Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-050 - WESTFIELD SOUTHCENTER MALL - AERIE - TENANT IMPROVEMENT
AERIE 2656 SOTJTHCENTER MALL D08 -050 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. / /www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D08 -050 Occupant /Tenant: AERIE Building Address: 2656 SOUTHCENTER MALL, SUITE NO. Parcel No.: 6364200010 Property Owner: WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA 90025 Use: RETAIL Occupancy Group /Division: M Type of Construction: II -B Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: 118 THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: 6364200010 Address: 2656 SOUTHCENTER MALL TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: AERIE Address: 2656 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA 90025 Phone: Contact Person: Name: SCOTT DAVES Address: 140 S LAKE AV, STE 323 , PASADENA CA 91101 Phone: 626 585 -2931 Contractor: Name: NATIONAL BUILDING CONTRACTORS Address: 1650 CARROLL AVE , SAINT PAUL MN 55104 Phone: 651- 222 -1859 Contractor License No: NATIOBC962RG DESCRIPTION OF WORK: NEW TENANT IMPROVEMENT doc: IBC -10/06 CitAtf Tukwila • DEVELOPMENT PERMIT Value of Construction: $256,000.00 Fees Collected: $3,953.28 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: IIB Occupancy per IBC: 0019 * *continued on next page ** Permit Number: D08 - 050 Issue Date: 04/14/2008 Permit Expires On: 10/11/2008 Expiration Date: 12/07/2008 D08 -050 Printed: 04 -14 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City &Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: governing this work will be complied , whether specified herein or not. Permit Number: DO8 - 050 Issue Date: 04/14/2008 Permit Expires On: 10/11/2008 Date: CLj I'1 I hereby certify that I have read and -'"y ' ed this permit and know the same to be true and correct. All provisions of law and ordinances The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructi•n or the performance of wo I am authorized to sign and obtain this development permit. Signature: - Date: y ` t y - o c& Print Name Io^MPS 3'n-1 LP This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10106 D08 -050 Printed: 04 -14 -2008 • City of Tukwila Parcel No.: 6364200010 Address: 2656 SOUTHCENTER MALL TUKW Suite No: Tenant: AERIE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us PERMIT CONDITIONS • Permit Number: D08 -050 Status: ISSUED Applied Date: 02/04/2008 Issue Date: 04/14/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) doc: Cond -10/06 D08 -050 Printed: 04 -14 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IF'C 1011.1) 24: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 nun) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the doc: Cond -10/06 D08 -050 Printed: 04 -14 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 32: Local U.L. central station supervision is required. (City Ordinance #2051) 33: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 36: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 37: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 38: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 39: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 40: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 41: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 42: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at doc: Cond -10/06 D08 -050 Printed: 04 -14 -2008 (206)575 -4407. doc: Cond -10/06 ! • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us * * continued on next page ** D08 -050 Printed: 04 -14 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. L i — Signature: Date: ( 0 Print Name: � A'srYve S N "K doc: Cond -10/06 D08 -050 ordinances governing or local laws regulating Printed: 04 -14 -2008 44 Name: a LU 15 / Delay f L1 c • " Sca &baVes Mailing Address: / f kit kt— Avg 1444 & - .3 E -Mail Address: ?e " ingA / el 61 do/ earn Company Name: /l/'- /f1 L Mailing Address: SZ (l- Contact Person: • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us 611 I en/ a QAApplications'Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh E -Mail Address: mic Jibe-06451Y LAC 1 Y1 • U_ s Contractor Registration Number: Company Name: P1Z 11 n e rk1 Mailing Address: / /L/ Sl2V btu th 4 Contact Person: l e i 60 ;6 JG m t s E -Mail Address: kha; € aetel ,)ht4• r7t-t- Company Name: iQ4 f-C ✓ -to G YG Al • / )) 1lYn1G 1-/ ;16 Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Building Permit No. 1701 Mechanical Permit No. an -OZc Plumbing /Gas Permit No. 170 021 Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION L.0+1 King Co Assessor's Tax No.: Site Address: we e_ � jt.(.. vi ceoiev Mai ,, a&5 . fVte.thC/Y. NO // Suite Number: 41 .10 Floor: Tenant Name: 4e ✓ /t- fit? �" New Tenant: Yes ❑..No l,( Property Owners Name: ig tit /el &'Ypey li him Mailing Address: /l11.7O1 4J1 IYni . 13 1 ✓t• CA State 11p-OO(0 /0020 Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Day Telephone: 64 / 54' 5- aty 3/ Pa se<tii teg 9/161 City State Zip Fax Number: /Qal41 7g4- 5 77 7 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) City State Zip Day Telephone: 15/ / _' / 8 5 Fax Number: /p S/ / S/ 7 G L13 3 Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record atu ea t1 t < 6.7 City State Zip Day Telephone: 43 61 111 • 702-- Fax Number: b/ 949• 4' 5.-/ ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record State Zip Page 1 of 6 4 • BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ to 54, )O Existing Building Valuation: $ �/ Scope of Work (please provide detailed information): /s? 7 Y/ r1/ (l /1-f ✓Ari rK- 7`� / S>-1 AS -�GLUN 13 3 k. e e � M etzte a(c fl-W y'x a eJ e c t r )0 /W( I,. . `� yk- - Will there be new rack storage? I Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes [V No If "yes ", explain: FIRE PROTECT1ON /HAZARDOUS MATERIALS: V Sprinklers ❑ Automatic Fire Alarm Q None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes cet. No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. QAApplications\Forms- Applications On Line' -2006 - Permit App icatton doc Revised: 9 -2006 bh Pagc 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor ? e S n � 4 2nd Floor 3 `r Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck 4 • BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ to 54, )O Existing Building Valuation: $ �/ Scope of Work (please provide detailed information): /s? 7 Y/ r1/ (l /1-f ✓Ari rK- 7`� / S>-1 AS -�GLUN 13 3 k. e e � M etzte a(c fl-W y'x a eJ e c t r )0 /W( I,. . `� yk- - Will there be new rack storage? I Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes [V No If "yes ", explain: FIRE PROTECT1ON /HAZARDOUS MATERIALS: V Sprinklers ❑ Automatic Fire Alarm Q None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes cet. No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. QAApplications\Forms- Applications On Line' -2006 - Permit App icatton doc Revised: 9 -2006 bh Pagc 2 of 6 PUBLIC WORKS PERMIT INFORMATION — 206 - 433 -0179 Scope of Work (please provide detailed information): Water District ® ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District t - ..Tukwila ❑ ...Sewer Use Certificate ❑ ...Total Cut ❑ ...Total Fill ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ ...ValVue ... Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County I lealth Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way cubic yards cubic yards ❑ ...Sanitar Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water " FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip QAApplications\Forms- Applications On Line\3 -2006 - Permit Applicanon.doc Revised: 9 -2006 bh Call before you Dig: 1- 800 - 424 -5555 ❑ .. Highline ❑ .. Renton ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Renton ❑ .. Seattle ❑ .. Right -of -way Use - Profit for Tess than 72 hours ❑ .. Right -of -way Use — Potential Disturbance WO WO # WO # ❑...Deduct Water Meter Size Private Private ❑...Traffic Impact Analysis ❑...Hold Harmless — (SAO) ❑ ...I cold Harmless — (ROW) Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace >IOOK BTU Evaporator Cooler Diffuser 13 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct / Thermostat / 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System 1 Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ Z ° - -° Scope of Work (please provide detailed information): S)wllae•U" e� V . 4r0.1 VA V bok o..J c.v4 ro� ec;t. cf, �:bw�:d•• 5s���n �ovii e VAC Spr,nk(, J I 5 f c Iw es‹ 4� .s. an Vre kJ SMo��c cl,A0 4 :„ den :c �yuttW/l by L — Bikal',1 61 l ow l � � c r t,3es Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric kl Gas _1=1 Other: Indicate type of mechanical work being installed and the quantity below: QAApplicationsWomts- Applications On Line \3-2006 - Permit App:ication.doc Rcviscd: 9 -2006 bh Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) 1 Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 1 Sinks 1 Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory I Water Closet I Building sewer or trailer park sewer Rain water system per drain (inside building) Watcr heater and/or vent I Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment I Repair or alteration of drainage or vent piping 1 Medical gas piping system serving one to five inlets /outlets for specific gas of PLUMBING AND GAS PIPING PERMIT INFORMATION - 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City Stale Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 'R � DUO Valuation of Gas Piping work (contractor's bid price): $ r r Scope of Work (please provide detailed information): lAs�a(1a�: r.., rsc e (vim p / p1 knL, 575 "M Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: m411 Sewer: /rlu,( 1f43 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:\Applicatinns\fnnns- Applications On Line r -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TIIE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING R AUTHORIZED AGENT: Signature: � i�_ Date: I'd5( 07 Print Name: I. 127,P t A• 44,0._ ,t t Day Telephone: 1 ' 7 74 5a Mailing Address: IT Ma 4 a i Yiatdcl -U. 0 t - P,- / �• W City State Zip Date Application Accepted: Q:\Applications\Fonns- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Date Application Expires: o1la-1l3 Staff Initials: Page 6 of 6 RECEIPT NO: R08 -01171 Initials: JEM Payment Date: 04/14/2008 User ID: 1165 Total Payment: 3,594.88 Payee: NATIONAL BUILDING CONTRACTORS SET ID: 0325 SET NAME: AERIE SET TRANSACTIONS: Set Member Amount D08 -069 EL08 -107 M08 -025 PG08 -028 TOTAL: TRANSACTION LIST: Type Method Description Payment Check 36981 3,594.88 TOTAL: 3,594.88 ACCOUNT ITEM LIST: Description 2,397.50 111.00 541.20 369.18 176.00 2,397.50 BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE SET RECEIPT Amount Account Code Current Pmts 000/322.100 2,499.50 000.322.101.00.0 541.20 000/322.100 369.18 000.322.103.00.0 176.00 000/386.904 9.00 TOTAL: 3,594.88 nnr.• arrccmesa RECEIPT NO: R08 -00314 Initials: JEM User ID: 1165 Payee: PERMITS TODAY LLC SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http. //wwv. ci. tukwila. wa. us D08 -050 1,555.78 D08 -069 69.23 EL08 -107 135.30 M08 -025 84.80 PGO8 -028 35.00 TOTAL: 1,880.11 SET RECEIPT SET ID: 0204 SET NAME: AERIE TRANSACTION LIST: Type Method Description Amount Payment Check 1811 TOTAL: Account Code Current Pmts BUILDING - NONRES 000/322.100 .20 ELECTRICAL PLAN - NONRES 000.345.832.00.0 135.30 PLAN CHECK - NONRES 000/345.830 1,744.61 TOTAL: 1,880.11 • Payment Date: 02/05/2008 Total Payment: 1,880.11 1,880.11 1,880.11 2098 02/05 0710 TOTAE.. 1880.11 Project: a � � Type of Inspection: ►N A L Address: 2 ( I—) 1.,. 1'1 1 v; t 1 Date Called: Special Instructions: Date Wanted: 7_ zz - .3 a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V G-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 El - Approved per applicable codes. Corrections required prior to approval. COMMENTS: , Per 4 ► / 4 f � ( 1 1 0 `'r ( k rl to c El $60 .01 REINSPECTION EE REQUIRED. Prior to inspection, fee must be pair 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: a) S ?,s /-) V, 4.) flo .. /,,./ - d j L p2 /Ai e.. - 1 - 1 / 01). - 444-- d _ °2 f > i .1 .4,rl I d/ . _ O p1.9/�, Date Called: �Tl� /� — i 1 ,"ire" Special Instructions: Date Wanted: 7 z 2- E. a.m. Requester: �a %pii 6n 1/ 4 le-f- ,,4,r9 / o, -6 , vo y ,4",, fc i I. Project: Type nspectio - \1/4.: Address: 2 &56 1•0, 19/ / Date Called: Special Instructions: Date Wanted: 7 z 2- E. a.m. Requester: Phone No: /Q INSPECTION NO. - CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 N Approved per applicable codes. Corrections required prior to approval. INSPECTION RECORD Retain a copy with permit 6.50 PERMIT NO. (206)431 -3f7 Date: 7 Z7 0 REINSPEC ION FEE f QUIRED /Prior to inspection, fee must be d at 6300 Southcenter Blvaa , Suite 100. Call to schedule reinspection. R eipt No.: 'Date: Project:g Type of Inspection: / Address: Date Called: Special Instructions: Date Wanted: / ,, % l` 0.t �Requester: p.m. Phone No: 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION W- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 p Approved per applicable codes. El Corrections required prior to approval. COMM IS: �� (G 51o.FF 5h-t- Q'ry Inspector: 'Date: 6 0.00 R SPECTION FEE REQUIRED. P rior to inspection, / � � ri $ pection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: L F/ AM Addcess; 5 M 9 /1 Instructions: r/ 1) e ' / 4fil, 0 ( Welko Special .. 27 11.117, '.,S (2 /fir f„, S R / a p.m. 72 r7r ok 1_, 5 1 1-.1.2. 4'`‘' Veil/ 's.g../ rr //�� // / 4 I'�� U6, �,•�+r Pit G 9 �a • Gil �ffti�(r�� S P1b 5 9t 0.1- I CSI« F2,. a,. :rift,* PL'c Arr 11.- -> vQ Nieri 549 /541- Project, ER /e .. lT�l Type of Inspection: L F/ AM Addcess; 5 M 9 /1 Instructions: r/ Date Called: Special .. Date Wanted: 7--/ d a p.m. Requester: Phone No: 56 .3 - 70 e f eg,S INSPECTION RECORD Retain a copy with permit De& - 6 5 0 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. Inspector: Date: n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: _. A Type of Inspection: 5 a5f- Cer.i. Addres ^� � �/ �r Date Called: Special Instructions: 2.� 10s Date Wanted: / 7- 08 Requester: -- Phone No: 5b 37,010 g/ilS 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING D.1VI5ION D e 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- Approved per applicable codes. p Corrections required prior to approval. COMMENTS: . 7P4 (N'e ( f "c4x/rx (,e gired - t - c• c C .e 1d5 Inspecto, 1 / f , (Date: /z /e.J) El $604 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pJ at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: es „4w:n ".� a.w6...ewa..01.abk .as .8614: -�. .ktien Project: 4 Type of Inspection: Address: Date Called: ./ Special Instructions: Date Wanted: } s/ / a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. y CITY OF TUKWILA BUILDING DIVISION I', 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: /D /A CG! A ql /d , 4- ) cove b1rx_rrill A ,a..r.e cr S Inspector: 0 $58.0 S PECTION FEE REQUIRED. Prior o inspection, fee must be paid 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: (Date: Project: Type of Inspection: Address: f c2( PIC1O/ Date Called: Special Instructions: Date Wanted: m: Requester: Phone No: .?6D - aN' INSPECTION NO. INSPECTION RECORD Retain a copy with permit dag PERMIT NO. $58.0 INSPECTION FEE REQUIRED. Prior to inspection. fee must be paid a 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. } CITY OF TUKWILA BUILDING DIVISION ir--• 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: p/ comet '00 a e_ — #urc4lr}1i- 1 t t • alf1roverj Inspector: Date// 9 , Receipt No.: Date: e . 7 s i x;._ .! .. •• • Project: �r r, F. Type of Inspection: FO /ti4. Add . 65 6 l'n A / / Date Called: Special Instructions: .i Date Wa ted: m. Requester: Phone No: _ 2 60 , — i0 — 67 /eg INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. I (206)431 -3670 R Corrections required prior to approval. :loss 7 fr` 4 Lac] I el Alter C.)4 ,AP,I• 17, Of' frex/ e- COMMENTS: Date: 5 ./ 13 � 0 $58. INSPECTION FEE REQUIRED. Prior to inspection. fee must be pai t 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: ee CO tr COMMENTS: gi 9 4.4 s -/•et n,,. , t „,d is ,o �Jn / Ile s4.,, 1 / , •/, CV,lithe c1 i4. y Special Instructions: Date Wanted: Cm. -_. — Q2 p.m. Requester: Phone No: 360- go ) --67J ( Project� Type of Inspection: . Address: c2f5(.a. /1/4 // Date Called: Special Instructions: Date Wanted: Cm. -_. — Q2 p.m. Requester: Phone No: 360- go ) --67J ( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. LJ Corrections required prior to approval. l� Inspector: Date: 1)06 - a-C: $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: (Date: Project: � �'r/ Type of Ins ection: /-.� A i27 //V �� Address: a656., /77 4 1' Date Called: Special Instructions: Date Wanted: s- 2 - oe m, Requester: P _7 - 3J va8 - 6661 INSPECTION RECORD Retain a copy with permit ECT •N NO. PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION Approved per applicable codes. Corrections required prior to approval. COMMENTS: pA ..Z/!1c /;or - cricwv ;1. A "eel r. a1e'› ae4 Inspector�� /J� Date: s ./ 7 / 5,00 / El $58 ; i EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: Type of Inspection: Address � / Date Called: Special Instructions: Date Wanted: 9.- � — OP a.m. Requester: Phone No: 30.7— 7c1 3 / INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA'BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: FM co dor- 4. i . f ,r Date: ..� $58.0', INSPECTION FEE REQUIRED. Prior to inspection. fee must be paid ? 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: (Date: Project: Type of !Ruction: 1-1(' --(lefiuoivio Address : 6,56 in 1 / Date Called: Special Instructions: Date Wagte i ..67t. / it Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit ' MIT NO. CITY OF TUKWILA BUILDING DIVISION 1�- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 CO NMA ENTS: a� -u. _:27710/9,640x.1 cs 'motC_C nsp ctor: 114 $ :.0 REINSPECTION FEE R. QUIRE. Prior o inspection. fee must be ai. at 6300 Southcenter Blv• . Suite 100. Call the schedule reinspection. Recd' • t No.: Date: Approved per applicable codes. Corrections required prior to approval. Project: acme Sprinklers: Type of Inspection: PA c tr-- / E i m Address: 1(0SGa ', Suite #: Mki-' -- Contact Person: Special Instructions: Occupancy Type: Phone No.: Needs Shift ' ns ion: - Sprinklers: Are Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East Tukwila, Wa. 98188 206 - 575 -4407 COMMENTS: nspector• (.9 roved per applicable codes. 17,4c41., 6.t - Q INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word/Inspection Record Form.Doc 1/13/06 Doe -- 04D PERMIT NUMBERS Corrections required prior to approval. Date: 7 ('7 /o Hrs.: 1 $81.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. CaII to schedule a reinspection. T.F.D. Form F.P. 113 Project: Sprinklers: Fire Alarm: Type of Inspection: Address: <lc s -i 7 Suite #: S, /04-uL Contact Person: Special Instructions: Phone No.: Needs Shift Ins. - :ion: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER • CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 COMMENTS: irgli kOh'Mt2ki3' s1fvn..'. /Approved per applicable codes. O g. `f'D S tuff- INSPECTION RECORD Retain a copy with 1,ermit i /l cog- or 8- as PERMIT NUMBERS n Corrections required prior to approval. Inspector: . '57 Date: 7//4 Hrs.: ri $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: Type of Inspection: Address: � Suite #: S , L . yvn,,4-L Contact Person: Special Instructions: Occupancy Type: Phone No.: - Needs Shift Ins - :ion: S Sprinklers: Are Alarm: H Hood & Duct: Monitor: P Pre -Fire: Permits: O Occupancy Type: a-pg, t.glAr9 INSPECTION NUMBER COMMENTS: ti . Inspector: 51 l/ E4 ..Approved per applicable codes. 1 INSPECTION RECORD Retain a copy with permit Word/Inspection Pecord Form.Doc 1/13/06 6' - 5- 1.5 2: PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 ri Corrections required prior to approval. ataillgft2=2131MMROOrz.. 416:1. Date: ~7))6,kfj at ri $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Hrs.: T.F.D. Form F.P. 113 Project: Q t� M 1 Sprinklers: Fire Alarm: Type of Inspection: r� r c � e ( � I,,! ,fr) e fr Address: ; �S� Suite #: S ( MA L 1. _ Contact ersor .SO VO J Special Instructions: Phone No.: 3 n - - 7 a- 2-7 a s Needs Shift Ins . ection: Sprinklers: Fire Alarm: Hood& Duct: Monitor: ... Permits: Occupancy Type: 3 INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 FA Xpproved per applicable codes. COMMENTS: ki et L I.1 r kJ- Inspector: s r y INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 Poe - (S ) PERMIT NUMBERS n Corrections required prior to approval. In $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Cali to schedule a reinspection. T.F.D. Form F.P. 113 Date: 7/ ?/ Hrs.: t COMMITS: Type of Inspection: . _S Ce1NIzL -L1— fly, - - ro CO%dk: Address: - 2ja , ,=, Suite #: Contact Person: C ,- i-e•An • W , Cl . Special Instructions: i 1 Sea_ ►i1 picit N(, or.' A(t VAE ?_2. A iktES, C UT 5++W:C1', 4•61UtRCD fay P 2i - Tt1 ) PL'! OOc ..• .lam/} !_r'_..� ►{�'��° ..MS .��r'7" "e ^•v �ev4.s- ..�:.- r -s -� r •r�arr --a. ,r _ . r .,. * . p . 41 .�; j • 'Lr Project: 01 -r G % Type of Inspection: . _S Ce1NIzL -L1— Fire Alarm: Address: - 2ja , ,=, Suite #: Contact Person: C ,- i-e•An • W , Cl . Special Instructions: Phone No.: L4 25 - 33(- oz.i - i Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: a .. . . - y.... u P • • . . •rissi a• 2_ INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 proved per applicable codes. Inspector: .e..4,1,r,.. :.... INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Date: , 9 _ o g Hrs.: eis./s - ea- - BS PERMIT NUMBERS ri Corrections required prior to approval. pi $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaH to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project Info Projec:tAddress AEIRE Date 1/29/2008 SOUTHCENTER MALL SPACE 2120 For Building Department Use TUKWILA, WA Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 -410 -2858 ?rojectSum'm 2006 Washington Slate Nonresiden■al Energy Code Compliance Forms EXPIRES 2006 Washington State Nonresidential Energy Code Compliance Form EC 2 0 2009 FILE COPY Permit No. REVIEWED FOR CODE COMPLLgNCE APPROVED MAR 21 208 Rev+sed July 2007 RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER Project Info Project Address AEIRE Date 1/29/2008 SOUTHCENTER MALL SPACE 2120 For Building Department Use TUKWILA, WA Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 - 410 -2858 Project Description • New Building -' Addition ❑ Alteration -' Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option O Prescriptive Qo Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft Allowed x Area 1st Floor 118 Sales Area 1.50 3473.0 5209.5 1st Floor 440.0 Stockroom 0.50 382.0 191.0 1st Floor Rat Downlights Display lighting 1.50 2400.0 3600.0 1st Floor 27.0 Restoom /corridor 0.80 204.0 163.2 30.0 30.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 9163.7 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales Ha Trackhead 118 44.0 5192.0 Sales Ha2 Trackhead 10 44.0 440.0 Sales Ra Downlichts 18 26.0 468.0 Sales Rat Downlights 17 37.0 629.0 Sales Sa -34 Fluorescent Strip 2 27.0 54.0 Sales Sa -40 Fluorescent Strip 1 30.0 30.0 Sales Sa -50 Fluorescent Strip 3 39.0 117.0 Sales Sa -60 Fluorescent Strip 1 46.0 46.0 Sales Pa Custom Fixture 10 64.0 640.0 Sales Pa2 Custom Fixture 1 64.0 64.0 Sales Pa3 CusL om Fixture 1 64.0 64.0 Sales Pa 5 Custom Fixture 5 50.0 250.0 Sales Sa -4 Fluorescent Strip 8 30.0 240.0 Sales Sa -8 Fluorescent Strip 7 61.0 427.0 Stockroom Sa -4 Fluorescent Strip 6 30.0 180.0 Stockroom Sa -8 Fluorescent Strip 2 61.0 122.0 Restroom L Fixture 1 60.0 60.0 Corridor Sa -4 Fluorescent Strip 2 30.0 60.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 9083.0 Interior; Lighti 2006 Washmglon State Nonresidential E nergy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage Notes: 2006 Washington State Nonresidential Energy Code Compliance Form 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only. the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, may also be used I-orVIN #1 ,9gttc 7e lEdPterCW-cts Pi 11 k t 'Vf !*RPPPOgaFrRSl lied b 50, or as applicable, the watta of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number. and leave Watts /Fixture blank. Use' t LPA (W /sf) 0.9 Use Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions. museums, banks, churches) 7.11 LPA (W /sf) _ 1.0 Automotive facility Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias, fast food establishments restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retain'', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater. performing arts 1 6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation Warehouses", storage areas Workshops 1,0 0.5 1 Hotel /motel 1 2.0 Hotel banquet/conference /exhibition hall" Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0 Laundries 1.2 Libraries 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) Common areas, corridors, toilet facilities and washrooms, elevator lobbies 1.2 0,8 Museum 1.1 Prescriptive Spaces Occupancy: storage areas or aircraft storage hangers 0 Other Qualification Checklist lificati Chklist Lighting Check if 95% or more of fixtures comply with 1.2 or 3 and rest are ballasted. Note If occupancy type is "Other' and fixture Fixtures: answer is checked, the number of fixtures In (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector the space is not l,mited by Code Clearly 1521) or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- indicate these spaces on plans If not tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified, do LPA Calculations 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. .Interior;Lighti' 2006 Washington Stale Nonresidential Energy Code Compliance Forms g Summary (back) TABLE 15 -1 Unit Lighting Power Allowance (LPA Revised July 2007 oo for Ta 1 5 O - 2006 Washington State Nonresidential Energy Code Compliance Form 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified In the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and iDffices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window. provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional fighting power is allowed only if the lighting is actually installed 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height alloNance defined in footnote 2 applies only to the floor area not covered by racks. Project Info Prof Addres AEIRE Date 1/29/2008 SOUTHCENTER MALL SPACE 2120 For Building Department Use TUKWILA, WA Name: DON PENN CONSULTING ENGINEER Appl Name 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Appl.Phone617 -a10 -2858 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 2006 Washington State Nonresidential Energy Code Compliance Form .Exterior Lighti g - Summ 2006 washinglon Slate Nonres denI al Energy Code Compliance Forms Compliance Option Building Grounds (luminaires > 100 Watts) Alteration Exceptions (check appropriate box - sec. 1132.3) Tradable Proposed Lighting Wattage Non - Tradable Proposed Lighting Wattage O Lighting Power Allowance 0 Systems Analysis C) Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor ❑ Exemption (list) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage otal Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maxirnum Allowed Lighting Wattage y not exceed Allowed Watts for Category Total Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Total Proposed Watts Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W /ft Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft' Stairways 1.0 W /ft Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W/ft Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ft' Street frontage for vehicle sales lots in addition to "open area" allowance 20 Wilinear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior Building Facades 0.2 W /ft for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM .er location Entrances and gatehouse inspection stations at guarded facilities 1.25 W /ft` of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") lighting. The following allowances are in addition to any allowance otherwise Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") permitted in the "Tradable Surfaces" section of this table.) Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restaurants 400W per drive - through Parking near 24 -hour retail entrances 800 W per main entry 2006 Washington Slate Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 2006 Washington Stale Nonresidential Energy Code Compliance Forms Project Address AEIRE Location ((loorlroom no.) 2006 Washington State Nonresidential Energy Code Compliance Form r Allowance :Adjustments: Date 1/29/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Allowed Watts per ft Ceiling Height for this room Ceding Height limit for this exception" Adjusted LPA Watts per ft Occupancy Description " From Table 15 -1 based on exceptions listed in footnotes Revised July 2007 ag tang, Mot • r, and `Transformer Permit Plans., heckIist. LT G' CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address AEIAE Dat 1/29/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans , Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch yes 1513.3 Daylight zone control Schedule with type and features. indicate locations no vertical glazing Indicate vertical glazing on plans no overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w /backup Indicate location yes 1513.6 (b) photocell. Inter. auto shut -off Indicate location Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability), Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 'Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Surnmary Form Completed and attached. Schedule with fixture types, lamps. ballasts, watts per fixture yes 1532 Exterior Lighting Surnmary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes 1511 lElec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency 1 TRANSFORMERS (Section 1540) yes 1540 Transformers Indicate size and efficiency I 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form r, and'Transformer Permit Plans Checklist LTG CHK Washington State No ^residential Energy Code Compliance Forms Lighting - General Requirements 1513 Lighting Controls: Lighting, Including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513 6 1. INhere automatic time switches are cited, they shall have the features listed in Section 1513.6 2. 1513.1 Local Control and Accessibility: Each space. enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space- The lighting controls, whether one or more, shall be capable of turning off all lights within the space- The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole 2 Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the Individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1 Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 f1 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not Include zones facing more than two adjacent cardinal orientation:; (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting 1513.5 Automatic Shut - off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut - Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms. shall be equipped with occupancy sensors that comply with Section 1513 6 1 For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting EXCEPTIONS: 1 Areas that must be continuously illuminated (e g . 24 -hour convenience stores). or Rev'sed July 2007 illuminated in a manner requiring manual operation of the lighting 2. Emergency lighting systems. 3 Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off" feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -nde switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated, d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100.000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1 -2002) Project Info Project Address AERIE Date 1/29/2008 SOUTHCENTER MALL SPACE 2120 For Building Department Use TUKWILA, WA Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817-410-2858 Project,Sum_rn 2006 Washington Slate Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form FXPIRFS DEC 2 0 2009 Revised July 2007 Project Info Project AERIE Cooling Equipment Schedule Date 1/29/2008 Brand Name' SOUTHCENTER MALL SPACE 2120 Capacity Btu /h For Building Dept. Use OSA CFM or Econo? TUKWILA, WA IPLV Applicant Name: DON PENN CONSULTING ENGINEER TITUS Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 -410 -2858 Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Brand Name' Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location VAV -1 TITUS EESV 54354 3000 PLENUM treating Equipment Schedule E ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' PLENUM VAV - 1 TITUS EESV 54354 3000 10239.00 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washmgion Slaie Nonres densal Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Compliance Option Fan E Equip. ID Includes Plans quipment Schedu Brand Name' 'If available. 2 As tested accord ng to Table 14 -1A through 14-1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised July 2007 Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 QQ Simple System 0 Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple 8 complex systems.) le Model No CFM SP' HP /BHP Flow Control Location of Service System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vole ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20.000 Btuh? ❑ Economizer included? If Heating Only: < ❑ 5000 cfm . ° ❑ <70 /° outside air? =ZEE Decision Flowchart CSTART 1 J Heating Only No Complex Systems <5000 > Yes cfm? 2006 Washington State Nonresidential Energy Code Compliance Form Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Reference Section 1421 Heating /Cooling or Cooling Only ingle Package Yes Unit? <70% OSA j> Yes,. Included?. Yes Reference kection 1423) 7 Simple System C I F Allowed (section 1420) Air Cooled. Constant Vol? Yes /total Ca <N two econom z e�� <240,000 Btuh Nor 10 %? Yes - -- Yes- No or Adjacent to Qutdoo — ool Ca <54,000 Btuh' No— I Use Complex Systems (section 1430) Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Project Info Project Address AERIE Cooling Equipment Schedule Date 1/29/2008 Brand Name' SOUTHCENTER MALL SPACE 2120 Capacity Btu /h For Building Dept. Use OSA CFM or Econo? TUKWILA, WA IPLV Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 617 -910 -2058 Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Brand Name' Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location Heating Equipment Schedule E ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency" Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM Spy HP /BHP Flow Control Location of Service ec anical 2006 Washington Stale Norresdentiai Energy Code Comphance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Compliance Option 2006 Washington State Nonresidential Energy Code Compliance Form mmary, MECH;SUM ReYr d July 2007 Include documentation requiring compliance with commissioning requirements, Section 1416. O Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: • Constant vol? D Air cooled? Packaged sys? Lj <20,000 Btuh? Econom•7.er included? Split system? If Heating Only: y: <5000 cfm? <70% outside air? 117121=BE Decision Flowchart ( START ) System Type S Heating Only <5000 - Yes fm? / No z 0% OSA} Yes Y Complex Systems 2006 Washington State Nonresidential Energy Code Compliance Form ,ummary (bai k)1: Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. r Reference — ) Section 1421 J Heating /Cooling or Cooling Only Yes S imple System _.�. Allowed (section 1420) ----Yes -� Referenc� Section 1423) Yes otal Ca.. wo economize <240,000 Btuh or 10 %? <20.000 Btuh? \/ Yes Yes No plit Syste <= 84,000 Btuh?,, Outd or Adjacent to "Qutd00r Yes–I Use Complex Systems (section 1430) Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project INZZIMMIZEoMplex Systems' Checklist° = , ,... .j ' . .:, • • MECH =C;OMP 2006 Washington State Nonresidential Energy Code Comp:once Forms Revised July 2007 Project Address AERIE Dat 1/29/2008 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative For Building Department Use Applicability (yes. no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY yes 1431.1 Field assem. sys. Provide calculations n.a. 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset n.a. 1432.2.2 Hyclronic System Indicate automatic reset, cooling tower, & heat pump loop valves n. a. 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. no 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized no 1434 Separate air sys. Indicate separate systems on plans yes 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified no 1436 Heat recovery Indicate heat recovery on plans: complete and attach heat recovery calculations n.a. 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency n.a. 1 438 Variable flow sys. Indicate variable flow on fan and pump schedules n.a. 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air n.a. 1439.2 Fume Hoods Indicate VAV, unheated /uncooled or heat rec. makeup Decision Flowchart L Start Here Section 1411 1 Equipment Efficiency Shall Meet Tables L 14 -1A through 14 -1G as /OiI Furnac input ? 225,000 tuh or Gas /OjV t Heat Yes 2006 Washington State Nonresidential Energy Code Compliance Form 1411 1 intermittent Ignition Device 8 Power Venting or Damper If input > 225,000 Bluh then 1412 6 Moculabng or 1 Staged Combustion Controls Required Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. ny Fuel Fumac input > 225,000, Bluh7 Yes 1411 1 0 75% Maximum Jacket Loss II J Yes 1 Section 1431 1 Calculations of Total On -Site Energy Input 8 Ouput Required r (continued on back) 1 Yes Section 1432 2 1 Supply Air Reset I - - -- Controls Required apaclty of H Nq- -< Heating System > - 00.000 Bt Yes Section 1432.2.2 Hot Water Supply Temperature Reset Required No eclanica Yes 2006 Washington State Nonresidential Energy Code Compliance Form {" MECH-COMP� omplex�S��ystems � ��; �� � * -;:� 2006 Washington State Nonresidential Energy Code Compliance Forms 0% Air Ecori Provided? Section 14137 No N i Water Cooled w/Water Econo j Yes Total CigN Capacity w/ N Water Econo 0 <500 Tons? pply Air >5,0 cfm &OSA> 70% Yes ►f Yes ystem or Zone < w/ Simultaneous Htg 8 Clg ? No Z Z'ApplicabonN, Involves Variable \ Flow? No 7 to al Bldg Fu Exhaust > 15,000 cfm? No / Kitchen Exhau Hood > 5,000 cfm? No DONE _Ye -- Yes S EER 10% Better' than Code 7 l Yes tal Cap /tq / 4cono <= 480,00 Btuh or 20% of otal Cap ? Yes Section 1436 50"/ Effective Heat Recovery Required j ,Motor Intl gpmt Covr'd by Multi - speed \ Tbl 14.1A -14- j No i M otor n Multi- j No ► N 1G? / Aeed system?. NZ Yes 1 Section 1435 1 Zone Controls Must - Yes -• Reduce Supply Air Quantity Before Reheating /Recooing T N Yes- 1..< ' ans or Pumps 10 HP? Yes No Section 1439 1 No Heating or Cooling for at Least 50% of Make -up Air Yes • 7 Section 1433 Economizer Required 1 Yes Yes Section 1437 Motors Must Meet Efficiencies in Table 14 -4 I J Yes Section 1438 Yes- 0- Variable Flow Devices Required L Yes Section 1439 2 One Required a 50% VAV Exhaust 8 Make -up b. 75% Direct Makeup w/ Tempering Only c Heat Recovery per 1436 d Constant Volume w/ < 50fpm Face Velocity Revised July 2007 Open Motors Closed Motors 3,600 '1.800 1,200 3.600 1,800 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86 5 85.5 87.5 87 5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 .38.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 924 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91,7 93.0 93 0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93 0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95 0 ectric Mot 2006 Wash nglon Staid Nonres Project Address Complete the following for all design A 8 B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location Minimum Nominal F Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP 2006 Washington State Nonresidential Energy Code Compliance Form r MECH -MOT AERIE Type (open /closed) 'ull -Load Efficienc Description of Application or Use Date 1/29/2008 For Building Department Use Synch. Speed Min. Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14 -1B). 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e if the only U L listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. denial Energy Code Compliance Forms Revised July 2007 n. a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 Jiff. day types yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n. a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule yes 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas yes 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Hurnidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary yes 1414.2 Duct insulation Indicate R -value of insulation on duct yes 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Cornpletion Requirements yes 1416.2.1 Commissioning Provide commissioning plan yes 1416.2.2 -3 Sys Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commission ng Indicate O &M manuals, record drawings, staff training yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report yes 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICEWATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank yes 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping n. a. 1452 Heal Pump COP Indicate minimum COP of 4.0 yes 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover apical P Project Address The following information is Washington State Nonresid Applicability (yes, no, n.a.) HVAC REQUIREMEN yes yes n.a. n.a. n.a. Code Section 1411 1411.4 1411.1 1411.1 1412 1412.1 1412.2 .a. 1412.3 2006 Washington Slave Nonresidenhal Energy Code CompIonce Forms 2006 Washington State Nonresidential Energy Code Compliance Form Component TS (Sections 140 Equipment perform Pkg. elec. htg.& clg. Minimum efficiency Combustion htg. HVAC controls Temperature zones Deadband control Humidity control rmit Plans': Checklis MECH`; K. CH mechanical permit application for compliance with the mechanical requirements in the Information Required 1 -1424) nce List heat pumps on schedule Equipment schedule with type, capacity, efficiency Indicate intermittent ignition, flue /draft damper & jacket loss Indicate locations on plans Indicate 5 degree deadband minimum Date 1/29/2008 Location on Plans Building Department Notes AERIE necessary to check a ential Energy Code. Indicate humidistat , explanation: Revised July 2007 Washington Slate Nonresidential Energy Code Compaance Forms 1411.4 Packag equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service lacd�bes. 1412 Controls 1412.1 Temperature Controls: Each 1 ystem shall be provided with at least one temperature control device Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone At a minimum, each floor of a building shall be considered as a separate zone 1412.2 Deadband Controls: When used to control both comfort heating and cooling. zone thermostatic controls shall be capable of a deadband of al least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum Exceptions: 1 Special occupancy, special usage. or code requirements where deadband controls are not appropriate 2 Buildings complying with Section 1141 4, If in the proposed budding energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 7C degrees F and 75 degrees F Inclusive. and assumed to be constant throughout the year 3 Thermostats that require manual changeover between heating and cooling modes 1412.3 Humidity Controls: If a systems equipped with a means for adding moisture, a humidistat shall be provided 1412.4 Setback and Shut -OH: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback Or equipment shutdown during periods of non -use or alternate use of the spaces served by the system The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours Exceptions: 1 Systems serving areas which require continuous operation at the same temperature selpoint 2 Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system Exceptions: 1 Systems serving areas which require continuous operation 2 Combustion air Intakes 3 Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets it the first story and levels below the first story of buildings three or more stories in height 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2006 Washington State Nonresidential Energy Code Compliance Form ecl `pical, Per Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G 112 nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it Includes provisions for verification and challenge of equipment efficiency ratings. then the product shall be listed in the certification program Gas -fired and oil -fired forced air furnaces with Input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an Intermittent ignition or interrupted device (HD), and have either mechanical draft (including power venting) or a flue damper A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the concitioned space All furnaces with input ratings > 225 000 Btu /h (65 kW), including elec :ric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0 75% of the input rating 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available Where no applicable procedures exist. data shall be furnished by the equipment manufacturer 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991 Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor EF) or a CAE of not less than the following Revised July 2007 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 112. have a design occi,oancy for ventilation of greater than 40 people for 1000 112 of floor area, and are served by systems with one or more of the following a An air -side economizer, b Automatic modulating control of the outdoor an damper, or c A design outdoor airflow greater than 3000 cfm Exceptions 1 Systems with energy recovery complying with Section 1436 2 Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3 Systems with a design outdoor airflow less than 1200 cfm 4 Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical Cooling Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer. at outside air temperatures of 45 ° F dry - bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures Exception Water economizers using air- cooled heat rejection equipment may use a 35 ° F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per budding 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information 1 Maximum outside air conditions for which economizer is sized to provide full cooling 2 Design cooling load to be provided by economizer at this outside air condition 3 Heat rejection and terminal equipment performance data including model number, flow rate, capacity- entering and leaving temperature in full economizer cooling mode 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load Exceptions: 1 Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling 2. Water- cooled water chillers with waterside economizer 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1 Health care facilities where WAC 246- 320.525 allows only steam injection humidifiers in ductwork downstream of final filters 1412 6 Combustion Heating Equipment Controls Combustion heating equipment with a capacity over 225.000 Btu /h shall have modulating or staged combustion control 2 Systems with water economizer 3 100% outside air systems with no provisions for air recirculation to the central supply fan 4 Nonadiabatic humidifiers cumulatively serving no more than 10% of a building s air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18 Extent of sealing required is as follows 1 Static pressure 1/2 inch to 2 inches. seal transverse joints 2 Static pressure 2 inches to 3 inches, seal all transverse joints and longitudinal seams 3 Static pressure above 3 inches, seat all transverse joints, longitudinal seams and duct wall penetrations Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W C or greater 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the budding envelope. by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13 These requirements include insulation installation, moisture control, air leakage. and building envelope insulation levels Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13 Outside air ducts serving individual supply air units with less than 2 800 cfm of total supply air capacity shall be insulated to a minimum of R.7 and are not considered building envelope Other outside air duct runs are considered building envelope until they. 1 connect to the heating or cooling equipment, or 2 are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0 58 0.71 50 to 70 gal storage 0 57 0.71 > 70 gal storage 0 55 0 70 Washington Slate Nonresidential Energy Code Compaance Forms 1411.4 Packag equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service lacd�bes. 1412 Controls 1412.1 Temperature Controls: Each 1 ystem shall be provided with at least one temperature control device Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone At a minimum, each floor of a building shall be considered as a separate zone 1412.2 Deadband Controls: When used to control both comfort heating and cooling. zone thermostatic controls shall be capable of a deadband of al least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum Exceptions: 1 Special occupancy, special usage. or code requirements where deadband controls are not appropriate 2 Buildings complying with Section 1141 4, If in the proposed budding energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 7C degrees F and 75 degrees F Inclusive. and assumed to be constant throughout the year 3 Thermostats that require manual changeover between heating and cooling modes 1412.3 Humidity Controls: If a systems equipped with a means for adding moisture, a humidistat shall be provided 1412.4 Setback and Shut -OH: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback Or equipment shutdown during periods of non -use or alternate use of the spaces served by the system The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours Exceptions: 1 Systems serving areas which require continuous operation at the same temperature selpoint 2 Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system Exceptions: 1 Systems serving areas which require continuous operation 2 Combustion air Intakes 3 Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets it the first story and levels below the first story of buildings three or more stories in height 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2006 Washington State Nonresidential Energy Code Compliance Form ecl `pical, Per Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G 112 nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it Includes provisions for verification and challenge of equipment efficiency ratings. then the product shall be listed in the certification program Gas -fired and oil -fired forced air furnaces with Input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an Intermittent ignition or interrupted device (HD), and have either mechanical draft (including power venting) or a flue damper A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the concitioned space All furnaces with input ratings > 225 000 Btu /h (65 kW), including elec :ric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0 75% of the input rating 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available Where no applicable procedures exist. data shall be furnished by the equipment manufacturer 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991 Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor EF) or a CAE of not less than the following Revised July 2007 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 112. have a design occi,oancy for ventilation of greater than 40 people for 1000 112 of floor area, and are served by systems with one or more of the following a An air -side economizer, b Automatic modulating control of the outdoor an damper, or c A design outdoor airflow greater than 3000 cfm Exceptions 1 Systems with energy recovery complying with Section 1436 2 Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3 Systems with a design outdoor airflow less than 1200 cfm 4 Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical Cooling Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer. at outside air temperatures of 45 ° F dry - bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures Exception Water economizers using air- cooled heat rejection equipment may use a 35 ° F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per budding 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information 1 Maximum outside air conditions for which economizer is sized to provide full cooling 2 Design cooling load to be provided by economizer at this outside air condition 3 Heat rejection and terminal equipment performance data including model number, flow rate, capacity- entering and leaving temperature in full economizer cooling mode 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load Exceptions: 1 Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling 2. Water- cooled water chillers with waterside economizer 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1 Health care facilities where WAC 246- 320.525 allows only steam injection humidifiers in ductwork downstream of final filters 1412 6 Combustion Heating Equipment Controls Combustion heating equipment with a capacity over 225.000 Btu /h shall have modulating or staged combustion control 2 Systems with water economizer 3 100% outside air systems with no provisions for air recirculation to the central supply fan 4 Nonadiabatic humidifiers cumulatively serving no more than 10% of a building s air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18 Extent of sealing required is as follows 1 Static pressure 1/2 inch to 2 inches. seal transverse joints 2 Static pressure 2 inches to 3 inches, seal all transverse joints and longitudinal seams 3 Static pressure above 3 inches, seat all transverse joints, longitudinal seams and duct wall penetrations Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W C or greater 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the budding envelope. by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13 These requirements include insulation installation, moisture control, air leakage. and building envelope insulation levels Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13 Outside air ducts serving individual supply air units with less than 2 800 cfm of total supply air capacity shall be insulated to a minimum of R.7 and are not considered building envelope Other outside air duct runs are considered building envelope until they. 1 connect to the heating or cooling equipment, or 2 are isolated from the exterior with an automatic shut -off damper complying • 2006 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2 are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls Optimum with Section 1412 4 1 start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements. any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements immediately before scheduled occupancy The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 5 minimum. be a function of the difference between space temperature and occupied Exceptions: setpoinl and the amount of time prior to scheduled occupancy 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include 1 W thin the HVAC equipment. microprocessor controls that minimize supplemental heat usage during start-up, set- 2. Exhaust au ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3 Exposed ductwork within a zone that serves that zone compression heating as the first stage of heat Controls shall indicate when 1415 Piping Systems supplemental heating is being used through visual means (e g , LED indicators) 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6 1412 6 Combustion Heating Equipment Controls Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225.000 Btu/h shall have modulating or staged combustion control. 