Loading...
HomeMy WebLinkAboutPermit EL09-0737 - MACY'SMACY'S 500 SOUTHCENTER MALL EXPIRED 06 -06 -10 ELO9-0737 City■f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049086 Address: 500 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL09 -0737 Issue Date: 12/08/2009 Permit Expires On: 06/06/2010 Tenant: Name: MACY'S Address: 500 SOUTHCENTER MALL , TUKWILA WA Owner: Name: FEDERATED DEPT STORES INC Phone: Address: ATTN: TAX DEPARTMENT - SHF , 7 W 7TH ST Contact Person: Name: MARTIN DILKS Phone: 206 465 -1549 Address: PO BOX 33524 , SEATTLE WA Contractor: Name: COCHRAN INC Phone: 206 367 -1900 Address: PO BOX 33524 , SEATTLE WA Contractor License No: COCHRI *088JS Expiration Date: 04/11/2010 DESCRIPTION OF WORK: ADDITION OF (2) EXISTSING LIGHT PANELS TO AN EXISTING GENERATOR SOURCE. GENERATOR TO BE RELOCATED FROM BASEMENT TO ROOF. Value of Electrical: NRES: $20,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $520.00 National Electrical Code Edition: 2008 LOSr),_,1 Date: I v - o'D / I hereby certify th ave read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work i be complied with, whether specified herein or not. The granting construction Signature: Print Name: t presume to give authority to violate or cancel the provisions of any other state or local laws regulating f work. I am authorized to sign and obtain this electrical permit. P*1 ()L-- H---/q-A15'64 Date: 7 2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0737 Printed: 12 -08 -2009 Parcel No.: 2623049086 Address: Suite No: Tenant: MACY'S • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.lukwila.wa.us S00 SOUTHCENTER MALL TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL09 -0737 ISSUED 11/20/2009 12/08/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting laws regulating co permit doe' not presume to give authority to violate or cancel the provision of any other work or local the performance of work. Signature: Print Name: P/—UL ThelAJ se. Date: doc: Cond -Elec EL09 -0737 Printed: 12 -08 -2009 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: AO .' ✓QL1 + owit Site Address: 500 Southcenter Mall, Tukwilla, WA 98188 Suite Number: Floor: New Tenant: ❑ Yes ® .. No Tenant Name: Macy's Property Owners Name: Macy's Mailing Address: 3rd & Pine St. Seattle WA 98101 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Douglas Chantry Mailing Address: 3rd & Pine St. E -Mail Address: Douglas.Chantry@macys.com Day Telephone: (206) 506 -7705 Seattle WA 98101 City Stale Zip Fax Number: (206) 506 -7885 ELECTRICAL CONTRACTOR INFORMATION Company Name: Cochran, Inc. Mailing Address: 12500 Aurora Ave. North, P.O. Box 33524 Seattle WA 98133 City State Zip Contact Person: Martin Dilks Day Telephone: (206) 465 -1549 E -Mail Address: mdilks @cochraninc.com Fax Number: (206) 368 -3107 Expiration Date: 04/11/2010 Contractor Registration Number: COCHRI *088JS Valuation of Project (contractor's bid price): $ 20,000 Scope of Work (please provide detailed information): Addition of two existing lighting panels to an existing generator source. This submittal is for plan review only to obtain approval of the proposed modifications prior to submitting for an electrical construction permit. Will service be altered? ® Yes ❑ No Adding more than 50 amps? ❑ Yes ® No Type of Use: Emergency lighting for existing retail space. Type of work: ❑ New ® Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ® Puget Sound Energy ❑ Seattle City Light H \Applications\Forms- Applications On l.inN1-2009 - Electrical Permit Application.doc Page 1 of 2 bh w • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $145.60 (including an attached garage) ❑ Garages, pools, spas and outbuildings $78.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $57.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signatur Print Name: Martin Dilks Mailing Address: 12500 Aurora Ave. No. Date: 11/16/2009 Day Telephone: (206) 465 -1549 Seattle WA 98133 City State Zip Date Application Accepted: it01/019cN Date Application Expires: oU1zolto Staff Initials:A� H:\Applications\Forms- Applications On Line \1 -2009 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049086 Permit Number: EL09 -0737 Address: 500 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 11/20/2009 Applicant: MACY'S Issue Date: Receipt No.: R09 -01956 Payment Amount: $416.00 Initials: WER Payment Date: 12/08/2009 09:05 AM User ID: 1655 Balance: $0.00 Payee: COCHRAN INC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 00541C ACCOUNT ITEM LIST: Description 416.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 416.00 Total: $416.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 12 -08 -2009 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049086 Permit Number: EL09 -0737 Address: 500 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/20/2009 Applicant: MACY'S Issue Date: Receipt No.: R09 -01858 Initials: User ID: Payee: JEM 1165 Payment Amount: $104.00 Payment Date: 11/20/2009 10:36 AM Balance: $416.00 COCHRAN TRANSACTION LIST: Type Method Descriptio Amount Payment Check 18127 104.