20.8 RCPT #REF! 2.5 8 POD #3 RACK 18 L6 -30R A 2.5 20.8 LTG #REF! 2.5 10 POD #3 RACK 19 L6 -30R B 30 2 2.5 20.8 FOP 60.0 2.5 12 POD #3 RACK 19 L6 -30R C 2.5 20.8 HEAT #REF! 2.5 14 POD #3 RACK 20 L6 -30R A 30 2 2.5 20.8 2.5 16 POD #3 RACK 20 L6 -30R B 2.5 20.8 TOTAL #REF! 2.5 18 POD #3 RACK 21 L6 -30R C 30 2 2.5 20.8 2.5 20 POD #3 RACK 21 L6 -30R A 2.5 20.8 FEEDER T.C.L. 2.5 22 POD #3 RACK 22 L6 -30R B 30 2 2.5 20.8 LOAD (kVA) 2.5 24 POD #3 RACK 22 L6 -30R C 2.5 20.8 RCPT #REF! 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 60.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REFI #REF! 0.0 #REF! FEED A #REF! #REFI #REF! #REF! 0.0 #REF! THRU B #REF! #REF! #REF! #REF! 0.0 #REFI LUGS C " #REF! #REF! #REF! #REF! 60.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! Mfg/Type: Square D #REF! #REF! 20.0 #REF! A CB Type: Square D #REF! #REF! 20.0 #REF! B Remarks: Outlet Loads #REF! #REF! 20.0 #REF! C ii VECA Electric PANEL: PDC 52 -CB3 =1 Sect.2 3• ROOM: SOFTLAYER __ FEED -THRU: 'Phase A LOADS FROM; STS 52 -CB3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.5 1 POD #4 RACK 16 L6 -30R A 20 2 2.5 20.8 2.5 3 POD #4 RACK 16 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 POD #4 RACK 18 L6 -30R C 20 2 2.5 20.8 VOLTS: 120 2.5 7 1POD #4 RACK 18 L6 -30R A 2.5 20.8 208 2.5 9 POD #4 RACK 19 L6 -30R B 20 2 2.5 20.8 PH. 3 2.5 11 POD #4 RACK 19 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 POD #4 RACK 20 L6 -30R A 20 2 2.5 20.8 BUS: AL 2.5 15 POD #4 RACK 20 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 POD #4 RACK 21 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 POD #4 RACK 21 L6 -30R A 2.5 20.8 MCB: 2.5 21 POD #4 RACK 22 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 POD #4 RACK 22 L6 -30R C 2.5 20.8 FLUSH: 25 A 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 0.0 0.0 31 A 0.0 0.0 IG GRND 33 B 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 0.0 0.0 DBL LUG 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2.5 2 POD #5 RACK 16 L6 -30R A 30 2 2.5 20.8 PANEL T.C.L. 2.5 4 POD #5 RACK 16 L6 -30R B 2.5 20.8 LOAD (kVA) 2.5 6 POD #5 RACK 18 L6 -30R C 30 2 2.5 20.8 RCPT #REF! 2.5 8 POD #5 RACK 18 L6 -30R A 2.5 20.8 LTG #REF! 2.5 10 POD #5 RACK 19 L6 -30R B 30 2 2.5 20.8 EQP 60.0 2.5 12 POD #5 RACK 19 L6 -30R C 2.5 20.8 HEAT #REF! 2.5 14 POD #5 RACK 20 L6 -30R A 30 2 2.5 20.8 2.5 16 POD #5 RACK 20 L6 -30R B 2.5 20.8 TOTAL #REFI 2.5 18 POD #5 RACK 21 L6 -30R C 30 2 2.5 20.8 2.5 20 POD #5 RACK 21 L6 -30R A 2.5 20.8 FEEDER T.C.L. 2.5 22 POD #5 RACK 22 L6 -30R B 30 2 2.5 20.8 LOAD (kVA) 2.5 24 POD #5 RACK 22 L6 -30R C 2.5 20.8 RCPT #REF! 26 A 0.0 0.0 LTG #REF! 28 B 0.0 0.0 EQP 60.0 30 C 0.0 0.0 HEAT #REF! 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REFI 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REF! #REF! 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B " ' #REF! #REF! #REF! #REFI 0.0 #REF! LUGS C ' " #REF! #REF! #REF! #REF! 60.0 #REF! KVA/AMPS: #REFI #REF! #REF! #REF! #REF! #REFI _ Mfg/Type: Square D #REF! #REF! 20.0 #REF! A CB Type: Square D #REF! #REF! 20.0 #REF! B Remarks: Outlet Loads #REF! #REF! 20.0 #REF! C VECA Electric PANEL: ' PDC 52 -CB3 -1 Sect.3 Phase A ROOM: SOFTLAYER FEED -THRU: LOADS FROM: STS 52 -CB3 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA LAMPS KVA AMPS KVA AMPS _ _ _____ 2.5 1 POD #6 RACK 16 L6 -30R A 20 2 2.5 20.8 2.5 3 POD #6 RACK 16 L6 -30R B 2.5 20.8 AMP: 400 2.5 5 POD #6 RACK 18 L6 -30R C 20 2 2.5 20.8 VOLTS: 120 2.5 7 POD #6 RACK 18 L6 -30R A 2.5 20.8 208 2.5 9 POD #6 RACK 19 L6 -30R B 20 2 2.5 20.8 PH: 3 2.5 11 POD #6 RACK 19 L6 -30R C 2.5 20.8 WIRE: 4 2.5 13 POD #6 RACK 20 L6 -30R A 20 2 2.5 20.8 BUS: AL 2.5 15 POD #6 RACK 20 L6 -30R B 2.5 20.8 A.I.C.: 18K 2.5 17 POD #6 RACK 21 L6 -30R C 30 2 2.5 20.8 MLO: YES 2.5 19 POD #6 RACK 21 L6 -30R A 2.5 20.8 MCB: 2.5 21 POD #6 RACK 22 L6 -30R B 30 2 2.5 20.8 3R: 2.5 23 POD #6 RACK 22 L6 -30R C 2.5 20.8 FLUSH: 25 A 30 2 0.0 0.0 SURF: YES 27 B 0.0 0.0 29 C 30 2 0.0 0.0 31 A 0.0 0.0 IG GRND. 33 B 30 2 0.0 0.0 200% N: 35 C 0.0 0.0 FD THRU NO 37 A 30 2 0.0 0.0 DBL LUG 39 B 0.0 0.0 TOP: YES 41 C 0.0 0.0 BTM: 2 A 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT #REFI 8 A 0.0 0.0 LTG #REF! 10 B 0.0 0.0 EQP 30.0 12 C 0.0 0.0 HEAT #REFI 14 A 0.0 0.0 16 B 0.0 0.0 TOTAL #REF! i 18 C 0.0 0.0 20 A 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT #REFI 26 A 0.0 0.0 LTG #REFI 28 B 0.0 0.0 EQP 30.0 30 C 0.0 0.0 HEAT #REFI 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL #REF! 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA #REF! 42 C 0.0 0.0 AMPS #REF! #REF! #REFI 0.0 #REF! FEED A #REF! #REF! #REF! #REF! 0.0 #REF! THRU B #REF! #REFI #REF! *REF! 0.0 #REFI LUGS C ' " #REF! #REF! #REF! #REF! 30.0 #REF! KVA/AMPS: #REF! #REF! #REF! #REF! #REF! #REF! - - - - -- 1 Mfg/Type: Square D --- - - - #REFI #REF! 10.0 #REF! A CB Type: Square D #REF! #REF! 10.0 #REF! B Remarks: Outlet Loads - - - - -- - -- - -- ------ #REF! #REF! 10.0 #REF! C - - -- • • PE }, ,!