Loading...
HomeMy WebLinkAboutPermit D08-069 - WESTFIELD SOUTHCENTER MALL - AERIE - STORAGE RACKSAERIE 2656 SOUTHCENTER MALL D08 -069 Citylif Tukwila Parcel No.: 6364200010 Address: 2656 SOUTHCENTER MALL TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: AERIE Address: 2656 SOUTHCENTER MALL , TUKWILA WA Owner: Narne: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA 90025 Phone: Contact Person: Name: SCOTT DAVES Address: 140 S LAKE AV, STE 323 , PASADENA WA 91101 Phone: 626 585 -2931 Contractor: Name: NATIONAL BUILDING CONTRACTORS Address: 1650 CARROLL AVE , SAINT PAUL MN 55104 Phone: 651- 222 -1859 Contractor License No: NATIOBC962RG DESCRIPTION OF WORK: INSTALLATION OF STORAGE RACKS doc: IBC -10/06 DEVELOPMENT PERMIT * *continued on next page ** • Permit Number: D08 -069 Issue Date: 04/14/2008 Permit Expires On: 10/11/2008 Expiration Date: 12/07/2008 Value of Construction: $0.00 Fees Collected: $180.23 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: IIB Occupancy per IBC: 0019 D08 -069 Printed: 04 -14 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City oikukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signature: Mn J Print Name: A't'AVS cglit T LP ( doc: IBC -10 /06 Permit Number: D08 -069 Issue Date: 04/14/2008 Permit Expires On: 10/11/2008 Date: V' I 1A5 I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • i , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performancc of wofk. am authorized to sign and obtain this development permit. Date: ( 1 -1 Y'' 0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -069 Printed: 04 -14 -2008 • City of Tukwila Parcel No.: 6364200010 Address: 2656 SOUTHCENTER MALL TUKW Suite No: Tenant: AERIE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS • Permit Number: D08 - 069 Status: ISSUED Applied Date: 02/05/2008 Issue Date: 04/14/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 12: Install mechanical stops between rolling shelving units so that when units are rolled together, a 6 inch flue space is maintained between shelving units to prevent sprinlder obstructions greater than 4 ft. wide. 13: All new sprinlder systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 14: Storage shall be maintained 2 feet or more below the ceiling in nonsprinldered areas of buildings or a minimum of 18 doc: Cond -10/06 D08 -069 Printed: 04 -14 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us inches below sprinkler head deflectors in sprinldered areas of buildings. (IFC 315.2.1) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila (206)575 -4407. * * continued on next page ** doc: Cond•10 /06 D08 -069 does not imply approval of Fire Prevention Bureau at Printed: 04 -14 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Arvve g‘A-I k-6 doc: Cond -10/06 D08 -069 Date: L - O9 ordinances governing or local laws regulating Printed: 04 -14 -2008 CITY OF TUKWS Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hlip: ! "iru'x'. ci. iukivila. a a. us [CONTACT PERSON — who do we contact when your permit is ready to be issued E Mail Address: f crn Q) a \. Coffin Company Name: 1 V C "T,nc. Mailing Address: 1 6S 0 Ccic--011 A Contact Person: g,11 C o t c o r n Company Name: Mailing Address: f en n erg L, L. R.45, A L.; L4- 1 �► ���� a / 0ad Contact Person: Y r B LA5 E-Mail Address: net; A 0 a c e (PLIA Q:\ApphcasonsWonns -Appt¢ anon On t-inc\3 -2006 - Permit Appiiation.doc Revised: 9-2006 bh Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. • (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** [SITE LOCATION ;,�l., soub, ��,a,4, `` may 6 C AA Ail Ki Co Assessor's Tax No.: c "1�� 1 0 Site Address: n o o+ ce - w01 . T1,,� c,,,,; L WA `BSI % Suite Number: V Id0 Floor: Tenant Name: P cc; e S J New Tenant: ® Yes ❑ ..No Property Owners Name: r ...0 C r6,1YAA: ein Lac Mailing Address: 1 1(101 �i1sl.t►n rtvc) �-oc ltA y c es O 1oo as � State Zip Name: SCo# l laves " Prtfli 7 Day Telephone: 6 c4 SAS a�3 Mailing Address: (] �o �-� Ave. Ske 301 Paco CA ( MM0 I City / State Zip Fax Number: G 26/7�a -s7 -7 7 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) rENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record State Zip City Day Telephone: 6 l l (9.1)-(2- I $ $ 9 E -Mail Address: Fax Number: 6 S/ / '7 17- 0'1 3 Contractor Registration Number: Expiration Date [ ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record CA R13o7 City State Zip Day Telephone: ? I F- `IV - y d 7 a Fax Number: g - ¶77 - / a / Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1of6 p3UILDING PERMIT INFO1 TION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 9C00. Existing Building Valuation: $ Scope of Work (please provide detailed information): Sntia.. ' I4 yr u% �oi.