HomeMy WebLinkAboutPermit EL09-0794 - CARTERS RETAILCARTERS RETAIL
17250 SOUTHCENTER PY
SUITE 144
ELO9-0794
City .f Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 -431 -2451
Web site: http://www.citukwila.waus
Parcel No.: 7888920020
Address: 17250 SOUTHCENTER PY TUKW
Suite No:
ELECTRICAL PERMIT
Permit Number: EL09 -0794
Issue Date: 12/31/2009
Permit Expires On: 06/29/2010
Tenant:
Name: CARTERS RETAIL
Address: 17250 SOUTHCENTER PY, STE 144 , TUKWILA WA
Owner:
Name: WIG PROPERTIES LLC -SS Phone:
Address: 4811 134TH PL SE , BELLEVUE WA
Contact Person:
Name: CLAUDINE SIEDLER Phone: 425 641 -2044
Address: 4811 134 PL SE , BELLEVUE WA
Contractor:
Name: NORTH PACIFIC ELECTRIC INC Phone: 360- 943 -6020
Address: 5746 BOSTON HARBOR RD , OLYMPIA WA
Contractor License No: NORTHPE957JA Expiration Date: 04/01/2011
DESCRIPTION OF WORK:
ELECTRICAL FOR TI INCLUDING THERMOSTAT WIRING
Value of Electrical: NRES: $30,000.00
RES: $0.00
Type of Fire Protection: SPRINKLERS /AFA
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Fees Collected: $725.00
National Electrical Code Edition: 2008
Date: 0-'3 —0
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this per does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perfo r ance of v y 6 z > k . 1 ary authorized to sign and obtain this electrical permit.
Signature:
Print Name:
Date: 3( ,Ro
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL09 -0794 Printed: 12 -31 -2009
Parcel No.: 7888920020
Address:
Suite No:
Tenant:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
17250 SOUTHCENTER PY TUKW
CARTERS RETAIL
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
EL09 -0794
ISSUED
12/11/2009
12/31/2009
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating constructiop or the performance of work.
Signature:
Print Name:
Use / + i et_D
Date:
3( fee- °Zoo,
doc: Cond -Elec
EL09 -0794 Printed: 12 -31 -2009
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htt ://www.ci.tukwita.wa.us
Electrical Permit No. i0'\ —O TIt
Project No.
For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: 788892- 0020 -07
Site Address: 17250 Sputhcenter Pkwy, Tukwila, WA 98188 Suite Number: 144 Floor: 1
Tenant Name: Carter's Retail Inc.
Property Owners Name: Wig Properties LLC - SS
Mailing Address: 4811 134th Place SE
New Tenant: ❑ Yes ❑ .. No
Bellevue
WA 98006
City
State
Zip
CONTACT PERSON Who do we contact when your permit is ready to be issued
Name: Claudine Siedler
Mailing Address:
E -Mail Address:
4811 134th Place SE
Day Telephone: (425) 641 -2044
Bellevue WA 98006
csiedler @wigproperties.com
City
Fax Number:
State
(425) 865 -8648
Zip
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
TBD
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
Valuation of Project (contractor's bid price): $_540)C00
Scope of Work (please provide detailed information): W to
Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No
Type of Use:
Type of work:
❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant improvement
❑ Low Voltage 0 Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served by:
gj Puget Sound Energy
❑ Seattle City Light
Hc\ApplicationsTorms- Applications On Line \l -2009 - Electrical Permit ApplicationAoc
bh
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $145.60
(including an attached garage)
❑ Garages, pools, spas and outbuildings $78.00 ea
❑ Low voltage systems
(alarm, furnace thermostat) $57.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $78.00
(no added/altered circuits)
❑ Service change with added /altered circuits $78.00
number of added circuits $11.00 ea
❑ Circuits added/altered without service change $52.00
(up to 5 circuits)
❑ Circuits added/altered without service change $52.00
(6 or more circuits) $7.30 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $57.00
(alarm, fumace thermostat)
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $60.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals
$75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Date:
Print Name: Manmohan K. Wig Day Telephone: (425) 747 -8540
Mailing Address: 4811 134th Place SE Bellevue WA 98006
City
Date Application Accepted:
Date Application Expires:
H:AApplicalions \Forms - Applications On Line AI -2009 - Electrical Permit Application.doe
bh
State
Zip
Staff Initials:
i
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 7888920020
Address: 17250 SOUTHCENTER PY TUKW
Suite No:
Applicant: CARTERS RETAIL
RECEIPT
Permit Number: EL09 -0794
Status: APPROVED
Applied Date: 12/11/2009
Issue Date:
Receipt No.: R09 -02057 Payment Amount: $580.00
Initials: WER Payment Date: 12/29/2009 10:54 AM
User ID: 1655 Balance: $0.00
Payee: WIG PROPERTIES
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 3785 580.00
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.00 580.00
Total: $580.00
PAYMENT
RECEIVED
doc: Receipt -06
Printed: 12 -29 -2009
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 7888920020 Permit Number: EL09 -0794
Address: 17250 SOUTHCENTER PY TUKW Status: PENDING
Suite No: Applied Date: 12/11/2009
Applicant: CARTER'S RETAIL Issue Date:
Receipt No.: R09 -01985
Initials:
User ID:
Payee:
JEM
1165
Payment Amount: $145.00
Payment Date: 12/11/2009 12:58 PM
Balance: $580.00
WIG PROPERTIES LLC -SS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 3773 145.00
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
000.345.832.00.00 145.00
Total: $145.00
PAYMENT
RECEIVED
doc: Receiot -06
Printed: 12 -11 -2009
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
E °r/PE MIT N
CITY OF TUKWILA BUILDING DIVISION 'a`
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:_,
(:(0...41
Type of Inspection:
Oa
Address:
Date Called:
Special Instructions:
Date Wanted:
0'�
a.m.
Requester:
Phone No:
Approved per applicable codes. ❑ Corrections required prior to approval.
OM M ENTS:
Cigkdon045 tot
/
i� (4
� 02/0\e/1 Date: 0
�,l 1 �rji,1VA1
ri $60.00 REINSPECTION FEE RE LURED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Inspector:
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
(Of o77
T NO.
2--
(206)431 -3670
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Project:
emo.•
keriki�
Type of Inspection:
; f
RECtP sor
Address:
Date Called:
Special Instructions:
Date Wanted:
�j
aim.
C.
Requester:
Phone No:
ElApproved per applicable codes. 53 Corrections required prior to approval.
COMMENTS:
—
kw o4C POE( 4-ad w4ioit l-
- gia-Aik-pslicocwi 41TI foof1bf L r&
- la 5/uc. r 5E4L o o'4 RAF
RECtP sor
- Be-elvta1R NJIOrt && W/' kf &b/w rd. roe_
V4C P 5d out
- 'J'i'e &a 5 i,J 44€L_
to CK Tzs oCC.07
r ric, frio4 og l o
Inspector:
jr
6/
Date: 02,1011/0
$60.00 REINSISECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPEt TION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
INSPECTION RECORD
Retain a copy with permit
P MIT NO.
Project: eiw.r. 15 Witif L
Type of Inspection:
703
Address:
fl l Sc, .5.c.. .5.c.. P
Date Called:
Special Instructions:
Date Wanted:
7/°1-.
a.m.
Requester:
Phone No:
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
COLrniti Cosiec
401/61 14 psi Co+jPuer6
Inspector:
Date: ol/02. -l10
D $60.00 REINSPECTION FEE REO IRED. Prior to inspection, feel must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
3
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
6� -01fl
PE IT NO.
CITY OF TUKWILA BUILDING DIVISION AZ
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: I I 5 KCTAIL/
��_{w
Type of Inspection:
7„,„
V
Address.
/77-So45.c*Pi.
Date Called:
Special Instructions:
Date Wanted:
2;
i /7
m:
Requester:
Phone No:
f
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:
af-wec‘
ri $60.00 REINSP CTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date: 01/27 to
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
6o-o71
E
r MIT N . •
(206)431 -3670
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Project: } _ ii"" "
Type of Inspection:
7003
Addre . 72o -5.C--
Date Called:
Special Instructions:
Date Wanted:
/
/
Cu
p.m.
Requester:
Phone No:
DApproved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
Date: 0' ' o
ri $60.00 REINS CTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Inspector:
Receipt No.:
Date:
•
r
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
PE MIT NO.
h
(206)431 -3670
Proje
rots kerm I.-
Type of Inspection:
Address:
172.5o5 .e.p,
Date Called:
Special Instructions:
Date Wanted:
a
glen.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval. ,
OMMENTS:
0. K -
Inspector:
Date:
of of r
r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
- A.._ .1 ..,. _ _- _ ........ _ ....:'7�...ca,.�w. tA!
Merchandise Display Allowance
Total Allowance
Space Type: Retail
Space Area (sf): 4000 sf
isp
Space Type:
aY Area (sf)M ='
FILE COPY
Space Calculation
Description Lamp Mark Fixture Wattage Fixture Quantity Total
4 Fl O 4 W T A 08 �4
� rescen t w i i rg, (2) W T- ABM 108 4
Fl uor
Oa t `153Q =Lighthig:Pawer HA) lowaflce Qptioi
2006 Washinton State Energy Code Compliance Form
Allowed Wattage per Table 15 -1: 1.5 W /sf
Space Allowed Wattage: 6000 W
Total =
Allowance Wattage per Table 15 -1 footnote 10:
Mtr'chanilsi? Pisplay ?tlipwance Wattage:
1.5
7874 W
Space Allowed Wattage:
chandlse:Display Allowance Wattage:
Total Allowance:
6000 W
968 W
W
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
DEC 2 2 2009
City of Tukwila
BUILDING DIVISION
CITY OF n VED
DEC 11 2009
PERMIT CENTER
1 — 01 cH
2006 Washington State Nonresidential Energy Code Compliance Form
Project Summary
PRJ -SUM
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Project Address
Southcenter Square
Date 12/16/2009
17250 Southcenter Parkway,
Space
144
(Carters)
For Building Department Use
Tukwila, WA 98188
Applicant Name:
carters
ApplicantAddress:
Southcenter Square, space
144
Applicant Phone:
unknown
FILE COPY
ELO'J' cfAl
REVIEWED P
COMPLIANCE WITH
NFPA 70 - NEC
DEC 2 2 2009
City of Tukwila
BUILDING DIVISION
RECEIVED
DEC 112009
PERMIT CENTEF
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary
2006 Washington State Nonresidential Energy Code Compliance Forms
LTG -INT
Project Info
Project Address
Southcenter Square
Date
Revised July 2007
12/16/2009
17250 Southcenter Parkway, Space 144 (Carters)
Tukwila, WA 98188
Applicant Name: Carters
Applicant AddreSS: Southcenter Square, space 144
Applicant Phone:
unknown
For Building Department Use
Project Description
Compliance Option
[11 New Building ❑ Addition Q Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans
Alteration Exceptions
(check appropriate box - sec. 1132.3)
❑ No changes are being made to the lighting
❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2 ""
Area in ft2
Allowed x Area
Sales
retail sales
1.50
4000.0
6000.0
Sales
display allowance
1.50
1312.0
1968.0
Sales
Al - 2 x 4 Fluorescent
3
64.0
192.0
-1 (over) - document all exceptions on form LTG-
Proposed Lighting Wattage
Total Allowed Watts
7968.0
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Sales
A - 2 x 4 Fluorescent
44
108.0
4752.0
Sales
A /EM - 2 x 4 Fluorescent with emergency
6
108.0
648.0
Sales
Al - 2 x 4 Fluorescent
3
64.0
192.0
Sales
Al - 2 x 4 Fluorescent with emergency
1
64.0
64.0
Sales
B - Semi Recessed Metal Halide Wall Washer
21
70.0
1470.0
Sales
81 - Track mounted Metal Halide Wall Washer
4
75.0
300.0
Sales
F - 4 foot strip fluorescent
7
64.0
448.0
o l Proposed Watts may not exceed Total Allowed Watts for Interior
Total Proposed Watts
7874.0
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual
may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable,
the wattage of current limiting devices or of the transformer.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank.
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary (back)
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Prescriptive Spaces
Occupancy:
0 Warehouses, storage areas or aircraft storage hangers 0 Other
Qualification Checklist
answer If is occupancy
ked type is "Other" and fixture
answer is checked, the number of fixtures in
in
the space is not limited by Code. Clearly
indicate these spaces on plans. If not
qualified, do LPA Calculations.
Lighting
Fixtures:
(Section
(
1521)
❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted.
1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector
or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec-
tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify.
