Permit EL09-0793 - SABEY CORPORATION - BUILDING B
SABEY CORPORATION 12201 TUKWILA INTERNATIONAL BL EL09 -0793 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 0923049120 Permit Number: EL09 -0793 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Issue Date: 01/04/2010 Suite No: Permit Expires On: 10/21/2010 Tenant: Name: SABEY CORPORATION, BLDG B Address: 12201 TUKWILA INTERNATIONAL BL , TUKWILA WA Owner: Name: INTERNATIONAL GATEWAY WEST Phone: Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA Contact Person: Name: DREW MACKEY Phone: 206 - 774 -1356 Address: 3623 EAST MARGINAL WAY S , SEATTLE WA Contractor: Name: EVERGREEN POWER SYSTEMS INC Phone: 206 774 -1400 Address: 3849 1 AV S , SEATTLE WA Contractor License No: EVERGPS950BE Expiration Date: 01/05/2011 DESCRIPTION OF WORK: MOVE THE BUILDING FEED OFF OF THE 2000 KVA TRANSFORMER AND FEEDING IT FROM THE NEW 2500 KVA SCL TRANSFORMER. RE -FEED EXISTING ELECTRICAL SWITCH GEAR. NO ADDED LOAD. REVISION #1: INSTALL 1200A SERVICE TO BUILDING B. REPLACE BREAKERS AND PANEL INTERIORS IN PANELS H1, H3, AND H4 TO MEET REQUIRED AIC. Value of Electrical: NRES: $78,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied The granting o construction Signature: this p the p rmit does not rformance of xami with Fees Collected: $1,915.00 National Electrical Code Edition: 2008 Date: O l 6 i� ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. esume to ork. I am a authority to violate or cancel the provisions of any other state or local laws regulating ized to sign and obtain this electrical permit. Print Name: 0l`"t1/1% Mr1 Date: tt.) /ti`' /° This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0793 Printed: 05 -04 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /wwwci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 0923049120 Permit Number: EL09 -0793 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Issue Date: 01/04/2010 Suite No: Permit Expires On: 07/03/2010 Tenant: Name: SABEY CORPORATION Address: 12201 TUKWILA INTERNATIONAL BL , TUKWILA WA Owner: Name: INTERNATIONAL GATEWAY WEST Phone: Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA Contact Person: Name: DREW MACKEY Phone: 206 - 774 -1356 Address: 3623 EAST MARGINAL WAY S , SEATTLE WA Contractor: Name: EVERGREEN POWER SYSTEMS INC Phone: 206 774 -1400 Address: 3849 1 AV S , SEATTLE WA Contractor License No: EVERGPS950BE Expiration Date: 01/05/2011 DESCRIPTION OF WORK: CURRECTLY THE BUILDING AND DATA CENTER ARE BOTH FED FROM A 2000 KVA SCL TRANSFORMER. WE WILL BE MOVING THE BUILDING FEED OFF OF THE 2000 KVA TRANSFORMER AND FEEDING IT FROM THE NEW 2500 KVA SCL TRANSFORMER. RE -FEED EXISTING ELECTRICAL SWITCH GEAR. NO ADDED LOAD Value of Electrical: NRES: $40,000.00 Fees Collected: $930.00 RES: $0.00 Type of Fire Protection: UNKNOWN National Electrical Code Edition: 2008 Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Date: LI— (� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied w'th, whether specified herein or not. The granting o construction o Signature: rmit does not p rformance of sume to rk. I am a authority to violate or cancel the provisions of any other state or local laws regulating ed to sign and obtain this electrical permit. Print Name: V1 161" 4-4t k \ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: i' 1 I doc: EL -4107 EL09-0793 Printed: 01 -04 -2010 Parcel No.: 0923049120 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 12201 TUKWILA INTERNATIONAL BL TUKW SABEY CORPORATION Permit Number: Status: Applied Date: Issue Date: EL09 -0793 ISSUED 12/11/2009 01/04/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not .resume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the erformance of work. Signature: Print Name: C" Date: ( doc: Cond -Elec EL09 -0793 Printed: 01 -04 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit N t No. ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 12201 TUKWILA INTERNATIONAL BLVD Tenant Name: SABEY CORPORATION Property Owners Name: SABEY CORPORATION Mailing Address: 12201 TUKWILA INTERNATIONAL BLVD King Co Assessor's Tax No.: Cq,.L -3044 9 10)--0 Suite Number: Floor: 4 New Tenant: ❑ Yes .. No TUKWILA WA 98168 City State Zip CONTACT PERSON - ontact when your permit it ay to be issued Name: DREW MACKEY Mailing Address: E -Mail Address: dmackey @evergreenps.net 3623 EAST MARGINAL WAYS SOUTH Day Telephone: SEATTLE City State Fax Number: (206) 774 -1401 (206) 774 -1356 WA 98134 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: EVERGREEN POWER SYSTEMS, INC. Mailing Address: 3623 EAST MARGINAL WAYS SOUTH SEATTLE WA 98134 City Contact Person: JUSTIN BRANSON Day Telephone: E -Mail Address: Jbranson @evergreenps.net Fax Number: Expiration Date: Contractor Registration Number: EVERGPS950BE State (206) 774 -1359 (206) 774 -1401 01/05/2011 Zip Valuation of Project (contractor's bid price): $ 40,000 Scope of Work (please provide detailed information): Job #2297. Currently the building and data center are both fed from a 2000 KVA SCL transformer. We will be moving the building feed off of the 2000KVA transformer and feeding it from a new 2500 KVA SCL transformer. Re -feed existing electrical switch gear. No added load. Will service be altered? ® Yes ❑ No Adding more than 50 amps? ❑ Yes ® No Type of Use: COMMERCIAL OFFICE BUILDING Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy ® Seattle City Light ® Service Change ❑ Fire Alarm H: Applications \Forms- Applications On Line`.I 2009 - Electrical Pernit Application.doc bh ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $145.60 $78.00 ea .