Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL09-0727 - WESTFIELD SOUTHCENTER MALL - MOTHERHOOD MATERNITY
MOTHERHOOD MATERNITY 1057 SOUTHCENTER MALL ELO9-0727 Citylk Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://www.citulovila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 1057 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL09 -0727 Issue Date: 01/21/2010 Permit Expires On: 07/20/2010 Tenant: Name: MOTHERHOOD MATERNITY Address: 1057 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC BSIP Phone: Address: TOTAL 13 PARCEL NUMBERS , 2010 NEW PLAT MAJOR 920247 Contact Person: Name: LYN DAVIES Phone: 800- 285 -7866 X1 Address: 75 60TH ST SW , WYOMING MI Contractor: Name: CEDAR GROVE ELECTRIC INC Phone: 253 - 373 -0056 Address: 1819 CENTRAL AVE S SP 71 , KENT WA Contractor License No: CEDARGE955BC Expiration Date: 01/21/2011 DESCRIPTION OF WORK: ELECTRICAL PORTION OF TENANT IMPROVEMENT TO EXISTING MALL SPACE. NO CHANGE TO EXISTING METER, CONDUIT OR WIRE Value of Electrical: NRES: $9,500.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: 2008 $315.00 Date: 0—HO I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of thi rmit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t erformance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: Print Name: < � °� //ery:6,32n This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0727 Printed: 01 -21 -2010 Parcel No.: 6364200010 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: hitp : / /www.ci.tulnvila.wa.us PERMIT CONDITIONS 1057 SOUTHCENTER MALL TUKW MOTHERHOOD MATERNITY Permit Number: Status: Applied Date: Issue Date: EL09 -0727 ISSUED 11/18/2009 01/21/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building; such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: <177- Date :! 27.^ /o doc: Cond -Elec EL09 -0727 Printed: 01 -21 -2010 CITY OF TUKWILIP Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http. //www, ci: tukwila. wa. us Electrical Permit No. E 1_ q- 727 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: �-11i� Tenant Name: ./ t 7i eV / Vc/ 7(/W41 1 Property Owners Name: WQfr'�p/ Mailing Address: Mod/ I t/ ISLE vel King Co Assessor's Tax No.: ‘1, _36 y ZU_ - Suite Number: /505 Floor: New Tenant: xg. Yes ❑..No c State Je7oazV Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailing Address: 75 6D74-_ 41.4 vtrr_r City Fax Number: Day Telephone: E -Mail Address: 1 ui L17.- CC 15l oi... f1 e4/ . Cc' & Soo- z�S - 7g-6 ,,u I 4/951 e State Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): feuiadif a /a /on Pac. Ut eti.l TP•c . /Uo_ c o� '- V �P CIs A IM�T f/i LZ •e� Will service be altered? ❑ Yes No Type of Use: __ /ule -ree.w Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: Puget Sound Energy ❑ Seattle City Light H :\Applicatiom\Fomis- Applications On Line \1 - 2009 - Electrical Permit Application doc bh Adding more than 50 amps? ❑ Yes ❑ No ❑ Remodel AEC. Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $145.60 (including an attached garage) ❑ Garages, pools, spas and outbuildings $78 -00 ea ❑ Low voltage systems (alarm, furnace thermostat) $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78 -00 (no added/altered circuits) ❑ Service change with added/altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $57 -00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions - $10.00 ca PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: l / f 07 Print Name: Lyn / / A-t11 P Day Telephone: 800 a e5C7 7 6 (oh Mailing Address: .1/..2 .11' . Date Application Accepted: j `_. (j U wyomi �1 ygL� City State Zip Date Application Expires: � � ( 0 Staff Initials: H:Upplications \Forms- Applications On tie \1- 2009 - Electrical Permit Application.doc bb Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax; 206 -431 -3665 Web site: hup: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL09 -0727 Address: 1057 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 11/18/2009 Applicant: MOTHERHOOD MATERNITY Issue Date: Receipt No.: R10 -00085 Initials: User ID: Payee: WER 1655 Payment Amount: $252.00 Payment Date: 01/21/2010 10:57 AM Balance: $0.00 CEDAR GROVE ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Ctd VISA - Authorization No. 093503 ACCOUNT ITEM LIST: Description 252:03 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 252.00 Total: $252.00 PAYMENT RECEIVED doc: Receipt -06 Printed: 01 -21 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL09 -0727 Address: 1057 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/18/2009 Applicant: MOTHERHOOD MATERNITTY Issue Date: Receipt No.: R09 -01841 Initials: WER User ID: 1655 Payment Amount: $63.00 Payment Date: 11/18/2009 09:59 AM Balance: $252.00 Payee: PRECISION PERMIT SERVICE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6990 63.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 63.00 Total: $63.00 PYM E NT R cEivED doc: Receipt -06 Printed: 11 -18 -2009 INSPECTION RECORD 40,o72 Retain a copy with permit INSPE ION NO. PBRMIT NO. CITY OF TUKWILA BUILDING DIVISION f-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proj CO I 4'o P Type of Inspection: 21o0 Address: 1 /O57 tikR, Date Called: Special Instructions: Date Wanted: 21 11 a.m. Requester: Phone No: pproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 1:)/41, Inspector: Date: v I( / 0 II $60.00 REINSPECTION FEE REQ IRED. Prior to inspectioi, fee must be paid at 6300 Southcenter Blvd., S ite 100. Call to schedule reinspection. Receipt No.: Date: 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6t a721 P R- MIT NO. CITY OF TUKWILA BUILDING DIVISION W- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Proj �� `,��� l 'j'y[ !.`Nk Type of Inspection: �OV 9C Address: I Io57�,(- " t `� Date Called: -, Special Instructions: Date Wanted: % 4 �Jv/ r p.m. Requester: // Phone No: RAtirr- Doi - ;IN ElApproved per applicable codes. IDCorrections required prior to approval. COMMENTS: 9C °X- tanOVA kibtiAl■ °F Mt f IC )f L11.1 i4yiIJ(. RAtirr- Doi - ;IN I4 P. Cop( 0101, Inspector: Date: 02-76(1 /f0 ❑ $60.00 REIN ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit P`RMIT NO. CITY OF TUKWILA BUILDING DIVISION t- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proje Or 1 1 T pe of Inspection: 3 Address. 