HomeMy WebLinkAboutPermit D08-115 - WESTFIELD SOUTHCENTER MALL - FYE - TENANT IMPROVEMENT2636 SOUTHCENTER MALL D08 -115 Design Occupant Load: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D08 -115 Occupant /Tenant: FYE Building Address: 2636 SOUTHCENTER MALL, SUITE NO. Parcel No.: 6364200010 Property Owner: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 Use: RETAIL Occupancy Group /Division: M Type of Construction: II -B Automatic Sprinkler System: Provided: Y Required: Y 104 THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: 6364200010 Address: 2636 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: FYE Address: 2636 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Contact Person: Name: DEVON REDMON Address: 1327 POST AV, STE H , TORRANCE CA 90901 Phone: 310 328 -6330 Contractor: Name: CONSTRUCTIVE BLDG SERVICES INC Address: 3937 39 AVE , OAKLAND CA 94619 Phone: 510 - 531 -1175 Contractor License No: CONSTBS994D8 doc: IBC -10/06 CRAM' Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Permit Number: D08 - 115 Issue Date: 05/20/2008 Permit Expires On: 11/16/2008 Value of Construction: $48,000.00 Fees Collected: $1,326.15 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: IIB Occupancy per IBC: 0019 Expiration Date: 05/20/2010 DESCRIPTION OF WORK: INSTALL NON - STRUCTURAL TENANT FIT UP OF EXISTING RETAIL SPACE. WORK INCLUDES INSTALLATIONS OF PARTITIONS, DOORS, CEILINGS, FINISHES, AND FIXTURES AS INDICATED ON PLANS. * * continued on next page ** D08 -115 Printed: 05-20 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Main Extension: Water Meter: N Permit Center Authorized Signature: City dinukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Private: Public: Permit Number: DO8 -115 Issue Date: 05/20/2008 Permit Expires On: 11/16/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Date: v 'JO- I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will • e complied with, whether specified herein or not. The granting oft - • 441,E oes not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or � e p -� • - wor am authorized to sign and obtain this development • _ 't. Signature: / Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D08 -115 Printed: 05 -20 -2008 Parcel No.: 6364200010 Address: 2636 SOUTHCENTER MALL TUKW Suite No: Tenant: FYE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 - 115 Status: ISSUED Applied Date: 03/03/2008 Issue Date: 05/20/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 11: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the doc: Cond -10/06 D08 -115 Printed: 05-20 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 nun). Signs larger than the minimum established in section 1011.5.1 of the International Fire doc: Cond -10/06 D08 -115 Printed: 05-20 -2008 ID • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ei.tukwila.wa.us Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 35: Local U.L. central station supervision is required. (City Ordinance #2051) 36: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 37: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 38: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 39: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 40: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 41: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. doc: Cond -10/06 008 -115 Printed: 05-20 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 42: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 43: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 44: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 45: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** D08 -115 Printed: 05-20 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the p rformance of work. Signature: l ft(1/4,/ Print Name: � doc: Cond -10/06 D08 -115 Printed: 05-20 -2008 Name: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 lilt/: 1I1I ijik ti a. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 2 / \ King Co Assessor's Tax No.: 636 ¥2 - / Site Address: c )-,6 J6 So ` , c \ \ Suite Number: Tenant Name: ` Y Floor: / New Tenant: f / Yes WA ❑ ..No Property Owners Name: S d 'vim JC- Mailing Address: /16 t''415 ; {- j l v ` 9t/'rJ f 5 City (% State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Mailing Address: I 3 027 fo3 f d -oy»_ / cit Co✓"7Fax Number: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: ty Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: rcvec. \ so t c V j to nv\- Q:\Applications \Fortes- Applications On Line13 -2006 - Permit Application.doc Revised: 9 -2006 bh • Building Permit No. Mechanical Permit No. Day Telephone Jc 3„2,5" 6 5 '(o rr a et CO.-- 6t/ 9t10 f Project No. ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Company Name: ( v tom/ 1 G�.1C � / (!?