Loading...
HomeMy WebLinkAboutPermit D08-073 - WESTFIELD SOUTHCENTER MALL - PAYLESS SHOESOURCE - SHELVINGPAYLESS SHOESOURCE 2866 SOUTHCENTER MALL D08 -073 Parcel No.: 6364200010 Address: 2866 SOUTHCENTER MALL TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Tenant: Name: PAYLESS SHOESOURCE Address: 2866 SOUTHCENTER MALL , TUKWILA WA CitAf Tukwila • Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA 90025 Phone: DEVELOPMENT PERMIT Contact Person: Name: CORNEL PURAVET - FREIHEIT & HO ARCHITECTS Address: 10230 NE POINTS DR SUITE 300 , KIRKLAND WA 98033 Phone: 425 - 827 -2100 Contractor: Name: BRUNDIGE FLOOR COVERING CO Address: 10203 W 125TH TERRACE , OVERLAND PARK KS 66213 Phone: Contractor License No: BRUNDFC9700N Permit Number: D08 -073 Issue Date: 05/27/2008 Permit Expires On: 11/23/2008 DESCRIPTION OF WORK: INSTALL INTERIOR DISPLAY SHELVING FOR SHOE DISPLAY SHELVING FOR SHOE DISPLAY AND STORAGE. MAXIMUM SHELVING HEIGHT IS 9' -2" Value of Construction: $0.00 Fees Collected: $388.13 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: II -B Occupancy per IBC: 0019 doc: IBC -10/06 * * continued on next page ** Expiration Date: 09/15/2009 D08 -073 Printed: 05-27 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: doc: IBC -10/06 City aftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us N Permit Number: DO8 - 073 Issue Date: 05/27/2008 Permit Expires On: 11/23/2008 Date: i [Z1 I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Date: Print Name: /,(.h�r, i ,^vr70Z- rz This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 - 073 Printed: 05-27 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: PAYLESS SHOESOURCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2866 SOUTHCENTER MALL TUKW PERMIT CONDITIONS 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. * *continued on next page ** • Permit Number: Status: Applied Date: Issue Date: D08 -073 ISSUED 02/05/2008 05/27/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. D08 -073 Printed: 05-27 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: GUP -7�i1h L �")-) GYi Date: ,. /.� /0., doc: Cond -10/06 D08 -073 Printed: 05-27 -2008 r SITE LOCATION CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd-, Suite 100 Tukwila, WA 98188 l�tJp:;;ht rcu .ci. tuk3a ila. Wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Site Address: 2 $66 oltiCE MALL Suite Number: 2165 Floor: 2 Tenant Name: PAY 55 SHue sov(LC New Tenant: if Yes ❑..No Property Owners Name: WEST ELb , LL Mailing Address: 11 6 01 VNIL SH712E 15LV1). II-1h FLooll CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Cm2NEL Pk/ v6 / Feei HE ITt I'tb Day Telephone: 0 21 2 Mailing Address: 12 NE POINTS D(ZIVE Sv1TE 3c0 1-1121 citos& City State Zip Fax Number: <425) 221 " 624tcr E -Mail Address: C pv rove{ ® F o c. rd..% , corn Building Permit No. i y) g- 07 3 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) City 2 o ANGELES, cA 4 100 0 25 State Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: -T-. 1.11. • Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Contact Person: ¶0 M 5 PAb f tZ E -Mail Address: t S pc de r °� f li rch . corn ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:\Applications\Forns- Applications On Linel3 -2006 - Permit Application.doc Revised: 9-2006 bh State City Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record FILE1NETT 8 11 Al2cNITFcTS tNG, P.S. Mailing Address: IO2. 3c NE. Pea N'1S big) vE, Ire 300_, k 1 RKLAN D, WA 6 1 3o$3 City State Zip Day Telephone: ( •21 -210 ( Fax Number: t25) $ 2 b- 6 1 94 1 Company Name: Mailing Address: City State Zip Page 1 of 6 Will there be new rack storage? Yes • • BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ ta 0 Existing Building Valuation: $ Scope of Work (please provide detailed information): I Al STALL I NTE 121 A2. bi S pc /4, S NCL. V / NU Po(L StibE Disvc■or y A Nb s 7INizA 66. Pvi.x 1V6 h7 iS at_2" ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: rt Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: yn Sprinklers xi Automatic Fire Alarm ❑ None N Other (specify) EXIT/ 'G SyS'Crt Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 'i No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: \Applications\Forrms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Existin . Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 663,727 2nd Floor 24 I 6 o3 �i 120 S O 11- t3 M rd Floor V'-{4O Floors thm Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Will there be new rack storage? Yes • • BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ ta 0 Existing Building Valuation: $ Scope of Work (please provide detailed information): I Al STALL I NTE 121 A2. bi S pc /4, S NCL. V / NU Po(L StibE Disvc■or y A Nb s 7INizA 66. Pvi.x 1V6 h7 iS at_2" ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: rt Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: yn Sprinklers xi Automatic Fire Alarm ❑ None N Other (specify) EXIT/ 'G SyS'Crt Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 'i No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: \Applications\Forrms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR CI( ZED ENT: Signature: Date: 2- ^ •° Print Name: Date Application Accepted: Col2.N EL Pu Rp VI T Day Telephone: 1 12 5 2 '2 Mailing Address: IO2 30 N E 9 75 Dl2i VE ' i'TE 3 K If - KIA'ND W/r ' o33 City 'State Zip Date Application Expires: 8 Q Wpplications\Forms- Applications On Line\3 -2006 - Permit Application :doe Revised: 9 -2006 bh Staff Initials: m e_ ,/f Page 6 of 6 Doc: RECSETS -06 RECEIPT NO: R08 -01803 Initials: WER User ID: 1655 Payee: BRUNDIGE FLOOR COVERING CO. SET ID: 0527A SET NAME: PAYLESS SHOES SET TRANSACTIONS: Set Member Amount D08 -072 1,922.50 D08-0;73 237.00 TOTAL: 2,159.50 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Description Payment Check 14987 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE SET RECEIPT TOTAL: Payment Date: 05/27/2008 Total Payment: 2,159.50 Amount 2,159.50 2,159.50 Account Code Current Pmts 000/322.100 2,150.50 000/386.904 9.00 TOTAL: 2,159.50 2875 05/27 9710 TOTAL 2159.50 Parcel No.: 6364200010 Permit Number: D08 -073 Address: 2866 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/05/2008 Applicant: PAYLESS SHOESOURCE Issue Date: Receipt No.: R08 - 00322 Initials: WER User ID: 1655 Payee: FREIHEIT & HO ARCHITECTS TRANSACTION LIST: Type Method Description Amount Payment Check 18520 151.13 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 . Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 151.13 Total: $151.13 0 Payment Amount: $151.13 Payment Date: 02/05/2008 02:53 PM Balance: $237.00 8103 02/05 9710 TOTAL 1695.83 doc: Receiot -06 Printed: 02 -05 -2008 Project: / /ASS SA0 Type of Inspection: L Address: l 2 4 Date Called: Special Instructions: Date Wanted: 7642 a.m. P• Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. Doe -67; CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 MI Approved per applicable codes. Corrections required prior to approval. COMMENTS: eeis (JsK Ft 44 id o(I_ Inspector: Date: 7 /44.6) $58.0 I NSPECTION FEE REQUIRED. Prior o inspection, fee must be paid 300 Southcenter Blvd.. Suite 100. Call the schedule reinspection Receipt No.: Date: . 5 �rrenM_,— °^sstnsifi4a.:.- .:n,saeomt� =kd•___ :�.._._ - CF.' k r°. �i��c !',a?a•rit"fir- t'.:tevle.7�;1iB • • FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 KIRKLAND, WA 98033 P:425.827.2100 F:425.828.6899 WWW.FHOARCH.COM February, 14, 2008 City of Tukwila 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 ATTN: Allen Johannessen RE: Letter of Incomplete Application #1 Development Permit Application: D08.073 Payless Shoesource — 2866 Southcenter Mall Mr. Johannessen: The following are listed in response to the Review Comments that we have received for the subject project from your department. The responses are listed in chronological order according to the Review Comments received February 8, 2008. 00 8-73 — permit response.doc 1. This response is to clarify the proposed conditions of the rack storage. The Payless shoe store will have rack storage within the main sales area over 5 feet 9 inches in height but will not exceed 8 feet in height. The maximum rack storage height will be at 6 feet 10 inches and therefore will not require engineering calculations. Per our phone conversation on February 11, it was clarified that the shelves in the office area are not considered as rack storage since they are mounted on and attached to the walls. Since all the rack storage for this project is less than 8 feet in height, we are not submitting structural calculations and will consider the rack storage application complete based on the above information. This is the end of our responses to the plan review comments. Please feel free to call me if you have any questions or comments regarding our responses. Thank you. Sincerely, FREIHEIT & HO ARCHITECTS, INC., P.S. Cornel Puravet Architectural Designer INCOMPLETE lTR #� tXB 0/ 3 FEB 15 2008 'titvu I CENTER r February 8, 2008 Cornel Puravet Freiheit and Ho Architects 10230 NE Points Drive, Suite 300 Kirkland, WA 98033 • City of Tukwila Department of Community Development Jack Pace, Director RE: Letter of Incomplete Application # 1 Development Permit Application D08 -073 Payless Shoesource — 2866 Southcenter Mall Dear Mr. Puravet, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on February 5, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator Enclosures File: D08 -072 114 P:\Permit Center\Incomplete Letters\2008\D08 -073 Incomplete Ltr # 1.DOC jem • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • Determination of Completeness Memo Date: February 7, 2008 Project Name: Payless Shoesource Permit #: D08 -073 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Storage racks that are more than 8 feet high shall require an engineered design or calculations. Please provide a design by a registered engineer that specifies hardware and methods for anchoring and bracing for the storage racks. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. ACTIVITY NUMBER: D08 -073 DATE: 02 -15 -08 PROJECT NAME: PAYLESS SHOESOURCE SITE ADDRESS: 2866 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS: B I. 1 g • 'vision 2 Public Works Complete Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP TUES/THURS ROUTING: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required n n Permit Coordinator DUE DATE: 02 -21-08 n No further Review Required DATE: DATE: Planning Division Not Applicable o p v I, n DUE DATE: 03 -20 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 1ERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -073 DATE: 02 -05 -08 PROJECT NAME: PAYLESS SHOESOURCE SITE ADDRESS: 2866 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: A f Buid�j g �IVlslon Public Works Complete Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: 5-' Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Coordinator n DUE DATE: 02 -07 -08 DATE: DATE: Planning Division Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: ' `-' � " Of) LETTER OF COMPLETENESS ILED: Departments determined incomplete: Bldg LJ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required n No further Review Required REVIEWER'S INITIALS: DUE DATE: 03 -06-08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us i RtVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 2- 14 -2oog Plan Check/Permit Number: DO8-073 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # - after Permit is Issued n Revision requested by a City Building Inspector or Plans Examiner Project Name: PAYLESS SHOESOURCE Project Address: 2866 Southcenter Mall Contact Person: Cornel Puravet Phone Number: ' 29 223 - 21 op Summary of Revision: No CNAN WE P AbE TO ¶1#E vro RAG E. 1 15 P a-0 se cr 14Afra RA Ck SrgaRAGE owe l2 a FEAT IN 1-EtGM A ND 5712.JCfu ILA L CALCiLArttoN$ ARE KIT KEQcdt Sheet Number(s): 1 /A "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms- applications on line \revision submittal Created: 8 -13 -2004 Revised: RECEIVED i iLL z LOC3 License Information License BRUNDFC9700N Licensee Name BRUNDIGE FLOOR COVERING CO Licensee Type CONSTRUCTION CONTRACTOR UBI 602326349 Ind. Ins. Account Id #1 Business Type INDIVIDUAL Address 1 10203 W 125TH TERRACE Address 2 City OVERLAND PARK County OUT OF STATE State KS Zip 66213 Phone 9136815187 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/15/2003 Expiration Date 9/15/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 HARTFORD FIRE INS CO 37BSBCL4210 09/01/2003 Until Cancelled $12,000.00 09/15/2003 Business Owner Information Name Role Effective Date Expiration Date BRUNDIGE, WELDON OWNER 09/15/2003 Look Up a Contractor, Electri n or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. I Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= BRUNDFC9700N 05/27/2008 STORE 43QTRL 2866 SQUTENTR VALL TU<NLA, AA ISSS SEPARATE PERMIT REQUIRED FOR: 4 Mechanical Cr Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION ING Nt7EX REVISIONS __ No changes shall be made to the sc of work without prior approval of Tukwila Building Division, NOTE: Revisions will re and may include addi pl n Submittal J s FILE COPY Permit No. Plan review approval is subject to errors and ornksions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receiei of approved Field Co and conditions is acfo we ed: w � CO COVER SHEET Al FLOOR PLAN AI.I FLOOR FINISH PLAN/FINISH SCHEDULE A2 REFLECTED CEILING PLAN AS EXTERIOR ELEVATIONS AND SIGN DETAILS A3.I EXTERIOR 4 INTERIOR ELEVATIONS A3.2 INTERIOR ELEVATIONS A4 SECTIONS/DETAILS AA.1 AS A5.I A52 A5.3 M -I M -2 P -I E -I E -2 E -3 E -4 DETAILS SEC ION /DE AILS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS :'GENERAL NOTES, SPECIFICATION, SCHEDULE 4 LEGEND HVAG PLAN PLUMBING PLAN ": .- .•V.POWER PLAN 'LIGHTING PLAN POWER RISER PANEL SCHEDULES SYMBOL LSENt7 ROOM NAME NORTH KEY NOTE COLUMN NUMBER AND GRID LINE DETAIL NO. SHEET LOCATION SECTION NO. rl II=T LOCATION ELEVATION DESIGNATION <E( PLAN NORDSTROM PAYLESS SHOESOURCE SPACE 2165 LEVEL. 2 OF 3 I. ALL WORK AND BIDDING SHALL REFLECT AND CONFORM TO ALL LOCAL AND STATE BUILDING CODES, ORDINANCES, AND BUILDING INSPECTIONS AND BE ENFORCED BY THE CONTRACTORS AT ALL TIMES. 2. CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND REQUIREMENTS. CONTRACTOR SHALL CONTACT LANDLORD'S REPRESENTATIVE TO VERIFY AND COORDINATE ANY SPECIAL CONDITIONS, REQUIREMENTS, AND RESPONSIBILITIES. CONTRACTOR SHALL ALSO REVIEW ANY TENANT HANDBOOKS AND COMPLY WITH ALL REQUIREMENTS THEREOF. GENRAL NOTES PRIOR TO SUBMITTING HIS BID THE GENERAL CONTRACTOR SHALL CAREFULLY STUDY ALL DRAWINGS AND VERIFY EXTENT OF DEMOLITION WORK (IF REQUIRED) WITH TENANT'S FIELD COORDINATOR. CONTRACTOR SHALL BE RESPONSIBLE FOR FLOOR PATCHING, LEVELING, AND PREPARATION FOR AND OF FLOOR FINISHES. ALL MATERIALS, EQUIPMENT, AND FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SUGGESTED INSTALLATION SPECIFICATIONS. 6. CONTRACTOR SHALL USE GYPSUM BOARD OF THICKNESS NOTED AND WITH TAPERED EDGES. ALL OUTSIDE CORNERS SHALL HAVE METAL SCREWS, CASING BEADS OR CORNER BEADS AS REQUIRED. TAPE ALL JOINTS, BED, AND SAND SMOOTH IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SMOOTH SURFACE TO RECEIVE PAINT. SCREW GYPSUM BOARD TO BACKING. 7. CONTRACTOR SHALL VERIFY BUILDING DEPARTMENT PROCEDURES FOR OBTAINING ALL PERMITS PRIOR TO SUBMITTING BIDS, CONTRACTOR SHALL PAY FOR ALL NECESSARY PERMITS AND /OR FEES REQUIRED BY PUBLIC AUTHORITIES AND /OR UTILITY COMPANIES AND ALL TEMPORARY POWER COSTS. ANY TIE-IN OR INSPECTION FEES TO BE INCLUDED IN BID. CONTRACTOR TO VERIFY IF WATER OR OTHER METERS ARE REQUIRED BY LANDLORD, UTILITY COMPANY, OR BUILDING DEPARTMENT. ALL ASSOCIATED COSTS FOR SAME TO BE INCLUDED IN BID. S. GENERAL CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION, BARRICADES, AND /OR CANOPIES AS REQUIRED BY THE LOCAL AUTHORITIES OR AS NECESSARY FOR PEDESTRIAN SAFETY. q. GENERAL CONTRACTOR SHALL PROVIDE AND HANG FIRE EXTINGUISHERS AND MISCELLANEOUS ITEMS PER TENANT'S OPERATIONS DEPARTMENT OR AS DIRECTED BY LOCAL FIRE DEPARTMENT OFFICIAL. 10. ALL CONDITIONS DESCRIBED IN GENERAL NOTES SHALL BE INCLUDED IN BID. II. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO SUBMITTING SIDS. CONTRACTOR SHALL NOTIFY TENANT IMMEDIATELY UPON ANY /ALL DISCREPANCIES. 12. ALL SPRINKLER WORK MODIFICATIONS SHALL BE COORDINATED WITH ALL OTHER TRADES ON SITE. CONTRACTOR IS RESPONSIBLE FOR ALL SPRINKLER WORK INCLUDING ALL UPGRADES AND MODIFICATIONS, ALL RISERS AND HEADS. ALL SPRINKLER WORK SHALL ACCOMMODATE TENANT APPROVED CONSTRUCTION DRAWINGS AND SPECIFICATIONS. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN /SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO LANDLORD, BUILDING, AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. (IF APPLICABLE). I. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LEAVING PREMISES IN CLEAN CONDITION, READY TO ACCEPT MERCHANDISE. 14. GENERAL CONTRACTOR SHALL VERIFY WITH LANDLORD REQUIREMENTS TO TIE INTO SHOPPING CENTER FIRE ALARM SYSTEM (SMOKE EVACT. SYSTEM IF REQUIRED) AND DETERMINE WHO IS TO FURNISH ALL REQUIRED EQUIPMENT. ALL CONTRACTOR COSTS ARE TO BE COVERED IN BID. (IF APPLICABLE) I. ABSOLUTELY NO ASBESTOS OR ASBESTOS CONTAINING MATERIALS SHALL BE USED IN THE CONSTRUCTION OF THIS PROJECT. 16. ALL REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT AND ANY LOCAL ACCESSIBILITY CODES SHALL BE ADHERED TO. WHEN IN CONFLICT, THE MORE STRINGENT OF THE TWO STANDARDS SHALL GOVERN. 17. THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SUBMITTALS ARE DEFERRED AND MUST BE SUBMITTED SEPARATELY (IF APPLICABLE). IS. GENERAL CONTRACTOR SHALL PROPERLY SEAL ALL PENETRATIONS TO COMPLY WITH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY SHALL BE MAINTAINED. ALL PLUMBING, MECHANICAL, AND ELECTRICAL DEVICES PENETRATING THE FLOOR SHALL BE FIRE RATED. NOTE: THIS DESIGN CRITERIA 15 PROVIDED FOR BUILDING OFFICIAL REVIEW CONVENIENCE ONLY AND IS NOT INTENDED FOR USE BY COMPONENT DESIGNERS OR MANUFACTURES AS THEIR 50LE DESIGN CRITERIA WITHOUT VERIFICATION. EACH DESIGNER AND /OR MANUFACTURER MUST INDEPENDENTLY CONFIRM ALL CODE CRITERIA WITH WHICH HIS ELEMENTS OR COMPONENTS MUST COMPLY, INGLUDIN6 BUT NOT LIMITED TO LOADING, APPLICATION, FUNCTIONALITY, TEC. PERFORMANCE CRITERIA PROVIDED ELSEWHERE BY A SPECIFIC DISCIPLINE SHOULD BE REGARDED AS THE MINIMUM STANDARDS ACCEPTABLE TO THE CLIENT. EACH SUPPLIER MUST EVALUATE THESE MINIMUMS AGAINST SPECIFIC INDUSTRY STANDARDS AS WELL AS CODES, LAWS, ORDINANCES, AND UNDERWRITER REQUIREMENTS GOVERNING HIS PRODUCT AS WELL AS OWNER INSURER REQUIREMENTS, A5 APPLICABLE. THE MOST STRINGENT OF THESE CRITERIA SHALL GOVERN. THE FOLLOWING INDIVIDUALS WERE TEAM MEMBERS INVOLVED IN THIS PROJECT UNDER THE DIRECT SUPERVISION OF THEIR RESPECTIVE PROFESSIONAL or RECORD: TEAM MEMBERS: ARCHITECTURE: HVAG /PLUMB.: ELECTRICAL: GOAL I TY ASSURANCE: TOM SPARER STEVE HOWARD JAY INERNER TOM SPARER CIQNTAITOR IN QR V ATION ARCHITECTURAL PROJECT MANAGER: PROJECT MANAGER: UNION: CONSTRUCTION START: CONSTRUCTION COMPLETE: CONSTRUCTION DURATION: LOCATION: JENNIFER 130ETTGI-IER (785) 270 -1520 JOHN 05IER (785) 270 -1842 SOUTHCENTER MALL 633 SOUTHCENTER PARKWAY, SUITE 2160 TUKWILA, WA IT IS A VIOLATION OF THE LEASE TO FAIL TO CONSTRUCT THIS PROJECT ACCORDING TO THE "TENANT PACKAGE" REQUIREMENTS (TENANT DESIGN AND CONSTRUCTION CRITERIA, CONSTRUCTION RULES AND REGULATIONS FOR I tNANT'S CONTRACTOR, AND SIGN DESIGN AND CONSTRUCTION CRITERIA). ANY DEVIATION FROM THE CRITERIA OR THESE CONSTRUCTION DOCUMENTS MUST HAVE THE TENANT COORDINATOR'S SPECIFIC WRITTEN APPROVAL. PROJ C r iN `O�MATI ON TENANT: LANDLORD: AREA CALCULATIONS: CONSTRUCTION TYPE: OCCUPANCY CLASSIFICATION: OCCUPANCY CALCULATIONS: GOVERNING CODES: BUILDING DEPARTMENT: ARCHITECT/ PROJECT CONSULTANT: PAYLESS SHOESOURCE CORPORATE HEADQUARTERS 120 S.E. 6TH STREET TOWNSITE PLAZA BUILDING #2, SUITE 102 TOPEKA, KS. 66603 P.O. BOX 3541 TOPEKA, K.S. 6660I -55c1I PHONE: (785) 235 -5171 JOHN OSIER, CONSTRUCTION PROJECT MANAGER PHONE: (1S5) 210 -7642 EMAIL: John_OsIer®poyIess.com WESTFIELD, LLC 11601 WILSHIRE BLVD. 14TH FLOOR LOS ANGELES, GA 40025 (360) 843 -4761 ATTN: JOSH KIMMEL SALES AREA IOI OFFICE 102 HALLWAY 103 TOILET ROOMS 104 VESTIBULE TOTAL = 2,512 5.F. = 231 5.F. = 152 S.F. = Isq S.F. ▪ 26 5.F. • 5,120 S.F. TYPE II -B (UNPROTECTED NONCOMBUSTIBLE) M MERCANTILE NUMBER OF EMPLOYEES NOT TO EXCEED (4) AT ANY TIME PUBLIC. AREAS: 2GI6 5.F. - 1 - 30 = 87 NON PUBLIC AREA: x 3 . 02 S.F. + 500 = 2 TOTAL: ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: BUILDING: ELECTRICAL: PLUMBING: MECHANICAL: FIRE: HANDICAP: CITY OF TUKWILA BUILDING DIVISION 6300 50UTHCENTER BOULEVARD, SUITE 100 TUKWILA, WA gSISB 206 -43I -3610 FREIHEIT AND HO ARCHITECTS, INC., P.S. 10230 NE POINTS DR., SUITE 300 KIRKLAND, WA G1S053 (425) 827 -2100 ATTN: TOM SPADER = 8q 2006 IBG W/ WA STATE AMENDMENTS 2006 NEC 2006 UPC 2006 IMO 2006 IFC 2006 IBC W/ WA STATE AMENDMENTS A66RV AT Q\S A.B. A.G.T. A.F.G. A.F.F. B.M. CKT. G CLG. CONC. CONT. OPT. DN. DIA. DWG. EA. E.F. EL. ANCHOR BOLT ACOUSTICAL CEILING TILE ABOVE FINISH CEILING ABOVE FINISH FLOOR BRAKE METAL CIRCUIT CENTERLINE CEILING CONCRETE CONTINUOUS CARPET DOWN DIAMETER DRAWING EACH EACH FACE ELEVATION ELL. EXIST. EXP. F.R. F.T. FIN. GA. GYP.BD. G.G. GALV_ G L. HOW. HST. H.M. H.P. H.A.G. INLAND. ELECTRICAL CONTRACTOR EXISTING EXPANSION FIRE RETARDANT FIRE TREATED FINISH (ED) GAUGE GYPSUM BOARD GENERAL CONTRACTOR GALVANIZED GLASS HARDWARE HEIGHT HOLLOW METAL HIGHPOINT HEATING 4 A/C CONTRACTOR INCANDESCENT JT. LAY. L.P. MAS. MAX. MIN. MR. M.R. MT. N.I.C. NO. O.G. O.H. OPN'G P.B.G. P.G. P55 JOINT LAVATORY LOW POINT MASONRY MAXIMUM MINIMUM MIRROR MOISTURE RESISTANT METAL NOT IN CONTRACT NUMBER ON CENTER OVERHEAD OPENING PLUMBING CONTRACTOR PLATE GLASS PAYLESS SHOESOURCE P.L. PLY'D PT. RAD. R.B. RE: REQ'D ST. T/S T.G. TYP. V.I.F. U.N.O. V.G.T. W/ P. PLASTIC LAMINATE PLYWOOD PAINT RADIUS RESILIENT SASE REFERENCE REQUIRED STEEL TOP OF STEEL TEMPERED GLASS TYPICAL VERIFY IN FIELD UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE WITH WOOD O O 8 T O73 Project North R e v i s i o n s 0 ■111111111111 ■1111111 • 111_ • • • _ Date 2/01 /2008 Descriptlan LANDLORD COMMENTS FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 IQRI4.AN % WA 98033 P:425.8271100 F425.828.15899 FEB — 5 2008 PERMIT CENTEh Si ORE NO. 4307RL PAYLESS 2866 SOUTHCENTER MALL TUKWILA, WA 98188 COVER SHEET DRAWN BY: CF DRAWING NAME: 0765 DATE: 02/04/08 PROJECT NO.: A07 -654 I/4" �1 ��3G� \`G`R2".�:�� ���'� \`F.:� \1`:� f�� ��\�:� \� »�•.� ���� \`C�� \ \ \��� ��� �� \t��t ��:�� ���7► \ \`� \ \ \��� ::�� �� \s:�1�� ��� �:`7\ \tom \ \ \��:��:�� �•.�t »�.5�� �`� � ��\ \��"� \ \C�� „` ��. .1 In Rack In Rack 1-5” Icon Wall 10 OFFICE 2' -11 7 /S" 41' -q 5 /8° Kids Kids I6'-5 3/4" SPECIAL TOP SHELF THI5 SIDE 4' -10' 5'-6 5/8" 17 3 VIA Panels 38'-6 3/S" WOMENS 4 7/S" I2' -3' 4' -1 5 /a" Tn Rack I � I In Rack U 0 0 4•• y III FF -1 II 4' -4°` 86' -0 5 /8' LEASE DIMENSION Sq'-O 3/8" LEASE DIMENSION ADJACENT TENANT ADJACENT TENANT FLOOR PLAN 1/4" = 1' -0" I. CONTRACTOR SHALL HOLD ALL 5A-E5 AREA DIMENSIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE PAYLESS SHOE PROJECT MANAGER. 2. FIF! n VERIFY ALL EXISTING CONDITIONS BEFORE BEGINNING CONSTRUCTION. NOTIFY P55 PROJECT MANAGER AND PROJECT CONSULTANT OF ANY DISCREPANCIES. 3. G.G. TO REFER TO SPECIFICATION SHEET (A5) TO DETERMINE WHETHER A RESPONSIBILITY 15 BY LANDLORD, BY TENANT (PSS), BY TENANT'S G.G. OR AN EXISTING CONDITION. NOTIFY P55 PROJECT MANAGER AND PROJECT CONSULTANT OF ANY DISCREPANCIES. 4. ALL METAL STUDS TO BE 362 5J 20 UNLESS NOTED OTHERWISE. 5. USE (4) NO. 1/4 - 14 SHEET METAL SCREWS A EACH METAL STUD TO METAL 5TUD CONNECTION 6. REFER TO SHEET A2 AND A31 FOR CEILING HEIGHTS 7. A BARRIER FREE SERVICE COUNTER SHALL BE PROVIDED a. A (5# ABC) FIRE EXTINGUISHER SHALL BE PROVIDED PER 2006 FIRE CODE q. ANY MODIFICATIONS TO THE SPRINKLER SYSTEM WILL NEED TO BE APPROVED BY THE FIRE DEPARTMENT. 10. THRESHOLDS: CHANGES IN LEVEL UP TO 1/4" NEED NO EDGE TREATMENT: CHANGES IN LEVEL_ BETWEEN 1/4° AND I/2" SHALL BE A RAMP NO STEEPER THAN I" VERTICAL TO 2° HORIZONTAL. II. DISPLAY FIXTURES: ALL DISPLAY FIXTURES ARE 82" (6' -IO ") IN HEIGHT 12. CONTRACTOR TO FILL AND LEVEL ALL FLOOR AREAS AS REQUIRED IN ACCORDANCE WITH SPECIFICATION 03346. • ,m, , a ,e, i► , a i EXISTING CONSTRUCTION 3 I/2" MTh STUDS @ 16" O.G. W/ 5 /5" TYPE 'X' GYP. BD. BOTH SIDES TO 6" ABOVE CEILING. BRACE AT a' -O" 0. G. W/ 5 1/2" MTL. STUD @ 45° TO ROOF STRUCTURE ABOVE 3 I/2' MTh STUDS @ 16' O.G. I-HR RATED W/ 5/8" TYPE 'X' GYP. BD. BOTH SIDES TO 6° ABOVE CEILING. BRACE AT 8'-O" 0. C.. W/ 3 1/2" MTL. STUD @ 45° TO ROOF STRUCTURE ABOVE 6" MTh STUDS @ 16" O.G. W/ 5 /5" TYPE 'X' GYP. BD. BOTH SIDES TO 6" ABOVE CEILING. (W.R. AT TOILET ROOM). BRACE AT a' -O" O. G. kV 3 I/2" MT1. STUD @ 45° TO ROOF STRUCTURE ABOVE EXISTING 6" MTL STUDS @ 16" D.G. PROVIDE 5 /S" TYPE 'X' GYP. BD. ON TENANT SIDE TO ROOF STRUCTURE. (A.R. AT TOILET ROOM) PURR OUT EXISTING METAL COLUMNS PER DETAIL. 2 I /2" MTL 57UD5 @+ 16" O.G. W/ 5 /5° TYPE 'X' GYP. BD. ON SALES AREA SIDE TO 6" ABOVE CEILING. BRACE AT S'-O" 0. G. kV 3 1/2" MTL. STUD @ 45° TO ROOF STRUCTURE ABOVE <CT'EL;' NQT±S GON'T 21 ELECTRICAL PANEL (SEE ELEC. DWGS 2q LOCKERS PROVIDED BY P55, INSTALLED BY G.G. 30 GOAT RACK PROVIDED BY PSS, INSTALLED BY G.G. 31 OFFICE FIXTURES PROVIDED BY P55, INSTALLED BY G.G. 32 MOVEABLE CART PROVIDED AND INSTALLED BY P55. 33 DESK, FILE CABINET, AND COMPUTER STAND PROVIDED BY P55, INSTALLED BY G.G. 34 CHAIR PROVIDED BY P55, INSTALLED BY G.G. 35 OFFICE SHELVING ABOVE @ 7' -2" A.F.F. (CHOWN DASHED) PROVIDED BY P55, INSTALLED BY G.G. 36� CUT TO FIT. INSTALL 4 "X4 "X4' -O" 10 GAUGE STAINLESS STEEL CORNER GUARDS ON OUTSIDE CORNERS OF ALCOVE. REAR DOOR SIGNAGE: TENANT'S NAME AND SPACE NUMBER, INSTALL 2" HIGH, DIE CUT, VANDAL PROOF, WHITE HELVETICA BLOCK STYLE LETTERS ON A RED = AC RO ► • MO i TED ' - • FF, TE. a+ 0► DO + -. LOQR PLAN <E'I17 NOTES 2 4 7 a 34" HIGH CHECK OUT COUNTER SUPPLIED BY P55, INSTALLED BY G.G., ELECTRICAL CONTRACTOR TO INSTALL COUNTER OUTLETS AS SHOWN ON SHEET E3, OUTLET BOX TO BE LOCATED AT I'-6" I 1/2" X 11/2" FILLER. I' -6" X q' -0" PREFABRICATED CORNER BOX PROVIDED BY P55, INSTALLED BY G.C. DISPLAY FIXTURES SUPPLIED BY P55, INSTALLED BY G.G. END PANEL AND MIRROR PROVIDED BY P55, INSTALLED BY G.G. END PANEL PROVIDED BY P55, INSTALLED BY G.G. END TABLE PROVIDED BY P55, INSTALLED BY G.G. IN RACK MIRROR PROVIDED BY P55, INSTALLED BY G.G. COLUMN FURRING, SEE COLUMN FURRING DETAILS. 1 L =N S AL =LOOK PLAN NOTES Is. LANDLORD SHALL PROVIDE 6" METAL STUD FRAMING FOR ALL DEMISING WALLS. TENANT TO INSTALL 5/S' TYPE X GYPSUM WALLBOARD ON TENANTS SIDE OF DEMISING WALL. TENANT MUST MAINTAIN A 6" MINIMUM CLEAR OPEN HIEGHT ABOVE COMMON TENANT DEMISING WALLS AND BELOW STRUCTURE. 14. CONTRACTOR 15 TO GET APPROVAL AND CORING REQUIREMENTS ON UPPER LEVEL PRIOR TO PROCEEDING WITH WORK. 15. SEE SHEET ALI FOR DOOR SCHEDULE AND DOOR HARDWARE SCHEDULE J 1 A 1 S A L L J i <Er'E NOTES CION'T 12 14 16 17 WOMEN'S BUNDLE FIXTURE PROVIDED BY P55, INSTALLED BY G.G. MEN'S BUNDLE FIXTURE PROVIDED BY P55, INSTALLED BY 6.G. HOT ZONE DISPLAY FIXTURES PROVIDED BY P55, INSTALLED BY G.G. STOREFRONT W/ BUTT JOINTS, SEE I /A4.1 AND 2/A4.I STOREFRONT DOOR PER SCHEDULE ICON -WALL PROVIDED BY P55, INSTALLED BY G.G. FIN END PANEL PROVIDED BY P55, INSTALLED BY G.G., G.C. TO CUT NAILERS ® FIN LOCATIONS. DISPLAY PANEL PROVIDED BY P55, INSTALLED BY G.G. PREFABRICATED WING WALL PROVIDED BY F55, INSTALLED BY G.C. J i 1 L =YeC7 NOTES CON'T la 1 20 21 22 23 [24 1 25 26 LARGE GRAPHIC PROVIDED BY P55, INSTALLED BY 6.C. GRAB BARS. SEE DETAIL IO /A4. SUPPLY SHELF PROVIDED AND INSTALLED BY G.G. FOR ACCESSORIES, FINISHES, ETC., SEE SPECS. TOILET 4 LAVATORY. SEC DETAIL IO /A4. DOOR BELL MOUNTED AT 3' -6" A.F.F., SEE ELECTRICAL DRAWINGS. DEMOLISH PORTION OF EXISTING WALL FOR NEW ALCOVE. PATCH AND REPAIR AS REQUIRED. FIRE EXTINGUISHER (PER CODE AND /OR CODE OFFICIAL) LOCATIONS TO BE DETERMINED AT FINAL INSPEGTION. REFER TO SPEGIFICATIONS. SEE GENERAL NOTE #q ON SHEET CO. PARTITION 5G EIULE 3q 40 41 6.C. IS TO VERIFY THE LOCATION OF BRACING TO ENSURE THAT DOOR GAN BE LOCATED WITHOUT INTERFERENCE. LEASE LINE. SENSORMATIC AMS -3030 FLOOR LOOP, UNDER -SLAB SECURITY LABEL DETECTION SYSTEM (SLC ELEC. DWG5.) RAG< naLL QNflG. NOTES A B G D E MODIFIED SHOPKO - LA. DARLING CONFIGURATION REQUIRES SEISMIC BRACING PAINTED WOOD BASE BY G.G. COVERS SHELVING METAL BASE AND SEISMIC BRACING SEISMIC TIE DOWNS @ SLATWALL AREAS (TYP) ADDITIONAL INNER FRAME TOP SHELF CUT TO FIT L PLIAN�CE OVE 7 nog . TukwilD. P 'T. 7 - 068- 013 F Eb - 5 2008 PERMIT CENTER C5O NU1EERS NER -211 - ER -2156 - ER-2355 SI - ER -4621 - ER -1620 - METAL STUDS - UM -MAST HKT -I4 KWIK -BOLT CONCRETE ANCHORS - HILTI, INC. HILTI LOW - VELOCITY DRIVE AND PNEUMATICALLY DRIVEN FASTENERS - HILTI, INC. KWIK- BOLT -II AND POST NUT KICK- BOLT -II - HILTI, INC. SHEETROCK BRAND WATER - RESISTANT GYPSUM PANELS - UNITED STATES GYPSUM CO., CHICAGO, IL. Revisions Date 2/01/2008 Description LANDLORD COMMENTS FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRNE SUITE 300 KIR1GJND, WA 98033 P:425.8272100 F:425.828.6899 STORE NO. 4307RL PAYLESS 2866 SOUTHCENTER MALL TUKWILA, WA 98188 FLOOR PLAN DRAWN BY: CP DRAWING NAME: 0765 DATE: 02/04/05 PROJECT NO.: A01-65q ELEVATON <= NOTES 2 3 4 5 7 S 10 13 14 15 16 1 IS Iq 20 21 22 25 24 25 26 21 25 2q 30 I x 4 WHITE PINE NAILER, PAINT TO MATCH ADJACENT SURFACE. I X 2 WHITE PINE NAILER, PAINT TO MATCH ADJACENT SURFACE. I X10 WHITE PINE NAILER, PAINT TO MATCH ADJACENT SURFACE. q' -O" H. X I' -6" W. PREFABRICATED CORNER BOX PROVIDED BY P55. INSTALLED BY G.G. FIN END PANEL PROVIDED BY PBS, INSTALLED 5Y G.G. PREFABRICATED WING WALL PROVIDED BY P5S, INSTALLED BY G.G. SLATWALL PANEL PROVIDED BY P55, INSTALLED BY 6.G. CREDENZA GRAPHIC PROVIDED BY P55, INSTALLED BY 6.G. ICON -WALL DESK, FILE, AND COMPUTER TABLE PROVIDED BY P55, INSTALLED BY G.G. LOCKERS $ COAT RACK PROVIDED SY P55, INSTALLED BY G.G. FIRE EXTINGUISHER ELECTRICAL PANEL (SEE ELEC. DINGS. FOR MORE INFORMATION) PHONE BOARD (SEE ELEC. DWGS. FOR MORE INFORMATION) PAINT (P -I) PAINT (P -2) PAINT (P -I) TOP, BOTTOM, SIDES, AND BEHIND POSTER PAINT (P -2) TO EDGE OF PAINT FIN AND FROM TOP OF SASE TO CEILING. ALIGN BOX OF LIGHT FIXTURE 'D' WITH EDGE OF ORANGE PAINT. 4" RUBBER COVE BASE (RS--I) 4" WOOD BASE (W3-1) H.M. DOOR IN H.M. FRAME - PAINT (P -I) BOTH 5IDE5. PROVIDE - QTY. 3 BOSTON RUBBER BUMPER, SERIES 40, COLOR: IVORY, SIZE: 55" 0 LENGTH, G.G. TO INSTALL PER ELEVATION INCLUDE: RUBBER COIL @ 21", ALUMINUM CHANNEL @ 30 1/2" $ 6 END CAPS PER DOOR. MODIFY BUMPER SIZE ACCORDING TO DOOR SIZE. IF OTHER THAN 3' X - 1' DOOR, VERIFY W/ PM. BUMPER PRODUCTS TO BE PROVIDED BY P55 RE PURCHASING. PROVIDE TRIM PROTECTOR BAR. H.M. DOOR IN H.M. FRAME - PAINT (P -I) BOTH 5IDE5. H.M. DOOR IN H.M. FRAME - PAINT (P -I) ON TENANT SIDE, PAINT EXTERIOR SIDE TO MATCH LANDLORD MALL SERVICE CORRIDOR CLEAR TEMPERED GLASS STOREFRONT W/ BUTT JOINTS CLEAR TEMPERED GLASS ENTRY DOOR PAINT TO MATCH MALL SERVICE CORRIDOR COLOR. BASE TO MATCH MALL SERVICE CORRIDOR BASE CORNER GUARD TO MATCH MALL SERVICE G• ID R. 31 32 11/2" ALUMINUM REVEAL, FRY REGLET DC5- 625 -150 OR SIMILAR. LAMINATE (L -2) R E∎hti l; OR CODE COMPLIANCE APPROVE FEB 2 City Of Yukai WILSONART LAMINATE OVER 5/5' GYP. BD., SEE INT. ELEVATIONS FRY REGLET 'J' MOLDING JDM -625 OR SIMILAR �v \\/1 STOREFRONT GLAZING 3/4" X 5/4' CLEAR ANODIZED I µ ALUMINUM REVEAL LEASE LINE ALL NEUTRAL PIER B � OTHERS - � " ELI 5 2008 PERM T CENTER C O NER AT F' SCALE: 1 1/2' = 1' -0" Project North R e v I s i o n s Date 2/01/2005 Description LANDLORD COMMENTS FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 IORIUAND, WA 98033 P:425.8272100 F:425.828.6899 7 REGISTH I n AIZCHITEC i v7 H Eg� S TATE OF WASHINGI N STORE NO. 4307RL PAYLESS 2866 SOUTHCENTER MALL TUKWILA, WA 98188 INTERIOR ELEVATIONS A3.1 DRAWN BY: GP DRAWING NAME: 0765lAS1.dwg DATE: 02/04/08 PROJECT NO.: A07 -65q O Y 211 12 21 OFFICE SCALE: 1/4 "_1' -0" -`Z 25 21 24 HALLWAY SCALE 1/4 " 21-0" 21 21 I ' I I6 1761 21 24 C A 21 C OFFICE SCALE: 1/4 " =1-O" 13 HALLWAY SCALE: 1/4 "_1' -0" 6 21 23 d O n 4 4 - 0 N r 0 cV C OFFICE SCALE: 1/4 " 21' -0" 2Gi f281 i 25 0 21 ALCOVE SCALE: 1/4"-1' -0" 16 C i 21 0 n OFFICE SCALE: 1/4 "_1' -0" 21 n 16 SEE SHEET A3.1 FOR INTERIOR ELEVATION KEYNOTES i�REVIE\IUBD ���� CODE COMPLIANCE APPROVED FEB 2 7 2008 City Of Tukwila BUILDING flsi D08- o� 3 RECER1r- D FEB — 5 2008 PERMIT CENTER Project North Revisions Date 2/01 /2008 Description LANDLORD COMMENTS FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE 5UITE 300 KIRKLAND, WA 98033 P:425.827.2100 F:425.828.6899 REGIS r ! C.) ARCHITEC I STORE NO. 4307RL PAYLESS 2866 SOUTHCENTER MALL TUKWILA, WA 98188 INTERIOR ELEVATIONS A3.2 DRAWN BY: GP DRAWING NAME: 07651A32.dwg DATE: 02/04/O8 PROJECT NO.: A01 -65ci I „a,z o-,Z V v ` T r, I I�I_I J ,, nn C r oo O Y 211 12 21 OFFICE SCALE: 1/4 "_1' -0" -`Z 25 21 24 HALLWAY SCALE 1/4 " 21-0" 21 21 I ' I I6 1761 21 24 C A 21 C OFFICE SCALE: 1/4 " =1-O" 13 HALLWAY SCALE: 1/4 "_1' -0" 6 21 23 d O n 4 4 - 0 N r 0 cV C OFFICE SCALE: 1/4 " 21' -0" 2Gi f281 i 25 0 21 ALCOVE SCALE: 1/4"-1' -0" 16 C i 21 0 n OFFICE SCALE: 1/4 "_1' -0" 21 n 16 SEE SHEET A3.1 FOR INTERIOR ELEVATION KEYNOTES i�REVIE\IUBD ���� CODE COMPLIANCE APPROVED FEB 2 7 2008 City Of Tukwila BUILDING flsi D08- o� 3 RECER1r- D FEB — 5 2008 PERMIT CENTER Project North Revisions Date 2/01 /2008 Description LANDLORD COMMENTS FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE 5UITE 300 KIRKLAND, WA 98033 P:425.827.2100 F:425.828.6899 REGIS r ! C.) ARCHITEC I STORE NO. 4307RL PAYLESS 2866 SOUTHCENTER MALL TUKWILA, WA 98188 INTERIOR ELEVATIONS A3.2 DRAWN BY: GP DRAWING NAME: 07651A32.dwg DATE: 02/04/O8 PROJECT NO.: A01 -65ci JOHNWNITE 0E -XX -A (COLOR TO E3E SELECTED BY OWNER) Y.G.T. TRANS! TI ON V DETA L : V.G.T. TO CARPET TNT I CAL SCALE: 3" = I' -0" TYF I GAL FLAN AND ELEVATION GLEARANGES 6" MAX: I 48 MINIMUM I TOGGLE BOLT. 56" MINIMUM F.R.T. WOOD ANCHORING BLOCKING, CONTINUOUSLY SECURE TO METAL STUDS. SIZE AS REQUIRED G AG GRAS EAR DETAILS 12" MAX. S MIN. KNEE CLEARANC 34 " -41 ° 42' MIN. 11/2' DIAMETER GRAB BAR METAL WALL FLANGE. s TOILET X00 INSULATED PIPES 6° MINIMUM OE CLEARANCE FR.T. WOOD ANCHORING BLOCKING, CONTINUOUSLY SECURE TO METAL STUDS. SIZE AS REQUIRED TOGGLE E3OLT. DETAILS L VARIES VARIES 2. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORGE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF (22.2 N). FAUCETS SHALL COMPLY WITH 4.21.4. LEVER - OPERATED, PUSH- TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS, IF SELF- CLOSING VALVES ARE USED 71•E FAUCET SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS. 3. FLUSH CONTROLS TO BE MOUNTED ON WIDE SIDE'. OF TOILET AREA. (LONG LEAD ITEM WHEN ON RIGHT HAND SIDE) PE.NOANT IS SCALE: N.T.S. ALL TOILET ROOM FIXTURES AND CONSTRUCTION MUST COMPLY WITH LOCAL $ STATE E3UILDING CODES, LOCAL. $ STATE LAWS, AND I4c12 ANSI ACCESSIBILITY GUIDE LINES. METAL WALL FLANGE. I I/2° DIAMETER GRAB BAR FRONT OF CASHWRAP SECTION A TING D -TAIL 13 A4 SGALE: 5' - I'-0" HEAD 5/b" cY VARIES, 5 PLAN -1N JAMB Ui NTE.RI OR DOOR SEE PLAN - RA 5 4" GYPSUM BOARD SEE ELEVATIONS FOR FINIS - S METAL TRACK, SAME GUAGE AS PARTITION V I ° 2 HOLLOW METAL FRAME W/ STOP HOLLOW METAL FRAME W/ STOP (5) ANCHORS PER JAMB (2) METAL STUDS, TYP EACH SIDE OF FRAME 5 /s" GYPSUM BOARD SEE: ELEVATIONS FOR FINISHES SCALE:: NTS II Ii I , I �\ TRANS TRANSI TI ON DETAIL: CARPET TO PORCELAIN TILE SCALE: N.T.S. 4. 4. II" z. II'-0" LIGHT FIXTURE PER ELECTRICAL ON ANGLED WOOD BLOCKING 12'-0" MTL. FRAMING ru 5/8" GYP.BD. SUSPEND FROM STRUCTURE 2' -3" TO CENTERLINE OF FIXTURE s� AGENT UGT 'ETA GYP. BOARD CEILING II 0 6 n 1x4 NAILER (WHITE PINE) PAINT TO MATCH ADJ. SURFACES 8 55/8° TYPE: 'X' GW$ ($0TH SIDES) TO 6° A.F.G. ON 5 5/8" 20 GA. MTL. STUDS @ lb" O.G. TO UNDERSIDE OF DECK. PROVIDE DIAGONAL BRACING AS REQUIRED. A.C.T CEILING (CF -I) A.F.F. NO CEILING, EXPOSED ROOF DECK IxIO NAILER (WHITE PINE:) PAINT TO MATCH ADJ. SURFACES 1x2 NAILER (WHITE PINE) PAINT TO MATCH ADJ. SURFACES 4' RUBBER COVE BASE 3 5/8" METAL BRACING @ 4 O.G. BOTH SIDES ALTERNATING (BRACING REQUIRED IF PARTITION STUD LENGTH EXCEEDS I6-0") - USE (4) NO. 1/4 -14 SHEET METAL SCREWS AT EACH CONNECTION. - ALL METAL STUD MEMi 3ER5 TO BE 362 5,1 20 UNLESS NOTED OTHERWISE. I " 1 1/8'4) POWDER ACTUATED FASTENERS (RAMSET) ® 2' -0' O.G. 10 1x8 NAILER (WHITE PINE) PAINT TO MATCH ADJ. SURFACE S SECTION OCCURS AT SHELVING °E° REFER TO INTERIOR ELEVATIONS FOR NAILER LOCATIONS AT "A ", "B', "G" AND "D" NOTE: SEE DETAIL 41A4 FOR NAILER FASTENING PROCEDURES. hALL SeGTION SCALE: 1/2" = I' -O" OFFICE cv N O N 10 9- in 10 4 ± 81 3/8" A.F.F. FASTEN POINT SALES AREA ± 1 I/2 A.F.F. FASTEN POINT I I I I 1NALL ELEVATION SGM. i 9'01 O a r r r r I i r . METAL STUD 1NALL 9GM..6 SNIP-0' • mom* oll*AW4f*Xcl, 1NOO7 STUD 1NALL cwV.A s•-I'-o. NAILER FASTENING PROCEDURE CONC. BLOCK WA L5 NAILING STRIPS TO BE TOGGLE BOLTED AT 4' -0" O.G. 4 DOUBLE NAILED AT 2' -0° WOOD STUD WALLS NAILING STRIPS TO BE DOUE3L.E NAILED AT EACH STUD W/ I2d COMMON NAILS METAL STUD WALLS NAILING STRIPS TO BE ATTACHED IN/ SHEET METAL FASTENERS, NO TRIM SCREWS \A DETAILS SCALE: 5" = I' -O" METAL OR WOOD STUD BEYOND I X WOOD NAILER NAIL OR SCREW PLACEMENT GYP. BD. (AS REQ'D) METAL STUD PARTITION WALL (SPACING AS REQ'D) GYP. BD. (AS REQ'D) I X WOOD NAILER DOUBLE NO. B SHEET METAL SCREWS MN. 3" LENGTH - COUNTERSUNK) GYP. BD. (AS REQ'D) WOOD STUD PARTITION WALL (SPACING AS REQ'P) GYP. BD. (A5 REQ'P) I X WOOD NAILER I2d COMMON NAILS (DOUBLE NAILED - 3 114" LENGTH) tO84Y73 FEB - 5 2006 PERMIT CENTER (A Project North Revisions Date 2/01/2008 DescriptIon LANDLORD COMMENTS FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SURE 300 IDRIOAAND, WA 98033 P:425.8272100 F:425.828.6899 STORE NO. 4307RL PAYLESS 2866 SOUTHCENTER MALL TUKWILA, WA 98188 SECTIONS /DETAILS DRAWN BY: CP DRAWING NAME: 0165 DATE: 02/04/08 PROJECT NO.: A01 -65 i