000 Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS 1 Boilers 2. Radiant healers 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing. including but not limited to. dampers, temperature and for complete text and guidelines for building Completion and commissioning pressure test connections and balancing valves requirements ) February 12, 2008 Scott Daves Permits Today, Inc 140 South Lake Avenue, Suite 323 Pasadena, CA 91101 RE: CORRECTION LETTER #1 Development Application Number D08 -050 Aerie — 2656 Southcenter Mall Dear Mr. Daves, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Dave Larson, at 206 - 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, 1 / :4 Brenda Holt Permit Coordinator encl xc: File No. D08 -050 City of Tukwila Department of Community Development Jack Pace, Director P :Perrnit Cen ter \Correction Letters\2008\D08 -050 Correction Ltr #1.DOC wer • • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 f • Building Division Review Memo Date: February 11, 2008 Project Name: Aerie Permit #: D08 -050 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner ; The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Detail C on sheet A.0.la is missing the 18 inch vertical grab as required by section 604.5.1 of ICC /ANSI A117.1 -2003. Please modify this detail to include vertical grab bar. 2. Notes were added to eliminate vertical mullions between storefront glass panels. Please show compliance with section 2403.2 of 2006 IBC. 3. Please provide a means of egress plan. This plan should show a shaded path connecting the two exits. This path must be within 30 feet of the most remote point of any merchandise pads. See section 1014.4.2 IBC. This path will need emergency lighting along its entire length at intensity levels per section 1006 IBC. Please show emergency lighting located above the means of egress path close enough together to comply with required lighting levels or add a note that requires the contractor to install emergency lighting per section 1006 IBC above this path. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • 0 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -050 DATE: 03 -05 -08 PROJECT NAME: AERIE SITE ADDRESS: 2656 SOUTHCENTER MALL DEPARTMENTS: t 41 Bu�dfig vi Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Approved Notation: _ Original Plan Submittal X Response to Correction Letter # 1 n Documents/routing slip.doc 2 -28 -02 J TUES/THURS R ,UTING: APPROVALS OR CORRECTIONS: Fire Prevention Structural Incomplete Please Route Structural Review Required REVIEWER'S INITIALS: DATE: Approved with Conditions n u REVIEWER'S INITIALS: DATE: Response to Incomplete Letter # Revision # After Permit Issued Planning Division Permit Coordinator DUE DATE: 03 -06 -08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required n DUE DATE: 04 -03 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -050 DATE: 02 -04 -08 PROJECT NAME: AERIE SITE ADDRESS: 2656 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bin �. � col ding division V -ot P ublic Work 1 2 b$ Complete Comments: TUES/THURS ROUTING: Please Route Documents routing slip.doc 2 -28 -02 ' COORD COPY • PLAN REVIEW /ROUTING SLIP C�J APPROVALS OR CORRECTIONS: 511 A14)(/ ti -fi o8 Fire Prevention cx] Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Structural Review Required LETTER OF COMPLETENESS MAILED: M& Planning Division ❑ Permit Coordinator REVIEWER'S INITIALS: DATE: DUE DATE: 02-05-08 Incomplete 1 Not Applicable Permit Center Use Ondy INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 03-04-08 Approved Approved with Conditions ri Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 2' 1 1 - 70 � Departments issued corrections: Bldg [I Fire ❑ Ping ❑ PW ❑ Staff Initials:g 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. • 1 City of Tukwila Department of Community Development 15300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 'Web site: http: / /www.ci.tukwila.wa.us Date: 0. l i Ey Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: J- 6S U Project Name: Project Address: ,, 4' 5 ` v e(L (t1 0'l4 J � r Contact Person: 5 oL !i e 5 Phone Number: Ue v 11 cr.L Y1�121��1'1t,� ruto loot/ -- A O. I cithAIL �u l li c-n (k G 3It4s5 Clavves -- /1.2. 3 e SS I - u. - p. c- t Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \ applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director e":043. C, ,Ptf Summary of Revision: wtt,tWEb CITY OF r! 1smNnA MAR () 5 9nna • 'Lt4 : Sheet Number(s): 1X.0 0 bi ( CAVA LI COL 4 - d GII a. z. 0 . 3 "Cloud" or highlight all areas of revision including date of revi 'on PH 724.776.4857 January 17, 2008 City of Tukwila Building Division/ Permit Ctr 6300 SouthCenter B1 Suite 100 Tukwila, WA 98188 • AMERICAN EAGLE OUTFITTERS Re: Tenant Improvement Letter Tenant Improvement permit for Aerie, Tukwila Permit No. , is issued subject to the following conditions: Final Inspection approval of this permit and approval of occupancy for the herein named tenant space will not be issued until the "shell" Building Permit No. D06 -147 has received final inspection approval from the Building Division. This condition is hereby acknowledged by: . Bezek onstruction Aerie by AE Outfitters Retail Co. FX 724.7 9.5580 150 Thorn Hill Drive, Warrendale, Pennsylvania 15086 -7528 ae.com AMERICAN EAGLE OUTFITTERS Kind of Fixture Fixture Units No of fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 — Shower, per head 2 2 -- Dishwasher 2 2 ---- Drinking fountain (each head) 1 .5 / Hose bibb (interior) 2.5 2.5 / Clotheswasher or laundry tub 4 2 Sink, bar ortavatory. 2 1 / Sink, Clinic flushing 8 8 r. Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 '"' Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 — Urinal, waterless 0 0 --- Water closet, tank or valve, 1.6 GPF 6 3 / Water closet, tank or valve, >1.6 GPF 8 4 — Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print of ( . 3 .a c ,, Property Street Address , Lt 6 1 City Stale ZIP Aei L:6 Owner's Name • Subdivision Name L — ) '` _ -ti-r__ � • } ict ;2/ # Subdiv. # Block # Building Name Ski L.% i % ..'r 1.; i _IJ ).:c. t... -- Of applicable) ( 1`; Ly ) 7 ' 7i y . 1�-" 7 , Owner's P one Number (with Area Code) City or Sewer District 4 " 1 w '/ f 4.4 1', {;._ - / et Date of Connection Property Contact Phone Number (with Area Code) Side Sewer Permit # Owner's Mailing Address , L•' �` • ! -. i ( - t. • A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units = [ RCE 20 L Print Name of Owner /Representative 1058 (Rev 11 /05) 1 For King County Use Only Account # Monthly Rate 6 Month Rate Property Tax ID # Party to be Billed (if different from owner) Demolition of pre- existing building? ❑ Yes S'No Type of building demolished Sewer disconnect date B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: ( " 1.:r tw1,• f r Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) = RCE 187 C. Total Residential Customer EqttlVt) (add A & B) CITY OFTUKWILA FEB 0 4 2008 PERMIT CENTER A B I RCE White - King County Yellow - Local Sewer Agency Pink - Sewer Customer King County Department of Natural Resources and Parks O eb Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi- annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner /Representative • r._.% l -'. �� Date License Information License NATIOBC962RG Licensee Name NATIONAL BUILDING CONTRACTORS Licensee Type CONSTRUCTION CONTRACTOR UBI 601990646 Ind. Ins. Account Id #4 Business Type INDIVIDUAL Address 1 1650 CARROLL AVE Address 2 City SAINT PAUL County OUT OF STATE State MN Zip 55104 Phone 6512221859 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/7/2004 Expiration Date 12/7/2008 Suspend Date Separation Date Parent Company Previous License NBCGECI011QC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date CORCORAN, WILLIAM B OWNER 12/07/2004 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #4 BANCINSURE INC B]WA24216A 11/01/2005 Until Cancelled $12,000.00 12/02/2005 #3 BANCINSURE INC B]WA22928A 11/01/2004 Until Cancelled 11/01/2005 $12,000.00 11/15/2004 Look Up a Contractor, Election or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. 0 Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= NATIOBC962RG 04/14/2008 • FIRE SUPPRESSION SYSTEM: TENANT AMERICAN EAGLE OUTFITTERS 150 THORN HILL DRIVE WARRENDALE, PA 15095 PHONE: 724 - 776 -4857 FIELD REPRESENTATIVE: MATT HLASTEN PHONE: 724- 779 -5269 FAX: 724 -779 -5580 CODE ANALYSIS PROJECT DESCRIPTION : USE GROUP CLASSIFICATION = - MERCANTILE OCCUPANCY LOAD CAPACITY: APPLICABLE BUILDING CODES: TENANT IMPROVEMENT - CLOTHING STORE SALES AREA (3,473) x 1 PERSON/30 SF = STOCKROOM (586) x 1 PERSON /300 SF = TOTAL OCCUPANCY LOAD = CONSTRUCTION TYPE: j 25 - UNPROTECTED, NONCOMBUSTIBLE SOUTHCENTER 633 SOUTHCENTER PARKWAY TUKWII,A, WA 98188 LANDLORD WESTFIELD CORPORATION 11601 WILSHIRE BLVD. 14TH FLOOR LOS ANGELES, CA 90025 TENANT COORDINATOR: JOSHUA KIMMEL PHONE: 310 - 893 -4761 116 PERSONS 2 PERSONS I16 PERSONS 2006 INTERNATIONAL BUILDING CODE w /WASHINGTON STATE AMENDMENTS 2006 INTERNATIONAL MECHANICAL CODE w /WASI.4INGTON STATE AMENDMENTS 2006 UNIFORM PLUMBING CODE N/ WASHINGTON STATE AMENDMENTS 2005 NATIONAL ELECTRICAL CODE 2006 INTERNATIONAL FIRE CODE w /WASI- 4INGTON STATE AMENDMENTS 2006 WASHINGTON STATE ENERGY CODE AREA DESCRIPTION SALES AREA FITTING ROOMS STOCKROOM TOILET ROOM(S) FIRE CORRIDOR OFFICE SQUARE FOOTAGE 5,040 433 284 63 141 GIB PERCENTAGE 'BREAKDOWN 75 % 11% 7% 2% 2 NO. DRAWING DESCRIPTION C5.0.1 COVER SHEET CS.O.la SITE PLAN 05.0.2 GENERAL NOTES CS.2.3 "AERIE" SCHEDULES AS.O.I ARCHITECTURAL SPECIFICATIONS A.0.1 FLOOR PLAN A.O.Ia TOILET ROOM DETAILS A.0.2 REFLECTED CEILING PLAN A.2.5 STOREFRONT ELEVATIONS A.2.4 PLAN SECTION 0 STOREFRONT NO. DRAWING DESCRIPTION A.2.6 COLUMN /CEILING /MISC. DETAILS A_2. FITTING ROOM DETAILS A.2.ga FITTING ROOM DETAILS A.2.gb CLOSET /3 -WAY MIRROR DETAILS A.2.I0 DOOR ELEVATIONS /HARDWARE A.2.II DISPLAY CASE DETAILS A.2_Ila DISPLAY CASE DETAILS A.2.12 SIGN SHOP DRAWING F.0.1 FIXTURE PLAN F.0.2 MISC. FIXTURE DETAILS NO. DRAWING DESCRIPTION M.0.2 MECHANICAL DETAILS M_0.20 MECHANICAL CALCULATIONS ES.O.I ELECTRICAL SPECIFICATIONS E.0.1 ELEC. REFLECTED CEILING PLAN E.0.2 ELEC. FLOOR PLAN E_O.3 ELEC. NOTES AND SCHEDULES E.0.3a ELEC. NOTES AND SCHEDULES A.2.4a PLAN SECTION 0 STOREFRONT A.2.4b PLAN SECTION @ STOREFRONT A_2.5 , STOREFRONT SECTIONS A•2.5a STOREFRONT SECTIONS A.2.5b STOREFRONT SECTIONS A - STOREFRONT SECTIONS A.2.5d STOREFRONT SECTIONS A.2.6 INTERIOR ELEVATIONS F.03 MISC. FIXTURE DETAILS F1.2 CASH AND WRAP DETAILS F.2.20 CASH AND WRAP DETAILS F.2.5 DAY BED DETAILS F.2.3a DAY BED DETAILS EP.O.I EGRESS PLAN 2 P.0_I PLUMBING SPECS 4 DETAILS EMS ENERGY MANAGEMENT SYSTEM COVER SHEET EMS.I EMS FLOOR PLAN /EMS DATA LINK EMS.2 RISER DIAGRAM DETAIL 615.3 INTERFACE PANEL EMS.4 HVAC CONTROLLER INPUT DETAILS EMS.S I-IVAC CONTROLLER DETAILS OUTPUTS FULLY SPRINKLERED - CONNECTED TO MALL'S MAIN. (SPRINKLER DRAWINGS TO BE SUBMITTED FOR PERMIT BY SPRINKLER CONTRACTOR.) TOTAL GROSS AREA AREA ANALYSIS 4, 05q INTERIOR TENANT FINISH :NY AUDIOVISUAL CONSULTANT ALARM/ANTI-THEFT CONSULTANT DMX MUSIC CONTACT: JUSTIN JOSE PHONE: 508 -439 -5002 100% PROJECT DATA 0.5 050 A_2.6a k2.7 A.2.7a E1TC INTERIOR ELEVATIONS PILASTER/VALANCE/FLOORING DETAILS PILASTER/VALANCE DETAILS 0 E GTE CHECKPOINT SECURITY CONTACT: JENNIFER DUBAY 952- 227 -5912 SENSORMATIC CONTACT: MITRE GIOSA 215 - 946 -8118 (PRIMARY) GARY SCOTT 724 - 263 -6305 (SECONDARY) DRAWING INDEX MS.0.1 MS.0.2 M.0.1 MECHANICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS MECHANICAL PLAN STORE NUMBER: 2751 SPACE NUMBER: 2120 SIGN CONSULTANT HANOVER SIGN 1771 PROGRESS AVENUE COLUMBUS, OH 43207 PHONE: 1- 800 -888 -4870 FAX: 614 - 4434809 EM36 GE SOFTW I RED CONTACTOR PANEL EMS.7 SOFTWIRING DETAILS /SCHEDULES EMS.S CO2, HUMIDITY, $ PIR WIRING DETAILS SEPARATE PERMIT REQUIRED R p M ec hanical Electrical {umbin9 Piping Citi al T� BUlainG OMS3014 VICINITY MAP S# \ 1 j s 154TH/ ST. Fi -Th ST. \ fj\ 5. 188 ST. VICINITY MA REVISIONS No changes shall b made to tho scope of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan submittal and may include additional plan review fees FILE COPY Permit No, ARCHITECT S T S. 183 ST. (8 r X08 ft 050 Plar review approval Is sect to errors and OMIS1 lon3. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and - y r . is aclaaowledgll d City of Tukwila BUILDING DIVISION KENNETH L. BUTTS, ARCHITECT 124 STAGECOACH ROAD BELL CANYON, CA 91307 PHONE: 818 - 999 -4272 FAX: 818- 999 -4321 bditiRECTION . 405 R CEIVED MAR 0 5 2008 PERMIT CENTER REGISTERED CHITE NN r ATE OF WASHINGTON REVISIONS; 7AA AAAAA Dawn W 0 t _ t l 4 I-I- z w UJ 00 U 0 co -j w w w (f) (I) j } In Ili c0 7 0 to 3 0 p LEVEL& 113131tI163e CAFE iacm 3/1363 PEfRE FlPP/tiia. CHIMEIFICCOLEMAWANT moron alITC&E33EFIACE NORDSTROM THREE LEVELS 171.275e OATH ancaea Wide 7EAlpPA18 MAIM Afo CFFICIL ima PERtEa PORTRAIT EnlEr1 wt>aitt M WA7C6zo i tPMTEAPpme., JUN10131 Memo. tax w01231e426 YOLNO Nem COMET= a FIVARVCE avant t mere wawa M/313 the 16'011E1e3 IMES FOUR LEVELS 2150.407V k AERIE SPACE NO. 2120 Level 2 Of 3 wwrlea PEMES MOM VIChInes scot 1373 awes AIM F e anal PCFe1RAIT anttao CHO3E115 PEWEE- CO Dogs Di5D Working Drawing Review Vc Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requlr- . to be kept on the RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER Wesme[c[ job site eta 11'2/28/^ U 7 Si•ned Date 0_ 77 5 1 Drawn r . Drawing No. CS.O.la RESPQNSIE3ILITY SCHEDULE ITEMS '9N 1J.sIQI FURNISHED INSTALLED . REMARKS TENANT aNIQ1aNvl io.aba.LNO7Imo 0 v co nnj.md .LMVN3J. OtIOICINV1 liolawurco Iwo J.1W UNO7 mum GENERAL REQUIREMENTS BARRICADE • • CONSTRUCTION GRAPHICS • • PERMITS AND FEES • • GROUT 4 MORTAR BED SY G.C. TEMPORARY HEAT • • TEMPORARY ELECTRIC • • IF REQUIRED TEMPORARY ENCLOSURE/NOISE/DUST PROTECTION • • CLEAN UP • • WOOD W/ BASE SHOE 0 • SITE WORK • • DEMOLITION • • CORE DRILL/TRENCH SLAB • • PAINT • • CONCRETE SLAB • • CONCRETE SLAB REPAIR • • • CONCRETE REINFORCEMENT • • MISCELLANEOUS CONCRETE WORK 0 • SUSPENDED A.T.C. (SALES AREA) • • MASONRY • • IF REQUIRED BY LANDLORD OR BUILDING DEPT. DEMISING WALL REPAIR • • MISCELLANEOUS MASONRY WORK • • METALS METAL STUDS 0 • DEMISING PARTITIONS 0 0 • • METAL STUDS ONLY (IF NOT EXISTING) INTERIOR PARTITIONS /SOFFITS/FURRING 0 • • SUPPLIED BY SIGN CONSULTANT SUSPENDED FRAMING FOR DRYWALL CEILINGS 0 • • COORDINATED BY G.C./INSTALLED BY AUDIO/VIDEO CONSULTANT STRUCTURAL FRAMING FOR HVAC • • COORDINATE LOCATIONS WITH FIRE MARSHALL MISCELLANEOUS STRUCTURAL FRAMING/METAL 0 0 • G.C. TO PROVIDE BLOCKING BENCH, BEAM BRACKETS AND COAT HOOKS • • TOILET ROOM MIRROR • • WOOD AND PLASTIC NOW BL.00KING/13L000ING (FIRE RETARDANT TREATED IF REVD.) 0 • • MOUNTING NAILERS FURN. BY TENANT PREFABRICATED WOOD PILASTERS AND COLUMNS • • PREFABRICATED WOOD VALANCES • • PAINT GRADE WOOD TRIM • • FITTING ROOM BENCHES • • FITTING ROOM MIRROR FRAMES • • • I NEW FPVAV W/ CONTROLS FITTING ROOM MIRRORS • • PLYWOOD AT ELECTRICAL/PFCNE/AUDIONISUAL PANEL BOARDS 0 • • PLYWOOD FOR STORAGE DECK FUN. BY TENANT PREFABRICATED CEILING SEAMS • • • MODULAR FITTING ROOM WALLS • • NO ROOF WORK REQ'D ROOF PENETRATIONS NO ROOF WORK REQ'D THERM. /MOIST. PROTECT. SEALANTS • • 1..,n� VAPOR !BARRIERS • • 1" PLUMBING 1 DOORS AND WINDOWS • • 1 DOORS • 0 ENTRY DOORS • • • DOOR GLAZING BY G.C. SALES /STOCK DOOR 0 • 1 FITTING ROOM DOORS • • L TOILET ROOM DOOR • • • COORDINATE WITH LANDLORD AND /OR POWER COMPAN SERVICE/EXIT DOOR • • _ • COORDINATE WITH LANDLORD AND /OR POWER =PAN DOOR HARDWARE • • • PROVIDE LABOR AND MATERIAL AS REQUIRED. STOREFRONT/FITTING RCM/TRANSOM t REAR CASE GLAZING • • • DELIVERY BUZZER SYSTEM REAR SERVICE DR. ER 1 • • BUZZER LOW VOLTAGE WIRING • • BRANCH CIRCUITING • • SERVICE DOOR ALARM LOCK (DETER) 0 • RESFONSIE3ILITY SCI- IEDULE ITEMS NIJ_sIxa FURNISHED INSTALLED REMARKS .LNVN3J. LANDLORD i i NOJOY2L1 VO: 311= 1N'VN3J. ONO1aNY1 i 1 FINISHES FLOORS HARDWOOD FLOORING ON SLEEPERS • • PORCELAIN TILE • • GROUT 4 MORTAR BED SY G.C. RESILIENT TILE FLOORING (VINYL TILE) • • MALL FLOORING • 0 IF REQUIRED DIVIDER STRIP/TRANSITION STRIP • • SASE WOOD W/ BASE SHOE 0 • VINYL (COVE) • • WALLS GYPSUM WALL BOARD • • PAINT • • SHIPLAP 4 BEAD BOARD WOOD PANELING • • MEDIUM DENSITY FIBERBOARD (MDF) • • CEILING GYPSUM BOARD • • SUSPENDED A.T.C. (SALES AREA) • • SUSPENDED A.T.C. (STOCKROOM) • • IF REQUIRED BY LANDLORD OR BUILDING DEPT. PAINT • • SPECIALTIES (EQUIPMENT * FIXTURES) FIXTURES, CABINETS AND ACCESSORIES 0 • WINDOW DECALS 0 • SIGNAGE 0 • SUPPLIED BY SIGN CONSULTANT AUDIONIDEO SYSTEM 0 COORDINATED BY G.C./INSTALLED BY AUDIO/VIDEO CONSULTANT 2A10BC FIRE EXTINGUISHERS • • COORDINATE LOCATIONS WITH FIRE MARSHALL CL05Er RODS AND SHELVES 0 • G.C. TO PROVIDE BLOCKING TOILET ACCE55ORIE5 • • TOILET ROOM MIRROR • • FURNISHINGS STOCKROOM SHELVING 0 • MISCELLANEOUS FURNITURE • • MECHANICAL HVAC UNIT, THERMOSTAT • • I NEW FPVAV W/ CONTROLS DUCTWORK • • DIFFUSERS AND GRILLES 0 0 CONTROL WIRING • • ROOF CURS NO ROOF WORK REQ'D ROOF PENETRATIONS NO ROOF WORK REQ'D SPRINKLER PIPING/MODIFICATIONS • • 1..,n� HEADS AND ESCUTCHEONS • • 1" PLUMBING 1 PLUMBING FIXTURES • • 1 ROUGH -IN AND FINAL CONNECTIONS • 0 WATER HEATER • 11--- 1 ELECTRICAL L SERVICE • • COORDINATE WITH LANDLORD AND /OR POWER COMPAN METER • • COORDINATE WITH LANDLORD AND /OR POWER =PAN PANELS • • PROVIDE LABOR AND MATERIAL AS REQUIRED. LIGHT FIXTURES AND LAMPS • • DELIVERY BUZZER SYSTEM REAR SERVICE DR. ER 1 • • BUZZER LOW VOLTAGE WIRING • • BRANCH CIRCUITING • • SERVICE DOOR ALARM LOCK (DETER) 0 • SECURITY 4 ANTI -THEFT SYSTEM FURN. /INST. BY OTHERS PHONE LINES (POINT OF ENTRY TO CASH WRAP) • • 1 TURN OVER REQUIREMENTS 1 I. THE CONTRACTOR IS TO ARRANGE FOR ALL INSPECTIONS AND FURNISH 714E STORE MANAGER WITH THE CERTIFICATE OF OCCUPANCY. ALSO, PROVIDE A LIST OF NAMES, ADDRESSES, AND TELEPHONE NUMBERS FOR ALL SUBCONTRACTORS, INCLUDING ALL OWNER PROVIDED SUBCONTRACTORS. BOTH ITEMS TO BE MOUNTED IN SEPARATE PICTURE FRAMES (8 1/2' x 11 °) ON TOILET ROOM PARTITION, ADJACENT TO DOOR AT 5' -0' A.F.F. TO BOTTOM OF FRAME AND ONE COPY OF EACH SHOULD GO TO TENANT'S DIRECTOR OF CONSTRUCTION. 2. PRIOR TO STORE OPENING, THE CONTRACTOR 15 TO ARRANGE FOR A CERTIFIED INDEPENDENT BALANCING CONTRACTOR TO BALANCE 1-I.V.A.C. SYSTEM. CONTRACTOR IS TO PROVIDE THE LANDLORD AND TENANT 141711 A COPY OF THE BALANCE REPORT. 5. IF REQUIRED BY LANDLORD, CONTRACTOR SHALL SECURE 714E NECESSARY APPROVAL OF STORES SPRINKLER SYSTEM FROM LANDLORD'S FIRE INSURANCE CARRIER. 4. TURN OVER ALL KEYS TO STORE MANAGER CLEARLY MARKING EACH KEY FOR IDENTIFICATION. 5. EXPLAIN OPERATION OF ALL MECHANICAL SYSTEMS TO STORE MANAGER. 6. INSTALL REMAINING OWNER SUPPLIED FIXTURES AND HARDWARE ARRIVING ON MERCHANDISE TRUCK. 7. GENERAL CONTRACTOR IS RESPONSIBLE TO PROVIDE TRASH CONTAINER FOR ALL INITIAL MERCHANDISE PACKING PRIOR TO STORE OPENING. 8. G.C. 51-1ALL REMOVE ALL EXCESS BUILDING MATERAILS FROM SITE PRIOR TO STORE OPENING. 1 GENERAL CEILING NOTES 1 1. COORDINATE THE WORK OF ALL TRADES INVOLVED IN T44E CEILING WORK TO INSURE CLEARANCES FOR FIX'T'URES, DUCTS, PIPING, CEILING SUSPENSIONS SYSTEM, ETC. NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECT'S DRAWING. 2. PROVIDE CEILING •ACCESS PANELS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATC1 -I ADJACENT CEILING FINISH U.O.N. 3. ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP OF FINISHED FLOOR TO BOTTOM OF FINISHED DRYWALL AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. 4. NOTIFY TENANT OF ANY CONFLICT5 OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, STRUCTURE, HVAC, AND /OR (E) CONDUIT, PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEEN ARCHITECT'S CEILING LOCATIONS AND ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE TENANT PRIOR TO FRAMING. 5. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ANY AND ALL OTHER APPLICABLE ITEMS. INSTALL APPLICABLE NEW PLUMBING, MECHANICAL FANS, DUCTS, CONDUITS, AND OTHER RELATED AND APPURTENANT ITEMS 50 AS NOT TO CONFLICT WITH LUMINARIES AND ANY AND ALL FIELD CONDITIONS. 6- INSTALL LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER, LENS, BAFFLE, AND THE LIKE, TO AVOID FIXTURE OILING OR DAMAGE, FIXTURES SHALL BE MAINTAINED CLEAN AND AS N. LAMPS SHALL BE NEW AT PROJECT COMPLETION. 7. INSTALL THE SUSPENDED CEILING ACCORDING TO TI-IE RECOMMENDATIONS OF THE CEILING SYSTEM MANUFACTURER. 8. CONTRACTOR SHALL PROVIDE ALL LATERAL BRACING, COMPRESSION STRUTS AND HOLD -DOWN CLIPS, AS REQUIRED BY THE GOVERNING JURISDICTION, FOR ALL SUSPENDED CEILING AND SOFFIT FRAMING CONDITIONS. q. VERIFY ABILITY OF EXISTING STRUCTURE ABOVE TO SUPPORT THE NEW SUSPENDED CEILING 5YsTEM AND INCLUDED EQUIPMENT. 10. IN5TALL ADDITIONAL BACKING PLATES/BLOCKING AND SUSPENSION WIRES AT ALL EQUIPMENT ATTACHED DIRECTLY TO THE NEW SUSPENDED CEILING SYSTEM AND NOT INDIVIDUALLY SUPPORTED OTHERWISE. 1 GENERAL NOTES 1 1. NO WORK DEFECTIVE IN WORKMANSHIP OR QUALITY OR DEFICIENT IN ANY REQUIREMENTS OF THE CONTRACT DOCUMENTS WILL BE ACCEPTABLE DESPITE T14E ARCHITECT'S/TENANT'S FAILURE TO DISCOVER OR POINT OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION. DEFECTIVE WORK REVEALED OR POINT OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION. DEFECTIVE WORK REVEALED WITHIN THE TIME REQUIRED BY GUARANTEE SHALL BE REPLACED BY WORK CONFORMING TO THE INTENT OF THE CONTRACT. NO PAYMENT, EITHER PARTIAL OR FINAL, SHALL 8E CONSTRUED AS AN ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS. 2. SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE FOR WHATEVER REASON UNENFORCEABLE, SUCH UNENFORCEABILITr SHALL NOT EXTEND TO THE REMAINDER OF THE CONTRACT NOR 5I-ALL IT VOID ANY OTHER PROVISIONS of THE CONTRACT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER HIS JURISDICTION. 4. DO NOT PROCEED WITH ANY WORK REQUIRING ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM THE TENANT, FAILURE TO OBTAIN AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION_ 5. ALL INSTALLED PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL OPERATE QUIETLY AND FREE OF VIBRATION. 6. UPON NOTIFICATION OF COMPLETION OF THE WORK AND DELIVERY OF T E CONTRACTOR'S PUNCH -LIST THE TENANT SHALL PREPARE A PUNCH -LIST OF CORRECTIONS, UNSATISFACTORY AND /OR INCOMPLETE WORK. FINAL PAYMENT WILL BE CONTINGENT UPON THE COMPLETION OF THESE ITEMS UNDER THE TERMS OF THE OWNER/CONTRACTOR AGREEMENT. 7. ALL MATERIALS SHALL BE NEW, UNUSED, AND OF 114E 141G14E5T QUALITY IN EVERY RESPECT UNLESS OTHERWISE NOTED, MANUFACTURED MATERIALS AND EQUIPMENT SHALL SE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS U.O.N. 5. COORDINATE ALL'WORK WITH BUILDING OWNER 50 AS NOT TO DISTURB OR CAUSE DAMAGE TO ANY TENANT IN THE BUILDING. AVOID CONFLICT AND INTERFERENCE WITH NORMAL BUILDING OPERATIONS BY COMPLYING WITH THE BUILDING'S REGULATIONS REGARDING SCHEDULING AND USE OF ELEVATORS AND LOADING DOCKS FOR DELIVERIES, HANDLING OF MATERIALS, EQUIPMENT, AND DEBRIS. PROVIDE PROTECTION TO ALL EXISTING FINISHES IN ALL SPACES WITHIN OR ADJACENT TO THE SCOPE OR WORK AND THE TENANT'S SPACE. THE CONTRACTOR 51-IALL PATCH AND REPAIR ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS. REFINISH TO MATCH EXISTING ADJACENT FINISH, OR A5 NOTED HEREIN. 10. ALL ON -SITE MATERIAL STORAGE SHALL BE INSIDE THE DEMISED PREMISES. 11. CORRECT ANY DEFECTS FOUND IN EXISTING BUILDING CONSTRUCTION WHICH AFFECT 114E SCOPE OF WORK THIS INCLUDES BUT IS NOT LIMITED TO UNEVEN SURFACES AND FINISHES AT DRYWALL OR DAMAGED FIREPROOFING. PATCH AND REPAIR SURFACES 70 MATCH ADJACENT, ADJOINING SURFACES. 12. THE ARCHITECT/TENANT HAS NO KNOWLEDGE OF AND SHALL NOT BE HELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDOUS MATERIALS ON THE JOB SITE IF ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE DISCOVERED DURING CONSTRUCTION OR DEMOLITION, STOP WORK AND CONTACT TENANT FOR FURTHER INSTRUCTIONS BEFORE PROCEEDING. 13. ALL REQUIRED EXITS SHALL BE OPERABLE FROM INSIDE, WITHOUT THE USE OF KEY OR SPECIAL KNOWLEDGE. 14. EXIT DOORS AT STOREFRONT TO HAVE SIGN ON TOP RAIL STATING "T1 -ITS DOOR TO REMAIN UNLOCKED DURING BUSINESS 140UR5' IN 1" HIGH WHITE LETTERS ON A TRANSPARENT BACKGROUND. LOCKING DEVICE TO BE OF THE TYPE THAT I5 READILY DISTINGUISHABLE AS LOCKED. 1 GENERAL NOTES (CONT) I 15. ALL ROOF DECK PENETRATIONS AND EXTERIOR WALL OPENINGS SHALL SE GUARANTEED BY THE CONTRACTOR TO BE WATERTIGHT FOR A MINIMUM PERIOD OF ONE YEAR AFTER SUBSTANTIAL COMPLETION OF ALL WORK UNDER 71415 CONTRACT. 16. SEALANT, CAULKING AND FLASHING, ETC. LOCATIONS SHOWN ON DRAWINGS ARE NOT INTENDED TO E5E INCLUSIVE. FOLLOW MANUFACTURER'S INSTALLATION RECOMMENDATIONS AND STANDARD INDUSTRY AND BUILDING PRACTICES. 17. ALL CONCEALED SPACES CREATED BY FURRING BE141ND BUILT -IN CASE WORK AND PANELING 514ALL HAVE FIRE BLOCKING (MINERAL FIBER OR APPROVED ALTERNATE) SO THAT NO VOID EXCEEDS 10' VERTICALLY OR HORIZONTALLY. 18. FIRE BLOCKING SHALL BE INSTALLED IN CONCEALED SPACES FORMED BY FLOOR SLEEPERS IN AREAS OF NOT MORE THAN 100 SQUARE FEET. Iq. ALL BUILT -IN CASES AND PANELING SHALL MEET A MINIMUM CLASS III FLAME SPREAD (76 -200 FLAME SPREAD INDEX). PLYWOOD SHALL BE STAMPED WITH UL LABEL. 20. CONTRACTOR SHALL LEAVE PREMISES AND ALL AFFECTED AREAS CLEAN AND \ORDERLY, READY FOR OCCUPANCY. THIS INCLUDES CLEANING OF ALL GLASS (INSIDE AND OUTSIDE) AND FRAMES, BOTH NEW AND EXISTING. 21. ALL WORK SHALL SE PERFORMED IN A PROFESSIONAL, WORKMANLIKE MANNER AND SHALL CONFORM TO ALL STATE, FEDERAL, AND LOCAL CODES. INDUSTRY ORGANIZATION STANDARDS, OR AS REQUIRED 1BY LANDLORD. OTHERWISE CONTRACTOR WILL BE HELD LIABLE TO CORRECT ANY MISTAKES NOT COMPLYING TO THESE CODES AND ORGANIZATIONS AS MENTIONED. 22. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. ONE COMPLETE COPY OF THE CURRENT SPECIFICATIONS AND ALL ADDENDA MUST BE KEPT AT 714E JOB AT ALL TIMES- NO EXTRAS OR EXTENSIONS WILL BE GRANTED FOR FAILURE TO FOLLOW THE SPECS. 23. AS A GENERAL RULE, DIMENSIONS ARE TAKEN FROM MAJOR SURFACES OR PANEL SURFACES, NOT FROM THE PROJECTIONS OF MOLDINGS APPLIED TO THE SURFACE OR EDGE. MOLDING PROJECTIONS VARY, BUT MOST ARE 1/4 TO 3/8 BEYOND WE FACE. 24. ALL BLOCKING ABOVE CEILING OR IN PARTITIONS SHALL BE 'NONCOMBUSTIBLE' APPLY 'FLAMORT'FIRE RETARDANT COATINGS WHERE NECESSARY TO MEET CODES OR LANDLORD REQUIREMENTS - SEE SPECIFICATIONS. 25. THIS CONTRACTOR SHALL MAINTAIN ALL FIRE RATINGS AS REQUIRED BY CODES. BY THE LANDLORD AN HIS FIRE UNDERWRITER. 26. STRUCTURAL FRAMING MEMBERS FOR THE STOREFRONT AND INTERIOR AREAS SHALL 8E LOAD BEARING STUDS. THIS CONTRACTOR SHALL COORDINATE WITH THE LANDLORD ON LOCATIONS, WEIGHT, AND METHOD OF ATTACHMENT OF ALL LOADS IMPOSED DN THE OVERHEAD STRUCTURE. ANY FIREPROOFING THAT IS DISTURBED 514ALL BE RESTORED TO ITS ORIGINAL CONDITION. 27. ALL NAIL, SCREW, AND FASTENER HOLES SHALL BE FILLED AND SANDED SMOOTH, READY FOR PAINTING JOINTS IN MATERIAL SHALL BE KEPT TO A MINIMUM AND SHALL BE AT CORNERS WHEN POSSIBLE JOINTS IN EXPOSED FACES SHALL HE TIGHT AND FLUSH JOINTS SHOULD BE PLANNED TO FALL BEHIND MOLDING. ALL. EXPOSED JOINTS SHALL BE FILLED AND SANDED. 28. ALL OUTSIDE CORNERS WHICH ARE VISIBLE AND ARE NOT COVERED BY MOLDINGS. SHALL BE MITERED, TRUE AND TIGHT, EXPOSED EDGES OF PLYWOOD SHALL NOT 8E PERMITTED. 2q. TENANT SHALL FURNISH AND THIS CONTRACTOR SI4ALL INSTALL HARDWOOD FLOORING THROUGHOUT 714E SALES AREA AND FITTING ROOMS AS INDICATED ON THE DRAWINGS. 5EE SPECS. 30. THIS CONTRACTOR SHALL COORDINATE ALL WORK ON THE SIGN AND SIGN LIGHTING WITH E.G. AND TENANT. 714E SIGN WILL BE FURNISHED BY TENANT, SAFE HANDLING, STORAGE AND INSTALLATION SHALL SE THE RESPON5I8ILITY OF THE G.C. REPAIR OF ANY DAMAGE TO THE SIGN. WILL BE UNDER THE DIRECTION OF TENANT AT THE G.C.'S EXPENSE. 31. THE G.C. SHALL COORDINATE THE PAINTING OF 114E LIGHTING FIXTURES AND OTHER SPECIAL EQUIPMENT DETAILED IN THE FINISH SCHEDULE SEE ALL SPECS. 32. T1-1I5 CONTRACTOR 514ALL COORDINATE WITH THE LANDLORD (AND OTHERS .AS REQ'D.) FOR THE ERECTION OF BARRICADES, MOVEMENT OF MATERIALS, TRASH REMOVAL. 33. TENANT SHALL FURNISH WOOD FLOORING, SIGN, LIGHT FIXTURES, DECALS, DETEX ALARM, SLOTTED STANDARD IN METAL STUD ASSEMBLY AND MILLWORK PACKAGE ALL OF WHICH ARE TO BE INSTALLED BY THE CONTRACTOR. 34. THIS CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR ALL FINISHED FLOORS DURING CONSTRUCTION, IN PARTICULAR ALL FLOORS SHALL BE PROTECTED AS FOLLOWS PRIOR TO THE ARRIVAL OF STORE FIXTURES, WOOD FLOORS SI4ALL BE COVERED COMPLETELY WITH 70 LB. KRAFT PAPER. CARPET 514ALL BE COVERED WITH 4 MIL VISQUEEN CERAMIC TILE SHALL SE COVERED WITH 1/4 PLYWOOD. 35. TENANT SHALL FURNISH, PRIOR TO OPENING, ABC TYPE FIRE EXTINGUISHERS OF SIZE REQUIRED BY LOCAL CODES. 36. IF APPLICABLE, THE GENERAL CONTRACTOR SHALL COORDINATE WITH T14E MECHANICAL CONTRACTOR AND THE LANDLORD THE LOCATION AND SIZE OF RETURN AIR OPENINGS IN THE DEMISING WALLS ABOVE THE CEILING T1415 CONTRACTOR SHALL PROVIDE A REAMING SECURITY SCREEN OVER THESE OPENINGS OF I ° x1 ° WIRE MESH. 37. - 1-IE GENERAL. CONTRACTOR SHALL FIELD MEASURE THE LEASED PREMISES AND PROVIDE TENANT A DRAWING WITH ACCURATE ACTUAL DIMENSIONS, PARTICULARLY VERIFY DIMENSIONS IN THE AREA OF THE STOREFRONT. NOTIFY TENANT OF ANY DISCREPANCIES AND PROBLEMS THAT MAY OCCUR IMMEDIATELY. 38. THIS CONTRACTOR SHALL PROVIDE EXPANSION JOINTS IN THE HARDWOOD FLOOR STOREFRONT, WALLS ETC. AS SHOWN OR REQUIRED EXPANSION JOINT IN HARDWOOD FLOOR SHALL BE THE RUBBER OR NEOPRENE TYPE, SET FLUSH WITH THE HARDWOOD FLOOR IN EITHER SIDE. 3q. FURRING CHANNELS SHALL BE GALVANIZED, METAL STUDS SHALL BE 20 GAUGE MIN. GALVANIZED STEEL WITH MATCHING TRACKS IN WIDTHS AS SHOWN ON THESE DRAWINGS. USE MINIMUM 20 GAUGE (OR AS INDICATED) LOAD BEARING METAL STUDS WHERE INDICATED. METAL 'C' JOISTS SHALL BE 14 GAUGE WITH APPROPRIATE CONNECTORS AND FASTENERS. WELD CONNECTIONS AS INDICATED OR REQUIRED 40. IF EXISTING G.C. SHALL REPAIR ANY FIRE PROOFING ON EXISTING STRUCTURAL STEEL MEMBERS 1.414E11-1ER IT 5E SPRAT -ON OR OTHER. 41. PRIOR TO BID SUBMISSION AND COMMENCEMENT OP WORK, THE G.C. SHALL MAKE A SITE VISIT TO THE EXISTING SPACE TO REVIEW DEMOLITION /SALVAGE REQUIREMENTS. COORDINATE ALL DEMOLITION WITH TENANT'S MANAGER OF CONSTRUCTION AND LANDLORD'S FIELD REPRESENTATIVE. 42. NOTHING SHALL BE ATTACHED TO OR SUSPENDED FROM ROOF DECK ABOVE. IF REQUIRED BY LANDLORD OR BUILDING DEPARMENT, G.C. SHALL BRACE/SECURE FROM TOP CHORD OF .JOIST OR STRUCTURAL STEEL ONLY. DEFINITIONS TENANT - AMERICAN EAGLE OUTFITTERS G.C. - GENERAL CONTRACTOR LANDLORD - MALL'S LANDLORD Pot-o6 Si.ned ° Date O E CO LIAR < 1 7° -i____ il C��Y DIVISION ILDxxG RECEIVED CITY OF TUKWILA FEB B 4 2003 PERMIT CENTER WslIle[L[ Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant Is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir lobe kept on the job sit 12/28/07 NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY WAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. it r/T C► 0 e1 Cn 4).dri &au' ems 1 n LU CD 1 Z ILI IL LL.0 �.J CZ Drawn v,• 2751 •" a In 0 � 4 ca 0 S ' - 3 _v (0 1- r Approved Drawing NO. (4 e4 L MATERIAL KEY PROFILE TYPE DF5CRIPTION, LOCATION it PREDOMINANT USE WALL CEILING [Wn -ia] TRIM (ENTIRE STORE) - SIZES 4 CONFIGURATIONS VARY am DOORS ---)</—■ SALES AREA (101a) [FC -1a] [FC -2a] CP -203 [P -4a] VARI EP-4a3 ole [P-1a3 FREFINISHED [8 -la] CB -tai CWD -2a] WALL PANEL - ENTIRE STORE DISPLAY CASES AS INDICATED. [P -20] CP -4a3 [P-3a3 NONE NONE [P -1a] [P -la] [15-1a] C•-2a3 4 " [FC -1a3 0,,o_303 C-3a] WALL PANEL - STOREFRONT COLUMNS, FASCIA, # DISPLAY PLATFORMS AS INDICATED. NONE NONE LP -10 CP -1a3 CB- lal03 -2a] FITTING was (104a) CFC -1a] [FC -6a] • • • • • . • - (P -3a] NONE NONE [P -10] CP -Ia] 211 STOCKROOM (105a) CWD -4a] INDIVIDUAL PLANKS - STOREFRONT SOFFITS 4 FITTING ROOM CEILINGS ONLY {FIELD APPLIED). ewo NONE NONE NONE [P-1a3 03-303 TOILET ROOM (106a) - :Ij I.a�,�IK�� :rig -r::+ TEilla 1/- - �, �r.'' NONE D CP -Ia] [P -la] C5-301 EXIT CORRIDOR (107a) [FC -4a] 6 r NONE [WD -64] RESAWN CEILING PLANKS - SALES AREA CEILING AS INDICATED NONE EP-1a3 [13-3a] COMPUTERRObM (1052) _ orm PRIME ONLY NONE NONE NONE NONE 111 3" y y C13R -la] INDIVIDUAL BRICK PIECES APPLIED TO DRYWALL SURFACE WITH r MORTAR GAPS. SHALL WI-41TE SAND GROUT LG NOTE: .�....���\�... --.'. MORTAR TO BE BAC APPLIED AND SHALL BE "THUMB" STRUCK TO OBTAIN IRRECULARJOINP CONSISTENCY. COORDINATE Will TENANT FIELD REP. (STOREFRONT E RICK APPLICATION) u 6 CFC -703 PLANKS - D PLAY PLATFORM " ; FINISH SC-I E D U L E 1. REFER TO FLOOR COVERING SCHEDULE, PAINT SCHEDULE, STAIN SCHEDULE AND BASE SCHEDULE THIS SHEET 2. COORDINATE FINISH SCHEDULE WITH ARCHITECTURAL DRAWINGS FOR GRAPHIC CLARIFICATION ROOM FLOOR WALL CEILING ROOM DIVIDERS /ARCHES CEILING BEAMS TRIM DOORS WALL BASE SALES AREA (101a) [FC -1a] [FC -2a] CP -203 [P -4a] CP -3a] EP-4a3 CP -440 [P-1a3 FREFINISHED [8 -la] CB -tai PASSAGE (102a) CFC -10 CFC -6a] [P -20] CP -4a3 [P-3a3 NONE NONE [P -1a] [P -la] [15-1a] C•-2a3 VESTIBULE (103a) [FC -1a3 CP -4a] EP-4a3 NONE NONE LP -10 CP -1a3 CB- lal03 -2a] FITTING was (104a) CFC -1a] [FC -6a] [P -2a] CP-443 (P -3a] NONE NONE [P -10] CP -Ia] CS -1a3 CB -2a3 STOCKROOM (105a) [FC -4a] PRIME ONLY NONE NONE NONE NONE [P-1a3 03-303 TOILET ROOM (106a) [FC -3a] DRYWALL EP-2a3 (P -3a] NONE NONE CP -Ia] [P -la] C5-301 EXIT CORRIDOR (107a) [FC -4a] PRIME ONLY NONE PRIME ONLY NONE NONE EP-1a3 [13-3a] COMPUTERRObM (1052) [FC -4a] PRIME ONLY NONE NONE NONE NONE [P -la] C13-3a3 PAIN' SC - IFIDDLE [F-la] (2) COATS SW PROMAR 200 INTERIOR LATEX SEMI GLOSS (133114207) 514#7104 'COTTON WHITE' OVER (I) COAT SW PREFRITE CLASSIC INTERIOR LATEX PRIMER (132814200) SPRAY APPLIED IN THE FIELD (AERIE - WOOD, TRIM AND DOOR APPLICATIONS) CP -29] (2) COATS S14 PROMAR 200 INTERIOR LATEX SEMI - GLOSS (83114207) 5W#7104 'COTTON WHITE' OVER (1) COAT SW PREPRITE CLASSIC INTERIOR LATEX PRIMER (B28V1Z00) (SPRAYED THEN BACK ROLLED) (AERIE - DRYWALL 0 VESTIBULE $ COLUMNS, IF APPLICABLE) [P -30 (2) COATS SW PROMAR 200 INTERIOR LATEX EGGSHELL (62414207) COMPOSED OP 50% 'PURE 14HITE' AND 50Z swim 'car70N WHITE' OVER (1) COAT 514 PREPRITE CLASSIC INTERIOR LATEX PRIMER (82814200) (AERIE - BEAMS, DRYWALL * WOOD CEILINGS) no-4a] (2) COATS SW PROMAR 200 INTERIOR LATEX 5E11 (831141201) 5141#II23 'NAVAJO WHITE' OVER 1 COAT SW PREPRITE CLASSIC INTERIOR LATEX PRIMER (132814101) - (SPRAYED THEN BACK ROLLED) (AERIE - ROOM DIVIDERS, ARCHES, UPPER DRYWALL) EP-5a3 (2) COATS SW PROMAR 200 INTERIOR LATEX EGGSHELL (62014207) COATING 'AERIE BLUE" SEE COLOR SPECS BELOW (SPRAYED THEN ROLLED) SHERWIN WILLIAMS COLOR FORMULA SPECS (GALLON FORMULA) SAC COLORANT OZ 32 64 128 1-1 -15LUE 2 47 I - R2- MAROON - 5 1 - R3- MAGENTA 2 10 1 1 (AERIE - CASH /WRAP WALL) [P -6a] (2) COATS SW ARMORSEAL TREAD -FLEX ACRYLIC FLOOR COATING (6c1O14101) 54t7104 'COTTow WHITE: OVER (I) COAT SW TREAD -FLEX PRIMER (69014110) (BRUSH APPLIED IN FIELD) (AERIE - DISPLAY WINDOW FLOOR) CP -7a] 2 C S OATS 4 ARMORSEAL TREAD -PLO! ACRYLIC FLOOR COATING (890144101) 514 #1005 SILVERADC OVER 1 COAT SW TREAD - FLEX PRIMER (B901410) (STOCKROOM FLOOR) 1. ACCESS DOORS ARE TO BE FIELD PAINTED TO MATCH ADJACENT SURFACES PRIOR TO INSTALLATION. 2- PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM 4 WALL PRIOR TO PAINTING. / HOOD SCHEDULE 1:104D-103 PAINTED, STOCK *2 COMMON PAINT GRADE YELLOW POPLAR AT WOOD DESIGNATED TO BE PAINTED, TIGHT KNOTS AND CHECKING DESIRABLE, SURFACED 2 SIDES, UNSANDED. CWD -20] 5/8 'ARCHITECTURAL GRADE" (WOOD VENEERED) MEDIUM DENSITY FIBERBOARD (MDF) PREPRIMED WITH PREMACHINED 'BEADEOARD" LOOK (BY MILLWORK SUPPLIER). (FIELD CUT AS REQUIRED) CWD -30] 5/8" 'ARCHITECTURAL GRADE' (WOOD VENEERED) MEDIUM DENSITY FIBERBOARD (MDF) PREPRIMED. REROUTED 1/8" X IN SLOTS AT A O.C. CWD -4a] S/8' "THICK BEADBDARD PLANKS, SOLID STOCK *2 COMMON PAINT GRADE YELLOW POPLAR TIGHT KNOTS AND CHECKING DESIRABLE. ;ii. h.•, •y} it sP � �� I.' 111, P ..T C1.4n -6a] 3/8' RESAWN CEILING PLANKS, BUTT JOINT EDGES, LOOSE FITTING. (CEILING APPLICATION ONLY) [WD -7a] 9116' POPLAR TONGUE 4 GROOVE PLANKS. (DISPLAY PLATFORM) .µ1a`_; • IV . ;N ` , tie " 1 C + ..ry 5 F .4 KI••.VYi APL ::1al:;LKlh MI SL' i w Y or) . 4 N °' f n, i;�.T f:. � `T: 3, $15.A )t° LIAI)-12ct,1 3/3" I I•IIC,K a-4tPLAP c CHE."KING V .SIFO,Blh 1 1I -Pc°KN s=: ) CLASS C OR III L C r ! ' R :J�: 114,11 I KIWI ;": :. AND .,s 1r ' "'`1r; 61 ( N I 1E, • ::t r..; '' ` :1 : 104 71,40_12,n] Ste MICK I3� L . r Li ST .,. /IND CII 'C4C!N DES! ABI • :It:, AI?., t : (.Yr 7. F, i i 71 Cr �,.No rs 130 NOTE: SEE WOOD MATERIAL KEY THIS SHEET NOTE: SEE FLAME SPREAD CLASSIFICATIONS THIS SHEET FLOOR COVERING SCI -I EDU LE LIK 3/4" X 6' TONGUE AND GROOVE PREFINISHED OAK FLOORING ON 3/4" PLYWOOD SUBFLOOR- FREFINISHED WOOD FLOOR AND PLYWOOD FURNISHED BY TENANT, INSTALLED BY G.C. SEE SPECIFICATIONS FOR INSTALLATION INSTRUCTIONS. [1 Ia] 'RANDOM' CONCRETE PAVERS FURNISHED BY TENANT, INST. BY G.G. (SEE DRAWINGS FOR APPLICATION 4 PATTERN). SANDED FLOOR GROUT SHALL BE FURNISHED BY TENANT $ INST. BY G.C.. NOT : GROUT MINIS SHALL Mir WIDE. IfC -311 COMMERCIAL GRADE SHEET VINYL 'WHITE" OVER WATERPROOF MEMBRANI FURNISHED AND INSTALLED BY G.C. ITC-431 EXPOSED CONCRETE/PLYWOOD - PAINT [P-7a3 ;ii. h.•, I..' ". . ,..tl t . 1 • F '/ a.', RI -r i Xi ° Aft MANI F 5- -zURED B1 1 sa' r !C• rvt t f ,d: rug' 51-1• At II *TA LEI. BY :.x. , !x.40 CARPET- FUR` a ED Vol" , ` T ED BY G.C. MANUFACTURER: ALADDIN BY MOHAWK STYLE: 8800 NEWPORT ROSE COLOR: 726 CAMEO MIST PILE: IDOX SOLUTIA WEAR -DATED II NYLON ITC-76] 9/16' POPLAR TONGUE # GROOVE PLANKS, (DISPLAY PLATFORM ONLY) 1, 2. FLOOR COVERING NOTES: SEE SHEET 'A.0.1' FOR FLOORING LAYOUT REFER TO FLOOR TRANSITION DETAILS FOR TRANSITION STRIP SPECIFICATIONS. NOTE: SEE FLAME SPREAD CLASSIFICATIONS THIS SHEET FLAME SPREAD CLASSIFICATIONS MATERIAL DESCRIPTION CLASSIFICATION FLAME SPREAD RATING CWD -10] (YELLOW POPLAR) CLASS C OR III 130 CWD -2a] (MDF) CLASS C OR 111 120 CWD -30] (YELLOW POPLAR) CLASS C OR III 130 CWD -4a] (YELLOW POPLAR) CLASS C OR III 130 r1P4o- 43 (O AR) DELETE c .R 111 120 END-6a] (CEDAR) CLASS C OR III 120 [FC -Ia] (MAPLE) CLASS C OR III 104 CFC -6423 (CARPET) PILL TEST - 16CFR- 1630.4 (FF -1 -70) : PASS cm-7a] (POPLAR) CLASS C OR III 130 PLYWOOD AT PLATFORM CLASS A OR I 25 , SASE SCHEDULE CB -1a] 3/4'x 5 1/2" SOLID STOCK *2 COMMON POPLAR W/ CHAMFERED EDGE. SEE DETAIL E/A -8 FOR PROFILE. FURNISHED BY TENANT, INSTALLED BY G.C. CB -2a] 3/4' x 1 1/4" SOLID STOCK #2: COMMON POPLAR SASE SHOE. SEE DETAIL E/A -B FOR PROFILE. FURNISHED BY TENANT, INSTALLED BY G.C. CB -3a] 4' HIGH BLACK VINYL COVE BASE FURNISHED AND INSTALLED BY G.G. [I3 [FC -2a] gx9 TILE C `! T ^ CUT INSTALLED : � I i!I i 1F4;.a . ; 'TENANT, , � MOM MAIO AfAr inta METAL SCHEDULE cl i•..lcl WOT -ROL' ELLE POWDER COAT FINISH; [M -2] 3/4' x 3/4' ALUMINUM REVEAL BLACK FINISH - FURNISHED AND INSTALLED BY G.C. (BLIND FASTENED) t? ALUMINUM D 'EjEPC ,. r FINIS', NOTE: THE USE OF CONTRACTORS SHALL HE DICTATED BY THE TERMS AND CONDITIONS OF THE LEASE _ AGREEMENT. 6 METAL STUD 1- LEADER BY G.G. 11 1 BARRICADE - FURN. * INST. BY TENANT G.C. CP -10] 4' -O" TENANT BARRICADE DETAIL (INTERIOR VIEW) OF REMOVABLE PANEL # FUTURE ENTRY (SEE ARCM. DWGS.) TENANT LOGO GRAPHIC (WHITE LETTERS ON 'AERIE BLUE" BACKGROUND) - FURN. rk INST. BY OTHERS REMOVABLE FLUSH PANEL (P -Ia) WHERE OCCURS. SEE DETAILS S /C.S.2.3 * C /C5.2.3 FOR MORE INFO. STOREFRONT WIDTH (LEASE LINE TO LEASE LINE) A TENANT ARICADE DETAIL (EXTEO VIEW) C9,2.3 SCALE : 1/2 = 31' METAL STUDS, 24' O.G. BY G.C. PULL HANDLE BY G.C. (TYP OF 2) SLIDE BOLT BY G.C. TYP OF (B) REMOVABLE FLUSH PANEL FURN 4 INST. BY G.C. 3 5/$" METAL STUDS 24 O.G. BY G.C. 5/8" GYP. BD. (P -10) BY G.C. FINISI4ED FLOOR LINE 'J' MOLDING AT PERIMETER BY G.C. C 05.2.3 SCALE : 3 ".1' -O" STOREFRONT BARRICADE NOTES: 1. G.G. IS TO CONSTRUCT TEMPORARY BARRICADE(S) OF 3 5/6" 25 GA. METAL STUDS AT 24" O.C. WITH ONE LAYER 5 /B" GYP. BD. (MALL SIDE) TAPED AND SPACKLED SMOOTH. INSTALL A 4 MIL. PLASTIC OR GYP. 8D. LID BACK TO MALL BULKHEAD TO CREATE DUST -PROOF CONDITION AND INSTALL 1/2" C -D PLYWOOD ON FLOOR TO PROTECT EXISTING MALL FLOORING. SUBSTITUTE GYP. BD. AND PLASTIC WITH 5 /5" EXTERIOR GRADE PLYWOOD, FULL HEIGHT, AT EXTERIOR STOREFRONTS. BARRICADES ARE TO BE ADEQUATELY SECURED AND BRACED TO MALL BULKHEAD FRAMING FOR LATERAL STABILITY AND MUST BE STRUCTURALLY SOUND. CARE MUST BE TAKEN TO PROTECT MALL FLOORING. SEE 'TENANT BARRICADE DETAIL' ON THIS SHEET FOR MORE INFORMATION. 2. CARE IS TO BE TAKEN WHEN DISASSEMBLING AND REMOVING BARRICADE. G.C. IS TO RESTORE MALL SOFFIT, FASCIA, NEUTRAL PIERS AND FLOOR TO A 'LIKE -NEW' CONDITION AND FINISH. 3. G.C. IS TO CONSULT WITH MALL REPRESENTATIVE FOR HOURS IN WHICH WORK ON BARRICADE CAN OCCUR. TENANT SEASONAL GRAPHICS - FURN. INST. BY OTHERS (TYP) MAX (MALL SIDE' SLIDE BOLT TYP (4) EACH SIDE BY G.C. 2x4 NON COM NAILERS BY G.G. (FASTEN AS INDICATED) REMOVABLE FLUSH PANEL - 1/4" MASONITE OVER 3/B' PLYWOOD BY G.G. (P -1a) REMOVABLE FLUSH PANEL 905-05 po RECEIVED CITY TUf FEB 0 4 2008 PERMIT CENTER WstIle[t[ Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect andfor Contractor Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped at of drawings Is requir- • to be kept on the Job site at a 1 SI•ned Date PARTITION INDEX TYPE PRII"IARY DESCRIPTION STUDS DRYWALL SURFACE PREPARATION }REMARKS 0 NEW DEMISING PARTITION 3 5/8" METAL 16" O,C•, TO STRUCTURE, BY L,L. 5/8" DRYWALL TENANT SIDE TO STRUCTURE AND SEAL (I) HR RATED BY G.G. TAPE, SPACKLE, SAND AND PRIME BY G.C. U.L. DESIGN #U465 -SEE DETAILS ON THIS SHEET 40" STOCKROOM PARTITION 3 5/8" METAL 16" D • C TO STRUCTURE, BY G.C. 5/8" DRYWALL (SALES SIDE TO 6" ABOVE CEILING, (STOCK SIDE) TO UNDERSIDE OF PECK BY G,C, (SEE REMARKS) TAPE SPACKLE SAND AND PRIME BY G,C, D.14., BOTH SIDES, TO STRUCTURE ABOVE AND SEAL (1) HOUR RATED, IF REQ'D. BY L.L. OR B.D. U.L. DESIGN #U465 -SEE DETAILS ON THIS SHEET le SALES AREA FURRED -OUT PARTITION 15/8" METAL 8 METAL INSERT ADAPTOR W/ INTEGRAL SLOTTED STANDARD NONE NONE SEE DETAIL D/A.2,7 BRACE NALL BACK TO DEMISING NALL 5 A.F.F. (4' -0" Q.C. MIN.) . SALES AREA PARTITION 3 5/8' METAL B METAL INSERT ADAPTOR W/ INTEGRAL SLOTTED STANDARD 5/5" TYPE 'X', NON -SALES SIDE TO UNDERSIDE OF CEILING, BY C.C. . TAPE, SPACKLE, SAND AND PRIME BY G.C. SEE DETAIL E/A.2.7 SALES AREA PARTITION 2 1/2" METAL is" D.C. TO CEILING, BY G.C. 5/8" TYPE 'X', FINISHED SIDE TO UNDERSIDE OF CEILING, BY G.C. TAPE, SPACKLE, SAND AND PRIME BY G.C. 4 TOILET ROOM PARTITION 3 5/8' METAL 24' O.C. TO CEILING, 67 G.C. 5/8' GREENBOARD, T. RM. SIDE - 5/8" TYPE 'X', STOCK SIDE TO CEILING BY G.G. TAPE, SPACKLE, SAND AND PRIME BY G.C. 410 TOILET ROOM P ARTITION 6' METAL 24' O.C,, TO CEILING, BY G.C. 5/5" GREENBOARp T. RM, SIDE - 5/8' TYPE 'X', STOCK SIDE (WHERE REQUIRED) 70 CEILING BY G.C. PRIME BY G SPACKLE SAND AND 10 EXIT CORRIDOR PARTITION 3 5/8" METAL 24" O.G., 10' -0" A.F.F., BY G,C. 5/8" DRYWALL, BOTH SIDES TO 10' -0" A.F,F,, BY G.C. TAPE, SPACKLE SAND AND PRIME BY G.C. . WING WALL PARTITION 3 5 /S' METAL $ METAL INSERT ADAPTOR W/ INTEGRAL SLOTTED STANDARD(BOTH SIDES) NONE NONE PASSAGE (102a) SEE FINISH SCWIEDULE ON SWEET 'C5.2.3' AND ELEVATIONS ON SHEET 'A.2.6' RI"I. #3 \J RAC 1:20 SALES AREA (101a) SEE FINISH SCHEDULE ON SWEET 'CS.2.3' AND ELEVATIONS ON SHEET 'A.2.6' CASH $ WRAP - FURN. BY TENANT, INST. BY G.G. - SEE SWEET 'F.2.2' $ 'F.2 -2a' FOR DETAILS. ` &2,7a) DIRECTION OF WOOD ' FLOORING BRICK COLUMN SEE DET. AA/A.2.8 RAISED DISPLAY PLATFORM. SEE SHEET 'A,2.5' FOR DETAIL (TYP). '\`,.