* S PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL09 -0677 DATE: 10 -29 -09 PROJECT NAME: SOFTLAYER SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal _ Response to Correction Letter # _ Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 0A,vi 1\ uilding DWs on Public Works Fire Prevention Structural Planning Division Permit Coordinator a DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-03-09 Complete Comments: [K Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: DUE DATE: 12-01-09 Approved with Conditions g Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Untitled Page • Page 1 of 3 Electrical Contractor A business licensed by LQi to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company VECA ELECTRIC CO INC 2064365200 5614 7TH AVE S PO BOX 80467 SEATTLE WA 98108 KING Corporation UBI No. 601190731 Status ACTIVE License No. VECAECI542MU License Type ELECTRICAL CONTRACTOR Effective Date 7/31/1946 Expiration Date 10/31/2011 Suspend Date Specialty 1 GENERAL Specialty 2 UNUSED MASTER ELECTRICIAN INFORMATION License CONTIK`965D6 Name CONTI, KEITH Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS Cancel Date 01/01/1980 Bond Amount ALLEN, RON AGENT 01/01/1980 929407110 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 WESTERN SURETY CO 929407110 01/06/2007 Cancelled ncelled $4,000.00 01/06/2007 6 TRAVELERS CAS it SURETY CO 081510352049701 /06/2001 Until Cancelled 01/06/2007 $4,000.0001 /05/2001 5 UNITED PACIFIC U2800434 01/06/1998 Until Cancelled 01 /06/2001 $4,000.0001 /05/2001 https://fortress.wa.gov/lni/bbip/Detail.aspx 11/09/2009 DRAWING INDEX SHEET DESCRIPTION E0.00 COVER SHEET E0.01 LEGEND E0.02 ABREVIATIONS E1.11 1ST FLR PARTIAL POWER E2.11 2nd FLR PARTIAL POWER E2.11a 2nd FLR POD POWER E2.21 2nd FLR PARTIAL LIGHTING E2.41 2nd FLR PARTIAL COMM E2.42 2nd FLR COMM INTERCONNECT— E5.11 ONELINE DIAGRAM PHASE 1 10 11 12 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. Plan review :I +royal is Approval of co the violation of any a of approved Field Copy and By hl . /c • 1`(- • 11P to ►i I oro ►i' s.1qf'$ TS and Lut 13 not 1 1 r: 77 f I I. /7- —o 7 City Of ltt ING ELO 0 (o77 NOV 0 5 2009 RECEIVE() OCT 292009 ?ERMIT CEN3EB REVIEWED FOR COMPLIANCE WITH NFPA - NEC City of Tukwila BUILDING DIVISION Q' IA OID v m z r 0 0. 0 v wm o z O T 41-• O T C O L m O .Id C — SOT C O O 1A N. at oQ CS" o the 0TN I- N CO CO I- • N ' co co N o NN LL m U)I — LJ Co) nt c) N O O O co ,d. w 1 C m . ® • ��'N > WmcD Z Q c0 '4 " N m m .r m J O 4-' O O I �� N ' A N N V TNII� IC iil i u) m ao F Z Q co ▪ CO ig T- WN W Vaco 0 O > I t a� 'ig N 8 !f o II- to � wT w ▪ (A Q In W Et c� m W c) DRAWING INDEX E 0 • 0 o v 0 >+ m .0 0 0 ISSUED / REVISED DATE PERMIT SET 10/12/09 PERMIT SET REV. 10/15/09 E0.00 REFERENCE SYMBOLS LEGEND SYMBOLS LEGEND - LIGHTING SYMBOLS LEGEND - POWER SYMBOLS LEGEND - POWER SYMBOLS LEGEND - COMMUNICATION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL PLAN DIAGRAM PLAN DIAGRAM PLAN DIAGRAM - PLAN DIAGRAM DESCRIPTION A DETAIL SYMBOL A- IDENTIFYING NUMBER B- SHEET WHERE DETAIL IS SHOWN ELEVATION OR SECTION SYMBOL A- IDENTIFYING NUMBER B -SHEET WHERE DETAIL IS SHOWN NORTH ARROW EQUIPMENT IDENTIFICATION SYMBOL. REFER TO EQUIPMENT SCHEDULE. REFERENCE NOTE TAG SYMBOL A - NOTE NUMBER LIGHTING FIXTURE IDENTIFICATION SYMBOL. REFER TO LIGHTING FIXTURE SCHEDULE. POWER RACEWAY/CABLE IDENTIFICATION SYMBOL REVISION SYMBOL REFERENCE PHOTO NUMBER & DIRECTION CONTROL RACEWAY IDENTIFICATION ,OA\ � —I� — I I— LIGHTING FIXTURE ADJACENT NUMBER INDICATES CIRCUIT GROUPING LOWER CASE LETTER INDICATES SWITCHING GROUP ADJACENT TO FIXTURE INDICATES NIGHT LIGHT SURFACE- MOUNTED FLUORESCENT LIGHTING FIXTURE WITH ' JUNCTION BOX - TYPE AS NOTED, SIZE AS SHOWN RECESS- MOUNTED FLUORESCENT LIGHTING FIXTURE WITH JUNCTION BOX - TYPE AS NOTED, SIZE AS SHOWN RECESS- MOUNTED, LAY -IN, FLUORESCENT LIGHTING FIXTURE (TROFFER) - TYPE AS NOTED, SIZE AS SHOWN ) SHADING INDICATES EGRESS LUMINAIRE ON EMERGENCY CIRCUIT OR WITH BATTERY BACKUP BALLAST (TYPICAL) PENDANT- MOUNTED FLUORESCENT LIGHTING FIXTURE - TYPE AS NOTED, SIZE AS SHOWN (CEILING MOUNTED J -BOX SHOWN) WA LL- MOUNTED FLUORESCENT LIGHTING FIXTURE - TYPE AS NOTED, SIZE AS SHOWN RECESSED, WALL- MOUNTED FLUORESCENT LIGHTING FIXTURE WITH JUNCTION BOX TYPE AS NOTED STRIP FLUORESCENT LIGHTING FIXTURE - TYPE AS NOTED STRIP FLUORESCENT LIGHTING FIXTURE ON EMERGENCY CIRCUIT - TYPE AS NOTED STAGGERED STRIP FLUORESCENT FIXTURE -TYPE AS NOTED WALL- MOUNTED LIGHTING FIXTURE -TYPE AS NOTED WALL- MOUNTED LIGHTING FIXTURE ON EMERGENCY CIRCUIT - TYPE AS NOTED WALL WASH FIXTURE - TYPE AS NOTED PENDANT- MOUNTED LIGHTING FIXTURE -TYPE AS NOTED CEILING - MOUNTED LIGHTING FIXTURE - TYPE AS NOTED CEILING- MOUNTED LIGHTING FIXTURE ON EMERGENCY CIRCUIT - TYPE AS NOTED DIRECTIONAL LIGHTING FIXTURE - TYPE AS NOTED DIRECTIONAL