/ �. " A r ^ C [vt Mailing Address: T// / i icier g �r I t�n•A-o Plumbing/Gas Permit No. Public Works Permit No. 6 a / � 7 f a � Contact Person: Day Telephone: t�) — 6 3S 6 yG E -Mail Address: Fax Number: 91? 6 3 .5 - Company Name: W V7 e / r' 499 (cc) 5U1 Mailing Address: 63" W, nod S kf.•e sfe' 111010274 City Day Telephone: Fax Number: (For office use only) vo 1(C AA Ply State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record 1 n-gt t'1.2-2i rt 1 Gs r� 53438 g5 D- State 6 -to 7 o 4 s� 3H - Ll /$I Page 1 of 6 BUILDING PERMIT INFORMA'T'ION - 206 - 431 -3670 • 14 15 CV Scope of Work (please provide detailed information): Tr e j � I n /1 S77 VL Valuation of Project (contractor's bid price): $ f Existing Building Valuation: $ tvra a ill cri7 �d / c /. o r C '! li - . � Will there be new rack storage? ❑ Yes o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: / Compact: Handicap: Will there be a change in use? ❑ Yes Jam .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Saf Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: WpplicationsWonns- Applications On Line\3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 2 Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMA'T'ION - 206 - 431 -3670 • 14 15 CV Scope of Work (please provide detailed information): Tr e j � I n /1 S77 VL Valuation of Project (contractor's bid price): $ f Existing Building Valuation: $ tvra a ill cri7 �d / c /. o r C '! li - . � Will there be new rack storage? ❑ Yes o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: / Compact: Handicap: Will there be a change in use? ❑ Yes Jam .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Saf Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: WpplicationsWonns- Applications On Line\3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser i d.... 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct j Thermostat r 1 �+ 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750.000 BTU Repair or Addition to Heat/Refri Coolin System g Incinerator - Domestic Other Mechanical Equipment V0i box2 2 zwi g00 (�'� �c• t;�^ Air Handling Unit <10,000 CFM Incinerator — Comm/1nd • MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRA INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ Scope of ork (please de detailed information): cg Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q:\ApplicationsWorns- Applications On LinM3 -2006 - Permit Application. doe Revised: 9 -2006 bh \, 000 c 3 M r` -' o v, 4 ete-$7-5 Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) f Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain / Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory , Water Closet J Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent / Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment 1 Repair or alteration of drainage or vent piping ` Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3�0 PLUMBING AND GAS PPIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide de iled i ormation): . � v C ? t Building Use (per Int'l Building Code): Alte Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:tAppliwionsTonns-Applications On Line13 -2006 - Permit Application.doc Revised: 9.2006 bh Sewer: Page 5 of 6 Date Application Accepted: of o3 g� Date Application Expires: ti 10 Staff Initials: • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI7 Dv�`�_ Signature: ��- , --c-- Date: 2,--2 D —� Print Name: eDe o Day Telephone: / a o ° X .1 0 69 Mailing Address: ( " i 51-e 44 f o r{'Gc ✓t CQ (4 City State f ;95 Q:Wpplicahons\Forms- Applications On LineO -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 Parcel No.: 6364200010 Permit Number: D08 -115 Address: 2636 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/03/2008 Applicant: FYE Issue Date: Receipt No.: R08 -01724 Initials: WER User ID: 1655 Payee: CONSTRUCTIVE BLDG SERVICES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7747 805.50 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Account Code Current Pmts 000/322.100 000/386.904 RECEIPT Total: $805.50 Payment Amount: $805.50 Payment Date: 05/20/2008 10:17 AM Balance: $0.00 801.00 4.50 2646 05/20 9711 TOTAL 1222.50 doc: Receipt -06 Printed: 05-20 -2008 Doc: RECSETS -06 RECEIPT NO: R08 -00594 Initials: JEM Payment Date: 03/03/2008 User ID: 1165 Payee: EXPRESS PERMITS SET TRANSACTIONS: Set Member Amount • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us SET ID: S000000972 SET NAME: Tmp set /Initialized Activities D08 s2. 1 520.65 EL08 -204 98.40 M08 -061 63.25 PG08 -066 32.00 TOTAL: 714.30 TRANSACTION LIST: Type Method Description Amount Payment Check 11076 714.30 TOTAL: 714.30 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT • Total Payment: 714.30 Account Code Current Pmts 000.345.832.00.0 98.40 000/345.830 615.90 TOTAL: 714.30 9310 03/03 9710 TOTAL 714030 Project: b .... 