� a 1ntU'ivf �fnar in^ tsak ibte> ec.k- Co✓VVfl (iv,\ S e Will there be new rack storage? ErYes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below P_ ANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes l 7 No If `yes ", explain: FIRE PROTECTIONIHAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 2( No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x I1 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: tAppliatimsWmms- Apdiations On Unell.2006 - Peimit Appticuioadoc Revised: 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor Llo Jg a g t Floor 3r Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck p3UILDING PERMIT INFO1 TION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 9C00. Existing Building Valuation: $ Scope of Work (please provide detailed information): Sntia.. ' I4 yr u% �oi.� a 1ntU'ivf �fnar in^ tsak ibte> ec.k- Co✓VVfl (iv,\ S e Will there be new rack storage? ErYes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below P_ ANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes l 7 No If `yes ", explain: FIRE PROTECTIONIHAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 2( No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x I1 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: tAppliatimsWmms- Apdiations On Unell.2006 - Peimit Appticuioadoc Revised: 9 -2006 bh Page 2 of 6 • [ D ate Application Accepted: • ]PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. )3uilding and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED Signature: Print Name: Ave Day Telephone: Mailing Address: I y o S , L Av Sot � a3 P aseJen., Q: Applicatiod\Porms- Application Oe Linc\3 -2006 - Permit Appiication.doc Revised: 9-2006 bh City • Date Application Expires: On 1 �I 0 ,7 ) Date: — 6 ) .5 -0 6h/?131 91/0 State Zip Staff Initials: Page 6 of 6 RECEIPT NO: R08 -01171 Initials: JEM User ID: 1165 Payee: NATIONAL BUILDING CONTRACTORS SET ID: 0325 SET TRANSACTIONS: Set Member Amount D08 - 050 2,397.50 D Q$.;,,,0 C_c913 111.00 EL08 -107 541.20 M08 -025 369.18 PG08 -028 176.00 TOTAL: 2,397.50 TRANSACTION LIST: Type Method Payment ACCOUNT ITEM LIST: Description Check 36981 BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE SET RECEIPT Description SET NAME: AERIE TOTAL: Account Code 000/322.100 000.322.101.00.0 000/322.100 000.322.103.00.0 000/386.904 TOTAL: Payment Date: 04/14/2008 Total Payment: 3,594.88 Amount 3,594.88 3,594.88 Current Pmts 2,499.50 541.20 369.18 176.00 9.00 3,594.88 n.,�• aprcx e.na RECEIPT NO: R08 -00314 Payee: PERMITS TODAY LLC SET TRANSACTIONS: Set Member Amount • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us D08 -050 1,555.78 D08 -069 69.23 EL08 -107 135.30 M08 -025 84.80 PGO8 -028 35.00 TOTAL: 1,880.11 SET RECEIPT Initials: JEM Payment Date: 02/05/2008 User ID: 1165 Total Payment: 1,880.11 SET ID: 0204 SET NAME: AERIE TRANSACTION LIST: Type Method Description Amount Payment Check 1811 1,880.11 TOTAL: 1,880.11 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000/322.100 .20 ELECTRICAL PLAN - NONRES 000.345.832.00.0 135.30 PLAN CHECK - NONRES 000/345.830 1,744.61 TOTAL: 1,880.11 8098 02/05 9710 TOTAL. 1880.11 Project: Type of Inspection: F� ,4 � \ rl Address: ,..26.5" /11,9// Date Called: Special Instructions: Date Wanted: 2z- Ue a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Pee PERMIT NO. (206)431 -3 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: / Inspecto Date: - 72 - O. 0 REINSPECTION FE REQUI ED. Prior to inspection, fee must be at 6300 Southcenter Bl d., Suite 100. Call to schedule reinspection. Re eipt No.: 'Date: Project: A e Le, Type of Inspection: Inspection: 10%1 Address: ' in g Lt. Date Called: Special Instructions: Date Wanted: ��]] .