Loading...
HomeMy WebLinkAboutPermit EL09-0794 - CARTERS RETAILCARTERS RETAIL 17250 SOUTHCENTER PY SUITE 144 ELO9-0794 City .f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http://www.citukwila.waus Parcel No.: 7888920020 Address: 17250 SOUTHCENTER PY TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL09 -0794 Issue Date: 12/31/2009 Permit Expires On: 06/29/2010 Tenant: Name: CARTERS RETAIL Address: 17250 SOUTHCENTER PY, STE 144 , TUKWILA WA Owner: Name: WIG PROPERTIES LLC -SS Phone: Address: 4811 134TH PL SE , BELLEVUE WA Contact Person: Name: CLAUDINE SIEDLER Phone: 425 641 -2044 Address: 4811 134 PL SE , BELLEVUE WA Contractor: Name: NORTH PACIFIC ELECTRIC INC Phone: 360- 943 -6020 Address: 5746 BOSTON HARBOR RD , OLYMPIA WA Contractor License No: NORTHPE957JA Expiration Date: 04/01/2011 DESCRIPTION OF WORK: ELECTRICAL FOR TI INCLUDING THERMOSTAT WIRING Value of Electrical: NRES: $30,000.00 RES: $0.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $725.00 National Electrical Code Edition: 2008 Date: 0-'3 —0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this per does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo r ance of v y 6 z > k . 1 ary authorized to sign and obtain this electrical permit. Signature: Print Name: Date: 3( ,Ro This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL09 -0794 Printed: 12 -31 -2009 Parcel No.: 7888920020 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17250 SOUTHCENTER PY TUKW CARTERS RETAIL PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL09 -0794 ISSUED 12/11/2009 12/31/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating constructiop or the performance of work. Signature: Print Name: Use / + i et_D Date: 3( fee- °Zoo, doc: Cond -Elec EL09 -0794 Printed: 12 -31 -2009 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htt ://www.ci.tukwita.wa.us Electrical Permit No. i0'\ —O TIt Project No. For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 788892- 0020 -07 Site Address: 17250 Sputhcenter Pkwy, Tukwila, WA 98188 Suite Number: 144 Floor: 1 Tenant Name: Carter's Retail Inc. Property Owners Name: Wig Properties LLC - SS Mailing Address: 4811 134th Place SE New Tenant: ❑ Yes ❑ .. No Bellevue WA 98006 City State Zip CONTACT PERSON Who do we contact when your permit is ready to be issued Name: Claudine Siedler Mailing Address: E -Mail Address: 4811 134th Place SE Day Telephone: (425) 641 -2044 Bellevue WA 98006 csiedler @wigproperties.com City Fax Number: State (425) 865 -8648 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: TBD City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $_540)C00 Scope of Work (please provide detailed information): W to Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant improvement ❑ Low Voltage 0 Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: gj Puget Sound Energy ❑ Seattle City Light Hc\ApplicationsTorms- Applications On Line \l -2009 - Electrical Permit ApplicationAoc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $145.60 (including an attached garage) ❑ Garages, pools, spas and outbuildings $78.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added /altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $57.00 (alarm, fumace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: Print Name: Manmohan K. Wig Day Telephone: (425) 747 -8540 Mailing Address: 4811 134th Place SE Bellevue WA 98006 City Date Application Accepted: Date Application Expires: H:AApplicalions \Forms - Applications On Line AI -2009 - Electrical Permit Application.doe bh State Zip Staff Initials: i Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 7888920020 Address: 17250 SOUTHCENTER PY TUKW Suite No: Applicant: CARTERS RETAIL RECEIPT Permit Number: EL09 -0794 Status: APPROVED Applied Date: 12/11/2009 Issue Date: Receipt No.: R09 -02057 Payment Amount: $580.00 Initials: WER Payment Date: 12/29/2009 10:54 AM User ID: 1655 Balance: $0.00 Payee: WIG PROPERTIES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3785 580.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 580.00 Total: $580.00 PAYMENT RECEIVED doc: Receipt -06 Printed: 12 -29 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 7888920020 Permit Number: EL09 -0794 Address: 17250 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 12/11/2009 Applicant: CARTER'S RETAIL Issue Date: Receipt No.: R09 -01985 Initials: User ID: Payee: JEM 1165 Payment Amount: $145.00 Payment Date: 12/11/2009 12:58 PM Balance: $580.00 WIG PROPERTIES LLC -SS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3773 145.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 145.00 Total: $145.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 12 -11 -2009 INSPECTION NO. INSPECTION RECORD Retain a copy with permit E °r/PE MIT N CITY OF TUKWILA BUILDING DIVISION 'a` 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project:_, (:(0...41 Type of Inspection: Oa Address: Date Called: Special Instructions: Date Wanted: 0'� a.m. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. OM M ENTS: Cigkdon045 tot / i� (4 � 02/0\e/1 Date: 0 �,l 1 �rji,1VA1 ri $60.00 REINSPECTION FEE RE LURED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit (Of o77 T NO. 2-- (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: emo.• keriki� Type of Inspection: ; f RECtP sor Address: Date Called: Special Instructions: Date Wanted: �j aim. C. Requester: Phone No: ElApproved per applicable codes. 53 Corrections required prior to approval. COMMENTS: — kw o4C POE( 4-ad w4ioit l- - gia-Aik-pslicocwi 41TI foof1bf L r& - la 5/uc. r 5E4L o o'4 RAF RECtP sor - Be-elvta1R NJIOrt && W/' kf &b/w rd. roe_ V4C P 5d out - 'J'i'e &a 5 i,J 44€L_ to CK Tzs oCC.07 r ric, frio4 og l o Inspector: jr 6/ Date: 02,1011/0 $60.00 REINSISECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPEt TION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit P MIT NO. Project: eiw.r. 15 Witif L Type of Inspection: 703 Address: fl l Sc, .5.c.. .5.c.. P Date Called: Special Instructions: Date Wanted: 7/°1-. a.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: COLrniti Cosiec 401/61 14 psi Co+jPuer6 Inspector: Date: ol/02. -l10 D $60.00 REINSPECTION FEE REO IRED. Prior to inspection, feel must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6� -01fl PE IT NO. CITY OF TUKWILA BUILDING DIVISION AZ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: I I 5 KCTAIL/ ��_{w Type of Inspection: 7„,„ V Address. /77-So45.c*Pi. Date Called: Special Instructions: Date Wanted: 2; i /7 m: Requester: Phone No: f Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: af-wec‘ ri $60.00 REINSP CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 01/27 to Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6o-o71 E r MIT N . • (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: } _ ii"" " Type of Inspection: 7003 Addre . 72o -5.C-- Date Called: Special Instructions: Date Wanted: / / Cu p.m. Requester: Phone No: DApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Date: 0' ' o ri $60.00 REINS CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: • r INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PE MIT NO. h (206)431 -3670 Proje rots kerm I.- Type of Inspection: Address: 172.5o5 .e.p, Date Called: Special Instructions: Date Wanted: a glen. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. , OMMENTS: 0. K - Inspector: Date: of of r r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: - A.._ .1 ..,. _ _- _ ........ _ ....:'7�...ca,.