LIGHTING FIXTURE - TYPE AS NOTED INDICATING LIGHT - TYPE AS NOTED A- AMBER; B -BLUE; G- GREEN; R -RED; W- WHITE TRACK LIGHT - TYPE AS NOTED NUMBER OF HEADS AS SHOWN FLEXIBLE TRACK LIGHT - TYPE AS NOTED NUMBER OF HEADS AS SHOWN RECESSED TRACK LIGHT - TYPE AS NOTED NUMBER OF HEADS AS SHOWN ILLUMINATED EXIT SIGN - SINGLE FACE ARROW INDICATES DIRECTION OF EGRESS ILLUMINATED EXIT SIGN - DUAL FACE WALL MOUNTED ILLUMINATED EXIT SIGN - SINGLE FACE WALL MOUNTED SELF CONTAINED EMERGENCY LIGHT COMBINATION SELF CONTAINED EMERGENCY WALLPACK/EXIT LIGHT POLE- MOUNTED LIGHTING FIXTURE - TYPE AS NOTED NUMBER OF FIXTURES AS SHOWN EXTERIOR HUMAN SCALE LUMINAIRE, TYPE AS NOTED EXTERIOR LANDSCAPE LUMINAIRE, TYPE AS NOTED EXTERIOR STEP LIGHTING FIXTURE -TYPE AS NO TED PHOTOELECTRIC CONTROL - CEILING MOUNTED ADJACENT LEI IER P INDICATES PENDANT MOUNTED A DJACENT LETTER W INDICATES WALL MOUNTED U - ULTRASONIC - IR PASSIVE INFRARED DT - DUAL TECHNOLOGY ILLUMINATION CONTROL STATION WITH DESIGNATION CONTACTOR SUBSCRIPT INDICATES NUMBER OF POLES CONTACT NORMALLY OPEN NUMBER INDICATES REFERENCE NORMALLY CLOSED LEI I ER INDICATES FUNCTION RELAY COIL CR- CONTROL RELAY; TD -TIME DELAY RELAY; UV- UNDERVOLTAGE RELAY; M -MOTOR CONTACTOR;)- TIME CLOCK POWER SUPPLY -- -- + - 101 1 p ®, ►1 ❑� CB + - - -- 1 --o (,ST Q 1 30 /3 La......., UNDERFLOOR DUCT MET CO COMBINATION STARTER HP RATED, 3 -POLE, NEMA SIZE 1 MINIMUM TED OTHERWISE - OVERCURRENT PROTECTION SIZED BY EQUIPMENT MANUFACTURER OR AS NOTED STARTER MA SIZE 1 MINIMUM UNLESS NOTED OTHERWISE DISCONNECT SWITCH LESS NOTED ' OTHERWISE - OVERCURRENT + _p SIZED BY EQUIPMENT MANUFACTURER OR AS - CIRCUIT ER INDICATES TRIP SETTING AND NUMBER OF POLES INDICATES CURRENT LIMITING INDICATES SHUNT TRIP TRA POLE-MOUNTED TRANSFORMER SUBSCRIPT NUMBERS INDICATE: I ER - NUMBER OF TRANSFORMERS SECOND NUMBER - TRANSFORMER kVA RATING NUMBER - NUMBER OF PHASES PAD TRANSFORMER DEL WYE OPEN GEC MOT ;TION - SEE SCHEDULE FOR MOTOR DATA MA( 'STARTER 480 ►, 4 -WIRE SURFACE MOUNTED PANELBOARD 208 �, 4 -WIRE, SURFACE MOUNTED PANELBOARD 208 4 -WIRE, RECESS WALL MOUNTED PANELBOARD EQUIPMENT CABINET - SURFACE MOUNT, TYPE AS NOTED BATTERY EQUIPMENT CONNECTION POWER POLE PULLBOX HANDHOLE WITH DESIGNATION MANHOLE WITH DESIGNATION PUSHBUTTON P - INDICATES WITH PILOT LIGHT EQUIPMENT EMERGENCY POWER OFF (EPO) SWITCH MICROPROCESSOR CONTROLLED MONITOR REFER TO SPECIFICATIONS FOR METERING VALUES AND PROTECTIVE FUNCTIONS CURRENT TRANSFORMER QUANTITY AND RATIO AS INDICATED BREAKER WITH EXTERNAL GROUND FAULT RELAY AND CT CIRCUIT BREAKER WITH GROUND FAULT PROTECTION NUMBER INDICATES TRIP SLI IING AND NUMBER OF POLES MOTOR- OPERATED CIRCUIT BREAKER NUMBER INDICATES TRIP Stl ZING AND NUMBER OF POLES SWITCH WITH EXTERNAL GROUND FAULT RELAY AND CT POTENTIAL TRANSFORMER QUANTITY AND VOLTAGE RATING AS INDICATED SURGE ARRESTORS FUSE WITH RATING MOTOR THERMAL OVERLOADS - (3) UNLESS OTHERWISE NOTED 2- POSITION SELECTOR SWITCH ........... ........_ - ® 14 a 0 'i? %a- le � .. el QI 3- POSITION SELECTOR SWITCH HAND- OFF - AUTOMATIC ON-OFF SELECTOR SWITCH 2- CIRCUIT PUSHBUTTON PUSHBUTTON SWITCH CIRCUIT CLOSING MOMENTARY CONTACT CIRCUIT OPENING HIGH VOLTAGE CABLE TERMINATOR SEPARABLE CONNECTOR DRAWOUT AC TYPE POWER CIRCUIT BREAKER AIR TERMINATOR LIGHTNING ARRESTORS NEUTRAL GROUNDING RESISTOR INDICATING INSTRUMENT _ _ AM- AMMETER VM VOLTMETER; FM FREQUENCY METER; kVAR- KILOVAR METER; kWH- KILOWATT HOUR METER; kVAR /D- KILOWATT HOUR DEMAND METER INSTRUMENT SWITCH AS- AMMETER SWITCH; VS- VOLTMETER SWITCH; SS- SYNCHRONIZING SWITCH; SV- SUPERVISORY (LOCAL - REMOTE) SWITCH MOV SURGE PROTECTION RESISTOR SOLENOID VALVE MOTOR- OPERATED VALVE THERMOSTAT TERMINAL BLOCK - NUMBER INDICATES REFERENCE RECEPTACLE OUTLET: SUBSCRIPT NUMBER INDICATES CIRCUIT GROUPING SUBSCRIPT LEI IER INDICATES: XP EXPLOSION PROOF GFI GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF IG ISOLATED GROUND C CEILING MOUNTED S SURFACE MOUNTED GROUNDING -TYPE SINGLE RECEPTACLE GROUNDING -TYPE DUPLEX RECEPTACLE GROUNDING -TYPE DOUBLE DUPLEX RECEPTACLE SPLIT -WIRED GROUNDING -TYPE DUPLEX RECEPTACLE SPECIAL PURPOSE RECEPTACLE - TYPE AS NOTED FLUSH FLOOR BOX WITH HINGED DEVICE COVER FLUSH FLOOR BOX WITH DEVICES AS NOTED PEDESTAL- MOUNTED DEVICES ON FLOOR BOX OR FLOOR DUCT FLUSH FLOOR COUPLING WITH RECEPTACLE FLUSH FLOOR COUPLING WITH SINGLE PEDESTAL RECEPTACLE • ® b ® QQ Qs F® ® 0 4 0.4 ® 'fl Ic ® 0 I{9 ®Q► K -1 P W A ® MICROPHONE OUTLET SPEAKER: S- SECURITY, F -FIRE ALARM LOWER -CASE LEI IER INDICATES SWITCHING GROUP SPEAKER - CEILING SURFACE - MOUNTED SPEAKER - CEILING RECESS- MOUNTED SPEAKER - WALL SURFACE- MOUNTED SPEAKER - WALL RECESS- MOUNTED AUXILIARY INPUT JACK VOLUME CONTROL AUDIO /VIDEO SYSTEM JACK COMPUTER /DATA OUTLET FLUSH FLOOR COUPLING WITH PEDESTAL TELEPHONE OUTLET COMBINATION VOICE DATA OUTLET SUBSCRIPTS INDICATE: / A - COMPLIES WITH A.D.A. D -DESK - MOUNTED P - PAY PHONE W - WALL - MOUNTED INTERCOM STATION - SUBSCRIPT INDICATES: D - DESK - MOUNTED STATION OUTLET M - MASTER STATION W - WALL - MOUNTED OUTLET INTERCOM SWITCH TELEPHONE OUTLET - SUBSCRIPT INDICATES: A - COMPLIES WITH A.D.A. D - DESK - MOUNTED P - PAY PHONE W - WALL - MOUNTED TELEVISION OUTLET CLOCK - WALL- MOUNTED CLOCK - CEILING - MOUNTED, DOUBLE -FACED CLOCK AND SPEAKER COMBINATION INTERCOM MASTER STATION INTERCOM REMOTE STATION ANNUNCIATOR - TYPE AS NOTED I 6a,b B A a A - -'-- -0 ! o-- • BUILDING NORTH B Np�,T h' A OA 0 /A\ O 0---0 0- - a i Q- ■ - -< '-' .