2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts
3. LED lights.
-"1 Unit LIgntin g rower Allowance
Use'
LPA2 (W /sfLUse'
LPA` (W /sf)
Automotive facility
0.9
Office buildings, office /administrative areas in
facilities of other use types (including but not limited
to schools, hospitals, institutions, museums, banks,
churches)'.' 11
1.0
Convention center
1.2
Penitentiary and other Group 1 -3 Occupancies
1.0
Courthouse
1.2
Police and fire stations°
1.0
Cafeterias, fast food establishments',
restaurants /bars°
1.3
Post office
1.1
Dormitory
1.0
Retail10, retail banking, mall concourses, wholesale
stores (pallet rack shelving)
1.5
Exercise center
1.0
School buildings (Group E Occupancy only), school
classrooms, day care centers
1.2
Gymnasia °, assembly spaces°
1.0
Theater, motion picture
1.2
Health care clinic
1.0
Theater, performing arts
1.6
Hospital, nursing homes, and other Group 1 -1 and
1 -2 Occupancies
1.2
Transportation
1.0
Hotel /motel
1.0
Warehouses'', storage areas
0.5
Hotel banquet/conference /exhibition hall'"
2.0
Workshops
1.4
Laboratory spaces (all spaces not classified
"laboratory" shall meet office and other appropriate
categories)
1.8
Parking garages
0.2
Laundries
1.2
Libraries'
1.3
Plans Submitted for Common Areas Only'
Manufacturing facility
1.3
Main floor building lobbies° (except mall concourses)
1.2
Museum
1.1
Common areas, corridors, toilet facilities and
washrooms, elevator lobbies
0.8
Footnotes for Table 15 -1
1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned
specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most
comparable use specified in the table. See Section 1512 for exempt areas.
2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed
otherwise by subsequent footnotes.
3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6) Reserved.
7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used.
8) Reserved.
9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is
2.60 W /ft2.
10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves
with the display are exempt.
An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following:
a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points
of track attachment).
c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for
computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only)
of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks.
2006 Washington State Nonresidential Energy Code Compliance Form
Lighting Power Allowance Adjustments
LTG -LPA
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Address
Southcenter Square
Date
12/16/2009
Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The
Occupancy Description should agree with the Use listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet,
12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts
per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM.
Adjusted Lighting Power Allowances (Interior)
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2 **
Ceiling Height
for this room
Ceiling Height limit
for this exception **
Adjusted LPA
Watts per ft2
Sales
retail sales - display credit
1.50
10.0 feet
12 feet
1.50
** From Table 15 -1 based on exceptions listed in footnotes
2006 Washington State Nonresidential Energy Code Compliance Form
Lighting,
2006 Washington State
Motor, and Transformer Permit Plans Checklist LTG -CHK
Nonresidential Energy Code Compliance Forms Revised July 2007
Project Address southcenter square
'Date 12/16/2009
The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements
in the 2006 Washington State Nonresidential Ene gy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section 1513)
yes
1513.1
Local control /access
Schedule with type, indicate locations
yes
1513.2
Area controls
Maximum limit per switch
yes
1513.3
Daylight zone control
Schedule with type and features, indicate locations
n.a.
vertical glazing
Indicate vertical glazing on plans
n.a.
overhead glazing
Indicate overhead glazing on plans
n.a.
1513.4
Display /exhib /special
Indicate separate controls
1513.5
Exterior shut -off
Schedule with type and features, indicate location
n . a .
(a) timer w /backup
Indicate location
n.a.
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off
Indicate location
yes
1513.6.1
(a) occup. sensors
Schedule with type and locations
yes
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability);
Indicate size of zone on plans
n . a .
1513.7
Commissioning
Indicate requirements for lighting controls commissioning
EXIT SIGNS (Section 1514)
yes
1514
Max. watts
Indicate watts for each exit sign
I
1
LIGHTING POWER ALLOWANCE (Section 1530- 1532)
yes
1531
Interior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
n.a.
1532
Exterior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
MOTORS (Section 1511)
1 no I
1511
Elec motor efficiency jMECH
-MOT or Equipment Schedule with hp, rpm, efficiency
TRANSFORMERS (Section 1540)
n.a. I
1540 (Transformers
'Indicate
size and efficiency 1
If "no" is circled for any question, provide explanation:
2006 Washington State Nonresidential Ener Code Compliance Form
Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Lighting - General Requirements
1513 Lighting Controls: Lighting, including exempt lighting
in Section 1512, shall comply with this section. Where
occupancy sensors are cited, they shall have the features
listed in Section 1513.6.1. Where automatic time switches
are cited, they shall have the features listed in Section
1513.6.2.
1513.1 Local Control and Accessibility: Each space,
enclosed by walls or ceiling- height partitions, shall be
provided with lighting controls located within that space. The
lighting controls, whether one or more, shall be capable of
turning off all lights within the space. The controls shall be
readily accessible, at the point of entry/exit, to personnel
occupying or using the space.
EXCEPTIONS: The following lighting controls may be
centralized in remote locations:
1. Lighting controls for spaces which must be used as
a whole.
2. Automatic controls.
3. Controls requiring trained operators.
4. Controls for safety hazards and security.
1513.2 Area Controls: The maximum lighting power that
may be controlled from a single switch or automatic control
shall not exceed that which is provided by a 20 ampere circuit
loaded to not more than 80 %. A master control may be
installed provided the individual switches retain their capability
to function independently. Circuit breakers may not be used
as the sole means of switching.
EXCEPTIONS: 1. Industrial or manufacturing process
areas, as may be required for production.
2. Areas less than 5% of the building footprint for
footprints over 100,000 ft2.
1513.3 Daylight Zone Control: All daylighted zones, as
defined in Chapter 2, both under overhead glazing and
adjacent to vertical glazing, shall be provided with individual
controls, or daylight- or occupant- sensing automatic controls,
which control the lights independent of general area lighting.
Contiguous daylight zones adjacent to vertical glazing are
allowed to be controlled by a single controlling device
provided that they do not include zones facing more than two
adjacent cardinal orientations (i.e. north, east, south, west).
Daylight zones under overhead glazing more than 15 feet
from the perimeter shall be controlled separately from daylight
zones adjacent to vertical glazing.
EXCEPTION: Daylight spaces enclosed by walls or
ceiling height partitions and containing 2 or fewer light
fixtures are not required to have a separate switch for
general area lighting.
1513.4 Display, Exhibition and Specialty Lighting
Controls: All display, exhibition or specialty lighting shall be
controlled independently of general area lighting.
1513.5 Automatic Shut -off Controls, Exterior: Lighting for
all exterior applications shall have automatic controls capable
of turning off exterior lighting when sufficient daylight is
available or when the lighting is not required during nighttime
hours. Lighting not designated for dusk -to -dawn operation
shall be controlled by either:
a. A combination of a photosensor and a time switch;
or
b. An astronomical time switch.
Lighting designated for dusk -to -dawn operation shall be
controlled by an astronomical time switch or photosensor. All
time switches shall be capable of retaining programming and
the time setting during loss of power for a period of at least 10
hours.
EXCEPTION: Lighting for covered vehicle entrances
or exits from buildings or parking structures where
required for safety, security, or eye adaptation.
1513.6 Automatic Shut -Off Controls, Interior: Buildings
greater than 5,000 ft2 and all school classrooms shall be
equipped with separate automatic controls to shut off the
lighting during unoccupied hours. Within these buildings, all
office areas Tess than 300 ft2 enclosed by walls or ceiling -
height partitions, and all meeting and conference rooms, and
all school classrooms, shall be equipped with occupancy
sensors that comply with Section 1513.6.1. For other spaces,
automatic controls may be an occupancy sensor, time switch
or other device capable of automatically shutting off lighting.
EXCEPTIONS: 1. Areas that must be continuously
illuminated (e.g., 24 -hour convenience stores), or
illuminated in a manner requiring manual operation of
the lighting.
2. Emergency lighting systems.
3. Switching for industrial or manufacturing process
facilities as may be required for production.
4. Hospitals and laboratory spaces.
5. Areas in which medical or dental tasks are
performed are exempt from the occupancy sensor
requirement.
1513.6.1 Occupancy Sensors: Occupancy sensors shall
be capable of automatically turning off all the lights in an
area, no more than 30 minutes after the area has been
vacated.
Light fixtures controlled by occupancy sensors shall have a
wall- mounted, manual switch capable of turning off lights
when the space is occupied.
EXCEPTION: Occupancy sensors in stairwells are
allowed to have two step lighting (high -light and low -
light) provided the control fails in the high -light position.
1513.6.2 Automatic Time Switches: Automatic time
switches shall have a minimum 7 day clock and be capable
of being set for 7 different day types per week and
incorporate an automatic holiday "shut -off' feature, which
turns off all loads for at least 24 hours and then resumes
normally scheduled operations. Automatic time switches
shall also have program back -up capabilities, which prevent
the loss of program and time settings for at least 10 hours, if
power is interrupted.
Automatic time switches shall incorporate an over -ride
switching device which:
a. is readily accessible;
b. is located so that a person using the device can see the
lights or the areas controlled by the switch, or so that the
area being illuminated is annunciated;
c. is manually operated;
d. allows the lighting to remain on for no more than 2 hours
when an over -ride is initiated; and
e. controls an area not exceeding 5,000 ft2 or 5% of the
building footprint for footprints over 100,000 ft2, whichever is
greater.
1513.7 Commissioning Requirements: For lighting
controls which include daylight or occupant sensing
automatic controls, automatic shut -off controls, occupancy
sensors, or automatic time switches, the lighting controls
shall be tested to ensure that control devices, components,
equipment and systems are calibrated, adjusted and operate
in accordance with approved plans and specifications.
Sequences of operation shall be functionally tested to
ensure they operate in accordance with approved plans and
specifications. A complete report of test procedures and
results shall be prepared and filed with the owner. Drawing
notes shall require commissioning in accordance with this
paragraph.
1514 Exit Signs: Exit signs shall have an input power
demand of 5 Watts or less per sign.
Motors - General Requirements
1511 Electric Motors: All permanently wired polyphase
motors of 1 hp or more, which are not part of an HVAC
system, shall comply with Section 1437.
EXCEPTIONS: 1. Motors that are an integral part of
specialized process equipment.
2. Where the motor is integral to a listed piece of
equipment for which no complying motor has been
approved.
Transformers - General Requirements
SECTION 1540 — TRANSFORMERS
The minimum efficiency of a low voltage dry -type
distribution transformer shall be the Class I Efficiency Levels
for distribution transformers specified in Table 4 -2 of the
"Guide for Determining Energy Efficiency for Distribution
Transformers" published by the National Electrical
Manufacturers Association (NEMA TP -1- 2002).
3ERIWIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL09 -0794
PROJECT NAME: CARTER'S RETAIL INC.
DATE: 12 -11 -09
SITE ADDRESS: 17250 SOUTHCENTER PY, STE 144
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS:
�uiTding Division �■,`v�
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 12-15-09
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
REVIEWER'S INITIALS:
DUE DATE: 01-12-10
Approved with Conditions tifr Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Untitled Page
Page 1 of 2
Electrical Contractor
A business licensed by LEtI to contract electrical work within the scope of its specialty.
Electrical Contractors must maintain a surety bond or assignment of savings account.
They also must have a designated Electrical Administrator or Master Electrician who is a
member of the firm or a full -time supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
NORTH PACIFIC ELECTRIC
INC
3609436020
5746 BOSTON HARBOR RD
OLYMPIA
WA
98506
THURSTON
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration
Date
Suspend Date
Specialty 1
Specialty 2
602117535
ACTIVE
NORTHPE957JA
ELECTRICAL
CONTRACTOR
4/1/2005
4/1/2011
GENERAL
UNUSED
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
NORTHPE159RU
NORTH
PACIFIC
ELECTRIC
INC
ELECTRICAL
CONTRACTOR
GENERAL
UNUSED
12/31/1985
3/31/2001
ARCHIVED
NORTHPE277B3
NORTH
PACIFIC
ELECTRICAL
INC
ELECTRICAL
CONTRACTOR
GENERAL
UNUSED
1/23/1973
12/31/1986ARCHIVED
NORTHPE994JB
NORTH
PACIFIC
ELECTRIC
ELECTRICAL
CONTRACTOR
GENERAL
UNUSED
4/3/2001
4/3/2005
EXPIRED
MASTER ELECTRICIAN INFORMATION
License KULLMBM974BU
Name KULLMANN, BERNHARD
https://fortress.wa.gov/Ini/bbip/Detail.aspx
12/31/2009
1-1 S O SIBH I SCHEDULE NOTES: a:) THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE FOR ACCURACY PRIOR TO BEGINNING
CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO TENANT CONSTRUCTION PROJECT MANAGER.
DESCRIPTION
G.G.
GARTERS
LANDLORD
DESCRIPTION
G.G.
