Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-078 - WESTFIELD SOUTHCENTER MALL - STARBUCKS - TENANT IMPROVEMENT
STARBUCKS 1047 SOUTHCENTER MALL D08 -078 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D08 -078 Occupant /Tenant: STARBUCKS COFFEE COMPANY Building Address: 1047 SOUTHCENTER MALL, SUITE NO. Parcel No.: 6364200010 Property Owner: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 Use: RESTAURANT Occupancy Group /Division: B Type of Construction: II -B Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: 29 DATE V THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: 6364200010 Address: 1047 SOUTHCENTER MALL TUKW Suite No: Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Tenant: Name: STARBUCKS COFFEE COMPANY Address: 1047 SOUTHCENTER MALL , TUKVVII,A WA Contact Person: Name: VALERIE BARTHOLME - OLYMPIC ASSOCIATES CO Address: 701 DEXTER AVE N #301 , SEATTLE WA 98109 Phone: 206 - 674 -6107 Contractor: Name: R A WARNER PLUMBING CO INC Address: P 0 BOX 820785 , VANCOUVER WA 98682 Phone: Contractor License No: RWARNPC982D 1 DESCRIPTION OF WORK: RESTAURANT TENANT IMPROVEMENT IN NEW MALL SPACE doc: IBC -10/06 CitAf Tukwila • DEVELOPMENT PERMIT Value of Construction: $100,000.00 Fees Collected: $2,111.55 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: II-B Occupancy per IBC: 0008 * *continued on next page ** Permit Number: D08 -078 Issue Date: 05/13/2008 Permit Expires On: 11/09/2008 Expiration Date: 09/16/2009 D08 -078 Printed: 05-13 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governin • this work will be complie • whether specified herein or not. The grant constructio Signature: Print Name: City JP Tukwila • permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating the perf . rmance of work. I am authorized to sign and obtain this development permit. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us dni.) N N Permit Number: D08 - 078 Issue Date: 05/13/2008 Permit Expires On: 11/09/2008 Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non - Profit: N Private: Public: Date: 61-0 Date: — / _ CB This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC - 10/06 D08 -078 Printed: 05-13 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1047 SOUTHCENTER MALL TUKW STARBUCKS COFFEE COMPANY PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: D08 -078 ISSUED 02/08/2008 05/13/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle /King County Department of Public Health, (206/296- 4928), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 10: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 11: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila doc: Cond -10/06 D08 -078 Printed: 05-13 -2008 shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) doc: Cond -10/06 D08 -078 Printed: 05-13 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 32: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 35: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 36: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 37: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** D08 -078 Printed: 05 -13 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The grantin • of - permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or - rformance of work. Sign- • - -. -. \ Print Name: doc: Cond -10/06 D08 -078 Printed: 05 -13 -2008 Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Name: VALE I (2- C)L 'V E -Mail Address: \t b ( QAvv1 _ OK t (A1(1 _,1 e CX- ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: A eg, F Mailing Address: j,1 /-%,\)G- Contact Person: r"--H 2i S L- C4-k E -Mail Address:c`4`c.41 �k23 e-re; i l . c.��v►� Q:\ApplicationsWorms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. e— 078 Mechanical Permit No. Mg "" Oa Plumbing/Gas Permit No. (} B- O s Public Works Permit No. Project No. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: (C:)47 ) 4 2_ MA t._ -E._ Suite Number: King Co Assessor's Tax No.: Tenant Name: iTj4 \ ()c- Lr"x (\ (-1. )'( New Tenant: Yes ❑ ..No Property Owners Name: X G.-c-> c t ',2 — - Mailing Address: 63_3 4--'J £. Tt )K ) f - q (6-3 State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued v.A • City Fax Number: (For office use only) Floor: Day Telephone: (:). , b ( ,c: • = C City State Zip Fax Number: Cr; GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: t Mailing Address: �7 De c - /J.(}P - ,,� J � `�FAZ - `t C t 1-1.K( p E-3(C) Ct City State Zip Contact Contact Person: 1 c 4 - 2 l C= L� l�- , �f -4L� ✓14 Day Telephone: a (? . h (-1- < 6 to E -Mail Address: v 4Ac \.n c 3 (vt� C� r)1( (44 pi, c J x��� s . Fax Number: cs< C �-r t4c_ (N1 Frx.t a.tac- Pe_ urt1132 Ni W j Kt2.Y t , N() k-_)/} R6O City State Zip Day Telephone: - 1A57. 1.3 . (cOS Page 1 of 6 BUILDING PERMIT INIFO -ION - 206 -431 -3670 S Valuation of Project (contractor's bid price): $ /00 000 Existing Building Valuation: $ N A. Scope of Work (please provide detailed information): Co vvl Wt (, c Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: .... Sprinklers A Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:'Applications\Forms- Applications On Lined -2106 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor p � - l I 1 _5 r Floor PSR 1.- 1r-ST''FI F 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INIFO -ION - 206 -431 -3670 S Valuation of Project (contractor's bid price): $ /00 000 Existing Building Valuation: $ N A. Scope of Work (please provide detailed information): Co vvl Wt (, c Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: .... Sprinklers A Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:'Applications\Forms- Applications On Lined -2106 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PUBLIC WORKS PERMIT INFORMATION — 206 -433 -0179 Scope of Work (please provide detailed information): Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District E l ...Tukwila 0... Water District #125 ..Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ ... ValVue Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer El ...Cap or Remove Utilities ❑ ...Frontage Improvements E l ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public ❑ . ❑ . I=1 . ❑ . FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Day Telephone: City State Zip Q:Wpplications\Fomts- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Call before you Dig: 1- 800 -424 -5555 . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line ❑ .. Highline ❑ .. Renton ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Renton ❑ .. Seattle ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Grease interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO# WO# WO # ❑ ...Deduct Water Meter Size Private Private ❑ ...Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <I00K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind • • MECHANICAL PERMIT INFORMATION = 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 0 .o (200 Scope of Work (please provide detailed information): New .... ❑ Use: Residential: Commercial: New .. Replacement .... ❑ Replacement .... ❑ Fuel Type: Electric s g, Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Q: \Applicetions\Forns- Applications On Linc\ -2006 - Permit Apphcation.doc Revised: 9 -2006 bh Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 3 Sinks (� Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent ( Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment ` Repair or alteration of drainage or vent piping ( Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PERMIT INFORMATION — 2064314670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: ...raiV1 _Y \ Mailing Address: State Zip City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 2—C OCR Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): tc _ 1t A 4/1 L/9 (44 -eta IcP St ■/\kC-1 Building Use (per Int'l Building Code): s7__Fc--,7 t t (? i Occupancy (per Int'l Building Code): Utility Purveyor: Water: TO \ Sewer: 1 l I a. Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:\Applications\Fonns- Applications On Lint \3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable.to all permits in this application: Value of Construction = In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER e ' AUTHOR' D AGENT: Signature: - lk■ A "11 I IN EMI. • . fit e IA - Day Telephone: C.FATV City Print Name: Mailing Address: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Q:'Applications\Formc- Applications On Line \M006 = Peimit Application.doc Revised: 9 -2006 hh Date: 0--P..) ao(9 67¢ • 610' P 14/A- 9e, State Zip Date Application Accepted: ,)-- 9-08 Date Application Expires: 9--ag Staff Initials: , , - Q i Page 6 of 6 w 0 0' O- H > a RECEIPT NO: R08 -01594 Initials: WER User ID: 1655 Payee: JOHN GAIN SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431 -3665 Web site: http.• //www.ci.tukwila.wa.us SET RECEIPT SET ID: 0225 SET NAME: STARBUCKS eSMETENTOAD 1,281.50 M08 -036 312.88 PG08 -035 236.00 TOTAL: 1,830.38 TRANSACTION LIST: Type Method Description Amount Payment Check 1960 BUILDING - NONRES MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE TOTAL: 000/322.100 1,277.00 000/322.100 312.88 000.322.103.00.0 236.00 000/386.904 4.50 TOTAL: 1,830.38 Payment Date: 05/13/2008 Total Payment: 1,830.38 1,830.38 1,830.38 Account Code Current Pmts 2354 05/13 9711 TOTAL 1830.38 Receipt No.: R08 - 00364 Initials: WER User ID: 1655 Payee: OLYMPIC ASSOCIATES CO City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: D08 -078 Address: 1047 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/08/2008 Applicant: STARBUCKS COFFEE COMPANY Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 25452 830.05 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 830.05 Total: $830.05 Payment Amount: $830.05 Payment Date: 02/08/2008 02:37 PM Balance: $1,281.50 8401 02/11 9710 TOTAL 1054.50 doc: Receipt -06 Printed: 02 -08 -2008 Project: Type of Inspection: Addres.v Id i-1 `7 M A ! ( Date Called: Special Instructions: Date Wanted: v _ �� cap., Requ�ster: • Phone No: z 6c)- 60 1 ---- tV 6. // INSPECTION RECORD • Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?er,u/7t C.1 Inspector: Date: 7/ / ' ❑ $60.0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 7 R •fM4V 1rSUl '�.�..w - - h • ._ae411.'J.4/dl!Sw . w:_. 1 - - -_ 'S TEg Project: 57�cbb,el Type of Inspection: 'in/ A / Addres : / /9 .// Date Called: Special Instructions: Date Wanted: 7--/- a a.m. c Requester: Phone No: /0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 DOS 6 7' PERMIT NO. (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. $60. + + it INSPECTION FEE REQUIRED. Prior to inspection, fee must be pai .(6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �T` COMMENTS: 1�� D,e. Stiock/57 Inspector: Date: 7�6 / p (Receipt No.: 'Date: Project: 1 Type of Inspection: Address: ol2 Date Called: Special Instructions: Date Wanted 7/11-1)741) C / p.m. Requester: Phone No: 360 0/ 795"(' Approved per applicable codes. 14 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Corrections required prior to approval. COMMENTS: 4.€4 ,2eel 7D A6e 4-41 6-✓ej/ fa e.cea 4-e$44 f /'A7 Inspector: I ; / J $60. d REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: 37/9 f�2 /rr S Type of Inspection: S70C5l h�,Oe.J( /GliVZa Add "0 /71/9// Date Called: ..--- Special Instructions: Date Wanted: , d (a4m 7- I c.)2 P.m. Requester: Phone f�c '6e)/ 7q `/6 g C -0 72- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 6)431 -3670 COMMENTS: Date: 7// Approved per applicable codes. Corrections required prior to approval. r7 $60. I INSPECTION FEE REQUIRED. Prior to inspection, fee must be pai 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pr ��f.1J),74j Type ofo \r Address: /0 fiZ // Date Called: " ■ Special Instructions: Date W/a'nted Q C 4 ��� /�f'� a. m P.m. Requester: —.960 - . 461.7 -- 7 V‘ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Cte.c ►►-�.0 P . Inspector: n-4 p ,Date: a t (1 t n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: ! / � Type of Ins tion Add egsi,477/ Date Called: S Instructions: Date Wanted: 6.. Requester: Phone No: ____6' -- (4 d 7 W 1 /, INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COM y TS: � w / j 9,7 (0(0 4( .c h c� L,: f. 50 Inspector: Date: n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: IK • Project; /4 te Type of Inspection: E 947/4/ A / d/ ! / Date Called: pecial Instructions: . Date Wanted: .-71 Requester: Phone No: —/ -. ..x ��/4 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. INSPECTION RECORD Retain a copy with permit E Approved per applicable codes. Corrections required prior to approval. COMMENTS: l -2, • /IL fc Inspector: G' Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 'A�..exianryns�'i� .,a o►. Project: Type of Inspection: - Addres / 7 7 man 1 I I Date Called: l Special Instructions: Date Wanted /,/ � a:m. m. Requester: Phone No: AO / • 9 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION . 1 2 - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: PA IVA /6 on l / Inspector: Date: -G- o LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ul COMMENTS: 10/j. Type of Inspection: Iv/13 c -IA /2/,-),'$ :"5 4.-" /( - L 8 Address: WO Date Called: c,,,,"/,,--1 - Prx .Ff Si o n / 7r 11 0Ff it f ^ls.4 1., ere,/ # 12 A F,, Giie -v re-D" 1_1,! " , ,5, A 1991 . e . r4 'y Phone No: 36 0 Col 77 Project: 51 14-eIfs Type of Inspection: Iv/13 Address: WO Date Called: Special Instructions: Date Wanted: m Requester: Phone No: 36 0 Col 77 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspector: Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Pro ect: Type of Inspection: Address: 10-17 &I A t Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: 3Ua 'COO 1 - i li INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION lie- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: p Ea.g,L de* ,,, y tad/ 1' J $58. EINSPECTION FEE REQUIRED. Prior to inspection. fee must be pai : at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Date: 5 .... / 4 / 2 1 ; e00 Receipt No.: Date: _.. _ _ r ...• _ _�. r•1•. l....., L. 42-.4ti:1•.t • Project: � rA�2 ge6 Type of Insp tion: e. qcco stir uotb/Q Address 10L Y r '4 / Date Called: Special Instructions: Date Wanted: Requester: P ty '— I J ('7 I INSPECTION NO. INSPECTION RECORD Retain a copy with permit D , -67 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: P l,I Ok. PA Fro .- " , 0,4, 1/5 Inspector: Date: 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: a....ss...nUmb Project: s y Type of Inspection: 6 siAt./ Address: ln`O Sc rot.,,,,-- . Suite #: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: - Hood & Du ct: • Monitor: Pre -Fire: _ Permits: Occupancy Type: -, ;t1= Xias:V§,,3503. . 4w'`:• :'1'•'F.S'."w_:nA'.Ri...T -.Z':; 11_ -.Y �iv!5- •1'.W!�'�°¢ri� ee de. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. n Corrections required prior to approval. COMMENTS: 6tv, O IL- s I . . - - - -- .. • Inspector: t Date: 1 14 rs $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Forin.Doc 1/13/06 T.F.D. Form F.P. 113 Project Type of IInspectio Fire Alarm: Hood & Duct: Address: Suite #: i 7 S . C . rte- L.. Contact Person: SLOW Special Instructions: Phone No.: 3 /3 4 - CO I - 2 2 4. 7 / Needs Shift Inspection : Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: 4 Occupancy Type: a INSPECTION NUMBER pproved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Do 07 8 c-)53 3`l 03 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 ri Corrections required prior to approval. COMMENTS: S f� L cpr �- Ci'a Inspector: i"'` S) I Date: 4 7// / f, Hrs.: j n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 COMMENTS: Type of Inspection: !R- ► .�v...1,,l Address: /0y0 .6 6 in, Suite #: Contact Person: c. e • t,V 514n s - Special Instructions: tt ■ Permits: I 0 r'S 1 0 1400 Nra lil D a. 1 G°C.) f if OIL 11) CO►1E :lt- Pro j ect: rqhe.1311C1 ,4 5 Type of Inspection: !R- ► .�v...1,,l Address: /0y0 .6 6 in, Suite #: Contact Person: c. e • t,V 514n s - Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: «m:'a: P'.;'S�ciSet9�c'NaaFSV]r..et.�H _i!.2s cy+•s:;?•rsf7e5NSYSriaa�.ekrA 'ia xz'4kze.!Jt1+,rG25 !. �3 ;a��r_k•Y•:••kAke'i i44'!'J.4Y '.; r:' �1: :1.+rt!x- Yi'✓�.Yws..G`air.�be�, .acYc': ,.^.Kike4'. '.' = +te:1�.'"i is 'rxA+.. f INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 08- 5- 737 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Approved per applicable codes. n Corrections required prior to approval. Inspector: Date: 5 . 2_ rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: 12.0 tAcK S Sprinklers: Tye of Inspection: Address: j 0.7 Suite #: S. t . Mme. i~, Coma P Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: - Hood & Duct: Monitor: .Pre -Fire: Permits: Occupancy Type: INSPECTION RECORD Retain a copy with pe/mit 8- d - 7c - - - 7 PERMIT NUMBERS CITY OF TUKWILA FIRE ,DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -440 _ INSPECTION NUMBER e9i 14: +' 41S�KN? 2 .t:.-�•:::?'a%�tn,v:KF'£. >.HYfi. 1+ ,±:.'a- %r::.a^rtC. TES 'M#:.ci <:i:.ha:•a."` Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 n Corrections required prior to approval. COMMENTS: wx1 s �k-Ay Inspector: I Date: . 5 - A 2* H rs.. . l n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department., Call to schedule a reinspection. Project In Project' ` Starbucks (S u) Date 1/25/2008 806 Southcenter Blvd, #1310 For Building Department Use � COPY • - -..... ... ---_ — Tukwila, Washington 98188 AP�ant Name. ARM Engineers, ffiC. �� Applicant Address: 11155 120th Ave NE, Kirkland, WA 98033 , Applicant Phone: 425- 739 -6051 Project Description TYPE L563 • New Building • Addition 15 Alteration • Plans Inducted . Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option O Prescriptive O Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist ( over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) - . 1 . 20.0 • No changes are being made to the lighting " From Table 15-1 (over) - document afl exceptions on form LTG-LPA Total Allowed Watts & space use not changed. • Less than 60% of the fixtures new, installed wattage not increased, Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft Mowed x Area TENANT SPACE FAST FOOD 1.30 752.0 977.6 TYPE L563 Bas AREA EXEMPT FOR FOOD PREPARATION 3 294.0 288.0 TYPE L500 Recessed Compact fluor. (1 -18w ?TT lamp) - . 1 . 20.0 20.0 " From Table 15-1 (over) - document afl exceptions on form LTG-LPA Total Allowed Watts 977. 6 Location (floor /room no.) Fbdure Description Number of Fixtures Watts/ Fixture Watts Proposed TYPE L145 Baakbar track lighting (Exempt in food prep area) (in LF) 11 TYPE L563 2x4 Fluor. Troffers (3 -T8 lamps) 3 96.0 288.0 TYPE L500 Recessed Compact fluor. (1 -18w ?TT lamp) - . 1 . 20.0 20.0 TYPE L500 Recessed Compact fluor. (Exempt in food prep _area) -• 10 TYPE L530 Pendant Mt'd Inc. (Exempt in food pre p M area) L, - :. 1 TYPE L037 Floor. Pendant (1-1887 TTY Zany) 1 !) - A b . r 1 14 20.0 80.0 TYPE AD L5 1x4 Fluor. Strips (2 -T8 lamps) l 3 64.0 192.0 1 _ - . 1. Total Proposed Watts may not exceed Total Albwed•Wattsloi Interior Total Proposed Watts 580.0 - 2006 Washington Sate Nonresidential Energy Code Compliance Font Maximum Allowed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG-INT Nevisethiely2007 Proposed Lighting Wattage Notes: 1. For proposed Fbdure Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fodure, and Inks! type (if included). For track lighting, list the length of the track (in feet) in addition to the fodure, lamp, and ballast information. 2. For proposed Watts/Fbdure, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual tuminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fodures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. - cos- ors RECEIVED FEB -8 2008 PERMIT CENTER • Lighting 2008 Washington State Motor, and Transformer Permit Plans. Checklist: LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Starbucks csouTacsiesit II) !Date 1/25/2008 The following information is necessary to check a permit application for compliance with the fighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability I (yes, no, n.a.) Code 'Component Section lntormation Requi ed ( I fin I on Plans Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local controlaccess Schedule with type, ate locations 83.0 yes 1513.2 Area controls Maximum limit per switch 83.0 yes 1513.3 Daylight zone control Schedule with type and features, indicate locations B3.0 yes vertical glazing Indicate vertical glazing on plans 83.0 n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Displaylechihfspecfal Indicate separate controls 313.0 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer Nup Indicate location 83.0 n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning 83.0 EXIT SIGNS (Section 1514) yes 1514 I Max. watts `Indicate watts for each exit sign 1E3.0 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture attache yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture A .. o...� MOTORS (Section 1511) no f 1511 IElec motor efficiency JMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) n.a. { 1540 'Transformers ` Indicate size and efficiency I I 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 5/s Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacily Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location SEE K 2 . . SEE 102.0 Applicant Address: 11155 120th Ave NE, Kirkland, WA 98033 Applicant Phone: 425 -739 -6051 1 L:l-d_ w . . -. _. _ p p p� REC IVED I ha::' a - a1..... .... , I FEB -8 2008 t:)O ...... 07 P ERMIT CFNTF I r. , . I I ,. I 1 Fan Equipment Schedule - s, ' ` ` Equip. ID Brand Name' Model No. CFM SP HP/BHP Flow Control Location of Service , Eflcie �Y SEE K 2 . . SEE 102.0 Applicant Address: 11155 120th Ave NE, Kirkland, WA 98033 Applicant Phone: 425 -739 -6051 1 L:l-d_ w . . -. _. _ p p p� REC IVED I ha::' a - a1..... .... , I FEB -8 2008 t:)O ...... 07 P ERMIT CFNTF I r. , . I I ,. Heating Equipment Schedule Equip. ID Brand Name' Model No. Capac ity Bluth Total CFM or Econo? In but Btuh _ : .Output Btuh , Eflcie �Y Applicant Name: SEE 102.0 Applicant Address: 11155 120th Ave NE, Kirkland, WA 98033 Applicant Phone: 425 -739 -6051 1 L:l-d_ w . . -. _. _ I ha::' a - a1..... .... , I i I r. , . I I ,. I 1 Project Info Project Address Date 1/25/2008 Starba As (sour St u) 806 sonteoemter Blvd, 111310 For Building Dept Use FILE COPY NO. Tukwila, Washington 98188 Applicant Name: ARE Engineers, INC. Applicant Address: 11155 120th Ave NE, Kirkland, WA 98033 Applicant Phone: 425 -739 -6051 Mechanical Summary MECH -SUM 2008 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Indudes Plans 2006 Washington State Nonresidential Energy Code Compliance Form r io 1 ea new series fan powered VAV terminal/8, rr1 ea new split system cooling unit with associated duct work. s Include documentation requiring compliance with commissioning requirements, Section 1416. 1 If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Reined July 2007 �`l�f S r. - ant v1iF Compliance Option O Simple System Q Complex System O Systems Analysis (See Decision Flowchart ( over) for qualifications. Use separate MECH-SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Mechanical Permit Plans Checklist . MECH -CHK 2006 Washington State Nonreaidentbl Energy Code Compliance ones Revived July 2007 Project Address gt�. w 1� ++. -t= (80a'!HCffiai'SS II) Date 1/25/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Nonresidential State Washington Ste sidential Energy Code. Applicability l Code (yes, no, n.a.) Section Component Information Required Location f on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& cog. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, may, efficiency . n.a. 1411.1 Combustion htg. Indicate intermittent ignition, fiueldraft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans 142 yes 14122 Deadband control Indicate 5 degree deadband minimum .0 n.a. 1412.3 Humidity control Indicate humidisfat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 cliff. day types - yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage . n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans . 1412.8 Ventilation Control Indicate demand control ventilation for high-occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule 42.0 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capably on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate cig toad & water econoe & cig tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humicilfication Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary >I - o yes 14142 Duct insulation Indicate R -value of insulation on duct let.o yes 1415.1 Piping insulation Indicate R -value of insulation on piping M 1416 Completion Requirements ` yes 1416.2.1 Commissioning Provide commissioning plan XL 0 yes 141622 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing .0 yes 14162.4 Commissioning Indicate O&M manuals, record drawings, staff training . Yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report NI .0 n . a . 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Completed and attached. Equipment schedule with types, Summary Form input/output, efficiency, cfm, hp, economizer f D SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n. a . 1442 Shut-off controls indicate automatic shut-off yes 1443 Pipe Insulation Indicate R -value of insulation on piping P1.0 h . a . 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover - If "no" is circled for any auestion. provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form a1 Mechanical - Complex Systems .Checklist - - MECH -COMP 2008 Washington State Nonresidential Energy Code Compliance Forms Reed July 2007 Project Address star>bnaas (SOUTH III Date 1/25/2008 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY n ' a. 1431.1 Field assem. sys. Provide calculations n. a. 1432.1 Setback & shut-off Indicate separate systems or show isolation devices on plans n.a. 1 432.2.1 Air system reset Indicate automatic reset n. a. 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves n . a . 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. n.a. 1433 Water Economizer indicate water economizer and provide calculations if 1433 Exception 2 is utilized n . a _ 1434 Separate air sys. Indicate separate systems on plans n. a . 1435 Simul. htg. & dg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified n.a. 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery caiculations n.a. 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency n.a. 1438 Variable flow sys. Indicate variable flow on fan and pump schedules n.a. 1 439.1 Kitchen Hoods Indicate uncoiled and unheated make -up air n.a. 1 439.2 Fume Hoods Indicate VAV, unheated/uncooled or heat rec. makeup 3/ 2006 Washin ' ton State Nonresidential Ener• Code Corn • liance Form no is circled for any question, provige explanation: Project Info Project Address Starbncks (SOUTIKTMTTXR Li) Date 1/25/2008 806 Southcenter Blvd, #1310 For Building Department Use Tukwila, 1Pashington 98188 APPS plane: AER Engineers, INC. Applicant Address: 11155 120th Ave NE, Kirkland, WA 98033 Applicant Phone: 425- 739 -6051 Project Description TYPE L563 ❑ New Building • Addition L7 Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 systems Analysis (See Cezedification Checidist ( over). indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 1 20.0 • No changes are being made to the lighting - From Table 15-1 (over) - document ail exceptions on form LTG-LPA Total Allowed Watts • Less than 60% of the fixtures new, installed wattage not increased. & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft .. Area in ft Allowed x Area TENANT SPACE FAST FOOD 1.30 752.0 977.6 TYPE L563 EAR ARE& EEENPT FOR FOOD PREPARATION 3 2 94.0 288.0 TYPE L500 Recessed Compact fluor. (1 -18w TFT lamp) 1 20.0 20.0 - From Table 15-1 (over) - document ail exceptions on form LTG-LPA Total Allowed Watts 977.6 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed TYPE L145 Eaekbar track lighting (Exempt in food prep area) (in Lf) 11 TYPE L563 2z4 Fluor. Troffers (3-T8 lamps) 3 96.0 288.0 TYPE L500 Recessed Compact fluor. (1 -18w TFT lamp) 1 20.0 20.0 TYPE L500 Recessed Compact fluor. (Ere gt in food prep area) 10 TYPE L530 Pendant }It'd Inc. (Exempt in food prep area) 1 TYPE L037 Fluor. Pendant (1 -18W TTT Lamp) 4 20.0 80.0 TYPE Anal lz4 Fluor. Strips (2-T8 lamps) 3 64.0 192.