Loading...
HomeMy WebLinkAboutPermit D08-037 - STEPPING STONE VENTURES #28 - MOBILE HOMESTEPPING STONE VENTURES 14005 42 AV S #28 EXPIRED 07 -29 -08 D08 -037 Parcel No.: 1523049008 Address: 14005 42 AV S TUKW Suite No: Tenant: Name: STEPPING STONE VENTURES #28 Address: 14005 42 AV S , TUKWILA WA Owner: Name: STEPPING STONE VENTURES L L Address: 20303 10TH AVE W , LYNNWOOD WA 98036 Phone: Contact Person: Name: ERIN O'LEARY Address: 20303 10 AV W , LYNNWOOD WA 98036 Phone: 206 484 -3840 Contractor: Name: OWNER AFFIDAVIT - ERIN O'LEARY Address: Phone: Contractor License No: Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 CitAbf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us $1,300.00 DEVELOPMENT PERMIT DESCRIPTION OF WORK: INSTALL AND SET UP MOBILE HOME (RENEWAL OF EXPIRED PERMIT D06 -108). * *continued on next page ** Permit Number: D08 - 037 Issue Date: 01/31/2008 Permit Expires On: 07/29/2008 Expiration Date: Fees Collected: $65.70 International Building Code Edition: 2006 Occupancy per IBC: 0022 D08 -037 Printed: 01 -31 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: Signature: Print Name: c31 doc: IBC -10/06 1 City Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us N Permit Number: D08 - 037 Issue Date: 01/31/2008 Permit Expires On: 07/29/2008 Date: DIl I hereby certify that I have read and xa ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform e of work. I am authorized to sign and obtain this development permit. Date: This permit shall become null and void if the wotk is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -037 Printed: 01 -31 -2008 Parcel No.: 1523049008 Address: 14005 42 AV S TUKW Suite No: Tenant: STEPPING STONE VENTURES #28 1: ** *BUILDING DEPARTMENT COND1TiONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 - 037 Status: ISSUED Applied Date: 01/18/2008 Issue Date: 01/31/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All wood to remain in placed concrete shall be treated wood. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 D08 -037 Printed: 01 -31 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: 2-.---C Print Name: doc: Cond -10/06 I Date: . 0 D08 -037 Printed: 01 -31 -2008 SITE LOCATION Y Tenant Name: Property Owners Name: Mailing Address: Site Address: CONTACT PERSON Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: tkj Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWIL,9 Community Developm . ) epartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Day Telephone: _aO(p _ x030 b � ' v42- rinwocs kJ A R 0�3(o n �1 City [ State M� Zi h GP(' Q �- -` W w1 Fax Number: `f� 5 8 a03 5 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) 0,61 s- ir,dot) f h s Gfi(67 & Q YO LUa (. 3 gy GrA City S t e Zip V 1 Da Telephone: O g5 58 L5 Fax Number: 3(90 8 4-3L Expiration Date: G $$ L C Y 0OQ 1` A P.108 Contact Person: E -Mail Address: Mkt Contractor Registration Number: W A I L S41 I q 131 ARCI=IITECT OF RECORD` All plans t stamped by Architect of Record Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** alug Ave, 5 m HP contact when your permit is ready to be issued Building Pe echanical Permit No. PIumbing /Gas. Permit No Public Works Permit No Project No. (For office use only) King Co Assessor's Tax No.: ' 5 a 3 o4 ! 0 Q 8 Suite Number: cD New Tenant: L>1 nk DQ city State City Day Telephone: Fax Number: City Day Telephone: Fax Number: 7d 1 v Floor: ❑ .... Yes ❑ ..No State s must be ENGINEER. 