-wHI' -Lk ® AM AS M � OT o >- ' 0- 1A 2 _ n o 1 -25 -1 n 0 M � = j 'O O) Q O 1 0 - - FID- ' r ' ITC - A 0 ® SYMBOLS LEGEND - GENERAL SYMBOL PLAN DIAGRAM DESCRIPTION -I -Ail- - - CONDUCTORS - CONNECTED CONDUCTORS - NOT CONNECTED CONDUIT - CONCEALED IN WALL OR CEILING IN FINISHED AREAS, EXPOSED IN UNFINISHED AREAS - CONDUIT ROUTED UNDERFLOOR OR UNDERGROUND GROUND WIRE ,- 1 IcM 1 �_ — c — � ICR ( ® 1- + HH MH FIJI ® PB HH -1 MH -1 P SYMBOLS LEGEND - FIRE ALARM la n al ,S r SYMBOL DESCRIPTION LOW- VOLTAGE WIRING PLAN DIAGRAM o, • C 1 I r P M al o 110 h °.p 110 F ' M [4 , o o,p I F I FIRE ALARM HORN STROBE COMBINATION - WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA. ADJACENT LETTER "C" DENOTED CEILING MOUNTED. FIRE ALARM SPRINKLER BELL FIRE ALARM MINI -HORN - WALL MOUNTED FIRE ALARM STROBE - WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA FIRE ALARM BELL STROBE COMBINATION -WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA FIRE ALARM PULL STATION FIRE ALARM SYSTEM CONTROL PANEL ESR - ELEVATOR STATUS /RECALL FAC - FIRE ALARM COMMUNICATOR FCP - FIRE ALARM CONTROL PANEL FSA - FIRE SYSTEM ANNUNCIATOR HCP - HALON CONTROL PANEL HVA - HVAC OR EXHAUST STAIRWELL PRESSURIZATION FIRE ALARM ANNUNCIATOR FIRE ALARM RELAY FIRE FIGHTER PHONE JACK FIRE ALARM SPRINKLER TAMPER SWITCH FIRE ALARM SPRINKLER FLOW SWITCH FIRE ALARM SPRINKLER SUPERVISORY SWITCH FIRE ALARM SPRINKLER LOW PRESSURE SWITCH FIRE ALARM DUCT SMOKE DETECTOR - WITH TUBE FIRE ALARM SMOKE DETECTOR - CEILING MOUNTED FLAME DETECTOR ,. r,. --.,.. FIRE ALARM CHIME FIRE ALARM HEAT DETECTOR - CEILING MOUNTED ALARM BUZZER A- ALARM; F -FIRE; S- SECURITY FIRE /SMOKE DAMPER GAS DETECTOR .� ® 4-6 ' SURFACE METAL RACEWAY (SHOWN WITH JUNCTION BOX) FIRST NUMBER INDICATES NUMBER OF RECEPTACLES SECOND NUMBER INDICATES SPACING OF RECEPTACLES IN INCHES n Al Of ®i FO �° i 0- 1:1 ,O: ° o Pc P P °c DT S1 ICS -1 I/ 4 / / /` /, /�, / //, EXISTING TO BE REMOVED (CROSS HATCHED) HEAVY LINEWEIGHT INDICATES NEW WORK LIGHT LINEWEIGHT INDICATES EXISTING INFORMATION CONDUIT OR CABLE DOWN CONDUIT OR CABLE UP CONDUIT CAPPED ] $sa Op ] FLEXIBLE CONDUIT HOME RUN - NUMBER OF CONDUCTORS AS INDICATED SMALL HASH MARKS INDICATE PHASE CONDUCTORS LARGER HASH MARKS INDICATES NEUTRAL BACKSLASH INDICATES GROUND WIRE BACKSLASH WITH DOT INDICATES ISOLATED GROUND ALL UNMARKED CONDUIT RUNS ARE 1/2" CONDUIT WITH 2 #12 & 1 #12 GND, UNLESS NOTED OTHERWISE: SINGLE -POLE SWITCH SWITCH - LOWER CASE LETTER INDICATES SWITCHING GROUP SUBSCRIPT INDICATES: 2 2 -POLE 3 3 -WAY 4 4 -WAY D DIMMER WP WEATHERPROOF LV LOW- VOLTAGE K KEYED OS OCCUPANCY SENSOR T TIMER HOA HAND -OFF -AUTO JUNCTION BOX 200/5 ill 6 Q 1 b Q 1 480V '-I . O G 1000/3 100/3 6 ST 0 120V H L HII 30 -+1 1I-- e a I TCP I F� ❑ C Ts 0 • • • <> F 1 C • • • SYMBOLS LEGEND - SECURITY SYMBOL DESCRIPTION PLAN DIAGRA oa WP PTZ L___a ® © KP cR RX s� CCTV CAMERA - FIXED WP INDICATES WEATHER PROOF CCTV CAMERA -PAN TILT ZOOM , SECURITY SYSTEM MOTION SENSOR SECURITY SYSTEM DOOR /WINDOW CONTACT ACCESS CONTROL KEYPAD ACCESS CONTROL CARD READER ACCESS CONTROL REQUEST TO EXIT SECURITY SYSTEM DOOR LOCK 02 0 F FOI O FAQ/ IFSDI 0 ----- 0? e FQQ I OO c 0 SYMBOLS LEGEND - GROUNDING_ TC PS cR SYMBOL DESCRIPTION PLAN DIAGRAM T b GROUND CONNECTION GROUND ROD GROUND WELL FIRE ALARM TERMINAL CABINET a REVIEWED J COMPLIANCE NFPA 7 - N TC I 10 11 12 PROJECT GENERAL NOTES: 1. SYMBOLS SHOWN IN THE LEGEND ARE TYPICAL. NOT ALL SYMBOLS MAY APPLY TO THIS PROJECT. 2. PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION. MATERIALS AND WORKMANSHIP SHALL FULLY COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, THE INTERNATIONAL BUILDING CODE, AND THE LAWS AND REGULATIONS OF THE STATE OF WASHINGTON. LO 1-- 0 (97 ' 13 NOV OR E WE H City of Tukwila BUILDING DIVISION RECEIVED OCT 2 9 2009 PERMIT CENTER Q' z 0 U) J ist W F z W N 0 0 4 N N rn v CI 0 W H PERMIT SET LEGEND Z c 0 PERMIT SET REV. ; O O O L C � o E e as w �.., a o co > Z O > OC)O LJ OG a) o o ON al 0 • O � cc 0 2 - CO ai N W CD wm O L +•' O Z Cy t6 N N oa) o (A u_ I- 2 r .- N N O CL. in C l) Cl) N 0 O r O co .4 rn N c m 0 z 0) c c CO m - `4" > CO Q " r M � N .