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 580.0 4 2008 Washington State Nonresidential Energy Code Compliance Farms 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT Redaed July 2007 Maximum Allowed Lighting Wattage Proposed Lighting Wattage Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, fist the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fbxure, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. Lighting,, Motor, and T ransf o r m er Permi Plans Checklist- LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forma Revised July 2007 Project Address st asboares (SoUTECENTER II) !Date 1/25/2008 The following information is necessary to check a permit application for compliance with the fighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability I (yes, no, n.a.) Code Section I Component (Information Required L ocation on Plans 1 Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local controitaccess Schedule with type, indicate locations 83.0 yes 1513.2 Area controls Maximum limit per switch 23.0 yes 1513.3 Daylight zone control Schedule with type and features, indicate locations 83. yes vertical glazing Indicate vertical glazing on plans 83.0 n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib/spectai Indicate separate controls 83. 1513.5 Exterior shut-off Schedule with type and features, indicate location yea (a) timer W/backup Indicate location 23.0 n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n . a . 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning 83.0 EXIT SIGNS (Section 1514) Yes I 1514 1Max. watts 'Indicate wafts for each exit sign 153. 1 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture attache yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fodure ;,. — ... MOTORS (Section 1511) no 1511 lElec motor efficiency `MECH -M0T or Equipment Schedule with hp, rpm, efficiency 1 I I TRANSFORMERS (Section 1540) n.a. I 1540 (Transformers 'Indicate sae and efficiency I I 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 5 /s • Northshore Environmental Health Services 10808 Northeast 145th Street Bothell, WA 98011 -5200 206 - 296 -9791 Fax 206 -296 -9792 TTY Relay: 711 www.kingcounty.gov/health March 13, 2008 Valerie Bartholme Olympic Associates Company 701 Dexter Ave N #301 Seattle, WA 98109 206 - 674 -6107 RE: Plans and Specifications for a new espresso food service establishment: Starbucks, 1047 Southcenter Mall, Tukwila, WA 98188 SR1156460 6712 Dear Ms. Bartholme, • Public Health LA1 Seattle & King County The plans and specifications for the above new project have been reviewed and, in accordance with the provisions of Title 5, the Code of the King County Board of Health Rules and Regulations 05 -06 (The Food Code) are hereby APPROVED. Your establishment has been assigned the following plan review service number ...SR1156460. Please use this SR# in all future contact with us. As required in The Food Code, upon completion of the construction and before opening for business, the food service establishment operator /owner shall: 1. Complete the enclosed application for the annual operations permit if you don't have a current permit. Include a copy of this letter when applying for the annual permit. Please call me prior to paying for your permit to verify the correct fee. Be advised that the penalty for commencing operation of a food service establishment without the required permit is 50% of the applicable permit fee. 2. Obtain a preoperational inspection approval. Contact Diane Agasid - Bondock at the Alder Square District Office (206- 205 -1903) at least one week in advance to schedule a preoperational inspection. Be sure all other inspections (plumbing, building, etc.) are done before you call the Health Department for an inspection. Your application for a food service establishment permit from Public Health Seattle & King County may be approved during this inspection, however it is the responsibility of the food service establishment operator /owner to obtain all necessary permits and approvals from other agencies. Operating the establishment without these required permits or approvals may subject the operator /owner to legal action by the appropriate agencies. If the establishment is opened without the Health Department preoperational inspection, it may be subject to closure. Failed preoperational inspections will require a $100.00 fee for a repeat inspection. If you have any questions, please don't hesitate to contact me. Thank you for your compliance in this matter and I look forward to seeing you soon. Michael Bra Plans Examiner www.michael.bratcherkinqcounty.gov 1J08- 078 RECEIVED MAR 14 ZOOS PERMIT CENTEF ACTIVITY NUMBER: D08 -078 DATE: 02 -08 -08 PROJECT NAME: STARBUCKS COFFEE COMPANY SITE ADDRESS: 1047 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: � 4 C2.2Z g'Division I� IIVYVI vi(/i 2'1EifrDt Public Works Complete Comments: TUESITHURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved 1 1 Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 • • PLAN REVIE %ROUT SLIP 61( /kg, �. -4-d 6 Fire Prevention Structural Incomplete n DETERMINATION O COMPLETENESS: (Tues., Thurs.) DATE: DATE: i ' Planning Division Permit Coordinator DUE DATE: 02 -14 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DUE DATE: 03 -13 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: March 14, 2008 Starbucks Coffee Company PO Box 34067 Seattle, WA 98124 -1067 206/318 -1575 Tukwila Building Division/Permit Center 6300 Southcenter B1, Suite 100 Tukwila, WA 98188 This condition is hereby acknowledged by: ' Acknowledgement to be signed by the responsible officer of the tenant • • RECEIVED (tn Or r > >,•f,, • A MAR 18 2008 Tenant improvement permit for Starbucks Coffee Company, Tukwila Permit No. D08 -078 is issued subject to the following condition: Final inspection approval of this permit and approval of occupancy for the herein named tenant space will not be issued until the "shell" Building Permit No. D06 -147 has received final inspection approval from the Building Division. Con ru chop.) filq Tenant Name: 6(,(Lg , CO9 Title f : Kind of Fixture Fixture Units No. of ixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 2. Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 , Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 '2- Sink, wash fountain, circle spray 4 3 t Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 King County Department of Natural Resources and Parks Wastewater Treatment Division Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type � e•-•'(---- w Plope Street Address " N Owner's Name 14 Subdivision Name Lot # Subdiv. # Block # Building Name City (if applicable) (' 1 O) 0 GI - 4 7t ( Owner's Phone Number (with Area Code) Pro erty Con act Phone umber (with Area Code) Owner's Mailing Address Signature of Owner /Representative Print Name of Owner /Representative 1058 (Rev. 9/07) ,I A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units _ 20 Total Fixture Units l RCE Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Property Tax ID Party to be Billed (if different from owner) City or Sewer District — 11,114.47..4 ` t Date of Connection Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑ Yes ❑ No Was building on Sanitary Sewer? ❑ Yes ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) = 187 C. Total Residential Customer Equivalents: (add A & B) A B RCE White - Kina County Yellow - Local Sewer Aaencv Pin. - Sewer Customer RCE f'r x f ., a ��. D FEB - 8 2008 PEht: i CENTER License Information License WESTECSI62R8 Licensee Name WESTERN CONSTRUCTION SRVCS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600602277 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 4612 NE MINNEHAHA STREET Address 2 09/10/2003 City VANCOUVER County CLARK State WA Zip 98661 Phone 3606995317 Status ACTIVE Specialty l GENERAL Specialty 2 UNUSED Effective Date 12/28/1984 Expiration Date 9/16/2009 Suspend Date Separation Date Parent Company Previous License Next License STRUCSI972MC Associated License Business Owner Information Name Role Effective Date Expiration Date EDWARDS, RONALD R PRESIDENT 09/10/2003 HURD - EDWARDS, JODIE L SECRETARY 09/10/2003 EDWARDS, PATRICIA A PRESIDENT 12/28/1984 09/10/2003 EDWARDS, ROBERT D SECRETARY 12/28/1984 09/10/2003 Look Up a Contractor, Elect Elect lin or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= WESTECS 162R8 05/13/2008 ABBREVIATIONS: GE NERAL NOTES: L DESCRIPTION: APPROVAL STAMPS: PROJECT CONTACTS: 3PL ABS AC ACC ACT ADJ AFF AHJ ALUM AMP APPROX ARCH BD BLDG BLKG BOB BOH CAB CD CKT CLG CLR CM CMNT CMU CNTRS CO CTR CL COL COMP CONC CONT CONST CT CW CWF CWN CWS CXFMR DEC DIA DIM DISP DN DTL DW DWG(S) EA EC ELEC ELEV EQ EQUIP EXIST EXP EXT FC0 FF &E Fl FIN a FIO FIXT FLEX FOC FOG FOH FOIL FOS FRP FLR FT FV GA GALV GC GRND GWB HC HD HDR HDWD HDWR HM THIRD PARTY LOGISTICS ACRYLONITRILE BUTADIENE STYRENE AIR CONDITIONING ACCESSIBLE ACOUSTICAL CEILING TILE ADJUSTABLE ABOVE FINISHED FLOOR AUTHORITIES HAVING JURISDICTION ALUMINUM AMPERAGE APPROXIMATE ARCHITECTURAL BOARD BUILDING BLOCKING BOTTOM OF BEAM BACK OF HOUSE CABINET CONDENSATE DRAIN CIRCUIT CEILING CLEAR /CLEARANCE CONSTRUCTION MANAGER CEMENT CONCRETE, MASONRY UNIT CENTERS COMPANY CENTER CENTER LINE COLUMN COMPARTMENT CONCRETE CONTINUOUS CONSTRUCTION CERAMIC TILE COLD WATER COLD WATER FILTERED COLD WATER NANO FILTERED COLD WATER SOFTENED CURRENT TRANSFORMER DEGREES DIAMETER DIMENSION DISPENSER DOWN DETAIL DISHWASHER DRAWING(S) EACH ELECTRICAL CONTRACTOR ELECTRICAL ELEVATION EQUAL EQUIPMENT EXISTING EXPOSED EXTERIOR FLOOR FURNITURE, CLEANOUT FIXTURES & EQUIPMENT FUTURE INITIATIVES FINISHED FURNISHED & INSTALLED BY OWNER FIXTURE FLEXIBLE FACE OF CABINET FACE OF GLAZING FRONT OF HOUSE FURNISHED BY OWNER INSTALLED BY CONTRACTOR FACE OF STUD FIBERGLASS REINFORCED PANEL FLOOR FOOT /FEET FIELD VERIFY GAUGE GALVANIZED GENERAL CONTRACTOR GROUND GYPSUM WALL BOARD HOLLOW CORE HEAD HEADER HARDWOOD HARDWARE HOLLOW METAL HORZ HR HT HVAC HW D F G NSUL NFO W JC LL MAX MC MDF MECH MEP MERCH MFG MIN MLDG MTL NAT NIC NL NSF NTS OA OC OD OF OFI OPNG PC PERP PLAM PLCS PLEX PLYWD PM FCC POS PT QT R RCM RECEPT REF REFRIG REQ('D) REV RND RO SC SF SHT SHT MTL SIM SOL SPECS SQ SS STG STRUCT STL SUSP SW T &G TEL TEMP TW TYP UC UON V VAL VCT VD VERT VIE WD WH WMV XFMR HORIZONTAL HOUR HEIGHT HEATING VENTILATING AIR CONDITIONING HOT WATER NSIDE DIAMETER NSIDE /INTERIOR FACE NDEPENDENT GROUND NSULATION NFORMATION NDIRECT WASTE JOB CAPTAIN LANDLORD MAXIMUM MECHANICAL CONTRACTOR MEDIUM DENSITY FIBREBOARD MECHANICAL MECHANICAL, ELECTRICAL AND PLUMBING MERCHANDISE UNIT MANUFACTURER MINIMUM MOULDING METAL NATURAL NOT IN CONTRACT NIGHT LIGHT NATIONAL. SANITATION FOUNDATION NOT TO SCALE OVER ALL ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OWNER FURNISHED ITEM OPENING PLUMBING CONTRACTOR PERPENDICULAR PLASTIC LAMINATE PLACES PLEXIGLAS PLYWOOD PROJECT MANAGER POINT OF CONNECTION POINT OF SALE PAINT QUARRY TILE RADIUS RENOVATIONS CONSTRUCTION MANAGER RECEPTACLE REFERENCE REFRIGERATOR REQUIRE(D) REVISED /REVISION ROUND REVERSE SOLID CORESMOSIS SQUARE FEET SHEET SHEET METAL SIMILAR SOLID SPECIFICATION(S) SQUARE STAINLESS STEEL STORAGE STRUCTURAL STEEL SUSPENDED SOFTENED W ATER TONGUE AND GROOVE TELEPHONE TEMPORARY TEMPERED WATER TYPICAL UNDERCOUNTER UNLESS OTHERWISE NOTED VENT VALIDATION VINYL COMPOSITE TILE VENDOR DIRECT VERTICAL VERIFY IN FIELD WOOD WATER HEATER WHITE MAPLE VENEER TRANSFORMER 1 . GC SHALL VISIT THE SITE, REVIEW THE BUILDING SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS SITE SURVEYOR, AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. 2. GC SHALL CONSULT WITH STARBUCKS CONSTRUCTION MANAGER (CM) TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO BIDDING OR CONSTRUCTION 3 ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. 4. GC SHALL VERIFY THE LOCATION OF ALL UTILITIES. 5. GC TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS CM OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS. 6. GC SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK. 7. THE GC IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF SUCH SYSTEMS. 8 GC SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND DOCUMENT ALL CHANGES DURING CONSTRUCTION. THIS SET SHALL BE A PART OF THE GC'S "STORE CLOSE -OUT PACKAGE" AS DESCRIBED IN THE CONSTRUCTION MANAGEMENT AGREEMENT. 9. GC IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS (3PL) DISTRIBUTION SERVICES AND VENDOR DIRECT (VD) SHIPMENTS. REFER TO CONSTRUCTION MANAGEMENT AGREEMENT FOR METHODS AND LEAD TIMES. 10. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED "SHIP". "GC" MEANS THE ITEM IS TO BE SUPPLIED BY THE GC. "3PL" MEANS AN ITEM IS SUPPLIED BY STARBUCKS VIA STARBUCKS CONTRACTED DISTRIBUTION SERVICE AND "VD" MEANS SUPPLIED BY STARBUCKS AND SHIPPED DIRECTLY TO THE SITE FROM THE VENDOR. 11. FOR THE PURPOSE OF THE DOCUMENTS, TO "INSTALL" SHALL MEAN TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS, AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION, UON. PARCEL A, SECTION/TOWNSHIP/RANGE NE 26 23 4, OLIVE GARDEN RESTAURANT -BSP TAX PARCEL # 6364200010 Do& a ` cc R; • _ -- - r . NC 11= > s ., ot "7' 3 } .t e W/ NO1 q�v , ,..,':'' "'? ' ' ^ " -.--- .- ----�" �� FILE COPY Permit No. V O€71b Pler review approval is subject Approval of construction documents the VIQ ` ,f any opy adopte d cads at ap '�ZI• . cond Vb..- - - -a... ". _- � . C • L ` , % _ a , .,~ F .. ; . ,... - - - ,•, ,-,-,re, I ti j n ` : ; f, n ;t+ ; -- ' 1 d r$ . DESIGN MANAGER: ROY HWANG STARBUCKS COFFEE COMPANY 83 KING STREET 6TH FLOOR SEATTLE WA, 98104 206.342.6703 PHONE rhwang@starbucks.com CONSTRUCTION MANAGER: DIANE RANDECKER 206.318.5908 PHONE drandeck @starbucks.com LANDLORD: WESFIELD CORPORATION JOSH KIMMEL 11601 WILSHIRE BLVD. LOS ANGELES CA 90025 PHONE: 206.802.6010 FAX: 206.244.8607 jkimmel@us.westfield.com LANDLORD CONTACT: WESTFIELD CORPORATION ANDREW CIARRIOCCHI 633 SOUTHCENTER BLVD. SEATTLE WA 98188 310.893.4761 aciarriocchi©us.westfield.com ARCHITECT OF RECORD: OLYMPIC ASSOCIATES COMPANY VALERIE BARTHOLME 701 DEXTER AVE N, #301 SEATTLE, WA 98109 206.285.4300 I PHONE 206.285.4371 I FAX MEP CONSULTANT: AER ENGINEERS ATTN. JOHN BEEBE 11155 120TH AVE NE #200 KIRKLAND, WA 98033 425.739.6051 I PHONE 425.739.7362 I FAX aer123 ©aol.com 5 '��AT � � �� REQUIRED FOR: Ki Mechanical & EIectricaI RI I P ing Gas Gas Piping City of Tukwila ilL.OlNG DI to errors and OMISSIOTIS. does not authorize or o nance. R edged: ;< i ons Is ac"�l I N D EX OF SHEETS . PROJECT INFO & SITE SHEETS: G1.0 PROJECT INFORMATION & CONTACTS G2.0 VICINITY MAP, SITE LOCATION, & FLOOR PLAN ARCHITECTURAL SHEETS: - viler Date: .,,,, -" -C3 City Of T a A �4 ���� ` - : :.. , DI Drkfi A0.1 PENETRATION & TRENCHING PLAN A1.0 STOREFRONT ELEVATIONS & SCHEDULE A1.0 STOREFRONT DETAILS A2.0 CONSTRUCTION PLAN A2.1 CONSTRUCTION PLAN DETAILS REFLECTED CEILING PLAN & SCHEDULE A3.1 A3A3..1 1 LIGHTING DIMENSION PLAN 2 CEILING & LIGHTING DETAILS A 3 . FLOOR FINISH PLAN & SCHEDULE A4.1 FLOOR FINISH DETAILS A5.0 WALL FINISH PLAN & SCHEDULES A5.1 INTERIOR ELEVATIONS A5.2 WALL FINISH DETAILS A7.0 CASEWORK PLAN & SCHEDULES A7.1 CASEWORK DETAILS A7. CASEWORK DETAILS A8.0 FURNISHING, FIXTURE & EQUIPMENT PLAN A8.1 AUXILIARY & EQUIPMENT SCHEDULES A8.2 . FURNITURE & MISCELLANEOUS SCHEDULES MECHANICAL / PLUMBING / ELECTRICAL SHEETS: LEGEND: CODE INFORMATION: SITE INFO OCCUPANCY ARROW -- CENTER LINE PAINT /FINISH TAG REVISION DATUM POINT AFF HEIGHT TAGS DOOR NUMBER EQUIPMENT TAG WALL TYPE TAG WALL BLOCKING TAG REVISION CLOUD SCALE BAR DIMENSION LINE FROM FINISH FACE TO FINISH FACE 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL FIRE CODE 2006 UNIFORM PLUMBING CODE IAPMO ( ) 2006 INTERNATIONAL FUEL GAS CODE (IFGC) 2006 WASHINGTON STATE ENERGY CODE AS MODIFIED BY WAC 51 -11, AND THE WASHINGTON STATE VENTILATOR AND INDOOR AIR QUALITY CODE AS MODIFIED BY WAC 51 -13 OR SUCCESSOR. PROJECT DESCRIPTION: COMMERCIAL TENANT IMPROVEMENTS TO EXISTING BUILDING ZONING: TUC TYPE OF USE: RESTAURANT TYPE OF OCCUPANCY: B TYPE OF CONSTRUCTION: II -B UNPROTECTED NON COMBUSTIBLE (PER WESTFIELD) OCCUPANCY LOAD: RETAIL /SEATING: 429 S.F./ 15= 26 BEVERAGE /PREP: 298 S.F./ 200= 2 WORKROOM /STORAGE: 261 S.F./ 300= 1 RESTROOM: 0 S.F./ 0 -- 0 ' 0' -0" -- w BENCHMARK PXXX -E /S � ,, SECTION NUMBER • , "II I SECTION A& 12 �, . � 1 A0.0 • ' TIIiI AO.0) SHEET NUMBER • 3 ELEVATION DETAIL NUMBER DETAIL BUBBLE SHEET NUMBER IS 0 1 2 3 4 8 6'-7 3/4 +X' -XX" DXXX 0 X M1.0 M2.0 M3.0 P1.0 P2.0 P3.0 P4.0 E1.0 E2.0 E4.0 MECHANICAL LEGEND & NOTES HVAC PLAN & SCHEDULE HVAC DETAILS PLUMBING LEGEND & NOTES PLUMBING SUPPLY PLAN & SCHEDULE PLUMBING WASTE & DRAIN PLAN PLUMBING DETAILS ELECTRICAL SPECIFICATIONS ELECTRICAL POWER PLAN & PANEL SCHEDULES LIGHTING E LECTR CAL DETAILS RECEIVED CITY OF TU2� /ILA ter• 7 FEB 08 2008 FER►viii I ULN7 - ER AO 0 TOTAL OCCUPANCY CALC: 29 TOTAL TOTAL SQUARE FEET: 988 S.F. SEATING: 22 SEATS 1 ADA TABLE SPA�A AND FERMff APPRovtL R1LLQJbRED ,� STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND/OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 701 Devil Avanua baltb #301 Seattle, WA 981119 -4342 t; 206.285.4300 L 206.285.4371 Wrr o ly®p1ce SSO[Ialai.Cfl OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION z D U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE PROJECT INFORMATION & CONTACTS SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER G1.0 ABBREVIATIONS: GENERAL NOTES: LEGAL DESCRIPTION: APPROVAL STAMPS: PROJECT CONTACTS 3PL THIRD PARTY LOGISTICS HORZ HORIZONTAL ABS ACRYLONITRILE BUTADIENE HR HOUR STYRENE HT HEIGHT AC AIR CONDITIONING HVAC HEATING VENTILATING ACC ACCESSIBLE AIR CONDITIONING ACT ACOUSTICAL CEILING TILE HW HOT WATER ADJ ADJUSTABLE D NSIDE DIAMETER AFF ABOVE FINISHED FLOOR F NSIDE /INTERIOR FACE AHJ AUTHORITIES HAVING JURISDICTION G NDEPENDENT GROUND ALUM ALUMINUM NSUL NSULAT1ON AMP AMPERAGE NFO NFORMATION APPROX APPROXIMATE W NDIRECT WASTE ARCH ARCHITECTURAL JC JOB CAPTAIN BD BOARD LL LANDLORD BLDG BUILDING MAX MAXIMUM BLKG BLOCKING MC MECHANICAL CONTRACTOR BOB BO BEM D MEDIUM DENSITY HOE i BACK OF E I HOUSE FIBREBOARD CAB CABINET MECH MECHANICAL CD CONDENSATE DRAIN MEP MECHANICAL, ELECTRICAL CKT CIRCUIT AND PLUMBING D CLG CEILING MERCH MERCHANDISE UNIT CLR MANUFACTURER N TU TN MANAGER MIN COS C CMNT CEMENT MLDG MOULDING CMU CONCRETE MASONRY UNIT MTL METAL CNTRS CENTERS NAT NATURAL CO COMPANY NIC NOT IN CONTRACT CTR CENTER NL NIGHT LIGHT CL CENTER LINE NSF NATIONAL SANITATION COL COLUMN FOUNDATION COMP COMPARTMENT COM ARTMEN NTS NOT TO SCALE CONC CONCRETE OA OVER ALL CONT CONTINUOUS OC ON CENTER CONST CONSTRUCTION OD OUTSIDE DIAMETER CT CERAMIC TILE OF OUTSIDE FACE CW COLD WATER OFI OWNER FURNISHED ITEM CWF COLD WATER FILTERED OPNG OPENING CWN COLD WATER NANO FILTERED PC PLUMBING CONTRACTOR COLD WATER CWS SOFTENED PERP PERPENDICULAR CXFMR CURRENT TRANSFORMER PLAM PLASTIC LAMINATE DEC DEGREES PLCS PLACES DIA DIAMETER PLEX PLEXIGLAS DIM DIMENSION PLYWD PLYWOOD P D 5 DISPENSER PM ANA R PROJECT MANAGER DN )OWN CONNECTION DOWN POC POINT OF CO EC ON D IL DETAIL PUS POINT OF SALE DISHWASHER F PAINT N � r AI T W DRAWING T D C�(�) O Q QUARRY TILE S) F A EACH R RADIUS EC ELECTRICAL CONTRACTOR RCM RENOVATIONS CONSTRUCTION ELEC ELECTRICAL MANAGER VA1T N ELEV EL E 0 RECEPT R ECE RECEPTACLE E I AL. EQUAL REF REFERENCE EQUIP EQUIPMENT REFRIG REFRIGERATOR EXIST EXISTING REQ('D) REQUIRE(D) EXP EXPOSED REV REVISED /REVISION EXT EXTERIOR RND ROUND FCO FLOOR CLEANOUT RO REVERSE OSMOSIS FF &E FURNITURE, FIXTURES & EQUIPMENT SC SOLID CORE Fl FUTURE INITIATIVES SF SQUARE FEET FIN FINISHED SHT SHEET Fl FURNISHED & INSTALLED SHT MTL SHEET METAL BY OWNER SIM SIMILAR FIXT FIXTURE SOL SOLID FLEX FLEXIBLE SPECS SPECIFICATION(S) FOC FACE OF CABINET SQ SQUARE FOG FACE OF GLAZING SS STAINLESS STEEL FOH FRONT OF HOUSE STG STORAGE FOIC FURNISHED BY OWNER STRUCT STRUCTURAL INSTALLED BY CONTRACTOR STL STEEL FOS FACE OF STUD SUSP SUSPENDED FRP FIBERGLASS SW SOFTENED WATER REINFORCED PANEL T &G TONGUE AND GROOVE FLR FLOOR TEL TELEPHONE FT FOOT /FEET TEMP TEMPORARY FV FIELD VERIFY TW TEMPERED WATER GA GAUGE TYP TYPICAL GALV GALVANIZED UC UNDERCOUNTER Ero GENERAL CONTRACTOR UON UNLESS OTHERWISE NOTED GYPSUM WALL BOARD VAL VALIDATION HC HOLLOW CORE VCT VINYL COMPOSITE TILE HD HEAD VD VENDOR DIRECT HDR HEADER VERT VERTICAL HDWD HARDWOOD VIF VERIFY IN FIELD HDWR HARDWARE WD WOOD HM HOLLOW METAL WH WATER HEATER WMV WHITE MAPLE VENEER XFMR TRANSFORMER 1. GC SHALL VISIT THE SITE, REVIEW THE BUILDING SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS SITE SURVEYOR, AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. 2. GC SHALL CONSULT WITH STARBUCKS CONSTRUCTION MANAGER (CM) TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO BIDDING OR CONSTRUCTION 3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. 4. GC SHALL VERIFY THE LOCATION OF ALL UTILITIES. 5. GC TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS CM OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS. 6. PATCH AND REPAIR ALL EXISTING WALLS FLOORS CEILINGS OR OTHER GC SHALL E S SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK. ca s a 7. FOR PLUMBING MECHANA A ECTCAL SYTEMS PRIOR TO ITAATION OF L EL c SUCH SYSTEMS. 8. GC SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND DOCUMENT ALL CHANGES DURING CONSTRUCTION. THIS SET SHALL BE A PART OF THE GC'S "STORE CLOSE -OUT PACKAGE" AS DESCRIBED IN THE CONSTRUCTION MANAGEMENT AGREEMENT. DELIVERY OF MATERIALS FROM COORDINATING �1ATERIALS ROM 9 . GC IS RESPONSIBLE F OR C00 D NG DELIVE 0 STARBUCKS CONTRACTED THIRD PARTY LOGISTICS (3PL) DISTRIBUTION SERVICES AND VENDOR DIRECT VD SHIPMENTS. REFER TO CONSTRUCTION MANAGEMENT ( ) AGREEMENT FOR METHODS AND LEAD TIMES. G E OD 10. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED "SHIP". "GC" MEANS THE ITEM IS TO BE SUPPLIED BY THE GC. "3PL" MEANS AN ITEM IS SUPPLIED BY STARBUCKS VIA STARBUCKS CONTRACTED DISTRIB SERVICE AND VD' MEANS SUPPLIED BY STARBUCKS AND SHIPPED DIRECTLY TO THE SITE FROM THE VENDOR. 11 FOR THE PURPOSE OF THE DOCUMENTS TO INSTALL SHALL MEAN TO PROVIDE IN CONNECTIONS, ALL FASTENERS MISCELLANEOUS HARDWARE BLOCKING, ELECTRICAL CONNECT O S SCEL PLUMBING CONNECTIONS AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION UON. - PARCEL A, SECTION/TOWNSHIP/RANGE NE 26 23 4, / / OLIVE GARDEN RESTAURANT -BSP TAX PARCEL # 6364200010 rECEIVEL MAR C 2000 a DESIGN MANAGER: ROY HWANG STARBUCKS COFFEE COMPANY 83 KING STREET 6TH FLOOR SEATTLE WA, 98104 206.342.6703 PHONE rhwang©starbucks.com CONSTRUCTION MANAGER: DIANE RANDECKER 206.318.5908 PHONE drandeck@starbucks.com LANDLORD: WESFIELD CORPORATION JOSH KIMMEL 11601 WILSHIRE BLVD. LOS ANGELES CA 90025 PHONE: 206.802.6010 FAX 6 244.8607 0 jklmmel us.westtleld.com L A T. WESTFIELD C NDLORQ CONTAC ORPORATION ANDREW CIA 633 SOUTHCEN TER BLVD. SEATTLE WA 98188 310.893.4761 aciarriocchKgus.westfield.com ARCHITECT OF RECORD: OLYMPIC ASSOCIATES COMPANY VALERIE BARTHOLME 7 1 DEXTER 0 DE E AVE N, #301 SEATTLE, WA 98109 206.285.4300 I PHONE 206.285.4371 FAX MEP CONSULTANT: AER ENGINEERS ATTN. JOHN BEEBE 55 120TH AVE NE #200 KIR KLAND WA 98033 1 4 5 7 39.605 PHONE 2_. 425 !39.7,562 FAX aer1 aol.com ti ea,:: �:.:�:: _: - .:_..., �:::. �.- :,. `°:.• :;•:::- :.::,- :.- .,.•�. -.A. _ _ so . .: _ -. ,. .. ..... .. .:..:.:.: F-- _..::.,. ,- .- ,.,.. .:::,.._.:.__ - . - - -' -• -: -•. -= _ =;�_; ,.., ;: ,, ' ` �' :. ,;� �. .. r" � \ -,_ � -• - - : ;:;_:.:.; : , r • . . . -«. M4/2 _ _ _- _ - , _ _:- .. .. -.. - .mo ' �, -, :." - - �,• ::. ,. <° ;;. := ::_- - -:..: i: 1. -�_ _. �• -: : ,. a .; -:;,,- �.,.�-- :;:.••,{ ::. �._:;;;. -- : .o � ::;: :::: ::_-= :�= -- :::�,_ �,f.. - = :.. � -> . • ��== _r_ -::__� rx" °:";:,:='.� �: ° °�_.: ca , r ._ ; ,, -. ; , �:�:_: =� -;;� -. - .,.... -: ,, �;„ == �' :� _ -: = =- °-: - -- - N DER c U ® a (F] H O c-m617 - - _ y -' � � _ _ _ _ = _ = _ W UP S -o' 3 0 TO Y5 „ -� - � � e @ m �' - F-• 1 o V `z + :..' _ ' �a _ • °= =' ' _ ` _ z 9 - � . 54 -Z ® -- °O on °° o 1=1 PLAYTOWN v , g a E]a C�' as . °M V- � 120sf 5 39' s" 27 s 61 's ' " ©' • I 13.r� _ 4 - �= �� � � ,- ._:R' o, �, � d - lo ' . 3 03 , � 7.-A �, �' I1�� J •.� „ = - °� � : : . `� JAN. ' �'� m 1-,- _ m m ,� - r x ..::.;. __; B ART)°' } ` ' i ` _ "�` 'F �.� APA `• __ =b �� �� ' �,"�:'. €- :_: -: _ :. ; : -` ::_ ;` '<6 ®Os r ' = = i � :,,. -,' 'ut J` .. - 0° r � .�,; c� � /fi�. - ® _ ,'&). r = : g - 'a , ., >r:_.- '' ` 4 a MI 1 mo a ��° +F A v E' ;6a . -:� -_ - � f ' +n ' zx • az- - ;; ,.,, - `� ��= °' : "= Al. �i o o_ . :.., - : �':._ _.'; =:-:_ , : -- . =. _; : .. 4 . _ :Y - � .: . _:" ::: :_ = '.- • , _ =. _ , , .,. .. - �, . ,f.• -7 �3 f ` : =1- = y �r.. - l �o _f ; I � N �.. �- w � �, " F, : ;'= : ; .___ - d - .;� � -: _;� � - - . - = = =:. _:_ , _ .., _ � - -_ - -- -- - - - - _- - _ 1` 4:; � �1 : ; '• ° ' N ' I 1RI _ ; :.` .: ` = - =-- - � . - '- � `• °�-'- •' - - ` ._ " : .:., :;':_ :_:_ - •__... - -_ - - - - _ • , ,, :;- ;,; -,;: ;;> - .:_...-- = ►" t ' - r,• .. � �� - - ` • ' °` �"`�`- C OAIPA'T - m r. PLA � 1 L S-+; ' F2 • � ... ® . - - - • ::: = :., : =:. l: _:. ` F _........: - � - •876sf� - f - "D kt \Th - ATM2 ■ 3, ; , �� - - - - - t Sxi--t--1-c�� l `1�ES- o I-Nct L-.C� ' i' INDEX OF SHEETS . PROJECT INFO & SITE SHEETS: 01.0 PROJECT INFORMATION & CONTACTS G2.0 VICINITY MAP, SITE LOCATION, & FLOOR PLAN uts,)0 8....... 0 •••••16 ARCHITECTURAL SHEETS: A0.1 PENETRATION A1.0 STOREFRONT A - !;._ ',.0 CON 6 A3.0 R A3.1 LIGHTING A3.2 CEILING A4.0 FLOOR A4.1 FLOOR A5.0 WALL A5.1 INTERIOR • W• � AS_Wr A . ° A:.O U " - �' •r A8.2 FURNITURE MECHANICAL • TR ' & FINISH FINISH FINISH L FI / ' et. NI / PLUMBING & TRENCHING ELEVATIONS AILS C ON ' j+ •DETAILS DIMENSION PLAN LIGHTING DETAILS PLAN &SCHEDULE DETAILS PLAN & SCHEDULES ELEVATIONS H DE . & PL N SCHEDULES r • r �G Fl ' t•� .• "r ■' & MISCELLANEOUS / ELECTRICAL & . - EQUI _ _ 1 PLAN SCHEDULE M NT PLA rr E SCHEDULES SHEETS: LEGEND � ■ CODE INFORMATION SITE INFO / OCCUPANCY � NORTH ARROW CENTER LINE 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL FIRE CODE 2006 UNIFORM PLUMBING CODE ( IAPMO ) 2006 INTERNATIONAL FUEL GAS CODE (IFGC) 2006 WASHINGTON STATE ENERGY CODE AS MODIFIED BY WAC 51 -11, AND THE WASHINGTON STATE VENTILATOR AND INDOOR AIR QUALITY CODE AS MODIFIED BY WAC 51 -13 OR SUCCESSOR. PROJECT DESCRIPTION: COMMERCIAL TENANT IMPROVEMENTS TO EXISTING BUILDING ZONING: TUC TYPE OF USE: RESTAURANT TYPE OF OCCUPANCY: B TYPE OF CONSTRUCTION: II -B UNPROTECTED NON COMBUSTIBLE (PER WESTFIELD) OCCUPANCY LOAD: RETAIL /SEATING: 429 S,F./ 15= 26 BEVERAGE /PREP: 298 S.F./ 200 = 2 WORKROOM /STORAGE: 261 S.F./ 300= 1 RESTROOM: 0 S "F./ 0= 0 0 BENCHMARK PXXX -E /S . PAINT/ FINISH TAG , ,,all SECTION NUMBER A x REVISION II IJ ,r SECTION ''11 A0.0 DATUM POINT ° I 1 9 SHEET NUMBER +X' -XX" AFF HEIGHT TAGS 1 A0.0 > 3 ELEVATION DXXX DOOR NUMBER (----) EQUIPMENT TAG DETAIL NUMBER 1 . WALL TYPE TAG M HAG PLC r r i r P1 0 P - M. 2.0 'LUIBI - P3.0 . PLUMBING P'.0 • I r: E .Q LECT' L ■I 4. E3 "0 LIGHTING E4.0 ELECTRICAL LEGE r TES N CH . E D ► - G S PPLY PLAN & SCHEDULE WASTE & DRAIN PLA r CAL SPECIFICATIO S ' • ': i1 " • + &PANEL SCHEDULES PLAN & SCHEDULE DETAILS AO 0 DETAIL BUBBLE SHEET NUMBER 0 1 2 3 4 IX 111, 8 12 .. WALL BLOCKING TAG REVISION CLOUD SCALE BAR DIMENSION LINE FROM FINISH FACE TO FINISH FACE TOTAL OCCUPANCY CALC: 29 TOTAL TOTAL SQUARE FEET: 988 S.F. SEATING: 22 SEATS 1 ADA TABLE 6 E � E ��� � MAR 0 2000 O. 4 DER sn1 I . > -- E. r -c.- -v -k .�c c 4_ LA. ..121G-(2. S c,.�4 e. PC 4 K . (, • 1 ts.L. ie.t . t�_ P ` . ,0 ?41\.)!_. _ S 4 G-pvc... , STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHING 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 701 0osror Arooco North #301 Seattle, WA 98109 -4344 ❑ 406 000.4300 I, 706 745.4371 x: eva.olan /icossouoles.som OLYMPIC ASSOCIATES COMPANY MAR 1ST 1 3 2000 REV DATE PD DESCRIPTION A PRE-OPENING INSPECTION AR NT CO,UId'I'Y HEALTH I$ I'tm PRIOR TO OPERAT{Oi I• I a TO P� i� 11;1=�►I�t� BE AVAIL , BLE ON SI'T'E IS DURING T AT INSPECTION. STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE PROJECT INFORMATION & CONTACTS SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER G1.0 M(11E" SOUTHCENTER 11 1047 SOUTHCENTER MALL TUKWILA, WA 98188 STARBUCKS COFFEE COUNTY: KING COUNTY ADA KEY: Q LEVEL LANDING THRESHOLD 0 BARRIER --FREE PATH OF TRAVEL O 30" X 48" CLEAR FOR WHEELCHAIR ACCESS O POS, HAND —OFF PLANE AND CONDIMENT COUNTERTOPS ARE 2' --10" AFF FOR WHEELCHAIR ACCESSIBILITY Q ALL THRESHOLDS TO BE ADA COMPLIANT PER ALL APPLICABLE CODES FLOOR PLAN BLENDERS CONDIMENTS BEV DISPENSER ICE BIN WORK SINK HAND OFF PLANES —I RAISED 1 ADA II I I I I I I II COFFEE WARMERS WORK SINK COFFEE REMINDER BREWERS TRASH CD SPINNER �� EXISTING STEEL COLUMN COMMUNITY TABLE HAND SINK FOOD CASE "A" WAR ING STATION SCALE GRINDER CUBBIES ELECTRICAL PANELS BY LANDLORD DISCONNECT BY LL MOP SINK METRO HAND SINK —S I TIZER MANAGERS D SK 3RD PANEL BY SBUX 0 ?f•<: �:: ^. r�w.r"„,. VICINITY MAP NOT TO SCALE NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL III PLUMBING SYSTEMS SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED ACCORDING TO LAW (AP L OCAL, STATE AND FEDERAL STATUTES REGULATIONS AND ORDINANCES).. r HOT WATER GENERATION AND s - DISTRIBUTION` S SHALL BE . SUFFICIENT'TO MEET THE PEAK HOT WATER DEMANDS THROUGHOUT THE FOOD ESTABLISHMENT WAREWASHING /DISHWASHING SINK COMPARTMENTS SHALL BE LARGE ENOUGH TO ACCOMMODATE IMMERSION OF THE LARGEST EQUIPMENT AND UTENSILS. , UTENSIL RACKS, O DRAINBOARDS, S r TABLES LARGE ENOUGH TO - ACCOMMODATE ALL SOILED AND CLEANED iTEMS SHALL BE PROVIDED FOR NECESSARY UTENSIL HOLDING ...BEFORE CLEANING AND AFTER SANITIZING G– o 6 A IOW NORDSTROM 8 14 �.eae : » »wA >: issisY F >»rrii; ;3e:ri;s t rna 1 Ids1 • Fr r y ri rqy gg {. 