1o51 h ate Called: Special Instr cti ns: Date Wanted: w ' 3 °JIB a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: a� arwnfcl cc,Jc -ts � lo‘h,k1l Gere- Inspector: 2 iV D $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit MIT NO. (1 CITY OF TUKWILA BUILDING DIVISION IL' t` 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. P iltop tiorTtli4rt Proj ype of Inspection: 7000 ate Called: ,00 Add re3s • t 05 Special Instruc ions: Date Wanted: r 2 a.m • p.m. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. (1r— COMMENTS: Pot 0-1 IP 6K 5L4.3 cosiDvi. r)5 703 _ 04. (4m, ades Date: D to (lull l 0 17 $60.00 REIN PECTION FEE REQUIRED. Prior inspection, fe be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: CITY OF TUKWILA - BUILDING DIVISION 2006 Wasington State Nonresidential Energy Code Compliance Form Interior' Lighting Summary 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -110 ' Revised July 2007 Project Info O Project Address /old v �o� d Nt4f ern �'�� Date 1/_ t r- cy S , C.A. p ht.,' �/ For Building Department Use ._ nEyIE'A/ r. E ©� � COMPLIANCE WITH NFPA 70 - NEC l<wrt /%k IA/ .4 Applican e: ! / (k i9 e r„ CC " 5 i-A i kly G h ,n f <.i plicant Address: (3 S I/,/c s /-f it rf j�carXJ`K.� �l.4,7,,, ,.., t fiy Applicant Phone: s�/r 1/o -2$s$ 7(0,57 Project Description sf. dz Al" 11 Plans :d2 3 2009 g requirements. J • New Building • Addition I( Alteration to WSEC Section 1513 for controls and commissioni Compliance Option Q Prescriptive 0 Lighting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA 7-- •;1er _ • Sy .1 ' . • . ,+ ` nz l - c.i-a4 , ._ .ihicylla Alteration Exceptions (check appropriate box - sec. 1132.3) 72- •• •.—! • No changes are being made to the lighting 1 • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) ccupancy Description Allowed Watts per ft 2 ** Area in ft2 Allowed x Area 54tci /Saes - ■.: es DINIr161 1.50/ 1, S,; !31Y,J hau.0 fycir6 / /7Yd sf. dz Al" 5 i-,ck g oo,>> So SO..: 25- Tonle' 7-- •;1er _ -Xo 7o..4+ 72- ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 3 s Z 3 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed S4 /r, 2.)( Y rIa..ra,- -cSc,t% 13 I!`/ (6z Scle S TvrJ! He. J — 3 67 LSy6 5s%r.) Li'yL -r 2... 6o ILO h:./: V /11; I 1 Iu6,re scc.T 1 ,32 3 L tei' /el far L,\yLr 2. S'6 160 +e) / Cr L /..e0,' Nti.ti7f -t S�cn'T y 30 j Li? Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 3 v0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. RECEIVED NOV 18 2009 ELO9-, 07 27 ,'ERMIT CENTER CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -LPA Revised July 2007 Project Add Date ro�ec ress /1/61-64.4,,/,‘-6/e., Use this form if you are claiming any ceiling height adjustkients for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception ** Adjusted LPA Watts per ft2 ** From Table 15 -1 based on exceptions listed in footnotes • • PE T PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL09 -0727 DATE: 11 -18 -09 PROJECT NAME: MOTHERHOOD MATERNITY SITE ADDRESS: 1057 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division twi Public Works Fire Prevention n Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-19 -09 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire El Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: _ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions t Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 12 -17 -09 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip doc 2 -28 -02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by LEt1 to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company CEDAR GROVE ELECTRIC INC 2533730056 1819 CENTRAL AVE S SP 71 KENT WA 98032 KING Corporation UBI No. 602254353 Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 ACTIVE CEDARGE955BC ELECTRICAL CONTRACTOR 1/21/2005 1/21/2011 GENERAL UNUSED Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status CEDARGE995DW CEDAR GROVE ELECTRIC ELECTRICAL CONTRACTOR GENERAL UNUSED 3/16/2001 3/16/2005 OUT OF BUSINESS MASTER ELECTRICIAN INFORMATION License BATTEJT967C5 Name BATTERSON, J T Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date BATTERSON, J T AGENT 01/03/2005 BATTERSON, J T PRESIDENT 01/03/2005 https: // fortress .wa.gov /lni/bbip/Detail.aspx 01/21/2010 `1 I I • ADJACENT TENANT POWER PLAN SCALE 1/4" = 1' -0" B -6 MALL COMMON AREA POWER PLAN - CODED NOTES 1 RECEPTACLE MOUNTED ON CEILING FOR SHOW WNDOW AS REQUIRED BY N.E.C. #210 -62 O WATER HEATER (MOUNTED ABOVE CEILING). 1500 WATTS 0 ELECTRICAL POWER DISTRIBUTION LOCATION FOR STORE. SEE "PANEL SCHEDULE" AND "ELECTRICAL RISER DIAGRAM" ON SHEET E1.2 FOR FURTHER INFORMATION. FIELD VERIFY EXACT LOCATIONS AND REQUIREMENTS. 24" x 36" x 3/4" PLYWOOD TELEPHONE BACKER BOARD (AND QUADPLEX RECEPTACLE AT 48" A.F.F.) WITH 3/4" CONDUIT TO TELEPHONE SERVICE ENTRANCE (FlRE TREATED). WIRELESS SENSOR / ANNUNCIATOR SYSTEM BY "OPTEX, HRC -2 REMOTE RECEIVER (PLUG INTO RECEPTACLE) SUPPLIED BY DESTINATION MATERNITY, CORP. AND INSTALLED BY GENERAL CONTRACTOR. MOUNT RECEPTACLE AT 8"-0" A.F.F. 0 CONTRACTOR TO FURNISH AND INSTALL 3/4" CONDUIT AND CONDUCTORS TO TELEPHONE BACKER BOARD FOR CASHWRAP TELEPHONE, MODEM, AND FAX LINES. 0 DELIVERY BUZZER SYSTEM - EDWARDS #1786 -B PUSH- BUTTON, #590 SERIES TRANSFORMER AND #662 BUZZER MTH LOUVERED COVERPLATE AND TRANSFORMER MOUNTING PLATE SUPPLIED/ INSTALLED BY a C. 0 CONTRACTOR TO TRENCH SLAB AND INSTALL CONDUITS AS SHOWN. PATCH TRENCH TO MATCH EXISTING FINISH. 0 D.M.C. VENDOR TO FURNISH AND INSTALL WIRING FROM. THE TELEPHONE BOARD AND TWO SEPARATE RJ -11 JACKS (NOT JUST ONE JACK WITH A SPLITTER) FOR THE TELEPHONE AND DATA OUTLETS AT CASHWRAP (JACKS MUST BE LABELED WMMN A PERMANENT MARKER 141771 TELEPHONE NUMBERS). FIELD VERIFY EXACT LOCATIONS AND REQUIREMENTS. 10 DUPLEX RECEPTACLE (WITH ISOLATED GROUND) FOR CASH REGISTER. 11 12 DUPLEX RECEPTACLE ® 36" A.F.F. FOR MICROWAVE OVEN 13 DUPLEX RECEPTACLE FOR D.M.C. PROVIDED REFRIGERATOR. 16 QUADPLEX RECEPTACLE FOR CASHWRAP. MOUNT RECEPTACLE ON WALL, 6 FEET ABOVE FINISHED FLOOR FOR STEREO SYSTEM. EXTEND 1/2" CONDUIT AND AND (3) 22 GA. SPEAKER WIRE TO SPEAKER LOCATIONS SHOWN ON SHEET E1.1. CONTRACTOR TO FURNISH AND INSTALL RJ -11 JACK FOR THE TELEPHONE LINE DEDICATED TO FUTURE SECURITY SYSTEM. (CONTRACTOR PROVDE WRING FROM THE TELEPHONE BOARD TO RJ -11 JACK.) DEDICATED DUPLEX RECEPTACLE FOR FUTURE SECURITY SYSTEM. 