$57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) 57.30 ea ❑ Meter /mast repair 565.00 ❑ Low voltage systems $57.00 (alarm, fumace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT MPPLKCAflON NAVES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE _ ' BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. B ILDING OW ER OR : LECTRICAL CO 'TRACTOR: WINE— Mailing Address: 3623 EAST MARGINAL WAY S•UTH Signature: Print Name: MACKEY Date: 12/11/2009 Day Telephone: (206) 774 -1356 SEATTLE WA 98134 City State Zip Date Application Accepted: { 101.-- 1 1 _Q a! Date Application Expires: L-tk1v Staff Initials: H: Applications Forms- Applications On Line I -2004 - Electrical Permit Application.doc bh Page 2 of 2 Parcel No.: 0923049120 Address: Suite No: Applicant: SABEY CORPORATION, BLDG B City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 14100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT 12201 TUKWILA INTERNATIONAL BL TUKW Permit Number: Status: Applied Date: Issue Date: EL09 -0793 ISSUED 12/11/2009 01/04/2010 Receipt No.: Initials: User ID: R10 -00768 JEM 1165 Payment Amount: Payment Date: Balance: $625.00 05/04/2010 02:56 PM $0.00 Payee: EVERGREEN POWER SYSTEMS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. 7718 625.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 ELECTRICAL PLAN - NONRES 000.345.832.00.00 Total: $625.00 500.00 125.00 PAYMENT RE(FIVED doc: Receiot -06 Printed: 05 -04 -2010 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http://www.ci.tulcwila.wa.us RECEIPT 0923049120 12201 TUKWILA INTERNATIONAL BL TUKW SABEY CORPORATION, BLDG B Permit Number: Status: Applied Date: Issue Date: EL09 -0793 ISSUED 12/11/2009 01/04/2010 Receipt No.: R10 -00678 Initials: User ID: Payee: WER 1655 Payment Amount: Payment Date: Balance: $360.00 04/21/2010 11:52 AM $0.00 DREW MACKEY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 05517D 360.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 Total: $360.00 360.00 PAYMENT RECEIVED doc: Receipt-06 Printed: 04 -21 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www. ci. tukwila. wa. us RECEIPT Parcel No.: 0923049120 Permit Number: EL09 -0793 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 12/11/2009 Applicant: SABEY CORPORATION Issue Date: Receipt No.: R10 -00004 Payment Amount: $744.00 Initials: WER Payment Date: 01/04/2010 11:36 AM User ID: 1655 Balance: $0.00 Payee: EVERGREEN POWER SYSTEMS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 007230 744.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 744.00 Total: $744.00 PAYMENT RECEIVED rinr. . Rr:r•aint -OR Printed• 01 -04 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us RECEIPT Parcel No.: 0923049120 Permit Number: EL09 -0793 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 12/11/2009 Applicant: SABEY CORPORATION Issue Date: Receipt No.: R09 -01984 Payment Amount: $186.00 Initials: WER Payment Date: 12/11/2009 10:16 AM User ID: 1655 Balance: $744.00 Payee: EVERGREEN POWER SYSTEMS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 007161 186.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 186.00 Total: $186.00 PAYMENT RECEIVED doc: Receipt -06 Printed: 12 -11 -2009 INSPECTION RECORD Retain a copy with permit ELM` 0713 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: cpRe. Type of Inspection: 2100 Address: Ia°1 T•%•g• Date Called: Special Instructions: 2,64, ZS'S' /110 f) _ , (OOINI Date Wanted: 5105— a:m: Requester: Phone No: rA. Approved per applicable codes. EiCorrections required prior to approval. COMMENTS: rowal�5 ►1� Inspector: Date: or Q ri $60.00 REINS ECTION FEE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: INSPECTION RECORD Retain a copy with permit INSPECT N NO. P RMIT N CITY OF TUKWILA BUILDING DIVISION IQ, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 46 Project: 6661 Type of Inspection: 7002, Address: /22z) 1- 0 , Date Called: Special Instructions: Date Wanted: y a.nt, c�- Requester: travict -t_3 - Ups Ji c,,f c 6c-5 rimr Phone No: Approved per applicable codes. 0 Corrections required prior to approval. ,COMMENTS: OK- - GlZ JIC-f i\loic-C44446 (CL • m Vo Ar travict -t_3 - Ups Ji c,,f c 6c-5 rimr fr b, hDb I T A-1, 51-4-VI cf, Inspector '7 Date: l ioZS to El $60.00 REINSPECTION FEE REQUIRED. Prior to inspec n, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit RMIT NO. 0 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: (pit?. Type of Inspection: 7002 Address: Date Called: Special Instructiohs: Date Wanted: C"` p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Date: 0 5 10 El $60.00 REINSPECTION FEE REQU RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit E�dl 0713 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IF' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Cos D. Type of Inspection: QD Addre Date Called: Spec al Instructions: Date Wanted: . 2/ a.r C... Requester: d Phone No: 0 Approved per applicable codes. /—. 0 Corrections required prior to approval. 