���a// a.m. p.m. Requester: Phone No: INSPECTION NO. , INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1,2 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ti IS Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 4 /< • Inspector 'Date: 7 / lq /af El $60.00 REINSPECTION FEE RQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: • 'Date: Eclipse Engineering, Inc. s t r u c t u r a l s o l u t i o n s FILE COPY r ., _ .,- " 9 r 9 - Structural Calculations Steel Storage Racks Pipp PC Manual Carriage with Retail Shelving for Pipp Mobile Storage Systems, Inc. Aerie Store #2751 Southcenter Mall - Space #2120 Tukwila, Washington Prepared For: American Eagle Outfitters 540 Keystone Warrendale, PA 15086 155 NE Revere Avenue Suite A Bend, OR 97701 Phone: (541) 389 -9659 Fax: (541) 312 -8708 www.eclipse- engineering.com Pflit RECEIVED CITY OF TUKWILA FEB Q 5 2008 PERMIT CENTER Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Store #2751 - Tukwila, WA Pipp Mobile STEEL STORAGE RACK DESIGN kips:= 1000•Ib 2003 IBC & 2006 IBC - 2208 & ACSE -7 - 9.6.2.9 II, plf := ft Design Vertical Steel Posts at Each Corner : Shelving Dimensions: Total Height of Shelving Unit - h := 10-ft Width of Shelving Unit - w := 4-ft Depth of Shelving Unit - d := 1.33.ft Number of Shelves - N := 8 Vertical Shelf Spacing - S := 16•in Shelving Loads: Maximum Live Load From Jeans (stacked 14 pairs tall and 3 wide): Weight of (1) Pair of Jeans - W := 1.40•Ib Weight of Jeans per shelf - Wti := 3.14•W Load in psf - Wti LL j :_ w•d Design Live Load on Shelf - LL := 11 .psf Dead Load on Shelf - DL := 1.0•psf Modulus of Elasticity of Steel - Steel Yield Stress - Physical Dimensions of Channel : Channel Width - out -to -out - Channel Depth - out -to -out - Radius at Corners - Channel Thickness - Channel Width - CL - to - CL - Channel Height - CL - to - CL - Radius of Gyration in x and y - Section Modulus in x and y - Moment of Inertia in x and y - Full Cross Sectional Area - Length of Unbraced Post - Effective Length Factor - E := 29000•ksi F 33.ksi psf :_ — lb ft lb Pcf ft3 — ksi := 1000- L in 2 W = 58.81b LL = 11.0526•psf Section Properties of 3/4" x 1 9/16" x 16 Gauge Steel Channel : b := 1.5625.in h := 0.75.in R := 0.188•in t := 0.0593•in 16 Gauge b b -0.5•t h h – t r, := 0.4982 • in S := 0.0614•in I := 0.0557 • in A := 0.2246 •in L := 16.in L := 16.in L 16.in K := 1.0 Ky := 1.0 K := 1.0 Rolf Armstrong, PE b = 1.5329•in h = 0.6907•in r •= 0.3239 • in • Sy := 0.0628•in I := 0.0236 . in 1 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Store #2751 - Tukwila, WA Rolf Armstrong, PE Section Properties Continued: Density of Steel - psteel := 490.pcf Weight of Post - W := psteel•A Vertical DL on Post - Pd := DL•w•.5d•N + W Vertical LL on Post - P := LL•w•.5.d•N Total Vertical Load on Post - P := P + P Find the Seismic Load using Full Design Live Load : ASCE -7 Seismic Design Procedure: Importance Factor - IE := 1.0 Determine S and S from maps - S := 1.348 S := .464 Determine the Site Class - Class D Determine F and F - F = 1.00 F, := 1.54 Determine S and SM1 _ SMS := Fa•Ss SM1 = Fv•Si S = 1.348 S 0.7146 Determine Sp and SDI _ Sps 3 •SMS SDI 3 •SM1 Sps = 0.8987 SDI = 0.4764 Structural System (Table 9.6.2.2) & Section 9.14.6.3 ASCE -7: 4. Steel Storage Racks Total Vertical LL Load on Shelf - Total Vertical DL Load on Shelf - Seismic Base Shear Factor - Shear Factor Boundaries - R := 4.0 R := R W LL•w•d W p Wd := DL.w.d + 4. N Seismic Analysis Procedure per ASCE -7 9.6.1.3: Average Roof Height - h := 35-ft Height of Rack Attachment - z := 16.ft For 1st or second floor 0.4.a p•SDS V := 1 + 2 — R h Ip Vtmin := 0.3•S Vtmax 1.6• Sps•I p Vt := if(V > Vtmax, Vtmax, Vt) V := if (V < Vtmin , Vtmin , Vt) S2 := 2 a := 2.5 W = 7.6426•Ib Pd = 28.92261b P = 234.081b P = 263.0026 • lb Cd := 3.5 I := 1.0 W = 58.521b Wd = 9.14131b V = 0.4301 Vtmin = 0.2696 Vtmax = 1.4379 V = 0.43 2 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Seismic Loads Continued : For ASD, Shear may be reduced - Seismic DL Base Shear - DL Force per Shelf : Seismic LL Base Shear - LL Force per Shelf : 0.67 * LL Force per Shelf : Force Distribution per ASCE -7 9.5.5.4: Operating Weight is one of Two Loading Conditions : Condition #1: Each Shelf Loaded to 67% of Live Weight Cumulative Heights of Shelves - H := .5.S + 1.5.S + 2.5.S + 3.5.S + 4.5•S + 5.5.S + 6.5.S + 7.5•S H = 42.67 ft Total Moment at Shelf Base - Vertical Distribution Factors for Each Shelf - Total Base Shear - Vtotai Vtd + 0.67 Alt! Store #2751 - Tukwila, WA Rolf Armstrong, PE vt Vp := - Fd Vp Wd •0.5.S + W C C 0.0156 Mt Wd•1.5.S + W C2 := C2 = 0.0469 Mt Wd .2.5•S + WI.0.67.2.5•S C3 := C3 = 0.0781 Mt Wd • 3.5.S + WI.0.67.3.5•S C4:— C4 = 0.1094 Mt Wd .4.5.S + W C5 := C5 = 0.1406 Mt Wd• 5.5.S + W C6 := C6 = 0.1719 Mt Vtd := V Vtl := V F Vp F1 := 0.67•V Vtotal = 118.821b F1 := C3•(Vtotal) F2 C2 F3 C3 F4 C4•(Vtotal) F5 C5•(Vtotal) F6 C6•(Vtotal) V P = 0.3072 Vtd = 22.471b Fd = 2.81 lb Vt! = 143.821b FI= 17.981b FI.67 = 12.04Ib M H•W H•0.67•Wl M 2062.9 ft- Ib F 1.861b F2 = 5.57Ib F3 = 9.281b F4= 131b F5 = 16.71 Ib F6 = 20.421b 3 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Force Distribution Continued : Wd -6.5.S + W C7 := C7 = 0.2031 Mt Wd • 7.5•S + W C8 :_ C1 + C2 + C3 + C4 + C5 + C6 + C7 + Cg = 1 Coefficients Should total 1.0 Condition #2: Top Shelf Only Loaded to 100% of Live Weight Total Moment at Base of Shelf - Total Base Shear - Ci Cga Mta M Wd •0.5.S+ 0•W Mta Wd .7.5.S+ W C8 = 0.2344 Cia = 0 Condition #1 Controls for Total Base Shear Column Design in Short Direction : Bending Stress on Column - Allowable Bending Stress - Fb := 0.6 - Fy Bending at the Base of Each Column is Adequate Store #2751 - Tukwila, WA Rolf Armstrong, PE F7 := C7'(Vtotal) F8 C8- (Vtotal) F7 = 24.141b F8 = 27.85 lb Mt := H•Wd + 7.5•S•WI Mta = 975.2ft-lb Vtotal2 := Vtd + Fl C8a = 0.7 F8a := C8a • (Vtotal2) By Inspection, Force Distribution for intermediate shelves without LL are negligible. 1 M := 1 - S -(V + V fbX := M 1 Vtotal2 = 40.44 Ib Fla := C1a•(Vtotal2) Fla = 0.25Ib F = 28.06Ib M 55.4277ft•Ib f = 10.8328 -ksi Fb = 19.8•ksi 4 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Store #2751 - Tukwila, WA Find Allowable Axial Load for Channel Column : Allowable Buckling Stresses - 7r 7r Qex.x Distance from Shear Center to CL of Web via X -axis p1009 Steel Structures Design Book - Distance From CL Web to Centroid - Distance From Shear Center to Centroid - Polar Radius of Gyration - Torsion Constant - p1009 Steel Structures Design Book Warping Constant - p1009 Steel Structures Design Book Shear Modulus - Oex.x = 277.5014 -ksi e := 0.649•in – 0.5•t X0 := X + e 2 2 2 r := r + T + x 3 := 3 .(2.1)1 + h•t t -b 3•b -t+ 2• CW 12 2-1-11 t 6•b•t+ h.t G := 11300.ksi 1 crt _ Ap•r 2 / (Kt•Lt) Xo 2 p:= 1 – — r F et := 2 [( uex + (TO – J((TeX+ cry - 4. "'TeX crt] Elastic Flexural Buckling Stress - Allowable Compressive Stress - Factor of Safety for Axial Comp. - F := if(Fet < 7 ex, Fet, (Tex) F,, := i F > F , F • 1 FY Fe 2 y 4•F f2 := 1.92 °ex.y t hc 2 bc 2 4•I K - L 2 r 7r G•J + Rolf Armstrong, PE °ex.y = 117.295 • ksi (Tex if(oex.x < Qex.y, Oex.x, oex.y) Oex = 117.295•ksi e = 0.2983 • in = 0.6193.in x 0.9177•in r 1.0933 -in 3 = 0.00027.in C = 0.00648 - in Q = 38.3245 • ksi 3 = 0.2954 F = 30.6723 • ksi F = 30.6723 -ksi F = 24.1239•ksi 5 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Find Effective Area - Determine the Effective Width of Flange - Flat width of Channel Flange - w := b - R - 0.5•t Flange Plate Buckling Coefficient - k := 0.43 Flange Slenderness Factor - Effective Flange Width - Determine Effective Width of Web - Flat width of Channel Web - Web Plate Buckling Coefficient - Web Slenderness Factor - Effective Web Width - Effective Column Area - Nominal Column Capacity - Allowable Column Capacity - Combined Stress: Store #2751 - Tukwila, WA Rolf Armstrong, PE wf = 1.3449•in 1.052 wf Fn Xf :_ t E Xf = 1.0494 jkf 0.22 1 pf 1- — pf = 0.7532 X f X f b := if(X > 0.673, pf•wf, wf) b = 1.0129•in w h- 2•R -t w 0.3147•in k := 4.0 1.052 ww Fn X E E Xw = 0.0805 kw 0.22 1 Pw 1 — p = - 21.5197 Xw Xw h := if(X > 0.673, p w h = 0.3147.in A := t•(h + 2. b A = 0.1388.in P := A P = 33481b P P :_ P = 1744 lb Check Combined Stresses - 'Tr 2 •E•Ix 7C 2 •E.Iy Pcrx := Pal( 6 x 10 4 Ib P cry := r Kx•Lx lZ ( KY' / 1 Pcr := 1 f(Pcrx < Pcry, Pcrx, Pcry) Pcr = 26386 lb et Magnification Factor - �o Pp := 1 - a = 0.9809 Cm := 0.85 Pcr Pp + Cm fbx - 0.6249 P Fb Final Design: 3/4" x 1 9/16" x 16ga CHANNEL IS ADEQUATE FOR REQD COMBINED AXIAL AND BENDING LOADS P cry = 26386 Ib MUST BE LESS THAN 1.0 NOTE: P is the total vertical load on post, not 67% live load, so the design is conservative 6 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Store #2751 - Tukwila, WA Rolf Armstrong, PE STEEL STORAGE RACK DESIGN PER 2003 IBC & 2006 IBC - 2208 & ASCE -7 SECTION 9.6.2.9 Find Overturning Forces : Total Height of Shelving Unit - H := 10.ft Depth of Shelving