17 WATERPROOF G.F.I. RECEPTACLE MOUNTED AT 42" A.F.F. 18 NEW OUTLET BY G.C. CONTRACTOR TO INSTALL ALL CONDUIT FOR TELCO EQUIPMENT D.M.C. COMMUNICATIONS VENDOR TO INSTALL FIXTURES. N 'mini" ' ,— \/ j I \/ `d r 1 . 11!L =--9ii 1.,__,=,. 0 hi..,IL m il __ ill I I I . II, B-40 r� *6.._meow B -32 B -18 B -28 POWER GENERAL NOTES 1. CONTRACTOR IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW THE DRAWINGS OF ALL DIVISIONS OF WORK CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK IT IS THIS CONTRACTOR'S RESPON- SIBILITY TO PROVIDE ALL THE SUBCONTRACTORS WTN A COMPLETE SET OF BID DOCUMENTS 2. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMA 7/C FOR CLARITY CIRCUITING SHALL BE "THRU- WIRING" WHERE AND WHENEVER POSSIBLE. 3. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT 4. ALL RECEPTACLE CIRCUITS UP TO 100' -0" SHALL UTILIZE #12 CONDUCTORS MINIMUM; 101' -0" TO 150' - #10, 151' -0" TO 250' -0" - #8 ; 251' -0" AND ABOVE - /6. 5. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS). IF RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCA7 /ON, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANT'S CONSTRUC77ON MANAGER PRIOR TO ROUGH -IN. MOUNT AT 15" A.F.F. UNLESS NOTED OTHERWISE. 6. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. SEE SHEET E1.2 FOR DETAILS, SCHEDULES, AND SPECIFICATIONS z IN STORES THAT CALL OUT FOR THE INSTALLATION OF WALL SYSTEM, ALL RECEPTACLES ARE TO BE INSTALLED SO THAT THEY ARE FLUSH TO THE FACE OF THE WALL SYSTEM. CONDUITS AT CASHWRAP TO BE SUBBED UP 1': RUN FLEX CONDUIT TO RECEPTACL S MOUNTED AT BACK OF CASHWRAP. CONDUIT FOR PHONE AND DATA RECEPTACLES IS NOT REQUIRED. (FIXTURES TO BE INSTALLED AS S IN CASHWRAP PLAN DETAIL.) ADJACENT TEN B -4 ELECTRICAL LEGEND 4 DUPLEX RECEPTACLE QUADPLEX RECEPTACLE CEILING MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED QUADPLEX RECEPTACLE TELCO EQUIPMENT LEI DISCONNECT SWITCH 0 JUNCTION BOX WALL SWITCH *** NEW FIXTURES ARE BOLD * ** ISOLATED GROUND DUPLEX RECEPTACLE Dl 1000 WATT SLIDE TO OFF DIMMER $ D2 1500 WATT SLIDE TO OFF DIMMER 5i WIRELESS SENSOR / ANNUNCIATOR By Date: / City Of 1Ukwiia BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: Me'chanice! ❑ Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 2 3 2009 City of kwila BUILDING ' IVISION FILE CO !''`Y Permit No. 11N ° 2� Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved F Copy and conditions is acknowledged: QUADPLEX RECEPTACLE 2 INPUT COMMUNICATION OUTLET LANDLORD NOTES LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE. TRAY ANY OTHER WALL PENETRATIONS WLL NEED TO BE FIRE CAULKED AS REQUIRED. LANDLORD NOTES 1. LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVE JURISDICTION. TENANT SHALL CONTRACT LANDLORD'S DESIGNED FlRE ALARM CONTRACTOR FOR DESIGN, PROGRAMMING AND FINAL CONNECTIONS TO LANDLORD'S SYSTEM AT TENANT'S EXPENSE. TENANT SHALL USE ONLY LANDLORD DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. A COPY OF FIRE ALARM DRAWINGS SHALL BE ISSUED TO LOCAL FIRE MARSHALL'S OFFICE. 2 TENANT SHALL FURNISH AND INSTALL DUCT DETECTORS WITH REMOTE TEST SWITCH AND LED INDICATOR LIGHTS IN SUPPLY AND RETURN MAINS FOR EACH TENANT VAV UNIT AS REQUIRED BY CODE AND LOCAL AUTHORITY HAI4NG JURISDIC770N. GENERAL LANDLORD NOTES EFFECTIVE JULY 1, 2007 THE CITY OF TUKWILA WILL BE UNDER THE 2006 INTERNATIONAL CODES AND ALL PERMIT SUBMITTALS NEED TO BE IN CONFORMANCE IRTH THIS EDI TTON. 2. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS 3. TENANT SHALL PROPERLY SEAL ALL PENETRATIONS TO COMPLY WITH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY SHALL BE MAINTAINED. ALL PLUMBING, MECHANICAL AND ELECTRICAL DEICES PENETRATING FLOOR SHALL BE FIRE RATED. 4. TENANT ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION TO PREVENT DISTURBANCE OF LANDLORD'S BELOW GRADE UTILITIES ON COMPLETION OF BELOW GRADE WORK, TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB ON GRADE INCLUDING GRAVEL LAYERS, VAPOR BARRIER AND CONCRETE 5. TENANTS CONTRACTOR IS TO VERIFY LOCATION; GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH WESTFIELD'S ON -SITE TENANT COORDINATORS BEFORE PRECEDING WORK TENANTS CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE EVERY WELDING IS, DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL, REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF IUKWILA. CA T5 INTERNET CABLE DUPLEX RECEPTACLE INDICATES ACCESS PANEL IN BOTTOM OF CASHWRAP (TYP OF 2) SLAB). SEE PLAN FOR TRENCHING INFO. CASHWRAP ELEVATION (EMPLOYEE SIDE) SCALE NTS O FLEX CONDUIT FLOOR MOUNTED JUNCTION BOX RIG CONDU (IN CONCRETE u�4 GROMMET IN COUNTERTOP 2 INPUT COMMUNICATIONS OUTLET ISOLATED GROUND DUPLEX CA T5 INTERNET CABLE FLEX CONDUIT FLOOR MOUNTED JUNCTION BOX CASHWRAP PLAN SCALE. NTS F CASHWRAP QUADPLEX RECEPTACLE CASHWRAP CUSTOMER INDICATES "CHASE" IN CABINET BIM./ DECK ONLY. RIGID CONDUIT (IN CONCRETE II SLAB). SEE PLAN FOR I I I TRENCHING INFO. I EMPLOYEE SIDE , 1" G.C. TO FIELD CUT ACCESS PANEL (AS REQUIRED FOR CONDUIT) INDICATES ACCESS PANEL IN BOTTOM OF CASWRAP. (TYP OF 2) *ALL ELECTRICAL FIXTURES ARE TO BE SUPPLIED AND INSTALLED BY G.C. ELO9 0727 RECEIVED NOV 18 2009 'ERMIT CENTFr DMC STORE # 4083 RELOCATION ARCHITECT OF RECORD: C O R T L A N D CWIA M 0 R G A N A R C H I T E C T 711 NORTH FIELDER ROAD ARLINGTON, TEXAS 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 CL I- 0 C5 U ET; rg z to Q �Lo¢ z = ¢0 cn co C3 d am - a e .... mon JO :::1::: Z oo : � o W a� � �C 4'th'I �z� z = U W u O Filas4 1°' co I-- L 0 0 44 ,- 2 0 w OD 0 0 r N �... p N I o Lo N 0 = w Z CD N W 0 DRAWN BY: C.M. ELECTRICAL PLAN E1.0 1_111 flaw/ II Iirr 0 111 Aili I -I 4 1 `1 I I • ADJACENT TENANT POWER PLAN SCALE 1/4" = 1' -0" B -6 MALL COMMON AREA POWER PLAN - CODED NOTES 1 RECEPTACLE MOUNTED ON CEILING FOR SHOW WNDOW AS REQUIRED BY N.E.C. #210 -62 O WATER HEATER (MOUNTED ABOVE CEILING). 1500 WATTS 0 ELECTRICAL POWER DISTRIBUTION LOCATION FOR STORE. SEE "PANEL SCHEDULE" AND "ELECTRICAL RISER DIAGRAM" ON SHEET E1.2 FOR FURTHER INFORMATION. FIELD VERIFY EXACT LOCATIONS AND REQUIREMENTS. 