�w. tA! Merchandise Display Allowance Total Allowance Space Type: Retail Space Area (sf): 4000 sf isp Space Type: aY Area (sf)M =' FILE COPY Space Calculation Description Lamp Mark Fixture Wattage Fixture Quantity Total 4 Fl O 4 W T A 08 �4 � rescen t w i i rg, (2) W T- ABM 108 4 Fl uor Oa t `153Q =Lighthig:Pawer HA) lowaflce Qptioi 2006 Washinton State Energy Code Compliance Form Allowed Wattage per Table 15 -1: 1.5 W /sf Space Allowed Wattage: 6000 W Total = Allowance Wattage per Table 15 -1 footnote 10: Mtr'chanilsi? Pisplay ?tlipwance Wattage: 1.5 7874 W Space Allowed Wattage: chandlse:Display Allowance Wattage: Total Allowance: 6000 W 968 W W REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION CITY OF n VED DEC 11 2009 PERMIT CENTER 1 — 01 cH 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Southcenter Square Date 12/16/2009 17250 Southcenter Parkway, Space 144 (Carters) For Building Department Use Tukwila, WA 98188 Applicant Name: carters ApplicantAddress: Southcenter Square, space 144 Applicant Phone: unknown FILE COPY ELO'J' cfAl REVIEWED P COMPLIANCE WITH NFPA 70 - NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION RECEIVED DEC 112009 PERMIT CENTEF 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Project Info Project Address Southcenter Square Date Revised July 2007 12/16/2009 17250 Southcenter Parkway, Space 144 (Carters) Tukwila, WA 98188 Applicant Name: Carters Applicant AddreSS: Southcenter Square, space 144 Applicant Phone: unknown For Building Department Use Project Description Compliance Option [11 New Building ❑ Addition Q Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 "" Area in ft2 Allowed x Area Sales retail sales 1.50 4000.0 6000.0 Sales display allowance 1.50 1312.0 1968.0 Sales Al - 2 x 4 Fluorescent 3 64.0 192.0 -1 (over) - document all exceptions on form LTG- Proposed Lighting Wattage Total Allowed Watts 7968.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales A - 2 x 4 Fluorescent 44 108.0 4752.0 Sales A /EM - 2 x 4 Fluorescent with emergency 6 108.0 648.0 Sales Al - 2 x 4 Fluorescent 3 64.0 192.0 Sales Al - 2 x 4 Fluorescent with emergency 1 64.0 64.0 Sales B - Semi Recessed Metal Halide Wall Washer 21 70.0 1470.0 Sales 81 - Track mounted Metal Halide Wall Washer 4 75.0 300.0 Sales F - 4 foot strip fluorescent 7 64.0 448.0 o l Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 7874.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist answer If is occupancy ked type is "Other" and fixture answer is checked, the number of fixtures in in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section ( 1521) ❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. -"1 Unit LIgntin g rower Allowance Use' LPA2 (W /sfLUse' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)'.' 11 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments', restaurants /bars° 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia °, assembly spaces° 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet/conference /exhibition hall'" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies° (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Southcenter Square Date 12/16/2009 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the Use listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2 ** Ceiling Height for this room Ceiling Height limit for this exception ** Adjusted LPA Watts per ft2 Sales retail sales - display credit 1.50 10.0 feet 12 feet 1.50 ** From Table 15 -1 based on exceptions listed in footnotes 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address southcenter square 'Date 12/16/2009 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch yes 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n . a . (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n . a . 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts Indicate watts for each exit sign I 1 LIGHTING POWER ALLOWANCE (Section 1530- 1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) 1 no I 1511 Elec motor efficiency jMECH -MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) n.a. I 1540 (Transformers 'Indicate size and efficiency 1 If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Ener Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas Tess than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry -type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). 3ERIWIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL09 -0794 PROJECT NAME: CARTER'S RETAIL INC. DATE: 12 -11 -09 SITE ADDRESS: 17250 SOUTHCENTER PY, STE 144 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: �uiTding Division �■,`v� Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 12-15-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: DUE DATE: 01-12-10 Approved with Conditions tifr Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page Page 1 of 2 Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company NORTH PACIFIC ELECTRIC INC 3609436020 5746 BOSTON HARBOR RD OLYMPIA WA 98506 THURSTON Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602117535 ACTIVE NORTHPE957JA ELECTRICAL CONTRACTOR 4/1/2005 4/1/2011 GENERAL UNUSED Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status NORTHPE159RU NORTH PACIFIC ELECTRIC INC ELECTRICAL CONTRACTOR GENERAL UNUSED 12/31/1985 3/31/2001 ARCHIVED NORTHPE277B3 NORTH PACIFIC ELECTRICAL INC ELECTRICAL CONTRACTOR GENERAL UNUSED 1/23/1973 12/31/1986ARCHIVED NORTHPE994JB NORTH PACIFIC ELECTRIC ELECTRICAL CONTRACTOR GENERAL UNUSED 4/3/2001 4/3/2005 EXPIRED MASTER ELECTRICIAN INFORMATION License KULLMBM974BU Name KULLMANN, BERNHARD https://fortress.wa.gov/Ini/bbip/Detail.aspx 12/31/2009 1-1 S O SIBH I SCHEDULE NOTES: a:) THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE FOR ACCURACY PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO TENANT CONSTRUCTION PROJECT MANAGER. DESCRIPTION G.G. GARTERS LANDLORD DESCRIPTION G.G. GARTERS LANDLORD N/A DIVISION 01000 - GENERAL SUPPLY INSTALL SUPPLY INSTALL AS-IS BY LL REMARKS SUPPLY INSTALL SUPPLY INSTALL BY LL REMARKS LANDLORD BUILDING PERMIT SUBMITTAL • DIVISION 15000 - MECHANICAL LANDLORD BUILDING PLAN GHEGK FEES • HVAG EQUIPMENT "ROOF TOP" • LANDLORD BUILDING PERMIT FEES • • • ROOF WORK AND EQUIPMENT CURBS 0 000 TENANT BUILDING PERMIT SUBMITTAL BY TENANTS PERMIT VENDOR HVAG DISTRIBUTION, DUCTWORK TENANT BUILDING PLAN CHECK FEES G.G. SHALL PICK UP PERMIT AND PERMIT FEES DIFFUSERS TENANT BUILDING PERMIT FEES 0 BUILDING PERMIT FEES EXHAUST FANS AND VENTING DEMOLITION N/A STOCKROOM UNIT HEATER • LANDLORD GLEAN -UP #I AT TURN -OVER 0 SMOKE DETECTORS • TENANT G.G. FINAL GLEAN -UP #I AT TURN -OVER 0 0 FIRE SPRINKLER MAIN 0 EXISTING TENANT G.G. FINAL GLEAN -UP #2 AT PRE- OPENING 0 COORDINATE WITH STORE MANAGER SPRINKLER SYSTEM 0 EXISTING NEUTRAL PIERS AND MALL BULKHEAD EXISTING SPRINKLER SYSTEM MODIFICATIONS • OTHER PERMITS, FEES, INSURANCE 0 0 PLUMBING FIXTURES (TOILET ROOMS) TEMPORARY POWER • 0 IF REQUIRED DRINKING FOUNTAIN N/A TEMPORARY BARRICADES • 0 FOR STOREFRONT WORK WATER AND SEWER STUB • TEMPORARY BARRICADE GRAPHICS • SANITARY PIPING TRASH REMOVAL/DISPOSAL AND DUMPSTERS 0 0 DOMESTIC WATER PIPING • DUMPSTER AT TURNOVER • • G.G. TO EMPTY, DUMPSTER PRIOR TO MERCHANDISE ARRIVAL ACCESS PANELS • FINAL INSPECTIONS AND CERTIFICATE OF OGGUPANGY • COORDINATED WITH TENANTS ARCH IGTEGT WATER HEATER MOP SINK, MOP HANGER AND HOSE DIVISION 1 6000 - ELECTRICAL DIVISION 03000 - CONCRETE WORK ELECTRICAL SERVICE CONDUIT TO TENANT SPACE • NEW SERVICE SEE ELECTRICAL DRAWINGS. CONCRETE TRENCH FOR NEW PLUMBING • • ELECTRICAL SERVICE NEW SERVICE SEE ELECTRICAL DRAWINGS. CONCRETE TRENCH FOR GASHDESK POWER 0 • ELECTRICAL PANELS 0 NEW BY LANDLORD CONCRETE POUR BACK FOR LEAVE OUT • • TRANSFORMER • NEW BY LANDLORD FIRE ALARM SYSTEM DIVISION 05000 - METALS EMERGENCY LIGHTING 0 SEE LIGHT FIXTURE SCHEDULE DEMISING PARTITION FRAMING • • EXIT SIGNS 0 SEE LIGHT FIXTURE SCHEDULE, RETAIL AREA TO BE CLG MOUNTED DEMISING PARTITION FURRING N/A FLUORESCENT LIGHT FIXTURES • SEE LIGHT FIXTURE SCHEDULE TOILET ROOM WALL FRAMING 0 FLUORESCENT LAMPS 0 SEE LIGHT FIXTURE SCHEDULE STOCKROOM WALL FRAMING • ACCENT LIGHT FIXTURES 0 0 SEE LIGHT FIXTURE SCHEDULE OFFICE WALL FRAMING 0 ACCENT LIGHT LAMPS 0 SEE LIGHT FIXTURE SCHEDULE COLUMN ENCLOSURE FRAMING • THERMOSTATS 0 TENANT SPEC, LIGHTSTAT MODEL THE -POI MASONRY WALL METAL FURRING 0 EXISTING WIRING, CIRCUITING, RECEPTACLES, SWITCHES 0 ALL LANDLORD ITEMS SEE E -I AND E -2 WIRING, CIRCUITING, RECEPTACLES, SWITCHES • 0 ALL TENANT ITEMS SEE E -I AND E -2 WIRING AND CONNECTION OF GASHWRAP 0 0 SEE ELECTRICAL DRAWING E -2 DIVISION 06000 - WOOD AND PLASTICS TIME CLOCK, FOR STOREFRONT SIGN ROUGH CARPENTRY, TENANT WORK, 0 0 ALL LOW VOLTAGE TELEPHONE AND DATA GAT -5 WIRING • • G.G. TO CONTRACT WITH COMM WORKS FOR INSTALL INTERIOR WOOD TRIM, TENANT WORK SHOPPER TRACK (J -BOX 4 CONDUIT) • BLOCKING (FIRE RETARDANT LUMBER 4 PLYWD) 0 • SHOPPER TRACK (CABLE) 0 0 G.G. TO CONTRACT WITH GOMM WORKS FOR INSTALL TELEPHONE CONDUIT AND PULL STRING WIRING 0 EXISTING, G.G. TO RELOCATE IF REQUIRED TELEPHONE SERVICE 0 0 G.G. TO COORDINATE WITH TENANT FOR PHONE SERVICE TENANT VENDORS: DIVISION 07000 - THERMAL 4 MOISTURE PROTECTION FIBERGLASS BATT INSULATION 0 0 LIGHTING SPECIALTY STORE LIGHTING 35 INDUSTRIAL PARK RD. CENTERBROOK, GT Larry De Francesco (860) 161- 0110x204 y FIXTURES LEIDEN CABINET COMPANY 2385 EDISON BOULEVARD TWINSBURG, OH 44081 Mike Hopp (330) 425 -8555 LOCKS / A -OK SECURITY DOOR HOW. (817) 265 -2100 Garlgoa- oksecurity AIR INFILTRATION BARRIER • EXISTING SEALANT AND CAULKING 0 0 0 GENERAL WHERE REQUIRED BY NEW WORK FIRE STOPPING 0 0 WHERE ANY NEW REQUIRED ROOFING/FLASHING WATERPROOF MEMBRANE "WET AREAS" N/A FLOORING SG5 FLOORING SYSTEM 530 S. MAIN ST. SUITE 110 ORANGE, GA 12868 BARRY SCHWARTZ (714)) -2146 SIGNS IMAGE CONSULTING SERVICES 1 175 Donwell 5. Euclid, OH 44121. Patrick O'Dea (440) 15I-11 1/ LOW VOLTAGE GOMM - WORKS, LLG CONTRACTOR 3550 ANNAPOLIS LAND N. PLYMOUTH, MN 55447 Tel. 136 -852 -3100 DIVISION 08000 — DOORS 4 WINDOWS STOREFRONT ENTRY DOORS • STOREFRONT ALUMINUM FRAMING AND GLASS • INTERIOR DOORS, FRAMES, • SEE DOOR SCHEDULE, r 542 PROJECT DATA / DIRECTORY: INTERIOR DOOR LEVER SETS 0 0 0 SEE DOOR SCHEDULE, PROJECT NAME: CARTERS, SPACE NO. 144 SQUARE PKWY WA 18188 CLOTHING STORE APPAREL SIEDLER LLG PLAGE SE WA 18006 RETAIL DRIVE LAG, WI 54135 Schainske Manager 332 -0420 PROJECT COORDINATOR: DON KAMM T REAR SERVICE DOOR, FRAME 4 HARDWARE • SEE DOOR SCHEDULE, REAR SERVICE DOOR EXIT DEVICE SYSTEM 0 0 SEE DOOR SCHEDULE, " °» AOUTHCENTER 17250 SOUTHCENTER TUKWILA, PROJECT DESCRIPTION: CHILDRENS GADD TECH 225 Oakland Rd., Suite 105 South Windsor, GT 06074 Tel. (860) 783 -5670 TENANTS ARCHITECT: KENNETH L. BUTTS, ARCHITECT A -OK SECURITY LOCKS AND GORES o SEE DOOR SCHEDULE DIVISION 01000 - FINISHES AND RELATED TENANT COORDINATOR: CLAUDINE CEILING SUSPENSION SYSTEMS • 124 STAGE COACH ROAD BELL CANYON, GA 11307 TEL: (818) 111 -4272 FAX: (818) -111 -4321 TENANTS ENGINEER: DONN PENN, CONSULTING ENGINEER ACOUSTICAL TILES (SALES) 0 WIG PROPERTIES 4811 -134TH BELLEVUE, TENANT: CARTERS ACOUSTICAL TILES (NON - SALES) • GYP. BD. CEILING (SALES) N/A GYPSUM WALL BOARD (DEMISING PARTITION) 0 0 BUILDING DEPT.: 655 WESTPORT PARKWAY, SUITE 500 GRAPEVINE, TEXAS 76051 Tel. 817 -410 -2858 DEPARTMENT OF COMMUNITY DEVELOPMEN 6300 SOUTHCENTER GLVD, #100 TUKWILA, WA 18188 ATT: BUILDING OFFICIAL (206) 431 -3655 GYPSUM WALL BOARD (HG TOILET ROOM PARTITIONS) • GYPSUM WALL BOARD (STOCK ROOM PARTITION) ® GYPSUM WALL BOARD (COLUMN ENCLOSURES) 0 W5167 KENNEDY FOND DU Ms. Brenda Project TEL: (120) GYPSUM WALL BOARD (OFFICE /HALL) 0 GYPSUM WALL BOARD (MOP SINK AREA) SALES AREA FLOORING 0 • SHEET VINYL FLOORING (TOILET ROOM) • VGT (OFFICE /STOCK /HALL) • WALL BASE (SALES) 0 0 CODE SUMMARY VINYL BASE (OFFICE /STOCK /HALL) ® REDUCER STRIPS, ADHESIVE, ETC. APPLICABLE CODES: BUILDING CODE: 2006 International Building Code - Chapter 51 -50 WAG M ECHANICAL CODE: 2 006 I nternational Mechanical Code (IMG 06) -Gha p CODE: 2006` Uniform Plumbing Code (Chapters 51 -56 and 51 ELECTRICAL CODE: 2008 National Electrical Code (NFPA 10) ENERGY CODE: 2006 Washington State Energy Code- Chapter 51 -11 ACCESSIBILITY: 2005 IGG /ANSI A111.1 CHAPTER 10 MEANS OF EGRESS OCCUPANCY CALCULATIONS: TABLE 1004.1.1 ROOM OCCUPANT OCCUPANT 2 EXITS ROOM DESCRIPTION AREA FACTOR LOAD REQUIRED BUILDING DATA: ter 51 -52 WA USE GROUP: (M) Mercanti -57 WAG) CONSTRUCTION TYPE: I IB GROSS FLOOR AREA: 4,000 S.F. WAG OCCUPANCY LOAD: 112 SPRINKLER: Yes NFPA IE FIRE ALARM: Yes NFPA 1 FIRE EXTINGUISHERS: Yes NFPA IC MINIMUM PLUMBING FIXTURES (EXISTING) 2006 UNIFORM PLUMBING CODE, CHAPTER 4 412.5. Facilities in Mercantile and Business Occupancies Se TABLE "A" OCCUPANT LOAD FACTOR GROUP "M" 200 / 4000 S.F. = 20 PERSONS 10 MALE / 10 FEMALE TABLE 4 -I RETAIL OR WHOLESALE STORES WATER CLOSET: MALE I:1 -100 PROVIDED I FEMALE I:I -25 PROVIDED I LAVATORY: ONE FOR EVERY TWO WATER CLOSETS PROVIDED MALE I PROVIDED FEMALE : I DRINKING FOUNTAINS: 0:1 -30 NOT REQUIRED SERVICE SINK: NOT REQUIRED PROVIDED: FLOOR PREP, INCLUDING LEVELING • • ® FLOOR PROTECTION 0 • • PAINTING, FINISHING SALES AREA • PAINTING, FINISHING NON -SALES AREA 0 CORNER GUARDS 0 SEE SHEET AI.2 FOR SPECIFICATION DIVISION 10000 - SPECIALTIES STOREFRONT ILLUMINATED SIGNS • TENANT SIGN CONTRACTOR BLADE SIGN • • TENANT SIGN CONTRACTOR INTERIOR SIGNS LOGO SIGNS • • INTERIOR GRAPHICS BY TENANT VENDOR "COMING SOON" SIGN 0 0 INTERIOR GRAPHICS BY TENANT VENDOR EMPLOYMENT "NOW HIRING" SIGNS D 0 TOILET ACCESSORIES (OTHER THAN NOTED BELOW) • TOILET ACCESSORIES : PAPER TOWEL HOLDER, 0 • LANDLORD TO INSTALL TOILET PAPER HOLDER, SOAP DISP. STORAGE CABINET • • LANDLORD TO INSTALL KOALA CHANGING STATION 0 0 TOILET ROOM UTILITY CABINET 0 LANDLORD TO INSTALL H.G. GRAB BARS • ACCESSIBILITY SIGNAGE 0 • WHERE REQUIRED 100 SALES AREA 3301 5.F. 30 110 YE5 101 HALLWAY 108 5.F. 0 0 NO 102 H.G. TOILET ROOM WOMENS 58 S.F. O 0 NO 103 H.G. TOILET ROOM MENS 64 S.F. 0 0 NO 104 OFFICE 13 S.F. 100 I NO 105 STOCK ROOM 316 S.F. 300 2 NO FIRE EXTINGUISHERS DIVISION 11000 - EQUIPMENT SHOPPER TRACK 0 0 INSTALL BY TENANT VENDOR SECURITY SYSTEM 0 0 0 G.G. TO COORDINATE WITH CHECKPOINT POS EQUIPMENT "CASH RESISTERS" 0 0 0 INSTALL BY TENANT VENDOR COMM WORKS, CONTRACTED BY G.G. COMPUTER SYSTEMS 0 0 0 INSTALL BY TENANT VENDOR GOMM WORKS, CONTRACTED BY G.G. TOTAL: 4,000 S.F. 112 YES REFRIGERATOR / MICROWAVE / LOCKERS / BREAK TABLE 0 • SAFE 0 0 BOLT TO FLOOR WITH EXPANSION ANCHORS EGRESS WIDTH PER OCCUPANT: TABLE 1 005.1 INCHES PER PERSON = 17 INCHES (REQUIRED) FRONT: DOORS = 68" CLEAR REAR: = 34" CLEAR =102" CLEAR Exception #2 Not located less than dimension of the area being served. AUDIO EQUIPMENT AND SPEAKERS 0 0 INSTALL BY TENANT VENDOR 1.) EGRESS COMPONENTS (WITH SPRINKLERS) 0.15 INCHES PER OCCUPANT x 112 OCCUPANTS 2.) ACTUAL WIDTH PROVIDED THROUGH THROUGH FRONT AREA (PAIR 3' -0:" 3J ACTUAL WIDTH PROVIDED THROUGH THROUGH REAR (I) 3' -0" DOOR TOTAL EGRESS WIDTH PROVIDED: 1015.2.1 TING EXIT ACCESS DOORWAYS: one third of the overall diagonal DIVISION 12000 - FURNISHINGS GASHDESK 0 0 FLOOR FIXTURES • SURFACE MOUNT WALL STANDARDS • HARDWARE AND BRACKETS FOR STANDARDS 0 0 ROLLING SAFETY LADDER • • HARDWARE STORAGE UNIT • • OFFICE COUNTERS • • toms kom 1016.1 MAXIMUM TRAVEL: 250 feet sprinklered 1011.1 MINIMUM NUMBER OF EXITS: I -500 Occupants / 2 Exits required le 2 PROJECT babies and kids SOUTHCENTER SQUARE 17250 SOUTHCENTER PKWY TUKWILA, WA AREA 4,000 SQ/FT TENANT SPACE No. 144 PROJECT KEY PLAN GARTERS SOUTHCENTER SQUARE TUKWILA, WA 1 1S 188 SPACE NO. 144 rving Customers PROVIDED 2 soulrormem P,Au .110 KOLIAMO tb.LIZIEWILION PETW. 