- a) . CO u_ o o -O C•1 C N W CO CD C c>s o OD CD .c Q LO cn LO M E_ Cl) ISSUED / REVISED DATE E0.07 0 c) I- 0 w a 10/12/09 10/15/09 NTERGATE EAST CAMPUS SOFTLAYER 206 623 4625 CALLISON woo• eges•MMM 1.966 Z8Z 90Z d 00L8 I.8Z 90Z 1 1.Z1.9 YM `elileeS JOOld utanod . pnl8 Ieuol4ewe ul el!M>Inl �OZZ6 NO11VZIOd21O0 A38VS :213NMO £Y- ZS -d9M ZY - -dW A3YN A8311Y8 BATTERY RACK )13Y11 AMMO BATTERY RACK SfS 52 STS 52 - AC2 1NO11d £B - Z5 sdn Z3Y- ZS -S1S £Y3- ZS -SJ.S ZYB- ZS -SIS ZBY- ZS -SIS STS- 52 -AB3 - 52 -BA3 UPS 52 -A3 FRONT UPS -52 -B2 FRONT UPS -52 -A2 FRONT £B -ZS -dell ZB- ZS -dBM ::: • ER ER Nj .wanat �.,k,. ...tiv • €rw �ai.0 >tn.s...k.x....Er.�c•. .r:•�+x�. ve.. 0 I w woa•eoan•MnnM 9090 (90Z) xd 00Z9 (90Z) qd 901.96 VM `eltteeS 41noS '0AV 41L ti699 0 14 30 13 83OA :INV1111SNO0 I: ' 1 N) U J m k� woo•U0SIIIe3 - MMM 9Z9t EZ9 90Z d 9j79b £39 90Z 1 £17E3 1.96 uo16ulyseM `aifleaS 00t7Z# amend 11411d OZV I. NOSI'11d0 w- NOSI11Y3 N0U.33NNO3 IO1YN3N39 NOI133NNO3 a01Y213N39 al CD N N0L133NNO3 NOIYI3N39 891.86 bM `BI!Molnl eoeld y1OZ I- 'S 99CE SfldINV3 1SV3 31`1OI21NI 2I3AV11 :OS ZO-ZSpaS 2I31N33 viva _ A3SVS # 103fO id NO.133NNO3 1YI3N39 U w 0 0 w rn rn 0 0 N to 0 0 w a_ CC w z u was °' 0 cv o CC W a Po • a= 1 a V T ull L J co .PAIR WOO'Aeges MMM 1966 Z8Z 90Z d Ooze 68Z 90Z 1 6Z69 yM `el }HeeS JoeIA I Jno,d leuol ;euae ;u l 8 10 0 01 6 OZZ 6 NOIJ.V OdUOO AaBVB :Z13NMO } k�•»v N VI 1 N 1 N 1 N nv:.: n•.::nu 0 N O N 0 N M g Za_ I co xx 5 G w c4 U = I 17 <L _m m - 0 0,_ O I m Li, I o t Mk0. -> CC LO WOO'eO0A'MMM SOSO-E9L (9o) Xd OOZS-9cv (90Z) 4d 80686 yM 'ewes LIMOS •eny LOL jroler o a3 :1NVIVISNO0 I A i W OO' UOSI I IeO'MMM 9Z9ti EZ9 90Z J 9p9ip EZ9 90Z J. E'VEZ-60 686 UO 6UI4seM `0111809 001rZ# enueAV LIMA ()Z$ I NO8117V3 W b o w cc m £80 aad /SIS NOSI11V3 Z83 aad Z38 aad Z83 aad ZO8 aad • .a:<„xaaK„xx ^ } >.H.:a > O IX En eL m N U) Z38 SiS aUZ � zo V)Z Q CO 99196 dM 'ellnn)lnl eoeld UM. 'S 99EE sndwVO ISV3 21V0t131NI U 3AV L OS ZO -Z5o ®S UI311H33 VIVO A]BYS # 1O3rO21d L38 SiS I CL ci M CS' I'7v £ 00d £ee aad £8V aad £de aad £38 aad /SiS L38 aad L83 aad m W Q 0 0 w W re 0 W D N al co 00 to O 0 vn ..v. :,,.n nt •. • 1 m� w., u .,vn . » n,,,:•.,.,,•.,,nxx,, , ..xx ..:x,xxE,4.. \ N m 0 :,•i };. ;:. 2 `.,...,., „..• •• a;; a .., ;; a •,. ; ..»•. v... v..:x, » „v.,:»,,,,,.n,.: »:x,v. vx .: :.,,x,,,,,:,,v,: :.»,,,,, ....... , »:..: .::•::.a:�,.:.. ,. ?: ti ,.... M.,... y : v .: v ..,.. x,• nx: x .::.::::..:.::. ::.:....w,x,xx,:M:.n:nv.,,:::,, :,:.: ::., ..:. » .�,,• :...,�,.�.. .. ,::.:. •„ ....n:.:. �n.v:::n .,�» ».a:: »,rv;.p. \;;} .v:... ;,b ». »,v.:v,,.,v.v:.:v. »» v.v.,v.v;.. 5. ;.. ...::...... ,.. :a r.,...•.. »;.,.n;,.a...,. s,.: ,...., ., ».... �.,., .a,..,...i, ,.a r.: +�.,. s,....,..,:.;: MVns.». a+,..,...,... o,:,., zwr »,a,>w>»�.ww>r>.mw:,,.a�\i,... . m> u>.« arxwazwa.. nu,. 4,. k; xS.. � ::as:a::o:;.vu:.::;zuz:E:,.:. rr. r...,,.,,,,.. v.,, a.,,.,,.,,. a<,., x.;. t4....,.\ a\• w:•. ww.....+. rner.• x•> mrra• w. vavaaa;>;. awa.,>.x smwrrrr. m< a a.,...,er...,,,,,t.,,.:,,.,.,,. k:..,.:..,..,aa:;.\ . E xo z la cn n » »» , . »»vmwn »,» , ,» »,,,v.,vn,,,. x ».» »,», » »,x,»», »»»wn »vxnw:rn„ �w v.•Ft» G »v':: i'. 4�: v \ \tiv \.v \vv:'v4�ttij \ \4s4ti1 \s »•^ , h . „•., 'n„,xw, »vn »,,, v»,,, »,,;n,»», , ,v m>> , - - ,vm�, »x v •. nv , �s� . • IQ.,v • . .n, � Me .{tn .... .... .... .... .... ..... .... ... .. .... .... aa x .,. xw .ww uuaazwua�u.xxa. .: �tu J j7t{ , , r, . , , wuwuu +aazwuza»z zuava wzwzwvzv,.. w ,n a �:�i::.vv..:.. C »» •„v .w.wr>w4zx<•>.>.wazq>.a . xazwaww.zw rzv>.aawu,.ur>xuaraax >m>rw�a,.az,zaa:,a>:w. r. zwarz+z^a ,.�wwvz wuk, K^a'� ay2. N II 00 ® boa ® 300. a ®10a ®30a a ®boa ® 3a a 0 boa ® 30. a 0 * boa ® 30a a boa ® 30a a (Oa 30a a ®10a ® 30a a * ®30a ®b 30 a a *boa 30a *boa 300. ®boa ®30a a *boa ®30a a *ea * a *boa ®300. a 330a ' ®a a boa ®30a a coo. ® 300. a ®boa ®300. a f •. 30a ®30a a 330a ® 30a a boa ®30a a ®boa ® 30a a boa ® 30a Roo. * boa ®30a a b 0a ® 30a a ®b0a ® 30a a * b0a ®30a a ®b0a ®30a a *boa ®30a *ea ®30a a boa a0a *boa ®30a a * goo. ®300. a boa ® 30 a a ®300. ®b0a ®30a a ®boa ® 30a a ®boa ®30a a • * boa ®300. a * goo. ® 30a a ®boa * 30a a ®b0a ®30a a *boa ®30a a boa ®a 30a - . ® 30 a a * boa ®30a a ®boa ®a • boa ®30a a *b oa ® 30a a *boa *(3 0o, a *pa ®300. ®boa ®300. *boa ® 300. a 0 *ea ®30a a *boa ® tea • boa ®30a a *boa ®30a a ®b0a 300. a 330a ®30a a 3 ® 30a a b ® 30a a b ® 30 0 a .'30a ®30a a ®b ®30a a 30a ®300 a *ea 3 a 0a ®b 0a ®30a a *ea ®30a a boa ®30a a *boa ®30a *ea ®30a a ®boa ® 30a a *ea ® 30. a 0 Coo, 3a a 0 ®300. CO ®30a ®boa *g oo. a coo. ®30a a * ®30a a ®b 30a ®10a ® 30a a * goo. ®30a a ®b ®30a a *boa ®300. 30a ®30a a ®boa ®30a a ®boa ®30a a *ea ®30a a c oax ®30a a * boa ® 30a *boa ®30a a ®10a ®30a a *boa ®30a a ® boa ® 300. a *boa ®boa ®30a a boa ®300. a * goo. ® 30a a q boa ®300 a *boa ® 30a a *boa ® 30a a *boa 0 *3a a ®boa � 30a a coo. ® 300 a 30a ® 30 a 0 ® b0a ®300 * boa 3 a 0a ®boa ®30a a ®boa La 300. a ® boa ®b0a ®30a ® 30a a a 0•. Oa %Oa Oa • 10 11 12 13 SCALE 1/4 " =1' 4 ELOgivis- 04;77 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 0 5 2009 City of •Tukwila BUILDING DIVISION RECEIVED 0CT292009 PERMIT CENTER z 0 N 1 J V W Z C Q C �•-' N I - O • E to N m co ® c . co Z _ w O 3oQ • ad 0 • 7 . W m o ' .