24" x 36" x 3/4" PLYWOOD TELEPHONE BACKER BOARD (AND QUADPLEX RECEPTACLE AT 48" A.F.F.) WITH 3/4" CONDUIT TO TELEPHONE SERVICE ENTRANCE (FlRE TREATED). WIRELESS SENSOR / ANNUNCIATOR SYSTEM BY "OPTEX, HRC -2 REMOTE RECEIVER (PLUG INTO RECEPTACLE) SUPPLIED BY DESTINATION MATERNITY, CORP. AND INSTALLED BY GENERAL CONTRACTOR. MOUNT RECEPTACLE AT 8"-0" A.F.F. 0 CONTRACTOR TO FURNISH AND INSTALL 3/4" CONDUIT AND CONDUCTORS TO TELEPHONE BACKER BOARD FOR CASHWRAP TELEPHONE, MODEM, AND FAX LINES. 0 DELIVERY BUZZER SYSTEM - EDWARDS #1786 -B PUSH- BUTTON, #590 SERIES TRANSFORMER AND #662 BUZZER MTH LOUVERED COVERPLATE AND TRANSFORMER MOUNTING PLATE SUPPLIED/ INSTALLED BY a C. 0 CONTRACTOR TO TRENCH SLAB AND INSTALL CONDUITS AS SHOWN. PATCH TRENCH TO MATCH EXISTING FINISH. 0 D.M.C. VENDOR TO FURNISH AND INSTALL WIRING FROM. THE TELEPHONE BOARD AND TWO SEPARATE RJ -11 JACKS (NOT JUST ONE JACK WITH A SPLITTER) FOR THE TELEPHONE AND DATA OUTLETS AT CASHWRAP (JACKS MUST BE LABELED WMMN A PERMANENT MARKER 141771 TELEPHONE NUMBERS). FIELD VERIFY EXACT LOCATIONS AND REQUIREMENTS. 10 DUPLEX RECEPTACLE (WITH ISOLATED GROUND) FOR CASH REGISTER. 11 12 DUPLEX RECEPTACLE ® 36" A.F.F. FOR MICROWAVE OVEN 13 DUPLEX RECEPTACLE FOR D.M.C. PROVIDED REFRIGERATOR. 16 QUADPLEX RECEPTACLE FOR CASHWRAP. MOUNT RECEPTACLE ON WALL, 6 FEET ABOVE FINISHED FLOOR FOR STEREO SYSTEM. EXTEND 1/2" CONDUIT AND AND (3) 22 GA. SPEAKER WIRE TO SPEAKER LOCATIONS SHOWN ON SHEET E1.1. CONTRACTOR TO FURNISH AND INSTALL RJ -11 JACK FOR THE TELEPHONE LINE DEDICATED TO FUTURE SECURITY SYSTEM. (CONTRACTOR PROVDE WRING FROM THE TELEPHONE BOARD TO RJ -11 JACK.) DEDICATED DUPLEX RECEPTACLE FOR FUTURE SECURITY SYSTEM. 17 WATERPROOF G.F.I. RECEPTACLE MOUNTED AT 42" A.F.F. 18 NEW OUTLET BY G.C. CONTRACTOR TO INSTALL ALL CONDUIT FOR TELCO EQUIPMENT D.M.C. COMMUNICATIONS VENDOR TO INSTALL FIXTURES. N 'mini" ' ,— \/ j I \/ `d r 1 . 11!L =--9ii 1.,__,=,. 0 hi..,IL m il __ ill I I I . II, B-40 r� *6.._meow B -32 B -18 B -28 POWER GENERAL NOTES 1. CONTRACTOR IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW THE DRAWINGS OF ALL DIVISIONS OF WORK CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK IT IS THIS CONTRACTOR'S RESPON- SIBILITY TO PROVIDE ALL THE SUBCONTRACTORS WTN A COMPLETE SET OF BID DOCUMENTS 2. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMA 7/C FOR CLARITY CIRCUITING SHALL BE "THRU- WIRING" WHERE AND WHENEVER POSSIBLE. 3. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT 4. ALL RECEPTACLE CIRCUITS UP TO 100' -0" SHALL UTILIZE #12 CONDUCTORS MINIMUM; 101' -0" TO 150' - #10, 151' -0" TO 250' -0" - #8 ; 251' -0" AND ABOVE - /6. 5. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS). IF RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCA7 /ON, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANT'S CONSTRUC77ON MANAGER PRIOR TO ROUGH -IN. MOUNT AT 15" A.F.F. UNLESS NOTED OTHERWISE. 6. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. SEE SHEET E1.2 FOR DETAILS, SCHEDULES, AND SPECIFICATIONS z IN STORES THAT CALL OUT FOR THE INSTALLATION OF WALL SYSTEM, ALL RECEPTACLES ARE TO BE INSTALLED SO THAT THEY ARE FLUSH TO THE FACE OF THE WALL SYSTEM. CONDUITS AT CASHWRAP TO BE SUBBED UP 1': RUN FLEX CONDUIT TO RECEPTACL S MOUNTED AT BACK OF CASHWRAP. CONDUIT FOR PHONE AND DATA RECEPTACLES IS NOT REQUIRED. (FIXTURES TO BE INSTALLED AS S IN CASHWRAP PLAN DETAIL.) ADJACENT TEN B -4 ELECTRICAL LEGEND 4 DUPLEX RECEPTACLE QUADPLEX RECEPTACLE CEILING MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED QUADPLEX RECEPTACLE TELCO EQUIPMENT LEI DISCONNECT SWITCH 0 JUNCTION BOX WALL SWITCH *** NEW FIXTURES ARE BOLD * ** ISOLATED GROUND DUPLEX RECEPTACLE Dl 1000 WATT SLIDE TO OFF DIMMER $ D2 1500 WATT SLIDE TO OFF DIMMER 5i WIRELESS SENSOR / ANNUNCIATOR By Date: / City Of 1Ukwiia BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: Me'chanice! ❑ Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 2 3 2009 City of kwila BUILDING ' IVISION FILE CO !''`Y Permit No. 11N ° 2� Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved F Copy and conditions is acknowledged: QUADPLEX RECEPTACLE 2 INPUT COMMUNICATION OUTLET LANDLORD NOTES LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE. TRAY ANY OTHER WALL PENETRATIONS WLL NEED TO BE FIRE CAULKED AS REQUIRED. LANDLORD NOTES 1. LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVE JURISDICTION. TENANT SHALL CONTRACT LANDLORD'S DESIGNED FlRE ALARM CONTRACTOR FOR DESIGN, PROGRAMMING AND FINAL CONNECTIONS TO LANDLORD'S SYSTEM AT TENANT'S EXPENSE. TENANT SHALL USE ONLY LANDLORD DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. A COPY OF FIRE ALARM DRAWINGS SHALL BE ISSUED TO LOCAL FIRE MARSHALL'S OFFICE. 2 TENANT SHALL FURNISH AND INSTALL DUCT DETECTORS WITH REMOTE TEST SWITCH AND LED INDICATOR LIGHTS IN SUPPLY AND RETURN MAINS FOR EACH TENANT VAV UNIT AS REQUIRED BY CODE AND LOCAL AUTHORITY HAI4NG JURISDIC770N. GENERAL LANDLORD NOTES EFFECTIVE JULY 1, 2007 THE CITY OF TUKWILA WILL BE UNDER THE 2006 INTERNATIONAL CODES AND ALL PERMIT SUBMITTALS NEED TO BE IN CONFORMANCE IRTH THIS EDI TTON. 2. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS 3. TENANT SHALL PROPERLY SEAL ALL PENETRATIONS TO COMPLY WITH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY SHALL BE MAINTAINED. ALL PLUMBING, MECHANICAL AND ELECTRICAL DEICES PENETRATING FLOOR SHALL BE FIRE RATED. 4. TENANT ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION TO PREVENT DISTURBANCE OF LANDLORD'S BELOW GRADE UTILITIES ON COMPLETION OF BELOW GRADE WORK, TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB ON GRADE INCLUDING GRAVEL LAYERS, VAPOR BARRIER AND CONCRETE 5. TENANTS CONTRACTOR IS TO VERIFY LOCATION; GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH WESTFIELD'S ON -SITE TENANT COORDINATORS BEFORE PRECEDING WORK TENANTS CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE EVERY WELDING IS, DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL, REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF IUKWILA. CA T5 INTERNET CABLE DUPLEX RECEPTACLE INDICATES ACCESS PANEL IN BOTTOM OF CASHWRAP (TYP OF 2) SLAB). SEE PLAN FOR TRENCHING INFO. CASHWRAP ELEVATION (EMPLOYEE SIDE) SCALE NTS O FLEX CONDUIT FLOOR MOUNTED JUNCTION BOX RIG CONDU (IN CONCRETE u�4 GROMMET IN COUNTERTOP 2 INPUT COMMUNICATIONS OUTLET ISOLATED GROUND DUPLEX CA T5 INTERNET CABLE FLEX CONDUIT FLOOR MOUNTED JUNCTION BOX CASHWRAP PLAN SCALE. NTS F CASHWRAP QUADPLEX RECEPTACLE CASHWRAP CUSTOMER INDICATES "CHASE" IN CABINET