\"; N - \(; \ /•\ I L CONCEALED SLOTTED / \<' '<'` 'N <'\'<\ ' ' I STANDARDS SEE DETAIt•,-'\r'y''ti y \ Aq G /A.2.7 (TYP.) x '\ , ' ` � ; <''' "'‘,/^'',/ `\ - - - -- - \-1 Y Y y Y S' \ v \ \ y / / 'VESTIBULE (103a) SEE FINISH SCHEDULE ON SHEET 'CS.2.3' AND ELEVATIONS ON SHEET 'A.2.6 107' -0.4 'IXII BRACING LEASE LINE City 01 Tukwila BUILD1N( M WALLS G.C. SHALL FINISH DEMISING IN FITTING ROOMS TO 'LIKE NEW' CONDITION TO MATCI-1 ADJACENT SURFACES. W'NOTE: SEE SWEET 'F.0,1' FOR LOCATIONS OF FITTING ROOT BENCHES, MIRROR'S, COATIOOKS, ETC. FLUSH INLAID CARPET WITH WOOD FLOOR BORDER. (TYP IN EACH FITTING ROOM AND IN VESTIBULE) CORRDINATE ANGLE WITH PREFAB. WALL. SEE SWEET 'F.O.1' (TYP) Ana iO Lilco ssi FITTING ROOMS (104a) (TYP.) SEE FINISH SCHEDULE ON SHEET 'CS,2,3' AND ELEVATIONS ON SWEET 'A.2.q' 1wIC. TOI LET ROOM (1060 SEE FINISH SCHEDULE ON SWEET 1 C9.2 AND DETAILS A/A.0.1a, B /A,0.1a, C /A.O.Ia $ /A.O.la r° ulrn LOIco rn tO I 64, BENCHMARK NO. 7 FACE OF STRUCT. COLUMN 10' -0 STOCKROOM (105a) SEE FINISH SCHEDULE ON SHEET 'CS.2.3' SEE SHEET 'F.0.1' FOR SHELVING LAYOUT a TRANSFORMER TO BE MOUNTED OVERHEAD @ 8' -O" A.F.F. TO BOTTOM LOI 36" GRAB BAR (TYP.) 42" GRAB BAR (TYP.) ire on V DRINKING FOUNTAIN EXIT CORRIDOR (107a) \ SEE FINISH SCHEDULE ON SHEET 'CS.2.3' AND DETAIL D /A.O.la ELECTRICAL PANELS 23 BENCHMARK NO. 6 BENCHMARK NO. 5 NEW RAMP AND PLATFORM 5/5" NONCOMBUSTIBLE PLYWOOD OVER SLEEPERS AS REQ'D. BY G.C. G.C. SHALL FURN. AND INST. ALUMINUM THRESHOLD AT BOTTOM EDGE OF RAMP STORE LAYOUT NOTE: • G.C. SHALL FIRST VERIFY PERIMETER SPACE DIMENSIONS AND STRUCTURAL COLUMN LOCATIONS PRIOR TO LAYOUT OF TENANT'S STORE. IF DISCREPANCY EXISTS, G.C. SHALL IMMEDIATELY CONTACT TENANT'S FIELD REPRESENTATIVE. IF SPACE DIMENSIONS AGREE WITH TENANT'S DRAWINGS, G.C. SHALL LAYOUT STORE FROM NUMBERED BENCHMARK'S AND /OR WORK POINTS PAYING SPECIAL ATTENTION TO DIRECTIONAL INDICATORS. ALL DIMENSIONS ARE TO BE HELD UNLESS OTHERWISE NOTED. DIMENSIONS LABELED AS EQUAL OR ± SHALL BE FIELD DETERMINED AND COORDINATED NI TN TENANT FIELD REPRESENTATIVE. T, NOTE: DIMENSIONS AT NEW PARTITIONS ARE REFERENCED TO FACE OF STUDS. DIMENSIONS AT DEMISING PARTITIONS ARE REFERENCED TO FACE OF DRYWALL. DIMENSIONS AT DOORS, OPENINGS, $ PREFAB. MILLWORK COMPONENTS ARE FINISHED DIMENSIONS. al. , NOTE: SEE SHEET 'A.2.10' FOR DOOR INFORMATION CONTINUATION OF BENCHMARK NO. 5 BENCHMARK NO. 4 BENCHMARK NO. 3 q2' -10g'I FLOCK PL,A\ SCALE: 1/4" = 1 II CONTINUATION OF BENCHMARK NO. 3 BENCHMARK NO. 2 BENCHMARK NO. 1 (BOTH SIDES) PAINTABLE FlRESTOP SEALANT 5/8' GYPSUM BOARD CEIUNG - -FINISH PER 5ClZDULE - 5/8' GYPSUM BOARD TYPE (BOTH SIDES) THE FalAVING FASTENING REa1FIFYQlfE !IRE TAHQ1 FT 4 UL's SEaRCA1lN FOR 1 RERCATEL AaEFI®LY. REFER TO S DOC1111217KNA FEN REWREEEN1S ANO Mi NTH 8Y s awn 5/8' T1ppf, 4 FT xmE ATTACHED TO STEE7. Sm6S AND ROM NW CEILING 18A0I N1N 1 Rt. ux4G, TYPE S STEEL SERE115 8.8G ED 8 N. OC. &MG Ma MD G BOARD. ' J gNTS [RENTED � ,ENNGILT NO STAGGERED DIE CRONTE NOES OF TEE 8.585SL1C -- TIE WAINSCOT, THIN -SET (WHERE OCCURS) --- - s' STEEL STUDS ®16" O,C. - -WALL HASH PER SCHEDULE - s' CONTINUOUS UNPUNCHED STEEL TRACK FLOOR FINISH Y ERE OCCURS - . SEALED CONCRETE SLAB, SEE STRUCTURAL DRAWNGS 1 HOUR PARTITION AT FINISHED CORRIDOR -PALATABLE FIRESTOP SEALANT (BON SIDES) RAMSET AS REQUIRED WHERE WALL ABUTTS A TENANT SPACE, GYPSUM BOARD LAYERS SHALL BE SUPPLIED AND INSTALLED BY TENANT - -- PAINTABLE FIRESTOP SEALANT (BOTH SIDES) - - - - UNDERSIDE OF DECK ABOVE - 5/ OEFLECn°N GAP - ---- -- s'isLOTTID TRACK (SUP - TRK EQ) - . • FINISH PER SCHEDULE CERING BY TENANT (NiTERE OCCURS) - 8' STEEL STUDS 9 16' G.C. - 5/8" Gypsum BOARD TYPE 'D" (BOTH SIDES) THE FOLLOWING FASTENING REQUIREMENTS ARE TAKEN FROM UL'S SPECIFICATION FOR THE INDICATED ASSEMBLY. REFER TO LA'S DOCUMENTATION FOR COMPLETE ASSEMBLY REQUIREMENTS AND ALLOWABLE OPTIONS: GYPSUM BOARD; 5 /E' THICK, 4 FT 1MDE, ATTACHED TO STEEL STUDS AND FLOOR AND CEILING TRACK NTH 1 IN. LONG, TYPE 5 STEEL SCREWS SPACED 8 IN. OC. ALONG EDGES OF BOARD AND 12 IL QC IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. RAMSET AS REQUIRED 8" CONTINUOUS UNPUNCHED STEEL TRACK FLOOR MASH -- - CONCRETE SLAB, SEE STRUCTURAL DRAYANGS - PAINTABLE FRESTOP SEALANT (B0111 SIDES) d9IE; A1L GYPSUM BOARD LAYERS SHALL BE SUPPLIED AND INSTALLED BY TENANT 1 HR TENANT DEMISING PARTITION (TYPICAL)I ,.fn. 22' -10 STRUCTURAL COLUMN INDEX KEY NOTES NOTE: SEE PLAN SECTION AT STOREFRONT A/A.2.4 FOR MORE DETAIL NOTE: G.C. SHALL COORDINATE CONSTRUCTION AREA OF STOREFRONT ENTRY WITH REQUIREMENTS OF ANTI -THEFT CONSULTANT'S DETECTION EQUIPMENT. LEASE LINE fi STRUCTURAL COLUMNS - IF REQUIRED BY LANDLORD OR BUILDING DEPARTMENT, \/ COVER WITH 5/8" TYPE 'X' DRYWALL OVER METAL STUD FRAMING TO STRUCTURE ABOVE AND FIRE SEAL FOR A ONE HOUR RATING. IF EXISTING, REPAIR ANY DAMAGED FIRE PROOFING TO MAINTAIN FIRE RATING. STOCKROOM - G.C. TO APPLY SEALER TO CONC. FLOOR SLAB IF REQUIRED. FURNISH AND INSTALL CB -3o] THROUGHOUT. PRIME FINISH ALL DRYWALL PARTITIONS. TOILET ROOM(S) - CAULK AROUND FLOOR DRAIN AFTER VGT IS INSTALLED OVER WATERPROOF MEMBRANE, LATICRETE #8235. USE LATEX TYPE ADHESIVE. INSTALL PLATFORM ABOVE AS PER DETAIL D /A.O.Ia CONCEALED WALL STANDARD - INTEGRATED METAL STUD WITH SLOTTED STANDARD FURNISHED BY TENANT AND INSTALLED BY G.G. SEE DETAILS ON SWEET 'A.2.7' AND ELEVATIONS ON SWEET 'A.2.6' FOR SIZED LOCATION. RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER Wslfie/i[ CE Working Drawing Review Approved Approved as Noted p Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verged by the Tenant's Architect and/or Cordractor. Tenant is responsible for complying with all government regulations. One (1) copy ofthls landlord stamped set of drawings is requirrto r be kept on the job site at all times, J Sldned Date t E-+ p4 Pt e n "FjOc E° N W �,�� bA t con N � z 0_ 1-Z 0 0 1 Drawn by: Store No. 275 A roved Drawing No. tel trf 0 1— z W 0 0 .0.1 a NO E: + FAUCET CONTROLS $ FLUSH VALVE ON TOILET SHALL BE OPERABLE WITH ONE HAND $ SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5L3F. + BLOCKING REQUIRED FOR GRAB BAR, PAPER TOWEL HOLDER AND TOILET PAPER HOLDER + PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM t WALL PRIOR TO PAINTING_ A.O.Ia PAPER TOWEL HOLDER EXISTING DEMISING PARTITION t \ G.G. TO INSULATE H0T WATER $ DRAIN PIPES it ENSURE THERE ARE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORY. A.O.Ia NOT TO S CFC -3] MIRROR y 2 GRAB BARS H.C. WATER I' -6" CLOSET H.G. TOILET ROOM DETAIL G A.O.Ia TOILET ROOM PLAN SCHEMATIC / -3I-O' SURFACE MOUNTED WALL STANDARD @ 4' -0" A.F.F. (UNFINISHED) FURN. BY TENANT, INST. BY G.C. (TYP) NEW 3 5/8" METAL STUDS WHITE FRP PANEL WAINSCOTING TOILET PAPER HOLDER B A.O.Ia EXISTING DEMISING PARTITION 6005200 -43 WITH 2 - #IO TEK SCREWS 0 EACH STUD WHITE FRP PANEL WAINSCOTING PAPER TOWEL HOLDER G.C. TO INSULATE HOT WATER $ DRAIN PIPES 4 ENSURE THERE ARE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORY. A.O.Ia CFC -3] SCALE: 1 " ■1' -O" MIRROR METAL STUD BLOCKING AS REVD (TYP.) N.C. TOILET ROOM DETAIL SECTION AT LEDGER TO EXISTING DEMISING PARTITION ATTACI-IMENT 3' -0" SURFACE MOUNTED WALL STANDARD 0 4' -O" A.F.F. (UNFINISHED) FURN. BY TENANT, INST. BY G.G. (TYP) GRAB BAR H.G. WATER CLOSET N.C. TOILET ROOM DETAIL SCALE = I/2" 1' -0" WHITE FRP PANEL WAINSCOTING GRAB BAR7 3 1_ 3 11 4' -6" • (MIN) OF TOILET PAPER HOLDER i" O.S.B. PLYWOOD (MIN.) W/ #8X1" SCREWS BP -6" O.C. PANEL EDGES - 12" 0.C. FIELD 1/2" OR 5/5" DRYWALL NOTE: IF TRANSFORMER IS SHIPPED W/ ATTACHMENT FLANGES, FASTEN TRANSFORMER TO JOIST BLOCKING W/ MIN. (4) #10 TEK SCREWS 2x4 FLAT BLOCKING W/ (2)I/4 "40 BOLTS TO BOTTOM FLANGE OF TRANSFORMER (INSTALL PRIOR TO PLACING TRANSFORMER) $ EXTEND 2x4 MIN. 6" PAST EACH SIDE OF TRANSFORMER FOR ATTACHMENT TO FLOOR STRUCTURE JOIST BLOCKING WATER HEATER TRANSFORMER -BY OTHERS CEILING JOISTS -REF. DETAIL G /A.0.1a (2) #10 TEK SCREWS FROM 2x4 BLOCKING TO CEILING BLOCKING AT EACH END OF 2x4 TRANSFORMER ATTACHMENT 5/8" PLYWOOD DECK 6005200 -43 METAL STUDS — SPACED 2' -0" O.C. MAX. PER ICBO REPORT NO. 4443 A.O.Ia SCALE: I I' -0" 3/4" NONCOMBUSTIBLE PLYWOOD DECKING FURN. BY MILLWORK SUPPLIER, INSTALLED BY G.C. 6" METAL JOIST ! 24' O.C. BY G.G. A.0.Ia I" PLYWOOD (MIN.) WITH #10 TEK SCREWS 0 I' -0" O.C. 0 SUPPORTS AND EDGES NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 5/8" WATERPROOF DRYWALL (GREENBOARD) (I TOILET ROOM) CP -2] 5/5" TYPE 'X' DRYWALL (tri FIRE CORRIDOR) FIRE CORRIDOR TOILET ROOM FINISHED FLOOR TYP. PLATFORM ABOVE FIRE SECTION AT METAL JOIST TO NEV METAL STUD I X 4 CLEAT AROUND PERIMETER OF PLATFORM CP -27 5/8" TYPE 'X' DRYWALL CORRIDOR AND TOILET ROOfsl REVIEWED FOR CODE COMPLIANCE APPROVE , MAR 21 2ffl EUJLDIN = Drtri NOTE: ALIGN METAL JOISTS WITH METAL STUDS NEW 362SI62 -33 METAL STUDS SPACED 0 2' -0" 0.C. PER IC80 REPORT NO. 4843 fat. ,D MAR 0 5 2008 PERMIT CENTER 40 REGISTERED ,, ARCHITECT Open t structure ur type designs are r allowed . 0 t the use of common plenum returns within mall HVAC system FITTING ROOMS (104a) (TYP.) DRYWALL CEILING 11' -0" A.F.F. CP -3a7 PASSAGE (102a) DRYWALL CEILING 0 11' -0" A.F.F. CP -3a3 Ail supports to from structural beams and joists and not from deck above �-s A NOTE: SUSPENSION SYSTEM TO 8E AS MANUFACTURED BY USG INTERIORS, INC. ANY ALTERNATE MUST BE APPROVED BY TENANT_ ICBO # ERIgg4 FIRE RATED C- CHANNEL AT PERIMETER I- I /2 "xl -I /2" FIRE RATED - HEAVY DUTY CROSS TEES 0 16" O.C. DRYWALL SUSPENSION SYSTEM NOT TO SCALE i i g : shall comply with Seismic bracing requirements for region_ J. 23' -2" 12 A. VERTICAL HANGER WIRE TO STRUCTURE ABOVE 0 4 -0" D.C. . - ID WO w Fire D stock mom shelving height. a i l from ce o top of shelving i deflector t_ 3/16" QUICK LINK WHITE FINISH (TYP) SCALE: 3 m 1' - 0" 3" LONG EYE BOLT WHITE FINISH (TYP) 5/8" DRYWALL OVER 5/8" PLYWOOD CP -3a3 (TYP) 3 PREFAB GRID SYSTEM PREFINISHED WHITE. SEE GRAPHIC HANG GRID KEY FOR SIZES_ (TYP) Track tc light i w be places } recessed storefront and - ward s = f � : 10a" REFLECTED CEILING PLAN PREFAB GRAPHIC GRID ASSEMBLY DETAIL RE -SAWN WOOD PLANK CEILING AND BOX BEAM ASSEMBLY SEE DETAIL E/A.2.8 (TYP) NOTE: G.G. SHALL COORDINATE DRYWALL CEILING SUSPENSION SYSTEM WITH LIGHTING LAYOUT, DIFFUSER AND RETURN AIR LOCATIONS, ACCESS PANELS LOCATIONS ETC. REPORT CONFLICTS TO TENANT FIELD REP. IMMEDIATELY. Verify w We t ' ick Tenant C fd� a location's f access panes to adI�. s equipment A sprinkler y' .I I kl i ; forward �. concealed f cover type_ area are to be KEY NOTES: SALES /FITTING ROOM CEILING - SHALL BE 5/8 TYPE 'X' DRYWALL CP -3a] OVER DRYWALL SUSPENSION SYSTEM AS MANUFACTURED BY USG INTERIORS, INC. OR APPROVED EQUAL - SEE DETAIL A /A.0.2. DRYWALL CEILING TO 5E CONTINUOUS FROM STOREFRONT BULKHEAD TO SALES /STOCK PARTITION. PROVIDE BLOCKING ABOVE CEILING AS REQUIRED TO INSTALL PREFAB. CEILING BEAMS. G.C. SHALL FURNISH AND INSTALL ACCESS PANELS CP -3] FOR ABOVE CEILING MAINTENANCE. SEE REFLECTED CEILING PLAN FOR LOCATIONS. FURNISH AND INSTALL ADDITIONAL ACCESS PANELS AS REQUIRED FOR ANY ADDITIONAL ABOVE CEILING MAINTENANCE POINTS THAT MAY BE EXISTING (G.C. TO VERIFY IN THE FIELD). PRIOR TO INSTALLATION OF ADDITIONAL ACCESS PANELS COORDINATE LOCATIONS WITH TENANT REPRESENTATIVE. 1 STOCKROOM CEILING - NO CEILING, UNLESS REQUIRED BY LANDLORD OR� LOCAL BUILDING CODES - G.C. SHALL FURNISH AND INSTALL USG INTERIORS, INC. 'AURATONE', FIRECODE, OMNI FISSURED PATTERN 2'x4' ONE HOUR RATED, LAY -IN, SUSPENDED CEILING #33q- WHITE. SUSPENSION SYSTEM SHALL BE AS MANUFACTURED 13Y USG INTERIORS, INC. DONN CEILING SUSPENSION DXL SERIES, WHITE EXPOSED 2'x4' GRID SYSTEM. SIGN - FURNISHED BY SIGN CONSULTANT, INSTALLED BY G.C. SEE SHEET A.2.12 FOR MORE INFORMATION. r r s na e must n separate circuit and on 7 y time clock set mars operating `s. PENDANT LIGHT I �- T.B.D. 5/8' TYPE DRYWALL 50-40 CP -3a] (TY 18 "x18" A ANUFAC IND -LOC HALL BE do R -APO!! c h i d ( P.) :ESS PANEL AS URED BY - PANEL STEALTH PANEL BY G.C. CP -3a] A storefront fighting must e incandescent and on separate r and on day time dock set mall's operating hours_ A .1 , There must be ceiling: See note on this sheet CITY OF TUKWILq litStfiekt FEB 0 4 2008 Working Drawing R M/i T CENTER gt Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual Field conditions are required to be verified by the Tenant's Architect and/or Cont Tenant is responsible for complying with all govemment regulations. One (1) copy of this landlord stamped set of drawings is requirto be kept on the Signed Date STOCKROOM (1050) I -IC . TOILET ROO DRYWALL CEILING flit 6' -0" A CP -2] SEE DET D /A.0.1a Install recessed alcove light SEAM IN WALLPAPER CENTER LIGHT FIXTURE ABOVE IN CEILING PANEL IGHT FIXTURE FITTING ROOM 6 ROOMS) N. W 11 SILVER - TEXTURE 1 1 WALLPAPER FINISH - ,, ,'�` ...,,=-_-=-, 1 1 1 1 ,, ., x I! max, 61 ` : H Lay in acoustical tiles ceiling may not selling n forward . Tiles have noise u coefficient o r .60 - 0.x"0 with minimum rc i room tt u facer 6140.0 decibels and must a code, flame I\ spread, fuel and ,smoke development motors. I i r -.,_ ,... �.., -._ r. I -- r- 1 ` - - -- F; I I_ T r` E I r- r i r i f ii; I I 1 -- l - r_.- { _. r - I ._ r _. 1 _ 1 - _� - . -_ -- 1i..,_..r i 1 f- 1- rr" -r- _r-.1_ _. r .. 1 _ E - f r -- r -- C E FITTING ROOM CEILING TRIM ASSEMBLY - SEE PET. N /A.2.B PREFAB ARCH - SEE PET. B/A.2.7 4 ELEVATIONS ON SHEET 'A.2.6' HIDDEN LIGHT FIXTURE LOCATED WITH! CASEWORK COMPONENTS. SEE DETAILS ON 5HEET 'F.2.3' (TYP OF 2) 4711 1 ,,. 10 -0' A.F.F. CP -4a] 10' -0' A.F.F. CP -4a] Pendant light at storefront must be raised because door height is to be 1 O' -0� VESTIE$ULE (103a DRYWALL CEILING 0 A.F.F. CP -4a] MISIESA 10 -0' A.F.F. CP -4a] PREFAB. CEILING BEAM ASSEMBLY SEE DET. G /A.2.8 (TYP) PREFAB. CEILING BEAM ASSEMBLY SEE DET. E/A.2.7 (TYP) NEW GRAPHIC HANG GRID KEY GRID NO. GRID SIZE COLOR Ga - 1 3' -0" x 5' -0' WHITE Ga -2 2' -O' x 3' -O" WHITE Ga -3 4 - t7" x 5' -0" WHITE Ga -4 4' -0" x 5' -0" WHITE SEE DETAIL AA/A.0.2 FOR MOUNTING DETAILS. IF GRID EXCEEDS 4' -O" IN ANY DIRECTION ADD GRIP SUPPORTS AT CENTER OF THE SPAN. DRYWALL A.F.F. (LING ( 4) FURN. BY TENANT, INST. EY G.G. WITH DRYWALL TOGGLE BOLTS THRU METAL STUD BLOCKING (TYP) PREFAB. CEILING SEAM ASSEMBLY CP -43 BOT. 0 IO' -4" A.F.F. SEE DET. D /A.2.8 (TYP) Ta -I Ta -I 16 .F.F. CP -43 VONA !NM z 0 z LU 0 ESEEZIMMEI REM a F-4 1-4 F�1 v-V; h g 0 L < m co r �3 o X 751 D No. A 1 111111 I I 15' --O" A.F.F. 14' -0" A.F.F. STOREFRONT TRIM: BRICK SOLDIER COURSE STOREFRONT TRIM: HEADER ROW LEASE LINE 0 GLASS TILES FURN. BY TENANT INST. BY G.C. (TILES 51-1ALL BE BUTTED TIGHT WITH NO GROUTING AND NO THIN SET SHOWING) (TYP) s� I E ,� E , e E , F I ! III � I`'I'� I I ` 1 ` I, { 'I I 1 I I Ir B � !_ i ! ff �! c II ! sl I :'1 .I �. i sl .E I :I s €. �9 � ,. I� �o ,. If � � E LIE � { { J ,{ {9 - • ' al - kg ...� + E • ,..= � � —--=- _ _ r te ... 'Z''',_ ,- � = "J-�` _ .7C_ .S T S- =Tt -••+,_ =C -r ,.� -, - _ic PREFAB. BRICK CBR -la] (TYP.) fij I -Or a CP -Ia] I/2 TEMP. PLAT GLASS (TYP) DECAL (TYP.) nnnnnnnnnnnnnnnn STOREFRONT BASE TRIM: BRICK SOLDIER COURSE t nnnnnnnnnn MALL FINISHED FLOOR a- r !1 Tf ! } f 1 t` i I I I I t ►I I ► I I I Ii Il i l t 1- . L.,,...,..r _�LiJL� � I._)I__:._iL. L�R.. .,.:I.__��IwL !_I...,,.5 - T 1E ► In l 11 ;r - ter" it r T n n B 2 LINE OF SALES AREA FLOOR BEYOND PREFAB. PUSH/ - PULL HARDWARE ON ENTRY DOORS SCALE : I /2" a II -011 WOOD TRIM CWD -la] CP -3a1 (TYP.) DEVICE BY OTHERS SCALE : i /2 z I' - OIL A A.2.5a I {II 11 1' LI_ L41 J..ii tu 1.3 L .T.. 1 -��I<T 1 -. • ..ir� ' . ,. .. -ryµ '._ Y- .. -r- ' t . . ,•• 1 GLAZED, PRESTAINED WOOD DOORS WITH CUSTOM PULLS ...,, E � I �' I � � i� - III f; I i II �I ! I iIIF { � { 7 p 1�1 G �{ ! ! ; i I Ip � I l E ; " 1 1( 1 E1 I i Jt�L II.1L_ LJ....IL L ..IE_.EL1E.�1.1L �l_ . r �l_ L.!L3 It LJ! rt�R!E J� IE �I � j l_ Li Oi LiLL�t._I! IL ILJ _ 7 r ir !(fi r- 11 OF PANEL AND SIGN •s . EDGE -LIT EXIT SIGN FURN. BY TENANT - INST. BY E.C. SCONCE LIGHT FIXTURE - FURN. BY TENANT, INST. BY G.C. (TYP) 1/2 TEMP. PLATE GLASS (TYP) PRESTAINED DOOR, SILL ri: GLAZING SYSTEM FURN. BY TENANT, INST. BY G.C. STOREFRONT ELEVATION PRESTAINED DECORATIVE POST (T(P) TOP OF DISPLAY WINDOW PLATFORM NT. STOREFRONT ELEVATION L _am II II ■. ■I 1 ID I 10 I MN =MI 1 I BENCH BY TENANT Th \_ TOP OF MALL FLOOR BEYOND nnnnnnnnn SALES AREA FINISHED FLOOR TI PREPAINTED WOOD — PANELS CWD - 3a] (TYP. ) DRYWALL CP -4a] (TYP) ,I PREPAINTED WOOD TRIM CWD -Ia] (TYP.) 1' CWD -2a] • • • CB -201 CP -la Y [B - la] CP - r i I TOP OF DISPLAY I ►WINDOW PLATFORM //; CWD - 3a] CP -Ia] SENSORMATIC 2" TEMP, PLATE GLASS AT ENTRY DISPLAY BEYOND DRYWALL CP -4a] LEASE LINE STOREFRONT TRIM: BRICK SOLDIER COURSE STOREFRONT TRIM: HEADER ROW PREFAB. BRICK CHR -la] (TYP.) DEMISING PARTITION LEASE LINE KEY NOTES: MALL NEUTRAL PIER NOTE: CONTRACTOR SH C U INS► PAINTING ALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM AND WALL PRIOR TO PAINTING. Dob .-05D (IQ) Q) SIGN - FURNISI-IED BY SIGN CONSULTANT, INSTALLED BY G.C. ` I SEE SHEET 1 A.2.I2' FOR MORE INFORMATION. DECAL - FACE ADHESIVE, INSTALLED ON STORE SIDE OF (28) GLASS, FURNISI - IED BY TENANT AND INSTALLED BY OTI - IERS GLASS CLIPS - G.C. SHALL FURNISH AND INSTALL CLEAR C IC GLASS CLAMPS AS MANUFACTURED 8 M I A RYL LA LA PS A Y MIRART. G THIS CONTRACTOR SHALL CONTACT MIRART AT 60O- 327 -8944 FOR INFORMATION. STOREFRONT FINISH NOTE: G.G. WILL FINISH ALL MILLWORK COMPONENTS WITH MILLWORKER SUPPLIED FINISHES IN STEPS AS FOLLOWS: I) SAND AND FILL ALL MILLWORK COMPONENTS WITH 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL I2CSW 8032 - ALLOW I -1/2 HOUR DRYING TIME 3) SAND WITH 220 GRIT SANDPAPER. WIPE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISH - PRATT LAMBERT HIGH GLOSS Z39 - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH SOO GRIT SANDPAPER. WIPE WITH TACK RAG. 6) BRUSH OR ROLL ON DULL FINISH - PRATT 4 LAMBERT DULL 23 11 ONO FOR CODE COMPLIANCE 1 1I1M3 Cis Of, 1'001 BUILDING DNISION FEB 2 9 2008. 34 BRICK APPLICATION NOTE: • INDIVIDUAL BRICK PIECES SHALL BE APPLIED TO DRYWALL SURFACE 'MITI 3M" MORTAR GAPS. • mow SHALL BB A 1a MIX OF WHIM MORTAR TO WHIM SAND BY G.C. ▪ MORTAR '10 BB BAG APPLIED AND SHALL BE "THUMB" STRUCK TOOBTAIN BIREGIn4R JOINT CONSISI'@ICY. • COORDINATE wrm TENANT FIELD REP. REGISTERED ARCHITECT EN H L. BUTTS STATE OF WASHINGTON r1RrZ E0 5 2008 PERMIT CENTER NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY SAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT, Drawn 0 -p zg4 O ON ce.1- q ad !► ig& 41p ,Acio trz 7 I-] W fY 'Ii 0 U) W 0 n r ;.2_":. x ' 1= - -- :.z. =.- r --- - . _ T . . C_. .=C . S A x_ S _ - .-. = . - . . ._ .T .= - - .�- -= �=-x z -- - - ' „..2"1-.-4-72:-L. � 0 I/2" TEMP. PLATE 7 GLASS (TYP) 0 15' --O" A.F.F. 14' -0" A.F.F. STOREFRONT TRIM: BRICK SOLDIER COURSE STOREFRONT TRIM: HEADER ROW LEASE LINE 0 GLASS TILES FURN. BY TENANT INST. BY G.C. (TILES 51-1ALL BE BUTTED TIGHT WITH NO GROUTING AND NO THIN SET SHOWING) (TYP) s� I E ,� E , e E , F I ! III � I`'I'� I I ` 1 ` I, { 'I I 1 I I Ir B � !_ i ! ff �! c II ! sl I :'1 .I �. i sl .E I :I s €. �9 � ,. I� �o ,. If � � E LIE � { { J ,{ {9 - • ' al - kg ...� + E • ,..= � � —--=- _ _ r te ... 'Z''',_ ,- � = "J-�` _ .7C_ .S T S- =Tt -••+,_ =C -r ,.� -, - _ic PREFAB. BRICK CBR -la] (TYP.) fij I -Or a CP -Ia] I/2 TEMP. PLAT GLASS (TYP) DECAL (TYP.) nnnnnnnnnnnnnnnn STOREFRONT BASE TRIM: BRICK SOLDIER COURSE t nnnnnnnnnn MALL FINISHED FLOOR a- r !1 Tf ! } f 1 t` i I I I I t ►I I ► I I I Ii Il i l t 1- . L.,,...,..r _�LiJL� � I._)I__:._iL. L�R.. .,.:I.__��IwL !_I...,,.5 - T 1E ► In l 11 ;r - ter" it r T n n B 2 LINE OF SALES AREA FLOOR BEYOND PREFAB. PUSH/ - PULL HARDWARE ON ENTRY DOORS SCALE : I /2" a II -011 WOOD TRIM CWD -la] CP -3a1 (TYP.) DEVICE BY OTHERS SCALE : i /2 z I' - OIL A A.2.5a I {II 11 1' LI_ L41 J..ii tu 1.3 L .T.. 1 -��I<T 1 -. • ..ir� ' . ,. .. -ryµ '._ Y- .. -r- ' t . . ,•• 1 GLAZED, PRESTAINED WOOD DOORS WITH CUSTOM PULLS ...,, E � I �' I � � i� - III f; I i II �I ! I iIIF { � { 7 p 1�1 G �{ ! ! ; i I Ip � I l E ; " 1 1( 1 E1 I i Jt�L II.1L_ LJ....IL L ..IE_.EL1E.�1.1L �l_ . r �l_ L.!L3 It LJ! rt�R!E J� IE �I � j l_ Li Oi LiLL�t._I! IL ILJ _ 7 r ir !(fi r- 11 OF PANEL AND SIGN •s . EDGE -LIT EXIT SIGN FURN. BY TENANT - INST. BY E.C. SCONCE LIGHT FIXTURE - FURN. BY TENANT, INST. BY G.C. (TYP) 1/2 TEMP. PLATE GLASS (TYP) PRESTAINED DOOR, SILL ri: GLAZING SYSTEM FURN. BY TENANT, INST. BY G.C. STOREFRONT ELEVATION PRESTAINED DECORATIVE POST (T(P) TOP OF DISPLAY WINDOW PLATFORM NT. STOREFRONT ELEVATION L _am II II ■. ■I 1 ID I 10 I MN =MI 1 I BENCH BY TENANT Th \_ TOP OF MALL FLOOR BEYOND nnnnnnnnn SALES AREA FINISHED FLOOR TI PREPAINTED WOOD — PANELS CWD - 3a] (TYP. ) DRYWALL CP -4a] (TYP) ,I PREPAINTED WOOD TRIM CWD -Ia] (TYP.) 1' CWD -2a] • • • CB -201 CP -la Y [B - la] CP - r i I TOP OF DISPLAY I ►WINDOW PLATFORM //; CWD - 3a] CP -Ia] SENSORMATIC 2" TEMP, PLATE GLASS AT ENTRY DISPLAY BEYOND DRYWALL CP -4a] LEASE LINE STOREFRONT TRIM: BRICK SOLDIER COURSE STOREFRONT TRIM: HEADER ROW PREFAB. BRICK CHR -la] (TYP.) DEMISING PARTITION LEASE LINE KEY NOTES: MALL NEUTRAL PIER NOTE: CONTRACTOR SH C U INS► PAINTING ALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM AND WALL PRIOR TO PAINTING. Dob .-05D (IQ) Q) SIGN - FURNISI-IED BY SIGN CONSULTANT, INSTALLED BY G.C. ` I SEE SHEET 1 A.2.I2' FOR MORE INFORMATION. DECAL - FACE ADHESIVE, INSTALLED ON STORE SIDE OF (28) GLASS, FURNISI - IED BY TENANT AND INSTALLED BY OTI - IERS GLASS CLIPS - G.C. SHALL FURNISH AND INSTALL CLEAR C IC GLASS CLAMPS AS MANUFACTURED 8 M I A RYL LA LA PS A Y MIRART. G THIS CONTRACTOR SHALL CONTACT MIRART AT 60O- 327 -8944 FOR INFORMATION. STOREFRONT FINISH NOTE: G.G. WILL FINISH ALL MILLWORK COMPONENTS WITH MILLWORKER SUPPLIED FINISHES IN STEPS AS FOLLOWS: I) SAND AND FILL ALL MILLWORK COMPONENTS WITH 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL I2CSW 8032 - ALLOW I -1/2 HOUR DRYING TIME 3) SAND WITH 220 GRIT SANDPAPER. WIPE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISH - PRATT LAMBERT HIGH GLOSS Z39 - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH SOO GRIT SANDPAPER. WIPE WITH TACK RAG. 6) BRUSH OR ROLL ON DULL FINISH - PRATT 4 LAMBERT DULL 23 11 ONO FOR CODE COMPLIANCE 1 1I1M3 Cis Of, 1'001 BUILDING DNISION FEB 2 9 2008. 34 BRICK APPLICATION NOTE: • INDIVIDUAL BRICK PIECES SHALL BE APPLIED TO DRYWALL SURFACE 'MITI 3M" MORTAR GAPS. • mow SHALL BB A 1a MIX OF WHIM MORTAR TO WHIM SAND BY G.C. ▪ MORTAR '10 BB BAG APPLIED AND SHALL BE "THUMB" STRUCK TOOBTAIN BIREGIn4R JOINT CONSISI'@ICY. • COORDINATE wrm TENANT FIELD REP. REGISTERED ARCHITECT EN H L. BUTTS STATE OF WASHINGTON r1RrZ E0 5 2008 PERMIT CENTER NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY SAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT, Drawn 0 -p zg4 O ON ce.1- q ad !► ig& 41p ,Acio trz 7 I-] W fY 'Ii 0 U) W 0 n ERICK E- la (1rno.) DEMISING PARTITION LEASE LINE CWD-203 CF-1131 CES-1a1 CP-IG] (TYP.) PLAN SECTION @ STOREFRONT SCALE: I I/2" 1' - 0" LINE OF BULL NOSE Storefront must be bumped out to lease line and also m • follow the lease line because of the type of storefront design > (type 4) Revise and resubmit storefront plan and elevation for review and approval. KEY NOTES: CONCEALED SLOTTED STANDARD - INTEGRATED METAL STUD WITH SLOTTED STANDARD FURNISHED BY TENANT AND INSTALLED BY G.C. SEE DETAIL G 4 H/A.2 .7 AND ELEVATIONS ON SHEET 'A-4' FOR SIZE AND LOCATION. NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM $ WALL PRIOR TO PAINTING. REGARDING GLAZING STOP ATTACHMENT G.C. SHALL FASTEN WOOD GLAZING STOPS 104/ 1±8 SCREWS 0 12" O.C. kV 5/8" MIN. EMBED. (TYP.) STOREFRONT FINISH NOTE: G.C. WILL FINISH ALL MILLWORK COMPONENTS WITH MI LLWORKER SUPPLIED Fl NI SHES IN STEPS AS FOLLOWS: I ) SAND AND FILL ALL MILLWORK COMPONENTS WITH 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL 12CSW q032 - ALLOW 1-1/2 HOUR DRYING TIME. 5) SAND WITH 220 GRIT SANDPAPER. WI PE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISI4 - PRATT $ LAMBERT HIGH GLOSS Z31:1 - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH 300 GRIT SANDPAPER. WIPE WITH TACK RAG. 6) BRUSH OR ROLL ON DULL FINISH - PRATT * LAMBERT DULL MR DOUBLE METAL STUD POST POST TO BE 6 16 GA. CC STUD Wstfieff Working Drawing Review „F( Approved Approved as Noted 0 Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect andfor Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requIr • to be kept an the lob site at a I/2/ 8/07 Si ned Date 16 GA. MT TRACK EACH SIDE TYPICAL DOUBLE STUD POST DETAIL RECEIVED CITY OF TUKVVILA FEB 0 4 2008 PERMIT CENTER • . • • , . . . . • . • • • . • . • . . • . . • . . • • • CB-2(23 ONLY /8" TYPE 'X' DRYWALL (TYP.) BRICK [13R-Ica] (TYP.) DRYWALL [P-4a] DISPLAY WINDOW PLATFORM C FC -70] CP -6a3 (TYP.) INSTALL IN D I R - - 3!4N 3/4 clear anodir •luim felitee should be in 41:ed between Landlords neutral pier ard vertical bulkhead soffits and Tenant's storefront des n Delete vertical mullion and use butt joint (1/4" gap) PRESTAINED GLAZING SYSTEM FURN. HY TENANT, INST. BY G.C. LINE OF (2) 6" STRUCTURAL METAL JOIST HEADERS ABOVE (TYP.) 1/2" TEMP. PLATE GLASS (TYP.) 7/8"X7/8" PRESTAINED WOOD TRIM (TYP) E15-2,23 DOUBLE 6." 18 A. (MIN.) METAL STUD COLUMNS TO SUPPORT HEADER ABOVE (TYP.) PRESTAINED GLAZING SYSTEM FURN. BY TENANT, INST. BY G.C. CB -203 FIELD FINISHED WOOD TRIM MD- 1 a] (SEE NOTE THIS 5 SHEET) FIELD FINISHED WOOD PANELS CIAJD-3] (SEE NOTE THIS SHEET) EQUAL. 7 MALL TILE LEASE LINE FIELD FINISHED WOOD PANELS CWD-3a3 (SEE NOTE THIS SHEET) 12F' NOTE: SEE SHEFr 'A.2.4 FOR CONTINUATION OF STOREFRONT PLAN 7 1 l • Drawing No. A.2.4 4.1 PRESTAINEO r SYSTEM FURN. BY TENANT, INST. BY G.C. VC -203 PRESTAINED DECORATIVE POST (TYP) PLUGMOLD 6Y ANTI -THEFT CONS LTANTS. (PAINT BROWN TO MATCH STAINED POST) A.2.5a Extend mall tile into vestibule area. Tile to match mall tile is type, color, size, thickness, grout color and installation direction. If there is cut tiles; cut tiles are to be removed and full tiles installed. Tenant is to test mall tile to insure Dove insert and be made. If not Tenant is to select a tile that is similar to Landlord's. Submit sample of tile to be used in this case for review and approval. A.2.5c DRYWALL EP -43 PVC CONDUIT $ FITTINGS UNDER TENANT FLOOR, FURN. BY ANTI -THEFT CONSULTANT, INST. 8Y E.C. (TYP 1 EACH ENTRY DOOR PAIR) 3 -6 FIELD FINISHED WOOD TRIM [WD -la] (SEE NOTE THIS SHEET) Kr NOTE: SEE SHEET 'A.2.4' FOR CONTINUATION OF STOREFRONT PLAN i" THICK ALUMINUM ANGLE TRANSITION STRIP LEASE LINE MALL TILE SCALE: I I/2" = I" - 0" NOTE: G.C. SHALL INSTALL ENTRY FLOOR TILE IN "RANDOM" PATTERN AS INDICATED ON THIS SHEET. LINE OF (2) 6" STRUCTURAL METAL JOIST HEADERS ABOVE (TYP. ) DISPLAY WINDOW PLATFORM CFC - 703 CP - 6a] (TYP.) INSTALL IN DIRECTION SHOWN PLAN SECTION @STOREFRONT LINE OF BULL NOSE [B -20] EP-la] DOUBLE 6" IS GA. (MIN.) METAL STUD COLUMNS TO SUPPORT HEADER ABOVE I /2" TEMP. PLATE GLASS (TYP.) FFAB BENCH FURN. 6Y ANT INSTALLED BY G.C. DETAIL B /A.2.443 M loose fixturing rnI st be we I behind the entrance door area No fixturing will be allowed over the leas= iine or y in the storefront alcove STEP DOWN • rr NOTE: SEE SHEET I A.2.4b' FOR CONTINUATION OF STOREFRONT PLAN FLOOR SCREWS KEY NOTES: CONCEALED SLOTTED STANDARD - INTEGRATED METAL STUD WITH SLOTTED STANDARD FURNISHED BY TENANT AND INSTALLED BY G.C. SEE DETAIL G I4/A.2.7 AND ELEVATIONS ON SHEET 'A -4' FOR SIZE AND LOCATION. NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM $ WALL PRIOR TO PAINTING. NOTE: REGARDING GLAZING STOP ATTACHMENT G.C. SHALL FASTEN WOOD GLAZING STOPS W/ #5 SCREWS 0 12" O.C. VI/ 5/8" MIN. EMBED. (TYP.) STOREFRONT FINISH NOTE: G.G. WILL FINISH ALL MILLWORK COMPONENTS WITH MILLWORKER SUPPLIED FINISHES IN STEPS AS FOLLOWS: I) SAND AND FILL ALL MILLWORK COMPONENTS WITH 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL I2CSW 8032 - ALLOW I -1/2 HOUR DRYING TIME. 3) SAND WITH 220 GRIT SANDPAPER. WIPE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISH - PRATT * LAMBERT HIGH GLOSS Z3 - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH 300 GRIT SANDPAPER. WIPE WITH TACK RAG. 6) BRUSH OR ROLL ON DULL FINISH - PRATT 4 LAMBERT DULL 25 BENCH BACK LEG DRYWALL SCREW (INSIDE LEG) FLOOR PLATE FLOOR SCREWS Wstfie[d TYPICAL BENCH PIN DOWN DETAIL Si.ned Date Working Drawing Review A Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations One (1) copy of this landlord stamped set of drawings is requir- • to b kept on the job site at a I BENCH FRONT LEG DRYWALL SCREW (INSIDE LEG) FLOOR PLATE RECEIVED CITY OF TUKWILA FEB 0 4 2088 PERMIT CENTER A.2.4b 0 U- U--L OZ 0 0 F- LU 0_ Delete wing wall here to make storefront more transparent 1'x 3/4" 'dear anodized alum reveals should be installed between Land `s F 1 pier and verh bullchead soffits d Teianrs storefront design I -0' STEP DOWN i 4 DRYWALL CP -421 DISPLAY WINDOW PLATFORM CFC -7a3 CL' -6a}- fTYP -- - INSTALL IN DIRECTION SHOWN Er NOTE: SEE SHEET 'A.2.4a' FOR CONTINUATION OF STOREFRONT PLAN CB -2a] DRYWALL CP -403 SCALE: 11/2" 1' - 0' 5/8" TYPE 'X' DRYWALL (TIP_) 3 5/3" METAL STUD FRAMING AS REQ'D (TYP.) BRICK CBR -la] (TYP.) CB -2a] ?LAN SECTION STOREFRONT BRICK [13R-Ia] (TYP.) FIELD FINISHED WOOD PANELS CWD -3a] (SEE NOTE THIS SHEET) DEMISING PARTITION LEASE LINE FIELD FINISHED WOOD TRIM CWD -la] (SEE NOTE THIS SHEET) KEY NOTES: EXISTING LANDLORD'S NEUTRAL PIER. CONCEALED SLOTTED STANDARD - INTEGRATED METAL STUD WITH SLOTTED STANDARD FURNISHED BY TENANT AND INSTALLED BY G.C. SEE DETAIL G $ 14/A.2.7 AND ELEVATIONS ON SHEET 'A -4' FOR SIZE AND LOCATION. NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM $ WALL PRIOR TO PAINTING. NOTE: REGARDING GLAZING STOP ATTACHMENT G.C. SHALL FASTEN WOOD GLAZING STOPS W/ #S SCREWS 0 12' O.C. W/ 5/5" MIN. EMBED. (TYP.) SZOREFRONT FINISH NOTE: G.C. WILL FINISH ALL MILLWORK COMPONENTS WITH MILLWORKER SUPPLIED FINISHES IN STEPS AS FOLLOWS: I) SAND AND FILL ALL MILLWORK COMPONENTS WITH 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL I2CSW 8032 - ALLOW I -1/2 HOUR DRYING TIME. 3) SAND WITH 220 GRIT SANDPAPER. WIPE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISH - PRATT $ LAMBERT HIGH GLOSS Z3q - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH 300 GRIT SANDPAPER. WIPE WITH TACK RAG. 6) BRUSH OR ROLL ON DULL FINISH - PRATT $ LAMBERT DULL Z3q 1)05.050 Si.ned Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect andfor Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings requir -, to be o kept on the job site IT2/2 Date LU 0 4 21i0 J PERMIT CENTER Co 0 Bold lines are what Landlord will be building. Tenant is to intergrate their storefront- with'_Lan_d ord` bulkhead. See Tenant Criteria tardr- tion� ta=e-f -r-on# T e 4 -- AERIE Southcenter Mall Tukwila WA Space # 2120 AMERICAN EAGLE OUTFITTERS 150 Tharp Hill Dr. - P.O. 788 W iii edale, Pa. 15095 (724) 776 -4857 -k• �i`ry .i .vr. . u ==• GLASS TILES FURN. BY TENANT INST. BY G.G. (TILES SHALL BE BUTTED TIGHT WITH NO GROUTING AND NO THIN SET SNOWING) FLUORESCENT LIGHT FIXTURE FURN. BY TENANT, INST. BY G.C. Verify ADA and code compliance SCONCE LIGHT FIXTURE - FURN. BY TENANT, INST. BY G.C. (TYP) 1/2' TEMPERED PLATE GLASS PREFINISHED GLAZING SYSTEM FURN. BY TENANT, INST. BY G.C. (DARK STAINED) 1/4' TI -TICK ALUMINUM ANGLE TRANSITION STRIP MALL FINISHED FLOOR Storefront design at to have finished return - d hide cove light fi ree 3 #8 SCREWS (TYPICAL) Elir III 16AFF ■' r<_ «� « «ifti «�i t7� «ITIirii i :i « «�:iIIr i:i < «<i°i < <ir «:fiAr<<s: EsrE2s.4 «��r"-r P hi — ------ l �4" ` «i��� « �_�_ LEASE LINE MALL CEILING MALL BULKHEAD MALL LIGHT COVE DRYWALL CP -3a] (TYP) BRICK SOLDIER COURSE [BR- la] (TYP. ) BRICK CBR -10] (TYP.) VARIES NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON TH15 SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. ail 4 ARIE I MIN. REQ'D. VARIES , ! F 11 - I F 1 1 - i L ____ F i_.._ 1 ._., . .__.____.GRA.�i'l41.C_�l.I LAY LRJA xSTF...L'� . L J I 3 5/8 ,t4 18 A. MT —. . � _._. I i .FORK; B gN NT, - INST. E i _ _ __._._1TR G-1:; --- _ r _, 1.._G c u_F_A ITA_ IL. ./ .Q..2; L.____.. _____i L . �.T.__._. L___._ , . i - 1 -- I } -� E I #8 5 ZEWS a I' -4'- - 1 SURFACE 1 LIGHT 1 I 1 r - - - - IR: RACK ` ._ _TRACIC.F1XITiU:R.E._.�....FJ IRN�_i L.______ _.._.._____, ?- .-- .___...__.__ ___ � E4DE_ R, TYP�I - �_..__.._____._.__ _ Bel . LEFNTrEE:c. I,e�NT, I r— a_ , - -- jr ! JI I L NOTE: MALL BULKHEAD SHOWN IS FOR SCHEMATIC PURPOSES ONLY. ALWAYS BUILD STOREFRONT CONSTRUCTION TO ACTUAL LEASE LINE. VERIFY WITH MALL MANAGEMENT PRIOR TO START OF ANY WORK. Tenant is to supply Type XX gypbd d or Tenants side of Landlord bulkhead a. stratum, and pinvide tmling as required by code_ _ 3 5/8" CC 18 GA. METAL STUD DIAGONAL BRACING 0 4' -0" O.C. - ATTACH BRACE TO STRUCTURE ABOVE SEE DETAIL G /A .2.5d (SIM.) 3 5/8" X18 GA. CC DIA. STUD BRACE SIMILAR TO DETAIL D /A.2.5d SECURE TO CONC. SLAB WITI -I .145" 0 HILTI PIN 1 1/4" EMBEDMENT IN CONCRETE SLAE 32 O.C. ICSO 2366 SECTION TOP OF DISPLAY WINDOW PLATFORM [FC -7a] CP -6a] STOREFRONT FINISH NOTE: G.C. WILL FINISH ALL MILLWORK COMPONENTS WITH MILLWORKER SUPPLIED FINISHES IN STEPS AS FOLLOWS: I) SAND AND FILL ALL MILLWORK COMPONENTS WITI-4 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL 12CSW 9032 - ALLOW 1 -1/2 HOUR DRYING TIME. 3) SAND WITH 220 GRIT SANDPAPER. WIPE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISH - PRATT $ LAMBERT HIGH GLOSS Z3G1 - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH 300 GRIT SANDPAPER. WIPE WITH TACK RAG. 6) BRUSH OR ROLL ON DULL FINISH - PRATT 11 LAMBERT DULL 23 [FC -1a] SALES AREA 35/8 "X18GA. MT TRACK, TYP. FASTENED SECURELY ATTACHED TO TOP CHORD OF BAR JOIST DIAGONAL WALL BRACE SEE DETAIL C/A .2.5d 3 5/8" X 18 GA. CC METAL STUD FRAMING 0 16" O.C., TYP. 3 5/8" X 16 GA. MT TRACK, TYP 2 -tB SCREWS EACH STUD (TYP) IF REQ' D. BY LANDLORD OR BUILDING DEPT. - G.G. TO EXTEND DRYWALL TO UNDERSIDE OF DECK ABOVE AND FIRESEAL (FOLD) SUSPENDED CEILING SYSTEM WOOD TRIM CWD -la] CP -313 (TYP.) DRYWALL CP -4a] (TYP) CWD -2a] [P -Ia] 1 j SIGN FURNISI -#ED BY SIGN CONSULTANT - INSTALLED BY I G.C.SEE SHEET 'A.2.12' FOR MORE INFORMATION. vita' NOTE: LANDLORD'S BULKHEAD CONSTRUCTION INCLUDING BUT NOT LIMITED TO, SOFFIT, DUCTWORK, PIPING, LATERAL STRUCTURAL BRIDGING, ROOF DECK ETC. SHALL NOT BE USED TO SUPPORT TENANT'S STOREFRONT. G.C. SHALL DIAGONALLY BRACE STOREFRONT FRAMING TO BUILDING STRUCTURE WITH 3 5 /8 "x 20 GA. METAL STUDS AT 48" O.C. or NOTE: IF REQUIRED BY LANDLORD OR BUILDING DEPARTMENT, G.G. SMALL FURNISH AND INSTALL 5/8' TYPE 'X' FIRECODE DRYWALL TO STRUCTURE ABOVE AND FIRE SEAL FOR A ONE DOUR RATING. gar NOTE: . • r REGARDING GLAZING STOP ATTACHMENT: G.C. SHALL FASTEN WOOD GLAZING STOPS WITH #8 SCREWS 0 12" O.C. WITH 5/8" MIN. EMBEDED TYP. . If AMERICAN EAGLE 12/24/2007 6: 50:42 AM 1 m AR storefront design must be iridependtly supported from the fl structure. Landlord's man bulkhead can oft be used for lateral support_ GLASS TILES FURN. BY TENANT INST. BY G.C. (TILES SHALL BE BUTTED TIGHT WITH NO GROUTING AND NO THIN BET SHOWING) 15' -0" ABOVE MALL FLOOR 10' -o" ABOVE MALL FLOOR L iammwo i1 \l \ 1\1\1\1\ ALIGN FIELD FI WOOD P FWD -3a] ISHED NELS TYP.) MIN. REVD. BRICK [BR -1a] (TYP.) 3 #8 SCREWS (TYPICAL) STOREFRONT BASE TRIM: BRICK CBR -1a] SOLDIER COURSE Storefront door is ow 10' -0" high. Raise pendant mounted I` ;gh fixture to clear doo 5/8" TYPE 'X' DRYWALL CFC -2a] snl'V" n •Ico 10' -0 3/4" A.M.F. (HOLD) 14' -0" ABOVE MALL FLOOR FIELD FINISHED WOOD TRIM [WD -la] (TYP.) 1/2" CEMENT BOARD BY G.C. FLUORESCENT LIGHT FIXTURE FURN. BY TENANT, INST. BY G.C. FIELD FINISHED WOO TRIM C141D -10] (TYP.) SCONCE LIGHT FIXTURE - FURN. BY TENANT, INST. BY G.C. (TYP) PREFAB. METAL PLAQUE FURN. BY TENANT, INST. BY G.G. SEE SHEET A.2.12 FOR MORE DETAIL MALL FIELD FINISHED WOOD TRIM CWD -1a] (TYP.) FIELD FINISHED WOOD PANELS CWD -30] (TYP.) 1/4" THICK ALUMINUM ANGLE TRANSITION STRIP MALL FINISHED FLOOR LEASE LINE / 11 MALL CEILING MALL BULKHEAD MALL LIGHT COVE BRICK SOLDIER COURSE CBR -la] (TYP.) BRICK CBR -la] (TYP.) DRYWALL CP -30] (TYP) 'c 'm —icti ZD Cs� Q NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 1i I I Ii Li it II NOTE: MALL BULKHEAD SHOWN IS FOR SCHEMATIC PURPOSES ONLY. ALWAYS BUILD STOREFRONT CONSTRUCTION TO ACTUAL LEASE LINE. VERIFY WITH MALL MANAGEMENT PRIOR TO START OF ANY WORK. 3 5/8" CC 18 GA. METAL STUD DIAGONAL BRACING 0 4' -0" O.C. - ATTACH �- i BRACE TO STRUCTURE .� r i ABOVE SEE DETAIL � ) 1 r '. C /A.2.5d (SIM.) CI J______. a1 +1- SECTION SCALE: 11/2" 1' - 0" 5/8" X 18 GA. CC DIA. STUD BRACE SIMILAR TO DETAI D /Ar2.5d • sZk STOREFRONT FINISH NOTE: G.C. WILL FINISH ALL MILLWORK COMPONENTS WITH MILLWORKER SUPPLIED FINISHES IN STEPS AS FOLLOWS: 1) SAND AND FILL ALL MILLWORK COMPONENTS WITH 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL =SW 9032 - ALLOW 1 -1/2 HOUR DRYING TIME. 3) SAND WITH 220 GRIT SANDPAPER. WIPE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISH - PRATT $ LAMBERT HIGH GLOSS 13q - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH 300 GRIT SANDPAPER. WIPE WITH TACK RAG. 6) BRUSH OR ROLL ON DULL FINISH - PRATT $ LAMBERT DULL Z39 SALES AREA CFC - KEY NOTES: EXISTING TOP CHORD OF JOIST 3518 " X1B GA. MT TRACK, TYP. FASTENED SECURELY ATTACHED TO TOP CHORD OF BAR JOIST DIAGONAL WALL BRACE SEE DETAIL C /A.2.5d 3 5/E0 X 18 GA. CC METAL STUD FRAMING 0 16" O.C., TYP. 3 5/8" X 18 GA. MT TRACK, TYP. 2 - #8 SCREWS EACH STUD (TYP) I F REQ'D. BY LANDLORD OR BUILDING DEPT. - G.C. TO EXTEND DRYWALL TO UNDERSIDE OF DECK ABOVE AND FIRESEAL SUSPENDED CEILING SYSTEM (HOLD) WOAD • TRIM CWD -1a] CP -30] (TYP.) PREFAB. CEILING BEAM ASSEMBLY CP -4a2 (TYP.) DRYWALL CP -40] (TYP) Storefront door must be 10' -0" high FIELD FINISHED WOOD PANELS CWD -3a] (TYP.) PREFABRICATED CUSTOM DOOR PUSH /PULLS FURNISHED BY TENANT, INST. BY G.C. CB -10] CP -la] (TYP.) CB -203 CP -la] (TYP.) 11' -6" A.M.F. 11' -0" A.F.F. K SIGN FURNISHED BY SIGN CONSULTANT - INSTALLED BY G.C.SEE SHEET 'A.2.I2' FOR MORE INFORMATION. tar NOTE: LANDLORD'S BULKHEAD CONSTRUCTION INCLUDING BUT NOT LIMITED TO, SOFFIT, DUCTWORK, PIPING, LATERAL STRUCTURAL BRIDGING, ROOF DECK ETC. SHALL NOT BE USED TO SUPPORT TENANT'S STOREFRONT. G.C. 51-1ALL DIAGONALLY BRACE STOREFRONT FRAMING TO BUILDING STRUCTURE WITH 3 5 /8 "x 20 GA. METAL STUDS AT 48" O.C. I NOTE: IF REQUIRED BY LANDLORD OR BUILDING DEPARTMENT, G.G. SHALL FURNISH AND INSTALL 5/8" TYPE 'X' FIRECODE DRYWALL TO STRUCTURE ABOVE AND FIRE SEAL FOR A ONE HOUR RATING. or NOTE: REGARDING GLAZING STOP ATTACHMENT: G.C. SHALL FASTEN WOOD GLAZING STOPS WITH 1:18 SCREWS 0 12" O.C. WITH 5/8" MIN. EMBEDED (TYP.). .1K)1 (01 STOREFRONT SECTIONS AERIE Southcenter Moll Tukwila IiIA Spec # 2120 �' :.:_...� ... r.........,...,.r c .1� .......i..... s. �v... _...r. i .i _ ...r....r . -- sw..'.:C :;.7F.'ti:h�nx...........,r:.l! `f.`,�w...... �.....±�% }.. 1 h TH L�BUTTS, ARCHITECT Bell C� CA 91307 818_ 72 ,r• 4; AMERICAN EAGLE OUTFITTERS 150 'Thom Hill Dr. - P.O. 788 Waffendale, Pa 15095 (724) 776 -4857 ... r...... ..... _. �..... :....... n rnr- 'lrLilf �R :.; i' �1:' .� •�"!:r ;1.: 12/24/2007 8:50:46 AM •n v ......, .,:...- .. +n .v... . 7':: sir•.narYnwi.��:fereiSl+',niFVrte 1:n r a. 150 Thom Hill Dr. - P.O. 788 dole, Pa 15095 �V Ir (7 2A) 7757 .w� 4 r, ,.... .. - - .. .... ..: 1... .�. a ..•.,:. s ..0 .. .G .� i�;'.r, ...,... .....— ��- ......, .- ..�..�: .._ ......�_ ....... SUSPENDED CEILING SYSTEM PREFAB. CEILING BEAM SALES AREA 3 5/B' X 18 GA. MT TRACK, TYP. FASTENED SECURELY ATTACHED TO TOP CHORD OF BAR JOIST DIAGONAL WALL BRACE SEE DETAIL C /A.2.5d 35 /8 "X18 GA. CC — METAL STUD FRAMING 0 16" O.C., TYP. 35 /8"X18GA. MT TRACK, TYP. 2 - #8 SCREWS EACH STUD (TYP) IF REQ'D, BY LANDLORD OR BUILDING DEPT. - G.C. TO EXTEND DRYWALL TO UNDERSIDE OF DECK ABOVE AND FIRESEAL NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY 4-IAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. AERIE Southcenter Moll Tukwila WA STOREFRONT SCTIONS Spy # 2120 3 5/8" X 18 GA. CC DIA. STUD BRACE SIMILAR TO DETAIL D /A.2.5d --� 1_ I_ 1_ I _ 1_l_1_I_I_. WNW! _1_1 wawa _1_1 _1_1 _1_l _1_l _1_1_1_1 _1_/_I_J•••. _1_1_1_•_ WWI 01_ 11 _._1_ 1_J NOTE: MALL BULKHEAD SHOWN IS FOR SCHEMATIC PURPOSES ONLY. ALWAYS BUILD STOREFRONT CONSTRUCTION TO ACTUAL LEASE LINE. VERIFY WITH MALL MANAGEMENT PRIOR TO START OF ANY WORK. MORTAR BED BY G.G. 518" TYPE 'X' DRYWALL FIELD FINISHED FIELD FINISHED WOOD PANELS ! WOOD PANELS CWD -3a] (TYP.) I CWD -4a] (TYP.) 3 5/8" CC 18 GA. METAL STUD DIAGONAL BRACING 0 4' -0" D.G. - ATTACH BRACE TO STRUCTURE ABOVE SEE DETAIL C /A.2.5d SECTION SCALE: 1 1/2" 1' - 0" PENDANT MOUNTED LIGHT FIXTURE ?REFINISHED GLAZING SYSTEM FURN. BY TENANT, INST. BY G.G. (DARK STAINED) [FC -2a] STOREFRONT FINISH NOTE: G.C. WILL FINISH ALL MILLWORK COMPONENTS WITH MILLWORKER SUPPLIED FINISHES IN STEPS AS FOLLOWS: 1) SAND AND FILL ALL MILLWORK COMPONENTS WITH 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL 12C51^1 9032 - ALLOW 1 -1/2 HOUR DRYING TIME. 3) SAND WITH 220 GRIT SANDPAPER. WIPE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISH - PRATT $ LAMBERT HIGH GLOSS 2319 - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH 500 GRIT SANDPAPER. WIPE WITH TACK RAG. 6) BRUSH OR ROLL ON DULL FINISH - PRATT $ LAMBERT DULL 2.319 VARS ARIES MIN. REQ'D. MALL CEILING MALL BULKHEAD MALL LIGHT COVE BRICK SOLDIER COURSE [BR -la] (TYP.) BRICK CBR -Ia] (TYP.) DRYWALL CP -3a] (TYP) SIGN K BRICK [BR -10] (TYP.) [FC -2a] MALL FINISHED FLOOR LEASE LINE GLASS TILES FURN. BY TENANT INST. BY G.G. (TILES SHALL BE BUTTED TIGHT WITH NO GROUTING AND NO THIN SET SHOWING) FLUORESCENT LIGHT FIXTURE FURN. BY TENANT, INST. BY G.C. SCONCE LIGHT FIXTURE - FURN. BY TENANT, INST. BY G.C. (TYP) ?REFINISHED DECORATIVE POST (TYP) (DARK STAINED) CUSTOM BENCH BY TENANT, INST. BY G.C. 1/4" THICK ALUMINUM ANGLE TRANSITION STRIP 10 SIGN FURNISHED BY SIGN CONSULTANT - INSTALLED BY G.C.SEE SHEET 'A.2.12' FOR MORE INFORMATION. ems' NOTE: LANDLORD'S BULKHEAD CONSTRUCTION INCLUDING BUT NOT LIMITED TO, SOFFIT, DUCTWORK, PIPING, LATERAL STRUCTURAL BRIDGING, ROOF DECK ETC. SHALL NOT BE USED TO SUPPORT TENANT'S STOREFRONT. G.C. SHALL DIAGONALLY BRACE STOREFRONT FRAMING TO BUILDING STRUCTURE WITH 3 5/8 "x 20 GA. METAL STUDS AT 4B' O.G. iar NOTE: IF REQUIRED BY LANDLORD OR BUILDING DEPARTMENT, G.C. SHALL FURNISH AND INSTALL 5 /B' TYPE 'X' FIRECODE DRYWALL TO STRUCTURE ABOVE AND FIRE SEAL FOR A ONE HOUR RATING. itar NOTE: REGARDING GLAZING STOP ATTACHMENT: G.C. SHALL FASTEN WOOD GLAZING STOPS WITH #8 SCREWS 0 12" O.C. WITH 5/8" MIN. EMBEDED TYP. . 12/24/2007 8:50:51 AM •.; :Y !;; ,; u:xtr. . :ass:..- :,: STOREFRONT SECTIONS AERIE Southcenter Moll Tukwila NA Space # 2120 1 KE h TH L�BUTTS, ARCHITECT 88999 -4�� 91307 AMERICAN EAGLE OUTFITTERS 150 Than Hill Dr. - P.O. 788 Warrendale, Ps. 15095 (724) 776 -4857 ._w ..... ,. ,_ ...,.._:..,., ,... ,.. - . , ........., .. ... .::._..,, .....::...,� is. mom:. F..:.- - =.. ,. .s;:F: II " -6" A.M.F. (MOLD) 11 -0" A.F.F. SUSPENDED CEILING SYSTEM WOOD TRIM CWD -Ia] EP-3a] (TYP.) 10 -0 3/4" A.M.F. (HOLD) DRYWALL CP -4a] (TYP) SALES AREA 4 #8 SCREWS (TYPICAL) 3 5/8" X 16 GA. MT TRACK, TYP. . • . • 'EE 'A,0>2 'FOR GRID 'SIZE 4. 0 3 #8 SCREWS (TYPICAL) TOP OF DISPLAY WINDOW PLATFORM BEYOND CFC -7a] CP-6a] (TYP) I/ / /lilIrlr / /Irlrl�/Irr/r /I 1'1�r.4. s1►1''\�►111 bassawais s �rlrJr�rJrlrire. I Il/II1IllffIPIi WOOD PANELS CWD -3a] CP -1a3 (TYP.) 3 BA" X 18 GA. MT TRACK, TYP. FASTENED SECURELY ATTACI -1ED TO TOP CHORD OF BAR JOIST DIAGONAL WALL BRACE SEE DETAIL C /A.2.54 3 5/8" X 18 GA. CC METAL STUD FRAMING g 16" O.C., TYP. 3 5/8" X I B GA. MT TRACK, TYP. IF REQ'D. BY LANDLORD OR BUILDING DEPT. - G.G. TO EXTEND DRYWALL TO UNDERSIDE OF DECK ABOVE AND FIRESEAL NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT. LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. DOUBLE. b ". 116, 'GA., •. ', .I IETAL'•STUD • • HEADER' • • SIrE Dl;i'AIL ' • A/A.2.5d • 3 5 /8 "X18 GA. CC DIA. STUD BRACE SIMILAR TO DETAIL D /A.2.5d --�, NOTE: MALL BULKHEAD SHOWN IS FOR SCHEMATIC PURPOSES ONLY. ALWAYS BUILD STOREFRONT CONSTRUCTION TO ACTUAL LEASE LINE. VERIFY WITH MALL MANAGEMENT PRIOR TO START OF ANY WORK. 3 5/8" CC 18 GA. METAL STUD DIAGONAL BRACING 0 4' -0" O,C. - ATTACH BRACE TO STRUCTURE ABOVE SEE DETAIL C /A,2.5d (SIM.) GRAPHIC DISPLAY GRID SYSTEM FURN. BY TENANT, INST. BY G.C. SEE DETAIL BB /A.0.2 SURFACE MTD. LIGHT TRACK FIXTURE - FURN. BY TENANT, INST. BY E.C. 7/8 "X7/6" PRESTAINED WOOD TRIM DOUBLE 6" 16 GA. METAL STUD HEADER (TYP.) SEE DETAIL A /A.2.5d OPEN TO DISPLAY WINDOW BEYOND SECTION TOP OF DISPLAY WINDOW PLATFORM CFC -7J CP -6a2 (TYP) SECURE TO CONC. SLAB WITH .145 I -1ILTI PIN 11/4" EMBEDMENT IN CONCRETE SLAB ! 32" O.C. ICBO # 2388 STOREFRONT FINISH NOTE: G.C. WILL FINISH ALL MILLWORK COMPONENTS WITH MILLWORKER SUPPLIED FINISHES IN STEPS AS FOLLOWS: i) SAND AND FILL ALL MILLWORK COMPONENTS WITH 220 GRIT SANDPAPER AND WHITE LATEX CAULK. 2) BRUSH OR ROLL ON WHITEWASH - M.L. CAMBELL 12CSN 9032 - ALLOW 1 -1/2 HOUR DRYING TIME. 3) SAND WITH 220 GRIT SANDPAPER. WIPE WITH TACK RAG. 4) BRUSH OR ROLL ON HIGH GLOSS VARNISI -1 - PRATT $ LAMBERT HIGH GLOSS Z3q - ALLOW 4 HOUR DRYING TIME. 5) SAND WITH 300 GRIT SANDPAPER. WIPE WITH TACK RAG. 6) SRUSH OR ROLL ON DULL FINISH - PRATT # LAMBERT DULL Z3q MALL CEILING MALL BULKHEAD MALL LIGHT COVE BRICK SOLDIER COURSE CBR -la] (TYP.) BRICK CBR -Ia] (TYP.) LEASE LINE FIELD FINISHED WOOD TRIM CND -1J (TYP.) LEASE LINE GLASS TILES FURN. BY TENANT INST. BY G.C. (TILES S1 -IALL BE BUTTED TIGHT WITH NO GROUTING AND NO THIN SET SHOWING) 10" -0" ABOVE MALL FLOOR FLUORESCENT LIGHT FIXTURE FURN. BY TENANT, INST. BY G.C. SCONCE LIGHT FIXTURE - FURN. BY TENANT, INST. BY G.C. (TYP) PREPINISHED GLAZING SYSTEM FURN. BY TENANT, INST. BY G.G. (DARK STAINED) 1 /2" TEMPERED PLATE GLASS PREFINISHED DECORATIVE POST (TYP) (DARK STAINED) BRICK CBR -1a3 (TYP.) CFC -2a] 1 /4" THICK ALUMINUM ANGLE TRANSITION STRIP MALL FINISHED FLOOR (IO ) SIGN FURNISI -IED BY SIGN CONSULTANT - INSTALLED BY G.C.SEE SHEET 'A.2.12' FOR MORE INFORMATION. rir NOTE' LANDLORD'S BULKHEAD CONSTRUCTION INCLUDING BUT NOT LIMITED TO, SOFFIT, DUCTWORK, PIPING, LATERAL STRUCTURAL BRIDGING, ROOF DECK ETC. SHALL NOT BE USED TO SUPPORT TENANT'S STOREFRONT. G.C. SHALL DIAGONALLY BRACE STOREFRONT FRAMING TO BUILDING STRUCTURE WITH 3 5 /8'x 20 GA. METAL STUDS AT 48" O.C. gar NOTE: IF REQUIRED BY LANDLORD OR BUILDING DEPARTMENT, G.G. SHALL FURNISH AND INSTALL 5/6" TYPE 'X' FIRECODE DRYWALL TO STRUCTURE ABOVE AND FIRE SEAL FOR A ONE HOUR RATING. gar NOTE: REGARDING GLAZING STOP ATTACHMENT: G.C. SHALL FASTEN WOOD GLAZING STOPS WITH #8 SCREWS 0 12" O.G. WITH 516" MIN. EMBEDED (TYP. AREERICAN EAGLE 12/24/2007 B :50:56 AM • 10' -6" A.M.F. HOLD 10' -0" A.F.F. WOOD TRIM CND -1a] CP -3a] (TYP.) DRYWALL CP -4a] (TYP) #8 SCREWS XI2" O.C. EACH SIDE DOUBLE METAL STUD POST POST TO BE 6" 16 GA. CC STUD TYPICAL DOUBLE STUD POST DETAIL SCALE: 6" = 1' -0" PLAN VIEW DBL. 6" - 16 GA. (MIN.) CC PROFILE STEEL STUDS, COPE FLANGES I STUD COLUMN SEE DETAIL A/A.2.5d (4) #8 SCREWS 5/8" TYPE 'X' DRYWALL CP -3a] OVER 3/4 F.R.T. PLYWOOD 2.5d 3 '0 9 -0 3/4" A.M.F. (HOLD) 1/2" TEMPERED PLATE GLASS V SECTION SECT SCALE: 1 1/211 1 1 _ 0 1! 5 :1 a 16 GA. MT TRACK EACH SIDE DBL. 3 5/8" - 16 GA. CC STEEL STUDS - SEE SHEET A.2.4 LOCATE DIAGONAL STUDS BRACE 0 EA. SEAM/ COLUMN INTERSECTION. SEE DETAIL C /A.2.5d (6) #8 SCREWS EACH SIDE DBL. 3 5/8" - 16 GA. (MIN.) CC PROFILE STEEL STUD POST LTA X 2 1/2" LONG CLIP ANGLE (I) 3/8" 0 HILT! KWIK BOLT 11 IN EXISTING CONCRETE FLOOR W/ 2 1/2" EM13ED 2 SIDES MIN. D 2 1/2" X 18 GA. CC METAL STUD FRAMING gi 16" O.C., TYP. PREFINISHED GLAZING SYSTEM FURN. BY TENANT, INST. BY G.C. (DARK STAINED) SCALE: 1 I /2" = 11 - O" METAL STUDS P1643 ADJUST BRACE W/ 1/2" BOLT $ WASHER FIELD FINISHED WOOD PANELS [WD -1a] (SEE NOTE THIS SHEET) HEADER BRACE DETAI NOT TO SCALE 152 A 1 1 1 1/2 MAX. 1 MIN 3 5/8" x 16 GA CC METAL STUD BRACE 0 4' -O" O.C. MAX. (UNO) (12' -0" MAX_ LENGTH) COPE FLANGES AND BEND WEB TO HEADER W/3 08 SCREWS MIN. HEAD DIA. 5/16" DSL. 6" - 16 GA. (MIN.) STEEL STUDS HEADER SEE DETAIL A/A.2.54 VERIFY SIZE AND LOCATION OF EXIST. STRUCTURE ETAL NOT TO SCALE 3 RACE A 2 AS . PER WALL FIELD FINISHED WOOD FIELD FINISHED WOOD VARIES - COORDINATE WITH PLAN SECTION SEE SHEET 'A.2.4 L' _ t c PARTIAL SECTION PENDANT MOUNTED LIGHT FIXTURE 3 5/8" X 18 GA. CC METAL STUD FRAMING 16" O.C., TIP. PREFINISI -IED GLAZING SYSTEM FU . BY TENANT, INST. BY G.C. (DARK STAINED) FIELD FINISHED WOOD PANELS [ND -103 (SEE NOTE THIS SHEET) 1/2 ". TgMPERE T .'PLATE , GLAS r 5/8 TYPE 'X' DRYWALL CP -3a] OVER 3/4" F.R.T. PLYWOOD o6%-o55' Wstfiek[ Working Drawing gt Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for intent only. All actual field conditions are requ! �T CENTER verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir• • to be kept on the Si.ned Review RECEIVED CITY OF TUK WILA FEB 0 4 ?008 job "e at aur2/28/o7 Date NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE SEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 0 0 N 2 75 1 4 0 CNI 8 2 -* SCRF3^1S (TYR.) DIAGONAL 1 LOCATE BR 20' -0" O.C. DIAGONALS SHOWN MIN LENGTH OF • 10' -6" A.M.F. HOLD 10' -0" A.F.F. WOOD TRIM CND -1a] CP -3a] (TYP.) DRYWALL CP -4a] (TYP) #8 SCREWS XI2" O.C. EACH SIDE DOUBLE METAL STUD POST POST TO BE 6" 16 GA. CC STUD TYPICAL DOUBLE STUD POST DETAIL SCALE: 6" = 1' -0" PLAN VIEW DBL. 6" - 16 GA. (MIN.) CC PROFILE STEEL STUDS, COPE FLANGES I STUD COLUMN SEE DETAIL A/A.2.5d (4) #8 SCREWS 5/8" TYPE 'X' DRYWALL CP -3a] OVER 3/4 F.R.T. PLYWOOD 2.5d 3 '0 9 -0 3/4" A.M.F. (HOLD) 1/2" TEMPERED PLATE GLASS V SECTION SECT SCALE: 1 1/211 1 1 _ 0 1! 5 :1 a 16 GA. MT TRACK EACH SIDE DBL. 3 5/8" - 16 GA. CC STEEL STUDS - SEE SHEET A.2.4 LOCATE DIAGONAL STUDS BRACE 0 EA. SEAM/ COLUMN INTERSECTION. SEE DETAIL C /A.2.5d (6) #8 SCREWS EACH SIDE DBL. 3 5/8" - 16 GA. (MIN.) CC PROFILE STEEL STUD POST LTA X 2 1/2" LONG CLIP ANGLE (I) 3/8" 0 HILT! KWIK BOLT 11 IN EXISTING CONCRETE FLOOR W/ 2 1/2" EM13ED 2 SIDES MIN. D 2 1/2" X 18 GA. CC METAL STUD FRAMING gi 16" O.C., TYP. PREFINISHED GLAZING SYSTEM FURN. BY TENANT, INST. BY G.C. (DARK STAINED) SCALE: 1 I /2" = 11 - O" METAL STUDS P1643 ADJUST BRACE W/ 1/2" BOLT $ WASHER FIELD FINISHED WOOD PANELS [WD -1a] (SEE NOTE THIS SHEET) HEADER BRACE DETAI NOT TO SCALE 152 A 1 1 1 1/2 MAX. 1 MIN 3 5/8" x 16 GA CC METAL STUD BRACE 0 4' -O" O.C. MAX. (UNO) (12' -0" MAX_ LENGTH) COPE FLANGES AND BEND WEB TO HEADER W/3 08 SCREWS MIN. HEAD DIA. 5/16" DSL. 6" - 16 GA. (MIN.) STEEL STUDS HEADER SEE DETAIL A/A.2.54 VERIFY SIZE AND LOCATION OF EXIST. STRUCTURE ETAL NOT TO SCALE 3 RACE A 2 AS . PER WALL FIELD FINISHED WOOD FIELD FINISHED WOOD VARIES - COORDINATE WITH PLAN SECTION SEE SHEET 'A.2.4 L' _ t c PARTIAL SECTION PENDANT MOUNTED LIGHT FIXTURE 3 5/8" X 18 GA. CC METAL STUD FRAMING 16" O.C., TIP. PREFINISI -IED GLAZING SYSTEM FU . BY TENANT, INST. BY G.C. (DARK STAINED) FIELD FINISHED WOOD PANELS [ND -103 (SEE NOTE THIS SHEET) 1/2 ". TgMPERE T .'PLATE , GLAS r 5/8 TYPE 'X' DRYWALL CP -3a] OVER 3/4" F.R.T. PLYWOOD o6%-o55' Wstfiek[ Working Drawing gt Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for intent only. All actual field conditions are requ! �T CENTER verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir• • to be kept on the Si.ned Review RECEIVED CITY OF TUK WILA FEB 0 4 ?008 job "e at aur2/28/o7 Date NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE SEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 0 0 N 2 75 1 4 0 CNI 8 LEASE LINE A.F.F. CONCEALED SLOTTED STANDARDS 0— FINISHED 2' -0" O.C. MTD. 6" A.F.F. (TYP.) SIM. II' -0" A.F.F. ' A.F.F. MALL DRYWALL CP -4a] (TYP) [B -2a] CP -Ia] (TYP.) CB -la] CP -la] (TYP.) A A.2.6 11' -0" A.F.F. Sl -6" A.F.F. c A.2.6 PREFAB. CEILING BEAM ASSEMBLY CP -4a] (TYP.) FLOOR LINE RIGHT SIDE ELEVATION SCALE: I /4" 1 - 0" [15-20] CP -103 (TYP.) [B -la] CP -103 (TYP.) tWD -I03 CP -30] (TYP.) FINISHED FLOOR LINE DRYWALL CP -4] (TYP) SCALE: I /4" p 1 - 0" — SUSPENDED CEILING SYSTEM PREFAB. 'FAUX' DISPLAY CASE - SEE DET. A/A.2.II LEFT SIDE ELEVATION SUSPENDED CEILING CWD -l01 CP -303 PREFAB_ CEILING SYSTEM (T BEAM ASSEMBLY CP -4a] (TYP.) FINISHED FLOOR LINE SCALE: 1/4" I ' — 0 •• REAR ELEVATION CONCEALED SLOTTED STANDARDS 0 2 -0 O.C. rill). Q 6" A.F.F. (TYP.) !J. RE -SAWN WOOD CEILING AND BOX BEAM ASSEMBLY CP -30] (TYP.) DRYWALL CP -4a] (TYP) PREFAB. CEILING BEAM ASSEMBLY CP -443 (TYP.) DRAPERY * DRAPERY ROD BY TENANT, INST. EY G.C. SEE DET. AA /A.2.6 (TYP -) 1 1 1 OPENING TO VESTIBULE BEYOND PREFAB. ''CASH /WRAP" CASEWORK COMPONENTS (TYP.) SEE DETAILS ON SHEET F.2.5 PREFABRICATED "LEANING" MIRROR FURN. BY TENANT, INST. BY G.C. RE -SAWN 1 X 10 WOOD TRIM @ PERIMETER CP -50] DRYWALL CP -4a3 (TYP) LEASE LINE DEMISING PARTITION PREFAB. CEILING BEAM ASSEMBLY CP -443 (TYP.) RE -SAWN I X 10 WOOD TRIM 0 PERIMETER CP -3a3 RE -SAWN WOOD CEILING AND BOX BEAM ASSEMBLY CP -30] (TYP.) CB -20] CP -1a3 (TYP.) CB-103 CP -la] (TYP.) DRYWALL CP-40] (TYP) PREFAB. CORNER "DAYBED" CASEWORK COMPONENTS. SEE DETAILS ON SHEET 'F.2.3' SUSPENDED CEILING — SYSTEM DRYWALL CP -4a1 (TYP) CWD -10] CP -303 (TYP.) ARMOIRE FURNISHED BY TENANT, PLACED BY G.C. WALL TRIM - SEE DET. L/A.2.8 (TYP.) CONCEALED SLOTTED STANDARDS 0 2 -0" O.C. MD. 0 6" A.F.F. (TYP.) NO SCALE 11 -0" A.F.F. 81 -61' A.F.F. PREFAB. CEILING BEAM ASSEMBLY CP -30] (TYP.) • A.2.5 SIM. LEASE LINE MALL OPENING TO VESTIBULE BEYOND PARTIAL ELEVATION KEY STOCK PARTITION A A.2.6 SCALE: NTS DRAPERY DETAIL KEY NOTES: SIGN - FURNISHED BY SIGN CONSULTANT, INSTALLED BY G.G. SEE SHEET 'A.2.I2' FOR MORE INFORMATION. NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM WALL PRIOR TO PAINTING MDF PANEL INSTALLATION INSTRUCTIONS: 1. EACH PANEL SHALL BE FASTENED TO THE METAL STUDS VERTICALLY AT FOUR EQUALLY SPACED LOCATIONS ALONG EACH PANEL SIDE (OR METAL STUD IF PANEL I5 GREATER THAN 2' -0' IN WIDTH). EACH LOCATION MUST FIRST BE PREPARED BY DRILLING A MINIMUM 3/3' DIAMETER COUNTERSUNK HOLE TO RECEIVE THE FASTENER. THE PANEL SHALL BE FIRMLY SECURED AT EACH HOLE LOCATION VIA I -I /4" SELF - TAPPING SCREWS. INSTALL MORE FASTENERS AS REQUIRED TO EVENLY AND NEATLY SECURE THE MDF PANEL TO THE METAL STUD. EACH FASTENING LOCATION MUST FIRST BE PREPARED BY DRILLING A MINIMUM 3/6" DIAMETER COUNTERSUNK DOLE PRIOR TO DRIVING THE 1 -1/4' SELF - TAPPING SCREW TO ENSURE THAT THE SCREW HEAD SITS I/8" BELOW THE FACE OF THE MDF PANEL. THE TOP AND BOTTOM SCREWS ARE NOT REQUIRED TO BE COUNTERSUNK IF THEY WILL BE FULLY CONCEALED BY WOOD TRIM. 2. FILL EACH EXPOSED HOLE WITH A SANDABLE, NON- SHRINKING, PAINTABLE WOOD FILL COMPOUND (NO LATEX CAULK, DRYWALL COMPOUND, OR PAINTER'S PUTTY). THE USE OF ANY HIGH - MOISTURE CONTENT COMPOUND I5 NOT APPROVED AND WILL CAUSE THE MDF PANEL TO SWELL, WHICH WILL REQUIRE ADDITIONAL ATTENTION TO REPAIR THE EFFECTED AREA BEFORE PROCEEDING. 