HomeMy WebLinkAboutPermit EL09-0744 - SAVVIS COMMUNICATIONSSAWIS COMMUNICATIONS
12301 TUKWILA
INTERNATTONAL
EL09 -0744
L
Citygf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
ELECTRICAL PERMIT
Parcel No.: 0923049367 Permit Number: EL09 -0744
Address: 12301 TUKWILA INTERNATIONAL BL TUKW Issue Date: 11/23/2009
Suite No: Permit Expires On: 05/22/2010
Tenant:
Name: SAVVIS COMMUNICATIONS
Address: 12301 TUKVVILA INTERNATIONAL BL , TUKWILA WA
Owner:
Name: INTERNATIONAL GATEWAY WEST Phone:
Address: 12201 TUKVVILA INTERNATIONAL BLVD , SEATTLE WA
Contact Person:
Name: RICK VOGT Phone: 425 766 -3275
Address: 15135 NE 92 ST , REDMOND WA
Contractor:
Name: SEQUOYAH ELECTRIC LLC Phone: 425- 814 -6000
Address: 12316 134 CT NE , REDMOND WA
Contractor License No: SEQUOEL977S9 Expiration Date: 01/29/2011
DESCRIPTION OF WORK:
INSTALL (6) NEW CIRCUITS ON FIRST FLOOR COMM DAGE. INSTALL (4) NEW 20A 120V
CIRCUITS IN SEPARATE COMM CAGE ON FIRST FLOOR. ADD (3) NEW 30 A CIRCUITS ON
SECOND FLOOR. (TOTAL OF 13 CIRCUITS)
Value of Electrical: NRES: $5,700.00
RES: $0.00
Type of Fire Protection: UNKNOWN
Electrical Service provided by: SEATTLE CITY LIGHT
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be co s• •lie
The granting of this per
construction or the
Signature
Fees Collected:
National Electrical Code Edition: 2008
$186.40
Date: l l I n f vi
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
1. es not pres
ance • wor
Print Name:
e authority to violate or cancel the provisions of any other state or local laws regulating
horized to sign and obtain this electrical permit.
Date: // ,3 ✓v7
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
E L09 -0744 Printed: 11 -23 -2009
Parcel No.: 0923049367
Address:
Suite No:
Tenant:
OD •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
PERMIT CONDITIONS
12301 TUKWILA INTERNATIONAL BL TUKW
SAVVIS COMMUNICATIONS
Permit Number:
Status:
Applied Date:
Issue Date:
EL09 -0744
ISSUED
11/23/2009
11/23/2009
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit • •es of presume to give authority to violate or cancel the provision of any other work or local
laws regulating construe •n o the perfor ance of work.
'
Signature: ( / i� Date: // —�3 -
Print Name:l�l� �l
doc: Cond -Elec
EL09 -0744
Printed: 11 -23 -2009
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.citukwila.wa.us
Electrical Permit No.
Project No.
(For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.:
0g 7.-01-1
1
Site Address: 12 So 1 TUr-101 LA 1MT END Suite Number: Floor:
Tenant Name: J P U V I S 1(-1.6t +/ 1 )J S New Tenant: ❑ Yes Tlo
Property Owners Name: pi E f-1-1 P
Mailing Address:
City
State
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: «k `JOG 1
Mailing Address: 15 1 S NYC c(1
E -Mail Address:
Day Telephone:
o- 0 cAA
City
i- O?