0 ]E -All plan ainped by Engineer! of Record State Zip Zip Zip Page 1 of 6 L aY A al, V 1 L1c1Y111 Al IA' I—PAN1Ml1111V11 GUU ^!1.71 —.,7V l -V I Valuation of Project (contractor's bid pric�: $ D ., DD Scope of Work (please provide detailed information): Will there be new rack storage? ❑.... Yes 1 No If yes, a separate permit and plan submittal will be required. Provide All Building Are in are'-Footage Below lst Floor 2n° Floor. 3' Floor Floors ru tt aseme Acct Sgry .'Strue Detavited Garage Atta Detached Carport Covered Deck Uncovered Deck Interior Remodel Addition Existing Structure Type of Occupancy per I»C PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:'Applications\Forms- Applications On Linel3-2006 - Permit Application. doc Revised: 9 -2006 bh Existing Bu.iding Valuation: $ t ur mo( {--1 Compact: Handicap: ❑ No If "yes ", explain: Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets • Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: E Mail Address. Contractor Registration Number: Contact Person: ) N O ai—e." / Valuation of Plumbing work (contractor's bid price): $ 00 Valuation of Gas Piping work (contractor's bid price): $ ---� -- Scope of Work (please provide detailed information): Q:\Applications\Forms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh City State Zip Day Telephoner;, O Lp // RT �e L iu Fax Number: Expiration Date: Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): / Utility Purveyor: Water: �i 54 Sewer: Gk. ( V-0 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 9U days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: 3 ED AGE BUILDING 0 Signature: Print Name: OR A I Date Application Accepted: Q:\Applications\Forms - Applications On Line \3 -2006 - Permit Application doc Revised: 9 -2006 bh Date: I — i B nn I Day Telephone: C:(:) wood 0.JA City State Staff Initials: Zip Date Application Expires: Page 6 of 6 RECEIPT NO: R08 -00270 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Initials: JEM Payment Date: 01/31/2008 User ID: 1165 Payee: STEPPING STONE VENTURES SET ID: 0131 SET NAME: STEPPING STONE VENTURES SET TRANSACTIONS: Set Member Amount D08 -033 25.92 D08 -034 65.70 D08 -035 65.70 D08 -036 65.70 D08 -037 65.70 D08 -040 65.70 EL08 -102 66.00 TOTAL: 420.42 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description BUILDING - RES ELECTRICAL PERMIT - RES STATE BUILDING SURCHARGE SET RECEIPT Total Payment: 420.42 Amount Payment Check 6761 420.42 TOTAL: 420.42 Account Code Current Pmts 000/322.100 327.42 000.322.101.00.0 66.00 000/386.904 27.00 TOTAL: 420.42 7895 01/31 9710 TOTAL 420.42 • 50 SEPARATE (PERMIT REQUIRE FOR: LJ Mecha ical Iectric Plumbing LJ Gas Piping City of Tu wila BUILDING DI ISION " AS -BUILT A PORTION OF THE S.E. 1/4, S.W. 1/4, SEC. 15, T.W.P. 23 N., R. 4 E., W.M., IN KING COUNTY, WASHINGTON EDGE OF PAVEMENT 8. 140TH 8T. 8. 1418T. 8T. 0 (U 30' .;.., Plan review approval is stdrject to errors and App : of construction documents nts does not the ti .lation of any adopted .. • or ordinance. Race of . : • Field Copy` ..