Loading...
HomeMy WebLinkAboutPermit D08-001 - SEATAC LIGHTING & CONTROLS - STORAGE RACKSSEA TAC LIGHTING 4439 S 134 PL D08 -001 Parcel No.: 2613200086 Address: 4439 S 134 PL TUKW Suite No: Tenant: Name: SEATAC LIGHTING & CONTROLS Address: 4445 S 134 PL , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: FOSTORIA PARK ASSOC LLC Address: C/O ESM PROPERTIES INC , 15100 SE 38TH ST #792 98006 Phone: Contact Person: Name: MIKE SORENSON Address: 1100 SE 7 ST , RENTON WA 98057 Phone: 206 818 -4488 Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH STEET , RENTON, WA 98055 Phone: 206 255 -0500 Contractor License No: NORTHWH275JF DESCRIPTION OF WORK: INSTALLATION OF NEW AND USED PALLET RACKING. doc: IBC -10/06 Cityllif Tukwila • DEVELOPMENT PERMIT Value of Construction: $0.00 Fees Collected: $358.43 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: * *continued on next page ** Permit Number: D08 -001 Issue Date: 01/23/2008 Permit Expires On: 07/21/2008 Expiration Date: 10/09/2009 D08 -001 Printed: 01 -23 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: doc: IBC -10/06 City Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Date: c -) I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. am authorized to sign and obtain this development permit. Permit Number: DO8 - 001 Issue Date: 01/23/2008 Permit Expires On: 07/21/2008 Date: // c� Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -001 Printed: 01 -23 -2008 • City of Tukwila Parcel No.: 2613200086 Address: 4439 S 134 PL TUKW Suite No: Tenant: SEATAC LIGHTING & CONTROLS 1: ** *BUILDING DEPARTMENT CONDPI'fONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 -001 Status: ISSUED Applied Date: 01/02/2008 Issue Date: 01/23/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 12: Fire Department access and existing hydrants shall be constantly maintained during demolition and construction. 13: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (IFC 2302) 14: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire doc: Cond -10/06 D08 -001 Printed: 01 -23 -2008 Prevention Bureau. (NFPA 13) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Maintain minimum 6" longitudinal flue space between back -to -back racks. (NFPA 13- 12.3.1.14.1) 16: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 13- 12.3.1.13) 17: Pallets shall be stored no higher than 6 feet (1.8 m). Each pallet pile of no more than four stacks shall be separated from other pallet piles by at least 8 feet (1.4 m) of clear space or 25 feet (7.6 m) of commodity. Idle wood pallets shall not be stored in racks. (NFPA 13- 12.1.9.1.2) 18: Aisles in sprinklered buildings shall be a minimum of 44 inches (1118 mm) wide. Aisles shall be a minimum of 96 inches (2438 mm) wide in high -piled storage areas exceeding 2,500 square feet (232 m in area, that area accessible to the public and designated to contain high- hazard commodities. Aisles shall be a minimum of 96 inches (2438 mm) wide in areas accessible to the public where mechanical stocking methods are used. (IFC 2306.9.1.1) 19: The required aisle width shall extend from floor to ceiling. Rack structural supports and catwalks are allowed to cross aisles at a minimum height of 6 feet 8 inches (2032 mm) above the finished floor level, provided that such supports do not interfere with fire department hose stream trajectory. (IFC 2306.9.2) 20: Warehouses designed for high -piled stock shall establish and maintain aisleways of not less the 44 inches to provide access to all exits and fire department access doors. (IFC 2306.9.1.1) 21: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75 or less. (IFC 906.3) (NFPA 10, 3 -2.1) 22: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 23: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 24: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 25: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4) 26: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to doc: Cond -10/06 D08 -001 Printed: 01 -23 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 27: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 28: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and International Building Code. 29: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 30: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 31: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 32: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D08 -001 Printed: 01 -23 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us doc: Cond -10/06 D08 -001 Date: 3/08 ordinances governing or local laws regulating Printed: 01 -23 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htth :- ivwtn. ci.tukwila.tru.