Unit - d := 1.333•ft Number of Shelves - N := 8 Height to Top Shelf Center of G - htop Ht Height to Shelf Center of G - he (N + 1) S 2 From Vertical Distribution of Seismic Force previously calculated Controlling Load Cases - Weight of Rack and 67% of LL - W :_ (W + 0.67•4N Seismic Rack and 67% of LL - V := Vtd + 0.67•Vti M := F1.0.5•S + F2.1.5•S + F + F + F + F + Overturning Rack and 67% of LL - Weight of Rack and 100% Top Shelf - W := W • N + W Seismic Rack and 100% Top Shelf - V := Vtd + F Overturning Rack and 100% Top Shelf - M := Vtd•h + Fi•htop Width of Shelving Unit - w := 4-ft Vertical Shelf Spacing - S := 16-in h top = 10 ft ti = 6•ft W = 386.7978Ib V = 118.82321b F + F8.7.5•S M = 841.7ft•Ib W = 131.65061b V = 40.44271b M = 314.6ft•Ib W = 386.7981b V = 118.8231b M = 841.66ft•Ib Controlling Weight - Vi := if(W > W W, W Controlling Shear - V := if(V > V V, V Controlling Moment - M := if(M > M M , M Tension Force on Column Anchor - T := Mot — 0.90. Wc T = 457.35 Ib per side of shelving unit d 2 T:= if(T < 0•Ib, 0•Ib,T) T = 457.3472Ib V Shear Force on Column Anchor - V :_ � 2 V = 59.41b USE: HILTI KWIK BOLT II ANCHOR (or equivalent) - USE 3/8"4) x 2 1/2" embed installed per the requirements of Hilti Allowable Tension Force - T := 605•Ib For 3000psi Concrete Allowable Shear Force - V 1100•Ib 5 5 1 3 3 Combined Loading - r Ta + 1. Va a = 0.983 MUST BE LESS THAN 1.33 Ta NOTE: Anchors shall be embedded 8 *diameter to not be considered a shallow anchor. For 3/8" (I) anchor, use minimum 3" embedment 7 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Strap Bracing on Backside of Shelving Units : Total Seismic Base Shear - Shear Force on Backside into Braces - Store #2751 - Tukwila, WA Rolf Armstrong, PE V = 118.8232Ib V Vb . 2 Number of Shelf Bays Supported by Brace - Nb := 1 Each Shelf is Individually Braced 2 V b h c 2 Tension Force into Brace - Tb := Nb• Vb + Tb = 107.10581b w USE 1.0" x 14ga STRAPS Width of Strap - b := 1 • in Thickness of Strap - i : = 0.0747•in Area of Strap - A := b Tb Stress in Strap - ft := b A Allowable Tension Stress - F := 0.6.33•ksi USE #10 SCREWS or RIVETS TO CONNECT STRAP TO FRAME : Shear Capacity of #10 Screw - V := 293•Ib Connecting to 16ga metal Number of Screws Required - Shear Force from Brace - (Horizontal Component) Combined Loading - Tb Ns: Vc Tension Force from Brace - T„ := N (Vertical Component) w Vh Nb•Vb 5 5 [ 1.3.T v ) 3 ( 1.3.VhJ 3 + = 0.08 T V Vb = 59.41161b A = 0.0747 • i n f = 1.43.ksi F = 19.8.ksi N = 0.3655 USE: min (1) #10 SCREWS or RIVETS AT EACH END OF STRAP VERIFY HILTI BOLT CONNECTION FROM STRAP : h T = 89.121b Vh = 59.41161b MUST BE LESS THAN 1.33 8 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Store #2751 - Tukwila, WA STEEL ANIT -TIP CLIP AND ANTI -TIP TRACK DESIGN Tension (Uplift) Force on each side - T = 457.34721 Ib Connection from Shelf to Anti -Tip track: Capacity of 1/4" diameter bolt in 16 ga steel - Z := 312•Ib if(T < 2 .Z , "(2) 1/4" Bolts are Adequate" , "No Good ") = "(2) 1/4" Bolts are Adequate" Use 3/16" Diameter anti -tip device Yield Stress of Angle Steel - Thickness of Anti -tip Head - Width of Anti -tip Rod + Radius - Width of Anti -tip Head - Width of Anti -tip Flange - Tension Force per Flange leg - Bending Moment on Leg - Section Modulus of Leg - Bending Stress on Leg - Ratio of Allowable Loads - Width of Anti -Tip track - Thickness of Aluminum Track - Spacing of Bolts - Section Modulus of Track - Design Moment on Track - for continuous track section Bending Stress on Track - Allowable Stress of Aluminum Fy := 36•ksi t := 0.090 -in b := 0.25•in b := 0.490•in b — b L :— 2 T 0.5•T TI•La M := 2 b a• t a 2 SI • 6 M I fb S I f = 0.9602 0.6. L:= 5.1•in t 0.25-in S := 13-in L.tt St: 6 T•Stb M := 8 M f b . _ St Fb := 21 • ksi e L = 0.12.in T 228.67361b M 1.143368•ft•Ib S = 0.0007•in f = 20.7414.ksi MUST BE LESS THAN 1.33 Average Thickness Rolf Armstrong, PE S = 0.0531 • in M = 61.9ft•Ib f = 13.9894•ksi ANTI - CLIP STEEL CONNECTION AND TRACK ARE ADEQUATE note: since anti -tip bolts are in line with anchors, no prying action is required. Since the track is continuous with anchors @ 13" o.c., assume that a minimum (2) anchors will resist the uplift action because the stiffness of the track is adequate to distribute the Toad. 9 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers STEEL