5 BE ADVISED THAT THE NEW WASHINGTON STATE FOOD CODE REQUIRES COMMERCIAL REFRIGERATION TO HOLD FOOD AT 41 DEGREES FAHRENHEIT OR BELOW I!! (DOWN. FROM 45 DEGREES) FOOD SERVICE OPERATION AREA FLOORS, FLOOR COVERINGS, WALLS, WALL "COVERINGS, AND CEILINGS SHALL BE 'DESIGNED C�ONSTRUCTED,AND INSTALLED SO THEYARE SMOOTH DURABLE AND 'EASILY CLEANABLE LOCKERS OR OTHER SUITABLE FACILITIES SHALL BE PROVIDED FOR THE ORDERLY STORAGE OF EMPLOYEES' CLOTHING AND OTHER POSSESSIONS. 111 Inn E Food equipment that is certified for sanitation by an American National Standards Institute (ANSI)- accredited certification program will be deemed to comply with the food code equipment & utensil materials, construction and design requirements. RESTROOM & KITCHEN HAND WASH SINKS SHALL BE EQUIPPED TO PROVIDE WATER AT A TEMPERATURE OF AT LEAST 100 DEGREES FAHRENHEIT THROUGH A MIXING VALVE OR COMBINATION FAUCET SELF CLOSING OR METERING FAUCETS SHAI1 PROVIDE A FLOW OF WATER FOR AT LEAST 15 SECONDS. It is recco st mmeended that hotwat efor the 'res #room hand wash sinks be plumbe roi n ' il xa �, - �s3 -'g ya, . 7 r from the maidh of �• Using an ins warm type wr heatenunit u nder , eacham ate k = poelp igag STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 701 84rea1 Araaor Na"6 #301 S eottle, WA 90109.4347 f: 2n6.78s.43B0 f: 206.285.4371 w! www,olymplcass,clates.eom OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION H- 0 U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE VICINITY MAP, SITE LOCATION & FLOOR PLAN SCALE: NO SCALE (DO NOT SCALE DRAWINGS) SHEET NUMBER G2.0 DIMENSION DATUM POINT 1-1/2" = 1' -0" CWF STUB UP CW STUB UP ALL CONDUIT STUB UPS TO BE WITHIN THIS BOUNDARY STUB -UPS @ FRONTBAR PLAN DIMENSION DATUM POINT TO POWER PANEL FOR FUTURE 10 MANAGER'S CONDUIT %" CONDUIT T POWER PANEL STUB -UPS @ ESPRESSO BAR 1 -1/2" = 1'--0" ALL CONDUIT STUB UPS TO BE WITHIN THIS BOUNDARY PLAN DIMENSION DATUM POINT 3" POWER CONDUIT ELECTRICAL PANEL )2" PHONE TO MANAGERS Y " DATA TO MANAGERS DE 1 -1/2" = 1' -0" ALL CONDUIT STUB UPS TO BE WITHIN THIS BOUNDARY PASTRY E ASTRYCASE 4 " POWER FUTURE Y , ANAGERS DE STUB -UPS @ DBL P05/SAFE PLAN ALL CONDUIT STUB UPS TO BE WITHIN THIS BOUNDARY DIMENSION DATUM POINT %" LAN COND TO POS / SAFE %" ISOLATED GRO POWER CONDUIT TO MANAG I STATI /4" OWER CONDUIT STUB -UPS @ FRONTBAR 1 -1/2" = 1' -0" , - a „ e- - -e - c Cif LLJ PLAN 0 1 2 3 4 8 12 FLOOR PENETRATION PLAN 36' -9" 36' -5" DR--Drib NOTES: 0 ALL STUB -UP DIMENSIONS ARE RELATIVE TO FINISHED WALL LOCATIONS (SHOWN AS OUTLINES ON THIS PLAN). REFER TO CONSTRUCTION PLAN FOR WALL PLACEMENT. O FLOOR SINK. SEE CUTSHEETS FOR COMPONENT SPECIFICATIONS AND CUTOUT REQUIREMENTS. 0 WASTE LINE PENETRATIONS. SEE PLUMBING SHEETS FOR INDIVIDUAL LINE SPECIFICATIONS. O4 STUB -UP PENETRATIONS. SEE PLUMBING SHEETS FOR INDIVIDUAL STUB -UP SPECIFICATIONS. O STUB -UP PENETRATIONS. SEE ELECTRICAL SHEETS FOR INDIVIDUAL STUB -UP SPECIFICATIONS. WALL LEGEND: RECEIVED CITY OF TU \Ij1fLA FEB 0 8 2008 PERMIT CENTER NEW WALL OUTLINES STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 REGISTERED ARCHITECT 701 Dearer Ample Norp #301 Searle, WA 96109 -4342 t: 206.105.4300 f: 106.285,4371 rr rrr,ofrmpicassociates.com OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION F- z 0 U STORE #: 14777 PROJECT #: 12197-001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE PENETRATION PLAN SCALE: 1 /4"=1'-0 (DO NOT SCALE DRAWINGS) SHEET NUMBER A0.1 ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU # SHIP 00 36" INTERIOR LIT ILLUMINATED LOGO WITH REVEAL AROUND EDGE ELEVATION S352 0 1 2 3 4 8 12 ELEVATION 0 1 2 3 4 8 12 -.7 C") �do ROLLING GRILLE L 0 K ADL7)14" PUSH THROUGH LETTERS ROLLING GRILLE •0 OBLIQUE SIGNAGE SCHEDULE SIGNAGE SCHEDULE: LOGOS 5352 ADDITIONAL ITEMS ADL7 36" SINGL ILLUM DISK 14" PUSH THROUGH LETTERS 120073 VD VD GC TO PROVIDE & INSTALL 2x6 OR 2x8 BLOCKING AS REQUIRED TO SUPPORT SIGNAGE. G.C. TO COORDINATE W/ L.L.'S EXTERIOR SCOPE OF WORK SIGNAGE CONTRACTOR TO EXPEDITE SIGNAGE UNDER SEPARATE PERMIT. SIGNAGE CONTRACTOR SHALL VERIFY SIZE & LOCATION OF ANY & ALL ALLOWABLE MONUMENT OR POLE SIGNAGE WITH LL & PROVIDE SHOP DWG(S) PRIOR TO FABRICATION TO STARBUCKS DESIGNER FOR APPROVAL. SIGNAGE VENDOR OBTAINING PERMIT SHALL VERIFY PERMITABLE DT SIGNAGE, POLE SIGNAGE & SITE SIGNAGE W/ L.L. & LOCAL JURISDICTION PRIOR TO FABRICATION, AND SHALL SEND SUBMITTAL TO STARBUCKS DESIGNER FOR APPROVAL NOTES: STARBUCKS CONTRACTS DIRECTLY WITH SIGNAGE CONTRACTOR TO PERMIT, SUPPLY AND INSTALL SIGNAGE. SIGNAGE CONTRACTOR TO VERIFY SIGNAGE COMPLIANCE WITH LOCAL CODES AND OBTAIN PERMIT AND LANDLORD APPROVAL. 2 GENERAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ELECTRICAL CIRCUIT INCLUDING ALL CONDUIT, WIRE, CONNECTIONS, AND BREAKER AT PANELBOARD NECESSARY TO SERVE SIGNAGE 3 SIGNAGE CONTRACTOR TO SUPPLY SHOP DRAWINGS TO STARBUCKS CM AND TO THE GC AS NEEDED. NOTIFY STARBUCKS CM IMMEDIATELY IF SHOP DRAWINGS OR INSTALLATION IS IN DISCREPANCY WITH STARBUCKS ARCHITECTURAL DRAWINGS. 4 COORDINATE AND SCHEDULE SIGNAGE INSTALLATION WITH THE SIGNAGE CONTRACTOR PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS AND 1 WEEK PRIOR TO SCHEDULED DATE OF INSTALLATION. STARBUCKS CM TO PROVIDE GC WITH SIGNAGE CONTRACTOR CONTACT INFORMATION. RECEIVED CITY OF TIJK'LSfILA FEB 0 B 2000 PERMIT CENTER STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 701 Bever Areeoe North #301 Seattle, WA 98189 -4342 l-. 206,485.4300 I: 206.283.4371 r: www.olym pitossotlates.tam OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE EXTERIOR ELEVATIONS & SCHEDULE SCALE: 1 14 " -1'-0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A1.0 RECESSED LOGO WITH 1" PROJECTION FROM STOREFRONT 1Y2" REVEAL AROUND DISK ELEVATION Z A \\ ELEVATION 0 1 2 3 4 8 12 ss 0 1 2 3 4 8 12 rif)3UQE21 24 -6 1/2 34' -6" N i' SEAM, TYP. OBLIQUE C7 RANDOM ORBIT ALUMINUM BACKGROUN PAINTED WHITE SIM CASEWROK PANELS TO MATCH FRONT BAR CASEWORK 1 y2 REVEAL BETWEEN ALL PANELS 4' -6" 3 -0" 3' -0" STOREFRONT PANELS 4 PANELS PLACED FOR RANDOM PATTERN EFFECT Dos 1' -6" 1'--6" 1 v) DECEIVED CITY OF 1 11143A L FEB 0 8 2008 PERMIT CENTER STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 OLYMPIC ASSOCIATES COMPANY TFRED *JAW C'T EAN BARTHOLME STATE OF WASHINGTON 701 0e11et Avenue Cvth #301 Seattle, WA 98109 -4342 t: 206.285.4300 4: 206.285.4371 w: www.olyupicassacloces.cam REV DATE PD DESCRIPTION H 0 U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: ISSUE DATE: DM: PD: CHECKED: CM: OAC CHECK: diMODA 02.01.08 ROY HWANG MICHELLE PIERRE SCOTT LaROSE DIANE RANDECKER VALERIE BARTHOLME SHEET TITLE STOREFRONT DETAILS SCALE: 1 / 4 " =1 -0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A1.1 rim // i%/////////////% i%////////////////// I/// I///// / / / / / / / / / / / / // / / / ✓ //I /// / / ///.v AFA % % %r 30' -2" HOLD a1 V.I.F. OV.LF. ADL8 CONSTRUCTION PLAN 0 H.: 11 1 3 .. 4 1 12 39 --9" V.I.F. WALL BLOCKING KEY: SYMBOL STARBUC LEASE LINE V.I.F. ITEM SHELVES ABOVE 3 -COMP SINK SHELVES AND DATA RACK AT MANAGER'S DESK UPPER STORAGE (CUBBY) CABINETS AT BACKBAR WEIGHT 200 LBS HEIGHT AFF 5'-8 TO 6'-O" APPROX. WIDTH 8 -0" CENTERED ABOVE 3 -COMP SINK 7' -0" CENTERED ABOVE 300 LBS Y2" ACX PLYWOOD MANAGER'S DESK AND DATA RACK _ BLOCKING SPECIFICATION FOR FRENCH CLEAT MOUNTING SYSTEM TO BE DETERMINED BY ARCHITECT OF RECORD BASED ON INFORMATION PROVIDED ON STARBUCKS' AEC WEBSITE. WALL TYPE LEGEND: WALL TYPE EXISTING WALL NEW PARTITION WALL TO 6" ABOVE CEILING 20 GA 3 5 /8" MTL STUDS 16" 0.0. WITH 5 /8" TYPE "X" GWB ON ONE OR BOTH SIDES TO MIN OF 6" ABOVE CEILING GRID. DRYWALL SCREWS © 12" O.C.. 45 DEGREE MTL STUD REINFORCEMENT © 48" O.C. ABOVE CEILING LINE TO STRUCTURE ABOVE. NEW 1 HOUR PARTITION WALL AT FNISHED CORRIDOR. NEW FURRED PLUMBING WALL TO 6" ABOVE CEILING W/ GREENBOARD 20 GA 6" MTL STUDS 16" 0,0. WITH 5 /g" GREEN BOARD TO CEILING. SECURE THE GREEN BOARD TO STUDS WITH DRYWALL SCREWS AT 10" 0.0. AT PANEL EDGES AND 12" 0.C. AT INTERMIATE SUPPORTS. 45 DEGREE MTL STUD REINFORCEMENT © 48" 0.C. ABOVE CEILING LINE TO STRUCTURE ABOVE NEW PLUMBING WALL TO 6" ABOVE CEILING 20 GA 6" MTL STUDS 16" O.C. WITH 5 /8" TYPE "X" GWB ON ONE OR BOTH SIDES TO MIN OF 6" ABOVE CEILING GRID. DRYWALL SCREWS © 12" 0.0.. 45 DEGREE MTL STUD REINFORCEMENT AT 48" 0.0. ABOVE CEILING LINE TO STRUCTURE ABOVE. NEW PARTIAL- HEIGHT WALL 20 GA 3 5 /8" MTL STUDS 16" O.C. WITH 5 /8" TYPE "X" GWB ON BOTH SIDES TO SPECIFIED HEIGHT. DRYWALL SCREWS ©12" 0.C.. NEW PARTITION WALL --- HEAVIER GAUGE STUD 16 GA 3 MTL STUDS 16" 0.C. WITH 5 /8" GREENBOARD ON BOTH SIDES TO MIN OF 6" ABOVE CEILING GRID. DRYWALL SCREWS ©12" 0.C.. NOTES: CONSTRUCTION /DETAIL LOCATION SEE DETAIL 1/A2.1 SEE DETAIL 4/A2.1 0 EXISTING COLUMN, GC TO V.I.F. J EXISTING WALL LnrEo CO (9 GC TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS CM OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT, Q PROVIDE FIRE TREATED 2X6 OR 2X8 WOOD STUD BLOCKING AS REQ'D TO SUPPORT ANY WALL ATTACHMENTS. 0 NEW STOREFRONT WINDOW SYSTEM AND EXTERIOR DOORS. Q4 LANDLORD TO PROVIDE DOOR HARDWARE PER STARBUCKS' SPECFICATIONS. O VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES MEET STARBUCKS AND /OR CODE REQUIREMENTS. O IF EXISTING EXTERIOR ENTRANCE THRESHOLD EXCEEDS REQUIRED ADA MAXIMUM HEIGHT OF 1/2", REMOVE AND REPLACE WITH ACCESSIBLE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED WITH A SLOPE NO GREATER THAN 1:12. 1/4" GREEN BOARD ON BACKBAR WALL. 0 CASEWORK PANEL, SEE A7.0 FOR SCHEDULE INFORMATION 10 GWB BOARD ON ONE SIDE ONLY 11 SUPPORT COLUMN FOR MOTORIZED ROLLING GRILLE WALL TYPE KEY: EXISTING WALL: NEW WALL: NEW FURRED WALL: RECEIVED CITY OF Tt JK \r nLA FEB 0 8 7rr9 PERMIT r: r. T PD STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 701 Owx1e1 Arm* NIrib ¥381 5,,111,, W4 90109•4343 1: 286.285.4300 1: 206.285.4371 aay. a lym 21 cossocin tes. cam AIIIL OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION 0 U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: dIMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE CONSTRUCTION PLAN SCALE: 1 / 4 " =1-0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A2.O ADL6 1 ROLLING GRILLE ALUMATEK - PACIFIC MOTORIZED GRILLE 2' -3" H FINISH: CLEAR X 23' -1" ANODIZEDVD W ADLS 1 ROLLING GRILLE ALUMATEK -PACIF IC MOTORIZED GRILLE 12'-3" I- FINISH: CLEAR X16' -6" ANCDIZEDVD W DOOR SCHEDULE, TYPES, AND HARDWARE: DOORS SCHEDULE: ITEM# DOORS D065 QTY ADDITIONAL ITEMS DOOR LEGEND: CONSTRUCTION: SC = SOLID CORE HM = HOLLOW METAL AL = AL STOREFRONT WD = WOOD STOREFRONT E = EXISTING MISCELLANEOUS: U = Y2" UNDERCUT 000 FRENCH CLEAT REFER TO AEC WEBSITE FOR MOUNTING DETAILS 2' -10" A.F.F. (BACKBAR COUNTERTOP) LO 3 4" = " LOCATION /SIZE WORKROOM / 36X84 RATING: MANUFACTURER ELIASON GLAZING: T = TEMPERED W W WIRE NR = NON RATED 1HR = 1 HOUR 2HR = 2 HOUR TILE BASE MODEL # SCP4 FRAME: WALL SECTION @ BACKBAR SECTION SC AL = AL STOREFRONT HM1 = HOLLOW METAL SINGLE RABBET HM2 = HOLLOW METAL DOUBLE RABBET HM3 = HOLLOW METAL SINGLE RABBET FOR CMU WALL HM4 = HOLLOW METAL NO RABBET CONST. GLAZING RATING NR FRAME HM4 DOOR TYPES: MENU BOARD HEIGHT ADJUSTABLE Y GREEN BOARD TILE SUBSTRATE BY G.C. BACKBAR 11LE @ EXPOSED WALL SURFACE BETWEEN BASE OF STORAGE CUBBBY AND TOP OF BACKSPLASH SOLID SURFACE COUNTERTOP W/ INTEGRAL BACKSPLASH --------- ELECTRICAL OUTLET ADJUSTABLE LEGS NOTES HRDWR 11 TYPE REMARKS ED 1' -7" AFF (CW SUPPLY) O 1' -6" AFF (CWF SUPPLY) Q 1' -5" AFF (HW SUPPLY) a VARIES: Y4 PER FT. FALL (ABS 2" WASTE Q 45 LBS DEAD LOAD FOR LIQUID STORAGE OVER AND ABOVE THE CASEWORK ITSELF. Q A LIVE LOAD OF A PARTNER EITHER PULLING AND OR CLIMBING ON THE CASEWORK O SEISMIC ACCELERATION CONDITIONS AT THE SITE. LINE) TYPE "F" SKU # SHIP GC 1 1/2" = 1' -0" . d. U.L. NO. U465 THE FOLLOWING FASTENING REQUIREMENTS ARE TAKEN FROM UL'S SPECIFICATION FOR THE INDICATED ASSEMBLY. REFER TO UL'S DOCUMENTATION FOR COMPLETE ASSEMBLY REQUIREMENTS AND ALLOWABLE OPTIONS: GYPSUM BOARD: 5/8" THICK, 4 FT WIDE, ATTACHED TO STEEL STUDS AND FLOOR AND CEILING TRACK WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 8 IN. OC. ALONG EDGES OF BOARD AND 12 IN. OC IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. 1 HR DEMISING PARTITION (TYP) HARDWARE SETS: SET #1 QTY PART # 1 ARMS1850 1 BBW443 2 FALA100C 1 FALA100CCK 9 FALA100CUK 2 LN2049 2 LN2053 SET #6 QTY PART # 1 DORMA8916 1 FALT301 3 GJ64 1 ROC473 2 ROCJ102 3 STAFBB179 SET #11 (1) ELIASON DOOR PACKAGED SET #12 QTY PART # 1 DORMA8916 1 FALA100C 1 I/O 2000L -03IC 1 LN2068 1 NGP13717 1 NUMCN304 1 PEM 18062 1 ROCJ102 3 STAFBB191NRP PAINTABLE FIRESTOP SEALANT (BOTH SIDES) UNDERSIDE OF DECK ABOVE /8" DEFLECTION GAP 6" SLOTTED TRACK (SLP --TRK OR EQ) FINISH PER SCHEDULE NOTE FIRE RATING OF WALL ASSEMBLY IS NOT REQUIRED TO MEND ABOVE TENANT CEDING. GYPSUM BOARD TO BE HELD MIN. 6' BELOW UNDERSIDE OF DECK ABOVE TO ACCOMMODATE 1ENANT HVAC RETURN AIR SYSTEM CEILING BY TENANT (WHERE OCCURS) 6" STEEL STUDS ® 16" O.C. 5/8" GYPSUM BOARD TYPE "X" (BOTH SIDES) RAMSET AS REQUIRED 6" CONTINUOUS UNPUNCHED STEEL TRACK FLOOR FINISH CONCRETE SLAB, SEE STRUCTURAL DRAWINGS PAINTABLE FIRESTOP SEALANT (BOTH SIDES) NOTE. ALL GYPSUM BOARD LAYERS SHALL BE SUPPLIED AND INSTALLED BY TENANT PART DETAIL ADAMS RITE DOOR LOCK MS1850S DEADBOLT BBW SIGN "THIS DOOR TO REMAIN UNLOCKED" FALCON 7 PIN CORE COMBINATED "A" KEYWAY 626 FINISH 1 -1 FALCON CUT CONTROL KEY "A" KEYWAY FALCON CUT USER KEY "A" KEYWAY" MORTISE CYL SHELL 7 PIN W /AR CAM S.CHROME (26D) FINISH ADJUSTABLE RING, MORTISE CYL 5/16 -13/32 S.CHROME 26D FINISH PART DETAIL DOOR CLOSER 8916 AF89P AL DORMA FALCON PRIVACY LEVERSET 626 2 B /SET QUANTUM DESIGN GLENN JOHNSON RUBBER SILENCER ROCKWOOD DOOR STOP W /HOOK (473) ROCKWOOD KITPLATE 10" x 34" STANLEY DOOR HINGE 4.5" x 4.5" WITH HARDWARE. (VD) PART DETAIL DOOR CLOSER 8916 AF89P AL DORMA FALCON 7 PIN CORE COMBINATED "A" KEYWAY 626 FINISH1-1 SUR -LOCK AUTO LOCKING DOOR ALARM, IC; NO CTR INCLUDES MORTISE CYLINDER DOOR SPY, DESCO, SILVER, DS -6 NGP WEATHER STRIP 17' 36" x 84" NUTONE DOOR BELL PEMKO DOOR SWEEP 36" ROCKWOOD KITPLATE 10" x 34" STANLEY DOOR HINGE 4.5" x 4.5" N.R.P. 32D NOTES: 1 ALL DOORS TO PROVIDE 32" MIN CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION UON. 0 FALCON LOCK CORE(S) TO BE INSTALLED ON THE DAY OF TURNOVER. NOTE: FIRE RATING OF WALL ASSEMBLY IS NOT REQUIRED TO MEND ABOVE TENANT CE.AJNG. GYPSUM BOARD TO BE HELD MW. 6' CLEAR BELOW UNDERSIDE OF DECK ABOVE TO ACCOMMODATE TENANT HVAC RETURN AIR SYSTEM. NOT TO SCALE 1/2 q 'd d 4 a. e a:4 UNDERSIDE OF DECK ABOVE 6" SLOIILO TRACK (SLP -TRK OR EQ) FINISH PER SCHEDULE CEILING BY TENANT (WHERE OCCURS) 6" STEEL STUDS 0 16' O.C. 5/8" GYPSUM BOARD TYPE "X' (BOTH SIDES) U.L NO. U465 THE FOLLOWING FASTENING REQUIREMENTS ARE TAKEN FROM UL'S SPECIFICATION FOR THE INDICATED ASSEMBLY. REFER TO UL'S DOCUMENTATION FOR COMPLETE ASSEMBLY REQUIREMENTS AND ALLOWABLE OPTIONS: GYPSUM BOARD: 5/8" THICK, 4 FT WIDE, ATTACHED TO STEEL STUDS AND FLOOR AND CEILING TRACK WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 8 IN. OC. ALONG EDGES OF BOARD AND 12 IN. OC IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. RAMSET AS REQUIRED 6 CONTINUOUS UNPUNCHED STEEL TRACK FLOOR FINISH CONCRETE SLAB, SEE STRUCTURAL DRAWINGS PAINTABLE FIRESTOP SEALANT (BOTH SIDES) NOTE AU_ GYPSUM BOARD LAYERS SHALL BE SUPPLIED AND INSTALLED BY TENANT 1 HR TENANT DEMISING PARTITION (TYPICAL) 1 I SECTION Q FLOOR 1 =1 METAL STUDS (PER WALL TYPE) @ 16" O.C. TO UNDERSIDE OF ROOF STRUCTURE, TO MINIMUM OF 6" ABOVE SUSPENDED CEILING OR TO UNDERSIDE OF EXIS11NG SOFFIT OR CEILING. MTL STUDS TO MEET I.C.B.O. #1715P OR EQ. NAIL STUD RUNNER TO FLOOR W/ HILTI NK FASTENERS, 1 1/8 " MINIMUM PENETRATION 32' O.C., MAXIMUM. ( I.C.B.O. #2388) EXISTING CONCRETE SLAB SECTION ( CEILING - EXISTING ROOF STRUCTURE NEW PARTITION WALL 6 " ABOVE CEILING / / / / / / / / / / / / / / / - / 20 GA 3 MTL STUD BRACING AT 48" O.C.. ATTACH TO PARTITION FRAMING W/ 3 /8" PAN HEAD TYPE "S" SCREWS. USE LATERAL BRACING WHEN PARTITION FRAMING DOES NOT ATTACH TO ROOF STRUCTURE. SUSPENDED CEILING, AS OCCURS %" G.W.B. TYPE "X ", BOT,H A BOVE CEILING. TYPE OF "5 " DRYWALL SCREWS ©8 0,C. TO VERTICAL EDGES & 12 O.C. TO INTERMEDIA(E STUDS. STAGGER JOINTS 24' 0.C., EACH SIDE. RECEIVED CITY OF TLIKWILA fEB 0/2 r Pi € IT CENTER STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS. AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORPON OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 REGISTERED ARCHITECT 701 Orrrer Arcane North *30I Se911/e, NA 95109 -4342 r 256.235.4300 f: 206.255.4371 �. "”.olymplcossocloros.com AIIII OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION 1 z O 0 z O U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE CONSTRUCTION PLAN DETAILS SCALE: VARIES (DO NOT SCALE DRAWINGS) SHEET NUMBER A2.1 T100 0 ACT MAIN RUNNER - WHITE ARMSTRONG 7300WH MAIN RUNNER TO BE USED WITH WHITE TILES ONLY ------ GC T102 0 ACT 2' CROSS TEE --- WHITE ARMSTRONG XL7328WH 2' CROSS TEE TO BE USED WITH WHITE TILES ONLY GC T103 0 ACT WALL ANGLE --- WHITE ARMSTRONG 7800WH WALL ANGLE WH TO BE USED WITH WHITE TILES ONLY GC ADL4 1 TRANSLUCENT CEILING PANELS USG TRANSLUCENTS : CLEAR FLAT 2X2 SQ FT PANEL : 75 VD GWB BULKHEAD I SOFFIT Q P836 -E /S BULDKHEAD ABOVE \ GWB BULKHEAD I SOFFIT +10' -6" P883 -E /S I I I II I I _ = _I_1 11 �=== = I 0 10" GWB BULKHEAD I SOFFIT Q P836 -E /S GWB CEILING I SOFFIT 0000 BOTTOM OF SOFFIT TOP OF SOFFIT 6 ' -4 ,e REFLECTED CEILING PLAN 0 1 2 3 4 8 12 P835 -sic + 8' -8" +9'-6" C -5" HEADER +9' -0" P836 -E /S 5-7 ,, GWB CEILING I SOFFIT 0000 +10' -6" GWB OILING I SOFFIT P832 -S /G 8' -8" P830 -S /G CEILING FINISH SCHEDULE: CEILINGS SCHEDULE: ITEM# QTY DESCRIPTION MANUFACTURER MODEL # ACT CEILING T001 348.74 GWB CEILING I SOFFIT ADDITIONAL ITEMS ILLUMINATED PANEL SYSTEM <ADL +9' - 4" +10' -0" ACT - WHITE VINYL (QTY =SQ FT) P842 --5 /G WORKROOM I ACT TILES (T001) 0000 +10' -0" ARMSTRONG #670 I I II II — II — —°- - — — SOFFIT PLAN REMARKS GRID COLOR TO MATCH SKU # SHIP GC NOTES: DbZ06 Q PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES / SUPPORTS. �2 PAINT ALL HVAC DUCTS, HVAC DIFFUSERS, RECESSED SPEAKERS & LIGHT TRIM RINGS THE SAME COLOR AS CEILING OR SOFFIT, TYPICAL THROUGHOUT RETAIL PORTION OF STORE. 4Q PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. REFER TO WALL FINISH PLAN FOR PAINT SCHEDULE. 5E COORDINATE DUCT LOCATION AND DIFFUSERS SIZE WITH MECHANICAL SHEET. DIFFUSERS & RETURNS @ BACKBAR IN ACT TO CENTERED IN TILE, LEAVE WHITE. O7 IF REQUIRED BY LOCAL CODE, GC TO PROVIDE SEMI - RECESSED SPRINKLER HEADS W/ POLISHED CHROME ESCUTCHEONS CENTERED IN ACT. IF PENDANT HEADS ARE REQUIRED IN GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GC TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS CM FOR APPROVAL PRIOR TO INSTALLATION. 8Q ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO VERIFY NUMBERS MATCH THE COLORS CALLED OUT. CONTACT: PHYLLIS MILLER (800) 442 -4212 a g FOR HEIGHTS AT STOREFRONT SOFFIT, CEILING, SIGNAGE, AND ROLLING GRILLE MOTOR /STORAGE SEE DETAILS ON A3.2 SHEET. RECEIVED CITY OF Tt I K'"fILA. FEB 08 2008 A I r' ITr-r, IN,/ STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 701 Dexter Aveaue North 4381 Seattle, WA 98189.4342 1: 206.285.4300 I: 206.285.4371 w w.w.olympicasspdples.aem Aisik OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION w w U- O co W Z W CC 0 CO I— D 0 CO U w 0 I_ H z 0 0 STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE REFLECTED CEILING PLAN & SCHEDULE SCALE: 1 / 4 =1-0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A3.0 • II I I II II II I LIGHTING DIMENSION PLAN 0 1 2 3 4 8 12 NOTES: D0 078 0 FLUORESCENT LIGHTING AT WORK ROOM AND LIGHTS IDENTIFIED WITH "NC TO BE ON A 24 HOUR /DAY LOCK -ON CIRCUIT O LIGHTING FIXTURES IN ACT TO BE CENTERED IN TILE, UON 0 CENTER EMERGENCY / EXIT LIGHTS ABOVE DOORS, UON • SUSPEND BOTTOM OF PENDANT LIGHTING FIXTURES @ 6' -0" AFF Q CD SURFACE -MOUNT TRACK DIRECTLY TO SOFFIT NUMBER NOT USED • ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS MUSIC SPEAKER WHERE INDICATED. RECEIVED CITY OF TI n<v lLA FEB 08 2008 PERMIT CENTER STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 875$ 781 [Inter Al.cee North #301 Seoltle, WA 98189.4342 t: 286.285.4388 I: 206.285.4371 w w.ulynp icossor ioles.tox ANIL OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION CO oo oo J I- z a U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: dIMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE LIGHTING DIMENSION PLAN SCALE: 1 14 =1 -0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A3.1 COMPRESSION STRUT GUIDELINES CASEWORK PANEL STOREFRONT SYSTEM ." I , � y __/_\--) S• «91.. / J d } I r / - '� . � ( gekt COMPRESSION STRUT SIZE MAXIMUM LENGTH Y DIAMETER GONQUIT 8 -6" EXIT /EMERGENCY LIGHT LIGHING I\ I I . PANEL I I I 7. I I 1 DIAMETER CONDUIT (EMT) 10.0 ., k . — )1' -6" 0.18') TYP FLOUREsCENT FICTURES TRANSLUCENT DROP PANEL SYSTEM @ 9' -4" LJ ;� - BACK -TO -BACK 0/2" x 20 GAUGE METAL STUD SCREWED TOGETHER © 24" O.C. 15'- --0 45 MAX. 1 _ 7 PAINT ' f� � - " 1,....._. � ALL SIDES ABOVE DROP CEILING I I VERTICAL COMPRESSION STRUT 2" MAX. FROM BRACING WIRES TO CROSS TEES / 45A MAX. t \` 0 -4‘`Illr I � ,ppp 12 GA HANGER WIRE @ 48" 0.C. EA. WAY TO BE ATTACHED @ MAX OF 45 DEGREES, MIN OF 4 TIGHT TURNS IN 142" @ BOTH SIDES OF ALL BRACING WIRE M AIN RUNNER @ 4'-0" O.C. HEADER @ 9' -0" y MOTOR CASEWORK STOREFRONT SYSTEM GWB PAINTED I ( ' .. OPERATOR — — — — — - - 6 ?" r y / BOTTOM CAP OF GRILL= BRACKING 45 MAX. '�� 45" MAX. S S I NOTES: 1. ALL BE SUPPORTED SYSTEM 2. FLAME 3. IF REQUIRED 4. ATTACH 45 REPLACE 15 S TE O.C. OR 1' -0" O.C. AS SHOWN 24 "X48" CEILING LIGHT FIXTURES & 24 ° X24" HVAC AIR REGISTERS SHALL BY A MINIMUM OF (2) HANGERS @ OPPOSITE CORNERS. CEILING SHALL NOT SUPPORT OTHER ITEMS. ALL INTERIOR WALL & CEILING FINISHES SHALL BE INSTALLED TO CLASS III SPREAD. 45 DEGREE BRACE WIRES & COMPRESSION STUDS ARE TO BE PROVIDED ONLY BY LOCAL BUILDING DEPARTMENT. M COMPRESSION STRUTS : STEEL SECTION WITH L/R RATIO OF 2 00 MAXIMUM. TO MAIN RUNNERS WITH Y4" MACHINE BOLT AND TO STRUCTURE WITH DIAMETER POWER DRIVEN STUD. COMPRESSION STRUT SHALL NOT HANGER WIRE. T BAR CEILING DETAIL - SEISMIC REQUIREMENTS —_ / _____ b v 076 I gp q I I ■ _ 14" PUSH THROUGH LETTERS Bo ON ONE ELEVATION ONLY ROLLING GRILLE MOTOR @ 12' --10: I Ak IMF n n >7 GWB CEILING @ 11' -6" -- MERCHANDISE UNITS, FOR REFERENCE ONLY EXISTIG COLUMN WRAPPED WITH GWB SIGN BOX & GWN STOREFRONT CEILING @ 10'-61 - I 14 HEADER AND TRANSLUCENT PANEL DROP SYSTEM - - _ BOTTOM OF BARISTA GWB SOFFIT @ 8' -8" I I NTS� ., I — 0 1 O Y vv y fy • s c - folk- a mipookf - ` 1 Nr - ' • ogas • F 1C--9) 8 — BOTTOM OF RECCESSED 36" LOGO DISK @ 5' --10" C � C--7 1P- - 1 STOREFRONT CELING CONFIGURATION W /ROLLING GRILL 4 _______________' I I GWB SOFFIT NOTE: GC TO ADJUST CORD LENGTH PER THE NOTED AFF HEIGHT OF EACH PENDANT LIGHT LIGHTING FIXTURE TRACK ATTACHED TO SLIDING LI BRACKET BEYOND GWB W/ #12x1 Y2" PANHEAD SH. MTL. SCREWS @ 2'--0" O.C. 5' -10" AFF rlll I I I I \ I 6' -3" AFF 5-7" AFF �. TRACK MOUNTING TO GWB 2 EQ EQ CENTER OVER HAND -OFF . HAND -OFF PENDANT LIGHTS NTS „ , Y —_1 „ PLAN STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION, ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 I RL.GISTE D :HjTECT STATE OF WASH E 741 Docrer Ayoone No »6 4/301 Seattle, WA 99109.4342 t: 706.245.4300 I: 206.255.4371 w: •ww.olywpIcassooIotes.com OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION co co rn Y H F - - ” 0 0 STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE CEILING & LIGHTING DETAILS Ir.r SCALE: VARIES c3 (DO NOT SCALE DRAWINGS) SHEET NUMBER A3.2 P"'"T SOUTHCENTER II 1047 SOUTHCENTER MALL STARBUCKS COFFEE KING COUNTY PERMIT CENTER 9101 0 GROUT — GREY MAPEI #47 CHARCOAL --F MIME EPDXY GROUT AVAILABLE IF NEEDED 179263 GC 9109 0 GROUT — IVORY MAPEI #39 IVORY KERAPDXY tI■ 11 EPDXY GROUT 425120 GC B012 16 TILE INTERIM3 DIAMANTE 12X12 PASTORELLI CERAMICHE TECNOSTONE, DIAMANTE --F MIME (BOX OF 18 TILES) — USES B1O1 GREY GROUT 179263 3PL B143 8 TILE 12X12 BKBR LRV DIMODA 20/ ASSOCIATED IMPORTS SAN WON OLIVE /LTGRN /ICE tI■ 11 (20 TILES PER BOX) —USE B109 IVORY GROUT 425120 3PL 8050 5 TILE BIANCO BASE 6 "X12" PASTORELLI CERAMICHE TRADIZIONAL E, BIANCO --F MIME (BOX OF 24 TILES) --- USE B101 GREY GROUT 179252 3PL B053 10 TILE NERO BASE PASTORELLI CERAMICHE TRADIZIONAL E, NERO tI■ 11 (BOX OF 24 TILES) — USE 8101 GREY GROUT 179251 3PL ADL10 1 TILE FLOOR TBD --F MIME LOCALLY SOURCED TILE 788 SQ FT +10% OVERGC i■ GC SALES SEATING ADL 10 FLOOR TILE B101 FLOOR GROUT B053 BASE AT FLOOR B101 BASE GROUT 000000 FLOOR FINISH PLAN 0 BACKBAR ADL 10 FLOOR TILE B101 FLOOR GROUT B053 BASE AT FLOOR B101 BASE GROUT 0000000 FLOOR FINISH SCHEDULE: FLOOR FINISH KEY 0 FLOOR COVERINGS SCHEDULE: ITEM# QTY DESCRIPTION MANUFACTURER MODEL # REMARKS SKU # SHIP CERAMIC TILE TILE EASE GROUT ADDITIONAL ITEMS WORKROOM 8012 FLOOR TILE B101 FLOOR GROUT B050 FLOOR BASE B101 BASE GROUT 000000 NOTES: O ALL FLOORING AND BASE MATERIAL TO BE INSTALLED ACCORDING TO STARBUCKS SPECIFICATIONS. O DIE WALL BASES TO BE SET BEFORE TILE INSTALLATION. 0 FOR ALL TILE AND /OR VINYL BASE INSTALLATIONS AT CASEWORK, MECHANICALLY SAND AND SCARIFY WOOD SUBSTRATE TO COMPLETELY REMOVE ALL FINISH. TROWEL ON A PRIMER COAT OF MAPEI TYP 1, KER 903 ADHESIVE AND ALLOW TO AIR DRY. O NUMBER NOT USED PROVIDE GROUT JOINT OF 3 /g' MAXIMUM DEVIATION OF TILE AND GROUT LINE OF y4 PER 4'. O ALL TILE AND SLATE TO BE INSTALLED PER TILE COUNCIL OF AMERICA STANDARDS. 07 TILE BASE AND THRESHOLD GROUT JOINTS TO ALIGN WITH TILE FLOOR GROUT JOINTS. O REMOVAL OF EXCESS GROUT WILL BE DONE WITH WATER. THE USE OF SULFURIC OR MURIATIC ACID IS PROHIBITED. IF THESE ACIDS ARE USED, THE INSTALLER WILL BE REQUIRED TO REMOVE THE ACID AND RESTORE THE GROUT AT THEIR EXPENSE. O TILE START POINT WHERE INDICATED. 10 FLOOR SINK /FLOOR DRAIN LOCATION. 0 SEE SHEETS A5.0 & A5.1 FOR BACKBAR WALL TILE LAYOUT. RECEIVED CITY OF TUK \N LA FEB 082008 I'LL-WIT CENTER STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 a r� REOIS FRED F ' r. HILECT _ . VA STATE OF WA 701 Dexter Aveaoe 0ori8 #301 544111e, WA 98109.4313 t: 206.285.4300 I: 206.285,4371 •: www.elymplcossocIotes.COm Ala OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION z 0 U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE FLOOR FINISH P LAN & SCHEDULE SCALE: 114 =1 -0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A4.0 P"'"T SOUTHCENTER 11 1047 SOUTHCENTER MALL TUKWILA, WA 98188 STARBUCKS COFFEE KING COUNTY --F MIME -° i■ . 1111ii11■ 1111 - ■ tI■ 11 - 1111 0 j ■ 0 ■ ■■■ ° wo to mow 00 ■ 0 0 NM 1 D ■ ■ ■11ifi ■ ■ ■I■ ■■ ■■EN ■!K 7 a op o ■ • ■ ■r 0 0 -01_ 1111■■■ ■ ■ ■■ ■ I o o ►i o t■ ■ ■ 00 ■ ■ ■ ■ ■ ■ ■■ ■1111 ■ ■■ ■ ■ ■ ■!1 ■ ■ ill ■■ ■■ ■ ■ ° ■ ■ \!1 ■WM. ■1! -,- o • 0 o 0 oil] ■ P ill ■ ■ III 111111111111111111111 ■ ■ ■ ■ ■ ■■ ■ ° ■1111 ■ ■! ■■■■■ ■ ■ ■ o a o a ■1111■ } I 1H ■ 1�1 o j I _ ■ ■■� ■ ■ ■■ I IS■ a a n o o• Ai• !! ! !l i ■ ■■ ■ ■ ■■■■ ■■ ■ ■ ■ ■ • ■■ i °D 0 a � ■ ■ ■ ■ ■ ■ ■■ ■■■ ■11 11■■■ ■ ■ ■ ■ ■ ■■ ■■ 1111.111 4000000000 L.. s�- ■ ■ a o o 011 1 .�...--�.� EWE A4,1 � 111PI' W. II/00000000E1 1000000000 II a a o 0 0 I r■■i ■ ■ A . . ' 1 �11 � ■■I■ ■ MOM ■ ■ 1111 ■■ ■ 'd � ° ►00000000 ■ ■ ■■ ■ ■ , f l 00000000 0 I .■ Mil ■ ■■m■11■■ __ __ ■ ■ ■ ■ ■l1 Si e ■ ■ ■�tl • 0000000• I ■ I A4.1 MK 0000000 111111111 �a 1111 0 o ■� 0 0 0 0• r 1 o ^ o I I I PliPil ■ ■I■ ■ ■ ■■■ 11 ■ ■ t1 li ° d o T° 0 a 0 a• ■ ■ /I ■r ■1 h■■■■■ ■ ■ ■ ■ ■ ■ ■ ■Ld l0000000 I r \ ■ a o 0 0• ■ ■/1 ■ ■■I� IN ■r ■ ■ ■ ■t 1a 0 0 ■� 1 .I ■ ■1 ■■ ■Iii ■■ L Ili ■I 1111 ■ ■ ■ ■II , o 0 0 0 0 o a �■ ■■■ -II 1111 ■ ■■ ■ ■1 1 0 0 0 0 0 0 • ; 'ffliallill ■ii ■■ -- ■■■■ ■■1 n] 0 0 0 0 0 0 ----I i lUUUlU ■Qi ■ ■NL lo 0 0 0 0 0 �UU!U' o o 0 0 0 • I SALES SEATING ADL 10 FLOOR TILE B101 FLOOR GROUT B053 BASE AT FLOOR B101 BASE GROUT 000000 FLOOR FINISH PLAN 0 BACKBAR ADL 10 FLOOR TILE B101 FLOOR GROUT B053 BASE AT FLOOR B101 BASE GROUT 0000000 FLOOR FINISH SCHEDULE: FLOOR FINISH KEY 0 FLOOR COVERINGS SCHEDULE: ITEM# QTY DESCRIPTION MANUFACTURER MODEL # REMARKS SKU # SHIP CERAMIC TILE TILE EASE GROUT ADDITIONAL ITEMS WORKROOM 8012 FLOOR TILE B101 FLOOR GROUT B050 FLOOR BASE B101 BASE GROUT 000000 NOTES: O ALL FLOORING AND BASE MATERIAL TO BE INSTALLED ACCORDING TO STARBUCKS SPECIFICATIONS. O DIE WALL BASES TO BE SET BEFORE TILE INSTALLATION. 