3. AFTER FIRST APPLICATION DRIES, SAND FLUSH, DUST AWAY LOOSE MATERIAL AND RE -APPLY A SECOND SKIM COAT. A. AFTER SECOND APPLICATION DRIES, FINISH SANDING AREA 1/41114 AN ORBITAL PALM SANDER (NO BLOCK SANDING BY NAND). 5. EVENLY PRIME ALL HOLES WITH SNERWIN WILLIAMS PREPRITE PRCBLOCK WHITE SPRAY PRIMER (NO MATERIAL RUNS). PRIMER MUST SE COMPLETELY DRY BEFORE PROCEEDING OR PAINT ADHESION PROBLEMS WILL ARISE DURING FINISHING. 6. FINISH ENTIRE PANEL. WITH SPECIFIED PAINT AS DIRECTED IN 114E FINISH SCHEDULE. Si. o yesu w Y OF TUKWILA Working Drawing Rfali 4 L; .it Approved Approved as Noted PERMIT CENTER ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir- . to . _ be kept on the job site s'e et aT2/28/07 Date NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY 'OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. rifr oz a „ szU" I an, 00 V 9 0 4 Lti Lu CZ 0 7 � L { a 1.4 <4300 min ur444 w.0,11 n b C4 n St°141c° 51 Drawing No. A.2.6 Ys DRYWALL CP -40] (TYP) LEASE LINE DEMISING PARTITION 0II' -0" A.F.F DRYWALL CP -4a] (TYP) SUSPENDED CEILING CWD -Ia] CP -3a] SYSTEM (TYP.) A.2.6a CWD -1a] CP -30] (TYP.) A.2.6a SCALE: 1/4" n 1' - 0" INTERIOR ELEVATION SCALE: 1/4" 1' - 0" SUSPENDED CEILING SYSTEM PREFAB_ CEILING DRYWALL CP -44 BEAM ASSEMBLY (TYP) CP -44] (TYP.) INTERIOR ELEVATION 1' -101" :1 -1 OF VANITY RE - SAWN 1 X 10 WOOD TRIM 6 PERIMETER [P -3a] FINISHED — FLOOR LINE 18 "" STANDARD FITTING VANITY FURNISHED ROOM POUF. FURNISHED BY TENANT, BY TENANT, INST. BY G.C. PLACED BY G.C. INTERIOR ELEVATION PREFAB_ CEILING BEAM ASSEMBLY CP -44] (TYP.) SUSPENDED CEILING SYSTEM PREFABRICATED "LEANING" MIRROR FURN_ BY TENANT, INST. BY G.C. EiL DRYWALL [P-4c0 (TYP) FINISHED FLOOR LINE DOUBLE BRICK COLUMN (BR -1a) SEE DETAILS AA/A.2.6 AND BB /A.2.6 q' -6" A.F.F. CWD -10a] CP -la] 11' -0" A.F.F. A.F.F. WALL TRIM - SEE DET. L/A.2.8 (TYP.) CONCEALED SLATTED STANDARDS 2' -0" o.C. MTD. 6 6" A.F.F. (TYP.) LEASE LINE DEMISING PARTITION LEASE LINE DEMISING PARTITION DRYWALL CP -403 MP) WALL TRIM - SEE DET. L/A.2.6 (TYP.) SCALE: 1/4" = 1' - 0" PREFAB. CEILING BEAM ASSEMBLY CP -4a3 (TYP.) PREFAB_ CORNER "DAYBED" CASEWORK COMPONENTS. SEE DETAILS ON SHEET I F .2.3' A.2.6a DRYWALL CP -40] (TYP) LEASE LINE DEMISING PARTITION CONCEALED SLOTTED STANDARDS 2' -O" O.C. MTD. 6" A.F.F. (TYP.) SUSPENDED CEILING SYSTEM INTERIOR ELEVATION RE -SAWN 1 X 10 WOOD DRYWALL CP -40] TRIM CP PERIMETER OF (TYP) THIS ROOM ONLY [P -3a] IS "" STANDARD FITTING ROOM POUF. FURNISHED BY TENANT, INST. BY G.C. FINISHED — FLOOR LINE PREFAB. CEILING BEAM ASSEMBLY CP -40] (TYP.) DRYWALL CP -4a] (TYP) DOUBLE BRICK COLUMN (BR -Ia) SEE DETAILS AA/A.2.8 AND BB /A.2.8 11 = DRYWALL CP -4a] (NP) END-la] EP-3a] (TYP.) STOCKROOM PARTITION A.2.6a SUSPENDED CEILING SYSTEM 4' -0" X 2' -0" H.C. FITT ROOM POUF. FURNISHED TENANT, INST. 8Y G.G. - DETAILS ON SHEET 'A A.2.6a 11' -0 A.F.F. q' -6" A.F.F. s B' -0" A.F_F. 4 SUSPENDED CEILING CWD -la] EP -3a] SYSTEM (TYP. ) FINISHED FLOOR LINE SCALE: 1/4" 1' - 0" INTERIOR ELEVATION INTERIOR ELEVATION DRYWALL CP-40] () ING BY SEE .2.q' LEASE LINE DEMISING PARTITION -2a] LP -10] (T(P.) LEASE LINE (10.) NOTES: SIGN - FURNISHED BY SIGN CONSULTANT, INSTALLED BY G.C. SEE SHEET 'A.2.12' FOR MORE INFORMATION. ROIL PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM * WALL PRIOR TO PAINTING MDF PANEL INSTALLATION INSTRUCTIONS: 1. EACH PANEL SHALL BE FASTENED TO THE METAL STUDS VERTICALLY AT FOUR EQUALLY SPACED LOCATIONS ALONG EACH PANEL SIDE (OR METAL STUD IF PANEL 15 GREATER THAN 2' -0' IN WIDTH). EACH LOCATION MUST FIRST BE PREPARED BY DRILLING A MINIMUM 3/8" DIAMETER COUNTERSUNK 1-10LE TO RECEIVE THE FASTENER. THE PANEL SHALL BE FIRMLY SECURED AT EACH HOLE LOCATION VIA I -I/4" SELF- TAPPING SCREWS. INSTALL MORE FASTENERS AS REQUIRED TO EVENLY AND NEATLY SECURE THE MDF PANEL TO THE METAL STUD. EACH FASTENING LOCATION MUST FIRST BE PREPARED BY DRILLING A MINIMUM 3/8" DIAMETER COUNTERSUNK HOLE PRIOR TO DRIVING THE 1 -1 /4" SELF- TAPPING SCREW TO ENSURE THAT THE SCREW HEAD SITS I/S' BELOW THE FACE OF THE MDF PANEL. THE TOP AND BOTTOM SCREWS ARE NOT REQUIRED TO BE COUNTERSUNK IF THEY WILL BE FULLY CONCEALED BY WOOD TRIM. 2. FILL EACH EXPOSED HOLE WITH A SANDABLE, NON - SHRINKING, PAINTABLE WOOD FILL COMPOUND (NO LATEX CAULK, DRYWALL COMPOUND, OR PAINTER'S PUTTY). THE USE OF ANY HIGH - MOISTURE CONTENT COMPOUND I5 NOT APPROVED AND WILL CAUSE THE MDF PANEL TO SWELL, WHICH WILL REQUIRE ADDITIONAL ATTENTION TO REPAIR THE EFFECTED AREA BEFORE PROCEEDING. 3. AFTER FIRST APPLICATION DRIES, SAND FLUSH, DUST AWAY LOOSE MATERIAL AND RE -APPLY A SECOND SKIM COAT. 4. AFTER SECOND APPLICATION DRIES, FINISH SANDING AREA WITH AN ORBITAL PALM SANDER (NO BLOCK SANDING BY HAND). 5. EVENLY PRIME ALL HOLES WITH SHERWIN WILLIAMS PREPRITE PROBLOCK WHITE SPRAY PRIMER (NO MATERIAL RUNS). PRIMER MUST BE COMPL..ETELY DRY BEFORE PROCEEDING OR PAINT ADHESION PROBLEMS WILL ARISE DURING FINISHING. 6. FINISH ENTIRE PANEL WITH SPECIFIED PAINT AS DIRECTED IN THE FINISH SCHEDULE. RECEIVED CITY OF TUKWIL4 FEB 0 4 2008 MIT CENTER est ie Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all govemment regulations. One (1) copy of this landlord stamped set of drawings is requir= . to be kept on the r S1•ned Date NO E: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. z 0 LU l-rE -- O z IMMO MEE ZIIIIIIMMOSZIRIERERIENSIESSEIdi l a _ WINIA• ∎4 WALL CONSTRUCTION DETAIL @ CASWWRAP !-HALF FULL SIZE 5/8" DRYWALL CP -30] = (TYP) METAL STUD FRAMING AS REQUIRED (TYP) NOTE: CEILING CONDITIONS ABOVE VALANCE VARY - COORDINATE WITH PLANS AS REQUIRED. 3 l'g II PLYWOOD FASTENED TO INSIDE OF METAL STUD - FURN. $ INST. BY G.C. rs FACE OF DEMISING WALL OR ADJACENT PARTITION. SEE FLOOR PLAN FOR LOCATION LIGHT FIXTURE - FURNISHED BY TENANT - INSTALLED BY E.C. 5/8" DRYWALL CP -4a] (r'P) 9' -6" A.F.F. 5/8" MDF [WD -2a] [P -1a] AT REAR OF DISPLAY BAY 5/8" DRYWALL CP -4a] (TYP) CB -la] EP-1a3 (TYP) CB -2a] CP -Ia] (TYP) FINISHED FLOOR PARTIAL SECTION THOU GH DRYWALL VALANCE CASE SLOTTED INSERTS CL. OF SLOT HALF FULL SIZE OF STANDAR FACE OF DEMISING WALL OR (MIN) " ADJACENT PARTITION. SEE FLOOR PLAN FOR LOCATION CONCEALED SLOTTED STANDARD DETAIL END -Ia] DRYWAL (TYP) WOOD TF SEE DET (TYP) CHA DRY (Tr PREFAB. 9' -6" A.F.F. .. .:. "- " �.. "• " �..�• " �..�• " �.. "- " �.. "• " .. " � . -" " �.."" ... .. ..,:., :. AILL/A.2.8 � � .� .� � "•." _� �.•. "� "� �.�." "� �.•." .� �.•.� "� �.•. "� " � �. "." "� �. ".' -.- �_�. " - "" •. • � -." •_�. �.� �_�. ." -. S' - 6" A.F.F. 8' - 0" A.F.F. . "�.�" ".' .�� "_� .�" "_' .�� "_• .�� "_� .�� "_• .�� "," .�� ".�.. "�' "�.. "�' "�.. "�'.�.. "� ".�.. "• ".�.. " "' FRONT OF STORE MFERED CORNER BY .. . WALL INSTALLER �a . PREFAB. ROOM DIVIDER BY - MILLWORK SUPPLIER WITH %" DRYWALL CLADDING BY G.C. [P -4a] WALL PANEL (TYPE VARIES) [P -Ia] OF SLOT METAL INSERT ADAPTOR FASTENED TO METAL STUDS EVERY 24" O.G. (MIN) NOTE: PROVIDE EXTRA SUSPENSION WIRES AT BEAM /ARCH LOCATIONS NOTE: G.C. SHALL INSURE THAT SLOTTED INSERTS ARE PLUMS AND LEVEL WITH ADJACENT INSERTS PRIOR TO FASTENING CONCEALED SLOTTED STANDARD DETAIL HALF FULL SIZE ft_ OF SLOT SLOTTED INSERTS FACE OF DEMISING WALL OR ADJACENT PARTITION. SEE (MIN) " FLOOR PLAN FOR LOCATION �i. OF STANDAR ROOM DIVIDER /ARCH ELEVATION WALL PANEL (TYPE VARIES) CP -1a] METAL INSERT ADAPTOR FASTENED TO METAL STUDS EVERY 24" O.C. (MIN) C3-10] EP- 1a3 (') [B -2a] CP -10] (TYP) FINISHED FLOOR LINE RE -SAWN WOOD CEILING $ BOX BEAM ASSEMBLY CP -3a7. SEE SHEET 'A.2.8' FOR DETAILS. "."-- RE -SAWN 1 X 10 WOOD TRIM 0 PERIMETER OF THIS ROOM ONLY. SEE SHEET 'A.0.2' FOR MORE INFORMATION [P -3a] PREFAB. ARCH ASSEMBLY CLAD WITH DRYWALL CP -5a] SEE ELEVATION ON SHEET 'A2.6' 2a] CP -1a] ) OF SLOT SLOTTED INSERTS HALF FULL SIZE 1211 X (MIN) RE -SAWN WOOD CEILING It BOX BEAM ASSEMBLY CP -3a3 . SEE SHEET 'A.2.8' FOR DETAILS. DRYWALL P-43 (TYP) CWD -2a] CP -10] (TYP) FINISHED FLOOR LINE qi OF STANDAR PREFAB. ROOM DIVIDER BY MILLWORK SUPPLIER WITH %' DRYWALL CLADDING BY G.G. CP -44] WALL PANEL (TYPE VARIES) CP -103 OF SLOT METAL INSERT ADAPTOR FASTENED TO METAL STUDS EVERY 24" O.C. (MIN) CONCEALED SLOTTED STANDARD DETAIL NOTE: PROVIDE EXTRA SUSPENSION WIRES AT BEAM /ARCH LOCATIONS KEY NOTES: CONCEALED WALL STANDARDS - INTEGRATED METAL STUD WITH SLOTTED STANDARD FURNISHED BY TENANT AND INSTALLED BY G.G. 0 6' A.F.F. SEE DETAILS G /A.2.7 $ 14/A.2.7 AND ELEVATIONS ON SHEET 'X2.6' FOR SIZE AND LOCATION. Wst/1e/[ NOTE: IF ALLOWED BY LOCAL CODES NONCOMBUSTIBLE WOOD CAN BE SUBSTITUTED FOR NAILERS $ BLOCKING NOTE: ALL PREFABRICATED COMPONENTS (PILASTERS, COLUMNS, VALANCES, CEILING BEAMS, NAILERS, ETC.) FURN. 5Y MILLWORK SUPPLIER, INSTALLED BY G.G. NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM 4 WALL PRIOR TO PAINTING. Working Drawing Review , Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant • is responsible for complying with all government regulations.. One (1) copy of this landlord stamped set of drawings is requir to be kept on the job site al a I t- r2/28,07 Si ned Date PREFABRICATED ROOM DIVIDER ELEVATION CWD -la] CP -34] () FRONT OF STORE CWD -20 EP-Ia] (TYP) C8 -Ia] EP-1a3 (TYP) [8 -2a] CP -la] 1 (TYP) NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. LI .....0 # 1111 = 11 11 - • • i$ fi.lii • IMMO MEE ZIIIIIIMMOSZIRIERERIENSIESSEIdi l a _ WINIA• ∎4 WALL CONSTRUCTION DETAIL @ CASWWRAP !-HALF FULL SIZE 5/8" DRYWALL CP -30] = (TYP) METAL STUD FRAMING AS REQUIRED (TYP) NOTE: CEILING CONDITIONS ABOVE VALANCE VARY - COORDINATE WITH PLANS AS REQUIRED. 3 l'g II PLYWOOD FASTENED TO INSIDE OF METAL STUD - FURN. $ INST. BY G.C. rs FACE OF DEMISING WALL OR ADJACENT PARTITION. SEE FLOOR PLAN FOR LOCATION LIGHT FIXTURE - FURNISHED BY TENANT - INSTALLED BY E.C. 5/8" DRYWALL CP -4a] (r'P) 9' -6" A.F.F. 5/8" MDF [WD -2a] [P -1a] AT REAR OF DISPLAY BAY 5/8" DRYWALL CP -4a] (TYP) CB -la] EP-1a3 (TYP) CB -2a] CP -Ia] (TYP) FINISHED FLOOR PARTIAL SECTION THOU GH DRYWALL VALANCE CASE SLOTTED INSERTS CL. OF SLOT HALF FULL SIZE OF STANDAR FACE OF DEMISING WALL OR (MIN) " ADJACENT PARTITION. SEE FLOOR PLAN FOR LOCATION CONCEALED SLOTTED STANDARD DETAIL END -Ia] DRYWAL (TYP) WOOD TF SEE DET (TYP) CHA DRY (Tr PREFAB. 9' -6" A.F.F. .. .:. "- " �.. "• " �..�• " �..�• " �.. "- " �.. "• " .. " � . -" " �.."" ... .. ..,:., :. AILL/A.2.8 � � .� .� � "•." _� �.•. "� "� �.�." "� �.•." .� �.•.� "� �.•. "� " � �. "." "� �. ".' -.- �_�. " - "" •. • � -." •_�. �.� �_�. ." -. S' - 6" A.F.F. 8' - 0" A.F.F. . "�.�" ".' .�� "_� .�" "_' .�� "_• .�� "_� .�� "_• .�� "," .�� ".�.. "�' "�.. "�' "�.. "�'.�.. "� ".�.. "• ".�.. " "' FRONT OF STORE MFERED CORNER BY .. . WALL INSTALLER �a . PREFAB. ROOM DIVIDER BY - MILLWORK SUPPLIER WITH %" DRYWALL CLADDING BY G.C. [P -4a] WALL PANEL (TYPE VARIES) [P -Ia] OF SLOT METAL INSERT ADAPTOR FASTENED TO METAL STUDS EVERY 24" O.G. (MIN) NOTE: PROVIDE EXTRA SUSPENSION WIRES AT BEAM /ARCH LOCATIONS NOTE: G.C. SHALL INSURE THAT SLOTTED INSERTS ARE PLUMS AND LEVEL WITH ADJACENT INSERTS PRIOR TO FASTENING CONCEALED SLOTTED STANDARD DETAIL HALF FULL SIZE ft_ OF SLOT SLOTTED INSERTS FACE OF DEMISING WALL OR ADJACENT PARTITION. SEE (MIN) " FLOOR PLAN FOR LOCATION �i. OF STANDAR ROOM DIVIDER /ARCH ELEVATION WALL PANEL (TYPE VARIES) CP -1a] METAL INSERT ADAPTOR FASTENED TO METAL STUDS EVERY 24" O.C. (MIN) C3-10] EP- 1a3 (') [B -2a] CP -10] (TYP) FINISHED FLOOR LINE RE -SAWN WOOD CEILING $ BOX BEAM ASSEMBLY CP -3a7. SEE SHEET 'A.2.8' FOR DETAILS. "."-- RE -SAWN 1 X 10 WOOD TRIM 0 PERIMETER OF THIS ROOM ONLY. SEE SHEET 'A.0.2' FOR MORE INFORMATION [P -3a] PREFAB. ARCH ASSEMBLY CLAD WITH DRYWALL CP -5a] SEE ELEVATION ON SHEET 'A2.6' 2a] CP -1a] ) OF SLOT SLOTTED INSERTS HALF FULL SIZE 1211 X (MIN) RE -SAWN WOOD CEILING It BOX BEAM ASSEMBLY CP -3a3 . SEE SHEET 'A.2.8' FOR DETAILS. DRYWALL P-43 (TYP) CWD -2a] CP -10] (TYP) FINISHED FLOOR LINE qi OF STANDAR PREFAB. ROOM DIVIDER BY MILLWORK SUPPLIER WITH %' DRYWALL CLADDING BY G.G. CP -44] WALL PANEL (TYPE VARIES) CP -103 OF SLOT METAL INSERT ADAPTOR FASTENED TO METAL STUDS EVERY 24" O.C. (MIN) CONCEALED SLOTTED STANDARD DETAIL NOTE: PROVIDE EXTRA SUSPENSION WIRES AT BEAM /ARCH LOCATIONS KEY NOTES: CONCEALED WALL STANDARDS - INTEGRATED METAL STUD WITH SLOTTED STANDARD FURNISHED BY TENANT AND INSTALLED BY G.G. 0 6' A.F.F. SEE DETAILS G /A.2.7 $ 14/A.2.7 AND ELEVATIONS ON SHEET 'X2.6' FOR SIZE AND LOCATION. Wst/1e/[ NOTE: IF ALLOWED BY LOCAL CODES NONCOMBUSTIBLE WOOD CAN BE SUBSTITUTED FOR NAILERS $ BLOCKING NOTE: ALL PREFABRICATED COMPONENTS (PILASTERS, COLUMNS, VALANCES, CEILING BEAMS, NAILERS, ETC.) FURN. 5Y MILLWORK SUPPLIER, INSTALLED BY G.G. NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM 4 WALL PRIOR TO PAINTING. Working Drawing Review , Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant • is responsible for complying with all government regulations.. One (1) copy of this landlord stamped set of drawings is requir to be kept on the job site al a I t- r2/28,07 Si ned Date PREFABRICATED ROOM DIVIDER ELEVATION CWD -la] CP -34] () FRONT OF STORE CWD -20 EP-Ia] (TYP) C8 -Ia] EP-1a3 (TYP) [8 -2a] CP -la] 1 (TYP) NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. CFC-ba3 TUCKED INTO 1/4' GROOVE 521..5. FELT PADDING CONTINUOUS 154* FELT PAPER BARRIER UNDER WOOD FLOOR OVER PLYWOOD NAILER A.2.7a CFC -101 OVER F. R .T. PLYWOOD NAILER A.2.7a — N. I _ V • _ t r 7 " CONTINUOUS 154* FELT PAPER BARRIER UNDER WOOD FLOOR OVER PLYWOOD NAILER TRANSITION IAIOOEVIAIOOD FLOOR SCALE: 3 . I I - 0 SEE FLOOR PLAN VARIES CONCRETE FLOOR SLAB VARIES 15nffaLY ift 1 2 11111 N .... 14 411 01".. -911111 -411 '9111114 SEE FLOOR PLAN VARIES CONCRETE FLOOR SLAB CONTINUOUS FIRE CARPET TACK RETARDANT TREATED STRIP SET FLUSH PLYWOOD NAILER WITH LUAUN. TRANSITION @ CARPET/NODE) FLOOR - - / 1)1 I >1 A CONTINUOUS FIRE RETARDANT TREATED PLYWOOD NAILER EFC-103 OVER F.R.T. PLYWOOD NAILER 7 - ■IF■P:, i I ■IdIMIr ..■,...■/ ra■ mr. imr.s-4■Imi■IF ■r 4.■•.,,:.4■P-A■rAmemir m....■.,.■ar .„, II II■ .■ AM. AM AM. .m. ..1.1ffitillMr.dr AM. N. 1/4" LUAUN UNDERLAYMENT I-IELD BACK 1/4" FROM WOOD FLOOR' NG. A CONTINUOUS 154* FELT PAPER BARRIER UNDER WOOD FLOOR OVER PLYWOOD NAILER ■ —1 \ F lO PF ■110 1 j10 11r ■OP r ■IIP IF .■11ffga r ld .42 A.2.7a CONCRETE FLOOR 51-A5 SCALE: 3" . 1 0 A 2.7a SEE FLOOR PLAN VARIES SCALE: 3" = 1 - 0 CONCRETE FLOOR SL-AB TRANSITION @ 1A100D/lAIOOD FLOOR 5/8" NONCOMBUSTIBLE PLYWOOD, RAMP UP TO A400D PLATFORM I • —I •S7— • Z — I \ \ p A CONTINUOUS PLYWOOD NAILER 5/8" NONCOMBUSTIBLE PLYWOOD PLATFORM OVER SLEEPERS BY G.C. SECTION THIRU RAMP MC-Ica OVER PLYWOOD NAILER En-la] Wstfieff Working Drawing Review A Approved Approved as Noted 1:1 Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- to kept on the job site at a 1 12/28/07 Si ned Date RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER NOTE: DETAILS NOTES AND/OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY 14AVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 0 N 0 t- o 7 ! G7�JJs7 /If/Y/.G_Y��f/U.4!//J?1i7 {Hl PLAN SECTION AT DOUBLE BRICK COLUMN SCALE: 1 1/2" SC ALE: I 1/2" = 1 - 0 " 5 /8" TYPE 'X' DRYWALL DOUBLE ERICK COLUMN ELEVATION II' -0" A.F.F. PREFAB. BEAM ASSEMBLY BY MILLWORK SUPPLIER WITH 3/8" DRYWALL CLADDING BY G.G. [P-4a3 10'_0" A.F.F. RICK CBR - 1a] BRICK SOLDIER COURSE TOP TRIM CBR -Ia] NOTE: LAY ERICK OUT FROM TOP - CUT BRICKS AT BOTTOM OF COLUMN FINISHED FLOOR LINE RE -SAWN PREFAB. 6" X 8" WOOF SOX SEAMS CP -3a] SUSPENDED CEILING SYSTEM • NON -COM NAILER PREFAB. CEILING BEAM ASSEMBLY (TYP.) SUSPENDED CEILING METAL NAILER SYSTEM WOOD TRIM CWD -1a] EP-3a] (-rip) METAL NAILER PREFAB CEILING BEAM ASSEMBLY PREFAB BOX EAM/k SUSPENDED CEILING SYSTEM 1!1!1!1!1!1 !1►liw 1\lll�lllir 1 ■111 ■111 ■111\ 1 PREFAB CEILING BEAM ASSEMBLY — RE -SAWN WOOD PLANKS. CWD -6a] EP-3a] (TYP. ACROSS CEILING SECTION - SEE PLAN) OOD CEILING CEILING TRIM SCALE: 3" =I' - 0" SALES AREA WALL TRIM BASE TRIM ADJACENT WALL CONSTRUCTION (TYP.) 3 %" DRYWALL EP-4a] (TYP) PREFAB. WALL PANEL SCALE: 3 " I I - 0 " LINE OF FINISHED CEILING WOOD TRIM CWD -1a3 CP -3a] (T') WOOD TRIM CWD -1a] CP -140 (TYP) PREFAB. WALL PANEL CWD -2a3 CP -Ia] (TYP) CB -1a] CP -Ia] (TYP) SUSPENDED CEILING SYSTEM �a�ata�a�a�arat ime a�agi lT�awst.c ��_I 111\1111111- 1111 1 41 11 VARIES PREFAB WOOD PLANKS CWD -6a3 CP -3a] TYP. ACROSS DECORATIVE WOOD CEILING SECTION (SEE CEILING PLAN) PREFAB WOOD BOX BEAM ASSEMBLY DETAIL SUSPENDED CEILING SYSTEM WOOD TRIM CWD -1 CP -30] (TYP.) SCALE: 3" = I' - 0" FITTIN ROOM CEILING TRIM ASSEMBLY Si fled Date NON COM- NAILER (TYP) PREFAB. WOOD BOX BEAMSCP -3a] (TYP) RECEIVED CITY OF TUKWILA FEB 0 4 2008 litstfiekt PERMIT CE Working Drawing Review CENTER Approved Approved as Noted p Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- • to r be kept on the NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 0 0 0 cNt C4 T CUSTOM HANG BAR FURN. BY TENANT INST. BY G.G. LEVER LOCKSET SCALE : 3 /4" 1 DRYWALL CP -4a1 MD-10a] [P-Ia] (TYP) BLOCKING AS REQUIRED WITHIN PANEL INDIVIDUAL COAT HOOK BOARD, FURN BY TENANT, INST BY G.C. (TYP.) POUF FURN. BY TENANT, PLACED BY G.G. (TYP. OF 2) DRYWALL EP-403 FITTI SCALE : 3/4 I' -O VERTICALLY MOUNTED T8 FLUORESCENT FIXTURE WITH DECORATIVE LENS FURN. BY TENANT, INST. BY G.C. (TYP) WOOD FRAME MIRROR CP -1a] MOUNTED WITH METAL ANGLE CLIPS, TYP. PROVIDE BLOCKING WITHIN PANEL - SEE DET. S /A.2.ga WOOD FRAME MIRROR CP -Ia], MOUNTED TO PANEL TYP. PROVIDE BLOCKING WITHIN PANEL - SEE DET. S/A.2.qa NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM $ WALL PRIOR TO PAINTING. INDIVIDUAL COAT HOOK, FURN BY TENANT, INST BY G.C. (TYP. OF 8) NOTE: IF ALLOWED BY LOCAL CODES NONCOMBUSTIBLE WOOD CAN BE SUBSTITUTED FOR NAILERS $ BLOCKING WOOD FRAME MIRROR END-103 (P-Ia], MOUNTED WITH METAL ANGLE CLIPS, TYP. PROVIDE BLOCKING WITHIN PANEL PRE - INSTALL CONDUIT IN WALL PANEL ASSEMBLY AS REQ' D. OR LIGHT FIXTURE WIRING - OORD. WITH E.C. (TYP. AT THREE WAY MIRROR LOCATIONS) VERTICALLY MOUNTED T8 FLUORESCENT FIXTURE WITH DECORATIVE LENS WOOD FRAME MIRROR END-103 EP-101, MOUNTED TO PANEL TYP. PROVIDE BLOCKING WITHIN PANEL �� SHARED PANEL BETWEEN ROOMS FITTING ROOM POUF SHOWN DASHED FURN. BY TENANT, PLACED BY G.C. (TYP. OF 2) Westfie[c[ RECEIVED CITY OF TUKWILA FEB a 4 ?.fc8 PERMIT CENTER Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir . to be kept on the job site at a I 1'2/28/07 Si•ned Date NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO 11415 PROJECT. FINISHED FACE OF GYP. BD. WALL INDIVIDUAL COAT HOOK, FURN BY TENANT, INST BY G.C. (TYP. OF 6) WRAP FABRIC UP INSIDE BEFORE INSTALLING PLYWOOD SOTTO FULL REMOVABLE PLYWOOD BOTTOM NOT TO SCALE - iii::: a� _��I.._:��_:::����►�i.._:�� - -= 6 i SECTION 30 X 48 CLEAR FLOOR AREA N.C. FITTING ROOM PLAN BRUSHED COLD ROLLED STEEL WALL BRACKET PADDED FABRIC SIDE ELEVATION BRACKET DETAIL R00" "POU " EA _S WOOD FRAME CND -Ia] CP -1a] MIRROR, MOUNTED WITH METAL ANGLE CLIPS, TYP. PROVIDE BLOCKING WITHIN PANEL WOOD FRAME CWD -Ia] CP -1a] MIRROR, MOUNTED TO PANEL TYP. PROVIDE BLOCKING WITHIN PANEL A_______ ATTACHED FABRIC CUSHION, NO BUTTON WELTING FOOT - HICKORY WOOD MED. STAIN, TAPER 2 SIDES 24 X 48 PREFAB. POUF FURN. BY TENANT, INST. BY G.C. (TYP) R A.2.qb DRYWALL CP -4a] SCALE 3/4" m 1 1 - CWD -IOa] CP -la] (TYP) H.C. FITTING ROOM DETAIL DRYWALL [P -40] N.C. FITTING ROOM DETAIL WOOD FRAME CP -1•] MIRROR bOUNTED WITH METAL ANGLE CLIPS, TYP. PROVIDE BLOCKING WITHIN PANEL - SEE DET. S /A.2 -qa WOOD FRAME CP -Ia] MIRROR, MOUNTED TO PANEL TYP. PROVIDE BLOCKING WITHIN PANEL - SEE DET. S /A.2.ga BLOCKING AS REQUIRED WITHIN PANEL INDIVIDUAL COAT HOOK HOARD, FURN BY TENANT, INST BY G.C. (TYP.) WALLCOVERING NOTE: WALLPAPER FURN. BY TENANT, INST. EY G.C. OVER NON - ROUTED MDF PANEL- - PATTERN T.B.D. - TYP. OF WALLS ADJACENT TO 3 -WAY MIRROR NOTE: PAINTING CONTRACTOR SHALL CAULK AILL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM $ WALL PRIOR TO PAINTING. DRYWALL EP DRYWALL [P -4a] SCALE : 3/4 1 -0" A.2I.9a NOTE: IF ALLOWED BY LOCAL CODES NONCOMSUSTISLE WOOD CAN SE SUBSTITUTED FOR NAILERS $ BLOCKING DRYWALL [P -40] H.C. FITTING ROOM DETAIL I I1 H II CWD -10a ] CP -Ia] (TYP N.C. FITTING ROOM DETAIL BRUSHED COLD ROLLED STEEL WALL BRACKET SEE DETAILS THIS SHEET LEVER LOCKSET lVestIle[d Working Drawing Review q Approve d Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir• . to be kept on the j ob sCe at a I /28/07 r Si.ned Date DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE SEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. A.2.9b 8' -O" A.F.F. A A.2.9b WOOD POST CWD -1a3 CP -103 HEADER ABV. SHOW DASHED HEAD DETAIL HEADER ABV. SHOW DASHED WOOD TRIM CWD -1a] EP-1a3 (m') WOOD HEADER CND -la] EP-Ia] (TYP) SCALE: 3 WOOD POST BEYOND DOOR JAMB 8 A.2.9b WOOD POST CWD -1a] EP-Ial WOOD TRIM CWD -1a] EP-Ia] (P) EAD TRIM DETAIL WALL SCALE: 3" s 1 - 0 11 WOOD FRAME PANEL DOOR JAMB CWD -1a3 EP-la HEADER ASV. SHOWN DASHED 5/8" DRYWALL EP-4.1a3 WOOD HEADER TRIM CWD -103 trwq- (TYP) (TYP) WOOD FRAME PANEL ASSEMBLY (TYP.) WOOD POST 4 TRIM BEYOND SCALE: 311a11 -0" SCALE: 3 G A.2.9b DOOR JAMB N.C. OO JAMB HEAD TRIM DETAIL SCALE: 3 a 1` - 0" WOOD TRIM CWD -la] CF'-1a] (TYP) CHAMFER (TYP.) WOOD POST CWD -Ia] CP -Ia] WOOD TRIM CWD -1a] EP-1a) (TYP) =lam y MDF BEAD BOARD CWD -10a1 EP-la] (TYP BOTH SIDES) HEADER ABV. SHOWN DASHED WOOD FRAME PANEL ASSEMBLY (TYP.) WOOD TRIM CWD -1a] CP -1a] (TYP) WOOD POST TRIM BEYOND WOOD FRAME PANEL ASSEMBLY (TYP.) DOOR JAMB CWD -1a] EP-la HEADER ASV. SHOWN DASHED HEADER ABV. SHOWN DASHED D A.2.9b SCALE: 3" 1 1 - 0 " SCALE: 3 II - 0" Q A.2.9b SCALE: 3" = 1' - 0" WOOD BASE TRIM CWD -la] EP-la] (TYP) WOOD POST TRIM BEYOND i fFINISHED FLOOR BASE ?RIM DETAIL JOINING POST DETAIL �i Il lr'fi`~ H.C. DOOR JAMS WOOD TRIM CWD -1a3 CP -Ia] (TYP) E A.2.9b WOOD TRIM CWD -1a] CP -10] (TYP) Y MDF BEAD BOARD END-1003 EP-Ia] (TYP. BOTH SIDES) CHAMFER (TYP_) WOOD POST CND -1a1 EP-1a3 BASE TRIM DETAIL @ WALL SCALE: 3" I' - 0" WOOD FRAME PANEL ASSEMBLY (TYP.) HEADER ABV. SHOWN DASHED WOOD TRIM CWD -103 CP -10] (') R A.2.9b SCALE: 3" WOOD POST r TRIM BEYOND 5/8" DRYWALL CP -4a3 B -la] CP -101 (TT.) B -2a] CP -1a3 (TYP.) INISHED FLOOR THREE WAY MIRROR DETAIL WOOD POST CWD -Ia] CP -1a3 CHAMFER (TYP.) n POST AT WALL DETAIL NON -COM WOOD BLOCKING WITHIN PANEL PRE- INSTALL CONDUIT IN WALL PANEL ASSEMBLY AS REQ'D. FOR LIGHT FIXTURE WIRING - COORD. WITH E.C. (TYP. AT THREE WAY MIRROR LOCATIONS) WOOD FRAME MIRROR (TYP. OF 3 PER FITTING ROOM) MOUNTED TO PANEL. FURN. BY TENANT, INSTALLED BY G.C. RECEIVED CITY OF TUKWILA FEB 0 4 2003 PERMIT CENTER Wsffieff Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all govemment regulations. One (1) copy of this landlord stamped set of drawings Is requir - . tope kept on an the site at a 1 1,2/28/07 Si•ned Date NOTE: PAINTING CONTRACTOR SI -IALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM * WALL PRIOR TO PAINTING. NOTE: IF ALLOWED BY LOCAL CODES NONCOMBUSTIBLE WOOD CAN BE SUBSTITUTED FOR NAILERS 4 BLOCKING NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY WAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. AUTO FLUSH 130LT TOP ONLY tI PREFAB. CUSTOM DOOR PUSH/PULLS FURN. BY TENANT INST. BY G.G. BEYOND (TYP OF 3) BP61PABCHO STOCKROOM - LOS URE MOUNT ON SALES SIDE SING PARALLEL ARM CUNT $ SEX BOLTS FURN. Y TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE PRE - INSTALLED KICK PLATE DOOR ( 'AERIE' ENTRY - EXTERIOR) 3 ' - (CLEAR) (HOLD) 0 v 1% NOTE: DUST PROOF STRIKE #570 -26D TO BE INSTALLED IN ENTRY FLOOR (TYP OF 2) DOOR ( 'AERIE' ENTRY .INTERIOR) SCALE: 1/2" = 1' - 011 DOOR THUMB TURN (STOCKROOM DOOR - PUBLIC SIDE) DOOR ELEVATIONS PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. # INST. BY G.G. PRESTAINED FULL LITE WOOD (PRE- MACHINED) DOOR 4 1/2" X 4 1/2" -26D NRP 88 PRESTAINED FULL LITE WOOD (PRE -MACI- LINED) DOOR 1279 HINGE (TYP. OF 3) PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. * INST. BY G.C. , CUSTOM DOOR PUSH /PULLS 22 FURN. BY TENANT INST. BY G.C. SURFACE BOLT #3538 -26D NOTE: *4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (FREHUNG) [P-1a3 "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.G. SEE SHEET 'A.2.12' FOR MORE DETAIL FINISH FLOOR LINE WOOD DOOR CASING CWD -Ia] CP -Ia] #5965 -26D 2 3/4" PASSAGE PUSH /PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S441A1 " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. STANDARD SATIN ALUMINUM HINGE (TYP. OF 2) 4BP6IPA5CHO STOCKROOM CLOSURE - (MOUNT ON INTERIOR OF DOOR USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) #TY37B4841N -26D DOOR VIEWER #155 DKB PERIMETER SEAL (2) 84 #(1)42' GENERAL NOTE: DOOR, FRAME AND HARDWARE FURN. BY TENANT, INST. BY G.G. S- LABEL SMOKE SEAL (MN. 20 MINUTE SMOKE RATING) -PEMK S44W " SILLICONSEAL' NOTE: #4041 -26 WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. t (TOILET ROOM DOOR- STOCK SIDE) 0 DOOR 3' -0" 31 0 11 EXIT FINISH #q8V DKB 42" FLOOR DOOR SWEEP LINE DOOR 3' -0' L _ -- DOOR (SERVICE DOOR - INTERIOR VIEW) NOTE: #4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. r � 4a (SERVICE DOOR - EXTERIOR VIEW) 0 NOTE: EXIT DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT. Q- 4 1/2" X 4 1/2" NRP PRIMECOAT HINGES (TYP. OF 3) 3/4 "x3 1/2" WOOD DOOR CASING [WD -1] CP -2] (TYP.) G.G. TO FURN. $ INSTALL H .C. $ M/F SIGNS W ITH CONTRASTING COLORS IN 8 " M ACCORDANCE WITH THE ADA H.C. SIGN IS TO BE BLUE ON WHITE #SPI76BSN -26 D PRIVACY 2 3/4 SET (G.C. MUST INSTALL W/ 2 3/3" BACKSET USING #V21g00 722 -26D LATCH) HOLLOW CORE WOOD (PREHUNG $ PREMACHINED) DOOR EP -2] UNDERCUT DOOR 1 1/2" FINISH FLOOR LINE EXIT SIGN FURN. BY TENANT INSTALLED BY G.C. HOLLOW METAL JAMB (PAINT TO MATCH MALL STANDARD) +FOLLOW METAL, 90 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) #P531 DOOR PULL *AL700 PANIC ALARM BAR S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S44W "SILLICONSEAL" NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED HOLLOW METAL, 410 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) G.C. SHALL FURN 4 INST. SIGN OR STENCIL "AERIE SPACE NO. LANDLORD REQUIREMENTS. #DJPDF -161PC HOLE FILLER #DJEF -161PC EDGE FILLER (NOT SHOWN) #DJFA.1,12060PC FRAME FILLER (NOT SHOWN) �-- PUSHBUTTON -FURN. BY TENANT INSTALLED BY E.C. NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED CUSTOM HANG BAR FURN. BY TENANT INST. BY G.C. #SP1I5BSN -26D PRIVACY 2 3/4" LEVER LOCKSET NOTE: 1#4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL _ ADJACENT TO HINGES. DOOR BOLT To fn I co FINISH FLOOR L NE #BP6IPABCHO STOCKROOM - CLOSURE (MOUNT ON SALES SIDE USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE BEYOND (TYP OF 3) PRE- INSTALLED KICK PLATE 3/4 "x3 1/2" WOOD DOOR TRIM [WO -1a] [P -Ia] (TYP) o DOOR DOOR OPEN 3' DOOR (VESTIBULE OPENING) (INTERIOR FITTING ROOM DOOR VIEW) (COMPUTER ROOM DOOR - PUBLIC SIDE) FINISH FLOOR LINE NOTE: SEE DOOR JAMB DETAILS ON SHEET 'A.2_ga' FOR VARIOUS CONDITIONS - COORD. W/ FLOOR PLAN. WOOD POST CP -103 WOOD (PREHUNG 4 PREMACHINED) DOOR [P-1a3 3 1/2" X 3 1/2" -26D IT STANDARD HINGE (MIDDLE DOOR ONLY) m 3 1/2" X 3 1/2" -26D SPRING HINGES #RC1252 (TYP OF 2) (TOP AND BOTTOM ONLY) NOTE: 1:40q -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (PREHUNG) [P -Ia] "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.C. SEE SHEET 'A.2.12' FOR MORE DETAIL WOOD DOOR CASING [ND -103 [P-1a3 #54165 -26D 2 3/4" PASSAGE PUSH/PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 944W " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. FINISH FLOOR LINE NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALP1- IABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 9441 " SILLICONSEAL" A.2.10 METAL DOOR KICK PLATE W/ EXPOSED BLACK OXIDE FASTENERS CM -1a] E DOOR STOP CWD -111] CP -la] B III A.2.10 I- IOLLOW METAL 16 GA. KD JAMB [P -Ia] STOCKROOM DOOR METAL STUD NAILER FURN. BY TENANT, INST. BY G.G. STANDARD DOOR JAMB CP -1a] DOOR STOP [P -la] TOILET ROOM DOOR 3/4 "x3 1/2" WOOD TRIM [ND -103 CP -1a3 (TYP. BOTH SIDES) FITTING ROOM DOOR METAL STUD NAILER - INST. FURN. BY BY G.C. TENANT, DOOR 00 DOOR JAMB DETAILS SCALE: 11/2" 1) 0,5 050 SCALE: 1" = I' - 0" DOOR 11 - 0 4 VESTIBULE STOCKROOM DOOR 1x4 WOOD TRIM CWD -la] CP -lo] METAL STUD NAILER DRYWALL 3 5/8" METAL STUD FRAMING 3/4 "x3 1/2" WOOD CASING [P -Ia] (TYP.) FITTING ROOM 1 11 4 [WD -2a] [P-1a3 3 5/8" METAL STUD FRAMING VESTIBULE MOUNTING HARDWARE FURN. BY TENANT, INST. BY G.C. 5/8" DRYWALL CP -2a] 5/8" DRYWALL PRIME ONLY REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 1 ?.006 City 0fTuI Ia BUILDING DIVISION DRYWALL CP -2a] Wst/leId Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual Field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir• . to be kept on the job site at a I l2$la7 Si•ned Date DOOR PLATE DETAILS RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER tO 0 0 0 01 MIN ii I YALE D E , F f hNlht �O tj f l A b - ....._______ si 191 j_OF HINGE r N‘ .::„t::::.. i , t AUTO FLUSH 130LT TOP ONLY tI PREFAB. CUSTOM DOOR PUSH/PULLS FURN. BY TENANT INST. BY G.G. BEYOND (TYP OF 3) BP61PABCHO STOCKROOM - LOS URE MOUNT ON SALES SIDE SING PARALLEL ARM CUNT $ SEX BOLTS FURN. Y TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE PRE - INSTALLED KICK PLATE DOOR ( 'AERIE' ENTRY - EXTERIOR) 3 ' - (CLEAR) (HOLD) 0 v 1% NOTE: DUST PROOF STRIKE #570 -26D TO BE INSTALLED IN ENTRY FLOOR (TYP OF 2) DOOR ( 'AERIE' ENTRY .INTERIOR) SCALE: 1/2" = 1' - 011 DOOR THUMB TURN (STOCKROOM DOOR - PUBLIC SIDE) DOOR ELEVATIONS PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. # INST. BY G.G. PRESTAINED FULL LITE WOOD (PRE- MACHINED) DOOR 4 1/2" X 4 1/2" -26D NRP 88 PRESTAINED FULL LITE WOOD (PRE -MACI- LINED) DOOR 1279 HINGE (TYP. OF 3) PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. * INST. BY G.C. , CUSTOM DOOR PUSH /PULLS 22 FURN. BY TENANT INST. BY G.C. SURFACE BOLT #3538 -26D NOTE: *4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (FREHUNG) [P-1a3 "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.G. SEE SHEET 'A.2.12' FOR MORE DETAIL FINISH FLOOR LINE WOOD DOOR CASING CWD -Ia] CP -Ia] #5965 -26D 2 3/4" PASSAGE PUSH /PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S441A1 " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. STANDARD SATIN ALUMINUM HINGE (TYP. OF 2) 4BP6IPA5CHO STOCKROOM CLOSURE - (MOUNT ON INTERIOR OF DOOR USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) #TY37B4841N -26D DOOR VIEWER #155 DKB PERIMETER SEAL (2) 84 #(1)42' GENERAL NOTE: DOOR, FRAME AND HARDWARE FURN. BY TENANT, INST. BY G.G. S- LABEL SMOKE SEAL (MN. 20 MINUTE SMOKE RATING) -PEMK S44W " SILLICONSEAL' NOTE: #4041 -26 WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. t (TOILET ROOM DOOR- STOCK SIDE) 0 DOOR 3' -0" 31 0 11 EXIT FINISH #q8V DKB 42" FLOOR DOOR SWEEP LINE DOOR 3' -0' L _ -- DOOR (SERVICE DOOR - INTERIOR VIEW) NOTE: #4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. r � 4a (SERVICE DOOR - EXTERIOR VIEW) 0 NOTE: EXIT DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT. Q- 4 1/2" X 4 1/2" NRP PRIMECOAT HINGES (TYP. OF 3) 3/4 "x3 1/2" WOOD DOOR CASING [WD -1] CP -2] (TYP.) G.G. TO FURN. $ INSTALL H .C. $ M/F SIGNS W ITH CONTRASTING COLORS IN 8 " M ACCORDANCE WITH THE ADA H.C. SIGN IS TO BE BLUE ON WHITE #SPI76BSN -26 D PRIVACY 2 3/4 SET (G.C. MUST INSTALL W/ 2 3/3" BACKSET USING #V21g00 722 -26D LATCH) HOLLOW CORE WOOD (PREHUNG $ PREMACHINED) DOOR EP -2] UNDERCUT DOOR 1 1/2" FINISH FLOOR LINE EXIT SIGN FURN. BY TENANT INSTALLED BY G.C. HOLLOW METAL JAMB (PAINT TO MATCH MALL STANDARD) +FOLLOW METAL, 90 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) #P531 DOOR PULL *AL700 PANIC ALARM BAR S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S44W "SILLICONSEAL" NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED HOLLOW METAL, 410 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) G.C. SHALL FURN 4 INST. SIGN OR STENCIL "AERIE SPACE NO. LANDLORD REQUIREMENTS. #DJPDF -161PC HOLE FILLER #DJEF -161PC EDGE FILLER (NOT SHOWN) #DJFA.1,12060PC FRAME FILLER (NOT SHOWN) �-- PUSHBUTTON -FURN. BY TENANT INSTALLED BY E.C. NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED CUSTOM HANG BAR FURN. BY TENANT INST. BY G.C. #SP1I5BSN -26D PRIVACY 2 3/4" LEVER LOCKSET NOTE: 1#4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL _ ADJACENT TO HINGES. DOOR BOLT To fn I co FINISH FLOOR L NE #BP6IPABCHO STOCKROOM - CLOSURE (MOUNT ON SALES SIDE USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE BEYOND (TYP OF 3) PRE- INSTALLED KICK PLATE 3/4 "x3 1/2" WOOD DOOR TRIM [WO -1a] [P -Ia] (TYP) o DOOR DOOR OPEN 3' DOOR (VESTIBULE OPENING) (INTERIOR FITTING ROOM DOOR VIEW) (COMPUTER ROOM DOOR - PUBLIC SIDE) FINISH FLOOR LINE NOTE: SEE DOOR JAMB DETAILS ON SHEET 'A.2_ga' FOR VARIOUS CONDITIONS - COORD. W/ FLOOR PLAN. WOOD POST CP -103 WOOD (PREHUNG 4 PREMACHINED) DOOR [P-1a3 3 1/2" X 3 1/2" -26D IT STANDARD HINGE (MIDDLE DOOR ONLY) m 3 1/2" X 3 1/2" -26D SPRING HINGES #RC1252 (TYP OF 2) (TOP AND BOTTOM ONLY) NOTE: 1:40q -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (PREHUNG) [P -Ia] "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.C. SEE SHEET 'A.2.12' FOR MORE DETAIL WOOD DOOR CASING [ND -103 [P-1a3 #54165 -26D 2 3/4" PASSAGE PUSH/PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 944W " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. FINISH FLOOR LINE NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALP1- IABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 9441 " SILLICONSEAL" A.2.10 METAL DOOR KICK PLATE W/ EXPOSED BLACK OXIDE FASTENERS CM -1a] E DOOR STOP CWD -111] CP -la] B III A.2.10 I- IOLLOW METAL 16 GA. KD JAMB [P -Ia] STOCKROOM DOOR METAL STUD NAILER FURN. BY TENANT, INST. BY G.G. STANDARD DOOR JAMB CP -1a] DOOR STOP [P -la] TOILET ROOM DOOR 3/4 "x3 1/2" WOOD TRIM [ND -103 CP -1a3 (TYP. BOTH SIDES) FITTING ROOM DOOR METAL STUD NAILER - INST. FURN. BY BY G.C. TENANT, DOOR 00 DOOR JAMB DETAILS SCALE: 11/2" 1) 0,5 050 SCALE: 1" = I' - 0" DOOR 11 - 0 4 VESTIBULE STOCKROOM DOOR 1x4 WOOD TRIM CWD -la] CP -lo] METAL STUD NAILER DRYWALL 3 5/8" METAL STUD FRAMING 3/4 "x3 1/2" WOOD CASING [P -Ia] (TYP.) FITTING ROOM 1 11 4 [WD -2a] [P-1a3 3 5/8" METAL STUD FRAMING VESTIBULE MOUNTING HARDWARE FURN. BY TENANT, INST. BY G.C. 5/8" DRYWALL CP -2a] 5/8" DRYWALL PRIME ONLY REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 1 ?.006 City 0fTuI Ia BUILDING DIVISION DRYWALL CP -2a] Wst/leId Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual Field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir• . to be kept on the job site at a I l2$la7 Si•ned Date DOOR PLATE DETAILS RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER tO 0 0 0 01 MIN ii I � , =MI t t f l A ... - ....._______ si 191 .::„t::::.. lc AUTO FLUSH 130LT TOP ONLY tI PREFAB. CUSTOM DOOR PUSH/PULLS FURN. BY TENANT INST. BY G.G. BEYOND (TYP OF 3) BP61PABCHO STOCKROOM - LOS URE MOUNT ON SALES SIDE SING PARALLEL ARM CUNT $ SEX BOLTS FURN. Y TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE PRE - INSTALLED KICK PLATE DOOR ( 'AERIE' ENTRY - EXTERIOR) 3 ' - (CLEAR) (HOLD) 0 v 1% NOTE: DUST PROOF STRIKE #570 -26D TO BE INSTALLED IN ENTRY FLOOR (TYP OF 2) DOOR ( 'AERIE' ENTRY .INTERIOR) SCALE: 1/2" = 1' - 011 DOOR THUMB TURN (STOCKROOM DOOR - PUBLIC SIDE) DOOR ELEVATIONS PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. # INST. BY G.G. PRESTAINED FULL LITE WOOD (PRE- MACHINED) DOOR 4 1/2" X 4 1/2" -26D NRP 88 PRESTAINED FULL LITE WOOD (PRE -MACI- LINED) DOOR 1279 HINGE (TYP. OF 3) PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. * INST. BY G.C. , CUSTOM DOOR PUSH /PULLS 22 FURN. BY TENANT INST. BY G.C. SURFACE BOLT #3538 -26D NOTE: *4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (FREHUNG) [P-1a3 "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.G. SEE SHEET 'A.2.12' FOR MORE DETAIL FINISH FLOOR LINE WOOD DOOR CASING CWD -Ia] CP -Ia] #5965 -26D 2 3/4" PASSAGE PUSH /PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S441A1 " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. STANDARD SATIN ALUMINUM HINGE (TYP. OF 2) 4BP6IPA5CHO STOCKROOM CLOSURE - (MOUNT ON INTERIOR OF DOOR USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) #TY37B4841N -26D DOOR VIEWER #155 DKB PERIMETER SEAL (2) 84 #(1)42' GENERAL NOTE: DOOR, FRAME AND HARDWARE FURN. BY TENANT, INST. BY G.G. S- LABEL SMOKE SEAL (MN. 20 MINUTE SMOKE RATING) -PEMK S44W " SILLICONSEAL' NOTE: #4041 -26 WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. t (TOILET ROOM DOOR- STOCK SIDE) 0 DOOR 3' -0" 31 0 11 EXIT FINISH #q8V DKB 42" FLOOR DOOR SWEEP LINE DOOR 3' -0' L _ -- DOOR (SERVICE DOOR - INTERIOR VIEW) NOTE: #4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. r � 4a (SERVICE DOOR - EXTERIOR VIEW) 0 NOTE: EXIT DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT. Q- 4 1/2" X 4 1/2" NRP PRIMECOAT HINGES (TYP. OF 3) 3/4 "x3 1/2" WOOD DOOR CASING [WD -1] CP -2] (TYP.) G.G. TO FURN. $ INSTALL H .C. $ M/F SIGNS W ITH CONTRASTING COLORS IN 8 " M ACCORDANCE WITH THE ADA H.C. SIGN IS TO BE BLUE ON WHITE #SPI76BSN -26 D PRIVACY 2 3/4 SET (G.C. MUST INSTALL W/ 2 3/3" BACKSET USING #V21g00 722 -26D LATCH) HOLLOW CORE WOOD (PREHUNG $ PREMACHINED) DOOR EP -2] UNDERCUT DOOR 1 1/2" FINISH FLOOR LINE EXIT SIGN FURN. BY TENANT INSTALLED BY G.C. HOLLOW METAL JAMB (PAINT TO MATCH MALL STANDARD) +FOLLOW METAL, 90 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) #P531 DOOR PULL *AL700 PANIC ALARM BAR S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S44W "SILLICONSEAL" NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED HOLLOW METAL, 410 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) G.C. SHALL FURN 4 INST. SIGN OR STENCIL "AERIE SPACE NO. LANDLORD REQUIREMENTS. #DJPDF -161PC HOLE FILLER #DJEF -161PC EDGE FILLER (NOT SHOWN) #DJFA.1,12060PC FRAME FILLER (NOT SHOWN) �-- PUSHBUTTON -FURN. BY TENANT INSTALLED BY E.C. NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED CUSTOM HANG BAR FURN. BY TENANT INST. BY G.C. #SP1I5BSN -26D PRIVACY 2 3/4" LEVER LOCKSET NOTE: 1#4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL _ ADJACENT TO HINGES. DOOR BOLT To fn I co FINISH FLOOR L NE #BP6IPABCHO STOCKROOM - CLOSURE (MOUNT ON SALES SIDE USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE BEYOND (TYP OF 3) PRE- INSTALLED KICK PLATE 3/4 "x3 1/2" WOOD DOOR TRIM [WO -1a] [P -Ia] (TYP) o DOOR DOOR OPEN 3' DOOR (VESTIBULE OPENING) (INTERIOR FITTING ROOM DOOR VIEW) (COMPUTER ROOM DOOR - PUBLIC SIDE) FINISH FLOOR LINE NOTE: SEE DOOR JAMB DETAILS ON SHEET 'A.2_ga' FOR VARIOUS CONDITIONS - COORD. W/ FLOOR PLAN. WOOD POST CP -103 WOOD (PREHUNG 4 PREMACHINED) DOOR [P-1a3 3 1/2" X 3 1/2" -26D IT STANDARD HINGE (MIDDLE DOOR ONLY) m 3 1/2" X 3 1/2" -26D SPRING HINGES #RC1252 (TYP OF 2) (TOP AND BOTTOM ONLY) NOTE: 1:40q -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (PREHUNG) [P -Ia] "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.C. SEE SHEET 'A.2.12' FOR MORE DETAIL WOOD DOOR CASING [ND -103 [P-1a3 #54165 -26D 2 3/4" PASSAGE PUSH/PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 944W " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. FINISH FLOOR LINE NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALP1- IABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 9441 " SILLICONSEAL" A.2.10 METAL DOOR KICK PLATE W/ EXPOSED BLACK OXIDE FASTENERS CM -1a] E DOOR STOP CWD -111] CP -la] B III A.2.10 I- IOLLOW METAL 16 GA. KD JAMB [P -Ia] STOCKROOM DOOR METAL STUD NAILER FURN. BY TENANT, INST. BY G.G. STANDARD DOOR JAMB CP -1a] DOOR STOP [P -la] TOILET ROOM DOOR 3/4 "x3 1/2" WOOD TRIM [ND -103 CP -1a3 (TYP. BOTH SIDES) FITTING ROOM DOOR METAL STUD NAILER - INST. FURN. BY BY G.C. TENANT, DOOR 00 DOOR JAMB DETAILS SCALE: 11/2" 1) 0,5 050 SCALE: 1" = I' - 0" DOOR 11 - 0 4 VESTIBULE STOCKROOM DOOR 1x4 WOOD TRIM CWD -la] CP -lo] METAL STUD NAILER DRYWALL 3 5/8" METAL STUD FRAMING 3/4 "x3 1/2" WOOD CASING [P -Ia] (TYP.) FITTING ROOM 1 11 4 [WD -2a] [P-1a3 3 5/8" METAL STUD FRAMING VESTIBULE MOUNTING HARDWARE FURN. BY TENANT, INST. BY G.C. 5/8" DRYWALL CP -2a] 5/8" DRYWALL PRIME ONLY REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 1 ?.006 City 0fTuI Ia BUILDING DIVISION DRYWALL CP -2a] Wst/leId Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual Field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir• . to be kept on the job site at a I l2$la7 Si•ned Date DOOR PLATE DETAILS RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER tO 0 0 0 01 MIN ii I I 1 J 1 , AUTO FLUSH 130LT TOP ONLY tI PREFAB. CUSTOM DOOR PUSH/PULLS FURN. BY TENANT INST. BY G.G. BEYOND (TYP OF 3) BP61PABCHO STOCKROOM - LOS URE MOUNT ON SALES SIDE SING PARALLEL ARM CUNT $ SEX BOLTS FURN. Y TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE PRE - INSTALLED KICK PLATE DOOR ( 'AERIE' ENTRY - EXTERIOR) 3 ' - (CLEAR) (HOLD) 0 v 1% NOTE: DUST PROOF STRIKE #570 -26D TO BE INSTALLED IN ENTRY FLOOR (TYP OF 2) DOOR ( 'AERIE' ENTRY .INTERIOR) SCALE: 1/2" = 1' - 011 DOOR THUMB TURN (STOCKROOM DOOR - PUBLIC SIDE) DOOR ELEVATIONS PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. # INST. BY G.G. PRESTAINED FULL LITE WOOD (PRE- MACHINED) DOOR 4 1/2" X 4 1/2" -26D NRP 88 PRESTAINED FULL LITE WOOD (PRE -MACI- LINED) DOOR 1279 HINGE (TYP. OF 3) PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. * INST. BY G.C. , CUSTOM DOOR PUSH /PULLS 22 FURN. BY TENANT INST. BY G.C. SURFACE BOLT #3538 -26D NOTE: *4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (FREHUNG) [P-1a3 "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.G. SEE SHEET 'A.2.12' FOR MORE DETAIL FINISH FLOOR LINE WOOD DOOR CASING CWD -Ia] CP -Ia] #5965 -26D 2 3/4" PASSAGE PUSH /PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S441A1 " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. STANDARD SATIN ALUMINUM HINGE (TYP. OF 2) 4BP6IPA5CHO STOCKROOM CLOSURE - (MOUNT ON INTERIOR OF DOOR USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) #TY37B4841N -26D DOOR VIEWER #155 DKB PERIMETER SEAL (2) 84 #(1)42' GENERAL NOTE: DOOR, FRAME AND HARDWARE FURN. BY TENANT, INST. BY G.G. S- LABEL SMOKE SEAL (MN. 20 MINUTE SMOKE RATING) -PEMK S44W " SILLICONSEAL' NOTE: #4041 -26 WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. t (TOILET ROOM DOOR- STOCK SIDE) 0 DOOR 3' -0" 31 0 11 EXIT FINISH #q8V DKB 42" FLOOR DOOR SWEEP LINE DOOR 3' -0' L _ -- DOOR (SERVICE DOOR - INTERIOR VIEW) NOTE: #4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. r � 4a (SERVICE DOOR - EXTERIOR VIEW) 0 NOTE: EXIT DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT. Q- 4 1/2" X 4 1/2" NRP PRIMECOAT HINGES (TYP. OF 3) 3/4 "x3 1/2" WOOD DOOR CASING [WD -1] CP -2] (TYP.) G.G. TO FURN. $ INSTALL H .C. $ M/F SIGNS W ITH CONTRASTING COLORS IN 8 " M ACCORDANCE WITH THE ADA H.C. SIGN IS TO BE BLUE ON WHITE #SPI76BSN -26 D PRIVACY 2 3/4 SET (G.C. MUST INSTALL W/ 2 3/3" BACKSET USING #V21g00 722 -26D LATCH) HOLLOW CORE WOOD (PREHUNG $ PREMACHINED) DOOR EP -2] UNDERCUT DOOR 1 1/2" FINISH FLOOR LINE EXIT SIGN FURN. BY TENANT INSTALLED BY G.C. HOLLOW METAL JAMB (PAINT TO MATCH MALL STANDARD) +FOLLOW METAL, 90 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) #P531 DOOR PULL *AL700 PANIC ALARM BAR S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S44W "SILLICONSEAL" NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED HOLLOW METAL, 410 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) G.C. SHALL FURN 4 INST. SIGN OR STENCIL "AERIE SPACE NO. LANDLORD REQUIREMENTS. #DJPDF -161PC HOLE FILLER #DJEF -161PC EDGE FILLER (NOT SHOWN) #DJFA.1,12060PC FRAME FILLER (NOT SHOWN) �-- PUSHBUTTON -FURN. BY TENANT INSTALLED BY E.C. NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED CUSTOM HANG BAR FURN. BY TENANT INST. BY G.C. #SP1I5BSN -26D PRIVACY 2 3/4" LEVER LOCKSET NOTE: 1#4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL _ ADJACENT TO HINGES. DOOR BOLT To fn I co FINISH FLOOR L NE #BP6IPABCHO STOCKROOM - CLOSURE (MOUNT ON SALES SIDE USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE BEYOND (TYP OF 3) PRE- INSTALLED KICK PLATE 3/4 "x3 1/2" WOOD DOOR TRIM [WO -1a] [P -Ia] (TYP) o DOOR DOOR OPEN 3' DOOR (VESTIBULE OPENING) (INTERIOR FITTING ROOM DOOR VIEW) (COMPUTER ROOM DOOR - PUBLIC SIDE) FINISH FLOOR LINE NOTE: SEE DOOR JAMB DETAILS ON SHEET 'A.2_ga' FOR VARIOUS CONDITIONS - COORD. W/ FLOOR PLAN. WOOD POST CP -103 WOOD (PREHUNG 4 PREMACHINED) DOOR [P-1a3 3 1/2" X 3 1/2" -26D IT STANDARD HINGE (MIDDLE DOOR ONLY) m 3 1/2" X 3 1/2" -26D SPRING HINGES #RC1252 (TYP OF 2) (TOP AND BOTTOM ONLY) NOTE: 1:40q -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (PREHUNG) [P -Ia] "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.C. SEE SHEET 'A.2.12' FOR MORE DETAIL WOOD DOOR CASING [ND -103 [P-1a3 #54165 -26D 2 3/4" PASSAGE PUSH/PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 944W " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. FINISH FLOOR LINE NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALP1- IABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 9441 " SILLICONSEAL" A.2.10 METAL DOOR KICK PLATE W/ EXPOSED BLACK OXIDE FASTENERS CM -1a] E DOOR STOP CWD -111] CP -la] B III A.2.10 I- IOLLOW METAL 16 GA. KD JAMB [P -Ia] STOCKROOM DOOR METAL STUD NAILER FURN. BY TENANT, INST. BY G.G. STANDARD DOOR JAMB CP -1a] DOOR STOP [P -la] TOILET ROOM DOOR 3/4 "x3 1/2" WOOD TRIM [ND -103 CP -1a3 (TYP. BOTH SIDES) FITTING ROOM DOOR METAL STUD NAILER - INST. FURN. BY BY G.C. TENANT, DOOR 00 DOOR JAMB DETAILS SCALE: 11/2" 1) 0,5 050 SCALE: 1" = I' - 0" DOOR 11 - 0 4 VESTIBULE STOCKROOM DOOR 1x4 WOOD TRIM CWD -la] CP -lo] METAL STUD NAILER DRYWALL 3 5/8" METAL STUD FRAMING 3/4 "x3 1/2" WOOD CASING [P -Ia] (TYP.) FITTING ROOM 1 11 4 [WD -2a] [P-1a3 3 5/8" METAL STUD FRAMING VESTIBULE MOUNTING HARDWARE FURN. BY TENANT, INST. BY G.C. 5/8" DRYWALL CP -2a] 5/8" DRYWALL PRIME ONLY REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 1 ?.006 City 0fTuI Ia BUILDING DIVISION DRYWALL CP -2a] Wst/leId Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual Field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir• . to be kept on the job site at a I l2$la7 Si•ned Date DOOR PLATE DETAILS RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER tO 0 0 0 01 EQUAL EQUAL EQUAL , =MI l A - V AUTO FLUSH 130LT TOP ONLY tI PREFAB. CUSTOM DOOR PUSH/PULLS FURN. BY TENANT INST. BY G.G. BEYOND (TYP OF 3) BP61PABCHO STOCKROOM - LOS URE MOUNT ON SALES SIDE SING PARALLEL ARM CUNT $ SEX BOLTS FURN. Y TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE PRE - INSTALLED KICK PLATE DOOR ( 'AERIE' ENTRY - EXTERIOR) 3 ' - (CLEAR) (HOLD) 0 v 1% NOTE: DUST PROOF STRIKE #570 -26D TO BE INSTALLED IN ENTRY FLOOR (TYP OF 2) DOOR ( 'AERIE' ENTRY .INTERIOR) SCALE: 1/2" = 1' - 011 DOOR THUMB TURN (STOCKROOM DOOR - PUBLIC SIDE) DOOR ELEVATIONS PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. # INST. BY G.G. PRESTAINED FULL LITE WOOD (PRE- MACHINED) DOOR 4 1/2" X 4 1/2" -26D NRP 88 PRESTAINED FULL LITE WOOD (PRE -MACI- LINED) DOOR 1279 HINGE (TYP. OF 3) PRESTAINED WOOD STILES AND GLAZING STOP 3/8" TEMP. PLATE GLASS FURN. * INST. BY G.C. , CUSTOM DOOR PUSH /PULLS 22 FURN. BY TENANT INST. BY G.C. SURFACE BOLT #3538 -26D NOTE: *4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (FREHUNG) [P-1a3 "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.G. SEE SHEET 'A.2.12' FOR MORE DETAIL FINISH FLOOR LINE WOOD DOOR CASING CWD -Ia] CP -Ia] #5965 -26D 2 3/4" PASSAGE PUSH /PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S441A1 " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. STANDARD SATIN ALUMINUM HINGE (TYP. OF 2) 4BP6IPA5CHO STOCKROOM CLOSURE - (MOUNT ON INTERIOR OF DOOR USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) #TY37B4841N -26D DOOR VIEWER #155 DKB PERIMETER SEAL (2) 84 #(1)42' GENERAL NOTE: DOOR, FRAME AND HARDWARE FURN. BY TENANT, INST. BY G.G. S- LABEL SMOKE SEAL (MN. 20 MINUTE SMOKE RATING) -PEMK S44W " SILLICONSEAL' NOTE: #4041 -26 WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. t (TOILET ROOM DOOR- STOCK SIDE) 0 DOOR 3' -0" 31 0 11 EXIT FINISH #q8V DKB 42" FLOOR DOOR SWEEP LINE DOOR 3' -0' L _ -- DOOR (SERVICE DOOR - INTERIOR VIEW) NOTE: #4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. r � 4a (SERVICE DOOR - EXTERIOR VIEW) 0 NOTE: EXIT DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT. Q- 4 1/2" X 4 1/2" NRP PRIMECOAT HINGES (TYP. OF 3) 3/4 "x3 1/2" WOOD DOOR CASING [WD -1] CP -2] (TYP.) G.G. TO FURN. $ INSTALL H .C. $ M/F SIGNS W ITH CONTRASTING COLORS IN 8 " M ACCORDANCE WITH THE ADA H.C. SIGN IS TO BE BLUE ON WHITE #SPI76BSN -26 D PRIVACY 2 3/4 SET (G.C. MUST INSTALL W/ 2 3/3" BACKSET USING #V21g00 722 -26D LATCH) HOLLOW CORE WOOD (PREHUNG $ PREMACHINED) DOOR EP -2] UNDERCUT DOOR 1 1/2" FINISH FLOOR LINE EXIT SIGN FURN. BY TENANT INSTALLED BY G.C. HOLLOW METAL JAMB (PAINT TO MATCH MALL STANDARD) +FOLLOW METAL, 90 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) #P531 DOOR PULL *AL700 PANIC ALARM BAR S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) - PEMKO S44W "SILLICONSEAL" NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED HOLLOW METAL, 410 MINUTE FIRE RATED DOOR (PAINT TO MATCH MALL STANDARD) G.C. SHALL FURN 4 INST. SIGN OR STENCIL "AERIE SPACE NO. LANDLORD REQUIREMENTS. #DJPDF -161PC HOLE FILLER #DJEF -161PC EDGE FILLER (NOT SHOWN) #DJFA.1,12060PC FRAME FILLER (NOT SHOWN) �-- PUSHBUTTON -FURN. BY TENANT INSTALLED BY E.C. NOTE: EXISTING DOOR AND FRAME TO REMAIN - UPGRADE HARDWARE AS REQUIRED CUSTOM HANG BAR FURN. BY TENANT INST. BY G.C. #SP1I5BSN -26D PRIVACY 2 3/4" LEVER LOCKSET NOTE: 1#4041 -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL _ ADJACENT TO HINGES. DOOR BOLT To fn I co FINISH FLOOR L NE #BP6IPABCHO STOCKROOM - CLOSURE (MOUNT ON SALES SIDE USING PARALLEL ARM MOUNT $ SEX BOLTS FURN. BY TENANT) HEAVYWEIGHT BALL BEARING 4 1/2" X 4 1/2" -26D HINGE BEYOND (TYP OF 3) PRE- INSTALLED KICK PLATE 3/4 "x3 1/2" WOOD DOOR TRIM [WO -1a] [P -Ia] (TYP) o DOOR DOOR OPEN 3' DOOR (VESTIBULE OPENING) (INTERIOR FITTING ROOM DOOR VIEW) (COMPUTER ROOM DOOR - PUBLIC SIDE) FINISH FLOOR LINE NOTE: SEE DOOR JAMB DETAILS ON SHEET 'A.2_ga' FOR VARIOUS CONDITIONS - COORD. W/ FLOOR PLAN. WOOD POST CP -103 WOOD (PREHUNG 4 PREMACHINED) DOOR [P-1a3 3 1/2" X 3 1/2" -26D IT STANDARD HINGE (MIDDLE DOOR ONLY) m 3 1/2" X 3 1/2" -26D SPRING HINGES #RC1252 (TYP OF 2) (TOP AND BOTTOM ONLY) NOTE: 1:40q -26D WALL BUMPER TO BE INSTALLED ON PERPENDICULAR WALL ADJACENT TO HINGES. FIRE RATED DOOR (PREHUNG) [P -Ia] "EMPLOYEE ONLY" SIGN FURN. BY SIGN CONSULTANT, INST. BY G.C. SEE SHEET 'A.2.12' FOR MORE DETAIL WOOD DOOR CASING [ND -103 [P-1a3 #54165 -26D 2 3/4" PASSAGE PUSH/PULL (HOSPITAL SET) S -LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 944W " SILLICONSEAL" NOTE: G.C. SHALL ADJUST CLOSURE TO LIMIT OPENING FORCE TO (5) FIVE POUNDS. FINISH FLOOR LINE NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALP1- IABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. S- LABEL SMOKE SEAL (MIN. 20 MINUTE SMOKE RATING) -PEMKO 9441 " SILLICONSEAL" A.2.10 METAL DOOR KICK PLATE W/ EXPOSED BLACK OXIDE FASTENERS CM -1a] E DOOR STOP CWD -111] CP -la] B III A.2.10 I- IOLLOW METAL 16 GA. KD JAMB [P -Ia] STOCKROOM DOOR METAL STUD NAILER FURN. BY TENANT, INST. BY G.G. STANDARD DOOR JAMB CP -1a] DOOR STOP [P -la] TOILET ROOM DOOR 3/4 "x3 1/2" WOOD TRIM [ND -103 CP -1a3 (TYP. BOTH SIDES) FITTING ROOM DOOR METAL STUD NAILER - INST. FURN. BY BY G.C. TENANT, DOOR 00 DOOR JAMB DETAILS SCALE: 11/2" 1) 0,5 050 SCALE: 1" = I' - 0" DOOR 11 - 0 4 VESTIBULE STOCKROOM DOOR 1x4 WOOD TRIM CWD -la] CP -lo] METAL STUD NAILER DRYWALL 3 5/8" METAL STUD FRAMING 3/4 "x3 1/2" WOOD CASING [P -Ia] (TYP.) FITTING ROOM 1 11 4 [WD -2a] [P-1a3 3 5/8" METAL STUD FRAMING VESTIBULE MOUNTING HARDWARE FURN. BY TENANT, INST. BY G.C. 5/8" DRYWALL CP -2a] 5/8" DRYWALL PRIME ONLY REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 1 ?.006 City 0fTuI Ia BUILDING DIVISION DRYWALL CP -2a] Wst/leId Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual Field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir• . to be kept on the job site at a I l2$la7 Si•ned Date DOOR PLATE DETAILS RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER tO 0 0 0 01 MAME C6 -Ia] CP -103 CWD -2] CP - ta] SCALE: 1 t /2" 1 - 0" 3/4 "x2" WOOD TRIM [WD - la] CP -1] SCALE: 1 1/2" = 1' - 0" CB -1] CP -la] OF STANDARD PREFABRICATED "FAUX" DISPLAY CASE PILASTER CP -1a] (TYP.) ADJUSTABLE SHELVING SHOWN FOR REFERENCE VARIES SEE FLOOR PLAN CB -2a] CP -1] W PLAN SECTION @ "FAUX" ALL DISPLAY CASE 10 -0" A.F.F. CWD -la] CP -3a] PREFABRICATED DISPLAY CASE CAP ASSEMBLY CP -1] PREFABRICATED DISPLAY CASE ASSEMBLY, NON - ROUTED MDF CP -la] ADJUSTABLE SHELF ON WALL STANDARDS SHOWN FOR REFERENCE FINISHED FLOOR Cf.. OF STANDARD NON- ROUTED MDF (TYP.) SECTION T-OLJf- "FAUX" WALL DSFLAY CASE OF STANDARD CB -la] CP -la] CWD -2a] CP -la] CB -2] DETAIL @ "FAUX" WALL DISPLAY CASE NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPNASETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. SCALE: 1 1/2" = 11 - 0" FIELD CUT CWD -2a] PANEL AS REQUIRED SCALE: 1 1/2" a 1 1 - 0 " DETAIL @ "FAUX" WALL DISPLAY CASE _.