HomeMy WebLinkAboutPermit D08-045 - INTERGATE EAST (SABEY) - BUILDING 4 - CHILLER WALLINTERGATE EAST BUILDING 4 3433 S 120 PL D08 -045 Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Tenant: Name: INTERGATE EAST - BUILDING 4 Address: 3433 S 120 PL , TUKWILA WA Citylkf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Phone: Contact Person: Name: DAVID KANG Address: 12201 TUKWILA INTERNATIONAL BL , TUKWILA WA 98168 Phone: 206 - 277 -5243 Permit Number: D08 -045 Issue Date: 03/24/2008 Permit Expires On: 09/20/2008 Contractor: Name: SABEY CORPORATION Address: 12201 TUKVVILA INTL BLVD 4TH FL , SEATTLE WA 98168-5121 Phone: (206)281 -8700 Contractor License No: SABEYC *953RE Expiration Date: 12/05/2009 DESCRIPTION OF WORK: REBUILD OF EXTERIOR CHILLER WALL AT INTERGATE EAST 4 CAMPUS Value of Construction: $132,220.00 Fees Collected: $2,492.04 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: V -A Occupancy per IBC: 0013 doc: IBC -10/06 * *continued on next page ** D08 -045 Printed: 03 -24 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: Signature: Print Name: JOSrt 1a14.t90 doc: IBC -10/06 City dlTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Water Main Extension: Private: Public: Water Meter: N 1 !i Date: 3 /ay /g Permit Number: D08 -045 Issue Date: 03/24/2008 Permit Expires On: 09/20/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N 3 ~ Z L i 0 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -045 Printed: 03 -24 -2008 Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Tenant: INTERGATE EAST - BUILDING 4 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall. be maintained and made available until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be required. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Masonry construction shall be special inspected. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 � • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * * continued on next page ** Permit Number: D08 - 045 Status: ISSUED Applied Date: 01/29/2008 Issue Date: 03/24/2008 D08 -045 Printed: 03 -24 -2008 Signature: Print Name: Js . N,Js 0,1 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 04/2' D08 -045 Printed: 03 -24 -2008 King Co Assessor's Tax No.: le 2,3e / — ¢d'frl' -Q Site Address: 3 93 3 S0 ;, i /20 .1 " Pd arm viws /q. 10 Suite Number: Floor: #ij ... V 00..1-L=1_ liv 41-4 New Tenant: [i .... Yes g..No Property Owners Name: ..../.17 4T /,.,R t_. Fi4rsw,ay P,{$T , i.t.t' £ Lk) r,� 9 14- Fcst___ Tenant Name: Mailing Address: /Z2 / J ic-# Name: '7> A v 1 b p. ) 44 N 6. Mailing Address:. / "2 2 a 1 T u Li,v i't. E -Mail Address: pl A V l p0 e 0 S d ta e t ) - e o vvv . Company Name: Mailing Address: Contact Person: A^' t<_ /6 f7 M e 15 E -Mail Address: V'4 k/ (. / o (J S of L t o • Contractor Registration Number: 5IME/ C 4 9 53 AE Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKW/L 4 Community Developmer,, Jepartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA. 98188 hup://wwwci.tukwilawa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 54-66- t" ON STrz tl C 7 OA/ /7 ,'L,4 /Mi °L / S S/ 9/ A i T eTU /Z2)t "TL,LWit. INs't, r3 ty S¢I Np2 $ v S c44 d e Q: \kpplications\Forms- Applications On Line\3 -2006 -Permit Aoplication.doc Revised: 9 -2006 bh l•T 'c ge 4-4 Clty City . Seo#64 Cit State 9 8/68 Zip Day Telephone: (3.°i) Z99 — 5 t% 3 6t /O Y' FLn- eMk4. (ia4 g /fi State Zip Fax Number: `20 0 Ze2 - J! S/ kA14 O State Zip Day Telephone: C(' 2_33 — S 2g 3 Fax Number: ( 2 2 - 9 9 S/ Expiration Date: �J M 172- semiM— (An 9f/6 cit State Zip Day Telephone: (3 (v) 29 5;2.9- / Fax Number: ( . . ? . . 1 6 ) 2 8 - z - f 9S/ City Day Telephone: Fax Number: State Zip Page 1 of 6 B JILDli1T RIVLI ORMEY 0 2�06;4313?6R 7 Y Y. , T j.�,YA :,.. „y i X � . x �c a � .#W Y D. t-.� -,# .1i '�5 „ee,+� Valuation of Project (contractor's bid price : $ 1 Z, Z'Z Scope of Work (please provide detailed information): 1 2 ' F Ru, L. A A T /N'tae 6. A- Tr E?9'Sr L( C im1p 6 S • Will there be new rack storage? ❑.... Yes O:\ Applications\Forms- Applications On Line\3 -2006 - Permit Application.doe Revised: 9 -2006 bh , Existing Building Valuation: $ q q , 6 0 0 O F F)c E, Fr2 C X .. No If yes, a separate permit and plan submittal will be required. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: - Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: P Handicap: Will there be a change in use? ❑ • Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 1 Sprinklers • Cr Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? Y ❑ If "yes', attach list of materials and storage locations on a separate 8 - 1/2 "s lI" paper including quantities and Material Safe Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Print Name: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERI IFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER OR AUTHORIZED AGENT: Signature: D r4V /0 Date Application Accepted: D. Q: Wpplications\Forms- Applications On Line.3 -2006 - Permit Applica' ion.doc Revised: 9 -2006 bh )-C4N1-, licalletoall permlfs ><n:ls �a Date Application Expires: e Date: / —D Day Telephone: ( ' 9_99- — 52 Y 3 Mailing Address: (220 / 1 tcw;04 /NT 1 L- i3 L dr it Ft-Z s cat ( �vr � . 9V 6 S- City State Tap Staff Initials: . Page 6 of 6 Receipt No.: R08 -00254 Payee: SABEY CONSTRUCTION ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Co Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Permit Number: D08 -045 Address: 3433 S 120 PL TUKW Status: PENDING Suite No: Applied Date: 01/29/2008 Applicant: INTERGATE 4 CHILLER WALL Issue Date: Initials: WER Payment Date: 01/29/2008 03:10 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 40858 2,492.04 Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Payment .Amount: $2,492.04 1,507.60 979.94 4.50 Total: $2,492.04 7771 01/29 9710 TOTAL 2492.04 doc: Receipt -06 Printed: 01 -29 -2008 ProjfPSt.. ,,1 Type of Inspection: Ar.A Address: 2 4/3,3 s /2e Pz Date Called: Special Instructions: 7x1 _( fir 7'---.57 1 /16 Date Wanted - /3 - Q� d p.m. Requester: Phone No: 55-* :Z 7 / 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. a COMMENTS: Inspector:�� �� Date: to it J Q ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (D E h $ L LLB, SPf. e- (nit.._ ► vlS Date: ti MAYES TESTING ENGINEERS, INC. PS;t fn.14.1V ut. •P1?SifiT 1 August 14, 2008 City of Tukwila Building Department 6200 South Center Blvd Tukwila, WA 98188 -8188 Attn.: Building Official Re: Sabey Microsoft Chiller Wall Upgrade 3433 South 120 Place Tukwila, WA MTE Project No. T08098 Gentlemen: This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. Special inspection was provided for: 1. Epoxy Grouted Dowels 2. Reinforced CMU Masonry To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to. the city approved drawings, or engineer approved changes. We trust that this provides you with the information that you require. Should you have any questions, give us a call. Sincerely, MAYES TESTING ENGINEERS, INC. RECEIVED JAN 1.2 1089 u....._.,. ',t NT FINAL LETTER Permit No. D08 -045 aun W. Se �iign IT Tacoma Brancfi'1Madager Cc: Marcelo Garces, Sabey Corporation — Josh Johnson, Sabey Corporation Lynnwood Office 20225 ('.Mar Valley Road Suite 110 Lynnwood, WA 98036 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 ^r=z !!,a PY Sa Co IOE Blinding 4 - - d1'" Tukwila; WA . k= -4-zgr; Structural Calculatio CALCULATIONS INCLUDED: Pages 1 through 5 These Calculations cover this scope: Structural design of masonry screen walls for building refrigerator units. ^t17/el 1 KPFF Project No. 107545.10 Date 2/29/08 1601 Fifth Avenue, Suite 1600 Seattle, WA 98101 tDO8O9 RECEIVED MAR 0 5 2008 PERMIT CENTER Consulting Engineers 1601 5th Avenue, Suite 1600 Seattle, WA 98101 (206) 622 -5822 Fax (206) 622 -8130 Project 16E - `4 ScR•( wA`L location client LATE2A1. 6AD OET ERA-A1 VI A' tc1..1 b i^—TS data 2129 /05 sheet no. job no. Se1sti11 C �1� 5 z } '772--- 1n FaS, F = 1. o = 1.530 S a, 3�1 c)0 .53 cD - 1.02 . 1. 1 ca"2. :5 c14-05 16 2 Ga 3 r 1.14 Wt■.►d R-e%s Ury U,,) t = 21 5. 1 ?s- l��s�..n� ip..Nc∎ 1 Pc.r..)65, ave. GK)'' solid 22.E36 z 'GVee ovea 42 20peuniq� G.544� A . pSC'� 12 x -4 + O. �o (26.1 se.% G � + f}) �J = 29`x.73 i6 4- 10 8. (2 Pwt►.3o I00 it° =) Ia0 t5 ef+ 1•333 °I5 Ps. 9S C Sc.) wt► c_001( 01.S. ■ = U, S S„ a l.,.t P 6 " 1.0 X` 2 .5 I li 7 . llZps k 1 ,333 4 x f + b PSG x c x _ 14os 1� '� DL su v -ell J coluMni = S 2 -10 3� _ ' < l 7 f3 1. 333 me, oNS Is 2 - r- Cd' )c 2 c ct.14. 1>ev as but H dv qwv Nis G - - k-.) CT\ U well ve11.1� 1% 4'o Pev as bu c1vJkwlN c.) 4 t►- t01'Le cvt.,JCi1}��us..• New CPJL1 =1.V c / Ex Cti1U Watt in reMalt /— Ex F'}� N04e 'ieJ) 6 .A1 Pakez1 Name Ceinbol Equation Parameter )Unit - Equivalent )Unit Axial Load P #6 157.5 pif 8 in o.c. Wall Thickness t 9.625 in 0.80208 ft Eccentricity e = t/2 4.8125 in 0.401042 ft Lateral Load w 95 psf Wall Height h 8 ft 96 in Horizontal Reaction @ Wall Bottom R, = • — + wh h lb/ft 767.9 — ft Maximum Moment Location (Dist From Top of Wall) _ x • ° — w 8.00 ft Maximum Moment Mmer = w h 2 — 2 Ib'ft 3040 — ft Reinforcement Spacing b 8 in 0.6666667 ft Design Maximum Moment , d,,; g = "max Ib'ft Masonry Compressive Strength m 1500 psi '- -- Allowable Masonry Stress F„,= m — 3 500 psi Steel Modulus of Elasticity E, 29000000 psi Masonry Modulus of Elasticity E„,= 9001' m 1350000 psi n= E. — E 21.5 [ ] Steel Bar(s) Used (1) #6 Diameter of Steel Provided d 0.75 in Area of Steel Provided A.= Pi'd b 4 0.44 in Effective Depth d 4.8125 in P= A , — bd 0.0115 [] k = ((np) 2 +2np) 0 -np 0.498 [ ] 1= k 1 -- 3 0.834 [] Masonry Resisting Moment Per Section M.m = Fmkjbd2 19228 Ib'in 1602 Ib'ft 2 Allowable Steel Stress F, 24000 psi Steel Resisting Moment Per Section A4„= F,A,jd 42562 Ib'in 3547 ib'ft Weight of Wall Section 14 /..• 116 psf Area of Wall Section A 116 in Axial Compressive Stress f, = P + w.r, * (h - x) 1.4 psi A,,, Nominal Thickness t „ 10 in Allowable Compressive Stress F.