1 COMMENTS: 174 �l - - 10 roKll 1) co cK Fk SeGicE (alw,*5 M.onIG) WEST i.J9r(A/ Inspector: Date: 02 0 2 I to ins ecti n fe must 0 $60.00 REINSPEbTION FEE REQUIRED. Prior p be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPE(1TION NO. INSPECTION RECORD Retain a copy with permit 6 OZP MIT i0es" (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: 5 (siz_D • Type of Inspection: 7oo/Adress 1ZZo1 7".1•Q• Date Called: .... Special Instructions: Date Wanted: % m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. --� COMMENTS: D, 4. - JnJ�RI,Q,oJr�D 10 x ,5tc.04).#1 roAMdirS 56t, thOLIT TIN F2 Date: 0 r ZV I o ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: REIMBURSEMENT AUTHORIZATION AND APPROVAL TO CONDUCT INSPECTION ACTIVITIES DURING OFF HOURS Date: ©1'1 /Z i (ID Permit No. Ea— Dcl Requested by: ` j Zh,) M ACXNt Firm/Company: . L " V 1 44 �c�1 `��,r� - S�-jS l^-►S Project Name: Project Address /Location: �'� b \ ; r1 W�4 4 1 A'1 0 ?LA Time of Off -Hours Construction Activity — From: 2 ' .D am/6 To: 5 am/69 Requested Date of Inspection: 01-1 Zr-( Contact Name: /v Requested Time: Phone No. 2 am /& Special Conditions for Consideration: ** Contractor will be charged a minimum of four (4) hours inspection time for any off -hours inspection work at $90.00 per hour. This is to be paid at time of request. ** The undersigned, as an authorized presentative of the above firm, hereby agrees to reimburse the City for its overtime inspect • ns excess of four ) ho s. n the above - ferenced pro ct. A separate invoice will be issued for all inspection time in Signature: Print Name: SZ- CITY OF UK KWtUt APR 21 2010 PERMIT CENTER Reviewed by: Approved: Remarks: dy 22/G/6 Disapproved: W:\Permit Ccnter \Templates \Forms\After Hour Inspection Request.doc PERMITCOORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL09 -0793 DATE: 04/19/10 PROJECT NAME: SABEY CORPORATION, BLDG B SITE ADDRESS: 12201 TUKWILAINTERNATIONAL BL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # after Permit Issued DEPARTMENTS: A-g(A11201t Buildin'g`Division Public: Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04/20/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required n No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 05/18/10 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 MING SLIP ACTIVITY NUMBER: EL09 -0793 DATE: 12 -11 -09 PROJECT NAME: SABEY CORPORATION SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: A iv � t�1 Building ision Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-15-09 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -12 -10 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PROJECT NAME: ei SITE ADDRESS: 122-01 '110 PERMIT NO: ad) .0.117" ORIGINAL ISSUE DATE: a t 1 1 ',O REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS p t It) Received by: Received by: V' 011 t? fns Summar of Revision: 13 ':r...: _ ' . G" -' 1 la 1, . Av it 'C U i.-G: ' g" if ,0 j ` Nri r L Received by: 'DREW MAce -1 REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Received by: ease print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: ease print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: ease print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: ease print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: D.....i..e.i r..,. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 04/19/10 Plan Check/Permit Number: ELE09 -0793 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: SABEY TRANSFORMER Project Address: 12201 TUKWILA INTERNATIONAL BLVD - BUILDING B Contact Person: JUSTIN BRANSON Phone Number: (206) 774 -1359 Summary of Revision: Install 1200A service to building B for future tenant build -out. Replace breakers and panel interiors in panels H1, H3, and H4 to meet required AIC. Added Value of Work - $38,000.00 192014 Sheet Number(s): El .P2 & E5.00 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: j�`' Entered in Permits Plus on I{: Applications`Forms- Applications On Line \2009 -08 Revision Submittal.doc Created: 8 -13 -2004 Revised: 8 -2009 Untitled Page Page 1 of 2 Electrical Contractor A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company EVERGREEN POWER SYSTEMS INC 2067741400 3623 E MARGINAL WAY S SEATTLE WA 98134 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602451324 ACTIVE EVERGPS950BE ELECTRICAL CONTRACTOR 1/5/2005 1/5/2011 GENERAL UNUSED ADMINISTRATOR INFORMATION License MACKEJE216JN Name MACKEY, JAMES E Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HOPKINS, JAMES AGENT 01/05/2005 Bond Amount MACKEY, JAMES E PRESIDENT 01/05/2005 52BSBFC2870 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 52BSBFC2870 01/03/2009 Until Cancelled $4,000.00 12/19/2008 https://fortress.wa.gov/lni/bbip/Detail.aspx 01/04/2010 1 2 3 4 5 00000 99999 UILDING 'A' ARLES BY a * -- \ 2 1 00 99 o_ V) L CL uJ >-- uJ (f) 0) CN Ld DC 0 (f) z ft Lai CO (I) 0) CN (f) 0 1_1_1 --) 0 (1) a_ uJ (1) a_ uJ uJ LL OE. PAD °UNTIED SVATCHG (2) LOCATIONS PE UIILITI REQ. RE 4 TO D AIL 1 SHEET EO.3, DI T LOCATOR VATIf UP TO R UP NOD RM, EFER SHEE ,.-( STUB PINS VAULT RM, RE SHEET E3.1_, (3) .1," r1401.1 21sp --FIN' MEV/ TELEPHONE ROOM TG: EAST PROP-UNr" FOUNDABGN:""DOORDI ATE ...-117H EST (TYP) UTILITY 4ANH0LE (POVER) 8'X 113 FI'D PER UTILITY REO. REFER TO DETAIL I SHEET E.B3 .....- .....-- ES1 575LA VAULT KM MARKER TAPE —\\\ FINISHED GRADE TO UPPER SITE LIGHTING Ar STU IVISI MARKER TAPE --\\ T 12- MIN. 7 vr ■t" Y./ EXTEND DUCTBANK 440 PROPERTY UNE, COORDINATE EXACT LOCATION NTH SCL UTILITY FOR CONNECTION_„.......