STORAGE RACK DESIGN STEEL CHANNEL SECTION PROPERTIES W/O LIPS Channel Dimensions 3/4 x 1 9/16 x 16 gauge - Channel Flange Length - d = 1.5625.in Channel Web Width - b := 0.75.in Channel Thickness - t := 0.0598•in Radius at Corners - R := 0.188•in Area of one Flange - Af := (df - t) •t Area of Web - Total Area of Channel - X-X Section Properties: Distance to Flange CL - Distance to Web CL Centroid of Channel - Dist - Flange CL to Centroid - Dist - Web CL to Centroid - Using Parallel Axis Theorem - Store #2751 - Tukwila, WA Rolf Armstrong, PE A := b •t A := 2.A + A d - t Yrx:= t+ 2 t Ywx 2 2- Af•Yfx+ Aw•Ywx Yc = 2 • Af + A Yx1 Yfx — Yc Yx2 Yc — Ywx t(df -t) Moment of Inertia of one Flange If 12 bw.t Moment of Inertia of Web - Iwx :_ 12 Af = 0.0899•in A = 0.0448•in A 0.2246•in yfx= 0 . 8111 •in Ywx = 0.0299 -in y = 0.6551•in Yx1 = 0.156 -in yx2 = 0.6252 -in Ifx = 0.0169•in I = 1.3365 x 10 5 • in Moment of Inertia of Channel - I := 2 -(I + A + (I + A I = 0.0557•in Distance from Centroid to edge - c := if(y > df - Yc, Yc df - Yc) c = 0.9074.in I Section Modulus of Channel - S := X S = 0.0614•in cx I Radius of Gyration - r := A r = 0.4982.in t 10 Eclipse Engineering, Inc. Aerie 12/31/2007 Consulting Engineers Y - Y Section Properties : t Distance to Outer Flange CL - xft := bw – 2 Store #2751 - Tukwila, WA Rolf Armstrong, PE xf1 = 0.7201•in Distance to Near Flange CL - x := 2 x = 0.0299.in Centroid of Channel - := - x = 0.375.in Dist - Flanges to Centroid - x x – x x 0.3451.in Moment of Inertia of Flange - IN :_ ( – t) t3 12 t b Moment of Inertia of Web - I := I = 0.0021 •in 12 Using Parallel Axis Theorem - t Ify = 0.000027 •in Moment of Inertia of Channel - Iy := Iwy + 2 • (If + A •x Iy = 0.0236 .in b w Distance from Centroid to edge - c •:= 2 c = 0.375 in Section Modulus of Channel - S := Iy S = 0.0628•in c Radius of Gyration - r := J — = 0.3239•in At 11 Aerie Store #2751 Date and Time: 12/31/2007 10:37:54 AM MCE Ground Motion - Conterminous 48 States Latitude = 47.4590, Longitude = - 122.2587 Period MCE Sa (sec) ( %g) 0.2 134.8 MCE Value of Ss, Site Class B 1.0 046.4 MCE Value of S1, Site Class B Spectral Parameters for Site Class D 0.2 134.8 Sa = FaSs, Fa = 1.00 1.0 071.5 Sa = FvS1, Fv = 1.54 Spectrum for Site Class D Period MCE Sa (sec) ( %g) 0.000 053.9 T = 0.0, Sa = 0.4FaSs 0.106 134.8 T = To, Sa = FaSs 0.200 134.8 T = 0.2, Sa = FaSs 0.530 134.8 T = Ts, Sa = FaSs 0.600 119.1 0.700 102.1 0.800 089.3 0.900 079.4 1.000 071.5 T = 1.0, Sa = FvS 1 1.100 065.0 1.200 059.6 1.300 055.0 1.400 051.1 1.500 047.6 1.600 044.7 1.700 042.0 1.800 039.7 1.900 037.6 2.000 035.7 ANCHOR DIAMETER (inch) ANCHOR DEPTH (ice) P ,, = 2,000 psi P,,= 3,000 psi P,= 4,000 psi P, = 6,000 psi Tension Shear Tension Shear Tension Shear Tension Shear With Sp. insp. Without Sp. Insp. With Sp. Insp. Without Sp. Insp. With Sp. insp. Without Sp. Insp. With Sp. Insp. Without Sp. Insp. 1 / 4 1 245 120 400 300 150 400 350 175 400 430 215 400 2 525 265 400 550 280 400 590 295 400 625 315 400 3 625 315 400 625 315 400 625 315 400 625 315 400 3 /8 1543 500 250 925 605 300 975 710 355 1,025 800 400 1,025 21/2 1,125 565 1,100 1,210 605 1,100 1,290 645 1,100 1,450 725 1,100 4'/ 1,190 595 1,100 1,235 615 1,100 1,285 640 1,100 1,450 725 1,100 1 / 2 2'/ 860 430 1,810 960 480 1,840 1,065 530 1,840 1,625 815 1,840 31/2 1,750 875 1,840 2,000 1,000 1,840 2,250 1,125 1,840 2,625 1.315 1,840 6 1,950 975 1,840 2,165 1,080 1,840 2,375 1,190 1,840 2,265 1,315 1,840 5 / 8 2 1,425 710 2,875 1,685 845 2,875 1,950 975 2,875 2,500 1,250 2,875 4 2,180 1,125 3,125 2,670 1,335 3,125 3,090 1,545 3,125 3,925 1,965 3,125 7 3,000 1,500 3,125 3,250 1,625 3,125 3,500 1,750 3,125 3,925 1,965 3,125 3 /4 33/4 1,850 925 3,875 2,175 1,090 3,875 2,500 1,250 3,875 3,000 1,500 3,875 4 2,750 1,375 4,225 3,625 1,940 4,225 4,500 2,250 4,225 5,060 2,530 4,225 8 3,750 1,875 4.225 4,625 2,315 4,225 5.500 2,750 4,225 5,925 2,965 4,225 1 41/2 2,930 1,465 6,625 3.650 1,825 7,125 4.375 2,190 7,625 4,360 2,180 8,625 6 3,990 1,995 8,625 5,310 2,655 8,825 6,625 3,315 8,625 7,875 3,940 8,625 9 6,040 3,020 8,625 7,050 3,525 8,625 8,055 4,025 8,625 10,000 5,000 8,625 Page 4 of 7 TABLE 3- CARBON STEEL KWIK BOLT II ALLOWABLE TENSION AND SHEAR VALUES IN NORMAL - WEIGHT CONCRETE )in pounds)' ESR -1355 or S I: 1 in = 2 5. 4 mm, 1 psi = 6. Id' a, 1 Ibl. = 'Table 2 describes spacing and edge distance requirements. 