= 0.2r (1-(12h/40t.) 295.9 psi Allowable Compressive Stress With 4/3 Stress increase 4 F 3 394.5 psi Governing Resisting Moment M, 1602 Ib *ft Governing Resisting Moment With 4/3 Stress Increase 3 M' 3 2136 Ib'ft ) -- Unity Equation Using 4/3 Stress increase With Wind or Seismic Loads f , Mme+,dsslgr + < 1.0 0.952 [ ] F, M, 11V all Summary Nominal Wall Thickness 10 in Actual Wall Thickness 9.625 in Reinforcing Bars #6 Reinforcement Spacing/ Grout S. adv.' 8 in o.c. Coporr Consulting Engineers location 1601 Fifth Ave. Suite 1600 Seattle, WA 98101 (206) 622 -5822 Fax (206) 622 -8130 project 1 C-7 - Scg_k1 WALL client Lc ic1z Co,-u T� CMU \iALL- b date /'•• A-6 OO� vQ �b v1 �cal 0•V v es.cA '-6 St�;e = �I �1► <<r� e (90 - = So4 C .NOo�Q ckmcl r 01"-) dv (j.c.?;N., 4 ()wool ov ZrZ- 11 /� 1 1 575 1 S k9011 LA COpaCrtt.( T 1 O\c Hollow �S1oCL. 7/�' 11h>cl c , , e0 -\, J �JJ P■u, ;_, 1 /4 " c"1Gr,, 6 1) 2`I (Dc. 4 dvoptiNS rev^ 1 - ed �¢v Vov o1.lgle lecl jev c I'too LSxSx "( c0NA11. iu Load,N j Al 01.1.11-Q. 1 -e _ �C )4 / 744 = 7Z _ z 1, � z _ �1 j�1 o1\lrNl� tie l �t■. +Ik 1�'n W� 1S.Z xtZ,a '�(3t�. _ 4 '„' Ib• J 7 Z 5 = al - . 7 x(2.5 iu >(b.2-S 1N > = a. 0245G t,� Cole I-P.1 1s ' FyS - 3Co C ) t6 /i►JZ N. 0.0' 2-bG 1tJ = 10 21 (p1l, Ina Ib 11 k In-! 7 Mi-t_ F .-AIV . CtV O Ni a r\Idt - 1,e = w 1 -1 s Z `k/ P+ " /, 2 , N " S 11 = 2� .cej b fl v 7 ^ ` ). CO i-.)_)7.&"%12.- i-.)_)7.&"%12.- Atv ritF- lE 7' a ' v4 V u 17 v A = ` boo psi X 0.Gb7S 1►al = 3`i tT S ``t Vu = 0.1S 39tr,:'= �`l`lo(» > vn ✓ lb sheet no job no. Consulting Engineers 1601 5th Avenue, Suite 1600 Seattle, WA 98101 (206) 622 -5822 Fax (206) 622 -8130 pro /6E- y Scr &, GvACc location client DE V,\ t A : C t'u C0 4 by T date 2/ 2-9 /08 sheet no. job no. f -L CI Z et 4,3 aoti'") BEAM ® 4 e' 0" /d U EV. ( Cam �Sn . a s ( , EAR 1•..I E40-1 CELL VERr REINF. 1LT1 t VSO APIAEVVE E>< 41 - feszct . tf . r . tT CLex a t o" 1.6 C CUUNNI- rYP ' 1JEL CNu Fut.LY C7RoUtT A u. (F Ex cmu Ta E D }7.1 77g.OLTS Gc �x Foo i Consulting Engineers 1601 5th Avenue, Suite 1600 Seattle, WA 98101 (206) 622 -5822 Fax (206) 622 -8130 project 1C,E - y S C 11JAkt.. location client DE `ntL V3 • ( Kict g by ) ( . 1 7 date 2 /2 5 1( / O ('j sheet no. job no. C ue.tce.C1- 1`-(.mU'J2.Y : A\ c ow 2`re" 2 MASONV U �t►0► h sl c. or•.r j wt\k,. XS C90 W v'K T 1 / AA C\Vev a y I e 01,A %&)\/t S av e 1 jk., -, ■S(...)0 ` 'St , ASW%" . \ e S. .V.a l'_; c, ,,,,,1 c.01- • s' e.►., )3+\ (-) P c''., * \Scup li t . cottcv.e-A-e M a su t.lv n 1,.., G I l S c\&a. I - v e u.1-(w c.e 8 as sV.k ou,04, lS'....1 "Wt e. FA <\ 1,1, co- ci c1e kx i k l■ja11s \\.,<,1' 1x- ',.1tc\ 2., u4e_zA UNite , ..10 \ G Nvwt:`C. M U I.Q A1 S l`- t Il', 1 (�Rc>� 1 . C Sall c 4o 1SC `sec ? ,.9 2103.12. C7 c A l ,\ a Cv uvr� Tc� 1 yv AuN Sped -cic lU1JS UT \6C T 21c..,3 50rlck Skal\ V "An a11 lot. Nuvf3 <c�N�u,1.�1 ti q rev 1 c a,•` s 1a1■S s\,,G l L M ASOt' 1 2.Y Cll..>Ll All looK.,c4 69 -' 1 " —A A, N.ks U evw \ot t ,' �c\ �cU n,1�1 >nt f Iae sc.cuv el� rl cs GENIE WA. •JUTES Gti•a� s \no1\ CGNt'ryv ( .-4 .l'•U Il?`++ S'cC � L.JU3 t1. r- 1CAI1..4kANA I -h• 1 cY .) A1\ eels s \40,l1 be TU IRC seri 103•I3. De tn. cl INSPECT l0.1 SC.H<< 2cxo6 ►ac SECT' OM 109 4 C% WIZ la 1'► `3F IC1AL EsrAP SHED PEQ IT1=1■-.1 CUAI 1i4UOUS 1 N SPECrt Um PFRtulsle 1 Aas PCCTt c)N Ge.)neMe k." TS C0 >�,I,u �crzl..tc j- PIa�,.�N v X. �RUcTU ZAt 1\-4 AsoNQ� X x Co.,. Si.xco.l %t4spec-klutV * re t'.)'ta, ma - aSQ'.Ivy Ska 11 be. bey *W- Level t six cla l Ir.I.Spec t ot.1 fCtutvt .MxtJ}S 11.4 1SC Tal1 -f, 11O`{.S.1 "C , Norl e wAlo,\ Sac 1 I% i1PS 1e (oc CAA rQN cy CGAC_gdV S 1,1\ 0% v Consulting Engineers 1601 5th Avenue, Suite 1600 Seattle, WA 98101 (206) 622 -5822 Fax (206) 622 -8130 project 1C,E - y S C 11JAkt.. location client DE `ntL V3 • ( Kict g by ) ( . 1 7 date 2 /2 5 1( / O ('j sheet no. job no. C ue.tce.C1- 1`-(.mU'J2.Y : A\ c ow 2`re" 2 MASONV U �t►0► h sl c. or•.r j wt\k,. XS C90 W v'K T 1 / AA C\Vev a y I e 01,A %&)\/t S av e 1 jk., -, ■S(...)0 ` 'St , ASW%" . \ e S. .V.a l'_; c, ,,,,,1 c.01- • s' e.►., )3+\ (-) P c''., * \Scup li t . cottcv.e-A-e M a su t.lv n 1,.., G I l S c\&a. I - v e u.1-(w c.e 8 as sV.k ou,04, lS'....1 "Wt e. FA <\ 1,1, co- ci c1e kx i k l■ja11s \\.,<,1' 1x- ',.1tc\ 2., u4e_zA UNite , ..10 \ G Nvwt:`C. M U I.Q A1 S l`- t Il', 1 (�Rc>� 1 . C Sall c 4o 1SC `sec ? ,.9 2103.12. C7 c A l ,\ a Cv uvr� Tc� 1 yv AuN Sped -cic lU1JS UT \6C T 21c..,3 50rlck Skal\ V "An a11 lot. Nuvf3 <c�N�u,1.�1 ti q rev 1 c a,•` s 1a1■S s\,,G l L M ASOt' 1 2.Y Cll..>Ll All looK.,c4 69 -' 1 " —A A, N.ks U evw \ot t ,' �c\ �cU n,1�1 >nt f Iae sc.cuv el� rl cs GENIE WA. •JUTES Gti•a� s \no1\ CGNt'ryv ( .-4 .l'•U Il?`++ S'cC � L.JU3 t1. r- 1CAI1..4kANA I -h• 1 cY .) A1\ eels s \40,l1 be TU IRC seri 103•I3. De tn. cl TAG QTY. SIZE FRAME VARIATIONS A* -WIDE B* -HIGH PROJECT LOCATION ARCH.JENGR. CONTRACTOR REPRESENTATIVE DATE ALE( MAR 0 v 3900 Dr. Greaves Rd. FILE CQ ` -; 17.7n7, anti omnissikns. 4 ' Kansas City, MO 64030 - • ••(816) 761)747 1 •) *Pis ELF6375DX and ELF6375DXH DRAINABLE STATIONARY LOUVERS 0,tic6 EXTRUDED ALUMINUM LOUVER STANDARD CONSTRUCTION FRAME 6" (152) deep, 606375 extruded aluminum. ELF6375DX 1 - .081' (2.1) nominal wall thickness. ELF6375DXH - .125" (3.2) nomi- nal wall thickness. Downspou:s and caulk- ing surfaces provided. BLADES 6063T5 extruded aluminum. ELF6375DX - .081" (2.1) nominal wall thickness. ELF6375DXH - .125' (3,2) nom- inal wall thickness. Drainabie blades are positioned at at 37 angle and spaced approximately 5 (150) center to center. SCREEN 3/4" x .051' (19 x 1.3) expanded, Flattened aluminum bird screen in removable frarne. Screen adds approximately 'I " (13) to lou- ver depth. FINISH Mill. MINIMUM SIZE 12'w x 12 "h (305 x 305). APPROXIMATE SHIPPING WEIGHT ELF6375DX 4 lbs. /ft,' (19,5 kg /m') ELF6375DXH - 6 lbs. /ft.' (29.3kg /m') MAXIMUM FACTORY ASSEMBLY SIZE Shall be 75 sq. ft (7m1 per section, not to exceed 120'w x 90'h (3048 x 2286) or 90'w x 120'h (2286 x 3048). Louvers larger than the maximum factory assembly size will require field assembly of smaller sections. SUPPORTS Louvers may be provided with :ear mounted blade supports that increase overall louver depth depending on louver size, assembly configuration or windload, Consult Ruskin for additional information. Spec ELF6375DX /ELF6375DXH.5971Replaces EF637SDX.296 CORRECTION LTR #. 5" Varies Dimensions in inches parenthesis ( ) indicate millimeters, (152) Bird Screen VARIATIONS Variations to the basic design of these louvers are available at additional cost They include: • Extended sill. • Hinged frame, • Front or rear security bars. • Filter racks. • A variety of bird and insect screens. • Selection of finishes: prime coat, baked enamel (modified fluoropolymer). epoxy. Acrodize, Kynar, clear and color anodize. (Some variation in anodize color consistency is possible.) Consult Ruskin for other special requirements. FRAME CONSTRUCTION 1_ 11h" (38) CODE � ED FOR AP PROVED COVED MAR 2 0 2008 FEATURES The ELF6375DX and ELF6375DXH offers: • 57% Free Area. • Published performance ratings based on testing in accordance with AMCA Publica- tion 511. • High performance frame system with drain - able head collects and removes water to provide excellent water penetration perfor- mance. • Drain gutter in each blade minimizes water cascade between blades. • Architecturally styled, hidden mullions allow- ing continuous line appearance up to 120" (3048). • Aluminum construction for low maintenance and high resistance to corrosion. • All welded construction. 1" (25) STANDARD INTEGRAL FLANGE 'Units furnished 1 /4' (6) smaller than given opening dimensions. ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. DOSOMS VED 2008 °Rusk' VOW IrCENTEI- 1 SUGGESTED SPECIFICATION Furnish and install louvers as hereinafter specified where shown on plans or as described in schedules. Louvers shall be stationary drainable type with drain gutters in each blade and downspouts in jambs and mullions. Louvers shall have a minimum of 57% free area based on a 48" wide x 48" high (1219 x 1219) size. Stationary drainable blades shall be contained within a 6" (152) frame. Louver components (heads, jambs, sills, blades, & mullions) shall be fac- tory assembled by the louver manufacturer. Louver sizes too large for shipping shall be built up by the contractor from factory assem- bled louver sections to provide overall sizes required. Louver design shall limit span between visible mullions to 10 feet (3) and shall incorporate structural supports required to withstand a wind - load of 20 lbs. per sq. ft. (.96kPa) (equivalent of a 90 mph wind (145 KPH] wind — specifier may substitute any loading required). PERFORMANCE DATA AMCA Standard 500 provides a reasonable basis for testing and rating louvers, Testing to AMCA 500 is performed under a certain set of laboratory conditions. This does not guarantee that other conditions will not occur in the actual environment where louvers must operate. WATER PENETRATION Test size 48" wide x48" high (1219 x 1219) Beginning point of water penetration at .01 oz./sq. ft. is 1023 fpm (312 m /min). 0.3 (3.23) a l i 0.25 (2.69) O1 d 1 t1. w.. • 0.2 • (2.15) G 0) '- �v -c s fl N w 0.15 (../ " (1.61) c of C ▪ .- 0.1 (1.09) at ni IV O 0.05 (.54) 0 900 (274) Louvers shall be Ruskin Model ELF6375DX or ELF6375DXH extruded 606375 aluminum construction as follows: Frame: 6" (152) deep. ELF6375DX - .081" (2.1) nominal wall thickness. ELF6375DXH . ,125" (3.2) nominal wall thickness. Blades: ELF6375DX - .081" (2.1) nominal wall thickness. ELF6375DXH - .125" (3.2) nominal wall thickness. Drainable blades are positioned at 37 angle and spaced approximately 5 (150) center to center. Screen: 3 /4" x .051" (19 x 1.3) expanded, flattened aluminum in removable frame. Finish: Select finish specification from Ruskin Finishes Brochure. Published louver performance data bearing the AMCA Certified Ratings Seal for Air Performance & Water Penetration must be sub- mitted for approval prior to fabrication and must demonstrate pres- sure drop and water penetration equal to or less than the Ruskin model specified. The louver system should be designed with a reasonable safety factor for louver performance. To ensure protection from water carryover, design with a performance level somewhat below maxi- mum desired pressure drop and .01 oz. /sq. ft. of water penetration. 1000 (305) 1100 (335) 1200 (366) Free Area Velocity in feet and (meters) per minute Standard air .075 lb/ft' 1300 (396) 1400 (427) 32) 78) 24) 1I) 02) .. 