-- TO UTIUTY UNDERGROUND DUCTBANK. (2) S1thNDUIT dig SHALL OE.J10UTD ALONG SIDE-DUCT BANWAT PROPERTUNE CAPPED SEALED FOR FUTURE ACCESS 6g$51.111E1TY TO FUTURE UNDERGROUND ^."" UTIUTY CORRIDOR l'114S11ED GRADE CONCRETE ENVELOPE 30001 MIN, 38- MIN. f4 TIE VA 18" ON DUCT, 4.1T SPARE RACEWAY 4•I CONDUIT WITH CONUCT= (RACEWAY 11 SHOWN) (RACEWAY 11 PENN) SECTION FACING NORTH NOT TO SCALC. 4 IN. AT /TIER •4 REBAR CONTINUOUS TCP & BOTTOM AT EA. cdRNER & AT 24 ON CEN MARKER TAPE 12- MIN. 7 1/2" do° FINISHED GRADE 38' MIN. 4' MIN. #4 TIE WIRE AT 18" ON CENTER DUCT, TYP #4. REBAR CONTINUOUS TOP & BOTTOM AT EA. CORNER & AT 24"MAX ON CENTER LCONCRETE ENVELOPE 30001 MIN. 4•17 SPARE RACEWAY 0 .4 4'R UNMET %MTH CINDUCTLIRS (RACEWAY # SHOWN) (RACEWAY # SHEIWID •SECTION FACING WEST •. or TO SCALE • MARK TAPE FINISHED GRADE 12' MIN. _L_ 7 1/2' L CONCRETE ENVEL 30001 14114. T 4* MIN. #4_11E WRE AT 18" ON CENTER TYP REBAR CONTINUOUS TOP & 001701A AT EA. CORNER DPE & AT 241Aftac. ON CENTER 4•R SPARE RACEWAy C) • 4'R CONDUIT WITH CONDUCTORS (RACEWAY it SHOWN) (RACEWAY U SHOWN) SEPARATE PERMIT REQUIRED FOR: tt Mechanical 0 Electrical 14 Plumbing Gas Piping City of Tukwila BUILDING DIVISION TOP SPARE— PRIMARY-.- FU AND SCL 3 40 50 TOP RE BUILDING 'B' CABLES BY SPARE PRIMARY SECTION FACING NORTH • rt;N\ MANH LE FOLDOUT NOT TO SCALE • . • NOT TO SC. LE • VACEVA SE (.3TION FACING WEST NO U 0 SCALE TOP SPARE PRIMARY, 71 12' MIN. L .1.-■•■■•• 7 1/2 MARKER TAPE --\\ #4 OC+1111UOUS TOP & BOTTOM AT EA. CORNER CONCRETE ENVELaPE & AT 2411AX 3D0041 MIN. ON jENTER 71i SCALE: 1" = 60' FINISHED GRADE M N. 4' MIN. 14 11 WIRE AT 18" ON CENTER UCT, e t T, TYP AR 36" MIN. 4 MIN. •4 11E NIRE AT 18" ON CENTER DUCT, TYP SECTION FACING NORTH ES NOT 10 SCALE SITE - POWER PLAN 6-4"C. 500AL 4'R CONDUIT WITI4CLINDUCTEIRS (RACEWAY SHOwN) REBAR CONTINUOUS 117P & BOTTOM AT EA. CORNER & AT 24"MAX ON CENTER CONCRETE ENVELIPE 30001 MIN, c: SPARE RACEWAY (RACEWAY # S80WN) 471 COULD %MTH CONDUCTORS (RACEWAY SHOWN) „wa PAD (2) 4"c. PRIMARY 77LA 99 "c. TO 2500A 3 MCM AL 1-oo MCM AL L PAD L COLLECTOR BUS (2) 4"c. PRIMARY ELECTRICAL DETAI ELECTRICAL DETAIL REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. IMISS a S711. W.{ AP. NM. OHP UNDERGROUND STORM DRAIN L NE By WATER LINE Date: FUEL LINE FIBER OPTICS CONDUIT PROPERTY LINE ROCKERY UNIT MASONRY RETAINING WALL OVERHEAD POWER LINE EDF 'F COMPLIANCE WITH NFPA 70 - NE MAY 03 2010 FELE CI.PY Permit No. ft-i Plan review approval is subject to errors and o Approval of construction documents does not the violation of an adopted co e or ordinance of approved Fi d py and • ndItio is ackno City Of lUcwIIa BUILDING DIVISION erryR o LA APR '1 9, 2010 PERMIT CENTER N lesions. Adze Receipt ledged: SABEY TRANSFORMER INTERNATIONAL GATEWAY CORPORATE PARK Building B 12201 Tukwila International Blvd Tukwila, WA 98168 _I EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering Revisions No: Item: Plot Pate: Drawn By: MRP Checked By: JB Arch. Bckgrnd.: Title Sheet : 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774-1400 Fax: (206) 774-1401 1 PERMIT SET 12/03/09 2 PERMIT #ELE09-0793 REV 1 04/15/10 10/18/09 Dote: Project Number: 2297 04/16/10 - 12:34pm Drawing Nome: 2297-SABEY TRANS SITE.dwg SITE POWER PLAN PERMIT SET R"VISIOK NO1 1 4-.L II ,. 019 E1000 Q W 0 0 N w 0 0 0 U 0 W (f) 0 Li. HP /10 EF -2 & EF -3 STACKED RISER PANEL 'LP' LIGHTING CONTROL 'LCG' -PANEL 'HP' 31 WP / \ L ELEVATOR LORRY 2 LP/29,31 EWH STAMWAY CD PARKING LEVEL P2 - POWER PLAN SCALE: 1/8" = 1' - 0" LP /6 "-COMM (5)4 "C. TO ELEC. ROOM CR DATA 3/4 "c. 3/4 "c. EWH 3/4 "c. J -BOX FTO REFEED - EXISTIN SERVICE 1 6 E1 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC HP /10 MAY 032010 City of Tukwila BUILDING DIVISION EF -4 & EF -5 STACKED ELO TO SCL XFMR CITY APR "1.9, 2010 PERMITCE REVISION NCt "793 SABEY TRANSFORVIER INTERNATIONAL GATEWAY CORPORATE PARK Building B 12201 Tukwila International Blvd Tukwila, WA 98168 EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Revisions No: Item: PERMIT SET Protect Number: Plot Date: Drawn By: PERMIT #ELE09 -0793 REV 1 04/15/10 Checked By: JB Arch. Bckgrnd.: 10/18/09 2297 04/16/10 - 12:33pm MRP Drawing Name: 2297 -SABEY TRANS P2.dwg Title : Date: 12/03/09 PARKING LEVEL P2 POWER PLAN Sheet : E1.P2 EXISTING SCL 2000 KVA XFMR SCL EXISTING 577LA SPLICE VAULT. CONDUCTORS TO BE ABANDONED NOTE: THE INTENT IS TO HAVE A SEPARATE XFMR FEED EACH SERVICE. EXUSTING SERVICE 2nd FLOOR DATA CENTER SECONDARIES SPLICED IN 712LA VAULT BY SCL V629 (EXISTING) CT l|ST 277/480/3 DIST2 NOT USED MSB REPLACE BREAKERS AS REQUIRED T0 MEET REQUIRED AIC. REMOVE FEED BREAKER AND FEEDER. PANEL TO BE ABANDONED. NOTE: #4 FOOTING GROUND, WATERPIPE & BUILDING STEEL, 2 GRND RODS. #2 RISER FROM SERVICE GROUND THROUGH ELEC. CLOSETS. 1 800/3 SUBMAIN 1 225/3 HP 2 13 ELEV. 2 125/3 AHU-1,4 2 200/3 AHU-2,3 (SPACE ONLY) ( PROV ,u. 1�0D /�vu DIST1 32,000 AIC 0S S T7 ��T1 DIST2 '`�. _-� 277/480/ 117 MCA AHU-4 1 1/4"c. 3#1 200A 200A ] . 1 1 1/4 3�1/0 � '� H1,H2,H3,H4 ( 1 ) 1200 / 3 MDP 3rd FLOOR CT Y�OD ��"" 3_75O,5O0N AL /?\2,w/ 4-4/0 225 MLO HP .GROUND TO REBAR 8c BUILDING STEEL R ''[\|/\ G[l A\/ TOTAL TOTAL 150 MCB LP 117 MCA AHU-1 200 WCB DIST 200A Description 1 ()4"C J- 2 /- MSB-2 INTERGATE WEST BUILDING 'B' 12201 TUKWILA INTL BLVD SEATTLE, WA 2600A BUILDING SERVICE EXISTING DEMAND LOAD (SCL) FUTURE DEMAND FLOOR 3 FUTURE DEMAND FLOOR 1 145 MCA AHU-2 RTU O. 350N CU PROVIDE #2 GRND RISER FROM SWBD THRU EACH ELEC RISER CLOSET. 