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: i f q / 5 5 • / 4. Tenant Name: 57,2„, L ��ti j ,� y eo,,4, /S , l"4.- L New Tenant: [8 Yes Property Owners Name: E pr , ' - ✓ ✓ fi •• s t 2» c Mailing Address: / 67049 Sa E . -.7r S/. -, 7 oelk„-ke_ _ 4 ''4 9e420 Ei State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 7/ ke. r•e113O.1 Day Telephone: PO6 -` S5 R - 41e 6 Mailing Address: l /00 S uV. ?' S J : (�� � -� �/,•f C eds 7 City State Zip / Fax Number: L O 5 = 3a2-61 Y-6 E -Mail Address: / c rei..SU C //nal S GENERAL CONTRACTOR INFORMATION — (Contractor Information for. Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: All r (A1- S f Mailing Address: (70 r) S41/. "7 S tke Soreosc, -) E -Mail Address: h'► S G f' -C? v S( ) -1 (c) i'l r S • (0 M Contractor Registration Number: We 'v'r) a7 5 3 E Contact Person: ARCHITECT. OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Per ail Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: MI 1)2 S!y,S t' . L+t / ;�fi c� Mailing Address: Lt./ I , Contact Person: 64/` 2 /VP) E -Mail Address: '' Q: Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. ' Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No, Project No. King Co Assessor's Tax No.: 2-( 1 9 , 1 )-1 / 7 - 0 11 /(0 Suite Number: City Slit✓, I,i C (For office use only) l.P h n tvilf 9RO.S' 7 City State Zip Day Telephone: ( rs f $' lilt f' Fax Number: 11..3 - 3D 6 9 y6, Expiration Date: /0 /C /acO el City Day Telephone: Fax Number: le C State City State Floor: _ 00( .. No Zip 4/ Zip Day Telephone: 8'g (R ' _S Fax Number: irc 2 Page 1 of 6 PLANNING DIVISION: BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 4 7, co() Existing Building Valuation: $ Scope of Work (please provide deta iled information): j� Sh /(a /.�,. e Ctsi e"/ L4.f ty/ p /('t- r ct cle/. neie h'4 It reldr d c ct��� �a �:, �✓� T4( /0 f e 1,-4 Grt/ C - r , r i9/e f+<_ ✓l �t� c 14 CG4 - l 't, e I C 1.J STr!'eGf Ii r GAL C �/e(�r- r � , Will there be new rack storage? ...Yes Provide All Building Areas in Square Footage Below Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11 " paper including quantities and Material Sa ety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:WpplicationsWorms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑.. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 Existing Interior Remodel ' Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor /0 / 5 - 0 6 7, D 00 2 Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 4 7, co() Existing Building Valuation: $ Scope of Work (please provide deta iled information): j� Sh /(a /.�,. e Ctsi e"/ L4.f ty/ p /('t- r ct cle/. neie h'4 It reldr d c ct��� �a �:, �✓� T4( /0 f e 1,-4 Grt/ C - r , r i9/e f+<_ ✓l �t� c 14 CG4 - l 't, e I C 1.J STr!'eGf Ii r GAL C �/e(�r- r � , Will there be new rack storage? ...Yes Provide All Building Areas in Square Footage Below Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11 " paper including quantities and Material Sa ety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:WpplicationsWorms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑.. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 1 Signature: PERMIT.APPLICATION.NOTE$ Applicable „to all :permits in. this application: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Print Name: ���Ji -2 �e`''�l�c rlih Day Telephone: a b” SP/0- `Z l g' Mailing Address: /((DLO S 4/ 7 S)'' Date Application Expires: Date Application Accepted: O I O2-1 Q:\Applications\Fonns- Applications On LineO -2006 - Permit Application.doc Revised: 9 -2006 bh City Date: / / /Q 6 _ ar Zip S tate ip Staff Initials: Page 6 of 6 Parcel No.: 2613200086 Permit Number: D08 -001 Address: 4439 S 134 PL TUKW Status: APPROVED Suite No: Applied Date: 01/02/2008 Applicant: SEATAC LIGHTING & CONTROLS Issue Date: Receipt No.: R08 -00204 Initials: WER Payment Date: 01/23/2008 11:01 AM User ID: 1655 Balance: $0.00 Payee: MICHAEL SORENSON TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description • • City of Tukwila BUILDING - NONRES STATE BUILDING SURCHARGE Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Payment Check 7062 219.00 Account Code Current Pmts 000/322.100 000/386.904 RECEIPT Amount 214.50 4.50 Total: $219.00 Payment Amount: $219.00 7567 01/23 9710 TOTAL 219.00 doc: Receiot -06 Printed: 01 -23 -2008 Receipt No.: R08 - 00004 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2613200086 Permit Number: D08 -001 Address: 4445 S 134 PL TUKW Status: PENDING Suite No: Applied Date: 01/02/2008 Applicant: SEA TAC LIGHTING & CONTROLS Issue Date: MICHAEL J. SORENSON TRANSACTION LIST: Type Method Description Amount Payment Check 7055 139.43 Account Code Current Pmts 000/345.830 139.43 Total: $139.43 • Payment Amount: $139.43 Payment Date: 01/02/2008 01:54 PM Balance: $219.00 6692 01/02 9710 TOTAL 139°43 doc: Receiot -06 Printed: 01 -02 -2008 j Project: "� . , 1� t ` /� Type of Inspec to A U ; rte-- f Add)res el X13 J del Date Called: /— Special Instructions: Date Wanted: 7l (o C G l� 'rrt p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36(7 INSPECTION NO. 0 $60.00 REINSPECTION FEE REQIyIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: e f A "1-- pt ems r 4,4 Date: 6 -2 / l ' 'O 'Receipt No.: . 