12 0.30 18 0.46 24 0.61 30 0.76 36 0,91 42 1,07 48 1.22 54 1.37 60 1.52 66 1.68 72 1.83 78 1.98 84 2.13 90 2.29 96 2.44 102 2.59 108 2.74 114 2.90 120 3.05 12 0.31 0,49 0.67 0.86 1.04 1.22 1.41 1.59 1.77 1.96 2.14 2.32 2.51 2.69 2.88 3.06 3.25 3,43 3.61 0.30 0.03 0.05 0.06 0.08 0.10 0.11 0.13 0.15 0.16 0.18 0.20 0.22 0.23 0.25 0.27 0.28 0.30 0.32 0.34 18 0.58 0.93 1.28 1.63 1.98 2.32 2.68 3.03 3.37 3.73 4.08 4.42 4.77 5.13 5.48 5.82 6.18 6.52 6.87' 0.46 0.05 0.09 0.12 0.15 0,18 0.22 0,25 0.28 0,31 0.35 0.38 0.41 0.44 0.48 0.51 0.54 0.57 0.61 0.64 24 0.86 1.38 1.89 2.40 2,92 3.43 3.96 4.47 4.98 5.50 6.02 6.53 7.05 7.57 8.09 8.60 9.12 9.63 10.15 0.61 0.08 0.13 0.18 0.22 0.27 0.32 0.37 0.42 0.46 0.51 0.56 0.61 0.66 0.70 0.75 0.80 0.85 0.89 0,94 30 1.14 1.82 2.50 3.18 3.87 4.54 5.24 5.92 6.59 7,28 7.97 8.64 9.33 10.01 10,70 11.37 12.06 12.74 13.42 0.76 0.11 0.17 0.23 0.30 0.36 0.42 0,49 0.55 0.61 0.68 0.74 0.80 0.87 0.93 0.99 1.06 1.12 1.18 1.25 36 1.41 2.26 3.11 3.95 4.80 5.64 6.52 7.35 8.18 9.04 9.89 10.73 11.58 12.44 13.29 14.13 14.98 15.82 16.67 0.91 0.13 0.21 0.29 0.31 0.45 0.52 0.61 0.68 0.76 0.84 0.92 1.00 1.08 1.16 1.24 1.31 1.39 1.47 1.55 42 1.69 2.70 3.72 4.72 5.75 6.74 7.79 8.79 9.79 10.81 11.83 12.83 13.86 14.88 15.89 16.90 17.92 18.92 19.94 1.07 0.16 0.25 0.35 0.44 0.53 0.63 0.72 0.82 0.91 1.00 1,10 1.19 1.29 1.38 1.48 1.57 1.67 1.76 1.85 48 1.97 3.15 4.33 5.50 6. .... 7.86 9.08 10.24 11.40 12.59 13.78 14.95 16.14 17.33 18.51 19.68 20.87 22.04 23.23 1.2 0.18 0.29 0.40 0.51 0.62 0.73 0.84 0.95 1.06 1,17 1.28 1.39 1.50 1.61 1.72 1.83 1.94 2.05 2.16 54 2.24 3.59 4.94 6.27 7.63 8.96 10.35 11.67 13.00 14.35 15.71 17.04 18.40 19.75 21.10 22.44 23.79 25.12 26.48 1.37 0.21 0.33 0.46 0.58 0.71 0.83 0.96 1.08 1.21 1.33 1.46 1.58 1.71 1.84 1.96 2.09 2.21 2.33 2,46 60 ' 2.52 4,03 5.55 7.05 8.57 10.06 11.62 13.12 14.60 16.13 17.65 19.14 20.67 22.19 23.71 25.21 26.73 28.22 29.75 1,52 0.23 0.37 0.52 0.66 0.80 0.93 1.08 1.22 1.36 1,50 1,64 1.76 1,92 2,06 2.20 2.34 2.48 2.62 2.76 66 2.80 4.47 6.16 7.82 9.51 11.17 12.90 14.56 16,20 17.90 19.59 21.24 22.94 24.63' 26.31 27.98 29.67 31.32 33.01 1.68 0.26 0,42 0.57 0.73 0.88 1.04 1.20 1.35 1.51 1,66 1.82 1.97 2.13 2.29 2.44 2.60 2.76 2,91 3.07 72 3.08 4.92 6.76 8.59 10.45 12.27 14.18 16.00 17.61 19.67 21.53 23.35 25.21 27.07 28.91 30.74 32.60 34.42 36.28 1.83 0.29 0.46 0.63 0.80 0,97 1.14 1.32 1.49 1.66 1.83 2.00 2.17 2.34 2.52 2.69 2.86 3.03 3.20 3.37 78 3,35 5.36 7.37 9,37 11.40 13.38 15.45 17.44 19.41 21.44 23.47 25.45 27.48 29.51 31.52 33,51 35.54 37.52 39.55 1.98 0.31 0.50 0.68 0.87 1.06 1.24 1.44 10.91 1.80 1.99 2.18 2.37 2.55 2.74 2.93 3.11 3.30 3.49 3.68 84 3.63 5.60 7.98 10.14 12.34 14.48 16.73 18.88 21.02 23.21 25.41 27.55 29.75 31.94 34.12 36.28 38.48 40.62 42.82 2.13 0.34 0.54 0.74 0.94 1.15 1.35 1.00 1.75 1.95 2.16 2.36 2.56 2.76 2.97 3.17 3.37 3.58 3.77 3.98 90 3.91 8.25 8.59 10.92 13.28 15.59 18.01 20.32 22.62 24.98 27.35 29.65 32.02 34.38 36.73 39.05 41.41 43.72 46.09 2.29 0.36 0.58 0.80 1.01 1.23 1.45 1.67 1.89 2.10 2.32 2.54 2.76 2.98. 3.19 3.41 3.63 3.85 4.06 4.28 32) 78) 24) 1I) 02) .. 11111111•1111111V III MODE 4 EXHAUST INTAKE: MODE 54) 20) 03) 7e) 52) 271 OZ) 76) 51) 25) ' "N IN ►: m , ' r v - tvvc — (£l2 " (Eel N — (Kt 1.00 (25. .90 (22. ,80 (20. .70 (17. .60(1s. .50 (12. .40 (10. .30 (7. .20 (5. 10 (2. .09 (2. .06 (2. .0711 .06 (1. .05 (1. .04 (1, .03 ). 02 ). 01 (. FREE AREA GUIDE Free Area Guide shows free area in ft' and m for various sizes of ELF6375DX and ELF6375DXH. Width - Inches and Meters PRESSURE DROP °. 8 8 8 82888 8 8 8 08888 W VI o f m Air Velocity in feet and (meters) per minute through Free Area Ratings do not include the effect of a bird screen. mostmtnl nnocamnot n550CI000n.InC. amca comma RmufG$ Ruskin Manufacturing Company certifies that the ELF6375DX and ELF6375DXH Louvers shown herein is licensed to bear the AMCA Seal, The ratings shown are based on tests and procedures per- formed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings and water penetration ratings only. Height — Inches and Meters TYPICAL INSTALLATION DETAILS CMU Louver — — Extended Sill � ��sonry Wall Wood Installation RUSKIN® 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761.7476 FAX (816) 7658955 Metal Panel Drip Cap Insulatlo Extended Sill Integral Flange Frame Louver Fastener (by others) Louver CMU Metal Panel Wail Flange Mount a A • Accessories at additional cost. 94 Hollow-SW Dm M; Concrete, Block, Brick, Precast Hollow Core Plank, Stone g .**fl,b1W i;#46 1/4" to 5/8" 1.$';7tgaT4. : Zamac Alloy with Carbon Steel or Stainless Steel Cones PRODUCT DESCRIPTION ; 4: - The Hollow-Set Dropin anchor is designed for anthoring in hollow base materials such as hollow concrete block, brick with weep holes, and hollow core pre-cast concrete plank It can also be used in solid base materials making it a problem solving universal anchor Hollow base materials such as precast plank or C-90 Block often have a maximum outer wall tideless of 1-1/2" During the drilling process, spelling on the back side of the wall as the bit penetrates into the hollow portion of the base material often decreases the wall tideless available for anchoring to 1 or less This creates a problem for most ainventional style anchors which will not function properly in materials of this thickness The design of the Hollow-Set Dropin overcomes this problem FMRC and UL listrogs make this anchor appropriate for overhead applications ?”-Zat'Mlr, !/4 °Copoidt in Drill a hole into the base material to the required depth In hollow base materials, drill through into the cell or void The tolerances of the drill bit used should meet the requirements of ANSI Standard 827215 Blow the hale clean of dust and other material Do not expand the anchor prior to installation Insert cone end and tap flush to Surface Position fixture, insert bolt and tighten The bolt should engage a minimum of 2/3 of the anchor threads The anchor can also be expanded using a Holbw-Set Tool f Hollow Tool is used, thread anchor onto tool prior to tapping into anchor hole When flush with surface, turn tool clockwise to tighten Release tool from set anchor by turning counterclockwise fixture can then be attached INSTALLATION PROCEDURES e Ai.i.ws:;:liVit'NY'*11:131:3StAe'AN'trat.M.;:lV'IVATill'Af.:4117r:vi4 Blow the hole dean of dust and other matenal insert the anchor into the hole Position the setting tool in the U anchor Drill a hole into the base material to the required depth The tolerances of the drill bit used should meet the requirements of ANSI Standard 8212 15 Using the Solid Tool, set the anchor by driving the Zamac sleeve over tire cone using several sharp hammer blows Be sure the anchor is at the required embedment depth so that anchor threads do not protnide above the surface of the base material Position the fixture, insert bolt or threaded rod and tighten AJCHOR SIZES To select the proper minimum length bolt. determine the thickness of the fixture including any spacers or shims Add this to the depth required to engage at least 2/3 of the threads in the cone r4 CC N ciegpM - Oki i•a• dtWf • • WZ 9320 9330 9340 9350 9360 9420 Hallow Tool Solid Tool Solid Setting Tool 1/4" 5/16" 9440 3/8" 1/2'' 5/8" Hallam Setting Tool (also for Saki Settiq 3/8" 5/8' 5/8" 3/4" 1" 7/8" 5/8 1-5/16" 15/16" 1-5/16" 15/16" 1-3/4" 1-114" 2" 1-1/2" IWfre -0 _19.:MiS2E'SHEOEWFM , 9323 9333 9343 100 100 100 100 100 9353 1000 1-3/4 500 5-1/2 500 5-1/2 100 9.1/2 100 21 'VW* Aricviorvr.".*AtI„IT,‘, v.>,* , m4sktrz. - , - .6 n 4 K,s° 9363 9322 9332 9342 9352 9362 e i • we.. • 3 at • 4 'X • • • 4 • INSTALLATION SPECIFICATIONS tnR. - aS14t4.W ndf:::�'i,.41,.c , 4-*": ANSI Drill Bit Size 3/8" Max Torque (ft. -Ibs.) 5 Thread Size 1/4 -20 Thread Length 3/8" in cone MATERIAL SPECIFICATIONS ;riciioR�r �:7 4o ? tx ursww>B? t 5341 Anchor Body Cone Plating (Cone) P.ERFORMANCE DATA. "'- The following ultimate load capacities are based on testing conducted according to ASTM Standard E 488 inkrsPEONGRL' err- 4acri "CO rC pat.. �10ik'PSrC@r'>:RETE N 6T0! 4Ya psH ttl.4 � yiSteEa1E - t1r 14' R �kH s_T 84S) h , kut41 „Put - tL N,,, ,JLe5t 1/4 1/4 5/16 5/16 5/16 3/8 3/8 3/8 1/2 1/2 5/8 1/4 5/16 3/8 3/8 1/2 5/8 1/4" 5/16" 3/8" 1/2" 5/8" 3/8 3/8 5/8 5/8 5/8 5/8 5/8 5/8 3/4 3/4 1 3/4 7/8 3/4 1 1 -1/2 3/4 1 1 -1/2 1 -1/2 2 2 -1/4 NOTE. The values fisted abote are ultimate load capacities which should be refixed by minimum safety factor of 4 or greater to detemune the allowable working toad 3/8 5/8 5/8 5/8 3/4 1 Zamac Alloy AISI 12L14 ASTM 6633, SC1, Type III (Fear 5) 760 1,000 840 1,120 2,710 960 1,370 3.010 2,140 3,420 5,725 ' Anchors wee installed with sleeve flush to seam of the plank '' Anchors mere installed in sokIportion of plank in ardor holes that did not spell into holkw cavity ;1111Zi^late[6aQ.r a s:'c.pO9ioc5ANpsoup-1304 $:+ '7/8" '1 -1/2" '1 -1/2" , 1.1/2 .. - 1.1/2" 5/8" 7 5/16.18 5/8" 1.200 1.440 1,840 1,980 2,740 2,230 2,550 3,145 4,0" 5 4,020 6,400 7/8 • 1 -1/2 • 3/4 • 1.1/2 • 1-1/2 • 1-1/2 • 5/8" 10 3/8 -16 5/8' 1,140 1,305 1,240 1,680 3,405 1,460 2,070 4,315 4,025 5,370 9,660 1,325 3.070 3450 3,580 3,580 Zamac Alloy Type 304 SS N/A 1,200 1,440 1,840 1,980 2.740 2.230 2.550 3,145 4,015 4,020 6,400 2.240 3,280 '2,525 3.620 4,660 9,660 3/4' 20 1/2 -13 3/4" 1,440 2,045 1.500 2,200 5,110 1,660 2,290 5,085 7,285 9,705 12,745 1" 4D 5/8-11 1 " 1.200 1,440 1,840 1,980 2,740 2;230 2,550 3,145 4,015 4,020 6.400 1,800 2.640 3,775 4,220 6,840 12,680 1,575 1,815 2 485 3,655 3,740 'na crt0 ; ,SdE 3, . 1/4 5/16 3/8 1/2 5/8 Rs 1/4" 5/16" 3/8' 1/2" 5/8" 2.1/2 3 -1/8 3 -3/4 5 6-1/4 1.00 2 -1/4 2.7/8 3 -3/8 4 -1/2 5 -5/8 0.90 7/8" 1 -1/2" 1 -1/2" 1 -1/2" 2 -1/4" 2 2 -1/2 3 4 5 0.80 1 -3/4 2 -1/4 2 -5/8 3-1/2 4 -3/8 0.70 880 1,460 1 860 3,240 4,680 �`EOGE UISTA�C,�:'- TENSIO �� R�3'3kSe ? • - a : � L 7 .