__..:_LEI • .: Is j 3 I /09i City of Tukwila 3D BUILDING DIVISION BA818 OF BEARING SOUTH LINE OF S.V. 1/4, SEC. 15. T.VP. 23 N. R. 4 E., N87 AS SIOVN ON RECORD OF SURVEY AS RE- CORDED IN VOLUME 97. PAGE 155. RCORDS OF KING COUNTY. WASHINGTON. • INSTRUMENT USED A FIELD TRAVERSE USING A SOKKIA 3100 TOTAL STATION INSTRUMENT VAS USED TO ESTABLISH THE RELATIONSHIP BETWEEN THE COITROLL INC MOMUMENTATION AS SIOVN. LINEAR AND ANGULAR CLOSURE OF TRAVERSE MEETS THE STANDARDS OF VAC 332 - 130 - 090. LEGEND I 1140i l9 FOUND IOAJWENT AS NOTED ® CALCULATED NONUCNT RECORD OF SURVEY AS RECORDED IN VOL. 16, PG. 20. MONUMENT DESTROYED DURING NEW CONSTRUCTION O INTERNATIONAL BLVD. (PACRIC HWY. SOUTH) O SET No. 5 RE BAR AND I.D. CAP REFERENCES TITL REPORT ORDER NO. 1145210 PREPARED BY CHICAGO TITLE INSURANCE CONPNIY. 2. THE FOLLOWING RECORD OF SURVEYS VOL. 97 PG 155 L 156, VOL. 16. PG. 29, VOL. 44, PG. 200, UNRECORDED SURVEY BY EARTHTECH DATED MARCH 1999 AND PLAT OF JAMES CLARK'S GARDEN ADDITION TO THE CITY OF SEATTLE, VOL. 13 Cr PLATS. PG. 12. AND THE PLAT OF ROBBINS VIEW TRACT ADD.. VOL. 17, PG. 90. 3. ADDITIONAL RIGHT OF WAY AouIREp ALONG INTERNATIOML BLVD (PACIFIC HVY. S.) AS PER WARRANTY DEEDS AS PER RECORDING No.'S 20020416003155 AND 20020416003156 CONTAIN NUMEROUS ERRORS AND CAN ICT BE ESTABLISHED. RIGHT OF WAY (RAVINGS REFERED TO IN LEGAL. DESCRIPTION CO NOT EXIST ACCORDING TO TIC CITY OF TUKVILLA ENGINEERING DEPARTMENT. (IIPROVEIENT DRAVINGS OILY) 4. IDIBBENTS IN INTERNATIONAL BLVD. ,(PACIFIC HIGHWAY SOUTH) HAVE BEEN DESTROYED DURING NEV CONSTRUCTION CENTERLINE ESTABLISHED FROM SURVEY BY V. HINE SURVEY DATED AUGUST 1978. LEGAL DESCRIPTION THAT PORTION OF LOT B, BLOCK 1, JAMES CLARK'S GARDEN ADDITION TO TIE CITY OF SEATTLE, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 13 or PLATS, PAGE(S) 12, IN KING COUNTY, WASHINGTON LYING EAST or THE EASTERLY MARGIN OF STATE ROAD No I (PACIFIC HIGHWAY SOUTH) AS ESTABLISHED BY DEED RECORDED UNDER RECORDING NUMBER 2014233; EXCEPT THAT PORTION THEREOF CONDEMNED FOR PUBLIC ROAD AND HIGHWAY PURPOSES IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 6099481 TOGETHER VITH TIC NORTH 322.7 FEET IT THE VEST 520 FEET EF THE EAST 540 FEET OF THE SOUTHEAST QUARTER OF THE SOUTHVEST QUARTER OF SECTION IS, TOVNSHIP 23 NORTH. XCEPT RANGE HAT PORTION THEREOF CONVEYED TO THE SST I Ai COUNTY. WASHINGTEN. OF WASHING TEN FOR STATE ROAD No I (PACIFIC NIGHVAY SOUTH) BY DEED RECORDED UNDER RECORDING PANDER 2048144, AND EXCEPT THAT PORTION THEREOF CO4DERED FOR COUNTY RIGHT O WAY (42ND AVENUE SOUTH) IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 614098; TOGETHER VITH THAT PORTION OF VACATED 40TH AVENUE SOUTH (CONNECTION STREET) LYING EASTERLY or STATE ROAD No. 1 (PACIFIC HIGHWAY SOUTH) AND ADJOINING ALL THE HEREIN ABOVE DESCRIBED PARCEL OF LAND; EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF TIXVILLA BY DEEDS RECORDED UNDER RECORDING NUMBERS 20020416003155 AND 20020416003156. (LEGAL DESCRIPTION FROM CHICAGO TITLE INSURANCE ORDER No. 1145210) FILE COPY �„n�. 31 CITY OF RECEIVE JAN 18 2C PERMIT CEN TER PO'O3* RV C/O .ERRr INg80T11E ROSEN-1MRB0T1 E WIRIE RCYL REAL ESTATE 1715 114Th. NE. S.C. SUITE 212 13011 WA91MGTON 98004 A PORTION OF THE SE I /4, S34.1/4, SEC. 15. T.W.P. 23 N. R 4 E., 11.11., N KBLG Down% BASINGTON VAN CLEAVE AND ASSOCIATES 112 CANDLEWICK DRIVE WEST Premium Vinyl Skirting. Easy to Install. Easy to Maintain. t)75O unlxixu,l hil lm 'pmgy Lxl nFiwoloq(19xxk,1j %ptvuoiiuo103I01- r)-0rl IMpo uoly iopr) 'NA (I !UN pur srt•i (I ICISV .ix1 olit PIT il i i novuy'axojr of avtp )r Io upu 3 yu¢a) .ui nrxl) pgiixiaymag ")uu trin,>; :t (I IRJSV orowrawnlU u painiip `' l»inothu i l )41) ( 'ol'P 14) 14x1 og n I rei j moglogpav pr) pim0dnmi . 