2 Except as noted in footnote 3, allowable loads may be adjusted in accordance with Section 5.5 of this report due to wind or seismic loads. 3 Ony the long - threaded style KB II anchor installed at this embedment depth is permitted to be used to resist shear due to wind or seismic forces. Long threaded style KB 1I anchors have a thread length greater than three bolt diameters. • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -069 DATE: 02 -05 -08 PROJECT NAME: AERIE SITE ADDRESS: 2656 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 2 � -/ -0 Bi D ivision Fire Prevention Y. Planning Division Comments: Ar:pi rived Notation: Docu; i IJrnWing slip doc 2 -2M -:' Public Works Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ n Permit Coordinator DUE DATE: 02-07 -08 Not Applicable n Per.- ;i_ Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route F Structural Review Required REV!EWER'S INITIALS: AV 1 OVALS OR CORRECTIONS: REVIEWER'S INITIALS: C No further Review Required DATE: DUE DATE: 03-06-08 Approved with Conditions Not Approved (attach comments) n DATE: Pe: :it Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License NATIOBC962RG Licensee Name NATIONAL BUILDING CONTRACTORS Licensee Type CONSTRUCTION CONTRACTOR UBI 601990646 Ind. Ins. Account Id #4 Business Type INDIVIDUAL Address 1 1650 CARROLL AVE Address 2 City SAINT PAUL County OUT OF STATE State MN Zip 55104 Phone 6512221859 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/7/2004 Expiration Date 12/7/2008 Suspend Date Separation Date Parent Company Previous License NBCGECI011QC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date CORCORAN, WILLIAM B OWNER 12/07/2004 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #4 BANCINSURE INC BIWA24216A 11/01/2005 Until Cancelled $12,000.00 12/02/2005 #3 BANCINSURE INC BIWA22928A 11/01/2004 Until Cancelled 11/01/2005 $12,000.00 11/15/2004 Look Up a Contractor, Electri. or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= NATIOBC962RG 04/14/2008 / I '-'" ICI SQ. FT. --- S -" ICI SALES AREA 3, 040 I s -L..4 ICI Tr 5 5 5 284 a Ci ■_.... 'INI. all 141 SQUARE FOOTAGE AREA SQ. FT. % SALES AREA 3, 040 75 FITTING ROOMS 455 11 STOCK ROOM 284 TOILET ROOM (S ) 63 2 EXIT CORRIDOR 141 5 COMPUTER CLOSET cl3 2 TOTAL 4, 059 100% 4'-O" x 2-O SENCW FURN. BY TENANT, INST. BY G.C. SEE DETAILS ON SHEET A.2.q' ANTI -TIP BRACKET FOR STOCK SHELVING FURNISHED BY TENANT, INSTALLED BY G.C. STOCK SHELVING (MO FIXED) FURN. BY INSTALLED BY DETAILS F/F.0.2, 14/F.O. ILE AND ENANT, .C. SEE /F.0.2 t (TYP.) —INDIVIDUAL COAT HOOKS (TYP.) SEE DETAIL E/A.2.9 lot-o-Ru • . • . • • • • . . • . • tiTCE: ALL SHELVING SHALL BE 10 A.F.F. - • 5' X 5' OVAL POUF. FURNISHED BY TENANT INST BY G.C. 1:7= =-11 t4ganW=hUlerM. r -0 • DETALs oN %MET (rrP.) 1 . • • PEGBOARD PANEL - FURN. BY TENANT, INST. BY G.C. (INSTALL PER CUT-OUTS FOR SHELVING HANDLES) PEGBOARD PANEL- FURN. BY TENANT, INST. BY G.C. SEE DETAIL A/F.O.I (TYP.) 25 VANITY FURNISHED BY TENANT, PLACED 5Y OVAL MIRROR FURNISHED BY TENANT, PLACED SY G.C. ta3a=z&,wA 3-NAY MIRROR 4 PREFAB. "ANGLED" WALL ASSEMBLY. ///////././//./7././,/ --412021=====:072=02= r 0 IC 15" DIA. FITTING ROOM POUF, FURN. BY TENANT, PLACED BY G.C. (TYP. OF 2 PER ROOM ) CONTINUOUS CURTAIN ROD - MOUNTED. 141/ 13RACKETS TO FACE oF FITTING ROOM HEADERS/TRIM FURN. INST. BY G.C. (TYP. OF 2) LADDER I-IANG BRACKET FURN. BY TENANT, INST. 5Y G.C. 4111 86" -BB" A.F.F. (TYP OF 2) SCALE: 1/4" 1 NO. > —■—•11111111 PEGBOARD PANELS FURN. BY MILLWORK SUPPLIER INSTALLED BY G.C. SEE FLOOR PLAN FOR LOCATIONS FLOOR 15(ISTING WALL SURFACE PEGBOARD DETAIL (ELEVATION) !P,k_fig 1E7.4C kt+P°1k.Y tFNANT AA)Al2.6 "v1P'f:Ci 27' — HANG BAR STORAGE CABINET FURN. BY TENANT INST. 5Y G.C. DI EMPLOYEE LOCKERS FURN. BY TENANT INST. BY G.C. (TYP) COMPUTER CABINET - FURN. 13Y TENANT, INST. BY G.C. SEE DETAIL A/E.0.2 AND CABINET ISOMETRIC DETAIL A/F.0.2 30-0- SURFACE MOUNTED I X 5 FLOOR SLEEPERS FURN. BY FLOORING SUPPLIER INST. BY G.C. CONTINUOUS di TOP, MIDDLE AND BOTTOM OF PEGBOARD 1 COTR 111/10NddV OR 11 NO- (111SST r SCALE: 1/41" 1' - O q2 7 • t 'ORS \):/ t 1 „El:S( I F25a' FOR / G.C. SHALL FURNISH AND INSTALL 3/4"x4x4 NON-COM PLYWOOD BACKER BOARD AT 6'-O' ABOVE CONCRETE SLAB. TO BOTTOM FOR AUD1ONISUAL SYSTEM BY AUDIONISUAL CONSULTANT. SEE DETAIL A/E.0.2 AND CABINET ISOMETRIC DETAIL A/F.0.2. 