State Zip
Fax Number:
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person:
SzquoyAl-1 E''LFe
i5LL5 Ns Q2Ubo sue"
c}- LJ T
EO rvlo L)�
to
E -Mail Address: 1('1 c L.. EC?(JOy )-4 , (_� •
Contractor Registration Number: SU aE L— 7 7 S �]
City State Zip
Day Telephone: L/2, ~ %6L0 _ 3Z7 S
Fax Number:
Expiration late:
Valuation of Project (contractor's bid price): $ S 700
Scope of Work (please provide detailed information):
irvsfiiA (i
c c.. e /kJ S f-� /1 4 ,vex,.) 2v A 120 (/
'°
, A S kpaLQ �O rA
(3 r—kTS
('
c 1 i c.. i+-s 6 iv t s T Ft-2 ct vt rv\
GkTr, /4') SEPTe ATr !COL/4I4L Ci: eye bn
-e - n �, �/! PZ 7-t -,
c7TA
L
s�
Will service be altered? ❑ Yes T No Adding more than 50 amps? ❑ Yes
Type of Use: •
Type of work:
❑ New ❑ Addition ❑ Service Change
❑ Low Voltage ❑ Generator ❑ Fire Alarm
Property Served by:
❑ Puget Sound Energy
gSeattle City Light
H:\Apphcations \Forms - Applications On Line \I -2009 - Electncal Permit Applicanon. doc
bh
❑ Remodel a Tenant Improvement
❑ Telecommunication ❑ Temporary Service
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings ... .$145 60
(including an attached garage)
❑ Garages, pools, spas and outbuildings $78.00 ea
❑ Low voltage systems
(alarm, furnace thermostat) $57.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $78.00
(no added/altered circuits)
❑ Service change with added/altered circuits $78.00
number of added circuits $1 1.00 ea
❑ Circuits added/altered without service change $52.00
(up to 5 circuits)
❑ Circuits added/altered without service change $52.00
(6 or more circuits) $7.30 ea
❑ Meter /mast repair .. .......... $65 00
❑ Low voltage systems $57.00
(alarm, furnace thermostat)
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $60.00
❑ Temporary service (generator) 575.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER !..f CTRICAL, ONTRACTOR:
/ 4;1*
Signature: _
Print N. e: 66-6 U47—
Mailing Address: /5/ (97"' / r749/})(%Y/'
Date: //),?d
Day Telephone: L/Z5 ' 766 - 32 7_5"
Grp' 97 5 Z
City State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H VAppli cations'Tarms- Applications On Une11 -2009 - Eleciricai Permit Application doc
bh
Page 2of2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 0923049367 Permit Number: EL09 -0744
Address: 12301 TUKWILA INTERNATIONAL BL TUKW Status: PENDING
Suite No: Applied Date: 11/23/2009
Applicant: SAWIS COMMUNICATIONS Issue Date:
Receipt No.: R09 -01877
Initials:
User ID:
Payee:
JEM
1165
Payment Amount: $186.40
Payment Date: 11/23/2009 12:06 PM
Balance: $0.00
SEQUOYAH, LLC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 523560 186.40
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.00 186.40
Total: $186.40
PYMENT
RECEIVE
doc: Receipt -06 Printed: 11 -23 -2009
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
6.01 PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
T N0.
R.. 4--
(206)431 -3670
Project: 541/IA Cctf
Type of Inspection: �3
Address:
Date Called:
Special Instructions:
Date Wanted:
1 ki(5.0'
p.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
OMMENTS:
Inspector:
Date: #5/07
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
Untitled Page
•
•
Page 1 of 2
Electrical Contractor
A business licensed by LQJ to contract electrical work within the scope of its specialty.
Electrical Contractors must maintain a surety bond or assignment of savings account.
They also must have a designated Electrical Administrator or Master Electrician who is a
member of the firm or a full -time supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
SEQUOYAH ELECTRIC LLC
4258146000
15135 NE 92ND ST
REDMOND
WA
98052
KING
Limited Liability Company
UBI No. 602252591
Status ACTIVE
License No. SEQUOEL977S9
License Type ELECTRICAL CONTRACTOR
Effective Date 1/29/2003
Expiration Date 1/29/2011
Suspend Date
Specialty 1 GENERAL
Specialty 2 UNUSED
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
RAINIEC066MG
RAINIER
ELECTRICAL
CONTRACTORS
ELECTRICAL
CONTRACTOR
GENERAL
UNUSED
7/7/1994
7/7/1996
ARCHIVED
RAINIEC121MG
RAINIER
ELECTRICAL
CONTRS INC
ELECTRICAL
CONTRACTOR
GENERAL
UNUSED
7/7/1988
7/7/1994
ARCHIVED
SEQUOC *062Q8
SEQUOYAH
CORPORATION
ELECTRICAL
CONTRACTOR
GENERAL
UNUSED
11/28/1994
11 /28/2004
EXPIRED
JAMESEL98ORD
JAMESTOWN
ELECTRIC LLC
ELECTRICAL
CONTRACTOR
GENERAL
UNUSED
12/4/2002
12/4/2004
OUT OF
BUSINESS
MASTER ELECTRICIAN INFORMATION
License NICHODE97406
Name NICHOLS, DAVID E
Status ACTIVE
Business Owner Information
Name
Role
Effective Date
Expiration Date
NICHOLS, DAVID E
PARTNER /MEMBER
01/29/2003
https://fortress.wa.gov/lni/bbip/Detail.aspx
11/23/2009