'tnta f:tfoomfgat l�.J ti''tItui .Roszontot stAtg-ittOWIlltbtirithe4 K' tY Mtn Sid DRAWING INDEX ARCHITECTURAL G I . I TITLE, INDEX, KEY PLAN, DATA G I.2 DOOR SCHEDULE, DOOR CONTRACTOR NOTES FXLE C Y Permit No. E 01 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fi :j Copy < Coll � 'ons is acknowledged: By Date: Soulhanter r City Of Tukwila BUILDING DIVISION No changes shall be made to the scope Tukwila Building Division. OTE. evisions will require a new plan submittal z nil may include additional plan review fees. RESPONSIBILITY SCHEDULE, PROJECT TYPES AND DOOR HARDWARE, GENERAL A0.1 LEASEOUTL I NE FLOOR AND STRUCTURE PLAN AI.I CONSTRUCTION PLAN (LANDLORD WORK) AI.2 FLOOR FINISH PLAN / FINISH SCHEDULE / ROOM FINISH SCHEDULE Al.3 WALL STANDARDS INSTALLATION PLAN A1.4 FLOOR FIXTURING / MILLWORK PLAN A2.I REFLECTED CEILING PLAN A3.I STOREFRONT ELEVATIONS, DETAILS, EXTERIOR SIGNS A3.2 SALES AREA, ELEVATIONS, KEY PLAN A5.5 TOILET ROOM, PART PLAN ELEVATIONS A3.4 STOCKROOM OFFICE, PART PLAN, ELEVATIONS A4.1 INTERIOR SECTIONS AND DETAILS A4.2 INTERIOR SECTIONS AND DETAILS A5.I STOCKROOM SHELVING a DETAILS A6.I ROOF PLAN / HVAG UNIT INSTALLATION M.E.P. ENGINEERING El E2 E3 E4 E5 MI M2 PI FLOOR PLAN LIGHTING WORK FLOOR PLAN - MISC. ELECTRICAL WORK ELECTRICAL DETAILS LOW VOLTAGE DIAGRAMS ELECTRICAL SPECIFICATIONS FLOOR PLAN - MECHANICAL WORK MECHANICAL SPECIFICATIONS FLOOR PLAN - PLUMBING WORK REVIEWED FOR COMPLIANCE WITH NFPA 70 -NEC DEC 22 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKVOLA DEC 1:.1 2009 PERMIT CENTER °1-cri°H DATE: 11/15/09 JOB NO: 09 -066 DRAWN: STAFF CHECKED: KB KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 REGISTERED ARCHITECT KR4NETH L. BUTTS STATE OF WASHINGTON (ADDTti D• E • 5 • I • G• N 225 OAKLAND RAOD, SUITE 105 TEL: (860)183 -5610 SOUTN WINDSOR, CT 06014 FM: (860)183 -5680 W a- i m D co U O Z � Uco w < � O -r o tz I— o : U D LO ® 1� 0_ cn I— co 41• V SHEET TITLE SCALE NONE C1.1 dl ma C l0 STORE NUMBER SHEET NUMBER #TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/1/09 'EV -ISSUE DATE 'c'- ISSUE DATE 'D'- ISSU, DATE 11Th SHEET TOTAL AREA 4,000 Sq. F _ . - , UR - CHEDULE (FIXTURE INDICATED WITH CLOUD BELOW ARE BY LANDLORD - ACCENT LTG. BY TENANT) SYM MARK DESCRIPTION MFG CATALOG# LAMP TYPE VOLTAGE MOUNTING REMARKS 2 FLUORESCENT FIXTURE (2) LAMP HIGH • TPUT T -5 METALUX 2AG- 25414T5 -UNV (2) 54W/T -5 3500K UNIV RECESSED SUPPLIED /INSTALLED BY L.L. 0 .. 4 FLUORESCENT FIXTURE (2) LAMP HIGH • ■ TPUT T -5, WITH EMERGENCY BALLAST AND ci0 MINUTE BATTERY BACK -UP METALUX 2AG- 254WT5 -UNV (2) 54W/T -5 3500K UNIV RECESSED SUPPLIED /INSTALLED BY L.L. w 2 FLUORESCENT FIXTURE W H PRISMATIC DIFFUSER METALUX 2GR&- FA232A - UNIV -EBBI (2) 32W -T8 UNIV RECESSED SUPPLIED /INSTALLED BY L.L. 0 4 FLUORESCENT FIXURE WITH PRISMATI IFFUSER WITH EMERGENCY BALLAST AND q0 MIN. BATTERY METALUX 2688- FA232A - UNIV -EM -EBBI (2) 321 -T8 UNIV RECESSED SUPPLIED /INSTALLED BY L.L. • B SEMI RECESSED WALL WASH FIXTURE CON -TECH RA841OMHE 10W/EB -II UNIV RECESSED TENANT SUPPLIED /INSTALLED BY G.G. h� BIM CON-TECH GTL701�WW -P -LF- 100 - I1V 7 0W/E D -17 UNIV TRACK MOUNT TENANT SUPPLIED /INSTALLED BY G.G. TRACK MOUNTED METAL HALIDE WALL WAS' ICR, MOUNTED IN SINGLE CIRCUIT TRACK, COLOR WHI TE a 2) LAMP FLUORESCENT STRIP METALUX SNF -I32- UNV -EB81 (I) 321^11-8 RUBBER COATED SHATTER PROOF LAMPS UNIV SUSPENDED SUPT 'LIED /INSTALLED BY L.L. 1 I - • EDGE -LIT EXIT 516N NAVILITE NXESB SERIES � A INCLUDED UNIV UNIVERSAL SUPPLIED /INSTALLED BY L.L. *Zig qO MIN BATTERY BACK -UP HOARD LEA EXIT SIGN q0 MIN BATTERY BACK -UP ASTRALITE TP- U- R -W -EM INCLUDED UNIV UNIVERSAL SUPPLIED /INSTALLED BY L.L. 11■ � ITH c10 HEAD EMERGENCY WITH q0 MIN BATTERY BACK -UP HI HL -qO -DL INGULDED UNIV SURFACE SUSPENDED SUPPLIED /INSTALLED BY L.L. SEE PLAN FOR LOCATION 8 AUDIO SPEAKERS REGESSED TENANT SUPPLIED /INSTALLED BY 6.C. 0 NOTE: SCE ARCHITECTURAL RCP FOR LIGHT FIXTURE QUANTITIES NEW PANEL " A " (BY LL) CONNECT EMERGENCY FIXTURES IN REAR AREAS TO SAME CIRCUIT AS GENERAL LIGHTING AHEAD OF LOCAL SWITCHING IN ACCORDANCE WITH N.E.C. AS REQURED FLOOR PLAN - LIGHTING WORK SCALE. vv • rm +46 AFF 0 0 DAY LIGHTING I 0 2 -GANG LIGHT SWITCH - COVERPLATE 0 S LIGHTING I 0 0 LIGHTINSALES G I I LIGHTIN SALES G PROVIDE PERMANENT, TYPED LABELS AS SHOWN. SALES LIGHTING SWITCHING DETAIL NOT TO SCALE DAYLIGHTING REQUIREMENT 6 -GANG LIGHT SWITCH COVERPLATE I ACCENT I LIGHTING ACCENT LIGHTING -WITCH BANK -SEE SWITCHING DETAIL ABOVE A" 1,3 -15 A"5 -7 - 1 5 RUN EXTRA WIRE FOR GROUND (BY LL) (TYPICAL) SWITCH CONCEALED FROM VIEW (BY LL) J -BOX FOR SIGN (BY LL) J LANDLORD WORK UNDER LANDLORD PERMIT CLARIFICATION OF LOCATION DAYLIGHTING REQUIREMENT CURRENT LIMITING DEVICE TO ALLOW MAXIMUM OF 300 W 1...oci4)47 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKIMLA DEC 1 1 2009 PERMIT CENTER DATE: 11/1$/09 JOB NO: 09 -066 DRAWN: STAP CHECKED: DP IV -ISSUE DATE 'G' -ISSUE DATE W w c 0Z� CC 0 WCi) W:C<4 N04:( = N � co SHEET TITLE SCALE 1/4' =1' - O' SHEET NUMBER E1.0 STORE NUMBER #TBD REVISIONS 'A' -ISSUE / 1 \ LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 FLOOR PLAN LIGHTING WORK KEY NOTES (LANDLORD WORK) ®2 PROVIDE (4) 3/4" CONDUITS, (1) DEDICATED P.O.S. CIRCUIT, (1) FOR GENERAL POWER CIRCUIT, (1) CAT 5 CABLE AND PHONE UNE, (1) SPARE. ROUTE CONDUITES AS SHOWN ON PLAN DOWN WALL OR COLUMN, STUB CONDUIT INTO FLOOR MOUNTED JUNCTION BOX. ROUTE FLEXIBLE CONDUIT THROUGH CABINET BASE TO EACH RECEPTACLE. COORDINATE EXACT CONFIGURATION WITH TENANT REP. AND EXACT LOCATION WITH FIXTURE INSTALLER. (ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.) CI PROVIDE 3/4" CONDUIT WITH PULLWIRE FROM CASH /WRAP TO TELEPHONE BACKBOARD IN STOCKROOM. O7 QUAD RECEPTACLE AND J -BOX FLUSH MOUNTED IN WALL AT 72" AFF. ROUTE 1" EMPTY CONDUIT WITH PULLWIRE FROM J -BOX TO 6" ABOVE CEIUNG FOR SPEAKER CABLES. SPEAKER CABLES ABOVE CEILING SHALL BE IN CONDUIT OR SHALL BE PLENUM RATED. VERIFY SOUND SYSTEM EQUIPMENT AND REQUIREMENTS WITH SYSTEM SUPPLIER. ® PROVIDE A QUAD RECEPTACLE, GENERAL QUAD RECEPTACLE, FOR GENERAL PURPOSE POWER AT THE RECEMNG DESK, LOCATED AT 3' -2" A.F.F. 0 DUPLEX IG RECEPTACLE FLUSH MOUNTED VERTICAL AT 10' -0" AFF FOR SECURITY SYSTEM. 10 SUPPLY AND INSTALL THE FOLLOWING SERVICE BELL SYSTEM. a) EDWARDS #852 PUSHBUTTON MOUNTED AT 48" AFF AT REAR DOOR b) EDWARDS #88 -50 TRANSFORMER c) EDWARDS #340 -4G5 BELL MOUNTED ABOVE COORIDOR CEIUNG d) EDWARDS #340 -4G5 BELL MOUNTED ABOVE CASH/WRAP CEIUNG 11 FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB -IN AND EXTEND AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4" PLYWOOD BACKBOARD FOR MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT, SIZE AND SECURE AS REQUIRED. PROVIED ISOLATED GROUND DUPLEX RECEPTACLE FOR POWER TO TELEPHONE EQUIPMENT. BY LANDLORD. 10 PROVIDE A QUAD IG RECEPTACLE FOR COMPUTER SYSTEM, LOCATED AT 3' -2" A.F.F. 14 RJ31x JACK FOR CHECKPOINT /SECURITY SYSTEM. KEY NOTES (TENANT WORK) ® THE CIRCUITES USED TO POWER THE CASH REGISTERS /COMPUTERS SHALL NOT BE USED FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL, AND ISULATED GROUND WIRES MINIMUM SIZE #12 AWG SHALL BE RUN TO THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE CONDUIT FOR GROUNDING AS THIS MAY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. RECEPTACLES SHALL BE HUBBEL #IG -5362 ORANGE. ® DEVICES SURFACE MOUNTED ON CABINET INTERIOR AT 12" AFF. FIELD VERITY LOCATION OF CABINET SHELVING PRIOR TO INSTALLATION. ® RUN 2 CAT 5 NETWORK CABLES FROM RJ45 JACKS AT CASHWRAP TO RJ45 JACKS AT RECEMNG TABLE IN STOCKROOM. PROVIDE 18" CABLES AT EACH LOCATION FOR CONNECTION OF CASH /WRAP HUB AND RECEIVING COMPUTER. CABLES TO BE PLENUM RATED IF NOT INSTALLED IN CONDUIT. MOUNTED AT 3' -2" A.F.F. (ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.) ® TGC TO RUN AN EXTRA CABLE THROUGH THE CEIUNG AND LEAVE IT COILED FOR FUTURE USE. ALARM SYSTEM WIRING TO BE BY VENDOR. 