— Z N l0 O M r L V) g CA W 0 Z ig Q !0 _ W N W V O- co ✓ 0 4 !-W l W ▪ w Y W � O p I-- co Q ) CO (9 14 W r‘ or) m W of) 1- 4 ~ Z o t - E o 10 0 h co co • r 00 00 .0 NNO CO mm 00 N N3 H U. N T- O O r Q co O N � C O 0 3 0 c c co 0 0 m td N 0 > coco Z< co ‘ 0 ® _ co c0 N — m co m W CO CO !� . 0»+00 4 N ® N C•1 U 3 SECOND FLOOR POD POWER ISSUED / REVISED DATE PERMIT SET 10/12/09 10/15/09 E2.11a 'PA19 WO0 0ges'MMM 1966 Z8Z 90Z d 001.8 69Z 90Z J. 1 Z19 VM 'e1U Joold 4o.inod euoi ;euie ;ui e11N►)Inl 60ZZ6 NOI.IVUOd11O3 Aa8VS :213NMO Y ® \ 00 U n n tgr1 €,, • ) ` N • ....»,.,,,.,... ,»,......».» .. ................ k..v .»,,.»..,,..».. »»»»»,»,,. .,,..».».,,,.,, w,t LO ME ME ME rimmue MEI ME NM 0 0 ME s I II EM IIE 11111111111111111 mum 11111P mol INN =1 Z3e JUId Z80 aad Z38 aad ZOO aid L38 aad aad Z80 S1S Z38 SIS «,vr.,..,..,.x,. r.,xxr. rnt ^:i ^ ,,,,..,. v., tr..,. w .v.•nwnrxtr,..tv..,tn.uv..vv.$' k„.# 7 IED= LOG SIS CVO SIS £eb aad £V8 aad £8`d aad £V8 aad £08 aad /SIS LOG aad lea aad ia P O Z U H- 0 W � Z U Z 0 0 U H cn i„. 0 O D w 0 U — w L11 WOO'e09A'MMM 9090 - £9L (906 xx 00Z9 (906 4d 80 686 VM 'eli}eeS limos 'eAV'PL t'699 3 14 90 13 ROeA :14V1'Inswo3 • aa W00'u0SllleO'MMM 9Z917 £Z9 90Z d 91791' £Z9 90Z 1 £V£Z-60686 uo; 'ei;;BeS 00•'Z# enueAV LIMA OZVI NOS19'11,3 NOSI'I'Itl3 LO " ,,,,,, KMw., .,,,,.,, »,,,.,,vx,.,,,.,,,,.,.x LO 891.86 VM 'e11M�n1 eOeid 1 .110Z1. 'S 996£ SndwVO 1SV3 31V01J31N1 UI]AV J OS ZO -Z93011 U1]1■]3 f/.LV® ASBYS . �aay.:vw W. u^• �a «av:aw.:a� ^;<aocawxa w . # loaf o Id • (../.) �. Gv .f....., • W a 0 0 0 N IA T T 0 0 T T s cc LU ku CM I- LIJ } 4 :.XNNNVN•r. ti v ' 4. } 1 1 LU vr�a..t.....e�a:orxaun f.Fa* i, EE 3 .' • WOO•Aeges•MMM 1.966 ZBZ 90Z d 00L9 68Z 90Z 1 6Z 69 VM 'e111B Jooid 4f.inod 'PAIR leuoneuae ;ul ellM 60ZZ6 NOIJ O3 A3ads :Z13NMO L • ,,,.,,M„.. ♦ E , CD ::. L L w LBJ 00 X 00 O— M O ler.. = N ■ • W Iz w,,,,,,,. U O V W Y• i 0 11.'" ZS' sigailM2111120312753110,3: , kY £ 1 v eratit7 la 4. � ... .................. v.....• ....a Lt woO•eoen•MMM 9090 (90Z) xj 00E9 4d 80696 VM'epee 44noS 'eAA 44L 669g 0 14 30 13 BOA aNVlinsNoo 3 £ w:1 mmmm m m m m ▪ m. 3 Ytix„xKKKxKk:tk..xx, , ,i...,..............,,,,..........., 4,„, .,,, Tp ,,,,,,,,,:r::::. �.. w,.,::..— .:..,....,... 4:- 4Rtp•. �:: m :.`' C,.^« , wawa ", m�„:Ftor c" 3313 IRI !R to 131 IRR llltltl t ItHIH 1i tIfl1 0 34 T, • ▪ •::In2.:. }:O ":r }:t } Y : 2 •C.:,•...: x: ..x : ::::::::..u,, v�,Y? :333 4 Yv tEY::`330 .::}a:: 33333,3;.•3$•333303..m.3.$3333:333.,3333,30...3.3•3:: • t •:.: ::...:.,,..,:....,. ,: .„. t . ,, .F•,•,g \`}'CT i i. '. iE ,,. 6 C Gt ,, ±low E`SlsaTk 1 }T It tttrnc 1 I 1 1 i �. 3 • 333 t f f h: vvxQ :• }:t 3.: 3. 3.:N:i 3. •.4 nvvvnv 3: 3 r �rNaxow,..r : „..:..,..:: 4tsvx •n Y' : {” K... M` R\^\, h: :.\, 1\\ 11:,`. 1 ` } }fi�'{ \ WOO'UOSIIIe3 MMM 9Z9p EZ9 90Z d 9119p EZ9 90Z £VEZ-60686 uoi 1 0111809 00pZ# emend 41/IA OM. NOSI V3 £ ko, �Ewro NOSI11Y3 • - 333:).343,3333:3333.3m•oro, 7333333.3.3333=e. u ,. t kx •kx "•'v ••x••Axv:;:r y:•vv.. Y .. .....n..h:`tik f } 3 xttxm,. w, vnukxsr: s:.: s.,... v:4,:krti(xnxawsT xcr:;anE rk:^s.x.H;a«&<eu..,,tatktix.. 1 C1 m m wmm ..: O. v��.! �: ttkr: AvN}: vtlr\ xKk:• rrrtk ` k::{{ {.:{imirnY { \i•:vU:ttkr4 r }rk.` }:A,ht�},.. w�:} hvvU4 'vUYUUU \ \:4H}hKtrM � w .w<w.,,. } i } �iYf.:.. W. GUYY' r. J.. JnU.y U. vxtt: tUx6YYk \:U'„tMrr: {{..x4,fttwWY.SkM � KN•UYYYYU'3,h+hvYY^ \NYUSU.U+ Y2 3} 3 a• ' 89196 VM `eI!M )Jn1 ®OB!d 1 .110Z1. 'S 99£E Sldilvo 1SV3 31V0H31NI UiAr/ 1JLdOS Zo - ZSaas U131N33 V1Y0 A�BYS . . ............ ............... ..� ... E 3 Y. a:,. YYaxa:. L, # 103rOad 3 bX E 4 f 3 3 { ,•t•.N:..,r:tte w O a_ O 1 O O V) O O O I- �— w C N- O O� U •> V) 4cexco.•auT'a U} r •:••:•,4•sre:au,,,..4n,YYYyrY;: E > : tttrt tt:•:.:, xs: to:..,x,uxx;w.,::�ra.tt.a4:,.,. d+t • rAto amee 0 LJ m .. ..tk:t z kr \.4.. , }..••Y' ti 4: E E3 } v:'1:: {K{{K{G{KKK,1 •^,... :.':...:..w ": .•.: -... :.::\ �i: tsiY > `:::•1'r , yp „ � , pp ,,.,, � , ; ,, r , ..,.. , ,.,.., , ,,.... ,.:.: •••••• s: D: tt.: ta+: ttti{;; a4x.: sr...:,.,, ..:.u..:.,wrt: ;kr.,,..,...,ttsY • i n........£M:S" \'r.":rk. .. . Y \`•.w w,,., Ki':: Cpll{,`: �ti ^".'^^"":"KKi:K:Si}:{:Y,,,,y:,: : a \.