'Da Approved per applicable codes. Corrections required prior to approval. `, • lA.7 1 . 6 :%r. ^�- =4<,. ,,. .fns COMMENTS: I A 11■-orb. t 4,,. ietkePP0.) ,s Addlgss�c7 ],/ (!) D ..36(S1 c 'Z . p..►‘c.i. , - C Special Instructions: �, / /if'� Date anted: - / 3 -d ' .v... S i t.<c.kc.. t c (7D 51Dc.k-AJai 0A4Pc'k\...f-a4AC: aiosivrwik 1 6 6 Qf 1T \ N 4 Projec� / A Type of�tls{�ecti� Addlgss�c7 ],/ ^ , n � � Date Called: Special Instructions: �, / /if'� Date anted: - / 3 -d p.m. Requester: INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION + 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. Inspector: 41 Date: ( . ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at• 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: `• • • 4,‘ COMMENTS: L .. 1 f ! �`�' ) ( i J )%i:- • ( ) � 4 /� d e w A ' - • �` �-( j,.•..1, /f (4f ,) 1 J J•i'D -ki of 1/ ra clki !'Xc P.a7• , v/ 7P r • A /L _ (--- ,...) # i 5 „el /---,' , P , . /'�✓ 1 /`_. P../ f,�I -, A-R (-vr .�}L M-; I , l 1 i De ,,4,71 I A f AT 1 ( g ti c,0 Date Wanted: I _...51.m.. p.m. Requester: f ik_l l J s , A--r- d �-� l A 6u _I e ' r c� �1,' I !,/ I �� J Cf t' f s A ; tom ; Ki i i Project: S” -/J .1)( L .. 1 f ! Type of Inspection: n' di r - S'7 cam( o f / � 'tI Adds...) ,�4.__ Date Called: Special Instructions: Date Wanted: I _...51.m.. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1E- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. Inspector: 1 Date: ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: . - COMMENTS: X o o.._s i r 3 A ( L:im'( - - ( T 3 U.)•t 7 \JMr) r' ele I.f i kI)i� ( 1 1 0 4 ? i;,,... e ,A ( 9 1 , - r e _ c _.,4 --- ; I iii ('-'._ _ , ...._(0.fs, .> AT( t- () J i ti l i Qe✓-■ : /\ fir /" t e A J 1 Lix`,T rb 11A c 1.,0'.( ,Q ,.( p AfT I,2 r. .V A t j': 1 ( k ) fr ) � � � , tA 1 \ Requester: INA) ) de.,!, -- ,,\ i TA *IQ) 1 09 L 1 Li .?\-j :)r 4.,,1 _, , • SP Saec.A ,,, 5 .-t , ,),,- s n c o f- f . �. r (' / ��'n S' (' . T.: Cr '- ; 1 ( )L � , . r m6 i_.A fl • t i -, r Probe „. L /� Type of Inspection: r i Address:1. 5 7 3 YQ � Date Called ...4 pecialll Instructions: 00 Par kir,' e � 'J • # ) k( S f • ,, l eiS 1 A � "'f ^ G / Date Wanted: ?�— DP a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit Da / INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspect r: 1 0 . 1 Date: I- Z ti v 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: .•t' a.. ... .. _ . • . _ A _ L v. ...e .. r . ..._ • - ! ..! s1e a'.ht 44,41.4' Project: S ,, ( c. ..„ 0 .„,.. Type f Inspection: C /"--- Pre-Fire: Permits: Address: Suite #: 5. i '..-- t- ,' Contact Person: s.7, lv le t:: 2, ( if Special Instructions: Phone No.: Needs Shift Inspection: A ; ( ,_. Sprinklers: )/ Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT - 17.) (:)• (;c:) PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Approved per applicable codes. COMMENTS: tk-L A IK/ - C tR-- 1::X- -7- 1"-" *!..:› MA oc-: AP get 1 Corrections required prior to approval. Date: 4,1? / Cr( Hrs.: Inspector: k I, r $86.00 REINSPECTION FEE REQUIRED. You will receive an invoice from th9 City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 \O Project: Se - L , 6,t-4 -n 14 6 Type of Inspection: Lr. Address: t1439 S , Suite #: 13` "PL Contact Person: Job,s. 1a0.42., Special Instructions: Permits: Phone No.: 200. 58. Needs Shift Inspection: Sprinklers: Fire Alarm: , Hood & Duct: Monitor: ,Pre-Fire: Permits: Occupancy Type: - 2_ INSPECTION NUMBER CITY OF TUKWILA FIRE. DEPARTMENT Approved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit 1/13/06 "'Dam - ot� • PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Corrections required prior to approval. COMMENTS: X 'T. -OK_ 3 IC._ — ra ST.C' Co L_ t) A•. NS Pt:714 DiNet9 eL A deli EW t 4, Inspector: Date: Li j /d $ �/ Hrs.: I $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: Ste 1 Wit. ,A 6 Type of Inspection: Fire Alarm: Hood & Duct: Monitor: Address: Li Li 'S S . t PL Suite #: Contact Person: plitv.z d ie 6` Occupancy Type: - N __ Special Instructions: Phone No:: gig - 1 1 4 406 J]J ! 