+ _•vt��.� [3 -1a] CP -Ia] PREFAB. WING WALL ASSEMBLY WING WALL DETAIL G.C. SHALL INSTRUCT CONTRACTOR TO INSTALL STUDS AT PILASTER LOCATIONS FOR BOLTING PREFAB. PILASTER NAILERS INTO METAL STUDS. FACE OF ADJACENT PARTITION C8 -2a] EP-1a3 (TYP) C13-1a3 [P -1] (TT) PREFAB. ROOM DIVIDER BY MILLWORK SUPPLIER WITI - 3 A" DRYWALL CLADDING BY G.C. CP -43 ;HAMPERED CORNER BY )RYWALL INSTALLER TIP) WOOD TRIM CWD -la] CP -Sia] (TYP) CWD -2o3 CP -1 ] (TIP.) NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM $ WALL PRIOR TO PAINTING. 7 SUSPENDED CEILING SYSTEM a I i i i E I I I I 1 I E ! I pIp 1 i 1 I 1 I I 1 i I 1 1 1 1 1 f 1 i 1 1 3 ; I I 1 E 1 1 1 1 • i 1 ' i I E 1 1 1 1 1 i 1 I 1 1 1 I 1 1 f 1 1 I 1 I I 1 f I ( ! 1 1 1 1 i 1 l f 1 1 , 1 1 1 j i 1 � 1 1 1 , 1 ` I 1 1 1 1 f I i 1 € 1 1 I 1 I 1 1 1 f 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 i 1 1 1 1 1 1 1 1 1 1 pApG Rep 1 f 1 I i These dray 1 j C t i intent only. 1 1 1 1 verified by 1 1 i is responsi a q u , 1) to l 1 1 1 1 Si n I I i 1 1 1 1 I I 1 11 i 1 I ! I ( 1 1 1 1 1 1 1 i 1 j 1 I I CB -2o] [P -1a] [B -1] CP -la] PREFAB. WING WALL ASSEMBLY ELEVATION 11 -0' A.F.F. CWD -1a] CP -3a] 10 -0" AFL. q' -0" A.F.F. CWD -la] [P -3a] REE OMP� CE COD APPROVED MAR 2 1 2fl 1 CIS Tukwila BUILDING DWI ION Wstflek[ CWD -2a] CP -1a] (TYP.) Working Drawing Review roved roved as Noted submit vings have been reviewed for general design t All actual field conditions are required to be Q 1 the Tenant's Architect and/or Contractor. Tenant �J ble for complying with all government regulations. py of this landlord stamped set of drawings is be kept on the job site at a I /28/07 RECEIVED CITY OF TUKWILA FEB 0 4 7008 PERMIT CENTER im MAME C6 -Ia] CP -103 CWD -2] CP - ta] SCALE: 1 t /2" 1 - 0" 3/4 "x2" WOOD TRIM [WD - la] CP -1] SCALE: 1 1/2" = 1' - 0" CB -1] CP -la] OF STANDARD PREFABRICATED "FAUX" DISPLAY CASE PILASTER CP -1a] (TYP.) ADJUSTABLE SHELVING SHOWN FOR REFERENCE VARIES SEE FLOOR PLAN CB -2a] CP -1] W PLAN SECTION @ "FAUX" ALL DISPLAY CASE 10 -0" A.F.F. CWD -la] CP -3a] PREFABRICATED DISPLAY CASE CAP ASSEMBLY CP -1] PREFABRICATED DISPLAY CASE ASSEMBLY, NON - ROUTED MDF CP -la] ADJUSTABLE SHELF ON WALL STANDARDS SHOWN FOR REFERENCE FINISHED FLOOR Cf.. OF STANDARD NON- ROUTED MDF (TYP.) SECTION T-OLJf- "FAUX" WALL DSFLAY CASE OF STANDARD CB -la] CP -la] CWD -2a] CP -la] CB -2] DETAIL @ "FAUX" WALL DISPLAY CASE NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPNASETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. SCALE: 1 1/2" = 11 - 0" FIELD CUT CWD -2a] PANEL AS REQUIRED SCALE: 1 1/2" a 1 1 - 0 " DETAIL @ "FAUX" WALL DISPLAY CASE _.+ _•vt��.� [3 -1a] CP -Ia] PREFAB. WING WALL ASSEMBLY WING WALL DETAIL G.C. SHALL INSTRUCT CONTRACTOR TO INSTALL STUDS AT PILASTER LOCATIONS FOR BOLTING PREFAB. PILASTER NAILERS INTO METAL STUDS. FACE OF ADJACENT PARTITION C8 -2a] EP-1a3 (TYP) C13-1a3 [P -1] (TT) PREFAB. ROOM DIVIDER BY MILLWORK SUPPLIER WITI - 3 A" DRYWALL CLADDING BY G.C. CP -43 ;HAMPERED CORNER BY )RYWALL INSTALLER TIP) WOOD TRIM CWD -la] CP -Sia] (TYP) CWD -2o3 CP -1 ] (TIP.) NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM $ WALL PRIOR TO PAINTING. 7 SUSPENDED CEILING SYSTEM a I i i i E I I I I 1 I E ! I pIp 1 i 1 I 1 I I 1 i I 1 1 1 1 1 f 1 i 1 1 3 ; I I 1 E 1 1 1 1 • i 1 ' i I E 1 1 1 1 1 i 1 I 1 1 1 I 1 1 f 1 1 I 1 I I 1 f I ( ! 1 1 1 1 i 1 l f 1 1 , 1 1 1 j i 1 � 1 1 1 , 1 ` I 1 1 1 1 f I i 1 € 1 1 I 1 I 1 1 1 f 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 i 1 1 1 1 1 1 1 1 1 1 pApG Rep 1 f 1 I i These dray 1 j C t i intent only. 1 1 1 1 verified by 1 1 i is responsi a q u , 1) to l 1 1 1 1 Si n I I i 1 1 1 1 I I 1 11 i 1 I ! I ( 1 1 1 1 1 1 1 i 1 j 1 I I CB -2o] [P -1a] [B -1] CP -la] PREFAB. WING WALL ASSEMBLY ELEVATION 11 -0' A.F.F. CWD -1a] CP -3a] 10 -0" AFL. q' -0" A.F.F. CWD -la] [P -3a] REE OMP� CE COD APPROVED MAR 2 1 2fl 1 CIS Tukwila BUILDING DWI ION Wstflek[ CWD -2a] CP -1a] (TYP.) Working Drawing Review roved roved as Noted submit vings have been reviewed for general design t All actual field conditions are required to be Q 1 the Tenant's Architect and/or Contractor. Tenant �J ble for complying with all government regulations. py of this landlord stamped set of drawings is be kept on the job site at a I /28/07 RECEIVED CITY OF TUKWILA FEB 0 4 7008 PERMIT CENTER ENNUI Al2.1 la 11'_0" A.F.F. CEILING PANEL - MDF N/ ROUTED PATTERN FURN BY TENANT INST. BY G.C. DRYWALL EP-4a] (TYP.) HOOD TRIM CND -1a] EP-1a] (TYP.) WOOD POST [WD -1a] [F -1a] CO -2a] [P -Ia] CB -la] CP -Ia] A.2.I1a SUSPENDED CEILING SYSTEM A.2.11a SCALE: 1 1/2" • DRYWALL CP -3a] (TYP.) LIGHT FIXTURE FURN. BY TENANT INST. BY E.C. i II 5USPENDED CEI SYSTEM ' - 0" A.F.F. t o SECTION T-ROU TRANSOM WALL DISPLAY A.2.IIa C8 -20] CP -1a] CS -1a3 CP -1a] 2x WOOD BLOCKING CHAMFER (TYP.) WOOD POST CWD -la] CP -Ia] DISPLAY CASE OST DETAIL NOTE: PAINTING CONTRACTOR SHALL CAULK ALL INSIDE WOOD CORNERS AND JOINTS BETWEEN TRIM $ WALL PRIOR TO PAINTING. REVIEWED FOR :. CODE COMPLIANCE APPROV 4 R 21 2.008 C +Ib' D TukWlla BUILDING DIVISION Wsffle/[ Working Drawing Review Approved Approved as Noted © Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One Cl) copy of this landlord stamped set of drawings is required to r be kept on the Job site at a I � Si ned D ate NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY NAVE !FEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. ECEIVED CITY OF TUKWILA FEB B4 ?PA PERMIT CENTER CUSTOM "AERIE" FONT i" THICK CAST RESIN LETTERS PREFINISHED CUSTOM "NEWBURGH" FONT LASER CUT 1/2" THICK ACRYLIC LETTERS PREFrINISHED BRUSHED COLD — ROLLED STEEL PLAQUE FURN BY SIGN CONSULTANT INST. BY G.C. METAL STOREFRONT PLAQUE SIGN SHALL 8E ATTACHED TO WOOD PANEL WITH (4) PAN HEAD SQUARE DRIVE WOOD SCREWS FINISHED TO MATCH PLAQUE 6 f ' MOUNTING SURFACE — LETTERS SHALL BE MOUNTED FLUSH. CUSTOM "AERIE" FONT i" T CAST RESIN LETTERS PREFINISHED CUSTOM "NEWBURGH" FONT LASER CUT 1/2" THICK ACRYLIC LETTERS PREFINISHED .125 ETCHED ZINC PLATE BLACK BACKGROUND BRUSHED SILVER SURFACE MATTE CLEAR FINISI -I MOUNT WITH (4) STAINLESS STEEL MACHINE SCREWS. E: DETAILS, NOTES, AND /OR SPECIFICATIONS ON HIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. Graphics appted directly to the storefront glass must ti,rii e matching letters and features on both side of glass b ante a finished took when viewed from either side. Maximum leer height of letters is u ) DECAL — FACE ADHESIVE, WHITE VINYL. APPLIED TO 'STORE SIDE' OF DISPLAY WINDOW GLASS. Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect andfor Contractor. Tenant Is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir to be kept on the job site at a I /2 8/07 RECEIVED CITY OF TUKWILA FEB 64 K ~A PERMIT CENTER DYER SIGNS iNC. Avenue Columbus, SIGNS„, 43207 (614) 443 - 8500 443 -4809 mdhanover @aol,com SWAM NEM O j: O SQUARE FOOTAGE AREA SQ. FT. SALES AREA 5,040 75 FITTING ROOM 433 11 STOCK ROOM 284 7 TOILET ROOM(S) 63 2 EXIT CORRIDOR 141 3 COMPUTER CLOSET q8 2 TOTAL 4, O 100% attigg PIE EMIENSVZ 4' -0" x 2' -0' SENCH FURN. BY TENANT, INST. BY G.C. SEE DETAILS ON SI -IEET 1 A.2.q' ANTI -TIP BRACKET FOR STOCK SHELVING FURNISHED 8Y TENANT, INSTALLED BY G.C. STOCK SHELVING (MOI FIXED) FURN. BY INSTALLED BY DETAILS F /F.0.2, H /F.o. ILE AND TENANT, x.C. SEE i /F.0.2 $ (TYP.) PEGBOARD PANEL- FURN. BY TENANT, INST. BY G.C. SEE DETAIL A/F.0.1 (TYP.) V ---\-- - i' u PEGBOARD PANEL - FURN. VI BY TENANT, INST. BY G.C. (INSTALL PER CUT -OUTS FOR SHELVING HANDLES) u I= 3' X 5' OVAL POUF. FURNISHED BY TENANT INST BY G.C. e4L'�.:s7�*r�"cr�gx��. _2�4��vcrv � ' !'�5;.� — �"- Rmey��rarn�w�"�.�t� - +fie �ai-a,Y:7s:r.�Xr.Rer.4aR��� !iw� "".eT: €`ar:°:sYrt `"- ".3= m;•a -- -.:F 1rct`53�"- 5a 3 -WAY MIRROR 4 PREFAB. "ANGLED" WALL ASSEMBLY. SEE DETAILS ON SHEET ' A.2.q ' (TYP.) 15" DIA. FITTING ROOM POUF, FURN. BY TENANT, PLACED BY G.C. (TYP. OF 2 PER ROOM) CONTINUOUS CURTAIN ROD - MOUNTED. W/ BRACKETS TO FACE OF FITTING ROOM HEADERS /TRIM - FURN. INST. BY G.C. (TYP. OF 2) LADDER HANG BRACKET - FURN. BY TENANT, INST. BY G.C. 86 " -88" A.F.F. (TYP OF 2) HANG BAR STORAGE CABINET FURN. BY TENANT INST. BY G.C. EMPLOYEE LOCKERS FURN. 8Y TENANT INST. BY G.C. (TYP) PREFAB_ "BACK WRAP" COMPONENTS. SEE SI.4EET 'F.2.2' FOR MORE INFORMATION. PREFABRICATED "LEANING" MIRROR FURN. BY TENANT, INST. BY G.C. (SIM TO DET. E /F -4 * F /F -4) (TYP OF 2) NOTE: ALL SHELVING SHALL BE IO' -0" A.F.F. VANITY FURNISHED BY TENANT, PLACED BY G.G. OVAL MIRROR FURNISHED BY TENANT, PLACED BY G.C. ��. w. w. w, w. tixw .w.wwv.w,whrw.w.w,w.y�tar.w.w PEGBOARD PANELS FURN. BY MILLWORK SUPPLIER INSTALLED BY G.G. SEE FLOOR PLAN FOR LOCATIONS FLOOR EXISTING WALL SURFACE PEGBOARD DETAIL COMPUTER CABINET - FURN. BY TENANT, INST. BY G.G. - SEE DETAIL A/E.0.2 AND CABINET ISOMETRIC DETAIL A/F.0.2 SURFACE MOUNTED 1 X 3 FLOOR SLEEPERS FURN. BY FLOORING SUPPLIER INST. BY G.G. CONTINUOUS f TOP, MIDDLE AND BOTTOM OF PEGBOARD Ulu G.C. SHALL FURNISH AND INSTALL 3/4 "x4'x4' NON -COM PLYWOOD BACKER BOARD AT 6' -0' ABOVE CONCRETE SLAB. TO BOTTOM FOR AUDIOVISUAL SYSTEM BY AUDIOVISUAL CONSULTANT. SEE DETAIL A/E.0.2 AND CABINET ISOMETRIC DETAIL A/F.0.2. 0 FIXTURE PLAN RECEIVED CITY OF TUKWIL4 FEB 0 4 2008 PERMIT CENTER EMDEN RENEWS A(J?1diri11 rag Eis _. -_ -,:•; ��:;=,--;= r�: �� :•wY_x:�:- _��.�:: >�.� >.a -,. - -_ :_:rte;, m F4 N M q a 7r7 LL MOM ORE BESECESIEMISE i!1 0 04 C 7751 Drawing No. F,0.1 iiimisfamsass DiEZPEEMENI t� 3/4" X 3/4" NON -COM PLYWOOD BACKER BOARD AT 6' -0" ABOVE CONCRETE SLAB. - BY G.C. AUDIOVISUAL SYSTEM BY AUDI CONSULTANT MOUNTED 6' -3" ABOVE CONCRETE SLAB. 2 X 4 NON- COMBUSTIBLE WOOD CLEATS ((TOP AND BOTTOM) BY G.C. G.C. SHALL SECURELY FASTEN COMPUTER CABINET TO CLEATS. PREFABRICATED COMPUTER CABINET FURNISHED BY TENANT, INSTALLED BY G.C. NO SCALE I /4" X 2 HAMMER DRIVE ANCHORS SPLICE TRACK ANCHOR AT END AND AT SPLICE- (2)/TRACK STAGGER TRACK SPLICE + INSERT SPLICE. COMPUTER CA 3I NET l4 I T1 MOBILE CARRIAGE UNIT n END STOP :DETAIL 0 '% NO SCALE FIXED SHELVING UNIT SHELF UNIT KEY TYPE SIZE CAPACITY C 36" X 16" DOUBLE BAR N/ to SHELVES Ci 48" X 16" DOUBLE BAR N/ 6 SHELVES D 36" X 16" SINGLE 8AR W/ S SHELVES DI 48" X 16" SINGLE BAR W/ 8 SHELVES MOBILE CARRIAGE UNIT MCSILE CARRIAGE UNIT KEY TYPE SIZE MC -I 32 1/4" X 37" MC -2 32 1/4" X 4q" MC -3 32 1/4" X 73" MC -4 32 1/4" X 85" MC -5 32 1/4" X q7" EXAMPLE: NOTE: SHELF INSTALLATION INSTRUCTIONS AND DIMENSIONS ARE TYPICAL FOR A SHELF HEIGHT OF 120 ". SEE SHEET 'F - I' FOR ACTUALL SHELVING HEIGHTS AND ADJUST SHELVING INSTALLATION ACCORDINGLY. NO SCALE L_, ■ 1 'enItir%1r9M4h 10 - l. 1 1%/ r.; I TI [STEP #1 CARRIAGE TRACK THE ANTI -TIP ANGLE FACING TOWARDS WALL. PLACE Z -RAIL OVER THE ANTI -TIP ANGLE WITH A MAXIMUM CLEARANCE OF I /2" BETWEEN PIECES AS SHOWN. 1/8" X 1" X I" X 3 LONG STEEL ANTI- TIP ANGLE WELDED TO MOVING TRAY PLACE PERIMETER TRACK ON FLOOR WITH A MINIMUM DISTANCE OF 2 I /2" BETWEEN EDGE OF TRACK AND WALL /FIXED SHELF. (ANCHOR WITH I /4" X 2" HAMMER DRIVES) EXISTING / RELOCATED FIXED SHELVING UNIT st MOBILE SHELVING UNIT I STEP 4g2I C SERIES 1- INSTALL TRACK PER MANUFACTURER'S INSTRUCTIONS. TRACK MUST BE LEVEL (USING SHIMS AS REQ'D.) TO INSURE PROPER OPERATION. MAINTAIN 2" MINIMUM CLEARANCE BETWEEN EDGE OF TRACK AND WALL. 2. INSTALL SHELF UNITS ON MOBILE CARRIAGE. SHELF UNIT MUST BE SECURED TO UNDER CARRIAGE USING ONE TEK SCREW IN EACH CORNER. . INSTALL BRAKES ON ALL MOVEABLE CARRIAGES PER MANUFACTURER'S INSTRUCTIONS. 4. DOUBLE X BRACES ARE REQUIRED ON MOBILE UNITS ONLY. FIXED UNITS REQUIRE SINGLE 'X' BRACE. 5 . INSTALL TWO BUMPERS BETWEEN EACH MOBILE UNIT 71 1/2" FROM BOTTOM IN PREDRILLED HOLES. 6_ THESE SHELVES TO BE PERMANENTLY FASTENED IN PLACE USING TWO TEK SCREWS AT EACH END THRU CROSS RAIL. 7_ ALL BACK TO BACK SHELF UNITS MUST BE FASTENED TOGETHER USING AT LEAST FOUR TEK SCREWS PER VERTICAL UPRIGHT. 8. ATTACH HANDLE 44" A.F.F. +/- TO CENTER ON MOBILE UNITS ONLY. NOTE: CONTRACTOR TO CONSULT TENANT ONSITE CONSTRUCTION REPRESENTATIVE REGARDING PLACEMENT OF WARNING PLACARDS. CARRIAGE SECTION ANTI -TIP DETAIL SEE NOTE #6 HANG BAR SEE NOTE #5 SEE NOTE #4 SEE NOTE #6 SHELF INSTALLATION NOTES WALL OR FIXED SHELF I/8" X 1" X 2 -I /4 I" STEEL Z -RAIL SECURED TO SLAB W/ 1/4" X 2" HAMMER DRIVE ANCHORS 6 12" O.C. D SERIES SEE NOTE #6 14ANG BAR SEE NOTE #5 SEE NOTE #4 "S/EE NOTE #8 SEE NOTE #6 NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTE AND DO NOT PERTAIN TO THIS PROJECT. Permit is wire for all storage, racks more than 5 ' 1 ' in height. Stml ent r Plan submittal Checklist No rack storage is atImed 17-0" or higtier. Verify Fire Marshall whether side shdirici stock MOM Shelving will be .. since Fire Protection Landlord's sprinkler system is, designed for Ordinary Hazard Gpatip 2 a Sidned Wslfie[t[ Working Drawing Review y( Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is RECEIVED requir� j to be kept the jo a I im212 8/67 OF TUII/I N) T E: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. • L < iza I ci U 4-- . -) U : U) 1- • PREFABRICATED METAL COVE FRAME By OTHERS SCALE: 1 " =1' -0" SUPPORT STRAPS WELDED TO REMOVABLE FRAME 1/4" POLISHED PLATE GLASS MIRROR. PRE- INSTALLED BY OTHERS. PREFABRICATED MIRROR DETAIL "LEANING" MIRROR BRACKET FURN. BY TENANT, INST. BY G.C. SEE DET. F /F.0.2. SCALE: I" =I' -O" PREFABRICATED MIRROR W/ FRAME FURN. BY TENANT INST. BY G.C. 1/4" LAG SCREW BY G.C. THRU MIRROR FRAME INTO FLOORING. 'LEANING' MIRROR SECTION SECTION SCALE: 3" n1' -0" 3/16" THICK HOT ROLLED STEEL PLATE. FURN. BY TENANT INST. BY G.G. ISOMETRIC Westlle[d Si.ned Date Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir • to r be kept on the job site at a I NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE SEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. REAR OF STORE IP PHONE LINE BEHIND PANEL PRE - MOUNTED "ORANGE' DEDICATED DUPLEX RECEPTACLE - E.C. TO WIRE (TYP) VOLUME CONTROLS REMOVABLE WOOD PANEL NOTE: CASH REGISTER DESIGNATIONS ARE FOR SCHEMATIC PURPOSES ONLY. COORDINATE WITH TENANT REP. FOR ACTUAL NUMBER $ CONFIGURATION_ PRE- MOUNTED DEVICE E.C. TO WIRE (TYP) PRE - MOUNTED "ORANGE" DEDICATED DUPLEX RECEPTACLE BEHIND PANEL. E.C. TO WIRE (TYP) ins, FRONT ELEVATION -FRONT COUNTER PRE - MOUNTED DEVICE E.C. TO WIRE (TYP) 16' -4" PRE - MOUNTED DEVICE INSIDE OF WALL CABINET E.C. TO WIRE (TYP) - PIGTAIL WIRE THRU WALL AT 408" HIGH STOR PHONE LINE PANEL INTIMATES CASH * WRAP - FRONT WRAP - FRONT ELEVATION IP PHONE LINE NOTE: PROVIDE SEPARATE NEUTRAL AND DEDICATED ISOLATED GROUND CONDUCTORS FOR CIRCUIT LB -6 CASH REGISTER AND ELECTRONICS EQUIPMENT. PLAN VIEW -FRONT AND BACK COUNTER REAR OF STORE 1 i i } ' 5 � E.t. MALL INSTALL J ; BO ES FOR POWER, . , AUDIO, DATA PHONE. REMOVABLE WOOD PANEL REGISTER ENCLOSURE (TYP). NOTE: STORE PHONE LINE, VOLUME CONTROLS, $ IP PHONE LINE ARE SHOWN FOR SCHEMATIC PURPOSES ONLY. COORDINATE WITH TENANT REP. FOR ACTUAL INSTALLATION LOCATIONS. ~-BRUSHED NICKEL ROUND KNOBS, (TYP). WOOD LEGS $ FRAME RECESSED TOE KICK BEYOND TAPERED ROUND WOOD POST BASE SCALE: 3/4" G I' _ 0' SIDE ELEVATION VOID WIRE CHASE AREA PULLOUT WORK SURFACE REMOVABLE WOOD PANEL VOID - WIRE CHASE AREA CABINET SIDE PANEL ite REMOVABLE WOOD PANEL SECTION SCALE: 3/4" = I - 0" INTERIOR ELEVATION -FRONT COUNTER rod Go v, = P _o STAINED CHERRY WOOD COUNTERTOP VOID - WIRE CHASE AREA rrr_rrr�r�rrrrrrrr>>r -rrr rr.:s :rrr PRE - MOUNTED DOUBLE DUPLEX RECEPTACLE LOCATED IN BACK OF CABINET. E.C. TO WIRE (TYP) REAR OF STORE (3) J -BOX'S CONDUIT SUPPLIED 4 INSTALLED BY E.G. brawi _ . :.__ RECEIVED CITY OF TUKWILA FEB B 4 2003 PERMIT CENTER Wsifleid Working Drawing Review Vz Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant Is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir lobe kept on the Si•ned Date NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 1 ,; . ,.F�, WOOD SHELF SUPPORTED BY CUSTOM WALL BRACKET r -- 1 0 0 �;_ __..J r, o EQUAL VOLUME CONTROLS STD SAFE DRYWALL WITH PLYWOOD BACKING EQU 16 -4 EQUAL rl — I) SCREW BRACKET TO PLYWOOD COVERED WALL 2) COVER BRACKET WITH DRYWALL PRE - MOUNTED D UPLEX RECEPTICLE LOCATED IN SIDE OF CABINET. E.C. SHALL WIRE (TYP.) WHIP T1 WALL n FRONT ELEVATION -REAR COUNTER WALL GARBAGE CAN FLIPPER DOOR Mr PREFAB. CEILING PLANK ASSEMBLY. SEE DETAILS ON SHEET 'A.2.8' SUSPENDED CEILING SYSTE 2 PIECE PREFAB. VALANCE ASSEMBLY (TYP) (ASSEMBLE IN FIELD 4 ADJUST TO ACCOMODATE FLOOR CONDITIONS) WOOD FRAME CONSTRUCTION (TYP) CHERRY WOOD SHELF PRE- MOUNTED DUPLE( RECEPTACLE LOCATED IN BACK OF CABINET. E.C. TO WIRE (TYP) STAINED CHERRY WOOD COUNTERTOP (3) J -80X 4 CONDUIT SUPPLIED * INSTALLED BY E.C. ELECTRICAL OUTLET SIDE OF CABINET (TYP) 48" FLOURESCENT LIGHT, MOUNTED TO CEILING ® CENTER OF CASH /WRAP NOTE: THIS DRAWING IS FOR SCHEMATIC PURPOSES ONLY. COORDINATE INSTALLATION WITH FLOOR PLAN, CEILING PLAN, ELEVATIONS, 4 ACTUAL COMPONENTS PROVIDED BY MILLWORK _ SUPPLIER. SHELF BRACKET DETAIL SCALE: NTS METAL STUD I/2" PLYWOOD HOLES FOR BRACKET GYPSUM BOARD RECEIVED CITY OF TUF<WILA = FEB B 4 2008 L PERMIT CENTER Westf Working Drawing Review v Approved _ Approved as Noted ❑ Resubmit These drawings have been reviewed for general design . Intent only. All actual field conditions are required to be S � verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir -. tope kept on the job site at a I /28/07 SI ned Date NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. -VOID AREA IN CORNER J BOX ON BACK WALL (CONNECT DAYBED CAN LIG,I -ITS) 3 - 3 n BLOCKING IN WALL (tYp) PRECUT HOLE; ELECTRICIAN TO SUPPLY 4 INSTALL SGL DUPLEX OUTLET WITH WHITE COVER FINISHED CABINET CEILING PANEL (BEADED FINISHED UNDERSIDE) ARCH VALANCE CONNECTS CABINETS .3 SCALE: 1" a I ' _ 0" LIGI- 1TOLIER RECECESSED CAN LIGI -{T #303MRE, WITH WHITE TRIM #3131.4HX AND BULB #MR16 (typ) PREFABRICATED "DAYBED" PLAN In /VOID AREA IN CORNER AYBED SEATING AREA FABRIC COVERED CUSHION 0 1 1 4 31 — '" Si•ned 11' -5611 21 _C" SCALE: I" 1' - 0" Ws1/le[ct Working Drawing Review flc Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir to be kept on the job site at a I /2Si07 Date NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SI -IFET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE SEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 4 -7R" SIDE TALL CABINET 4 CURVED CHEERY WOOD TOP (typ 2) PREFABRICATED "DAYBED' SECTION STACKED TRIM TYPICAL -n 4n In 4 SECTION 'A' 1) - dam LIGHTOLIER RECECESSED CAN LIGHT #503MRE, WITH WHITE TRIM #313WHX AND BULB #MRI6 (typ) NOTES 5 4" MDF CORE, BEAD 2" CENTER, CABINET CONSTRUCTION 1/2" BALTIC BIRCH VENEER PLYWOOD CORE DRAWER 50X, y" PLYWOOD BOTTOM POPLAR SOLID WOOD TRIM Y" ROUND MOLDING DETAILS CHERRY WOOD CURVED TOP, AERIE CHERRY STAIN, CLEAR FINISH CHERRY TOP SHELF SUPPORT HAFELE #282.73.725 (300 -423 -3531) 5 /4 11 MDF DRAWER FRONTS AND DOOR PAINT ALL SURFACES MATCH SHERWIN WILLIAMS COTTON WHITE #SW7104 SEMI GLOSS 2 COATS, PLUS PRIMER Y" CLEAR TEMPERED) GLASS DRAWER INSERTS AND TOP COLD ROLLED STEEL., BRUSH 80 GRIT FINISH, CLEAN GRIND WELDS, NO HEAT MARKS CLEAR TCI #LG CLEAR. 8200 -00, FLAT CLEAR KNOB BALDWIN #4702 -I50 Y4" BRUSHED NICKEL FINISH K $ V SLIDES, FULL D:TENSION 100L13 TILTOUT BIN HINGE, NON MORTISE BUTT HINGE DOOR HINGE, 120 CONCEALED SECTION 1 3 1 SCREW VALANCE DOWN THRU CEILING PANEL. PIN NAIL FROM BEHIND. FILL HOLES AND PAINT. 1 LOWER DRAWER STORAGE AREA CABINET TOP PANEL METAL WANG BAR BEADED BACK PANEL it WOOD PERIMETER TRIM SHIPPED LOOSE MOUNT METAL HANG BAR (typ 5) III I II PICTURE FRAME HANGING SYSTEM 1 1 1 1 MILLWORK BEADED PANELS (typ3) SHIPPED LOOSE APPLY PERIMETER TRIM H I • DAYBED ANGLED BACK ill 111 1 DAYBED SEATING TOP WOOD TRIM HANG BAR DETAIL SCALE: NTS I 1 citv of - Tukwila BU S.oxi4G oivisoN SECTION 'C' CITY of TUKWILA FEB B 4 2003 PERMIT CENTER REMOVABLE DAYBED DRAWER UNIT ON CASTERS, FINISH FLOOR AND LEVEL AS NEEDED .2.3 �Tl NOTES % MDF CORE, BEAD 2" CENTER, CABINET CONSTRUCTION 1/2" BALTIC BIRCH VENEER PLYWOOD CORE DRAWER BOX, Yq" PLYWOOD BOTTOM POPLAR SOLID WOOD TRIM Y2" ROUND MOLDING DETAILS CHERRY WOOD CURVED TOP, AERIE CHERRY STAIN, CLEAR FINISH CHERRY TOP 51-1ELF SUPPORT HAFELE #282.73.725 (SOO- 423 -3531) MDF DRAWER FRONTS AND DOOR PAINT ALL SURFACES MATCH SI- IERWIN WILLIAMS COTTON WHITE #SW7104 SEMI GLOSS 2 COATS, PLUS PRIMER Y4 CLEAR TEMPERED GLASS DRAWER INSERTS AND TOP COLD ROLLED STEEL, BRUSH 80 GRIT FINISH, CLEAN GRIND WELDS, NO HEAT MARKS CLEAR TCI #LG CLEAR 8200 -00, FLAT CLEAR KNOB BALDWIN 1*4702 -150 3,4 BRUSHED NICKEL FINISH K $ V SLIDES, FULL INTENSION 100118 TILTOUT BIN HINGE, NON MORTISE BUTT HINGE DOOR HINGE, 120 CONCEALED 1 '1711111111 4 1 -7 5" 4 -7a" SCALE: 3/4 = 2 1 -0 1 2 1 - 11' - 3811 " J BOX ON BACK WALL (CONNECT DAYBED CAN LIGHTS AND DUPLEX OUTLET) A PREFABRICATED ''DAYBED'' ELEVATION .2. 1 1 1 - -8 1V 0 4 -2 4 ' " =ry 1 1 CI PREFABRICATED "DAYBED" ELEVATION SCALE: 3/4" = 1 - 0" Kr Tr LIGHTOLIER REGECESSED CAN LIGHT #303MRE, WITH WHITE TRIM #313W14X AND BULB #MRI6 (typ) BASE 4 SHOE SHIPPED SEPARATELY WITH STORE MILLWORK PACKAGE ELECTRICIAN TO SUPPLY $ INSTALL %L DUPLEX OUTLET WITI -I WHITE COVER PULLOUT DRAWER ON SLIDES MILLWORK BEADED PANELS (typ 3) APPLY 1 "x1 PERIMETER TRIM (typ 6 pieces DAYBED ANGLED BACK DAYBED SEATING AREA (FABRIC COVERED CUSHION, NOT SHOWN) REMOVABLE DAYBED DRAWER UNIT ON CASTERS, FINISH AND LEVEL FLOOR AS NEEDED 1 DAYBED PERSPECTIVE DETAIL SCALE: NTS S O6O FINISHED CABINET CEILING PANEL (BEADED FINISHED UNDERSIDE) ARCH VALANCE CONNECTS CABINETS TRIM TO EXTEND TO WALL • z REMOVABLE DAYBED CURVED GLASS TOP, DRAWER UNIT AND BASE (TYP2) e\Neo CODt. COtek..10 WOO 0 Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant Is responsible for comptying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir -, to be kept on the job site at a I r Si•ned Date CIT RECEIVED UKWILA W e s/fie FEB c 4 2003 Working Drawing Revieew Approved r2128/07 NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPS- IASETICALLY DR NUMERICALLY 1-IAVE SEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO TI-IIS PROJECT. E -ir , Tyr % 5 o ,:st 1391 ir-T4 1a �oe/1 z o f moo, 1;4 Ch fr 7751 Drawn. by: g fuka M k' NOTE: ALL SHELVING SHALL BE IO' -O" A.F.F. D O O D O D D O O NOTE: CONTRACTOR SHALL VERIFY COMPLIANCE WITH SECTION 1006 OF THE INTERNATIONAL BUILDING CODE FOR EMERGENCY LIGHTING, SEE SHEET E.0.1 FOR LOCATIONS OF EMERGENCY LIGHTS. EGRESS PLAN MAR 0 5 2008 PERMIT CENTER FEB X 9 2003 STATE OF NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO T1-119 PROJECT. 1 4P :i. t t 0 z z '' V ■ E s 0 r 10 = t.1) 4° lj. xF n .f 3s Diming No. MS.O.1 IR Gi. II. GEjyERAI MECHANICAL TRADES SPECIFICATION FOR HEATING, VENTILATING, AIR CONDITIONING, AND FIRE PROTECTION NOTE: The Mechanical Trades Specification i5 divided Into two prate: I. SUPPLEMENTAL MECHANICAL TRADES SPECIFICATION defining the scope of work and the special requirements and agreement for this project; II. GENERAL MECHANICAL TRADES SPECIFICATION defining the standard reguirements and materials. If the Supplemental Specification le not attached, contact Tenant's irrmediatety. All work included under this heading is to be subject to the Instructions toSidders and General and Special Conditions herein before written :or referred to for the entire work. This Contractor shall furnish all labor cod materials, and install all equipment as called for in these specifications, the Supplemental Specifications, and shoun an the plans, cr as may be reasonably implied by either, for the installation of the complete heating, ventilating, air conditioning, plumbing, and fire protection systems. Refer to the Supplemental Mechanical Specification for the scope of this project. This Contractor shall, at his own expense, obtain all necessary permits and licenses and perform all work in strict compliance with applicable codes, including but not limited to: BOCA, UBC, UMC, UPC, SBCCI, federal codes, state codes, local codes, ADA, ATBCB, OSHA, NFPA, rd Life Safety Code, all of current issue. All work shall meet the requirements of 1oca1 utility companies. (d) All equipment shall be approved and labeled by appropriate industry testing agencies, including but not limited to Underwriters Laboratories, AGA, Factory Mutual, etc. All work and equipment shall be sized and installed in accordance with appropriate industry standards organizations including but not limited to ASHRAE, SMACNA, NSF, AEI, NEC, AAABC, AEE, ANSI, ARI ect. All work shall comply with the regptrements of the Landlord. Should an y change in the plans and speciFicatiane be repaired to conform to these ordinances and rewirenents, the Contractor shall notify the Tared at the time of submitting his bid. After entering into centrxt, the Contractor will be held to complete all work necessary to meet all regpirernents without extra expense to tine Owner. (h) All equipment shall be installed in strict accordgnce with the manufacturers' instructions and/or recorrmendatians, and goad industry Standards. If there is a corfltct, contact the Tenant's representative immediately. 42. D(AMINATION OF PREMISES (a) Before submitting proposals for the work, each bidder shall be held to have examined the premises and satisfied himself as to the existing conditions under which he will be obliged to operate in performing his part of the work. (b) No extras will be allowed the Contractor on Gement of his failure to make the above examination or neglect to include all labor end materials required to =melds the work- GENERAL ork GENERAL (a) (b) (c) (e) (f) (e) 43. CHASES AND RECESSES (a) All chases and recesses For pipes in new walls co shown an the plains or as repaired by this Contractor for the accarrmodation of his work will be provided by the Architectural Trades Contractor, but this Contractor shall be responsible for the accurate location of same. G4. CUTTING Awl D PATCING (a) All cutting and patching that may be necessary for the installation of the systems specified shall be done and repaired by this Contrmtor under the direction and to the satisfaction of Tenant's Construction Departrnner t. (b) No cutting of structural work shall be donne without the written consent of the Tenant being previously obtained in each ease and all such work shall be done in accordance with Tenant's Construction Department's direction and under its supervision. G5_ EXCAVATING AND BACKFILLING (a) This Contractor shall da all necessary excavating and baekfilling in carnation with his work. In backfilling, the earth must be tamped in layers of no more than 6" or flushed solidly in place. Where pipes pass over column footings cr are laid in filled ground, or in other ewes where Found necessary, they shall be supported by brick piers or other supports placed under the pipes e d carried down to a firm bearing. (b) All backfilliing shall be with sold fill, tamped as above. (c) All shall met with the approval of Tenant's Castructian Department. G6. DAMAGE TO OTHER WORK (a) This Contractor will be held responsible for all damage to other work caused by his work or through neglect on the part of his workmen. All patching aid repairing of damaged work will be done by the Contractor who installed the work, as directed by Tenant's Construction Department, but the cost of sae shall be paid by this Contractor. G7. SHOP DRAWINGS (a) After the contract is awarded, this Contractor shall subunit to Tenant's Construction Department six prints or six folders of all plumbing fixtures, all I4VAC equiprrrent, sprinkler shop drawings, and cuts en miecellanecus equipment. Approval of the shop drawings or folders shall cover design or detail only, and shall not be construed as a check upon the sane. Such approval shall neither relieve the Contractor from this responsibility for proper construction and accuracy of measwernente nor From the necessity of fumishtng the labor and the materials rewired by the original speciFicatios and drawings but not shown on said shwp drawings or folders when approved. Upon completion of the job, this Contractor shall deliver to Tenant's Construction Department a complete set of approved shop drawings and Landlord approved sprinkler drawings. G8. ACCESS PANELS (a) Furnish to the Architectural Trades Contractor, For installatian by him, Bar -Co metal panels, Type 300, 400 or 500 as required. Locations as required For access to dampers, valves, controls, cleanouts, etc., furnished by this Contractor and installed above ceiling or in furred spaces. The access panels shall be of sufficient size so that all ecelpnent will be completely serviceable. The access panels shall have the same fire rating as the ceilings in which they are installed. (b) Access panels are not rewired in lay - type ceilings. Gq. &"SERI (a) All materials shall be new and the best of their respective kinds, and shall conform to all standard5 cr regnirernents gemming the same, and shall be ceprmYed by Tenant's Construe-tier& Department before being installed. (b) Where specific manufacturer err trade name is mentioned in the specifications, it is tb establish a standard of quality. Substitution of other makes that may be judged awl by Tena'nt's Construction Department may be made only by its authority in writing, and must be made prior to time of bid. (c) All materials shall be in accordance with code receilrements and as follows: (b) (c) GIO. DAMPERS AND FIRE DAMPERS (a) Famish and install drapers or splitters at all branch take -off and opposed blade volume dampers at all maims and sub -mains and where called for on the drawings. All dampers cr splitters shall be sufficiently stiffened to prevent noise or vibration and in no case shall be lighter than #18 gauge iron and shall be Fitted with an accessible adjuster, by Young Regulator Co., Parker Ceylon Carp., cr approved equal. Furnish and install weighted fire dampers In ducts held open by fusible links in location as indicated on plans and rewire by code. Dampers shall be labeled by Underwriter's Laboratories. Provide slide access doer adjacent to all dampers err splitters and adjacent to all fusible lines except where they are located in ceiling _diffusers with removable cores. GI1. SHEET METAL. DUCT AND FUMBLE DUCT (a) All sheet metal ductw c rlc shall be constructed and installed in accordance with the latest standards of ASHRAE, SMACNA Standards, NFPA 90 A, NFPA 908, and all other applicable codes. See ' SMACNA 14VAC Duct Construction Standards' applicable tables. Except where rated far VAV systems, all ductwork for air conditioning systems, toilet exhaust systems, ventilatian systems and exhaust systems shall be of galvanized steel and far low pressure duct cunatructicn. (c) Low Pressure Ductwork (c -I) All rectangular low pressure ductwork shall be constructed of galvanized sheet steel or iron in accordance with SMACNA standards and the following table: Width of Pant Sheet Thickness 0" - 26" 24 ga. 27' - 40" 22 ga. 41" - 90' 20 ga. (c -2) Ducts shall be adequately braced in accordance with the Fallauing: Width of Panel Size of Angle - Inches CO - 18' Standing Sears 1q " -36" 1 ° x1 "xl /8" 37" - 54" 1 - 1/4" x 1 - 1/4' x 1 /8" 55" and over 1 -1/2' x I -1/2" x 5/6' (c -3) All ,round law pressure ductwork shall be coestructed of galvanized sheet steel in murdered with the SMACNA standards and the table below. Low pressure round ductwork may be shop fabricated, following SMACNA standard and good industry practice. Diameter Spiral Sean Duct Lang Sean Duct Fittings 0 - 12' 28 gar 26 ga. 26 ga. 13' - 18' 26 ga. 24 ga. 24 ga. 19" - 28' 24 ga. 22 ga. 22 gar_ 2,4e - 36" 22 ga. 20 ea. 20 ga. 37' - 52' 20 go. l8 ga. iB ga. (b) (t) (d) (b) (c -1) Return air grilles shall be as specified m the grille, register aid diffuser schedule en sheet ' M -2 ' (or approved eapal). (c -2) Return Air and exhaust registers shall be sane as return air grilles but shall include a loose key lock type apposed blade damper. (a -3) Supply registers shall be as specified en the grille, register and diffuser schedule at shaalt ' M -2 ' (or anpproYad equal). (c -4) Ceiling supply diffusers shall be as specified an the grille, register and diffuser schedule an sheet ' M -2 ' (or approved awl). The diffuser will also feature m apposed blade radial volume central dapper, straightening grid and separate extractor. Finish shall be white marvel. (c -5) Callas care ctione shall be provided between all Fan openings and the sheet metal work. Caseation material shall be weatherproof and fire resistant and shall weigh approximately i8 oz. per sal, yd., by Vertfdo, cr approved egpal. (c -4) All low pressure flexible air ducts shall have impervious inner core with wire reinforcement. The inner duct shall be covered with 1.5' fiberglass insulation with polyethylene vapor -proof jacket. Flexible air ducts shalt be UL 181 tilted, Class 1, and shall met all local codes. (c -4 -l) Adjustable stainless steel ar nylon straps shall be used to secure duct fittings and equipment. A second band shall be applied over the jacket to maintain the vapor barrier. (c -4 -2) Fitting to cermet the flex duct to the trunk duct shall be designed to twist into the trunk duct and shall have a butterfly -type volume damper. Fitting shall extend into the duct to provide same air scoop devise for airflow. (c -4 -5) Flexible air ducts shall be the product of on established manufacturer of such products and equivalent to Fleenaster 3M type. (d) Medium and High Pressure Ductwork (d -I) This Contractor shall pay special attention to the re of VAV systems (when anppliable), particularly the taps into the Landtcrd'5 supply duct and the duct between the taps an the VAV boxes. These items must be rnatufactwed and installed according to AS-RAE and SMACNA standards Far medium to high pressure duct. They must also be in strict accordance with the landlord's regpirernents. Taps, ducts, etc. shall be air tight at the maximum pressures and velocity, shall be designed to minimize friction and shall not vibrate, rattle, etc. (4 - 2) All rectangular medium and high pressure ductwork shall be constructed of galvanized sheet steel In a,eeerdarnce with SMACNA Standards (tables 1 -5 through 1 -13) and the Waxing table: Width of Panel Sheet Thickness 0' - 26' 24 g a. 27" - 40' 22 ga. 41" - 90" 20 ga. (4 -5) Ducts shall be adequately braced in accordance with the following: Width of Panel Sits of Angle 0" - 18' Standing Scorns 1q " -36' I'x1'xI/8" 37 - 54' 1 -1/4' x I -1/4' 1/8" 55' and over I -1/2" x 1 -1/2' x 3/16' MECHANICAL SPECIFICATIONS (d -4) All round medium and high pressure duct shall be constructed in accordance with SMACNA standards Far medium and high pressure duct. Medium aid high pressure round ductwork shall be manufactured product by a firm regularly engaged in such work, with a catalog listing construction, weight, specifications and pressure losses. Round duct shall be in accordance with Landlord's rewire/rents and the following table: Spiral Diameter Long Sean Duct Seam Duet Fittings 0' - 12" 28 ga. 26 ga. 26 ga. 13' - 18' 26 ga. 24 ga. 24 ga. 19' - 28 24 ga. 22 ga. 22 ga. 29' - 36' 22 ga. 20 ga. 20 ga. 37' - 52' 20 ga. 18 ga. 18 ga. (d -5) Medium and high pressure ductwork shall have all joints and laps sealed with mastic swat to 'Hardcast' DT -5300 to ensure a completely airtight duct system. (d -6) Medium pressure flexible air ducts shall have a, inner core composed of trilan'Inate of aluminum foil, fiberglass, and aluminized polyester, with 1 -I/2' fiberglass insulation with a seamless vapor -proof jacket of metalized mylar. Provide a reinforced hanger strip designed to support the duct. (d -6 -1) Flexible air ducts shall be UL 181 listed, Class I, shall comply with NFPA e0 A, shall meet all local codes. Pressure rating shall be for 2" negative to 10' positive at 4,000 FPM. (d -6 -2) Adjustable stainless steel or nylon straps shall be used to secure duct fittings and equipment. A second band shall be applied over the jacket to maintain the vapor barrier. (d -6 -5) Fitting to correct the flex duct to the trunk duct shall be designed to twist into the trunk duct and shall have a butterfly -type volume damper. Fitting shall extend into the duct to provide some air scoop device for the airflow. (d -6 -4) Flexible pre - insulated air ducts shall be the product of an established manufacturer of such products and equivalent to Type 3M as manufactured by Fleaamaster Co. Or approved equal. (e) All ductwork shell be air tight, smooth inside and true to the d'rrreresions shown on the plans, which are finish inside dimensions. All joints shall be constructed to be air tight and smooth and true to size, Following the above referenced manuals. Joint spacing shall also be per the SMACNA manual. Standard seams shall be used on all traverse joints wherever possible. Longitudinal seams Shall be lock seams. Duct panels over 20' shall be crossbroken cr otherwise stiffened. Duct tape shall not be used to seal joints, to make transitions err for dry reason except the outside of wrapped insulation. Doors, coils, dampers, registers, grilles, diffusers, turning vanes, air volume extractors and other accessories shall be installed as required by the SMACNA manual with sufficient reinforcement and support and shall be such as to keep friction at a minimum. The number of elbows and turns shell be kept at a minimum. (f -1) Curved elbows shall have a throat radius meat to the duct width. Provide splitter vanes in radius elbows where indicated cn the drawings. (f -2) rsgp re elbows shrill have double - thickness terming vanes. (f -3) Transitions in ductwork shall be made with a slope not exceeding I to 5, preferably 1 to 7. (f -4) Supply duct splits shall be provided with splitter dampers and adjustable 'akin; ceradrant. Splitter blade shall be 1.5 time the smaller split width. (f -5) Supply duct takeoffs shall include adjustable air - turning device ecial to Titus AG -225, cr integral at diffuser in hard ceiling installation (see the plans) (f -6) All ducts shall be ade supported from corstruction above by means of strap iron hangers spaced art not more than 6 foot intervals. Stiffeners shall be placed at not more than 6 foot intervals. (f -7) All joints between sheet metal sections may be made with prefabricated joining systems such as Ductmate Industries System. System shall consist cf side rails template with mastic sealer for the ands of a cleat to join the side rails, and the caner piieces. The aide angles and cleats shall be made with not lighter than 20 ga. Galvanized steel, corner pieces shall be fabricated of net lighter than 12 ga. Galvanized steel. Completed assembly shall result in a zero percent leakage of air. (f -8) Flexible connections shall consist of a thickness of fabric fastened to both the air handling equipment and the duct in on air tight mariner. Flexible cecmeeticras shall provide no less than 2' clearance between sheet metal. Flexible canecticns shall be UL approved, neoprene coated, 50 oz. Glass fiber fabric. Fabric shall be Ventglas made by Verltfabrics, Inc., or approved eyal. (g) Flexible duct shall be limited in length to that necessary to make corrnecticre between turks and terminal units. This shall normally not exceed 5 ft. (g -1) All flexible duct shall be fully stretched out to reduce resistance. (g -2) Caseation to fittings or terminals shall be made with stainless steel or nylon bands, designed for that service. The inner liner shall be clamped tight with the band, then the insulation and jacket pulled up tight against the duct or terminal. Install a second bald sound the outside of the jacket_ Installation shall be as recommended by the duct manufacturer. (g -3) Support the flexible duct by the hanger strip with support wires on 30' intervals to relieve strain on any fitting. Unnecessary bends, seas, twists, turns, etc., will not be allowed. (h) All ductwork (if any) exposed to the weather shill have all joints, laps, edges, etc., sealed and coated with lardeast DT - 5300 and applied with FTO adhesive or approved equals. Clean all dirt and dust from duct before applying sealer. Duct shall be dry when sealer is applied. Apply sealer per manufacturer's instructions. (I) At the conviction of the duct systems they shall be usually inspected to verify proper frnstallotice and that they have sustained no physical damage. Check the duct system to ensure that there are no leaks at joint, taps, del, doors, reinforcement locations, act. (j) See the Supplemental Mechanical Specificatiene For alternate relative to re-using existing ductwork. (f) G12. DUCT AND PIPE INSULATION Low pressure Ductwork Insulation: All low pressure supply and return air ductwork shall be insulated with fiberglass duct wrap, installed in a first class maser and according to the standards of the National Insulation Manufacturer's Association and NFPA 90 A. Note that duct dimension shown on the drawings are clear inside dimensions. (a -1) Supply Air Ducts shall be insulated with 1 1/2" fiberglass duct wrap with an installed R value of 6.0 or greater. (a -2) Return Air Ducts shall be insulated with 1-1/2' fiberglass duct wrap with an installed R value of 6.0 cr greater. (a -3) Duct wrap shall be Owens- Gaming Fiberglass All - Service faced duct wrap, Type 75, I -1/2" thick or approved ecaral by Certainteed or Manville, The fiberglass blanket shall be factory laminated to a reinforced foiVkraft (FRK) vapor barrier facing. (a -4) The ductwork shall be clam and dry and all joints tightly sealed prior to installing the duct wrap. The duct wrap shall be installed with the facing/vapor brier outside and utilizing overlapping 2' wide stapling/taping flaps. Seams shall be stapled every 6' and sealed with pressure sensitive FRK tape. Do no overly compress wrap an corners of rectangular duct. Where ducts are 24" wide or mere, duct wrap shall be additiornolly secured to the bottom of the duct with mechanical fastener 18' o.c. to prevent sagging. Seal all tears, punctures or penetrations with tape. (b) Medium Pressers Ductwork Insulation: Wrap all medium pressure air carnditicning supply ductwork with 2" fiberglass blanket insulation with vapor barrier. Installed insulation shall have en R value of 5.0- See paragraph a -3 and a -4 For additional rewire/rents. Outdoor Air Intake Ductwork Insulation: Outdoor air intake ductwork insulation shall be 1' thick, 6.01t/cu.Ft. Fiberglass insulation board with factory applied Foil Scrim. The board insulation shall be preformed, flat, rectangular, rigid material. Maximum K value shall be 0.22 at 75 F mean temperature. All insulation shall be applied with edges tightly butted and fastened with mechanical fasteners spewed en 12' to 18' centers or as rea,ired to hold insulation firmly against the duet surface. Insulation Ebel' be secured in place with washers firmly embedded in the insulation. (4) All domestic cold and hot water lines shall be covered with 1' thick Fiberglass sectional pipe covering, with factory- applied jacket, or 3/5' thick Armoflex. loot water supply and drain pipes under lavatories shall be srnilarly insulated. Valve bodies and fitting the above covered lines shall be covered with 1" thick molded glass fiber insulation wrapped firmly under compression 2 :1 with copper class wire. Finish with 8 oz. canvas jacket smoothly pasted on. Provide vapor barrier for lines. Repair damage to present insulation where new carnations have been made, in conformity with the above speelfteattons. All refrigerant piping shall be covered with 3/4 thick ArmaFlex Insulation piping shall be thoroughly cleaned and tested before insulating. Weatherproof all insulation exposed to the weather. All insulation shall be Owens - Coming, Certaintee, Manville cr GI3. PAINTING (0) (c) (e) (f) (e) (h) (0) Exiet'Ing rooftop ec}eipment shall be completely repainted. All dirt, rust and grease shall be removed prier to painting. Apply rustproof primer to finish paint. Finish paint shall match the existing in color. No painting is repaired for new rooftop eceilrrnelt, except for labeling as indicated in Paragraph 'c' below. All rooftop eceepment shall be neatly stenciled or lettered with the store name and space number in letters 2' high. G14. EQUIPMENT LOCKS (a) This Contractor shall furnish and install hasps for padlocks on all access panels of all rooftop equipment. (b) Padlocks will be furnished by Tenant at a later date. (b) (c) G15. COMPLETE OPERABLE SYSTEMS (a) This Contractor shall be responsible for providing Complete Operable Systems For I4VAC, plumbing, sprinklers, snake exhaust, etc. This shall include any work not shawl an the drawings or specified elsewhere work not shown on the drawings or specified elsewhere that may be required to make a system fully operable in a first class maser. (For example this might include, but not be limited to; providing power wiring for motorized dampers an a landlord installed VAV box, control wiring conectioe, repair of existing economizer damper linkages, sealing corrections, repair of existing economizer damper linkages, sealing existing ductwork or upgrading/repairing/replacing existing chilled water control valves, etc. Refer to other appropriate sections of the Mechanical Specifications). (b) Portia s of some systems (i.e. 1VAC, plumbing, sprinklers, etc.) May be existing or be provided by the landlord. This Contractor shall determine the extent of such partial systems and the conditia& of existing eiripnent when preparing his bid, and include all necessary work for a complete operable system. Thorough examinotice and testing of existing portiere of systems is required. (0) This Contractor shall coordinate all work with the Landlord and Tenant's Construction Representative. Advise Tenant of any necessary work not detailed or specified. G16.'