GARTERS
LANDLORD
N/A
DIVISION 01000 - GENERAL
SUPPLY
INSTALL
SUPPLY
INSTALL
AS-IS
BY LL
REMARKS
SUPPLY INSTALL
SUPPLY INSTALL
BY LL
REMARKS
LANDLORD BUILDING PERMIT SUBMITTAL
•
DIVISION 15000 - MECHANICAL
LANDLORD BUILDING PLAN GHEGK FEES
•
HVAG EQUIPMENT "ROOF TOP"
•
LANDLORD BUILDING PERMIT FEES
• •
•
ROOF WORK AND EQUIPMENT CURBS
0 000
TENANT BUILDING PERMIT SUBMITTAL
BY TENANTS PERMIT VENDOR
HVAG DISTRIBUTION, DUCTWORK
TENANT BUILDING PLAN CHECK FEES
G.G. SHALL PICK UP PERMIT AND PERMIT FEES
DIFFUSERS
TENANT BUILDING PERMIT FEES
0
BUILDING PERMIT FEES
EXHAUST FANS AND VENTING
DEMOLITION
N/A
STOCKROOM UNIT HEATER
•
LANDLORD GLEAN -UP #I AT TURN -OVER
0
SMOKE DETECTORS
•
TENANT G.G. FINAL GLEAN -UP #I AT TURN -OVER
0
0
FIRE SPRINKLER MAIN
0
EXISTING
TENANT G.G. FINAL GLEAN -UP #2 AT PRE- OPENING
0
COORDINATE WITH STORE MANAGER
SPRINKLER SYSTEM
0
EXISTING
NEUTRAL PIERS AND MALL BULKHEAD
EXISTING
SPRINKLER SYSTEM MODIFICATIONS
•
OTHER PERMITS, FEES, INSURANCE
0
0
PLUMBING FIXTURES (TOILET ROOMS)
TEMPORARY POWER
•
0
IF REQUIRED
DRINKING FOUNTAIN
N/A
TEMPORARY BARRICADES
•
0
FOR STOREFRONT WORK
WATER AND SEWER STUB
•
TEMPORARY BARRICADE GRAPHICS
•
SANITARY PIPING
TRASH REMOVAL/DISPOSAL AND DUMPSTERS
0
0
DOMESTIC WATER PIPING
•
DUMPSTER AT TURNOVER
•
•
G.G. TO EMPTY, DUMPSTER PRIOR TO MERCHANDISE ARRIVAL
ACCESS PANELS
•
FINAL INSPECTIONS AND CERTIFICATE OF OGGUPANGY
•
COORDINATED WITH TENANTS ARCH IGTEGT
WATER HEATER
MOP SINK, MOP HANGER AND HOSE
DIVISION 1 6000 - ELECTRICAL
DIVISION 03000 - CONCRETE WORK
ELECTRICAL SERVICE CONDUIT TO TENANT SPACE
•
NEW SERVICE SEE ELECTRICAL DRAWINGS.
CONCRETE TRENCH FOR NEW PLUMBING
•
•
ELECTRICAL SERVICE
NEW SERVICE SEE ELECTRICAL DRAWINGS.
CONCRETE TRENCH FOR GASHDESK POWER
0
•
ELECTRICAL PANELS
0
NEW BY LANDLORD
CONCRETE POUR BACK FOR LEAVE OUT
•
•
TRANSFORMER
•
NEW BY LANDLORD
FIRE ALARM SYSTEM
DIVISION 05000 - METALS
EMERGENCY LIGHTING
0
SEE LIGHT FIXTURE SCHEDULE
DEMISING PARTITION FRAMING
•
•
EXIT SIGNS
0
SEE LIGHT FIXTURE SCHEDULE, RETAIL AREA TO BE CLG MOUNTED
DEMISING PARTITION FURRING
N/A
FLUORESCENT LIGHT FIXTURES
•
SEE LIGHT FIXTURE SCHEDULE
TOILET ROOM WALL FRAMING
0
FLUORESCENT LAMPS
0
SEE LIGHT FIXTURE SCHEDULE
STOCKROOM WALL FRAMING
•
ACCENT LIGHT FIXTURES
0
0
SEE LIGHT FIXTURE SCHEDULE
OFFICE WALL FRAMING
0
ACCENT LIGHT LAMPS
0
SEE LIGHT FIXTURE SCHEDULE
COLUMN ENCLOSURE FRAMING
•
THERMOSTATS
0
TENANT SPEC, LIGHTSTAT MODEL THE -POI
MASONRY WALL METAL FURRING
0
EXISTING
WIRING, CIRCUITING, RECEPTACLES, SWITCHES
0
ALL LANDLORD ITEMS SEE E -I AND E -2
WIRING, CIRCUITING, RECEPTACLES, SWITCHES
•
0
ALL TENANT ITEMS SEE E -I AND E -2
WIRING AND CONNECTION OF GASHWRAP
0
0
SEE ELECTRICAL DRAWING E -2
DIVISION 06000 - WOOD AND PLASTICS
TIME CLOCK, FOR STOREFRONT SIGN
ROUGH CARPENTRY, TENANT WORK,
0
0
ALL LOW VOLTAGE TELEPHONE AND DATA GAT -5 WIRING
•
•
G.G. TO CONTRACT WITH COMM WORKS FOR INSTALL
INTERIOR WOOD TRIM, TENANT WORK
SHOPPER TRACK (J -BOX 4 CONDUIT)
•
BLOCKING (FIRE RETARDANT LUMBER 4 PLYWD)
0
•
SHOPPER TRACK (CABLE)
0
0
G.G. TO CONTRACT WITH GOMM WORKS FOR INSTALL
TELEPHONE CONDUIT AND PULL STRING WIRING
0
EXISTING, G.G. TO RELOCATE IF REQUIRED
TELEPHONE SERVICE
0
0
G.G. TO COORDINATE WITH TENANT FOR PHONE SERVICE
TENANT VENDORS:
DIVISION 07000 - THERMAL 4 MOISTURE PROTECTION
FIBERGLASS BATT INSULATION
0
0
LIGHTING SPECIALTY STORE LIGHTING
35 INDUSTRIAL PARK RD.
CENTERBROOK, GT
Larry De Francesco
(860) 161- 0110x204
y FIXTURES LEIDEN CABINET COMPANY
2385 EDISON BOULEVARD
TWINSBURG, OH 44081
Mike Hopp
(330) 425 -8555
LOCKS / A -OK SECURITY
DOOR HOW. (817) 265 -2100
Garlgoa- oksecurity
AIR INFILTRATION BARRIER
•
EXISTING
SEALANT AND CAULKING
0
0
0
GENERAL WHERE REQUIRED BY NEW WORK
FIRE STOPPING
0
0
WHERE ANY NEW REQUIRED
ROOFING/FLASHING
WATERPROOF MEMBRANE "WET AREAS"
N/A
FLOORING SG5 FLOORING SYSTEM
530 S. MAIN ST. SUITE 110
ORANGE, GA 12868
BARRY SCHWARTZ
(714)) -2146
SIGNS IMAGE CONSULTING SERVICES
1 175 Donwell
5. Euclid, OH 44121.
Patrick O'Dea
(440) 15I-11 1/
LOW VOLTAGE GOMM - WORKS, LLG
CONTRACTOR 3550 ANNAPOLIS LAND N.
PLYMOUTH, MN 55447
Tel. 136 -852 -3100
DIVISION 08000 — DOORS 4 WINDOWS
STOREFRONT ENTRY DOORS
•
STOREFRONT ALUMINUM FRAMING AND GLASS
•
INTERIOR DOORS, FRAMES,
•
SEE DOOR SCHEDULE,
r 542
PROJECT DATA / DIRECTORY:
INTERIOR DOOR LEVER SETS
0
0
0
SEE DOOR SCHEDULE,
PROJECT NAME: CARTERS,
SPACE NO. 144
SQUARE
PKWY
WA 18188
CLOTHING STORE
APPAREL
SIEDLER
LLG
PLAGE SE
WA 18006
RETAIL
DRIVE
LAG, WI 54135
Schainske
Manager
332 -0420
PROJECT COORDINATOR: DON KAMM
T
REAR SERVICE DOOR, FRAME 4 HARDWARE
•
SEE DOOR SCHEDULE,
REAR SERVICE DOOR EXIT DEVICE SYSTEM
0
0
SEE DOOR SCHEDULE, " °»
AOUTHCENTER
17250 SOUTHCENTER
TUKWILA,
PROJECT DESCRIPTION: CHILDRENS
GADD TECH
225 Oakland Rd., Suite 105
South Windsor, GT 06074
Tel. (860) 783 -5670
TENANTS ARCHITECT: KENNETH L. BUTTS, ARCHITECT
A -OK SECURITY LOCKS AND GORES
o
SEE DOOR SCHEDULE
DIVISION 01000 - FINISHES
AND RELATED
TENANT COORDINATOR: CLAUDINE
CEILING SUSPENSION SYSTEMS
•
124 STAGE COACH ROAD
BELL CANYON, GA 11307
TEL: (818) 111 -4272
FAX: (818) -111 -4321
TENANTS ENGINEER: DONN PENN, CONSULTING ENGINEER
ACOUSTICAL TILES (SALES)
0
WIG PROPERTIES
4811 -134TH
BELLEVUE,
TENANT: CARTERS
ACOUSTICAL TILES (NON - SALES)
•
GYP. BD. CEILING (SALES)
N/A
GYPSUM WALL BOARD (DEMISING PARTITION)
0
0
BUILDING DEPT.:
655 WESTPORT PARKWAY, SUITE 500 GRAPEVINE, TEXAS 76051
Tel. 817 -410 -2858
DEPARTMENT OF COMMUNITY DEVELOPMEN
6300 SOUTHCENTER GLVD, #100
TUKWILA, WA 18188
ATT: BUILDING OFFICIAL
(206) 431 -3655
GYPSUM WALL BOARD (HG TOILET ROOM PARTITIONS)
•
GYPSUM WALL BOARD (STOCK ROOM PARTITION)
®
GYPSUM WALL BOARD (COLUMN ENCLOSURES)
0
W5167 KENNEDY
FOND DU
Ms. Brenda
Project
TEL: (120)
GYPSUM WALL BOARD (OFFICE /HALL)
0
GYPSUM WALL BOARD (MOP SINK AREA)
SALES AREA FLOORING
0
•
SHEET VINYL FLOORING (TOILET ROOM)
•
VGT (OFFICE /STOCK /HALL)
•
WALL BASE (SALES)
0
0
CODE SUMMARY
VINYL BASE (OFFICE /STOCK /HALL)
®
REDUCER STRIPS, ADHESIVE, ETC.
APPLICABLE CODES:
BUILDING CODE: 2006 International Building Code - Chapter 51 -50 WAG
M ECHANICAL CODE: 2 006 I nternational Mechanical Code (IMG 06) -Gha p
CODE: 2006` Uniform Plumbing Code (Chapters 51 -56 and 51
ELECTRICAL CODE: 2008 National Electrical Code (NFPA 10)
ENERGY CODE: 2006 Washington State Energy Code- Chapter 51 -11
ACCESSIBILITY: 2005 IGG /ANSI A111.1
CHAPTER 10 MEANS OF EGRESS
OCCUPANCY CALCULATIONS: TABLE 1004.1.1
ROOM OCCUPANT OCCUPANT 2 EXITS
ROOM DESCRIPTION AREA FACTOR LOAD REQUIRED
BUILDING DATA:
ter 51 -52 WA USE GROUP: (M) Mercanti
-57 WAG) CONSTRUCTION TYPE: I IB
GROSS FLOOR AREA: 4,000 S.F.
WAG OCCUPANCY LOAD: 112
SPRINKLER: Yes NFPA IE
FIRE ALARM: Yes NFPA 1
FIRE EXTINGUISHERS: Yes NFPA IC
MINIMUM PLUMBING FIXTURES (EXISTING)
2006 UNIFORM PLUMBING CODE, CHAPTER 4
412.5. Facilities in Mercantile and Business Occupancies Se
TABLE "A" OCCUPANT LOAD FACTOR
GROUP "M" 200 / 4000 S.F. = 20 PERSONS
10 MALE / 10 FEMALE
TABLE 4 -I RETAIL OR WHOLESALE STORES
WATER CLOSET: MALE I:1 -100 PROVIDED I
FEMALE I:I -25 PROVIDED I
LAVATORY: ONE FOR EVERY TWO WATER CLOSETS
PROVIDED MALE I
PROVIDED FEMALE : I
DRINKING FOUNTAINS: 0:1 -30 NOT REQUIRED
SERVICE SINK: NOT REQUIRED
PROVIDED:
FLOOR PREP, INCLUDING LEVELING
•
•
®
FLOOR PROTECTION
0
•
•
PAINTING, FINISHING SALES AREA
•
PAINTING, FINISHING NON -SALES AREA
0
CORNER GUARDS
0
SEE SHEET AI.2 FOR SPECIFICATION
DIVISION 10000 - SPECIALTIES
STOREFRONT ILLUMINATED SIGNS
•
TENANT SIGN CONTRACTOR
BLADE SIGN
•
•
TENANT SIGN CONTRACTOR
INTERIOR SIGNS LOGO SIGNS
•
•
INTERIOR GRAPHICS BY TENANT VENDOR
"COMING SOON" SIGN
0
0
INTERIOR GRAPHICS BY TENANT VENDOR
EMPLOYMENT "NOW HIRING" SIGNS D
0
TOILET ACCESSORIES (OTHER THAN NOTED BELOW)
•
TOILET ACCESSORIES : PAPER TOWEL HOLDER,
0
•
LANDLORD TO INSTALL
TOILET PAPER HOLDER, SOAP DISP. STORAGE CABINET
•
•
LANDLORD TO INSTALL
KOALA CHANGING STATION
0
0
TOILET ROOM UTILITY CABINET
0
LANDLORD TO INSTALL
H.G. GRAB BARS
•
ACCESSIBILITY SIGNAGE
0
•
WHERE REQUIRED
100 SALES AREA 3301 5.F. 30 110 YE5
101 HALLWAY 108 5.F. 0 0 NO
102 H.G. TOILET ROOM WOMENS 58 S.F. O 0 NO
103 H.G. TOILET ROOM MENS 64 S.F. 0 0 NO
104 OFFICE 13 S.F. 100 I NO
105 STOCK ROOM 316 S.F. 300 2 NO
FIRE EXTINGUISHERS
DIVISION 11000 - EQUIPMENT
SHOPPER TRACK
0
0
INSTALL BY TENANT VENDOR
SECURITY SYSTEM
0
0
0
G.G. TO COORDINATE WITH CHECKPOINT
POS EQUIPMENT "CASH RESISTERS"
0
0
0
INSTALL BY TENANT VENDOR COMM WORKS, CONTRACTED BY G.G.