{,. r\.. til:::. tr} 1ti ,�::k_73:f.,,K{k }:::.:x: }x.:ti :,•.t:: w Q 0 0 w w w 0 w co W mww..tbk- #7 0) 0 0 SS 4 0 10 0 H /1 ;01j Z LLI 5 CI CC 8 d.1..1 0 cp Z vs co 11 M W J U (1) (±) z z vzoN O. W j Nirr Zo M ■ U. gm W W NOU) 0 cv ass CD OJ O ce ig (2) 6 "C, 3 #35OKCM, 2/0 GROUND 600A, 27KV 110KV BIL HVS -52A DIST. SWBD "HDP -52A" PNL 52A-L3 208/120 60A MCB PROV 5203 PNL M-52A 480 1800 MLO FUTURE 5203B 4000A BUS 480V- 30 -4W -65 KAIC PNL 52A-H1 480/277 100A MCB PNL 52A-L1 208/120 100A MCB PNL 52A -L2 208/120 100A MLO 1 #2/0 NEUTRAL XFR -52A -L 30KVA /480V TO ,208/120/ — 11 1 XFR -52A 3000 KVA AA 80'C 26A26A/15.3W-160/277V MBP -52- MNNT. BYPASS PANEL 1200A, 480V 30-3W SPACE FOR FUTURE BREAKER TO SYSTEM 6 52 -AC1 625KVA/ 5202 FUTURE 52018 KCDC 5201 STARUNE BUSWAY TO SITE POWER DISTRIBUTION T U PS -52 —A1 NC 1200AT 1200AT r, NOS 1 Bam FAC1 CA1 11D1 DAT 200AT _)1200AT_)1200AT 50/51N 600A, 27KV 11oKV BIL HVS -52B STARUNE BUSWAY XFR -52B 3000 KVA AA 80'C STS 52 -AB3 SFTLYR 5202 27KV SWITCHGEAR — MSG -2 27KV, 3PH, 4W, 1200A BUS 6 "C - 3 SINGLE CABLE #35OKCMIL, 35KV & 1# 2/0 GROUND, 1 #2/0 NEUTRAL MICROPROCESSOR BASED RELAY AND METERING– PNL 52 -AC2L1 208/120 1200AT_) 1200AT ) 1200AT 2500 KW 3125 KVA GENERATOR "GEN 52A" LJPS-52—A3 MBP -52 A3 MNNT BYPASS NC PANEL 480V 1200AT 1200AT 30-3W IRI NO STARUNE BUSWAY PE OF WORK 52 -AD3 27KV, 3PH, 4W, 1200A BUS TO COMMON LOAD PANEL 50/51N 600:5 MRCT () PNL PNL M-52B 528 -H1 480 480/277 1600 MLO 100A MCB 30-3W XFR- 52B-l3 ((c },r 15KVA T 208/ 1 208/120O V PNL 528-L3 208/120 60A MCB PNL 528 -L1 208/120 100A MCB PNL 528 -12 208/120 100A MLA LOADBANK SWBD LB-52B 3000A 480v 3P3W DIST. SWBD "HDP -52B" 4000A BUS 480V- 30 -4W -65 KAIC TO SITE POWER DISTRIBUTION T 1200A 52 -BA1 (2) 6 "C, 3 #350KCM, 1#2/0 GROUND II—III 1 #2/0 NEUTRAL 3 -LA 25003 UPS -52 -B1 562KW LOAD BANK LB-52 2000 KW STARUNE BUSWAY SPACE FOR FUTURE BREAKER TO SYSTEM 6 1200AT )1200AT)1200AT STS 52 -BC2 SFTLYR 5202 TO SYSTEM 5, SHEET NO. E5.5 (FUTURE) UPS -52 —B2 1200AT NO 1 MBP -52 B3 ANEL MMNT BYPASS NC 12DOA 480V 12ooaT 1E1 30 -3 W Egi 1200ATT 1200AT) PS -52 -83 2500 KW 3125 KVA GENERATOR "GEN -52B" PROV 5203 5202 _ __SUTURE 52018 KCDC 5201 FUTURE 52038 FUTURE 52018 KCDC 5201 STARUNE BUSWAY - SCOPE OF WORI INSTALL (3) MAIM BYPASS CABINETS TO BE FED TEMPORARILY FROM THREE EXISTING MBP'S PNL 52 -CB2L1 208/120 TO MBP -52 -A1 TEMP FEED TO MBP -52 -A3 TEMP FEED S15 52-CB1 SFTLYR 5202 5T5 52 -C83 SFILYR 5202 MBP -52 -C3 MAIM. BYPASS 4 NC PANEL 1200AT 1200AT 1200A 480V NO 30 -3W � 400 400 �F00 ! y ; £ 1.. ICA3 AC3 1083 803 CD3 003 STS 52 -CA3 KCDC 5201 SCOPE OF WORK STARUNE BUSWAY FEEDER SCHEDULE 3 —PHASE 4 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 504 1 "C - 4 #6 & 1 #1OG 604 1 1 /4 "C - 4 #4 & 1 #10G 704 1 1 /4 "C 4 #4 & 1 #8G 1004 1 1/2 "C 4 #1 & 1 #8G 1504 2 "C — 4 #1/O & 1 #6G 0 2 "C- 4 #4/O& 1 #4G 4004 3 -1/2 "C - 4 #500KCMIL & 1 #2G soo4 (2 SETS) 3 "C 3 #500KCMIL & 1 #1/0 NEUT. & 1 #1/0 GROUND 10004 (3 SETS) 3 - 1 /2 "C - 4 #400KCMIL & 1 #2/0 PER SET 30004 (8 SETS) 4 "C 4 #500KCMIL & 1 #400KCMIL G PER SET 40004 (10 SETS) 3.5 "C 3 -600, 1 -4 /ON, 1 -500G PER SET FLAG NOTES: o NOT USED STS TO HAVE (3) 225A OUTPUT BREAKERS — REMOVE EXISTING PM820 POWER METER & REPLACE WITH CM4000 FACTORY INSTALLED PM850 POWER METER FACTORY INSTAI I FD PM820 POWER METER © PROVIDE STATUS NOTIFICATION OF BREAKER POSmON VIA ACL MONITORING MONITOR AMPERAGE ONLY VIA ACL MONITORING ® STS TO HAVE (1) 400A OUTPUT BREAKER NOT USED 10 FOR FUTURE LOADS PROVIDE EATON XPERT 4000 POWER QUALITY METERS. FEEDER SCHEDULE 3 —PHASE 3 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE CONDUIT & WIRE SIZE + GROUND 203 1/2 "C - 3 #12& 1 #12G 303 3/4 "C — 3 #10 & 1 #1OG 403 3/4 "C - 3 #8 & 1 #1OG 503 3/4 "C — 3 #6 & 1 #10G 703 1 "C — 3 # & 1 #8G 1003 2 "C — 3 # 1 & 1 #8G 1503 2 "C — 3 #1/0 & 1 #6G 2003 2 "C - 3 #4/0 & 1 #6G 2503 2 - 1/2 "C — 3 #25OKCMIL & 1 #4G 4003 3 "C - 3 #500KCMIL & 1 #2G 5003 (2 SETS) 2 -1/2 "C — 3 #25OKCMIL & 1 #2G 8003 (2 SEES) 3 "C — 3 #500KCMIL & 1 #1/0 PER SET 12003 (3 SETS) 3 -1/2 "C - 3 #600KCMIL & 1 #3/O PER SET 16003 (4 SETS) 3 -1 /2 "C — 3 #600KCMIL & 1 #4 /OG PER SET 20003 (5 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #25OKCMIL PER SET 25003 (6 SETS) 3 - 1/2 "C 3 #600KCMIL & 1 #350 KCMIL G PER SET 30003 (8 SEES) 3 "C 3 #500KCMIL & 1 #400KCMIL G PER SET 40003 (10 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #500KCMIL G PER SET INSTALL (3) MAINT BYPASS CABINETS TO BE FED TEMPORARILY FROM THREE EXISiiNG MBP'S TO MBP -52 -B1 TEMP FEED TO MBP -52 -62 TE1,P FEED TO MBP -52 -83 TEMP FEED MDP -52 -D2 MNNT. BYPASS �, NC PANEL 1200AT 1200AT 1200A, 480r NO 30 -3W 400 £ , • • } • r , AD2 DB2 802 4102 CD2 1 # PROV 5203 M, FUTURE 52018 REVIEWED LIA E WITH CC NFPA70 -NEC Nov 05 2009 RECEIVED OCT 2 9 2009 PERMIT CENTER PERMIT SET IV L IJ a to J z 0 CO J J V O H wm z o Q) PERMIT SET REV. PHASE 1 E5.11 (0 C O 0 1 N LO M I d – O0 E - (0 ` OoLno _ ti O) I`) 0 3 OQ V . 0 N G) CO CO JD } E G; CNI CV c0 W '- 44. +. O(O v. 0 1 _ 4 - ' 0 0 N 0 0 N N N 00 •– L CJ) I- LL co O L() • O 0 O O • r ` F N O L 1 O 1 0 Q < . 