� tFST FOR A CCEPTANCE (a) When the heating ventilating and air conditioning systems are completed, the Contractor shall run the apparatus when directed by Ter2nt's Corstructian Department for the purpose of testing the systems. (b) All equipment, fans and motors shall run at their repaired speeds, without slowing undue vibration, objectionable noise, or sporking. No bearing or journal or cry pert of the mater shall heat to a temperature of 50 F above the surrounding air. (c) The Contractor Shall adjust the delivery of air at all openings through the building according to the amounts shown on the plans, or as required (+ - 52). (4) All labor and materials and all instruments required for adjustment and testing shall be furnished by this Ca- tractor. (e) All egeipment shall fulfill the capacity requirements specified. (f) The drainage system shall be tasted in accordance with the rules and regulati i5 of the local Board of Health. (g) When the plumbing system is completed, a test shall be trade in the presence and to the satisfaction of Tenant's Construction Department. This test shall include the operation of the entire system. All valves shall be tested open and closed end shall be free From leakage at the packing. All fixtures shall be operated and tested for supply and waste. (h) Any defects mode manifest by these tests shall be rectified by the Contractor. W5tfle[c[ Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all govemmerrt regulations. One (1) copy of this landlord stamped set of drawings is requir- • tope kept on the job site at all limes. F 1 /3/08 Si ned Date 417. AIR BALANCING REPORT (a) This Contractor shall obtain the services of an independent test and balance agency with technicians certified in air balance work by AAABC, AEE, or SMACNA to test the entire I4VAC system. This agency shall submit, directly to Tenant's Ccnetruetien Deportment, a certified report verifying that the system operation 1s in accordance with the plans and specifications, including the proper operatics" of Various dampers on the 1 ecenanizer 1 , day, night, heating, and coifing cycles. This report shall also indicate the cb,antity of cuteide air entering the system with the damper an the minimum and maximum positions, and the aeeantity of air delivered to the space at each supply diffuser cr register. G18. OPERATING INSTRUCTIONS (a) Upon canpletion of the HVAC system, this Contractor shall provide simplified and clear operating irstructiens of the entire I4VAC system for the use of the afore manager. These instructions shell include, but not be limited to, simple instruction of how to set the thermostat on 'auto', 'fan', 'heat', 'cool', etc., and operation of the 'NiteStat'. Consideration should be made to mall energy management systems. Note: Instructians are not rewired when the system used the Haneywetl 17300 thermostat. The thermnc tat program is to locked. All other equipment instructions are to be furnished. (b) These instructions shall be an a neat, typewritten card, mounted in acetate, and mounted above the light switches in the stockroon. A copy of these instructions shall be mailed to American Eagle Outfitters, Construction Department, 150 Thom Hill Drive, P.O. Box 788, Warrendale, PA 150g5. (e) These simplified instructions are not the sane ac the manufacturer's catalog cuts called Far elsewhere in this specification. G1q. CLEANING AND FINISHING (a) After all tests have been made and the systems pronounced tight and satisfactory, the Contractor shall go over all his work and clean the ducts inside and out, equipment, fixtures, piping,., and leave them in clean and complete working order at the final completion of the store. (b) After dust producing construction phases are complete, and immediately prior to turning the project over to the Tenant, this Contractor shall furnish and install a complete set of new filters in all HVAC eer i:merit. G20. WIRING FOR MOTORS __.._. (a) All motors shall be furnished and installed by this Contractor. (b) This Contractor shall furnish and install all starters, push button stations, relays aid control wiring pertinent to the operation of the I4VAC equipment. The Electrical Contractor shalt furnish end install all power wiring and non- integral disternect switches. (c) This Contractor shall furnish the Electrical Contractor with necessary diagrams for his use, at the time of ordering egpiprnent. (d) All motors 1/3 HP and small shall be single phase, 1/2 HP and larger shall be three phase except as otherwise specified. Thermal overlaid protection for all motors shall be provided. Magnetic starters shall be provided for all three phase motors. Thermal overload relays shall be sized for 125! of full load motor current. Switch and fuse wilts will net be acceptable. The installation of all motors, starters, and other electrical work shall ccnforrn with the National Electrical Code. G21. HYDRONIC BALANCING REPORT (a) This Contractor shall obtain the eervices of en independent test and balance agency with technicians certified in hydrenic beano. work by Ni+AB or AAt9C to test the entire I4VAC hydranic system. This agency shall submit, directly to Tenant's Construction Deportment, a certified report verifying that the system operation is in accordance with the plane and epecifications. A. The following procedures must be followed: (a -1) Examine the contract documents to became familiar with the project requirements and conditions for proper TAB of hydronic Rystern(s)• (0-2) Examine the hvac hydrenic system(s) and eqpipment installation to verify that indicated balancing devices, such as test ports, gage cocks, thermometer wells, flow controls devices, balancing valves, fittings, and manual valves are properly installed and that their locations are accessible and appropriate for effective balancing and operation. (a -3) Ex rnine strainers for clean screens and proper perforations. (a -4) Examine two ar three way Valves for proper installation for their intended function of diverting or mixing fluid flows. (a -5) Exanine heat transfer coils For correct piping canrnecttons and for clean and straight fens. (a -6) Examine swipment for installation and for properly operating safety interlocks and metro's. (a -7) Examine automatic temperature system components to verify the following: 1. Dampers, valves, and other controlled devices are operated by the intended controller. 2. Dampers and valves acre in the position indicated by the controller. 3. Automatic modulating valves are properly connected. 4. Sensors a'e located to sense only the intended motions. 5. Sequence of operation for central modes is according to contract documents. 6. Controller set points ore set at indicated values. 7. Interlocked systems are operating. B. Change -over from heating to cooling mode occurs according to design. G22. (b) Check system resistance. With all valves open, read pressure differential across the entire coil aseernbly. Adjust all specified flows ore specified. (G) (d) Perform the fallowing balancing operations in addition to the above if hydranic pumps are included in the design: 1. Verify impeller size by operating the pump with the discharge valve closed. Read pressure differential across the pump. Convert pressure to head and correct for differences in gage heights. Note the paint on manufacturer's pump curve at zero flow end verify that the pump has the intended impeller size. 2. Cheek system resistance. With all YalVee open, read pressure differential across the pump and mark pump manufacturer's head - capacity curve. Adjust pump discharge valve until indicated water flow in achieved. 3. Verify pump motor brake horsepower. Calculate the intended brake horsepower for the system based an pump manufacturer's performance data. Compare calculated broke horsepower with nameplate data an the pump motor. Report conditions where actual amperage exceeds mater nameplate amperage. Report all hydrenic balancing warders to American Eagle Outfitters including: 1. All hydronie water flow rates in gallons per minute. 2. All hydrcnic water pressure drops in psi and heed. 3. All flows through calibrated flow valves. 4. All pump data (iF applicable) including flows and brake horsepowers. 5. Water temperatures altering and leaving coils and mixing valves. GUARANTEE (e) (a) The Contractor shell give to the Owner a written qua-antes that he will make good, at his own expense, any defects in material or wa which may develop in one year from the final acceptance of the worts. (b) All compressors for HVAC units shall have a Five year no- prorated factory guarantee. A written copy of the guarantee shall be furnished to Tenant's Construction Deportment at projection canpleti'I. Le o RECEIVED CITY OF TUKWILA FEB 0 4 200 PERMIT CENTER r f s keLi NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS CN THIS SHEET NOT LISTED ALPHAIHA ETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO TI.115 PROJECT. • • . 9 SUPPLEMENTAL MECHANICAL TRADES SPECIFICATION NOTE The Mechanical Trades Spealfication Is divided Ida two prteg I. SUPPI-EMENTAL MEC.NANICAL TRADES SPECIFICATION Minh; the wax of work and the special recoiremerts era materials for this project. GelERAL MECNANICAL TRADES SPECIFICATION defining standard requirements and materials. If the General Mechanical Trades Specification is not attached, =tact Tenant Immediately. In the event that conflict exists between the General Mechanical Trades Specification and the Supplemental Mechanical Triodes Specification, the Supplemental shall take precedences. SI. DRAWINGS (a) The Mechanical Drawings, the General Mechanist Trades Specification, the Architectural and Electrical pions and specifications form a port of this specification. S2. SCOPE OF 1.4ORK (a) The seeps of the wk shall include, but not be limited te, the follow ing areas and related miscellanecus work. (a-I) (a-2) (a-3) (a-4) (a-5) (a-6) (a-7) !rat:India, of a Fen Powered VAY Sax and Control Installation of on air distribution spawn. Installation of a connplete 14VAC control system. Installaticri of a sprinkler system. Installation of a arnplete plumbing system. Installation of a toilet exhaust system. IF required by Landlord cr local building codes, installation of fire and Emoka detection system. _ i`oFF,,i1° (a) The Landlocil Net.) complete. attnirkier eysten prier to z-ta (b) Ariy aita-deignit • roe 4t95 tr.S; Terra sprnkter t-cntrectrsr Tersarg, amt. Alterdienti, shell bse iii ti tkr 1-r-d For tippneeal priar reei hcaelifieatisths to tile 0Itstari, S4. SFRiNKLER SYSTEM Flodify) (a) This C.entreett..-r• tI tiss cf. arinitter ca-Ar rg.-tieT. far thin to inay.1;fy cpr- 44W- ayes, ac- rtin..inad (b) Osri4der inetoliceion must ti.t. to 4i th r irr ..yrto thxe L.gi-tdiord's otd cretit- t orei reyiret.1 0g., thio greenimtion Par approval. r,a) PION *Nal be Etch thnsoadod. 175 pa Ziet,s4utu 10 hith fittiruo *0-4. cti) Tho Contr,ne tha Lihianitritcs-'e awa-rol rigt- ganst-tkr 1.41 Lr r•r ,4 sp..-4ba 1-: fully =.prrnklari*t1, but tile wiecct 4t 11-4 Indicate 4 trl'Ild kreacii, whkih may by. l-ktuovo it is th.t. rrt thg N; tktieVrrit 4 . rMeW kIVCItierIL tik V4 470 rev layout, which iteuld ut1livt. eitieLN latitm- 1,vecible. The netu laput rra,at moot *It apoliaetzle cogiee and Londieed Mtpir*rriAnti, i th4 drawnot- must Us&, ineilae,c, (thew or* Meted ' Hots that t hey sale* f•e',64 &1i:r utock erea opt*ilageg) ateilinq 15 beirq installed at IV-W. Sprirkier. ince ongl ;seed* mixt ba mLt e4-kitictegi This tr hull tetsmit uta .....osess at the spn'aikin. a,* , r-tuoin,,7 5 ,5 thit Landlana'a Piro i'er- approval. 1-1* sivit then eulernit two copies at' the dr, bem-0-1.4 tiMo.euriear's approval to V L1IQ4 ..nd two tti Tenret. Submit other aepleis ity ro.°A. with tine. 1,..gridltral. M. SPRINKLER SYSTEM (New) (a) (b) (G) (b) pipn4 with !: cA-c--37:44k4. l,figtaulla type This Contractor ehall obtain the services of a sprinkler contractor far this wee to Install the sprinkler system as required by drawings. Sprinkler intstalledon must conform to al the requirements and regulations of Landlord's Underwriters, and all applicable code, and all sprinkler contractors are required to subunit working ciNculngs to this organkaticn for approval. This Contractor shall submit six copies of the sprinkler shop drawings to the Landlord's Fire Underwriter for approml. I-le shall then submit two copies of the drawings bearing the Lndarwriter's approval to the L.cridlcrd =1 two copies to Tenant Submit other copies as required. Verify reqpirernents with the Landlord. HFi histallaticn is approved by Landlord and Tenant, the sprinkler (=tracto• will activate' the system. The piping sting shall be based cri 'ordinary hoard', hydraulically calculated. Submit calculation to Taront. Piping shall be Schedule 40, ASTTI A-120, black steel piping with threaded end, rm psi class, UL Approved, cast Iran Fittings. Piping system shall satisfy Landlerd's pressure test. Upon completion of the sprinkler syetern, ths sprinkler contractor ehall hydrostatically test all piping at 200 psi for two hours. (h) The Cantracter shall mare the Landlord's Underwriter's approval Fier to =median to Landlord's system_ 56. INSULATION (a) All ductwork shall be insulated in accordance with %clan G13. of the General Mechcnical Trod.. Specification. Dinensicre on drawings cre clear inside dimensions. Outside duct dirnensierts shall be adjusted caccrdingly. All new end existing chilled/hot water piping shall be insulated with 1 thick glass fiber pipe Insulation with Matey applied vapor barrier and white kraft paper covering end Flaps. Flops evil be neatly pasted In place. All joint's shall be sealed with a year brier cement. Fittings and valves shall be covered with pre-famed cr mitered eagments of the pipe insulatien end sealed with two wets of vial= barrier cement reinfcroed with glee cloth tope between wets. Insulation shall be me by Owens Ccrnina Fiberglas Carp. or approved equal_ (IF applicable) (a) Rapcir insulation on existing chilled/hot piping. (if applicable) (d) Repair all Insulation an existing ductwork. (if applicable) Cs) insulate all rerrigertrit lines. (if applicable) 57. MUST FANS (a) This Contractor shall provide and install ceiling exhaust fan for the Toilet Ream where shatrt on draubgs. Fen shall exhaest CFM at .25' S.P., and be complete with backdraFt ckmper. Fan to be ACME VQ-100 or approved equal. 120-1-60 volt. The trtieting il tokaust fon in the toilet swans el=11 b red ft.ief, =tory cml Vaal. Nei.; T (4-) This Ca 'Licata 2111 (b) IthamirAs ptoce ft V tirst-eltmis aeration. Baclairaft *•ore musk tir agnpletely owtible, SS. TEST 4 BALANCE REPORT (a) The Jr A Balance Report specified In Section G17. of the General Meclronical Specification ehall be submitted to the Landlord as well as to Tenant. PLAT () Refurbish air eapitze exicties;i roof n--tetnteii viertilaters r et-twor reli oir A 11 las alwriintra corterwctim hsth vsntilato,- ran tr approved to be 11 Ss. Ft. (lb) Voititaters el-41 Airotte by F Ventilator Ire. oi approved V‘1. 51= WAUST PAN (e) Th C..ritractor shall fumit.h and iretel acel *hall , tth whom looted vt " C■EL. copal. Fsn met ?Cr Q tho Latlionsi's roofing this s*-krocter's =pence, e.) (:) ( (a) haotinsii etweity L The cabinet °0,1.2311 **limbed steel The ' i.;.+1Th bckeil 111 4) , pale likitirne iubrigerted • I a smolt. svccuatien fon at and avirit of ate Firevidv rtief *Leib that contractor Po mount S P4C7 fr'99•M4 (i) Prattle rst-feb-iected etrbs, flasitiha and - flaehings far ali Tt, reef opianirte to t LE. L by portacm oil reef . --i eu 'a. * . • . ...rfacttregi Pate CAtclaa, !no, (b) All roof og,0--k shall Exe by the i_on4crol's r.ontrrxter at thig Castmcto• .Aptram. Al; wok evil 6s ettrotly er=rlding La V2. - ..i1STiN* Ca4DITIONS This project le installed in a previctely eaciOad wee. Demolition ter this apace has bpi cowed, in oneral, ungisr wercte zpecifiectlen. go) ifil; tIA.A-44 that! hc.lcrs • or othir w.-rk rro to pivi: . All systaro cir-td Cirt zhoil . r. f Ctrtd-n ogvipment (i-IVAC snit, etc) s°:riall ted reueik indi-mtagl plum. Th1s Centrorta- sveriPy tta cot t.4 eftiathl ament ond ides in Ns bass biel o pries for rapt's:61g 4.00tipment not deemed rsiott,dee by - remit This Contrmtgr zH iriforTi AEO of any swiarrt41-,t that is in gyesticels aer4itiets, ALTERNATE 14o. i (c) Th Ceistrm may ne-use weres tr oil of t.hts dyttva7r4t if it rat to exacol 1200 MI. r4po metes sr derriaatie:i ifitulatto n , Cap io ganalitian, the prom- eise fen the n system hes specified domfmrs, craters, tornim yam, " .."10W ir ar. with thg (b) This Cantra.,.t-a- ol to dieke,,* ti thol 6114141:1 thaw ■46MItark. This engineer shah submit te Torw-ift., a letar clertifyiN that Liu titi-see-rt wdl Funetim tee specified. (d) Rgelesid dt4ttut- mist handle thei o' 4roAltivi e. o saiwity oil immaci operiirw with chmit , g,:rek46, d lk drtictitt. Check ter air :actdc end sod. Proy144 Terwit with a drouAra showing rativ si*e M tiiffacer loodiace, Thir. Cositrg*t o. shall noIcato In his bid thsi am,-,telt to be 4:ducted from the base bid if We alternate is ***opted. f'45tei 6.Agoo the 6ttlrriata is proposed to aid er-c4pted by Toot, no seating il shall be excepted. $1.4. FIRE AND smcie DETECTION SYSTEM If required by the Landlord or local building codes, this Contractor shall cooperate with the B.C. To furnish and install a fire and smoke detection system including but not limited to, smoke detectors, wrecks exhaust fans, visual and audible alarms, tamper erid flow switches, etc. All equipment must be fully operable and meet Landlord and local building code recylremente. Contact the Tenant representative with crry die:restrain or miwnderstanclings. SI'S - el-KT - RIC WALL rdiNTM 1.1141T t-lEATM 'Ns Contractor airwil firnich cat -hatoli a wail rnato4 eicatrk it hex:4w •e:J.5 a 15 gawp tI uolI revant1N face* of the eceirg taerceitri. The alit heater shell be a hl ne ecpxity of The ea 44J0 Forinsel steel, Th - Prat ot adjustable shall be peat dr= thr•Nrith dAtkr aliminata het spots. Ali hTALf 101t-Cgp CrttrgW g41-111 proeideel with the unit isr5iatet-. Freeriale a disecnt at the urn l'acter. 1.1 shall wimi far Voit, —Ftaitu, CV harts opereeia All ,. *hail be por unit menstotturen retvirenocts. Tito (nit hcat.on ehall be made t1 oa tracafootw4 by e; apprved fe:TRIC TOLE• ReZ11 ALL idE.ATM This Centro:CT shall furnish end ii•ztoll a recessed aleatele uo luater with at 20 oo:as itshed oltrn?sim tais complete with 4 wolvzot corh , p4.0..satkin, en?, fintmi theatint..1 hoot ing eke-nett. AU atintrols 0411 be inteignal to the wall heater. WI heater shall be wired fer et1 •airto. open:Man. Al! instAlation shalt be pr snit rrialufacturat- reavirerrarite. The wall Polar shall kio rric.4,11 mcfAsik4tvmd ty amcA r cepitmwe ) SAZ PIFfgfi (0.9 44.0 piping tholl be A.S. k Of.eel Oping with I% pel maltegible • II (b) *re pin tP-. ° • P , ,„/ carter with diNfAl2" •:megd Neport also at tote 4nel elbows. MECHANICAL SPECIFICATIONS SlE, 0-1114,40 KAM PPM a riT (a) Ellir-toice° raltia watze,-, *he crawl Pips Matoricii Sciiodula 40; sotenless per A3T11 AI rod A ,T 0, ar ASIM M1 cioat6 A of. () (a (d) chilld Ka-ter Valwt, (4-1) Viall be all W"i7V4 t1i Vt9;Vg±7 l'Or 1 kw 2' arei gerialign Cobra irsiteriA-im ..wptra4 OSi4i. Val VIZ rood f glp :E4). syt,tt:51 ,p,tmon prasstre. s. I:44*ES (a) (4; (a) (e) Fittims. Presate-e. RatintA Serviat Pipe tictirM Fittingui Pc RAN 15 F:114 4,7grwel:: a .5-1W;yieb:Piph3 e...sger.rtt *4 head amsry .tari (a) C3o CPi bar 'retailed on the r/p ;1de L* the -1.1relort brattext JantA, Cosa "4"-•'•L fi,a-rGe ftg- strf • ttrnlah 411.19 a:oak, (b) tlogez shall b aloe 4",k :WV114 0•414 90. n4mer1alrrat9 (a) 'V4 1lF th oiI meratry flited, rad rearelliN, ocitn-ri typo. Coltrrei shall be mo.r berFer dont-gee *Wel aosp with Oat free. *hell L arniched tot. OZ. CIRC./LATIN* NM' Pr*.no, rtrni*Ic bui1t+ itq° h*h limit peetsg.tie, All terminals 0 stream. Noctere *ageo 'ubssu c Co es shall itan24.1s shall hs c--0 6A1 typg id F.haii las not I 4g5A. • „ r zuitFk;'* isanith to properly carms weer to.npr when 0 w pp. ti r471EIS ahert k9 red IC40 ti tlf 2M? P, with hat more than 2 &awes division*. Was 4.,ati be 4 01 oh puelticsi thek tl'asy do not rcist,-.1at the Mow o wa ter. in ttv. p. Thor./n4..natirs be tin If -eramiele. Medal mad* llaiMMENTS per Fty,sidds, aMuii re-azure seal temperature tt plugs. Plikj bo4t orget ;Teas, thread" ° ahall titAl Ner6e1, ash t.I r asS IWO pel. (b) Finnish a separate lt wile 0 7CV F thermometer 0-225 F iksit-mseretro-, adoptve. and cort• 9Z. TI-PME--klAY MIVIck.; VALVP (a) li-osido wiwe shawl a tirec-teey so-4er valve and gsapropriette thru g iil Lys oast brew salvo* 2-1, end loser shall ki a - gast hratati end t rat4 flamed i121! iv140 t bard I2'5 (b) Valve *oil be mstrted ii re, oricht ition fan h that the deti.e.1 k revismid. Valw ri o 1,71* o ths7it. ths stk..* seuts , i:rsaiiet, the flow, (a) Valve oll a 111RW.rr i.";entrols, SV5-4.5.V a: OVA.-Ek140( vette-tr., arpirrT,4-1ato. er ad eval. Famish a-le. 'enstall :a-9 p1 ii°Tyro-lat..1, Vet oporat/rig ; Iptrr,,:z. .:rri:171 ,tr 7w 1 '1* 6hli .irina motor. . prvserre arf likelooled 1*-stinic sleeve bear zit/ up-24er seal. (b) rautatitm ptrisp tv Balt with , relator Fr epee-ration. (a) Sst ptelip far Q ._' pre-tare. S2.4. FI.C1?-1 CCATCRI., YtLVt (a) Fl ets un-/toe :keel ba, ag1P-cantizi, inNOortiN oivo with hi pird. who, erdi Val ,e-01% rkeit i ca-ewistatt. -it Psi) preautnas, flt-Au notoe ntiketit..-q w 4-nai (b) Velv( 0:41 bo brTIth kr M59 otoia contemn litex•rogl polx. Ell 4 tlTt4 ar aidw t-13 cre,:ialnIng pips. Valves shall bo rJ atar kre oll Gawiti, or wrovii4 al by Cs-isttiald 1-v4w-clean Volvos ',2-11Y aM laic Herron eigtexilie and with brass or stainless *tee! Int,eendi We. Figniale with locoAAteties tops $25. ELECTF-tiC a:CT 1-1E:ATMR (Creli 0:741..) (a) 51'...gtecric duct heat-sr &,ati rx aii 46/-isems, tr-oteitat In a Hai* ktij etutteh, .,,. and .0*re:4e:tor, the air draratkr —KM, —05 IC typs 47.LA Fraio by Maa ezrcel oval 52°L. ELECTRA Duct' REA Eltratela. rat Nvov L 47' alia-c opsr, cal 4,04 with hwtor•Atie pi.-0 elite-me.1 autcet, *Aid irk hete. 'dmitiere ki reat.ti pMa ma in die.e.grneol. stu discosimt *witch. . VZ.,e4 104 f(if Prtkqg , asitra renviita, e*nwiters, ;Frav•••• Frotegtieri, rake/a acid rvir4d6d1 it tikgil rivitritetl 1.1 c latdele,1 *antral we! at the &fl(e). A ar cio apareod switah aM1 intreia*ist.6 with U-r.to shall . O4 arr.-reed thr?i" 5tf4 City tral nzli droviNe (rnexinItim et 7 P. Hbs Coo shall air:, bo e 441;1 r•-1 Z,‘Th7t hvie t Eleerei4 41,4t• I'VLVer4 ' NI —.volt, 5 phase far open-otlen„ Mni:'etre t . — . 527. AUTOMATIC CONTROLS FOR VAV sysTEN (a) This Contractor shall Install a Landlord provided system of Fully cute:matte centrals. The ccntracte• Obit do all the memory control wiring and provide end install all necessary central devices. lellring shall conform to NEC and the Electrical Specification. Coo-dinate all control wiring with the Landlords building mancegernent stystern. S25. FAN POWERED VARIABLE AIR YCLUME BOXES (a) This space is to be serviced by fan powered Valable Air Volume terminal This Contractor shall furnish and install fan powered VAV terminal urtits of the ebee shown on the drawings. Cartracter shall verify the rnawfachre- and model nurnbers of this erciJipment when preparing his bid. IF this Contractor feels that the equipment carrot provide odeoporte, even cooling notify Tenant immediately. (b) The fon powered VAV terminal box= shall be of the 5a1115 indicated on the drawings, end shall be equipped with electric reheat coils, sires as Indicated. Nectars shall be two stage, far 4180 volt, 3 phase operation. (c) This contractor shall comsat all controls in occerdence with the rnarsuFacturer's and Landlord requirements. D Si ned Wstfletrt RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER Working Drawing Review ic Approved Approved as Noted 0 Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant Is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- to be kept on the job site at all times. 1/3/08 `'°17'E• Date of • blitro ■•. I*2711 DETAILS, NOTES, AND/OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPI-IABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 4 thawing No. MS.0.2 E 10 ct 6' 0 ._ INKOMMILO D -2 — I _ ri i nEn I I I 1 i( I 1 _ I . F . i I. Li 1 1 - 1 . - - _. - r I 1 _ . rrr -- I r•r - r - rl7_ - r r I I i I F TT FITTING ROOMS CLG ®11' -O" FIRE CORRIDOR 14x12 TRANSFER DUCT 36x16 COVER W/1 "xI" STEEL MESH SECURITY SCREEN FPVAV -I �_1 MWM 36x16 S 1 - ES ----- ARE - A THERMOSTAT MOUNTED 5' -0" A.F.F. COORDINATE WITH E.C. SEE NOTES AND SPECS. EXTEND TO FPVAV -I 14x14 { I 1 NO CLG HANDICAPPED TOILET ROOM a® ®o® et STOCK Room m CEILING EXHAUST FAN EF -I SEE NOTES, CHART AND SPECS. EXTEND 10" X 3 I /4' TO 6" DIA. CONNECT TO LANDLORD'S EXHAUST CONNECTION. CEILING = 8' -O" SEE ENLARGED TOILET ROOM PLUMBING PLAN AND PIPING DIAGRAMS ON DRAWING M -2. FIELD VERIFY EXACT LOCATION AND CONDITIONS. SEE NOTES AND SPECS. Wsifiek[ Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir =. to be kepi on the Job site at all times. Q r 1 /3/a 8 Si • ned Date a 23' -2" THIS CONTRACTOR SHALL PROVIDE AND TI-415 CONTRACTOR SHALL INSTALL A COMPLETE VAV SYSTEM. SEE M -2 C1 -IART, NOTES AND SPECS. VERIFY LOCATION OF UNIT WITH LANDLORD REP PRIOR TO UNIT INSTALLATION. PROVIDE SMOKE DETECTORS IN SUPPLY DISCHARGE TO DE- ENERGIZE HVAC UNIT UPON DETECTION OF SMOKE. THIS CONTRACTOR SHALL COORDINATE WITH THE LANDLORD AND WITH THE G.G. FOR THE PROVISION OF OPENINGS IN THE DEMISING WALLS FOR RETURN AIR. VERIFY NUMBER, SIZE, AND LOCATION REQUIRED. ALL OPENINGS TO HAVE I "xI" WM MESH SECURITY SCREENS. NOTE: MECHANICAL CONTRACTOR SHALL FURNISH ALL REQUIRED MOTORS AND STARTERS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION AND WIRING. 301�01n R2l - 4 7611 MECHANICAL PLAN SCALE: 1/4" = 1' - 0 MECHANICAL INSTALLATION NOTES: ® LANDLORD'S SANITARY 4" CAPPED WYE. VERIFY LOCATION AND CONNECTION POINT WITH LANDLORD_ ® ROD OUT ENTIRE PLUMBING SYSTEM BACK TO LANDLORD'S MAIN. ® COAT ALL UNDERGROUND CAST IRON SANITARY PIPING WITH ASPHALTUM. 4 M.C. SHALL COORDINATE WITH G.C. TO PROVIDE NECESSARY CUTTING AND PATCHING FOR SANITARY LINES, DRAINS, CLEANOUTS, ETC_ SEAL WATER - TIGHT. ® ALL BRANCH TAKE -OFFS TO HAVE LOW LOSS 'SHOE TAP' FITTING. ® ALL BRANCH TAKE -OFFS TO NAVE A MANUAL DAMPER. Q7 THIS CONTRACTOR I5 TO VERIFY THE EXACT LOCATION FOR THE VAV UNITS, AND PROVIDE ALL NECESSARY AUXILIARY STEEL REQUIRED FOR UNIT SUPPORT TO MEET LANDLORD'S REQUIREMENTS. ® THE MECHANICAL CONTRACTOR SHALL CAULK AROUND ALL SINKS AS PER THE HEALTH DEPARTMENT CODES. USE SILICONE SEALANT ONLY. ® PROVIDE FIRE DAMPERS WHERE DUCTS PENETRATE RATED CEILINGS OR WALLS. 10 SPRINKLER HEADS SHALL BE PLACED INSIDE AND ABOVE FIRE CORRIDOR, WHERE APPLI ES. 0 EXTEND 1641 DUCT TO EXISTING LANDLORD PROVIDED SUPPLY AIR TAP. VERIFY WITH LANDLORD EXACT LOCATION. 30'-0" (350 VOLUME DAMPER ( MANUAL) SUPPLY AIR DIFFUSER (BLACK INDICATES BLANK -OFF) 16,x10 +=DS • IN RETURN / REGISTER OR GRILLE INSIDE DUCT DIMENSION (in inches, first dim. is as viewed) SUPPLY DUCT TURNED UP SUPPLY DUCT TURNED DOWN RETURN /EXHAUST DUCT TURNED UP RETURN /EXHAUST DUCT TURNED DOWN ELBOW WITH TURNING VANES PREFINISHED WHITE CONCEALED SPRINKLER HEAD PREFINISHED WHITE RECESSED SPRINKLER HEAD BRASS PENDANT SPRINKLER HEAD 22-10" ECHANICAL LEGEND U 1 HANDICAPPED FLEXIBLE DUCT (NOT TO EXCEED 5' -0") SPIN -IN TAP WITH VOLUME DAMPER DENOTES CONNECT TO EXISTING FLOOR DRAIN W C WATER CLOSET "' t CI F.D. LAV NEW DUCTWORK EXISTING DUCTWORK TO REMAIN a SMOKE DETECTOR SUPPLY AIR DIFFUSER (LINEAR) LAVATORY S AiAto r , ,_ m m RECEIVED CITY OF TUKWILA FEB 04 ?'c'3 PERMIT CENTER 7751 . U ° 4- 3 o EXI -TAU ST FAN SCHEDULE MARK DESCRIPTION CAPACITY LOCATION EF -1 ACME CEILING EXHAUST FAN VQ100 120 -1 -60 '90 CFM 0 0.25" SP TOILET ROOM ACCESSORY COLOR LOCATION NOTES SD -1 SUPPLY DIFFUSER 18x18/124) 24x24 FIATER NEATER SCI- 4EDULE MARK DESCRIPTION CAPACITY LOCATION EWH - I ELECTRIC WATER HEATER 6 GAL, 1500 W 120 -1 -60 ABOVE TOILET ROOM GRILLE / REGISTER $ DIFFUSER SCI -IFDUL MARK TYPE NECK SIZE FACE SIZE CFM PATTERN MANUFACURER MODEL ACCESSORY COLOR LOCATION NOTES SD -1 SUPPLY DIFFUSER 18x18/124) 24x24 355 A4 TITUS TDC TRM #26 SALES W/ O.B.D. SD -2 SLOT DIFFUSER 4' LI±NGTI -I (2) 3/4" SLOTS 200 - -- TITUS ML -36 - -- #26 FITTING SD -3 SUPPLY DIFFUSER 1)x13/1240 24x24 300 A4 TITUS TDC - --- #26 STOCK W/ O.S.D. 5D -4 SUPPLY DIFFUSER cixq /64) 24x24 100 A4 TITUS TDC - -- #26 OFFICE W/ O.8 -D. RG -1 RETURN GRILLE - -- 24x12 - -- - -- TITUS 50F TRM #26 SALES MECHANICAL NOTES . THIS STORE I5 BEING CONSTRUCTED IN A NEW BUILDING BEING CONSTRUCTED BY THE LANDLORD. THIS CONTRACTOR SHALL INSPECT THE SITE AND MEET WITH THE LANDLORD'S REPRESENTATIVE TO DETERMINE THE EXACT FIELD CONDITIONS, SCOPE, AND PROJECT REQUIREMENTS. 2 THIS STORE IS BEING CONSTRUCTED IN A i iA ,CE WITHIN AN EXt:.�T"1N.G BUILDING. THIS CONTR.,. L (I ' SITE AND MET WITH THE LANDLORD'S REPRE,5EN :: D' lit I EXACT F EL; C� DI ° iIC ?1d�, SCOPE, AND PROJECT 3. THIS STORE IS BEING CONSTRUCTED IN A PREVIOUSLY OCCUPIED SPACE. ALL CONTRACTORS SHALL VERIFY AT t` - - .HE DIMENSIONS AND DETAILS SHOWN ON THE '. `Gb E .. MFAi 1ELF WITH THE EXISTING CONDITIONS.`. ,_�: I '� �: ERIFY THE ACCL "AC OF ALL DEi'A1LS AND ib E"N51CNS SHOWN ON THE DRAWINGS AS 'EISVINO;.'. NOTIFY AMERICAN EAGLE OUTFITTERS' CONSTRUCTION DE „°.AR T MEN WI I4 ANY CONFLICTS. EACI-4 CONTRACTO SHALL BE RESPONSIBLE FOR ANY INCIDENTAL DEMOLITION OR NEW WORK REQUIRED BY THr.: EXISTING CONDITIONS. SEE SPECS. 4. THIS CONTRACTOR SHALL COORDINATE WITH THE G.C. AND /OR LANDLORD FOR THE MOVEMENT OF MATERIALS, TRASH REMOVAL, ROOF WORK, TEMPORARY DISCONNECTION OF THE SPRINKLER SYSTEM. THE LANDLORD SHALL FURNISH AND INSTALL A SPRINKLER MAIN. GRID PIPING, DROPS, AND LEADS SHALL HE INSTALLED BY TI415 CONTRACTOR. THE DRAWINGS SHOW AN 'ORDINARY HAZARD LAYOUT'. THIS CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR A HYDRAULICALLY CALCULATED SYSTEM, IN ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS, AND ALL APPLICABLE CODES. SUBMIT SIX COPIES OF THE SHOP DRAWINGS TO THE LANDLORD'S INSURANCE UNDERWRITER FOR APPROVAL. SUBMIT TWO COPIES BEARING THE APPROVAL STAMP TO THE LANDLORD AND TWO COPIES TO AMERICAN EAGLE OUTFITTERS. THE EXISTING SPACE IS BELIEVED TO SE FULLY SP RINKLEP,IT)), BUT THE HEAD LAYOUT IS UNKNOWN. THIS DRAWING SHOWS AN ORDINARY HAZARD LAYOUT, HOWEVER, THIS SPRINKLE co °' INSPECT THE Sr ACE, iD t'ERMINE THE EXIST.L':.... !" -A . «•tS AN �E'b'El.. ' A LAYOUT WHICH WOULD : f v T HEAD LQCAT IONS AL POSSIBLE. THIS CONTRA TOR S LAYOUT MUST COMPLY WITH ALL- APPLICABLE CODES AND THE LANDLORD'S REQUIRE' NTS. ( -HEADS NOTED ON THIS DRAWING AS 'NEW' MUST 5E 'INSTALLED WHERE SHOWN.) SUBMIT SIX COPIES OF TAPE DRAWINGS TO THE LANDLORD'S INSURANCE UNDERWRITER FOP, APPROVAL SUBMIT TWO COPIES OF THE APPROVED, DRAWINGS TO THE LANDLORD AND TWO COPIES TO AMERICAN EAGLE OUTFITTERS. 7. ALL SPRINKLER WORK TO BE PERFORMED BY THE LANDLORD. TIE r XI" TIN;:n SPACE SPACE !S BELIEVED TO BE FtFULLY SPRINECL1wRED. ©u � �. THE HEAL) LA t OU 1 UNKNOWN. THIS DRAT. HNC" P4I ' -;�' ;N E LAYOUT. I <OINEVF ; THE LANDLORD'S CON S UL m%; .NS EC HE SPACE- !R?1 N1' THE EXI57lNG HEAD LOCATli" A LAYOUT 6r1bIICH WCtlLD UTILIZE: AS MAY . ''ISTING HEAD LOCATIONS AS :POSSIBLE T1 15 LAYOUT MUST C01`1- E Y WITH ALL APPLICABLE WOES AND THE LANDLORD'S QLIREMEN T . (HEADS NOTED ON THIS DRAXING AS 'NEW' MUST SE INSTALLED li4H LT E SHO N, ) SUBMIT TWO COPIES OF THE APPROVED DRAHINas TO AMERICAN N EAGLE OUTFITTERS. THIS CONTRACTOR SH AND RETURN LINES AS ACCORDANCE WITH TH 1i. EXTEND LANDLORD'S F I5. THIS CONTRACTOR SH LANDLORD. ALL REFRIC THIS CONTRACTOR SH,i. EXISTING CONDENSING ?;. THE LANDLORD WILL INSTALL A COMPLETE SPRINKLER :SYSTEM AT AMERIC:A,N EAGLE OUTFITTERS EXFE:' SF . °ri"- L SE ENGINEERED BY THE LANDLORD AND APPRO ., - o`, RP FfbF,LI ANCE RATING WARDS OR, kr` , i CONSTRUCTION. ANY FABRICATED . `_ .. : R�� � : S'1 °�E C�NST'RUC ; i0�- 1..�:I�`r" ALTERATIONS TO SYS I EM TO CONFORM TO TENANT'S °R.EOU1REMt. NTS WILL t:, ; BY THE LANDLORD'S SPRINKLER CONTRACTOR AT TENANT'S EXi' NS . q, THE iEX'iSTING CHILLED/- WATER AIR HANDLER SYSTEM SHALL BE REUSED. � THIS CONTRACTOR SHALL VF Iry T1-.7 CAPACITY, AND SUITAEiiLI p p r OF ALL HVAC ITEMS A :.. t N E� 11 .� ,E5 TO AMERICAN EAGLE OUTFITTERS (WE COIL : , I L ". i SEE SPECS. ADJUST UNIT .!_C DELIVER -- CFM AND BTUH COOLING. NOTIFY AMERICA{ EAGLE OUTFITTERS IMMEDIATELY IF THE EXISTING EQUIPMENT CANNOT PROVIDE: EVEN, EN, RELIABLE COOLING AT THE CONDITIONS NOTED ON THE CHART. 10. AMERICAN EAGLE OUTFITTERS SHALL P nF FAR THIS C:ONT RA,cTOR TO INSTALL A NEW AIR H I: I T I+ T°` 11 "' / -,.,_ WATER COIL(;-) Of SUFFICIENT SIZE TO AC t~ ! ! ! SPACE, UN r' ,.ALL Br_: MOUNTED IN ACCORDA. : i, d S AND THE LANDLORD Ra2UIREMEN; T S PROVIDE NECESSARY STRUCTURAL REINFORCING. SEE- THE SPECS ANt CHART' ON THIS DRAWING. 12. THE EXISTING SPLIT TY CONTRACTOR SHALL V, ALL HVAC ITEMS AND OUTFITTERS. SEE SPECS. ADJUST UNIT I5. AMERICAN EAGLE OUTFITTERS SHALL- INSTALL A NEVI SPLIT ROOM MOUNTED AIR W CONDITION THE SPACE. LL BE MOUNTED IN ACCORDANCE WITH LANDLORD REQUIREMENTS. PROVIDE NECESSARY STRUCTURAL R,EINFoRcING AND PREFAB ROOF isUR3. SEE THE SPECS A Ir? ''HART ON •rt11S DR,toAINC . 17. THiS CONTRACTOR 5-ALL INSPECT THE EXISTING VAV X(E9), ETC. AND SHALL AD` AMERICAN EAGLE OUTFITTERS IN kR!TlNC OF THE MANU- FACTURER, MODEL NO _ PF I I=, ,, 1-._ l C. THIS CONTRACTOR �I4ALL M FURNISH AND IN',,TA1 L T 01 6 N R Ev RUED O STRc A . FEELS THAT THE E7,QUIPMEi1T OF THESE VAV BOXES. I, CANNOT PROVIDE ADEQUATE LING, HE SHALL NOTIFY ,AME t :AN EAGL OUTFITTERS IMMEDIATELY. Z THE LANDLORD NILL FURNISH AND INSTALL THE VAV Box AT THE APPROXIMATE L CHAT! ' ..t r1�1E IS`rING BOXES ARE SUITABLE FOR a CFM ' l IS , - �.T SHALL FURNISH AND INSTALL THE APPROXIMATE LOCATIONS SHOWN. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL DUCTWORK SHOWN OR REQUIRED FROM THE MALL SUPPLY AIR DUCT TO THE VAV BOXES, AND DOWNSTREAM OF TI-IE VAV BOXES. COORDINATE. ALL WORK WITH T LANDLORD, Iq. TI-IIS CONTRACTOR SHALL FURNISH AND INSTALL THE NEW VAV BOXES AT 20. THIS CONTRACTOR SHALL PURCHASE AND INSTALL THEM A 'L.ONTRACTOR SHALL FL REQUIRED FROM THE M .'_ DOWNSTREAM OF THE VAV BOXES HILLED /___ WATER SUPPLY ULATION TO BE IN Im r ENTS AND SPECIFICATIONS 23. TENANT SHALL PROVIDE AND THIS CONTRA AIR CONDITIONING UNI SPACE. UNIT SHALL BE REQUIREMENTS. M.C. REUSED. ' Ili crrY, AND U! i•Ae i L: `` .: i TO AI1ERI.CAN EAGLE TO DELIVER . a CFM. C I = THIS CONTRACTOR TO OF CONDENSING UNIT AND L- TO ADEQUATELY 'IDLER AS SHOWN. FRIGERANT LINES WITH ;TED. r s CONTROLLER ON THE NEAI v ;'<is FROM THE L,A.Nr.Lor+ D EMS SHORN. THI :: JCTWOi K SHOWN OR si UCT TO THE VAV PDXE 3, AND 21. THE _EXISTING ROOFTOP HVAC SYSTEM MAY BE REUSED. Ts;IS CONTRACTOR SHALL VERIFY THE CONDITION CAPACITY r, c.'IIT - r"( OF ALL_ HVAC I"ITE.M5 AND REPORT ANY DEFr -;.E OUTFITTERS. SEE ADJUST UNIT TO DELIV .F A D F �; AS SCHEDULED. NOTIFY AMERICAN EAGLE CUTE' - I ,- t.LY IF THE FISTING EQUIPMENT CANNOT PROVIDE ADEQUATE, EVEN, RELIABLE COOLING AT THE CONDI TIaNs NOTED ON THE O -IAfT, 22. THIS CONTRACTOR SHAH SPACE AND DETERMIN IF NOT SO EQUIPPED, AMOUNT TO BE ADDED TO THE s ONa 1IZER. HVAC SYSTEM SERVING 1 HIS 'PEL) WI Th AN Er L:QiNOrli, .ER. A .SE 1.. AS ALTERNATE E NO. 1 THE BASE BID FOR FURNISH -ZING AND iNSTALLiNG AN ALL INSTALL A NEN wc)OFTC' P EC UATELY CONDITION -r =1E III - rH THE LANDLORD fir r - ��- _ _ CE ARY STRUcTuRAL RE.iNFO C!Nt• AND INSTALL TENANT SUPPLIED PREFAB ROoF CURB. SEE SPECS AND CHART° I,)N THIS DRAWING. 24. TAE LANDLORD HILL FURNISH AND INSTAL' APPR '(MATE L OCA T '' y l ( !N5l"ALL ALL DUCT( a ALL. WORK WITH THE E R Iw 25. THIS CONTRACTOR SHALL INSTALL THE THERMOSTAT WHERE SHOWN ON THE DRAWING, AND ALL CONTROL WIRING. .26, THIS CONTRACTOR c THE DRAWING AND A ATF 2 ("HIS CONTRACTOR, SHALL OBTA N AND AL.L INSTALL THERMTAT(S) TO ALL POWER WIRING A,rou Cdl FCT!ONS. E s'I OSTAT(S) WHERE SHOWN ON :G )ofl - OP HVAC UNIT AT THE OR SHALL FURNISH AND Er . R TUTS SYSTEM. (X RDINATE " FROM THE LANDLORD INC. EXTEND WIRING FROM G ARY CONNECTIONS. PROVIDE 28. THIS CONTRACTOR SHALL COOPERATE AND COORDINATE WORK WITH THE LANDLORD AND THE E.C. AND OTHERS AS REQUIRED TO PROVIDE A FULLY OPERABLE COOLING AND I- (EATING SYSTEM- THIS CONTRACTOR SHALL PROVIDE ANY ADDITIONAL WORK OR MATERIAL REQUIRED. 2q. ALL DUCTWORK SHALL BE WRAPPED WITH INSULATION PER THE SPECIFICATIONS. 30. ALL NEW DUCT INSULATION SHALL BE USED IN ACCORDANCE WITH THE SPECIFICATIONS AND OTHER NOTES ON THE DRAWING. REPAIR ANY DAMAGED INSULATION AND INSULATE ANY NEW DUCTS. EXISTING DUCTWORK INSIDE THE SPACE MAY BE REUSED IF IN GOOD CONDITION, THE PROPER SIZE, AND PROPERLY INSULATED. SEE SPECS. 31. ALL DIFFUSERS AND GRILLES SHALL MATCH THE CEILING AS INDICATED ON THE ARCHITECTURAL DRAWINGS. 32. ALL BRANCH TAKE -OFFS TO HAVE A MANUAL DAMPER. 33. THIS CONTRACTOR SHALL FURNISH AND INSTALL A NEW TOILET EXHAUST FAN/ SYSTEM AS SHOWN ON THE DRAWINGS AND CALLED FOR IN THE SPECS. 34. THIS CONTRACTOR Sr FITTING ROOMS AS SI 35. THE " 'iSTING TOILE CLEANED, INSPECTED BALANCE. 36. EXTEND EXHAUST DUCT FROM TOILET ROOMI(S) TO LANDLORD'S COMMON EXHAUST DUCT SYSTEM BY M.C. INCLUDING CONNECTION TO LANDLORD'S DUCT. 7. EXISTING EQUIPMENT N1i e r- - e1F. : AND REMOVED. CAP - ~ UC' :., PI REQUIRED. P 'YE. THE EXISTING PLUMBING SYSTF F,: i'.`I�. T ROOM 5�1ALL BE REUSED. THIS CONTRACTOR S, ! ! " ?; °" A L Ii 'ING, DRAINS, FIXTURES, AND WATER HEATERS ARE �'� E� :1 :�. NOTIFY AMERICAN EAGLE OUTFITTERS' REPS ; i-i i .A ! IVE OF ANY ITL ; a W MC i ARE IN QUESTIONABLE CONDITION, REPLACE AS DIRECTED. INSTALL FLOOR DRAIN IN NONE IS EXISTING, (INSTALL MIXING FAUCET, 3c1, THE 1:XSTING' PLUMING THIS CONTRACTOR 5. A WATER HEATERS ARE OUTFITTERS' REPREES. . rt CONDITION. REPLACE AS DIRECTED. S"I STEr'1 r' IAL, AN EXHAUST SYSTEM FOR THE ID CALLED FOR IN THE SPECS. EUSED SHALL SE CalPLETELY ALL FAN BELTS, ADJUST AND -CT DISCONNECTED I S��Lw BE D COI N . EC►ED ROOF OPENINGS AS 'SED AS MUCH AS POSSIBLE, L' �? ING, DRAINS, FIXTURES, AND <17: NOTIFY AMERICAN EAGLE ! 6 TENS WHICH ARE IN QUESTIONABLE 40. THIS CONTRACTOR SHALL VERIFY WITH THE LANDLORD THE EXACT LOCATION FOR SANITARY TAP IN. PATCH ALL CONCRETE INSIDE AND OUTSIDE THE SPACE AS REQUIRED BY THE NEW SANITARY SYSTEM. 41. M.C. SHALL FIELD VERIFY EQUIPMENT LOCATIONS AND COORDINATE DUCTWORK INSTALLATION WITH EXISTING MECHANICAL LINES. 42. THIS CONTRACTOR SHALL COORDINATE WITH THE LANDLORD AND WITH THE G.C. FOR THE PROVISION OF OPENINGS IN THE DEMISING WALLS FOR RETURN AIR. VERIFY NUMBER, SIZE, AND LOCATION REQUIRED. ALL OPENINGS TO WAVE 1 "x1" WIN MESH SECURITY SCREENS. .4 :5) THE EXISTING SPLIT SYSTEM SHALL BE RECONDITIONED AS FOLLOWS: -CHEMICALLY CLEAN, CONDENSER, AND EVAPORATOR COILS. ..FRI SURE CLEAN FAN SCROLLS, BLOWER ASSF.M LY AND HOUSING. rC.HEC; ENTIRE UNIT c°'E, .:. . : :J E SHEET METAL PANELS AND FRAMEWORK NITI-4 NE N R 0, - CK 'r L.D AS ;EE'CESSAR.Y. -CHECK CONDENSATE DRAIN AND PIPING FOR PROPER DRAINAGE AND LEAKS REPAIR OR REPLACE AS NECESSARY TO PROVIDE LEAK FREE OPERATION. ••-REPLACE FILTERS WITH WEN FARR 50/Ft..0 DISPOSABLES OR REPLACE MEDIA ON UNITS EQUIPPED WITH FILTER FRAME. RACKS. --CHECK BLOIAER SHAFT AND BEARING-LUBRICATE AND/OR REPLACE IF -REPLACE ALI.- BELTS. -ADIUST BLOWER RPM AS REOUIRE.D. --.CL.EAN INSIDE. AND ouTsiae oF UNIT, SAND, ToUCH PAINT ANY BARE OR RUSTED AREAe., --CHECK AND VERIFY PROPER OPERATION OF MODULATOR DAMPER,. MOTORS- DAMPERS, AND LINKAGES. --CHECK COMPRESSOR OPERATION-INCLUDE AMPERAGE AND mE,G RE.ADING5. --vERFY THAT REFRIGERATION PRESSURE.S ARE WITHIN MANUF-ACTURER5 SPECIFICATION FOR EFFICIENT OPERA,TION, -CHECK OIL FOR Aco usiNC APPRoVED oli,. TEST KIT-NOTIFY AMERICAN EAGLE OUTFITTERS IF ACID TES-T INDICATES UNACCEPTABLE CONTAMINATION. -CHECK ALL, C.:ONTROLS AND SAFETY DEVICLiS-VERIrr PROPER OPERATION- li ALL THERMOSTATS, HIGH ,AND LON PRESSURE SAFETIES .- r,. , s. ••VERr( AMPERAGE DRAW IS i.41ITHIN PLATE DATA ON ALL MOTORS. -INSPECT AND TIGHTEN ALL CCI-NTROL. AND LINE VOLTAGE C.ONNECTIONS AND -CHECK SHEAVES AND PULLEYS FOR .r.INLISUAL IAIF-AR .AND ALIGNMENT- REPLACE OR ADJUST AS NEEDED. --cHECK ELEC'TRIC HEATERS, CONTROLS AND SAFETY DEVICES (IF APPLICABLE) -PROVIDE WRITTEN REPORT TO AMERICAN EAGLE OUTFITTERS ON ALL WORK PERFORMED, NOTE' MAKE, MODEL, CFM :3E AMFERAGE AND REFRIGERANT READINGS; PROVIDE RESULTS OF OIL_ ACID TESTING AND Nare ANY UNUSU.AL CONDITIONS OR FINDING, 44. 1 EXISTING ROOFTOP UNIT SHALL BE RECONDITIONED AS FOLLOWS; -CHEMICALLY CLEAN, CONDENSER AND EVAF'TOR COILS. -FRE5.2SURE C.LEAN FAN -SCROLLS, BLOWER ASSEMBLY, AND I-IOUSING. ...0.-IECK ENTIRE UNIT .A!cASEE, N - .,..,ThSHEET METAL PANELS AND FR.AMENORK WITH NE \, T h 'RE-, f. T Cl< ' 71_,D AS NECESSARY. TX -C.H.E'CK CONDENSATE DRAIN .AND PIPING FOR PROPER DRAINAGE AND LEAKS. REPAIR OR REPLAC.E A,S NECESSARY TO PROVIDE LEAK FREE OPERATION. -REPLACE. FILTERS WITH NEW FARR 30/30 olsposAsLEs OR REPLACE MEDIA ON UNITS EQUIPPED WITH 'FILTER FRAME RACKS. -CHECK BLOWER SHAFT ANT.) BEARING-LUBRICATE ANDIOR REPLACE NECESSARY, -REPLACE ALL. BELTS. ADJUST BLOWER RPM AS REQUIRED. .. •CLEAN INSIDE AND OUTSIDE UNIT RUSTED AREAS, -CHECK AND VERIFY PROPER OPERATION OF MODULATOR DAMPER MOTORS ORS DAMPERS, AND LINKAGES. -CHECK COMPRESSOR OPERATION - INCLUDE AMPERAGE AND MEG READINGS. -VERIFY THAT REFRIGE.RATION PR.ESSLIRES ARE WITHIN MANUFACTURERS SPECIFICATION FOR EFFICIENT OPsATION, -CHECK OIL FOR ACID USING APPROVED OIL TEST KIT-NOTIFY AMERICAN EAGLE OUTFITTERS IF ACID TEST INDICATES' UNACCEPTABLE CONTAMINATION. -CHECK ALL CONTROLS AND SAFETY DEVICES- VERIFY PROPER OPERATION- INCLUDES ALL THERMOSTATS, HIGH AND LOW PRESSURE SAFETIES ETC. C. -- VERIFY AMPERAGE' DRAIN IS WITHIN PLATE DATA ON ALL MOTORS. -INSPECT AND TIGHTEN ALL. CONmoL AND LINE VOLTAGE alNNECTIONS AND WIRING- REPLACE WIRING AS NEEDED. -CHECK IEAV ES AND PULLEYS FOR UNUSUAL WEAR AND ALIGNMENT - REPLACE OR ADJUST AS NEEDED. -CHECK ELECTRIC HEATERS, CONTROLS AND SAF DEVICES (IF APPLICABLE) -CHECK GAS CONTROLS, HEAT EXCHANGERS,, BURNERS, PILOT, IGNITION VALVES AND SAFETY CONTROLS (IF AFPLICABL -PROVIDE i,�IRITTE REPORT EPtT TO AMERICAN EAGLE OUTFITTERS ON ALL i�°1O•. lK PERFORMED, NOTE MAKE, MODEL,, CFI`1 SETTING, AMPERAGE AND REFRIGERANT READINGS; PROVIDE R :SU.L T S OF OIL ACID TESTING AND NOTE ANY UNUSUAL CONDITIONS OR FINDING. IF .AND, POUCH -UP PAINT ANY BARE OR 45. THE EXISTING CHILLED /-- WATER SYSTEM IS TO 3E RECONDITIONED AS FOLLOWS: r - CHEMICALLY CLEAN CH A T% CO -PRESSURE CLEAN FAN • •01.'1`, AND HOUSING. - CHECK ENTIRE UNIT ASS` wLY" AND RESECURE s4-IE r METAL PANELS AND FRAMEWORK WITH NEW FASTENERS OR 'TACK WELD AS NECESSARY. -CHECK CONDENSATE FAN AND INSULATION LININ S -- REPLACE AS NEEDED. -CHECK CONDENSATE DRAIN AND PIPING FOR PROPER. DRAINAGE AND LEAKS. REPAIR OR REPLACE AS NECESSARY TO PROVIDE LEAK FREE OPERATION. - REPLACE FILTERS WITH NE1-AI FARR 8O /! O DISPOSA's II..,FB OR REPLACE MEDIA ON UNITS EQUIPPED WITH FILTER FRAME RACKS. -CHECK BLOWER SHAFT AND BEARING-LUBRICATE AND/OR REPLACE IF NECESSARY. - REPLACE ALL BELTS. - ADJUST BLCSWER RPM AS REQUIRED. -CLEAN INSIDE AND CUTSIDE OF UNIT, SAND, TC-)UCH- UP PAINT ANY FARE OR RUSTED AREAS. - CHECK AND VERIFY PROPER OPERATION OF MODULATOR ATOR DAMPER MOTOR DAMPERS, AND LINKAGES. - VERIFY AMPERAGE DRAW IS WITHIN PLATE DATA ON ALL MOTORS. - INSPECT AND TIGHTEN ALL CONTROL. AND LINE VOLTAGE sE C NNECTION w AND WIRING-REPLACE WIRING AS NEEDED, - CHECK SHEAVES AND PULLEYS FOR UNUSUAL WEAR AND ALIGNMENT- REPLACE OR ADJUST AS NEEDED. -CHECK ELECTRIC HEATERS, CONTROLS AND SAFETY DEVICES (IF .APPLICABLE) -CHECK COILS FOR LEAKS. - INSULATE ALL CI- TILLED /-,,,, WATER PIPING. - INSTALL THERMOMETERS ON SUPPLY AND RETURN LINES, -CHILLED/L._ PIPING, CONTROLS, ROLS, AID GAUGES SHALL SE BROUGHT INTO COMPLIANCE WITH THIS DRAWING. - REPLACE CONTROL VALVES, BYPASS VALVES, STRAINERS. - PROVIDE WRITTEN REPORT TO AMERICAN EAGLE OUTFITTERS ON ALL WORK PERFORMED, NOTE MAKE, MODEL, CFM SETTING, AMPERAGE AND REFRIGERANT READINGS; PROVIDE RESULTS OF OIL ACID TESTING AND NOTE ANY UNUSUAL CONDITIONS OR FINDING. 46. THE EXISTING VAV BOX(ES) SHALL BE RECONDITIONED AS FOL! O S -CHECK ENTIRE UNIT .ASSEMBLY AND RESECURE SHEET ME'I PANELS AND FRAMEWORK 1NITW NEW FASTENERS OR T ) ,-H - UP NECE S ARY. T. -CLEAN INSIDE AND Ot. .c i a1T c 4L -UP PAIN 1: ANY FARE OR RUSTED AREAS. -CHECK AND VERIFY PR A A't i ita'O? MODULATOR DAMPER MOTORS DAMPERS, AND LINKAGES. - INSPECT AND TIGHTEN ALL CONTROL AND LINE VOLTAGE C NNEC E "IONS AND WIRING - REPLACE WIRING AS NEEDED. -CHECK ELECTRIC RIC WEATERS, CONTROLS AND SAFETY DEVICES (I?- .APPLIC.ABLE) - PRESSURE CLEAN HOT IIIATER REHEAT COIL. (IF AAP'PLICA BI-F• ) -CHECK HYDRONIC VALVE REPLACE IF NECESSARY (IF APPLICABLE) - CHECK DAMPER MOTOR OPERATION- A,I::JUST AS REQUIRED, - VERIFY PROPER OPERATION OF DAMPERS. -CHECK LINKAGE AND LUBRICATE-REPLACE AS REQUIRED. -CHECK VELOCITY RESIT' CONTROLLER AND A C.TL'.A, oris - VERl%'r r"FC'i'a,R OPERATION (IF APPLICABLE) - ADJUST MAXIMUM AND MINIMUM CFM SETTING € ER SPECIFic" .'i IONS ON THIS DRS $III G. -- PROVII IrIRITTEEN REPORT T T AMERICAN EAGLE OUTFITTERS ON AL!. WORK PERFORMED, NOTE MAKE, MODEL, CFM �i".,+ � i IN.A AMPERA ^wE AND REFRIGERANT READINGS; PROVIDE R ESULTS OF OIL ACID TESTING . -AND NOTE ANY UNUSUAL CONDITIONS OR FINDING. 47. IF REQUIRED BY THE LANDLORD OR LOCAL BUILDING CODES, THIS CONTRACTOR SHALL COOPERATE WITH THE E.C. TO FURNIa1 -I AND INSTALL A FIRE AND SMOKE DETECTION SYSTEM INCLUDING BUT NOT LIMITED TO, SMOKE DETECTORS, SMOKE EXHAUST FANS, VISUAL AND AUDIBLE ALARMS, ETC. ALL EQUIPMENT MUST BE FULLY OPERABLE AND MEET LANDLORD AND LOCAL BUILDING CODE REQUIREMENTS. CONTACT THE AMERICAN EAGLE OUTFITTERS REPRESENTATIVE WITH ANY DISCREPANCIES OR MISUNDERSTANDINGS. 4E. ALL ROOF WORK SHALL , �aNDLO D'S REQUIREMENTS. ROOF WORK TO BE PER 1Ai L ..r ''S ROOFING CONTRACTOR AT THIS CONTRACTOR'" L:,w 4q. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS AND /OR RECOMMENDATIONS, AND GOOD INDUSTRY STANDARDS. IF THERE IS A CONFLICT, CONTACT AN AMERICAN EAGLE OUTFITTERS REPRESENTATIVE IMMEDIATELY. SD -2 SHALL SE PROVIDED WITH MP -35 INSULATED PLENUM SOX. NOTE: ALL SUPPLY DIFFUSERS AND RETURN GRILLES ARE FURN. BY TENANT, INST. BY M.C. pos NOTE: IF THE STOCK ROOM DOESN'T HAVE A CEILING, THE STOCK ROOM DIFFUSERS MUST HAVE BORDER 1:t-6 PROVIDED. NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. WsLIlek[ Working Drawing Review ic Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and /or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir • to be kept on the job site at all times. 1 /3/33 Si•ned Date FAN POINIERED VAV BOX SCIL- (SOULS MARK FPVAV -1 MANUFACTURER AND MODEL NO. TITUS DTFS -16 TYPE ❑ VAV ® FAN POWERED VAV SOX ❑ CAV TYPE OPERATION ❑ PNEUMATIC ® ELECTRIC ❑ SYSTEM POWERED ❑ FURN. SY M.G. ❑ FURN. SY L.L. ❑ RURCI -I. FROM L.L. ❑ INSTALL SY L.L. ® NEW ❑ EXISTING PRIMARY AIR CFM CAPACITY MIN 0 MAX 4000 ADJUST BOX TO CFM MIN 0 MAX 4000 INLET SIZE 16" DIA MOTOR H.P. 3/4 VOLTS 277 -I -60 ELEC HEAT KW N/A VOLTS N/A - 1 CITY RECEIVED I FEB B 4 Zfic3 PEFIMIT CENTE Drawing No. .02 Chvac - Full Commercial 1-1VAC Loads Calculation Program Kegley Design Inc J Portersvitle, PA 16051 j Erne Software Development, Inc. Aerie 2751 Page 2 General Project Data Input (cont'd) ] hr 3 Internal Operating Load Profiles (C = 100) hr hr 2 hr 3 hr • hr hr hr hr hr hr hr 11 r hr • hr hr hr , hr hr hr • hr hr hr hr I hr I hr 1 4 5 a 7 8 9 10 ' 12 13 14 15 C C C C C 16 17 18 19 20 21 22 : 23 24 1 2 3 4 5 S ICCCGC.CCCCCOCCCCCCCCCCCCC 8 e 10 C C CCCCCCOCCCCCCCC CCC, C CCCCCCCCCCCCC'CC CCCCC•CCCC'CCCCCC C C C C C C C C C Ci C C C C C C C C C C C C cc C C C C C C C C C C C C C C C C C C C C C C C C; C C C C C Cr C C C C C C C C C C c C C C C C. C C C C C C C CC CCCCCCC'CC C C C C C C c'c CCCCCCCCC C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C cc C C C C C C C C C C C C C C C C C C C C c Chvac - Full Commercial HVAC Loads Calculation Program Negley Design Inc Portersville„ PA 16051 General Project Data Input r General Project Information Project file name: Project title: Project date: Project location: Barometric pressure: Altitude: Latitude: Mean daily temperature range: Starting & ending time for HVAC load calculations: Number of unique zones in this project Building Default Values Calculations performed: Lighting requirements: Equipment requirements: People sensible load multiplier: People latent load multiplier: Zone sensible safety factor. Zone latent safety factor: Zone heating safety factor: People diversity factor: Lighting profile number Equipment profile number People profile number: Building default ceiling height: Building default wall height C.'sProgra m FifestElite1Chvacwi.ProjectslAerie2751,CHV Dec 20 07 10:00a Negley Design Inc. Chvac - Full Commercial HadLoads Calculation Program Negley Design Inc Portersville, PA 16051 Zone In put [Zone 1: Sales/Fitting (3473.2 sq.ft) (Group 0) Air Handler number: Zone length: (feet) Lighting Wafts: Number of people in zone: Lighting profile number: Ceiling height (feet): Sensible safety factor (%): Sensible heat per person (Stull): Cooling ventilation method: Cooling infiltration method: Heating ventilation method: Heating infiltration method: Winter exhaust air CFM: Minimum supply CFM: Coil. exposed to plenum (sell); Both heating and cooling loads are calculated for this zone. CAP rog ram Files\ El itetChva cw\ ProjectskAerie2751.CHV 1 86.83 9,458 46 0 12.00 5 250 CFNI/sql CFM/sq.ft CFMisq.ft CFM/sq.ft 0 0 3,473 Zone 2: Stock (586 sq.ft) (Group 0) Air Handler number: Zone length: (feet) 14.65 Lighting Watts: 655 Number of people in zone: 0 Lighting profile number: 0 Ceiling height (feet): 12.00 Sensible safety factor (%): 5 Sensible heat per person (Beuh): 250 Cooling ventilation method: CH/beget Cooling infiltration method: CFM/sq.ft Heating ventilation method: CFM/sq.ft Heating infiltration method: CFM/sq.ft Winter exhaust air CFM: 0 Minimum supply CFM: 0 Cell. exposed to plenum (sget): 586 Both heating and cooling loads are calculated for this zone. C:\Program FileslElite‘Clevacw\ProjectslAene2751.CHV Aerie 2751 Wednesday, December 19, 2007 TACO/VIA, WASHINGTON, USA 29.491 400 47 26 9arn lOpm 2 7 24- 3613-61 34 ln.Hg. feet Degrees Degrees Zone occurrences: Zone width (feet): Equipment Watts: People profile number: Equipment profile number: Heating safety factor (%): Latent safety factor (%): Latent heat per person (Btuh): Cooling ventilation value: Cooling infiltration value: Heating ventilation value: Heating infiltration value: Summer exhaust air CFM: Latent Btuh equipment load: Exposed floor slab perimeter (ft): 1 Zone occurrences: Zone width (feet): Equipment Watts: People profile number: Equipment profile number: Heating safety factor (%): Latent safety factor (%): Latent heat per person (Btuh): Cooling ventilation value: Cooling infiltration value: Heating ventilation value: Heating infiltration value: Summer exhaust air CFM: Latent Stub equipment load: Exposed floor slab perimeter (ft): Elite Software Development, Inc, Aerie 2751 Page 1 1 40.00 4,000 0 0 10 5 200 0.000 0.000 0.000 0.000 0 0 0 Both healing and cooling loads 0.00 Watts per square foot 0.00 Watts per square foot 250 Btuh per person 200 Stub per person 5% 5% 10 % 100 % 0 0 0 12.00 feet 17.50 feet Wednesday, December 19, 2007, 9:49 AM p• 5 Elite Software Development, Inc. Aerie 2751 Page 4 1 40.00 0 0 10 5 200 0.000 0.000 0.000 0.000 0 0 0 Wednesday, December 19, 2007, 9:49 AM Building-Level Design Conditions Outdoor Outdoor Dry Bulb Wet Bulb Design Month August June July September January February Winter Skin Loads Lighting Equipment People Partition Cool. Pret. Heat. Prat. Cool. Vent. Heat. Vent. Cool. Intl. , Heat. Intl. Draw-Thru Fan Blow-Thru Fan Reserve Cap. Reheat Cap. Supply Duct Return Duct Misc. Supply Misc. Return Building Totals Building I Summary Ventilation Infiltration Pretreated Air Zone Loads Plenum Loads Fan & Duct Loads 10,113 4,000 46 a 0 0 a 0 0 0 0 0 0 0 0 a 0 Building Totals 0 87 66 84 64 89 67 79 62 56 52 59 50 21 C:\Progrem Piles\eriteAChvaowNProjectskAerie2761.CHV Dec 20 07 10:00a Heg1ej Design Inc. Chvac - Full Commercial HVAC Loads Calculation Program Negley Design Inc Portersville, PA 16051 Building Summary Loads Building peaks in February at 10pm. Bldg Load Area Sen %Tot Lat Sen Descriptions Quan Loss Loss Gain Gain Roof 0 0 0.00 0 0 Wall 0 0 0.00 0 0 Glass 0 0 0.00 0 0 Floor Slab 0 0 0.00 0 0 i Check Figures Total Building Supply Air (based on a 20° TD): Total Building Vent. Air (0.00% of Supply): Total Conditioned Air Space: Supply Air Per Unit Area: Area Per Cooling Capacity: Cooling Capacity Per Area: Total Heating Required With Outside Air Total Cooling Required With Outside Air: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C:\Program Fi4elEiite\CIrp.tecvbr\Projecis'Aetie.2'75 0.00 Indoor Rel.Hum 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 50% 50% 50% 50% 50% 50% 9,660 72 4-368-B134 0 0 0 9,660 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2,889 CFM 0 CFM 0 Btuh 6.02 Tons Indoor Dry Bulb 75 75 75 75 75 75 75 Wednesday, December 19, 2007, 9:49 AM 0 0.00 9,660 62,638 72,298 100.00 Sen %Tot Lat Sen Net %Net i Loss Loss Gain Gain Gain Gain I O 0_00 0 0 0 0.00 0 0.00 0 0 0 0.00 C 0.00 0 0 0 0.00 0 0.00 9,660 62,638 72,298 100.00 0 0.00 0 0 0 0.00 O 0.00 0 0 0 0.00 62,638 4,059 Sq.ft 0.7116 CFMISq.ft 673_7418 Sq.ftiTon 0.0015 Toris/Sq.ft a 36,232 14,331 12,075 0 0 0 0 0 0 0 0 0 0 a 0 0 Grains In/Outdoor Duff Correction - 2.25 - 7.25 - 0.39 -8.65 -13.57 -25.74 Elite Software Development, Aerie 2751 I Page 51 Net Gain 0 0 0 0 72,298 0 36,232 14,331 21,735 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 p.6 Wednesday, Decembes 19, 2007, 9:49 APIA -8 - 11 - 16 - 39 -36 %Net Gain 0.00 0.00 0.00 0.00 0.00 50.12 19.82 30.