COMPUTER SYSTEMS
0
0
0
INSTALL BY TENANT VENDOR GOMM WORKS, CONTRACTED BY G.G.
TOTAL: 4,000 S.F. 112 YES
REFRIGERATOR / MICROWAVE / LOCKERS / BREAK TABLE
0
•
SAFE
0
0
BOLT TO FLOOR WITH EXPANSION ANCHORS
EGRESS WIDTH PER OCCUPANT: TABLE
1 005.1 INCHES PER PERSON
= 17 INCHES (REQUIRED)
FRONT:
DOORS = 68" CLEAR
REAR:
= 34" CLEAR
=102" CLEAR
Exception #2 Not located less than
dimension of the area being served.
AUDIO EQUIPMENT AND SPEAKERS
0
0
INSTALL BY TENANT VENDOR
1.) EGRESS COMPONENTS (WITH SPRINKLERS)
0.15 INCHES PER OCCUPANT x 112 OCCUPANTS
2.) ACTUAL WIDTH PROVIDED THROUGH
THROUGH FRONT AREA (PAIR 3' -0:"
3J ACTUAL WIDTH PROVIDED THROUGH
THROUGH REAR (I) 3' -0" DOOR
TOTAL EGRESS WIDTH PROVIDED:
1015.2.1 TING EXIT ACCESS DOORWAYS:
one third of the overall diagonal
DIVISION 12000 - FURNISHINGS
GASHDESK
0
0
FLOOR FIXTURES
•
SURFACE MOUNT WALL STANDARDS
•
HARDWARE AND BRACKETS FOR STANDARDS
0
0
ROLLING SAFETY LADDER
•
•
HARDWARE STORAGE UNIT
•
•
OFFICE COUNTERS
•
•
toms kom
1016.1 MAXIMUM TRAVEL: 250 feet sprinklered
1011.1 MINIMUM NUMBER OF EXITS: I -500 Occupants / 2 Exits required
le
2
PROJECT
babies and kids
SOUTHCENTER SQUARE
17250 SOUTHCENTER PKWY
TUKWILA, WA AREA 4,000 SQ/FT
TENANT SPACE No. 144
PROJECT KEY PLAN
GARTERS
SOUTHCENTER SQUARE
TUKWILA, WA 1 1S 188
SPACE NO. 144
rving Customers
PROVIDED 2
soulrormem P,Au
.110 KOLIAMO
tb.LIZIEWILION
PETW. 'tnta f:tfoomfgat l�.J ti''tItui
.Roszontot stAtg-ittOWIlltbtirithe4 K' tY Mtn Sid
DRAWING INDEX
ARCHITECTURAL
G I . I TITLE, INDEX, KEY PLAN,
DATA
G I.2 DOOR SCHEDULE, DOOR
CONTRACTOR NOTES
FXLE C Y
Permit No. E 01
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Fi :j Copy < Coll � 'ons is acknowledged:
By
Date:
Soulhanter
r
City Of Tukwila
BUILDING DIVISION
No changes shall be made to the scope
Tukwila Building Division.
OTE. evisions will require a new plan submittal
z nil may include additional plan review fees.
RESPONSIBILITY SCHEDULE, PROJECT
TYPES AND DOOR HARDWARE, GENERAL
A0.1 LEASEOUTL I NE FLOOR AND STRUCTURE PLAN
AI.I CONSTRUCTION PLAN (LANDLORD WORK)
AI.2 FLOOR FINISH PLAN / FINISH SCHEDULE / ROOM FINISH SCHEDULE
Al.3 WALL STANDARDS INSTALLATION PLAN
A1.4 FLOOR FIXTURING / MILLWORK PLAN
A2.I REFLECTED CEILING PLAN
A3.I STOREFRONT ELEVATIONS, DETAILS, EXTERIOR SIGNS
A3.2 SALES AREA, ELEVATIONS, KEY PLAN
A5.5 TOILET ROOM, PART PLAN ELEVATIONS
A3.4 STOCKROOM OFFICE, PART PLAN, ELEVATIONS
A4.1 INTERIOR SECTIONS AND DETAILS
A4.2 INTERIOR SECTIONS AND DETAILS
A5.I STOCKROOM SHELVING a DETAILS
A6.I ROOF PLAN / HVAG UNIT INSTALLATION
M.E.P. ENGINEERING
El
E2
E3
E4
E5
MI
M2
PI
FLOOR PLAN LIGHTING WORK
FLOOR PLAN - MISC. ELECTRICAL WORK
ELECTRICAL DETAILS
LOW VOLTAGE DIAGRAMS
ELECTRICAL SPECIFICATIONS
FLOOR PLAN - MECHANICAL WORK
MECHANICAL SPECIFICATIONS
FLOOR PLAN - PLUMBING WORK
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 -NEC
DEC 22 2009
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKVOLA
DEC 1:.1 2009
PERMIT CENTER
°1-cri°H
DATE: 11/15/09
JOB NO: 09 -066
DRAWN: STAFF
CHECKED: KB
KENNETH L. BUTTS
ARCHITECT AIA
124 STAGECOACH ROAD
BELL CANYON, CA 91307
(818) 999 -4272
REGISTERED
ARCHITECT
KR4NETH L. BUTTS
STATE OF WASHINGTON
(ADDTti
D• E • 5 • I • G• N
225 OAKLAND RAOD, SUITE 105 TEL: (860)183 -5610
SOUTN WINDSOR, CT 06014 FM: (860)183 -5680
W a-
i m
D co
U
O Z
� Uco
w < �
O -r o tz
I— o : U
D LO
® 1� 0_ cn I— co
41•
V
SHEET TITLE
SCALE
NONE
C1.1
dl
ma
C
l0
STORE NUMBER
SHEET NUMBER
#TBD
REVISIONS
'A'- ISSUE: LANDLORD COMMENTS
DATE: 12/1/09
'EV -ISSUE
DATE
'c'- ISSUE
DATE
'D'- ISSU,
DATE
11Th SHEET
TOTAL AREA 4,000 Sq. F
_ . - , UR - CHEDULE (FIXTURE INDICATED WITH
CLOUD BELOW ARE BY LANDLORD - ACCENT LTG.
BY TENANT)
SYM
MARK
DESCRIPTION
MFG
CATALOG#
LAMP TYPE
VOLTAGE
MOUNTING
REMARKS
2 FLUORESCENT FIXTURE (2) LAMP HIGH
• TPUT T -5
METALUX
2AG- 25414T5 -UNV
(2) 54W/T -5
3500K
UNIV
RECESSED
SUPPLIED /INSTALLED BY L.L.
0
.. 4 FLUORESCENT FIXTURE (2) LAMP HIGH
• ■ TPUT T -5, WITH EMERGENCY BALLAST AND
ci0 MINUTE BATTERY BACK -UP
METALUX
2AG- 254WT5 -UNV
(2) 54W/T -5
3500K
UNIV
RECESSED
SUPPLIED /INSTALLED BY L.L.
w
2 FLUORESCENT FIXTURE
W H PRISMATIC DIFFUSER
METALUX
2GR&- FA232A - UNIV -EBBI
(2) 32W -T8
UNIV
RECESSED
SUPPLIED /INSTALLED BY L.L.
0
4 FLUORESCENT FIXURE WITH PRISMATI
IFFUSER WITH EMERGENCY BALLAST AND q0
MIN. BATTERY
METALUX
2688- FA232A - UNIV -EM -EBBI
(2) 321 -T8
UNIV
RECESSED
SUPPLIED /INSTALLED BY L.L.
•
B
SEMI RECESSED WALL WASH
FIXTURE
CON -TECH
RA841OMHE
10W/EB -II
UNIV
RECESSED
TENANT SUPPLIED /INSTALLED BY G.G.
h�
BIM
CON-TECH
GTL701�WW -P -LF- 100 - I1V
7 0W/E D -17
UNIV
TRACK
MOUNT
TENANT SUPPLIED /INSTALLED BY G.G.
TRACK MOUNTED METAL HALIDE WALL WAS' ICR,
MOUNTED IN SINGLE CIRCUIT TRACK, COLOR
WHI TE
a
2) LAMP FLUORESCENT STRIP
METALUX
SNF -I32- UNV -EB81
(I) 321^11-8
RUBBER COATED
SHATTER PROOF
LAMPS
UNIV
SUSPENDED
SUPT 'LIED /INSTALLED BY L.L.
1 I
- • EDGE -LIT EXIT 516N
NAVILITE
NXESB SERIES
� A
INCLUDED
UNIV
UNIVERSAL
SUPPLIED /INSTALLED BY L.L.
*Zig
qO MIN BATTERY BACK -UP
HOARD LEA EXIT SIGN
q0 MIN BATTERY BACK -UP
ASTRALITE
TP- U- R -W -EM
INCLUDED
UNIV
UNIVERSAL
SUPPLIED /INSTALLED BY L.L.
11■ �
ITH c10 HEAD EMERGENCY
WITH q0 MIN BATTERY BACK -UP
HI
HL -qO -DL
INGULDED
UNIV
SURFACE
SUSPENDED
SUPPLIED /INSTALLED BY L.L.
SEE PLAN FOR LOCATION
8
AUDIO SPEAKERS
REGESSED
TENANT SUPPLIED /INSTALLED BY 6.C.
0
NOTE: SCE ARCHITECTURAL RCP FOR LIGHT FIXTURE QUANTITIES
NEW PANEL " A "
(BY LL)
CONNECT EMERGENCY FIXTURES IN
REAR AREAS TO SAME CIRCUIT AS
GENERAL LIGHTING AHEAD OF LOCAL
SWITCHING IN ACCORDANCE WITH
N.E.C. AS REQURED
FLOOR PLAN - LIGHTING WORK
SCALE. vv • rm
+46 AFF
0
0
DAY
LIGHTING I
0
2 -GANG LIGHT SWITCH -
COVERPLATE
0
S
LIGHTING I
0
0
LIGHTINSALES G I
I LIGHTIN SALES G
PROVIDE PERMANENT,
TYPED LABELS AS SHOWN.
SALES
LIGHTING
SWITCHING DETAIL
NOT TO SCALE
DAYLIGHTING REQUIREMENT
6 -GANG LIGHT SWITCH
COVERPLATE
I ACCENT I
LIGHTING
ACCENT
LIGHTING
-WITCH BANK -SEE
SWITCHING DETAIL
ABOVE
A" 1,3 -15
A"5 -7 - 1 5
RUN EXTRA WIRE
FOR GROUND (BY LL)
(TYPICAL)
SWITCH CONCEALED
FROM VIEW (BY LL)
J -BOX FOR SIGN
(BY LL)
J
LANDLORD WORK UNDER LANDLORD PERMIT
CLARIFICATION OF LOCATION
DAYLIGHTING REQUIREMENT
CURRENT LIMITING DEVICE TO
ALLOW MAXIMUM OF 300 W
1...oci4)47
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
DEC 2 2 2009
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKIMLA
DEC 1 1 2009
PERMIT CENTER
DATE: 11/1$/09
JOB NO: 09 -066
DRAWN: STAP
CHECKED: DP
IV -ISSUE
DATE
'G' -ISSUE
DATE
W
w c
0Z�
CC 0 WCi)
W:C<4
N04:(
= N � co
SHEET TITLE
SCALE
1/4' =1' - O'
SHEET NUMBER
E1.0
STORE NUMBER
#TBD
REVISIONS
'A' -ISSUE / 1 \ LANDLORD WORK UNDER
LANDLORD PERMIT
PATE 12/6/09
FLOOR PLAN
LIGHTING WORK
KEY NOTES (LANDLORD WORK)
®2 PROVIDE (4) 3/4" CONDUITS, (1) DEDICATED P.O.S. CIRCUIT, (1) FOR GENERAL POWER
CIRCUIT, (1) CAT 5 CABLE AND PHONE UNE, (1) SPARE. ROUTE CONDUITES AS SHOWN ON PLAN
DOWN WALL OR COLUMN, STUB CONDUIT INTO FLOOR MOUNTED JUNCTION BOX. ROUTE
FLEXIBLE CONDUIT THROUGH CABINET BASE TO EACH RECEPTACLE. COORDINATE EXACT
CONFIGURATION WITH TENANT REP. AND EXACT LOCATION WITH FIXTURE INSTALLER.
(ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.)
CI PROVIDE 3/4" CONDUIT WITH PULLWIRE FROM CASH /WRAP TO TELEPHONE BACKBOARD IN
STOCKROOM.
O7 QUAD RECEPTACLE AND J -BOX FLUSH MOUNTED IN WALL AT 72" AFF. ROUTE 1"
EMPTY CONDUIT WITH PULLWIRE FROM J -BOX TO 6" ABOVE CEIUNG FOR SPEAKER CABLES.
SPEAKER CABLES ABOVE CEILING SHALL BE IN CONDUIT OR SHALL BE PLENUM RATED.
VERIFY SOUND SYSTEM EQUIPMENT AND REQUIREMENTS WITH SYSTEM SUPPLIER.
® PROVIDE A QUAD RECEPTACLE, GENERAL QUAD RECEPTACLE, FOR GENERAL
PURPOSE POWER AT THE RECEMNG DESK, LOCATED AT 3' -2" A.F.F.
0 DUPLEX IG RECEPTACLE FLUSH MOUNTED VERTICAL AT 10' -0" AFF FOR SECURITY SYSTEM.
10 SUPPLY AND INSTALL THE FOLLOWING SERVICE BELL SYSTEM.
a) EDWARDS #852 PUSHBUTTON MOUNTED AT 48" AFF AT REAR DOOR
b) EDWARDS #88 -50 TRANSFORMER
c) EDWARDS #340 -4G5 BELL MOUNTED ABOVE COORIDOR CEIUNG
d) EDWARDS #340 -4G5 BELL MOUNTED ABOVE CASH/WRAP CEIUNG
11 FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB -IN AND EXTEND AS
REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4" PLYWOOD
BACKBOARD FOR MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT, SIZE AND
SECURE AS REQUIRED. PROVIED ISOLATED GROUND DUPLEX RECEPTACLE FOR POWER TO
TELEPHONE EQUIPMENT. BY LANDLORD.
10 PROVIDE A QUAD IG RECEPTACLE FOR COMPUTER SYSTEM, LOCATED AT 3' -2" A.F.F.
14 RJ31x JACK FOR CHECKPOINT /SECURITY SYSTEM.
KEY NOTES (TENANT WORK)
® THE CIRCUITES USED TO POWER THE CASH REGISTERS /COMPUTERS SHALL NOT BE USED
FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE NEUTRAL OR GROUND WITH OTHER
EQUIPMENT. SEPARATE POWER, NEUTRAL, AND ISULATED GROUND WIRES MINIMUM SIZE #12
AWG SHALL BE RUN TO THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL
BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE CONDUIT FOR
GROUNDING AS THIS MAY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN
SEPARATE CONDUIT. RECEPTACLES SHALL BE HUBBEL #IG -5362 ORANGE.
® DEVICES SURFACE MOUNTED ON CABINET INTERIOR AT 12" AFF. FIELD VERITY LOCATION OF
CABINET SHELVING PRIOR TO INSTALLATION.
® RUN 2 CAT 5 NETWORK CABLES FROM RJ45 JACKS AT CASHWRAP TO RJ45 JACKS AT
RECEMNG TABLE IN STOCKROOM. PROVIDE 18" CABLES AT EACH LOCATION FOR
CONNECTION OF CASH /WRAP HUB AND RECEIVING COMPUTER. CABLES TO BE PLENUM
RATED IF NOT INSTALLED IN CONDUIT. MOUNTED AT 3' -2" A.F.F.
(ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.)
® TGC TO RUN AN EXTRA CABLE THROUGH THE CEIUNG AND LEAVE IT COILED FOR FUTURE
USE. ALARM SYSTEM WIRING TO BE BY VENDOR.
0 JUNCTION BOX FOR SHOPPERTRAK ORBIT. COORDINATE EXACT LOCATION IN FIELD WITH
SHOPPERTRAK REPRESENTATIVE. PROVIDE (1) CAT 5 PLENUM RATED CABLE IN 3/4"
CONDUIT FROM ORBIT LOCATION AT FRONT DOOR TO CONTROLLER LOCATION AT MAIN
TEL /DATA BACKBOARD. CABLE IS BELDEN #1701k LEAVE SUFFICIENT SLACK AT EACH
J -BOX FOR CONNECTION (15' -0" MIN. PER MANUFACTURER'S RECOMMENDATIONS)
(ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.)
LANDLORD WORK UNDER LANDLORD PERMIT
ZONE ADDRESSABLE MODULE
(TYPICAL)
STROBE ONLY
(TYPICAL FOR 3)
NEW HORN /STROBE MOUNTED 80" TO
BOTTOM OF DEVICE OR 6" FROM
CEIUNG-WHICHEVER IS GREATER
(TYPICAL FOR 6)
EOLR
SPRINKLER
TAMPER SWITCH EOLR
SPRINKLER
FLOW SWITCH
18 TSP
(TYPICAL
SIGNALING DEVICES
S S S • • V ♦ • •
V • ♦ • • A • • •
#12 CU-'
AWG
I-NEW PULL STATION
(TYPICAL FOR 3)
(MOUNTED 48" MAX A.F.F.
® ® TO CENTERLINE OF DEVICE)
EOLR
t _ NEW CEIUNG MOUNTED
;FOLK SMOKE DETECTOR (TYPICAL FOR 6)
DUCT MOUNTED SMOKE DETECTOR
(TYPICAL FOR 2)
INITIATING DEVICES
FIRE ALARM SCHEMATIC
NOT TO SCALE
EXTEND AND CONNECT TO LANDLORD MAIN
FIRE ALARM SYSTEM AS REQUIRED.
COORDINATE WITH LANDLORD ALL
CONNECTIONS TO LANDLORD'S SYSTEM.
(BY U_)
11 \- FIRE ALARM INTERFACE
FOR CONNECTION TO LANDLORD'S
CENTRAL FIRE ALARM SYSTEM
TO 4 TTB
® "A "26,28
"A"22
DEDICATED DUPLEX RECEPTACLE
HUBBELL#IG -5362 ORANGE FOR
CASH REGISTER COMPUTER AT
12" AFF /_,
CASH DESK WIRING
SCALES 1/4• - T
ENERAL USE
QUADPLEX HUBBELL
#5362 -WHI AT 12" AFF
FLEXIBLE CONDUIT IN
CABINET BASE
PUSH BUTTON
NEW PANEL "A"
(BY LL)
RECEPTACLE FOR
REFRIGERATOR
(15" A.F.F.)
RECEPTACLE FOR
MICROWAVE
(36" A.F.F.)
UNIT HEATER SUSPENDED
FROM ABOVE
FLOW AND TAMPER SWITCH SHALL BE -�
INSTALLED AS PART OF FIRE ALARM
SYSTEM BY LANDLORD- VERIFY EXACT
LOCATION AND MOUNTING REQUIREMENTS
IN FIELD.
IC -
IC -LL
"A "14,16
"K35
Td BUZZER
r A" 12,18 75
"A"37,39,41
- #12- 1/2"C.
"A"33.••
SEE SHEET E4 FOR SCHEMATIC LAYOUT
OF LOW VOLTAGE INTERFACES DETAIL
UNIT #2 ON ROOF
FIRE ALARM IN RFACE
(BY LL)
SPEAKER
(TYPICAL)
FLOOR PLAN - MISCELLANEOUS
SCALE 1/4• - 1-0
SEE CASH DESK DETAIL
THIS SHEET FOR WIRING
INFORMATION IN THIS AREA
SPEAKER WIRE
(TYPICAL)
NEW DISCONNECT SWITCH
#1 ON ROOF (BY LL)
(60/50, NEMA 3R)
ELECTRIC WORK
"A "32,34,3
3-#8-1/2"C.
FURNISH AND INS
NEW PULL STATION
(TYPICAL -BY LL)
- FURNISH AND INSTALL NEW ACCESSABLE SMOKE
DETECTOR IN RETURN DUCT. PROVIDE AND
INSTALL WIRING 0 FAN INTERLOCK.
(TYPICAL -BY LL,
15' -10"
-ALL DEVICES SHALL BE A MINIMUM 75
CANDELLA AND SHALL COMPLY WITH
NFPA 72 AND ALL OTHER STATE AND
LOCAL REQUIREMENTS.
RECEPTACLE MOUNTED
ABOVE SHOW WINDOW
(TYPICAL FOR 2 -BY LL)
LANDLORD WORK UNDER LANDLORD PERMIT
0`l- o79y
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
DEC 2 2 2009
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 1 1 2009
PERMIT CENTER
DATE: 11/18/09
JOB NO: m9 -066
DRAWN: 8tAPP
CHECKED: PP
Q
- 0
SI -ISSUE
DATE
'C'- ISSUE
PATE
Nri
C
5
•
tu
E
STORE NUMBER
itTBD
REVISIONS
A'
' A LANDLORD WORK UNDER
LANDLORD PERMIT
PATE 12/6/09
SHEEP TITLE
FLOOR PLAN
MISCELLANEOUS
ELECTRIC WORK
SCALE
1/4' =1' - O'
SHEET NUMBER
E2.O
PANEL NEW PANEL "A" BY LL
LUGS
MAIN
225 AMP
120/208 VOLT 3 PHASE 4 WIRE
BREAKER
200 AMP
USE
CKT.
NO.
LOAD
BKR
SIZE
A B C
BKR
SIZE
LOAD
CKT.
NO.
USE
SALES AREA LIGHTS
1
1188
20
1200
2
SIGN
!,
i..�
A•
IIII
01
1
0
011
A.
�M
x.
in"
N
1��
am
r.a
^ ••�
VIER
PI
..A
011
ill
01
011
di
3
972
394
4
STORE FRONT LIGHTS
5
1080
394
6
7
864
280
8
TRACK LIGHTING
ACCENT LIGHTS
9
700
360
10
SHOW WINDOW RECPT.
11
630
1200
12
MICROWAVE
REAR AREA LIGHTS
13
714
180
14
SECURITY SYSTEM
IA
EM /NIGHT LIGHTS
15
727
500
16
TTB RECPT.
..�
T.E. FANS
17
180
660
18
REFRIGERATOR
REC. DESK IG
19
360
—
20
SPARE
E A
REC. DESK RECPT.
21
360
1440
22
CASH DESK RECPT.
••�
HOT WATER HEATER
23
1500
360
24
HVAC RECPT.
MANAGERS DESK IG
25
500
1000
26
CASH REGISTER
MANAGERS DESK RECPT
27
36 0
100
28
SOUND SYSTEM
29
500
—
30
SPARE
SHOPPER TRACK SYSTEM
31
1000
4 �
/3
5200
32
GENERAL RECPT.
33
1440
5200
34
A.C. UNIT #
TOILET ROOM RECPT.
2 � /3
•
37
1666
3 /3
3543
38
UNIT HEATER
39
1666
3543
40
A.C. UNIT #2
41
1666
3543
42
TC1
TC1
TC1
TC1
TC2
TC2
*
" *" INDICATES PANEL LOCKS
"TC#" INDICATES TIME CLOCK
2" RIGID INSULATION
CONCRETE
ENCASED
ELECTRODE
PANEL DIRECTORY
PHASE A: 17695 WATTS
PHASE B: 18662 WATTS
PHASE C: 17273 WATTS
TOTAL: 53630 WATTS
GROUNDING SHALL CONSIST OF COPPER CONDUCTORS IN CONDUIT WITH BOLTED, OR
BRAZED, CONNECTION TO EACH ILLUSTRATION BELOW FOR THE NEUTRAL. GROUNDING AND BONDING
SHALL COMPLY WITH NEC ARTICLES 230 & 250. ALL METALLIC RACEWAYS SHALL BE GROUNDED
1 b 1
BUILDING
STEEL
WATER (2) -3/4 "X10'
SERVICE GROUND RODS
PIPING
BALANCE: 7.44 %
GROUND PER NEC —\
SPECIAL NOTE: IG AND GFI RECEPTACLES SHALL BE RATED AT 20
AMPERES AND SHALL HAVE A DEDICATED INSLUATED GREEN GROUND
WIRE, THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPUCED
BETWEEN THE DEVICE AND THE PANEL GROUND BUS
TC3
TC2
TC2
TC3
*
SUGGESTED SERVICE GROUND DETAIL
NOT TO SCALE
GALVANIZED SHEET METAL HOOD
FILL VOID WITH
FIBERGLASS INSULATION
1" CONDUIT
ROOF DECK —
(VERIFY EXACT CONSTRUCTION
AND PENETRATE AS REQUIRED)
SHEET METAL OR FLEX —TUBE COLLAR
WOOD NAILER— PROVIDE
FASTNERS 24" O.C. MAX.
26 GA. COUNTERFLASHING 12" MIN.
ROOF FELTS AND FLASHING
CONDUIT THRU ROOF DETAIL
NOT TO SCALE
PAWL "A" FEEDER
LCL
signage, general lighting, aash re(lister, unit heater, ett.
haru•windouu or entnf lighting (at shouuwindcw)
track lighting
s tra& lighting(shatrrwin
x" a.c. equipment(rt% ahu, cu, etc.)- 484 volt
x" a a equipment(rtu, ahu, cu. etc.)- 208 volt
Sub Total
NON LCL
water heater. sensormatic, traffic counter, misc., etc,
"r recep tact es
""s how window lighting requirement in feeder only)
Sub Total
TOTAL
INPUT
280
0
75.0:I
x#1.36
1$
a
723
1Z
27
FACTOR
1.25
1.25
75.03
360.23
1
13t57P
357
0
1200
0
26227
12253
5443
30
VA
41355
21218
62573
4:10 wR - total amperage egauls
fQ 208 volt • -vtal amperage egavls
75.3
173,7
Track . . Ming calculated per 2005 NEC .,`Srti cle 220 43(B)
" MCA used includes 125% of largest mrltgr per 2445 NEC Aril ole220.18(A)
xxx
Receptacles aaloulated per 2605 NEC Article 220.44
xxxx $
GRADE
1st 10kwa 103% All other 50%6
200 VA per LF ofshouu- rnindow minus actual lighting
NEW METER FOR SPACE BY LL
EX. METER SOCKET FOR SPACE
PROVIDED BY LL
0
0
EX. 200 AMP DISCONNECT
FOR SPACE PROVIDED BY LL
r,
RISER DIAGRAM NOTES
1. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT
RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT
BREAKER AND ALL BRANCH DEVICES AS REQUIRED.
2. CONTRACTOR TO MAINTAIN ALL REQUIRED
CLEARENCES PER ARTICLE 110 -26 NEC
APPROX. 125' -0"
TIMECLOCK #1 FOR AUTOMATIC
LIGHTING CONTROL /SHUTOFF IN
ACCORDANCE WITH THE 2006
WASHINTON STATE ENERGY CODE
TIMECLOCK #1 FOR AUTOMATIC
LIGHTING CONTROL /SHUTOFF IN
ACCORDANCE WITH THE 2006
WASHINTON STATE ENERGY CODE
TYPE
O CKT
V
I
SERVICE TO SPACE TO BE 120/208 VOLT, 3PH,
4W., 200 AMP BY LANDLORD
(4— #3/0 -2" C. MIN. —SEE NOTE 3 BELOW)
SYMBOLS AND ABBREVIATIONS
RECESSED
INCANDESCENT FIXTURE
SINGLE POLE SWITCH
DUPLEX WALL RECEPTACLE
QUADRAPLEX ISOLATED GROUND RECEPTACLE
GROUND FAULT QUADRAPLEX WALL RECEPTACLE
QUADRAPLEX WALL RECEPTACLE
WEATHERPROOF RECEPTACLE
JUNCTION BOX
TELEPHONE OUTLET
TELEPHONE /DATA OUTLET
DATA OUTLET
TELEPHONE CONDUIT
T.T.B. TELEPHONE TERMINAL BOARD
FIRE ALARM SYMBOLS AND ABBREVIATIONS
Q SMOKE DETECTOR (SIMPLEX #4098 -9714)
DUCT SMOKE DETECTOR (SIMPLEX #4098 -9756)
PULL STATION (SIMPLEX #4099 -9001)
O
P
S
75 HORN /STROBE (EQUAL TO SIMPLEX SERIES #4904 -9351 — COORDINATE
1� EXACT REQUIREMENT FOR DEVICES WITH SIMPLEX)
S INDICATES CANDELLA RATING OF DEVICE
V75 SPEAKER STROBE (EQUAL TO SIMPLEX SERIES 4903 -9451 — COORDINATE
EXACT REQUIREMENT FOR DEVICES WITH SIMPLEX)
CANDELLA RATING OF DEVICE
3— #8- 1/2"C. MIN.
(BY LL)
TC1
TC2
ELECTRIC RISER DIAGRAM
NOT TO SCALE
do- 3- #8- 1/2"C. MIN.
(BY LL)
TC3
--r. 2,8
NEW PANEL "A"
3. AT TIME OF DESIGN 1 3/4" CONDUIT PRESENTLY EXISTS TO SPACE.
SERVICE SIZE, WIRE SIZE, TYPE, AND INSTALLATION IS UNKNOWN.
CONTRACTOR TO VERIFY EXISTING SERVICE AND INSTALLATION TO SPACE
IS ADEQUATE WITH THE NEW DESIGN MINIMUM SERVICE SIZE, WIRE SIZES,
ETC SHOWN ABOVE IN THE DIAGRAM. IF ANY PORTION OF EXISTING
INSTALLATION IS INADEQUATE PER THE NEW DESIGN, CONTRACTOR SHALL
INSTALL TO ACCOMODATE THE DESIGN. (BY LL)
0
S � i S
S �I S
EX
$OC
NEW DISCONNECT SWITCH #1
[4 — ON ROOF BY LL
(60/50, NEMA 3R MIN.)
NEW DISCONNECT SWITCH #2
ON ROOF BY LL
(60/45, NEMA 3R MIN.)
NEW TIME CLOCK
(TYPICAL FOR 3)
PUSHBUTTON
[�B BUZZER
A TRANSFORMER
MCA MINIMUM CIRCUIT AMP
MOCP MAXIMUM OVERCURRENT PROTECTION
CONDUIT ABOVE FLOOR
CONDUIT BELOW FLOOR > MARKS INDICATE NUMBER OF WIRES
HOME RUN CONDUIT
EXISTING TO REMAIN
EXR EXISTING RELOCATED
SHTR SHOPPERTRACK
D DATA
T TELEPHONE
F FAX
M MODEM
OCCUPANCY SWITCH
LL LANDLORD INSTALLED
l e— NEW A.C. UNIT #1 ON ROOF
(BY LL)
NEW A.C. UNIT #2 ON ROOF
(BY LL)
LANDLORD WORK UNDER LANDLORD PERMIT
A
CLARIFICATION FOR MAIN LUG ONLY
TIMECLOCK #1 FOR AUTOMATIC
LIGHTING CONTROL /SHUTOFF IN
ACCORDANCE WITH THE 2006
WASHINTON STATE ENERGY CODE
EtD O7'I
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 NEC
DEC 2 2 2009
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWIIA
DEC 1 2009
PERMIT CENTER
DATE: 11/1/3/09
JOB NO: 09 - 066
DRAWN: STAFF
CHECKED: DP
W
ir
a W
oo
0 Z�
CC 0 W
wi<4
Z
kii0<f±'
O � �
W - ISSUE /1
DATE
'8' -ISSUE
DATE
'C' -ISSUE
DATE
STORE NUMBER
itTBD
SHEET TITLE
ELECTRICAL
DETAILS
SCALE
1/4 " =1' - 0 *
SHEET NUMBER
E3.0
C
.0
LL
d
m
O
REVISIONS
LANDLORD WORK UNDER
LANDLORD PERMIT
12/6/09
IA CKUP MDT
NOTE:
REGISTER 1
UNE 2
HUB
CASHWRAP
REGIS1ER 2
8" RADIUS
PROVIDE COVER PLATES
COLOR SELECTED BY
ARCHITECT
REGISTER 3
CAM OWP
PAS LKE 1
ao
K1fOCM LFE 2
LEXMARK
PRINTER
TELEPHONE
L94E 1
BUSHING WITH PULL STRING
STUBBED TO ACCESSIBLE
LOCATION ABOVE CEILING
(1) 1" CONDUIT
TO ACCESSIBLE
SPACE IN CEILING
(2) GANG DEEP BACK BOX
WITH SINGLE GANG EXTENSION
BOX 18" AFF- VERIFY WITH
ARCHITECT
SCANNER
BACK OFFICE PC
PRINTER
MANAGER'S OFFICE
RECEIVING DESK
LRE 2
DIAL
BAdO P
FAX
SCHEMATIC LAYOUT OF
LOW VOLTAGE INTERFACES
NOT TO SCALE
TELEPHONE /DATA RISER DETAIL
NOT TO SCALE
CEILING
FLOOR
ROUTER
TYPICAL WHEN ANY OF THE FOLLOWING SYMBOLS Y V AND SZ ARE SHOWN ON PLAN.
PROVIDE AS SHOWN ABOVE
MODEM
MANAGER'S DESK
Yfit KFF1fE
It
FAX AMINE
TELCO DEIAARK
56K OR
I A
RE
RA -31X H
FOR
ALAR4
EEG.% DESK
UNE 2
FROM TM:
RECEIVING DESK HAS 4 BOXES.
(1) RJ45 FOR LINK TO CASH
WRAP, (1) FOR UNE 1, (1) FOR
UNE 2, FOR 56 K CIRCUIT
UNE 1 GOES TO THE
MANAGER'S OFFICE, THE
RECEIVING DESK AND THE
CASH WRAP VIA THE
RECEIVING DESK.
UNE 2 GOES TO THE CASH
WRAP AND THE RECEIVING
DESK
UNE 3 GOES TO THE
MANAGER'S OFFICE FAX
MACHINE
RECEIVING DESK
DATA/TELEPHONE FACEPLATE REQUIREMENTS
REGISTER 1
L2 # # ##
rl�r
i= 1 r
POS1 POS2
I
t
RECEIVING DESK
SHOPPERTRAK
f
POWER DATA
J
1
I
REGISTER4
1
1 ® J
MANAGER'S OFFICE
C
1
I
ELO 019 )-I
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
DEC 2 2 2009
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKW ILA
DEC 1,`1 2009
PERMIT CENTER
DATE: II/15 /09
JOB NO: 09
DRAWN: STAFF
CHECKED: DP
1 '
Q
U
W O-
CC cc
a
Oz T
CO W 00
W=<4
•
W �®
voaZ CD
I- O
L : U
N W
co r 1— CA
4.0
co
V
SHEET TITLE
STORE NUMBER
%TBD
REVISIONS
'N.-ISSUE/1\ LANDLORD WORK UNDER
LANDLORD PERMIT
PATE 12/6/09
'IS' -ISSUE
DATE
'C' -I88UE
DATE
LOW VOLTAGE
DIAGRAMS
SCALE
1/4 * =1' - 0"
SHEET NUMBER
E4.0
C
1
L1 ####
I I I
L2 ####
-1
CIRCUIT
I ... ,
1
POS 1 POS 2
1
- I
1 (cam)
IA CKUP MDT
NOTE:
REGISTER 1
UNE 2
HUB
CASHWRAP
REGIS1ER 2
8" RADIUS
PROVIDE COVER PLATES
COLOR SELECTED BY
ARCHITECT
REGISTER 3
CAM OWP
PAS LKE 1
ao
K1fOCM LFE 2
LEXMARK
PRINTER
TELEPHONE
L94E 1
BUSHING WITH PULL STRING
STUBBED TO ACCESSIBLE
LOCATION ABOVE CEILING
(1) 1" CONDUIT
TO ACCESSIBLE
SPACE IN CEILING
(2) GANG DEEP BACK BOX
WITH SINGLE GANG EXTENSION
BOX 18" AFF- VERIFY WITH
ARCHITECT
SCANNER
BACK OFFICE PC
PRINTER
MANAGER'S OFFICE
RECEIVING DESK
LRE 2
DIAL
BAdO P
FAX
SCHEMATIC LAYOUT OF
LOW VOLTAGE INTERFACES
NOT TO SCALE
TELEPHONE /DATA RISER DETAIL
NOT TO SCALE
CEILING
FLOOR
ROUTER
TYPICAL WHEN ANY OF THE FOLLOWING SYMBOLS Y V AND SZ ARE SHOWN ON PLAN.
PROVIDE AS SHOWN ABOVE
MODEM
MANAGER'S DESK
Yfit KFF1fE
It
FAX AMINE
TELCO DEIAARK
56K OR
I A
RE
RA -31X H
FOR
ALAR4
EEG.% DESK
UNE 2
FROM TM:
RECEIVING DESK HAS 4 BOXES.
(1) RJ45 FOR LINK TO CASH
WRAP, (1) FOR UNE 1, (1) FOR
UNE 2, FOR 56 K CIRCUIT
UNE 1 GOES TO THE
MANAGER'S OFFICE, THE
RECEIVING DESK AND THE
CASH WRAP VIA THE
RECEIVING DESK.