06* fJ - 500 Needs Shift Ins pection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: t INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIREDEPARTMENT 'D08- 001 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Corrections required prior to approval. COMMENTS: e i_ani M 1aa�67. Aeo7r z b(g .' 0-,e04 I . } R Inspector: IALL11 / S i L Date: 1/ I , Hrs.. . I n • $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 NORTHWEST H A N D L I N G S Y S T EI M s, I N C. The Material Handling Experts ATTENTION FIRE AND BUILDING DEPARTMENTS RACK INFORMATION SUPPLEMENT SITE ADDRESS: 4445 S. 134 PL TENANT NAME: Sea Tac Lighting Et Controls, LLC DATE: January 2, 2008 APPLICANT: Mike Sorenson / (206) 818 -4488 1. Load application and rack configuration drawings attached. 3. Stamped engineering calculations attached. ALE COPY 1100 SW 7th St Renton, WA 98057 (425) 255 -0500 ph (425) 228 -6946 fax REVIEWED FOR CODE COMPLIANCL PPROVED JAN 2 ;). 2.003 ity Of Tuk'vi;a 2. Attached plans detail the rack locations, dimensions, and specifications. Attached plans detail the building /ceiling configuration. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored: Commercial lighting fixtures and components. Recessed lighting canisters consisting of 90% steel and aluminum and 10% plastic in lenses, trim, and moldings. 6. Sprinkler System Information: Wet system. Static psi: 150. Residual psi: 125 7. Smoke and heat vents: Not required for square footage of racking (under 12,000 square feet). 8. Building egress and exits indicated on attached drawings. CITY LIV JAN 0 2 2008 PE1MIT CENTER BY G. OHANIAN DATE 12 -2C -07 SUBJECT SEA TAC LIGHTIN G & CONTROLS 4445 SO. 134th PLACE TUKWILA, WA. 98165 3/8 "0 BOLT SAFETr LOCK — (1000 # CAPACITY) FILE COPY Permit No. Pier review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By Date: - 3 7t9 R City of Tukwila BUILDING DIVISION Z0 /Z0 39dd BAdK DENI(IN & ENC>}INEERIN( d0. 412 WET BROADWAY, OWTB #204 LENDALB, OA. 91204 TEL:(810)240 -3810 FAX :(818)240 -3813 Cc.:;... C... . BEAM CONNECTION N9ISBO >13Vd RECEIVED CITY OF TLUK\ft' _A JAN 30 "=.6 %. iuvu I ukNTER 3/8 "0 BOLT SAFETY LOCK 7/16"0 RIVET ASTM A576 -90B SHEET NO. 4 JOB NO RD - 12848 ice'+ )•t ei�Tr1 <: ;:'iii 'c j ;:.• ''i" :r a 'nclude addltlonul : I ri r ` n..;. 'Pr.?s RE VISION N�a� pOOO( ETBE- 0172 -8T8 EZ :50 8002/6Z/T0 SeaTac Lighting & Controls 4439 S 134th Place Tukwila, WA 98188 Construction Adhesive from top to Bottom. Typical on all four sides attaching 5/8" Type X gyp board to post. Sheet Wrap 1 hr Fire Rating Detail Permit # D08 -001 Detail Required Inspection #1 NOT TO SCALE REVISI C RECEIVED CITY OF TUKWILA JAN 30ZO8 1 20 W PLHMIT CLI IER 5/8" Type X gyp board completely wrap 5 1/2" square steel post. Level 1 tape per industry standards all seams and corners. -. r ■ ®■ ■ mom ■LA! t ■ sums I ■ :11111111Un ■ mum mismilmow ■ ■ramoma■■as■alimm nl ■■P■■ E aui4U 111MM ■■■■ eis ■■■ m u ■■ ■ krl P ill C �■ wi ii i ■■ ■■ • --. _ i as ampununcininimproun Na -- =IA N . iP /i� 116110M l il 114131111111111 ®l i m itii�� H■ ■0ii;awiimif ■■ ii1 ■l vow �llir.sor i%0� A1<1 IIMiP `i®�i■s •1= 1111 suss■■ �il ■s/, U 'I115s.a MUM ■ us. u. isri`M . s ■■ ■■i mom ■■■■' •i ssuS1 u � a 1s•.Iu sumsmum m:_ •1ss... ■■■s■i MI MO ssss■■U /■•■ 11N■ ■s III 11111 I■■■■■1 111 NM ■■ ■ 1III1 1IIIIII�H! 111 ■1� II Ia� IHhI 1I�nibm it !t■■■ N■■■i1i ■ ■■� ■ ■ ■ ■ ■�iNm i■N ■ us b us �■suuu m ii■ ■s 1 aiui■11lu1.■se ■ ■ 111111111111111111111111111111 s ■■ ■ ■NS■ %■■■i N - M: - amii1uuiusm :m1C- m •11x1• ![a al.■■, i■ ■sisi.�Ni ■ 11N ■U' ®u■, 1u®■•.■■ s■ ■s ■ ti i mums ■ 1■■■ ■ • mum ii s■/ l ■■sNlis■sWWI � :i i_ :� ■N■ u_n' ■ MU ■ ■ 11 11111111111111111111 m , 1 ;■■ MR ■s ■ ini , ! • ■1.1■■■ ■ iin :n :: n - .I : l,1■ ■s ■u ■■sN1l ■sl 111111111 111111111111111111 11 ■EM ■■■Nils■■■ ■■ ■■ ■■ ■ ■ i ■■■ • 1i ■ ■ ■ UM ii�� 11N■s ■ i■■ Kai ■ /.�iN ■s).■. as ■ il. '1 ■■ msm iuP ! ■■ II ua u,, SeaTac Lighting & Controls 4439 S 134th Place Tukwila, WA 98188 Construction Adhesive from top to Bottom. Typical on all four sides attaching 5/8" Type X gyp board to post. Sheet Wrap 1 hr Fire Rating Detail Permit # D08 -001 Detail Required Inspection #1 NOT TO SCALE REVISI C RECEIVED CITY OF TUKWILA JAN 30ZO8 1 20 W PLHMIT CLI IER 5/8" Type X gyp board completely wrap 5 1/2" square steel post. Level 1 tape per industry standards all seams and corners. -. r gy G. OHANIAN DATE. 12-20 -07 SUBJECT STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: SEA TAC LIGHTING & CONTROLS 4445 SO. 134th PLACE TUKWILA, WA. 98168 PER IBC 2006 EDITION STORAGE RACKS CAPACITY: 3000 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -12848 RAdK DENI(4N & ENOINEERINGI do. 412 WRIIT BROADWAY, 6IUITE #204 LENDALE, CIA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 FILE COPY PP Milt NOn EXPIRES 12 -26 -09 ' R'�E � ® NCB. CODE. COMPLIANCE JAN 2 '- 2N`.A r , .t SHEET NO. 1 JOB NO. RD -1 2848 RECEIVED CITY OF TUKWILA JAN 0 2 2008 PENMIT CENTER BY G. OHANIAN RACK DESIGN & ENGINEERING CO. DATE . 