BIM./ DECK ONLY. RIGID CONDUIT (IN CONCRETE II SLAB). SEE PLAN FOR I I I TRENCHING INFO. I EMPLOYEE SIDE , 1" G.C. TO FIELD CUT ACCESS PANEL (AS REQUIRED FOR CONDUIT) INDICATES ACCESS PANEL IN BOTTOM OF CASWRAP. (TYP OF 2) *ALL ELECTRICAL FIXTURES ARE TO BE SUPPLIED AND INSTALLED BY G.C. ELO9 0727 RECEIVED NOV 18 2009 'ERMIT CENTFr DMC STORE # 4083 RELOCATION ARCHITECT OF RECORD: C O R T L A N D CWIA M 0 R G A N A R C H I T E C T 711 NORTH FIELDER ROAD ARLINGTON, TEXAS 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 CL I- 0 C5 U ET; rg z to Q �Lo¢ z = ¢0 cn co C3 d am - a e .... mon JO :::1::: Z oo : � o W a� � �C 4'th'I �z� z = U W u O Filas4 1°' co I-- L 0 0 44 ,- 2 0 w OD 0 0 r N �... p N I o Lo N 0 = w Z CD N W 0 DRAWN BY: C.M. ELECTRICAL PLAN E1.0 " MOTHERHOOD" LIGHTING FIXTURE SCHEDULE NOTE FIXTURE TO BE FURNISHED BY D.M.C. UNLESS NOTED OTHERWISE. SYMBOL DESCRIP770N MANUFACTURER / PART NO. LAMP / VOLTS WATTS REMARKS 0 RECESSED INCANDESCENT DOWN LIGHT - STOREFRONT LIGHTING CONTECH IRL38/3801 WHT 80PAR38/HIRFL, 120V 80 G.C. TO CLEAN AND REFURBISH TO LIKE NEW CONDITION POWER TRACK (LENGTH AS NOTED) CONTECH TRACK (WHITE) 2, 4, 6, & 8 FT POWER TRACK LENGTHS 120V - - TRACK TO BE MOUNTED TO THE LAY IN CEILING GRID. G C TO CLEAN AND REFURBISH TO LIKE NEW CONDITTON ) ( V 67 W PAR 38 TRACK HEAD SIDE CENTER FOCAL LIGHT CONTECH CTL838/2P GIMBAL RING RXTURE (WHITE) 67PAR/HIR+/FL25 120V 67 RECESSED 2 x 4 FLUORESCENT LIGHT - EXIST'G LIGHT LOCA770N DASHED LIGHT INDICATES ORIGINAL PLACEMENT FOR LIGHT FIXTURE. 4' (1) LAMP FLUORESCENT STRIP CRESCENT j4 C132 BALLAST ELECTRONIC B (1) F032/B35 120V 32 SURFACE MOUNTED ON CEILING. LINEAR FLUORESCENT U77LITY WALL LUMINAIRES NEW ENGLAND ACB215WRSW 15W-T12 120V 30 MOUNTED IN CLOSET ABOVE DOORS I H EXIT LIGHT CRESCENT iSCF1328 INCLUDED 120/277 12 RED LETTERS ON WHITE BACKGROUND W/ BATTERY PACK FOR 90 MINUTE EMERGENCY DUTY SEE PLAN FOR LOCA710N(S). c■Pr ,......, 1)=1 EMERGENCY LIGHT CRESCENT ICPELW2E INCLUDED 120/277 - - BACK MOUNTED DOUBLE HEADED EMERGENCY LIGHT WITH BATTERY PACK 0 SPEAKER "A TLAS SOUND" STRATEGY SERIES II. #FAP62T40-5041 - - 6" COAXIAL SPEAKER PURCHASED BY CONTRACTOR THRU "An.As SOUND" (800) 876-3333 EXISTING LIGHTING FIXTURE SCHEDULE (BY LANDLORD) SYMBOL DESCRIP770N REMARKS RECESSED 2 x 4 FLUORESCENT LIGHT - GENERAL LIGH77NG G.C. TO CLEAN AND REFURBISH TO LIKE NEW CONDITION EX. RECESSED 2 x 4 FLUORESCENT LIGHT - EMERGENCY LIGHTING G.C. TO CLEAN AND REFURBISH TO LIKE NEW CONDITION r r-- 4' 7<--- (NL) RECESSED 2 x 4 FLUORESCENT LIGHT - RELOCATED LIGHT G C TO CLEAN AND REFURBISH TO LIKE NEW CONDITTON R r — — — - 1 L EXJ RECESSED 2 x 4 FLUORESCENT LIGHT - EXIST'G LIGHT LOCA770N DASHED LIGHT INDICATES ORIGINAL PLACEMENT FOR LIGHT FIXTURE. @ RECESSED INCANDESCENT LIGHT - GENERAL LIGHTTNG G.C. TO CLEAN AND REFURBISH TO LIKE NEW CONDMON LIGHTING PLAN SCALE 1/4" = NOTE REPLACE ANY/ALL BURNED OUT LAMP. FIELD VERIFY EXISTING LAMP TYPE, THERE SHOULD BE NO MIXING OF COOL AND WARMLAMPS. REPLACE WITH COOL LAMPS AS/IF REQUIRED. NOTE. G.C. TO VERIFY IN FIELD THAT ALL EXISTING 2x4 LIGHTING ARE 277V ADJACENT TENANT LANDLORD NOTES 1. TENANT'S LIGHTING AND LIGHTING CONTROLS SYSTEM SHALL COMPLY PM THE WASHINGTON STATE NON RESIDENTTAL ENERGY CODE. 2. STORE FRONT SIGNAGE AND LIGHTTNG TIME CLOCKS SHALL BE SET TO MALL'S OPERATING HOURS. GENERAL LANDLORD NOTES 1. EFFECTIVE JULY 1, 2007 THE CITY OF TUKOILA MU BE UNDER THE 2006 INTERNATIONAL CODES AND ALL PERMIT SUBMITTALS NEED TO BE IN CONFORMANCE WITH THIS ED1770N. 2 TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE IVTH ALL INTHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS 3. TENANT SHALL PROPERLY SEAL ALL PENETRA77ONS TO COMPLY HUH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY SHALL BE MAINTAINED. ALL PLUMBING, MECHANICAL AND ELECTRICAL DEWCES PENETRATING FLOOR SHALL BE FIRE RATED. 4. TENANT ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE HITH LANDLORD PRIOR TO ANY SLAB DEMOLITTON TO PREVENT DISTURBANCE OF LANDLORD'S BELOW GRADE UTTLITTES. ON COMPLETTON OF BELOW GRADE WORK, TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB ON GRADE INCLUDING GRAVEL LAYERS, VAPOR BARRIER AND CONCRETE. 5. TENANTS CONTRACTOR IS TO VERIFY LOCA770N; GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING NTH WESTFIELD'S ON-SITE TENANT COORDINATORS BEFORE PRECEDING WORK. 6. TENANTS CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE EVERY WELDING IS DONE PlITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETTON OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA. LIGHTING GENERAL NOTES 1. CONTRACTOR IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW THE DRAWINGS OF ALL DMSIONS OF WORK CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS HUH ALL DMSIONS OF WORK IT IS THIS CONTRACTOR'S RESPON- SIBILITY TO PROWDE ALL THE SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS 2. CIRCUITTNG INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY CIRCUITING SHALL BE "THRU-WRING" WHERE AND WHENEVER POSSIBLE. 3. ALL RECEPTACLE CIRCUITS UP TO 100'-0" SHALL UTTLIZE #12 CONDUCTORS MINIMUM; 101'-0" TO 150' - #10, 151'-0" TO 250'-0" - #8 , 251'-0" AND ABOVE - #6. 4. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. SEE SHEET E1.2 FOR DETAILS, SCHEDULES, AND SPECIFICATIONS REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 23 2009 City of Tukwila BUILDING DIVISION EL09 07 RECEIVED NOV 1 8 2009 PERMIT CENTER POWER LIGHTING PLAN - CODED NOTES TENANT FURNISHED 'OPTEX' IVRELESS MOTION SENSOR (BRACKET AND INSTALLATION BY CONTRACTOR). MOUNT NEAR THE STOREFRONT OPENING. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. O CEILING MOUNTED TOILET EXHAUST FAN BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO HIRE THRU LIGHT SNITCH. LOCATION OF LIGHT SWITCHES FOR 'SALE' AREA LIGHT RXTURES, ONE PER CIRCUIT GANG NO MORE THAN (4) TOGETHER (STACK AS REQUIRED). FIELD VERIFY EXACT LOCATION AND REQUIREMENTS, STOREFRONT FIXTURES AND STAGGERED SIGN FIXTURES ARE NOT INCLUDED. O 120V., 10, 20 AMP CIRCUIT FOR STOREFRONT SIGN. FURNISH WITH DISCONNECT MEANS PER N.E.C. FIELD VERIFY EXACT LOCATTON AND REQUIREMENTS. 