125A ST 732,600 100,000 797,000 2000A 2nd FLR DATA CENTER SERVICE CURRENT LOAD 513,000 FUTURE DEMAND LOAD 513,000 NOT USED FUTURE 1.00 1.00 1.00 FUTURE (2)2"w/ 4-3/0 cu FUTURE 3#3 ELEV FUTURE LOAD SUMMARY 732,600 100,000 797,000 1.00 513 1.00 513 0 0 0 0 0 0 0 O 0 O O 0 0 0 O 0 0 100% 100% 100% 10096 100% 100% 100% 10096 100% 100% 10096 10096 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% ELEV F-4 P-1 10/18/09 Voltage: 480 Ph: 3 Area/Amps Factor Watts Factor Total Factor TOTAL AMPS 732,600 100,000 797,000 0 0 0 0 0 0 0 0 0 0 513,000 513,000 0 0 0 0 0 0 0 ROOF F-3 REVIEWED Fdli COMPLIANCE WITH NFPA 70 - NEC City of Tukwila BUILDING DIVISION 100% 100% 100% 10096 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%. SCL T MAY 03 20 NEW SCL 2500 KVA XFMR 732,600 100,000 797,000 0 0 0 0 0 0 0 0 0 0 1,629,600 882 120 960 0 0 0 0 0 � 0 0 0 0 0 1,962 513 818 513.000 618 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1,026,000 1,236 CKT NO 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 ` 31 33 35 37 39 . 41 CKT NO 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING ACCESSORIES P-1 P-1 P-1 P-1 F-1 F-2 F-3 F-4 ROOF ACCESSORIES LIGHTING P-2 ELEVATOR RECEPTACLES P-1 FACP F-1 FACP F-2 FACP F-3 FACP F-4 RECEPTACLES F-1 RECEPTACLES F-1 RECEPTACLES F-2 RECEPTACLES F-2 RECEPTACLES F-3 RECEPTACLES F-3 RECEPTACLES F-4 RECEPTACLES F-4 RECEPTACLES P-2 RECEPTACLES P-2 RECEPTACLES ROOF TYPE TYPE RATING AMP/P 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 RATING AMP/P 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 PA\ 41 _ _ -| PHASE 1 2 3 PHASE 1 2 J RATING AMP/P ''' � 20/1 20/1 20/1 2 20/3 20/1 20/1 20/1 RATING ' TYPE AMP/P ACCESSORIES LIGHTING P-2 LIGHTING P-2 LIGHTING P-2 LIGHTING P-2 EF-2, EF-3, EF-4, EF-5 EWH LEVEL P-2 EWH LEVEL P-1 ACCESSORIES GARAGE DOORS P-2 GARAGE DOORS P-1 SPRINKLER COMPRESSOR EF-1 LEVEL F-4 EF-8 LEVEL F-4 EF-1 ROOF LEVEL EF-7 ROOF LEVEL CKT NO 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CKT NO 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 K�� �� �� ��������� TRANSFORMER INTERNATIONAL GATEWAY CORPORATE PARK � Building � 12201 T%�,� ���"� ^y�vv'�u���w.��uuuuu�ua�vw, Tukwila, WA Q���Q ,v�^�v�wo � SYSTEMS INC. EVERGREEN I " ~~""~-"~~°"~°""-.""^� ,""^� Electrical Contracting and Engneering ROVIS ions No: Item: . Plot Dmta_ Drawn By: Checked By: � Sheet . 3623 E. Marginal Way South Seattle, Washington 98134 Phone: 774-1400 Fax: (206) 774-1401 Arch / 1 ��/1 ��/���� REVISION ` _ Dote: 1 PERMIT SET 12/03/09 Number: 2297 u�^�~^x FqVtmta 04/16/10 �4^1^� �-� /w/ /� ~-r. /u-p0O Drawing Name: 2297-SABEY TRANS RISER.dwg Title . ' ' RISER �~� �~~ � U~`� U �� u�� � � K`�U�~��~~8~� U �0����~n U��U 1 - '- ��������K�� ������ PERMIT SET 1 , � "~ � � ��'—� | J0���U�w��r o� ���'���' SWBD MSB-2 ROOM: P2 GARAGE NORTH SCL TRANSFORMER PAD LOAD DISTRIBUTION FROM: RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 300.0 FUTURE LOADS 400 3 300 361 300.0 FUTURE LOADS 400 3 300 361 AMR 1 20O 3008 FUTURE LOADS 400 3 300 361 VOLTS: 277 3 ' ' 480 3 - ' PHASE 3 3 - ' WIRE 4 3 ' ' BUS: AL 3 - - AJ.C.: 65K 3 ' - M.L.O.: 3 ' ' MAIN CB: YES 3 - - FUSE 3 - ' FLUSH: 3 - ' SURF: YES 3 ' ' ' ' - - K]GND . ' 200% N: - - FD THRU: - ' D8LLUG ' ' TOR ' - B7n« YES - - - ' PANEL T.C.L - ' LOAD (kVA) - - RCPT - _ ' LTG ^ ' - EQP 900 � - ' - HEAT - ' - - - TOTAL 900 ' ' ' - FssDsRTJ:.L. ' - LOAD (kVA) ' - RCPT - .. ' LTG ' - - EQP 90 - ' HEAT - - ' ' - TOTAL 90 ' - ' - FEEDER DWI AND - - kVA 900 - ` TOTAL 900 1.083 AMPS 1,083 ` - 900 '- IN./FG: 8]D CB: N{r[E .FLnnRE � ^ �STALLEDUNoenFUTUREFERM�BY7ENxN� " �� - ��^ ��xv `, — � KO��[2.��1M APR ^"'�u/w ��• " ��^�" ~°°� ~ - �N««t�V�B 04/16;0 pmm�T���v�o��m�nmnu� /" allow ^��nmn�tw��m""m . " block "pmu*/mk"mthe feed n=a�"�u�=m� | / . | | . a �� | | EXISTING SCL 2000 KVA XFMR SCL EXISTING 577LA SPLICE VAULT. CONDUCTORS TO BE ABANDONED NOTE: THE INTENT IS TO HAVE A SEPARATE XFMR FEED EACH SERVICE. EXUSTING SERVICE 2nd FLOOR DATA CENTER SECONDARIES SPLICED IN 712LA VAULT BY SCL V629 (EXISTING) CT l|ST 277/480/3 DIST2 NOT USED MSB REPLACE BREAKERS AS REQUIRED T0 MEET REQUIRED AIC. REMOVE FEED BREAKER AND FEEDER. PANEL TO BE ABANDONED. NOTE: #4 FOOTING GROUND, WATERPIPE & BUILDING STEEL, 2 GRND RODS. #2 RISER FROM SERVICE GROUND THROUGH ELEC. CLOSETS. 1 800/3 SUBMAIN 1 225/3 HP 2 13 ELEV. 2 125/3 AHU-1,4 2 200/3 AHU-2,3 (SPACE ONLY) ( PROV ,u. 1�0D /�vu DIST1 32,000 AIC 0S S T7 ��T1 DIST2 '`�. _-� 277/480/ 117 MCA AHU-4 1 1/4"c. 3#1 200A 200A ] . 1 1 1/4 3�1/0 � '� H1,H2,H3,H4 ( 1 ) 1200 / 3 MDP 3rd FLOOR CT Y�OD ��"" 3_75O,5O0N AL /?\2,w/ 4-4/0 225 MLO HP .GROUND TO REBAR 8c BUILDING STEEL R ''[\|/\ G[l A\/ TOTAL TOTAL 150 MCB LP 117 MCA AHU-1 200 WCB DIST 200A Description 1 ()4"C J- 2 /- MSB-2 INTERGATE WEST BUILDING 'B' 12201 TUKWILA INTL BLVD SEATTLE, WA 2600A BUILDING SERVICE EXISTING DEMAND LOAD (SCL) FUTURE DEMAND FLOOR 3 FUTURE DEMAND FLOOR 1 145 MCA AHU-2 RTU O. 350N CU PROVIDE #2 GRND RISER FROM SWBD THRU EACH ELEC RISER CLOSET. 