4- N. (O W J 0 co CO > Z 0 Tr N N d O C.'tO U) Q L 0 O T1' 0 0 LL 0 N O co co _O 0) C CO LO N U) C6 d 0 Cr) Cr) N N NCOCO ,, CO CO +-'O0 N N (/) II- a) CO CO CI_ CO Q CV VJ Cr) Cr) ONE -LINE DIAGRAM 0 0 N CU 0 SSUED / REVISED DATE 10/12/09 10/15/09 itsj gi 400 (2) 6 "C, 3 #35OKCM, 2/0 GROUND 600A, 27KV 110KV BIL HVS -52A DIST. SWBD "HDP -52A" PNL 52A-L3 208/120 60A MCB PROV 5203 PNL M-52A 480 1800 MLO FUTURE 5203B 4000A BUS 480V- 30 -4W -65 KAIC PNL 52A-H1 480/277 100A MCB PNL 52A-L1 208/120 100A MCB PNL 52A -L2 208/120 100A MLO 1 #2/0 NEUTRAL XFR -52A -L 30KVA /480V TO ,208/120/ — 11 1 XFR -52A 3000 KVA AA 80'C 26A26A/15.3W-160/277V MBP -52- MNNT. BYPASS PANEL 1200A, 480V 30-3W SPACE FOR FUTURE BREAKER TO SYSTEM 6 52 -AC1 625KVA/ 5202 FUTURE 52018 KCDC 5201 STARUNE BUSWAY TO SITE POWER DISTRIBUTION T U PS -52 —A1 NC 1200AT 1200AT r, NOS 1 Bam FAC1 CA1 11D1 DAT 200AT _)1200AT_)1200AT 50/51N 600A, 27KV 11oKV BIL HVS -52B STARUNE BUSWAY XFR -52B 3000 KVA AA 80'C STS 52 -AB3 SFTLYR 5202 27KV SWITCHGEAR — MSG -2 27KV, 3PH, 4W, 1200A BUS 6 "C - 3 SINGLE CABLE #35OKCMIL, 35KV & 1# 2/0 GROUND, 1 #2/0 NEUTRAL MICROPROCESSOR BASED RELAY AND METERING– PNL 52 -AC2L1 208/120 1200AT_) 1200AT ) 1200AT 2500 KW 3125 KVA GENERATOR "GEN 52A" LJPS-52—A3 MBP -52 A3 MNNT BYPASS NC PANEL 480V 1200AT 1200AT 30-3W IRI NO STARUNE BUSWAY PE OF WORK 52 -AD3 27KV, 3PH, 4W, 1200A BUS TO COMMON LOAD PANEL 50/51N 600:5 MRCT () PNL PNL M-52B 528 -H1 480 480/277 1600 MLO 100A MCB 30-3W XFR- 52B-l3 ((c },r 15KVA T 208/ 1 208/120O V PNL 528-L3 208/120 60A MCB PNL 528 -L1 208/120 100A MCB PNL 528 -12 208/120 100A MLA LOADBANK SWBD LB-52B 3000A 480v 3P3W DIST. SWBD "HDP -52B" 4000A BUS 480V- 30 -4W -65 KAIC TO SITE POWER DISTRIBUTION T 1200A 52 -BA1 (2) 6 "C, 3 #350KCM, 1#2/0 GROUND II—III 1 #2/0 NEUTRAL 3 -LA 25003 UPS -52 -B1 562KW LOAD BANK LB-52 2000 KW STARUNE BUSWAY SPACE FOR FUTURE BREAKER TO SYSTEM 6 1200AT )1200AT)1200AT STS 52 -BC2 SFTLYR 5202 TO SYSTEM 5, SHEET NO. E5.5 (FUTURE) UPS -52 —B2 1200AT NO 1 MBP -52 B3 ANEL MMNT BYPASS NC 12DOA 480V 12ooaT 1E1 30 -3 W Egi 1200ATT 1200AT) PS -52 -83 2500 KW 3125 KVA GENERATOR "GEN -52B" PROV 5203 5202 _ __SUTURE 52018 KCDC 5201 FUTURE 52038 FUTURE 52018 KCDC 5201 STARUNE BUSWAY - SCOPE OF WORI INSTALL (3) MAIM BYPASS CABINETS TO BE FED TEMPORARILY FROM THREE EXISTING MBP'S PNL 52 -CB2L1 208/120 TO MBP -52 -A1 TEMP FEED TO MBP -52 -A3 TEMP FEED S15 52-CB1 SFTLYR 5202 5T5 52 -C83 SFILYR 5202 MBP -52 -C3 MAIM. BYPASS 4 NC PANEL 1200AT 1200AT 1200A 480V NO 30 -3W � 400 400 �F00 ! y ; £ 1.. ICA3 AC3 1083 803 CD3 003 STS 52 -CA3 KCDC 5201 SCOPE OF WORK STARUNE BUSWAY FEEDER SCHEDULE 3 —PHASE 4 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 504 1 "C - 4 #6 & 1 #1OG 604 1 1 /4 "C - 4 #4 & 1 #10G 704 1 1 /4 "C 4 #4 & 1 #8G 1004 1 1/2 "C 4 #1 & 1 #8G 1504 2 "C — 4 #1/O & 1 #6G 0 2 "C- 4 #4/O& 1 #4G 4004 3 -1/2 "C - 4 #500KCMIL & 1 #2G soo4 (2 SETS) 3 "C 3 #500KCMIL & 1 #1/0 NEUT. & 1 #1/0 GROUND 10004 (3 SETS) 3 - 1 /2 "C - 4 #400KCMIL & 1 #2/0 PER SET 30004 (8 SETS) 4 "C 4 #500KCMIL & 1 #400KCMIL G PER SET 40004 (10 SETS) 3.5 "C 3 -600, 1 -4 /ON, 1 -500G PER SET FLAG NOTES: o NOT USED STS TO HAVE (3) 225A OUTPUT BREAKERS — REMOVE EXISTING PM820 POWER METER & REPLACE WITH CM4000 FACTORY INSTALLED PM850 POWER METER FACTORY INSTAI I FD PM820 POWER METER © PROVIDE STATUS NOTIFICATION OF BREAKER POSmON VIA ACL MONITORING MONITOR AMPERAGE ONLY VIA ACL MONITORING ® STS TO HAVE (1) 400A OUTPUT BREAKER NOT USED 10 FOR FUTURE LOADS PROVIDE EATON XPERT 4000 POWER QUALITY METERS. FEEDER SCHEDULE 3 —PHASE 3 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE CONDUIT & WIRE SIZE + GROUND 203 1/2 "C - 3 #12& 1 #12G 303 3/4 "C — 3 #10 & 1 #1OG 403 3/4 "C - 3 #8 & 1 #1OG 503 3/4 "C — 3 #6 & 1 #10G 703 1 "C — 3 # & 1 #8G 1003 2 "C — 3 # 1 & 1 #8G 1503 2 "C — 3 #1/0 & 1 #6G 2003 2 "C - 3 #4/0 & 1 #6G 2503 2 - 1/2 "C — 3 #25OKCMIL & 1 #4G 4003 3 "C - 3 #500KCMIL & 1 #2G 5003 (2 SETS) 2 -1/2 "C — 3 #25OKCMIL & 1 #2G 8003 (2 SEES) 3 "C — 3 #500KCMIL & 1 #1/0 PER SET 12003 (3 SETS) 3 -1/2 "C - 3 #600KCMIL & 1 #3/O PER SET 16003 (4 SETS) 3 -1 /2 "C — 3 #600KCMIL & 1 #4 /OG PER SET 20003 (5 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #25OKCMIL PER SET 25003 (6 SETS) 3 - 1/2 "C 3 #600KCMIL & 1 #350 KCMIL G PER SET 30003 (8 SEES) 3 "C 3 #500KCMIL & 1 #400KCMIL G PER SET 40003 (10 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #500KCMIL G PER SET INSTALL (3) MAINT BYPASS CABINETS TO BE FED TEMPORARILY FROM THREE EXISiiNG MBP'S TO MBP -52 -B1 TEMP FEED TO MBP -52 -62 TE1,P FEED TO MBP -52 -83 TEMP FEED MDP -52 -D2 MNNT. BYPASS �, NC PANEL 1200AT 1200AT 1200A, 480r NO 30 -3W 400 £ , • • } • r , AD2 DB2 802 4102 CD2 1 # PROV 5203 M, FUTURE 52018 REVIEWED LIA E WITH CC NFPA70 -NEC Nov 05 2009 RECEIVED OCT 2 9 2009 PERMIT CENTER PERMIT SET IV L IJ a to J z 0 CO J J V O H wm z o Q) PERMIT SET REV. PHASE 1 E5.11 (0 C O 0 1 N LO M I d – O0 E - (0 ` OoLno _ ti O) I`) 0 3 OQ V . 0 N G) CO CO JD } E G; CNI CV c0 W '- 44. +. O(O v. 0 1 _ 4 - ' 0 0 N 0 0 N N N 00 •– L CJ) I- LL co O L() • O 0 O O • r ` F N O L 1 O 1 0 Q < . 4- N. (O W J 0 co CO > Z 0 Tr N N d O C.'tO U) Q L 0 O T1' 0 0 LL 0 N O co co _O 0) C CO LO N U) C6 d 0 Cr) Cr) N N NCOCO ,, CO CO +-'O0 N N (/) II- a) CO CO CI_ CO Q CV VJ Cr) Cr) ONE -LINE DIAGRAM 0 0 N CU 0 SSUED / REVISED DATE 10/12/09 10/15/09