0 EXTEND 1/2" CONDUIT FROM SPEAKER BACK TO STEREO SYSTEM. SPEAKERS SHOWN FOR INTENT FINAL PLACEMENT AND QUANTITY DETERMINED BY MUSIC VENDOR. O PROPOSED LOCATION OF STEREO EQUIPMENT DMC STORE # 4083 RELOCATION ARCHITECT OF RECORD: CIA CORTLAND MORGAN ARCHITECT 711 NORTH FIELDER ROAD ARLINGTON, TEXAS 76012 PH: (817) 635-5696 FAX: (817) 635-5699 C/) oo s c\1 (no- NI LC) CY) w Z CL Ct w 11 1 2 . LLI z 0 111 = 0 I I 6 —= C/)0 Cl) LC) CD N" I - 4 Co Co Co N. 0 W 8 Lk n m 04 co i a rn CD r. 00 (-N M 1 ° M v DRAWN BY: C.M. LIGHTING PLAN El EX. PANEL B Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 225 Amp M.L.O. 14972 NEMA 1 RFM CKT DFSCRIPTION WATTS WIRE RKR A B C BKR WIRE DFSCRIPTION WATTS CKT RFM 8.0 1 SPARE 1500 10 1/20 X 1.25 x LARGEST CAMP 1 X REMAINDER 1/20 12 SHOW WIN. RECEPT. 1500 2 TC 3 STRFRNT TRACK 600 12 1/20 X AMPS AT 120/208V = / 360 = AMPS AMPS AT 277/480V = 21600 / 831 = 25.9 AMPS 1/20 ' 12 SHOW WIN. RECEPT. 1500 4 5040 6 5 SPARE 7 2x4 SALES LTS 1/20 12 X 1/20 12 SALES RECEPT. 1080 6 8 7 SPARE 9 2x4 SALES LTS 1/20 X 1/20 1/20 X SPARE 12 8 534 10 9 SPARE 11 STOREFRONT LTS 1/20 X 1/20 1120 12 GFI RECEPT. 180 10 b 11 TRACK LIGHTING 1200 12 1/20 X 1/20 SPARE 12 b 13 TRACK LIGHTING 1200 12 1/20 X 1/20 1/20 X SPARE 14 b 15 TRACK LIGHTING 900 12 1/20 X 1/20 1/20 12 TELCO 360 16 LD TC 17 STOREFRONT SIGN 1200 12 1/20 X 1/20 12 CASH REG. 180 18 IG 20 19 NEW WTR HTR 1500 12 1/20 X 1/20 1/20 X SPARE 20 22 21 CLOSET /RR LTS 402 12 1/20 X 1/20 1/20 12 SENSOR 180 22 LD 24 23 SPARE 25 SPARE 1/20 X 1/20 SPARE 24 26 25 SPARE 27 SPARE 1/20 X 1/20 1/20 X SPARE 26 28 27 SPARE 29 SPARE 1/20 X 1/20 1/20 12 CASH DESK REC, 360 28 IG 30 29 SPARE 1/20 X 1/20 12 SECURITY 180 30 I r) 31 SPARE 1/20 X 1/20 12 REFRIGERATOR 750 32 33 SPARE 1/20 X 1/20 SPARE 34 35 SPARE 1/20 X 1/20 12 MICROWAVE 1200 36 37 SPARE 1/20 X 1/20 SPARE 38 39 SPARE 1/20 X 1/20 12 SOUND SYSTEM 500 40 41 SPARE 1/20 X 1/20 SPARE 42 TOTAL LOAD PHASE 'A' 4950 REMARKS TOTAL LOAD PHASE 'B' 4982 (TC) TIME CLOCK CONTROLLED TOTAL LOAD PHASE 'C' 5040 (-) VIA CONTACTOR ( a or b ) (LD) LOCK -ON DEVICE TOTAL LOAD ALL PHASES 14972 WATTS (IG) ISOLATED GROUND 41.59 AMPS (HR) HACR RATED CB (SD) SWITCHING DUTY CB EX. PANEL H Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 225 Amp Main Circuit Breaker 125 Amp Total Watts: 21594 NEMA 1 RFM CKT DFSCRIPTION WATTS WIRE RKR A B C BKR WIRE DESCRIPTION WATTS CKT REM 8.0 1 EX. VAV 1500 10 3/30 X 1.25 x LARGEST CAMP 1 X REMAINDER 3 /10C 1 EX. 75 KVA XFMR 4950 2 HR 3 1500 TOTAL X 4982 4 AMPS AT 120/208V = / 360 = AMPS AMPS AT 277/480V = 21600 / 831 = 25.9 AMPS 5 1500 5040 6 a 7 2x4 SALES LTS 768 12 1/20 X 1/20 SPARE 8 a 9 2x4 SALES LTS Mn 12 1/20 X 1/20 12 NL /EMER/EXIT LTS 534 10 LD TC 11 STOREFRONT LTS 180 12 1/20 X 1/20 SPARE 12 13 SPARE 1/20 X 1/20 SPARE 14 15 SPARE 1/20 X 1/20 SPARE 16 17 SPARE 1/20 X 1/20 SPARE 18 19 SPARE 1/20 X L70 SPARE 20 21 SPARE 1/20 X 1/20 SPARE 22 23 SPARE 1/20 X 1/20 SPARE 24 25 SPARE 1/20 X 1/20 SPARE 26 27 SPARE 1/20 X 1/20 SPARE 28 29 SPARE 1/20 X 1120 SPARE 30 TOTAL LOAD PHASE 'A' 7218 REMARKS TOTAL LOAD PHASE 'B' 7656 (TC) TIME CLOCK CONTROLLED TOTAL LOAD PHASE 'C' 6720 ( -) VIA CONTACTOR (a or b) (LD) LOCK -ON DEVICE TOTAL LOAD ALL PHASES 21594 WATTS (IG) ISOLATED GROUND 25.99 AMPS (HR) HACR RATED CB (SD) SWITCHING DUTY CB ELECTRIC LOAD TABULATION DESCRIPTION CONNECTED LOAD USE FACTOR DEMAND LOAD LIGH77NG 6.4 1.25 8.0 SIGN 1.2 1.25 1.5 RECEPTACLES 8.0 1.0 8.0 WATER HEATER 1.5 1.0 1.5 R. T.U. 4.5 1.25 x LARGEST CAMP 1 X REMAINDER 4.7 TOTAL 21.6 23.7 AMPS AT 120/208V = / 360 = AMPS AMPS AT 277/480V = 21600 / 831 = 25.9 AMPS GENERAL NOTES (AS APPLICABLE) 1. COMPLETE SYSTEMS: PROVIDE LABOR, MATERIALS, EQUIPMENT AND TRANSPORTATION TO RECEIVE, INSTALL, ADJUST AND PUT INTO OPERA770N COMPLETE ELECTRICAL SYSTEMS IN ACCORDANCE WM7H THE INTENT OF 7HE CONTRACT DOCUMENTS. PROVIDE PRODUCTS NOT MENTIONED BUT OBVIOUSLY NECESSARY AND INCIDENTAL TO THE COMPLETION OF THIS WORK. 2. SCOPE WORK SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING, MECHANICAL WORK AS REQUIRED FOR COORDINATION, POWER DISTRIBUTION, FIRE ALARM SYSTEMS AND INSTALLATION OF MATERIALS. .3. UTILITIES: COORDINATE WITH ALL UTILITY SERVICES NOTIFY UT/LI77ES OF COMMENCEMENT OF WORK MAKE ALL ARRANGEMENTS FOR TEMPORARY SERVCES PROVIDE ALL WORK AND MATERIALS NECESSARY TO COMPLY WITH ALL UTILITY REGULATIONS AND REQUIREMENTS. 4. PERMITS. OBTAIN ALL NECESSARY PERMITS TO BEGIN AND CONTINUE WITH WORK PAY AL ASSOCIATED FEES FOR PERMITS AND OTHER MUNICIPAL AND GOVERNING REQUIREMENTS. 5. EXPERIENCE ALL WORK SHALL BE PERFORMED BY QUALIFIED ELECTRICIANS, UNDER THE SUPERVISION AND DIRECTION OF A SUPERINTENDENT HAVING SUCCESSFUL EXPERIENCE INSTALLING AND SUPERWSING EQUIPMENT AND SYSTEMS OF SIMILAR TYPE AND SIZE AS INDICATED BY CONTRACT DOCUMENTS. 6. REGULATIONS: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT RULES, REGULATIONS AND INDUSTRY STANDARDS OF THE N.E.C., U.L., IPCEA, NEMA, NFPA, OSHA, NA710NAL ELECTRIC SAFETY CODE AND ANY LOCAL CODES, LAWS, ADA, OR ORDINANCES. IN THE EVENT THAT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, 7HE ENGINEER SHALL BE NOTIFIED IMMEDIATELY 7. COSTS AND CONDITIONS: EXAMINE AND BECOME FAMILIAR MPH ALL CONTRACT DOCUMENTS IN THEIR ENTIRETY. SURVEY THE PROJECT AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND SCOPE OF WORK ALL COSTS SUBMITTED SHALL BE BASED ON A THOROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY ADDITIONAL COSTS DUE TO FAILURE TO COMPLY WITH THIS REQUIREMENT SHALL BE 7HE RESPONSIBILITY OF THE CONTRACTOR. 8. SPECIFICA TTONS :: BECOME FAMILIAR WITH ALL SPECIFICATIONS, DESIGN CRITERIA, AND EQUIPMENT REQUIREMENTS PRIOR TO ANY EQUIPMENT PURCHASE OR INSTALLATION. REFERENCE SPECIFICATION FOR DEVICES, MATERIALS, AND WORKMANSHIP REQUIREMENTS. ADDITIONAL REQUIREMENTS ARE GIVEN IN THESE NOTES AND THE DRAWINGS THERE SHALL BE NO DEW/4770N FROM SPECIFICA7IONS WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER. 9. COORDINATION: COORDINATE WORK HIM ALL OTHER TRADES. GIVE SPECIAL CONSIDERA770N TO COORDINATE INSTALLATION OF LIGHTING, SPRINKLER PIPING AND DUCTWORK. COORDINA 7E WALL OUTLET LOCH 710NS KIM MILLWORK COORDINATE WALL SWITCHES WITH DOOR SWINGS VERIFY EXACT LOCATION, COLOR, AND FINISH OF OUTLETS AND DEICES WITH INTERIOR DESIGNER, ARCHITECT OR DESIGNATED TENANT REPRESENTATIVE PRIOR TO INSTALLA 710 N. la PRODUCTS: ALL PRODUCTS SHALL BE NEW SPECIFICATION GRADE. PRODUCTS OF A SIMILAR NATURE SHALL BE OF THE SAME TYPE AND MANUFACTURER. PROVIDE THE STANDARD PRODUCTS OF MANUFACTURERS REGULARLY ENGAGED IN 7HE PRODUCTION OF SPECIFIED PRODUCTS, UNLESS OTHERWISE REQUIRED BY DRAWINGS ALL PRODUCTS SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH NA770NALLY RECOGNIZED AND ACCEPTED STANDARDS AND PROCEDURES. 