0 JUNCTION BOX FOR SHOPPERTRAK ORBIT. COORDINATE EXACT LOCATION IN FIELD WITH SHOPPERTRAK REPRESENTATIVE. PROVIDE (1) CAT 5 PLENUM RATED CABLE IN 3/4" CONDUIT FROM ORBIT LOCATION AT FRONT DOOR TO CONTROLLER LOCATION AT MAIN TEL /DATA BACKBOARD. CABLE IS BELDEN #1701k LEAVE SUFFICIENT SLACK AT EACH J -BOX FOR CONNECTION (15' -0" MIN. PER MANUFACTURER'S RECOMMENDATIONS) (ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.) LANDLORD WORK UNDER LANDLORD PERMIT ZONE ADDRESSABLE MODULE (TYPICAL) STROBE ONLY (TYPICAL FOR 3) NEW HORN /STROBE MOUNTED 80" TO BOTTOM OF DEVICE OR 6" FROM CEIUNG-WHICHEVER IS GREATER (TYPICAL FOR 6) EOLR SPRINKLER TAMPER SWITCH EOLR SPRINKLER FLOW SWITCH 18 TSP (TYPICAL SIGNALING DEVICES S S S • • V ♦ • • V • ♦ • • A • • • #12 CU-' AWG I-NEW PULL STATION (TYPICAL FOR 3) (MOUNTED 48" MAX A.F.F. ® ® TO CENTERLINE OF DEVICE) EOLR t _ NEW CEIUNG MOUNTED ;FOLK SMOKE DETECTOR (TYPICAL FOR 6) DUCT MOUNTED SMOKE DETECTOR (TYPICAL FOR 2) INITIATING DEVICES FIRE ALARM SCHEMATIC NOT TO SCALE EXTEND AND CONNECT TO LANDLORD MAIN FIRE ALARM SYSTEM AS REQUIRED. COORDINATE WITH LANDLORD ALL CONNECTIONS TO LANDLORD'S SYSTEM. (BY U_) 11 \- FIRE ALARM INTERFACE FOR CONNECTION TO LANDLORD'S CENTRAL FIRE ALARM SYSTEM TO 4 TTB ® "A "26,28 "A"22 DEDICATED DUPLEX RECEPTACLE HUBBELL#IG -5362 ORANGE FOR CASH REGISTER COMPUTER AT 12" AFF /_, CASH DESK WIRING SCALES 1/4• - T ENERAL USE QUADPLEX HUBBELL #5362 -WHI AT 12" AFF FLEXIBLE CONDUIT IN CABINET BASE PUSH BUTTON NEW PANEL "A" (BY LL) RECEPTACLE FOR REFRIGERATOR (15" A.F.F.) RECEPTACLE FOR MICROWAVE (36" A.F.F.) UNIT HEATER SUSPENDED FROM ABOVE FLOW AND TAMPER SWITCH SHALL BE -� INSTALLED AS PART OF FIRE ALARM SYSTEM BY LANDLORD- VERIFY EXACT LOCATION AND MOUNTING REQUIREMENTS IN FIELD. IC - IC -LL "A "14,16 "K35 Td BUZZER r A" 12,18 75 "A"37,39,41 - #12- 1/2"C. "A"33.•• SEE SHEET E4 FOR SCHEMATIC LAYOUT OF LOW VOLTAGE INTERFACES DETAIL UNIT #2 ON ROOF FIRE ALARM IN RFACE (BY LL) SPEAKER (TYPICAL) FLOOR PLAN - MISCELLANEOUS SCALE 1/4• - 1-0 SEE CASH DESK DETAIL THIS SHEET FOR WIRING INFORMATION IN THIS AREA SPEAKER WIRE (TYPICAL) NEW DISCONNECT SWITCH #1 ON ROOF (BY LL) (60/50, NEMA 3R) ELECTRIC WORK "A "32,34,3 3-#8-1/2"C. FURNISH AND INS NEW PULL STATION (TYPICAL -BY LL) - FURNISH AND INSTALL NEW ACCESSABLE SMOKE DETECTOR IN RETURN DUCT. PROVIDE AND INSTALL WIRING 0 FAN INTERLOCK. (TYPICAL -BY LL, 15' -10" -ALL DEVICES SHALL BE A MINIMUM 75 CANDELLA AND SHALL COMPLY WITH NFPA 72 AND ALL OTHER STATE AND LOCAL REQUIREMENTS. RECEPTACLE MOUNTED ABOVE SHOW WINDOW (TYPICAL FOR 2 -BY LL) LANDLORD WORK UNDER LANDLORD PERMIT 0`l- o79y REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 1 2009 PERMIT CENTER DATE: 11/18/09 JOB NO: m9 -066 DRAWN: 8tAPP CHECKED: PP Q - 0 SI -ISSUE DATE 'C'- ISSUE PATE Nri C 5 • tu E STORE NUMBER itTBD REVISIONS A' ' A LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 SHEEP TITLE FLOOR PLAN MISCELLANEOUS ELECTRIC WORK SCALE 1/4' =1' - O' SHEET NUMBER E2.O PANEL NEW PANEL "A" BY LL LUGS MAIN 225 AMP 120/208 VOLT 3 PHASE 4 WIRE BREAKER 200 AMP USE CKT. NO. LOAD BKR SIZE A B C BKR SIZE LOAD CKT. NO. USE SALES AREA LIGHTS 1 1188 20 1200 2 SIGN !, i..� A• IIII 01 1 0 011 A. �M x. in" N 1�� am r.a ^ ••� VIER PI ..A 011 ill 01 011 di 3 972 394 4 STORE FRONT LIGHTS 5 1080 394 6 7 864 280 8 TRACK LIGHTING ACCENT LIGHTS 9 700 360 10 SHOW WINDOW RECPT. 11 630 1200 12 MICROWAVE REAR AREA LIGHTS 13 714 180 14 SECURITY SYSTEM IA EM /NIGHT LIGHTS 15 727 500 16 TTB RECPT. ..� T.E. FANS 17 180 660 18 REFRIGERATOR REC. DESK IG 19 360 — 20 SPARE E A REC. DESK RECPT. 21 360 1440 22 CASH DESK RECPT. ••� HOT WATER HEATER 23 1500 360 24 HVAC RECPT. MANAGERS DESK IG 25 500 1000 26 CASH REGISTER MANAGERS DESK RECPT 27 36 0 100 28 SOUND SYSTEM 29 500 — 30 SPARE SHOPPER TRACK SYSTEM 31 1000 4 � /3 5200 32 GENERAL RECPT. 33 1440 5200 34 A.C. UNIT # TOILET ROOM RECPT. 2 � /3 • 37 1666 3 /3 3543 38 UNIT HEATER 39 1666 3543 40 A.C. UNIT #2 41 1666 3543 42 TC1 TC1 TC1 TC1 TC2 TC2 * " *" INDICATES PANEL LOCKS "TC#" INDICATES TIME CLOCK 2" RIGID INSULATION CONCRETE ENCASED ELECTRODE PANEL DIRECTORY PHASE A: 17695 WATTS PHASE B: 18662 WATTS PHASE C: 17273 WATTS TOTAL: 53630 WATTS GROUNDING SHALL CONSIST OF COPPER CONDUCTORS IN CONDUIT WITH BOLTED, OR BRAZED, CONNECTION TO EACH ILLUSTRATION BELOW FOR THE NEUTRAL. GROUNDING AND BONDING SHALL COMPLY WITH NEC ARTICLES 230 & 250. ALL METALLIC RACEWAYS SHALL BE GROUNDED 1 b 1 BUILDING STEEL WATER (2) -3/4 "X10' SERVICE GROUND RODS PIPING BALANCE: 7.44 % GROUND PER NEC —\ SPECIAL NOTE: IG AND GFI RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSLUATED GREEN GROUND WIRE, THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPUCED BETWEEN THE DEVICE AND THE PANEL GROUND BUS TC3 TC2 TC2 TC3 * SUGGESTED SERVICE GROUND DETAIL NOT TO SCALE GALVANIZED SHEET METAL HOOD FILL VOID WITH FIBERGLASS INSULATION 1" CONDUIT ROOF DECK — (VERIFY EXACT CONSTRUCTION AND PENETRATE AS REQUIRED) SHEET METAL OR FLEX —TUBE COLLAR WOOD NAILER— PROVIDE FASTNERS 24" O.C. MAX. 26 GA. COUNTERFLASHING 12" MIN. ROOF FELTS AND FLASHING CONDUIT THRU ROOF DETAIL NOT TO SCALE PAWL "A" FEEDER LCL signage, general lighting, aash re(lister, unit heater, ett. haru•windouu or entnf lighting (at shouuwindcw) track lighting s tra& lighting(shatrrwin x" a.c. equipment(rt% ahu, cu, etc.)- 484 volt x" a a equipment(rtu, ahu, cu. etc.)- 208 volt Sub Total NON LCL water heater. sensormatic, traffic counter, misc., etc, "r recep tact es ""s how window lighting requirement in feeder only) Sub Total TOTAL INPUT 280 0 75.0:I x#1.36 1$ a 723 1Z 27 FACTOR 1.25 1.25 75.03 360.23 1 13t57P 357 0 1200 0 26227 12253 5443 30 VA 41355 21218 62573 4:10 wR - total amperage egauls fQ 208 volt • -vtal amperage egavls 75.3 173,7 Track . . Ming calculated per 2005 NEC .,`Srti cle 220 43(B) " MCA used includes 125% of largest mrltgr per 2445 NEC Aril ole220.18(A) xxx Receptacles aaloulated per 2605 NEC Article 220.44 xxxx $ GRADE 1st 10kwa 103% All other 50%6 200 VA per LF ofshouu- rnindow minus actual lighting NEW METER FOR SPACE BY LL EX. METER SOCKET FOR SPACE PROVIDED BY LL 0 0 EX. 200 AMP DISCONNECT FOR SPACE PROVIDED BY LL r, RISER DIAGRAM NOTES 1. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND ALL BRANCH DEVICES AS REQUIRED. 2. CONTRACTOR TO MAINTAIN ALL REQUIRED CLEARENCES PER ARTICLE 110 -26 NEC APPROX. 