0 FOR ALL TILE AND /OR VINYL BASE INSTALLATIONS AT CASEWORK, MECHANICALLY SAND AND SCARIFY WOOD SUBSTRATE TO COMPLETELY REMOVE ALL FINISH. TROWEL ON A PRIMER COAT OF MAPEI TYP 1, KER 903 ADHESIVE AND ALLOW TO AIR DRY. O NUMBER NOT USED PROVIDE GROUT JOINT OF 3 /g' MAXIMUM DEVIATION OF TILE AND GROUT LINE OF y4 PER 4'. O ALL TILE AND SLATE TO BE INSTALLED PER TILE COUNCIL OF AMERICA STANDARDS. 07 TILE BASE AND THRESHOLD GROUT JOINTS TO ALIGN WITH TILE FLOOR GROUT JOINTS. O REMOVAL OF EXCESS GROUT WILL BE DONE WITH WATER. THE USE OF SULFURIC OR MURIATIC ACID IS PROHIBITED. IF THESE ACIDS ARE USED, THE INSTALLER WILL BE REQUIRED TO REMOVE THE ACID AND RESTORE THE GROUT AT THEIR EXPENSE. O TILE START POINT WHERE INDICATED. 10 FLOOR SINK /FLOOR DRAIN LOCATION. 0 SEE SHEETS A5.0 & A5.1 FOR BACKBAR WALL TILE LAYOUT. RECEIVED CITY OF TUK \N LA FEB 082008 I'LL-WIT CENTER STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 a r� REOIS FRED F ' r. HILECT _ . VA STATE OF WA 701 Dexter Aveaoe 0ori8 #301 544111e, WA 98109.4313 t: 206.285.4300 I: 206.285,4371 •: www.elymplcossocIotes.COm Ala OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION z 0 U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE FLOOR FINISH P LAN & SCHEDULE SCALE: 114 =1 -0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A4.0 P"'"T SOUTHCENTER 11 1047 SOUTHCENTER MALL TUKWILA, WA 98188 STARBUCKS COFFEE KING COUNTY 20 19 18 16 14 +13 • I 0 � 9 ,.- a 1 \-- - .. . ,,,,, 6 r _.. . --_.., . _ _,L.,„_;=•-------- $ ► 5 B 11 BULLNOSE SANITARY VE •--- - i t • , . : ;, n = r r w E I FRP FINISH PANEL 3 /8" COVED TILE BASE NOTE: MECHANICALLY SAND AND SCARIF WOOD SUBSTRATE TO COMPLETELY REMOVE ALL FINISH. TROWEL ON A PRIMEF COAT OF MAPEI 'TYPE 1, KER 903' ADHES AND ALLOW TO AIR DRY. APPLY NOTCHE TROWEL COAT OF KER 903 ADHESIVE AND INSTALL TILE PER SPECIFICATIONS. AND TYP DIE WALL '- � BULLNOSE SANITARY 3 /8" COVED TILE BASE BULLNOSE SANITARY 3 /8 " COVED TILE BASE PLASTIC SHIM (IF REQ'D) m�ummmmurrnnrr��rrumnr TILE BASE VIEW LAN -� TILE FLOORING WOOD FINISH. 1, KER DIE WALL TILE FLOORING ���������� �� NOTE: MECHANICALLY SAND AND SCARIFY SUBSTRATE TO COMPLETELY REMOVE ALL TROWEL ON A PRIMER COAT OF MAPEI ' TYPE 903' ADHESIVE AND ALLOW TO AIR DRY.APPLY NOTCHED TROWEL COAT OF KER 903 ADHESIVE AND INSTALL TILE PER SPECIFICATIONS. TILE BASE @ .�suMNrnmmmun T ILE BASE @ TNT WALL SCALE = 3" = 1 " INTEGRAL ' , „ = I WO SECTION 3 = 1 -0 SECTION STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 REGISTERED ARCHITECT ) 1 1 0 " $1111 JEAN BARTHOLME OF WASHINGTON 7 0 1 D i i Avenue North #301 Seattle, WA 98109.4342 t: 203.285 -4300 I: 206.285.4371 wvra.ol9mpi rossociates.rov. OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION I- 0 U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE FLOOR FINISH DETAILS RECEIVED CITY OF TE ; (v FEB 0 8 200E SCALE: VARIES PERMIT CENT (DO NOT SCALE DRAWINGS) SHEET NUMBER A4.1 ILA ER G717 1 MENU BEAN RISTRETTO PATTISON SIGN DIMODA 2 PANEL W/ WOOD FRAMES 185417 3PL G718 1 MENU BOARD BEV MSS CASEWORK MT PATTISON SIGN 3 PANEL BEV CASEWORK MNT 3 PANEL W/ WOOD FRAMES 190993 3PL G726 1 MENU BOARD DO MSS CASEWORK MT PATTISON SIGN DAILY OFFER CASEWORK MNT 226324 3PL G913 1 BULLETIN BOARD MAGNETIC VERT IVEY DIGITAL VERTICAL 187511 3PL DA13 1 DA13 PAPER BLOCKS COFFEE SHO DISPLAY PRODUCTS DIMODA TODD KARAM "COFFEE SHOP" 192463 VD DA19 1 DA19 PAPER BLOCKS GRW /RST /BRWRODUCTS DISPLAY DIMODA ROBERT MERCER "GROW /ROAST /BREW" 1929.69 VD GENERAL PAINT NOTES: A. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. B. TO LOCATE THE NEAREST SHERWIN WILLIAMS STORE, CALL (800) 321 -8194. ORDER PAINT BY STARBUCKS COFFEE COMPANY PROGRAM "COLOR CODE ". PAINT FORMULAS FOR "COLOR CODE" AVAILABLE AT (800) 321 -8194. FURTHER INFO AVAIL. THRU ED STEIN AT 509 - 994 -6394. C. SUBMIT TWO (2) SETS OF 8Y2" X11" BRUSH -OUTS OF ALL PAINT COLORS AND FINISHES TO THE STARBUCKS CM FOR APPROVAL PRIOR TO PAINTING. D. REFER TO INTERIOR ELEVATIONS FOR COLOR LOCATIONS. E. ALL WOOD AND METAL SURFACES SHALL BE PAINTED SEMI - GLOSS, UNLESS OTHERWISE NOTED. F. WALL RECEIVING VINYL MURAL WALLCOVERING SHALL BE SMOOTH AND PVC PRIMED. MURALS TO BE SEALED. SEALER IS PROVIDED WITH MURAL. STOREFRONT WALL FINISH PLAN PAINT & WALL TREATMENT SCHEDULE: COLOR / MATERIAL CODE P832-E /S P835 -E /S P836 -E /S P842 -E /S P830- -S /G P832 --S /G P842 -S /G CP -1 CP -2 CP -3 FRP1 DESCRIPTION GENERAL FIELD COLOR (USE CP -1 PRIMER) ACCENT WALL (USE CP -3 PRIMER) ACCENT WALL (USE CP -2 PRIMER) CEILING USE CP -1 PRIMER) ACCENT & TRIM (USE CP -1 PRIMER) ACCENT & TRIM (USE CP -1 PRIMER) CEILING (USE CP -1 PRIMER) PRIMER PRIMER PRIMER WORKROOM MATERIAL PAINT PAINT PAINT PAINT PAINT PAINT PAINT PRIMER PRIMER PRIMER .090 FRP MANUFACTURER SHERWIN- WILLIAMS SHERWIN - WILLIAMS SHERWIN - WILLIAMS SHERWIN - WILLIAMS SHERWIN- WILLIAMS SHERWIN - WILLIAMS SHERWIN - WILLIAMS SHERWIN - WILLIAMS PREPRITE 200 PRIMER B28 SHERWIN- WILLIAMS PREPRITE 200 PRIMER B28 SHERWIN-- WILLIAMS PREPRITE 200 PRIMER B28 MARLITE LIGHT REFLECTANCE VALUE LRV= 70 LRV =34 LRV =17 LRV =52 LRV =86 LRV =70 LRV =52 N/A N/A N/A P -100 WHITE HARMONY EGGSHELL "EBLUE" HARMONY EGGSHELL "ORANGE POP" HARMONY EGGSHELL "SCOOTER RED" HARMONY EGGSHELL "DI NEUTRAL" PRO MAR 200 SEMI -GLOSS "WHITE ON" HARMONY SEMI -GLOSS "EBLUE" HARMONY SEMI -GLOSS "DI NEUTRAL" COLOR PRIME SYSTEM P -1 COLOR PRIME SYSTEM P -2 COLOR PRIME SYSTEM P -3 FULL HEIGHT IN WORKROOM INCLUDING MOP SINK GRAPHICS SCHEDULE: GRAPHICS SCHEDULE: ITEM# QTY DESCRIPTION MANUFACTURER MODEL # PHOTOS /STAMPS MENU BOARDS ACCESSORIES BANNER - COMING SOON 3'X8' F3A F - NOW OP EN 3'X8' DISPLAY PRODUCTS DISPLAY PRODUCTS REUSABLE VINYL RFLJSAF3I F VINYL poi -o75 104004 NOTES: ti 4Ub.5 3 SEE CASEWORK PLAN ON SHEET A7.0 FOR STOREFRONT PANEL SYSTEM �4 SEE CASEWORK PLAN ON SHEET A7.0 FOR WAINSCOT SCHEDULE. 0 INSTALL METAL CORNER GUARDS AS INDICATED. MOUNT © 6" AFF. AFFIX WITH #6 STAINLESS STEEL OVAL HEAD SCREWS 3" FROM ENDS, 12" OC OFFSET SCREWS ON EITHER SIDE BYE" VERTICALLY 0 PROVIDE AND INSTALL FULL - HEIGHT FRP @ MOP SINK ENCLOSURE AND ALL WORKROOM WALLS 0 FOR WALL TILE SCHED. SEE SHEET A4.0 a CASEWORK PANELS MOUNTED AT REVEAL IN 6 "L" COLUMN INSTALL FRY REGLET CORNER TRIM PIECE AS NEEDED IN FRONT OF HOUSE WHERE DRYWALL TO DRYWALL OUTSIDE CORNERS EXIST WITHOUT WAINSCOT PROTECTION. ITEM IS GC SUPPLIED AND INSTALLED DURING DRYWALL TAPING PROCESS. TRIM PIECE CAN BE FIELD PAINTED. IF TO BE PAINTED, GC TO REQUEST DMCT --1250 WITH CHEM FILM, A PAINTABLE SURFACE APPLIED BY THE SUPPLIER AT NO ADDITIONAL COST. C8 USE EPDXY PAINT SPEC AT BOTH MERCH WALLS 09 STOREFRONT CASEWORK SYSTEM WALL TREATMENT KEY: INDICATES WAINSCOT STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD SHEET TITLE 731 owe! Aveoue Hr h #301 Seellle, WA 93109.4343 406.735.4300 I: 406.705.4371 •: tw .a Iymplrussu[Iule i. r oq AMIL OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION w w U- o f2 w LU cc H- u) 0 CO 0 w -7 0 IID I— 0 0 STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME WALL FINISH PLAN & SCHEDULESE' o we SCALE: I 14 =1' -0" v (DO NOT SCALE DRAWINGS) SHEET NUMBER A5.0 U 0 1. P832 -S /G ELEVATION @ BACKBAR P835-S /G ELEVATION @ FRONT OF STORE ELEVATION @ FRONT OF STORE P841-- -S /G ,■ ■ ■ ■_ ■ ■ ■ ■r ■ ■ ■ ■ ■� _ ■ ■■ ■■ . ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■I ■I MEMMEMEMEMMEMMEMMEMMEMMEMMIMMINMEMIMMERMEMEAMMMI MMEMMEMMEMMEMMEMMEMMEMMEMMEMMEMMEMMEMMEMEMEMMEMMI ■■■■EMEM=M �CMMEMME■ME■EM ■■■ ■■■■■■■■■■■■IrMEMM■■■ ■L— a.� 1 MO UM ■■■■ �� IIIMU MIIM■■=■•N■= ■!■1!' ■!I ■IF ■1!1 ■1!9■■■■■■M■■■■ ■ ■� ■r■■ ■■■■Emr 1 G 'c 1■■■ mu■m■Em ■■■ ■■■■■■Mm I ■ii■NR rear !1 ■ ■ ■ ■ ■MM■■■l ■■ ■■■■ ■ � ■ ■ ■EMEM ti I 2 E:I ■ ■■ � ■� ■� ..�.. M ..� ■ ■ ■ ■�!1■�1■II I ■!�I ■111 ■ally ® 11 ■ ■ ■ ■Ll mmml ■ ■ ■ ■ ■■ ■■■■NE■■I�i ��i bib WIMEM■■�II■l�m�IImE ■In�ll ■111 1 ■ ■ ■ ■ ■■ ` i I 7 ���I(r rrrnrrir�anl��� ■ ■r _I_� ==IM___11 ■ X 11 ISEE I 11 �` " '—' L � � *� S P832 -E /S ALL SIDES • P836 -E /S P836,--E/S e .4. -.- P832- E /SI- -+ I EQ / T I I I T f __J t T I I P842 -S /G P836 -E /S P836 -E /S P841 -S /G A ELEVATION @ MERCH WALL P832 -E /S DA19 DIMODA ARTWO ROAST, B OBLIQUE ELEVATION @ SIDE OF BACKBAR Q ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS, UON. O REFER TO MANUFACTURER'S INSTRUCTIONS SHIPPED WITH ARTWORK FOR INSTALLATION INSTRUCTIONS AND SPACING. O INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE. RUN BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS, NOT BEHIND CABINETS. O PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. REFER TO WALL DA13) FINISH PLAN FOR PAINT SCHEDULE. P841 -S /G NOTES: O STOREFRONT PANEL SYSTEM STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION, ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 R EGI S TERED r' 1 EC LEAN EAR'i HOLME F WASHINGTON 701 0e4191 Avenue Hoot 8381 Seattle. WA 98189.4342 t; 786.785.4388 f: 186.285.4371 wa.ol7mpico ssooi o t as. com OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION z 0 0 STnRF #• 1 4777 FKO' #: 12197 -001 EgI@dFCT #80 1 1 IG'T: dl1'g1QE PRNT I AWItTE: OJ94119DA IUE DATE: ROYMIVItieNG RBI: M al55 QI CKED: SOMBIWIROMRE MECKED: DIMJ QAC CHECK: Vigta1E NAICHOM SHEET TITLE INTERIOR ELEVATIONS CY LLI W I- ()W wo SCALE: 3 / 8p' =1 (DO NOT SCALE DRAWINGS) SHEET NUMBER A5.1 1 KG913 P832 -S /G ELEVATION @ BACKBAR P835-S /G ELEVATION @ FRONT OF STORE ELEVATION @ FRONT OF STORE P841-- -S /G ,■ ■ ■ ■_ ■ ■ ■ ■r ■ ■ ■ ■ ■� _ ■ ■■ ■■ . ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■I ■I MEMMEMEMEMMEMMEMMEMMEMMEMMIMMINMEMIMMERMEMEAMMMI MMEMMEMMEMMEMMEMMEMMEMMEMMEMMEMMEMMEMMEMEMEMMEMMI ■■■■EMEM=M �CMMEMME■ME■EM ■■■ ■■■■■■■■■■■■IrMEMM■■■ ■L— a.� 1 MO UM ■■■■ �� IIIMU MIIM■■=■•N■= ■!■1!' ■!I ■IF ■1!1 ■1!9■■■■■■M■■■■ ■ ■� ■r■■ ■■■■Emr 1 G 'c 1■■■ mu■m■Em ■■■ ■■■■■■Mm I ■ii■NR rear !1 ■ ■ ■ ■ ■MM■■■l ■■ ■■■■ ■ � ■ ■ ■EMEM ti I 2 E:I ■ ■■ � ■� ■� ..�.. M ..� ■ ■ ■ ■�!1■�1■II I ■!�I ■111 ■ally ® 11 ■ ■ ■ ■Ll mmml ■ ■ ■ ■ ■■ ■■■■NE■■I�i ��i bib WIMEM■■�II■l�m�IImE ■In�ll ■111 1 ■ ■ ■ ■ ■■ ` i I 7 ���I(r rrrnrrir�anl��� ■ ■r _I_� ==IM___11 ■ X 11 ISEE I 11 �` " '—' L � � *� S P832 -E /S ALL SIDES • P836 -E /S P836,--E/S e .4. -.- P832- E /SI- -+ I EQ / T I I I T f __J t T I I P842 -S /G P836 -E /S P836 -E /S P841 -S /G A ELEVATION @ MERCH WALL P832 -E /S DA19 DIMODA ARTWO ROAST, B OBLIQUE ELEVATION @ SIDE OF BACKBAR Q ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS, UON. O REFER TO MANUFACTURER'S INSTRUCTIONS SHIPPED WITH ARTWORK FOR INSTALLATION INSTRUCTIONS AND SPACING. O INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE. RUN BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS, NOT BEHIND CABINETS. O PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. REFER TO WALL DA13) FINISH PLAN FOR PAINT SCHEDULE. P841 -S /G NOTES: O STOREFRONT PANEL SYSTEM STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION, ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 R EGI S TERED r' 1 EC LEAN EAR'i HOLME F WASHINGTON 701 0e4191 Avenue Hoot 8381 Seattle. WA 98189.4342 t; 786.785.4388 f: 186.285.4371 wa.ol7mpico ssooi o t as. com OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION z 0 0 STnRF #• 1 4777 FKO' #: 12197 -001 EgI@dFCT #80 1 1 IG'T: dl1'g1QE PRNT I AWItTE: OJ94119DA IUE DATE: ROYMIVItieNG RBI: M al55 QI CKED: SOMBIWIROMRE MECKED: DIMJ QAC CHECK: Vigta1E NAICHOM SHEET TITLE INTERIOR ELEVATIONS CY LLI W I- ()W wo SCALE: 3 / 8p' =1 (DO NOT SCALE DRAWINGS) SHEET NUMBER A5.1 20 19 18 D OO7 .........015 � WATER HEATER - li�I� � INTERACTIVE ��� . n CHATSWORTH PRODUCTS #1532 1 -5 24 HEAVY DUTY -MOUNT EQUIPMENT RACK CHATSWORTH PRODUCTS BUTYL RUBBER CAULK - �- ` / / ALIGN � I LINE OF CEILING z s° RACK SECURED SHELVES ARE TO SOLID BLOCKING EVENLY SPACED I PLYWOOD FLOOR =' y GLASSCRETE CEMENT OARD / / ?" \ ALARM PANEL WIRELESS III _ - SHELVING 3% (2) 3/g 16 GAL» STUDS TYP W /8 GWB EACH SIDE (2) 6" 16 GA MTL JOIST TYP W/ 4Y2 X 12 PANHEAD � �a ; =�WALL =I I 16 GA. MTL. STUD �� 1 l J / /� i INTERNET HUB i ' TO BLOCKING pASEWpRK PANEL ,., �� VINTERUPTIB -i POWER SUPPLY I I TUB TO MATCH DI MODA WAINSCOT FINISH METAL BOLT \\_, CONNECTION i� ^' `� SECURITY RECORDER SECURITY MONITOR `i MANAGER'S CPU LAN HUB & ELECTRONIC EQUIPMENT RACK ¢ I � -( \\ SHEET MTL SCREWS W/ WASHERS TYP. ALIGN JOIST / WATER HEATER PLAN VIEW \ 5/$„ GWB FRP \ \ m (4) 1 N � � . e EQUIP #40074 -500 SINGLE -SIDED SHELF, TYP. N OTE: BOTTOM TWO SHELVES ARE INSTALLED w/ BRACKETS RACK „ W FEET o - �i�.�� - - ,. = ` ��� MONEY CO UNTER J BLDG LID ABOVE � 11.. (I FILE �I CABINET » 1Y2 16 GA. STRAP OR Y2' ELECTRICAL CONDUIT ANCHOR TO WALL WITH MINIMUM %6 X 3Y2 LAG BOLTS SHELF -FRP @ ALL FACES CEILING TILE - OPEN FOR HOT WATER HEATER IF REQUIRED ���'/'�� FRP @ MOP SINK �� SECTION I �1 BEAM PANEL - � .__. 2'-0” KEYBOARD MIN. CLR. PC MONITOR AND TRAY PRINTER MANAGERS . . DESK ELEV WATER HEATER DRIP PAN W/ DRAIN ■ 1Y2» - 1 1 _0" SECTION • W/CASEWORK SCALE - 3 /8 " = 1 - O " SCALE: NTS TO SINK BELOW KEEP AREA CLEAR FOR CLICK -SAN DISPENSER. SEE ADDITIONAL FOR LOCATION, CONFIGURATION, MOP HOLDER - MOUNTED TO GREEN BOARD OR SIMILAR I SIDF\WALL / ` / SCREW MENU HINGE TO TOP OF CABINET. ALIGN PIANO JOINT TO CABINET EDGE I NI 7'-10" - TOP OF CABINET HINGE • \ / -- Z <4 �N, ��Q` '& � v ,/ Q' e= . -- F _ `., - ° - \ a I N CD `r' \ \ GWB PAINT PER ELEVATION " " " = OVER MTL STUDS. TO BE ;.; , .. CAULK N N: FLUSH W /GWB WALL FACE �;. I 3 „ » /a X 1 WOOD TRIM PAINT TO MATCH WALL ABOVE AND INSTALLATION INFORMATION. I� 1 .I \ USE WINGNUTS AT BRACKET BACKBAR WALL TILE U �� 5 /" GWB WALL , C _ T . ., :; ± _ °"` ° "' • FAUCET , MOUNT TO ADJUST VERTICAL /f 3 4 " I 2'-9" +/- AF LINE ALL FACES OF GROUT SH IM ; I$ HEIGHT OF MENU AS NEEDED 6' -1" AFF - BOTTOM OF MENU ENCLOSURE W/ FRP .' -1.— N i „ 6 - 0 AFF . z �� A :.. ; .: . - `. A 0. ' Y SOLID SURFACE OPEN AREA BEHIND • SOLID SURFACE I MENU BOARDS ARE HINGED TO " CAULK ';' : , -. -- ALLOW A LL W ACCESS TO CABINET SHELVES BEHIND MENU HOSE CLIP � MOP SINK ( I I WALL TILE ATTACH PLASTIC STOPS TO CABINET VERTICAL EDGES (SUPPLIED BY CASEWORK VENDOR) 3 �� -__ -' 2'_0" A5.4 Y" GREEN BOARD ` - ' MOP SINK / ELEVATION DOUBLE HEIGHT STORAGE CABINET AT BACK BAR WALL CASEWORK MENU MOUNTING WALL TILE @ TRANSITION WALL TILE @ BACKSPLASH SOLID WOOD CHAIRRAIL ATTACHED TO WALL W/ CONSTRUCTION ADHESIVE & NAIL @ 24" SPACING. FILL ALL NAIL HOLES Y" WOOD VENEER Pp,� EL 6 1 -0 3" = 1' -0" SOLID SURFACES 8 3/4 '' = 1' -O" SECTION Y" = 1' -0" ELEVATION SECURE TO WALL W CONSTRUCTION Y" WOOD VENEER PANEL - SECURE TO WALL W/ CONTRUCTION ICE KEEP AREA CLEAR FOR CLICK -SAN DISPENSER. CLEARANCE MACHINE " ADHESIVE, SKIP TROWEL KADET -AF CLEANER 1' -6" - ALLOW FOR MIN 5 1 1/2 / BETWEEN RIGHT SIDE 5" 11" CHEMICAL DISPENSER -MOUNT TO BACK WALL OF MOP SINK SURROUND KADET -AF CLEANER / 6" --SEE ADDITIONAL DETAILS FOR LOCATION, CONFIGURATION AND INSTALLATION INFORMATION 1 -10 3 OF MACHINE OBJECT 2' -10" AND ANY ADJACENT CLICK- SAN /WASH /WALL FOR VENTING DISPENSER ALIGN BOTTOM OF DISPENSER W/ TOP OF FULL HT. CHEMICAL CONTAINER BRACKETS, TYPICAL CLICK -SAN CLICK-WASH CHEMICAL - - „ „ J CHANNEL SUPPLIED BY GC. a - �° - Y MAX GAP I ADHESIVE, SKIP TROWEL / " SOLID WOOD VERTICAL TRIM - ATTACH TO WALL W/ CONSTRUCTION l / ��' / 4 / / — i�l a ��" SECURE TUBING 24" WIRE SHELF KIT �. — FRP �_ r _. W/ ZIP -TIES POSITION OVER SINK DRAINBOARDS E I F �c >, 4x3 - EST STRIP BOX t _ CHEMICAL -MOUNT BRACKET ON CLEANER W DISPENSER OF ADHESIVE & NAIL @ 12". FILL ALL NAIL HOLES - � 'c N I 8 9 I N CLEAN --- DRAINBOARD ,- � I �, F, 4 l I in ' 4'-.. 9 *t! I NI M'1 + I t� - 3/8 " C4 I ° // U \\ u DIRTY DRAINBOARD INE SANITARY - COVE TILE BASE TILE FLOORING ' - orrummmmr 0-:--s •-i) " 3-COMP SINK L r FAUCET WATER HOSE • O FRESH MOP SINK BASIN a 1- - \ CLEAN DIRTY BASE TRIM OUTLINE (BELOW) WOOD WAINSCOT VERTICAL TRIM SECTION SANITIZER ALWAYS o ON RH 'CLEAN' SIDE -MOUNT C THE `t WAINSCOT W/ TOPSET BAS ii i "DIRTY" SIDE ONLY. \ a WORKROOM - 18" WIRE SANITIZER COMPARTMENT SINK ROLLING CART ON 4" GT WORKROOM SINK @ " - SECURE TUBING TO WALL ABOVE SINK BACKSPLASH WITH ZIP-TIES. -MOUNT TEST STRIP BOX TO WALL OVER THE "CLEAN" DRAINBOARD. CLICK-SAN/WASH INSTALL M075 KADET MOUNTING N SCALE = 3 /$ „ = 1 -O" I SCALE = 3 /g = 1 -O 6 "= 1' -0" SECTION 3 "= 1' -0" SECTION 3 /4" = 1' -0" ELEVATION STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 " : T ERED l rE c itA, V LE • JEAN BARTHOLME S TE OF WASHINGTON 701 Oexrer Avevue North #301 Seville, WA 98109.4342 I. 206.785.4300 I: 206.285.4371 w, www,plymplpps,pdples.[pm OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE WALL FINIS DETAILS SCALE: VARIES (DO NOT SCALE DRAWINGS) SHEET NUMBER A5.2 UPPERCABINETPLAN CASEWORK PLAN 0.11 0 2 17:1:7 1.. ••• 12 CASEWORK FINISH SCHEDULE: DESCRIPTION SOLID SURFACE COUNTERTOPS SOLID SURFACE COUNTERTOPS SOLID SURFACE COUNTERTOP STAINLESS STEEL COUNTERTOPS BUTCHER BLOCK COUNTERTOPS WOOD CASEWORK FINISH WOOD CASEWORK FINISH MELAMINE CASEWORK EXTERIOR MELAMINE CASEWORK INTERIOR MELAMINE CASEWORK INTERIOR STEEL BRACKETS STEEL RAILING AND MISC HARDWARE SNEEZE GUARD SNEEZE GUARD HARDWARE SWITCHPLATE FOR DUPLEX OUTLET MANUFACTURER DUPONT DUPONT MB WELLINGTON LITEBLOCKS PIONITE WILSONART WILSONART DUPONT TIGER DRYLAC CR LAURENCE BALDWIN 1 -800— 358 -2469 EXT 111 u I I d II H 1 �V124)BELOW "SAHARA" SEMI—GLOSS MAPLE PLAIN SAWN EUROPEAN BEECH, SOLID PC133 WX421 —H WITCHCRAFT COLD ROLLED STEEL BLACK COLD ROLLED STEEL MATERIAL / FINISH #4 BRUSHED 16G. SS PLAIN SAWN EUROPEAN BEECH VENEER NATURAL ALMOND D30 -60 TEMPERED GLASS STAINLESS STEEL PART # 4752-150—CD SATIN NICKEL CASEWORK FINISH SCHEDULE: DIMODA (LRV) PALETTE WORKROOM LOCATION BACKBAR COUNTERTOPS & BACKSPLASHES CAFE CONDIMENT COUNTERTOP ESPRESSO BAR, CUSTOMER BAR, GRINDING STATION, BLACK APRON & POS, SIT HERE TABLE BACKBAR COUNTERTOPS & BACKSPLASHES HAND —OFF PLANE ESPRESSO & CUSTOMER BARS PARTNER WORK AREA COUNTERTOPS TASTING TABLETOP DAILY REMINDER ESPRESSSO & CUSTOMER BAR DIE — WALLS, CUSTOMER SIDE POS FINISH PANELS AND RETAIL WAINSCOT ESPRESSSO & CUSTOMER BAR TOP CAPS, CHALKBOARD SURROUND, WAINSCOT CAP AND CORNER GUARDS BACKBAR CASEWORK EXTERIOR, STORAGE CUBBIES, ETEGERE MERCH BAYS, CONDIMENT CART EXTERIOR, PREP AREA WAINSCOT BACKBAR CASEWORK INTERIOR CONDIMENT CART INTERIOR FACE PANEL BRACKETS FOOT RAIL, GALLEY RAIL, BLACK APRON, DAILY REMINDER, HAND —OFF BRACKET, COFFEE FLOOR STAND ESPRESSO•& CUSTOMER BARS SNEEZEGUARD HARDWARE OVER "ALMOND" OUTLETS IN BANQUETTE AND WAINSCOT LOCATIONS REMARKS/ V.D. CODE MA109 M T104 3 —COAT CLEAR VARNISH FLAT FINISH POWDER COATED "ROMAN BRONZE" MT102 GC SUPPLIED NOTES: 1Q STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY CASEWORK LISTED IN CASEWORK SCHEDULE (UON). 02 REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS. Q ALL CASEWORK BASE UNITS SHALL BE SET ON 3/4" NON — ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR. �4 SEE WALL FINISH PLAN FOR LOCATION, TAGGING, AND FINISH SCHEDULES OF APPLIED WALL TREATMENTS. 5® STARBUCKS CM TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. GC TO CONFIRM CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER 4 WKS AND 1 WK PRIOR TO SCHEDULED DATE OF DELIVERY. ® DO NOT CAULK TRASH RINGS TO COUNTERTOPS W0107 0 INSTALL OVEN SS COUNTERTOP AND BASE CABINET WITH Y2" GAP BETWEEN ADJACENT COUNTERTOPS. SEE WARMING DETAILS FOR HOLD DIMENSION. Q SEE A8.0 SHEET FOR BASE /LEGS INFORMATION 9 O SEE SHEET A1.0 & A1.1, ELEVATIONS, FOR STOREFRONT LAYOUT AND DESIGN 1 0 CASEWORK PANELS LINING INTERIOR OF "I" COLUMN MOUNTED WITH "L" BRACKETS. CASEWORK SCHEDULE: CASEWORK SCHEDULE: ITEM# DESCRIPTION COUNTERTOP COUNTERTOPS — CORIAN /LAMINATE C848 1 CORIAN TOP CONDIMENT STAND V318 1 SMALL FOOTPRINT CBS LH V320 1 SMALL FOOTPRINT BREWER LH V328 1 80" POS COUNTERTOP V336 1 OVEN COUNTERTOP RH V.355 1 108" CBS COUNTERTOP RH V380 1 12" BACKBAR FIT KIT TOP V400 2 PUMP SHELF V405 4 8 ' FRENCH CLEAT FOR CUBBIES ADDITIONAL ADL11 ITEMS CASEWORK PANEL AT I COLUMN CASEWORK SCHEDULE: STORAGE /FILLERS DESCRIPTION V141 2 2X2 UPPER STORAGE CABINET V1 42 9 1X2 UPPER STORAGE CABINET V145 1 2X2 UPPER W /HOOD CASE V465 1 15" UPPER STG CABINET FIT KIT V945 4 MERCH UNIT PUBLIC C947 1 CONDIMENT STATION V972 2 TABLE TOP — SIT HERE 10' WALLS/TRIM 0654 1 WAINSCOT VERTICAL TRIM MSS 0658 26.91 WAINSCOT PANEL & TRIM LF ACCESSORIES C9.37 1 BUMPER RAILS MSS V010 1 CHALKBOARD V020 1 ELIPTICAL HANDOFF LH V1 24 1 1X2 TEA CUBBIE W /METEL INSERT V143 1 COFFEE REMINDER FIXTURE V148 1 P05 FINISH FACE PANEL QTY 3 V402 3 CUP DISPENSER PANEL V421 1 29" CEX GRINDING TOEKICK V423 1 80" P05 TOEKICK V447 1 SNEEZEGUARD INLINE BAR LH LOWER CABINETS C934 1 FOOD BASE CABINET C935 1 FLEX CART V007 1 INLINE BARISTA DIEWALL LH V100 1 1X7 TALL STORAGE CABINET V101 1 2X7 TALL STORAGE CABINET V102 2 12" CABINET W /DRAWER V103 2 12" CABINET W /DOOR V104 1 12" TRASH CABINET V105 1 12 " DOOR W /BLOCKING V108 2 15" SINK CABINET V112 3 24" CABINET V117 2 29" P05 CABINET V131 1 CORNER CABINET V132 2 24" SINK CABINET V151 1 22" P05 BRIDGE CABINET V200 1 CEX GRINDER CAB & TOP LH V390 1 INLINE BARISTA 55 TOP MAIN LH V392 1 INLINE BARISTA SS TOP LH V396 1 INLINE HAND OFF PLANE LH COUNTERTOPS — STAINLESS SS CART TOP RECEIVED CITY OF TU, tI LA FEB 0 8 2008 PERMIT CENTER AL rc Ai ' 'r • ;OLME ATE OF WASHINGTON STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 REGISTERE f cr:HiTE9 701 Dexter Avenue Nonk 0301 seerlle. WA 98109 -4342 t: 206.285.4300 206.285.4371 w: so ww.alymploossaalates.com OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION 1- H z 0 0 STORE #: 14777 PROJECT #: 12197-001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE CASEWORK PLAN & SCHEDULES SCALE: 1 14 =1' -0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A7.0 20 19 g 16 e REMOVABLE FINISH 2 ' -8 / >� 2 —10 AFF (BACKBAR COUNTERTOP) / 6' -8" COUNTERTOP LENGTH _,--- CUSTOMER SIDE OF CASEWORK PANEL w/ ELECTRICAL CHASE BEHIND / CASEWORK PANELS re"= -- == ---- - - - - -- MELAMINE UNDERSIDE OF COUNTERTOP ADJ. ADJ. SHELF BASE CABINET ATTACHED TO DIE II' WALL WITH CLEAT s ` I �� WOOD BASE PANEL. CLIP —ON ATTACH TO STAINLESS STEEL LEGS @ CUSTOMER SIDE OF CABINET ONLY. STAINLESS STEEL LEG PUS STCRAGE a02 aEVAnON SYSTEM HOLE IN SIDE FOR ELEC. SUPPLY CONTINUOUS METAL 3i ANGLE MOUNTED TO -.i PLYWOOD WALL, UNDER vi ■ / �- �- �� m m �� P —LAM DRAWER FRONT ADJUSTABLE I I ON 3 /4" SUBSTRATE FINISHED PANELS - _ CLIP -ON TOE KICK TYPI F " ' � . 6" ADJUSTABLE METAL LEGS 1- 1 1 1 . H I I u TOE KICK w POS SECTION II I ... TT rr —I tT POS ELEVATION 3, . V-0" SECTION 14 SECTION ELEVATION O • ENDCAP STAINLESS STEEL o I r� ' FILLER PANEL �' PASTRY CASE REMOVABLE CABINET BACK (TYPICAL IN ' 111 _ FLOOR SINK ALL CABINETS) J I 1 1 F ; i :•: L 1 `' , WITH FRP (TYP.) S TOE KICK BELOW � • A 7.1 FINISH PANELS � � � � 1I L AI ;fir w � H II V P17 - FRONTBAR CASEWORK PLAN 8 Y" = 1' -0" PLAN 4 1 /2 '' 4 3/4 " EQ EQ 4 1 /4 '' 4 1 /4 4 " 1/4 " � CUP DISPENSERS MOUNTED ON CABINET END PANEL (NOTE ORIENTATION) SEE DETAIL 5/A7.1 - --' -- SAFE SCALE GRINDER ,„ / PHONE I f ICE BIN TOWER HOT WATER DISPENSER I ±E oa�a, ,A040 • M.. POS POS r1 �� PASTRY CASE / I X I X CENTER LINES OF MOUNTING BRACKETS „ '11 111 1 I r '' L� — —,771 I i ��� —J REFRIGERATOR BELOW DIPPER WELL / , STAINLESS \ - -J `r i SOLID SURFACE COUNTERTOP • ktNg 0 - ,\ noR AIDE rnl __I rI roaAlnc unr _ _ i 11! -- -- = rt N.) CD 0.0 ii � -a° ; �'- ° WIRE GROMMET IN COUNTERTOP I STEEL WORK \ SURFACE HAND OFF PLANE VERISIMO ml i A VERISIMO cunDT unr rs rail nni n — liE AITI unT — _TALL HOT____ I a Fiz iti 1011021 Il l I +± WPM L \ ,.. c n > F RO N T BAR C U P DISPENSER RECEIVED WOOD TOP CAP WIRE GROMMET NOTE: CITY OF TUK I A OPERATIONAL REQUIREMENTS INCLUDING FEB o 8 200$ FRONT BAR F F& E P LAN IN COUNTERTOP QIPMENT PLACEMENT IS CRITICAL FOR SMALLWARE /INGREDIENT PLACEMENT CENTER pEBMIT yt> = 1' -O" . PLAN 3 / 4 " = 1 ' -O „ ELEVATION STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD OLYMPIC ASSOCIATES COMPANY 701 Dexter Avenue Noah 1301 5sottle, WA 9B109 -4342 t: ?06.285.4300 I. 206,285 4371 w, ww..olympicossodatas.cem REV DATE PD DESCRIPTION w w LL. O 0 Q co w Z co 1.11 CO I— D 0 CO M U w 0 l a I- z 0 0 STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE CASEWORK DETAILS SCALE: 1 14 =V -0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A7.1 1047 SOUTHCENTER MALL TUKWILA, WA 98188 KING COUNTY 20 19 WIRE GROMMET IN COUNTERTOP SEAMED © COUNTERTOP BETWEEN EDGE — -/ WIRE GROMMET IN COUNTERTOP DROP IN STAINLESS STEEL ICEBIN -SEAL TO COUNTERTOP w/ NSF CERTIFIED ADHESIVE SEAMED EDGE © COUNTERTOP BETWEEN TAIO S - �""""' �I d'.?> o �� j , • r b % \ / I ' I ' 0 D SPENSER '' ITfIIIIITI I [M IM I `. F I 1 11111 '' 1114 I, I MI ril 0 • 11111111 11111 ( .± ILL!1.WILLLIw1 / \�\ i � \ I L � , \, HIGH RISE LABORATORY FAUCET �a r. 2'- 3" / CABINET OUTLINE ADJACENT COUNTERTOP BLENDER PITCHER RINSER FAUCET (REFERENCE ONLY) -PLACE CLOSEST TO BLENDER AREA - INSTALL BACKFLOW PREVENTER ADJACENT COUNTERTOP (REFERENCE ONLY) / / (BELOW) ADJACENT COUNTERTOP (REFERENCE ONLY) SCALE /WORKSINK LAYOUT IN SUPPLY LINE • CBS STATION EQUIPMENT LAYOUT DROP IN STAINLESS STEEL SINK /DRAINBOARD INSERT -SEAL TO COUNTERTOP w/ NSF CERTIFIED ADHESIVE 18 4„ -1 , -0 „ PLAN ,» = 1, -0„ PLAN 14 OUTLET FOR REFRIGERATOR INDIRECT DRAIN FROM OUTLET FOR FRAPP DATA JACK FOR QUAD ICEBIN (ABOVE) - DISPENSER, REFRIG. & TO FLOOR SINK FUTURE CUP LABELLER BOTTOM OF CABINET HAS A CUTOUT THAT QUAD OUTLET FOR BLENDERS FUTURE CUP LABELLER CW & HW FOR SINK CABINET BACK IS IS OPEN TO FLOOR CW & HW FOR SINK - - - -, � -� u ,_, INDIRECT DRAIN FROM DRAINBOARD (ABOVE) TO FLOOR SINK �a � O O O 7-' ^T i i J 1 � J I" I i J = N OUTLET FOR SCALE REMOVABLE CABINET LEGS . I �� 1 � ` � j i } i �� `I (BELOW) i L - `� ,`` IN r� 1 I -I II ADJACENT CABINET (REFERENCE ONLY) UNDERCOUNTER UNDERCOUNTER REFRIGERATOR REFRIGERATOR CABINET LAYOUT DRAIN INDIRECT FROM SINK BASIN (ABOVE) TO FLOOR SINK FLOOR SINK ADJACENT CABINET \ ,_J ', 1'-0" (REFERENCE ONLY) COUNTERTOP EDGE (ABOVE) FLOOR SINK j, 1' -3' COUNTERTOP (ABOVE) EDGE CBS STATION SCALE/WORKSINKLAYOUT � 4» - 11 - 0» PLAN 3 /4 » = ' -" PLAN 10 SEAMED EDGE © COUNTERTOP BETWEEN STATIONS WIRE GROMMETS DECK MOUNTED O 0 6 le i IN COUNTERTOP HANDSINK FAUCET SOAP DISPENSER /_ . , \ � \ \ , ' \ (// \` \\ \ `\ \\ \\ \ .. I. \``. /' // ‘,./ II II H n I . u h- '"'"` ` '- =_ ..,, = F I `. ; r, L , p F �'' �I Z/t 9 Z n • DIGITAL BREWER I N \ N Z' 9- Z - - - -„ 12" HIGH SIDE SPLASH EACH SIDE INTEGRAL TO STAINLESS COUNTERTOP / WAR SHU ING TLES .L _ I Itil R ` SEAL HANDSINK TOP TO ADJACENT COUNTERTOP w/ NSF CERTIFIED ADHESIVE WIRE GROMMET IN COUNTERTOP L PREP c; '" ':'. '. . " � i __ __ - ___ _ _T'T_ \ o 1 1/) \ \ LAYOUT ADJACENT (REFERENCE CABINET OUTLINE 4' -0" PLASTIC TRASH 'I ' DROP RING / ADJACENT COUNTERTOP 1' -3" INTEGRAL STAINLESS STEEL SINK BASIN CABINET OUTLINE (BELOW) / COUNTERTOP NOTE: ONLY) EQUIPMENT PLACEMENT OPERATIONAL REQUIREMENTS SMALLWARE /INGREDIENT IS CRITICAL FOR INCLUDING PLACEMENT ADJACENT COUNTERTOP - SILICONE IN PLACE / / COUNTERLAYOUT (REFERENCE ONLY ) f- HANDSINK (REFERENCE ONLY) TRASH COUNTER CABINET OUTLINE (BELOW) LAYOUT AREA CABINET (BELOW) • BREWER EQUIPMENT LAYOUT dJ 4 »= V---0,, PLAN 4 „ -1 -0 PLAN 3/4 »_ 6 PLAN 9 4 „_ 1 ,_ 0 » PLAN 0 INTERIOR OF CABINET REMOVE BOTTOM SPREADER BAR AFTER ATTACHMENT OF T QUAD OUTLET BOTTOM OF CABINET HAS A CUTOUT THAT 220V OUTLET CWF FOR WARMERS FOR BREWER FORTOFF BREWER CW & TW FOR SINK IS OPEN TO FLOOR DOOR FRAME TO CABINETS ADJACENT ATTACH DOOR 4 _ � � T CABINET LEGS ( BELOW ) IS OPEN TO FLOOR A - LID I N CABINET LEGS (BELOW) . I . � 1 f • 1 1 CABINET BACKS REMOVABLE ADJACENT CABINET f W1 • � II, V / � l REMOVABLE CK IS = DIRECT DRAIN FROM SINK BASIN (ABOVE) TO WASTELINE IN BACKWALL I � 1 -- -- II i , ..._.......... ..............._: _. FRAME TO ADJACENT CABINET END PANELS L ,._ -, 4' �� `� \ CABINET BACKS ARE REMOVABLE ,' ` ] _ / \ / t \ I \ ADJACENT CABINET (REFERENCE f ADJACENT CABINET (REFERENCE ONLY) COUNTERTOP EDGE / L_ -- �� 1 -3 CABINET LEGS (BELOW) LAYOUT ADJACENT CABINET (REFERENCE ONLY) COUNTERTOP EDGE / EDGE OF DOOR � ' F RAME TO �- ADJACENT CABINET ONLY) COUNTERTOP EDGE � - `ll� L---/ ” ' " 2' 0 2-0 ONEY)RENCE 4- WORKSTATION COUNTERTOP EDGE (ABOVE) PREP AREA CABINET LAYOUT (ABOVE) BREWER CABINET LAYOUT (ABOVE) TRASH CABINET LAYOUT (ABOVE) /( HANDSINK CABINET 4 „ 1, -0» PLAN Y4." = 1' -0„ PLAN 3/4» 1' -0" PLAN C x ,, = 1 $— 0 ,, PLAN STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 701 Dexter Avenue Barth 4301 5e6111e, WA 9B109 -4342 1: 206.285.4300 4: 286.285.4971 46 . 