11. COMPA7IBILITY ALL NEW ELECTRICAL DISTRIBUTION EQUIPMENT SHALL MATCH AND BE COMPA7IBLE WITH EXISTING EQUIPMENT, BY MANUFACTURER, TYPE APPLICATION AND SHORT CIRCUIT RATING. 12. IDEN77FICA LION :• ALL ELECTRICAL DISTRIBUTION EQUIPMENT, TRANSFORMERS, PANEL BOARDS AND OTHER ENCLOSED EQUIPMENT SHALL BE IDENTIFIED AS INDICATED IN THE CONTRACT DOCUMENTS, SAID IDENT1FICA710N SHALL CONSIST OF PERMANENTLY ATTACHED ENGRAVED LAMINATED PLASTIC NAMEPLATES. EACH BRANCH CIRCUIT OVERCURRENT PROTECTION DEICE SHALL BE IDENTIFIED BY CIRCUIT NUMBER AND SCHEDULED INSIDE PANEL DOOR. EACH BRANCH CIRCUIT SPLICE OR 7ERM/NA770N SHALL BE IDENTIFIED BY PANEL AND CIRCUIT DESIGNATION SHOWN ON THE JUNCTION OR OUTLET BOX, OR UPON INDMDUAL WIRES IN CASES WHERE MORE THAN ONE OF EACH PHASE CONDUCTOR OCCUR. 13. WIRING :: ALL CONDUCTORS CARRYING GREATER THAN 50 VOLTS SHALL BE MINIMUM #12 AWG, SOLID, CU SOFT DRAWN OF 98% CONDUCTIVITY, UNLESS NOTED OTHERWISE INSULATION: PROVIDE TYPE THW, THWN, THHN, OR XHHW TYPE INSULATIONS COORDINATE INSULATION TYPES WITH CONDITIONS, N.E.C. REQUIREMENTS AND CONDUIT FILL REQUIREMENTS. ALL WIRING SIZES ARE BASED ON 60 OR 75 DEG. C INSULA710N, ACCORDING TO CURRENT RATING, REGARDLESS OF ACTUAL INSULATION USED. TYPE "AC" OR 'MC" CABLE IS ACCEPTABLE ONLY WITH TYPE THHN INSULA710N. HOME RUNS: PROVIDE MINIMUM #10 AWG WIRING ON ALL HOMERUNS GREATER THAN 100 FEET COLORS: PHASES. 208V WYE 240V DELTA A C BLACK RED BLUE BLACK ORANGE (HIGH LEG) BLUE BROWN ORANAGE YELLOW NEUTRAL WHITE WHITE WHITE w /TRACER GROUND GREEN GREEN GREEN 14. GROUNDING: ALL CIRCUITS SHALL BE RUN WTH #12 A WG INSULATED GREEN COPPER GROUND WIRE, UNLESS OTHERWISE NOTED. USE OF CONDUIT AS A GROUND IS UNACCEPTABLE. AT SERVICE: PROVIDE BONDING JUMPER BETWEEN GROUND BUS AND NEUTRAL BUS. PRCMDE GROUNDING ELECTRODE CONDUCTORS AND GROUNDING ELECTRODES PER NEC. 15. CONDUIT ALL WIRING SHALL BE IN CONDUIT, MINIMUM 1/2" (EM. T IS ACCEPTABLE WITH COMPRESSION FITTINGS ONLY). FLEXIBLE METAL CONDUIT IS ACCEPTABLE ONLY W7H SEPARATE INSULATED GROUND WIRE, AND ONLY FOR SWITCH DROPS OR LIGHTING FIXTURE WHIPS, ENT, ALUMINUM CONDUIT, NM ( "ROMEX'), NM AND SNM ARE NOT ACCEPTABLE. RIGID CONDUIT: CONDUIT OVER 2" IN DIAMETER, OR EXPOSED TO WEATHER, OR EXPOSED TO POIENTiAL DAMAGE, OR USED FOR SERVICE ENTRANCE SHALL BE GALVANIZED RIGID STEEL TYPE. PVC CONDUIT PVC CONDUIT, MINIMUM SCHEDULE 40, IS ACCEPTABLE ONLY FOR USE BELOW GRADE, AND ONLY WHEN INSTALLED WITH WIDE RADIUS RIGID STEEL TURNS. ROUTING: CONDUIT ROUTING SHOWN IS SYMBOLIC AND DIAGRAMMATIC. INSTALL CONDUIT TO FIT ACTUAL FIELD CONDITIONS BELOW GRADE COVER METALLIC CONDUIT BELOW GRADE WITH ASPHALTUM OR BITUMAS77C TAPE. SEAL JOINTS AGAINST WATER. 16. CONDUIT FITTINGS: ALL FITTINGS SHALL BE COMPRESSION OR THREADED TYPE. USE OF SET SCREW FITTINGS IS NOT ACCEPTABLE. 17 CIRCUIT BREAKERS: ALL BRANCH CIRCUIT OVERCURRENT PROIECTiON DEICES SHALL BE 20 AMPERE INVERSE TIME TYPE CIRCUIT BREAKERS UNLESS NOTED OTHERWISE. 120 /240 VOLT CIRCUIT BREAKERS SHALL BE RATED AT 10,000 A/C MINIMUM, MULTI -POLE BREAKERS SHALL BE INTEGRAL UNITS. USE OF HANDLE 71ES IS NOT ACCEPTABLE. 18. FUSES: ALL FUSES 600 AMPERES OR LESS SHALL BE U.L. LISTED CLASS RK1 OR J, LOW -PEAK, DUAL ELEMAENT, TIME DELAY, 600 VOLT ACCEPTABLE MANUFACTURERS: BUSSMAN, GOULD SHAWMUT. 19. PENETRATIONS: ALL PENETRATIONS THROUGH FIRE -RATED SLABS AND PARTITIONS SHALL BE FIRE PROOFED TO THE SAME OR GREATER RATING THAN THAT OF THE SLAB OR PARTITION. WHERE CONFLICTS OCCUR, NOTIFY ARCHITECT OR INTERIOR DESIGNER. 20. ALTERNATES & SUBS77RJ77ONS :: SUBMIT FOR APPROVAL AL TERNA TES OF ALL ITEMS SPECIFIED ON THESE DRAWINGS THE CONTRACTOR SHALL BEAR THE BURDEN OF SHOWING PROOF THAT ALTERNATIVES REQUESTED FOR SUBSTITUTION PERFORM IN AN EQUAL OR SUPERIOR MANNER TO THE SPECIFIED ITEM. INFORMA710N SUBMITTED FOR THE ENGINEER'S CONSIDERATION SHOULD INCLUDE PERFORMANCE CHARACTERISTICS, ILLUS7RA710N OF FIELD APPLICA710N AND COMPARISON OF THE SPECIFIED ITEM TO THE INTENDED ALTERNATE "ALTERNATE" REFERS TO A LUMINAIRE, FIXTURE DEVICE, EQUIPMENT ITEM OR MANUFACTURER OTHER THAN THAT SPECIFIED ON THE DRAWINGS OR IN THE SPECIFICATIONS 21. SHOP DRAWING AND SUBMITTALS.- SUBMIT MANUFACTURERS' STANDARD PRODUCT INFORMATION, PERFORMANCE SPEC/RCA7IONS, PHYSICAL DIMENSIONS AND OTHER INFORMA 170N NECESSARY FOR ENGINEER TO INSURE COMPLIANCE WITH SPECIRCA71ONS ' SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO ORDERING AND INSTALLING ANY EQUIPMENT. 22 PROJECT RECORD DOCUMENTS: UPON COMPLETION OF WORK, PREPARE LIGHTING AND POWER PROJECT RECORD DOCUMENTS ( "AS -BUIL TS ") ON A SUITABLY REPRODUCIBLE MEDIUM (MYLAR OR VELLUM), PRESENT COMPLETED DRAWINGS TO OWNER, AND TWO SETS OF PRINTS TO INTERIOR DESIGNER OR ARCHITECT "AS- BUILT" DRAWINGS SHALL INCLUDE BRANCH CIRCUIT WORK, ANY PANELBOARD INFORMA170N AVAILABLE, FINAL SWITCHING, ETC. 23. WARRANTY: WARRANT ALL MATERIALS, EQUIPMENT, AND INSTALLATION FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY OWNER. GENERAL LIGHTING NOTES (AS APPLICABLE) 1. FIXTURE TYPES: REFERENCE LIGHTING FIXTURE SCHEDULE AND REFLECTED CEILING PLAN FOR COMPLETE DESCRIPTION OF EACH FIXTURE TYPE. LIGHT FIXTURES ARE IDENTIFIED BY LETTERS AND SYMMBOLS. 2. SWITCH LOCA170N5 TYPICAL SWITCHING SHALL BE SHOWN. 3. EXIT SIGNS. FURNISH EXIT SIGNS WITH INTEGRAL 90 MINUTE NICKEL- CADIUM BA I ILRY BASED EMERGENCY POWER SOURCE. 4. EMERGENCY LIGHTING :: SUPPLY EMERGENCY FIXTURES WITH INTEGRAL 90 MINUTE BA I ILRY. 5. FIXTURE LOCATIONS REFERENCE REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF LIGHT RXTURES COORDINATE INSTALLA770N IN FIELD WITH TENANT AND ENGINEER. COORDINATE AIMING OF ADJUSTABLE FIXTURES IN FIELD WITH TENANT 6. INSTALLATION.• WIRE FROM JUNCTION BOXES TO FIXTURES OR SWITCHES AS INDICATED. ADDI770NAL JUNCTION BOXES MAY BE REQUIRED BEYOND THOSE SHOWN 7. SUPPORT ALL FIXTURES ACROSS CEILING TEES OR FROM STRUCTURE ABOVE. IN NO CASE SHALL CEILING TILES OR PLASTER CEILING SUPPORT ANY FIXTURE. 