17 / 5 Type of Inspection: , \ Address 36 /YI _ / ( Date Called: Special Instructions: Date Wanted: 743 /40 ? a.m. Requester: Phone No: q DDS ?JS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 COMMENTS: e_. ,447/e-/e. A; ;4 Ai Approved per applicable codes. EJ Corrections required prior to approval. $60.0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: (Date: ._._�4�. �• �! �bi2 _ -� __ t._ wl_,__& 'ICd9pe'. a - - - � Project: • fil Type of Inspection: // jj ` Address: 2(e7& 04i+1 - Date Called: /' Special Instructions: Date Wanted: .7_22......8„. a.m. p.m. Requester: Phone No: q INSPECTION NO. INSPECTION RECORD pof - 1 /5 Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36ij0 ® Approved per applicabl"e codes. El Corrections required prior to approval. COMMENTS: S1 - .z /,L1 CIyS f/ /Cl:4;.5 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: q — Type of Inspection: CSI IS F AIL D CF /LAX Address: _.Cc,3 6:, ill it Date Called: Special Instructions: . Date Wanted: --- — 1 0 — GU u p.m. Requester: Phone No: z� -Szc 3 L ? INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ok (inspector 'Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project:/ a Type of Insp Address: ¢ Date Called: Special Instructions: Date Wanted: 2-- !- ob 4ry p. m. Requester: Phone No: ( gal 323r 7 INSPECTION NO. INSPECTION RECORD - Retain a copy with permit 1206' - tt5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (06)431 -3F{7 El Approved per applicable codes. 0 Corrections required prior to approval. 0 $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: AfLor ,0l cue./ [Wei" / 06? c7 ,t/) 5r�c t�• eel /. !IPS ?. Date: 7 / 1 9 Receipt No.: Date: Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: 2 Z 7 - ar" p.m. Requester: Phone No: c INSPECTION NO. INSPECTION RECORD Retain a copy with permit »o3-/ ( PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 88188 (206)431 -3670 LZI Approved per applicable codes. El Corrections required prior to approval. COMMENTS: I ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4 jn Project: _ f 1 }� li Ty of Inspection: rr<i",� Address 2.6.3 & ma( Date Called: Special Instructions: Date Wanted: 4 —/q -4'r a.m. VZ Requester: Phone No: 02 S)21- 36238 INSPECTION NO. INSPECTION RECORD Retain a copy with permit po6 -1fS PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 7 A ! rclLuA I ff 5 c,.e Inspect Date: i$ Ei $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: ^ :A :: P�'. y' �i�sl�st��a� .�L '.�»P�rG.sa... ;Itit'`.�ao!is`iShrrl - a • -.s r..,?�r� :� sa;,.,re ...��.... �.. . Project: Type of Insp Address: _2 J / / Date Called: Special Instructions: Date Wanted: C / / 621 d p.m. Requester: Pho_ne o: 9 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 1:24 ((..i 1 J �G1' /4 ., / �S l — A l_ Inspector: Date: se ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite j D .e tl to schedule reinspection. Receipt No.: 'Date: Project: F f!!'' g Type o1 Ins ction: /7/77/6, Address: 2 631; ,yi7 Date Called: Special Instructions: Date Wanted: .ce a m. Requester: Phone No: G 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION e- 6300 Southcenter Blvd.,t #100, Tuuwila - WA 98188 (206)431 -3670 El Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: jJX bAzi A L i, 5 P?tJes CO �';c�� �• Date: El $60.0 FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: Type of Inspection: Ad s 7% dm I9// Date Called: Special Instructions: Date Wanted: a.m Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IR 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. EI Approved per applicable codes. ['Corrections required prior to approval. Date: $6x.00 REINSPECTION FEE - REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: Date: e COMMENTS: 1 ,9/4 o k- tire: .,. _•:n - n,.e:_ COMMENTS: Type o ectio (595 te was/ Pari m w e, 4.471k i./ /4 Ar k J( i, iIt AI S'9 Date Called: s u Alb 4 Date Wanted: + a* WI // cf 49 s � ,,4d; Requester: Phone No: Project: / Y( Type o ectio Address: Date Called: Special Instructions: Date Wanted: a.m. 6 . Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Ins`nectoF: Date 3 -d6 $ 0 REINSPECTION FEE REOUIRED rior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: ;, i_da—e . <i+4''5� '°'°.. .,,g,.:. COMMENTS: A p N 'E7 Fro?,b...frt? Lti4 (.•,kfI 1.Th/ Pee . rill /4 -'1 1 .W ''t, 1.41.15 . Addre, ( � A c / Date Called: Special Instructions: Da te d a.m '� an �- �]� p.m. Requester: Ph ne No: L-12,-5-boact -3 2:3A,, 6 4 Prole T of Inspe tion: Addre, ( � A c / Date Called: Special Instructions: Da te d a.m '� an �- �]� p.m. Requester: Ph ne No: L-12,-5-boact -3 2:3A,, 1 NI Approved per applicable codes. DOg - I INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IF- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 orrections required prior to approval. Date: Z- Inspector: J $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: h l' �..' IT�E. rT ihiC ��rJ�. �lis ` s';:�sr��sA`�4�'- • �:xi.