�'�. ''7k"w;, *;a���2n e'er' =_4 ��ad� For tension loads an edge distance, E, of 12 diameters (12D) or greater should be used to obtain the maximum tension load The minimum recommended edge distance, E, is 8 diameters (8D) at which point the tension load should be reduced by 20 %. Edge distances closer or less than 8 diameters (8D) need to be field tested Actual base material conditions will determine any applicable 1,640 2,230 2,980 4,230 6,420 'Anchors were installed with sleeve flush to face shell surface NOTE. Depending upon anchor application and governing building code, Ornate bad capacities should be reduced by minim= safety factor of 4 crgreater to detcrmbe the allowable waking bad The design professional famrliarwith the actual product installation should be consulted Please refer to the general section entitled Evatzat m of Test Data that appears earlier in this manual for current ictistry standards The consistency of plank C -90 hollow block and solid red brick varies peaty The load capacities fated above should be used as guideline sonly. Job site tests should be conducted to venfy base material consistency proper installation torque values and actual anchor performance ;DESIGN "CRITEPIA *'; x/oc,9Lr 7*,ffi In solid base materials, the minimum recommended thickness of base material, BMT, when Ming the Hollow -Set Dropin is 125% of the embedment for solid materials to be used For hollow materials a minimum wall thickness of 1 -1/2" is suggested Job site tests should be performed on installations in hollow base materials -t sil ri° To obtain the maximum load in tension or shear, a spacing, S of 10 anchor diameters (1 OD) or greater should be used. The minimum recommended anchor spacing, S, is 5 anchor diameters (5D) at which point the load should be reduced by 50 %. Anchor spacing doser or less than 5 diameters (5D) needs to be field tested Actual base material conditions will determine any applicable reduction factor The following table lists the load reduction factor, Rs for each anchor diameter, D, based on the center to center anchor sparing ,$AilOitN %i ' ,,. �''" - - 'f t ;'�.1x r.r. O t5PACINgS d;Cf+Sr; '� �` s?�f"}4Fr � {SIy1t a O StitlRrt.�e'�'ti 1 -1/2 1 -1/4 1 -7/8 1 -1/2 2 -1/4 1 -7/8 3 2.1/2 3-3/4 3-1/8 0.60 0.50 WE ARE SENDING: SUBMITTED FOR: ACTION TAKEN: LT Shop Drawings/Submittals lif Approval • Approved as Submitted ❑ Letter ❑ Your Use ❑ Approved as Noted • Prints 12f As Requested • Returned After Loan ■ Change Order ■ Review and Comment • Resubmit Lo Copies for Approval • Plans • Submit 1 0 Copies for Distribution ❑ Samples SENT VIA: Mail • Returned i 0 Copies • Specifications WI Attached • Retumed for Corrections g Other: 0 • Separate Cover • Due Date: SABEY 12 201 Tukwila International Blvd Fourth Floor CONSTRUCTION Seattle, WA 98168 -5121 PROJECT: IGE-4 Microsoft Chiller Wall Upgrade DATE: 3/4/2008 TO: DB Solutions, LLC 10627 90th ST NE Lake Stevens, WA 98258 Phone: 425 - 737 -4042 Fax: 360 - 657 -0479 email: davidhbodmer @msn.com ATTN: David Bodmer ITEM COPIES DATE ITEM NUMBER C C: 0 3/4/2008 SUB 089000 -001 FILE COP Remarks: 1. Revise quantity of 51 "x84" louvers to (2). 2. Please inform Sabey of lead time. Transmittal No. 00001 nsA gnfti clYP�.�f'i1 to9..o 206/ 281 -4200 main line 206/ 281 -0920 fax line www_sabey.com DESCRIPTION REF: Submittals - Louvers Dwg: Title: Louvers and Vents Desc: Ruskin Louvers CORRECTION Rrr'r'" MAR 17 2008 PEFirvit 1 CEN T Er Signed: Joh LEED A.P f_trsns_sabey_1 Rev. sk 03105/02 JOB: CUSTOMER: SUBMITTED BY: BUSKIN Submittal Data March 4, 2008 CHILLER WALL IGE BLDG 4 D/B Solutions Air Commodities, Inc GAIL GANZER (206) 767 -2600 (206) 767 -4815 (FAX) BY. op DATE: 3 /q( S ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. SABEY CONSTRUCTION INC. 0 APPROVED - SUBMITTAL AP R O VE AS CORRECTED Q REVISE & RESUBMIT ❑ NOT APPROVED Approval is only for conformanco with tho dosign concept of the contract general . hplisuct�t with ccforinformation p given nsible for dimensions to be confirmed and correlo:cd ct the job s:to, tor Information that pertains to the fab Ica :lon p; oco s, or to the techniques of construction and for coordination cf tha work of all varies. JOSW 0-2-1- SUBMITTAL# Doi SECTION# o8gor BRAND: RUSKIN Louvers Model: ELF6375DX Deduct 1/4 Inch FRAME: FINISH TYPE: FINISH COLOR: CONSTRUCTION: WINDLOAD: QTY WIDTH HEIGHT 23 722 :4 x 48 x 36 x 114 BOX BE/50% KYNAR(B1) TO MATCH(98) STANDARD 20 ert-1 s oma a t (2) ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Air Commodities, Inc March 4, 2008 REPS v4.10.178 TAG TAG QTY. SIZE FRAME VARIATIONS A* -WIDE B* -HIGH PROJECT LOCATION ARCHJENGR. CONTRACTOR REPRESENTATIVE DATE RUSKIN® 3900 Dr. Greaves Rd. • Kansas City, MO 64030 ELF6375DX and ELF6375DXH DRAINABLE STATIONARY LOUVERS EXTRUDED ALUMINUM LOUVER STANDARD CONSTRUCTION FRAME 6" (152) deep, 6063T5 extruded aluminum. ELF6375DX 1 - ,081' (2.1) nominal wall Thickness. ELF6375DXH - .125" (3,2) nomi- nal wall thickness. Downspouts and caulk- ing surfaces provided. BLADES 6063T5 extruded aluminum. ELF6375DX - .081" (2.1) nominal wall thickness. ELF6375DXH - .125" (3.2) nom- inal wall thickness. Drainable blades are positioned at at 37 angle and spaced approximately 5 (150) center to center. SCREEN 3 /4" x .051' (19 x 1.3) expanded, fattened aluminum bird screen in removable frame. Screen adds approximately 1 /2" (13) to lou- ver depth. FINISH Mill. MINIMUM SIZE 12'w x 12 "h (305 x 305). APPROXIMATE SHIPPING WEIGHT ELF6375DX - 4 Ibs./ft.' (18.5 kg ELF6375DXH - 6 lbs./ft.' (29.3kg /m') MAXIMUM FACTORY ASSEMBLY SIZE Shall be 75 sq. ft. (7m') per section, not to exceed 120 "w x 90'h (3048 x 2286) or 90"w x 120'h (2286 x 3048). Louvers larger than the maximum factory assembly size will require field assembly of smaller sections. SUPPORTS Louvers may be provided with rear mounted blade supports that increase overall louver depth depending on lower size, assembly configuration or windtoad. Consult Ruskin for additional information. 8* Varies Dimensions in inches, parenthesis ( ) indicate millimeters. Spec ELF6375DXIELF63 75DXH- 5971Repbces :LF5375DX 299 (152) • Bird Screen (816) 761 -7476 FAX (816) 765 -8955 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. FEATURES The ELF6375DX and ELF6375DXH offers: • 57% Free Area. • Published performance ratings based on testing in accordance with AMCA Publica- tion 511. High performance frame system with drain - able head collects and removes water to provide excellent water penetration perfor- mance. Drain gutter in each blade minimizes water cascade between blades. Architecturally styled, hidden mullions allow- ing continuous line appearance up to 120" (3048). • Aluminum construction for low maintenance and high resistance to corrosion. • 'All welded construction. VARIATIONS Variations to the basic design of these louvers are available at additional cosL They include: • Extended sill. • Hinged frame. • Front or rear security bars. • Filter racks. • A variety of bird and insect screens. • Selection of finishes: prime coat, baked enamel (modified fluoropolymer). epoxy. Acrodize, Kynar, clear and color anodize. (Some variation In anodize color consistency Is possible.) Consult Ruskin for other special requirements. FRAME CONSTRUCTION STANDARD INTEGRAL FLANGE 'Units furnished 1 /4' (6) smaller than given opening dimensions. o Ruskin Manufacturing 1997 SUGGESTED SPECIFICATION Furnish and install louvers as hereinafter specified where shown on plans or as described in schedules. Louvers shall be stationary drainable type with drain gutters in each blade and downspouts in jambs and mullions. Louvers shall have a minirnum of 57% free area based on a 48" wide x 48" high (1219 x 1219) size. Stationary drainable blades shall be contained within a 6" (152) frame. Louver components (heads, jambs, sills, blades, & mullions) shall be fac- tory assembled by the louver manufacturer. Louver sizes too large for shipping shall be built up by the contractor from factory assem- bled louver sections to provide overall sizes required. Louver design shall limit span between visible mullions to 10 feet (3) and shall incorporate structural supports required to withstand a wind- load of 20 lbs. per sq. ft. (.96kPa) (equivalent of a 90 mph wind 1145 KPH] wind — specifier may substitute any loading required). PERFORMANCE DATA AMCA Standard 500 provides a reasonable basis for testing and rating louvers. Testing to AMCA 500 is performed under a certain set of laboratory conditions. This does not guarantee that other conditions will not occur in the actual environment where lowers must operate. WATER PENETRATION Test size 48" wide x 48" high (1219 x 1219) Beginning point of water penetration at .01 oz./sq. ft. is 1023 fpm (312 m /min). 0.3 (3.23) 03 0.25 • (2.69) 0) 0) • 0.2 (2.15) E� 0 E Il u 4 " (1.61) C = 7 g -0 rt) e r 0.1 a� is 4 Q 0.05 (.54) 0.15 0 900 1000 1100 (274) (3(15) (335) Free Area Velocity in feet and (meters) per minute Standard air .075 lb/ft' Louvers shall be Ruskin Model ELF6375DX or ELF6375DXH extruded 6063T5 aluminum construction as follows: 6" (152) deep. ELF6375DX - .081" (2.1) nominal wall thickness. ELF6375DXH - ,125' (3.2) nominal wall thickness. Blades: ELF6375DX - .081" (2.1) nominal wall thickness. ELF6375DXH - .125" (3.2) nominal wall thickness. Drainable blades are positioned at 37 angle and spaced approximately 5� (150) center to center. Screen: 3/4" x .051' (19 x 1.3) expanded, Flattened aluminum in removable frame. Finish: Select finish specification from Ruskin Finishes Brochure. Published louver performance data bearing the AMCA Certified Ratings Seal for Air Performance & Water Penetration must be sub- mitted for approval prior to fabrication and must demonstrate pres- sure drop and water penetration equal to or less than the Ruskin model specified. Frame: The louver system should be designed with a reasonable`' safety factor for louver performance. To ensure protection from water carryover, design with a performance level somewhat below maxi- mum desired pressure drop and .01 oz. /sq. ft, of water penetration. 