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 100.00 - Chva . :Flail Commercial - HVAC Loads Calculation Program Negley Design Inc Portersville. PA 16051 Air Handler Input Air Handler Number 1 Input Data Name: Terminal type: Supply fan type: Calculations performed: Excess supply air: Occurrences: People profile number: Lighting profile number: Equipment profile number: Exhaust may not exceed supply air Leaving heating coil temp (deg.F): Leaving cooling coil temp (deg.F): Cooling coil CFM Misc. Btuh gain -supply side: Misc. Btuh gain - return side: Combined fan & motor efficiency Static pressure across fan (in.wg.): Summer supply duct temp rise (deg.F): Summer return duct temp rise (deg.F): Winter supply duct temp drop (deg.F): Winter return duct temp drop (deg.F): Chilled water temp difference (deg.F): Hot water temp difference (deg.F): Cooling ventilation: Cooling infiltration: Heating ventilation: Heating infiltration: Pretreated outside air: Pretreated air Summer DB (deg,F): Pretreated air Summer WB (deg.F): Pretreated air VI/inter DB (deg.F): Design Month August June July September January February Winter Outdoor Dry Bulb 87 84 89 79 56 59 21 Outdoor Wet Bulb 66 64 67 62 52 50 C:1Program Files%Elite%Chvacw\Projects\Aerie2751.CHV Unit 1 Variable Air Volume Packagie fan Both heisting and cooling loads Reserve 1 0 0 0 No 90.0 55.0 0 0 0 0.00 0.000 0.000 0.000 0.000 0.000 0.000 CFM/sq.ft 0 CFM/sq.ft 0 CFM/sq.ft 0 CFMIsq.ft none 0 0 0 Indoor Rel.Hum 50% 50% 50% 50% 50% 50% Indoor Dry Bulb 75 75 75 75 75 75 75 Elite Software Development, Inc. Aerie 2751 Page 3 Grains Diff -2.25 -7.25 -0.39 -8.65 -13.57 -25.74 In/Outdoor Correction -8 -11 -6 -16 -39 -36 Wednesday, December 19, 2007, 9:49 AM Si ned Date I • • : • • ;.• strireq° 1 Drawn. . Drawing No. M.0.2a RECEIVED CITY OF TUKWILA FEB 0 4 Fa PERMIT CENTER Wstfiek Working Drawing Reyie Approved Approved as Noted 4 4( CI Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir • to be kept on the job site at all times. 1/3/08 in in 0 D. L 4 " U - S • 5 tO nos No. ES.O.1 tata II. GENERAL ELECTRICAL TRADES SPECIFICATION NOTE: The Electrical Trades Specification is divided into two parts I. SUPPLEMENTAL ELECTRICAL TRADES SPECIFICATIONS defining the scope of wa-k end the special miter ice and equipment for this project; II. GENERAL ELECTRICAL TRADES SPECIFICATIONS defiin'ng the standard requirement* and materials. If the Supplemental Specification is not attached, contact the Tenant immediately. GI. GENERAL All work included order this headng is to be subject to the Instructions to Bidders and General Ccrdit'lons herein before Witten or Warred to for the entire work. This shall include all wiring, conduit, electrical service, and distribution ec aliment, lighting, amei mfecellareaus eepalpment detailed en the drawings, or rewired far a complete and eperoble Installation. (Note: See drewiles For items famished and/or installed by others. All final corrections by this Centraeter.) THs Contractor shall furnish all labor end materials ad ietall all egaiprne nt as called for in these specifications, and shown an the plans, or as may be reasoeably implied by either, for the installatim of the complete electrical oyster'. (d) All nark shall be in strict camplance codes, including but not limited ton: NEC, 8OCA, LIEC, ADA, SECCI, federal cadge, state codes, local codes, OSHA, NFPA, Lire Safety codes, etc. all of current issue. All work shall meet the regpfreamants and regulations of Underwriter's Laboratories, and local utility companies. All egiipmerit slab be approved and labeled by appropriate industry testing agencies, including but not limited to ; lkdruriters Laboratories, Factory Mutual, AGA, etc. All ware ad egripment shall be sized end installed in aeco -deuce with appropriate industry standards ad regulations erganizatiens but riot limited to NEC, U.L., Factory Mutual, ASHRAE, NFPA, ANSI, ASME, AGA, ADA. (e) This Contractor shall, at his own expense, obtain all necessary permits, fnspectlers and licenses, end empty with all local, state, and federal ordinances and the rubes end regulations of the Underwriters' Laboratories, Inc., N.F.P.A., N.E.C_, end the Local Utility Company, anything herein specified or eheuarn en the plans to the cantray netwithstad'ng. (F) All work shell empty with the regiirements of the Le dlord. (g) All fixtures, ego event, panels, etc., shall be installed no strict axorde ace with the manufacturer's inetructiens and /er reconrnendatiers and good industry standards. If there is a =filet with cedes or acvre mentiarUd reepiremente, contact the Talent's Gorotructie n Drpe'rtmeit lerrediately. (h) Should any cinemas in the plate and specificatiae be rewired to ccnrrrm to these rules or crdinmcee and regalreme tte, the Company shalt notify Tenants Gx etructian Dsportrneit before the time of submittng his bid. After the contract is auraded, the Contra -ter will be held to complete all work raceway to meet all r. lee meite without extra aspens' to the Tenant. 42. EXAMINATION OF PREMISES, FIELD MEASUREMENTS (a) Before submitting proposals Per the work, each bidder shall be held to have examined the premises and satisfied h m to the e xisting aaditioro under which he will be obliged to operate in psrfermig his part of the wank. The Contractor shall crake all field mamu+emants necesee y for his work end shall be reepaasible for their accu-acy. (b) The drawings provided one geernlly indicative of the work to be installed. Should a bidder Find die: mercies in or omission Fran the drawings or specifications, or should he be in doubt as to their marling, he should immediately notify the Terra roprxesetative. IF these instructiaas ere igrnered by the Contractor, he will be reap: risible for famishing the proper or workable equipment as neceswy. (c) Na extras will be allowed the Contractor en account of his Failure to make the above exernknatien er reelect to include all labor ad materials required to complete the work. (a) (b) (c) G3. CHASES, RECESSES, SLEEVES AND INSERTS (a) All chases and recesses for conduits in new walls as required by this Cantractor for the accommodations of this work will be provided by the Architectural Trades Contractor, but this Contractor shall be responsible far the accurate lecatien of flame. Provide all sleeves and apenlnes In walls and floors as rectai+ed. Inserts shall be of the tapered rut type with lead or non- corrosive alloy expensive retainer sleeve. Single units may be used for email work, but multi or compound plug-in unite shall be used for large work. The use of woo den plugs is net permitted. G4. EXPANSION JOINTS (a) Install aversion conduit Fittings at buildirta steel or canasta apessfen joints we shown as the drawings and/or where repaired, complete with boding jumpers. When installed in tolerate, me loop of the barring jumper shall be the mastic joint. G5. CUTTING AND PATCHING (a) All cutting and patching that may be necessary For the installation of the system specified shall be dere and repaired by the Contra-tee- under the direction and to the satisfaction of Tenant?e Construction Deportment. (b) No cuttrg of structural were ehall be done without consent of Talent's Casstructien Dspatmer t being previously obtained in each case ad all such work shall be dote in accordance with Tent's Construct/en Department's direction and under its supervlsten. G6. DAMAGE TO OTHER WORK (a) This Contractor will be held reepaneible for dermas to other work caused by his work or through neglect m this pert of his =Harm. All patchkna raparina of damaged work will be drone by the Cmtrcactor• who installed the work, as directed by Talent's Caetructien Department, but the cost of ears shall be pad by the Centmatar. G7. MANUFACTURER'S DRAWINGS (a) After the contract is awarded, this Contractor shall submit six pmts of all egrfpment and six brochures of Uehtfng fixtures to Tenant's Catstructian Department for its approval before arty equipment is purchased. (b) Approval of menufaetuw's drawings, hewever, shall cover design ally, end shall not be caretrusd as a check upon the same. Such approval shall neither relieve the Contractor from He responsibility for proper caristructien or accuracy of measurements, nor from the neccessity of furnishing the labor and materials regaled by the orfgine drawinge or epecificatiae but not shown on said menuFacturer's drawings when approved. (c) Upcn completion of the job, this Contractor shall deliver to Terri': Construction Deportment a complete set of approved manufacturer's _ _ strop drawing aril fixtu a brochures. GS. STR_ UCTURAL AND MECHANICAL DIFFIWLTIES _.._. - (a) Should ay structural or maeheafcal difficulties prevent the eettng of cabinets, renting conduits, installing outlets, etc., at points shown en the puns, or specified, the necessary minor deviation therefrom, as determined by Tenant's Canetructicn Department. will be permitted end must be made without additional cost. The Contractor shall check the location of all mutlete and egafpment with Tenant's Repr'eeectotive and the final Architectural, Mechanical and Structural Drawings against interferences with other trades, before installing soma, All discreetness shall be called to the attention of Taunt's Rsprasentativa before proceeding with the work. (a) Provide all Overlaid micelle-moue iron, supports, Framing and braes repired for the isetellation of endue, panels, Fixtures, cutlets, pullbeacae, etc. Gil. FUSES (a) (b) GI2. SYMBOLS, (a) G10. GROUNDING (a) Tralsfo rners, panels conduit systems and other egpiprnent which is a port of this installation shall be securely .eluded, bath electrically and mechaically, in accordance with the National Electrical Code, State end Local Inspection Sweats aid Power Cernery, In addition to fuses blows during construction and testing, provide a complete net of fuses for all Fuse holders in panels, switches, staters, etc. All Fuses shall be "Fusetren" as =Veered by the Busemm Mfg. Co., or low peak dual element Fusses. Fuses for use in motor branch cirtwits shall be sized far 125 4 of full load current of the motor. CIRCUITS, AND OUTLET The *merge ere intended to show the deeiee and aeergerne t of the nstaUaticn. Outlets are numbered and lettered thws: -i', 'A', "A -3', 'C ". A letter and number designates the lighting panel and circuit number, and the separate letter indicates the lighting fixture. In the case of multiple switching, a lower case letter 'a', 'b', 'c' adjacent to the switch, outlet or circuit aid which items ass controlled by that switch. (b) The watts?" of each outlet is marked en the peel echedule to canWarm to the State and Loral Code regain 'neate. The circuit numbers are included to indicate which outlets cm to be =meted to the some circuit. GI3. CHARACTER OF INSTAI.I.ATION (a) All wirng shall be conduit and in accordance with Code regirrememts. (b) All coduite in Flashed portiere of the balding shall be connected in walls, flows or ceilings. Conduits in the service portions of the buiiding may be run exposed. (a) All co-malts shall be properly eupported throughout. No horixaital arose runs of aenduite in petitions will be allowed except by special permission of Tenant's Constraactim Department. (d) All conduits stall be put up watertight, and must not we into contact with, or be fastened to gather pipes cr ducts in the building. (e) Wiring for exit lights aol emergency lights shall be in separate conduits as rewired by the N.E.C. (f) The wiring end numbering of the breach circuits shall be exactly as indicated on the drawing! and panel schedules. Each circuit shall be carncted to the lights or outlets and circuit breaker number exactly as shown. If changes are required for lcad bal •icng preen, contact Tenant's Cenetructicn Deportment. Branch circuits shall be sited as to allow not more then a tux pa-cant voltage drop from panel to extreme outlet. GI4. MATERIALS (a) All materials shalt be U.L. Approved, new and the bast of their respective hinds, shall conform to all standards or requirements gemming the sane, and shall be approved by Tenant's Construction Department before being installed. (b) Where a specific manufacturer or trade name is mentioned In the epecificatien, It is to establish a etend rd of quality. Subetitutien of other makes thet may be judged equ l by Tenant's Ce netructio Deportment may be made only by its authority in writing, and must be made prior to time of bid. (e) Tenant rescreen the right to rewire this Cahractar to summit samples of arty of all articles or materials to be used wrier thane epeciFicatkns. (d) All materials shall be in accordance with Code requirements and as follows. (d -1) Conduits: Conduits 2' and over in size, all outdoor conduits and all conduits in floor skis stall be heavy wall steel hot dipped galvanized conduit. All conduit in carted with the earth shall be heavy wall steel hot dipped galveafiaxed conduit. All other conduit, except as otherwise indicated on plans, shall be galve need thin wall or aluminum. All =duns must bear the U.L. Label. Minimum size for conduits shall be 3/4 ". Underground rue or arm n floor slabs shall be 3/4' minimum size unless otherwise shown en plan. (d -2) Wires for service peel feeders and three place power txanch wiring shall Is Type NW or THHN. All circuit Crotch wiring shell be Type THW, minimum size 112 unless otherwise specified or shown on the drawings. All wire shall bear the U.L. Label and shall be copper. All splices shall be made with insulated soldrlees type cornectare, (d -3) Receptacles! Duplaac receptacles shall be Hubbell #5362 or Arrow Hart 45735; single receptacles shall be Hubbell *5361 or Arrow Hart 05721; Isolated around duple% receptacles shall be Hubbell #IG- 5362- orange o Arrow Hart iilG- 573q - Store ngei Twist -lock receptacle shell be Hubbell ii1G -4710 an Arrow Hat SIG -4710. (d -4) Floor Bone Tire. gang - Hubbell 4184314/SH -3085 er Steel City 11843/P- 64- 3G-CP; two gong - Hubbell 1i8- 4214 /58 -30134 er Steel City ' /P- 64- 2G-CP; :mate gong - Hubbell St 414/53 -30&3 or Steel City t11341/P -64 -CP. Ali Floor boxes to have braes carpet flings. All floor baxee shall be shallow type, watertight, and semi-adjustable, (d -5) Erase Cover Plates (far Floor boxes): Duplex lift lid - Hubbell ilS -3825 or Steel City *P- 64 -PS; Plug Cover 2' and 3/4' combing i n - Hubbell *S2425 or Steel City iOP- 64- 3/4 -2. Provide other type covers as needed. (d -6) Weather Tight Sox and Receptacle: Located at rooftop HVAC egpipment shell be Hubbell #GF5352 (NEMA 3R) with a weatherproof cast ahrninaurn lift cover Hubbell #CW1°2614_ Box shall be waterproof and weather tight. (d -7) Wall switches shall be 20 amp., 120/277 volt, toggle type Engle pole - Hubbell #1221 or Arrow Hart rtlggl; double pole - Hubbell #1222 or Arnow Hat wlgg2; three -way Hubbell 41223 or Arrow Hart tilgg3; four -waay- Hubbell is1224 or Array Hort #1944• indicating with pilot � indicat li - Hubbell *1221 -PL or Arrow 1i2ggq -l. (d -8) Ceiling outlet boxes: shall be Coda gauge 4' octagonal galvanised steel with 3/8' standard fixture support secured with bolts and nuts. (d -q) Wall outlet boxes In rplastsred masonry shall be Cods gauge galvanized steel, 4' sgiarte, 2' or 2 -1/2' deep as required. Boxes in plastered or painted walls shell be galvanized 4' ewe, 1-5/8' deep with 5/8' high single or two gang cover. Outlets in armed wane shah be 'FS' or I Fp' type cardulets. 'Built -up' outlet boxes are not acceptable. (d -l0) Pull all junction boxes shall be Code gauge galvanised steel with removable ee ew -en covers with bees =ewe, and without K.O,'s which shall be cut in the field as regafrad, (d -11) Diecrxrect switches shall be heavy duty, for voltage ad of size as indicated on plans, fused or man -fused as required, single throw, externally operated, edafck -matte end e rick- br'edc, lelestingraise, I.T.E., scree P or General Electric, with interlocked covers. ELECTRICAL SFEOF (d -12) Time switch shall be CORK WOOL equipped with reserve power end seven day dial, furashed by Talent installed by the Contractor. Switch shall be equipped with the number of poles and throws voitaae and ampere rating regilred. Minimum ceded retina shall 40A. 'T' rated For tutasten tamps. (d -13) Lighting enact (if applicable-sea the electrical riser diagrern) shall be GE stCR260L 12 pole electrically held contactor furnished by Tenant, installed by this Contractor. See wiring schematic on the plans. (d -14) Manual starters shall be 2 -pole with overload protection, Allen - Bradley Bulletin 600. Staters in finished eras shall be flush mounted with Rush stainless steel plates. Starnes in unfinished areas shall be in NEMA I enclosure. Staters for 14VAC ecyipmeit to be famished and installed by Mechanical Contractor. Verify. (d -15) Magnetic starters shall be across -the line, combination fusible, or nen- combination as shown en the drawings, with NEMA type 1 coils and 3- overload relays. Combination eta -tern shall be Allen - Bradley Bulletin 701. Starters shall be as neruFactured by Allen- Eradiey, as listed above, Cleric Controller, Cutler- Flarrmer, General Electric, Scram D, Westinghouse, a- approved egxai. Check type of motor with mechanical Contractor, eo that starter will match the motor chnracteristice. Starters for HVAC erripnrasnt to be furnished end installed by Meahenical Contractor. Verify. G15. POSITION OF OUTLETS (a) All autiete shall be centered with rsgerd to beams, paneling, furring, trim, etc., and the Contractor shall consult with tenet'. Construction Department In raged to furing walls, or ceilings before ffx"nng the location of the outdate. (b) The Contractor shall check all door swings and the repaired heights of all wall outlets with Tenant's Construction Deportment prior to the installation of outlets and wall switches. (c) Any outlet which is improperly located on mead of Failure to take account of the above conditions shall be relocated at the Contractor's expense. (d) The outlets shall be located as follows ar as indicated on the plans, unless otherwise directed by the Tenant's Construction Deportment en the job: (d -1) Wall toggle switches shall be 48" to centerline of bax above floor. (d -2) Convenience cutlets end junction boxes shall be 18' to centerline of box above floor, or as indicated an plans. (d -a) Telephone outlets wed junction boxes shall where indicated on the pleas. (d -4) Thermostat (by others) shall be 48' above Hoar. (d -5) All other devices shell be located as directed In the field cr as shown on the plane. G16. TEMPORARY POWER AND LIGHTING G20. (a) Provide and maintain 120/208 volt, throe phase, 4-wire service lines n Stare Area in locations 03 repaired, as castration progreseees, including weatherproof sockets and receptacles on approximately 30' 0' centers, one for power end one for lighting. The service lines shall be sized to accommodate a 15 HP, 208 V, three phase motor in addition to the repaired lighting end receptacles for small motors. Make the necesssy amangernertts with the Landlord for temporary service ad pay all their chew's. Provide safety switch, metering, lamps and polarized grarding receptacles. Cherges for electric energy cenairned will be paid by the Architectural Trades Contractor, GI7. DRY TYPE TRANSFORMER -_ ____ ._._.__...____ ___.__..__._. (b) (a) Pry type traefermer to be size as indicated, 480 volts, 3 phase, Primary, 208/120 volts, 3 phase, Secondary, ad have six i -1/24 taps, 2 above and 4 below rated prime y voltage, class 14 insulation, 45 db minimum earl level. Transformer to be UL listed under the regyirenente of Staded 506 end meat the requirements of ANSI C8q.2 end NEMA ST -20. Unit to be enlaced in drip proof metal enclosure with natural draft ventilation. Core and coil aeeernbly to be mated en rubber isolation pads to reduce noise. Transferrer to be floor mounted. transformer shall be similar to Westinghouse Electric Type DT-3, or approved .cal by General Electric a- Severe D. F.P.E. is not as acceptable manufacturer. tratsfor mer grounding shall be in accarda cs with National Electric Code regpireneits. GIS. LIGHTING AND POWER PANELS (b) (a) Lighting pawls shall be of pare board caastructien, factory assembled, with main breaker or men lugs only, on indicated on the plan, designed for 120/208 volt, 3 phase, 4 win, or 277/480 volt, 3 phase, 4 wire syetens ce ehcnun an the plans, Branch circuit breakers shall be positive make and quick break, thermal magnetic, trip free end of sites ad number of poles as indicated on the plan. Branch breakers shell be bolt -en type, Weetighnuse '13A13' or 'Gl. 6 series, or equivalent if higher interrupting cr>paities are roc aired. Panels shall be Besting -are 'Pow -R- Liras I' for 120/205 volts and 'Paw -R -Line 2' for 277/480 volts. Paula, main breakers and branch breakers shall be of interrupting caprities as required by the utility company, landlord and drawings. Pascua, main breakers, aid brunch breakers shell be of the some manufacturer. Egpipment equivalent to the above as manufactured by Gerard Electric, Same D or Siernee -ITE ere acceptable, provided =taloa cuts are submitted prior to bids. Na other mawFacturrs will be coneldered. Cobrete shall be of Code gauge steel, with flush hinged door aid flush lack and key. Breakers feedin lighting circuits shall start at the top of the panel, end those feeding receptacle, motor ad other loads shall start at the battam of the peel. Two end three pole breakers shall be common trip type. Breakers Feeding motor circuits, night light, emergency lights, exit lights, time switch circuits, etc., shall be egplpped with locking devices. (e) Provide in each penal a feat typewritten cord, in card holder, identifying the _ penal and each esrruit, • irnmediately uPat_ccrnple ion of the_wiri - �.... Glq. LIGHT AND POWER FEARS AND BRANCH WIRING (a) From the respective fuss and breaker branches of the switch -rack ad lighting panels, furnish ad istall feeders as indicated on the wiring diagram on the plan. (b) Conductor size shall be as dictated by the circuit length to recant aid allow for voltage drop. (b) (c) (d) MATT-HOUR/DEMAND METER x r •'4�txri 01 �a1 it ';:il c2 aerbir i i td ettah v' /love ' ,eaa f r ah •fhra a-T.- ea:raj, (Mater is eat ; vcy;irod if Dior: r =Fey F ey cam ny rr, min ,a: ;' anevid i as,) That :;mi :ter shall else fc.m!ck thva approcrlas ,Meter be D type f:s' 4 w fr Volts Clete 120 100 LW 2i:9 (4111) 240 200 (480477 e Mop no l5 f, rare asnitera :i:t: rr-Ftf:rtir tapw,the ry -• ail t , • 4 Norieu with ,u Tree M-Faa d-rzel tame , 3 eteser pr r kA4 taanceva iritaaai i'iatialie' fir "'sif •mica f aer bar ill la ll 3rd lay la i 44 701ei5G54 30 , I44 :00(ti.:: -Data (c) Meter end socket shall meet the regapremients of local utility company and/or Landlord. CATIO S G21. ELECTRICAL WORK (a) The Mechmice Contractor and/or his supplier shall furnish and install all starters, push button stations, relays end control wiring pertinent to the operation of the WAG eeripnenat. The Electrical Contractor shall furnish ad install all power wiring end disconnect switches. The Mechanical Contractor shall at the time of ordering his eq ipnes t, also provide the Electrical Contractor with copies of the necessary diagrams for his use. (b) The Electrical Contractor shell provide only miseelleieous starters, relays aid disconnects thet may be required for the rating grille, sign toilet exhaust Fan, etc. All motors 1/3 HP and small shall be single phone, 1/2 HP aid larger shall be three phase except cs otherwise specified. Thermal overload protector for all motors shall be provided. Nagnetic starters shall be provided for all three phase motors. Thermal overload relays shall be sized Fcr 1254 of full load motor current. Switch and fuse units will not be acceptable unless specifically indicated. The installation of all rooters, starters, end other electrical work shall conform with the N.E.C. All electrical equipment such an starters, panels, discerned switches, etc. shall be permanently labeled using engraved bdcel'ite name plates. (a) (d) G22. EMIT AND EMERGENCY LIGHTS (a) Exit lights and emergency lights shall have self - contained battery unite and shall be connected to the emergency system oe called for on the drawirge, and in strict aecardauce with the local, state and rational bulldog Codes, using separate conduits foam other systems. Exit end emergency light units shall be furnished by Tenant end installed by this Cotractor, except as rated en the pins, or when local cedes and/or. the Landlord have special requirements. Caardbiteta with Tenmt?s Carnstructien Deportment. All exit lights (except pendent mounted) shall be mounted with the bottom of the light flush with the top of the door don. Verify heights end locations with Tenant's Construction Department. G23. LIGHTING FIXTURES, LAMPS AND BALLASTS (b) (a) (a) (b) G24. SIGNAL SYSTEM (a) (b) (a) G25. AUDIO OR AUDIONISUAL SYSTEM (a) Audio or AudioN'suol system shall be furnished end iistalfed by Talent's Audio/Visual Unsuited. G26. SECURITY SYTEM/ANTI -THEFT SYSTFJI (a) If a drywall ceiling is to be installed in the Sales Area, this Contractor shell run empty conduit according to schematic disgram sheet 'E -3'. d4riilc, (if r sir alp), will be erettrellei by a le,V, stttiai(a) puss i,uttoa e -amen ord Bate rig in , ail to Fua'rtiote5 bye tanw IRvli t'se Geilie rnertufeettree trod ear tea by this Cattecocaea. This Cam tv ix^rsvpda ;Men -fun epee:mvCt vanish. Feel d jatrrre nt of the limit cr.aitehs eE -il la® ors by this C utr iir ',a, the flearea e the eterekent la ceneste. G28. PAINTING (a) All required printing and touch -up of lighting fixture., pendants, brackets, conduit, plates, ecpipinent, etc., shall be accomplished by the painters employed by the Architectural Trades Contractor at the mcpanse of this Contractor. Cooperation between the trades In this matter is essential to provide a satisfactory installation. Certain lighting factures, detailed in the Finish Schedule, require painting or touch -up at the site. (Verify with Tenant's Construction Coordinator the fixture ' types' end finishes). The Contractor shell a rage for and supply these fixtures to the Architectural Trades painter at a mutually eatiefectey time, prior to the installation, This Carrtraeter shall mat rel'reuish antral of these lightng Rearm and shall retain responsibility for their safety and function ability. Refer to the Supplemental Electrical Trades Speciflcatfon, drawings and Finish Schedule for light fixtures, light track, etc., which rewires painting of 'touch -up'. All cetera- ceduits, Fittings, cabinets, bass etc., shall be printed two coats of lead and oil paint of color as directed. Electrical egtepmeit in prime coat finish shall be painted two coats of teed ad all print of color as directed. Repaint or touch-up factory panted egpiement damaged during shipping or prior to Final acceptance, to match the original factory Finish. Before panting, all surfaces shall be tha-oughly cleaned free fran runt, dl, caned, plaster or other foreign material. Nameplates of egaiprnent shall not be printed. Do not paint the interior (reflective surfaces) of light Fixtures. (b) (a) (d) (a) (f) G2q. TESTING (a) Oh completion of the work, the nstallaua, shell be entirely free from grounds aid short circuits. All circuits shall be tested and ticketed. All motor circuits, control circuits, signal systems, interlocking and electric heat circuits shall be tested for proper operation. GEO. AS -BUILT DRAWINGS (a) Within 20 days of completion of the job, this Cartrecter shall male en a set of contract prints all the charges made during centruetian due to Field conditions, Addenda, Bulletins, field crass, etc. Sane shall be delivered to Tenant's Construction Department prior to final payment. G31_ GUARANTEE Refer to plans for lighting factures, if my, furnished by this Contractor, All lighting fixtures shown on plane shall be installed by this Contractor. Iretailaticn of the lighting Features shall be in accordance with the manufacturer's ree}aire nente. All factures shall bear the Underwriters label. Same fixtures end light track require wirng and/or assembly in the field. This work shall be performed by this Contractor, at no additional cast. Contact Tenant's Caustructien Department prior to bidding for further information. Recessed fixtures shell have suFFfcent 'tail' for removal. Support with hanger wires and/or bon hangers as ntegrired by code end as required to prevent Bagging of ceiling. All tncedencent lamps shell be furnished by Tenant end installed by this Contractor. l9ucreeceat tubes shall be furnished by taunt and installed by this Contractor. Bellaste shall be included with the light Futures aid shall be C13M, ETL and U.L. approved and of the HPF type, Class P, Energy Saving Type. They shall be eared rated 'A'. Surface- Mounted Fluorescent Fixture nstallatian shall =fern to N.E.G. Section 410.76. Check architectural plans For ceiling types. All ballasts For Fluorescent Factures shall be integrally Fused, when regpired. The finished floor to fixture mounting heights one given to the batten of the fixture ad must be maintained. The Electrical Contractor must cut all pendants provided (IF reapfred) in order to do so. On remodeling projects, all Features (new, existing, and raised), shall be ralanpe l with the lamps (furnished by Tenant) indicated can the 'Fixture Schedule'. All old lamps shall became the property of this Contractor and shall be removed Pram the site. The lanes in the storefront sign shall also be replaced. All existine light factures and light tract not reused (except fluorescent strips) stall be carefully renamed, pocked, end reamed to Teurnt. Instill a low voltage eigual bell system (Fumlehed by tenant) with bell in location m inndicated on plan, This Contractor to provide all wiring in conduit, outlet boxes, etc. Tenant to furnish bell, button end tre nfe rner. Hell shall be mounted above cell's?. Push button shall be flush type, mounted 4' 0" above the floor. (a) The Contractor shall give the Owe a written guaaitee that he will make good, at his awn expense, any defects in materials or uaerkmenship which may develop in one yea- from the final acceptance of the work. SUPPLEMENT ELECTRdCAL TRADES SP ECIFICATION_ NOTE: The Eleetrieml Trades Specification is divided into two ports: I. SUPPLEMENTAL. ELECTRICAL TRADES SPECIFICATION defking the scope oaf work end the special requirements and materials far this project. II. GENERAL ELECTRICAL TRADES SPECIFICATION dsfknng stadord recyrireme+ts aid maGnrfals, If the General Electrical Specification is not attaalyd, c ntect Trait iiiwlediately, In the event that conflict exists between the General Electrical Spscifkations end the Supplemental Electrical Speclficatfos, the Supplemental shall trice precedence. 51. BID BREAKDOWN (a) This Cordios; ter shall indicate as a separate item in Hs bid the cast of materal and labor for the installation of !marring service wirng, meters, discamects, switch gear, transformers, panel boards, etc. This portion mf the bid shall be indicated as "Electrical Service". (b) All materiel ad lobo for the nstallationn of broach circuits, lighting, HVA1C egripment, etc. shall be listed separately as "Branch Wiring" 52. DRAWING{ (a) The Electrical Drowngs, the Electrical Symbol Sheet, the General Electrical Treacles Specification, the Architectural and Mechanical plans aid specifications fern a part of this specification. 53. SCOPE OF WORRK (a) 54. TELEPHONE SYSTEM (a) Contractor to coordinate with the Landlord the installation of conduit system to the telephone backboard location as shown on the drawings. Installation of all telephone *Owned to meet reaJirerneltes of this specification, Landlord regpire- rnarnts, end the regilreneats of the Telephone Company. 55. SYSTEM CURRENT CHARACTERISTICS (a) cx� ne . isxs Saralee far the epee Is _. _Yale, C' s 012515, fair wire, to he retteeeted trs locret-iccn eaewrn, (b) Bair air? erste, fi zrnafcamsrs di:menet ewitehea etc, may 'l reruwed if zi good cvrxlitior end cf proper eke, capacity, acts. Non,i Mow or c:seul FM warmed is rot on exeateas rearefetarear 57. SERVICE CA'NECTION (a) (b) Errs. n t 'icu f'O• the opus- !:5 J _. vrdlk, three pi`.carm, facer wire, locatea tee e'SC,r.Cn. (ii) This C•mteavtor E cit4 wrscloetort cold ea nevit faaar, tie Lardicrd'ns dis'trilaution r ;i wont or mean to the %cake peels, fa thin sere a ahem m the a{r¢glal e. Sq. EXISTING CONDITIONS (a) (b) (a) The scope of work shall kclude, but not be limited to, the following aeons and miiseellaucus work. (a-1) ketalliatian /relocaticn/modification of all electrical distribution, lighting and miecellaraeous equiprnsnt detailed en the electrical drawings, er rewired to provide a eampleste ad operative installation. (a-2) Installation and/or modification of telephone distribution agriprnent. (a-3) Installation of sect ity /anti -theft raceway system, where had teeing is to be installed. (o--4) If ravened by Landlord or local building cedes, iistaliation of a file end awake detection system. (o-5) Cocraiinatfan or all work with Landlord, other entractes, Utility Company, a'd a'ly �y having jurisdiction over cry area of the installation. (�.. t a ib E . 11 i� ,les:t his( €). (' rn5 M set (u). n to atecttr,u teat isetise ri) Incoming Service Ircendescent Lighting Fluorescent Lighting Receptacles end Miscellaneous HVAC 277/480 volt, 3 phase,4 wire 120 volt, single phase 120 volt, single phase 120 volt, single phase 277 volt, single phase __--. Y6At, _.._. _ pf uMV■ vcit _ .__...,.... pieaa The Electrical Service for the space is 277/480 volt, three per, four wire, located as sham. The Cartreder shall extend conductors from the Landlord's distribution weep-nest through the existing conduit to the service peels for this space as than an the drawing. This project is being installed in a previously aacupfed space. Demolition for this space has been covered, in general, under sweats specification. This work shall include my incidental demolition rewired to provide a firet-class project. Certain electrical equipment (lighting fixtures, outlets, service egpipnerat, etc.) shall be relocated ad/or reused as indicated on the plans. This Contractor shall verify the condition of such adyfprelent and include in his base bid a price far replacing each egaipraent not deemed adequate by Thereat Repre en- tertive. It stall be the responsibility of this Cantrecter to infirm Tere nt of egafpnent In euestianable condition. � j i i LTHIT HEATER iti: Ri:IF F.C. +ahrif irate' 11 .a well runuraW electric ERn r h=, aae with ii time capeety axr 75 ale. The 46{nct at ell be eace'e e I8 evaate ea fated mil. Ma et hc;s". tea eliteie be aavplata oirlr s�lr. rrwua�f lest and o {u able easlares 1 e, Ail *metes macs of the as ire, shill Ina phosphate weed to rrsu`at etereulan. The unit 'aster shall ha,a area tareteh digs tte e P'Fti2neta l t *etc ,Al€ tau vellego areeta?rs FCC f be provided with the mit heater. Preadu o dicarract at the it amens: Unit evil be wired [ _ , _ .Volt - .Fhase, 60 hierte e r^ati,n. ±tif rebel ant t Ali bs ptr tr `t mr air relaireneents. _sit iteaa shall be rnadsi MU-H-07 az r takasta -eaa by anmzr r apreeeftel ea:a ETt hd"sL.t. h4E;a,T F .C. ehel ire,ail a reassed electric well haste ,,`h iaeot. iaa capeety cf 1.8 KN. The eabirrst eheli lea made of Zi gogiso allvcram d 0,,4 sl. The wail l yr shall hays e scan faf ra oiuml Pm-ens with c trawl g rille. Fhm wail hrdar shall bs camp:l c 'wit.h polo lifotf a tubricatd r. s a disconnoct =wretch, avernet elm, end Peered sheathed heating element. All centres shall is laical to than well heater. Keil her &ell be wired Fen' ._._..t=wit, __-phees, 60 hertz ceacretler. All Inetaliatiaua shall be per unit mariefeettec reopiramente. Tina Wall heeler einal? be noel A34II- 4rk.:: nuaauf a tivnsd by C rmsrh or reap-: -1 oboe. 512. SERVICE ECUIPMENT (a) All .?aliment shall be installed in strict accordance with the mcnufacterers' isstnetans and/or' recarineadations, and good industry etandards. If there is a conflict, contact Tenet's representative immediately. 913. FIRE AND SMCICE DETECTION SYSTEM (a) IF rewired by the Landlord or local building codes, this Contractor shall cooperate with the M.C. to furnish aid iretall a fire end smoke detection system, lncludirg but not limited to, snake detectors, smoke exhaust fens, visual aid audible alarms, tamper end flow switches, etc. All equipment must be fully operable and meet Landlord aid local bulldirng code re:grenente. Contact the Tenant's representative with my dlecrepaacias or mleundarstadfngs. SI ned D005D RECEIVED CITY OF TUKWILA FEB 0 4 20013 PERMIT CENTER il estfieid' ,,__,,-,,,.. Working Drawing,,, i. A pproved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- : tube kept on the job site at all times. 1 /3/08 Date 0 1-104T 215 5' -O" A.F.F. STOCKROOM NO CEILING 11' -0" A.F.F. IIF 104a2 W - i - r - r - - r- r-- r- m` n - r- E E r- E --- - --r ._ Er - � Z.i _Er -r"r r - F vi ! i f 1 i f l P i I E E - E E I_r I -- -r.. 1-- �..f._�_Er - -E r - `_E C-nrEf I- 11A1 IIF Sa -4 Sa -4 Sa -4 1 TOILET ROOM 7A 7E 7A 5a -4 Sa -4 EM -I CO • � =1 PASSAGE 11' -0" A.F.F. "aerie" NEW FIXTURE SCHEDULE NOTE: ALL LAMPS FURNIS1 -1 BY TENANT TYPE DESCRIPTION FURN. BY MOUNTING LAMP FIXTURE QTY. WATTS Ta- TRACK LIGHTOLIER SINGLE - CIRCUIT TRACK TENANT SURFACE SEE "aerie" ELECTRICAL SINGLE CIRCUIT TRACK SYSTEM FIXTURE SCHEDULE TRACK HEAD JANMAR SERIES 740E CMH 141-1T Ha - TENANT TRACK MH W (1) G 99 74.5 G5.5 PAR20 44 (MERCHANDISE DISPLAY LIGHT) H°2 D TRACK HEAD JANMAR SERIES 740E CMH WHt (MERCHANDISE DISPLAY LIGHT) TENANT TRACK (1) CI"Ihl 3%4 T4.5 G8.5 PAR20 44 ENE GRAPHIC DISPLAY SYSTEM (NON - ELECTRICAL) �- SEE SHEET 'A.0.2' FOR MORE INFORMATION TENANT SURFACE N/A CUSTOM 12" PENDANT MOUNTED FIXTURE WITH TENANT PENDANT (2) OSRAM CFIBDD/827 36 e � 15 "x19 ". FABRIC SHADE (SALES AREA) C USTOM PRINTED 30" DIAMETER FABRIC SHADE e (FITTING, R OOM VESTIBULE) TENANT PENDANT (2) OSRAM CFIBDD/827 36 7.B.D .� TENANT PENDANT (2) OSRAM CFIBDD/627 36 RUSTIC GLASS PENDANT TENANT PENDANT (I) PHILIPS 30.20 /LL 120V 50 (SOLD BY POTTERY BARN - ITEM# 679355B) A 6' -10" A.F.F COVE CE (SALES)/ FLUORESCENT STRIP -4 FT, ONE LAMP, RAPID TENANT a (1) GE F32T8 /5PX30 30 START, LIGHTOLIER #5N140R5HPFI20 50 12 A.F.F. (StocKRlJ0M) 8 FLUOR. STRIP -6 PT, TANDEM, TWO LAMP, RAPID TENANT CHAIN HUNG (2) GE P32T5 /SpX30 61 START, LIGHTOLIER #5N142RSHPF120 50 12' -0" A.F.F. SEAMLE55LINE T6 FLUORESCENT 3.4" TENANT RECESSED (1) FRt850- (3500K) 27 ' Se-34 ▪ ' HIPPO SAL- UW550A ▪ SEAMLESSLINE T6 FLUORESCENT 40" TENANT RECESSED (1) FRTI000- (3500K) 30 5a -40 HIPPO #SAL- UWI000A VESTIBULE O -6" A.F.F. ISA 13A NOTE: ALL MOUNTING HEIGHTS ARE TO LOWEST POINT ON FIXTURE SCONCE FIXTURES ARE TO CENTERLINE OF MOUNTING BOX 15A Sa -4 "aerie" NEW FIXTURE SCHEDULE NOTE: ALL LAMPS FURNISHED BY TENANT • - - -- SEAMLESSLINE T6 FLUORESCENT 50" TENANT RECESSED (1) FRTI250- (3500K) 30 941-50 HIPPO #SAL- UWI25OA -...• SEAMLE55LINE T6 FLUORESCENT 60" TENANT RECESSED (1) FRTI500- (3500K) 46 x+ HIPPO *SAL- UWI500A LIGHTOLIE. OPEN DOWNLIGHTS ® VERTICAL TRIPLE TUBE DOWNLIGHTS #8022CCDW TENANT RECESSED (1) GE F26 DBX/830 /4P 26 RECESSED MR -16 ADJ. ACCENT. LIGHTOLIER LYtEPOINt5 TENANT RECESSED (1) 05RAM 37MRI6 /IR/FL40 /C) 37 404CLX( TRIM )- 7550FD(LENS)- 402MRX(HOUSING) CUSTOM WALL SCONCE WITH DECORATIVE FABRIC WALL 1 Ha SHADE a FITTING ROOM MIRROR TENANT 7' -0 %" A.F.F. (1) GE BIAX FLE /AI5 /827 20 � Wa2 CUSTOM METAL f GLASS WALL SCONCE @ T�I ANT WALL 1 3'-2 " (1) GE T -10 FROST 25 STOREFRONT A.F.F. CUSTOM WALL SCONCE WITH DECORATIVE FABRIC WALL 5' -B" Was SHADE 1 PASSAGE TENANT A.F.F. (I) GE BIAX FLE /AI5/827 20 REST ROOM LIGHT FIXTURE PROGRESS TENANT WALL 1 7' -0" (2) GE 60A - 52 WMP /99 60 #3015 -30 A.F.F. p 't7 SEST RI , -1 EMERGENCY LIGHT TENANT CEILING 11 EM -20 SURE -CITES #P4C -72 EMERGENCY LIGHT TENANT RECESSED (2) 10 XAI EXIT ' LIGHT EXXTEU2RWEM TENANT WALL (1) I5W GE 15T6 30 EXIT LIGHT - L.E.D. LITHONIA WALL OR ® #LRPIRC 120277 ELN TENANT CEILING 2 xc ® EXIT LIGHT - LITI -IONIA TENANT ' WALL (I) 15W G!~ 1576 30 LGNSW3REL 120/277 , EDGE I y j - .__-- ._.____.__ _L5A__.__�___�5A_____.__.__._ 159i 154 Y � 2$ r - i :7A nom .__._.__ ._._ _.._ .. 1 I I i 1 5A 1 ! 5 • 01121 I.�. T � 1 .__ .... .__..1 ,�. 'l =art!• - - -.. ____.. f G►i a� I kI. .___.__._.._ -. a. 25 i i , __ _. _._. ----- - -.__. _ .___ ...___�( ►�Ik }-- .-- .. ! ■ 1 15'x, 15 ± _ 1"a ___ ___ ._A_ ____ _.w__ _ __ _ _ W� ! I Era � � _ _ w >� - �- �� -�- µ �� _ . _ . ___ _ .._ 735 TO- , - 5 M .� }_._ __ . _ 23 �- c ; 17a� -1 LIGHTOLIER POWER TRIP CURRENT LIMITING DEVICE LOL ITEM #CLD1440WH. (TYP ALL LOCATIONS SHOWN). / KEY NOTES: V ELECTRICAL REFLECTED CEILING PLAN "aerie" NEW ELECTRICAL SINGLE CIRCUIT TRACK FIXTURE KEY TRACK NO. NO. OF SPOTS TRACK SIZE COLOR Ta -I 2 2' -O" WHITE Ta -2 6 8' -O" WHITE Ta -3 0 2' -O" WHITE X ® LOW VOLTAGE OVERRIDE SWITCH FOR STOCK AREA LIGHTING CHANNEL "E ". d J -BOX MTD. ABOVE CLG. FOR WATER I -1TR. 0 LOW VOLTAGE OVERRIDE SWITCH FOR FITTING AREA LIGHTING CHANNEL "F ". Ta - I'IgA • REST ROOM EXHAUST FAN 120V, Ids, BY M.C. Q LINE VOLTAGE SNITCH MTD. 50" ABOVE CONCRETE SLAB TO CENTERLINE OF 50X (TIP UNLESS OTHERWISE NOTED). O NOTE: ALL EMERGENCY LIGHTING SI -IALL BE WIRED "RIOT" UN- SWITCHED. LIGNTOLIER POWER EXTENSION CONNECTOR (TYP). — LIGHTOLIER POWER INLET CONNECTOR (TYP). Ta -I jqq Ta -1 jqq t To jqq WcL4 Ta —I 255 11' -0" A.F.F. SALES AREA FEB 2 9 2003 REGISTERED ARCHITECT KENNLTH L BUTTS STATE OF WASHINGTON 0_ 1 LU u-L Lu Lu 1- 1 LL 1WAONddld (1 1 NO4 OAFISST -AN WF1 -97 -7 KEY NOTES: S L n 10 ----- 265 - T III 10 TO SIGNAL BELL AND TRANSFORMER NEAR CASH * WRAP 1-IC. TOILET ROOM SEE DRAWING 1 E.0 .1' FOR REST ROOM ELECTRICAL LAYOUT STOCKROOM NEW VAV BOX, 2 TN, WI TH 30/3 NEMA I DISCONNECT SWITCH. LA -3B LA- 42(IG) LA -40 TO PUSH - HUTTON AT REAR SERVICE DOOR SIGNAL BELL AND TRANSFORMER MTD. ABOVE CEILING, NOTE: SEE CASH AND WRAP LAYOUT ON SHEET 'F.2.2' FOR MORE INFORMATION QUAD RECEPTACLE MTD. I I6" ABOVE CEILING TO CENTERLINE OF BOX AT REAR OF BULKHEAD. N1/4 16 ' PUSH - BUTTON EXIT CORRIDOR VESTIBULE m rn E.C. SHALL INSTALL DUPLEX RECEPT. C 7' -3" ABOVE CONCRETE SLAB TO CENTERLINE OF BOX (CENTERED ON PLYWOOD BACKBOARD) FOR AUDIO /VISUAL CONSULTANT USE SEE DETAIL A/E.0 PHONE OUTLET * DATA OUTLET BY E.C. SEE DETAIL A /E.0.2 FOR MOUNTING LOCATIONS. 0 (2) DUPLEX RECEPT. SEE DET. A/E FOR MOUNTING LOCATIONS. 0 E.G. SHALL INSTALL DOUBLE DUPLEX RECEPT. FOR ALARM PANEL 36" ABOVE CONCRETE SLAB TO CENTERLINE OF 80X 0 24'x24 "x3/4" PLYWOOD BACKBOARD FOR TELEPHONE SERVICE. ELECTRICAL DISTRIBUTION EQUIPMENT. SEE RISER DIAGRAM FOR DETAILS. 0 E .C. SHALL INSTALL A DUPLEX RECEPTACLE FOR PAGING SYSTEM CONTROL PANEL I 5' ABOVE CONCRETE SLAB TO CENTERLINE OF BOX. O DUPLEX RECEPTACLE MOUNTED HORIZONTALLY ON WALL S' -0' ABOVE CONCRETE SLAB TO CENTERLINE OF BOX. 0 DUPLEX RECEPTACLE MOUNTED HORIZONTALLY ON WALL 6" DOWN FROM CEILING OR BOTTOM OF BEAM IF APPLICABLE TO CENTERLINE OF BOX. (TYPICAL UNLESS OTHERWISE NOTED). IO DUPLEX RECEPTACLE MOUNTED HORIZONTALLY ON WALL 18" ABOVE CONCRETE SLAB TO CENTERLINE OF BOX. FITTING ROOMS 101-40 E.C. SHALL INSTALL DUPLEX RECEPT. C 7' -3" ABOVE CONCRETE SLAB FOR A/V EQUIP. OUTLINE OF PLYWOOD BACKER BOARD BY G.C. 6' -0" AFF COMPUTER CABINET FURN. BY TENANT INST. BY G.C. DUPLEX RECEPT. HY E.C. TYP. 23' -2" SCALE: 1/2" a I' -0' PASSAGE OF COMPUTER CABINET COMPUTER CABINET SC.QPE: FURNISH AND INSTALL ALL MATERIALS TO PROVIDE ELECTRICAL SERVICE TO DUPLEX RECEPTACLES FOR COMPUTER AT THE LOCATION SHOWN ON THE DRAWINGS, INCLUDING ALL WIRING TO PANEL BOARD TO MAKE SYSTEM OPERATIONAL. FURNISH AND INSTALL CONDUIT, BOXES AND CABLE (FURN. BY TENANT) FOR PHONE AND DATA RECEPTACLES. 3 /4" CONDUIT RUN BACK TO PANEL BOARDS W/ PHONE * DATA WIRES DATA OUTLET BOX SY E.C PHONE OUTLET BOX AND R...1 -11 PHONE JACK BY E.C. DUPLEX RECEPTACLE MTD. I8" ABOVE CONCRETE SLAB TO CENTERLINE OF BOX (TYPICAL UNLESS OTHERWISE NOTED) E.0.2 PLYWOOD 0 `� 0 ' J Q e ` WOOD FLOORING SUBFLOOR Q Q ' 4i V 4 Q DEVICE SCHEMATIC DETAIL SCALE: I" = 1' -0" AUDIO POWER WIRES PHONE WIRES WIRES DATA WIRES BY E.C. 1 BY E.C. 2' -0" 107' -6 ELECTRICAL FLOOR PLAN SCALE: 1/4" = I' -0" I CONDUIT (TYP) 2 -GANG J -BOX (TYP) I METAL STUD (TYP) 1 t (6) I/2' CONDUITS DOWN WALL AND BETWEEN SLEEPERS STUBBED UP UNDER CASH AND WRAP (TYP) 92' -10 SEE DEVICE SCHEMATIC DETAIL 8 /E.0.2 FOR MORE INFORMATION (I) CAT 5 CABLE (IF REQ'D) LABEL ENDS 'OFFICE DATA" (I) CAT 5 CABLE (IF REQ' LABEL ENDS "OFFICE VOICE" r 7 1 ! OFFICE (I REO'D) L RJ -11 PHONE JACK BY DATA CONSULTANT FOR OFFICE PHONE (IF REQ'D) NOT TO SCALE PHONE PANEL 30' -0" STOCKROOM DUPLEX RECEPTACLE MOUNTED IN SIDE OF PREFAB. CABINET PANEL, BEHIND VALANCE. I5P CABINET _ r (I) CAT 5 CABLE LABEL ENDS "ISP VOICE" (I) CAT 5 CABLE LABEL ENDS "ISP DATA RJ -11 PHONE JACK BY DATA CONSULTANT FOR ISP COMPUTER VOICE /DATA CABLE SCHEMATIC NOTE: SEE DET. A/E FOR FITTING ROOM CALL BUTTON WIRING CAT 5 CABLE, LABEL ENDS "SHOPPER TRAK" CAT 5 CABLE, LABEL ENDS "CAW VOICE" CAT 5 CABLE LABEL ENDS 'CM DATA' GAT 5 GABLE, LAtEL EI'V "IP P1101t° CC 5 cAuLa uzip.L LABjLJ "caw 1 ATA _ C AUXI LI ARY 1 CAT 5 CABLE (I REQ'P , LABEL ENDS "CAW VOICE" I CASH t WRAP I I COUNTER I L (IF REQ'D) _..) RJ -II PHONE JACK BY DATA CONSULTANT FOR MAIN VOICE LINE (SEE SHEET 'F -2') 22' -108" > E.G. SHALL INSTALL ANTI -THEFT EQUIPMENT CONDUIT LOOP W/ PULL STRING, UNDER TENANT FLOOR. FURN. SY ANTI - THEFT CONSULTANT. SEE SHEET A -5 FOR DETAILS. SALES AREA 08 CASH 4 WRAF REAR COUNTER DUPLEX RECEPTACLE(MOUNTED HORIZONTALLY 6' ABOVE PLATFORM) (TYP OF 2). DUPLEX RECEPTACLE IN CEILING CENTERED BETWEEN DISPLAY GRID AND LIGHT TRACK. (TYP OF 2). i CASH it WRAP FRONT COUNTER RJ -II PHONE JACK BY DATA CONSULTANT FOR 7 5NAP/ VERIPHONE (SEE SHEET 'F -2') m E.G. SHALL LEAVE 20 -0" WIRE W AT EACH ENTRY ABOVE CEILING FOR HOOK -UP BY OTHERS f RECEIVEC CITY OF TUKV,ILA , Lu l.li l .ii PERMIT CENTER NOTE: E.C. SHALL INSTALL PLENUM RATED TELEPHONE /DATA CAT 5 CABLE, AND LAME ENDS AS INDICATED, FURN. BY TENANT. E.C. SHALL LEAVE SUFFICIENT WHIP AT LOCATIONS FOR FINAL HOOK -UP BY OTHERS. SEE VOICE/DATA CABLE SCHEMATIC AA/E.O.2 FOR MORE INFORMATION. Wsi/ki Worki Ora wing et / Approved / AivO Approved as Noted ` .r ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of thls landlord stamped set of drawings is requira to be kept on the job site at all times. 1 /3/08 ed Date Ea O N O PANEL "LA" 120/205, 30, �4w 150A M.C.B. DESCRIPTION RE LAY CHANNEL T.5 4 R LOCK HKR NO. HKR SIZE AMP PHASE BKR SIZE AMP BKR. NO. T.5 LOCK RELAY CHANNEL DESCRIPTION A 13 G EM 4 NIGHT LIGHTS L 1 20 20 2 L PAGING SYSTEM 0 STOREFRONT LIGHTING C 3 20 20 4 L AUDIO SYSTEM GOO ° SIGN LIGHTING C 5 5 20 GOO 20 6 L 8764 COMPUTER STATION 60,0 STOCK AREA LIGHTING A,E 20 7 20 20 8 20 5 SPARE C DISPLAY WINDOW RECEP. ; TOILET ROOM LIGHTING q L q 20 20 10 20 10 L SALES AREA RECEPTACLE mo FITTING AREA LIGHTING A,F 20 11 20 20 12 20 12 L SALES AREA RECEPTACLE 1 SALES AREA LIGHTING A 20 13 20 20 14 20 14 L WATER HEATER r SALES AREA LIGHTING A 20 15 20 20 16 20 16 L SECURITY RECEPTACLE 4 SALES AREA TRACK LIGHTING A 20 17 20 20 11 20 18 L. ALARM RECEPTACLE SALES AREA TRACK LIGHTING A 20 101 20 1g 20 20 20 20 L STOCK AREA RECEPTACLE SALES AREA TRACK LIGHTING B 20 21 20 1W 22 20 22 $ SEASONAL RECEPTACLES SALES AREA TRACK LIGHTING B 20 .-23 20 20 1 20 24 B SEASONAL RECEPTACLES 10051 SALES AREA TRACK LIGHTING $ 275019 VA/(480x1 732) 0 53.2 FLA 53 FLAx1.25 = 41.5 MIN. CIR. AMPS 25 20 11 20 26 $ SEASONAL RECEPTACLES 27 20 20 28 201 20 20 30 31 20 20 32 SPARE 33 20 20 34 L RELAY PANEL POWER 400 SPARE 35 20 20 36 L DIG SYSTEM POWER 157$ SPARE 37 20 20 38 L CASH 4 WRAP RECEPTACLE 540 SPARE 3q 2 20 40 L CASH 4 WRAP ELECTRICAL 720 SPARE 41 20 20 42 L CASH REGISTERS 1440 8610 8096 01645 26351 VA/(208x1.732) = 73.2 FLA 75.2 FLAx1.25 = 91.5 MIN. CIR. AMPS 26351 PANEL III I 277/480, 3O, 4w f''I 100A M.C.B. DESCRIPTION RELAY HNN CAEL T.S LOCK NO. BKR SIZE AMP PHASE HKR SIZE AMP NbR T.5 oR LOCK RELAY CHANNEL DESCRIPTION A B C FPVAV -1 L I 20 7 0 5 2 L 45KVA TRANSFORMER 3 20 4 8764 5 20 6 8764 7 20 20 8 SPARE q 20 20 10 SPARE 11 20 20 12 SPARE 13 20 20 14 15 20 20 16 17 20 20 15 1q 20 20 20 21 20 20 22 23 20 20 24 10051 8784 3734 275019 VA/(480x1 732) 0 53.2 FLA 53 FLAx1.25 = 41.5 MIN. CIR. AMPS 27599 GENERAL ELECTRICAL NOTES 1. PROVIDE LOCKOUT BREAKERS AS INDICATED ON THE PANEL SCHEDULE. 2. COVER PLATES FOR ALL RECEPTACLES AND SWITCHES TO BE WHITE PLASTIC TYPE. RECEPTACLES AND SWITCHES 51-1ALL BE WHITE PLASTIC TYPE. 3. THIS CONTRACTOR SHALL VERIFY ALL ROUTING OF CONDUIT OUTSIDE THIS SPACE. 4. PAINTING OF LIGHT FIXTURES IS TO 8E BY THE CONTRACTOR FOR THE ARCHITECTURAL TRADES AT THIS CONTRACTOR'S EXPENSE- SEE SPECS AND FINISH SCHEDULE. 5. TfIIS CONTRACTOR SHALL SE RESPONSIBLE FOR PROPERLY BALANCING THE LOADS BETWEEN PHASE LEGS OF PANELS, REGARDLESS OF THE 'CIRCUIT NUMBERS SHOWN. 6. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFE AND PROPER STORAGE OF ALL ITEMS FURNISHED BY THE TENANT. ALL SHIPMENTS SI-IALL BE CAREFULLY CHECKED FOR DAMAGE AND SHORTAGES. ANY DAMAGE OR SHORTAGES SHALL BE NOTED ON THE TRUCKER'S FREIGHT BILL AND THE TENANT SHALL BE NOTIFIED IMMEDIATELY. 7. THE CIRCUIT DESIGNATED AS 'LA -42" ON TI-115 DRAWING SHALL BE RUN IN ITS OWN CONDUIT AND SHALL HAVE AN ISOLATED GROUND BACK TO THE POINT OF ORIGIN OF THE SERVICE GROUND. a. ALL WORK IS TO BE PERFORMED IN A SAFE AND LAWFUL MANNER AND SHALL COMPLY WITI -I ALL APPLICABLE CODES. 9. ALL WALL MOUNTED EXIT LIGHTS SHALL BE MOUNTED WITH THE BOTTOM OF FIXTURE FLUSH WITH THE TOP OF THE DOOR FRAME. 10. RECESSED CEILING SPEAKERS AND SPEAKER WIRE FURNISHED 4 INSTALLED BY AUDIO CONSULTANT. 11. COORDINATE ALL ELECTRICAL WORK IN CASH AND WRAP AREA WITH THE FLOORING CONTRACTOR, AS REQUIRED. 12. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH WE MANUFACTURERS' INSTRUCTIONS AND /OR RECOMMENDATIONS, AND GOOD INDUSTRY STANDARDS. IF THERE IS A CONFLICT, CONTACT A TENANT REPRESENTATIVE IMMEDIATELY. 13. ALL CONDUCTORS SHALL BE COPPER,, AND SHALL BE COLOR CODED TO CORRESPOND WITH THE LANDLORDS ELECTRICAL INSTALLATION. 14. THIS CONTRACTOR SHALL SE RESPONSIBLE FOR MAKING ALL NECESSARY HVAC ELECTRICAL CONNECTIONS. E.C. TO COORDINATE WIRING OF FAN, DAMPERS, HEAT COILS, AND CONTROLS W/ M.c. 15. THIS CONTRACTOR IS RESPONSIBLE FOR ANY NECESSARY ASSEMBLY OF LIGHT FIXTURES AND TRACK. ASSEMBLY SHALL BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 16. IF REQUIRED BY THE LANDLORD OR LOCAL BUILDING CODES, THIS CONTRACTOR SI-IALL COOPERATE WITH THE M.G. TO FURNISH AND INSTALL A FIRE AND SMOKE DETECTION SYSTEM, INCLUDING BUT NOT LIMITED TO, SMOKE DETECTORS, SMOKE , EXHAUST FANS, VISUAL AND AUDIBLE ALARMS, ETC. ALL EQUIPMENT MUST BE FULLY OPERABLE AND MEET LANDLORD AND LOCAL BUILDING CODE REQUIREMENTS. CONTACT THE TENANT REPRESENTATIVE WITH ANY DISCREPANCIES OR M15UNDERSTANDINGS. 1i �.