125A ST 732,600 100,000 797,000 2000A 2nd FLR DATA CENTER SERVICE CURRENT LOAD 513,000 FUTURE DEMAND LOAD 513,000 NOT USED FUTURE 1.00 1.00 1.00 FUTURE (2)2"w/ 4-3/0 cu FUTURE 3#3 ELEV FUTURE LOAD SUMMARY 732,600 100,000 797,000 1.00 513 1.00 513 0 0 0 0 0 0 0 O 0 O O 0 0 0 O 0 0 100% 100% 100% 10096 100% 100% 100% 10096 100% 100% 10096 10096 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% ELEV F-4 P-1 10/18/09 Voltage: 480 Ph: 3 Area/Amps Factor Watts Factor Total Factor TOTAL AMPS 732,600 100,000 797,000 0 0 0 0 0 0 0 0 0 0 513,000 513,000 0 0 0 0 0 0 0 ROOF F-3 REVIEWED Fdli COMPLIANCE WITH NFPA 70 - NEC City of Tukwila BUILDING DIVISION 100% 100% 100% 10096 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%. SCL T MAY 03 20 NEW SCL 2500 KVA XFMR 732,600 100,000 797,000 0 0 0 0 0 0 0 0 0 0 1,629,600 882 120 960 0 0 0 0 0 � 0 0 0 0 0 1,962 513 818 513.000 618 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1,026,000 1,236 CKT NO 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 ` 31 33 35 37 39 . 41 CKT NO 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING ACCESSORIES P-1 P-1 P-1 P-1 F-1 F-2 F-3 F-4 ROOF ACCESSORIES LIGHTING P-2 ELEVATOR RECEPTACLES P-1 FACP F-1 FACP F-2 FACP F-3 FACP F-4 RECEPTACLES F-1 RECEPTACLES F-1 RECEPTACLES F-2 RECEPTACLES F-2 RECEPTACLES F-3 RECEPTACLES F-3 RECEPTACLES F-4 RECEPTACLES F-4 RECEPTACLES P-2 RECEPTACLES P-2 RECEPTACLES ROOF TYPE TYPE RATING AMP/P 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 RATING AMP/P 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 PA\ 41 _ _ -| PHASE 1 2 3 PHASE 1 2 J RATING AMP/P ''' � 20/1 20/1 20/1 2 20/3 20/1 20/1 20/1 RATING ' TYPE AMP/P ACCESSORIES LIGHTING P-2 LIGHTING P-2 LIGHTING P-2 LIGHTING P-2 EF-2, EF-3, EF-4, EF-5 EWH LEVEL P-2 EWH LEVEL P-1 ACCESSORIES GARAGE DOORS P-2 GARAGE DOORS P-1 SPRINKLER COMPRESSOR EF-1 LEVEL F-4 EF-8 LEVEL F-4 EF-1 ROOF LEVEL EF-7 ROOF LEVEL CKT NO 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CKT NO 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 K�� �� �� ��������� TRANSFORMER INTERNATIONAL GATEWAY CORPORATE PARK � Building � 12201 T%�,� ���"� ^y�vv'�u���w.��uuuuu�ua�vw, Tukwila, WA Q���Q ,v�^�v�wo � SYSTEMS INC. EVERGREEN I " ~~""~-"~~°"~°""-.""^� ,""^� Electrical Contracting and Engneering ROVIS ions No: Item: . Plot Dmta_ Drawn By: Checked By: � Sheet . 3623 E. Marginal Way South Seattle, Washington 98134 Phone: 774-1400 Fax: (206) 774-1401 Arch / 1 ��/1 ��/���� REVISION ` _ Dote: 1 PERMIT SET 12/03/09 Number: 2297 u�^�~^x FqVtmta 04/16/10 �4^1^� �-� /w/ /� ~-r. /u-p0O Drawing Name: 2297-SABEY TRANS RISER.dwg Title . ' ' RISER �~� �~~ � U~`� U �� u�� � � K`�U�~��~~8~� U �0����~n U��U 1 - '- ��������K�� ������ PERMIT SET 1 , � "~ � � ��'—� | J0���U�w��r o� ���'���' 1 2 3 4 5 BUILDING 'A' 2 1 00 00000 CABLES BY 44444 i a 1 44 Sii PAD OUNTEI SIMTCHG (2) LOCATIONS PER UTILITY` REQ. REFE3 TO DOML 1 SHEET E0.3, CCJQRD Ate CT LOCA!RON MATT( (T 7') UP NOD SH EFE E5 i STUB PIN S I"••^" .. VAULT`RM,. RE ' SHEET (3) 4" Gr'FTFOM 2N,D E7 TELEPHONE ROOM TO EAST PROP -iJNC FOUND 150ORDIRATE kkTifi'Ft S�14F.ST (TYP) 7 1/2' 5751A VAULT ICG FINISHED GRADE 7121A V629 6 -4'c.? TO 2000A TO UPPER SITE LIGHTING _. {�J 1 "c. STU J MARKER TAPE 12" I MIN. 7 1/2 71/ 1 G EXTEND DUCTBANK 40 PROPERTY UNE, COORDINATE EXACT LOCATION WITH SCL UTILITY FOR CONNECTION TO UTILITY UNDERGROUND MI/4ARY DUCTBANK. (2) 2" &WI SHALL PE.ROU7 D ALONG SIDE -OUe`T BANK'"AT PROPERTY CAPPED -" SEALED FOR FUTURE ACCESS ( l E ‘1TIl i1 U TYTO CORRIDOR FTURE UNDERGROUND FIIdLD1i:D C;1%kDli i D sr sP • 1 L�®®® 36" MIN. 4" MIN. µ TIE WIPE AT 16" ON CENTER DUCT, T1 'Lµ REBAR[ CONTINUOUS TOP & BOTTOM AT EA. CORNER ENVELOPE ON CENTER & AT 2431A)L CONCRETE 300011 MIN, Q RACEVAY N SHOWN) ® = (RACEWAY CONDUIT SHOWN) T � 1 SECTION FACING NORTH No To SCALE MARKER TAPE 12' MIN. T 7 1/2 y FINISHED GRADE 71/2 36' MIN. 4" MIN. ms--•µ TIE WIRE AT 16' ON CENTER DUCT, TYP µ REBAR CONTINUOUS TOP & BOTTOM AT EA. CORNER & AT 24 "MAX. ON CENTER MARK L CONCRETE ENVELOPE 300011 MIN. C!p = 4'R SPARE RACEWAY = 4'R CDUIT WITH UNDUCTDRS (RACEVAY M SHOWN) O ON (RACEVAY K SHOWN) (9 SECTION FACING WEST NOT TO SCALE ,ES TAPE 12 MIN. FINISHED GRADE ' LCONCRETE ENVELOPE 3000* MIN. 36" MIN. 4F. •+ — TE MIRE AT B' ON CENTER DUCT, TYP µ R ®AR CONTINUOUS TOP & BOTTOM AT EA. CORNER & AT 24 "MAX. ON CENTER 4'R SPARE RACEVAY t = 4•R CONDUIT VITH CONDUCTORS (RACEWAY 1) SHOWN) (RACEVAY * SHOWN) TOP SPARE - PRIMARY-- 3 EsT , N1OC To ;'; flM1..E 40 50 TOP FUTURE BUILDING 'B ANDY 'C' CABLES BY SCL SPARE PRIMARY SECTION FACING NORTH t`;-`) MAP 113LE FULDOI,)T NOT TO SCALE TOP - SPARE - PRIMARY MARKER TAPE 7 1/2' J_ RACEVAY M RACEWAY & RA CEEW ) A D Y UI > j S1OWN� NDUC777RS 12" MIN. 7 MARKER TAPE SCALE: 1" = 60' Lc CONCRETE ENVELOPE 3000* MIN. 1 7 1 CONCRETE ENVELOPE 300011 MIN. FINISHED GRADE PARE AT 1Er ON CENTER dUCT, TYP 4 RS TOP & BOTTOM AT EA. CORNER & AT 24 "MAX. ON CENTER 4" MIN. SECTION FACING WEST -, NUi TO SCALE 36' MIN. 4" MIN. z 04 TIE WIRE AT I6" ON CENTER DUCT. TYP CONTINUOUS TOP & BOTTOM AT EA. CORNER & AT 24"MAX. ON CENTER = 4'R SPARE RACEVAY CI - 4'R CDl10UI WITH CONDUCTORS (RACEWAY * SHOWN) (RACEVAY SHOWN) SECTION FACING I1ORTH NOT TO SCALE SITE — POWER PLAN 6 -4'C. 500AL PAD (2) 4'c. PRIMARY ELECTRICAL DETAI 577LA V999 7 -4 - c. TO 2500A 3 -750 MCM AL 1 -500 MCM AL F- L- L_ ,- COLLECTOR BUS / PAD ELECTRICAL DETAIL 1 J (2) 4"c. PRIMARY RE�ONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. \!OT► : Revisions will require a new plan submittal wand may include additional plan review fees. STORM DRAIN LINE WATER L I N E FUEL LINE FIBER OPTICS CONDUIT PROPERTY LINE ROCKERY UNIT