1200 (366) 1300 (396) 1400 (427) 1.00 (25.40) .90 (22.66) .80 (20.32) .70 (17.78) .80 (15.24) .50 (12.70) .40 (1 0.16) .30 (7.62) .20 (5.066) 10 (2.54) .09 (2.29) .08 (2.03) .07 (1.78) .06 (1.52) .05 (1.27) .04 (1.02) 03 (.76) .02 (.51) .01 (.25) FREE AREA GUIDE Free Area Guide shows free area i ft and mz for various sizes of ELF6375DX and ELF6375DXH, Width - Inches and Meters PRESSURE DROP O op N p A c�No °o °o o° °o o b I� 00 01 C Air Velocity in feet and (meters) per minute through Free Area Ratings do not include the effect of a bird screen. ma, nnocomaoI associauon.mc. amca CERTIFIED RRflfieS Ruskin Manufacturing Company certifies that the ELF6375DX and ELF6375DXH Louvers shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures per- formed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings and water penetration ratings only. Static Pressure Drop in Inches w.g. and (mm) Height — Inches and Meters 12 0.30 18 24 0.46 0.61 30 0.76 36 0.91 42 1.07 48 1.22 54 1.37 60 1.52 66 1.68 72 1.83 78 1,98 84 2.13 90 2.29 96 2.44 102 2.59 108 2.74 114 2.90 120 3.05 12 0.31 0.49 0.67 0.86 1.04 1.22 1.41 1.59 1.77 1.98 2.14 2.32 2.51 2.69 2.88 3.06 3.25 3.43 3.61 0.30 0.03 0.05 0.06 0.08 0.10 0.11 0.13 0.15 0.16 0.18 0.20 0.22 0.23 0.25 0.27 0.28 0.30 0.32 0.34 18 0.58 0.93 1.28 1.63 1.98 2.32 2.68 3.03 3.37 3.73 4.08 4.42 4.77 5.13 5.48 5.82 6.18 6.52 6.87 0.46 0.05 0.09 0.12 0.15 0.18 0.22 0.25 0.28 0.31 0.35 0.38 0.41 0.44 0.46 0.51 0.54 0.57 0.61 0.64 24 0:86 1.38 1.89 2.40 2.92 3.43 3.96 4.47 4.98 5.50 6.02 6.53 7.05 7.57 8.09 8.60 9.12 9.63 10.15 0.61 0.08 0.13 0.18 0.22 0.27 0.32 0.37 0.42 0.46 0.51 0.56 0.61 0.66 0.70 0.75 0.80 0.85 0,89 0,94 30 1.14 1.82 2.50 3.18 3.87 4.54 5.24 5.92 6.59 7.28 7.97 8.64 9.33 10.01 10.70 11.37 12.08 12.74 13.42 0.76 0.11 0.17 0.23 0.30 0.36 0.42 0.49 0.55 0.61 0.68 0.74 0.80 0.87 0.93 0.99 1.06 1.12 1.18 1.25 36 1.41 2.26 3.11 3.95 4.80 5.64 6.52 7.35 8.18 9.04 9.89 10.73 11.58 12.44 13.29 14.13 14.98 15.82 16.67 0.91 0.13 0.21 0.29 0.37 0.45 0,52 0.61 0,68 0.76 0.84 0,92 1.00 1.08 1.16 1.24 1.31 1.39 1.47 1,55 42 1,69 2.70 3.72 4.7: 1.75 6.74 7.79 8.79 9.79 10.81 11.63 12.83 13.86 14.88 15.89 16.90 17.92 18.92 19.94 1.07 0.16 0.25 0.35 0.44 0.53 0.63 0.72 0.82 0.91 1.00 1.10 1.19 1.29 1.38 1.48 1.57 1.67 1.76 1.85 48 1.97 3.15 4.33 5.50 6.69 7.86 9.08 10.24 11.40 12.59 13.78 14.95 16.14 17.33 18.51 19.68 20.87 22.04 23.23 1.2 0.18 029 0.40 0.51 0.62 0.73 0.84 0.95 1.06 1.17 1.28 1.39 1.50 1.61 1.72 1.83 1.94 2.05 2.16 54 2.24 3.59 4.94 6.27 7.63' 8.96 10.35 11.67 13.00 14.35 15,71 17.04 18.40 19.75 21.10 22.44 23.79 25.12 26.48 1.37 0.21 0,33 0.46 0.58 0,71 0.83 0.96 1.08 1.21 1.33 1.46 1.58 1.71 1.84 1.96 2.09 2.21 2.33 2.46 60 ' 2.52 4.03 5.55 7.05 8.57 10.06 11.62 13.12 14.60 16.13 17.65' 19.14 20.67 22.19 23.71 25.21 26.73 28.22 29.75 1.52 0.23 0.37 0.52 0,66 0.80 0.93 1.08 1.22 1.36 1.50 1,64 1,78 1,92 2.06 2.20 2.34 2.48 2.62 2.76 66 2.80 4.47 6.16 7.82 9.51 11.17 12.90 14.56 16.20 17.90 19.59 21.24 22.94 24.83 26.31 27.98 29.67 31.32 33.01 1.68 0.26 0.42 0.57 0.73 0.88 1.04 1.20 1,35 1.51 1.66 1.82 1.97 2.13 2.29 2.44 2.60 2.76 2.91 3.07 72 3.08 4.92 6.76 8.59 10.45 12.27 14.18 16.00 17.81 19.67 21.53 23.35 25.21 27.07 28.91 30.74 32.60 34.42 36.28 1.83 0.29 0.46 0.63 0.80 0.97 1.14 1.32 1.49 1.66 1.83 2.00 2.17 2.34 2.52 2.69 2.86 3.03 3.20 3.37 78 3.35 5.36 7.37 9.37 11.40 13.38 15.45 17.44 19.41 21.44 23.47 25.45 27.48 29,51 3t52 33.51 35.54 37.52 39.55 1.98 0.31 0,50 0.68 0,67 1.06 1.24 1.44 10.91 1.80 1.99 2.18 2.37 2.55 2.74 2.93 3.11 3.30 3.49 3.68 84 3.63 5.80 7.98 10.14 12.34 14.48 16.73 18.88 21.02 23.21 25.41 27.55 29.75 31.94 34.12 36.28 38.48 40.62 42.82 2,13 0.34 0.54 0.74 0.94 1.15 1.35 1.00 1.75 1.95 2.16 2.36 2.56 2.76 2.97 3.17 3.37 3.58 3,77 3.98 90 3.91 8.25 8.59 10.92 13.28 15.59 18.01 20.32 22.62 24.98 27.35 29.65 32.02 34.38 38.73 39.05 41.41 43.72 46.09 2.29 0.36 0.58 0.80 1.01 1.23 1.45 1.67 1.89 2.10 2.32 2.54 2.76 2.98 3.19 3.41 3.63 3.85 4.06 4.28 1.00 (25.40) .90 (22.66) .80 (20.32) .70 (17.78) .80 (15.24) .50 (12.70) .40 (1 0.16) .30 (7.62) .20 (5.066) 10 (2.54) .09 (2.29) .08 (2.03) .07 (1.78) .06 (1.52) .05 (1.27) .04 (1.02) 03 (.76) .02 (.51) .01 (.25) FREE AREA GUIDE Free Area Guide shows free area i ft and mz for various sizes of ELF6375DX and ELF6375DXH, Width - Inches and Meters PRESSURE DROP O op N p A c�No °o °o o° °o o b I� 00 01 C Air Velocity in feet and (meters) per minute through Free Area Ratings do not include the effect of a bird screen. ma, nnocomaoI associauon.mc. amca CERTIFIED RRflfieS Ruskin Manufacturing Company certifies that the ELF6375DX and ELF6375DXH Louvers shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures per- formed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings and water penetration ratings only. Static Pressure Drop in Inches w.g. and (mm) Height — Inches and Meters III ` /', a INTAKE MODE EXHAUST MODE r 1 V. 0 `. v 17 UM (E1.2 O 0 6 S "4 CI - (1£1 1.00 (25.40) .90 (22.66) .80 (20.32) .70 (17.78) .80 (15.24) .50 (12.70) .40 (1 0.16) .30 (7.62) .20 (5.066) 10 (2.54) .09 (2.29) .08 (2.03) .07 (1.78) .06 (1.52) .05 (1.27) .04 (1.02) 03 (.76) .02 (.51) .01 (.25) FREE AREA GUIDE Free Area Guide shows free area i ft and mz for various sizes of ELF6375DX and ELF6375DXH, Width - Inches and Meters PRESSURE DROP O op N p A c�No °o °o o° °o o b I� 00 01 C Air Velocity in feet and (meters) per minute through Free Area Ratings do not include the effect of a bird screen. ma, nnocomaoI associauon.mc. amca CERTIFIED RRflfieS Ruskin Manufacturing Company certifies that the ELF6375DX and ELF6375DXH Louvers shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures per- formed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings and water penetration ratings only. Static Pressure Drop in Inches w.g. and (mm) Height — Inches and Meters TYPICAL INSTALLATION DETAILS CMU Louver Extended SIII � Wall Wood Installation RUSKIN® 3900 Dr. Greaves Rd Kansas City, MO 64030 (816) 761 -7476 FAX (816) 765 -8955 Metal Panel Insulatlo Drip Cap Extended SHII Integral Flange Frame Louver Fastener (by others) Louver +v ..• ,• . •'! ... • • .. y. tip+ A 4,' CMU Metal Panel Wall Flange Mount Accessories at additional cost. TYPICAL INSTALLATION DETAILS Flange Mount UNITED ENERTECH CORPORATION Anglo Sublrame 3005 South Hickory Street Chattanooga, TN 37407 (423) 698 -7715 Fax (423) 898-6829 www.unitedenertech.corn Metal Panel Wall Wood Installation Acsasawtes at add bcnat cost Suggested are (2) 7R1T diameter boles and t2) ltOr Stir aala.ra. screws for angle Ito louver. Nct by UE Holes for att+onmlat to wall caoditions Mind In !Mt by customs. Anchors for your specific InstsiaUoe not soppaed byUE To pnrant =melon, apply heavy coating sulfas, In � with paid ccoa a, any masonry, of dissimilar metals. 94 HoIBow-Ser Dro s to Coo ' nadir OII Concrete, Block, Brick Precast Hollow Care Plank, Stone 1/4" t 518" [g iM 7typy�P Zamac Alloy with Carbon Steel or Stainless Steel Cones .PRODUCT: DESCRIPTION ' v << The Hollow -Set Dropin anchor is designed for anchoring in hollow base materials such as hollow concrete block, brick with weep holes, and hollow core pre -cast concrete plank It can also be used in solid base materials making it a problem solving universal anchor Hollow base materials such as precast plank or C -SO Block often have a maximum outer wall thickness of 1 -1/2 ". During the chilling process, spelling on the back side of the wall as the bit penetrates into the hollow portion of the base material often decreases the wall thickness available for anchoring to 1" or Is This creates a problem for most conventional style anchors which will not function properly in materials of this thickness The design of the Hollow -Set Dropin overcomes this problem FMRC and UL listings make this anchor appropriate fa overhead applications INSTALLATION.PROCEDURES { ? 4 Drill hole into the base material to the required depth. 61 hollow base matedat,, drill through into the cell or void The tolerances of the drill bit used should meet the requirements of ANSI Standard 821215 Blow the hole dean of dust and other material Do not expand the anchor prior to installation Insert cone end and tap flush to surface Position fixture, insert bolt and tighten The bolt should engage a minimum of 2/3 of the anchor threads The anchor can also be expanded using a Hollow -Set Tool If Hollow Tool is used thread anchor onto tool prior to tapping into anchor hole When flush with surface, turn tool clockwise to tighten Release tool from set anchor by turning counterclockwise fixture can tten be attached -INSTALLATION :PROCEDURES: ;t aS;B.(Q'BCLy .D f • 9320 9330 9340 9350 9360 Hollow Tool Solid Tool Send Setting rod Blow the hole dean of dust and other material truert a the anchor into the hole. Position the setting tool in the U anchor. t =t 9420 • •A f • D f ',ANCHOR To select the proper minimum length bolt, determine the thickness of the fixture including any spacers or shims Add this to the depth required to engage at least 2/3 of the threads in the cone 'CAT ti c9: ID _ WV 1tt ,....,, 1/4" /4 5/16" 9440 3/8' 1/2" 5/8" Drill a hole into the base material to the required depth The tolerances of the drill bit used should meet the requirements of ANSI Standard B212 15 Using the Solid Tool, set the anchor by driving the Zamac sleeve over the cone usingseweral sharp hammer blows Be sure the anchor is at the required embedment depth, so that anchor threads do not protrude above the surface of the base material Position the fixture, insert bolt or threaded rod and tighten 7/8" 1 -5/16" 1 -5 /16" 3/4" 1 -3/4' 1" 2" 3/8" 5%8" 5 /8" rq 4 9323 9333 9322- • 9332 HdrowSemng Tool (also forSokd Setting) 5/8' 15/16" 15/16" 1 -1/4" 1 -1/2" 100 1000 1 -3/4 100 sdo 5-1/2 100 500 5 -1/2 100 100 1:9 100 100 21 9343 9353 9363 9342 9352 9362 INSTALLATION SPECIFICATIONS, _.. MATERIALISPECIFICRTIONS 'ANLftOH .' e" 4t4I i taCES - ; s�.sre�,z;T4 Anchor Body Cone Plating (Cone) PERFORMANCE DATA The following ultimate load capacities are based on testing conducted according to ASTM Standard E 488 y� g 4 �, ry�ie A f 1 9tp R 6C • -1TAARarA1Nlss.. rk 1, N_• &.afAr D-F ?