125' -0" TIMECLOCK #1 FOR AUTOMATIC LIGHTING CONTROL /SHUTOFF IN ACCORDANCE WITH THE 2006 WASHINTON STATE ENERGY CODE TIMECLOCK #1 FOR AUTOMATIC LIGHTING CONTROL /SHUTOFF IN ACCORDANCE WITH THE 2006 WASHINTON STATE ENERGY CODE TYPE O CKT V I SERVICE TO SPACE TO BE 120/208 VOLT, 3PH, 4W., 200 AMP BY LANDLORD (4— #3/0 -2" C. MIN. —SEE NOTE 3 BELOW) SYMBOLS AND ABBREVIATIONS RECESSED INCANDESCENT FIXTURE SINGLE POLE SWITCH DUPLEX WALL RECEPTACLE QUADRAPLEX ISOLATED GROUND RECEPTACLE GROUND FAULT QUADRAPLEX WALL RECEPTACLE QUADRAPLEX WALL RECEPTACLE WEATHERPROOF RECEPTACLE JUNCTION BOX TELEPHONE OUTLET TELEPHONE /DATA OUTLET DATA OUTLET TELEPHONE CONDUIT T.T.B. TELEPHONE TERMINAL BOARD FIRE ALARM SYMBOLS AND ABBREVIATIONS Q SMOKE DETECTOR (SIMPLEX #4098 -9714) DUCT SMOKE DETECTOR (SIMPLEX #4098 -9756) PULL STATION (SIMPLEX #4099 -9001) O P S 75 HORN /STROBE (EQUAL TO SIMPLEX SERIES #4904 -9351 — COORDINATE 1� EXACT REQUIREMENT FOR DEVICES WITH SIMPLEX) S INDICATES CANDELLA RATING OF DEVICE V75 SPEAKER STROBE (EQUAL TO SIMPLEX SERIES 4903 -9451 — COORDINATE EXACT REQUIREMENT FOR DEVICES WITH SIMPLEX) CANDELLA RATING OF DEVICE 3— #8- 1/2"C. MIN. (BY LL) TC1 TC2 ELECTRIC RISER DIAGRAM NOT TO SCALE do- 3- #8- 1/2"C. MIN. (BY LL) TC3 --r. 2,8 NEW PANEL "A" 3. AT TIME OF DESIGN 1 3/4" CONDUIT PRESENTLY EXISTS TO SPACE. SERVICE SIZE, WIRE SIZE, TYPE, AND INSTALLATION IS UNKNOWN. CONTRACTOR TO VERIFY EXISTING SERVICE AND INSTALLATION TO SPACE IS ADEQUATE WITH THE NEW DESIGN MINIMUM SERVICE SIZE, WIRE SIZES, ETC SHOWN ABOVE IN THE DIAGRAM. IF ANY PORTION OF EXISTING INSTALLATION IS INADEQUATE PER THE NEW DESIGN, CONTRACTOR SHALL INSTALL TO ACCOMODATE THE DESIGN. (BY LL) 0 S � i S S �I S EX $OC NEW DISCONNECT SWITCH #1 [4 — ON ROOF BY LL (60/50, NEMA 3R MIN.) NEW DISCONNECT SWITCH #2 ON ROOF BY LL (60/45, NEMA 3R MIN.) NEW TIME CLOCK (TYPICAL FOR 3) PUSHBUTTON [�B BUZZER A TRANSFORMER MCA MINIMUM CIRCUIT AMP MOCP MAXIMUM OVERCURRENT PROTECTION CONDUIT ABOVE FLOOR CONDUIT BELOW FLOOR > MARKS INDICATE NUMBER OF WIRES HOME RUN CONDUIT EXISTING TO REMAIN EXR EXISTING RELOCATED SHTR SHOPPERTRACK D DATA T TELEPHONE F FAX M MODEM OCCUPANCY SWITCH LL LANDLORD INSTALLED l e— NEW A.C. UNIT #1 ON ROOF (BY LL) NEW A.C. UNIT #2 ON ROOF (BY LL) LANDLORD WORK UNDER LANDLORD PERMIT A CLARIFICATION FOR MAIN LUG ONLY TIMECLOCK #1 FOR AUTOMATIC LIGHTING CONTROL /SHUTOFF IN ACCORDANCE WITH THE 2006 WASHINTON STATE ENERGY CODE EtD O7'I REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIIA DEC 1 2009 PERMIT CENTER DATE: 11/1/3/09 JOB NO: 09 - 066 DRAWN: STAFF CHECKED: DP W ir a W oo 0 Z� CC 0 W wi<4 Z kii0<f±' O � � W - ISSUE /1 DATE '8' -ISSUE DATE 'C' -ISSUE DATE STORE NUMBER itTBD SHEET TITLE ELECTRICAL DETAILS SCALE 1/4 " =1' - 0 * SHEET NUMBER E3.0 C .0 LL d m O REVISIONS LANDLORD WORK UNDER LANDLORD PERMIT 12/6/09 IA CKUP MDT NOTE: REGISTER 1 UNE 2 HUB CASHWRAP REGIS1ER 2 8" RADIUS PROVIDE COVER PLATES COLOR SELECTED BY ARCHITECT REGISTER 3 CAM OWP PAS LKE 1 ao K1fOCM LFE 2 LEXMARK PRINTER TELEPHONE L94E 1 BUSHING WITH PULL STRING STUBBED TO ACCESSIBLE LOCATION ABOVE CEILING (1) 1" CONDUIT TO ACCESSIBLE SPACE IN CEILING (2) GANG DEEP BACK BOX WITH SINGLE GANG EXTENSION BOX 18" AFF- VERIFY WITH ARCHITECT SCANNER BACK OFFICE PC PRINTER MANAGER'S OFFICE RECEIVING DESK LRE 2 DIAL BAdO P FAX SCHEMATIC LAYOUT OF LOW VOLTAGE INTERFACES NOT TO SCALE TELEPHONE /DATA RISER DETAIL NOT TO SCALE CEILING FLOOR ROUTER TYPICAL WHEN ANY OF THE FOLLOWING SYMBOLS Y V AND SZ ARE SHOWN ON PLAN. PROVIDE AS SHOWN ABOVE MODEM MANAGER'S DESK Yfit KFF1fE It FAX AMINE TELCO DEIAARK 56K OR I A RE RA -31X H FOR ALAR4 EEG.% DESK UNE 2 FROM TM: RECEIVING DESK HAS 4 BOXES. (1) RJ45 FOR LINK TO CASH WRAP, (1) FOR UNE 1, (1) FOR UNE 2, FOR 56 K CIRCUIT UNE 1 GOES TO THE MANAGER'S OFFICE, THE RECEIVING DESK AND THE CASH WRAP VIA THE RECEIVING DESK. UNE 2 GOES TO THE CASH WRAP AND THE RECEIVING DESK UNE 3 GOES TO THE MANAGER'S OFFICE FAX MACHINE RECEIVING DESK DATA/TELEPHONE FACEPLATE REQUIREMENTS REGISTER 1 L2 # # ## rl�r i= 1 r POS1 POS2 I t RECEIVING DESK SHOPPERTRAK f POWER DATA J 1 I REGISTER4 1 1 ® J MANAGER'S OFFICE C 1 I ELO 019 )-I REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKW ILA DEC 1,`1 2009 PERMIT CENTER DATE: II/15 /09 JOB NO: 09 DRAWN: STAFF CHECKED: DP 1 ' Q U W O- CC cc a Oz T CO W 00 W=<4 • W �® voaZ CD I- O L : U N W co r 1— CA 4.0 co V SHEET TITLE STORE NUMBER %TBD REVISIONS 'N.-ISSUE/1\ LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 'IS' -ISSUE DATE 'C' -I88UE DATE LOW VOLTAGE DIAGRAMS SCALE 1/4 * =1' - 0" SHEET NUMBER E4.0 C 1 L1 #### I I I L2 #### -1 CIRCUIT I ... , 1 POS 1 POS 2 1 - I 1 (cam) IA CKUP MDT NOTE: REGISTER 1 UNE 2 HUB CASHWRAP REGIS1ER 2 8" RADIUS PROVIDE COVER PLATES COLOR SELECTED BY ARCHITECT REGISTER 3 CAM OWP PAS LKE 1 ao K1fOCM LFE 2 LEXMARK PRINTER TELEPHONE L94E 1 BUSHING WITH PULL STRING STUBBED TO ACCESSIBLE LOCATION ABOVE CEILING (1) 1" CONDUIT TO ACCESSIBLE SPACE IN CEILING (2) GANG DEEP BACK BOX WITH SINGLE GANG EXTENSION BOX 18" AFF- VERIFY WITH ARCHITECT SCANNER BACK OFFICE PC PRINTER MANAGER'S OFFICE RECEIVING DESK LRE 2 DIAL BAdO P FAX SCHEMATIC LAYOUT OF LOW VOLTAGE INTERFACES NOT TO SCALE TELEPHONE /DATA RISER DETAIL NOT TO SCALE CEILING FLOOR ROUTER TYPICAL WHEN ANY OF THE FOLLOWING SYMBOLS Y V AND SZ ARE SHOWN ON PLAN. PROVIDE AS SHOWN ABOVE MODEM MANAGER'S DESK Yfit KFF1fE It FAX AMINE TELCO DEIAARK 56K OR I A RE RA -31X H FOR ALAR4 EEG.% DESK UNE 2 FROM TM: RECEIVING DESK HAS 4 BOXES. (1) RJ45 FOR LINK TO CASH WRAP, (1) FOR UNE 1, (1) FOR UNE 2, FOR 56 K CIRCUIT UNE 1 GOES TO THE MANAGER'S OFFICE, THE RECEIVING DESK AND THE CASH WRAP VIA THE RECEIVING DESK. UNE 2 GOES TO THE CASH WRAP AND THE RECEIVING DESK UNE 3 GOES TO THE MANAGER'S OFFICE FAX MACHINE RECEIVING DESK DATA/TELEPHONE FACEPLATE REQUIREMENTS REGISTER 1 L2 # # ## rl�r i= 1 r POS1 POS2 I t RECEIVING DESK SHOPPERTRAK f POWER DATA J 1 I REGISTER4 1 1 ® J MANAGER'S OFFICE C 1 I ELO 019 )-I REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKW ILA DEC 1,`1 2009 PERMIT CENTER DATE: II/15 /09 JOB NO: 09 DRAWN: STAFF CHECKED: DP 1 ' Q U W O- CC cc a Oz T CO W 00 W=<4 • W �® voaZ CD I- O L : U N W co r 1— CA 4.0 co V SHEET TITLE STORE NUMBER %TBD REVISIONS 'N.-ISSUE/1\ LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 'IS' -ISSUE DATE 'C' -I88UE DATE LOW VOLTAGE DIAGRAMS SCALE 1/4 * =1' - 0" SHEET NUMBER E4.0 LANDLORD WORK UNDER LANDLORD PERMIT CLARIFICATION ELECTRICAL EQUIPMENT AND MATERIAL UNIT HEATER: TRANE #UHEC- 052AACA, HORIZONTAL, 5 KW, 208 VOLT, 3 PH., 60 HZ, COMPLETE WITH HORIZONTAL WALL /CEILING SWIVEL MOUNTING BRACKET, 24 VOLT CONTROL TRANSFORMER AND ROOM THERMOSTAT. . PANEL A: SQUARE D TYPE NQODCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3 PH., 4 WIRE. A.C. UNIT DISCONNECT SWITCH: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 60 AMP, 240 VOLT, FUSIBLE, WITH FUSES AS SHOWN IN PLAN AND NEMA 3R ENCLOSURE. SQUARE D #H322. A.C. UNIT DISCONNECT SWITCH: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 60 AMP, 240 VOLT, FUSIBLE, WITH FUSES AS SHOWN IN PLAN AND NEMA 3R ENCLOSURE. SQUARE D #H322. TIME CLOCK #1: TORK #W -4001, 4PST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH MANUAL OVERRIDE AND 24 HOUR RESERVE POWER FEATURE IN ACCORDANCE WITH THE 2001 IECC. TIME CLOCK #2: TORK #W -300L, 3PST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH MANUAL OVERRIDE AND 24 HOUR RESERVE POWER FEATURE IN ACCORDANCE WITH THE 2001 IECC. TIME CLOCK #3: DPST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH RESERVE POWER FEATURE. TORK #W220L. RECEPTACLES: HUBBELL #5362. GROUND FAULT RECEPTACLES: HUBBELL #GF_5362. ISOLATED GROUND RECEPTACLES: HUBBELL #IG- 5362. "QUAD" RECEPTACLES: TWO (2) HUBBELL #5362 DUPLEX RECEPTACLES IN A COMMON JUNCTION WITH A 4 GANG COVER PLATE. CASH REGISTER RECEPTACLES: TWO (2) HUBBELL #IG -5362 DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. TELEPHONE /MODEM OUTLETS: HUBBELL TYPE RJ11 WITH COVER PLATE. DATA OUTLETS: HUBBELL TYPE RJ45 WITH COVER PLATE. SINGLE POLE SWITCHES: HUBBELL #HBL -1221. THREE WAY SWITCHES: HUBBELL #HBL- 1223_I. OCCUPANCY SWITCHES: LEVITON, MODEL #PR180 -1 LA OR EQUAL. COVERPLATES: HUBBELL, COLOR TO BE COORDINATED WITH OWNER AND /OR ARCHITECT. PUSHBUTTON: EDWARDS #1786C_B. SIGNAL TRANSFORMER: EDWARDS #596. BUZZERS: EDWARDS #15_OAJ. DUCT SMOKE DETECTOR: SIMPLEX #4098 -9686. PORCELEIN CEILING MOUNTED LAMP HOLDER: GENERAL ELECTRIC, MODEL #GE- 5740 -7 FOR USE WITH SWITCH, COMPLETE WITH 100 WATT TYPE "A" LAMP. ELECTRICAL WORK NOTES 1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS. 