MASONRY RETAINING W OVERHEAD POW R LINE UNDERGROUND POWER LINE FILE COPY Permit No. REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC DEC 2 2 2009 /� V VJ N/lf City of Tukwila ILDING DIVISION Plan revie approval is subject to errors and omissions. Approval of construction documents does not authorize the vioiati n of any adopted code or ordinance. Receipt of approv i d py and is acknowledged: By City Of Tukwila BUILDING DIVISION 3 INTERNATIONAL GATEWAY CORP. PARK SABEY TRANSFORMER 12201 Tukwila Intl. Blvd. Seattle, Washington Revisions No: Item: 1 PERMIT SET 12/03/09 Project Number: Plot Date: Drawn By: Checked By: [ Y ERGREEN . C ER SYSTEMS IN Electrical Contracting and Engineering Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Arch. Bckgrnd.: 1 0/1 8/09 12/09/09 - 2:03pm MRP JB Drawing Name: GATEWAY BLDG B.dwg Title : SITE POWER PLAN RIEGF) iFf lD 11 •Mfi I PERMIT SET ELOO73 S. E1.00 Date: E cD c<1 Li E- 0) 0 c\I 0 LI] H- 0 FUTURE ' SH COMPACTOR! • HP/1 EF-2 & EF-3 STACKED i...1 ..... PANEL 'HP' DOOR- OPENER- ; SCALE: 1/8" = - 0" PANEL 'LP DIST DIST CT Ei. EVATOR LOBBY 2 P',.€(•3 .. • LP/29,31 EWH PARKING LEVEL P2 - POWER PLAN STAIRWAY — 31 WP -DOOR. OPENER it LIGHTING CONT OL 'LCG' PANEL ' 31 "–COMM (5)4"C. TO ELEC. ROOM CR DATA J–BOX TO REFEED EXISTING SERVICE P 6 EXISTING 1200A MLO SERVICE 5‘iA \,4 3/4"c. 4 I ; tr n :0 ACCESS CONTROLLS:7 NEW 1200A 277/480 SERVIC ii (10) 4"C ENCASED-1g CONCRETE- ........ - HP/10 EF-4 & EF-5 1 PERMIT SET 12/03/09 STACKED REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION INTERNATIONAL GATEWAY CORP. PARK SABEY TRANSFORMER 12201 Tukwila Intl. Blvd. Seattle, Washington I - EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering Revisions No: Item: Dote: Project Number: Plot Date: Drawn By: M RP Checked By: JB 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774-1400 Fax: (206) 774-1401 Arch. Bckgrnd.: 10/18/09 12/09/09 - 2:03pm Drawing Name: GATEWAY_BLDG B.dwg Title : PARKING LEVEL P2 POWER PLAN RECEIVED DEC ,1 t •2009 PERMIT CENTER ELD9-0793L PERMIT SET E1.P2 E � ro 0 0 � � SCL T / EXISTING SCL 2000 KVA XFMR EXISTING 577LA SPLICE VAULT. NOTE: THE INTENT IS TO HAVE A SEPARATE XBAR FEED EACH SERVICE. EXIISTING SERVICE -\ 2nd FLOOR DATA CENTER 1/- SECONDARIES SPUCED IN 712LA VAULT BY SCL V629 (EXISTING) REMOVE UNUSED � CONDUCTORS CT 0ST �OOO ���� K�7A °."u 277/480/3 NOTE: PROVIDE #4 FOOTING GROUND, 3/0 TO WATERPIPE & BUILDING STEEL, 2 GRND RODS. #2 RISER FROM SERVICE GROUND THROUGH ELEC. CLOSETS. DIST2 RTO 1 1 B00/3 SUBMAIN 1 HP 2 125/3 ELEV. 2 125/3 AHU-1,4 2 200/3 AHU-2,3 /SPACE0■IUA MSB X - AL 277/480/3 200A NF k�R� uvu/ 1�OD /z-vv DIST1 32,000 Al D|ST 277/480 3 117 MCA LAHU-4 1 1/4"c. 3#1 H1,H2,H3,H4 (1 12002/3 MDP 3rd FLOOR CT ��DO ���� MLO 200A 1 1/4"c. 3#1/0 200A 3#6 = GROUND TO REBAR & BUILDING STEEL 117 MCA 200A CLOSET. RISER D | AG R A M 400 H4 145 MCA 400 H3 AHU-2 RTU 75 400 H2 ~J 75 400 H1 /- MSB-2 1/4"c. 3#3 125A ST 225 MCB L4 75 E #2 GRND RISER FROM 225 MCB L3 75 NOT USED 225 MCB L2 ,J FUTURE 225 MCB FUTURE (2)2"w/ 4-3/ cu FUTURE 125A ST FUTURE 3-75 (3)4"C 3-60 1 ROOF F-3 F-2 SCL 500N AL 350N CU P-2 T NEW SCL 2500 KVA XFMR �8 �� � ���'�" ��� �-�~~, ��J ^w�° ^ ' co4b-_ °~6 SCOPE OF WORK: SCL TO INSTALL NEW XFMR REFEED EXISTING 2500A SERVICE PROVIDE (3) 4"C SPARES FOR FUTURE PANEL MIME MIN ENE ns - FUTURELOA[& FTr@��L0AGS : EMI 3�! 72_1 VOLTS: 277 4 So PAN�T,C.L LOA{ RrFT HEAT L7< EOP { �O TOTAL CKT NO 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 NEL 'HP' LIGHTING P-1 ACCESSORIES LIGHTING P-1 LIGHTING P-1 LIGHTING P-1 LIGHTING F-1 LIGHTING F-2 RATING AMP/P 20/1 2O/1 LIGHTING F-3 LIGHTING F-4 LIGHTING ROOF TYPE -0 0 -0 0 - 0 0 -0 0 -0 0 -0 0 - 0 0 - 0 0 - 0 0 - 0 0 - 0 0 -0 0 -0 0 -0 0 -0 0 -0 0 -0 0 PHASE 1 2 3 RATING lypE AMP/P 20/1 20/1 20/1 20/1 20/3 20/1 20/1 ACCESSORIES LIGHTING P-2 LIGHTING P-2 LIGHTING P-2 LIGHTING P-2 EF-2, EF-3, EF-4, EF-5 EWH LEVEL P-2 EWH LEVEL P-1 CKT NO 2 4 6 8 10 12 14 18 18 20 22 24 26 28 30 32 34 36 38 40 42 [� |�A / /` CKT NO 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 , , \ [-| | �l � F ' | | �~ , `_�_ �_/ ACCESSORIES UGHTING P-2 ELEVATOR RECEPTACLES P-1 FACP F-1 FACP F-2 FACP F-3 FACP F-4 RECEPTACLES F-1 RECEPTACLES F-1 RECEPTACLES F-2 RECEPTACLES F-2 RECEPTACLES F-3 RECEPTACLES F-3 RECEPTACLES F-4 RECEPTACLES F-4 RECEPTACLES P-2 RECEPTACLES P-2 RECEPTACLES ROOF TYPE RATING AMP/P 20/1 20/1 o»/1 n»/1 - 0 0 - 0 0 - 0 0 -0 0 - 0 0 -0 0 -0 0 -0 0 -0 0 -0 0 - 0 -0 0 -0 0 - 0 0 - 0 0 PHASE 2 3 RATING AMP/P 20/1 ACCESSORIES GARAGE DOORS P-2 GARAGE DOORS P-1 SPRINKLER COMPRESSOR EF-1 LEVEL F-4 EF-8 LEVEL F-4 EF-1 ROOF LEVEL EF-7 ROOF LEVEL CKT NO 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 ' ��/���/�_��� L(ADD@ii.:1Burn0N tG E.0 • ------- oi --- |---' /"" ' C@� FUTURE .( � SWBD P2 GARAGE NORTH TRANSFORMtRPAD '|--- ~-----'--`----`--------'---`----`' - . �]TE FI.iTURE LE[ ;NDER F1„.17��EFE.RNI TE�LA,N7 ects m � K�Sc�^2 � 1200 1 4 AL 1 YES FUSE YES kVA 1 L TOTAL • FEEDER T.C, LTA A) � REVIEWED FOR _COMPLIANCE Wxoox � NFPA70~NEC � DEC 2 2 200 1 City of Tukwila ! BUILDING DIVISION ` FEEDER DEMAND CORP. INTERNATIONAL GATEWAY PARK SABEY TRANSFORMER 12201 �.~+7 ���u� Tukwila Intl. Blvd. Seattle, Washington . � Revisions No: Item: Project Number: Plot Date: Drawn By: Checked By: 0 .1 I � SYSTEMS U��~ I ^ ~°""~."~ ~� v v� n �~^mv� ..~^�. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: 774-1400 Fax: (206) 774-1401 Date: PERMIT SET 12/03/09 Arch. Baornd/ � 1��/���/���� /^m ^��^�w 12/09/09 �.�� xu�/�~�� - 2:03pm ������ un ^� U�� ��� Drawing Name: GATEWAY_BLDG B.dwg Title . RISER ���~�K~� ���U �� � � ��� U�-���^ 8~� U �U��k� ~� U��U RECEW DEc 1 1, nog pew GEM ��������U�_ ������ U PERMIT SET U V E5.00 - LOAD SUMMARY _ __- _-_ �- � 1O/18/O8 | o ^ / _ _____ |NTERG/\TEVVEGTBU|LD|N(� "B" 12201 TUKVV|LA |NTLBLVC) � SEATTLE WA L .. ,_-__--____-'_-_-___-__- ---------------------------'------------------------ ` tFactorTctalWatts -- ''— ` Voltage: Factor/ T�TAL AMPS " ------------' ��� --�� - '---' 1.00 1.00 1.00 ----'� -- � - -- -- � . ___' ����������_ T32 8OO 100% OO2 --���, 120 787 100Y6' 787.000 960 3500A BUILDING SERVICE 73�0OO /���- 100000 797,000 LOA EXISTING DEMAND - FUTURE DEMAND FLOOR 3 FUTURE DEMAND FLOOR 1 732000 1OO.00O ��� 10 1DOY6 100961 797.000 0 10096 0 100961 0 0 0 100Y6 O` 10096 1OO9 _ 10096 O| O � � � O � O D O 0 100% 0 _+ O 0 1OO96 J O 100% O--1OO96) D - » ------------------------------------------------------- O 10096 -- - 100% 0 -- 0 10096 0 -- O � 0 | 0 0 0 - -- 100% 100V 0 100% 0 0 100 0 96 100% 0 0 0 100%/ 0 100% | 0 0 TOTA- �� 962 2000A 2nd FLR DATA CENTER SERVICE CURRENT LOAD 513.000 1.00 513 1OO96� | 513 | 10096 513 618 FUTURE DEMAND LOAD ------------------------------U-----------------------------'---'--------------------------------------' 513,000 ' 1.00 _-_�_-_ 513,000 _-___�� '�/�__ 0 O 100%1 100% 10096 513,000 OOO � O O 100% 618 -______ 1OO96 O 0 10096 i O O 0 100% O 1OO96 l 0 0 0 10096 0 10096! 0 0 0 { 100% . 0 100%1 O �� 1OO.. . O � | 1OOY�. 0 0 1=11 O ' ------ ��___ " | O 0 _ | 0 TOTAL i 1 1,026,000 1,236 E � ro 0 0 � � SCL T / EXISTING SCL 2000 KVA XFMR EXISTING 577LA SPLICE VAULT. NOTE: THE INTENT IS TO HAVE A SEPARATE XBAR FEED EACH SERVICE. EXIISTING SERVICE -\ 2nd FLOOR DATA CENTER 1/- SECONDARIES SPUCED IN 712LA VAULT BY SCL V629 (EXISTING) REMOVE UNUSED � CONDUCTORS CT 0ST �OOO ���� K�7A °."u 277/480/3 NOTE: PROVIDE #4 FOOTING GROUND, 3/0 TO WATERPIPE & BUILDING STEEL, 2 GRND RODS. #2 RISER FROM SERVICE GROUND THROUGH ELEC. CLOSETS. DIST2 RTO 1 1 B00/3 SUBMAIN 1 HP 2 125/3 ELEV. 2 125/3 AHU-1,4 2 200/3 AHU-2,3 /SPACE0■IUA MSB X - AL 277/480/3 200A NF k�R� uvu/ 1�OD /z-vv DIST1 32,000 Al D|ST 277/480 3 117 MCA LAHU-4 1 1/4"c. 3#1 H1,H2,H3,H4 (1 12002/3 MDP 3rd FLOOR CT ��DO ���� MLO 200A 1 1/4"c. 3#1/0 200A 3#6 = GROUND TO REBAR & BUILDING STEEL 117 MCA 200A CLOSET. RISER D | AG R A M 400 H4 145 MCA 400 H3 AHU-2 RTU 75 400 H2 ~J 75 400 H1 /- MSB-2 1/4"c. 3#3 125A ST 225 MCB L4 75 E #2 GRND RISER FROM 225 MCB L3 75 NOT USED 225 MCB L2 ,J FUTURE 225 MCB FUTURE (2)2"w/ 4-3/ cu FUTURE 125A ST FUTURE 3-75 (3)4"C 3-60 1 ROOF F-3 F-2 SCL 500N AL 350N CU P-2 T NEW SCL 2500 KVA XFMR �8 �� � ���'�" ��� �-�~~, ��J ^w�° ^ ' co4b-_ °~6 SCOPE OF WORK: SCL TO INSTALL NEW XFMR REFEED EXISTING 2500A SERVICE PROVIDE (3) 4"C SPARES FOR FUTURE PANEL MIME MIN ENE ns - FUTURELOA[& FTr@��L0AGS : EMI 3�! 72_1 VOLTS: 277 4 So PAN�T,C.L LOA{ RrFT HEAT L7< EOP { �O TOTAL CKT NO 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 NEL 'HP' LIGHTING P-1 ACCESSORIES LIGHTING P-1 LIGHTING P-1 LIGHTING P-1 LIGHTING F-1 LIGHTING F-2 RATING AMP/P 20/1 2O/1 LIGHTING F-3 LIGHTING F-4 LIGHTING ROOF TYPE -0 0 -0 0 - 0 0 -0 0 -0 0 -0 0 - 0 0 - 0 0 - 0 0 - 0 0 - 0 0 -0 0 -0 0 -0 0 -0 0 -0 0 -0 0 PHASE 1 2 3 RATING lypE AMP/P 20/1 20/1 20/1 20/1 20/3 20/1 20/1 ACCESSORIES LIGHTING P-2 LIGHTING P-2 LIGHTING P-2 LIGHTING P-2 EF-2, EF-3, EF-4, EF-5 EWH LEVEL P-2 EWH LEVEL P-1 CKT NO 2 4 6 8 10 12 14 18 18 20 22 24 26 28 30 32 34 36 38 40 42 [� |�A / /` CKT NO 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 , , \ [-| | �l � F ' | | �~ , `_�_ �_/ ACCESSORIES UGHTING P-2 ELEVATOR RECEPTACLES P-1 FACP F-1 FACP F-2 FACP F-3 FACP F-4 RECEPTACLES F-1 RECEPTACLES F-1 RECEPTACLES F-2 RECEPTACLES F-2 RECEPTACLES F-3 RECEPTACLES F-3 RECEPTACLES F-4 RECEPTACLES F-4 RECEPTACLES P-2 RECEPTACLES P-2 RECEPTACLES ROOF TYPE RATING AMP/P 20/1 20/1 o»/1 n»/1 - 0 0 - 0 0 - 0 0 -0 0 - 0 0 -0 0 -0 0 -0 0 -0 0 -0 0 - 0 -0 0 -0 0 - 0 0 - 0 0 PHASE 2 3 RATING AMP/P 20/1 ACCESSORIES GARAGE DOORS P-2 GARAGE DOORS P-1 SPRINKLER COMPRESSOR EF-1 LEVEL F-4 EF-8 LEVEL F-4 EF-1 ROOF LEVEL EF-7 ROOF LEVEL CKT NO 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 ' ��/���/�_��� L(ADD@ii.:1Burn0N tG E.0 • ------- oi --- |---' /"" ' C@� FUTURE .( � SWBD P2 GARAGE NORTH TRANSFORMtRPAD '|--- ~-----'--`----`--------'---`----`' - . �]TE FI.iTURE LE[ ;NDER F1„.17��EFE.RNI TE�LA,N7 ects m � K�Sc�^2 � 1200 1 4 AL 1 YES FUSE YES kVA 1 L TOTAL • FEEDER T.C, LTA A) � REVIEWED FOR _COMPLIANCE Wxoox � NFPA70~NEC � DEC 2 2 200 1 City of Tukwila ! BUILDING DIVISION ` FEEDER DEMAND CORP. INTERNATIONAL GATEWAY PARK SABEY TRANSFORMER 12201 �.~+7 ���u� Tukwila Intl. Blvd. Seattle, Washington . � Revisions No: Item: Project Number: Plot Date: Drawn By: Checked By: 0 .1 I � SYSTEMS U��~ I ^ ~°""~."~ ~� v v� n �~^mv� ..~^�. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: 774-1400 Fax: (206) 774-1401 Date: PERMIT SET 12/03/09 Arch. Baornd/ � 1��/���/���� /^m ^��^�w 12/09/09 �.�� xu�/�~�� - 2:03pm ������ un ^� U�� ��� Drawing Name: GATEWAY_BLDG B.dwg Title . RISER ���~�K~� ���U �� � � ��� U�-���^ 8~� U �U��k� ~� U��U RECEW DEc 1 1, nog pew GEM ��������U�_ ������ U PERMIT SET U V E5.00