1116 85 000`61£ 000`89£ 0085 00£9 •ulul1/ 9•£. plop%,(jisin(l a)lotus s)gia(lakl aatleis!saHanuatD upartm lanais it 5-01T `iiot slmdaS1 `� ..:• �. IrtuaagI aeann jo Iuaiagiaop tsd ”Z 0 On) aan)PJadtuay UoIaalla(l pall (Isd) shinpoiAl allsuat (isd) g1'ua11g ajtsua. •tJ) „L'113 indult port ( /• - IJ) „Z£ )1 Iat:dult port parpul;IS Pati'puuiS W.LSV d -9 :sparpums punodwoa IV LSV StI!MolloJ )111 lltlAl Salldaloa (aA(1)appolga I,iil!Mlod papn.ux,t settiodoid iD3!sAgd salon a)Irds Ina -aad !pm "Soot ,Z-1 `ll „Zit 1 puutigD punoa9 aqy •c •slaul:(I pllos Jo p llIaA:la1llaa ul alqujfl q+ 'gaol ,Zl 'aptnt „91 lauud a'LL •£ Yu(II ,Zl ` g1 1 1 „Z. /l± l!"U VER doj aqj, j►1g 1 10a3 doj, al(,)(, •1 suo!;D»IJIaads Pnpo.1d Add the finishing touch of Chateau skirting. The distinctive cedar grain look is a result of our state -of -the -art manufacturing process, and is perfect for manufactured homes, decks, foundations, porches and hot tubs. Unique center vent design. Each panel has a built -in center vent so separate ventilating panels are not necessary, giving you an overall look that is much more attractive than regular skirting. ■ The rich texture and character of woodgrain adds an elegant touch to any home. Easy maintenance... no painting! Chateau vinyl skirting is easily cleaned with just a garden hose. Stubborn dirt can be quickly cleaned with a solution of ordinary dishwashing detergent and water. Stands up to the weather. Chateau vinyl skirting fits snugly, yet has the flexibility to maintain its integrity during high winds. Durability that's guaranteed. High -quality vinyl meets ASTM standards and is suitable for any climate. And it won't dent, conduct electricity or attract insects. Chateau skirting comes with a Lifetime Limited Warranty against peeling, blistering, rot, rust and corrosion. 0 co c..) >D N W CO LL W0 CC r Q I Simple do- it- yourself installation creates beautiful results. loot N }!M nog( 0:.tuow®Ao Idw! 4 ta�aol4Dpo ;su! pad +.of selllo; iiowIuoa XIS Install Chateau today & enioy tomorrow. Using simple household tools, you can add the beauty of Chateau skirting. Use this brochure to help figure your materials and to review the simple steps to install like a pro. Check with your home improvement specialist to assist you or answer any questions. (Due to printing limitations, colors may not be exactly as shown. Contact your distributor for actual product samples). Chateau color choices let you bring out the beauty of your home. r• ra 1 New top -rail design resists warping and blowout. Pre - notched front top rails allow for expansion overlap and help reduce installa- tion time. 2 Removable -panel design lets you store garden tools, lawn furni- ture, and children's toys out of sight — but not out of reach. 3 New panel profile adds strength and provides extra security against wind loads. Extra -wide, 16 -inch panels mean fewer panels to cut — which saves even more instal- lation time. 4 Unique design lets panels self - adjust to ground -level fluctuations due to changes in weather condi- tions. These installation guides also keep panels from snagging on rail fasteners during frost heave, thereby preventing buckling. 