� imatly. .. p t�f0 T�IY $ilctU 4.ef,6'111LLL��� TrON6LEWE«.C- dnQ'p5F4C4'CREVE tllsSi 1/4 1/4 5/16 5/16 5/16 3/8 3/8 3/8 1/2 1/2 5/8 1/4 5/16 3/8 3/8 1/2 5/8 1/4" 5/16" 3/8" 1/2" 5/8" ANSI Drill Bit Size 3/8" Max Torque (ft -lbs.) 5 Thread Size 1/4-20 Thread Length 3/8" in cone 3/8 3/8 5/8 5/8 5/8 5/8 5/8 5/8 3/4 3/4 1 Mii&"ki tcde`n 3/4 7/8 3/4 1 1 -1/2 3/4 1 1 -1/2 1 -1/2 2 2 -1/4 Zamac Alloy AISI 121.14 ASTM 8633, SC1, Type III (Fe/Zr 5) 760 1,000 840 1,120 2,710 960 1.370 3,010 2,140 3,420 5,125 5/8" 5/16-18 5/8" 1,230 1,440 1,840 1,980 2,740 2.230 2,550 3,145 4.0'5 4,020 6,400 3/8 5/8 5/8 5/8 3/4 1 "7/8" '1 -1/2" '1-1/2" '1-1/2" '1 -1/2" 7/8 • 1 -1/2 3/4 1 -1/2 • 1 -1/2 1 -1/2 5/8" 10 3/8-16 5/8' 1,140 1,305 1,240 1,680 3,405 1,460 2,070 4,315 4,025 5,370 9.660 1,325 3,070 3 450 3.580 3,580 Zamac Alloy Type 304 SS N/A 1,200 1,440 L840 1,980 2,740 2.230 2,550 3.145 4,015 4,020 6,400 3/4' 20 1/2 -13 3/4" 1,440 2,045 1,500 2,200 5,110 1,660 2.290 5.085 1,285 9,705 12,745 NOTE The yams fisted abole are ultimate bad capacities which should be reed by mi safely faaorof 4 or create to determine the allowable vvcrki g bad 2,240 3,280 '2,525 3,620 4,660 9,660 illlAkarEie 9Ofa trio 4BL KANDSOi D.aRICLY 1" 40 5/8 -11 1" 1.200 1,440 1,840 1,980 2,740 2,230 2,550 3,145 4,015 4,020 6.400 Or l - N a' irehTE -, r. X�e+Rll; C00 P S SfC0 - , sloq� sr tteSl:r• i_n.2 jF053 1,800 2,640 3.775 4,220 6,840 12,680 • Anchors were installed with sleeve flush to surface of the plank " Anchors were installed in sold portion of plank in anchor hol . that rid not sped into hollow cavity 1,575 1,815 2 485 3,655 3.740 1/4" 5/16" 3/8' 1/2" 5/8" 7/8" 1 -1/2" 1 -1/2" 1 -1/2" 2 -1/4" 880 1,460 1 860 3,240 4.680 1,640 2,230 2,980 4,230 6,420 *Anchors were installed with sleeve flush to face shell surface NOTE. Depending upon anchor appkadon and glomming butting code, ultimate bad capacities should be reduced by minimum safety facmrof or greater to determine the allowable working bad The design professional &Oiar with the actual product installation should be consrdted Please refer to the general section entitled Evallatbn of Test Data that appears varier in this manual for current ardaaystandards The consstency of plank C90 hollow block and sold red brick varies greatly. The bad capacities fisted above should be used as guidelines only Job site tests should be conducted to verify base material consistency, properirstaiation toque values and actual anchor performance DESIGN aCRITERIA ,' " " xsi- fireR7 @CNEScae"s2te Rr., ....... In solid base materials, the minimum recommended thickness of base material, BMT, when using the Hollow -Set Dropin is 125% of the embedment for solid materials to be used For hollow materials a minimum wall thickness of 1 -1/2" is suggested Job site tests should be performed on installations in hollow base materials 0-4 ortz 3;11 " M • ...... To obtain the maximum load in tension or shear, a spacing, S of 10 anchor diameters (10D) or greater should be used The minimum recommended anchor spacing, S. is 5 anchor ciameters (50) at which point the load should be reduced by 50 %. Anchor spacing doser or less than 5 diameters (50) needs to be field tested Actual base material conditions will determine any applicable reduction factor. The following table lists the load reduction factor, Rs, for each anchor diameter, D, based on the center to center anchor sparing ' Ae ' fi SiCR, ;fACthG�ii1fiCT�ESI �C:rra' -. 3[£y�ISIQt'yAt SSFIf}41.i1 ?fi�.�'` 1/4 2 -1/2 2 -1/4 2 1 -3/4 1 -1/2 1 -1/4 5/16 3-1/8 2 -7/8 2 -1/2 2 -1/4 1 -7/8 1 -1/2 3/8 3 -3/4 3 -3/8 3 2-5/8 2 -1/4 1.7/8 1/2 5 4 -1/2 4 3 -1/2 3 2 -1/2 5/8 6.1/4 5 -5/8 5 4 -3/8 3-3/4 3-1/8 Rs 1.00 0.90 0.80 0.70 0.60 0.50 t�.,!EOGEFDIST� Q a O » 3t� - r'3 - Malei.'K's:te:S;472nil. M For tension loads, an edge distance, E, of 12 diameters (12D) or greater should be used to obtain the maximum tension load The minimum recommended edge distance, E, is 8 diameters (80) at which point the tension load should be reduced by 20 %. Edge distances closer or less than 8 diameters (8D) need to be field tested Actual base material conditions will determine any applicable CC. Re: To: Marcelo Garces Sabey Corporation 12201 Tukwila International Blvd Fourth Floor Seattle, WA 98168 206.281.8700 From: Kevin Sahara KPFF Consulting Engineers 1601 Fifth Avenue Suite 1600 Seattle, WA 98101 206.622.5822 These are transmitted: As Submitted Remarks: IGE Chiller Wall LETTER OF TRANSMITTAL Date: Job: # Project We are sending to you the attached: See Description Below Via: Courier Same Day Copies Dated 1 2/14/08 # of Shts. 5 Description Structural Calcs for IGE 4 Screen Wall 2/29/08 107545.10 IGE Building 4 Screen Wall 6 MAC � 3 2005 Sabey Cor Sabey Corporation IGE Building 4 - Screen Wall Tukwila, WA Structural Calculations CALCULATIONS INCLUDED: Pages 1 through 5 These Calculations cover this scope: Structural design of masonry screen walls for building refrigerator units. 1601 Fifth Avenue, Suite 1600 Seattle, WA 98101 KPFF Project No. 107545.10 Date 2/29/08 kpff Consulting Engineers 1601 5th Avenue, Suite 1600 Seattle. WA 98101 (206) 622 -5822 Fax (206) 622 -8130 seismic wind assumptions Name Symbol P Equation Parameter tuna 157,5 Ifs 9.625 in 0.80208 ft Equivalent - IUnit Axial Load Wall Thickness 1 Reinforcement Spacing/ Grout Si.cin. Eccentricity e = t/2 4.8125 in 0.401042 ft Lateral Load w 95 psi Wait Height h 8 ft 96 in Horizontal Reaction @ Wall Bottom R. = P. — + wh h lb/ft 767.9 — ft Maximum Moment Location (Dist From Top of Wall) x R ' w 8.00 ft Maximum Moment M max = wh 2 — 2 Ib`fi 3040 — ft Reinforcement Spacing b 8 in 0.6666667 ft Design Maximum Moment Mma.da,g, = wax (2027 bit Masonry Compressive Strength fm 1500 psi Allowable Masonry Stress F,,, :: f 3 500 psi Steel Modulus of Elasticity E, 29000000 psi Masonry Modulus of Elasticity E == 900 ? 1350000 psi n= E, — E 21.5[1 Steel Bar(s) Used (1) /I6 0.75 in Diameter of Steel Provided d,, Area of Steel Provided A, _ Pi'd, 0.44 in — 4 Effective Depth d 4.8125 in p= A, -- bd 0.0115[) = = ((np) 2 +2np) O 5 -np k 1-- 3 0.498 1) 0.83411 Masonry Resisting Moment Per Section M'm ._ Fmkfbdz - -- 2 19228 !bin 1602 !bit Allowable Steel Stress F. 24000 psi Steel Resisting Moment Per Section M. ' F,A,Jd 42562 Ib`in 3547 bit Weight of Wall Section w„„ 116 psf Area of Wall Section A„„, 116 in Axial Compressive Stress f, = P + w,..„ - (h-x) 1.4 psi A,,, Nominal Thickness t, 10 in Allowable Compressive Stress F. = 0.2f (1- (12h/40t„)') 295.9 psi Allowable Compressive Stress With 413 Stress increase 4 F. 3 394.5 psi Governing Resisting Moment M, 1602 bit Governing Resisting Moment With 4/3 Stress Increase 4 3 M' 3 Ib 02136 I ) – - Unity Equation Using 4/3 Stress Increase With Wind or Seismic Loads f, M„w . + < 1.0 0.952 [ ) F, M, "a ummary Nominal Wall Thickness 10 in Actual Wall Thickness 9.625 in Relnforcin, Bars (1) #6 Reinforcement Spacing/ Grout Si.cin. 8 ino.c. t - Nl CO 1>siC r�� Consulting Engineers 1601 Filth Ave. Suite 1600 Seattle, WA 98101 (206) 622 -5822 Fax (206) 622 -8130 project \ (--,I - 4 Sc .K1 W ALL. location Glen Lam` \ =R ` T C.uLt kJ ALL by • date sheet no. lob no. L� \ Al \ e ) t)l y,:.[lY '! °t_ , •••' �� 4t Ir4J 1 . 1/21" 'n` 1-ov c i 1 e t: J 4 � Lc c�C�t*1 1 cal uN +r Cm .a..t t y i \ -� J �lvr c_0` 1 k I t's le■ 0rJ 4�J� {tit 4 = SCE 1� SO4 1 by vtJu 575 110 2 veins rd = 1 00'6' oCo.y 0.9 x !t�._`1 C, - ` 2G.Ca I �� 1 �, VL. = A = boo ti: k U -Cb7S 39t5-7s U. -S -;' *-10 > V, ✓ s ,ca• Capacd J -cov \A oil t_,> 1 dvoiNN1 Per edc�¢v L� 3 x % coNiinkt wS:? — ( 15.Z x � X (3 1,J > Z S o>��Ip I bvt (2 - 75 1,,1(b.2S t�,�� = G . O2 tu { 71 , E - CI) ' 1-1 x - lb T.3 = I(3 2 (0 > M ✓ 1 5 " 12 - Iti = 2 Consulting Engineers 1601 5th Avenue. Suite 1600 Seattle. WA 98101 (206) 622.5822 Fax (206) 622 -8130 t -•l Ct t , r Z I r a L` Foz C " t L .. T -1 T CL k Cc. tQr 0 41 _0„ -1LT1 I +r 11` - tso_ DIiEVVE. pro /6E Sc2&, ALL location client DEVAIL A = Ct`-kl C -)tiul -tkiS %0" tai c -i<i q(iL. t - rYP Stet s Ex F F1 by K - r - s date 2 /29 7 0 8 sheet no. job no. ?JEW CMu RALLY' Clean U. a Ct RALLY E CU T� •( 'w 7gOi.ATE D 5\AO A L 11.1 PE C T t(4 SCME PULE Esitusom -1E0 PE 2w6 MC, SECTICilIQ %O9 • Q.01 TZ r- ( M.1\1 CoAl-t'1t4UOUS 1N5.3,tT1 C Rto41c 1tssPGCT► cc.) n.l me- t.1 Ts Co>v crzE TC Qc1)-ge ce 1"i. Pl aca., e.+o+ X TRv=_IA,tF -AL M ASON2 , ( )( x 1 y/ k \Net - 11( 1V t o• SFrAo S }h rel j k 4c' cz6 P a SQ1 rXt: ;i be. Twv #lns Level vpircic 1 11. spec +lolss rec .4,e,..,1-s ,,.. 1C Talk., esse ?-\ cx.1 { 1, l (occc., cG 'e-S 1,11 Consulting Engineers 1601 51h Avenue. Suite 1600 Seattle, WA 98101 (206) 622 -5822 Fax (206) 622 -8130 C ';r.S/3lacz' All ( o-JC 4e catoury U1Jlh sha U�� ► ��t -Lr ASCM C'c{ lvt \\ n ct -tc'v r c tit C P c Ut.n,'>rw %N.). ( 1S()0 s\,...0 t ■ c M1- t5 *�1ihn\ M cc�� tSANIe ( �� ►.,q n c)t � . Sc.)G lc"si CUNC -e ti1QSulvvtt �JGS wkA{1 lae. vN,1.1FV.,LI J e- c1 Ya T i L'QTncz A 1 t ' "41Q�'- s`p-e c cl LVJtC{. ".4v { ' tiVs } kcI I�ctuvf c vN�u�tur u� VC 11 c c.} ■✓0, S 1,&).}1s ' \G11 ! YOUTCCl • project C. \),311k1 location client Dc }S x:L " 1. NI ASON1 -e r ktkS' 1•1u \-ec1 o sty c (\ loo►.,d 1 0,,.. Nit c2JA. -1(.3TE S by t�) date /2 : U � S 4si s1.011 -}„ 1SC. S.<- zIt.)3 shall c A-0 gC `": =41U■4 2.1U3.l Z . C �vo� S \ _ U 6C Tc.,1 21()3 lZ , 1 4v.„ So r.1 S‘kal he - \tz.cl w 1 }j.� � ,,,. i- • .11 A, 00-c &s n10 c1 c�+L�evtMl s sheet no. tab no �ke \3Q"C' ltiS S\ a{ °NCtiv IBC Se, 1-, U „_, -? 103.13 (c"(D UtJ }`.:•1` 17Q sx- 0.) VE' }v (mil GQC, SIBEY • COR PORATION March 17, 2008 Allen Johannessen City of Tukwila 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Dear Mr Johannessen, I am writing to clarify our submittal for the Development Application Number D08 -045 so we can obtain our permit and move forward with this work. The plan for the chiller wall shows a screen in- between the CMU columns. This screen will be the Ruskin louver that you received a specifications sheet for. The louvers will also be used for the gate which will be fastened in a similar fashion. The typical Masonry Wall detail shown will be used to secure the louvers to the columns. The louvers will be fastened with a wedge type concrete anchor equal to the submitted anchor or better. I also included engineering calculations for the columns to support the louvers from our structural engineer. I believe this should clarify your two review comments and confirm our conversation last Friday requesting this clarification. Sincerely, SABEY CONSTRUCTION Josh Johnon Project Engineer REAL ESTATE DEVELOPMENT SabeyCorporation CONSTRUCTION / ARCHITECTURE / 12201 Tukwila International Blvd., 4th Floor INVESTMENTS / Seattle, Washington 98168 -5121 / CORRECTION LTR #__L OO8 O'iS 206/281 8700 main line 206 /282 -9951 fax line www.sabey.com LIAR 17 2008 PEhivllI UENTEE, 0 ni in:rvf on thlorire free, ' Olr. posh rers.erer waste tiller paper i March 10, 2008 David D. Kanh 12201 Tukwila International BI 4 Floor Seattle, WA 98168 RE: CORRECTION LETTER #2 Development Application Number D08 -045 Intergate East 4 — 3433 South 120 Place Dear Mr. Kanh, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen, at 206 - 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Siyicerely, Brenda Holt Permit Coordinator encl • Cizy of Tukwila xc: File No. D08 -045 Department of Community Development Jack Pace, Director P:\Permit Cen ter \Correction Letters\2008\D08 -045 Correction Ltr 42.DOC wer • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: March 10, 2008 Project Name: Intergate 4 Chiller Wall Permit #: D08 -045 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Previous letter item 2) requested hardware specifications for the infill panels. However information provided was manufacture specifications for stationary louvers. Please provide information as requested (see item #2 below). 2. Provide details that specify hardware connecting the infill panels and gate assembly to the masonry piers. Include manufactures specifications for the infill panels. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. February 8, 2008 David D. Kanh 12201 Tukwila International B1 4 Floor Seattle, WA 98168 RE: CORRECTION LETTER #1 Development Application Number D08 -045 Intergate East 4 — 3433 South 120 Place Dear Mr. Kanh, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen, at 206 -433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Brenda Holt Permit Coordinator encl • City of Tukwila Department of Community Development Jack Pace, Director kt)-- xc: File No. D08 -045 P:\Permit Center\Correction Letters\2008\D08 -045 Correction Ltr #1.DOC wer • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Budding Division Review Memo • • Date: February 06, 2008 Project Name: Intergate 4 Chiller Wall Permit #: D08 -045 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide an engineer's seismic and wind analysis for the chiller wall. Analysis shall specify grout and mortar requirements. Engineering shall provide special inspection requirements. (IBC 1704.5, 2101.2 & 2101.3) 2. Provide details that specify hardware connecting the infill panels and gate assembly to the masonry piers. Include manufactures specifications for the infill panels. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D08 -045 DATE: 03 -18 -08 PROJECT NAME: INTERGATE EAST 4 SITE ADDRESS: 3433 S 120 PI Original Plan Submittal X Response to Correction Letter # 2 Revision # After Permit Issued DEPARTMENTS: di t t iO 5 B Ing'Lyivision Public Works ❑ TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Planning Division Structural Response to Incomplete Letter # DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03-20-08 Complete Q Incomplete 1 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DATE: Permit Coordinator DUE DATE: 04 -17 -08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -045 DATE: 03 -05 -08 PROJECT NAME: INTERGATE EAST 4 SITE ADDRESS: 3433 S 120 PL Original Plan Submittal X Response to Correction Letter # 1 Revision # After Permit Issued Response to Incomplete Letter # D / P/ RTMENT� 0-46 � •n B id gD Public Works PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Fire Prevention Structural Complete Q Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing siip.doc 2 -28 -02 n Planning Division Permit Center Use Only CORRECTION LETTER MAILED: " V' Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Permit Coordinator DUE DATE: 03 -06-08 LETTER OF COMPLETENESS MAILED: No further Review Required DUE DATE: 04 -03-08 Not Approved (attach comments) DATE: '� ACTIVITY NUMBER: D08 -045 DATE: 01 -29 -08 PROJECT NAME: INTERGATE 4 CHILLER WALL SITE ADDRESS: 3433 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: BuiI•i� Div Public. Works Complete Comments: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 4 ERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES/THURS R TING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 6Id 114, 1-1°-° Fire revention Structural Incomplete n DATE: Planning Division Permit Coordinator DUE DATE: 01 -31 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n No further Review Required n DUE DATE: 02 -28 -08 Notation: DATE: Permit Center Use Only /� Q CORRECTION LETTER MAILED: `/ U �Q Departments issued corrections: Bldg IV Fire ❑ Ping ❑ PW ❑ Staff Initials: Approved 1 Approved with Conditions n Not Approved (attach comments) Ff • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1 REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 3 1 7 -- 0 j Plan Check/Permit Number: D08 -045 ❑ Response to Incomplete Letter # Response to Correction Letter # 2 ❑ Revision # ^ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: INTERGATE EAST 4 Project Address: 3433 South 120 Place Contact Person: David Kang Summary of Revision: SE ATt Sheet Number(s): "Cloud" or highlight all areas of revision including date of rev is Received at the City of Tukwila Permit Center by: LET in Permits Plus on Z,_ t -d j \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Phone Number:( & )Z? SL"Y 3 Tea yr t aw63 RECEIVED QTY C' TUKWIL A ■1Ai. 17 L00u PERMIT CENTER Contact Person: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa. us REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Z / '7 d r Plan Check/Permit Number: D08 -045 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # — after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: INTERGATE EAST 4 Project Address: 3433 S 120 P1 David Kant Phone Number:(?'4) L7 -Y Summary of Revision: SL.) i rN S s 5 id P tA3 0-ee r I S Se._; I i L a w i l� C �- 'FLU.- t.„-)40-1 a�.4- J A L ( 'CI h Corm ion ke v� v► ur l , 5 v 0 -C ot.c6cg !V 0 1-. L. +; tit^i0-e-t (0 A-P (-A KNA foo 44_ 1141/ totite 1f emit ar h c 0 . Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \ applications \torms - applications on line \revision submittal Created: 8 -13 -2004 Revised: RECEIVED CITY 4V TUKWIL4 MAR, 05 ZUUU EIS License Information License SABEYC *953RE Licensee Name SABEY CORPORATION Licensee Type CONSTRUCTION CONTRACTOR UBI 600254734 Ind. Ins. Account Id 33122101 Business Type CORPORATION Address 1 12201 TUKWILA INTL BLVD 4THFL Address 2 City SEATTLE County KING State WA Zip 981685121 Phone 2062818700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/5/2005 Expiration Date 12/5/2009 Suspend Date Separation Date Parent Company Previous License SABEYCI033 Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 HARTFORD FIRE INS CO 52BSBDQ2825 11/29/2005 Until Cancelled $12,000.00 12/05/2005 Business Owner Information Name Role Effective Date Expiration Date SABEY, DAVID A PRESIDENT 12/05/2005 HARMON, JAMES N SECRETARY 12/05/2005 Look Up a Contractor, Electrician or Plumber License Detail • Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SABEYC *953RE 03/24/2008 Plan S STRUCTURAL GRID ROOM REFERENCE DOoR REFERENCE DOOR LOCATION DOOR ACTION RELITE WITH SILL FULL HEIGHT RELITE KEY NOTES PARTITION TYPE DETAIL REFERENCE WALL SECTION BUILDING SECTION REFERENCE OR DATUM FIRE EXTINGUISHER ELEVATION REFERENCE ALIGN FACE OF FINISH WITH FACE OF FINISH CATCH BASIN FLOOR DRAIN REVISION REFERENCE mbols 0 0 104 Abbreviations AC ACT ADJ AFT ALT ALUM IE ANOD APPROX ARCH BLDG BLK'G BM 13/5 BSMT CAS CIRG CLR CLG CLOS CCP COL CONC CONST CONT CONTR COORD CPT CT PET DIA D IAG DIM DN DR DWG Air Conditioning Acoustical Ceiling Tile Adjustable /Adjacent Acoustical Floor Tile Alternate Aluminum Angle Anodized Approxima tely Architectural At Bui ldine Blocking Seam Building Standard Basement Cabinet Circulation Clear or Clearance Ceiling Center Line Closet Contract Change Proposal Column Concrete Construction Continuous Contractor Coordinate Carpet Ceramic Tile Deta Diameter Diagonal Dimension Down Door Drawing OFFICE = ROOM NAME ROOM NUMBER I' -6' CLEAR PER ADA REQUIREMENTS FOR FRONT AF'F°ROACN FRENCH DOORS NIL - DOOR NUMBER E EA EL ELEC ELEV EQ EQUIP EXIST FE FEC FIN FLR FLUOR FOIC FT FTiC FURN GA GALV GL GWB HCW HD HDW HOR HM HT HYAC IN INCAN INCL INSUL iNSTL JB JT 4 " TYP. REFER 70 DETAIL 22/A102 Poor Number INDICATES ACTIVE LEAF SEE LEGEND DETAIL NUMBER/LETTER DRAWING NUMBER SECTION NUMBER DRAWING NUMBER SECTION LETTER DRAWING NUMBER REVISION NUMBER ONLY MOST RECENT REVISION 15 CLOUDED Inch Incandescent Include Insulation Installation Junction Box Joint SEMI - RECESSED FIRE EXTINGUISHER CABINET U.N.O. REFER TO DETAIL 6/A10.2 ( INDICATES A FULLY RECESSED FIRE �EC FE EXTINGUISHER CABINET SURFACE MOUNTED FIRE EXTINGUISHER SUPPLIED B7 OWNER ELEVATION REFERENCE DRAWING NUMBEFR East Each Elevation (Height) Electric Elevation (View) Elevator Equal Equipment Existing Fire Extinguisher Fire Extinguisher Cabinet Finish Floor Fluorescent Furnished by Owner, Installed by Contractor Foot/Feet Furnished by Tenant, Installed by Contractor Furnish Furnishings Gauge Galvanized Glass /Gla Gypsum Wall Board Hollow Core Wood Hard Hardware Horizontal Hollow Metal Height Heating Ventilation and Air Conditioning KIT LAM LF LTG MAT MAX MECH MED MEZZ MFR MISC MTD MTL Kitchen Laminate Lineal Feet Lighting Material Maximum Mechanical Medium Mezzanine Manufacturer Miscellaneous Mounted Material/Metal N North N/A Not Applicable NIC Nat in Contract NO Number NOM Nominal NON COMB Non Combustible NTS Not to Scale OC OPNG OPP ORIG PERM PERP f1? P -LAM PLWD POL PR PT Vicinity Map On Center Opening Opposite. OrieInal Permanent Perpendicular Plate Plastic Laminate Plywood Polished Pair Paint RB REFR RE INF REQ'D REV R1 RO 5 SCHED SCIU SEAL SECT SHT SIM SM 50 STD STL SIG SUSP TEL TEMP THERMO TO TYP UNO VAR VCT YEN VERT W W/ W/O WC WD Radius Rubber Base Refrigerator Rein forcing Required Rev( Ion Room Rough Opening South Schedule Solid Core Wood Sealant Section Sheet Similar Sheet Metal Square Standard Steel Storage Suspended Telephone Tempered Thermostat Top OF Typical Unless Noted Otherwise Varies Vinyl Composition Tile Veneer Vertical West/Watt/Width With Without Wa l lcoverine Wood Location Plan , ! ur r ie a !I!'' a ' General Notes CODES A. All work shall conform to the