6 Iympica sso of ores. rom OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION STORE #: 14777 PROJECT #: 12197 -001 • CONCEPT: SM FT PRNT PALETTE: dIMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE CASEWORK DETAILS s z > Ui El-- co Ca 0 Li- SCALE: 1 / 4=1 ' -0" '-`' I 1 (DO NOT SCALE DRAUVINGS) SHEET NUMBER A7.2 P"'" SOUTHCENTER I 1047 SOUTHCENTER MALL TUKWILA, WA 98188 STARBUCKS COFFEE COUNTY: KING COUNTY 20 19 18 16 V145 V141 V141 / ALIGN FRONT WITH ADJACENT APPLY FRP TO ALL SIDES OF CASEWORK CHASE. SEAL GAPS BETWEENMATERIAL USING CLEAR SILICONE (DOW CORNING 733) PER PRODUCT INSTRUCTIONS ---r j , 2x2 UPPER STORAGE CAB WI CHASE / 2x2 UPPER STORAGE CAB / 2x2 UPPER STORAGE CAB BACKBAR TILE CUBBIE FRONTS �_- _ --I — —_1 �- - -� I- - _ -- r — ---- UPPER CUBBIE WITH CHASE �•� BEYOND APPLY FRP WALL SUPPLIED BY CASEWORK VENDOR AND INSTALLED BY GC. 1Tr 7 I— � t J -1 r I I I _I COVERING BEHIND CUBBIE ON ALL EXPOSED SURFACES LINE ALL CHASE INTERIOR WALLS WITH FRP I I I I SS COUNTERTOP (mini ■ ■ ■ ■ •111 ■ ■ ■I ■I ■ ■ ■� • ■ ■ ■ ■ ■ ■ ■ ■� ■ ■ ■ ■ •••••••• ■� ■■ ■ ■ ■ ■ ■ ■ ■ 1 1 __ / EQ I ^{ I F ■■■■■■■ ■■ ■ ■ ■ ■ U■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■M ■■�■. ■ ■ ■ ■■■ III • ■■ I I �IiIIIIIIIIIIIuIIIIII 11111 IIII C937 P -LAM PANEL AND ■ ■ ■ ■ ■� ■ ■ ■ ■ ��� ■ ■� ■ ■ ■■ ■ ■■ ■ ■ ■� ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ I ME= MIME lip 1H1 ,111 ALIGN TOP OF FIELD CUT PANEL PANEL WITH ADJACENT FOR RECEPTACLE BACK SPLASH LOCATION I ' X11. i I 11 ■111 I1",,,,,,Ili• / 11IIIII11U 11Ii1IH� 11 SS RAIL. ALIGN PANEL W/ CORIAN BACKSPLASH 11111 11110111 ■■ ■■■■ ■ ■ ■ ■■ ■ ■W.:�r ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■■�•���MIK_�� 1 a,� ■ ■_ ■ ■ ■ ■ ■_ IIIHI■ ■ - i J _ I I e e ` L WARMING CART ■■ ■ ■■ - " / ® ® - 00 ® i� WARMII "FLEX 7 I / i" \ '\ CARS " < REFRIGERATOR �- _ / ` / `'\ N. - � ' ,, ,` �\ l- r- - C ' - I 1 i i k' \ b WARMING CART I ,,, 3 II II I I 11 1 1 i CASTERS 0 L '— / —' C932 & C934 WARMING STATION / AND SS TOP 2 6' 11-0" 11-0' ALL EXPOSED FASTENERS TO BE HEX HEAD, S.S. A'1: ' _ ' r FL 1 ��� - ^ ' �, -; ... . W :. -- -�� •” / / V104 V102 TRASH STORAGE CABINET „ CABINET , 4' -5 1/4 / FINISHED 0937 PANEL SECURE PANEL TO GWB WITH MOLT BOLTS; 1 PER GC TO SEAL GAPS BETWEEN MATERIALS AS REQUIRED BY LOCAL CODE W/ CLEAR SILICONE (DOW CORNING ( 733) PER PRODUCT INSTRUCTIONS ,>✓ / FUTURE WARMING MODULE V336 CORIAN COUNTERTOP CORNER USE HEX HEAD SCREWS; PAINT BLACK WHERE REQUIRED, GC TO REMOVE EXPOSED BLOCKING PRIOR TO INSTALLATION OF PANEL TO WALL t._-. FUTURE WARMING MODULE FUTURE WARMING MODULE 0 %" = 1' -0" ELEVATION % = 1' -O" ELEVATION OPPOSITE HAND 6 6 3 / 4 ' = 1 ' - 0" SECTION /SIDE VIEW OPPOSITE HAND 0 2' -6" 4' -5 1/4 " 0 0 0 _0, olb RECEIVED Ti F O CITY iV\ MLA CITY PERMIT CENTER 2 , C937 FINISHED PANEL C937 S.S. RAILS / V335 CORIAN TOP I I / RECEPTACLES FOR OVEN I ALIGN BACK OF OVEN WITH BACK y T ` C1II"'''yy Cpi111„IT �� . i „I� c C' OF SS TOP I 1' -4" J, 6 ",, I 0 3' -0" I 6 " Jr' L C' �' ,, REFRIGERATOR BELOW L -1 SILICONE SEALANT - APPLIED WHERE OVEN MEETS SS TOP ALL SIDES L. C' J L 1 ' - O" / WARMING STATION 0932 SS TOP DOUBLE V104 TRASH CABINET V102 STORAGE CABINET OVEN LH Y4„ = 1 ' -0" PLAN STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 4p 701 Beater Avecoe North #301 Seattle, 79A 98109•4342 I: 306.285.4300 f: 206.285.4371 ^: uww.elympi,ossoclates.tom OLYMPIC ASSOCIATES COMPANY REGISTERED . l- CIIITECT REV DATE PD DESCRIPTION 1- I- z 0 U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE CASEWORK DETAILS SCALE: 1 / 4=V-0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A7.3 FURNISHING, FIXTURE, & EQUIPMENT PLAN 0 1 2 3 4 8 12 I I I I I I I I I I F = = =1 u II SALES DISCONNECT BY LL ELEC PANELS 2 BY LL 1 BY SBUX PART NOTES: 0 0 0 I 0 0 0 0 0 10 11 12 13 14 15 20 THE SPACE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. EDIBLE PRODUCTS TO BE PHYSICALLY SEPARATED FROM STORAGE OF NON— EDIBLE OR TOXIC PRODUCTS. NO VEGETABLE OR FOOD PREPARATION ON THE PREMISES. NO ALCOHOLIC BEVERAGES TO BE SOLD OR CONSUMED ON THE PREMISES. THE MAXIMUM NUMBER OF EMPLOYEES PER SHIFT SHALL NOT EXCEED 4. ALL EQUIPMENT AND INSTALLATION WILL MEET NSF STANDARDS OR EQUIVALENT. NON — MOVABLE EQUIPMENT ON THE FLOOR SHALL BE MOUNTED ON 6" LEGS, CASTERS OR MANUFACTURER SUPPLIED SKIDS. NON— MOVABLE EQUIPMENT ON THE COUNTER SHALL BE MOUNTED ON 4" LEGS. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS. EACH HANDWASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. SECURE LOCKERS TO WALL. PLACE FIRE EXTINGUISHER IN WORKROOM PER FIRE INSPECTOR. GC TO SCHEDULE WITH LOCAL REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START —UP AND TESTING. FOR APPROVED CONTRACTOR, CONTACT STRUCTURAL CONCEPTS, attn: MELISSA GLASSNER (800) 433 -9489 ex 257. ALLOW MINIMUM 3 WEEK LEAD TIME PRIOR TO STORE TURNOVER. NUMBER NOT USED AT MANAGERS DESK M04 M04 M04 A022 A002 A700 9� A009 A014 7� A450F702 6 F710 A100 A037 16 MUSIC SPEAKER SEE SHEET A3.1 17 GC TO COORDINATE W/ CM LOCATION & INSTALLATION OF LADDER, BULLETIN BOARD & KEY BOX. 18 NUMBER NOT USED 0 SEE SHEET A3.0 FOR SCHEDULE INFO RECEIVED CITY OF T1.1K'A /I A FEB 0 8 2008 PERMIT CENTER STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 RI V N BARTHOLME STATE OF WASHINGTON OLYMPIC ASSOCIATES COMPANY i-rET 701 Beater AreIae North :381 Seattle, WA 98189.4342 I. 286.285.4388 1: 206.285.4371 v: www.olrnploossoolotes.rom REV DATE PD DESCRIPTION STORE #: 14777 PROJECT it 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE FURNITURE, FIXTURE & EQUIPMENT PLAN SCALE: 1 / 4 " =1'-0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A8.0 A001 1 PHONE - 1 LINE SYSTEM SCITEC SCITEC 205T 208,23 0/10 13.1 3/8" CWF 3/8" I W/ HOLD BUTTON 178081 3PL A002 1 TELEPHONE - 2 LINE GRAYBAR ELECTRIC CO ATT 982 N/A 4Q 3/8" CWF SURFACE MOUNTED 193019 3PL A009 1 CD PLAYER COMBO 0400 PLAY NETWORK C400 PACKAGE 120 60 WATTS S C400 PLAYER /PWR STRIP 512896 3PL A014 1 INTERACTIVE SECURITY -- A /EB DIEBOLD A /EB STORE EQUIPMENT 120 14.5 / 2.45 AM W/ FRONT PULL -OUT REFRIGERATION UNIT INCLUDES INSTALLATION 182297 VD A022 1 EQUIPMENT RACK - 6' CHATSWORTH 1 5321 -524 10 3 PLACE ADJACENT TO MANAGERS DESK 176662 3PL A037 1 AMPLIFIER 60W MUSIC SYSTEM PLAY NETWORK PA601 120 60 WATTS CWF W/ RACK FOR WARMING PROGRAM AMPLIFIER 512789 3PL A100 1 MANAGERS EQUIPMENT (RACK) IBM SBUX6792 115 9.8 USED WITH EQUIPMENT RACK 249166 VD A350 2 POS REGISTER - COMPACT TURBOCHEF SBUX4849 115 3.8 190034 VD A450 1 EXTRA CASH TILL - COMPACT SBUX4870 VD A700 1 WAN HARDWARE SBUX1700 120 1 VD E314 1 ICE MACHINE (AIR - 1000 #) ICE O MATIC C106HAP 208,23 0/10 13.1 3/8" CWF 3/8" I WITH 500# BIN 112639 3PL E318 1 ICE BIN - 500 LB ICE O MATIC B55PSA N/A 4Q 3/8" CWF SURFACE MOUNTED 109459 3PL E335 4 REFRIGERATOR UC 1 DR REVERSIBL DELFIELD 406STAR2 115 7 S FOR USE WITH DIGITAL BREWING SYSTEM 188939 3PL E338 1 FOOD CASE A -STORE W/ INSERT STRUCTURAL CONCEPTS SELF-CON TAI NED - HORIZ. 208V / 115V 14.5 / 2.45 AM W/ FRONT PULL -OUT REFRIGERATION UNIT 181804 3PL E422 1 REFRIGERATOR REACH -IN 2 DOOR TRUE TG2R 2S 115 10 3 247028 3PL E424 1 REFRIGERATOR UC 1 DR REVERSIBL DELFIELD 406STAR2 115 7 11.3 CWF W/ RACK FOR WARMING PROGRAM 357055 VD A602 4 POS BANK AMERICAN SECURITIES W/225X PIN 208/1 31.7 3/8 CWF HW 3/4" 155278 3PL A606 2 INDOOR /OUTDOOR SPEAKER SOUND TUBE SM4001 120/208 4Q 3/8" CWF SURFACE MOUNTED 454505 3PL E162 2 8D C H ESP VERISMO THERMOPLAN VERISMO 801 208/1 31.7 3/8 CWF HW 3/4" 189318 3PL E174 1 BREWER DIGITAL DUAL 208V BUNN -O-- -MATIC 33500.0015 120/208 4Q 3/8" CWF NEMA 14- 50R /P; 40AMPS © 208V 185966 3PL E451 1 SANITIZER, HOBART HOBART LXIH 120/208 -240 120/20 8 -240 38 3/4" HW 3/4" ID NEMA 14.50 R/P 181987 3PL E004 1 GRINDER -- COFFEE DITTING KR-1203 110 11.8 AT BACKBAR W/ BAG 145162 3PL E201 1 WATER FILTER - TASTE AND ODOR OSMONICS INCORPORATED TO -320 120 13 1/2" 187517 3PL E532 2 BLENDER KIT - SHROUD KTEC ICB3 NEW SHROUD 120 13 413562 3PL E533 1 SCALE W/ TOWER READOUT TOLEDO #8217 120 1 125726 3PL E548 1 STAND W/ TRAY - 2 SHUTTLE BUNN -O -MATIC 27875.0006 120 1.5 FOR USE WITH DIGITAL BREWING SYSTEM 185975 3PL E557 1 SAFE-INTERACTIVE SECURITY RH AMSEC BSD262020/8 140 -4 110 1 RH DOOR SWING 249168 VD E564 1 DISPENSER, FRAPP MANUAL AC DISPENSING AC 220 FIR W/ TRAY 120 3 187555 3PL E574 1 INSTA HOT TAP IN SINK ERATOR C- 1300STAR 120 11.3 CWF 277613 3PL E597 1 SAFE- BASE AMSEC SAFE BASE 249166 VD E599 1 OVEN WARMING TURBOCHEF NGC MICROWAVE CON VT 02N 30 190034 VD AUXILIARY SYSTEMS SCHEDULE: ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU # SHIP AUXILIARY SYSTEMS ACCESSORIES EQUIPMENT SCHEDULE: ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS GRINDING BREWING WATER SYSTEMS REFRIGERATION /ICE DISHWASHERS MISC SUPPLY WASTE REMARKS SKU # SHIP ACCESSORIES LE807 4 SOFT HEAT SERVER GRY BUNN -0 -MATIC 27850.0021 FOR USE WITH DIGITAL BREWING SYSTEM NOTES: 185974 3PL 0 WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE. STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 701 Dexter Aveoee North #301 Seattle, VA 981094342 t: 206.285.4300 I: 206.285.4371 rr: vwv.alympitossotiates.tcm OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE AUXILIARY & EQUIPMENT SCHEDULES tsj cc SCALE: 1 14 =1' -0 " (DO NOT SCALE DRAWINGS) SHEET NUMBER A8.1 M006 1 NY TIMES RACK COMPASS CP -314 CALL 877 - 787 -3250 TO ORDER 192379 GC M012 1 CONDIMENT TRASH DROP NORPRO 78730 MODIFIED 173271 3PL MO16 1 REFUSE BACKLINE TRASH MOLI INTERNATIONAL BTDL 1214 W/O LID 60 X 30 W/ INTERACTIVE SECURITY 190298 3PL MO23 1 LOCKERS - STD 10 COMPARTMENT STEINER CP -306A ATTACH TO WALL 192257 3PL M032 g SHELVES BACKROOM 18 "X36" 6 /BOX ISS WST966C 193264 3PL M033 8 POSTS 7' BACKROOM 4 /BOX ISS PZ86 CHROME 4 PER BOX 185915 3PL. M046 1 KEYBOARD DRAWER OFFICEMAX CONTRACT INC. 194761 3PL M047 1 BULLETIN BOARD BOISE CASCADE 24 X 36 801112 3PL MO49 1 FILE CABINET WORKPLACE LOGIC B9- 101121 101121 3PL M054 1 SOAP DISPENSER LAVATORY MN TD LOCKNET LLC AS10332 FOR RESTROOM SINKS 181934 3PL M055 1 1/2 SIZE TOWEL DISPENSER FORT HOWARD "C" FOLD TOP FEED 566-40 122312 3PL M056 2 FULL PAPER TOWEL DISPENSER FORT HOWARD #566-50 "C" FOLD 119873 3PL M067 1 MOP RACK LOCKNET LLC ASI8215 181939 3PL M072 2 24" WORKROOM WIRE SHELF KIT INTERNATIONAL STORAGE SYSTEMS GR2424Y (2) GS1424Y FOR USE OVER WORKROOM 3 -COMP SINK 166938 3PL M075 1 KAY CHEMICAL INSTALL KIT KAY CHEMICAL KIT 0043 CONTACT LINDA CAMPO (336) 931 -21 74 344451 GC M082 4 COAT HOOK SATIN NICKEL FINISH AMARI PAOO271 190782 3PL M1 55 1 1/2 SIZE TOWEL DISPENSER FORT HOWARD "C" FOLD TOP FEED 566 -40 SAME AS M055 122312 3PL M18Q 1 CONDIMENT TOP MSS METAL ASSY BFC ARCHITECTURAL 190381 3PL M221 1 CUP DISPENSER - SHORT HOT DIVERSIFIED METAL PRODUCTS ECL- NS -299P 194320 3PL M222 2 CUP DISPENSER - TALL HOT DIVERSIFIED METAL PRODUCTS ECL- NS -A34P 194318 3PL M223 4 CUP DISPENSER - GRNDE /VENTI HOT DIVERSIFIED METAL PRODUCTS ECL- NS -845P 194322 3PL M224 2 CUP DISPENSER - TALL COLD DIVERSIFIED METAL PRODUCTS ECL- NS -422P 194321 3PL M225 4 CUP DISP - • GRANDE /VENTI COLD DIVERSIFIED METAL PRODUCTS ECL -NS --845 194319 3PL FO85 2 TABLE, MODULAR SIDE 1 - DIMODA COMPASS CP -314 SCOOP CHAIR 192379 3PL F086 2 TABLE, MODULAR SIDE 2 - DIMODA COMPASS CP -315 192378 3PL F111 5 TABLE TOP 24" SQUARE DIMODA WEST COAST INDUSTRIES CP -305 60 X 30 W/ INTERACTIVE SECURITY 190437 3PL F112 1 TABLE TOP ADA 38" SQR DIMODA WEST COAST INDUSTRIES CP -306A 190438 3PL F137 12 CHAIR, CAFE - DIM ODA ALLERMUIR LTD AVJ432 SCOOP CHAIR 357112 3PL F139 8 BARSTOOL, 30" CAFE - DIMODA ALLEMUIR SCOOP HIGH STOOL 373101 3PL F163 4 CHAIR MODULAR 3 - DIMODA QUALITY AND CO CP -312C 60 X 30 W/ INTERACTIVE SECURITY 191709 3PL F164 3 OTTOMAN MODULAR - DIMODA QUALITY AND COMPANY CP -313 'VINYL' 190474 3PL F630 1 STAND HEAR MUSIC CD HAMILTON FIXTURE CP-108A/208 A /308A INLUDES PACKAGING & 16 SIGNS & CD BINS 192633 3PL F702 1 SHELF WALL MOUNT MANAGER W/S WATSON FURNITURE CP- 106B/206 B/3065 110882 3PL F710 1 DESK MANAGER 30 "X60 "X30 -1 /2 "H WATSON FURNITURE MODIF 126299 10## INSERT 60 X 30 W/ INTERACTIVE SECURITY 110881 3PL F842 2 POSTS 44" AFF - 10' SIT HERE WEST COAST INDUSTRIES CP-108A/208 A /308A POST & RAIL 190451 3PL F851 1 TABLE LEGS ADA (SET OF 4) WEST COAST INDUSTRIES CP- 106B/206 B/3065 190439 3PL F855 5 BASE TABLE MODIFIED BLK WRINKLINDUSTRIES WEST COAST MODIF 126299 10## INSERT W /BLACK WRINKLE FINISH 191610 3PL FURNITURE SCHEDULE: ITEM# TABLES CHAIRS MISC QTY ACCESSORIES DESCRIPTION MANUFACTURER MODEL # REMARKS SKU # SHIP MISCELLANEOUS SCHEDULE: ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU # SHIP M ISC LOCALLY SOURCED M918 2 U/C WIRE SHELF AT SINK SPOKANE STAINLESS A158 333413 3PL DObi-o7S0 RECEIVED CITY OF TlJK' flLA FEB 0 8 2008 PtHi.II T CENTER STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 t -TCT VA STA IE J N BARTHOLME F WASHINGTON 1 701 Dexter Avenue Garth 8301 36ottle, WA 98102.4342 t: 206.285.4300 1: 206.285.4371 u: www.olyapicossociotas.tom rr OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION z 0 U z F- a 0 U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE FURNITURE & MISCELLANEOUS SCHEDULES SCALE: 1 / 4 " =1' -0" (DO NOT SCALE DRAWINGS) SHEET NUMBER A8.2 HVAC ABBREVIATIONS GENERAL MECHANICAL NOTES: AIR HANDLING EQUIP. & MATERIALS: DUCTWORK & ACCESSORIES (CONTINUED): it B& SCOPE OF WORK O.S.A OUTSIDE AIR F & I FURNISH AND INSTALL U,N.O. UNLESS NOTED OTHERWISE U.O.N. UNLESS OTHERWISE NOTED CD CEIUNG DIFFUSER RG RETURN GRILLE EG EXHAUST GRILLE AHJ AUTHORITIES HAVING JURISDICTION LL LANDLORD „ "MECHANICAL NOTE: CONTRACTOR MEANS MECHANICAL (HVAC) CONTRACTOR" (SEE LANDLORDS SCOPE OF WORK TO DETERMINE IF WORK IS BY LANDLORD'S OR STARBUCKS HVAC CONTRACTOR.) WHEN REFERENCED ANYWHERE IN THE MECHANICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED " , "PROVIDE", AND "INSTALL" MEANS ALL ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE OPERATIONAL SYSTEM(S). SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL WORK. SITE EXAMINATION THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHE P ANAND PIPING WILL BE INSTALLED T ALLED ND OF WILL REPORT ANY CONDITION MECHANICAL WORK. ITION THAT STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, NFPA, OTHER APPLICABLE AGENCIES AND AHJ AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS /SPECIFICATIONS AND THE CODES AND ORDINANCES, THE MOST STRICT STANDDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS & REQUIREMENTS OF THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD WITH OUT ANY EXTRA COST. PERMITS AND FEES THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK. WARRANTY THE MECHANICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT OF REPAIRING DEFECTIVE MATERIALS AND RESTORE ANY OTHER E WORK ND WORKMANSHIP. DAMAGED IN THE COURSE OF REP AND AIR HANDLING AND VAV UNITS AIR HANDLING AND VAV UNITS SHALL BE AS SPECIFIED ON M2.0 AND SHALL BE FURNISHED AND INSTALLED PER THE SCOPE OF WORK ON THIS SHEET. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DEUVERY, PROVIDING COMPLETE INSTALLATION INCLUDING SUPPORTS, PIPES, VIBRATION ISOLATION AND NECESSARY ACCESSORIES, AS WELL AS PROVIDING WARRANTY. FILTERS PROVIDE THREE (3 " (3) SETS OF 2" MERV 6 PLEATED DISPOSABLE FILTERS. USE ONE SET UNTIL COMPLETION OF CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION AND DELIVER ONE SET OF FILTERS TO STARBUCKS LABELED TO DENOTE THEIR RESPECTIVE AIR HANDLING UNIT. ALTERS TO BE FARR, OR SIMILAR. DUCT SEALANT SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON— HARDENING, NONMIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEAUNG JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS AROUND SPIN —IN FITTINGS AND FASTENING SCREWS WITH MASTIC. S UPPORTS PROVIDE HOT— DIPPED GALVANIZED STEEL, FASTENERS, ANCHORS. RODS, STRAPS, TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. DAMPERS PROVIDE OPPOSED—BLADE, MULTI —LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN DUCTS MR AND OVIDE EXHAUST ARE DAMPERS AND /OR COMBINATION FIRE SMOKE DAMPERS WHERE NEEDED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. COORDINATE WITH GC AND ELECTRICAL FOR FIRE ALARM INTERFACE AND POWER. PROVIDE DOORS CONVENIENTLY LOCATED ACCESS DOS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE DAMPERS. WHERE REQUIRED BY CODE OR AHJ, F &I MOTORIZED DAMPERS FOR PRESSURE RELIEF & OSA (NOT NECESSARILY SHOWN). DAMPER AIR LEAKAGE MOTORIZED AND NON — MOTORIZED DAMPERS USED FOR OUTSIDE AIR INTAKES, EXHAUST &RETURN OUTLETS ( INCLUDING THOSE WITHIN HVAC EQUIPMENT) SHALL HAVE A K A MAXIMUM AIR LEA AGE RATE WHEN TESTED PER AMCA STD 500 OF: MOTORIZED— 10CFM /FT 2 OF DAMPER AREA AT 1 " F W.G.(4 CFM T 2 OR 20 GEM/R WITHIN HVAC EQUIP. IN THE STATE OF OREGON) NON — MOTORIZED— "2OCFM /FT OF DAMPER AREA AT 1 W.G. EXCEPT DAMPERS SMALLER THAT 24" IN EITHER DIM. SHALL HAVE 4OCFM /FT 2 OF DAMPER GRILLES, REGISTERS & DIFFUSERS GRILLES, REGISTERS AND DIFFUSERS SHALL BE MANUFACTURED BY TITUS AND SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. . DIFFUSERS SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND SCHEDULES. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPE OF WALLS USED IN THIS PROJECT. THERMAL INSULATION PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL, STATE ENERGY CODE, AND A.H.J. AND OUTSIDE AIR DUCTS, AND ON CONCEALED T P PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT INSULATE EXPOSED DUCTWORK WITHIN THE SPACE (UNLESS REQUIRED BY A.H.J.) AND AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED. THERMAL INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50. INSULATE DUCTWORK ON ROOF PER CODE. IF ANY OF THE ABOVE IS CONTRARY TO THE REQUIREMENTS OF THE A.H.J., INSTALL PER A.H.J. ACOUSTICAL DUCT LINER UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1" GLASS FIBER ACOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZED INDICATED ON PLANS 2" IN EACH DIMENSION TO ACCOMMODATE LINER. LINER SHALL BE FASTENED TO DUCT WITH MECHANICAL LINER FASTENERS IN ACCORDANCE WITH SMACNA. NOTE: CONTRACTOR SHALL COORDINATE WITH LANDLORD AND OBTAIN A COPY OF THE TENANT CRITERIA MANUAL/SPECIFICATIONS AND ALL OTHER CONSTRUCTION REQUIREMENT DOCUMENTS FOR THIS PROJECT. CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH LANDLORD REQUIREMENTS /SPECIFICATIONS AND ADHERE TO THEM. LANDLORD'S SCOPE OF WORK: 4 4i ! C �� THE FOLLOWING ABBREVIATED SCOPE OF WORK SHALL BE COMPLETED BY THE LANDLORD'S CONTRACTORS AS SPECIFIED IN THE "LANDLORD WORK LETTER — EXHIBIT B AND TENANT CRITERIA MANUAL ". NOT ALL WORK IS NECESSARILY CALLED FOR IN THIS DESCRIPTION OR IN THESE PLANS. REFERENCE THE "LANDLORD WORK LETTER" AND "TENANT CRITERIA MANUAL" FOR A COMPLETE DESCRIPTION OF WORK SCOPE. 1. FURNISH AND INSTALL (F &I) PRIMARY AIR DUCT FROM VAV SYSTEM STUBBED INTO STARBUCKS SPACE. VAV SYSTEM SHALL BE CAPABLE OF PROVIDING STABUCKS 1600CFM MAXIMUM OF PRIMARY AIR. STARBUCKS CONTRACTORS SCOPE OF WORK: STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 DUCTWORK HVAC SYMBOLS LEGEND F ) TYPICAL SUPPLY DUCT UP /DN SHEETMETAL DUCTWORK ALL DUCTWORK TO BE RIGID SHEETMETAL CONSTRUCTED FROM GALVANIZED SHEET IN ACCORDANCE WITH SMACNA. FIBERGLASS DUCTBOARD IS NOT ALLOWED. ALL EXPOSED DUCTWORK TO BE ROUND, SPIRAL, OR RECTANGULAR LOCK -SEAM TYPE, AS SHOWN ON HVAC PLAN. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (5X LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL REQUIRED DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES CONE GUR TION OR SIZES WILL BE PERM TT SYSTEM E . CEPT BY VARIATION RM SSION OE FROM OM THE ENGINEER. FLEXIBLE DUCTWORK DUCT WORK SHALL ONLY BE INSTALLED AS SHOWN IN PLAN. FLEXIBLE DUCTWORK SHALL BE PULLED TAUT AND APPROPRIATELY FASTENED TO RIGID BRANCH DUCT & DIFFUSER. BENDS SHALL BE MINIMIZED AND WHERE NEEDED BE A FULL RADIUS BEND. SUPPORT BANDS SHALL BE INSTALLED SO AS TO NOT CRIMP FLEX DUCT. FLEXIBLE DUCTWORK SHALL BE UL 181 LISTED AS A CLASS 1 AIR DUCT. STARBUCKS CONTRACTORS SHALL BE RESPONSIBLE FOR ALL WORK NOT COVERED ABOVE TO COMPLETE & MAKE FULLY OPERATIONAL ALL HVAC SYSTEMS. (COORDINATE WITH STARBUCKS GC). IN ADDITION, INCLUDE ALL COSTS TO HAVE LANDLORD'S APPROVED ROOFING CONTRACTOR COMPLETE ALL ROOF WORK. THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STAR9U CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF R (OR ANY PORTION MATERIALS THESE TERIAL (OOTION OF THEM) THESE T TERIAL (O PRIOR O CONSENT IS STRICTLY PROHIBITED. U L___ TYPICAL RETURN DUCT UP /DN r TURNING VANES CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. (425) 739 -6051 SUITE 200 (425) 739 -7362 KIRKLAND, WA 98033 AERI23 @AOL.COM EQUIPMENT DESIGNATION THERMOSTAT SENSOR SUPPLY AIR ARROW RETURN AIR ARROW DUCT HEATER LANDLORD REQUIREMENTS I EF -11 TQ Q THE FOLLOWING LANDLORD REQUIREMENTS /SPECIFICATIONS IS AN ABBREVIATED OVERVIEW. IT IS THE CONTRACTORS RESPONSIBILITY TO OBTAIN, BECOME COMPLETELY FAMILIAR, AND ADHERE TO ALL OF THE LANDLORD'S REQUIREMENTS. WHERE LANDLORD REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS, LANDLORD REQUIREMENTS SHALL GOVERN. 1. VAV UNITS AND AIR HANDLERS SHOWN HEREIN DO NOT REQUIRE DUCT SMOKE DETECTORS IF SIZED 2,000 CFM OR LESS PER LANDLORD'S BULLETIN 18. 2. PRIOR TO MAKING ANY DRILL AND /OR POSTION NG ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH --LOCATIONS AS INDICATED ON LANDLORD — APPROVED PLANS AND APPROVED BY LANDLORD'S CONSTRUCTION FIELD COORDINATOR. 3. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND PORTABLE FIRE EXTINGISHER (MINIMUM SIZE 2A:20BC), WHEREVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR THE LEAST ONE (1) HOUR AFTER COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED OF TUKWILA FIRE DEPARTMENT. 4. STARBUCK'S IS TO FURNISH AND INSTALL AN INDEPENDENT CONTROL SYSTEM TO CONTROL THEIR VAV AND AHU 5. LABEL ROOFTOP EQUIPMENT WITH TENANT NAME AND SUITE NUMBER. 6. ALL DUCTWORK IS TO BE SUPPORTED FROM BAR JOISTS OR BEAMS. DUCTS SHALL NOT BE SUPPORTED FROM Al CONDUIT, ETC. -IP- -4 REV DATE JC DESCRIPTION i TESTING, ADJUSTING, BALANCING: p co P-, MANUAL VOLUME DAMPER BACK DRAFT DAMPER BAROMETRIC DAMPER DUCT SMOKE DETECTOR MOTORIZED DAMPER MECHANICAL CONTRACTOR OR AN INDEPENDENT AIR BALANCE CONTRACTOR (HIRED BY MECHANICAL CONTRACTOR) SHALL ACCURATELY BALANCE THE AIR & HYDRONIC (WHERE APPLICABLE) SYSTEMS TO PROVIDE AIR & WATER QUANTITIES (WHERE APPLICABLE) INDICATED ON THE DRAWINGS AND IN THIS SPECIFICATION. WHERE QUANTITIES ARE NOT INDICATED BALANCE PER INDUSTRY STANDARD TO PROVIDE A PROPERLY WORKING SYSTEM. OPERATE AUTOMATIC CONTROLS SYSTEM AND VERIFY SET POINTS. A NEBB OR AABE CERTIFIED SUPERVISOR SHALL BE IN CHARGE OF WORK. SUBMIT TWO (2) COPIES OF THE BALANCE REPORT TO THE ENGINEER FOR APPROVAL. INCLUDE A COPY OF THE BALANCE REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL CONTRACT PAYMENT. 9 ii i © COMBINATION SMOKE AND FIRE DAMPER SPIN —IN TAKE —OFF AND VOLUME DAMPER ' Q > UNDERCUT DOOR 12" 8" INDICATES UNLINED 12 x 8 I O .D. SHEETMETAL (1ST FIGURE = SIDE SHOWN 2ND FIGURE = SIDE NOT SHOWN) INDICATED 14" x 10" O.D. SHEETMETAL W /1" SOUNDLINER (U.N.O.), 12" x 8" I.D. NET S YSTEM COMMISSIONING CONTROLS &OPERATION: 12 X 8 CONTRACTOR SHALL PERFORM AND PROVIDE THE FOLLOWING (SEE SPECIFICATION FOR FURTHER REQUIREMENTS): ( ) SYSTEM COMMISSIONING: POST CONSTRUCTION COMMISSIONING CONTROL WIRING THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING IN CONDUIT NECESSARY FOR THE COMPLETE AND PROPER OPERATING TEMPERATURE CONTROL SYSTEM INCLUDING ALL MODES OF OPERATION AND INTERLOCKS. THERMOSTAT - AIR HANDLING UNIT: THERMOSTATS SHALL BE HONEYWELL PROGRAMMABLE T -7351F WITH REMOTE ROOM SENSOR(S) 17770 FURNISHED AND INSTALLED PER SCHEDULE. ONE THERMOSTAT AND SENSOR IS PROVIDED FOR THE AIR HANDLING UNIT. MOUNT THERMOSTAT(S) AND ROOM SENSOR(S) IN LOCATION AS INDICATED ON DRAWINGS. MECHANICAL CONTRACTOR TO PROVIDE THERMOSTAT AND ROOM SENSOR IDENTIFICATION LABELS WITH 1/8 HIGH WHITE LETTERS ON KELLY GREEN OR BLACK PHENOUC BACKGROUND, E.G. AC -1 • WORKROOM" AND "AC -2 : CUSTOMER AREA ". REFER TO THERMOSTAT SETUP INSTRUCTIONS BELOW FOR ADDITIONAL REQUIREMENTS. THERMOSTAT SETUP INSTRUCTIONS PROVIDE THE FOLLOWING SETUP: 1. FOLLOW INSTRUCTIONS IN THE MANUAL WHICH COMES WITH THE THERMOSTAT. ADDITIONAL INFORMATION AVAILABLE FROM HONEYWELL INC., HOME AND BUILDING CONTROL DIVISION. 2. SET DIP SWITCHES AND JUMPERS AS FOLLOWS: A DEGREES F DISPLAY B 12 HOUR CLOCK C CONTINUOUS FAN OPERATION IN OCCUPIED MODE- D DISABLE KEYBOARD PROGRAMMING E CUT JUMPER IF UNIT IS A HEAT PUMP 3. SET CLOCK AND DAY. 4. SET TO DISPLAY CURRENT TEMPERATURE. 5. SET OCCUPIED START TIME AT 1 2 HOUR BEFORE OPENING. SET UNOCCUPIED START TIME AT 1/2 HOUR AFTER CLOSING. VERIFY HOURS WITH STORE MANAGER OR CONSTRUCTION MANAGER. 6. SETPOINTS SHALL BE AS FOLLOWS: OCCUPIED UNOCCUPIED HEATING 68 deg F 60 deg F COOLING 75 deg F 80 deg F 7. SET UN— OCCUPIED OVER —RIDE TO 3 HOURS. 8. SET OCCUPIED OVERRIDE FUNCTION TO PROVIDE THE FOLLOWING SETPOINT OVERRIDES: HEATING +2deg F COOLING —2deg F THERMOSTAT - VAV UNIT: SEE M2.0 SHEET wic) •/ t ~'^ , ? �'FQ� 12 X 8 1. ALL HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT 1. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH INSTALLATION SHALL BE PROVIDED TO THE BUILDING THESE PLANS AND SPECIFICATIONS. SEQUENCE OF OPERATION OWNER. RECORD DRAWINGS SHALL INCLUDE AS A SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN MINIMUM THE LOCATION AND PERFORMANCE DATA ON ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. A EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE OF DUCTS, INCLUDING SIZES, AND THE TERMINAL AIR PREPARED AND FILED WITH THE OWNER. QUANTITIES. 2. ALL HVAC SYSTEMS SHALL BE BALANCED IN ACCORDANCE WITH 2. OPERATING MANUALS AND MAINTENANCE MANUALS SHALL GENERALLY ACCEPTED ENGINEERING STANDARDS. AIR FLOW ALSO BE PROVIDED TO THE BUILDING OWNER. THE MANUALS RATES SHALL BE MEASURED AND ADJUSTED TO DELIVER FINAL SHALL BE IN ACCORDANCE WITH INDUSTRY ACCEPTED FLOW RATES WITHIN 10% OF DESIGN RATES INDICATED ON THE STANDARDS AND SHALL INCLUDE, AT A MINIMUM, THE PLANS. A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE FOLLOWING: OWNER. a. SUBMITTAL DATA STATING THE EQUIPMENT SIZE 3. AIR SYSTEMS SHALL BE BALANCED IN A MANNER TO FIRST: AND SELECTED OPTIONS FOR EACH PIECE OF MINIMIZE THROTTUNG LOSSES THEN, FOR FANS WITH SYSTEM EQUIPMENT REQUIRING MAINTENENCE. POWER OF GREATER THAN 1 HP, FAN SPEED SHALL BE ADJUSTED TO MEET DESIGN FLOW CONDITIONS. b. OPERATION AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, PRELIMINARY COMMISSIONING REPORT: EXCEPT EQUIPMENT NOT FURNISHED AS PART OF — • - - FLEXIBLE CONNECTION ' I? FLEXIBLE DUCT 2 "� NECK SIZE CFM CD -1 400 DESIGN CFM (WHERE APPLICABLE) SHOWN FOR RETURN ARE UNOCCUPIED MODE DIFFUSER TYPE, REF. SCHEDULE Q CEILING DIFFUSER FLOW ARROWS SHOWN INDICATE DIRECTION OF AIR FLOWS) r. CEILING RETURN /EXHAUST GRILLE THE PROJECT. REQUIRED ROUTINE MAINTENANCE 1. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND ACTIONS SHALL BE CLEARLY IDENTIFIED. RESULTS SHALL BE PREPARED. THE PRELIMINARY REPORT SHALL c. NAMES AND ADDRESSES OF AT LEAST ONE IDENTIFY: SERVICE AGENCY. a. DEFICIENCIES FOUND DURING TESTING REQUIRED BY THIS d. HVAC CONTROLS SYSTEM MAINTENANCE AND SECTION WHICH HAVE NOT BEEN CORRECTED AT THE TIME OF REPORT PREPARATION AND THE ANTICIPATED DATE OF CAUBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE CORRECTION. DESCRIPTIONS. DESIRED OR FIELD DETERMINED b. DEFERRED TESTS WHICH CANNOT BE PERFORMED AT THE SET POINTS SHALL BE PERMANENTLY RECORDED ON CONTROL DRAWINGS AT CONTROL DEVICES, TIME OF REPORT PREPARATION DUE TO CLIMATIC OR, FOR DIGITAL CONTROL SYSTEMS, IN CONDITIONS. PROGRAMMING COMMENTS. c. CLIMATIC CONDITIONS REQUIRED FOR PERFORMANCE OF e. A COMPLETE NARRATIVE OF HOW EACH SYSTEM IS THE DEFERRED TESTS, AND THE ANTICIPATED DATE OF EACH INTENDED TO OPERATE INCLUDING SUGGESTED SET POINTS. DEFERRED TEST. 3. CONTRACTOR SHALL TRAIN THE APPROPRIATE MAINTENANCE STAFF FINAL COMMISSIONING REPORT: STARBUCKS REPRESENTATIVE) FOR EACH EQUIPMENT TYPE M3.0 DETAIL MARK PROJECT #: 12197 -001 ISSUE DATE: 01/28/08 CHECKED: JOHN BEEBE DESIGNED: CHRIS RENSCH DRAWN: SHARON HARRIS BUILDING CODE NOTES: PERFORM ALL WORK PER ALL CODES. SHEET TITLE MECHANICAL SPECIFICATIONS SCALE: (DO NOT SCALE DRAWINGS) (AND /OR AND /OR SYSTEM. THE TRAINING SHALL INCLUDE AS A MINIMUM: 1. FINAL COMMISSIONING REPORT SHALL BE A REPORT OF TEST a. SYSTEM /EQUIPMENT OVERVIEW PROCEDURES AND RESULTS WHICH SHALL BE PREPARED AND FILED WITH THE OWNER. b. REVIEW OF THE AVAILABLE O &M MANUALS. c. REVIEW OF THE RECORD DRAWINGS d. HANDS —ON DEMONSTRATION OF ALL NORMAL MAINTENANCE � �t k �4 � is� w SHEET NUMBER MLO _ EXPiR E� �a OD Q CO 0 Lil HVAC SCHEDULE: HVAC SCHEDULE: 4‘ fl. � 1►� L� RD? =?fir �� (CONFIRM ALL QUANTITIES WITH PLAN VIEW AND STARBUCKS) ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SHIP ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU # SHIP SUPPLY AHU-1 1 3.0 TON AIR HANDLER LENNOX C B30M - 41--1G W /OUT ELEC. HT 460Vf 14� MCA =2 MOCP= 15 INDIRECT 4 ITY 3.0 TON CAPAC MAX ESP 1200CFM C�+O.S WEIGHT =177 LBS CD -1 CD -2 CD - 3 4 SQ. —WAY SUPPLY — HARD LID T US I T ID C#6 — 12X12 18X18 4 —WAY — 12IN DUCT GC 2 SQ. 4 —WAY SUPPLY -••• LAY-IN TITUS TD C #3 — 14X14 24X24 4— WAY — 14IN DUCT GC STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 1 24" 24 SLOT DIFFUSER TITUS MP -39 3EA 1 "SLOTS 24" LENGTH 8 "0 DUCT CONN. GC Cu-, 1 3.0 TON A/C UNIT LENNOX T5A036 -52N41 G 460V/30 MCA =7.6 MOCP =15 3.0 TON COOLING CAPACITY W /OPTIONS AS NEEDED WEIGHT= 1 50LBS RETURN RG -1 RG - 2 2 SQ. RETURN — HARD LID TITUS 35ORL — 22X22 24 X 24 FACE HARD LID GC VAV -1 1 SERIES POWERED VAV FAN TERMINAL BOX ENVIROTEC 12 CFR-1 1221 W /ECM MOTOR& 6.0 KW ELEC HT MOTOR: 277V/1� HEATER: 480V/10 MOTOR: FLA =5.5 HEATER: FLA=21.7 1 6 CF M FAN ® 0.9" MAX ESP 1600CFM MAX /300CFM MIN PRIME AIR 3 /4HP ECM MOTOR W /OPTIONS AS NEEDED H254 1 SQ. RETURN — LAY —IN TITUS 350RL #3 22X22 24X24 — 22" DUCT GC THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO. TRADEMARKS AND DESIGNS ARE NE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION. MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. M I SC HSO1 1 THERMOSTAT WITH SENSOR HONEYWELL 17351 F W/ 17770 REMOTE SENSOR GC CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. (425) 739 -6051 SUITE no (425) 739 -7362 KIRKLAND, WA 98033 AERI23QAOL.COM HVAC ROOF P LAN HVAC PLAN KEY NOTES 0 COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL MECHANICAL EQUIPMENT. 0 NUMBER NOT USED. 0 NUMBER NOT USED. 0 WALL MOUNTED THERMOSTAT FOR ROOFTOP A/C UNIT AT 60" AFF. THERMOSTAT SHALL BE 7 -DAY PROGRAMMABLE WITH NIGHT SETBACK AND A MINIMUM 5 DEGREE DEADBAND. CONFIRM HEIGHT COMPLIES WITH BARRIER FREE, AND ALL OTHER LOCAL REQUIREMENTS. © REMOTE TEMPERATURE SENSOR AT 60" AFF ON WALL 0 MANUAL BALANCE DAMPER (TYPICAL). 0 NUMBER NOT USED. 0 SUSPEND VAV1 t LING W /VIBRA11CkI 'rn' ATnnr o. XIBLE DUCT CEI. MAINTAIN ACCESS T( UNITS PER CODE & MANUF. REQUIREMENTS. 1" DUCT LINER IN DUCTS AS SHOWN. INCREASE DIMENSIONS OF DUCT SIZE INDICATED TO ALLOW FOR LINER. 10 ENSURE UNIT �S MOUNTED A MIN• OF 6" OFF THE 11 MULTIPLE THERMOSTATS SHALL BE STACKED IN A CONFIGURATION WTH A MINIMUM 8" CLEARANCE BE LOW EACH -- 28 REV DATE JC DESCRIPTION CONNECT TO EXIST. PRIMARY AIR DUCT (CONFIRM) 22X22 12X12 12X12 22X22 RG -1 -- CD--1 pal CD -1 500 RG -1 -- 16 »0(EX) POWER I � � DISCONNECT S WITCH • ELECTRICAL PANELS --�1-- O O O I__ I u iII FEE VD #1310 t (I� ,,, U IIIY I' ���il ■ , T !� I \ 1 I I 1 B A C K B A R O E „ 12 14X14 12 F &I ENVIRO -TEC ANALOG CONTROL SYSTEM THAT IS COMPATIBLE WITH O -- - _ 7- T- S _ialt l CD -2 600 O ONL Q' 12" 0 s „0 SERIES FAN POWERED VAV UNIT. CONTROLS SHALL INCLUDE PROGRAMMABLE THERMOSTAT (TO SUIT STARBUCK OR COMPLETE & SYSTEM. Q YSTEMP�_�! MODULATE PRIMARY AIR VALVE AS NEEDED TO MEET THERMOSTAT'S COOLING SETPOINT. THERMOSTAT SHALL HAVE AT LEAST ONE STAGE OF HEATING AND SHALL TURN OFF /ON HEATING ELEMENT AS NEEDED TO MEET THERMOSTAT 5 HEATING SETPOINT. PRIMARY AIR VALVE SHALL STAY IN MIN. POSITION DURING HEATING MODE. VAV UNIT SHALL SHUT DOWN - L DURING UNOCCUPIED MODE & CLOSE PRIMARY AIR Q O O 0 0 _ _ f l _ r » �� �� ► � i 1Q ® CD -1 300 r �� � ►18X1 ��� �� CU -1 SURFtACE MOUNT REFRIG. 4" PIPE SLEEVE THRU ROOF FOR STUBB -- rill Q ON ROOF LINES (2EA) &POWER CONDUIT TO CONCRETE POWER AND REFRIG. LINES. SEAL PENETRATION PER LL ROOFING ABOVE CEIL NG THRU 2ND FLOOR, (SEE ROOF PLAN) L E S SEATING � N VAV �1 ,AI L . 0 w CURE. (CONFIRM) CONTRACTOR REQUIREMENTS. ,�0 I- 00 10 " - ® � � . . ..J�l Z a r of 1 COLUMNS AT SECOND FLOOR CD -1 300 VAV1 aO. w r 1 Q �--- 10 -.0.:---:- 11114 : ;� II��� 1 i 0 t) I 4 1 I I , I e . u I 711RIII 24" 3 -SLOT J �� ' nip •` /RG2�� 1 NV'ii'V „ -9MI I CD -3 100 PIPE SLEEVE DOWN THRU FLOOR TO STARBUCKS SPACE. OFFSET WITH 30 DEC. MAX ELBOWS. MAINTAIN CONTINUOUS RACEWAY FOR STARBUCKS POWER AND REFRIG. LINES TO BE PULLED THRU SLEEVE. � ' 0 ", LL \ o �� R l i f _ 1 1 Q TYP 0 • PROJECT: S 0 U 1 806 SC TUKWI COUNTY: KING C L. 0 I o II o i 11 2 "0 I�- — 20X14 NOTES: 1. SEE ARCH. PLANS FOR DIMENSIONED DIFFUSER LOCATIONS. 2. CEILING SPACE IS BEING PLENUMS A RETURN AIR tt R O O M MAINTAIN CLEARANCE T O UNIT FOR AIRFLOW AND ACCESS. (CONFIRM) n S P A W O R K 2230 F &I INSULATED REFRIG. LINES PER CODE & MANUF. REQUIREMENTS. 0 OQ �' � III AHU1 PROJECT #; 12197 -901 ISSUE DATE: 01/28/08 CHECKED: JOHN BEEBE DESIGNED: CHRIS RENSCH DRAWN: DAN PURAVET m _ c , \ B - LOW 08,.......075 ,______} 14X14 ` - r L CD -2 600 A R ,^ :. HVAC PLAN ` . p. 1 2 3 4 8 12`"' SKYLIGHT ON ROOF SHEET TITLE HVAC PLAN & SCHEDULE SCALE: (DO NOT SCALE DRAWINGS) : r µ r F r BB i _: e -_ =r' ". i 2 �w {r - . 610 ,1 . SCREENED HVAC UNIT AREA ON ROOF PARKING LEVEL. . SEE SCOPE OF WORK KOtilSHEET M1.0 SHEET NUMBER M2.0 .,.„_ EXPIRES jiff / 5 Tr r ca CD CV a co LiJ LL PERMIT CENTER DUCT SIZE HANGER SIZE MAX. SPACING UP THRU 2 SQ.FT. 1" x 1/16" 8' -0" 2 THRU 4 SQ.FT. 1" x 1/8" 8' -0" 4 THRU 10 SQ.FT. 1" x 1/8" 6' -0" OVER 10 SQ.FT. 1" x 1 /8" 4'--O" COORDINATE CONNECTION /METHOD OF CONNECTION TO STRUCTURE IN HELD AND WITH STRUCT. PLANS (TYP.) HANGER STRAP SELF TAPPING SCREWS FOR DUCTS OVER 48" WIDE, TURN UNDER BOT OF DUCT & FASTEN FLEX DUCT. PULL INSIDE LINER TAUT. OPPOSED BLADE DAMPER (ONLY LOCATE IN THIS LOCATION IF DAMPER CAN NOT BE LOCATED NEAR BRANCH TAKEOFF). TYP SUSP LAY -IN CEILING. 3 � RIGID ELBOW J NOTES: 1. PROVIDE SUPPORT FOR DIFFUSER & CAP PER CODE. 2. DETAIL CAN BE USED FOR SUPPLY OR RETURN. 3. F &I EARTHQUAKE SUPPORT PER A.H.J. INSTALL CABLE SEISMIC RESTRAINSTS BOTH LONGITUDINALLY AND TRANVERSELY PER SMACNA REQUIREMENTS. � DUCT HANGING DETAIL I C I J N.T.S. SUPPLY OR RETURN RIGID DUCT. LAY -IN CLG DIFFUSER UNISTRUT HANGER THREADED ROD DUCT FLEX DUCT CLAMP. ROUND INSUL STUB DUCT SAME SIZE AS FLEX DUCT. SQUARE TO ROUND NO LABOR COLLAR. CLG DIFFUSER. FASTEN TO CAP WI SHT MIL SCREWS, MIN ONE PER SIDE. SEAL JOINT AIR TIGHT. ALL THREAD(TYP.) -�' LATERAL SUPPORT PER STRUCT. REQUIREMENTS (TYP.) RETURN -N3 AIR PLENUM SUPPORT FROM FACTORY PROVIDED SUSPENSION MOUNTS (CONFIRM) DRIP PAN UNDER ENTIRE UNIT PER CODE IF UNIT IS NOT PROVIDED W /EMERG. CONDENSATE SHUT -OFF OR AUX. CONN. (INDIRECT DRAIN(S) FOR CONDENSATE NOT SHOWN BUT SHALL BE F &I). N.T.S. FULL SIZE DUCT CONNECTION TO GRILLE N.T.S. TYPICAL SUSPENDED- LAY-IN CEILING SOUND LINER STRUCTURE VIBRATION - ISOLATORS (TYP.) VOLUME DAMPER DO O7' SEE SCOPE OF WORK ON SHEET M1.0 CONFIRM CONNECTION TYPE TO STRUCTURE W /STRUCTUAL ENGR. (TYP.) AIR HANDLER UNIT -SEE PLANS FOR LOCATION 4. SUPPLY > > FLEXIBLE DUCT CONN. (TYP.) F &I UNISTRUT W /ALL THREAD HANGERS IF FACTORY DOES NOT PROVIDE UNIT SUSPENSION MOUNTS. ENSURE HANGERS DO NOT OBSTRUCT ACCESS TO UNIT. SUSPENDED AHU DETAIL (SIMILIAR FOR VAV UNITS) 22" X 16" RETURN GRILLE AS SCHEDULED LAY -IN RETURN GRILLE (PIRIrS 4 ETURN AIR PLENUM STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS. AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT 15 STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 REV DATE JC DESCRIPTION ISSUE DATE: CHECKED: DESIGNED: DRAWN: SHEET TITLE SHEET NUMBER (425) 739.6051 (425) 739 -7362 AERI23@AOL.COM co rn F- z 0 z z 0 U PROJECT #: 12197 -001 01/28/08 JOHN BEEBE CHRIS RENSCH DAN PURAVET HVAC DETAILS SCALE: (DO NOT SCALE DRAWINGS) M3.0 5 co LU - c C ° U GENERAL PLUMBING NOTES: NOTE: "CONTRACTOR" MEANS "PLUMBING CONTRACTOR" (SEE LANDLORD SCOPE OF WORK ON THIS SHEET TO DETERMINE IF WORK IS BY LANDLORD'S OR STARBUCKS PLUMBING CONTRACTOR) WHEN REFERENCED ANYWHERE IN THE PLUMBING CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE PLUMBING AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED ", "PROVIDE ", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE PLUMBING WORK. SITE EXAMINATION THE PLUMBING CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND SHALL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, IAPMO, OR ICBO, OR OTHER APPUCABLE AGENCY AS APPUCABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES AND AHJ. IN CASE OF CONFLICT BETWEEN THE DRAWINGS /SPECIFICATIONS AND NE CODES AND ORDINANCES, THE STRICTEST STANDARD SHALL APPLY (IN THE OPINION OF THE ENGINEER). THE PLUMBING CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AND ALL ITEMS IN THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS OR OTHERS. PERMITS AND FEES THE PLUMBING CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES INSPECTIONS, AND OTHER COSTS NECESSARY TO COMPLETE THE PLUMBING WORK. WARRANTY THE PLUMBING CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF CONSTRUCTION OR REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. F &I A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. DIMENSIONS ARE TO FINISH FACE U.O.N. REFER TO ARCH. SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. COLD WATER SUPPLY LINES INSIDE CASEWORK & BAR AREA TO BE COVERED WITH 1/2" THICK SELF SEALING, SECTIONAL CLOSED —CELL FOAM INSULATION. PIPING: SOIL, WASTE AND VENT PIPING SOIL, WASTE AND VENT PIPING 10" AND SMALLER SHALL BE SERVICE WEIGHT, HUBLESS, CAST IRON PIPE AND FITTINGS WITH NEOPRENE GASKET AND STAINLESS STEEL SHIELD AND CLAMP. PROVIDE HUB —TYPE PIPE AND FITTINGS BELOW GRADE WHERE REQUIRED BY LOCAL CODES OR AHJ. HORIZONTAL RUNS SHALL DRAIN AT A GRADE OF 1/4 INCH PER FOOT WHERE POSSIBLE BUT IN NO CASE LESS THAN 1/8" PER FOOT. APPLY TO BUILDING DEPARTMENT FOR VARIANCE IF 1/8" IS NEEDED. COORDINATE WITH AHJ FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR DRAINS. PROVIDE PIPED DRAIN TO SANITARY IF REQUIRED BY AHJ. RELOCATE ANY VENTS NECESSARY TO GIVE 10 FOOT CLEARANCE FROM HVAC INTAKE. COORDINATE WITH HVAC CONTRACTOR, DOMESTIC WATER PIPING DOMESTIC WATER PIPING 2" AND SMALLER SHALL BE COPPER TUBE WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH LEAD FREE SOLDER. PROVIDE TYPE "L" COPPER TUBE ABOVE GROUND AND TYPE "K" BELOW GROUND. CONDENSATE DRAINAGE PIPING NE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR AIR HANDLING UNITS AND STARBUCKS EQUIPMENT. CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M" COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER. HANGERS & SUPPORTS THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS NEEDED FOR EQUIPMENT AND MATERIAL. ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED BY PIPE HANGERS SPACED NOT MORE THAN 10 FEET O.C. FOR PIPES 1-1/4" AND LARGER, AND 8 FEET O.C. FOR PIPES SMALLER THAN 1-1/4" AND AT EACH JOINT FOR SOIL OR WASTE PIPE. ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE NEEDED TO PREVENT SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY FABRICATED WITH GALVANIZED COATINGS; NONMETALLIC COATED FOR HANGERS IN DIRECT CONTACT WITH COPPER TUBING. CONNECTIONS INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. SCREW JOINT STEEL PIPING UP TO AND INCLUDING 1 -1/2 ". WELD PIPING USE NON—LEAD, NON — ANTIMONY SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE. CLEANOUTS PROVIDE J.R. SMITH OR EQUIVALENT FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS AND WHERE NEEDED IN ALL SOIL, WASTE, AND DRAIN LINES. IN AREAS WITH CERAMIC TILE OR CARPETED FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP. IN AREAS WITH RESILIENT FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP WITH TILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. WHERE CLEANOUTS OCCUR IN WALLS OF FINISHED AREAS, THEY SHALL BE CONCEALED BEHIND CHROME PLATED ACCESS COVERS. INSTALLATION INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1" CLEANING SPACE AROUND ALL PIPING, INCLUDING ANY ADDED PIPING INSULATION. F &I PER ALL CODES & A.H.J. PIPING (CONTINUED); INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM —BOARD PARTITIONS, CONCRETE FLOOR, AND ROOF SLABS. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION WITH FIRESTOPPING SEALANT MATERIAL. UNDERGROUND WATER AND SEVER LINES SHALL BE LAID IN SEPARATE TRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE AND AHJ, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE NEEDED FALL. TESTING ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED, AFTER TESTING IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY AHJ. TEST WATER PURITY ACCORDING TO AHJ AND SUBMIT CERTIFIED TEST RESULTS TO AHJ FOR REVIEW AND APPROVAL INSULATION: WATER PIPING PROVIDE THERMAL INSULATION ON ALL HOT & COLD WATER, AND HORIZONTAL WASTE PIPING IN CEILING SPACES, AND ON ALL COLD WATER PIPING IN CASEWORK AND BAR AREAS. USE SELF — SEAUNG CLOSED CELL FOAM OR JACKETED FIBERGLASS INSULATION WITH MANUFACTURER APPROVED ADHESIVES, SEALERS, AND COATINGS. ALL MATERIALS USED SHALL HAVE A FLAME SPREAD INDEX NOT MORE THAN 25 A SMOKE DEVELOPED INDEX NOT MORE THAN 50. UNLESS OTHERWISE REQUIRED BY THE AHJ OR ENERGY CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS: PIPE SIZE INSULATION THICKNESS LESS THAN OR 1" EQUAL TO 1Y" 2" DIA. OR GREATER 1 -1/2" (INSULATION VALUE = k VALUE NOT EXCEEDING 0.27 BTU * INCH /h *ft * F SAFETY COVERS INSTALL SPECIFIED NO —SCALD SAFETY COVERS WITH INSULATED FOAM LINER AND TAMPER PROOF STRAP AS FURNISHED BY STARBUCKS AT ALL EXPOSED PIPING. ICE BIN DRAIN INSULATE ICE BIN COPPER DRAIN LINES WITH 1/2 " THICK, SELF- SEALING, SECTIONAL, CLOSED CELL FOAM. RAIN CONDUCTORS (IF RAIN CONDUCTORS ARE NEEDED) INSULATE RAIN WATER CONDUCTORS WHICH PASS THROUGH OCCUPIED AREAS (AS APPUCABLE) WITH 1/2 " THICK FIBERGLASS. HVAC PIPING (ON PROJECTS WHEN HVAC PIPING IS USED) INSULATE REFRIGERANT SUCTION PIPING AND COOLING COIL CONDENSATE PIPING WITH CODE & MANUFACTURER SIZED, SELF SEALING, CLOSED CELL FOAM. INSULATE HVAC HOT AND CHILLED WATER PIPING SYSTEMS AND LOW PRESSURE STEAM AND CONDENSATE PIPING WITH WITH CODE & MANUFACTURER SIZED, HEAVY DUTY, SELF SEALING, JACKETED FIBERGLASS. BUILDING CODE NOTES: LANDLORD REQUIREMENTS THE FOLLOWING LANDLORD REQUIREMENTS /SPECIFICATIONS IS AN ABBREVIATED OVERVIEW. IT IS THE CONTRACTORS RESPONSIBIUTY TO OBTAIN, BECOME COMPLETELY FAMILIAR, AND ADHERE TO ALL OF THE LANDLORD'S REQUIREMENTS. WHERE LANDLORD REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS, LANDLORD REQUIREMENTS SHALL GOVERN. 1. PRIOR TO MAKING ANY PIPE OR DUCT ROOF PENETRATION OR CORE DRILL AND /OR POSTTONING OF ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS AS INDICATED ON LANDLORD — APPROVED PLANS AND APPROVED BY LANDLORD'S CONSTRUCTION HELD COORDINATOR. 2. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGISHER (MINIMUM SIZE 2A:20BC), WHEREVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR THE LEAST ONE (1) HOUR AFTER COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. 3. ALL SANITARY WASTE AND VENT PIPING SHALL BE CAST IRON WITH "NO —HUB" COUPLING. 4. ALL PIPING SHALL BE SUPPORTED FROM BEAMS OR BAR JOISTS. PIPING SHALL NOT BE SUPPORTED FROM ANY OTHER PIPE, DUCT, CONDUIT, ETC. VALVES: GENERAL PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT—OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. PROVIDE STOP VALVES FOR ALL EQUIPMENT WHETHER SHOWN ON THE DRAWINGS OR NOT. VALVES WATER VALVE PRESSURE RATING SHALL BE 125 PSI OR GREATER. UNLESS NOTED OTHERWISE VALVES SHALL BE AS FOLLOWS: VALVE TYPE CHECK VALVE (UP TO 2") FULL PORT BALL VALVE (UP TO 3 ") GATE VALVE (UP TO 3 ") TEMPERATURE AND PRESSURE RELIEF VALVE WATER HAMMER ARRESTOR BACKFLOW PREVENTER (WHOLE — HOUSE) BACKFLOW PREVENTER (SINGLE DEVICE) VACUUM RELIEF VALVE PRESSURE REDUCING VALVE TRAP SEAL PRIMER MANUFACTURER NIBCO NIBCO NIBCO WILKINS WILKINS WILKINS WILKINS WILKINS WILKINS JAY R. SMITH SUPPLY IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN 65 PSI, THEN PROVIDE A PRESSURE REGULATOR TO MAIN SUPPLY TO MAINTAIN WATER PRESSURE (NOT NECESSARILY SHOWN ON DRAWINGS). PROVIDE BACKFLOW PREVENTION AND MAINTAIN SERVICE IF REQUIRED BY AHJ. PLUMBING FIXTURES: WATER HEATER PROVIDE A RHEEM /A.O. SMITH OR EQUIVALENT, GLASS — LINED, ENERGY EFFICIENT, GAS—FIRED WATER HEATER, WITH CAPACITY AS INDICATED IN THE PLANS. WHERE GAS IS NOT AVAILABLE, PROVIDE A RHEEM OR EQUIVALENT ENERGY EFFICIENT, GLASS LINED, ELECTRIC WATER HEATER WITH SIMILAR CAPACITY AND RECOVERY RATES. PROVIDE INSTALLATION COMPLETE WITH FITTINGS AS SHOWN IN THE DRAWINGS. THE WATER TEMPERATURE SHALL BE SET AT 120' F FOR HOT WATER AND 105' F FOR TEMPERED WATER UNLESS REQUIRED OTHERWISE BY A.H.J. WATER FILTRATION — SYSTEM "A" PLUMBING CONTRACTOR TO INSTALL WATER FILTRATION SYSTEM FURNISHED BY STARBUCKS, AS INDICATED ON THE PLANS. PROVIDE INSTALLATION COMPLETE WITH ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON THE DRAWINGS & AS NEEDED. NOTE: CONTRACTOR SHALL CONTACT WATER PROCESSOR (FILTER) SUPPLIER TEN DAYS MINIMUM PRIOR TO NEEDING THE FILTER SYSTEM OPERATIONAL (CONFIRM LEAD TIME WITH C.M.) THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES, FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND RIGID TUBING. REFER TO SCHEDULES ON DRAWINGS (PLUMBING & ARCH. SCHEDULES) FOR A DESCRIPTION OF LISTED ITEMS AND FURNISH ANY AND ALL PLUMBING FIXTURES LISTED AS "GC" UNDER THE "SHIP" COLUMN. ANY DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE SCHEDULE SHALL BE BROUGHT TO THE ATTENTION OF THE GC PRIOR TO BID. THE GC SHALL COORDINATE WITH STARBUCKS FOR CLARIFICATION. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO SUPPUES. SCOPE OF WORK NOTE: CONTRACTOR SHALL COORDINATE WITH LANDLORD AND OBTAIN A COPY OF THE TENANT CRITERIA MANUAL /SPECIFICATIONS AND ALL OTHER CONSTRUCTION REQUIREMENT DOCUMENTS FOR THIS PROJECT. CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WIN LANDLORD REQUIREMENTS /SPECIFICATIONS AND ADHERE TO THEM. LANDLORD'S SCOPE OF WORK: THE FOLLOWING ABBREVIATED SCOPE OF WORK SHALL BE COMPLETED BY THE LANDLORD'S CONTRACTORS AS SPECIFIED IN NE ;)VbLORD WORK LETTER — EXHIBIT B AND TENANT CRITERIA MANUAL". NOT ALL WORK IS NECESSARILY CALLED FOR IN THIS DESCRIPTION OR IN THESE PL` N& REFERENCE THE "LANDLORD WORK LETTER" AND "TENANT CRITERIA MANUAL" FOR A COMPLETE DESCRIPTION OF WORK SCOPE. THE LANDLORD SHALL 1. F &I 1" DOMESTIC WATER SERVICE CAPPED AND VALVED IN STARBUCKS SPACE WITH LINE SIZE AND LOCATION AS INDICATED IN THESE PLANS. 2. F &I A 4" (OR GREATER IF REQUIRED BY AHJ) SANITARY SEWER WASTE LINE TO STARBUCK'S SPACE AS SHOWN ON THESE PLANS. 3. F &I A 4" GREASE WASTE LINE TO STARBUCK'S SPACE AS SHOWN ON THESE PLANS. 4. F &I A CAPPED 3" VENT UNE STUBBED ABOVE CEILING IN STARBUCKS SPACE, AND AS SHOWN IN THESE PLANS. 5. F &I TENANT FIRE SPRINKLER SYSTEM MAIN STUBBED INTO SPACE (NOT SHOWN IN THESE PLANS). STARBUCKS CONTRACTORS SCOPE OF WORK: STARBUCKS CONTRACTORS SHALL BE RESPONSIBLE FOR ALL WORK NOT COVERED ABOVE TO COMPLETE AND MAKE FULLY OPERATIONAL ALL PLUMBING AND SPRINKLER SYSTEMS. COORDINATE WITH STARBUCKS GC. IN ADDITION, INCLUDE IN BID PRICE FOR LANDLORD'S APPROVED FIRE SPRINKLER CONTRACTOR TO DESIGN, FURNISH AND INSTALL SPRINKLER SYSTEM.' PLUMBING SYMBOLS LEGEND CD CD CW HW -- --�CWF CWF —CWN —CWS RO- G BV ---p<1 CV 0 S OR W V GW CH. V PRV RV BFP HB LL LANDLORD SANITARY OR WASTE PIPING BELOW SLAB (U.O.N.) SANITARY VENT PIPING GREASE WASTE PIPING BELOW SLAB (U.O.N.) CONDENSATE DRAIN COLD WATER PIPING HOT WATER PIPING COLD WATER ALTERED CWN COLD WATER NANO FILTERED CWS COLD WATER SOFTENED TW TEMPERED HOT WATER RO REVERSE OSMOSIS WATER G GAS PIPING BALL VALVE GATE VALVE CHECK VALVE PRESSURE REDUCING VALVE RELIEF VALVE BACKFLOW PREVENTER HOSE BIBB SHOCK ABSORBER STRAINER WCO WALL CLEANOUT FCO FLOOR CLEANOUT FS FLOOR SINK WM WATER METER CONNECT TO EXISTING STOP VALVE AT FIXTURE U.O.N. UNLESS OTHERWISE NOTED U.N.Q. UNLESS NOTED OTHERWISE F &I FURNISH & INSTALL AHJ AUTHORITIES HAVING JURISDICTION STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS. AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION. MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AER123 @AOL.COM REV DATE JC DESCRIPTION c o Co Q D J o - U 0 0 PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE PLUMBING U SPECIFICATION SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER P1.0 CD CO rrt L1J Li 0 P012 1 ICE BIN 95LBS — STAINLESS SPOKANE STAINLESS ZURN -- Z7440 WF 1/2" CW /TW 1" I 15 "X25 "X20" 194924 VD P021 1 SINK -- SS HAND car WORKROOM SPOKANE STAINLESS EH5 -14- -W 208V/10 5KW 1/2" IPS H/C 1 1/2" D WALL MTD W /FAUCET — ADA COMPLIANT 179715 3PL P026 1 SINK — WORKROOM 3 COMPART SPOKANE STAINLESS 3C16X20 -2 -18 1/2" CW /HW 2" D 16 X 20 X 16 120019 3PL P034 3 SINK FLOOR — 12" SQ FERGUSON ENTERPRISES ZURN FD2375 —NH3 3" D W /3" PLUMBING TAIL PIECE 180465 3PL P036 1 MOP SINK FERGUSON ENTERPRISES ZURN Z- 1996 -24 1 /2" CW 3" D GC INSTALL BACKFLOW PREVENTER IN SUPPLY 180461 3PL P080 1 SINK DROP —IN FOR MSSV2 CBS SPOKANE STAINLESS KN26 -5012 SP 1/2" CWF 1 1/2" D W/ DRAINBOARD & GRATE 508824 VD P390 1 10" DIPPERWELL DEEP DRAWN FERGUSON ENTERPRISES INC ZURN Z -826F1 1 /2" CW 1 1/2" INDIRECT 357151 3PL P392 1 45 LB ICE BIN FERGUSON ENTERPRISES ZURN Z - 82651 1/2" 1" INDIRECT 344430 3PL P393 1 WORKSINK 1 /2"H W 1 /2 "CW 1 1/2" INDIRECT 344429 3PL P395 1 HAND SINK STAINLESS STEEL 1/2"HW 1 /2 CW 1 1/2" DIRECT 344428 3PL P354 1 FAUCET HANDSINK ZURN FERGUSON ENTERPRISES ZURN -- Z7440 WF 1/2" CW /TW AT RESTROOM HAND SINK 190076 3PL P355 1 WORKSINK FAUCET PRE —RINSE COMPONENT HARDWARE GROUP KN53- 1000 —BR 208V/10 5KW 1/2" CW /HW INDIRECT AT WORKROOM COMPARTMENT SINKS 181032 3PL P356 1 FAUCET & BRACKET FOR MOP FERGUSON ENTERPRISES ZURN 2- 1996 —SF 1/2" CW /HW INCLS INTGRL VACUUM BRKER & STP CHK VLVS 277679 3PL P360 1 FAUCET 14" WORKROOM ADD —ON COMPONENT HARDWARE GROUP KN55 -7014 183203 3PL P367 1 FAUCET BACKBAR PITCHER RINSER FERGUSON ENTERPRISES ZURN Z -825F1 1 /2" CW GC INSTALL BACKFLOW PREVENTER IN SUPPLY 182121 3PL P376 1 FAUCET 12" GLASS FILLER COMPONENT HARDWARE KN26 -5012 SP 1/2" CWF 185897 3PL P377 1 FAUCET LABORATORY HOT & COLD FERGUSON ENTERPRISES INC ZURN Z -826F1 1/2" CW /HW 189613 3PL P380 1 FAUCET BACKBAR WORKSINK FERGUSON ENTERPRISES ZURN Z - 82651 1/2" 194916 194916 3PL P804 3 FLOOR SINK HALF WIRE GRATE FERGUSON ENTERPRISES ZURN 180466 3PL P806 1 ELECTRICAL WATER HEATER A.O. SMITH DEN52 208V/10 5KW 3 CW /HW INDIRECT 50 GAL CAP./ 2EA 5KW NON -- SIMULTANEOUS ELEMENTS GC 3/4" CWF &CW BELOW COUNTER 3 PLUMBING SUPPLY PLAN 12 PLUMBING GENERAL NOTES F &I A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. 0 PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. OC COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. 0 DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. O REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. Q COLD WATER SUPPLY UNES INSIDE CASEWORK & BAR AREA TO BE COVERED WITH 1/2" THICK SELF SEALING, SECTIONAL CLOSED -CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. OG CONTRACTOR SHALL CONTACT WATER FILTER SUPPLIER 10 DAYS (MINIMUM) BEFORE THE TIME THAT THE FILTER SYSTEM IS TO BE STARTED UP. aH STOP VALVES SHALL BE F &I AT ALL PLUMBING FIXTURES EVEN IF NOT SHOWN IN PLAN. lO RUN ALL PIPING CONCEALED. Y REMOTE READOUT AT 60" AFFI (CONFIRM) 200A 480V 30 FUSED DISCONNECT SWITCH BY LANDLORD (CONFIRM). RECESSED ELECTRICAL PANELS 1 WATER SUBMETER W /REMOTE READOUT (TYPE PER LL REQUIREMENTS). PLUMBING SCHEDULE (CONFIRM ALL QUANTITIES WITH PLAN VIEW AND STARBUCKS) I TEM # QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU # SHIP FIXTURES FAUCETS ACCESSORIES PLUMBING PLAN KEY NOTES Q 1" CW TO WATER HEATER & 1" HW FROM WATER HEATER. INSTALL 3/4" TEMPERTATURE MIXING VALVE ABOVE HOT WATER TANK. 0 WATER HEATER AS SPECIFIED AND IN COMPLIANCE WITH APPLICABLE CODES AND ORDINANCES. CONTRACTOR TO ENSURE DIMENSIONS OF THE HEATER ALLOW INSTALLATION ABOVE THE MOP SINK. REFER TO WATER HEATER DETAIL EXTEND WATER HEATER THRU CEILING IF NEEDED.. C3 1/2" HW & CW TO FAUCET AT MOP SINK: PROVIDE APPROVED BACKFLOW PREVENTION DEVICE ON SERVICE FAUCET AS NEEDED. CAULK AND SEAL BACK OF SINK TO WALL Q 3(4" CW TO WATER FILTER & 3/4" CWF FROM WATER FILTER. PLUMBING CONTRACTOR TO FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ACTIVATION PROCEDURES FOR ALTERS. INSTALL ASSEMBLY ON WALL. REFER TO WATER FILTER DETAIL 05 1/2" HW & CW TO FAUCET & SPRAY AT COMPARTMENT SINK AND AT WORK SINK. CAULK AND SEAL BACK OF SINK TO WALL. Q 3/4" HW TO SANITIZER. INSTALL SHUT -OFF WITH 3/4" MALE HOSE -END FITTING AT 18" A.F.F. UNDER COMPARTMENT SINK. SHUT -O TO INCLUDE PRE / SSURE REDUCING VALVE, PRESSURE AND ARRESTOR SET @ 20 IN WALL CONNECT SANITIZER HW SUPPLY WITH 72 " LONG BRAIDED STAINLESS STEEL HOSE. 1/2" CWF TO ICE MACHINE. REDUCE TO 3/8" AT MACHINE. 1/2" TW & CW TO HANDSINK. 1/2" CWF TO COFFEE BREWER. INSTALL SHUT -OFF IN CABINET @24" AFF REDUCE TO 3/8 " AT UNIT. a co 0 rb 10 1/2" CWF TO ESPRESSO MACHINE. CONNECT 3/8" BRAIDED STAINLESS STEEL HOSE FROM SHUT -OFF TO ESPRESSO MACHINE WATER INLET. 1/2" CW TO DIPPERWELL FAUCET. 3/8" CWF TO HOT TAP. REDUCE TO 1/4 " AT UNIT, 3/8" CWF TO WATER TOWER FAUCET LOCATED IN WATER STATION. KEY NOTE NOT USED. KEY NOTE NOT USED. 3/4" CW STUB -OUT THRU WALL W /BALL SHUT -OFF VALVE. 3/4" CWF STUB -OUT THRU WALL W /BALL SHUT-OFF VALVE. KEY NOTE NOT USED. VERIFY BACKFLOW PREVENTER REQUIREMENTS OF EQUIPMENT & MAIN WATER SERVICE TO STARBUCKS WITH INSPECTOR BEFORE BID. BACKFLOW PREVENTERS SHALL BE FURNISHED, INSTALLED, & INSPECTED PER CODE (NOT NECESSARILY SHOWN). 20 1/2" CW TO PITCHER RINSER SINK FAUCET. F &I BACKFLOW PREVENTERS PER AHJ REQUIREMENTS & PER CODE. 21 F &I PRESSURE REDUCING VALVE IF PRESSURE WITHIN STARBUCKS EXCEEDS 65PS1. KEY NOTE NOT USED. KEY NOTE NOT USED. SEE SHEET P3.0 FOR TAG AND LOCATION. TIE INTO LANDLORD PROVIDED 1" DOMESTIC WATER SERVICE. VERIFY LOCATION AND REQUIREMENTS ON SITE BEFORE BID. 26 RUN ALL PIPING CONCEALED (TYP). R E $ STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS. AS WELL AS STARBUCKS' NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION. MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL. COM REV DATE JC DESCRIPTION oo oo c7; rn F- z 0 U z a PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH DAN PURAVET SHEET TITLE PLUMBING SUPPLY PLAN & SCHEDULE SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER P2.0 5 co CO LLI cII o U 0 0 Q P080 0 0 LP n u � I M, ■ ■■■ 1 � 1 • -I- 3"GW 0 IBACKBAR I 2 "V -, - - - 2 " V - - -PEI 0 0 9 ®0 t erAtiowili 0 0 (ALL TYPICAL) CO • P395 0 0 3 "GW 2 "V. 4 "W (EX) CONNE WASTE LOCA11 P026 0 00 021 t (CONFIRM C 2-1/2"V -3"V- - 4\-, 2 "V 4 "W (EX) 0 T WORKROOM 4" GW (E I I I I I I I L _� 17 0 3X2 ABS HUB DRAIN LOCATE TO SIDE OF UC REFER SLAB ON GRADE - EXISTING GRADE BEAMS AND PILE CAPS BELOW SLAB (TYPICAL; NOT ALL SHOWN), DO NOT PENETRATE /CUT THESE EXISTING STRUCTURAL ELEMENTS. (CONFIRM REQUIREMENTS FOR CUTTING, BACKFILL AND PATCHING SLAB WITH LANDLORD'S ENGINEER). PIPING SHALL BE ROUTED BELOW OR AROUND THESE ITEMS AS NEEDED. 2 3 4 (P393 SEATING SALES 12 PLUMBING WASTE / VENT PLAN (39DFU) (6DFU) CONNECT TO EXIST. GREASE WASTE (CONFIRM LOCATIONS ETC) S(3 DFU) RECESSED ELECTRICAL PANELS AIR HANDLER ABOVE CEILING PLUMBING GENERAL NOTES: �A F &I A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. 0 FOR FULL SCHEDULES AND COMPLETE LISTING SEE SCHEDULES. CONFIRM ALL QUANTITIES WITH PLAN. PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. 0 COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT, DIMENSIONS ARE TO FACE UNLESS OTHERWISE NOTED. 0 ALL INDIRECT DRAIN LINES SHALL BE ROUTED WITHOUT DIPS OR SAGS TO TERMINATE WITH AN AIR GAP INTO AN APPROVED !INDIRECT WASTE RECEPTOR. 0 REFER TO DETAILS FOR FURTHER REQUIREMENTS. NOTE: 1, ALL BELOW GRADE PIPES SHALL BE SUPPORTED FROM SLAB WITH STAINLESS STEEL HANGERS PER CODE AND LANDLORD REQUIREMENTS. 2. SEE UNDERSLAB CONDUIT PLAN FOR ADDITIONAL UNDERSLAB ITEMS. 3. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM FIXTURE TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE WITH AN AIR GAP PER CODE UNLESS INDICATED OTHERWISE. DO os PLUMBING KEY NOTES 0 0 0 0 0 0 0 0 10 11 12 13 14 15 16 17 0 20 21 2z 0 0 25 26 z7 28 3/4" PRESSURE RELIEF MOP SINK. 1" INDIRECT DRAIN FROM PAN TO MOP SINK. FROM WATER HEATER TO WATER HEATER DRIP 3" GREASE WASTE /2"V FROM MOP SINK. 2" DIRECT DRAIN FROM COMPARTMENT SINK TO GREASE WASTE. COORD. W/ AHJ PRIOR TO BID & F &I INDIRECT IF NEEDED. 1 -1/2" INDIRECT DRAIN FROM DISHWASHER TO FLOOR SINK. (DO NOT CONNECT TO GREASE WASTE. (SEE DETAIL) (2) 3/4" INSULATED INDIRECT DRAINS FROM ICE MACHINE TO FLOOR SINK. DO NOT INTERCONNECT DRAINS. INSTALL FEMALE PIPE THREAD FROM ESPRESSO MACHINE DRAIN TRAY TO INDIRECT HUB DRAIN. 