UNE 2 GOES TO THE CASH
WRAP AND THE RECEIVING
DESK
UNE 3 GOES TO THE
MANAGER'S OFFICE FAX
MACHINE
RECEIVING DESK
DATA/TELEPHONE FACEPLATE REQUIREMENTS
REGISTER 1
L2 # # ##
rl�r
i= 1 r
POS1 POS2
I
t
RECEIVING DESK
SHOPPERTRAK
f
POWER DATA
J
1
I
REGISTER4
1
1 ® J
MANAGER'S OFFICE
C
1
I
ELO 019 )-I
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
DEC 2 2 2009
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKW ILA
DEC 1,`1 2009
PERMIT CENTER
DATE: II/15 /09
JOB NO: 09
DRAWN: STAFF
CHECKED: DP
1 '
Q
U
W O-
CC cc
a
Oz T
CO W 00
W=<4
•
W �®
voaZ CD
I- O
L : U
N W
co r 1— CA
4.0
co
V
SHEET TITLE
STORE NUMBER
%TBD
REVISIONS
'N.-ISSUE/1\ LANDLORD WORK UNDER
LANDLORD PERMIT
PATE 12/6/09
'IS' -ISSUE
DATE
'C' -I88UE
DATE
LOW VOLTAGE
DIAGRAMS
SCALE
1/4 * =1' - 0"
SHEET NUMBER
E4.0
LANDLORD WORK UNDER LANDLORD PERMIT
CLARIFICATION
ELECTRICAL EQUIPMENT AND MATERIAL
UNIT HEATER: TRANE #UHEC- 052AACA, HORIZONTAL, 5 KW, 208 VOLT, 3 PH., 60 HZ,
COMPLETE WITH HORIZONTAL WALL /CEILING SWIVEL MOUNTING BRACKET, 24 VOLT
CONTROL TRANSFORMER AND ROOM THERMOSTAT.
.
PANEL A: SQUARE D TYPE NQODCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3 PH., 4 WIRE.
A.C. UNIT DISCONNECT SWITCH: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 60 AMP, 240 VOLT, FUSIBLE, WITH FUSES AS SHOWN IN PLAN AND NEMA 3R
ENCLOSURE.
SQUARE D #H322.
A.C. UNIT DISCONNECT SWITCH: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 60 AMP, 240 VOLT, FUSIBLE, WITH FUSES AS SHOWN IN PLAN AND NEMA 3R
ENCLOSURE.
SQUARE D #H322.
TIME CLOCK #1: TORK #W -4001, 4PST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH MANUAL OVERRIDE AND 24 HOUR RESERVE POWER FEATURE IN ACCORDANCE WITH THE
2001 IECC.
TIME CLOCK #2: TORK #W -300L, 3PST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH MANUAL OVERRIDE AND 24 HOUR RESERVE POWER FEATURE IN ACCORDANCE WITH THE
2001 IECC.
TIME CLOCK #3: DPST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH RESERVE POWER FEATURE. TORK #W220L.
RECEPTACLES: HUBBELL #5362.
GROUND FAULT RECEPTACLES: HUBBELL #GF_5362.
ISOLATED GROUND RECEPTACLES: HUBBELL #IG- 5362.
"QUAD" RECEPTACLES: TWO (2) HUBBELL #5362 DUPLEX RECEPTACLES IN A COMMON JUNCTION WITH A 4 GANG COVER PLATE.
CASH REGISTER RECEPTACLES: TWO (2) HUBBELL #IG -5362 DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE.
TELEPHONE /MODEM OUTLETS: HUBBELL TYPE RJ11 WITH COVER PLATE.
DATA OUTLETS: HUBBELL TYPE RJ45 WITH COVER PLATE.
SINGLE POLE SWITCHES: HUBBELL #HBL -1221.
THREE WAY SWITCHES: HUBBELL #HBL- 1223_I.
OCCUPANCY SWITCHES: LEVITON, MODEL #PR180 -1 LA OR EQUAL.
COVERPLATES: HUBBELL, COLOR TO BE COORDINATED WITH OWNER AND /OR ARCHITECT.
PUSHBUTTON: EDWARDS #1786C_B.
SIGNAL TRANSFORMER: EDWARDS #596.
BUZZERS: EDWARDS #15_OAJ.
DUCT SMOKE DETECTOR: SIMPLEX #4098 -9686.
PORCELEIN CEILING MOUNTED LAMP HOLDER: GENERAL ELECTRIC, MODEL #GE- 5740 -7 FOR
USE WITH SWITCH, COMPLETE WITH 100 WATT TYPE "A" LAMP.
ELECTRICAL WORK NOTES
1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS.
2. THE SPACE IS NEW AND HAS NOT PREVIOUSLY BEEN OCCUPIED. REMOVE EXISTING LIGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, WIRE, ETC., NOT REQUIRED
FOR THE NEW INSTALLATION. UNUSED FIXTURES SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE.
3. FURNISH AND INSTALL A NEW 120/208 VOLT 3PH., 4W. 200 AMP SERVICE TO THE SPACE FROM THE LANDLORD ELECTRICAL LOCATION, INCLUDING BUT NOT UMITED TOO,
MAIN DISCONNECT, METER, METER SOCKET, CONDUIT, WIRING, ETC.
4. NEW SERVICE SHALL BE A PART OF THE ELECTRICAL CONTRACT. COORDINATE ALL REQUIRED WORK AT DISTRIBUTION LOCATION WITH LANDLORD TO ENSURE
COMPATIBILITY /ACCEPTABILITY /AVAILABILITY OF SERVICE AS REQUIRED AND INDICATED. IF ANY ISSUES ARISE WITH REGARD TO SERVICE SIZE AND AVAILABILITY OF CERTAIN
SIZED DISTRIBUTION EQUIPMENT, CONTACT ARCHITECT AND /OR ENGINEER PRIOR TO BID FOR DISPOSITION. BASE BID SHALL INCLUDE ALL REQUIRED WORK AT LANDLORD'S
DISTRIBUTION LOCATION AND SHALL BE COMPLETE IN EVERY ASPECT AS REQUIRED TO ACCOMMODATE NEW SERVICE. NO EXTRAS WILL BE ALLOWED FOR WORK NOT
INCLUDED IN BASE BID.
5. FURNISH AND INSTALL ONE (1) 120/208, 200 AMP, 42 CIRCUIT ELECTRICAL PANEL WITH MAIN LUG ONLY.
6. THE CONTRACTOR SHALL FURNISH AND INSTALL TWO (2) NEW A.C. UNITS ON ROOF
ABOVE THE SPACE. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
POWER WIRING, CONDUITS, DISCONNECT SWITCHES, OVERCURRENT PROTECTION, ETC. FOR THE NEW A.C. SYSTEMS AS SHOWN AND REQUIRED FOR A COMPLETE
INSTALLATION AS REQUIRED.
7. CONNECT ALL CIRCUITS TO PANEL AS REQUIRED. ALL CIRCUITS SHALL BE ARRANGED ON THE PANEL IN STRICT ACCORDANCE WITH THE NUMBERS SHOWN ON THE
DRAWINGS. NO VARIATION OR DEVIATION FROM THE DRAWING WILL BE ACCEPTED. ANY CHANGE IN CIRCUITING DUE TO ACTUAL FIELD CONDITION MUST BE APPROVED BY
THE ENGINEER PRIOR TO AFFECTING THE CHANGE. ANY WORK PERFORMED ASIDE FROM THAT SHOWN, INDICATED OR IMPLIED MUST BE APPROVED BY THE PROJECT
MANAGER AND /OR ENGINEER BEFORE STARTING. ALL UNUSED CIRCUITS SHALL BE UTIUZED AS SPARES.
8. VERIFY SIZE, LOCATION AND WIRING REQUIREMENTS FOR ALL EQUIPMENT WHICH WILL BE UTILIZED. REPORT ANY DISCREPANCIES, FROM THAT CAI I FD FOR ABOVE, TO THE
ARCHITECT AND /OR ENGINEER FOR DISPOSITION.
9. MAINTAIN ALL REQUIRED CLEARANCES AT ALL ELECTRICAL EQUIPMENT, INCLUDING, BUT NOT LIMITED TOO DISCONNECT SWITCH(ES) AND ELECTRICAL PANELS, IN STRICT
ACCORDANCE WITH N.E.C. ARTICLE 110. RELOCATE ANY /ALL EQUIPMENT AND ASSOCIATED POWER (INCLUDING RECEPTACLES, WIRING, CONDUIT, ETC.) THAT CONFLICTS WITH
THE REUSE OF THIS EQUIPMENT IN THEIR PRESENT LOCATIONS AS REQUIRED. CONTACT THE PROJECT MANAGER TO COORDINATE THIS PORTION OF THE WORK IF
REQUIRED.
10.TEMPERATURE CONTROL WORK WILL BE A PART OF THE MECHANICAL CONTRACT. ALL CONTROL WIRING SHALL BE IN CONDUIT.
11.FURNISH AND INSTALL NEW TELEPHONE TERMINAL BOARD IN LOCATION SHOWN. NEW TELEPHONE TERMINAL BOARD SHALL BE 12" X 24" PLYWOOD, 3/4" THICK, MOUNTED
ON WALL, READY TO RECEIVE TELEPHONE EQUIPMENT.
12.AFTER CONSTRUCTION IS COMPLETE, FIELD VERIFY THE EXTENT OF ALL EQUIPMENT IN ALL AREAS AND ENSURE THAT ALL CONNECTIONS AND OR INTERFACES BETWEEN
DEVICES IN THE VARIOUS AREAS OF THE BUILDING ARE MET AS REQUIRED. CONTACT FIELD REPRESENTATIVE TO COORDINATE THIS PORTION OF THE WORK AS APPLICABLE.
13. PROVIDE TEMPORARY WIRING AS REQUIRED WHILE SERVICE IS BEING INSTALLED TO ALLOW FOR LIGHTING AND POWER FOR CONSTRUCTION PURPOSES. WHEN INSTALLING
NEW SERVICE, KEEP SHUTDOWN TIME TO A MINIMUM.
14. SEE ARCHITECTURAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE, EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC.
15.REFER TO CARTERS RETAIL REQUIRED DELIVERY CONDITION DOCUMENT, SCHEDULE A FOR CLARIFICATION ON ANY ISSUES NOT MENTIONED IN CONTRACT DOCUMENTS. IF
CONFLICTS OCCUR BETWEEN CONSTRUCTION DOCUMENTS AND SCHEDULE A, CONTACT THE ARCHITECT AND /OR ENGINEER FOR DISPOSITION PRIOR TO BID OR INSTALLATION.
TELEPHONE GENERAL NOTES
1. FURNISH AND INSTALL A 2' X 3' X 3/4" TELEPHONE TERMINAL BOARD WITH DEDICATED RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND FOR USE WITH THE TELEPHONE
SYSTEM. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY.
2. COMMUNICATIONS CONTRACTOR SHALL INSTALL A COMPLETE AND OPERABLE TELEPHONE SYSTEM. SAID CONTRACTOR SHALL SUPPLY ALL LABOR, PREMISE WIRE, WIRE
BLOCKS, TELEPHONE JACKS AND OTHER NECESSARY APPURTENANCES TO COMPLETE IN EVERY DETAIL.
3. SYSTEM SHOWN IS SCHEMATIC AND EXACT LOCATION SHALL BE DETERMINED BY ALL SITE CONDITIONS.
4. TELEPHONE CABLES SHALL BE INSTALLED IN CONDUIT (WHERE REQUIRED) ABOVE THE SUSPENDED CEILING. IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE
- CABLING RUN THROUGHOUT STORE IN THE PLENUM AREA SHALL BE SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE - EITHER WAY,
ORDERLY RUNS AND ATTACHMENT TO JOISTS ARE REQUIRED. SAID CONTRACTOR SHALL CONFIRM ALL REQUIREMENTS WITH OWNER, GENERAL CONTRACTOR AND LOCAL
CODE AUTHORITY BEFORE INSTALLING ANY CABLE.
5. OWNER WILL HAVE A FIVE (5) LINE SYSTEM. COORDINATE ALL REQUIREMENTS WITH THE LOCAL UTILITY.
A. LINES 1 THROUGH 5 WILL BE USED FOR VOICE, FAX OR MODEM AS DIRECTED BY THE OWNER. REFERENCES TO NUMBERS 6 -8 (9) ON THE SCHEMATICS ARE FOR
OTHER LOW VOLTAGE SYSTEMS IN THE SPACE PROVIDED BY OTHERS.
6. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY TELEPHONE SERVICE FOR USE BY OWNER AND SELF DURING CONSTRUCTION. CONNECTION FEES AND SERVICE FEES
SHALL BE PAID BY GENERAL CONTRACTOR.
7. GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER AND LOCAL UTILITY COMPANY (IF REQUIRED) TO SUPPLY THE TELEPHONES THROUGHOUT THE SPACE FOR THE
PROJECT.
ELECTRICAL WORK NOTES - GENERAL
1. THE ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS.
2. ELECTRICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED,
SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE
WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT.
3. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO
EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT.
4. ELECTRICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK.
5. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY.
AT NO TIME SHALL ANY WORK BE UNDERTAKEN WHICH SHALL INTERFERE WITH THE NORMAL OPERATION OF BUSINESS. ANY SHUTDOWN MUST OCCUR AFTER REGULAR
BUSINESS HOURS AND MUST BE CLEARED WITH THE MANAGEMENT WITH PROPER PRIOR NOTICE GIVEN TO THE OWNER'S REPRESENTATIVE.
6. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS, OMISSIONS OR DISCREPANCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK,
OR, FAIUNG SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER.
7. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE.
8. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER /ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY
FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS.
9. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR
GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT.
10.WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT.
11.ALL WIRE SHALL BE COPPER. MINIMUM SIZE #12 AWG. ALL CONDUCTORS #10 AND SMALLER SHALL HAVE TYPE "THHW" INSULATION. CONDUCTORS LARGER THAN #10
SHALL HAVE TYPE "THHN" INSULATION.
12.ALL WIRE SHALL BE IN CONDUIT AND SHALL BE CONCEALED FROM VIEW. EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES PARALLEL WITH OR PERPENDICULAR
TO COLUMN LINES OR BEAMS AND SHALL BE SEPERATED BY AT LEAST 3" INCHES FROM DOMESTIC WATER LINES WHENEVER ALONG SIDE OR ACROSS SUCH UNES.
ROMEX IS NOT PERMITTED. FLEXIBLE CONDUIT OR TYPE MC CABLE MAY BE USED FOR FIXTURE AND EQUIPMENT CONNECTIONS ONLY, AND WHERE SO USED SHALL BE
GROUNDED WITH A SEPERATE FULL SIZED GREEN GROUNDING CONDUCTOR. FLEXIBLE CONDUIT CONNECTIONS SHALL BE LIMITED TO 3' -O" IN LENGTH. CONDUIT EXPOSED
TO WEATHER SHALL BE RIGID. ALL OTHER CONDUIT SHALL BE EMT. CONDUIT FITTINGS SHALL BE COMPRESSION OR THREADED TYPE, USE OF SET SCREW FITTINGS IS
NOT ACCEPTABLE.
13.CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT IN UNFINISHED AREAS MAY BE EXPOSED.
14.HOME RUNS OVER 100' IN LENGTH SHALL BE #10 WIRE.
15.CONTRACTOR SHALL ENSURE THAT ENTIRE INSTALLATION IN ACCORDANCE WITH N.E.C. ARTICLE 110 -26 AND THAT ALL REQUIRED OPERATING AND MAINTENANCE CLEARANCES
ARE MAINTAINED AND ACCOUNTED FOR. ADJUSTMENTS TO LAYOUT SHOWN TO ACCOMMODATE CLEARANCE REQUIREMENTS SHALL BE DISCUSSED WITH ARCHITECT AND /OR
ENGINEER SO AS TO MINIMIZE IMPACT ON OTHER SYSTEMS. CONTACT ARCHITECT AND /OR ENGINEER FOR DISPOSITION.
16.CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND BRANCH DEVICES AS REQUIRED.
17.SEAL ALL PENETRATIONS THROUGH WALLS, CEIUNGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT.
18.PROVIDE ENGRAVED BAKEUTE NAMEPLATES FOR ALL ELECTRICAL SERVICE EQUIPMENT INCLUDING DISCONNECT SWITCHES, PANELS, PUSHBUTTONS AND STARTERS.
19.LIGHTING CIRCUITS WHICH ARE SWITCHED AT PANELS SHALL BE FITTED WITH TYPE "SWD" BREAKERS SUITABLE FOR SWITCHING SERVICE.
20.FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORY(IES). IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. FURNISH AND INSTALL AN ENGRAVED NAMEPLATE
ON THE WALL ABOVE THE SINGLE RECEPTACLE IN THE REAR AREA FOR HANDHELD STEAMER IDENTIFYING IT AS SUCH.
21.FURNISH TWO (2) COPIES IES OF THE ELECTRIC RISER DIAGRAM AND PANEL DIRECTORY(IES) TO THE TENANT FOR REVIEW AND APPROVAL, OR SUBMIT A LETTER TO THE
TENANT CONFIRMING THAT THE SYSTEM WAS INSTALLED AS PER PLANS AND SPECIFICATIONS.
22.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT.
23.FURNISH AND INSTALL PANEL LOCKS WHERE SHOWN ON THE DRAWINGS.
24.WIRE EMERGENCY BALLAST AND BATTERY UGHTS ON SAME CIRCUIT IN AREA AND AHEAD OF LOCAL SWITCHING.
25.EXTERIOR SIGNAGE WILL BE FURNISHED AND INSTALLED BY SIGN CONTRACTOR. CONNECT TO SIGNS AND PROVIDE POWER AS REQUIRED FOR A COMPLETE INSTALLATION.
COORDINATE THIS PORTION OF THE WORK WITH THE SIGN CONTRACTOR AND LANDLORD AS REQUIRED.
26.SOME LIGHTING FIXTURES WILL BE FURNISHED BY THE OWNER. PROCURE UGHTING FIXTURES FROM OWNER AND INSTALL THEM IN THE LOCATIONS SHOWN AS REQUIRED.
CONTACT THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING A PROPOSAL TO DETERMINE WHICH FIXTURES (IF ANY) ARE NOT FURNISHED BY THE OWNER. INSTALL ALL
FIXTURES (OWNER FURNISHED AND CONTRACTOR FURNISHED) AS REQUIRED FOR A COMPLETE INSTALLATION. LEAVE PROTECTIVE COVERING /FILM IN PLACE ON FIXTURES
UNTIL FINAL CLEAN -UP. INSTALL UGHTING FIXTURES IN RATED CEILING SO AS TO MAINTAIN INTEGRITY OF RATING. REPLACE ANY LAMPS THAT HAVE EXPIRED DURING
CONSTRUCTION AND MAKE ALL ADJUSTMENTS TO FIXTURES FOR DIRECTION AS REQUIRED PRIOR TO COMPLETION.
27.SWITCHES, NOT OTHERWISE CALLED OUT, SHALL BE MOUNTED 4'_6" ABOVE FLOOR.
28.RECEPTACLES AND TELEPHONE OUTLETS IN SALES AREA SHALL BE MOUNTED AT 18" A.F.F. UNLESS NOTED. RECEPTACLES AND COVERS SHALL BE AS CALLED FOR IN THE
SPECIFICATIONS.
29.ALL COVERPLATES FOR ALL DEVICES SHALL BE AS REQUIRED TO MATCH ADJACENT FINISHES - COORDINATE WITH ARCHITECT.
30.VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES
AND FLANGES AS REQUIRED.
31.IG AND GFI RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WIRE, THE GROUND WIRE SHALL BE RUN
CONTINUOUS AND UNSPUCED BETWEEN THE DEVICE AND THE PANEL GROUND BUS.
32.MOUNTING HEIGHTS OF EQUIPMENT NOT SPECIFICALLY CALLED FOR ARE NOTED ON ARCHITECTURAL DRAWINGS - SEE ARCHITECTURAL DRAWINGS TO COORDINATE.
33.SUPPORT ALL FIXTURES ACROSS CEILING TEES OR FROM STRUCTURE ABOVE. IN NO CASE SHALL CEILING TILES OR PLASTER CEILING SUPPORT ANY FIXTURES. ,
34.SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. AND SYMBOLS LIST, FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION
REQUIREMENTS.
35.THE OWNER WILL FURNISH AND INSTALL A COMPUTER SYSTEM (CASH REGISTERS AND COMPUTERS) FOR THE SPACE. CONTRACTOR SHALL FURNISH AND INSTALL CONDUITS
WITH CATEGORY 5 CABLING FROM ONE LOCATION TO ANOTHER (VARIOUS PLACES) IN ALL LOCATIONS SHOWN ON THE DRAWINGS - EITHER IN PLAN OR IN THE SCHEMATIC
WIRING DIAGRAM DETAIL CATEGORY 5 CABLING PROVIDED SHALL BE PROVIDED WITHOUT CONNECTORS ON THE ENDS AND WITH 10' -0" SLACK WHIPS AT EACH END FOR
OWNER'S USE (VENDOR WILL ULTIMATELY MAKE CONNECTIONS). IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE - CABLEING RUN THROUGHOUT STORE IN
THE PLENUM AREA SHALL BE SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE.
36.THE OWNER WILL FURNISH AND INSTALL A TRAFFIC COUNTER SYSTEM (SHOPPERTRAK - ORBIT SYSTEM) FOR THE SPACE. CONTRACTOR SHALL FURNISH AND INSTALL
CONDUITS WITH CATEGORY 5 CABLING FROM ONE LOCATION TO ANOTHER (VARIOUS PLACES) IN ALL LOCATIONS SHOWN ON THE DRAWINGS - EITHER IN PLAN OR IN THE
SCHEMATIC WIRING DIAGRAM DETAIL CABLE SHALL INSTALLED WITH 15' -0" TO 20' -0" SLACK AT EACH END. CATEGORY 5 CABLEING SHALL BE AS FOLLOWS: 4 PAIRS,
24 AWG, SOLID CONDUCTORS, TWISTED PAIRS, 7 X 32 TINNED COPPER, 12.5 Pf, 110 OHMS, CL2 PLENUM RATED - BERK -TEK CABLE #230247 (SOLID PLENUM) OR
BELDEN CABLE #1701A (BONDED, SOLID TWISTED PAIRS, PLENUM) OR EQUAL. IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE - CABLEING RUN
THROUGHOUT STORE IN THE PLENUM AREA SHALL BE AS MENTIONED BEFORE AND SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE.
37.GENERAL PURPOSE RECEPTACLES SHALL BE MOUNTED 18" ABOVE FINISHED FLOOR AS REQUIRED WITH THE ELECTRICAL FEEDS TO EACH RECEPTACLE INSTALLED DOWN IN
THE WALL. SEE ARCHITECTURAL DRAWINGS FOR ALL HEIGHTS, DIMENSIONS AND CONFIGURATIONS OF DEVICES NOT INDICATED ON THESE DRAWINGS. REFERENCE SAME
DRAWINGS FOR EQUIPMENT NOT IDENTIFIED.
38.VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES
AND FLANGES AS REQUIRED.
39.SUPPORT ALL FIXTURES WITH UNISTRUT AS REQUIRED.
40. NOT USED.
41.WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, AND ONE YEAR GUARANTEE, COMMENCING ON DATE OF
ACCEPTANCE BY THE TENANT.
42. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT.
43.PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE
PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES.
44.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL
45.ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED.
46.UPON COMPLETION OF WORK, PREPARE LIGHTING AND POWER PROJECT RECORD AS- BUILTS. PRESENT THE COMPLETED DRAWINGS TO THE OWNER. AS -BUILT DRAWINGS
SHALL INCLUDE ALL BRANCH CIRCUIT WORK, ANY PANELBOARD INFORMATION, FINAL SWITCHING, ETC.
47.ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE PROOFED TO THE SAME OR GREATER RATING THAN THAT OF THE ASSEMBLY. WHERE CONFLICT
OCCURS, NOTIFY THE ARCHITECT.
48.ALL FUSES 600 AMPERES OR LESS SHALL BE UL LISTED, CLASS RK1 OR J, LOW -PEAK, DUAL ELEMENT, TIME DELAY, 600 VOLT. ACCEPTABLE MANUFACTURES ARE
BUSSMAN, GOULD OR SHAWMUT.
49.VERIFY LOCAL CONDITIONS AT SITE.
50.COMPLY WITH ALL APPUCABLE CODES.
51.SECURE AND PAY FOR ALL REQUIRED PERMITS
52.THE TENANT MAY HIRE AN INDEPENDENT CONTRACTOR /INSPECTOR TO VERIFY THE PROPER INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM AS PER PLANS AND
SPECIFICATIONS. SHOULD THERE BE ANY DISCREPANCIES IN THE INSTALLATION, THE CONTRACTOR WILL BE NOTIFIED IN WRITING AND HAVE TEN (10) WORKING DAYS TO
RECTIFY THE ERRORS. IF THE TENANT DECIDES IT IS NECESSARY TO VERIFY THAT THE DEFICIENCIES HAVE BEEN CORRECTED BY MEANS OF A REINSPECTION, THE COST
OF A REINSPECTION (PLUS 10 %) WILL BE DEDUCTED FROM THE FINAL CONTRACT INVOICE.
EL09-- 07
REVIEWED FOR
COMPLIANCE WITH
NFPA70 -NEC
DEC 2 2 2009
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 1,12009
PERMIT CENTER
DATE: 11/1$/09
JOB NO: 09 - 066
DRAWN: STAFF
CHECKED: DP
W0- IL
cc cc
Q W can
00
Oz O
Cn W 03 O
cc °) d-
W Q
I- F
Z�
Q
(NW 0 2 CC
c^
I O 8 Q
cti
��O =�a
V,fI- Co I
jig')
L
CD
4-0
L
V
STORE NUMBER
%TBD
REVISIONS
'A'- ISSUE LANDLORD WORK UNDER
LANDLORD PERMIT
PATE 12/6/09
'I�' ISSUE
DATE
'C' -ISSUE
DATE
SHEET TITLE
ELECTRICAL
SPECIFICATIONS
SCALE
1/4' =1' - 0'
SHEET NUMBER
E5.0
U)
- 0
C
co
:CI
U)
0