107 FIXTURE PLAN n •t7 7 -7 L PREFAB. "BACK WRAP" COMPONENTS. SEE SHEET 'F.2.2' FOR MORE INFORMATION. DV' 11 ;• 1 PREFABRICATED "LEANING" MIRROR FURN. BY TENANT, INST. BY G.C. (SIM TO PET. E/F-4 4 F/F-4) (TYP OF 2) 22 1 1 . ,, - ,--'- C L.,' ,.. ;:" - - k-....* - I; '..—..±,.- t .1 1 9 • 1. BY t FILE COPY Permit No. Mar review approval Is subject to errors and omission! Approval of consbuclion documents does not authoriz the violation of any adopted code or ordinance. Reoalf of approved Field Copy and r acknsvdedge De - ro City of Tukwila BUILDING DIVISION scpe .0 to changes ,„,.__,,„_:.„ ,::,_,......._________:;,...:..„ th ,,,, ri __,_,„ T ____ y !---',." ,1;6,i; °I wTcurkkwl-IlleallBuctsitc.ilncgrE7‘.;:irovrta.1 ot NO'rE: Revisions wi11 require a new plan submittal and may include additional plan review lees. RECEIVED CM OF TUKVVILA FEB 65 2008 PERMIT CENTER P0 0(01 1 , • Drawing No. 751 F.0.1 12/24/2007 q:06:47 AM TYPE SIZE CAPACITY C 36" X 16" DOUBLE BAR W/ 6 SHELVES C1 48" X 16" DOUBLE BAR W/ 6 SHELVES D 36" X 16" SINGLE BAR W/ 8 SHELVES DI 48" X 16" SINGLE BAR N/ 8 SHELVES TYPE SIZE MC -1 32 1/4" X 37 MC -2 32 1/4" X 49" MC -3 32 1/4" X 75" MC-4 32 1/4" X 85" MC -5 32 1/4" X97" 3/4" X 3/4" NON -COM PLYWOOD BACKER BOARD AT 6' -0" ABOVE CONCRETE SLAB. - BY G.G. AUDIONISUAL SYSTEM BY AUDI ON ISUAL CONSULTANT MOUNTED 6' -3" ABOVE CONCRETE SLAB. 2 X 4 NON - COMBUSTIBLE WOOD CLEATS (TOP AND BOTTOM) BY G.C. G.C. SHALL SECURELY FASTEN COMPUTER CABINET TO CLEATS. PREFABRICATED COMPUTER CABINET FURNISHED BY TENANT, INSTALLED BY G.C. 1/4" X 2 DRIVE ANCHORS SPLICE TRACK ANCHOR AT END AND AT SPLICE- (2)/TRACK STAGGER TRACK SPLICE + INSERT SPLICE. CO1 1z CABINET NITS A/V SYSTEM ISOMETRIC ` -, NO SCALE SINGLE PIECE TRACKS ANCI-IOR ONLY AT ENDS_ MOBILE CARRIAGE UNIT END 570P DETAIL NO SCALE • ANCHOR STOP TO FLOOR W/(2) 1 /4" X 2" HAMMER DRIVES. v eyV (u 1 1 Ii(J -1 QRf1SST )f1- 1 77 -7L FIXED SHELVING UNIT - MOBILE SHELVING UNIT SHELF UNIT KEY MOBILE CARRIAGE UNIT MOBILE CARRIAGE UNIT KEY EXISTING / RELOCATED FIXED SHELVING UNIT 3 A A MC -6 A A EXAMPLE: NOTE: SHELF INSTALLATION INSTRUCTIONS AND DIMENSIONS ARE TYPICAL FOR A SHELF HEIGHT OF 120 ". SEE SHEET 'F -1' FOR ACTUALL SHELVING HEIGHTS AND ADJUST SHELVING INSTALLATION ACCORDINGLY. NO SCALE 1_ ry• t\ VI, 1 1•.►'pVt% 1\1 1 T STOCK THE ANTI -TIP ANGLE FACING TOWARDS ISTEP I WALL. PLACE Z -RAIL OVER THE ANTI -TIP ANGLE WITH A MAXIMUM CLEARANCE OF 1/2" BETWEEN PIECES AS SHOWN. 1/8" X 1" X I" X 3" LONG STEEL ANTI- TIP ANGLE WELDED TO MOVING TRAY STEP #1 120 PLACE PERIMETER TRACK 014 FLOOR WITH A MINIMUM DISTANCE OF 2 1/2" BETWEEN EDGE OF TRACK AND WALL/FIXED SHELF. (ANCHOR WITH 1/4" X 2" HAMMER DRIVES) L. C SERI ES Z" MAX CARRIAGE SECTION ANTI-TIF DETAIL HANG BAR SEE NOTE #5 SEE NOTE 4t-4 'SEE NOTE #8 SEE NOTE #6 SHELVING DETAIL 1/8" X 1 X 2 -1/4" i" STEEL Z -RAIL SECURED TO SLAB W/ 1/4 X 2" HAMMER DRIVE ANCI -IORS 1P 12" O.C. SCALE: 3" 1' - 0" SEE NOTE #6 `* WALL OR FIXED SHELF FLOOR SERIES SEE NOTE #6 HANG BAR SEE NOTE #5 SEE NOTE #4 'SEE NOTE #8 SEE NOTE #6 SHELF INSTALLATION NOTES 1. INSTALL TRACK PER MANUFACTURER'S INSTRUCTIONS. TRACK MUST 8E LEVEL (USING SHIMS AS REQ'D.) TO INSURE PROPER OPERATION. MAINTAIN 2" MINIMUM CLEARANCE BETWEEN EDGE OF TRACK AND WALL. 2. INSTALL SHELF UNITS ON MOBILE CARRIAGE. SHELF UNIT MUST BE SECURED TO UNDER CARRIAGE USING ONE TEK SCREW IN EACH CORNER. 5. INSTALL BRAKES ON ALL MOVEABLE CARRIAGES PER MANUFACTURER'S INSTRUCTIONS. 4. DOUBLE X BRACES ARE REQUIRED ON MOBILE UNITS ONLY. FIXED UNITS REQUIRE SINGLE 'X' BRACE. 5. INSTALL TWO BUMPERS BETWEEN EACH MOBILE UNIT 71 1/2" FROM BOTTOM IN PREDRILLLED HOLES. 6. THESE SHELVES TO BE PERMANENTLY FASTENED IN PLACE USING TWO TEK SCREWS AT EACH END THRU CROSS RAIL. 7_ ALL SAGO TO BACK SHELF UNITS MUST BE FASTENED TOGETHER USING AT LEAST FOUR TEK SCREWS PER VERTICAL UPRIGHT. 8. ATTACH HANDLE 44" A.F.F. +/- TO CENTER ON MOBILE UNITS ONLY. NOTE: CONTRACTOR TO CONSULT TENANT ONSITE CONSTRUCTION REPRESENTATIVE REGARDING PLACEMENT OF WARNING PLACARDS. NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE SEEN PURPOSELY OMITTE AND DO NOT PERTAIN TO 11H19 PROJECT. RECEIVED CITY OF TUKWILA FEB c.5 2008 PERMIT CENTER NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE SEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT.