Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-083 - MICROSOFT - TENANT IMPROVEMENT
MICROSOFT 3433 S 120 PL D08 -083 Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Tenant: Name: MICROSOFT Address: 3433 S 120 PL , TUKWILA WA Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Phone: Contact Person: Name: KAROLINE MELROSE Address: 10202 FIFTH AVE NE SUITE 102 , SEATTLE WA 98125 Phone: 206 - 547 -1940 Contractor: Name: DAVIS SCHUELLER INC. Address: 20700 44 AV W , LYNNWOOD WA 98036 Phone: 206 775 -9400 Contractor License No: DAVISSI105PN doc: IBC -10/06 Cityillf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT * * continued on next page ** Permit Number: D08 -083 Issue Date: 03/27/2008 Permit Expires On: 09/23/2008 Expiration Date: 07/01/2008 DESCRIPTION OF WORK: MODIFY LOCATION OF WALLS & DOORS TO CREATE TENANT SUPPLY STORAGE, WORK AREA AND HALLWAY. MODIFY RESTROOM TO ADD (1) STALL WITH WATER CLOSET AND RELOCATE SHOWER. Value of Construction: $240,000.00 Fees Collected: $3,763.20 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: V -A Occupancy per IBC: 0008 D08 -083 Printed: 03 -27 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City ccOTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Print Name: doc: IBC -10/06 Permit Number: D08 -083 Issue Date: 03/27/2008 Permit Expires On: 09/23/2008 Date: 3 )-- D I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature, � p, Date: () This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -083 Printed: 03 -27 -2008 Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Tenant: MICROSOFT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 - 083 Status: ISSUED Applied Date: 02/13/2008 Issue Date: 03/27/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: doc: Cond -10/06 D08 -083 Printed: 03 -27 -2008 15: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 16: Maintain fire extinguisher coverage throughout. • S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 17: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and International Building Code. 18: Minimum widths of corridors shall be maintained in accordance with Chapter 10 of the International Building Code and the International Fire Code. 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 21: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 22: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 23: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 24: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 26: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 27: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) doc: Cond -10/06 D08 -083 Printed: 03 -27 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 30: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 31: In combustible construction, fire blocking and draftstopping shall be installed to cut off all concealed draft openings (both vertical and horizontal). (IBC 717.1) (IBC 717.2.2(a,b) 32: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 35: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 36: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 37: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 38: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 39: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** D08 -083 Printed: 03 -27 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: �� g �c Date: Print Name: doc: Cond -10/06 rp D08 - 083 Printed: 03 -27 -2008 SITE LOCATION CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Tenant Name: MISOGT Name: pfg4LINE 4/lErixoSe Mailing Address: /OOZ Zj fin) Are s//7/1 /o7, Company Name: TAP Company Name: AVA Building Permit No. 1)0 9 -0 8 3 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: /tZ3O4 - / a.Ui Site Address: ? S 0141.4 tiOni 17L TIIYVILA, WA 1 ,3161$ Suite Number: A/A Floor: / New Tenant: ❑ Yes off .. No Property Owners Name: / /kril/A770NAAL eieti1WAit EAST, GLG Mailing Address: /ZZDI TNYW/LA /NT�i - A/ATlost/4L $U/D / 4 PADA, SeAT7Zt yb /f City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 20&' 647 1140 77L&, VVA 915/ City �lnn State Zip E -Mail Address: / YD /I k h'1&kd (AJ. het Fax Number: /GVto" *47" Z /7i GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: k v VV ! 7; Mailing Address: /OZD?/ R AVE Ne cW /1 7 , tr rQ Tf) /2 ' City �^ State Zip Contact Person: ?7( 61.ANS - net/ Day Telephone: ZV - i47" /940 E -Mail Address: 40(1 d 9 kd W k /' 1 Fax Number: zaps- *47- eZ,2 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:Vlpplications\Forms- Applications On Line U-2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Page 1of6 BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 'Z4 9 000 /,, Existing Building Valuation: $ 4, 1S7, (P00 Scope of Work (please provide detailed information): 4101 �iU 4772 /.S D4 IVA-US 4 Ixois G l M A A d \ f r Bona � S •z'e4 ) W o , A & , AND • _IA.. 4 ■ I Ile _ 4 , oo/v X gg �GA�7z ‹ -• Will there be new rack storage? Yes ❑.. No PLANNING DIVISION: // /a Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Ai 16, Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: a . r - Will there be a change in use? Provide All Building Areas in Square Footage Below ❑ Yes Q: Apphcations\Potms- Apphcattons On LneV -2006 - Permit Application.doc Revised: 9 -2006 bh FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers g Automatic Fire Alarm ❑ None If yes, a separate permit and plan submittal will be required. "r° s ProVip Ulo . Compact: S1 Handicap: £)UST No If `yes ", explain: Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantiti.., and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per Type of Occupancy per IBC l Floor // OW sr 1, e.. �r /v L'/A N/A / IBC v -A g (Orrice) r Floor A N/a 3` Floor " N/A Floors thru /a —71. N Basement A N /^ / Accessory Structure' /, D Attached Garage / - Detached Garage .1 / A Attached Carport N /A i. Detached Carport k• iNi/ Covered Deck N/A Uncovered Deck N iN l A BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 'Z4 9 000 /,, Existing Building Valuation: $ 4, 1S7, (P00 Scope of Work (please provide detailed information): 4101 �iU 4772 /.S D4 IVA-US 4 Ixois G l M A A d \ f r Bona � S •z'e4 ) W o , A & , AND • _IA.. 4 ■ I Ile _ 4 , oo/v X gg �GA�7z ‹ -• Will there be new rack storage? Yes ❑.. No PLANNING DIVISION: // /a Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Ai 16, Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: a . r - Will there be a change in use? Provide All Building Areas in Square Footage Below ❑ Yes Q: Apphcations\Potms- Apphcattons On LneV -2006 - Permit Application.doc Revised: 9 -2006 bh FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers g Automatic Fire Alarm ❑ None If yes, a separate permit and plan submittal will be required. "r° s ProVip Ulo . Compact: S1 Handicap: £)UST No If `yes ", explain: Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantiti.., and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 W ER O' AUTHO' Z . D AGENT: Signature: l r t ; ► .�:� / . i�� Date: 4Z/1 Z /O& Print Name: / /kPd)L /N& M eizosE Day Telephone: IOU — rJ47 — lll 194 o Mailing Address: /DMZ RPM AYE Ale, S1iiTi 1.02, SeArn,e, 9012 s City State Zip Date Application Expires: E 13 _ og Date Application Accepted: 2 13-- 06 Q:'Applicetions\Fmms- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 M Staff Initials: ci ! O Page 6 of 6 Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Applicant: MICROSOFT Payee: KDW ARCHITECTS ACCOUNT ITEM LIST: Description rinr.- Raraint -11R PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 34359 60.00 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Receipt No.: R08 -01330 Payment Amount: $60.00 Initials: WER Payment Date: 04/24/2008 03:31 PM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000/345.830 60.00 Total: $60.00 Permit Number: D08 - 083 Status: ISSUED Applied Date: 02/13/2008 Issue Date: 03/27/2008 1581 04/24 9711 TOTAL 60.00 Printed. 04- 94- 9(1(1R Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Applicant: MICROSOFT Receipt No.: R08 - 00932 Initials: WER User ID: 1655 Payee: KDW ARCHITECTURE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://wwwci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 34138 2,282.50 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/386.904 RECEIPT Total: $2,282.50 Permit Number: D08 -083 Status: APPROVED Applied Date: 02/13/2008 Issue Date: Payment Amount: $2,282.50 Payment Date: 03/27/2008 10:05 AM Balance: $0.00 2,278.00 4.50 0479 )3 /2' 1719 TOTAL 2282.50 doc: Receiot -06 Printed: 03 -27 -2008 Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Applicant: MICROSOFT Receipt No.: R08 -00425 Initials: WER User ID: 1655 Payee: KDW ARCHITECTS a • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 33905 1,480.70 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 1,480.70 Total: $1,480.70 Permit Number: D08 -083 Status: PENDING Applied Date: 02/13/2008 Issue Date: Payment Amount: $1,480.70 Payment Date: 02/13/2008 03:21 PM Balance: $2,282.50 8553 02/13 9710 TOTAL 1480.70 doc: Receiot-06 Printed: 02 -13 -2008 Project: M,��las� -� Type of Inspection: r- ;AiQ e0. -Al Address: At Date Called: J Special Instructions: I( Date Wanted: a.m. R equester: Phone No: r� ?,4 (0 'S/ 20 00k - OU INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t -- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Ec t i Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: A Aote___ Inspeftor: ' 4 i Date: - 3 r J J G 1 ❑ $58.00 REINSPECTION FED REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: !Date: e !sJdT' *. ' ''"' :' " Q ike nmm. �,.. - COM M ENTS: C2 n 3r JkA1(1 .e j 'f pp/ i c-or r> tut pc/ � n v, Date Called: — 31,A.c.PJ /4 - 6- d / - akN iv d ( '.4) r " lA)" '` 7 7 1 - ze r .Sb —4 , 2 l / c V i 4,)-,1- Requester: (A-i - O ALP / e £ A ! (-` ) 7 p t J t (4 .n 0" j", A -6 -3i e 01- `tt LV : 1 ProjectA `Citas pi-- `. Ty of Inspe ion: } , et, Add�ress: C PL-- 3 ! y ) 3 J . / 7 T + f l.^ a Date Called: — Special Instructions: Date Wanted: , a•pi. 0 .' 3 0 - U� p.m. Requester: Phone No j( Sio — 7?2- dt-3. Approved per applicable codes. 0 o2 083 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 orrections required prior to approval. A IDate: / 4 r 4 (p� a ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Projecct Type o Inspec on: e /2i PZ Date Called: Special Instructions: Date W me a. Requester: Phone No• INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: Project: Type of Inspection: • I rlreA 44 ; II Address: 34 33 sa, 1 / 24 Date Called: Special Instructions: / Date Wanted: , - a.m- 5 - 3 O - dirEr p.m. Requester: Phone No: _ S to, 1 12 4, '1,06 l Oc* g3 INSPECTION RECORD Retain a copy with permit INSPECTION c. -• PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: /`.1J (1 ` GJ; (I Be_ S) Je Inspec ' or: Date:, j t.1 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. f Receipt No.: Date: ti Project: , i /u .S�T Type of Inspection: _�-%�4 Address: S X3.3S i ?d RL- Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: 0 72Z inQg - 4M INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: �4. ,/2.144-'4. ( /7/) 14 i/ / c_t c..�) ne C . i e." (J rov $58. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: z. �akl e.�, tmC iY�P''�f.t �¢"y �• L'"�d 4g tYl �", c3 COMMENTS: 0 % „V S - 1 ,A C.A f r,v E IAlt} - s(0LJfr rJ M� e, (c C ' cJ4( (NA. IA r �p 1U J - 01 Date Called: Cpl.._ A )--: - :)/) A4' b,c.e 4 /' vv? 0 A f -- A Ut t er ructions: (-,)r .A, ., St 6-e P1 lL Date Wanted: IN a A Project: 442/( Type of Inspection: �m /ry & A /2e) 01 Date Called: S peciia n ructions: Date Wanted: Requester: Phone No: c206-57 d - 7; , 2 INSPECTION NO. Approved per applicab cod INSPECTION RECORD ,,ll Retain a copy with permit U v1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Inspe Date 1 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: • • �..:a.m;...' -- -- - - s�.er .t - " r. 1 - " 5.:�- .sue... s.: Project: eti /3 ri-i Le,,. ;1 y a. Type of Inspection: 3ja., /F,'.t. FAQ...I Address: 3 5 1W v 'L . Suite #: Contact Person: c. rive- 5/7 0/4401 — Speaal Instructions: Phone No.: Needs Shift Inspection: _ Sprinklers: Are Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy .Jype: . 2 INSPECTION NUMBER 444 Andover Park East, Tukwila. Wa. 98188 206- 575 -4407 El / Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT COMMENTS: ti 4 51� :144tle", GAP p ... Word/Inspection Record Form.Doc 1/13/06 Corrections required prior to approval. 241 0.1 3 PERMIT NUMBERS Inspector $lv 5 Date: 61/7/o/ Hrs.: s $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: ''J - cum z Type of Inspection: Address: 3 3, iA9 Pc_ Suite #: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Approved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT - 0g.3' O - PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 1/13/06 F7 Corrections required prior to approval. COMMENTS: 0M1>te or Inc coo +afi• Inspecto &ILA 512 Date: 6- 6 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection: T.F.D. Form F.P. 113 Project: - Tut( G ►/t S bA @ MC A-I Type of Inspection: Fire Alarm: Address: 33 S S S , 12.0v" Rt_ Suite #: Contact Person: • x- . Cotatlkl2.6r iqt . Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 411 .044 «'F!c3:.F%i.L :t'P'+J:f�ris?5• rat+. .'".�.f�CCSv.;i52�iyt�'fk;: -6ux i 'r.•i'kf • 4 INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 COMMENTS: �tE.s ' '1 N 1 . • _ -r 4 41 ---- Approved per applicable codes. Inspector: (ALVA /9 I ?- - ( Date: $121 Joe $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit • CITY OF TUKWIILA FIRE DEPARTMENT 1/13/06 'PERMIT NUMBERS n Corrections required prior to approval. . rs. 2_ T.F.D. Form F.P. 113 J M\ May 28, 2008 Ms. Joan Hatchet KDW, P.S. 10202 Fifth Avenue NE Seattle, WA 98125 -7472 Project: Microsoft, Tuk 2 (East) 3433 South 120 Place Tukwila, WA 98168 MS Project: P11170 KDW Project: K -07 -14901 Subject: Wall Stud Heights Dear Ms. Hatchel: This office has been requested to review the steel stud sizes used in the construction of a partition wall at the noted project. It is our understanding that the wall is non - bearing and it is not anticipated to support any loads other than its own weight in the future. Based on the information provided and utilizing the lateral load of 5 psf which is the minimum load mandated by the 2006 edition of the International Building Code, the 6 " -18 gauge studs (600S125-43) spaced at 24" centers that have been installed meet the strength requirements for a height of 26' -0. It is important to note that at this height, the criteria of L /120 will yield a maximum anticipated deflection of approximately 2.6 ". Therefore, for serviceability reasons, we would recommend that the GWB be attached as required by the SSMA for composite wall construction and this attachment will bet this assembly very close to a L/240 condition (SSMA Manual, pages 12 and 13). Please feel free to contact our office should you have any questions regarding the contents of this letter or this project. Sincerely, JMN CONSULTING ENGINEERS, PLLC M. Nissen, S.E. cipal Consulting Engineers, PLLC 1319 Dexter Avenue N., Suite 295, Seattle, WA 98109 -3568 t. 206-281-0767 f. 206 -281 -0769 dog 4)S-3 01' A M 7 Z,k0. , •• FILE COPY Permit No REVISION NOB IL 8- 0 83 REVIEWED OR CODE COMPLIFANCE APPROVED APR - 3 2008 Of Tukwila B I I DWI IO RECEWED MAR 27 2008 PERMIT CENTER STI SERIES *00,0 STOPPER® STATIONS Standard and custom, ADA Compliant, low /high voltage switches These ADA Compliant, multi - purpose push- button switches cover a wide range of applications both indoors and outdoors. They're called Stopper Stations. They incorporate a unique, patented design that helps dramatically to stop accidental activation. A number of standard models are available or we can create custom units to meet your needs exactly. You have your choice of any of five universal colors identifying switch usage, wording and language. They work as great as they look Because of their superior, patented design combined with quality construction throughout, you can expect outstanding performance for years to come. In fact, many STI customers are surprised to find that all this quality is available at no increase in price. Plus, customers appreciate the option to protect the switches with STI protective covers that carry a lifetime guarantee against breakage in normal use. For indoor applications, you can order your Stopper Station with a pre -alarm cover to help stop malicious and accidental activation. Safety Technology International, Inc. 2306 Airport Road • Waterford, Michigan 48327 -1209 Phone: 248 - 673 -9898 • Fax: 248 - 673 -1246 Toll Free: 800 - 888 -4ST1 • E-mail: info @sti- usa.com Web: www.sti - usa.com 55-2004 55-2400 CUSTOM LABEL SS-2301 ADA Compliant EVACUATE S5- i204 5S-2107X SS -2403E • Unique, curved design helps protect against accidental activation. • 5VA flammability rating on backplate and spacer. • Station housing molded of super tough polycarbonate. • Your choice of colors —red, green, yellow, white or blue (red Key -to -Reset buttons "0" and "2" - Step 3 on page 4 - can only read "FIRE" PER UL Listing, SS -2000F and SS -2002F models). • UL Listed to U.S. and Canadian safety standards (excluding "6" the Momentary Touch Button as shown on page 4, step 3) • Raised standard or custom vinyl labeling. • Polycarbonate tested for -40 °F to 120 °F ( -40 °C to 49 °C). • Buttons with Mini Weather Stopper® cover are outdoor rated and listed by UL to NEMA 3R standards. • Wording in virtually any language. • Push buttons are ADA Compliant. • Lifetime guarantee against breakage of polycarbonate cover with normal use (one year on electronic components). • Stainless steel backplate. Safety Technology International (Europe) Ltd. Unit 3 Olton Wharf • Richmond Road • Olton Solihull • 892 7RN • England • Tel: 44 (0) 121 707 2999 Fax: 44 (0) 121 707 8999 • Freephone: 0800 085 1678 (UK only) E -mail: info @sti- europe.com • Web: www.sti- europe.com ERIES 2000 STOPPER® STATIONS Covers to protect your STI Stopper Station from damage or weather and to help stop malicious or accidental activation. Mini Stopper® II This smaller cousin of the famed Stopper° II helps stop false fire alarms and can protect your Stopper Station against damage indoors as well as malicious or accidental activation. It consists of a tamperproof, clear polycarbonate shield that fits easily over any STI Stopper Station model. When it is lifted to gain access to the Stopper Station, it sounds a piercing 105 dB warning horn. Legitimate activation is not affected. The protective cover is available with or without the optional horn. The virtually indestructible cover comes with a lifetime warranty in normal use. Custom labeling is available. Note: See separate spec sheet for complete cover details. UNIQUE BUTTON FEATURES EMERGENCYE%R'i 1 LIFT COVER -PUSH 8UTiOT - EXIT Mini Weather Stopper® This tough cover, without a built -in alarm, is used to protect any STI Stopper Station from damage or the weather in outdoor use or indoor harsh environments. It is a less costly choice where malicious or false activation is not a problem. STI Mini Weather Stopper is ideal for environments such as those on ocean going ships, oil rigs, beachfront condos, car washes or any area subjected to saltwater conditions. It is available in any of four colors for both flush and surface mount installations. Weather gaskets are included. Tested to NEMA 3R standards. Note: See separate spec sheet for complete cover details. IN CASE OF EMERGENCY I LIFT COVER-PUSH 80 rON LIFT HERE SS -2460E Models SS-2000F (FIRE) • Standard switch includes two N.O. contacts. Holds up to three sets of isolated contacts either N.O. or N.C. Models SS ° 00, SS 2 *01, SS 2" 03, SS - 2 *04 • Interchangeable or replaceable N.O. or N.C., SPST gold - plated contact blocks rated for 3 amps @ 600 VAC or 1 amp @ 250 VDC (no backbox available). • Standard switch includes one N.O. and one N.C. contact. Holds up to three sets of isolated contacts. Model SS ° 02, SS 2 ° 05 • 2 sets of Form "C" contacts rated at 7 amp @ 125/250 VAC. • Includes color coordinated surface mount backbox. Model SS 2"06 (Not UL Listed) • One N.O. contact, SPST, 24 VAC /DC 0.2A • Includes color matching backbox with fasteners. Bopper Stopper® Now you can protect your indoor Stopper Station from vandalism or accidental activation with the STI Bopper Stopper. Both this protective cover and its hinges are molded of tough polycarbonate material so you know it will take hard knocks in stride. To help prevent corrosion, the hinge spring is formed from stainless steel. The combination of Stopper Station with a Bopper Stopper protective cover is for indoor use only. *Note: No labeling can be placed on the Bopper Stopper cover. See separate spec sheet for complete cover details. SS -2010F Other Covers Available (All come in Red, Blue, Green or Yellow) STI -6600 STI -6605 STI -6525 STI-6535 STI -6540 STI -6545 STI -6515 STI -6518 Mini Stopper II with horn - flush mount Mini Stopper II with horn and spacer Mini Weather Stopper - flush mount Mini Weather Stopper with spacer - clear Mini Stopper II without horn - flush mount Mini Stopper II without horn, with spacer Stopper° Seal Tamper resistant accessory for Mini Stopper Bopper Stopper with spring loaded hinge - clear Please note that it is mandated by UI. that your Stopper Station be protected with an STI Mini Weather Stopper when used outdoors. Model SS - 2 ° 07 • Illuminated button rated at 125 VAC /250 VAC 10 amps (no backbox available). 28 volt incandescent lamp included. Model SS - 2 "08 Switch rating 7 amp. (resistive) 240 VAC and has a timer range: 2 - 60 seconds (± 15 %). • Temperature range of button 15 °F to 120° F ( -9 °C to +49 °C). • Timer life of over 1,000,000 operations. • Includes color matching backbox with fasteners. • Pneumatic operation timer which opens or closes circuit after time delay. No electricity to operate. • Ideal for security applications. • Two sets of isolated contacts, 1 N.O. and 1 N.C. *NOTE: Second digit designates color (see page 4). STI SERIES 2000 STOPPER® STATIONS Dimension and Technical Information It has been tested and approved or listed by (all except "6" button): • Underwriter Laboratories No. 57255 • Canadian Underwriter Laboratories No. 57255 • ADA Compliant STI RECOMMENDS THE USE OF THIS SPACER FOR SWITCH CLEARANCE ON STANDARD SINGLE GANG BOXES. SEE NOTE. PUSH-TO-ACTIVATE AND - KEY-TO RESET #0 SPACER SUB -102722 .69 In. (17mm) EXISTING STANDARD SINGLE GANG BOX" BACKPLATE ASSEMBLY 19030 KEY ONLY PUSH - TO-ACTIVATE AND TURN - TO-RESET #1 MOMENTARY MUSHROOM #4 SVA FLAMMABILITY RATING ON BACKPLATE AND SPACER 'NOTE: USE SPACER ON #0, #1, #3 AND #4 KEY -TO- ACTIVATE #3 KEY -TO -RESET AND MOMENTARY BUTTON #2 #5 MOMENTARY TOUCH BUTTON #6 ILLUMINATED BUTTON #7 Switch /Button Activation Type Refer to chart on page 4 — PNEUMATIC ADJUSTABLE TIMER BUTTON #8 3.25 in.(82mm) PRODUCT DIMENSIONS 1.62 in. 1.56 in. (41mm) (40mm) r 4 , TO PROVIDE ADEQUATE CLEARANCE FOR CONTACTS, INSTALLATION MAY REQUIRE: SUB-102722 SPACER "A a 0 Z Momentary Touch Button, Number 6, is not UL or cUL Listed. "A" - Contact Depth SS -2"00 2.25" 55-2 "01 2.25" 55-2 "02 1.25" S5 -2 "03 2.25" 55 -2 "04 2.25" 5S -2 "05 1.25" 55-2 "06 0" 5S -2 "07 1.5" 55 -2 "08 1.4" NOTE: Spacer depth is 1.56" Project Info Project Address 3433 South 120th Place Date 2/12/2008 Tukwila, WA 98168 For Building Department Use Applicant Name: !Caroline Melrose Applicant Address: 10202 5th Ave NE, Suite 102, Seattle, WA 98125 Applicant Phone: 206 -547 -1940 Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form FILE C PIT Permit No. ® .. ` 'y i n. r f'" ° l �, ~y`. t'.�< i _ �' i . ^� ( i S +,,? cisS 1 Do8- 083 CODE C OMPII ►K WA 21 2008 Revised July 2007 FEB. 13 2006 CENTER Project Info Project Address 3433 South 120th Place Date 2/12/2008 Tukwila, WA 98168 For Building Department Use Rm 174 Applicant Name: Karoline Melrose ApplicantAddress: 10202 5th Ave NE, Suite 102, Seattle, WA 98125 Applicant Phone: 206 - 547 -1940 Project Description Rm 171 ❑ Plans Included requirements. ❑ New Building ❑ Addition J Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option O Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting , Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft Area in ft Allowed x Area Rm 174 Office 1.00 368.0 368.0 Rm 171 Corridor 0.80 414.0 331.2 Rm 173 Office 1.00 955.0 955.0 Rm 177 Restroom 0.80 243.0 194.4 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1848.6 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Rm 174 2x4 Recessed Flourescent, (3) F32T8 Lamps, 4 93.0 372.0 Electronic Low TED Ballast Rm 171 2x4 Recessed Flourescent, (3) F32T8 Lamps, 2 93.0 186.0 Electronic Low TED Ballast Rm 171 Recessed Cmpt Flourescent Down Light, (1) 26W TRT Lamp, 3 27.0 81.0 Electronic Low TED Ballast Rm 171 20' Track Light, (8) 136711/FL Ledra Track Display Lamr 8 3.0 24.0 Rm 171 Exit Sign, LED 2 1.6 3.1 Rm 173 2x4 Recessed Flourescent, (3) F32T8 Lamps, 10 93.0 930.0 Electronic Low TED Ballast Rm 177 Recessed Cmpt Flourescent Down Light, (1) 26W TRT Lamp, 6 27.0 162.0 Electronic Low TED Ballast Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1758.1 Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. Use' LPA (W /sf) Use' LPA (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /bars' 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hall' 4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 TABLE 15 -1 Unit Lightinst Power Allowance (LPA Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Project Info Proj Addres 3433 South 120th Place Date 2/12/2008 Tukwila, WA 98168 For Building Department Use Name: T(aroliae Melrose Appl. Name 10202 5th Ave NE, Suite 102, Seattle, WA 98125 Appl. Phone 206- 547 -1940 Project Description ❑Plans Included requirements. ❑ New Addition ✓ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option O Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/W ❑ Controlled by motion Sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ✓ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT Tradable Maximum Allowed Lighting Wattase Tradable Proposed Lighting Wattage otal Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage roposed Watts may not exceed Allowed Watts for Category Total Allowed Watts Revised July 2007 Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Total Proposed Watts Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 1 0.15 W/ft Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater plaza areas Special feature areas 0.2W /ft Stairways 1.0 W/ft Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W/ft Outdoor Sales Open areas (including vehicle sales lots) 0.5 W/ft Street frontage for vehicle sales lots in addition to "open area" allowance 20 W/linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the s pecific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 W/ft for each illuminated wall or surface or 5.0W/linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities W/ft2 1.25 W/ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W/ft f uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restaurants 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry Exterior Lighting Summary (Oa ck) LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Adjusted Lighting Power Allowances (Interior) ** From Table 15 -1 based on exceptions listed in footnotes Revised July 2007 Project Address 1 3433 South 120th Place !Date 2/12/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception** Adjusted LPA Watts per ft2 Lighting, Motor, and Transforrner Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 3433 South 120th Place !Date 2/12/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) I Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local controlaccess Schedule with type, indicate locations A - E - 02 n.a. 1513.2 Area controls Maximum limit per switch n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls A - E - 02 1513.5 Exterior shut -off Schedule with type and features, indicate location n. a. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n. a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 IMax. watts (Indicate watts for each exit sign IA - E - 02 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) n.a. I 1540 (Transformers 'Indicate size and efficiency I I 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 1 f February 26, 2008 Karoline Melrose 10202 Fifth Avenue NE Seattle, WA 98125 • City of Tukwila Department of Community Development Jack Pace, Director RE: CORRECTION LETTER #1 Development Application Number D08 -083 Microsoft — 3433 South 120 Place Dear Ms. Melrose, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen, at 206 - 433 -4163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Brenda Holt Permit Coordinator encl xc: File No. D08 -083 P:\Pennit Center \Correction Letters\2008\D08 -083 Correction Ltr !lI.DOC wer • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Building Division Review Memo Date: February 26, 2008 Project Name: Microsoft Permit #: D08 -083 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The proposed shower compartment does not meet accessible clear space requirements. Section 304.4 specifies unless otherwise specified, doors shall be permitted into turning spaces. However 603.2.3 #2, doors shall not swing into the clear floor space or clearance for any fixture. Exception 2) of 603.2.3 specifies where the room is for individual use and a clear floor space complying with 305.3 is provided within the room beyond the arc of the door swing. The shower clear floor space shall be a minimum 48" x 36" (608.2.1). Please revise plan to show compliance for accessible clearances and where sufficient room is allowed beyond the arc of the door swing. (2003 ANSI 304.4, 603.3.3 & 608.2) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D08 -083 DATE: 03 -27 -08 PROJECT NAME: MICROSOFT SITE ADDRESS: 3433 S 120 PL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued DEPARTMENTS: Public Works PN k— /) Complete Comments: TUES/THURS RO TING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • • PLAN REV %ROUT SLIP r 6H rug 4 °� Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: n w(,4. 3 , 31,0 Planning Division H Permit Coordinator DUE DATE: 04-01-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DATE: DATE: Ei ►i i L1 DUE DATE: 04 -29 -08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: HERMIT COORD COPY • PLAN REVIEW/ROUTING SUP ACTIVITY NUMBER: D08 -083 DATE: 03 -06 -08 PROJECT NAME: MICROSOFT SITE ADDRESS: 3433 S 120 PL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: , B i :�n � ivision Nj Public Works Complete Ff Comments: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 n n DATE: DATE: Planning Division Permit Coordinator No further Review Required Not Approved (attach comments) DUE DATE: 03-11-08 Not Applicable ❑ n DUE DATE: 04-08-08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -083 DATE: 02 -13 -08 PROJECT NAME: MICROSOFT SITE ADDRESS: 3433 S 120 PL X Original Plan Submittal Response to Correction Letter # Revision # After Permit Issued Response to Incomplete Letter # DEPART ENTS: i47491› Bui g +IVisio� P Complete Comments: TUES/THURS ROUTING: Please Route Approved Notation: Works ti - 1406' Documents/routing slip.doc 2 -28 -02 PER aT COORD COPY PLAN REVIEW /ROUTING SLIP [-7/ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: tilz m t' 2 -zl Fire Prevention 1� Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required Approved with Conditions n ❑ Permit Coordinator DUE DATE: 02 -14 -08 Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: ❑ No further Review Required DATE: DATE: 2 441 PI Wing Divisio Not Applicable n t.� DUE DATE: 03 -13 -08 Not Approved (attach comments) Permit Center Use Only / CORRECTION LETTER MAILED: r Departments issued corrections: Bldg d Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS ISSUED DATE STAFF INITIALS 1 , - 7- - A O Summary of Revision: W& k -P oS (,�,�- Summary of Revision: /4 C c,,,, ieckker- Received by: .._3 o , (___k,,, , REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: . Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: M1[ vo SITE ADDRESS: Z1-k33 S 1)0 j REVISION LOG PERMIT NO to 0 e3 ORIGINAL ISSUE DATE: 3 - 0 $ (please print) (please print) (please print) (please print) (please print) O S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us i REVISION SUBMITTAL i Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: - / 2 I / ° v Plan Check/Permit Number: D 0 8 - O 83 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # (gl Revision # after Permit is Issued Di--t. ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: M1CJ2c.5 aF'( Project Address: 3 4 33 - So D 1,-4 t-z. 6 P LC-rL Contact Person: Metsce/ Phone Number: ZDCv - S47 - Summary of Revision: - ,° �`��� L Received at the City of Tukwila Permit Center by: ®Entered in Permits Plus on 3 ) 7- 0 e \applications\foims- applications on line\revision submittal Created: 8 -13 -2004 Revised: H Ar-r 'rto C . t -l_ . 1-47 -, e- - Ca L- c s 13ra y -z. 'R - t 5e. -s -►s1 al t , -t,S V 3 -- (2,0 AA le 4-► t� t-� Sheet Number(s): .A- — - O I. "Cloud" or highlight all areas of revision including date of revision R Steven M. Mullet, Mayor Steve Lancaster, Director 3 cXtTO RECEIVED crrY TUOF mmut MAR 2 7 2008 •' tAIIIT cENTER P v f R]EVISION SUBMITTAL i Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cI.tukwia.wa.vs ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # L after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: MICROSOFT Project Address: 3433 South 120 Place Contact Person: Karoline Melrose Summary of Revision: A c ose C 2- ,pu:pi - 04. i `( •11. vJ` '5' FLoca SCACc CoC)R .2. S -o I..L - re2 a. fltM� kr-% CP—XF—v.s J — ta Sheet Number(s): - M - O 1 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: f Entered in Permits Plus on 0 ✓bat `in ` \applicationslfor ms- applications on iinelrevisian submittal Created 8 -13 -2004 Revised: • Plan Check/Permit Number: D08 -083 �tECF c g ' 4,1A MAR 0 6 20 NEAMITCEIm, Eh Phone Number: ZDC& - 54 l°t�c7 Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 •— Shower, per head 2 2 — 7„ 4 Dishwasher 2 2 -- •7 Drinking fountain (each head) 1 .5 . ai 7. Hose bibb (interior) 2.5 2.5 •— — Clotheswasher or laundry tub 4 2 — — -- Sink, bar or lavatory 2 1 d-- e ?j Sink, Clinic flushing 8 8 -- — — Sink, kitchen 3 2 — / 7L Sink, other (service) 3 1.5 -- 'L 3 Sink, wash fountain, circle spray 4 3 — — -- Urinal, flush valve, 1 GPF 5 2 — -- — Urinal, flush valve, >1 GPF 6 2 — Z 4 Urinal, waterless 0 0 •— — Water closet, tank or valve, 1.6 GPF 6 3 — "7 .Z I Water closet, tank or valve, >1.6 GPF 8 4 -- — •— King County Department of Natural Resources and Parks Wastewater Treatment Division Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type IZd 4 ' PLicr- Property Street Address Cit S ate lP INT'I 6s- 'ft-na - S T 1 LLG O wner'a Name Subdivision Name Subdiv. # 8-093 Lot # Block # Building Name //v (,Ai . j gi-91 44-1 (if applicable) ( 2 ) 277 - 26 (6pA&J Litei) Owner's Phone Number (with Area Code) (A) 3/i SG 2 47 (oLaivT) Property Contact Phone Number (with Area Code) Owner's Mailing Address 'Zip/ 7111 VV IL11 thrit-P-N4TThty &i. ,LVi A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 Total Fixture Units 'I.D RCE Property Tax ID # I O Z C 1 11)UI Party to be Billed (if different from owner) City or Sewer District W.LV V1 E. Date of Connection `-- Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑ Yes .t� Was building on Sanitary Sewer? El Yes O No !.I //6- Was Sewer connected before 2/ /90? ID Yes ❑ No /■/ JA. Sewer disconnect date: d A . Type of building demolished? /U f Request to apply demolition credit to multiple buildings? ❑ Yes ❑ NA/ A. B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Ai/A Estimated Wastewater Discharge: Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ d 187 C. Total Residential Customer Equivalents: (add A & B) A B a RCE White - woo County Yellow - Local Sewer Aaencv Pink - Sewer Customer Gallons /days RCE FEB 13 2008 Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of orrected data for etermination of a revised capacity charge. Signature of Owner /Representative d./0 /'Ggtita Date i Z /J V C o Print Name of Owner /Representative k ,,A ga iNE tIf L - OSE (V , PS) 1058 (Rev. 9/07) License Information License DAVISSI105PN Licensee Name DAVIS SCHUELLER INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601273797 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 20700 44TH AVE W STE 280 Address 2 City LYNNWOOD County SNOHOMISH State WA Zip 98036 Phone 4257759400 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/15/1990 Expiration Date 7/1/2008 Suspend Date Separation Date Parent Company Previous License SEACRMI104DE Next License SILVECI988QO Associated License Business Owner Information Name Role Effective Date Expiration Date DAVIS, BILL E PRESIDENT 01/15/1990 SCHUELLER, DANETTE SECRETARY 01/15/1990 DAVIS, BARBARA D TREASURER 01/15/1990 SCHUELLER, KENNETH E VICE PRESIDENT 01/15/1990 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Company Bond Account Effective Expiration • Cancel I Impaired Bond Received Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= DAVISSI105PN 03/27/2008 ACTIVE ACTIVE 955 SF B OCC. 10 0.L. PARTS & ALLOCATION MI • MX Mil ME Ili MI MI ME MI MI Ell Mil lin • lin In Ell ME BR Mil MI EXISTING REQUIRED FLOOR SP RE PANEL, ' LEAR CE ALLOCATION TOTAL (18) SHELVES 30 X 48 X 7' HIGH CONTRACTOR TO PROVIDE OWN TOILET FACILITIES DURING DAYTIME HOURS. ACONTRACTOR TO VERIFY THAT ALL WALLS ARE FULL HEIGHT TO SLAB AROUND PERIMETER OF STORAGE ROOM. GENERAL NOTES 0 PARTITION KEY NOTES: ARCHITECTURAL 1. NEW WALL FROM FLOOR SLAB TO SLAB RELOCATED DOUBLE DOORS, HARDWARE AND SECURITY DRAWINGS. THE DOUBLE CARD READER DOORS PROVIDE 1 SUCCESSFUL CARD SWIPE ON THE EXIT 2 LIFTING THE COVER AND PRESSING THE CARD READERS. COORDINATE LOCATIONS OF DEVISES WITH EXITING FROM THE SECURED SIDE OF THE DOOR IN FOUR WAYS. READER EMERGENCY DOOR RELEASE (ERD) WHICH INTERRUPTS THE POWER LOCALLY TO THE DOOR AND ALLOWS EXIT 3 FIRE ALARM ACTIVATION 4 CATASTROPHIC POWER LOSS TO THE SECURITY SYSTEM PROVIDE NEW 1—HOUR H.M. FRAME AND DOOR. SEE 14/A— M-01. PROVIDE WALL STOPS. PROVIDE MAGNETIC HOLD OPEN LINKED TO THE FIRE ALARM SYSTEM THAT WILL CLOSE DOORS WHEN FIRE ALARM IS ACTIVATED. 4\ 4. EXISTING HOLLOW METAL FRAME AND P—LAM DOOR TO BE REPLACED WITH 1—HOUR H.M. DOOR. NEW CARD READER ON BOTH SIDES OF DOOR WITH EMERGENCY EXIT BUTTON AS SHOWN. PROGRAMMING IS AS FOLLOWS: COORDINATE WITH SECURITY DRAWINGS 1 SUCCESSFUL CARD SWIPE ON THE EXIT READER 2 LIFTING THE COVER AND PRESSING THE EMERGENCY DOOR RELEASE (ERD) WHICH INTERRUPTS THE POWER LOCALLY TO THE DOOR AND ALLOWS EXIT 3 FIRE ALARM ACTIVATION 4 CATASTROPHIC POWER LOSS TO THE SECURITY SYSTEM P—LAM PASS—THRU COUNTER —30" X 48" WIDE TEMPERED SLIDING WINDOW WITH LOCKING ROLLING FIRE DOOR ON CORRIDOR SIDE OF 1—HOUR WALL. SEE DETAIL 13/A—M-01. 14. PROVIDE (2) 4—PLEX RECEPTACLES , &15. PROVIDE WHIP POWERED AND COM TO POWERED PANELS EACH SIDE OF THE ROOM. EACH WORKSTATION TO HAVE (1) 4—FLEX RECEPTACLE AND (4) DATA, (PHONES IP). TUKWILA 2 BUILDING 3433 SOUTH 120TH PL TUKWILA WA 98168 2-13-08 REVISION Revisions No. Date Description 01-10-08 BID DOCS 02-12-08 PERMIT SUBMITTAL 03-20-08 REVISION 1111211M111112111MBINIMMOMM Sheet litie PARTITION PLAN PERMIT DRAWINGS DATE: 02/12/08 r UP CFCT) PARTIAL FLOOR PLAN SCALE: 1 /4" = 1 ' — SF:48 (. 8 ' OFFICE I 174 I 368 SF B OCC 4 O.L. 0 NORTH OFFICE I 176 rI- 0" BREAK 0 CORRIDOR 0 178 I L__ WOMENS I 179 I 10 ALTERNATE SCOPE, SEE 6/A—M-01 CONFERENCE ROOM 1 I 180 ( ) L H () GRIND DOWN ADHESIVE FROM 0 ILE AND CARPET. CL FLOOR, E-1. 8. PROVIDE NEW CARPET, TRANSITION AT DOORS AS REQUIRED. 9. PROVIDE NEW ENTRY MAT. 10. PATCH AND REPAIR ALL WALLS DAMAGED FROM DEMO WORK. PAINT ALL WALLS P-1, SEE FINISH SCHEDULE BELOW. 11 PROVIDE RED PAINTED STRIP ON FLOOR IN FRONT OF FIRE PANEL. 4" WIDE BAND @45' ANGLE 4" APART WITH 4" WIDE BAND AROUND PERIMETER. 12. PROVIDE E NEW FIRE EXTINGUISHER CABINET IN ROOM 173. 13. RELOCATED EXISTING WINDOWS, DOOR AND CARD READER. ELECTRICAL COMMUNICATIONS 16. PROVIDE (1) STANDARD DUPLEX. 17. FIRE STROBES — RELOCATE AS REQUIRED BY CODE. NOTE LOCATION OF SHELVING WHEN PLACING WALL UNITS. /\8. 42" PLASMA SCREEN AND MOUNTING BRACKET, O.F.C.I. G.C. TO PROVIDE BLOCKING FOR MOUNTING AND POWER/ DATA AND AV OUTLET IN WALL FOR SCREEN. INSTALL AT 60" A.F.F. TO CENTER OF SCREEN, CENTER IN ALCOVE. INTENT IS TO LEAVE WOOD PANELING IN PLACE AND ACCESS FROM GWB WALL BEHIND. WORK TO BE COORDINATED WITH OWNER. WALL BOX — CHIEF 510 ACCESSORY BOX AND MTR SERIES TILT MOUNT FOR 125 POUND MONITOR. VERFY OWNER FURNISHED MONITOR. P-1 CPT-1 CPT-2 CPT-3 FINISH SCHEDULE BENJAMIN MOORE 923, FRENCH VANILLA A I PREP CONCRETE AND APPLY VALSPAR No changes shall ben-7G7le to the scope of work without sion. prior approvai of Tukwila E3uilding Divi NOTE: Revisions will require a new plan submittal and may include additional plan revial..r fees. BENTLY PRINCE STREET CARPET, URBAN TRIBE COLLECTION, CIVIC GENERATION BROADLOOM, COLOR: CREATIVE CLASS 882015. PACIFIC MAT & COMM FLOORING, CHEVRON. CUT TO FIT EXISTING RECESSED AREA, COLOR: BENTLEY PRINCE STREET CARPET TILES, URBAN TRIBE COLLECTION, FAMILY RITUAL, COLOR: CREATIVE CLASS 882015. INSTALL QUARTER—TURNED. VALSPAR, MORRITEX INDUSTRIAL COATING 8 MILS. COLOR: GRAY; OR APPROVED EQUAL. NEVAMAR ET5001T CLOSE ENCOUNTERS RUBBER BASE, 4" TOPSET, COLOR: CREAM TO MATCH EXISTING. WALL TYPES t' 1 11EIBEINCEND4 NEW PARTIAL HEIGHT WALL TO SUSPENDED CEILING, SEE 17/A—M-01. NEW FULL HEIGHT WALL TO EXISTING STRUCTURE ABOVE, SEE 11/A—M-01. NEW PARTIAL HEIGHT TO GWB CEILING, SEE 12/A—M —01. FILE COPY Permit No.i22titt Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or oninance. Receipt of approved Field Copy and cotxons is aclumwledged: By - 4 — Le_LC_■Q Date: 4 City of Tukwila BUILDING DIVISION REVISION Nal_ bo8-083 CHARCOAL. SEPARATE PERMIT 1 I REQUIRED FOR: re Mechanical arElectrical lipturnbing Iii. Gas Piping I City of Tukwila , BUILDING DIVISION REC hAt 27 2008 PERMIT CENTER 7 I Mic Ltn Team Design JOAN HATCH EL Drawn BD Checked DOUGLAS A. DIEL Date 02/06/08 Internal Project No. K-:07-14901 M.S. Project No. P. 11170 KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw. net 3912 Registration c-t REGISTERED ARCHITECT DOUGLAS A. DIE. STATE OF WASHINGTON Key Plan Bar Code Sheet Title AD-'O1 AA A O B C AREA OF WORK ., MIC , _ .,._ 2 3433 SOUTH 120TH PL ® ® i T����� WA a �� q�� O . ,__ ( (_, �- . i 1 REGE7VIN C _ E) C -�� J C 0 I® .J I EXIT ' \ _F_) / _ – ` EXIT 1 1) I – o o EXIT DOCK SEC • ' . O i n % , � 1 I I ��� EXIT EXIT % `J u D5 111 I SSS/// r - 1 — — D( -1 J V I INSTAL .. -. 174 _ _ . . (1 R 3 I1 it =;�,a �- l / ! Y F 1 CORRIDOR 149 : = '4N : r i f � . Y �' V 1 1 1 J l Q+� - SE CURRY' I I ■ L� 175 M I 9 �. � -- - l ENCLOSURE 103 - - I - - — _-- —._. w -: L II 9 EXIT D4 OPS// OPS// , CU STOMER WORK AREA . I CIYAER WORK AREA _ — 155 ' - y 110 WI 146 I • H DAT - EC & TEL DAT , 53 '� ® D I �� i ____L-L. 118 I i. il Er / / /- / / / C 1 D3 11091 I I i d ddd _ i ! i ! Mp F F14 DATA E 3 CORRDROR ,. III m NI l (., Revisions EECI / � ► ft 11 MAINTENANCE STORAGE 11171 I to j 'ICON-1 URN tl €NF 1! RM `i ROOM 1 182 O FFICE J � v � OFFICE 1 168 I OFFICE OFFICE 1170 I OFFICE 171 J OFFICE I ! �9�� . / IT fah RPU ENCLOSURE I l l N0. Dote Description nom a N II = 169 �' ' i < d — 190 01-10-08 BID DOCS �� \ X 1 i - -( \ 02 -12 -08 PERMIT SUBMITTAL ® 106 MAINTENANCE SHOP f -- TELCO A MDF L1371 I -- --X 1-1/G ° D 4') - 1 — FUEL TANKS R I I - i 1 D1 1071 1 1201 • _ ° tl EXIT �/ E X I\ - EQUIPMENT E I CO-LO 1 CO-LO 2 � I ® 4 _ _- ® CO-L0 6 '� V OFFICE 3 166 - � I 11391 I X ^ ■ 1 1431 144L0 Wd ENCLOSURE za 1 _ S J = : - ...._. __..._.... ■ DR 106 I ee AP FACT � I a ONiRO EC 1 a a � T C — : 1 L CORRIDOR I CORRIDOR J '�� I 1 1 I I I I I X 1 X - -- C --- I YI ,� 1166 EC I, I - - -- S JI /� / �+ I ! / KD V V , PS 10202 5th Ave N E Seattle WA 98125 206,547.1940 p X , i � J OPS TECH WORK AREA 1 1241 -- -- X ,-- � PUMP ELECTRICAL ROOM M3 L 1311 ' cRmcAL EQUIPMENT ' ., "' r STORAGE I 1 - - - - -- 7 1T 125 I � DPS /CUS �'' maw' TELCO C ' DATA ,58 • 159 AI I I 1 11551 1,56 I ARCHITECTURE ENGINEERING 206.547.8212 f V1/VVW,kdw.net — -� DC • - „ . . - I I — -- - -- -. —,�C PLANT e DO °NT �— –}.6 SWGR --- ELECTRICAL i QOM M2 1301 \ \/ —F 1 �– - - 135A 111- I - --- I h 1458 — 153 '� , \ .___ -�1 \ a 15981 �_ , � Y EC , � � _ - ( t �� _._.._... X J � � 11261 EC 161 - ® X X ' EC 754 PUMP c - .- -. - ELECTRICAL ROOM M7 1 1291 X X EC , 53 ROOM E h — ` / EC 141 r ELEC EMERG iffl — . — 1 EC 1132 1 EC — EC gal CO -LO 5 3 ELECTRICAL ROOM MO 133 1152 1 } - ) EXIT �.. _ ' 1 p " .. ^ . - r: : SPRINK 1,5,1 PUMP ROOM Ind ___) T UKW ILA I E AST -F _ _ : _�_ "` :� , EXIT :, Design Team Des; n 9 JOAN HATCHEL SCALE: N.T.S. �I NORTH Drawn VCINTY MAP NOT TO SCALE CODE INFORMATION ABBREVIATONS SYMBOLS B D OCCUPANCY INFORMATION Checked DOUGLAS A. DIEL SEATTLE . . CODES FOR 2006 INTERNATIONAL BUILDING CODE THIS PROJECT: 2006 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL FIRE CODE 2006 UNIFORM PLUMBING CODE 2005 NATIONAL ELECTRIC CODE 2006 IBC REQUIREMENTS FOR BARRIE FREE ACCESS, CH 1 1, APPENDIX E, SUPPLEMENTARY ACCESSIBILITY ALL CODES AS ADOPTED AND AMENDED BY THE STATE O F WASHINGTON. CODES FOR EXIST. BL DG.: 1997 UB 1997 UFC 1997 UMC 1 994 WA. STATE ENERGY CODE 1994 WA. STATE BARRIER FREE CODE © AT LAV. LAVATORY CENTERLINE L.H. LEFT HAND # NUMBER LIN LINOLEUM EP SQUARE FEET X' DEGREE(S) MAX. MAXIMUM MECH MECHANICAL MTL. M ACOUS. ACOUSTICAL MEZZ. MEZZANINE AC.T. ACOUSTICAL TILE MFR. MANUFACTURE(R) ADJ. ADJACENT MIN. MINIMUM ADJUS. ADJUSTABLE MISC. MISCELLANEOUS A.F.F. ABOVE FINISH FLOOR MTD. MOUNTED ALT. ALTERNATE A PPROX APPROXIMATE N. NORTH N.I.C. NOT I N CONTRACT ARCH. ARCHITECT NO. NUMBER BD. BOARD NOM. NOMINAL BET. BETWEEN N.T.S. NOT TO SCALE BLK BLOCK BUILDING O OVERALL BLKG. BLOCKING 0.C ON CENTER BDT. BOTTOM O.D. OUTSIDE DIAMETER O.F.O.I. OWNER FURNISHED / CAB. CABINET OWNER INSTALLED CER. CERAMIC OH. OVERHEAD CIRC. CIRCLE OPNG. OPENING CLG. CEILING OPP. OPPOSITE CR. CLEARANCE) P. BD. PARTICLE BOARD COL. COLUMN CONST. CONSTRUCTION PLAM PLASTIC LAMINATE CONT. CONTINUOUS PLWD. PLYWOOD CONTR. CONTRACTOR PNL. PANEL CORR. CORRIDOR PR. PAIR CPT. CARPET PTN. PARTITION CTR. CENTER RAD. RADIUS DEMO. DEMOLITION REF. REFERENCE DIAM. DIAMETER REQ. REQUIRED DIM- DIMENSION REV. REVISION DN. DOWN R.H. RIGHT HAND DR DOOR R.O. ROUGH OPENING DWG. DRAWING S. SOUTH . EACH S.C. SOLID CORE E. ELEVATION SCH. SCHEDULE ELEV. ELEVATOR SECT. SECTION SIM. SIMILAR EQ. EQUAL SPEC. SPECIFICATION EQUIP. EQUIPMENT EXH. EXHAUST SQ. SQUARE STAINLESS STEEL EXT. EXTERIOR STD. STANDARD STL. STEEL F.E. FIRE EXTINGUISHER STOR. STORAGE F.E.C. FIRE EXTINGUISHER CABINET STRUCT. STRUCTURE FIN. FINISH(ED) FLR. FLOOR SUSP. SUSPENDED FT. FOOT /FEET TEL. TELEPHONE GA. GAGE TEM P. TEMPERED G.B. GRAB BAR THK. THICKNESS GEN. GENERAL TYP. TYPICAL GL. GLASS /GLAZING G.W.B. GYPSUM WALL BOARD UNFIN- UNFINISHED GYP. GYPSUM U.N.O. UNLESS NOTED H.C. HOLLOW CORE OTHERWISE HD. HEAD HDR. HEADER VCT VINYL COMPOSITE TILE VEN . VENEER HDWR. HARDWARE VERT- VERTIGAL HORIZ. HOR ZON ALTAL VEST. VESTIBULE HR. HOUR VFY. VERIFY HT. HEIGHT V.W.C. VINYL WALL COVERING H.V.A.C. HEATING VENTILATING W. WEST / WIDE & AIR CONDITIONING W/ WITH r Plumbing INSUL. INSULATION INT. INTERIOR W/o WITHOUT WSCT. WAINSCOT JAN. JANITOR WT_ WEIGHT JT. JOINT 4 A -M-02 USE OF ALL ROOMS IS 'OFFICE' UNLESS NOTED OTHERWISE Date 02/06/08 •. - gO —. DETAIL / PLAN REFERENCE Internal Project No. EXISTING OCCUPANCY: B OFFICE ( ) K -07 -14901 EWOTT BAY -�__ .... B (UPS ROOM QUALIFYING UNDER IFC 608) M.S. Project No. F -1 (DATA ROOMS — RAISED FLOOR AREA) P. 11170 A -M -02 SECTION REFERENCE 4 H-3 H 3 GENERATOR ROOM) ) RE VIEWED FOR ���� ���P Registration ��� APPROVED BOEING FIELD M qR A - M -02) r ELEVATION REFERENCE AREA OF NEW WORK: 3912 REGISTERED q[ 9r BOEING NORTH REFERENCE MAR 008 AREA: 2037 S.F. I �. I . OCCUPANCY B OFFICE �y ® ( ) B : I ICI DIVISION ARCHITECT � � Do �iGLAS A. DIEL STATE OF WASHINGTON LtcCESS RD. 2051 ROOM NUMBER PROJECT SRE �� y , a � w gM � s © R/• H l VE DOOR NUMBER n OCCUPANT LOAD FACTOR: 100 :: __ ••- -_ -_ OCCUPANT LOAD: 21 Key Plan 413) cap SECURITY CARD READER DESCRIPTION OF WORK P5 WALL TYPE CONSTRUCTION i .... 24 KEY NOTE REFERENCE ® DATUM POINT -- BREAKUNE SYMBOL A REVISION REFERENCE ® SPRINKLER HEAD REMOVE WALLS AND DOORS AND PROVIDE SUPPLY STORAGE AREA. REVISE MEN'S RESTROOM TO ADD (1) TOILET AND RELOCATE SHOWER. FILE COPY Permit No 5 -00 r .....___ -- Bar Code Plan review Bppmvalis stbjectto errors afd anistions. A ! ^++ � *!+� .�...........r.... _ �. ►1fj�. NORTH SEA -TAG INT L AIRPORT A T I ®I I �1 F 1. VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING WORK. INFORMATION FOUND IN THESE DOCUMENTS DO NOT NECESSARILY REFLECT EXISTING CONDITIONS, AND SHOULD NOT BE HELD ACCOUNTABLE FOR THEIR CONTENT OR ANY IMPACT ON PROJECT MISCOORDINATION. FOR AREAS OF CONCERN FIELD VERIFICATION IS NECESSARY. 2. ALL EXISTING WORK DAMAGED BY WORK IN THIS CONTRACT AND SCHEDULED TO REMAIN SHALL BE REPAIRED TO MATCH ADJACENT FINISHES AND IS SUBJECT TO REVIEW AND APPROVAL BY ARCHITECT AND OWNER 3. COORDINATE ALL WORK WITH OTHER TRADES. PROVIDE FOR NECESSARY NEW OPENINGS FOR WORK ITEMS PASSING THROUGH WALLS, FLOORS AND CEILINGS AS REQUIRED. PATCH AND REPAIR AS REQUIRED. MAINTAIN ALL RATED SYSTEMS. 4. WORKING HOURS ARE TO BE COORDINATED WITH CLIENT. 5. THE INTENT OF THE DRAWINGS IS TO SHOW GENERAL SCOPE AND INTENT OF THE WORK. METHODS AND MATERIALS NOT EXPLICITLY IMPLIED ARE INTENDED TO BE BUILDER DESIGNED. 6. QUALITY OF MATERIALS AS SPECIFIED SHALL BE CONSIDERED MINIMUM AND ANY CHANGE SHALL BE OF DEMONSTRATED EQUAL OR BETTER QUALITY UNLESS SPECIFICALLY RELEASED BY OWNER AND APPROVED BY THE BUILDING DEPARTMENT. MATERIALS NOT SPECIFIED SHALL BE OF A HIGH QUALITY INTENDED FOR COMMERCIAL USE. MATERIALS ARE TO BE INSTALLED IN A PROFESSIONAL MANNER TO THE HIGHEST INDUSTRY STANDARDS, ALL PARTS TO BE COMPLETE AND OPERATIONAL. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES TO AVOID INTERFERENCE BETWEEN DIVISIONS OF THE WORK. WHERE INSTALLATION AND /OR CONNECTION OF EQUIPMENT IS NOT SPECIFIED AND WHERE SUCH CONNECTION AND /OR INSTALLATION IS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM, THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR SUCH CONNECTION AND /OR INSTALLATION. a MEASUREMENTS. DR NOT FY ARCHITECT IF DIiSCREPANCIIES DIMENSIONS ON THE DRAWING AND ACTUAL HELD 9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY PRECAUTIONS TO PROTECT OWNERS FACILITIES FROM DUST, DEBRIS AND WATER DAMAGE DUE TO WORK DONE IN THIS CONTRACT. PROVIDE TEMPORARY DUST AND MOISTURE PROTECTION WHETHER OR NOT INDICATED ON PLAN. 10. PROVIDE FIRE CAULK AND DAMPERS TO MAINTAIN RATED SYSTEMS AT ALL PENETRATIONS. 11. MICROSOFT CORPORATION HAS FIRST SALVAGE RIGHTS TO ALL STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL AND LANDSCAPE ITEMS NOT BEING UTILIZED IN THIS SCOPE OF WORK. VERIFY SALVAGE DESIRES PRIOR TO DISPOSAL. PARCEL NO.: 1023049069 CONSTR. TYPE: TYPE V —A FULLY SPRINKLERED ZONING: MIC /H (MANUFACTURING INDUSTRIAL CENTER /HEAVY) SEISMIC ZONE: 5 BUILDING HEIGHT: 1 STORY SQUARE FOOTAGES: 1 5,01 0 S.F. . [I F.E. FIRE EXTINGUISHER CABINET o S.P. STAND PIPE -�... - __ �-. ��_ �� ._.�____• ...�,.,....�,...�.++ra.� �wra�+ilT�B vio l of any � code r� PROJECT T TEAM of apprwedF •� Copy 0 EXIT LIGHT PROJECT MANAGER (D) DEMOLISH STEVE THOMAS -, (E) EXISTING (N) NEW JONES, LANG La SALLE Sheet Title MICROSOFT CORPORATION City of BUILDING C V E R S H E E T ARCHITECT (R) RELOCATED DOUG DIEL KDW ARCHITECT ENGINEERING 206- 547 -1940 1 REVISIONS RECEIVED CONTRACTOR No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal ? � review and ma Y include additional plan n rev vie e w fees ! FEB 13 2008 PERMIT CENTEFI 0 0 8 .. 0 9 3 .. -a- m SEPARATE PERMIT SEPARATE REQUIRED FOR: s Mechanical !� iElectricai aCi Gas Piping City of Tukwila �BiI DIPIG ©IVISIQN INDEX DRAWINGS A - 1 COVER SHEET DATE: 02/12/08 A -1 .1 SITE PLAN A— C---01 DEMOLITION PLAN Sheet Title A —D -01 PARTITION PLAN A —E--01 DEMOLITION REFLECTED CEILING PLAN A „„ 1 A —E -02 REFLECTED CEILING PLAN A —F -01 FURNITURE PLAN A —M -01 ENLARGED PLAN AND DETAILS BU HNC 5 564,666 S.F. OCCUPANCY F -FR SPR \KLERED PARKING 1/1000 =188 440.1' 83.7' 4i 14 H �L21 C C ER - Wdth Wdth1 .PULP 57.411QN ._ SWITCH & a.AFu N89 219.99' • • —4— • 511 . 1` 5TH L. _au L2 4 T H S r R F F T EXISTING BUILDING EXISTING BUILDING = 05'43'03" R= 1265.90' L= 126,.32' u, 589'1642 "E 224.42' J ( i ' U, A ram 3 ■ ■ 1 1, P I I 1 181 --I 11 1 1111 I —1 1 I I111111>'ill 3333 S. 120TH PL. .3311 S. 120TH PL. pn Wpl 111111 , �E>tIS1e RUINING —Ir� InI CB J 1 1 BUILDING 2 107,489 S.F. OCCUPANCY S PARKING 1 /1000=108 V -N ;PRINKLERED CHAIN 1.1ro„CE N89 50"W 300.00' X el SITE PLAN FPSP1U/ SCALE: 1" = 100' - SF:1200 0 50' 100' 200' BUILDING 3 161 ,445 S.F. OCCUPANCY F PARKING 1/1000 =161 V -N SPRINKLERED n - 1171111 BLDG. #5 SWITCH GEAR (5)FT5PVLU ON WTu C NORTH METRO TRANSI T BASF c 3411 S. 120TH PL. PP +_�frT -PH S- TR T c 1111111��� n7541j Jl. 3 BUILDING 1 98,564 S.F. OCCUPANCY F PARKING 1/1000 =99 V —N SPRINKLEPEr EXISTING BUILDING s � w ❑ 11 11 1 1 II EXISTING BUILDING EXIST BLDG. ( R) EXISTING BUILDING EXISTING BUILDING 1 EXISTING BUILDING qv METRO TRANSIT BASE S REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 1 2008 CriyOf Dn. g ...' RECEIVED FEB 13 2008 PERMIT CENTER TUKWI LA 2 BUILDING 3433 SOUTH 120TH PL TUKWILA, WA 98168 No. Date Description _ 01 -10 -08 BID DOCS 02 -12 -08 PERMIT SUBMITTAL ARCHITECTURE ENGINEERING Design JOAN HATCHEL Drawn BD Checked Date DOUGLAS A. DIEL 02/06/08 Revisions Design Team Internal Project No. K -07 -14901 M.S. Project No. P. 11170 3912 KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Registration REGISTERED ARCHITECT DOUGLAS A. DIEL STATE OF WASHINGTON key Plan Bar Code Sheet Title SITE PLAN PERMIT DRAWINGS DATE: 02/12/08 Sheet Title A -1. CORRIDOR RESTROOM CONFERENCE ROOM 1 Q DEMOLITION KEY NOTES: 1. REMOVE EXISTING CASEWORK, SALVAGE GLASS, STORE AS DIRECTED BY CLIENT. 2. DEMOLISH EXISTING DOORS, SALVAGE (1) PAIR OF DOUBLE DOORS FOR RELOCATION AND MOVE (1) DOOR TO STORAGE AS DIRECTED BY OWNER. DEMO WALL AROUND DOORS AND CASEWORK. 3. DEMO WALL AND WINDOWS. SALVAGE WINDOWS FOR RELOCATION, SEE A —D -01 FOR NEW LOCATION. 4. DEMO WALL FOR NEW PASS —THRU WINDOW AND COUNTER OR DOOR, SEE A —D -01. 5. DEMO TILE FLOOR MATERIAL AND CARPET INSIDE NEW SUPPLY ROOM 173, HALLWAY AND OFFICE AREA. 6. EXISTING FIRE ALARM PANEL. LEAVE ACCESSIBLE AT ALL TIMES DURING CONSTRUCTION. 7. DEMO CARPET AND PREP FOR NEW CARPET TILE. 8. EXISTING CARD READERS TO BE RELOCATED. 9. EXISTING SYSTEMS FURNITURE TO BE REMOVED BY JLL. ALTERNATE SCOPE OF WORK: 1. DEMOLISH EXISTING SHOWER, CASEWORK AND DOOR, SALVAGE FOR RELOCATION. SEE NEW WORK PLAN. DEMO SOFFIT ABOVE LOCKERS AND WALL FOR NEW SHOWER DOOR LOCATION. DEMOLISHED WALLS City Of Tukwila B . IL® JIVISI N RECEIVE FEB 13 2008 PERMIT CENTS. TUKWILA 2 BUILDING 3433 SOUTH 120TH PL TUKWILA, WA 98168 Design Team Design JOAN HATCH EL Drawn BD Checked DOUGLAS A. DIEL 02/06/08 Internal Project No. K-07 -14901 M.S. Project No. hey Plan KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Registration REGISTERED ARCHITECT DOUGLAS A. DIEL STATE OF WASHINGTON Bar Code IMERIBMISMOMIEMMINfini Sheet Title DEMOLITION PLAN PERMIT DRAWINGS DATE: 02/12108 Sheet Title i CORRIDOR 1 150 SCALE: 1/4" = 1' -- SF:43 0 11 24 8 w -I DEMOLITION PLAN ll 174 I NORTH T . K� 171 7 E) K EQ. SECURITY CHECK —IN I 173 I LOUNGE I 176 I L K I I \ cr, rr� i r L r K r L I- CARPET L I 4 E 0 BREAK R M L_ P I _ RESTROOM 177 r SEE A —M -01 1 Revisions No. Date Description 01 -10 -08 BID DOCS 02- 12 ---08 PERMIT SUBMITTAL IL — Ft UP 1 - 0 1 8'—O" 17 — M — O ii NI ` EQ. 4 // C P1C=-3 3 2'-3 " PARTS & ALLOCATION 173 I 955 SF B OCC. 10 O.L. PARTIAL FLOOR PLAN SCALE: 1/4" = 1' - SF:48 0 1 2 4 8 ' OFFICE 174 368 SF B OCC 4 O.L. fl HALLWAY 171 0 4'-0" 13'-7" NORTH 11 —M-0 1E1 MEI ME MI ▪ 111 I= ▪ 111 I= ME 3 OFFICE I 176 I 1E1 ES El =1 EXISTING FIRE PANEL,.. REQUIRED CLEAR FLOOR SPACE I 01 Co F— =I ES EIS 1E1 1111 1E1 Ell =I 1=1 1E1 PARTS TOTAL 14 SHELVES 24x48x10' HIGH UNDER SEPARATE PERMIT ALLOCATION TOTAL (6) SHELVES 42" X 8' X 10' HIGH UNDER SEPARATE PERMIT ES 1M El El EN Nap 11111 BREAK 9t 5 II ETh--■ ESTROOM 177 C) CORRIDOR 178 - • RESTROOM 179 1 O'—O" LTERNATE SCOPE, SEE 6/A—M-01 CONFERENCE ROOM 1 I 180 I () GENERAL NOTES CONTRACTOR TO PROVIDE OWN TOILET FACILITIES DURING DAYTIME HOURS. PARTITION KEY NOTES: ARCHITECTURAL 1. NEW WALL FROM FLOOR SLAB TO SLAB ABOVE. 2. RELOCATED DOUBLE DOORS, HARDWARE AND CARD READERS. VERIFY EXISTING HARDWARE AND CARD READER CONTACTS. PROVIDE FAIL SAFE INSTUTITIONAL HARDWARE AND NEW CARD READER ON BOTH SIDES OF DOOR WITH EMERGENCY EXIT BUTTON AS SHOWN. 2 3. S P T R O O P V S ID . E NEW 1—HOUR H.M. FRAME AND DOOR. SEE 14/A—M-01. PROVIDE HOLDING MECHANICAL FAIL—CLOSED ELECTROMAGNETIC DEVICE, INTERLOCK WITH SMOKE DETECTION EQUIPMENT. PROVIDE WALL 2 4. EXISTING HOLLOW METAL FRAME AND P—LAM DOOR TO BE REPLACED WITH 1—HOUR H.M. DOOR. FAIL SAFE INSTUTITIONAL HARDWARE AND NEW CARD READER ON BOTH SIDES OF DOOR WITH EMERGENCY EXIT BUTTON AS SHOWN. 5. NOT USED. 6. P—LAM PASS—THRU COUNTER —30" X 48" WIDE TEMPERED SLIDING WINDOW WITH LOCKING ROLLING FIRE DOOR ON CORRIDOR SIDE OF 1—HOUR WALL. SEE DETAIL 13/A—M—01. 7. GRIND DOWN ADHESIVE FROM FLOOR TILE AND CARPET. CLEAN AND PREP CONCRETE AND APPLY VALSPAR FLOOR, E-1. 8. PROVIDE NEW CARPET, TRANSITION AT DOORS AS REQUIRED. 9. PROVIDE NEW ENTRY MAT. 10. PATCH AND REPAIR ALL WALLS DAMAGED FROM DEMO WORK. PAINT ALL WALLS P-1, SEE FINISH SCHEDULE BELOW. 11. PROVIDE RED PAINTED STRIP ON FLOOR IN FRONT OF FIRE PANEL. 4" WIDE BAND (4 ANGLE 4" APART WITH 4" WIDE BAND AROUND PERIMETER. 12. PROVIDE NEW FIRE EXTINGUISHER CABINET IN ROOM 173. 13. RELOCATED EXISTING WINDOWS, DOOR AND CARD READER. ELECTRICAL/COMMUNICATIONS 14. PROVIDE (2) 4—PLEX RECEPTACLES AT 36" A.F.F. 15. PROVIDE (1) 4—PLEX RECEPTACLE AND (4) DATA, (PHONES IP). 16. PROVIDE (1) STANDARD DUPLEX. 17. FIRE STROBES — RELOCATE AS REQUIRED BY CODE. NOTE LOCATION OF SHELVING WHEN UNITS. 18. 42" PLASMA SCREEN AND MOUNTING BRACKET, O.F.C.I. G.C. TO PROVIDE BLOCKING FOR POWER/ DATA AND AV OUTLET IN WALL FOR SCREEN. INSTALL AT 60" A.F.F. TO CENTER CENTER IN ALCOVE. INTENT IS TO LEAVE WOOD PANELING IN PLACE AND ACCESS FROM WORK TO BE COORDINATED WITH OWNER. WALL BOX — CHIEF 510 ACCESSORY BOX AND MTR SERIES TILT MOUNT FOR 125 POUND OWNER FURNISHED MONITOR. Fl \IISH SCHEDULE PLACING WALL MOUNTING AND OF SCREEN, GWB WALL BEHIND. MONITOR. VERFY P-1 BENJAMIN MOORE 923, FRENCH VANILLA CPT-1 BENTLY PRINCE STREET CARPET, URBAN TRIBE COLLECTION, CIVIC GENERATION BROADLOOM, COLOR: CREATIVE CLASS 882015. CPT-2 PACIFIC MAT & COMM FLOORING, CHEVRON. CUT TO FIT EXISTING RECESSED AREA, COLOR: CHARCOAL CPT-3 BENTLEY PRINCE STREET CARPET TILES, URBAN TRIBE COLLECTION, FAMILY RITUAL, COLOR: CREATIVE CLASS 882015. INSTALL QUARTER—TURNED. VALSPAR, MORRITEX INDUSTRIAL COATING 8 MILS. COLOR: GRAY; OR APPROVED EQUAL. NEVAMAR ET5001T CLOSE ENCOUNTERS RUBBER BASE, 4" TOPSET, COLOR: CREAM TO MATCH EXISTING. WALL t / / / ‘till:111:1113111311t PES NEW PARTIAL HEIGHT WALL TO SUSPENDED CEILING, SEE 17/A—M-01. NEW FULL HEIGHT WALL TO EXISTING STRUCTURE ABOVE, SEE 11/A—M-01. NEW PARTIAL HEIGHT TO GWB CEILING, SEE 12/A—M—01. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 1 2008 City Of Tukwila BUILDIN t1IVED FEB 13 2008 PERMIT CENTER 1. TUKWILA 2 UILDING 3433 SOUTH 120TH PL TUKWILA, WA 98168 Revisions Description No Dote 01-10-08 BID DOCS 02-12-08 PERMIT SUBMITTAL 2-13-08 REVISION ARCHITECTURE ENGINEERING Design Drawn BD Date 0 2/0 6/0 8 Internal Project No. M.S. Project No. P. 11170 KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Design Team JOAN HATCH EL Checked DOUGLAS A. DJEL K—OT-14901 Registration (_ 3912 REGISTERED ARCHITECT D UGLAS A. DIEL STATE OF WASHINGTON Key Plan Bar Code Sheet Title PARTITION PLAN PERMIT DRAWINGS DATE: 02/12/08 Sheet Title kma D Ea- 01 1 U W I— SCALE: 1 /4" = 1' - SF:48 I � 0 1 24' 8' 1_—h +- 0 I— I SUSPENDED CEILING i © 10' -0" A.F.F. DEMOLITION CEILING PLAN NORTH O LOUNGE 1 176 — ,._.__— h M1��� I � I � r L J. 4 -I - IL 4- 4 -1 -4 SUSPENDED EILING © 1 p' -6" lk.F.F. I------ I. - - - -- ----- { - - - - --f _BREAK_ ROOF 175 1 J T. L (4) 0 ti GWB (g 12' -0" A.F.F. GWB , � D ESTROOM 177 0 10' -O" A.F.F 0 9' -0" A.F.F. 0 0 II I � � r CORRIDOR 1 178 �L Z II II HI- II II II II II II 0 0 0 RESTROOM I 179 I tt - I II II II II II II I I I I II + - -- II II II II — — - i 4 - -- II II � �L — H — u 0 0 1T 7 0 0 CONFERENCE ROOM I 1 180 0 0 I I I I 11--I I F— DENOLTIOI\ REFLECTED CEILING P __AN KEY NOTES 1. DEMO EXISTING GWB CEILING AND SUSPENDED CEILING ' 12' -0" A.F.F. 2. DEMO SUSPENDED CEILING IN NEW SUPPLY ROOM 173. CEILING TO BE RAISED TO 14' -0" A.F.F. SALVAGE LIGHT FIXTURES FOR RE -USE IN RELOCATED GRID. 3. EXISTING SECURITY CAMERAS TO REMAIN AT CEILING AT ALL TIMES. PROVIDE TEMPORARY MOUNTING FOR CAMERAS TO BE OPERATIONAL AT ALL TIMES. - SIEV SCE CODE COMPLIA APPROVED MAR 21 2008 Oty Of Tuk ila s Iii. RECEWED FEB 132008 PERMIT CENTS& idigialfflaMENNABIENNEIMMON TUKWILA BUILDING 3433 SOUTH 120TH PL TUKWILA, WA 98168 Revisions No. Date Description 01 -10 -08 BID DOCS 02 -12 -08 PERMIT SUBMITTAL KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Design JOAN HATCH EL Drown BD Checked DOUGLAS A. DIEL Date 02/06/08 Internal Project No. K -07 -14901 M.S. Project No. P. 11170 Design Team Registration 3912 REGISTERED ARCHITECT DO GLAS A. DIEL STATE OF WASHINGTON Key Plan Bar Code Sheet Title DEMOLITION REFLECTED CEILING PLAN PERMIT DRAWINGS DATE: 02/12/08 Sheet Title A-EO1 LU SCALE: 1/4" = 1' - SF:48 8 ' Lii SUSPENDED CEILING @ 1C-0" A.F.F. oN OFFICE I 1 74 I HALLWAY REFLECTED CEILING PLAN 1 - PA'IS & ALLOCATION 173 SUSPENDED CEILING @ 15'-0" NORTH (1) EQ. A.F.F. LOUNGE I 176 TY 0 N EQ. Dl I 177 0 GWB @ 12'—O" A.F.F. ESTROOM GWB @ 1O'—O" A.F.F 0 GWB @ 9'—O" A.F.F. 0 n I I I I I I I I I I I I _ " I I I I I I I I I I 0 0 C 1 CORRIDOR 178 I I n 0 0 RESTROOM I 179 n 17— L E I I 0 0 0 n fr H H H I II II 1 I H H H I I I I H. = I I I I 14 LI 14 = I I I I It = I I I I = cD CO n 0 0 Ii U CONFERENCE ROOM I 1 180 —r 0 C T REFLECTED CEILING PLAN GENERAL NOTES 1. HVAC TO BE DESIGN BUILD AND ALL PERMIT TO BE PROVIDED BY CONTRACTOR 2. PER WASHINGTON STATE ENERGY CODE, CHAPTER 11, SECTION 1 1 32.3, THE EXISTING LIGHTING WATTAGE SHALL BE MAINTAINED OR REDUCED. REFLECTED CEILING P_AN KEY N OTES 1. INSTALL CEILING GRID IN ROOM 173. PROVIDE NEW SWITCH IN ROOM. INSTALL EXISTING 2X4 LIGHT FIXTURES AT NEW LOCATIONS SHOWN. 2. PROVIDE ALTERNATE PRICING FOR TRACK LIGHTING. TRACK LIGHTING SHALL BE PROVIDED WITH CONTROL SWITCH. 3. PROVIDE NEW 6" RECESSED CAN FIXTURE. 4. EXTEND EXISTING 9'-0" SOFFIT TO EAST WALL OF RESTROOM. PAINT TO MATCH EXISTING. 5. RELOCATE EXIT SIGNS TO NEW DOOR LOCATIONS. 6. PROVIDE NEW OR RELOCATE EXIST SWITCH TO NEW WALL. FIXTURE LEGEND N = NEW FIXURE vv 7 SECOND LOOK 4, 2X4 ACCOUSTICAL CEILING TILE 2X4 FLUORESCENT FIXTURE, RELOCATE EXISTING BRUCK TRACK LIGHT FIXTURE — MOUNT TRACK AT 7'-6" AFF 1 LEDRA TRACK RUN @ 20' WITH (8) FIXTURES (4) 136006MC LEDRA TRACK 6' (6) 136304 POWER FEED LEDRA TRACK CENTER MOD 6/136304 TO MAKE 3 JUMPERS (1) 136304 POWER FEED LEDRA TRACK CENTER (1) 70420 DC TRANSFORMER FOR LEDRA TRACK 14 FIXTURES (8) 136711/FL LEDRA TRACK DISPLAY WHITE 45" LENS (16) 136350 PICTURE HOOK LEDRA 0 6" RECESSED CAN, FLUORESCENT FIXTURE, MATCH EXISTING EXIT LIGHT, RELOCATE OR MATCH EXISTING, 1.57 WATTS PER FIXTURE INDEPENDENT REVIEWED FOR CODE COMPLIANCE APPROVED MAR 21 20138 !WING DIVISIQN RFCrh.q:' FEB 13 ZOO6 PERivilT GENT TUKWILA 2 BUILDING 3433 SOUTH 120TH PL TUKWILA, WA 98168 No. Date 01-10-08 BID DOCS 02-12-08 PERMIT SUBMITTAL ARCHITECTURE ENGINEERING Design Drawn Checked Date Design Team JOAN HATCH EL BD DOUGLAS A. DIEL 02/06/08 Internal Project No. K-07-14901 M.S. Project No. P. 11170 Revisions Description KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206,547.8212 f www.kdw.net Registration 3912 REGISTERED ARCHITECT D&JGLAS A. DIEL STATE OF WASHINGTON Key Plan Bar Code BOMIESSIESIBISMEMISMININN Sheet Title REFLECTED CEILING PLAN PERMIT DRAWINGS DATE: 02/12/08 Sheet Title AissEms,02 4•b.. kr! F.E.C. PARTIAL FLOOR PLAN PARTS & ALLOCATION 173 9 5 SF B OCC. 10 O.L. NORTH LOUNGE PARTS TOTAL 14 SHELVES 24x48x10' HIGH UNDER SEPARATE PERMIT ALLOCATION TOTAL (6) SHELVES 42" X 8' X 10' HIGH UNDER SEPARATE PERMIT ESTROOM CORRIDOR RESTROOM CONFERENCE FURNITURE PAN KEY NOTES PROVIDE THE FOLLOWING FURNITURE: 1. LAB BENCH 36 X 72 X 36" HIGH WITH SHELVES AND STOOL 2. (1) WORKSURFACE 30 X 48 (1) MOBILE PEDESTAL (1) TASK CHAIR 3. (14) SHELVES 24 X 48 X 10'-0" HIGH, EASY UP MEDIUM DUTY WITH WOOD SHELVES. 54" APART. INSTALLER TO PROVIDE REQUIRED PERMITS FOR INSTALLATION. 4. (6) SHELVES 42 X 8'-0" X 10'-0" HIGH, EASY UP HEAVY DUTY. SHELVES PLACED 54" APART. INSTALLER TO PROVIDE REQUIRED PERMITS FOR INSTALLATION. 5. PROVIDE WIP FOR BASEFEED CONNECTION TO POWERED PANELS. PROVIDE (1) 4—PLEX RECEPTACLE AND (4) DATA, (PHONES IP) AT EACH WORKSTATION. 6. PROVIDE (8) HERMAN MILLER 4X6 WORKSTATIONS, (16) HERMAN MILLER A02 PANELS 48"W X 67"H, (24) HERMAN MILLER A02 PANELS 24"W X 67"H, (8) HERMAN MILLER A02 CORNER WORKSURFACES, (8) HERMAN MILLER A02 WORKSURFACES, 24" X (8) HERMAN MILLER A02 OPEN SHELVES 24" (8) HERMAN MILLER A02 TASK LIGHTS, 24" WIDE (8) HERMAN MILLER MOBILE PEDS (8) TASK CHAIRS ALL PANELS POWERED WITH PANEL HUNG COMPONENTS. POWERED POWERD 48" X 48" 24" SHELVES PLACED fl VIEWED F37 CODE COMPLIANCE APPROVED 1 MAR 2 1 2006 Design Drawn BD Checked JOAN HATCH EL DOUGLAS A. DIEL 02/06/08 M.S. Project No. P. 11170 Design Team Internal Project No. K-07-14901 Registration REGISTERED ARCHITECT et 9 DO GLAS A. DIEL STATE OF WASHINGTON Key Plan Bar Code Sheet Title FURNITURE PLAN PERMIT DRAWINGS DATE: 02/12/08 Sheet Title TUKWILA BUILDING 3433 SOUTH 120TH PL TUKWILA, WA 98168 Revisions No. Dote Description 01 —1 0-08 BID DOCS 02-12-08 PERMIT SUBMITTAL ARCHITECTURE ENG INEERING KM, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547:8212 f www.kdw.net ® ALTERNATE SCOPE OF WORK: A. NEW WATERCLOSET AND PARTITION TO MATCH EXISTING. PROVIDE TILE FLOOR AND TILE WALLS TO MATCH EXISTING TILES. B. DEMO WALL FOR NEW DOOR. RELOCATE EXISTING GLASS DOOR AT SHOWER ROOM. C. NEW WALL WITH GWB LID. GWB SOFFIT OVER LOCKERS TO MATCH EXISTING CONDITION. SEE DETAIL 12/A –M -01. D. PROVIDE NEW PREFAB SHOWER STALL TO MATCH EXISTING ADA STALL. E. RELOCATE EXISTING CASEWORK, LOCKERS, BENCH AND STORAGE CABINET. F. NEW FLOOR TILE TO MATCH EXISTING 8X8 TILE AND TILE WALLS TO MATCH EXISTING WHITE TILE WITH ACCENT. G. NEW FLOOR DRAIN FOR SHOWER AND PLUMBING FOR SHOWER CONTROLS. SLAB CUT AND TIE INTO EXISTING DRAIN. RELOCATE OR MATCH EXISTING CONTROLS WITH NEW. H. PAINT WALLS TO MATCH STANDARD COLOR ABOVE TILE AND AT NEW WALLS. I. PROVIDE NEW ACCESSORIES, BOBRICK 301 & TOILET PAPER DISPENSER AND SHELF B2840. J. INSTALL RELOCATED LIGHT AND FAN FROM EXISTING RESTROOM. K. INFILL TILE AT DEMO SHOWER AREA AND AS REQUIRED FOR NEW SHOWER ROOM DRAIN. PROVIDE 2X2 AND 8X8 TILE TO MATCH ADJACENT FLOOR TILE_ L. PROVIDE NEW 4X4 WALL TILE TO MATCH EXISTING. EXISTING FINISHES: FLOOR TILE: DAL TILE DCO2, ALMOND, 8X8 2X2 TWO TONE ACCENT TILES WALL TILE: DAL TILE, K -165 ALMOND, 4X4 VERIFIED WALL ACCENT: DAL TILE, GR -17, 4X4 LEAFY GREEN ONE OF TWO COLORS ON SITE VERIFIED. THIS COLOR CAN BE USED AS ACCENT. m c C) r L1 I E E • o4 [z r- • (P J (� _. ..r(, • w a 1 SUSPENDED CEILING 10' -0" A.F.F. 4' –O" 5 -0" IC) N) 7\,/\/\/\ ✓'\ ■ nom Emiam. I! !iI'i ism • e / IL ROOM 171 CARPET TILE RESTROOM 177 ENLARGED PLAN SCALE: 1/2" – 1' •-- SF:24 0 rn I 1 -(( 2 FULL HEIGHT WALL SECTION SCALE: 3" = 1' — SF:4 0 6" CAULK ALL AROUND STD. MTL. FRAMING & FINISH PER PLANS, MATCH STUD SIZE TO EXISTING FRAME NOTE: VERIFY EXISTING WALL WIDTH WITH OVERALL EXISTING WALL THICKNESS. FINISH TO MATCH BUILDING STANDARD DOOR JAMB SECTION SCALE: 3" = 1' – SF:4 c 6" 4' BACKER ROD & SEALANT COMPRESSION TRACK ROOM 173 3 -5/8 " -20 GA MTL. STUDS AT 16" O.C. W/ 5/8" TYPE "X" GWB EA. SIDE CONT. MTL. RUNNER ANCHORED 4' –O" 0.C. TO FLOOR WALL BASE, TYP. EXPDXY FLOOR FINISH AS SCHED. BACKER ROD & CAULK H.M. FRAME SMOKE GASKET H.M. DOOR 1 15' -0" A.F.F. EXIST. STRUCTURE 25' -0" SUSPENDED CEIUNG 14' -0" A.F.F. RESTROOM 177 SUSPENDED CEILING O ROOM 173 EXISTING ADA STALL TO REMAIN AS IS 0 0 If L 11 FINISH TOP OF WB W /CORNER BEAD AND CLEAN FINISHED EDGE nJ SHOWER MTL. EDGE BEAD ( TOP RUNNER ANCHOR MAX. 4' O.C. 3 -5/8" 25 GA. MTL. STUDS MAX. 2' O.C. W/ 5/8" TYPE "X" GWB EA. SIDE CONT. MTL. RUNNER ANCHORED TO FLOOR, MAX. 4' O.C. WALL BASE, TYP. FINISH FLOOR FINISH FLOOR 6 " 1 ' BACKER ROD & CAULK NON - STRUCTURAL WALL SCALE: 3" = 1' – SF:4 NEW GWB CEILING 10' -0" A.F.F BACKER ROD & CAULK PARTIAL HEIGHT WALL AT RESTROOM SCALE: 3" = 1' – SF:4 ANGLE BRACE TOP OF WALL TO STRUC. PER IBC REQUIREMENTS ANCHOR 8' 0.0. MIN. MTL. EDGE BEAD N COMBUSTABLE BLOCKING --- BLACK TOP RUNNER ANCHOR MAX. 4' 0.C. 3 -5/8" 25 GA. MTL. STUDS MAX. 2' O.C. W/ 5/8" TYPE "X" GWB EA. SIDE CONT. MTL. RUNNER ANCHORED TO FLOOR, MAX. 4' 0.C. WALL BASE, TYP. EXIST. SUSP. CLG. SITE VERIFY 1 ' 0 RESTROOM 179 NO WORK CR LAURENCE D1O38A CLEAR SATIN ANODIZED HORIZONTAL SLIDING PASS –THRU ASSEMBLY WITH D7 OVERHEAD AND BOTTOM TRACK. (BOTTOM TRACK IS NOT ON PASS THRU SIDE) PROVIDE KEYED LOCK AT SLIDING WINDOW. P –LAM COUNTER WITH 6" RADIUS AT CORNERS NEVAMAR ET5001T CLOSE ENCOUNTERS METAL STUD FIRE TREATED WOOD BLKG GWB WALL PER DRAWINGS 8 MAX 1 II I II 1111111111111111111111111111111 . 1111111111111111111111111 1/8" POP RIVET ALL MEMBERS AT ONE WALL WALL ANGLE OR BERC 2 CUP MAIN RUNNER OR CROSS TEE #12 GA SPLAY WIRE BRACING IN PLANE OF EA MAIN RUNNER VERT ANGLE © 45° (12' –O" OC IN ALL DIRECTIONS. 144 SQ FT MAX) START WITHIN 6' OF WALL VERT SEISMIC STRU 12' OC EA WAY (1 -5/8" STUD) FASTEN TO MAIN RUNNERS & CUT TIGHT TO STRUCT; HELD IN PLACE W /VERT WIRE WIRE & HEAVY GA WIRE PIN 0 0 J PARTS & ALLOCATION 173 45 IMF PASS -THRU WINDOW SECTION SCALE: 3" = 1 — SF:4 6" #12 GA VERTICAL WIRE 1 CEILING GRID DETAIL SCALE: 3" = 1' – SF:4 6 " C ROSS TEE MAIN TEE 1' I l i 1 1 1 1 1 1 1 111111111111111 I I I I I11 1 1 111I I I111111111111111111I HORIZONTAL STRUT TYPICAL CONTINUOUS PROVIDE 1/2" SPACE AT NON – RIVETED WALL ACOUSTICAL CEILING TILE EAVY GA WIRE PIN 12 GA VERT WIRE HANGER C� 4' ---0" OC ALL HANGERS AND SPLAY WIRES TO HAVE A MIN OF 3 TURNS IN 1" OF RUN 45' 7 7'7' 45' 8 „ MAX CORRIDOR 1 150 / — PROVIDE NEW MANUAL PUSH –UP ROLLING FIRE SHUTTER AT 1 –HOUR WALL. AUTOMATIC CLOSING BY SMOKE DETECTION EQUIPMENT. CONTROLS AS REQUIRED BY UNDERWRITERS LABORATORIES. FINISH BAKED GRAY PRIMER. MAHON DOOR CORPORATION OR EQUAL. C " J C••1 PLYWOOD SUBDECKS. EXPOSED PLYWOOD SURFACES TO BE PAINTED WALL COLOR FINISH TOP OF GWB W /CORNER BEAD AND CLEAN FINISHED EDGE • NOTE: – SUSPENSION SUSPENDED PLAN FOR S – SUSPENDED ASTM C635 GRID SYSTEM TO BE COMPATIBLE WITH TILE SPECIFIED. SEE REFLECTED CEILING PECIFICATIONS. CEILING TO COMPLY WITH 2003 IBC, & ASTM C636, ASCE 7 -02 AND CISCA. 0 / 6 ' -0 " " DOOR ELEVATION SCALE: 3" = 1' — SF:4 6" / / 1 DOOR HEADER SECTION SCALE: 3" = 1' — SF:4 0 6" i RE — ...T CITY OF TUKWILA MAR 062008 PERMIT CENTER STD. MTL. FRAMING & FINISH PER PLANS, MATCH STUD SIZE TO EXISTING FRAME CAULK ALL AROUND H.M. FRAME (EXISTING) SMOKE GASKET H.M. DOOR NOTE: VERIFY EXISTING FRAME WIDTH WITH OVERALL EXISTING WALL THICKNESS. FINISH TO MATCH BUILDING STANDARD REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 1 2006 City Of Tukwila BUILD: ;C D. SION CORRECTION QT if6s 3912 Registration REGISTERED ARCHI ECJ DO LAS A. DIEL STATE OF WASHINGTON Key Plan Bar Code 5,heet Title ENLARGED PLAN AND DETAILS PERMIT DRAWINGS DATE: 02/12/08 sheet Title A=MO1 TUKWILA 2 BUILDING 3433 SOUTH 120TH PL TUKWILA, WA 98168 No. Dote 01 -10 -08 02-12-08 03 -04 -08 Design Drawn BD Checked DOUGLAS A. DIEL Date T JOAN HATCH EL 02/06/08 Internal Project No. K -07 -14901 M.S. Project No. P. 11170 Revisions Description BID DOCS PERMIT SUBMITTAL PERMIT REVISION #1 KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Design Team