2" INDIRECT LINE FROM HUB DRAIN TO FLOOR SINK. 1" INDIRECT DRAIN FROM DIPPER WELL TO FLOOR SINK. 1 -1/2" INDIRECT INSULATED MAINLINE FROM ICE BIN DROP TO FLOOR SINK. 1 --1/2" INDIRECT DRAIN FROM WATER STATION DRAIN BOARD TO FLOOR SINK. 3" WASTE /2 "V FROM FLOOR SINK. 2" GREASE WASTE/1-1/2"V FROM SINK. NUMBER NOT USED. 3" GREASE WASTE /2"V FROM FLOOR SINK. TRAPPED PRIMARY & AUX. CONDENSATE INDIRECT DRAINS FROM AIR HANDLING UNIT TO FLOOR SINK. VERIFY SIZE & LOCATION OF DRAIN BASED UPON EQUIPMENT REQUIREMENTS AND PLACEMENT. F &I CLEANOUTS AS NEEDED. FLOOR CLEAN OUT, MATCH SIZE TO DRAIN LINE. CONFIRM THAT THESE LOCATIONS ARE CORRECT & NOT AS SHOWN ON SHELL DWGS. NUMBER NOT USED, 1" INDIRECT DRAIN FROM CBS IDRAINBOARD TO FLOOR SINK. 2 "GREASE WASTE /1 -1 /2 "V FROM PITCHER RINSER SINK. IF DIRECT NOT ALLOWED, PROVIDE 1 --1/2" INDIRECT DRAIN. VERIFY WITH AHJ BEFORE BID. F &I ANY NEEDED INDIRECT PIPING FROM BACKFLOW DEVICES TO FLOOR SINKS (TYP)(NOT SHOWN). F &I ALL NEEDED INDIRECT PIPING (NOT NECESSARILY SHOWN). NUMBER NOT USED. FIELD LOCATE EXISTING VTR & CONNECT TO IT PER CODE. 3/4" INDIRECT DRAIN FROM WATER FILTER EQUIPMENT TO MOP SINK OR FLOOR SINK. EVEN THOUGH INDIRECT PIPING IS SHOWN AT THIS LOCATION, IT IS NOT SHOWN ELSEWHERE. ALL P -TRAPS (WITH INTEGRAL UNION) & TAIL PIECE TO BE TYPE ABS UP TO AND INCLUDING THREADED COUPLING TO BASKET STRAINERS AT ALL SINKS. F &I WALL CLEANOUTS AT ALL SINKS AND AS NEEDED (NOT SHOWN- TYPICAL). SEE SCOPE OF WORK ON SHEET P1.0 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL.COM REV DATE JC DESCRIPTION 0 0 co Et w in W co F (7•Ei Z z W Q O Z I 0 / co 0 (.0 QD F- w � o PROJECT #: 12197 -001 ISSUE DATE: CHECKED; DESIGNED: DRAWN: 01128/08 JOHN BEEBE CHRIS RENSCH DAN PURAVET SHEET TITLE PLUMBING WASTE / VENT PLAN SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER P3.0 FLOOR SINK SET FLUSH W /TOP FIN, FLR. (CONTRACTOR TO CONFIRM WITH AHJ IF HOT ESPRESSO TOP VALVE. (TYP} 3/4" BY -PASS LINE /] �B /]/7 � 1 , FLOOR SINK IS TO BE ELEVATED ABOVE SLAB) MACHINE 3/8" COPPER UNE 1 2" COPPER LINES / 3/8" MALE COMPRESSION _ 1/4" COPPER LINE 3/8" COPPER LINE / WATER TOWER C EXPANSION TANK SIZED AND INSTALLED �� O ��� " PER MANUF, RECOMMENDATIONS AND CODE. CAULK JOINT CHROME ESCUTCHEON (T(P) VACUUM RELIEF VALVE I _ in D IELECTRIC T THIN SET CERAMIC TILE, TYP. R GE NERAL ON 0 DINATE WITH TYPE OF F AND FLOOR SYSTEM ETC. • -' 1 ° 3/8" COPPER LINE ` BALL VALVE _ COMBINATION TEMPERATURE & M 3/4 " COPPER DOMESTIC WATER IN. BALL SHUT -OFF VALVE (REPLACE VALVES SUPPLIED W FILTER W/ NEW BRASS ONES -TYP.) _+ -, " 3/4 CWF OUT FLUSH VALVE- F &I FLEXIBLE INDIRECT DRAIN ALL THE WAY TO RECEPTOR. N UNION (TYP.) I PRESSURE RELIEF VALVE. " 3/4 RELIEF DRAIN ESPRESSO MACHINE AT MAIN - I _ I I , • I I - -- ._ ._ ._ ._. . ,-- - - - - -- : .:. . : p :.: ._..: , _ _ _ ._. • • . • • . • o . • •e • • � e•. o , ; ` IIN 1 Q • ' . o . , e ; e ; ' o • o . H CONC. INFILL 0 TRENCH - FOR BELOW GRADE UTILITIES BARISTA * 3/8" MALE COMPRESSION BALL VALVE 1/2" COPPER LINES BALL VALVE @STUB UP � TO MOP SINK. STRAP TO WALL STRUCTURE WITH DOMESTIC ELECTRIC WATER HEATER - 2" WIDE 16 GAUGE STEEL BANDS. S STA R B U C K S COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 - 1575 DA 0 0 • 0 p ` ] O O O ..1.,__} Cp �.:. • -DRAIN VALVE I/ )( c Oo 0 00o GRAVEL BACKFILL O 000 0 �°, O�� ! 0 0 • qa •; 0,07 DRIP PAN WITH INDIRECT DRAIN " " FILTERED = A- SYSTEM - CWF C - SYSTEM - RO 3/4 FILTERED SUPPLY REFER TO SUPPLY PIPING DIAGRAM TO MOP SINK BELOW O ���0 0 ' �`� SUPPORT PLATFORM BY OTHERS. i o QS NO -HUB CONNECTION �- 1" INDIRECT DRAIN TO MOP SINK - —o�� - BA RISTA F ILTERED W ATER MANIFOLD SCHEMATIC 21" L� MOP SINK THESE PLANS AND SPECIFICATIONS, AS WELL AS NAME AND LOGO, TRADEMARKS AND DESIGN A DESIGNS ARE THE EXCLUSIVE PROPERTY OF MO DI F I ATI CORPORATION. ANY REPRODUCTION, IALS (O P D R ` TION OF THEM) ESE MA� A W� LAPROHI PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. 3" WASTE TO DRAIN FLOOR S _ DETAIL �-� FLOOR ,o �� FILTER SYSTEM • ELECTRIC WATER HEATER 0 N.T.S. NTS * IF ONLY ONE ESPRESSO IS SHOWN IN PLAN VIEW AT THE FRONT LINE, F &I PIPE TO FUTURE LOCATION & BALL VALVE. N.T.S. NTS AER ENGINEERS 11155 120TH AVE. N.E. (425) 739 -6051 SUITE 200 (425) 739 -7362 KIRKLAND, WA 98033 AER123 @AOLCOM TO NO ONNECT CODE/AHJ CONNECT TO EQUIPMENT ANY SEWER VENT) KADET -AF CLEANER KADET -AF CLEANER FLEX HOSE MALE HOSE END DISHWASHER 2" INDIRECT ABS DRAIN SINK /ICE BIN PIPE HANGER SUPPORT (OR PIPE CLAMP SUPPORT A CHEMICAL DISPENSER PROVID� CLEANOUTS IN TURNS ENDS OF PIPE. - INDIRECT DRAINS -TRAP IF REQUIRED I PER CODE OR AHJ. CONDENSATE DRAINS -TRAP REQUIRED MANUF./CODE INSTALL PER MANUF. CODE REQUIREMENTS PIPE MATERIAL SHALL BE PER THESE -MOUNT BRACKET ON -MOUNT TO BACK CENTER W/ BOTTOM OF WALL OF MOP NEEDED. CLEANER DISPENSER SINK FAUCET SINK SURROUND ABS THREADED COUPLING TO BASKET STRAINER r"' ABS INDIRECT DRAIN PIPE ( SEE PLAN FOR SIZES). F &I ADDITIONAL OFFSETS AS MAY BE NEEDED. PIPE CLAMP SUPPORT AT PLANS AND/OR PER CODE. USE DWV FITTINGS IF REQUIRED BY CODE /AHJ. SLOPE PIPE PER CODE. SEE PLAN(S) FOR SIZE. (W/ ATMOSPHERIC BREAK) AA A • 70 REV DATE JC DESCRIPTION "WASTING TEE" PROVIDED WITH CHEMICAL MIX SYSTEM W /QUICK 1.1 SEE ARCH DETAILS FOR FURTHER INFORMATION CLEANOUTS AT ALL CHANGES - -� Ali!: J �, IN DIRECTION (OR AS ALLOWED BY AHJ) maw ABS DWV FITTINGS (TYP.) • DRAIN TERMINATION (& BLOCKING-NOT SHOWN) _ DISCHARGE INTO OPEN AREA OF FLOOR SINK W /2" AIR GAP �.--.-- FLOOR FIELD SUPPORT WITH UNISTRUT FLARED END -- TERMINATE ABOVE FLOOR SINK PER CODE. DISCHARGE INTO OPEN AREA ) 7—DISCHARGE FLOOR SINK W/2" GAP (OR AS ALLOWED BY CODE) ISC. FITTING (CONFIRM) (WYE (WYE SHALL NOT BE USED EVEN IF SHOWN ON ARCH DETAILS) • ' ~!. FLOOR SINK 1. NOTES: &I ALL WORK PER CODE AND AHJ REQUIREMENTS __ FLOOR SINK(OR FUNNEL EVEN IF NOT SPECIFICALLY SHOWN. DRAIN) 2. ALL PIPES SHALL BE RIGIDLY SUPPORTED AND ALL SUPPORTS & PIPES SHALL BE MOUNTED OFF THE FLOOR FOR CLEANING PURPOSES. 3. ALL FLEXIBLE INDIRECT DRAIN LINES FOR APPLIANCES SHALL BE INSTALLED PER CODE /AHJ AND MANUF. REQUIREMENTS. SUPPORT LINES SO THERE ARE NO SAGS OR DIPS IN LINE. CONDENSATE/EQUIPMENT WATER HOSE „ NOTES: 1. F &I ALL WORK PER CODE AND AHJ REQUIREMENTS EVEN IF NOT SPECIFICALLY SHOWN. 2. ALL PIPES SHALL BE RIGIDLY SUPPORTED AND ALL SUPPORTS & PIPING SHALL BE MOUNTED OFF THE FLOOR FOR CLEANING PURPOSES. 3. ALL INDIRECT DRAIN DISCHARGES SHALL OCCUR OVER CLEAR AREA OF FLOOR SINK AND NOT OVER GRATE. 4 C LO ANA PIP P R CODE AND F &I TRAPPED INDIRECT DRAIN AND VENT IF REQUIRED BY SINK INDIRECT DRAIN DETAIL FRESH W /QUICK DISC. FITTING MOP SINK BASIN FLOOR FLOOR SINK I 1, II I 11 I u u j ,, Z7 ---3 CHEMICAL MIXER DETAIL r— $ DISHWASHER DRAIN I INDIRECT DRAIN DETAIL N.T.S. 5 NTS NTS 0 NTS DOB ...r - r , r . F Ni :Nl 98 • PROJECT #: 12197 -001 ISSUE DATE: 01/28/08 CHECKED: JOHN BEEBE DESIGNED: CHRIS RENSCH DRAWN: DAN PURAVET SHEET TITLE PLUMBING DETAILS SCALE: (DO NOT SCALE DRAWINGS) SEE SCOPE OF WORK ON SHEET P1.0 ( SHEET NUMBER P4.0 EXi .-- — 1 ( :C f.....4 CC G73 11 CLD 0LI- O W m i. � O - t. 5 a- GENERAL ELECTRICAL NOTES: NOTE: CONTRACTOR MEANS ELECTRICAL CONTRACTOR" (SEE LANDLORD SCOPE OF WORK ON THIS SHEET TO DETERMINE IF WORK IS BY LANDLORD'S OR STARBUCKS ELECTRICAL CONTRACTOR) WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS. "AHJ" MEANS AUTHORITIES HAVING JURISDICTION, "NEEDED" MEANS ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS PLUS ANY OTHER ITEMS TO MAKE A COMPLETE AND OPERABLE SYSTEM THAT ARE NOT CALLED OUT. ® THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK (SEE ELECTRICAL SPECIFICATIONS). ® THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. Q EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. ®D ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES AND PER REQUIREME / NTS OF THE A.H.J. IN CASE OF CONFLICT BETWEEN THE THE MOST STRICT STANDARD N ( (I IN THE OPINION OF THE ENGINEER) HALL ) ' APPLY. THE ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS, A.H.J. AND THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST. Q THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. ® ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM TO WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANELBOARD. © THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. ® THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:OOPM AND 5:00AM. TELEPHONE SYSTEM NOTES: ® AT START OF CONSTRUCTION, GNOC (GLOBAL NETWORK OPERATIONS CENTER) WILL ORDER PHONE SERVICE, CM TO SUBMIT FORM VIA EMAIL TO THE GNOC GROUP AT GNOC@STARBUCKS.COM ® STORES REQUIRE A MINIMUM OF FIVE OR SIX(SEE BELOW) PHONE LINES TERMINATED AT THE DEMARC BOARD IN THE BACK OF HOUSE NEAR THE MANAGER'S DESK AND THE TECHNOLOGY RACK. PHONE UNE ASSIGNMENTS CAN BE FOUND ON THE STORE DELIVERY SCHEDULE. THEY ARE TO BE TERMINATED AND LABELED IN THE FOLLOWING ORDER AND USE. LINE #1 — VOICE UNE FOR MAIN LISTED PHONE NUMBER AND ALARM PANEL. ROUTE THE CABLE FROM DEMARC TO RJ31X JACK ADJACENT TO INTERACTIVE SECURITY ALARM PANEL LABEL JACK AS "V1 —VOICE LINE W telephone number ALARM PANEL ". EXTEND CABLING FROM RJ31X TO THE MANAGER S DESK AND EACH BARISTA PHONE LOCATION WITH AN RJ11 JACK. UNE #2 — VOICE UNE FOR ROLLOVER PHONE NUMBER. ROUTE CABLE FROM DEMARC TO A RJ11 JACK LOCATED AT THE MANAGER'S DESK. LABEL JACK AS "V2 —VOICE LINE W /telephone number". LINE #3 — DEDICATED LINE FOR DIAL UP MODEM FOR THE MANAGER'S PC WORKSTATION. ROUTE CABLE FROM DEMARC TO A RJ11 JACK ADJACENT TO THE BOH TECHNOLOGY RACK. LABEL JACK AS "MODEM LINE W /telephone number ". SEE DETAIL LINE #4 — DEDICATED LINE FOR THE INTERACTIVE SECURITY SYSTEM. ROUTE CABLE FROM • DEMARC TO A RJ11 JACK ADJACENT TO THE DIGITAL SECURITY RECORDER ON THE BOH TECHNOLOGY RACK. LABEL JACK AS "AUDIO LINE W /telephone number ". SEE DETAIL LINE #5 — DEDICATED LINE FOR THE VIDEO MODULE IN THE SECURITY ALARM PANEL. ROUTE CABLE FROM DEMARC TO A RJ11 JACK ADJACENT TO THE SECURITY ALARM PANEL. LABEL JACK AS "VIDEO LINE W /telephone number ". SEE LAN /POWER /SECURITY SYSTEM DIAGRAM. LINE CONFIRM IF 6TH LINE IS NEEDED WITH C.M. FOR INTERAC DEBIT SYSTEM. d COORDINATE THE WORK OF THIS SECTION WITH THE REQUIREMENTS OF STARBUCKS COFFEE COMPANY'S SECURITY SYSTEM INSTALLER. ® USING PHONE NUMBER ASSIGNMENT FROM THE STORE DELIVERY SCHEDULE, THE GC WILL CROSS CONNECT THE VOICE TELEPHONE LINES FROM THE PHONE COMPANY (LEC) INTERFACE (66 BLOCK) TO THE 110 HARDWARE IN THE MPOE. THE DATA CABLING VENDORS WILL CROSS CONNECT THE DSL /FRAME RELAY CIRCUITS. T- MOBILE / TI NOTES: ® THE CAT5 CABLE PINNED TO POSITION 13 -16 AT THE 110 BLOCK SHALL BE EXTENDED AND TERMINATED WITHIN TWO (2) FEET OF THE TECHNOLOGY (OR IT) RACK, INTO A J--BOX ATTACHED TO THE WALL, CONTAINING AN RJ48C JACK. THE RJ48C JACK SHALL BE LABELED "TMOBILE /T1 ". SECURITY SYSTEM NOTES: ® STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY & INSTALL THE SECURITY SYSTEM, CONTRACTOR TO SCHEDULE INSTALLATION OF SECURITY SYSTEM FOR TWO TIMES: ROUGH —IN PRIOR TO DRYWALL INSTALLATION AND FINAL TRIM PRIOR TO STORE TURNOVER. SECURITY VENDOR REQUIRES A MINIMUM TWO WEEKS LEAD TIME FOR EACH INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. SECURITY VENDOR THE DIEBOLD COMPANY CONTACT: DIEBOLD PROJECT MANAGEMENT, STARBUCKS NEW STORES PHONE: 206 - 318 -6688 EMAIL: starbuckediebold.com COMMUNICATION SYSTEMS NOTES: ® PROVIDE FOUR (4) CAT5 (WHITE) COMMUNICATION CABLES TO THE SPACE. ® FOUR (4) CAT5 CABLES ARE DEDICATED TO STORE OPERATIONS /COMMUNICATIONS. Q THE GC MUST INSTALL 110 HARDWARE (MINIMUM SIZE: 25pr) IN BOTH THE MPOE AND BOH. THE 110 HARDWARE IN THE BOH SHOULD BE PLACED ON THE BACKBOARD (PARTS RECOMMENDED: AVAYA 110DW 2 -25 — MFG PART# 107256653). THE SERVICE LOOP (30 FOOT) CAN BE SHORTENED TO ACCOMODATE THE PLACEMENT OF THE 110 HARDWARE. ALL FOUR (4) OF THE CAT5 CABLES MUST BE PUNCHED DOWN TO THE 110 HARDWARE AT THE MPOE AND BOH, TONED, TESTED AND LABELED AS INDICATED IN THE TABLE BELOW: CABLE PAIRS /POSITION LABELED 1 2 3 4 9 , -12 13 , -16 PIN WIRE COLOR 1 WHITE /ORANGE 2 ORANGE 3 WHITE /GREEN 4 BLUE 5 WHITE /BLUE 6 GREEN 7 WHITE /BROWN 8 BROWN V1, V2, V3, V4 V5, V6, V7, V8 DSL /FRAME RELAY T— MOBILE /T1 THE GC SHOULD PERFORM THE PUNCH DOWN AT THE MPOE AND THE BOH PER THE FOLLOWING 568b IN— BUILDING CAT5 CABLING STANDARD: SCOPE OF WORK NOTE: CONTRACTOR SHALL COORDINATE WITH LANDLORD AND OBTAIN A COPY OF THE TENANT CRITERIA MANUAL /SPECIFICATIONS AND ALL OTHER CONSTRUCTION REQUIREMENT DOCUMENTS FOR THIS PROJECT. CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH LANDLORD REQUIREMENTS /SPECIFICATIONS AND ADHERE TO THEM. LANDLORD'S SCOPE OF WORK: THE FOLLOWING ABBREVIATED SCOPE OF WORK SHALL BE COMPLETED BY THE LANDLORD'S CONTRACTORS AS SPECIFIED IN THE "LANDLORD WORK LETTER — EXHIBIT B AND TENANT CRITERIA MANUAL ". NOT ALL WORK IS NECESSARILY CALLED FOR IN THIS DESCRIPTION OR IN THESE PLANS. REFERENCE THE "LANDLORD WORK LETTER" AND "TENANT CRITERIA MANUAL" FOR A COMPLETE DESCRIPTION OF WORK SCOPE. THE LANDLORD SHALL 1. FURNISH AND INSTALL (F &I) POWER SERVICE(S) WITH 200 AMPS OF 480V/277V 30, 4W CAPACITY TO STARBUCK'S SPACE INCLUDING ALL METER(S), DISCONNECT(S), CONDUIT(S), WIRE AND MISCELLANEOUS AS SHOWN ON THESE PLANS. TERMINATE SERVICE IN A 200A FUSED SWITCH LOCATED PER THESE PLANS READY TO BE USED FOR TEMPORARY POWER. (STARBUCKS CONTRACTORS TO F &I TRANSFORMERS AND PANELS TO UTILIZE 480V TEMPORARY POWER). 2. LANDLORD TO FM COMMUNICATION TERMINAL BOARD IN ELECTRICAL ROOM FOR PHONE SYSTEM AND MAKE AVAILABLE A CABLE TRAP IN THE SERVICE CORRIDOR FOR CABLING. 3. F &I JUNCTION BOX WITHIN SPACE WITH CONDUIT FEED FOR ARE ALARM SYSTEM (CONFIRM SCOPE). STARBUCKS CONTRACTORS SCOPE OF WORK: STARBUCKS CONTRACTORS SHALL BE RESPONSIBLE FULLY OPERATIONAL ALL POWER, FIRE ALARM AND IN ADDITION, INCLUDE LANDLORD'S APPROVED FIRE THIS SPACE. FOR ALL WORK NOT COVERED IN ABOVE LANDLORD'S SCOPE OF WORK TO COMPLETE AND MAKE LIGHTING SYSTEMS. COORDINATE WITH STARBUCKS GC. ALARM CONTRACTORS COST TO DESIGN, FURNISH AND INSTALL THE FIRE ALARM SYSTEM FOR DSL /FRAME RELAY NOTES: A® THE DSL /FRAME RELAY VENDOR WILL INSTALL THE IN —HOUSE WIRING AND RJ45 JACK FOR THE DSL /FRAME RELAY SERVICES. NE CAT5 CABLE PINNED TO POSITIONS 9 , -12 AT THE 110 BLOCK SHALL BE EXTENDED AND TERMINATED WITHIN TWO (2) FEET OF THE TECHNOLOGY (OR IT) RACK INTO A J —BOX ATTACHED TO THE WALL CONTAINING AN RJ45 JACK. THE RJ45 JACK SHALL BE LABELED "DSL /FRAME RELAY LINE ". P05 / DATA LINE NOTES: ® STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY AND INSTALL CATEGORY 5 LAN CABLE AND CONNECTORS FOR THE POS SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. ® AT THE START OF CONSTRUCTION, STARBUCKS CM SCHEDULES DELIVERY OF CASH REGISTER /MANAGER'S WORKSTATION EQUIPMENT AND INSTALLATION BY A DATA CABLING TECHNICIAN FOR TWO DAYS PRIOR TO CONSTRUCTION END. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO WEEKS PRIOR TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE STORE, CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY, DO NOT REFUSE DELIVERY. © DATA CABLING TECHNICIAN TO PROVIDE ALL CATEGORY 5 LAN CABLING AND CONNECTIONS TO ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, AND MANAGER'S WORKSTATION. ®D DATA CABLING TECHNICIAN TO REMOVE PACKAGING, INSTALL AND TEST CASH REGISTERS, CASH DRAWERS AND MANAGER'S WORKSTATION. ® CONTRACTOR RESPONSIBLE FOR COORDINATION OF PHONE /DSL LINE INSTALLATION PRIOR TO DATA CABLING VENDOR'S WORK. ®F INTERAC PAYMENT METHOD (IF NEEDED) TO BE INSTALLED BY DATA CABLINE VENDOR. COORDINATE EXACT LOCATION FOR ELECTRICAL /PHONE LINES WITH PROJECT MANAGER. POS DELIVERY AND INSTALLATION CONFIRMATION CONTACT: NEWSTORE @STARBUCKS.COM FOR CURRENT DATA CABLING VENDOR CONTACT: NEWSTORE @STARBUCKS.COM MUSIC SYSTEM NOTES: ® PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS. CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM. MOUNT OWNER FURNISHED SPEAKERS. FOLLOW MANUFACTURERS INSTALLATION REQUIREMENTS. ELECTRICAL LEGEND $3 $M $K CD 0 D.L. m U.O.N. LL O.C.P. SWITCH THREE WAY SWITCH MOTION (OCCUPANCY) SENSOR SWITCH KEYED SWITCH SWITCHBANK SEE DETAIL ON E3.0 TELEPHONE THERMOSTAT THERMOSTAT SENSOR DIMMER DAY LIGHT ZONE SWITCHED SEPARATELY TIME CLOCK UNLESS OTHERWISE NOTED LANDLORD OVER CURRENT PROTECTION EXIT SIGN a JUNCTION BOX ® L.A.N. RECEPTACLE RECEPTACLE; 110 DUPLEX RECEPTACLE: ntr 110 DEDICATED - - GF1 RECEPTACLE: 110 DUPLEX GROUNDING ELECTRODE CONNECTION NL E F &I AHJ U.N.O. MDP RECEPTACLE: 110 QUAD RECEPTACLE: 208V OR 220V NIGHTLIGHTING 24 HR /DAY EXISTING FURNISH & INSTALL AUTHORITIES HAVING JURISDICTION UNLESS NOTED OTHERWISE MAIN DISTRIBUTION PANEL DISCONNECT SWITCH, FUSED, IF NEEDED CONCEALED RACEWAY: CONTRACTOR TO F &I APPROPRIATE OR QUANTITY OF CONDUCTORS BY SUMMING QUANTITIES CALLED OUT IN NOTES. IF NOTE DOES NOT CALL OUT 7Th QUANTITIES, F &I 2 #12 CU. MINIMUM PER DEVICE. F &I DEDICATED NEUTRAL FOR ALL GA CIRCUITS TO PREVENT FALSE TRIPPING. F &I A NEUTRAL FOR PHASE TO PHASE LOADS IF NEEDED FOR CONTROLS OR OTHER REASONS. F &I GROUND WIRE IN ALL PVC CONDUITS (NOT SHOWN). PVC CONDUITS ARE NOT ALLOWED IN MULTI FLOOR BUILDINGS WHERE CONDUIT IS EXPOSED TO AIR OR ABOVE GRADE FOR ANY BUILDING. ENERGY CODE CALCULATIONS SEE ATTACHED 8 -1/2 "x 11" SHEETS FOR ENERGY CODE CALCULATIONS LANDLORD REQUIREMENTS THE FOLLOWING LANDLORD REQUIREMENTS /SPECIFICATIONS IS AN ABBREVIATED OVERVIEW. IT IS THE CONTRACTORS RESPONSIBILITY TO OBTAIN, BECOME COMPLETELY FAMILIAR, AND ADHERE TO ALL OF THE LANDLORD'S REQUIREMENTS. WHERE LANDLORD REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS, LANDLORD REQUIREMENTS SHALL GOVERN. 1. PRIOR TO MAKING ANY PIPE OR DUCT ROOF PENETRATION OR CORE DRILL AND /OR POSTIONING OF ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS AS INDICATED ON LANDLORD — APPROVED PLANS AND APPROVED BY LANDLORD'S CONSTRUCTION FIELD COORDINATOR. 2. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGISHER (MINIMUM SIZE 2A:20BC), WHEREVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR THE LEAST ONE (1) HOUR AFTER COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. 3. FLEXIBLE CONDUIT CANNOT BE USED AS COMMON ROUTING FOR WIRES. IT IS LIMITED TO WITHIN CASEWORK AND FINAL CONNECTION OF EQUIPMENT AND LIGHT FIXTURES (4 FT. MAX). 4. ALL WIRING SHALL BE IN CONDUIT WITH TYPE PER CODE. NO MC CABLE (ETC.) IS ALLOWED. 5. CONDUIT RUNS SHALL BE SEPARATED BY 3" WHEREVER THEY RUN NEXT TO OR CROSS WATER OR GAS LINES. 6. ALL CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORT, ETC. SHALL BE MADE TO BAR JOISTS AND BEAMS. CONDUITS SHALL NOT BE SUPPORTED FROM ANY OTHER CONDUIT, DUCT, PIPE, ETC. 7. CAULK AROUND ELECTRICAL BOXES IN DEMISING WALLS TO REDUCE NOISE TRANSMISSIONS. 8. PROVIDE LOC —ON DEVICES ON PANEL CIRCUIT BREAKERS FOR EXIT, EMERGENCY LIGHT, AND FIRE /ALARM SYSTEMS. 9. TENANT'S ELECTRICAL CONTRACTOR SHALL F &I IDENTIFICATION NAMEPLATE ON TENANTS MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD (CONFIRM REQUIREMENTS). �aa - BIB STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SAECff1CATICNS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DEEMS ARE ThE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPROOUCIION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEN) WITHOUT STAMMKS' PRIOR WRITTEN CONSENT IS STRICTLY RIMMED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL.COM REV DATE JC DESCRIPTION CO CO CO Q Z Q - U 0 Z z 0 PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE ELECTRICAL SPECIFICATIONS SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER E1.0 NOTES PANEL A VOLTAGE: 208V/120V 3PH, 4W FED FROM: PANEL 'H' VIA TRANSFORMER BUS: 125 AMP MAIN BREAKER: 125A AIC RATING: 10K LOCATION: WORKROOM SERVES ESPRESSO MACHINE ESPRESSO MACHINE DISHWASHER 4,500 3,952 SPARE FOODCASE LIGHTS FOODCASE SPARE SPARE SPARE SALES AREA RECS TYPE LOAD K K K K K K L K K 840 R CKT BRKR AMP POLE 40/2 4o/2 50/2 20 /1 15 /1 20 /2 20 /1 20 /1 20 /1 20 /1 CKT NO. 1 3 5 7 9 11 20 /1 20 /1 20 /1 20 /1 20 /1 13 15 17 19 21 23 25 27 CKT LOAD 3,300 3,300 3,300 3,300 3,952 3,952 290 1,310 1,310 1,080 A PHASE LOADS B C 3,660 3,800 1,356 2,090 840 1,130 1,260 GFI GFl REC. IN WORKROOM ROOFTOP UNIT REC WORKROOM REC SPARE SPARE SPARE SPARE TOTAL KITCHEN LOAD TOTAL LIGHTING LOAD TOTAL NON -CONT. LOAD TOTAL RECEPTACLE LOAD TOTAL CONTINUOUS LOAD TOTAL HVAC LOAD LARGEST MOTOR LOAD TOTAL KVA TOTAL AMPS R R R 20 /1 20 /1 20 /1 20 /1 20 /1 20 /1 20 /1 PHASE CONNECTED WATTS = PHASE CONNECTED AMPS = CONN. KVA = 31.74 = 1.49 = 0.50 = 5.90 = 0.00 0.00 = 0.00 1 39.6 1 29 31 33 35 37 39 41 180 180 1,200 DEMAND FACTOR X 0.65 X 1.25 X 1.0 x to X 1.25 X 1.0 X 1.25 1,380 0 13,126 109 1,700 0 13,382 112 28.9 1 CONN. DEMAND = 110 MPS = I 80 4,500 3,952 2,150 840 1,680 0 0 13,122 109 DEMAND KVA - 20.63 • 1.86 • 0.50 5.90 UNDER 10KW = 0,00 • 0.00 • 0.00 CKT LOAD 360 1,200 1,200 500 1,356 840 840 780 840 840 840 180 1,500 1,200 500 CKT NO. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 K= L NC = R = CL H= LM = AMPS©208V /120V 3PH, 4W CKT BRKR AMP POLE 20 /1 20 /1 15/1 15/1 20 /1 15 /1 15/1 15/1 20 /1 20 /1 20 /1 20 /1 20 /1 20 /1 20 /1 20 /1 LOAD TYPE KEY: TYPE LOAD R R R NC K K K K K K K K L R KITCHEN LOAD LIGHTING LOAD NON - CONTINUOUS LOAD RECEPTACLE LOAD CONTINUOUS LOAD HVAC LOAD LARGEST MOTOR LOAD SERVES PHONEBOARD MANAGERS DESK MANAGERS DESK MANAGERS DESK SPARE SPARE HOT TAP @ BARISTA UC REFER 0 BARISTA UC REFER ® BARISTA FRAPP /LABELER /WARMERS UC REFER UC REFER UC REFER LABELER GRINDER SIGNAGE MISC. LIGHTS / RECS FOR HVAC SPARE SPARE SPARE SPARE NOTES GFI GFI GA GF1 GA GFI GFI GFl GFl GFl GFl GFI GA GFl GFl NOTES: GFI - F &I GFI BREAKERS AND DEDICATED NEUTRALS FOR THESE CIRCUITS TO PREVENT FALSE TRIPPING. EQUIPMENT AIC RATINGS SHALL EXCEED THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUCTION. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO OMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC (FOR GFI BREAKERS), COORDINATE WITH LANDLORD. PANEL SCHEDULE 'A' NTS PANEL H VOLTAGE FED FROM: BUS: 480V/277V 3PH, 4W MAIN ELECTRICAL ROOM 200 AMP MAIN BREAKER: M.L.O. AIC RATING: 18K LOCATION: WORKROOM SERVES TYPE LOAD CKT BRKR 20 /1 POLE VAV -1 FAN VAV -1 HEATER H H H SPARE SPARE SPARE AMP I NOTES SPARE SUBFEED TO PANEL 'A' VIA TRANSFORMER 20/2 20 /1 20 /1 20 /1 20 /1 6o/3 CKT NO. 1 3 5 7 9 11 13 15 17 19 CKT LOAD 1,524 3,000 3,000 13,382 13,122 13,126 PHASE LOADS A B C 1,524 460 2,016 24,951 3,000 2,016 25,935 3,460 2,016 26,887 CKT LOAD 460 460 2,016 2,016 2,016 CKT NO. 2 4 6 8 10 12 14 12,553 13,765 11,825 16 18 20 CKT BRKR AMP POLE 20/1 20 /1 15/2 15/3 60 /3 TYPE LOAD H H H H H SERVES SPARE SPARE AMU -1 CU -1 SUBFEED TO PANEL 'B' VIA TRANSFORMER TOTAL KITCHEN LOAD TOTAL LIGHTING LOAD TOTAL NON -CONT. LOAD TOTAL RECEPTACLE LOAD TOTAL CONTINUOUS LOAD TOTAL HVAC LOAD LARGEST MOTOR LOAD TOTAL KVA TOTAL AMPS PHASE CONNECTED WATTS = 28,951 30,951 32,363 PHASE CONNECTED AMPS = 105 112 117 CONN. KVA - 63.93 • 2.96 • 2.30 • 7.08 ▪ 1.50 14.49 • 0.00 I92.3I CONN. = 111 AMPS DEMAND FACTOR X 0.65 X 1.25 X 1.0 X 1.0 x X K 1.25 1.0 1.25 DEMAND KVA 41.55 3.70 • 2.30 • 7.08 UNDER 10KW • 1.88 14.49 • 0.00 1 71.0 LOAD TYPE KEY: K - L = NC = R = CL = H= LM = DEMAND • I 86 IAMPS©480V /277V 3PH, 4W KITCHEN LOAD UGHI1NG LOAD NON - CONTINUOUS LOAD RECEPTACLE LOAD CONTINUOUS LOAD HVAC LOAD LARGEST MOTOR LOAD NOTES NOTES: GFI - F &I GFI BREAKERS AND DEDICATED NEUTRALS FOR THESE CIRCUITS TO PREVENT FALSE TRIPPING. EQUIPMENT AIC RATINGS SHALL EXCEED THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUCTION. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO OMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC ( FOR GFI BREAKERS). COORDINATE WITH LANDLORD. PANEL SCHEDULE 'H' NOTES GFI on GA GFI GFI GFI GFI GFI PANEL B VOLTAGE: 208 V /120V 3PH, 4W FED FROM: PANEL 'H' VIA TRANSFORMER BUS: 125 AMP MAIN BREAKER: 125A AIC RATING: 101( LOCATION: WORKROOM SERVES DISPLAY LIGHTS GENERAL LIGHTS SPARE BLENDER SPARE OUTLET FOR BLENDER BLENDER SPARE OUTLET FOR BLENDER SPARE ROLL -UP GRILLE DOOR ROLL -UP GRILLE DOOR REACH -IN REFER ICE MACHINE SPARE BLANK BLANK BLANK BLANK BLANK BLANK BLANK TOTAL KITCHEN LOAD TOTAL LIGHTING LOAD TOTAL NON -CONT. LOAD TOTAL RECEPTACLE LOAD TOTAL CONTINUOUS LOAD TOTAL HVAC LOAD LARGEST MOTOR LOAD TOTAL KVA TOTAL AMPS TYPE LOAD L L K R K R R K K K CKT BRKR AMP POLE 20 /1 20 /1 20 /1 20 /1 20 /1 I 38.1 CKT NO. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 CONN. DEMAND KVA FACTOR = 32.19 X 0.65 1.47 X 1.25 = 1.80 X 1.0 = 1.18 X 1.0 1.50 X 1.25 • 0.00 X 1.0 = 0.00 X 1.25 CONN. = 106 AMPS CKT LOAD 660 813 1,560 90 20 /1 20 /1 1,560 90 20 /1 20 /1 500 20 /1 20 /1 500 1,200 1,435 15/1 20 /2 1,435 PHASE CONNECTED WATTS PHASE CONNECTED AMPS = PHASE LOADS A B C 840 4,510 3,040 2,000 1,435 0 0 11,825 99 1,713 3,040 2,500 5,300 0 0 0 12,553 105 DEMAND KVA 20.92 1.84 1.80 1.18 1.88 0.00 0.00 27.6 DEMAND 720 4,510 3,000 5,535 0 0 0 13,765 115 UNDER 10KW CKT LOAD 180 900 720 2,950 2,950 2,950 2,950 2,500 2,500 1,500 4,100 4,100 CKT NO. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 L NC R CL H LM 77 IAMPS0208V /120V 3PH, 4W CKT BRKR AMP POLE 20 /1 20 /1 20 /1 30 /2 30 /2 30 /2 20 /1 50/2 TYPE LOAD NC NC NC CL LOAD TWE KEY: K = KITCHEN LOAD UGHT1NG LOAD = NON-CONTINUOUS LOAD = RECEPTACLE LOAD = CONTINUOUS LOAD = HVAC LOAD = LARGEST MOTOR LOAD SERVES SAFE POS EQUIPMENT WARMING OVEN WARMING OVEN HOT WATER TANK LCD/SERVER MN BREWER BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK NOTES GFI GFI GA - F&I GA BREAKERS AND DEDICATED NEUTRALS FOR THESE CIRCUITS TO PREVENT FALSE TRIPPING. EQUIPMENT AIC RATINGS SHALL EXCEED THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUCTION. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO LIMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC (FOR GFI BREAKERS). COORDINATE WITH LANDLORD. PANEL SCHEDULE 'B' NTS pos---010 DISCONNECTS AND FUSED SWITCHES FUSED SWITCHES HEAVY DUTY TYPE, HORSEPOWER RATED WITH INTERLOCKING COVER. NEMA 1 TYPICAL OUTDOOR AND WET LOCATION SWITCHES SHALL BE RAINTIGHT TYPE NEMA 3R. ALL SWITCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600 AMPERES OR LESS SHALL BE UL CLASS RK1 DUAL-ELEMENT, TIME DELAY, CURRENT LIMITING FUSES. FUSES IN CIRCUITS RATED AT 601 AMPERES OR LARGER SHALL BE UL CLASS L TIME-DELAY, CURRENT LIMITING SWITCHES. NAMEPLATES PROVIDE PERMANENT NAMEPLATE LABELING ON ALL DISCONNECTS AND PANELS. INCLUDE LOAD SERVED, VOLTAGE, PHASE, HORSEPOWER, FUSE SIZE, AND TYPE. FOR PANELS, INCLUDE DESIGNATION (SUCH AS "PANEL A MOUNTING MOUNT DISCONNECTS INDEPENDENTLY OF THE MECHANICAL UNIT HOUSING UNLESS SPECIFICALLY ACCEPTED BY THE LOCAL CODE AUTHORITY. PROVIDE UNISTRUT SUPPORT CHANNELS MOUNTED IN COORDINATION WITH ROOF PENETRATION AND PATCHING WORK. COORDINATE WITH GENERAL CONTRACTOR. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES, SHALL BE PROPERLY GROUNDED. METAWC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS TO PROVIDE GROUND PANELBOARDS PROVIDE BRANCH CIRCUIT PANELBOARD(S) AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. PANELBOARDS SHALL HAVE PLUG-IN BREAKERS AND MAIN LUGS ONLY OR MAIN BREAKERS AS REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED WITH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 TYPE RECESSED HOUSING AS MANUFACTURED BY "SQUARE D", "ITE", OR EQUAL AND CAPABLE OF ACCEPTING GFI BREAKERS. ENCLOSURE(S) SHALL BE COMPETE WITH A HINGED DOOR, CYLINDER LOCK, AND A NEATIY TYPED DIRECTORY UNDER PLASTIC COVER IN EACH PANEL DOOR. ALL MULTIPLE POLE BREAKERS SHALL HAVE A COMMON TRIP HANDLE. FOR EXISTING PANELS SHOWN TO BE REUSED OR RELOCATED, PROVIDE ANY NEW BREAKERS NECESSARY. LIGHTING INSTALL A NEW (U.N.0.) LIGHTING SYSTEM COMPLETE AND FULLY OPERATIONAL AND IN CONFORMANCE WITH CODE AND UL LISTING REQUIREMENTS. CLEAN ALL FIXTURES AT TIME OF JOB COMPLETION UTILIZING MANUFACTURERS APPROVED OR RECOMMENDED CLEANING SOLUTIONS. ALL FIXTURES AND LAMPS ARE SELECTED, APPROVED AND SUPPLIED BY STARBUCKS AS SCHEDULED ON ARCH. SHEETS UNLESS NOTED OTHERWISE. CONDUCTORS AND TERMINATIONS CONDUCTORS CONDUCTORS SHALL BE COPPER, INSULATED FOR 600V. TYPE THWN/THHN. NUMBER 12 AWG MINIMUM. MOTORS AND OTHER WIRING THE ELECTRICAL CONTRACTOR SHALL PROVIDE AL NEEDED CONDUIT, WIRING, AND SAFETY SWITCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN THOUGH THE MOTORS AND EQUIPMENT, MAY BE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. SHALL BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQIPMENT. ELECTRICAL CONTRACTOR SHALL INCLUDE AL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL THE EQUIPMENT MAY INCLUDE BUT IS NOT LIMITED TO SUCH ITEMS AS MOTORS AND INTERLOCKS, STOREFRONT AND OTHER SIGNAGE, STARTING DEVICES, MOTOR CONTROLLERS, FLOAT SWITCHES, ALARM DEVICES OR SYSTEMS, PUSH BUTTONS, EXHAUST FANS, DATA SYSTEMS, INTERCOMS, SOUND SYSTEMS, AND OTHER APPLIANCES. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT BEFORE INSTALLING THE CONDUIT OR OUTLETS. LOW VOLTAGE AL LOW VOLTAGE WORK SHALL COMPLY, BE PERMITTED AND INSPECTED PER STATE AINID AHJ) REQUIREMENTS. ALL LOW VOLTAGE WORK SHALL BE INSTALL D BY A LICENSED CONTRACTOR IN ACCORDANCE WITH THE STATE AND AHJ REQUIREMENTS. ALL LOW VOLTAGE CABLING INSTALLED UNDERGROUND SHALL BE ROUTED IN A CONDUIT RACEWAY AND CABLING/CONDUCTORS SHALL BE LISTED FOR USE IN MET LOCATIONS AND FOR LOW VOLTAGE APPLICATION PER AHJ. ALL LOW VOLTAGE CABLING ROUTED INDOORS SHALL BE ROUTED CONCEALED IN WALLS/CEILINGS IN A CONDUIT RACEWAY (UNLESS STARBUCKS CM AND AHJ AUTHORIZE IT TO BE ROUTED EXPOSED THROUGH WAL/CEILING). IF APPROVED BY STARBUCKS CM & AHJ TO BE ROUTED EXPOSED, CABLING SHALL BE PROPERLY FASTENED/SUPPORTED PER CODE, AHJ, AND INDUSTRY STANDARDS. CABLING NOT ROUTED IN CONDUIT SHALL BE PLENUM RATED WHERE REQUIRED BY CODE OR AHJ (CONFIRM WHETHER CEILING SPACE IS BEING USED AS AN AIR PLENUM.) ALL LOW VOLTAGE CABUNG OUTDOORS SHALL BE ROUTED IN CONDUIT PER CODE AND AHJ REQUIREMENTS. ELECTRICAL SPECIFICATIONS SCOPE PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. TEMPORARY POWER THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL WIRING FOR CONSTRUCTION. THE TEMPORARY SERVICE SHALL BE A MINIMUM OF 60 AMPS, SINGLE PHASE, THREE WIRE, 120/208 VOLTS (OR 120/240V IF 120/208V IS NOT AVAILABLE) FUSED AT MAIN DISCONNECT. ALL RECEPTACLES ON THIS TEMPORARY SERVICE SHALL BE PROTECTED BY A GFI BREAKER. MECHANICAL EQUIPMENT ALL FINAL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. BASIC MATERIALS AND METHODS MATERIALS PROVIDE AL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWISE. ALL EQUIPMENT SHALL BE UL APPROVED AND LABELED, OR OTHER APPROVED TESTING ORGANIZATION WHICH HAS ACCEPTANCE BY THE AUTHORITIES HAVING JURISDICTION (AHJ) FOR THE PURPOSE FOR WHICH THEY ARE USED, IN ADDITION TO MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS. NO SUBSTITUTION TO MATERIALS SPECIFIED WILL BE ALLOWED UNLESS NOTED OTHERWISE. ALL ITEMS ARE NEW UNLESS OTHERWISE NOTED (UON). CUT1ING AND FITTING PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF 'THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT OF THIS SECTION. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE STARBUCKS CONSTRUCTION MANAGER AND LANDLORD. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS, AND CASEWORK. RACEWAYS PROVIDE CODE APPROVED WIRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT AND COPPER CONDUCTORS. ALL ABOVE GROUND CONDUITS SHALL BE EMT OR RIGID. PVC CONDUITS ARE NOT ALLOWED IN MULTI FLOOR BUILDINGS WHERE CONDUIT IS EXPOSED TO AIR OR ABOVE GRADE FOR ANY BUILDING. CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE CONCEALED AND BE RIGID STEEL CONDUIT WITH WEATHER TIGHT, CORROSION-RESISTANT FITTINGS. SCHEDULE 40 PVC IS ACCEPTABLE WHERE PERMITTED BY CODE AND AHJ, FOR UNDERGROUND RUNS OR CONCRETE ENCASEMENT WHERE NOT EXPOSED TO PHYSICAL DAMAGE. CONDUIT SHALL NOT BE RUN EXPOSED WITHOUT SPECIFIC PERMISSION FROM THE CONSTRUCTION MANAGER. THE MINIMUM SIZE OF CONDUIT SHALL BE 1/2" UNLESS OTHERWISE NOTED. CONDUIT RUNS CONCEALED IN CONCRETE OR UNDERGROUND. SHALL BE 3/4" MINIMUM, UNLESS OTHERWISE NOTED. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. RIGID CONDUIT SHALL BE HOT DIPPED GALVANIZED. BRANCH CIRCUIT WORK CHASED INTO EXISTING CONSTRUCTION FOR CONCEALMENT UNDER PATCHED FINISHES SHAL BE INSTALLED IN RIGID CONDUIT, OR EMT. WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRING. PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T&B FLAMESAFE OR OTHER METHOD APPROVED BY THE STARBUCKS CONSTRUCTION MANAGER. SWITCHES AND RECEPTACLES SWITCHES SLATER OR APPROVED EQUAL WITH MATCHING COVERPLATES UNLESS NOTED OTHERWISE. SEE RECEPTACLES SLATER OR APPROVED EQUAL WTH MATCHING COVERPLATES UNLESS NOTED OTHERWISE. SEE E2.0. INSTALL RECEPTACLES WITH GROUND PIN FACING IN A DIRECTION PER THE GENERAL CONTRACTOR. PROVIDE GFCI TYPE TYPE WHERE INDICATED. SHOW WINDOW RECEPTACLES SHALL BE PAINTED TO MATCH ADJACENT SURFACE. OCCUPANCY SENSORS (FOR SITES HAVING RESTROOMS) WATTSTOPPER, UNLESS NOTED OTHERWISE, FOR USE IN ALL TOILET ROOMS. SEE E2.0 AND CONDUCTORS AND TERMINATIONS CONDUCTORS CONDUCTORS SHALL BE COPPER, INSULATED FOR 600V. TYPE THWN/THHN. NUMBER 12 AWG MINIMUM. MOTORS AND OTHER WIRtNG THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, WIRING, AND SAFETY SWITCHES FOR AL MOTORS, AND EQUIPMENT, EVEN THOUGH THE MOTORS AND EQUIPMENT, MAY BE SUPPLJED BY OTHERS. MOTORS, CONTROLS, ETC. SHALL BE FURNISHED BY THE SUPPLIER OF NE DRIVEN EQIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL THE EQUIPMENT MAY INCLUDE BUT IS NOT LIMITED TO SUCH ITEMS AS MOTORS AND INTERLOCKS, STOREFRONT AND OTHER SIGNAGE, STARTING DEVICES, MOTOR CONTROLLERS, FLOAT SWITCHES, ALARM DEVICES OR SYSTEMS, PUSH BUTTONS, EXHAUST FANS, DATA SYSTEMS, INTERCOMS, SOUND SYSTEMS, AND OTHER APPLIANCES. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE,AND VENDOR SUPPLYING THE EQUIPMENT BEFORE INSTAWNG THE CONDUIT OR OUTLETS.. STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 RIESE PLANS AND SPECEICATIONS, AS WEIL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE E<CWSINE PROPERTY OF STARSUCXS CORPORATION. ANY RPRODUCTION. MODIRCATICN, DISCLOSURE AND/OR USE CF RESE MATERIALS (OR ANY POCRON OF THEM) IS STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739-6051 (425) 739-7362 REV DATE JC DESCRIPTION cci co O z FI S" <- 0 0 O Z U c a 0 LIJ 8 PROJECT #: 12197-001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE PANEL SCHEDULES a ELECTRICAL SPECIFICATIONS (DO NOT SCALE DRAWINGS) SHEET NUMBER EI.1 5 co OD IL rr POWER PLAN FLAG NOTES PROVIDE ALL BRANCH CIRCUITING AND DEVICES, EVEN IF NOT SHOWN. PROVIDE ALL WIRING AND WIRE QUANTITIES TO ACCOMPLISH CIRCUITING TO MEET SPEC REQUIREMENTS AND APPLICABLE CODES. OWNER PROVIDED SPEAKER. MOUNT AT ELEVATIONS PER GENERAL CONTRACTOR. F &I ANY NEEDED CONDUITS AND CONDUCTORS (NOT SHOWN). FLAG NOTE NOT USED. 4 PROVIDE WALL PENETRATIONS AND ELECTRICAL CONNECTIONS AS NEEDED FOR SIGN. FLAG NOTE NOT USED. CONFIRM REQUIREMENTS. RUN ALL CONDUITS CONCEALED. FLAG NOTE NOT USED. 8 RUN CONDUITS CONCEALED IN SOFFIT, WALL, CEILING OR BELOW SLAB IF APPLICABLE. 9❑ IF ANY CORD AND PLUG IS OBSTRUCTED BY CABINET PARTITIONS, PROVIDE ADDITIONAL OUTLET. 10 SEE ARCH. SHEETS FOR EXACT LOCATIONS OF SIGNS. VERIFY ACTUAL RATINGS, OF CIRCUITS, BREAKERS AND CONNECTIONS IN FIELD. NOTES: 1. CEILING SPACE IS BEING USED AS A RETURN AIR PLENUM. F &I WIRING PER CODE AND LANDLORD REQUIREMENTS. 2. F &I WRING & MISCELLANEOUS FOR HVAC CONTROL SYSTEM NOT SHOWN. COORDINATE WITH GENERAL. NOTE: WIRE QUANTITIES ARE NOT SHOWN. FURNISH & INSTALL PER CODE WITH DEDICATED NEUTRALS FOR ALL GFI BREAKER PROTECTED CIRCUITS (TO PREVENT FALSE TRIPS). IN ADDITION, FURNISH AND INSTALL GROUND WIRE IN ALL PVC CONDUITS. ALL IS NEW UNLESS NOTED OTHERWISE. > FLAG NOTE NOT USED. FLAG NOTE NOT USED. PROVIDE RECEPTACLE FOR WARMING OVEN. COORDINATE WITH OVEN MANUFACTURER FOR NEMA RECEPTACLE TYPE. (F &I #10 CU. CONDUCTORS). CONFIRM VOLTAGE REQUIREMENTS FOR ALL EQUIPMENT. IF NEEDED THE CONTRACTOR SHALL PROVIDE AND INSTALL BUCK BOOST TRANSFORMERS TO BE LOCATED IN AN ACCESSIBLE LOCATION ABOVE THE CEILING WITHIN 6' OF THE ELECTRICAL PANEL. IF LOCAL CODES DO NOT ALLOW INSTALLATION ABOVE CEILING, THE TRANSFORMERS SHALL BE MOUNTED TO THE WALL JUST BELOW THE CEILING. ACCEPTABLE TRANSFORMERS INCLUDE ACME. F &I ANY NEEDED ADDITIONAL O.C.P. > 4 -PLEX FOR PHONE BOARD ABOVE CEILING (CONFIRM LOCATION OF BOARD AND OUTLET). NOT ALL SWITCHES ARE NECESSARILY SHOWN. ON GROUND FLOOR OF STARBUCKS BUILDING. SEE NOTES FOR MOUNTING ELEVATION. SEE LAN /POWER /PHONE /SECURITY SYSTEM DIAGRAM FOR CIRCUITING. PROVIDE GFI RECEPTACLE, SWITCH AND LIGHT NEXT TO HVAC UNIT PER BUILDING CODE REQUIREMENTS. F &I INDEPENDENT SUPPORT IF NEEDED. COORDINATE RECEPTACLES, SWITCHES AND LIGHTING LOCATIONS WITH SERVICE SIDE OF UNITS. A -32 VIA (- 4 > TYP POWER PLAN GENERAL NOTES O FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. 0 ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. Q DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. O REFER TO DETAIL SHEETS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. Q THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL VOLTAGE REQUIREMENTS ON ALL EQUIPMENT AND PROVIDING BUCK -BOOST TRANSFORMERS AS MAY BE NEEDED FOR CODE. ALL ARE NOT NECESSARILY INDICATED. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PLUMBING AND HVAC CONTRACTORS FOR ANY ADDITIONAL EQUIPMENT NEEDING POWER. Q ALL FUTURE EQUIPMENT NEEDED HEREIN SHALL BE PROVIDED WITH AN APPROPRIATE RECEPTACLE AND FULLY WIRED. EVEN IF NOT SPECIFICALLY INDICATED. e 0 Ems, QA Avavz W 2 � 6 10 I 1 TO LCD MONITOR 0 d -19 ! A_ t Q Q 11 1k 20 W 22 4('+ rl`'1i;:) Mi • 1` ii) i+ iD ti 4 L - 7,9,11,13 \ L � �J I A- 14,16,18 0 15 A-20,22,24 11 >> (TYPICAL) BACKBAR 14 TYPICAL 04( crivArr 0 0 -2,4,6 TO SECURITY EANFI SALES B -12,14 L - 6,28 A- 15,1,19 A 30 • X11 '-Nib CI L • Q 0 00 27 TO SECURITY PANEL 5KV TRANSFORMERS A JUNG ON PL B -17 A -27 3 27 27 B--1 OVE FORM NOT ALL CONDUITS /CIRCUITS CALLED FOR IN NOTES ARE SHOWN IN PLAN VIEW. 1 2 3 4 TO SERVER SEATING 1 D Q ADL7 11 (CONFIRM IF POWER IS REQUIRED) ELECTRICAL POWER PLAN 8 12 POWER PLAN KEY NOTES 37 ROLL -UP GRILLE DOOR: FURNISH AND INSTALL ELECTRICAL CIRCUIT. ROUTE CIRCUIT CONCEALED FROM PANELBOARD TO EACH DOOR. F &I INTERIOR AND EXTERIOR DOOR SWITCHES /KEYS AND CIRCUITS (NOT SHOWN). CONFIRM POWER, CONTROL AND SWITCH REQUIREMENTS. 38 FURNISH & INSTALL NEMA 6 -30R RECEPTACLE © 28" AFF, & ALL NECESSARY CONDUIT, WIRE ( #10) & CONNECTIONS BACK TO SERVING PANEL TO SUPPORT WARMING OVEN. 39 SURE -SHOT DISPENSERS: PROVIDE RECEPTACLE @ 26" AFF. 40 CUP LABELER - FURNISH AND INSTALL BACKBOX FOR DATA OUTLET AT 26" AFF. ROUTE (1) 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL STRING FROM END TO END. CONDUIT NOT SHOWN (TYPICAL). ® PROVIDE ELECTRICAL CONNECTION TO WATER HEATER. CONFIRM ELECTIRICAL REQUIREMENTS PRIOR TO ROUGH IN. 42 LCD MONITOR: PROVIDE RECEPTACLE AND J--BOX FOR VIDEO CABLE. ROUTE 1" CONDUIT FROM LCD J -BOX TO J -BOX ADJACENT TO NOW PLAYING SERVER AND PROVIDE END TO END PULL STRING. 43 NOW PLAYING SERVER: PROVIDE RECEPTACLE AND J -BOX FOR VIDEO CABLE. INTERCEPT CONDUIT FROM LCD MONITOR LOCATION. 200A 480V 30 FUSED DISCONNECT SWITCH BY LANDLORD (CONFIRM). LANDLORD FURNISH & INSTALLED 480V FEEDER FROM MAIN ELECTRICAL ROOM (CONFIRM). 208V RECESSED ELECTRICAL PANEL TIMECLOCK 36 SWITCHBANK LOCATION -20 VAV UNIT ABOVE CEILING (CONFIRM POWER REQUIREMENTS AND F &I DISCONNECT SWITCH IF NEEDED). 1"C FOR PHONE SYSTEM - EXTEND CONDUIT THRU ADJACENT TENANT'S SPACE (TIGHT TO STRUCTURE) TO SERVICE CORRIDOR WHERE CABLE TRAY IS LOCATED WITH PULLSTRING (CONFIRM). (ABOVE CEILING) 208V RECESSED ELECTRICAL PANEL 480V RECESSED ELECTRICAL PANEL 'H' CONTRACTOR TO COORDINATE WITH PM FOR COLOR OF OUTLETS, SWITCHES AND FACE PLATES IN CUSTOMER AREA AND IN RESTROOM. 0 a NUMBER NOT USED. RETAIL GRINDER: PROVIDE RECEPTACLE a 26" AFF. TWIN BREWER: NEMA 14 -50R RECEPTACLE e 26" AFF, 3/4 "C -30 AND 1 #10 GROUND, CONTRACTOR TO PROVIDE A NEMA 14 -50P CORD CAP FOR THE BREWER, BRYANT OR EQUAL. Q FOR ESPRESSO MACHINE, FURNISH AND INSTALL NEMA 6 -50R RECEPTACLE HUBBELL HBL9367 SERIES OR EQUAL AT 30" AFF. ROUTE 3/4" CONDUIT - (2) #6 AND (1) #10 GROUND FROM MACHINE BACK TO PANEL. FURNISH AND INSTALL NEMA 6 -50P ANGLED PLUG, HUBBELL HBL9368 SERIES OR EQUAL. 10 11 12 13 14 0 0 17 18 0 21 22 23 0 26 • 0 0 0 0 0 0 0 UNDER COUNTER REFRIGERATOR: PROVIDE RECEPTACLE @ 26" AFF. REFRIGERATOR AND /OR FREEZER: RECEPTACLE AT 84" AFF. ICE MACHINE (AIR COOLED): PROVIDE NEMA RECEPTACLE. FOODCASE: HARD WIRE EQUIPMENT CONNECTION. PROVIDE SEPARATE (1) 120V 15A AND (1) 220V 20A DEDICATED CIRCUITS. DISHWASHER (HIGH TEMP): NEMA 14 -50R RECEPTACLE a 18" AFF, 3/4 "C - 3#6 AND 1 #10 GROUND. RECEPTACLE a 18" AFF. F &I TELEPHONE JACKS AND WIRING AT EACH LOCATION IF WIRELESS ACCESS IS NOT AVAILABLE. NUMBER NOT USED. COFFEE WARMERS AND /OR SCALE: PROVIDE RECEPTACLE a 26" AFF. BLENDERS: PROVIDE A DUPLEX RECEPTACLE BOX AT 26" AFF ON A DEDICATED CIRCUIT FOR EACH BLENDER. MOUNT BOXES TO DIE -WALL BENEATH BLENDER CABINET. ALL BACK BAR AND FRONT BAR J -BOXES AND OUTLETS SHALL BE SURFACE MOUNTED. PROVIDE CONDUITS AS NEEDED AND (1) ADDITIONAL SPARE CONDUIT BETWEEN ALL J -BOXES FOR FUTURE ELECTRICAL REQUIREMENTS. ALL J -BOXES SHALL BE POSITIONED TO AVOID OBSTRUCTION OF ANY EQUIPMENT SUCH AS REFRIGERATORS AND DISHWASHERS. CONFIRM ALL THE ABOVE WITH GENERAL. LOCATION OF SWITCHING. PROVIDE ADDITIONAL OUTLET AND J -BOX ABOVE AS NEEDED FOR SECURITY SYSTEM ABOVE CEILING. FOR SIGNAGE, FURNISH AND INSTALL ELECTRICAL CIRCUIT. ROUTE CIRCUIT CONCEALED FROM PANELBOARD TO SIGNAGE. SAFE: FURNISH AND INSTALL DUPLEX RECEPTACLE AND SECURITY J -BOX AT 18" AFF. HOT TAP: PROVIDE RECEPTACLE AT 26" AFF. CIRCUIT VOLTAGE SHALL BE AT VOLTAGE RECOMMENDED BY EQUIPMENT MANUFACTURERS. IF NEEDED, THE CONTRACTOR SHALL PROVIDE AND INSTALL BUCK -BOOST TRANSFORMERS TO BE LOCATED IN ACCESSIBLE LOCATIONS ABOVE THE CEILING WITHIN 6' OF THE ELECTRICAL PANEL. IF LOCAL CODES DO NOT ALLOW INSTALLATION ABOVE THE CEILINGS, THE TRANSFORMERS SHALL BE MOUNTED TO THE WALL JUST BELOW THE CEILING. ACCEPTABLE TRANSFORMERS INCLUDE ACME. FURNISH AND INSTALL ANY ADDITIONAL O.C.P. NEEDED. NUMBER NOT USED. MANAGER'S DESK: PROVIDE LAN / POS ELECTRICAL DEVICES. SEE DETAILS FOR LOCATIONS AND EQUIPMENT. ALL REQUIRED OUTLETS ARE NOT NECESSARILY SHOWN. POS: FURNISH AND INSTALL DUPLEX ISOLATED - GROUNDING TYPE RECEPTACLE AT 18" AFF., INCLUDING GREEN GROUNDING WIRE AND ISOLATED GROUNDING WIRE BACK TO SERVING POWER PANEL PER CODE. FURNISH AND INSTALL (1) J -BOX FOR DATA OUTLET AND (1) J -BOX FOR PHONE OUTLET AT 18" AFF. NUMBER NOT USED. 4" SQUARE J -BOX MOUNTED ON 1/2" EMT CONDUIT a LOCATION SHOWN IN SEATING AREA FOR SECURITY SYSTEM STROBE LIGHT. MOUNT TO CEILING OR AT MAXIMUM HEIGHT IF EXPOSED STRUCTURE (NEVER ABOVE BAR UNO). ROUTE CONDUIT TO SECURITY ALARM PANEL LOCATION. ALARM KEYPAD AND EMERGENCY CALL PHONE: MOUNT c 54" AFF. ROUTE CONDUIT IN WALL FROM J -BOX AND STUB UP ABOVE CEILING. NUMBER NOT USED. PHONE PANEL ABOVE CEILING. RECEPTACLE FOR FUTURE USE. MOUNT BOX IN A HORIZONTAL ORIENTATION 96" AFF. DUPLEX CONVENIENCE RECEPTACLE a 48" AFF. STUB UP POWER, DATA, PHONE AND SECURITY CONDUITS 6" AFF IN THIS LOCATION AS INDICATED ELSEWHERE. ROUTE ABOVE FLOOR POWER CONDUCTORS IN FLEXIBLE METAL CONDUIT WITH GROUND TIGHT TO WALL FROM RECEPTACLES TO NEAREST RIGID STUB -UP AND BACK TO SERVING POWER PANEL. ROUTE DATA, PHONE AND SECURITY CONDUITS UNDERFLOOR BACK TO DATA RACK NEAR MANAGERS WORKSTATION. LABEL DATA AND PHONE CONDUITS "FOR DATA CABLING ", PROVIDE INSULATED BUSHINGS, AND PROVIDE PULL STRING FROM END TO END. LABEL SECURITY "CONDUIT FOR SECURITY" AND PROVIDE PULL STRING FROM END TO END. MUSIC SPEAKER: SEE ARCH. SHEETS FOR INSTALLATION LOCATIONS. NUMBER NOT USED. CUP LABELER: PROVIDE ISOLATED GROUND RECEPTACLE AND BACKBOX FOR LAN CONNECTION a 26" AFF. FURNISH AND INSTALL WEATHERPROOF, CFI, DUPLEX NEMA 5 -20R RECEPTACLE ON ROOF ADJACENT TO UNIT. MOUNT RECEPTACLE ON FREE - STANDING C- CHANNEL FRAME 18" ABOVE FINISH ROOF LEVEL. TIMECLOCK SHALL BE LOCATED ADJACENT TO THE POWER PANELS. FURNISH AND INSTALL ALL CONDUIT, WIRE, CONNECTIONS, CONTACTORS, ENCLOSURES, TIMECLOCK MODULES AND MISCELLANEOUS NECESSARY TO ENSURE A FUNCTIONAL TIMECLOCK SYSTEM. r , ‘j'vjQ STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -605I (425) 739 -7362 AERI23 @AOL.. CON REV DATE JC DESCRIPTION co co CO Q Z Q a a z a PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE ELECTRICAL POWER PLAN SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER E2.0 0 CD L :. CD C -- wU 5 2 -40A ESPRESSOS 1- REFERS(2 EA) /HOT TAP 1 -SPARE POWER (TYPICAL AT ALL CONDUIT STUB -UP LOCATIONS) OrdM L -- --^ * _ r Iii � I L , ' 1 ,USAF ,./'4 ; c 5z 4 f 1-SPA ice.. i 1-- BLENDER SCALA MSC E POVER SLAB ON GRADE - EXISTING GRADE BEAMS AND PILE CAPS BELOW SLAB (NOT ALL SHOWN). DO NOT PENETRATE CUT THESE EXISTING STRUCTURAL ELEMENTS. (CONFIRM REQUIREMENTS FOR CUTTING, BACKFILL AND PATCHING SLAB WITH LANDLORD'S ENGINEER). ROUTE ALL CONDUITS UNDER OR AROUND THESE ITEMS. 0 BACKBAR SEATING 2 3 4 1 -TWIN BREWER 1- REFER(2 EA) /LABELER/ FRAPP /WARMERS 2- WARMING 1 - REFER / 1 -SCALE ---- -------- \ 1 -LAN SPARE 1--LAN SAFE POS 1 -LAN POS PHONE 1 -LAN SPA E SALES 12 \ OVEN BELER 1-4 I Q `1- GRINDER 1�FOODCASE I I I WORKROOM 200A FUSED DISCONNECT SWITCH ELECTRICAL UNDERSLAB CONDUIT PLAN TIMECLOCK POWER PANELS C IT RACK © MANAGER'S DESK GENERAL NOTES: Q CONTRACTOR IS TO FURNISH AND INSTALL PULLSTRINGS THROUGH ALL CONDUITS. STUB CONDUITS UP IN LOCATIONS PER ARCHITECTURAL SHEETS. QUANTITIES OF CONDUITS PER THIS SHEET, NOT ARCHITECTURAL. OZ ALL UNDERSLAB (POWER & LAN) CONDUITS SHALL BE 3/4" PVC. U.O.N. ALL STUB UPS & ELBOWS FOR POWER, LAN & OTHER SHALL BE RIGID STEEL. 0 SEE PLUMBING PLANS FOR ADDITIONAL UNDER FLOOR ITEMS (TYPICAL). CD CONTRACTOR SHALL F &I CORE DRILLS, CONCRETE CUTTING, AND PATCHING TO STUB -UP RACEWAY THROUGH FLOOR SLAB. COORDINATE WITH STARBUCKS AND GENERAL CONTRACTOR TO DETERMINE SPECIFIC METHODS AND EXACT LOCATIONS. O PROTECT CONDUIT OPENINGS FROM CONTAMINANTS AFTER CONDUITS ARE INSTALLED AND PRIOR TO BACKFILL.. O IF POSSIBLE, ALL STUB UPS SHALL BE 4" OC MINIMUM. CONDUITS ROUTING TO POWER PANELS SHALL EXTEND UP WALL UNDER PANELS AND TERMINATE IN PANELS WITH APPROPRIATE FITTINGS AND BUSHINGS READY FOR WIRE TO BE PULLED BY OTHERS. F &I J- BOXES /WIREWAYS TO ACCOMPLISH THIS IF NECESSARY. O LABEL ALL CONDUITS SO VENDORS WILL KNOW WHICH CONDUITS TO USE, SUCH AS 'lO DT SIGNAGE" OR "TO SOUTH SIDE OF DT WINDOW FOR POS EQUIP ". CONDUCTORS ARE NOT SHOWN (TYPICAL). NOTE: 1. ALL BELOW GRADE CONDUITS SHALL BE SUPPORTED FROM SLAB WITH STAINLESS STEEL HANGERS PER CODE AND LANDLORD REQUIREMENTS. DO06- EXPIRES vaM1111f STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF' THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AER123 @AOL.COM REV DATE JC DESCRIPTION CD 0 c co co Z o) LLI Q >- Z O O 5 O CO CQ •• Z CD CO I- z 0 0 PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01 /28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE ELECTRICAL UNDERSLAB PLAN SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER E2.1 L900 3 LAMP FOR HAND OFF PEND - 75W SYLVANIA DIRECTOR COATED 120 75 SHATTER -PROOF 165935 VD L949 5 DULUX 18W COMPACT FLUOR SYLVANIA CFI8DDE827 120 18 W/ (3) L986 LAMPS 165939 VD L955 10 DULUX 18W COMP FLUOR COATED SHAT -R- SHIELD CF18DDE827 COATED 120 18 SHATTER RESISTANT REPLACEMENT FOR L949 192402 VD L956 11 60 PAR 30 LAMP COATED SHAT -R- SHIELD 60 PAR 30 /CAP /SPL /NFL25 130 60 LIGHTS IN FOOD PREP AREAS VD L986 15 48 IN LAMP FOR 2X4 OR STRIP SYLVANIA F032/S30ECO 120 32 119712 VD L145 11 TRACK FIXTURE WHITE JUNO R552WH 120 USES L956 LAMP 165935 VD L174 1 TRACK WHITE B' JUNO RBWH 120 W/ (3) L986 LAMPS 165939 VD L175 1 TRACK WHITE 4 JUNO R4WH USES FRAME L500 AND LAMP L949 120167 VD L500 11 DOWNLIGHT FRAME - 6 "DIA FLUOR LITHONIA LP6F 18DTT /TRT MVOLT 120 USES L949 LAMP 192404 VD L563 3 2X4 FOR ACT LITHONIA 2GT 332 Al2 120GEB 120 W/ (3) L986 LAMPS 119695 VD L961 11 RECESSED DOWN 6 "DlA LITHONIA 607A USES FRAME L500 AND LAMP L949 192405 VD L851 1 EMERGENCY LIGHT -WHITE LITHONIA 6ELM2 -SSB WHITE 120 CLUSTER OF 3 -L900 LAMPS 119703 VD L859 1 EXIT /EMERGENCY LIGHT BLACK LITHONIA LHQMS3G ELN - BLACK 120 W/ GREEN ILLUMINATED LETTERING VD L530 1 HAND OFF PENDANT CLUSTER IVORY RESOLUTE IVORY CLUSTER 120 CLUSTER OF 3 -L900 LAMPS 381903 3PL L037 4 FXTR PENDANT WHITE - DIMODA RESOLUTE WHITE HAND BLOWN 120 W/ L949 LAMP 1060444 3PL SWITCHBANK LOCATION 200A FUSED DISCONNECT SWITCH POWER PANELS LIGHTING PLAN SCHEDULE SEE NOTE 4 ITEM* QTY DESCRIPTION MANUFACTURER MODEL * VOLTS WATTS AMPS REMARKS SKU SHIP PENDANTS /SCONCES TRACK & TRACK FIXTURES FLUORESCENT FIXTURES ANCILLARY FIXTURES LOCALLY SOURCED LAMPS /BULBS ADDITIONAL ITEMS ADL5 3 FLOORESCENT LAMPS -STRIP LITHONIA W/ (2) L986 LAMPS LIGHTING SCHEDULE NOTES: 1. CONTRACTOR SHALL COORDINATE WITH SCHEDULE AND STARBUCKS TO ENSURE THAT ALL LIGHT FIXTURES IN FOOD PREP AREA ARE PROVIDED WITH SHATTER PROOF LAMPS OR LENSES 2. F &I PENDANTS AS MAY BE NEEDED. 3. CONFIRM LOCATION WITH STARBUCKS. 4. CONTRACTOR SHALL CONFIRM REQUIRED LETTER COLOR WITH AHJ. GC NOTE: CONDUCTOR QUANTITIES ARE NOT SHOWN. F &I PER CODE WITH SWITCHING AS INDICATED BY LETTER DESIGNATION, NOTE, OR LOCAL SWITCH. LIGHTING PLAN GENERAL NOTES Q PROVIDE A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. Q COORDINATE WITH GC AS TO WHOM IS TO PROVIDE ALL LIGHT FIXTURES AND LAMPS UNLESS NOTED OTHERWISE. 0 ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. a REFER TO ARCHITECTURAL CASEWORK DETAILS FOR EXACT LOCATIONS OF LIGHT FIXUTRES LOCATED IN CASEWORK. O. REFER TO ARCHITECTURAL PLANS FOR EXACT FIXTURE LOCATIONS. 0 CONFIRM ALL QUANTITIES IN SCHEDULE WITH THOSE IN PLAN VIEW. CONTRACTOR TO COORDINATE WITH PM FOR COLOR OF OUTLETS, SWITCHES AND FACE PLATES IN CUSTOMER AREA AND IN RESTROOM. LIGHTING PLAN KEY NOTES 0 TIMING DEVICE FOR SIGNAGE TO BE LOCATED ADJACENT TO POWER PANELS. COORDINATE WITH STARBUCKS FOR TIME ON /OFF AND PUT ON A 24HR /DAY LOCK ON CIRCUIT. THE TIMING DEVICE SHALL BE TORK SERIES Z, #Z7200. INTERIOR LOGOS, AND LIGHTS IDENTIFIED WITH " NI. " TO BE ON 24 HOUR PER DAY LOCK -ON CIRCUIT. Q NOT ALL SWITCHES ARE NECESSARILY SHOWN. Q ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS. Q RUN ALL CONDUITS CONCEALED (TYPICAL). COMMISSIONING REQUIREMENTS THE CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING CONTROLS THAT INCLUDE DAYLIGHT CONTROLS, AUTOMATIC SHUT -OFF CONTROLS, AND AUTOMATIC TIME SWITCHES WHERE INDICATED. TEST TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE AND STARBUCKS. TYP (MOUNT ABOVE TRANSLUCENT CEILING PANELS - CONFIRM) LIGHTING PLAN 2 12 SEE SCOPE OF WORK ON SHEET E1.0 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 T}IESE PLANS AND SPEJ}1CATIONS, AS YdaL AS STARBUcKS' NAME AND LOGO, TRADEMARKS AND DEEMS ARE THE EX LUW E PROPERTY OF STARBUDIS CORPORATION. MW REPRODUCTION, NODDlCA1tON, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) *MOUT STARDOMS' PRIOR %MEN CONSFIIT Is STRICTLY !VOMITED. CONSULTANTS AEI( ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23@AOL.COM REV DATE JC DESCRIPTION Co CO CO Q z J a 0 z 0 V PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE LIGHTING PLAN & SCHEDULE SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER E3.0 LU LL 'HOTSPOT' TELEPHONE LINES -2 CAT5 CABLES J BOX FOR T1 INTERNET CONNECTIONS- DEDICATED 1" EMT CONDUIT TO SECURITY (BY OTHERS). MOUNT 92" AFF. PROVIDE AN ORANGE COVER PLATE. PANEL J -BOX. Ti 'HOTSPOT' LINE -1 CATS CABLE I J BOX FOR TELECOMMUNICATION WIRING-MOUNT 3/4" EMT CONDUIT TO (BY OTHERS) I I ABOVE CEILING, ROUTE BACK TO DEMARC PANEL. I ��� SECURITY PANEL J -BOX. (2) 1" EMT CONDUITS FOR SECURITY AND VIDEO DSL /FRAME RELAY LINE -1 CAT5 � PLENUM CABLES. SECURITY STROBE J -BOX CABLE (BY OTHERS) , ■ ❑�~ III _ SECURITY PANEL J -BOX -MOUNT @ 92" AFF & 15" L_ n IF I il IL II �> �� OVER FROM ADJACENT DUPLEX. J -BOX WITH COVERPLATE FOR NOW PLAYING SERVER * DEDICATED 1/2" EMT CONDUIT TO SECURITY PANEL J -BOX LINE OF CEILING /I �.., I -� "STROBE LOCATION J -BOX J DEDICATED POWER CIRCUIT TO PANEL .1 — L r B g MI 8 0 (IF PRESENT) / / � ' I SAFE ARE - _ L u — Fp = H II I I II n r EACH CAMERA I MOTION DETECTOR DEDICATED POWER C CIRCUIT TO PANEL 1 RECEPTACLE FOR NOW PLAYING SERVER 3/4" EMT CONDUIT (BY OTHERS) (BY OTHERS) J BOX FOR DSL /FRAME RELAY LINE -MOUNT 92" AFF. MICROPHONE /SPEAKER FRONT DOOR CAMERA J -BOX (BY OTHERS) II DUPLEX FOR SECURITY PANEL -MOUNT @ 92" AFF. WHERE APPLICABLE SECURITY J -BOX J BOX FOR P05 TELEPHONE. POWER CIRCUIT TO PANEL — — QUADPLEX FOR SECURITY CAMERA POWER SUPPLIES -MOUNT 92" AFF. 8 – 1 I I II 11 MI RECEPTACLE— 4- SQUARE BOX FOR LAN. RECEPTACLE DEDICATED DUPLEX FOR POS. FOR SCALE RECEPTACLES FOR IL — — FOR GRINDER I 1 DUPLEX FOR SECURITY -MOUNT @ 48" AFF. r ° — 1 ---- DUPLEX OUTLET FOR MUSIC SYSTEM awri=1 8 i� POS STATION EXPEDITOR STATION P05 STATIO SCALES, CHECK VALIDATION & CASH POS STATION I I © J -BOX FOR SECURITY KEYPAD. WORKSTATION DEDICATED DUPLEX (ORANGE) PLUG I I I I T I P - - -- I I 4 - -7 — _DRAW_ERS E — l 7 - -- — 1 -- FI--- --I - II I , I II I �I— -- _ __ II II H ' IN ONLY ISOBAR HERE -MOUNT @ 42" AFF. „wool 1 0 SEA OTHER DETAILS I I I I 0 ' FOR ADDITIONAL REC'. II SAFE J BOX FOR POS TELEPHONE. � °o III- -7 1+ - I °O I \ II 0 \-- �- — 1I II 1I � Y b o oOI I Ba I $ 8 I I 8 d o o -4 SQUARE BOX FOR LAN. DEDICATED DUPLEX FOR POS. pri __J I I I L __ I I —J b III II I _� = ; -- � —I Ili 11 RECEPTACLES FOR SCALES, CHECK VALIDATION & CASH DRAWERS I -- WINDOW POS BEAN POS MAIN POS WITH SAFE DEDICATED CONDUIT TO SECURITY PANEL J- BOXY -- J -BOX LOCATED ADJACENT TO SAFE DEDICATED DUPLEX SQUARE BOX FOR QUAD RECEPTACLE MANAGER'S STATION 12" AFF. .J J -BOX FOR (2) TELEPHONE JACKS. _ � _ _ NOTES: 1) COORDINATE ALL J -BOX LOCATIONS WITH SECURITY VENDOR PRIOR TO ROUGH IN INCLUDING SECURITY PANEL, SAFE, KEYPAD, STROBE, FRONT DOOR CAMERA, MOTION DETECTOR, MICROPHONE /SPEAKER, AND CAMERA. 2) COORDINATE "SECURITY J -BOX" AND "SECURITY STROBE J-BOX" LOCATIONS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. 3) CONDUCTORS ARE NOT SHOWN. ■ OUTLET FOR SAFE (ORANGE) POWER CIRCUIT(S) TO PANEL • SEE E2.0 , LAN/POWER/PHONE/SECURITY SYSTEM DIAGRAM 0 MAIN BONDING JUMPER SERVICE DISCONNECT SWITCH 1200A PANEL - '1E' PANEL SWBD 451 E1 F (CONFIRM) - (OTHER TENANT SWITCHES -NOT OUTSIDE OF AVAILABLE FAULT CURRENT =16 874AMPS TO NEUTRAL BUS GROUND BUS BOND TO BLDG. STEEL PER CODE. BUILDING STEEL ; M O R PANEL BOARD i BOND TO METAL WATER PIPE. FED FROM PER SHELL ELECTRICAL PLANS 480/277V, 30,4w SHOWN) � POWER CHECK METER 200A/3P BREAKER (CONFIRM) ( �. BOND TO EQUIPMENT FOOTING ,� MAIN WATER SHUT -OFF VALVE $ a $ b $ c $ d A -32 Q /► STARUCKS SPACE 4#250KCMIL, W /GND AL. MC CABLE (CONFIRM) F &I ADDITIONAL RELAYS L.. — AS NEEDED. � — SIGNAGE - _ ..1 ASTRONOMIC TIMESWITCH, TORK *7200Z, SET TO TURN ON AT 500 AM AND OFF AT 1:00 AM (PER STARBUCKS DIRECTION) ON 24 HRS /DAY LOCK ON CIRCUIT LIGHTING DETAIL B CKT.- --b- CONDUCTORSiTYPNG ELECTRODE 5' -0" MAX PANEL 1 3 3 3 CONTROL ZONE SCHEDULE NOTES AHJ) GROUND ROD(S) -- -----4.- (IF ALLOWED BY NOTES: �� ii %• .\ , ,4 ,,a 200A FUSED 45KVA TRANSFORMER SPACE STARBUCKS 4$00 -- 208V/120V 30, NEMA TP -1 S WITCH AVAILABLE FAULT CURRENT - 11,541AMPS L. >� MAIN WATER SERVICE COPPER WATER LINE 4W �_ 45KVA TRANSFORMER UNDERGROUND. EXOTHERMIC WELD. REBAR SHALL POINT A MIN. Y2" DIA. AND 20 FT. IN LENGTH, ENCLOSED BY MIN. OF 2" OF CONCRETE. NEMA TP 21Q8V/120V 30, 4W GND PER CODE � 4 #1 CU., W/ GND. IN 1 -1/2 "C a - DISPLAY/ ACCENT $ b - WORKROOM c - FRONTBAR/ BACKBAR d - SALES AREA LIGH TING CONTROL INDICATES SWITCH DIAGRAM GND PER CODE _ _ 4 #250KCM 4#1 CU., W/ GND. IN 1 -1/2"C li 3}6 CU., rg �_ AL., W /GND 125A 3P 4 W /GND IN '� 3/4"C 3/4 C AL. IN 2 -1 /2 C 125A V / 3P MAIN 1. THIS DETAIL IS APPLICABLE WHEN STARBUCKS IS MODIFING AN EXISTING OR INSTALLING A NEW BUILDING SERVICE. IF MAIN BUILDING POWER SERVICE IS BY OTHERS, CONTRACTOR SHALL ENSURE GROUNDING SYSTEM INSTALLED BY OTHERS IS PER CODE. 2. GROUNDING ELECTRODE SYSTEM INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH LOCAL CODES AND /OR AUTHORITIES HAVING JURISDICTION. 3. ALL GROUNDING ELECTRODE CONDUCTORS AND BONDING JUMPERS TO BE SIZED PER CODE. E AIL GROUNDING D T 60A /3P ' 125 AM,�' „ 200 AM 125 AME „ PANEL B PANEL A 208V/30 PANEL H 208V/30 4$0V/30 SERVICE ONE --LINE DIAGRAM � SEELNDL0RD'SSCOPEOFWORKONSHEETE1.O 000NTROL 0 FILL ANNULAR SPACE W /UL LISTE t (TESTED PER ASTM E 119) FIRESTOP CAULKING WITH A RATING MATCHING THE WALL OR CEILING /FLOOR RATING (SEE ARCH. SHEETS FOR WALL/ CEILING /FLOG' RATING). RIGID STEEL SLEEVE INSIDE DIAMETER THAN PASSING THRU. 1" GREATER CONDUIT 0 b .....00C)76 INF Ni Ile k -'.--;:l SEE SCOPE OF WORK ON SHEET 44) NI.: k \ \ \ \ \�� tli: `��Z��� MATERIAL. CONDUIT WALL 6 RATED WALL OR CEILING /FLOOR - SEE ARCHITECTURAL DRAWINGS FOR RATING. PENTRATING OR CEILING CONDUIT MINERAL /WOOL BACKING RATED /FLOOR DETAIL — „ ���� I/ .,- .: =`¢ s �. ,.B. ',A - �� _Ya ° E � _ ® 60 � � ._.: - ' 3 , ti NTS EXPIRES ,f: A STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORA ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATU LA S (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. CONSULTANTS ALE ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739-6051 (425) 739-7362 AER123@AOL.COM REV DATE JC DESCRIPTION 0 0 L.L m Ce F- w Z W LOU 0 Uz 1^ O co co Co U W O CO CO CO Q Q J 0 D 0 PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE ELECTRICAL & LIGHTING DETAILS SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER E4.0