12 -20 -07 412 WEST BROADWAY, SUITE #204 GLENDALE, dA. 91204 SUBJECT TEL:(818)240 -3810 FAX:(818)240 -3813 s N c• (O SEISMIC DESIGN V= Sdsxl x W Rx 1 .4 WORKING STRESS LOAD PER COLUMN LL= 2 c K =3 K W=.3 .L 2 L.L: 2.3 K V —_ 1x2.3 — 27K LONGIT. 6X1.4 • V TRANS. TRANS. 41 K 108" 1 If If 1 ar— BEAM M= 108 "x1.8 = 24 "K 8 S R = 30 "K = . 8 <.82 FRONT VIEW A__ 5xWxL3 =.39 "< 100 = .56" 384x1 xE 180 1 =1 R =6 MOM. CONN. R =4 BRACED Sds =1 W =D.L.+ 2/3 L.L. IBC 2006 ASCE 7 SEC. 15.5.3 CO Co 44" 44" a-- ar- 3000 #/ LEVEL +25% IMPACT LOAD 1800 #/ BEAM I x =1.84 5 =.82 F Y= 50 KSI. LONGIT. SEISMIC SIDE VIEW .27 K 9 "K CD CD SHEET NO.. 2 .. ,..... JOB NO.. RD -12848 44" a— } BY G. G HANIAN DATE. 12 -20 -07 SUBJECT COLUMN ANALYSIS 3 x— — t =.07" (� f M u \ COMBINED STRESS RATIO P M — 10 +18 = . 7 <1.33 a ax Fy =50 Ksi A =.6 S =.6 r =1.2 r =1.1 BASE PLATE ANCH. TENSION = 9—(2.3x3") = 35 K ANCHOR SHEAR = • 21 = 21 K (2) -1/2 "9 HILTI KWIK BOLT -3 ANCHORS ESR -1385 OR APPROVED EQUAL. DESIGNED FOR 1/2 STRESS. (NO SPECIAL INSPECTION REQ'D) MOMENT AT BEAM CONNECTION 7/16 "95 RIVET A =.1 Fy = 79 KSI Va = .1x79x.4 3 Ma = 3Kx4 "x1.33 = 16 " 3 PIN CONN. CONN. RACK DESIGN & ENGINEERING CO. 412 WENT BROADWAY, SUITE #204 dLENDALE, CA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 KI _ 60x1.7 _ 85 rx 1.2 KI 44 — T_ y — • Max =S • Fb= 18 " 7 "K Fe= ( K i E2 =40 Tx F =F (1— I )= 34 Ksi P =F xA= 20 K P — Pn — 10 K a — 1.92 — 23 SHEET NO. 3 JOB NO. RD -12848 7.75 "x5 "x3/8" BASE PL. BY G. OHANIAN RACK DESIGN & ENGINEERING CO. DATE . 12 -20 -07 412 WEST BROADWAY, fi1UITE #204 SUBJECT OLENDALE, CA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 OVERTURNING M .41 K x2x124 "x.5x1.15 =58 "K MR = 2.3 K x44" = 101 "K NO UPLIFT LOAD TO DIAGONAL P = .41 Kx2x K 44 = 1 F y =50 KSI A =.31 r =.48 Q =.74 L= 52" CHECK WELDS CHECK SLAB 2300 =2 3 0' 1000 F a = 12.3 KSI P 3.8K 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K 2.3x144=331 .3x 144 =331 0 " - \/ - 1 =18" M= (j1 ) 2 x 12 = 1260 "# S= 12x5 = 50 6 1260 = 25 <1.6 2500 =80 50 TOP LEVEL LOADING M =.21 Kx2x124 "= 52 " K MR =1.3 Kx44"= 57 "K BOTH SIDES NP 2300 # SHEET NO 4 JOB NO. RD -12848 5" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL 06 -05 -2008 MIKE SORENSON 1100 SE 7 ST RENTON WA 98057 RE: Permit No. D08 -001 4439 S 134 PL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/29/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Jeer Marshall, Permit Technician APP xc: Permit File No. D08 -001 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 4 January 7, 2008 Mike Sorenson 1100 SE 7 St Renton WA 98057 RE: Letter of Incomplete Application # 1 Development Permit Application D08 -001 Sea Tac Lighting & Controls — 4445 S 134 P1 Dear Mr. Sorenson, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 2, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the following comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, fer M . rshall P it Technician Enclosures File: D08 -001 • city of Tukwila Department of Community Development Jack Pace, Director P:\Permit Center\Incomplete Letters \2008\D08 -001 Incomplete Ltr #1.DOC jem • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 I Determination of Completeness Memo Date: January 3, 2008 Project Name: SeaTac Lighting & Controls Permit #: D08 -001 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The address provided on the permit application is incorrect. After clarification of the address which included a site investigation, we discovered other work in progress without any permits. In addition, the plan provided indicates new tenant improvements. Before this permit is to be approved a tenant improvement permit shall be required which shall also identify egress paths and other egress components for the offices and warehouse. Lighted emergency egress pathways shall also be identified on the rack permit plan. 2. Another concern which pertains to both the rack and tenant improvement permits is where the offices are shown exiting through the warehouse. Egress shall not pass through storage rooms (warehouse). Show on the plans provisions for an exit passage way enclosure where offices shall not egress through the storage area. (IBC 1014.2 & 1020.3) Please note: rack plans shall be consistent with any revisions to the tenant improvement plans. Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. ACTIVITY NUMBER: D08 -001 DATE: 01 -30 -08 PROJECT NAME: SEA TAC LIGHTING & CONTROLS SITE ADDRESS: 441 S 134 PL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued DEPARTMENTS: Buil sion Public Works Complete Comments: APPROVALS O CORRECTIONS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route V Structural Review Required REVIEWER'S INITIALS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Permit Coordinator DUE DATE: 01-31-08 No further Review Required DATE: DUE DATE: 02-28-08 Not Approved (attach comments) n DATE: Planning Division Not Applicable n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -001 DATE: 01 -18 -08 PROJECT NAME: SEA TAC LIGHTING & CONTROLS SITE ADDRESS: 4445 S 134 PL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS: But ng D'ivision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete n Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: n Planning Division Permit Coordinator DUE DATE: 01 -22 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n No further Review Required DATE: DATE: n DUE DATE: 02-19-08 Not Approved (attach comments) n Permit Center Use Only • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Buildig visi Public Works Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 *EMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -001 DATE: 01 -02 -08 PROJECT NAME: SEA TAC LIGHTING & CONTROLS SITE ADDRESS: 4445 S 134 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued X12- M C' Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Th rs.) Complete Ti Incomplete TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: n DATE: DATE: Planning Division ❑ Permit Coordinator Not Applicable No further Review Required n DUE DATE: 01 -03-08 Permit Center Use Only INCOMPLETE LETTER MAILED: (oi l 01 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initial n DUE DATE: 01-31-08 Approved Ti Approved with Conditions Ti Not Approved (attach comments) Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 a(( &oIn ` 3 --1 Summary of Revision: Summary of Revision: 7 f l,t, U 12 (40. F-jR(,T 11(r Received by: 1 14ev 01\A e )1'Eel, f, un,M u w kiree c a.lv Received by: yr7i k REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: C 1 tk-tvn 1 V PERMIT NO: • O t? O( SITE ADDRESS: 1dH Gj ( Q(, ORIGINAL ISSUE DATE: 0I , p$ REVISION LOG (please print) (please. print) (please print) (please print) (please print) I s© s v�Pvrt co ItAm r. s City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: i / Plan Check/Permit Number: DOg / ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: i 1 Ct C- 4- t q�► °l �c�n 7'�r ( S Project Address: 1 1935 - 5,1, / 3 %' tth Pio C-e- Contact Person: "-like_ S0 - - - 4-9r) Phone Number: c2 26 S' - V 4'#? Summary of Revision: a#6 zhe / -'-tS -/ .. c/ t V +SQ z � a r ,iCtfl rJ 4 -f 'rev;c l A3- r I 4 ( h tAn Tra7'2 4 / / o S, �/ oc r cfre. r^ ct Steven M. Mullet, Mayor Steve Lancaster, Director I EC El1/Eb JAN 30 2008 rd c) Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision \applications \forms- applications on line \revision submittal Created: 8 -13 -2004 Revised: Received at the City of Tukwila Permit Center by: Entered in Permits Plus on Dj t 01 " 1 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D08 -001 • Response to Incomplete Letter # 1 AE ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued 'JAN .18 2008 ❑ Revision requested by a City Building Inspector or Plans Examiner jEPA,frr CarTEA Project Name: Sea Tac Lighting & Controls Project Address: 4445 S 134 P1 Contact Person: 1 `'le Sr, r o v S a ,. Summary of Revision: Dr-6 5 . 3 A re « —f { c. f ; (�p,^') fC r{ s f r ek.4 /l s as u -'-- /l e4 s /4// 12 r SJ o(ThG. f at 0, -A,. . s7 e.)...• d ! r r� (� eik 7' / -r r .e. ( Che /9n / ""` Q TT4 G1i dry i . . Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: iWM, Entered in Permits Plus on () ( Vi j \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Phone Number: Steven M Mullet, Mayor Steve Lancaster, Director -2(2 L(t 88 License Information License NORTHWH275J1: Licensee Name NORTH WEST HANDLING SYS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600051641 Ind. Ins. Account Id 32999900 Business Type CORPORATION Address 1 1100 SW 7TH ST Address 2 City RENTON County KING State WA Zip 980552939 Phone 4252550500 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/6/1973 Expiration Date 10/9/2009 Suspend Date Separation Date Parent Company Previous License Next License NORTHHS963ND Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #6 TRAVS 81S103354822BCM 10/01/2001 Until Cancelled 01/01/1980 $12,000.00 10/09/2001 Business Owner Information Name Role Effective Date Expiration Date FRANCK, JAMES J 01/01/1980 THOMAS, KEVIN A 01/01/1980 KOSTY, CLARK R 01/01/1980 Look Up a Contractor, Electean or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= NORTHWH275JF 01/23/2008 C 54' -11' 54' -7' 12' 7'- 12'-0" 6' -08' 24' 10.