2. THE SPACE IS NEW AND HAS NOT PREVIOUSLY BEEN OCCUPIED. REMOVE EXISTING LIGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, WIRE, ETC., NOT REQUIRED FOR THE NEW INSTALLATION. UNUSED FIXTURES SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE. 3. FURNISH AND INSTALL A NEW 120/208 VOLT 3PH., 4W. 200 AMP SERVICE TO THE SPACE FROM THE LANDLORD ELECTRICAL LOCATION, INCLUDING BUT NOT UMITED TOO, MAIN DISCONNECT, METER, METER SOCKET, CONDUIT, WIRING, ETC. 4. NEW SERVICE SHALL BE A PART OF THE ELECTRICAL CONTRACT. COORDINATE ALL REQUIRED WORK AT DISTRIBUTION LOCATION WITH LANDLORD TO ENSURE COMPATIBILITY /ACCEPTABILITY /AVAILABILITY OF SERVICE AS REQUIRED AND INDICATED. IF ANY ISSUES ARISE WITH REGARD TO SERVICE SIZE AND AVAILABILITY OF CERTAIN SIZED DISTRIBUTION EQUIPMENT, CONTACT ARCHITECT AND /OR ENGINEER PRIOR TO BID FOR DISPOSITION. BASE BID SHALL INCLUDE ALL REQUIRED WORK AT LANDLORD'S DISTRIBUTION LOCATION AND SHALL BE COMPLETE IN EVERY ASPECT AS REQUIRED TO ACCOMMODATE NEW SERVICE. NO EXTRAS WILL BE ALLOWED FOR WORK NOT INCLUDED IN BASE BID. 5. FURNISH AND INSTALL ONE (1) 120/208, 200 AMP, 42 CIRCUIT ELECTRICAL PANEL WITH MAIN LUG ONLY. 6. THE CONTRACTOR SHALL FURNISH AND INSTALL TWO (2) NEW A.C. UNITS ON ROOF ABOVE THE SPACE. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL POWER WIRING, CONDUITS, DISCONNECT SWITCHES, OVERCURRENT PROTECTION, ETC. FOR THE NEW A.C. SYSTEMS AS SHOWN AND REQUIRED FOR A COMPLETE INSTALLATION AS REQUIRED. 7. CONNECT ALL CIRCUITS TO PANEL AS REQUIRED. ALL CIRCUITS SHALL BE ARRANGED ON THE PANEL IN STRICT ACCORDANCE WITH THE NUMBERS SHOWN ON THE DRAWINGS. NO VARIATION OR DEVIATION FROM THE DRAWING WILL BE ACCEPTED. ANY CHANGE IN CIRCUITING DUE TO ACTUAL FIELD CONDITION MUST BE APPROVED BY THE ENGINEER PRIOR TO AFFECTING THE CHANGE. ANY WORK PERFORMED ASIDE FROM THAT SHOWN, INDICATED OR IMPLIED MUST BE APPROVED BY THE PROJECT MANAGER AND /OR ENGINEER BEFORE STARTING. ALL UNUSED CIRCUITS SHALL BE UTIUZED AS SPARES. 8. VERIFY SIZE, LOCATION AND WIRING REQUIREMENTS FOR ALL EQUIPMENT WHICH WILL BE UTILIZED. REPORT ANY DISCREPANCIES, FROM THAT CAI I FD FOR ABOVE, TO THE ARCHITECT AND /OR ENGINEER FOR DISPOSITION. 9. MAINTAIN ALL REQUIRED CLEARANCES AT ALL ELECTRICAL EQUIPMENT, INCLUDING, BUT NOT LIMITED TOO DISCONNECT SWITCH(ES) AND ELECTRICAL PANELS, IN STRICT ACCORDANCE WITH N.E.C. ARTICLE 110. RELOCATE ANY /ALL EQUIPMENT AND ASSOCIATED POWER (INCLUDING RECEPTACLES, WIRING, CONDUIT, ETC.) THAT CONFLICTS WITH THE REUSE OF THIS EQUIPMENT IN THEIR PRESENT LOCATIONS AS REQUIRED. CONTACT THE PROJECT MANAGER TO COORDINATE THIS PORTION OF THE WORK IF REQUIRED. 10.TEMPERATURE CONTROL WORK WILL BE A PART OF THE MECHANICAL CONTRACT. ALL CONTROL WIRING SHALL BE IN CONDUIT. 11.FURNISH AND INSTALL NEW TELEPHONE TERMINAL BOARD IN LOCATION SHOWN. NEW TELEPHONE TERMINAL BOARD SHALL BE 12" X 24" PLYWOOD, 3/4" THICK, MOUNTED ON WALL, READY TO RECEIVE TELEPHONE EQUIPMENT. 12.AFTER CONSTRUCTION IS COMPLETE, FIELD VERIFY THE EXTENT OF ALL EQUIPMENT IN ALL AREAS AND ENSURE THAT ALL CONNECTIONS AND OR INTERFACES BETWEEN DEVICES IN THE VARIOUS AREAS OF THE BUILDING ARE MET AS REQUIRED. CONTACT FIELD REPRESENTATIVE TO COORDINATE THIS PORTION OF THE WORK AS APPLICABLE. 13. PROVIDE TEMPORARY WIRING AS REQUIRED WHILE SERVICE IS BEING INSTALLED TO ALLOW FOR LIGHTING AND POWER FOR CONSTRUCTION PURPOSES. WHEN INSTALLING NEW SERVICE, KEEP SHUTDOWN TIME TO A MINIMUM. 14. SEE ARCHITECTURAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE, EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. 15.REFER TO CARTERS RETAIL REQUIRED DELIVERY CONDITION DOCUMENT, SCHEDULE A FOR CLARIFICATION ON ANY ISSUES NOT MENTIONED IN CONTRACT DOCUMENTS. IF CONFLICTS OCCUR BETWEEN CONSTRUCTION DOCUMENTS AND SCHEDULE A, CONTACT THE ARCHITECT AND /OR ENGINEER FOR DISPOSITION PRIOR TO BID OR INSTALLATION. TELEPHONE GENERAL NOTES 1. FURNISH AND INSTALL A 2' X 3' X 3/4" TELEPHONE TERMINAL BOARD WITH DEDICATED RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND FOR USE WITH THE TELEPHONE SYSTEM. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. 2. COMMUNICATIONS CONTRACTOR SHALL INSTALL A COMPLETE AND OPERABLE TELEPHONE SYSTEM. SAID CONTRACTOR SHALL SUPPLY ALL LABOR, PREMISE WIRE, WIRE BLOCKS, TELEPHONE JACKS AND OTHER NECESSARY APPURTENANCES TO COMPLETE IN EVERY DETAIL. 3. SYSTEM SHOWN IS SCHEMATIC AND EXACT LOCATION SHALL BE DETERMINED BY ALL SITE CONDITIONS. 4. TELEPHONE CABLES SHALL BE INSTALLED IN CONDUIT (WHERE REQUIRED) ABOVE THE SUSPENDED CEILING. IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE - CABLING RUN THROUGHOUT STORE IN THE PLENUM AREA SHALL BE SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE - EITHER WAY, ORDERLY RUNS AND ATTACHMENT TO JOISTS ARE REQUIRED. SAID CONTRACTOR SHALL CONFIRM ALL REQUIREMENTS WITH OWNER, GENERAL CONTRACTOR AND LOCAL CODE AUTHORITY BEFORE INSTALLING ANY CABLE. 5. OWNER WILL HAVE A FIVE (5) LINE SYSTEM. COORDINATE ALL REQUIREMENTS WITH THE LOCAL UTILITY. A. LINES 1 THROUGH 5 WILL BE USED FOR VOICE, FAX OR MODEM AS DIRECTED BY THE OWNER. REFERENCES TO NUMBERS 6 -8 (9) ON THE SCHEMATICS ARE FOR OTHER LOW VOLTAGE SYSTEMS IN THE SPACE PROVIDED BY OTHERS. 6. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY TELEPHONE SERVICE FOR USE BY OWNER AND SELF DURING CONSTRUCTION. CONNECTION FEES AND SERVICE FEES SHALL BE PAID BY GENERAL CONTRACTOR. 7. GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER AND LOCAL UTILITY COMPANY (IF REQUIRED) TO SUPPLY THE TELEPHONES THROUGHOUT THE SPACE FOR THE PROJECT. ELECTRICAL WORK NOTES - GENERAL 1. THE ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. 2. ELECTRICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 3. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 4. ELECTRICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 5. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. AT NO TIME SHALL ANY WORK BE UNDERTAKEN WHICH SHALL INTERFERE WITH THE NORMAL OPERATION OF BUSINESS. ANY SHUTDOWN MUST OCCUR AFTER REGULAR BUSINESS HOURS AND MUST BE CLEARED WITH THE MANAGEMENT WITH PROPER PRIOR NOTICE GIVEN TO THE OWNER'S REPRESENTATIVE. 6. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS, OMISSIONS OR DISCREPANCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAIUNG SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 7. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 8. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER /ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 9. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 10.WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 11.ALL WIRE SHALL BE COPPER. MINIMUM SIZE #12 AWG. ALL CONDUCTORS #10 AND SMALLER SHALL HAVE TYPE "THHW" INSULATION. CONDUCTORS LARGER THAN #10 SHALL HAVE TYPE "THHN" INSULATION. 12.ALL WIRE SHALL BE IN CONDUIT AND SHALL BE CONCEALED FROM VIEW. EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES PARALLEL WITH OR PERPENDICULAR TO COLUMN LINES OR BEAMS AND SHALL BE SEPERATED BY AT LEAST 3" INCHES FROM DOMESTIC WATER LINES WHENEVER ALONG SIDE OR ACROSS SUCH UNES. ROMEX IS NOT PERMITTED. FLEXIBLE CONDUIT OR TYPE MC CABLE MAY BE USED FOR FIXTURE AND EQUIPMENT CONNECTIONS ONLY, AND WHERE SO USED SHALL BE GROUNDED WITH A SEPERATE FULL SIZED GREEN GROUNDING CONDUCTOR. FLEXIBLE CONDUIT CONNECTIONS SHALL BE LIMITED TO 3' -O" IN LENGTH. CONDUIT EXPOSED TO WEATHER SHALL BE RIGID. ALL OTHER CONDUIT SHALL BE EMT. CONDUIT FITTINGS SHALL BE COMPRESSION OR THREADED TYPE, USE OF SET SCREW FITTINGS IS NOT ACCEPTABLE. 13.CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT IN UNFINISHED AREAS MAY BE EXPOSED. 