� . ! o � ' t INSTALLS IN A PREVIOUSLY OCCUPIED SPACE. ALL CON .ACTORS SHALL "117 THE DIMENSIONS AND DETAILS S OHN ON 'THESE DRAHING5 HILL 5E C;CNPA T IT5L.F. 1IT1 e THE I TINE CONDITIONs. NOTIFY IFY TH TENANTS CONSTRUCTION DEPARTMENT IMMEDIATELY WITH ANY CONFLICTS. EACH CONTRACTOR SHALL BE RESPONSIBLE FAR ANY INCIDENTAL DEMOLMON OF NEVI INOPid REQUIRED By THE EXISTING CONDITIONS. SEE SPECS. 18. THIS CONTRACTOR SHALL VERIFY THE SIZE OF ANY EXISTING LOADS BEING REUSED (I.E., HVAC LOADS), THE SUITABILITY FOR THE DISCONNECTS, CONDUIT, WIRING, ETC. REVISE OR REPLACE AS REQUIRED. 19. THIS CONTRACTOR SHALL TI- IOROUGHLY INSPECT ANY EXISTING ELECTRICAL SERVICE AND PANELS, AND SHALL DETERMINE THE SUITABILITY OF ANY ITEM FOR THE NEW STORE. THIS WILL INCLUDE VERIFYING ACCEPTABLE CIRCUIT LOADS, BREAKER SIZES, DISCONNECT SIZES, WIRE SIZES, ETC. AND SHALL CONSIDER BOTH NEW AND EXISTING LOADS. 20. THE CIRCUITING INDICATED ON THISbRAWING IS TO SHOW LOAD GROUPINGS ONLY. THIS DRAWING SNOWS THE CIRCUITING AND 'I -HOME RUNS' FOR NEW ITEMS ONLY. EXISTING CIRCUITING MAY REMAIN IF SUITABLE. 21. THIS STORE IS BEING INSTALLED IN NEW SPACE. ALL CONTRACTORS SHALL VERIFY THAT THE USE OF THE DIMENSIONS AND DETAILS SHOWN ON TI -IESE DRAWINGS WILL BE COMPATIBLE WITH THE EXISTING CONDITIONS. NOTIFY THE TENANT'S CONSTRUCTION DEPARTMENT IMMEDIATELY WITH ANY CONFLICTS. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ANY INCIDENTAL DEMOLITION OR NEW WORK REQUIRED BY THE EXISTING CONDITIONS. SEE SPECS. 22. THIS CONTRACTOR SHALL 5E RESPONSIBLE FOR HVAC ELECTRICAL REQUIREMENTS, INCLUDING INSTALLATION OF 115 VOLT POWER WIRING AND CONDUIT FROM WE ELECTRICAL PANEL TO THE VARIABLE AIR VOLUME TERMINAL. 23. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLATION OF THERMOSTAT, ANY WIRING AND 115/24 VOLT TRANSFORMER TO THE VARIABLE AIR VOLUME TERMINAL. 24. THIS CONTRACTOR SHALL RELAMP ALL EXISTING LIGHT FIXTURES WITH LAMPS FURNISHED HY THE TENANT, USE THE LAMPS INDICATED ON THE FIXTURE SCHEDULE. 25. BRANCH BREAKERS SHALL BE BOLT -ON TYPE, WESTINGHOUSE 'BAB' OR 'GHB' SERIES OR EQUIVALENT. PANELS SHALL BE WESTINGHOUSE 'POW -R -LINE I' FOR 120/208 VOLTS AND 'POW -R -LINE 2' FOR 277/480 VOLTS, SEE SPECS. ROOF LINE 1VA( Iddd OR NO-I aRfSST - �r2 -97 -7 #I2 DEDICATED GRD. FOR CKT. "LA -42" BY E.C. N.T.S. PANEL "LA" TO CONTROLLED CIRCUITS RR7 RELAY LA -36- - I • LA -34 (4) #I2 THHN CU. 4 (1) #I2 GR. IN 3/4" C. AUTO SYSTEM (4) I/O # THHN CU. 4 (I) #6 GR. IN 2" C.- 480- 120/208V 43KVA XFMR ELECTRICAL RISER DIAGRAM VAV -1 PANEL " - (5) #4 TI-11-IN CU. 4 (1) #8 GR. IN 1 -I /4" C. #6 CU. GROUND TRANSFORMER MTD. 8' -0' A.F.F. TO BOTTOM OF UNIT. TENANT LANDLORD J 100A FU 100A CD RISER EQUIPMENT KEY Oi NEW PANEL "LA", IN STOCKROOM, 120/208V, 5 ?, 414, 150A MCB. CONFIGURE CIRCUITRY AS SHOWN ON DWG. 4 BALANCE LOADS ON ALL PHASES. GROUND PER NEC.- BY E.C. 0 CONDUIT AND CONDUCTORS AS REQUIRED FOR ALL CONTROLLED CIRCUITS. 0 (4) #1 THHN CU 4 (I) #S GR., BY TENANT E.G., IN 1 -1/2" LANDLORD CONDUIT. TENANT E.G. TO EXTEND CONDUIT 4 CONDUCTORS INTO TENANT'S SERVICE EQUI PMENT AS REQUIRED. ® LANDLORD'S SWITCHGEAR EQUIPMENT. SWITCH BY LANDLORD. E.G. TO MAKE FINAL CONNECTIONS AND INSTALL 100 AMPERE FUSES. VERIFY EXACT FUSE TYPE IN FIELD. ® MULTIPLE POLE, PROGRAMMABLE CONTACTOR, GE RR7, IN STOCKROOM. ® BUILDING AUTOMATION SYSTEM "ANDOVER' INTERFACE PANEL O NEV PANEL "HA ", IN STOCKROOM, 277 /430V, 5 ?, 4W, 100A MCE. CONFIGURE CIRCUITRY AS SHOWN ON DWG. 4 BALANCE LOADS ON ALL PHASES. GROUND PER NEC.- BY E.C. NOTE: ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ANY LOCAL AUTHORITY HAVING JURISDICTION. VERIFY LANDLORD'S SERVICE ARRANGEMENT IN FIELD. NOTE: THE INTERRUPTING RATING OF THE TENANTS BREAKERS SI -IALL NOT BE LESS THAN THE FAULT LEVEL AS DETERMINED BY THE LANDLORD'S ENGINEERS, AND IN NO CASE SHALL BE LESS THAN 14,000 A.I .C. FAR 480/277 VOLT PANELS OR 10,000 A.I.C. FJ12 208Y/120 VOLT PANELS. VERIFY EXACT FAULT CURRENT RATINGS WITH LANDLORD. X SIGNAL BELL AND TRANSFORMER PUSH BUTTON SINGLE POLE, 2 POLE SWITCH 3 -WAY, 4 -WAY SWITC4 SWITCH W/ PILOT LIGHT KEY OPERATED SWITCH DISCONNECT SWITCH m PULL BOX OR JUNCTION BOX MOTOR © THERMOSTAT r BRANCH CIRCUIT HOME RUN OVERHEAD ABOVE CEILING NL EM AFF DWC WP GFI E88 EDI ECH EUI-I GUH BU CEF REF ELECTICA SYMBOLS INCANDESCENT LIGHT FIXTURE AND FIXTURE TYPE WALL MOUNTED INCANDESCENT LIGHT FIXTURE AND FIXTURE TYPE INCANDESCENT TRACK FIXTURE AND FIXTURE TYPE RECESSED FLUORESCENT LIGHT FIXTURE AND FIXTURE TYPE FLUORESCENT STRIP LIGHT FIXTURE AND FIXTURE TYPE EXIT LIGHT ARROWS AS INDICATED AND FIXTURE TYPE EMERGENCY LIGHT, RECESSED, AND FIXTURE TYPE EMERGENCY LIGHT, SURFACE MTD., AND FIXTURE TYPE DUPLEX CONVENIENCE OUTLET DOUBLE DUPLEX CONVENIENCE OUTLET FLOOR MTD. DUPLEX CONVENIENCE OUTLET TELEPHONE OUTLET JUNCTION BOX BRANCH CIRCUIT 140ME RUN IN OR UNDER NIGHT LIGHT EMERGENCY LIGHT ABOVE FINISHED FLOOR DRINKING WATER COOLER WEATI -IER PROOF GROUND FAULT INTERRUPTER ELECTRIC BASEBOARD HEATER ELECTRIC DUCT HEATER ELECTRIC CABINET HEATER ELECTRIC UNIT HEATER GAS UNIT HEATER BATTERY UNIT CEILING EXHAUST FAN ROOF EXHAUST FAN ow osn FLOOR SLAB Mk( 0 51M a PERMIT CENTER FEB 292008 34,5 KENNETH L. BUTTS STATE OF WASHINGTON REGISTERED ARC ECT AfvO 4-; D NOM DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 1: 91g,-e 5 i 45ch ri OD W o w Z J� 4111 tz u) wQ �z ua 4 2751 Z 0 U In 0 n n EIRMEMEEMIlif EMIR igEtiENIZEZE ; " • I" CONDUIT BY E.C. - RUN ABOVE 12' -6'+ AFF FR4 TELEPHONE BACKERBOARD TO ALL FITTING ROOM LOCATION. STUB OUT ABOVE WALL LOCATION AS DICTATED BY FITTING ROOM WALL ARRANGEMENT. CEILING (IF APPLICABLE) PLYWOOD BACKBOARD FOR TELEPHONE EQUIPMENT BY G.C. DUPLEX RECEPTACLE ON DEDICATED CIRCUIT BY EC. 11" X 14" PAGING SYSTEM CONTROL PANEL BY PAGING SYSTEM VENDOR E.0.30 N.T.S. STOCKROOM NOTE: E.G. SHALL LEAVE 48" WHIPS AT CONTROL PANEL END (1 PER F. AA E.0.50 E.C. SHALL NEATLY FASTEN CAT CABLE ACROSS TOP OF PARTITION AND EXTEND DOWN INTO PARTITION AT DEVICE LOCATIONS (TYP) KEYPAD CONTROLLER BY PAGING SYSTEM VENDOR FITTING ROOM CALL 5UTTONS SCHEMATIC DETAIL OF AERJE FITTING ROOM CALL BUTTON N.T.S SALES /STOCK PARTITION CEILING NOTE: • E.G. gal -TALL RUN CAT 3 PLENUM RATED 2 PAIR, 24 ANG CABLE (PROVIDED BY PAGING SYSTEM VENDOR) THROUGH 1" CONDUIT FROM CONTROL PANEL TO LATCH SIDE OF EACH FITTING ROOM DOOR. E.C. SHALL DANGLE WIRE IN WALL CAVITY TO FUTURE LOCATION OF CALL BUTTON. (PROVIDE 18" OF WHIP FOR FINAL CONNECTION BY PAGING SYSTEM VENDOR) E.C. SHALL LEAVE REMAINING CABLE WITH SUPERINTENDENT FOR FINAL CONNECTIONS BY PAGING SYSTEM VENDOR. ALL DEVICES, INSTALLATION CUT -OUTS AND FINAL CONNECTIONS BY PAGING SYSTEM VENDOR. RESET BUTTON ON PASSAGE SIDE CEILING OF FITTING ROOM PARTITION BY PAGING VENDOR. (LOCATE CENTERED ON DOOR CASING) > > I = AERIE FITTING ROOMS (IF APPLICABLE) CALL BUTTON ON FITTING ROOM SIDE OF PARTITION BY PAGING VENDOR. (LOCATE CENTERED ON DOOR CASING) NOTE: ENSURE THAT "AERIE" BIRD IS ROTATED TO LOOK AS IF IT I5 TAKING FLIGHT, FACING UPWARD RESET BUTTON ON i PASSAGE SIDE OF FITTING ROOM PARTITION BY PAGING VENDOR. (LOCATE 6" FROM DOOR CASING LATCH SIDE OF DOOR SEE DETAIL AA/E.0.3) CALL BUTTON ON FITTING ROOM SIDE OF PARTITION BY PAGING VENDOR. (LOCATE 6" FROM DOOR CASING • LATCH SIDE OF DOOR) Signed RECEIVED CITY OF TUKWILA FEB B 4 2008 PERMIT CENTER Y 9estIie k[ Working Drawing Review A Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only- All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir • to be kept on the job site at all times. 1 /3/08 NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON 11-115 SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PRCUECT. f EIRMEMEEMIlif EMIR igEtiENIZEZE ; " • I" CONDUIT BY E.C. - RUN ABOVE 12' -6'+ AFF FR4 TELEPHONE BACKERBOARD TO ALL FITTING ROOM LOCATION. STUB OUT ABOVE WALL LOCATION AS DICTATED BY FITTING ROOM WALL ARRANGEMENT. CEILING (IF APPLICABLE) PLYWOOD BACKBOARD FOR TELEPHONE EQUIPMENT BY G.C. DUPLEX RECEPTACLE ON DEDICATED CIRCUIT BY EC. 11" X 14" PAGING SYSTEM CONTROL PANEL BY PAGING SYSTEM VENDOR E.0.30 N.T.S. STOCKROOM NOTE: E.G. SHALL LEAVE 48" WHIPS AT CONTROL PANEL END (1 PER F. AA E.0.50 E.C. SHALL NEATLY FASTEN CAT CABLE ACROSS TOP OF PARTITION AND EXTEND DOWN INTO PARTITION AT DEVICE LOCATIONS (TYP) KEYPAD CONTROLLER BY PAGING SYSTEM VENDOR FITTING ROOM CALL 5UTTONS SCHEMATIC DETAIL OF AERJE FITTING ROOM CALL BUTTON N.T.S SALES /STOCK PARTITION CEILING NOTE: • E.G. gal -TALL RUN CAT 3 PLENUM RATED 2 PAIR, 24 ANG CABLE (PROVIDED BY PAGING SYSTEM VENDOR) THROUGH 1" CONDUIT FROM CONTROL PANEL TO LATCH SIDE OF EACH FITTING ROOM DOOR. E.C. SHALL DANGLE WIRE IN WALL CAVITY TO FUTURE LOCATION OF CALL BUTTON. (PROVIDE 18" OF WHIP FOR FINAL CONNECTION BY PAGING SYSTEM VENDOR) E.C. SHALL LEAVE REMAINING CABLE WITH SUPERINTENDENT FOR FINAL CONNECTIONS BY PAGING SYSTEM VENDOR. ALL DEVICES, INSTALLATION CUT -OUTS AND FINAL CONNECTIONS BY PAGING SYSTEM VENDOR. RESET BUTTON ON PASSAGE SIDE CEILING OF FITTING ROOM PARTITION BY PAGING VENDOR. (LOCATE CENTERED ON DOOR CASING) > > I = AERIE FITTING ROOMS (IF APPLICABLE) CALL BUTTON ON FITTING ROOM SIDE OF PARTITION BY PAGING VENDOR. (LOCATE CENTERED ON DOOR CASING) NOTE: ENSURE THAT "AERIE" BIRD IS ROTATED TO LOOK AS IF IT I5 TAKING FLIGHT, FACING UPWARD RESET BUTTON ON i PASSAGE SIDE OF FITTING ROOM PARTITION BY PAGING VENDOR. (LOCATE 6" FROM DOOR CASING LATCH SIDE OF DOOR SEE DETAIL AA/E.0.3) CALL BUTTON ON FITTING ROOM SIDE OF PARTITION BY PAGING VENDOR. (LOCATE 6" FROM DOOR CASING • LATCH SIDE OF DOOR) Signed RECEIVED CITY OF TUKWILA FEB B 4 2008 PERMIT CENTER Y 9estIie k[ Working Drawing Review A Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only- All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir • to be kept on the job site at all times. 1 /3/08 NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON 11-115 SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PRCUECT. MEM GENERAL PLUMBING SPECIFICATIONS Gl. MATERIALS (a) All materials shall be new and the best of their respective kinds, aid shall conform to all standards or requirements governing the same, and shall be approved by Tenant's Construction Department before being installed. Where specific manufacturer or trade name is mentioned in the specifications, it is to establish a standard of quality. Substitution of other makes that may be judged equal by Tenant's Construction Department may be made only by its authority in writing, and must be made prior to time of bid. All materials shall be in accordance with code requirements and as follows: G2. FIXTURES (c - l) Domestic hot water lines and cold water lines shall be copper tubing with soldered fittings and adapters. Above ground copper pipe shall be hard temper Type L. Underground copper pipe shall be soft temper Type K. Use solder for connections underground. (c -2) Valves 2" and smaller shall be of brass body. Valves 2 -1/2" and larger shall have cast iron bodies and bronze sterns and seats, brass trimmed, and may be either gate, or globe with Jenkins disc. Type depends upon which is most suitable for the application. (c -3) Shut -offs shalt be straightway finished brass compression stop and waste cocks. (c -4) Valves and cocks shall be Apollo, Jenkins, Crane, Powell, Walworth, or approved equal, good for a working pressure of 125 psi. Valves shall be installed with union near some to permit easy removal. (c -5) Unions on joints up to 2" diameter shall be 300 lb. Kewanee, Dart or Crane ground joint unions. Unions on pipe 2 -1/2" and above shall be standard companion flanges. Unions on copper lines shall be brass. Furnish and install Epco #5 isolating unions with Durable gasket between runs of copper and steel pipe or equipment. Dielectric couplings are not permitted. (c -6) Sail pipe and fittings shall be service weight cast iron coated with asphaltum. (c -7) Waste and vent piping above round shall be service weight cast iron or galvanized steel with recessed cast iron drainage fittings coated with asphaltum, or DPW copper. m (c - 6) Floor drains shall be Josa's 30000 -AJ Series or approved equal with 5' diameter CP brass strainer and C.I. trap, or with 7" diameter CP brass funnel strainer and C.I. trap as indicated on the plans. Note: Caulk and seal around perimeter. Cleanouts in floor shall be Josam 56000 Series or approved equal, set in locations as required. Cleanouts in areas receiving wood flooring shall be set flush with finished floor and shall have brass cover plates. (c -I0) Pipe sleeves shall be two pipe sizes larger than pipe, and shall be wrought iron through masonry walls or beams, and galvanized iron in all other locations. (c -II) Pipe hangers shall be expansion hangers with sectional rings. Piping on wall shall be supported with standard hook plates. Spacing of hangers shall be as required_ (c -12) Escutcheons an piping through walls, floors and ceilings shall be adjustable type split CP brass except in service portions which shall be cast iron, plain finish. (a) Fixtures shall be Class 'A' vitreous china porcelain enameled cast iron as indicated in the Supplemental Specification and shall be unmarked, clear, smooth and bright, and shall be guaranteed not to crack, discolor, or scale. Fixtures, fittings and installation shall comply with ADA regulations. Fixtures shall be Kohler Co., as listed in the Supplemental Specification, Eljer, Elkay, Crane Co., or approved equal. The rims, fronts, and all exposed parts of lavatories, urinals, service sinks, water closets, drinking fountains and other fixtures shall be covered an d protected with suitable guards and building paper and such shall be maintained until completion of the work. This protection shall be installed immediately at the time of setting the plumbing fixtures and shall be removed only when directed by Tenant's Construction Department. The Plumbing Contractor shall be responsible for all damage to fixtures and shall make good any damage without additional cost to the Owner. The Plumbing Contractor shall install all fixtures complete, with alt required water, waste and vent corwtections, together with all fittings, structural supports, faucets, valves and traps. All faucets shall have renewable units, seat and barrel. Faucets, exposed fittings, valves, etc., and exposed piping at fixtures shall be chrome plated brass. Pipe shall be brass pipe of standard iron pipe sizes, chrome plated and fitted with chrome plated brass escutcheons of approved design. G3. CHARACTER OF PIPE WORK All soil and waste lines shall have a uniform drop of not less that I /S" per foot. All connections to domestic hot water and cold water branches shall be taken off the mains with approved swing joints. Valve each branch at the main. Valve each group of fixtures. All exposed piping shall be installed neatly in straight lines parallel to the building lines and as close to the walls and ceilings as is consistent with good workmanship. All openings in pipes must be capped or plugged during the Construction. (d) The Contractor shall offset his work as directed in order to allow other Constrictors to install their work, to avoid interference with other piping or ducts, and to conceal the pipes more readily or to allow for greater head room under the pipes. All piping in finished rooms shall be concealed in ceilings, partitions, or chases where possible, and as directed. G4. PIPE INSULATION (a) All domestic cold and hot water lines shall be covered with 1" thick Fiberglass sectional pipe covering, with factory - applied jacket, or 3/5" m thick Araflex. Hot water supply and drain pipes under lavatories shall be similarly insulated. (b) Valve bodies and fitting the above covered lines shall be covered with I" thick molded glass fiber insulation wrapped firmly under compression 2:1 with copper class wire. Finish with S oz. canvas jacket smoothly pasted on. Provide vapor barrier for lines. Repair damage to present insulation where new connections have been made, in conformity with the above specifications. (d) All insulation shall be Owens- Corning, Certaintee, Manville or approved equal. JOB SPECIFIC PLUMBING SPECIFICATIONS SI. PLUM SPECIFICATIONS (a) This Contractor shall tnape4t the existing plietbinq system and shall ply into first -class condition, Rod out sail waste `Ines. rs Iii new wsasher6 In Poi ets, clean rcbush traps. C k car leaks. (b) This Cant.�octsar ehtail -_ t t st.ionable canditi `t. � •st valve, install the Floor drain t rrlvsr-t to Funnel typ it refired. Ext condensate drvi.', end water Greater pre ure reli�sE drains to flair drain. install G trap Primer, 52. SERVICE FAUCET Furnish and install a hot and cold mixing service faucet beneath the Lavatory. Faucet shall be a Kohler Model 14X Knoxford rough plated faucet with vacuum breaker, threaded spout, pail hook, and base key integral stops. S3. HANDICAPPED WATER CLOSET (a) Water Closet shall be Koh lers 'ADA Highline' #K -3427, white vitreous china, bolt -on, syphon jet, elongated bowl with close coupled tank, anti syphon float valve, Brass Craft C540IDL supply kit, qu and Bemis #I250TT solid plastic open seat with cover. (Acceptable eal by Eljer: Water Closet #011 -3674, angle valve supply #802- 0225). 54. HANDICAPPED LAVATORY (a) Handicapped Lavatory shall be Kohlers #K -2032 'Greenwich', white vitreous china lavatory Fitted with a Faucet as manufactured by Tits Brass t Sraize Works, Inc. #B -0892 with 4 lever type control handles, gooseneck spout, aerator, and pop -up drain; I -I/4' IGA CP PTRAP L /CO DON F. Erasscraft CS400A Supply kit. Lavatory shall be drilled for a concealed arm carrier and provided with wall brackets. (Acceptable equal by Eljer: Lavatory #051 2644, 802 - 0225 Angle Valves, 'P' trap #802 - 1100). (b) (b) Lavatory to be wall mounted 29' above the floor to the bottom of apron. S5. 5!RVIC! SINK (a) eer -Vi.ct sink shall be Kahiers ' Ilan' #K -6716 #K- lea stainl sal rim Guard. It rraugh p1 . d Pave*, wit • I A k e trap with clew ut pt; P .� . , _ 5- orvic -e Simi. 4242 -050, rim pus 'd W5-0180, Crap 4H1s 97. HANDICAPPED DRINKING FOUNTAIN S,E=R`VICE BASIN I ( €a) Map i. II Basin l mol d �I°lall hems a stdo:- tc. I ^a , ss e$i - - �d��basket,. Provide •ald inst:;si i s D !c �, i 1 s • i e f r � c pl•ete with vezuurw _. ,� „ . -Ir mss, lsuil ivok, lase and bracket, nap l . replace iF hl t and relief sr wr: ;tesa cast iron, #K -f5 : h k, and #K -6673 .. •Ie er la! by F1 j r: fagot 1174q-050-0, Drinking Fountain shall be wall mounted, non - refrigerated, #304 stainless steel, with anti - splash ridge, integral strainer, bubbler with front push bar or lever handle and pressure regulator. Elkay Model #EDFP214C. "a8. FIXTURE CONNECTIONS (a) Each Fixture shall have a shut - off valve at the fixture, adjusted to prevent excessive pressure. (b) The size of piping comections to fixtures shall be as follows: (c) These sizes are For short branches only; main lines shall be installed of the size as indicated on the plans, or as required by State and local codes. FIXTURE SOIL or WASTE VENT TRAP HOT WATER COLD WATER Water Closet 4' 2' "" I /2" L 1 1/2" 1 1/2" I I/2' I /2" I/2' Service Faucet -- -- -- 1/2" I/2' Drinking Fountain 1 1/2" 1 1/2" 1 1 /2" -- I /2" Map Basin 4" 4" 4p I /2" I/2' Service Sink 2' 2" 2a 1/2' I /2' Sq. ELECTRIC WATER HEATER (a) Furnish and install in location as indicated an plan, A.O. Smith ( #DEL -69), Lochinvar or approved ecyal glass tined, electric water heater, 6 gallon storage capacity, 1500 watt heater capacity, wired For 115 volts single phase, 60 cycle, A.C., complete with combination pressure and thermostatic relief valve piped to discharge over 22' aluminum drain pan or floor drain and all centrals as required for a complete automatic system. (b) Furnish ale ims+.oll in location r i ,ed on plan, Chron-omits Laborrtori , Inc., Model S- 30L /ilaU , I. Inset Plow, clecfiric aster h . -tt E r It, . warred car 115 vol si ie glass 60 .,. . .r* ritti contrcis es recaired fo:- a cc mplete automatic system. Chr rtamita; is bortiato~ies, iro.; 21011 5. Fiaueioa; C,,ar an, CA 9O745, (: -447 -4). PLUMBING SPECIFICATIO GENERAL PLUMBING NOTES THE EXISTING PLUMBING SYSTEM FOR THE TOILET RI VALL BE REUSE'G. T1416 CONTRACTOR SP?I HATER HEATERS AREINAKI4 l;ORli OU T sr lTTERS' REPRESi:. ' CONDITION, REPLACE AS DIRECTED. INSTALL MIXING FAUCET'. "E EXI5`T'ING PLUMBING SYSTEM HIS CONTRACTOR SMALL / ` � HATER I -4EA T ERS ARE ,' rr OUTFITT,I�RS' REFRESE. r { CNDI P ION. REPLACE ; 5 DIRECTED. CONNECT TO LANDLORD PROVIDED SANITARY MAIN VERIFY LOCATION WITH L.L. REP. DRINKING FOUNTAIN 1 1/2" S4IALL Br REUSED AS MUCH A$ P05515LE. Tt :. � .. I� :i*NG DRAINS, F!X T'URE.S, AND l cD , NOTIFY° AMERICAN EAGLE tklCt4 ARE IN O lESTIONABLE NO SCALE Ii iIC, DRAINS, FIXTURES, AND D R, NOTIFY AMERICAN EAGLE l ~°I iNH1CH ARE IN Q {UEST1ONA.BLE NSTALL FLOOR DRAIN IN NONE 15 EXISTING, 3. THIS CONTRACTOR 51-IALL VERIFY WITH THE LANDLORD THE EXACT LOCATION FOR SANITARY TAP IN. PATCH ALL CONCRETE INSIDE AND OUTSIDE THE SPACE AS REQUIRE BY THE NEW SANITARY SYSTEM. 3" VENT CONNECT TO VENT CONNECTION VERIFY EXACT CONNECTION LOCATION AND CONDITIONS. CONNECT TO • VALVED COLD WATER STUB ) 3/4" WITHIN AMERICAN EAGLE'S LC DEMISED PREMISE. VERIFY LOCATION WITH L.L. REP. 3" VENT CONNECT TO VENT CONNECTION VERIFY EXACT CONNECTION LOCATION AND CONDITIONS. CONNECT TO LANDLORD PROVIDED SANITARY MAIN VERIFY LOCATION WITH L.L. REP. \5/ETA L.S SANITARY RISER DIAGRAM NOTES ALL DRAIN PIPING PENETRATING THE FLOOR MUST BE SEALED PER LANDLORD CRITERIA_ N.T.S. H.C. LAV 11/2" CLEAN - OUT DRINKING FOUNTAIN mmmOmmmmr F 'l A FLOOR DRAIN MIXING FAUCET — MTD IS" A.F.F. ABV FLOOR DRAIN WATER HEATER ABOVE TOILET ROOM CEILING. SEE NOTES, PIPING DIAGRAMS, AND SPECS. H.C. LAV 0 CLEANOUT ENLARGED TOILET ROOM PLAN CONNECT TO VALVED COLD WATER STUB WITHIN AMERICAN EAGLE'S DEMISED PREMISE. VERIFY LOCATION NITA L.L. REP. NOTE: IF REQUIRED, THIS CONTRACTOR IS RESPONSIBLE FOR FURNISHING A WATER METER PER LANDLORD REQUIREMENTS IN AN ACCESSIBLE LOCATION. BALL VALVE (TYP) WATTS MODEL 00SQT VACUUM BREAKER (ONLY IF REO'D) 6 GALLON ELECTRIC WATER HEATER ON DECK ABOVE TOILET ROOM. SEE CHART, NOTES, AND SPECS P/T RELIEF VALVE EXTEND DRAIN TO SAME SIZE AS VALVE DISCHARGE 3" DEEP GALVANIZED PAN VI/SOLDERED JOINTS. —7 SAFE WASTE TO FLOOR DRAIN. THERMAL EXPANSION TANK SIZED PER LOCAL CODES (ONLY IF REQ'D) 7 -WATTS SERIES 009 3/4' BACKFLOW PREVENTER (ONLY IF REQ'D) 3/4" MIXING FAUCET (MEN'S ROOM) WATER PIPING DIAGRAM N.T.S. NOTES : ALL EXPOSED WATER AND DRAIN PIPING UNDER THE LAV SHALL BE INSULATED TO AVOID CONTACT WITH SHARP OR ABRASIVE SURFACES. Wsfflek{ Working Drawing Review A pproved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor- Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is requir tope kept on the job site at all times. a 1 /3/08 Signed Date 1/2" / 1 /2" CIT OF RECEIVED FEB 0 + 2003 PERMIT CENTER NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO T1416 PROJECT. 4 on an Cs4 cr 8 O c*Il DRAWING NUMBER DRAWING DESCRIPTION EMS COVER SHEET EMS.1 FLOOR PLAN WITH EMS DATA EMS.2 ANDOVER SYSTEM ARCHITECTURE EMS.3 MAIN ANDOVER INTERFACE PANEL EMS .4 FPVAV -1 CONTROLLER INPUT WIRING DETAILS EMS.5 FPVAV -1 CONTROLLER OUTPUT WIRING DETAILS EMS.6 GE SOFTWIRE PANEL DETAILS EMS.7 EMS.8 GE SOFTWIRE PANEL PROGRAMMING & WIRING DETAILS SPECIFIC SENSOR WIRING DETAILS X 4 t= '111 E=1 I N 1111111111111 stm f751 nmvms No. EMS ENERGY MANAGEMENT SYSTEM BY ROTH BROS., INC. FOR AMERICAN EAGLE OUTFITTERS SOUTHCENTER MALL TUKWILA, WA Space #2120 DRAWING INDEX Review all drawings before starting EMS install. All questions should be directed to: Klaye Kasten 330 - 559 -4192 (Primary) 1. THE AMERICAN EAGLE STORES INC. ELECTRICAL CONTRACTOR SHALL BE DENOTED BY EC. 2. ALL LOCAL AND NATIONAL CODES SHALL BE FOLLOWED. 3. EC- IS RESPONSIBLE TO SUPPLY 120 VOLT POWER AS INDICATED ON DRAWINGS. 4. THE EC SHALL BE RESPONSIBLE FOR RUNNING ALL CABLES AND WIRES TO INDICATED LOCATIONS AS SHOWN ON PRINT, AND MAKING ALL TERMINATION'S FOR A COMPLETE AND FULLY FUNCTIONAL ANDOVER EMS SYSTEM PROVIDED BY ROTH BROS. INC. 5. THE EC- SHALL LABEL ALL CABLES ON 5OT1-1 ENDS ACCORDING TO THESE DRAWINGS. G. THE EC- SHALL WORK WITH ROTH BROS., INC. PERSONNEL VIA THE PHONE FOR STARTUP AND ENTIRE SYSTEM CHECKOUT. 7. EC WILL CONTACT ROTH BROS., INC. FACILITIES AUTOMATION DIVISION AT OUR YOUNGSTOWN OFFICE AFTER COMPLETION OF ALL TERMINATIONS (CONDUIT, WIRE RUNS, ETC.) AT 1 -BOO- USA - ROTA. (Man --Fri 8:OOAm 5:00PM EST) S. EC SHALL CALL ROTH BROS INC. 48 HRS PRIOR TO NEEDING THE SYSTEM STARTUP AND SYSTEM VALIDATION TO SCHEDULE A DATE AND TIME TO PERFORM. 9. ALL SENSORS, AND ANDOVER PANEL EMS EQUIPMENT SHALL SE FURNISHED BY ROTH BROS., INC. 10. ALL TERMINAL STRIPS, FASTENERS, CONNECTORS AND LOW VOLTAGE CABLE REQUIRED FOR A COMPLETE FUNCTIONAL EMS SYSTEM, SHALL BE FURNISHED BY THE EC. 1 1 . LOW VOLTAGE CONTROL WIRING SHALL NOT BE RUN I N THE SAME RACEWAY AS LINE VOLTAGE WIRES, NOR BE RUN NEAR HIGH VOLTAGE EQUIPMENT WI-IEN NOT or Warner Lawson 330 - 518 -2224 (Secondary) R.0T14 BROS. AFirstEnagy Company AIR CONDITIONING • HEATING • ROOFING • NATIONAL AVAC SERVICE LIGHTING * ENERGY SERVICES * FACILITIES AUTOMATION • SHEET MEDAL YOUNGS OWN BRANCH: 3247 CRUM ROAD * P.O. 130X I YOUNSETTIWN, Oi1044515 * PHONE Q30) 7934571 T A M P A B R A N C L 6 5411 BEAUMONTCENTER B L V D . S 5715. T A M P A , FLORIDA 33634•5293 • PUc E 13)3434303 FT. LAUDERDALE BRANCH: 541 S. STATE ROAD 7 * SHIM 13 • MARGAT$ FLORIDA 33061 * P111111054) 9704079 ORLANDO BRANCH: 2471 SAND LAKE ROAD * ORLANDO, FLORIDA 32109.7673 * PMNE(407)438•430 OFFICES 1/4: YOUNGSTOWNMO • AKRON. OM • CLEVELAND. OIL • COLUMBUS, OM • CINCINNATI, OM • DE1ROMMICIHi4AN BALTIMORE, MARYL ON) • FT. LAUDERDALE, E DALE PUMA • ORLANDO, FLORIDA • TAMPA, PIMA • PITTSBURGH, PENNSYLVANIA EMS NOTES: 12. EC TO INSTALL SYSTEM ACCORDING TO JOB SPECIFICATIONS. 13. TEMPERATURE SENSOR TO BE MOUNTED AWAY FROM DIFFUSER. 14. ALL CONDUIT, JUNCTION BOXES, TROUGHS, ETC. SHALL BE FURNISHED BY EC. 15. ALL CONVENTIONAL THERMOSTAT INTERFACE CARDS SHALL BE PROVIDED AND INSTALLED BY THE AMERICAN EAGLES INC. MECHANICAL CONTRACTOR. 16 ANY QUESTIONS OR DEVIATIONS CONCERNING THESE DRAWINGS OR THE ENER MANAGEMENT SYSTEM IN GENERAL SHOULD BE BROUGHT TO THE ATTENTION OF ROTH BROS., INC. 17.T.C.E.C. TO FURNISH ROTH BROS., INC. ONE (1) SET OF MARKED-UP DRAWINGS SHOWING EXACT LOCATIONS OF ALL WIRE PULLS, JUNCTION BOXES, RELAY PANELS, AND SENSOR LOCATIONS AT THE COMPLETION OF THE PROJECT. 18. NO WIRE NUTS OR SPLICES ALLOWED ANYWHERE IN THE WIRING NETWORK 1q. ALL 120V POWER FEEDS FOR THE ENERGY MANAGEMENT CONTROL PANELS SHALL BE RUN IN ITS OWN CONDUIT AND NOT ROUTED THROUGH ANY CONTROL PANEL OR I N THE SAME CONDUIT AS CONTROL WIRING . Si ned a Dos 05D RECEIVED CITY OF TUKWILA FEB 0 42'"PS PERMIT CENTER es ie 41 Working Drawing Review,_;' Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- • to be kept on the job site at all times. � � i a t __ 10, _ 1 /3/08 Date I cn I / • • • • a "E" LEVEL SWITCH SPST SWITCH ("STOCK ROOM ") FOR Rolling Brownout Control 2 -16GA TFFN conductors to main Andover interface. See EMS -5 and EMS -6 for final terminations. FPVAV -1 Controller N, imminimm 23 -2 0 TO MAIN INTERFACE PANEL • • • New Andover Interface Panel. See EMS -5 For WiringDetails. "F" LEVEL SWITCH SPST SWITCH ( "50% FITTING ") FOR 2 -16GA TFFN conductors to main Andover interface. See EMS -5 and EMS -8 for final terminations. • • 7411F • • R — I -- — Stock Room PIR IBGA -4 conductor to main andover interface. See EMS -2 $ EMS -8 for final terminations. • • LEL _ • • • "B" LEVEL SWITCH SPST SWITCH ( "50% SALES ") FOR 2 -I6GA TFFN conductors to main Andover interface. See EMS -3 and 301 - EMS -8 for final terminations. SCALE: 1/4" I' - 0" • y11 - 1 811 • • v MECHANICAL PLAN • ■ • AIL "© • Sales Area PIR 18GA -4 conductor to main andover interface. See EMS -2 4 EMS -8 for final terminations. • 30 - D El • Smart Sensor to be Mounted 5' AFF TO FPVAV -1 Controller • • • • • • • 22' -I 0 • • • • i i I 1 0 iii 1 i in cn si•ned cn V?estf/e[d RECEIVED CITY OF TUKWILA FEB B 4 ?i1C8 PERMIT CENTER Working Drawing Review A Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- . to be kept on the job site at all times. 1/3/08 Date ,A% C- (4 0 .1R -44- 'fin 1 mt" AT � ,-.1 ,..moci z W • E u-v co 2 751 1 — F i VAV -1 SPACE TEMP SENSOR —E; SUPPLY AIR TEMP See drawing EMS -6 and EMS -7 terminations.. 6 -16GA TFFN CONDUCTORS IN RACEWAY TO 3 WALL SWITCHES FOR ROLLING BROWNOUT CONTROL. S M5-1 FOR LOCATIONS. SEE EMS -3 it EMS -7 FOR TERMINATIONS. NOTE: ROLLING S ONNOUT SWITCHES WILL NOT BE INSTALLED IN AERIE STORES. VAV-1 1 120 /60 /1 DEDICATED CIRCUIT FOR ANDOVER or GE LIGHTING PANEL (RR -7) See drawing EMS -4 For terminations and mounting location. See drawing EMS -1 For VAV Terminal Box locations. INF. COMMUNICATION WIRE FROM MAIN ANDOVER INTERFACE PANEL TO FIRST VAV I N SEQUENCE. SEE EMS -1 FOR VAV TERMINAL IBOX QUANTITIES, LOCATIONS, AND COMMUNICATION WIRE PULLS. STOCK RM ENTRY WAY FIR FIR VAV BOX CONTROLLER(S) Q ADD ❑VCR INTERFACE PANEL IN ELECT R V 7 -16GA TFFN CONDUCTORS FOR FOUR LEVELS OF LTG CONTROL 12 + VAC CONTROLLER POWER BY EC. INF. COMMUNICATION WIRE FROM PREVIOUS V I N SEQUENCE TO NEXT VAV I N SEQUENCE (IF APPLICABLE). SEE EMS -1 FOR VAV TERMINAL BOX QUANTITIES, LOCATIONS, AND COMMUNICATION WIRE PULLS. PIRS VAV -# SPACE TEMP SENSOR See drawing EMS -3 & EMS -10 For terminations. See Drawing EMS -1 for mounting location. CAT -5 CABLE TO STORE POUTER NOT TO EXCEED 300 FEET TOTAL See drawing EMS -3 For terminations. See Drawing EMS -1 for mounting location. 1 SUPPLY AIR TEMP VAV - # 11 ARCHITECTURE FOR VAV--# SHOWN ABOVE IS TYPICAL FOR EACH ADDITIONAL VAV BEYOND THE FIRST (I.E. VAV-2, VAV-3, ETC . ) D INF. COMMUNICATION WIRE TO NEXT VAV IN SEQUENCE (IF APPLICABLE). Wslfie[c[ Si ned Date RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER Working Drawing Review A pproved A pprove pp as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- • to be kept on the job site at all times. F 1/3/08 LU 4 4 U) 7 S an :4• • o '• 1 II [[rF I A* ::] d tl_ - - -� �, INM7= l i ma �r elms ■ II= y� an l Ihifi EINEM —I Mir —I MP I D i VAV -1 SPACE TEMP SENSOR —E; SUPPLY AIR TEMP See drawing EMS -6 and EMS -7 terminations.. 6 -16GA TFFN CONDUCTORS IN RACEWAY TO 3 WALL SWITCHES FOR ROLLING BROWNOUT CONTROL. S M5-1 FOR LOCATIONS. SEE EMS -3 it EMS -7 FOR TERMINATIONS. NOTE: ROLLING S ONNOUT SWITCHES WILL NOT BE INSTALLED IN AERIE STORES. VAV-1 1 120 /60 /1 DEDICATED CIRCUIT FOR ANDOVER or GE LIGHTING PANEL (RR -7) See drawing EMS -4 For terminations and mounting location. See drawing EMS -1 For VAV Terminal Box locations. INF. COMMUNICATION WIRE FROM MAIN ANDOVER INTERFACE PANEL TO FIRST VAV I N SEQUENCE. SEE EMS -1 FOR VAV TERMINAL IBOX QUANTITIES, LOCATIONS, AND COMMUNICATION WIRE PULLS. STOCK RM ENTRY WAY FIR FIR VAV BOX CONTROLLER(S) Q ADD ❑VCR INTERFACE PANEL IN ELECT R V 7 -16GA TFFN CONDUCTORS FOR FOUR LEVELS OF LTG CONTROL 12 + VAC CONTROLLER POWER BY EC. INF. COMMUNICATION WIRE FROM PREVIOUS V I N SEQUENCE TO NEXT VAV I N SEQUENCE (IF APPLICABLE). SEE EMS -1 FOR VAV TERMINAL BOX QUANTITIES, LOCATIONS, AND COMMUNICATION WIRE PULLS. PIRS VAV -# SPACE TEMP SENSOR See drawing EMS -3 & EMS -10 For terminations. See Drawing EMS -1 for mounting location. CAT -5 CABLE TO STORE POUTER NOT TO EXCEED 300 FEET TOTAL See drawing EMS -3 For terminations. See Drawing EMS -1 for mounting location. 1 SUPPLY AIR TEMP VAV - # 11 ARCHITECTURE FOR VAV--# SHOWN ABOVE IS TYPICAL FOR EACH ADDITIONAL VAV BEYOND THE FIRST (I.E. VAV-2, VAV-3, ETC . ) D INF. COMMUNICATION WIRE TO NEXT VAV IN SEQUENCE (IF APPLICABLE). Wslfie[c[ Si ned Date RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER Working Drawing Review A pproved A pprove pp as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- • to be kept on the job site at all times. F 1/3/08 LU 4 4 U) 7 S an :. I , : i HUI INM7= l i ma �r elms 'CM l Ihifi EINEM —I MP I D / i VAV -1 SPACE TEMP SENSOR —E; SUPPLY AIR TEMP See drawing EMS -6 and EMS -7 terminations.. 6 -16GA TFFN CONDUCTORS IN RACEWAY TO 3 WALL SWITCHES FOR ROLLING BROWNOUT CONTROL. S M5-1 FOR LOCATIONS. SEE EMS -3 it EMS -7 FOR TERMINATIONS. NOTE: ROLLING S ONNOUT SWITCHES WILL NOT BE INSTALLED IN AERIE STORES. VAV-1 1 120 /60 /1 DEDICATED CIRCUIT FOR ANDOVER or GE LIGHTING PANEL (RR -7) See drawing EMS -4 For terminations and mounting location. See drawing EMS -1 For VAV Terminal Box locations. INF. COMMUNICATION WIRE FROM MAIN ANDOVER INTERFACE PANEL TO FIRST VAV I N SEQUENCE. SEE EMS -1 FOR VAV TERMINAL IBOX QUANTITIES, LOCATIONS, AND COMMUNICATION WIRE PULLS. STOCK RM ENTRY WAY FIR FIR VAV BOX CONTROLLER(S) Q ADD ❑VCR INTERFACE PANEL IN ELECT R V 7 -16GA TFFN CONDUCTORS FOR FOUR LEVELS OF LTG CONTROL 12 + VAC CONTROLLER POWER BY EC. INF. COMMUNICATION WIRE FROM PREVIOUS V I N SEQUENCE TO NEXT VAV I N SEQUENCE (IF APPLICABLE). SEE EMS -1 FOR VAV TERMINAL BOX QUANTITIES, LOCATIONS, AND COMMUNICATION WIRE PULLS. PIRS VAV -# SPACE TEMP SENSOR See drawing EMS -3 & EMS -10 For terminations. See Drawing EMS -1 for mounting location. CAT -5 CABLE TO STORE POUTER NOT TO EXCEED 300 FEET TOTAL See drawing EMS -3 For terminations. See Drawing EMS -1 for mounting location. 1 SUPPLY AIR TEMP VAV - # 11 ARCHITECTURE FOR VAV--# SHOWN ABOVE IS TYPICAL FOR EACH ADDITIONAL VAV BEYOND THE FIRST (I.E. VAV-2, VAV-3, ETC . ) D INF. COMMUNICATION WIRE TO NEXT VAV IN SEQUENCE (IF APPLICABLE). Wslfie[c[ Si ned Date RECEIVED CITY OF TUKWILA FEB 0 4 2008 PERMIT CENTER Working Drawing Review A pproved A pprove pp as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- • to be kept on the job site at all times. F 1/3/08 LU 4 4 U) 7 S 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 6)(1-1)7 s JD 0 !SnX 0 5G O 10 X2 ®® 11 X2 S 0 S 0 5 0 ,5 0, 5 0 5 0 S 0 5 0 S 0 5 0 5 0 5 0 S 0, S 0 5 0 5 0 1 5 0 5 0 5 01 5 0 15 0 ( INTERFACE PANEL AMERICAN EAGLE OUTFITTE � Southcenter Mall Tukwila, WA Spweft 2120 1 � KENNETH L. BUTTS, ARCHITECT Bell Cany CA 91307 .�$ 81 .999 -472 AMERICAN EAGLE OUTFITTERS 150 Them Hill Dr. - P.O. 788 W dale, Pe. 15095 (724) 776 -4857 :til.= .Fi, ".. --�� �, ".<s. , , - :e,�. � = >; Yip•,:.:.' 4;. X�: ax�J; F, iTy. � , ti�:."�7L ^ .. 5 +',"•o'.""+'. ==ti* m 0 g j C^ N ^17 to m m � vo co Q O O N•.< S. N h E D @ d � 3 S • To • - , 11) ~ m C' Or Q. [� o = • n Q m O O_Io 3 D Q' N a Ea a 3 • ' 61 O = 7 7 N m [ D Q N Q ° 11) -h o n m a 0 3 o m m 0 S' -8 SI a °- um a' � O CO '/' Qroam' E1 : : mom o to • — N DX ;[1 D D - /3 F El - 6` 3 m (D ;=r Q. las CD z O (D Q 12/24/2007 q:24:17 AM C 3 - 12GA THNN CONDUCTIONS (1 -HOT, 1 -NEU, 1 -GRD) TO 120 VAC NON - SWITCHED CIRCUIT LOCATED IN EXISTING LOAD CENTER BY T.C.E.C, (USE EXISTING CIRCUIT FROM OLD SYSTEM) J H F , In N CD 0 C) I" M - m ti CE ca v 0 G • O L.J O 0 0 D a r .1 LJ O (ENTRY WAY /STOCK PI is :z n (PUSH BUTTON OVERRIDE) (RETURN CO2) 0 (RETURN HUM%) ANEL BUILDER TO ATTACH EXTRA FUSE ND PUSH BUTTON OVERRIDE SWITCH ITN LABEL TO PANEL PERF. PLATE FOR SECURE SHIPMENT. 0• o 0 W I �' =1 1=1I Y1 F Z I W I YI ceI h 3 A 31 ,�I dzi I I I I I Ls L Lam— L _ L1 TI�BACK _ GRN IINP•„T FEVER 24 VA¢ 55 25J nA: RE S E.G. TO PULL 5 NEW 16GA THHN CONDUCTORS IN DEDICATED RACEWAY TO NEW GE LIGHTING PANEL (SEE DWG. EMS -7 FOR TERMINATION) fD > IAA )Ulf N H LJ lfld.L 3V z � J d Z W 1111 W AC INPUT H G N BLK GRN VHT 4 263(20 NEMA. ENCLOSURE L / r 1D /ICI; = "Ib0$ • E`HERN H i RAS1D1, ,:1 i 'j sE R • . I I 1 1 p, a8 1 1 -suea} I 0 CAT -5 CABLE TO STORE ROUTER. TO BE TERMINATED AT BOTH ENDS. (STRAIGHT THROUGHT CONNECTIONS) (LOW LEVEL LIGHTING) (HIGH LEVEL LIGHTING) ® I (SIGN $ DISPLAY LIGHTING) SPARE I I I I I I I I I I I I .L _L1_LJ r Ti 1 0 HLGH VOLTAGE X1 LOW VOLTAGE 2 osra 2 } ra , H. r 0 i I r I � - TO ENTRY WAY PIR. SEE EMS -I FOR LOCATION (PART it (CI -24) See EMS -8 - TO STOCK RM FIR. SEE EMS-1 FOR LOCATION (PART # (CI -24) SEE EMS -8 TO SPACE CO2 SENSOR. SEE EMS -1 FOR LOCATION (PART# CD -1W) SEE EMS-8 p TO SPACE HUMIDITY SENSOR. SEE EMS -I. (PART# AGI /R1-1-3 -R) SEE EMS -8 V›- TO NEW GE LIGHTING PANEL THIS AREA. SEE DRAWING EMS -7 FOR TERMINATIONS SEE EMS -8 ED- MOMENTARY PUSH BUTTON OVERRIDE SWITCH, SEE ABOVE (THIS DRAWING) FOR TERMINATIONS. 100 VA 100 VA H1 HIGH VO LTAGE XI LOV VOLTAGE 2 309 IF >— T2 vc) T ictp, 4fn RED BLK C I I L _ L, + A PUSH BUTTON OVERRIDE NFINET COMM. CABLE TO RTU -1: ( DO NOT RUN NEAR HIGH NOSE DEVISES NOR I N ANY CONDUIT W I TI-I LINE VOLTAGE !I) J E.G. TO MOUNT PUSH BUTTON OVERRIDE TO PANEL AND ATTACH BUTTON LABEL TO PANEL EXTERIOR 0 PANEL LEGEND FIELD WIRING #16GA. WIRE BY PANEL BUILDER #14GA. WIRE BY PANEL BU I LDER #16GA. WIRE BY E.C. #16GA. WIRE BY E.C. #14 GA. WIRE BY E.C. - PNEUMATIC TUBING #18GA. SINGLE PAIR NON - SHIELDED PLENUM GABLE BY E.G. #18GA. TWO PAIR NON - SHIELDED PLENUM CABLE BY E.G. 1$24 A. TWO PAIR IWI €LND - 1 X1 ® 6)(1-1)7 s JD 0 !SnX 0 5G O 10 X2 ®® 11 X2 ( INTERFACE PANEL AMERICAN EAGLE OUTFITTE � Southcenter Mall Tukwila, WA Spweft 2120 1 � KENNETH L. BUTTS, ARCHITECT Bell Cany CA 91307 .�$ 81 .999 -472 AMERICAN EAGLE OUTFITTERS 150 Them Hill Dr. - P.O. 788 W dale, Pe. 15095 (724) 776 -4857 :til.= .Fi, ".. --�� �, ".<s. , , - :e,�. � = >; Yip•,:.:.' 4;. X�: ax�J; F, iTy. � , ti�:."�7L ^ .. 5 +',"•o'.""+'. ==ti* m 0 g j C^ N ^17 to m m � vo co Q O O N•.< S. N h E D @ d � 3 S • To • - , 11) ~ m C' Or Q. [� o = • n Q m O O_Io 3 D Q' N a Ea a 3 • ' 61 O = 7 7 N m [ D Q N Q ° 11) -h o n m a 0 3 o m m 0 S' -8 SI a °- um a' � O CO '/' Qroam' E1 : : mom o to • — N DX ;[1 D D - /3 F El - 6` 3 m (D ;=r Q. las CD z O (D Q 12/24/2007 q:24:17 AM C 3 - 12GA THNN CONDUCTIONS (1 -HOT, 1 -NEU, 1 -GRD) TO 120 VAC NON - SWITCHED CIRCUIT LOCATED IN EXISTING LOAD CENTER BY T.C.E.C, (USE EXISTING CIRCUIT FROM OLD SYSTEM) J H F , In N CD 0 C) I" M - m ti CE ca v 0 G • O L.J O 0 0 D a r .1 LJ O (ENTRY WAY /STOCK PI is :z n (PUSH BUTTON OVERRIDE) (RETURN CO2) 0 (RETURN HUM%) ANEL BUILDER TO ATTACH EXTRA FUSE ND PUSH BUTTON OVERRIDE SWITCH ITN LABEL TO PANEL PERF. PLATE FOR SECURE SHIPMENT. 0• o 0 W I �' =1 1=1I Y1 F Z I W I YI ceI h 3 A 31 ,�I dzi I I I I I Ls L Lam— L _ L1 TI�BACK _ GRN IINP•„T FEVER 24 VA¢ 55 25J nA: RE S E.G. TO PULL 5 NEW 16GA THHN CONDUCTORS IN DEDICATED RACEWAY TO NEW GE LIGHTING PANEL (SEE DWG. EMS -7 FOR TERMINATION) fD > IAA )Ulf N H LJ lfld.L 3V z � J d Z W 1111 W AC INPUT H G N BLK GRN VHT 4 263(20 NEMA. ENCLOSURE L / r 1D /ICI; = "Ib0$ • E`HERN H i RAS1D1, ,:1 i 'j sE R • . I I 1 1 p, a8 1 1 -suea} I 0 CAT -5 CABLE TO STORE ROUTER. TO BE TERMINATED AT BOTH ENDS. (STRAIGHT THROUGHT CONNECTIONS) (LOW LEVEL LIGHTING) (HIGH LEVEL LIGHTING) ® I (SIGN $ DISPLAY LIGHTING) SPARE I I I I I I I I I I I I .L _L1_LJ r Ti 1 0 HLGH VOLTAGE X1 LOW VOLTAGE 2 osra 2 } ra , H. r 0 i I r I � - TO ENTRY WAY PIR. SEE EMS -I FOR LOCATION (PART it (CI -24) See EMS -8 - TO STOCK RM FIR. SEE EMS-1 FOR LOCATION (PART # (CI -24) SEE EMS -8 TO SPACE CO2 SENSOR. SEE EMS -1 FOR LOCATION (PART# CD -1W) SEE EMS-8 p TO SPACE HUMIDITY SENSOR. SEE EMS -I. (PART# AGI /R1-1-3 -R) SEE EMS -8 V›- TO NEW GE LIGHTING PANEL THIS AREA. SEE DRAWING EMS -7 FOR TERMINATIONS SEE EMS -8 ED- MOMENTARY PUSH BUTTON OVERRIDE SWITCH, SEE ABOVE (THIS DRAWING) FOR TERMINATIONS. 100 VA 100 VA H1 HIGH VO LTAGE XI LOV VOLTAGE 2 309 IF >— T2 vc) T ictp, 4fn RED BLK C I I L _ L, + A PUSH BUTTON OVERRIDE NFINET COMM. CABLE TO RTU -1: ( DO NOT RUN NEAR HIGH NOSE DEVISES NOR I N ANY CONDUIT W I TI-I LINE VOLTAGE !I) J E.G. TO MOUNT PUSH BUTTON OVERRIDE TO PANEL AND ATTACH BUTTON LABEL TO PANEL EXTERIOR 0 PANEL LEGEND FIELD WIRING #16GA. WIRE BY PANEL BUILDER #14GA. WIRE BY PANEL BU I LDER #16GA. WIRE BY E.C. #16GA. WIRE BY E.C. #14 GA. WIRE BY E.C. - PNEUMATIC TUBING #18GA. SINGLE PAIR NON - SHIELDED PLENUM GABLE BY E.G. #18GA. TWO PAIR NON - SHIELDED PLENUM CABLE BY E.G. 1$24 A. TWO PAIR IWI €LND - BACK VAV TAPE BACK GREEN EC TO MOUNT SPACE SENSOR 5' AFF. SEE DRAWING EMS -1 FOR LOCATION. INF. COMM. WIRE FROM PREVIOUS CONTROL DEVICE AS SPECIFIED BY EMS -1 AND EMS -2. SEE BELOW FOR TERMINATIONS ON VAV CONTROLLER. VAV -# SPACE TEMP AIR SAMPLE PORTS AIR FLOW - SENSOR SUPPLIED BY ROTP BROS. INC. - MOUNT SENSOR 5' A.F.F. ON OPPOSITE OF T1-1E SUPPLY DIFFUSER. - SEE DRAWING' EMS- -1 FOR LOCA I ON 24VAC POWER FROM FACTORY MOUNTED TRANSFORMER J INLET SIDE 0 INF. COMM. WIRE FROM r VAV -# SPACE TEMP F VAV CONTROL PANEL PREVIOUS CONTROL DEVICE. TAPE BACK GREEN 1 ! ( - VAV--# SUPPLY TEMP Questions? Please Call. See EMS Cover Sheet for Contact Info. INF. COMM. WIRE TO NEXT CONTROL DEVICE AS SPECIFIED BY EMS -1 AND EMS -2. SEE BELOW FOR TERMINATIONS ON VAV CONTROLLER. 1 I- F- 0_ cf.) 0 i71 <4_ N pal � 0 44-6 Vl X 751 f 4 Thawing No. E S34 SRLD YELLOW cRREN _ — Lr BLACK BLACK INF. COMM. WIRE TO NEXT CONTROL DEVICE. - ® - e LOW HIGH 0 0 - 0 —0 0 0 flo 0 0 2 3 5 N 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 L OI T3 OUT4 oUT5 GND OND RET SPWR INS REP - INI REP IN2 REP DT 1N4 - C# INF PORT 0A2A 10VA 50/60RZ DIGITAL omvurs 24VA0-1,0.5A SMART SENSOR UNIVERSAL INPUTS DAMPS RBSEP CPU IN OUT (AGM ( AIRFLOW MUT 12 865 MODEL SIN DATE n 865 DAMPER CONTROL ' OUTI /OLTI2 VAV BOX VAV VAV -# SUPPLY AIR TEMP 2 1/4 INCH POLY TUBES TO PROPER PORT ON AIR SAMPLE PORTS NOTE HIGH AND LOW PORTS!! I4-MI S �a OUTLET SIDE BELIMO Si•ned Wst Re/LI cOlt c N RECEIVED CITY OF TUKWILA FEB B 4 KO PERMIT CENTER Working Drawing Review gc Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- . to be kept on the job site at all times. - 1/3/08 Date !•1 cp m r 0 0 CY 0 1 _ o w Z Li - LO — cLzw (/)DIY I + I DI celAPci 0 I I 1 0 ,I! BACK VAV TAPE BACK GREEN EC TO MOUNT SPACE SENSOR 5' AFF. SEE DRAWING EMS -1 FOR LOCATION. INF. COMM. WIRE FROM PREVIOUS CONTROL DEVICE AS SPECIFIED BY EMS -1 AND EMS -2. SEE BELOW FOR TERMINATIONS ON VAV CONTROLLER. VAV -# SPACE TEMP AIR SAMPLE PORTS AIR FLOW - SENSOR SUPPLIED BY ROTP BROS. INC. - MOUNT SENSOR 5' A.F.F. ON OPPOSITE OF T1-1E SUPPLY DIFFUSER. - SEE DRAWING' EMS- -1 FOR LOCA I ON 24VAC POWER FROM FACTORY MOUNTED TRANSFORMER J INLET SIDE 0 INF. COMM. WIRE FROM r VAV -# SPACE TEMP F VAV CONTROL PANEL PREVIOUS CONTROL DEVICE. TAPE BACK GREEN 1 ! ( - VAV--# SUPPLY TEMP Questions? Please Call. See EMS Cover Sheet for Contact Info. INF. COMM. WIRE TO NEXT CONTROL DEVICE AS SPECIFIED BY EMS -1 AND EMS -2. SEE BELOW FOR TERMINATIONS ON VAV CONTROLLER. 1 I- F- 0_ cf.) 0 i71 <4_ N pal � 0 44-6 Vl X 751 f 4 Thawing No. E S34 SRLD YELLOW cRREN _ — Lr BLACK BLACK INF. COMM. WIRE TO NEXT CONTROL DEVICE. - ® - e LOW HIGH 0 0 - 0 —0 0 0 flo 0 0 2 3 5 N 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 L OI T3 OUT4 oUT5 GND OND RET SPWR INS REP - INI REP IN2 REP DT 1N4 - C# INF PORT 0A2A 10VA 50/60RZ DIGITAL omvurs 24VA0-1,0.5A SMART SENSOR UNIVERSAL INPUTS DAMPS RBSEP CPU IN OUT (AGM ( AIRFLOW MUT 12 865 MODEL SIN DATE n 865 DAMPER CONTROL ' OUTI /OLTI2 VAV BOX VAV VAV -# SUPPLY AIR TEMP 2 1/4 INCH POLY TUBES TO PROPER PORT ON AIR SAMPLE PORTS NOTE HIGH AND LOW PORTS!! I4-MI S �a OUTLET SIDE BELIMO Si•ned Wst Re/LI cOlt c N RECEIVED CITY OF TUKWILA FEB B 4 KO PERMIT CENTER Working Drawing Review gc Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- . to be kept on the job site at all times. - 1/3/08 Date !•1 cp m r 0 0 CY u , , ,, t ..,..,,, F .21 4 4 - •1. .,:. .. : .. . -3 1 .; LSI).4 rrt; fs: %1.00 ti 4 Li iLc Cifirk ; i .i. gi ri 1..t. . ,.: 5 t..... „.. L. r ral 0 4 44 gl ;•'.4 :.1 Irt a:I ti tt; .:4. e:t • VW "ei2 1 / ; g 2-r- 7,t• il 7 5 I C a) grE IIII; '1 t: 08:it■ ;I p.; 1 i C Z i I 2 111441 acS... ..„ .,, ..: itt3N ki '..1 ... ii .. • • - .7 . MI : • . °C) •:, ..•; •• t.-,,,t,i ME • Sitme4.) Drawing No. EMS.5 tam aanowarsemr 114101110111.611111111NM 1111 MEND REIM GOIMVIT MEL 0 0 ROM OffILINIBMW 1113111LEIMINW/L WIER AO NACIIIIIIML MIMED MIN 0 0 0 0 YF 011111181111111111ML ONENT1101111111111. CA Kiicemorannor 1011011111111.11111111MINFIs Main ifiRCOMMIL IBM= MIME _IWESPEIN• -479 FAN ENABLE : • • 1. • I . • HEAT-1 ENABLE 4 ■■()Rila■ ■■■ ■■■ ■■■ ■■■ HEAT-2 ENABLE 4 mi■ L L .11.■ - .■■ •■■• •■■■ •■■■ ■■■ ■■■ ME■11. ,■■■ 24VAC POWER FROM FACTORY MOUNTED TRANSFORMER 24VAC FROM FAN POWER SUPPLY 24VAC SWITCH LEG TO FAN TERMINAL STRIP 24VAC PROM HEATER POWER SUPPLY TERMINAL FI IN HEATER CONTROL SECTION. 24VAC SWITCH LEG TO HEATER TERMINAL STRIP STAGE-I 24VAC FROM HEATER POWER SUPPLY TERMINAL FI IN HEATER CONTROL SECTION. 24VAC SWITCH LEG TO HEATER TERMINAL STRIP STAGE-2 kWy ED VAV A 6141 rieV10 0 0 FU \DI CA 0 Questions? Please Coll. See EMS Cover Sheet for Contact Info. E.C. TO COORD 'ROPER E NEATER C0\7 E'TS SOLAT 0\ D7, VAV' BUM -- YBILQW TO ISOLATION RELAY COILS THIS DRAWING: LEFT SIDE). ATE IA1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 + - 2 - 3 SHRUM- 7 8 9 10 11 12 NL m otTrcul ours GND GND INFINET Pr 24VAC 0A2A, IOVA 5�Z DIGITAL OLTITUTS 24VAC-05A 13 14 13 RET 16 SPWR SMART SENSOR 17 INS mitm- 19 DI 1 20 RET 21 DI2 n 23 IN3 24 1N4 - UNIVERSAL INPUIS CTU IN OUT (HIGH) (LOW AIRVLOW MUT 12 865 MOM S/N DATE n 865 DAMPER CONIROL ourvour2 1 .c4 70 VE • 1•1 I4-MIS FY \ 0\S O\ FA\ A\D /OR OL TER' \ AL STS FS FRO'l REAY SA TD4 LEGS. D 0 • 53 BELIMO Wsifieid Working Drawing Review Approved Approved as Noted 0 Resubmit These drawings have been reviewed for general design intent only. Al! actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir • to be kept on the job site at all times. t 1/3/08 Si ned Date 1.1 RECEIVED CITY OF TUKWILA FEB C4/33 PERMIT CENTER L ti 0_ 1- t) 1 t.) uJ C0 LLJI USED TO CONTROL RELAY ON/OFF OR TO ADD/DELETE RELAY TO CHANNEL GROUP 115 NEUGND VAC TWO SEPARATE INPUTS FOR EACH CHANNEL. EACH WILL ACCOMMODATE EITHER 2-OR 3-WIRE, MAINTAINED OR MOMENTARY INPUTS. (SEE DWG. 1009) ISOLATED PILOT CONTACTS 1 AMP, 30VOLTS DC PILOT CONTACTS INDICATE CHANNEL STATUS. ALL RELAYS ON=CLOSED; OFF (g0®0®GOSOODS ®GOGO®E)0 (900E) 115 VOLT OR 277 VOLT AC (347V IN CANADA). TWO 40VA TRANSFORMERS WITH GE -MOV TRANSIENT PROTECTION. DEDICATED 120VAC/60/1 POWER FEED BY EC. 14 ■ 15 ■ 16 ■ 17 ■ 24 VOLT AC, 40VA FOR POWERING TIMECLOCKS OR OTHER CONTROLS. 24 VOLT RECTIFIED D FOR POWERING PILOT LIGHTS (CONNECTS TO PILOT RELAY COMMON). \ote: GE Panel " Consist of Anywhere Between 12 - 4E) Relays Depending on Job = fixture Sceledule Require rents. ( Exo'rple Above 5hoin for 24 Relay Panel). ACCESSORY DEVICE POWER TAP RR7P3 MECHANICALLY-LATCHING RELAY Working Drawing Review 4ic Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and /or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir- . to be kept on the job site at all times. 1/3/08 WslIle[it si • ned Date frNi 0 0 ('4 ANDOVER CONTINUUM xPBD4 GE CHANNEL LETTER FIXTURES CONTROLLED OS® 1 A Low Level Lighting /50% STOCK Area Lighting/50% fluting area 2 (Switch B) B Sales Area Track Lighting 3 C Sign and Display Window 4 D Spare 4 (Switch E) E 50% Stock Area Lighting ( ROLLING BROWNOUT) 4 (Switch F) F 50% Fitting Room Level (ROLLING BROWNOUT) In I in In in In in , ---- 0 OS® ®S clb® rS S ® ® ® ®SO,OOSO ®OS • -s 01 5OFTNIN ETAILS /SCHEDULES AMERICAN EAGLE OUTFITTERS Southcenter Mall Tukwila WA Space # 2120 am, +,'n.v....xu. r nn.*�.,i : S. 4:SI�ii�:T'"...I, :Ir•'tFn " +irr'T.., ;:i�,% ��..,.,;;!:`. �iT' r�: i�V�i: : „t?i�L'G:3S:5,'MC:irl,R:;:'K:: lei ... �,;;:�:-:.;,; 'i;:F” ., ..w- ,:4• -.'ux` .a. ":)L.;x:I«:'.� :'d« '� = �rrr.:v�:"'S:f�.:s .S:h.... ■ ' KENNETH L. BUTTS, ARCHITECT 124 Stagecoach sis��a n AMERICAN EAGLE OUTFITTERS 150 Thom Hill Dr. - P.O. 788 Wairoadale, Pa. 15095 (724) 776 -4857 . ,.., ..�.:., ::...;._. -.:�. r -�.. .., ,..... :: ,.:..,'..��. . �...: r - -:.: u.': :,..:..., .:..' .N.. ..f.. ,>•` . s.G:�. ?..e ��4�u�" r. i`+ ri. sici�i:'•: ri' s�= e; <kw.'.: ^i`ur.'�'.,,......�e. ;.i •�:2�. :=a:.:. ....- :7^:'�:..:.s. ru':a4� .. . ..� ., ; . ; i, �..:...,.... � _.. 3 m k:. :.4^ ;,. .. �. Fw wf:' iaaL. L::,`x:ht;.::!:.a.- .= , at..: d := .:�:.._ �.,..k,....:�,- ....w,w.,.c, s..m. r ... Y. r,..:....,. i.-..,. �.:. kC4�Hfus�x.. f.1 �.. ve..:. �.+} 1,.luv3lw.,h...14._.nGu.K�: {P�i �Y �i. xC.,...�. .. a- , ;S_:ivaa ,.. • °.r6:i' . i : ■ill;a:¢ u. ti'=: wF.'v:E " „:i4n`wxr.;g.74.,, a•rnl*�'r *l;C C arovi���'v w r h :.. 'S u.. �.. �w"”. �v'.: t:."-.: Ts•;:3 a7�.. �.: Ya, ��ad�`=. :w �l �. t.,...._,. .r.�i'.'„�Y,::;- _.,:_.;ti %.s:.,n :ic:: FIELD INSTALLED JUMPER. TYPICAL OF 6 (SIX) 7 - 16 GA TI -II-\ TO ANDOVER CONTINUUM (SEE EMS-3) ❑ ° N % 9J DD N ( o. cn z 0 m Q A — A • i i • A PRESS AND HOLD CHANNEL PUSH BUTTON FLASHING LED A 0 mi ROLLING BROWNOUT SWITCHES Three (3) SPST Switches for rolling Brownout,. SEE DRAWING EMS -I FOR LOCATION OF SWITCHES, See Andover /GE Wiring Interface Diagram Below For Switch Lee Terminations in GE Panel. FLASHING ' LED O cP G' r SWITCH " B 0 A A A A A A r <42> A C 0 3 "C" LEVEL SNITCH LOCATED OFF OF SALES FLOOR AREA Two (2) 16GA TFFN Conductors from Ltg Switch "C" to GE Panel "E" LEVEL SWITCH LOCATED IN STOCK ROOM Two (2) 16GA TFFN Conductors from Ltg Switch ' to GE Panel "F" LEVEL SWITCH LOCATED I N FITTING ROOM Two (2) 16GA TFFN Conductors from Ltg Switch "F" to GE Panel ANDOVER/GE WIRING INTERFACE i i ( T < / SWITCH fir e. 39 a SWITCH " e R B Y WR B Y W R B Y WR B Y W R B Y WR B Y WR B Y W LOW/50% STK 50% FITTING TRACK LTG. SIGN & WINDOW SPARE Sei STOCK RO 50% FITTING RM RBO ANDOVER/CONTACTOR WIRING INTERFACE SCHEDULE A i 0 A E 0 F 0 ♦ 4 SOFTWIR1NG A RELAY GROUP TO A CHANNEL A • N ON 1. PRESS AND HOLD THE CHANNEL PUSH BUTTON FOR SEVERAL SECONDS. THE CHANNEL LED AND THE LED'S FOR RELAYS CURRENTLY CONTROLLED BY THAT INPUT WILL BEGIN TO FLASH. 2. SELECT THE RELAYS TO BE CONTROLLED. THE LED FOR EACH RELAY "SOFTWI ED" TO THE CHANNEL INPUT SELECTED WILL BE FLASHING ON /OFF. PRESS THE ASSOCIATED RELAY CONTROL BUTTON TO ADD/DELETE THAT RELAY FROM THE GROUP. 3. PRESS THE CHANNEL PUSH BUTTON AGAIN. THE LED'S WILL STOP FLASHING AND THE INPUT SWITCH WILL NOW CONTROL THE RELAYS SELECTED. G 0 A • N OFF 4. TEST. PRESS THE CHANNEL PUSH BUTTON TO TOGGLE THE GROUP ON/OFF /ON. THE INPUT LED WILL TRACK THE LAST ACTION. NOW, TURN OFF EACH RELAY IN THE GROUP USING THE INDIVIDUAL RELAY CONTROL BUTTONS. WHEN THE LA T RELAY IS TURNED OFF, THE CHANNEL LED SHOULD ALSO GO OFF. GE PANEL CHANNEL INPUTS EMS -3) L� M A • ON RICAN ]EAGL3 OUT1FITTERS 12 2 200 q:29:3 S .. • ... ti- .._- _..�.._ ... �,.:�•i -ham RED ENTRY WAY PIR WIRING DEI'AILS O 24VAC OR +24VDC, +10% HOT RED 0 NORMALLY CLOSED CONTACT GRN COMMON ORN N7M 0 WHRE NORMALLY OPEN CONTACT YEL GREEN BLACK O 24VAC OR +24VDC RETURN BLK NUETRAL O 24VAC OR +24VDC, +10% NORMALLY CLOSED CONTACT COMMON NORMALLY OPEN CONTACT PIR INSTALLATION \ \ STOCK RM PIR WIRING DETAILS CEILING HOT RED GRN ORN YEL BLACK O 24VAC OR +24VDC RETURN BLK NUETRAL Rear housing Cover (with lens) 2-2/3' to 3' hole (If using 3' mud -ring, cut to accomodate) Ceiling attachment ring (bend behind ceiling to seam) Mask (optional) Cut for desired coverage DIP SWITCH SEI11NGS TYPICAL OF 2 (TWO) 2 SPACE HUMIDITY SENSOR DETAIL D > TYPICAL OF 1 (ONE) BLACK NUEIRAL,/I RED/HOT To via Va 0 4 SW2 c „,91 M 4M 3 2 SW3 SW3 4 1 3 1 2 1 1 1 CWE CO2 SENSOR TIDE COVER Red W1-4ITE 51aak 0 0 POWER. 024) coa COMMON CWE CO2 BACKPLATE 0 Signed Wsifleid 14 111■I imp (1317ne ` =Asp RE CITY OF TU FEB 0 4 ?fl 3 PERMIT CENTER Working Drawing Review Approved Approved as Noted ❑ Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is requir -. to be kept on the job site at all times. ( a , ,, 1/3/08 Date