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 104.00 Total: $104.00 PAYMENT RECEIVE doc: Receiot -06 Printed 11 -20 -2009 • REVISIONS No changes shall b e made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal " may inc`ude additional plan rev revirn REVIEWED FOR COMPLIANC5 WITH NFPA 70 - NEC NOV 3 o 2009 Ud( City of Tukwila BUILDING DIVISION GENERAL NOTES 480Y/277v SERVICE SWITCHBOARD 800A 4 MCC -1 800A ATS • MCC -1A • • 600A 500A - -- - -- --- - -- — 70A INSTALL J -BOX AT INTERCEPTION POINT OF EXISTING FEEDERS (TYP) 1. EQUIPMENT IS EXISTING AND IN PLACE IN THE PENTHOUSE OF THE MACY BUILDING UNLESS NOTED OTHERWISE. 2. ALL NEW WIRE IS COPPER. 3. REFER TO LOAD CALCULATIONS ON SEPARATE 8'h" X 11" WORK SHEET. UTILITY XFMR. 480Y/277v (ROOF) 300kW /375kVA GENERATOR (ROOF) NEW CIRCUIT BREAKER TO BE INSTALLED IN SPARE MCCSTARTER/FEEDER DEVICE COMPARTMENT 2" (4) #2/0, (1) #6 GND 1" (3) #4, (1) #8 GND 2" (4) #2/0• (1) #6 GND • O PANEL EM2 225A MLO 208Y/120v 10K AIC (3 FLR) I 1 • PANEL EM1 225A MLO 208Y/120v 10K AIC (BASEMENT) FILE COPY Permit No. - 37 Plan review approval is subject to errors and omis. Approval of construction documents does not authorize the violation of any a code or orn0e. Receipt of approved F comitions is acknowledged: By Date: 1G),- City Of 1'irkwila BUILDING DIVISION EXISTING TRANSFORMER TO BE RELOCATED FROM BASEMENT XFMR T -EM 45 kVA 480- 208Y/12 G.( 1r•1Gt,E oVel t J r Rf � ‘h 2" (4) #2/0, (1) #6 GND bl>J 5L(421..) D 1 46 4 or- '-'-r 175A 175A} NEW ENCLOSED CIRCUIT BREAKER (TYP) 2" (4) #2/0, (1) #6 GND EXISTING FEEDER, 2" (4) #2/0, (1) #6 GND (TYP) ccc rangy f '0151 Drawn by: Martin A. Dilks, Cochran, Inc. November 16, 2009 Generator System Modifications Macy's — Southcenter Mall 500 Southcenter Mall, Tukwilla, WA 98188 CITY OF Ivuv ? 0 1009 PERMIT CENTER Partial Power One Line Diagram E -1 Macy's Southcenter Emergency Generator Existing Loads MCC -1A Fdr No HP FLA ( Note1) kVA 26 30 40 31.9 27 30 40 31.9 28 25 34 27.1 29 30 40 31.9 30 30 40 31.9 31 40 52 41.4 32 40 52 41.4 MCC -1A TOTAL 237.4 Amps @ 480v 3 -Ph = MCC -1A -1 Fdr No HP FLA ( Note1) kVA 33 10 14 11.2 34 10 14 11.2 35 10 14 11.2 MCC -1A -1 TOTAL 33.5 Amps @ 480v 3 -Ph = Amps 285.6 40.3 TOTAL EXISTING GENERATOR LOAD = 270.9 Amps @ 480v 3 -Ph = 325.8 Added Load Amps (Note 2) kVA Demand Lighting, Panels EM1 & EM2 29 24.1 30.1 kVA TOTAL NEW GENERATOR DEMAND LOAD = Amps @ 480v 3 -Ph = Existing Generator Capacity = 375kVA NEW MCC -1A -1 DEMAND LOAD = Amps @ 480v 3 -Ph = 301.0 kVA 362.1 Amps 63.6 kVA 76.5 Amps Notes 1. Full -Load current per NEC Table 430.250 2. Panels EM1 and EM2 feed existing 120v lighting loads. Loads were recorded by the Owner on the ide of an existing 480v- 208Y/120v step -down transformer while all circuits were fully loaded were turned on). The maximum phase load recorded on the 480v side was 21j V CITY • F LA NOV ? 0 2009 PERMIT CENTER REVIEWED COMPLIANCE FPA 70 - NEC NOV 3 0 2009 City of Tukwila BUILDING DIVISION LO1V1'Y1 • Department of Community Development MARTIN DILKS PO BOX 33524 SEATTLE WA 98133 RE: Permit No. EL09 -0737 500 SOUTHCENTER MALL TUKW Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 06/06/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 06/06/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, <1)10 R..\S_",__ Bill Rambo Permit Technician File: Permit File No. EL09 -0737 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • PERMIT C00RD COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL09 -0737 DATE: 11 -20 -09 PROJECT NAME: MACY'S SITE ADDRESS: 500 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: A-u1� 11—k-I �1 Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-24-09 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required U No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12-22 -09 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: I)oc unients/routing slip.doc 1 -1H -01 Untitled Page • 1 Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company COCHRAN INC 2063671900 PO BOX 33524 SEATTLE WA 981330524 KING Corporation UBI No. Status License No. 578042134 ACTIVE COCHRI`088JS License Type ELECTRICAL CONTRACTOR Effective Date 4/10/1992 Expiration Date 4/11/2010 Suspend Date Specialty 1 GENERAL Specialty 2 UNUSED Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status COCHREC450BK COCHRAN ELECTRIC CO INC ELECTRICAL CONTRACTOR GENERAL UNUSED 1/12/19554/30/1992 01/01/1980 ARCHIVED ADMINISTRATOR INFORMATION License COCHRRL259R2 Name COCHRAN, ROBERT L Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date COCHRAN, ROBERT L Cancel Date 01/01/1980 Bond Amount COCHRAN, GORDON W 01/01/1980 COCHRAN - OLSEN, LEEANN G Until 01/01/1980 COCHRAN, ROBERT L AGENT 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVELERS Until https://fortress.wa.gov/lni/bbip/Detail.aspx 12/08/2009