5 Special interlocking panels keep the panels secure and the locks hidden so they don't detract from the appearance of your home. 6 Ventilated panels are required to help eliminate moisture buildup and allow for proper air circula- tion. (Check your home's specifi- cations for proper ventilation requirements.) 7 "F" shaped bottom rail design (instead of a narrow "U" shaped channel) provides a stable founda- tion and prevents the channel from buckling. ✓ With a tape, measure the perimeter of the home, deck, or hot tub you wish to skirt, making sure to measure the entire perimeter, including bays and porches. ✓ The chart below shows some typical size homes and their corresponding linear measurements. ✓ To determine the average height, first measure the distance between the ground and the bottom of what you're skirting. ✓ Take this measurement at each of the corners and at the cen- ter of each side. ✓ Total all six of these measurements and divide by six to arrive at the average height. The worksheet at the right is helpful. ✓ Next, find that height in the chart below. Scan over to the point under the approximate linear footage of your project. That will be the number of skirting panels you will need to order. ✓ For the top rails, top back rails, and ground channels you'll need, look only in the column under the linear footage that come closest to your project. Then gather your tools and begin the installation! 764,4 S tep T , 4 61 i S tep five — Di ^Te 8 And the bottom rail design, with its precut slots for ground spikes or cement screws, allows for ease of installation on concrete or directly on the ground. (Several different component colors are used in photos for enhancement purposes only). Size of Home 50' Perimeter 120' (linear measurement) 55' 130' t'L 140' 150' 60' 65' 70' 160' 60' 144' i x 65' 1 1 g 70' 158' 162' 80' 182' 60' 148' •1 x 162' 166' 65' 70' 80' 188' 60' 154' 65' 174' 70' 180' 2'x 182' 192' 65' 70' Height of Skirting (Panel Cut Length) Number of ' anels Re ' uired 16' -18' 12 13 14 15 15 14 15 16 18 14 16 16 19 16 17 18 18 18 ESE Construction Inc. Ron Soini 7189 F &S Grade Rd. President Sedro Wooley, Wa. 98284 360 - 708 -3599 360. 856.4346 fax WAINS #1937 11108 ESECOI *000RA 12/08 RECEIVED CITY OF TUKWILA JAN 1 8 2C' "8 PEI f GEN.TER Any size manufactured home 12 wide to 70' long State approved tie downs even 11' on center Manufactured Home Main Beam Typical blocking and tie down Installation to Washington state code 8x8x16 hollow concrete blocks set on 2 ea, 4x4x8 solid concrete blocks (pad) Or state_appr v d metal stands on pads with wood shimes and wedges.. • • Foundation pier blocking 8' center to 12' center Perimeter block at every door and window larger than 48" D 03� . Minute Man September 21, 2005 Dear Scot Sincerely David A. Dahmen P.E. Pt.k Mr. Scott Moreno Minute Man Products, Inc. 305 West King Street East Flat Rock, NC 28726 Pacific Consulting 2150 Bell Arc.. Satre 145 • Sacramento, CA 95838 • (916)5644028* Fox: (916) 564 -6029 RE: State of Washington Engineer's seal Please be advised my Washington Engineer's license has been renewed to 7/17/07. I havc stamped and signed by seal on this letter. I have re- sealed the Engineered Tie Down plan and details with the updated WA seal and have mailed the plans to you for your use. 828 692 0268 09/22/05 08!B8am P. 002 i0. )040047 r_rIl Engineers RECEIVED CITY OF TIJKWILA JAN 1 8 2008 PERMIT CENTE8 rn. 1 a rVT— MLyL34 FRAME TIE /row