14.HOME RUNS OVER 100' IN LENGTH SHALL BE #10 WIRE. 15.CONTRACTOR SHALL ENSURE THAT ENTIRE INSTALLATION IN ACCORDANCE WITH N.E.C. ARTICLE 110 -26 AND THAT ALL REQUIRED OPERATING AND MAINTENANCE CLEARANCES ARE MAINTAINED AND ACCOUNTED FOR. ADJUSTMENTS TO LAYOUT SHOWN TO ACCOMMODATE CLEARANCE REQUIREMENTS SHALL BE DISCUSSED WITH ARCHITECT AND /OR ENGINEER SO AS TO MINIMIZE IMPACT ON OTHER SYSTEMS. CONTACT ARCHITECT AND /OR ENGINEER FOR DISPOSITION. 16.CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND BRANCH DEVICES AS REQUIRED. 17.SEAL ALL PENETRATIONS THROUGH WALLS, CEIUNGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. 18.PROVIDE ENGRAVED BAKEUTE NAMEPLATES FOR ALL ELECTRICAL SERVICE EQUIPMENT INCLUDING DISCONNECT SWITCHES, PANELS, PUSHBUTTONS AND STARTERS. 19.LIGHTING CIRCUITS WHICH ARE SWITCHED AT PANELS SHALL BE FITTED WITH TYPE "SWD" BREAKERS SUITABLE FOR SWITCHING SERVICE. 20.FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORY(IES). IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. FURNISH AND INSTALL AN ENGRAVED NAMEPLATE ON THE WALL ABOVE THE SINGLE RECEPTACLE IN THE REAR AREA FOR HANDHELD STEAMER IDENTIFYING IT AS SUCH. 21.FURNISH TWO (2) COPIES IES OF THE ELECTRIC RISER DIAGRAM AND PANEL DIRECTORY(IES) TO THE TENANT FOR REVIEW AND APPROVAL, OR SUBMIT A LETTER TO THE TENANT CONFIRMING THAT THE SYSTEM WAS INSTALLED AS PER PLANS AND SPECIFICATIONS. 22.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 23.FURNISH AND INSTALL PANEL LOCKS WHERE SHOWN ON THE DRAWINGS. 24.WIRE EMERGENCY BALLAST AND BATTERY UGHTS ON SAME CIRCUIT IN AREA AND AHEAD OF LOCAL SWITCHING. 25.EXTERIOR SIGNAGE WILL BE FURNISHED AND INSTALLED BY SIGN CONTRACTOR. CONNECT TO SIGNS AND PROVIDE POWER AS REQUIRED FOR A COMPLETE INSTALLATION. COORDINATE THIS PORTION OF THE WORK WITH THE SIGN CONTRACTOR AND LANDLORD AS REQUIRED. 26.SOME LIGHTING FIXTURES WILL BE FURNISHED BY THE OWNER. PROCURE UGHTING FIXTURES FROM OWNER AND INSTALL THEM IN THE LOCATIONS SHOWN AS REQUIRED. CONTACT THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING A PROPOSAL TO DETERMINE WHICH FIXTURES (IF ANY) ARE NOT FURNISHED BY THE OWNER. INSTALL ALL FIXTURES (OWNER FURNISHED AND CONTRACTOR FURNISHED) AS REQUIRED FOR A COMPLETE INSTALLATION. LEAVE PROTECTIVE COVERING /FILM IN PLACE ON FIXTURES UNTIL FINAL CLEAN -UP. INSTALL UGHTING FIXTURES IN RATED CEILING SO AS TO MAINTAIN INTEGRITY OF RATING. REPLACE ANY LAMPS THAT HAVE EXPIRED DURING CONSTRUCTION AND MAKE ALL ADJUSTMENTS TO FIXTURES FOR DIRECTION AS REQUIRED PRIOR TO COMPLETION. 27.SWITCHES, NOT OTHERWISE CALLED OUT, SHALL BE MOUNTED 4'_6" ABOVE FLOOR. 28.RECEPTACLES AND TELEPHONE OUTLETS IN SALES AREA SHALL BE MOUNTED AT 18" A.F.F. UNLESS NOTED. RECEPTACLES AND COVERS SHALL BE AS CALLED FOR IN THE SPECIFICATIONS. 29.ALL COVERPLATES FOR ALL DEVICES SHALL BE AS REQUIRED TO MATCH ADJACENT FINISHES - COORDINATE WITH ARCHITECT. 30.VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES AND FLANGES AS REQUIRED. 31.IG AND GFI RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WIRE, THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPUCED BETWEEN THE DEVICE AND THE PANEL GROUND BUS. 32.MOUNTING HEIGHTS OF EQUIPMENT NOT SPECIFICALLY CALLED FOR ARE NOTED ON ARCHITECTURAL DRAWINGS - SEE ARCHITECTURAL DRAWINGS TO COORDINATE. 33.SUPPORT ALL FIXTURES ACROSS CEILING TEES OR FROM STRUCTURE ABOVE. IN NO CASE SHALL CEILING TILES OR PLASTER CEILING SUPPORT ANY FIXTURES. , 34.SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. AND SYMBOLS LIST, FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS. 35.THE OWNER WILL FURNISH AND INSTALL A COMPUTER SYSTEM (CASH REGISTERS AND COMPUTERS) FOR THE SPACE. CONTRACTOR SHALL FURNISH AND INSTALL CONDUITS WITH CATEGORY 5 CABLING FROM ONE LOCATION TO ANOTHER (VARIOUS PLACES) IN ALL LOCATIONS SHOWN ON THE DRAWINGS - EITHER IN PLAN OR IN THE SCHEMATIC WIRING DIAGRAM DETAIL CATEGORY 5 CABLING PROVIDED SHALL BE PROVIDED WITHOUT CONNECTORS ON THE ENDS AND WITH 10' -0" SLACK WHIPS AT EACH END FOR OWNER'S USE (VENDOR WILL ULTIMATELY MAKE CONNECTIONS). IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE - CABLEING RUN THROUGHOUT STORE IN THE PLENUM AREA SHALL BE SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE. 36.THE OWNER WILL FURNISH AND INSTALL A TRAFFIC COUNTER SYSTEM (SHOPPERTRAK - ORBIT SYSTEM) FOR THE SPACE. CONTRACTOR SHALL FURNISH AND INSTALL CONDUITS WITH CATEGORY 5 CABLING FROM ONE LOCATION TO ANOTHER (VARIOUS PLACES) IN ALL LOCATIONS SHOWN ON THE DRAWINGS - EITHER IN PLAN OR IN THE SCHEMATIC WIRING DIAGRAM DETAIL CABLE SHALL INSTALLED WITH 15' -0" TO 20' -0" SLACK AT EACH END. CATEGORY 5 CABLEING SHALL BE AS FOLLOWS: 4 PAIRS, 24 AWG, SOLID CONDUCTORS, TWISTED PAIRS, 7 X 32 TINNED COPPER, 12.5 Pf, 110 OHMS, CL2 PLENUM RATED - BERK -TEK CABLE #230247 (SOLID PLENUM) OR BELDEN CABLE #1701A (BONDED, SOLID TWISTED PAIRS, PLENUM) OR EQUAL. IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE - CABLEING RUN THROUGHOUT STORE IN THE PLENUM AREA SHALL BE AS MENTIONED BEFORE AND SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE. 37.GENERAL PURPOSE RECEPTACLES SHALL BE MOUNTED 18" ABOVE FINISHED FLOOR AS REQUIRED WITH THE ELECTRICAL FEEDS TO EACH RECEPTACLE INSTALLED DOWN IN THE WALL. SEE ARCHITECTURAL DRAWINGS FOR ALL HEIGHTS, DIMENSIONS AND CONFIGURATIONS OF DEVICES NOT INDICATED ON THESE DRAWINGS. REFERENCE SAME DRAWINGS FOR EQUIPMENT NOT IDENTIFIED. 38.VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES AND FLANGES AS REQUIRED. 39.SUPPORT ALL FIXTURES WITH UNISTRUT AS REQUIRED. 40. NOT USED. 41.WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, AND ONE YEAR GUARANTEE, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 42. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 43.PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 44.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL 45.ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. 46.UPON COMPLETION OF WORK, PREPARE LIGHTING AND POWER PROJECT RECORD AS- BUILTS. PRESENT THE COMPLETED DRAWINGS TO THE OWNER. AS -BUILT DRAWINGS SHALL INCLUDE ALL BRANCH CIRCUIT WORK, ANY PANELBOARD INFORMATION, FINAL SWITCHING, ETC. 47.ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE PROOFED TO THE SAME OR GREATER RATING THAN THAT OF THE ASSEMBLY. WHERE CONFLICT OCCURS, NOTIFY THE ARCHITECT. 48.ALL FUSES 600 AMPERES OR LESS SHALL BE UL LISTED, CLASS RK1 OR J, LOW -PEAK, DUAL ELEMENT, TIME DELAY, 600 VOLT. ACCEPTABLE MANUFACTURES ARE BUSSMAN, GOULD OR SHAWMUT. 49.VERIFY LOCAL CONDITIONS AT SITE. 50.COMPLY WITH ALL APPUCABLE CODES. 51.SECURE AND PAY FOR ALL REQUIRED PERMITS 52.THE TENANT MAY HIRE AN INDEPENDENT CONTRACTOR /INSPECTOR TO VERIFY THE PROPER INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM AS PER PLANS AND SPECIFICATIONS. SHOULD THERE BE ANY DISCREPANCIES IN THE INSTALLATION, THE CONTRACTOR WILL BE NOTIFIED IN WRITING AND HAVE TEN (10) WORKING DAYS TO RECTIFY THE ERRORS. IF THE TENANT DECIDES IT IS NECESSARY TO VERIFY THAT THE DEFICIENCIES HAVE BEEN CORRECTED BY MEANS OF A REINSPECTION, THE COST OF A REINSPECTION (PLUS 10 %) WILL BE DEDUCTED FROM THE FINAL CONTRACT INVOICE. EL09-- 07 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC DEC 2 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1,12009 PERMIT CENTER DATE: 11/1$/09 JOB NO: 09 - 066 DRAWN: STAFF CHECKED: DP W0- IL cc cc Q W can 00 Oz O Cn W 03 O cc °) d- W Q I- F Z� Q (NW 0 2 CC c^ I O 8 Q cti ��O =�a V,fI- Co I jig') L CD 4-0 L V STORE NUMBER %TBD REVISIONS 'A'- ISSUE LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 'I�' ISSUE DATE 'C' -ISSUE DATE SHEET TITLE ELECTRICAL SPECIFICATIONS SCALE 1/4' =1' - 0' SHEET NUMBER E5.0 U) - 0 C co :CI U) 0