480V GENERAL POWER NOTES (AS APPLICABLE) 1. GENERAL: VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER PRIOR TO INSTALLATION. PROVIDE OUTLET BOXES, DEVICES, COVERPLA7ES AND FLANGES AS REQUIRED. 2. COORDINATION: MOUNT ALL OUTLETS AT 15" A.F.F. UNLESS NOTED OTHERWISE. REFERENCE ARCHITECT'S DRAWINGS, PLANS, & ELEVAl70NS FOR ALL HEIGHTS, DIMENSIONS AND CONFIGURATIONS OF DEVICES NOT INDICATED ON THESE DRAWINGS. REFERENCE SAME DRAWINGS FOR EQUIPMENT NOT IDENTIFIED. 3 CONVENIENCE OUTLETS ALL CONVENIENCE OUTLETS SHOWN SHALL BE NEMA TYPE 5 -20R, SPECIFICATION GRADE (HUBBELL /5352) DUPLEX RECEPTACLES MPH COVERPLATES TO MATCH EXISTING. WHITE COLOR. ACCEPTABLE MANUFACTURERS. HUBBELL LEV4TON PASS & SEYMOUR FLOOR SERVICE BOXES: PROVIDE STEEL CITY CONCEALED SERVICE FLOOR BOXES CONFIGURED AS INDICATED ON PLAN. PROVIDE POWER, COMMUNICATIONS, DATA & SECURITY WHERE SHOW.. PROVIDE' #GAB CAST PRESET FOR WORK IN CONCRETE 4. IG & GFl RECEPTACLES: ALL ISOLATED GROUND DEVICES (IG) AND GROUND FAULT INTERRUPT (GFI) DEVICES SHALL BE RATED 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WMRE. THE GROUND WIRE SHALL BE RUN CON77NUOUS AND UNSPLICED BETWEEN DEVICE AND PANEL GROUND BUS. 0 120V PRI. N EXISTING DISCONNECT SOCKET (EXISTING) METER BY UTILITY CO.) - ISOLATED GROUND RECEPTACLES SHALL BE U.L. LISTED 20 AMPERE (HUBBELL #1G- 5352). GROUND FAULT RECEPTACLES SHALL BE U.L. LISTED, RATED 20 AMPERES (HUBBELL 10E-5362) 5. 5. 77MECLOCKS: PROVIDE EZ CONTROLS 24 -HOUR, 7-DAY TIMECLOCK TO CONTROL SIGNS, LIGHTING AND OTHER CYCLIC LOADS IDEN77FiED BY OWNER'S REPRESENTATIVE. PROVIDE CONTACTORS AS REQUIRED. VERIFY EXACT LOCATION AND WIRING REQUIREMENTS. 6. INSTALLA LION :• DROP FROM JUNCTION BOXES TO DEVICE AS INDICATED. ADDITIONAL JUNCTION BOXES MAY BE REQUIRED BEYOND THOSE SHOWN 7 EQUIPMENT EXPOSED TO WEATHER SHALL BE WEATHERPROOF. SPECIAL SYSTEM NOTES (AS APPLICABLE) 1. TELEPHONE SYSTEM: PROVIDE BACKBOARDS, CONDUITS AND WIRING AND /OR EMPTY CONDUIT WITH PULL STRING (SEE POWER PLAN FOR EXACT LOCATIONS AND REQUIREMENTS) COORDINATE WORK W11N TELEPHONE SUPPLIER. COORDINATE ALL CONDUIT ROUTING WITH FIELD CONDITIONS PROVIDE CONDUIT FOR TRUNKS, PROVIDE CONDUIT FOR RUNS EXPOSED TO WEATHER' OR DAMAGE. 2. TELEPHONE / DATA RECEPTACLES: FURNISH AND INSTALL CONDUITS FROM OUTLETS TO A MINIMUM 6" ABOVE CEILING -FIELD VERIFY EXACT REQUIREMENTS Will! TELEPHONE EQUIPMENT. SUPPLIER AND INSTALLER. CONTRACTOR IS TO FURNISH AND INSTALL CONDUIT PRIOR TO PHONE VENDOR INSTALLATION` DATE 3. FIRE ALARM. VERIFY FIRE ALARM REQUIREMENTS IN FIELD WITH LOCAL AUTHORITY HAVING JURISDICTION. FURNISH AND INSTALL NEW 1N111Al10N AND ANNUNCIAITON DEICES. PROVIDE WIRE AND CONDUIT FOR TYING NEW FIRE ALARM IN177A7ING AND SIGNALING DEVICES TO NEAREST AVAILABLE FIRE ALARM INl 11A 7ING ZONE VERIFY EXISTING FIRE ALARM SYSTEM HAS CAPACITY FOR ADDITIONAL EQUIPMENT PROVIDE ADDITIONAL CAPACITY AS REQUIRED FOR NEW EQUIPMENT MEET ALL A.D.A. REQUIREMENTS. ELECTRICAL RISER DIAGRAM NOTES: 1. TENANT'S ELECTRICAL CONTRACTOR SHALL COLOR CODE FEEDER CONDUCTORS AT TENANT METER CENTER TO DESIGNATE PHASE NEUTRAL AND GROUND. 2. TENANT'S ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT K.A.I. C. RA77NG OF LANDLORD'S DIS1RIBU770N EQUIPMENT. 3. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 10% ( +) BETWEEN PHASES: A /B, B /C, A/C REGARDLESS OF CIRCUITING INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM PRIOR TO INSTALLA 110N OF ELECTRICAL EQUIPMENT 5. TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH A TYPEWRIIILN DIRECTORY FOR ALL ELECTRICAL PANEL. 24V SEC. REAR DOOR PUSH BUTTON. ® 0 0 ®DELI BUZZER SCHEMATIC VERY SCALE: 1/4" = 1' - -0" EXIST 4 #1 /0 THWN, 1 #6 GND IN 2" C LANDLORD'S ELECTRICAL DISTRIBUTION BOARD 277/480 V 3PH 4W SERVICE 0 0 125/3 LEASE LINE "SALES" BUZZER AT CASH WRAP. (1) LIGHTING CONTACTORS - 12 POLE ASCO 917 STANDARD NEMA W 7H MECHANICALLY HELD ASCO 173 REC'D SWITCHES MID. +48" A.F.F. (1 @ PANEL H). ELECTRICAL RISER DIAGRAM NOTE ALL CONDUCTORS SIZED FOR 75 DEGREE C. MASTER LIGHTING SWITCH BANK (1 )No SCALE EXIST 4 #1/0 THWN, 1#6 GND IN2 "C. I EX (3) #1/0 THWN, (1)#6 GND, IN 1 -1/2" C. SALES AREA H -7,9 SALES FLUORESCENTS SALES AREA B- 11,13,15 TRACK LIGHTS ' o' 125A 30A EXIST PANEL H 277/480V 3PH 4W 100A 'b' ��- EX 30AMP DISC. AT VAV -1. VLF CID EX. (3) #10 71114111, (1) 18 GND, IN 3/4" C. V.I.F. EXIST PANEL B 120/208V 3PH 4W 225A /;\ EX (4) #4/0 THWN, (1) #2 GND, IN 2 -1/2" C. V.I.F. TIME CLOCK (24 HR.) CALENDAR TYPE (4 POLE, 40 AMP) (EX) 75 KVA TRANSFORMER (DRY TYPE STEP DOWN FROM 480V TO 208/120V W / #4 GROUND TO BLDG. STEEL PER NEC #250) (1) LIGHTING CONTACTORS - 12 POLE ASCO 917 STANDARD NEMA WITH MECHANICALLY HELD ASCO 173 REC'D 'SWITCHES M7D. +48" A.F.F. (1 @ PANEL B). CEILING LINE REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 2 3 2009 City of Tukwila BUILDING DIVISION., LANDLORD NOTES TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN /DEN17FICAITON NAMEPLATE ON TENANTS MAIN DISCONNECT SWITCH IN LAN RD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE- EIGHTH INCH THICK PLASTIC, BLACK ON WH/ AND ETCHED LETTERS. U M SIZE SHALL BE ONE INCH (1 W M ONLY THE TENANTS SPACE NUMBER ENGRAVED O CH, PERMANENTLY AFRXED. 2. ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE ON BACK WALL FOR TEMPORARY ELECTRICAL FOR CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE 3. LANDLORD PROVIDED DISCONNECT MEANS FOR TENANT IN A LANDLORD ELECTRICAL ROOM AS WELL AS CONDUIT AND CONDUCTORS (EEDER) FROM THE MAIN DISCONNECT MEANS TO A LANDLORD PR VIDEO FUSED DISCONNECT SWITCH LOCATED WITHIN 7HE TENANT SPACE IF NEEDED TO ACCOMMODATE TENANT CONSTRUCTION THE TENANT SHALL RELOCATE 7HE LANDLORD PROVIDED DISCONNECT SWITCH AND ASSOCIATED FEEDER. TENANT SHALL FURNISH AND INSTALL CONDUIT AND CONDUCTORS FROM FUSED DISCONNECT SWITCH TO TENANTS MAIN FUSED DISCONNECT SWITCH OR MAIN CIRCUIT BREAKER EQUIPPED PANELBOARD. LANDLORD NOTES LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROVIDE A COMMUNMCA770NS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY ANY OTHER WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. E DI 2.1 RECEIVED NOV 18 2009 PERMIT CENTER DMC STORE # 4083 RELOCATION ARCHITECT OF RECORD: C O R T L A N D M 0 R G A N ARCHITECT 711 NORTH FIELDER ROAD ARLINGTON, TEXAS 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 I F Q 0 z ° W w ° DRAWN BY: C.M. ELECTRICAL SPEC.'S & DETAILS E1.2