-0" 24' 2'-0" 2' 8'-8" 24' 3'4" SCALE: 1/8" = 1' -0" 8'-0" A EXISTING R STROOMS (3) UPGRADE OF FINISHES CONFORM TO ACCESSIBILITY REQUIREMENTS - SEE SHEET A3 PLAN VIEW 24'-2' EXISTING KITCHEN UPGRADE FIXTURES 23' -10' EXISTING UNDER PREVIOUS PERMIT A 24' 4y 20' DEMOLISH EXISTING NON STRUCTURAL PARTITIONS AND SUSPENDED CEILING ASSEMBLY IN EXISTING OFFICE EXISTING 3'0" x 6'8" (PAIR) DOORS EXIT SIGNAGE SEE SHEET E2 EXISTING BUILDING SHELL NO WORK alcjet t:* Iv scope of Tukl.Mi B £s� ems"+ NO qr. v siors w111 rquire a new pian subnIttri am m2y ^ci= de additional pIan review fees j 1016.2 CORRIDOR WIDTH: GROUP S -2: 36 INCHES WITH AN OCCUPANT CAPACITY OF 50 OR LESS. in summary: According to sections 1014.1 and 1018.2, if the warehouse were less than 100' in length, only one exit door would be required. However, because the warehouse is longer than 100', both existing doors will be required as egress doors. The formula for the required separation distance between two exit doors is described in Section 1014.2 above. Fortunately, one third of the longest diagonal distance in the warehouse is approx. 60 feet. The two doors in the warehouse are 68' -8" apart, so they meet that requirement. The maximum exit access travel distance is 400 feet. The maximum common path of egress is 100 feet. This means the overall length of any path of egress must be less than 400 feet, and within that path, only 100 feet can be shared by more than one (merging) path. (For example, each path of egress between the racking will meet at the end of the racking, then merge and continue to one of the two exit doors. The distance from where the paths merge to the exit doors must be less than 100 feet.) M1 , WAREHOUSE 9148 SF GROUP S-2 OCCUPANCY - NON-HAZARDOUS STORAGE (PER SECTION 311) 1004A DESIGN OCCUPANT LOAD: PER TABLE 1004.1.2: MAX FLOOR AREA PER OCCUPANT FOR WAREHOUSE: 500 GROSS SF 9148 SF / 500 =18 OCCUPANTS 10133 COMMON PATH OF EGRESS TRAVEL: LENGTH OF COMMON PATH OF EGRESS TRAVEL SHALL NOT BE MORE THAN 100 FEET (OCCUPANCY S WITH SPRINKERS) 1014.1 EXIT DOORWAYS REQUIRED: GROUP S SPACES WITH ONE MEANS OF EGRESS HAVE A MAX. OCCUPANT LOAD OF 30. DESIGN OCCUPANT LOAD IS 18, THEREFORE ONLY ONE EXIT DOORWAY REQUIRED. 1014.2 EXIT OR EXIT ACCESS DOORWAY ARRANGEMENT: EXCEPTION 2: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM THE SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOT BE LESS THAN ONE -THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. 1015 EXIT ACCESS TRAVEL DISTANCE: 400 FEET MAX. (GROUP S w/ SPRINKLERS) 1018.2 BUILDINGS WITH ONE EXIT: GROUP S MAX. HEIGHT : 1 -STORY MAX. OCCUPANTS / TRAVEL DISTANCE: 30 / 100 FEET NOTES FILE .. . PY Permit Plan review approval le subject to emirs and wisdom Approval of comb :4bn documents does not audfodze the violation of any adopted code or ordinaries. Receipt of approved Field Copy and condlorle is acknowledged: BY Date City of Tukwila BUILDING DIVISION CITY OF RECEIVED JAN 1 8 2008 PERM! I CENTER SHEET NUMBER 1 DRAWING NUMBER w J Q N U- a w z w 0 FL 0 a r_i w U a a N vi z z a 4 W C] U w w r w a. 0 O O d X cn Ui I- IL J - 2 a `" O Z C,) z 0 cn w N v , Lf) w IC) w 8 0 cr co 0 V) a 1 0 o� ca: H N p 5 � ° [Y Cl, 4 D -3 I LUMINAIRE SCHEDULE Date Jan 17 2008 Scale 1/16" = 1' Drawing No. W050- 07 -wh -eg 1 of 1 Symbol Label Qty Catalog Number Description Lamp File Lumens LLF Watts A 19 C 1 96 GENERAL PURPOSE CHANNEL, 8' 1 LAMP T12 SLIMLINE (1) T12F96 6200 LUMEN LAMP 118019.1ES 1100 1.00 100 EXIT 2 L5049.IES 1 1.00 3 Designer Willie Baxter Date Jan 17 2008 Scale 1/16" = 1' Drawing No. W050- 07 -wh -eg 1 of 1 STATISTICS Description Calc Zone #2 Symbol Avg X Calculated values include direct and interreflected components. 1.13fc Max Min This layout is offered in response to the criteria and conditions established by the customer requesting design assistance, and as contained in the output summary. Accepted industry design practices and methods have been employed in con- junction with a recognized software program. This layout represents our best interpretation of the desired results but, as actual field conditions may vary, it is not intended to be a guarantee of fixture performance nor absolute measured statistics. Max/Min Avg /Min 1.54 fc 0.37 fc 4.2:1 3.1:1 f. / xio x 0.30.42 + 1.03.01.03 444XIUH (i � x.318.45 /X1 +1.1I .1 -0.10 + 0.49.40.58.613 70.80.8t.9 .9 8.9`0.9 +1.1 '6.1 .16 '0.46.41.50.0.79.78.813.9 .O + 4.0 + 5.0 - 9.0 - 9 .0 + 6.01. + 3.01.11 .1 + 1.2 + 1 .2 + 1.21 '1;.01.14.11.11.11.11 .13.1 1.24.24.24.24.21.18.11.03.9 .813.8'8.70.7b.6t1.613.6 .50.58.56.5'8.50.5'9.50.4 1.11.15 1.36.3 .3 '2.3 '2.31.3x.23.23.2'9.29.20.3 - 6 .36.3 1.29.24.2'5.21.11.00.9 .89.8 7 5'0.50.4 + 1.14.19 + 1.3.3 + 6.3 + 6.3.33.3 + 4.3.3.3.3.3.33.3 + 4.3 + 4.33.3 + 1.2 1 8.2 .0.9 .8�8.8�D. .1 7'0. 