r srt[c !raw TM NGL[ .. q.EA4 SHOWN. =Ei . •' ?FC — .HASS = rCR :NV ,e C BONN CntivECTyNi ',urE .:E S OE :2 ooWN Minute Man NC4636, EZDH & MMA34 EARTH AUGER TIE DOWN CHASSIS ORILL 9/16' HOLE AT W0 HEIGHT OF BEAM. s1STALL l /s- A307 BOLT. 828 692 0268 MMA34 !RAMC TIE STAMMER PLATE 4 MD or KEW OF 1 NA T. Srii. STRAP 5tE"T'i3EAM CHASSIS ANCH OR FOR TEE oown ' STEEL !TRAP SEE ANCHOR fOR TIE DONN ANCHOR 09/22/05 08LS0am P. 004 2—ow. SNOWN. at C - k Ri°0 FDR END TIL DOWN COMYECT0N5 MI TIE DOWN 'F EARTH AUGER TIE DOWN "C" BEAM CHASSIS ° RFC ° BEAM CHASSIS INSTALLATION INSTRUCTIONS 1. THE DRIVE MACHINE IS STARTED AND THE ANCHOR I8 TURNED INTO THE GROUND TO A POINT WHERE THE TOP (STABILIZER HEAD PLATE) IS I=LUSH OR SLIGHTLY BELOW GROUND LEVEL THIS INSURES THAT THE 62 ANCHOR STABILIZER WILL BE AT ITS REQUIRED INSTALLATION POSITION. 2. FOR THE E ANCHOR/STABIUZER TO ACHIEVE FULL POTENTIAL, INSTALL THE ANCHOR VERTICALLY WITH NO DEVIATION GREATER THAN 10 DEGREES. NOTE A SLIGHTLY GREATER ANGLE MAY BE USED TO START THE ANCHOR TO AVOID CONTACT WITH THE HOME & STRAIGHTENED AS THE ANCHOR IS GROUND SET. THE SPLIT BOLT IS INSERTED, STRAP FASTENED, AND TIGHTENING ADJUSTMENT MADE. • NOTE: WITH MACHINE INSTALLATION, A MINUTE -MAN ADAPTER DESIGNED TO FIT BOTH THE ANCHOR HEAD AND DRIVE MACHINE SHAFT IS AVAILABLE. INSTALLERS DO NOT NEED ADDITIONAL OR SPECIAL EQUIPMENT FOR E -Z ANCHOR INSTALLATION. NOTE: AN ADDITIONAL STABILIZER PLATE IS NOT REQUIRED WITH EZDH & GW2 EARTH AUGER TIE DOWN. CONCRETE TIE DOWN CitOSS DRIVE TIE DOWN MMA34 FRAME TIE /700 7 STEEL SrR.,P 0 W/ BucM�t t SNOWN. SEE C'& RFC CHASSiS FOR ENO TIC DONN tO wmortio16 MAIM' SILL TIC DOWN I ORM ANCHOR STAMER PLATE r / GROUND LINE M CRASS DRIVE w/ 5 AB!LI7rR — — FIRST CHECK FOR UNDERGROUND UTILITY LOCATION: EZDH EARTH AUGERS 1, SEE DETAIL THIS BOOKLET FOR INSTALLATION INSTRUCTIONS. EARTH AUGERS 1. INSTALL AUGERS INTO SOIL WITH CONSTANT DOWNWARD PRESSURE TO MINIMIZE SOIL DISTURBANCE LEAVING APPROX. 17 OF SHAFT EXPOSED. 2. INSTALL STABILIZER PLATE - DRIVE FLUSH WITH GROUND SURFACE 3. COMPLETE TURNING AUGER INTO GROUND UNTIL AUGER HEAD IS FLUSH WITH GROUND SURFACE AND TOP OF STABILIZER PLATE. CROSS DRIVE ANCHORS 1, CROSSDRWVES ARE USED WHERE HARD ROCKY SOIL OCCURS. IF THE GROUND SURFACE IS OTHER THAN ROCK OR MINIMUM 2" ASPHALT, INSTALL MMA -SD2 STABILIZER PLATE, OR PLACE 12k12'k17 DEEP CONCRETE. •' • CONCRETE SLAB ANCHORS 1. CONCRETE SLAB TO SE MINIMUM 312" THICK AND IN GOOD CONDITION. 2. MINIMUM SLAB AREA REQUIRED FOR EACH ANCHOR IS 28 SQ. FEET. • 3. DRILL PROPER SIZE HOLE IN SLAB MINIMUM 12" FROM ANY EDGE. ALL APPLICATIONS 1. ATTACH STRAPS TO CHASSIS BEAM IN MANNER SHOWN. 2. INSERT STRAP THROUGH SPOT NUT. CUT OP EXCESS STRAP AND TIGHTEN UNTIL SNUG. TEE DOWN LOCATIONS DID TIE DOWNS SEE 0 ART Mirwt® Man OM Tit DOWN'; SCE CitARf SINGLE WIDE INSTALLATION INSTRUCTIONS 828 692 0258 DOUBLE WIDE EARTH AUGERS _J CROSS DRIVE ANCHORS MAX. WWII OF 37 47 57 MFO'D HOW • - MAX I.EN: Tn Of uFO'o MAL ND. OF SITE 2 11E DOWNS 38' 54' 72' 3 4 f IAAX t43. OF GUI 3 4 5 57 8 73' 7 CONCRETE SLAB ANCHORS imam= mi. Loom OF 3 42' 817 Wvc NIX OF MOS TIR 4 5 B 7 8S' 8 _ NOTE: I S DE nE DOWNS AT 2'-U' FROM EACH END HAVE TOLERANCE THE � OF 1D�S AT THE 2' LOCA"�ON SHOWN -•-� �- 18" MIN. 10 10 6 DOLT ON TOP PER 09/22/05 ut4too•41 • b,>tSOVINS SEE CHART TRIPLE WIDE a+ END TIE DOWN NOTE: 11 DOWN STRAPS*1' THE CHASSIS BEAM ENDS {END TIE DOWNS) CAN BE ATTACHED TO A CHASSIS IFRORT P;'. w rrH A PIEa.BOL T ON TOP. (SEE SKETCH ABOVE). N LU d Minute Man 828 892 0258 09/22/06 08158am P. 003 MINUTE � s C e H E ORS, INC. EAST FLAMM NC 2S726 ENGINEERED TIE DOWN SYSTEM DESIGN & GENERAL NOTES DESIGN LOADS - • WIND • SOIL BEARING •- --�- -� 15 PSF PSF • • TIE DOWN STRAP 31501 WORKING LOAD * SEISMIC ZONE - 4 TIE DOWN STRAPS TO BE MIN. 1 114" WIDE x 0.035 THICKNESS ZINC PLATED AND MEET ASTM D- 395391 • EARTH AUGERS - 2962# MIN- (TESTED TO 47501 MIN.) • CROSS DRIVES 1727 # (CALCULATED) • CONCRETE SLAB ANCHORS 1390# (CALCULATED) AML NOTES: 1. THE CHARTS SHOWN HEREIN ARE FOR THE REQUIRED NUMBER OF TIE DOWNS ON THE SIDES OF THE MANUFACTURED HOME. 2. TIE DOWNS ARE REQUIRED AT EACH CHASSIS BEAM, EACH END OF EACH TRANSPORTABLE SECTION OF THg MANUFACTURED HOME AND CAN BE ANY OF THE TYPES SHOWN HEREIN. 3. COMBINATIONS OF THE DIFFERENT TYPES OF TIE DOWNS CAN BE USED. 4 IN THE EVENT AN EARTH AUGER CANNOT BE INSTALLED DUE TO AN OBSTRUCTION, USE OF CROSS CROSS DRIVES ARE INSTALLED O FOR EACH EARTH AUGER THAT CANNOT BE (2) INSTALLED. 5. FOR ALL TIE DOWN INSTALLATIONS, THE MFG'D HOME CHASSIS MEMBERS ARE SHOWN AS "P BEAMS. FOR ILLUSTRATION PURPOSES ONLY. CHASSIS BEAMS CAN ALSO BE "C" SHAPED OR "RFC' SHAPED. S. END TIE DOWNS CAN BE LOCATED WITHIN 24" OF EITHER SIDE OF CHASSIS BEAM AXIS AS SHOWN. ▪ h 7. THE SIZES, TYPES, LENGTHS, ECT. OF MATERIAL SHOWN HEREIN ARE MINIMUM. LARGER, LONGER, HEAVER MATERIALS SUPPUED BY MINUTE -MAN PRODUCTS. MAY BE USED AT THE SAME SPACING & LOCATION SHOWN. 8. ALL PARTS ARE STAMPED MMA- WITH THE APPROPRIATE PART NUMBER. 9. THIS TIE DOWN SYSTEM CAN BE USED WITH 10' WIDE MANUFACTURED HOME SECTIONS WITH 100" CHASSIS CENTERS PROVIDER THE HEIGHT FROM GRADE TO THE BOTTOM OF THE CHASSIS BEAM DOES NOT EXCEED 19". 10. TIE DOWN STRAPS IN THE LONGITUDINAL OR TRANSVERSE DIRECTION CAN BE BOLTED TO THE HITCH ATTACHMEN'► PLATE THAT IS WELDED TO THE CHASSIS BEAM: Minute Man TLW 01 -03 MMASD2 5Tr8IUZER PLATE STABILIZATION PLATE WELDED TO ROD GUIDE & STRAP HEAD AZTEX ANCHOR CROSS DRNE ANCHOR w/ 3/4 "0x32" RODS MMA- 21OJD1i UMA 210POH STABILIZER CAP COMPACTING DISK 828 BaL iaLSts NC4636 7/8 DIA 38 AUGER ANCHOR USE OuTS7DE HOLES FOR 4 " FLANGES SL. MMA -35 CROSS ORNE ANCHOR W/ 23/32 RODS MMA SPOT BOLT sk NUT MMA -1 B CONCREIc SLAB ANCHOR - LIMA 6 3/4 DM 4430 NU 3/4 MM 32 STEEL STRAP w /BUCKEL TOP PUT£ 801TCM PLATE Mk4A - 34 LONGITUDINAL FRAME TIE AND CLAMP (FOR WIND ZONE s) MMA- 34 BOTTOM PLATE LOCATION OF tr DIA MA -71 STEEL T RAP w /CORNER TIE TOP PLATE BEAM G&E MODE NOLfS FOR r - J' RN+►OES 4- 1} tzb' GRADE 6 NACNINE BOLTS S IGN STRENGTH wASHERS ANA 7 CORNER TIE MATS RW NEAREST TO MMA -9 i 5/8 DIA MMA -92 3/4 DIA MMA -94 3/4 OJA MMA -650 3/4 014 4430 OH 3/ DIA 32 " R ANCHOR 32 "AUGER ANCHOR 36 - AUGER ANCHOR SO ANCHOR 30' AUGER ANCHOR CHOR NE ROD August 11, 2008 Erin O'Leary 20303 10 Av W Lynnwood WA 98036 RE: Request for Extension Development Permit No. D08 -035, 036, and 037 Southgate Mobile Home Park —14005 42 Av S, Units 26, 27, & 28 Dear Ms. O'Leary: This letter is in response to your written request for an extension to Permit Numbers D08 -035, D08 -036, and D08 -037. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. These permits are replacements for D06 -106, D06 -107, and D06 -108 that were extended and then expired. One extension is permitted for the same work, and this was done on the 2006 permits. Subsequently these current 2008 permits cannot be extended again. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, fer Marshall it Technician Cary of Tukwila Department of Community Development Jack Pace, Director File: Permit No. D08 -035, D08 -036, & D08 -037 P :\Permit Center\Extension Letters\Denials\D08 -037 Permit Extension Denial.doc Page 1 of 1 jem Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Jul 17 08 02:06p Erin O'Lear RECEIVED OOMMUNiTY OENELOPME 1 a.o(R) 206 - 439 -1355 32A 4 e4' f1k1,p c'd -4- - 53iLL, , :: Ic 6.0D 1-tic Pal vcfi l 00 G-L_ C.5" .6 ' +116 rIA• `4 eio p.1 IC}e ' eeNC b ?E 1t Ate verepcem i rs Fee 1,010 -10101 101 10g 1VAr Waite swraRDFLD WED 1306 .035, 036, 4.o 7 cANN40( ,)treN®EO 44444. ONE ta �Ktta FOE. roe ANC T-t Wets P0NO Tp COS (ExpI EP) ITS. Islavo W./% C I$►H Z AAN „ i t GOWN L -t r- u-t_51 o Y\ bo% o Dos - o 3 ia , o oy -O3) we. are. s+:.11 (00k,�� - zrr G•p p v� w 0 4 C-:► v, — -2y( ; �, - h o..S-e- Sr Is 6,5 • No )e'wwc\- � 0 � -�1 l • _ �,� Li/ , f s'. \ o4 or -LL., - -R►6Q J& � 4 olitc 1f \4 Vim- +L. LO i l ( 0 E i/ /Bo /24415 .1)(1 a0' 6/1" ot(ri, V1 07 06 -05 -2008 ERIN O'LEARY 20303 10 AV W LYNNWOOD WA 98036 RE: Permit No. D08 -037 14005 42 AV S TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, er Marshall, Permit Technician xc: Permit File No. D08 -037 Department of Community Development Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/29/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: D08 -037 DATE: 01 -18 -08 PROJECT NAME: STEPPING STONE VENTURES SITE ADDRESS: 14005 42 AV S #28 X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: _ -I A§ Bu ''+ g ion Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY • PLAN REVIEW/ROUTING SUP Structural TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: Response to Incomplete Letter # Revision # After Permit Issued Fire Prevention I Planning Division n Permit Coordinator Incomplete n Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 01-24-08 LETTER OF COMPLETENESS MAILED: No further Review Required DATE: n DUE DATE: 02-2 1 -08 Approved ❑ Approved with Conditions I Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire ❑ Ping ❑ PW ❑ Staff Initials: • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E -mail: tukplan0ci.tukwila.wa.us AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) COUNTY OF KING ) ss. £� O -4 \ [please print] C , states as follows: PERMIT NO: 6 ) (` Owner /Owner's Agent Signed and sworn to be. re e this day of Residing at Name as commissione.: My commission expires: Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 - 0179 Planning Division 206 431 -3670 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under No. 13 , and will therefore not be performed by a registered contractor. understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to ersons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construc • i work. 2O. NO C in and for the State of Washington r , County 18.27.090 Exemptions, The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; io. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; ii. An owner who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12. Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a.valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work.