applicable building codes and ordinances. In case oF any conflict where the methods or standards of installation or the materials specified do riot equal or exceed the requirements of the laws or ordinances, the laws or ordinances shall govern. Notify the Architect of all Conflicts. Ti-1 pR4W1NGS AND SPECIFICATIONS A. Structural, plumbing, mechanical, electrical and fire protection drawings are supplementary to these drawings. The Contractor s hall coordinate the work of each consulting engineer with these drawings and the Tenant Improvement Specifications and shall notify the Architect of all discrepancies with a written request for clarification: Any work installed in conflict with the drawings or the Tenant Improvement Specifications shall be corrected by the Contractor at no th expense to the Owner, Tenant or e Architect. B. (defer to Sheet 402 AND 40.3 for additional notes and specifications C. ReFer to demolition drawings and specifications, for additional information. it will be Contractors' responsibility to coordinate any /all work between drawing packages. DIMENSIONS A. All information shown on the drawings relative to existing conditions is given as the best present knowledge but without guarantee of accuracy. The Contractor shall Field verify existing conditions a ffecting the design prior to proceeding with the item of work affected. B. Dimensions on the plans are typically to the Finish face of partitions, Face oF CMU, or to the center line of columns. G. Door and cased openings without location dimensions are to be four and one -half (4 I/2') inches From the faces oF adjacent partition or centered between partitions. D. Locate partitions that are not dimensioned Flush and square with the existing structure or on the centerline or a window mullion as shown. DO NOT SCALE DRAWINGS A. The Contractor s hall use dimensions shown on the drawings and actual Field measurements. Notify the Architect of any discrepancies Found. AeeREviATIONS A. Throughout the drawings are abbreviations which are in common use. The list of abbreviations provided is not intended to be complete or representative of' conditions or materials actually used on the project. The Architect will define the intent of any in question. COORDINATION A. The General Contractor 4 Tenant shall be responsible for the coordination and verification of the work of all trades to assure compliance with the drawings and specifications. Description of Work REBUILD PcTERIOR CHILLER WALL. Project Team LANDLORD'S REPRESENTATIVE: SABEY CORPORATION 12201 TUKWILA INTERNATIONAL BLVD 4T14 FLOOR SEATTLE WA 98168 -8121 TEL : (206) 28I -8100 FAX : (206) 281 -0920 CONTACT : MARCELO GARCE6 E-MAIL S mareslegesabey.com ARCHITECT OF RECORD: SABEY ARCHITECTURE 12201 TUKWILA INTERNATIONAL BLVD 4TW FLOOR SEATTLE WA 98168 -5121 TEL : (206) 281 -8100 FAX : (206) 281 -0520 CONTACT : SANDRA SUSKIC E -MAIL eandr•asesabey:com GENERAL CONTRACTOR: SABEY CONSTRUCTION, INC. 12201 TUKWILA INTERNATIONAL BLVD 4TH FLOOR SEATTLE WA 98168 -5121 TEL : (206) 281 - 8100 FAX : (206) 281 -0920 CONTACT : MARCELO GARCES MOBILE : (206) 321 -4ITI E -MAIL: marcelosesabey.com Project Project Name CHILLER WALL AT IN7E1%ATE EAST 3433 SOUTH 120TH PLACE TUKWILA, WA 98168 Data Zoning MiC/14 MANUFACTURING INDUSTRIAL CENTER /HEAVY Site Area 113,985 SF Seismic Zone 3 Design Codes IBC 2006 Legal Description LOT 2 OF SHORT PLAT No. -Issas, ACCORDING TO THE SHORT PLAT RECORDED UNDER KING COUNTY RECORDING NO. 86032409301 TOGETHER WITH THAT PORTION OF THE NORTH HALF OF VACATED SOUTH 124TH STREET LYING EAST OF THE SOUTHERLY PRODUCTION OF THE WEST LINE OF SAID LOT 2 OF THE SHORT PLAT AND WESTERLY OF A LINE BEING 30 FEET WEST OF AND PARALLEL WITH THE NORTHERLY EXTENSION OF THE CENTERLINE OF 35TH AVENUE SOUTH AS LOCATED BY THE PLAT OF RIVERTON± AND TOGETHER WITH THAT PORTION OF VACATED 35TH AVENUE SOUTH ADJOINING, A5 VACATED UNDER CITY OF TUKWILA ORDINANCE NO. 1512, RECORDED UNDER RECORDING NO. 9009111032 WHICH, UPON VACATION , ATTACHES TO SAID PROPERTY BY OPERATION OF LAWi SITUATE N THE CITY OF TUKWILA, COJTN OF KING, STATE OF WASHINGTON. Drawing Index ARCHITECTURAL: A 0.0 PROJECT COVER MEET .4 1.0 SITE VIEW. DEMO PLAN. SECTION VIEW. DETAILS. FIRE PROTECTION A. iF necessary, provide fire stopping at all vertical and horizontal penetrations of Fire rated elements as required by the governing authority. (3. Contractor is responsible For modifications to the existing Fire Protection Systems as required by the work of this Contract. C. Contractor s hall provide occupancy signs conforming with applicable code requirements. D. Contractor shall provide exit signs in the type, number and location as shown on plans, or a s otherwise required by the local inspector. E. All exit doors shall be openable From the inside without key or any special knowledge. F. interior Finishes shall not exceed a Flame spread rating of 25 at exit corridors (walls 4 ceilings per UBC Chapter S), G. All modifications and /or expansion of the building fire alarm system are to comply with the Washington State Building Code ADA 4 Washington State barrier Free requirements For visual and audible alarm signals. H. Refer to Sheet A 0.2 For additional Fire Protection notes. GENERAL CONSTRUCTION A. The contractor shall investigate and verify locations of structural, mechanical and electrical elements and other existing conditions prior to drilling or cutting of slabs or structural members. Notify the Architect of any conflicts prior to beginning work B. The Contractor shall be responsible for providing all wall blocking as required For all wall and ceiling mounted items. C. All construction shall be s tabilized against lateral movement in accordance with the requirements of the latest adopted edition of the UBC in the local jurisdiction. D. Ceiling heights, where indicated, are From sub floor to bottom of ceiling grid or other Finished surface. E. Mechanical, electrical and sprinkler work s hall be conducted under separate permits. GENERAL FH A. Ther e shall be NOTES no exposed pipe, conduit, duct, vents, etc. All such lines shall be concealed or Furred and Ffnfehed, unless noted as exposed construction on drawings. • OFFeet studs where required so that finish wall surfaces will be Flush. C. Provide galvanic insulation between dissimilar metals. ReFer to Sheet A 92 For additional Finish notes WALL FINISH NOTES A. All paint, wallcoverings and wall panels shall be applied in accordance with the manufacturer's specifications For the particular surface applied upon. B. Samples of all Finish colors specified shall be submitted for approval by Architect prior to the commencement of work C. Flame s pread ratings For interior finish to be Glass 3 or better. D. Paint 1 is the general paint color unless otherwise noted. SEPARATE PERMIT REQUIRED t M echanical EIeCtn [ Plumbing Gas Piping City p� BUILDING DIVISION Building Data Address 9433 SOUTH 120TH PLACE TUKWILA, WA 98168 Building Owner INTERNATIONAL GATEWAY EAST, LLC 12201 TUKWILA INTERNATIONAL BLVD FOURTH FLOOR SEATTLE, WASHINGTON 9$I6S -5I2I TEL: (206)281-S100 CONTACT: CHRISTINA HOLD Tax Parcel Number 102304 - 9081 -00 Construction Type V - 1 HR FULLY SPRINCLEREDi I - STORY - UBC J V -A WITH AUTOMATIC SPRINKLER SYSTEM - IBC ReVIEWED OR 2 0 0� Building Area Occupancy Parking NO CHANGES Loading Dock NO CHANGES REVISIONS No changes shalt be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional olan review fees • ELECTRICAL /TELEPHONE NOTES UNDER S PERMIT MECHANICAL NOTES UNDER SEPARATE PERMIT FILE COPY Ponsilt Mart Wow approval le ettlivitto anion and omissions. Approval of conebuction documents does not authorize the violation cloy adopted code or odium Receipt of approved Reid Copland condNionele acknowledged: Debt, 3 / f/? TOTAL FLOOR 116,019 SF NORTH CHILLER YARD: 615e SF SOUTH SERVICE YARD: 9,535 5F Fl - ELECTRONIC SWITCH GEAR FACILITY 101,933 SF A3 - BREAK RI/LOUNGE 1,054 SF 143 - RPU ENCLOSURES 6,313 SF City ofTukwila BUILDING DIVISION PERMIT CENiTEF OO8 Oi5 JAN 2 9 2008 APPROVED BY: ARCHITECTURE REGISTERED Hi E KARA M. ANDERSON STATE OF WASHINGTON CONSULTANTS REVISIONS 6194 ISSUE DATE All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same ma not be duplicated, used or disclosed without the written consent of the Sabey Corporation. CHILLER WALL INTERGATE EAST BUILDING 4 PLOT: PROJECT NUMBER: DRAWN BY: -D CHECKED BY: intergat 3433 South 124th. Place Tukwila, WA DRAWING TITLE: PROGRESS DATE: FILE: DRAWING NUMBER: 01 - 23 -2008 PROJECT COVER SHEET SITE VIEW SCALE: I/8' • 1' -0" 411 KEY NOTES: 1. EXISTING CONCRETE FOOTINGS 2. CMU COLUMNS 3. INFILL PANELS - GRILLS BY ORSO GRIL OWNER TO SELECT FROM STANDARD COLORS 4. GATE 6'x1O' PROVIDE STUB FOR KEY CARD SYSTEM BY ORS° GRIL FULLY GROUTED EXISTING CMU WALL DEMO PL4N SCALE: 1A6" • 1I -0" TYP. ELEVATION VIEW SCALES 1/$l • •11 -011 :10,. 2!222 Ii3ei� = i ?silsl : :Il PAINT EXISTING CMU :..2...:21:2:..:...1 IS NZ :!!!!!Ilan FULLY GROUTED EXISTING CMU WALL GRILL 13Y ORSO GRIL CONNECT TO PIERS PER MANUFACTURE RECOMMENDED DETAILS . 211112111 alb 2.22221:11 a: : :: :2111111111 PAINT EXISTING CMU ELEVATION VIEW SCALE: VS" • 1' -0' d x 0 10' CUM WALL CMU - TYPE 1 SPLIT PACE (2) #4 CONT. HORIZON REINFORCEMENT DONE SEAM 4 -O ", 8' -O ", & 1O' -O" ELEVATION #6 016" O.C. OR (1) #6 BAR PER 16" COL VERTICAL REINFORCEMENT NEW CMU FULLY GROUT ALL CELLS EX CMU TO REMAIN ASSUMED FULLY GROUTED HILT! HIT HY -ISO ADHESIVE SECTION T -IIRu CMU WALL SCALE: 3/4" • 1' -0" NOTE:GAP- NOT TO EXCEED 4" EXISTING CMU LUALL DETAIL OF GRILL F'ANE:L SCALE: 3/4" • 1I -fu il• 111111111111 i EXISTING SLAB EXISTING STIRRUPS & CAP TIES ' T ALT. 90 DEGREE HOOK DOS -ors REVIEWED FOR CODE COMPLIANCE APPROVED "BAR 2 n 2000 City Of Tukwila I I a:G DIVISION CMU - TYPE 2 SMOOTN JAN 2 9 200$ P. S BEY CONSULTANTS REVISIONS DRAWING TITLE: PROGRESS DATE: FILE: PLOT: ARCHITECTURE ISSUE DATE All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sobey Corporation. CHILLER WALL @ INTERGATE EAST BUILDING 4 nterd a 'CAMPUS 3433 South 120th. Race Tukwila, WA PROJECT NUMBER: DRAWN BY: CHECKED BY: APPROVED BY: DRAWING NUMBER: Al REGISTERED AA-ay T ,41 KARA M. ANDERSON STATE OF WASHINGTON SITE YIELD DEMO FLAN SECTION YIELD 01 -23- 2008 DETAILS