7 X1.68. 6 60.6 + 1.13.23 + 1.3 - 4.40 +1.33.3 I! + 1.21.26 + 1.2.44 +1.3 r: J +� .24.29 + 1. 4 + 6.47 + 1.4'9.3 ` • { +1.218.31 _ + 1.4$.49 + 1.4' 1.4 _._ ± 1.23.33 7) ,. + 1.50.51 + 1.4.4 + 1.3$.34 - +1.5.5523 +1.43.4 + 1.3 + 1.34 r t + 1.5 1 ..r. y � +1.43.4 r 1_ + 1.3 + 1.35 - + 1.53.54 ' t + 1.4'3.4 I.3 + 1.35 + 1.53.54 - + 1.4'3.49 .:1 ci..: + . 3 +1.35 c :r . + 1.5`3.54 (a -, r . r + 1.4 ' $ 3 - _ - - _. :3 3 1 1 . 1.5`4.54 - { .4'.5 ----r +1 .36 35 t r z. � r 1.3-'2.36 �.r r 1.54.54 .r 11.31.3 3 . + , 1.5454 1.3.33 .t 1.32.36 1.5 1.36.32 t +1.32.36 , > r r , r + 1.34.32 Plan View t. 1.54.54 +1.31.36 - - { 1.54.54 . + 1.33.32 r +1.3 +1.35 - : - r +1.53.53 r i +1.3 +4.3 + 1.31.35 +1.5.52 . . +1.3.3 :a + .3 - 0 .34 + 1.51.51 + 1.3.2 (a:' 9x1 ( . ) �i l t) 1.) .30.34 1.0.50 +1.3 +1.2 .2 .33 ` = + 1.49 49 f +1 ' .2t +1 2 + 8 32 f +1.43.48 t +1 2fi 2` +1.2 + 1.4`L47 * 1 2 + 6 2 t + 1.2$.31 t: ::) (:? +1.43.45 t )) + 1.2 0, 2 + 1.2 1 6.29 + 1.43.43 _ ' + 1.20.1 (7 I + 1.2 + 4.28 � + 1.4 + 1.41 ` t : t +1.1'1.1 +1.218.26 t +1.33.3 + 1.1 1 $.0 1.21.25 + 1.$x.36 + 1.0.0 �1_ +1.11.22 (r� + + c z) r (, +I li ..1 1.34.33 .0 + 1.1 .20 - I ' + 1.3 + 1.30 1 0.9 .9 (x>> _ +1.13.18 . _� + 1.2'6.27 i +0.9.8 ,- ' , , _ 2 ‘‘; + 1.11.15 +1.23.24 -- - _ 0.8 c. f + 1.03.12 +1.23.19 r + 0.8!.79 (7. (r) 1. , X , . + 1j .03.07 +1.1 +6.15 + 1.0 - 0.03 f a . +1.1 + 1.10 .-- r +.9+8.98 r r '9.91).92 +1 . 03 .04 i + 0 . 9 . 98 0.813 .8 0.813.811 8 � . 9� .913 .9� D . 9 + m . 9 � .9 . 9 � .9'9 . 9 2 + 0.713.84. 813. M. 8 0 .8 + 0.88.813.86.8 t 8.80.80.8 1 0.85 /IX10 44X11..M X1,0 t - t F XII Scale 1/16" = 1' RECEIVED CITY OF TUKWILA JAN 1 8 2008 PEiMII CENTER ( rr7 REVIEWED FOR. CODE COMPLIANCE APPRC u INCOMPLETE LTR# � -oo C) 0 co F- co a) \ BOTH \-t 1----;=-T- — ., ..........., • ... 1 3/4" Al -...,.. . . --of It It g • 1-1 .....k r.;:t 9/5 l .1 SIDES TYP. 1/8 V1.5" 11/2" fr3 'IlAll s \' \. % , 0 / 1 . , ., . t=0.07" \ B _ r- ' 2 3/4" • • TYP ---- .111111/.4 1/8 V 7 2 -...c..:1 — I ! I 1 1– : I 1 j I / / El r., . - i 1/4"0 SAFETY LOCK (1000 # CAPACITY) TIT 3" - A. I gI0 1 In8n1 iv ul rcE, \ t=.07" SEC. A-A . , MP 45 2 / TYP 'in t=.07" . 7/16"0 ASTM I t lie L L___ to t3/8" ' • ... . . ...t. . . 'h. : • • ' .. . . .... ., . .., . " . . • ' - • ......• --' !'. ' , ''... . . . 4 • • " • • Ca , I: .., . .. ....... to 1 8 PIF 1.5" ) 616. I __\/\_± . -- . A i • . .. • o 1 • . I 4° I 2 c.i •,. \ 6" • er • (2)-1/2"0 3 1/2" ,i• . .• .• • • • • • . . \ 1 I MIN ID 1 I 9 1 7 3/4" r SEC. B-B ANCHOR BOLTS PER BASE PLATE EMB., (SEE NOTE NO. 4) - �11 RIVET A354-79 TH'K=3/16" BRACING DETAIL ,..i CONNECTION ,, (4 . BASE PLATE DETAIL , , j 4_, q3d 3/ ----' -.._... • p,51 ..... ..... ... 1 ..... ...-- . 0 01-, 30/ T5 - ••,.. TYP .,,, 1111111111111111.III :: a ....-- ---- ., 0 ® a t3- ... I ...-- ..- ..-,... ,.... -... --.....__.--- 1/4% It 4. 01 „. ■`-- _ . . , . , . , . 1 -_-_,_ ' REViEW CODE COMPLIA; —, ..,,_ AppR JAN • I 7 ' 1 ' , • ROW SPACER (4 GENERAL CONFIGURATION . - 108" 44 44" 44" . NOTES:. 1—DESIGN OF STEEL AND CALCULATIONS OF THE IBC 2006 2—STEEL FOR ALL SHAPES 3—ALL WELDED CONSTRUCTION (E70XX ELECTRODES) 4—ALL ANCHORS HILTI (NO SPECIAL INSPECTION 5—CONCRETE SLAB 5" 6—STORAGE RACK CAPACITY 7—ALL RACK INSTALLATIONS A PERMANENT PLAQUE SHOWING THE MAXIMUM 8—STORAGE RACKS SHALL VERTICAL OF 1/2" < , STORAGE RACKS AS SHOWN BY THESE DRAWINGS ARE IN COMPLIANCE WITH THE REQUIREMENTS EDITION FY=50 KSI. ASTM A570-85 GR.50 (EXCEPT AS NOTED) IN THE SHOP OF THE APPROVED FABRICATOR #777 KWIK BOLT-3 ESR —1385 OR APPROVED EQUAL REQUIRED) THICK 2000 PSI. SOIL BEARING CAPACITY 1000 PSF 3000 #/ LEVEL SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS EACH NOT LESS THAN 50 SQUARE INCHES IN AREA PERMISSIBLE UNIT LOAD OF 3000 #/ LEVEL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE IN 1O'—O" OF HEIGHT RECEIVED c 1 : Ai i NI v i o i 0 : 2 - r G t. FE E l t_ A 1 r, s,, 1 g b„----. ■ , . 2 CV cri ,- °D s, _ _ N _ aj a %l el' 2 ;4- d- tt _ - ! NI A- CO \\\\‘‘ / \ 2/ r----- - 1■1 co , 1 II i. '4- -4- * ---- 2 \ 1\ 2 \ A .:. CV co I Jr $ N - -:,- ,.._ co. / // // REV. DATE REV REVISION - 412 CK DESIGN AND ENG I WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 - 414:.f !•-:- „ '', SCALE: NONE DRAWN BY: A.KH. . P DATE: 12-20-07 PROJECT: SEA TAC LIGHTING 4445 S. 134th PLACE, TUKWILA WA. FRONT VIEW SIDE VIEW STORAGE RACK DETAILS JOB NO. RD-12848 SHEET NO. EXPIRES 12-26-09