�.�:.0 .�_R�,. �.LLS.��:..�:Yn::..;..� _ Project: fl Sprinklers: Type of Insp ion: (� f s5 \ s;re .� s vtlit -( Address: ,( 6, Suite #: 5..C. f✓a-L L_ Contact Person. Special Instructions: Monitor: Phone No.: Pre -Fire: Needs Shift Inspection: J" Sprinklers: Fire Alarm: V Hood & Duct: oN-) Monitor: o\ Pre -Fire: Permits: 40 - .Occupancy Type: 4r "' •Z0".aC:. :.d�^: .' .: f2A r'..i: d INSPECTION NUMBER „ . : . r o t a : o-• .4; INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT UV -11s- PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 5) I/ Date: - 2/93/ 0 g Hrs.: ' $80.00 REINSPECTI FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. • Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 - - -- - - - - Project: - -- - - - - -- - Fire Alarm: Type 9f Insp 'on: Address: a G 3 (0 Suite #: S . L , M,L Permits: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 r7 Approved per applicable codes. • INSPECTION RECORD Retain a copy with permit C 2— S — 0 1 _ 1 5 . 7_ poV - / /. ®FS - F - 7 PERMIT NUMBERS ections required prior to approval. COMMENTS: ec,L —0 ic- oX- / 9 j - , c1 5 4 . 1 Ira Inspector: 4,r� / y 1 Date: Z/ a 4,6" Hrs.. . 1 61-1 / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 .r5; Project: y a ,• Sprinklers: Type of Inspection: V Address: . Suite #: : c ' r; C it ,_,• Contact Perso Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permit: Occupancy Type: 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 COMMENTS: /4y bet) 6 ga.? 13 - 5 0 Re i ∎ 1-- d(9-o 15.3 1 Inspector: Date: er•1 2 /d . e24. Hrs.. INSPECTION NUMBER proved per applicable codes. INSPECTION RECORD Retain a copy with permit Word/Inspection Record Form:Doc 1/13/06 CITY OF TUKWILA FIRE DEPARTMENT - tr7 Dom► ► i" PERMIT NUMBERS Corrections required prior to approval. $80.00 REINSFECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. T:F:D. Form F.P. 113 Project Info -- 1 - 34: 1 Project Address "FYE" south Center Mall Date 2/21/2008 Area in ft For Building Department Use �© FILE C ;P / li 1, ...dbiZttle, Retail WA. 98188 Applicant Name: W.J. Sutherland & Associates Inc. Applicant Address: 6300 W old Shakopee Road Bloomington, MN. 55438 Applicant Phone: 952 - 346 -4180 , FAX = 952- 346 -4181 Perrnit Project Description LJ New Building ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for contro E endreornmissioriing 'requirements 40 (1.11.°"1 .fl* Compliance Option 0 Prescriptive ® Lighting Power Allo Q Systems Analysis.'" �. (See Qualification Checklist (over). Indicat Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft Area in ft Allowed x Area 1st Floor Retail 1.50 3631.0 5446.5 Sales "D" 1 -50w MR16, 4" Downlight, Recessed Flood ® m. - 50.0 150. 0 _ Sales "Dl" 1-70W PAR38, MB FL IrEV EtlMED9�_ 3 00 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 5446.5 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales "A" 3 -40w Fluorescent U -Tube 36 92.0 3312.0 Sales "D" 1 -50w MR16, 4" Downlight, Recessed Flood ® m. - 50.0 150. 0 _ Sales "Dl" 1-70W PAR38, MB FL IrEV EtlMED9�_ 3 00 1�� 70.0 1050.0 Toilet "F" 1 -100W Incandescent, Fan/Light Combo 1..E CO'J LL j 1 CE 100.0 100.0 Sales "PL" 2 -42W CFL, 9" Downlights, Recessed ['1 ° °'" t l� °��+2 94 • 0 188.0 Sales "N" 1 -50W, NEON * A a r. _ 1 I 54.0 54.0 Stock /Corridor "SF" 2- F32T8, Surface Mount, 48" MAR C f) MIA 7 t 58.0 406.0 0i J Of TukiN N RI III rex, "pki;lc. Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 5260.0 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting ;Summary 2006 Washington Slate Nonresidential Energy Code Compliance Forms Revised July 2007 Maximum Allowed Lighting Wattage Proposed Lighting Wattage Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. clr 'cctn ► .• ' ,•t `^ii :EIVFD CITY Ui 1 UKV1ALA MO 0 3ZOOS PERMIT CENTER Use' LPA (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet/conference /exhibition hall 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. ;Interior Lighting Summary ;(back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 TABLE 15 -1 Unit Liahtinq Power Allowance (LPA Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Lighting, 2006 Washington State Motor, and Transformer: Permit Plans Checklist LTG-CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address �• South Center Mall Date 2/21/2006 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 I Max. watts 'Indicate watts for each exit sign I I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) yes I 1540 (Transformers 'Indicate size and efficiency I I 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location VAV -1 Trane VPEF12 -- 1800 By L.L. -- -- Above Ceiling VAV -2 Trane VPEF12 -- 1800 By L.L. -- -- Above Ceiling 17000 0.990 CODE OM i ACE Y P PM MP. 0 3 Z008 PERMIT CENTE NNAK 8 [MTh Fan Equipment ScheL �� Brand Name' Model No.' Equip. ID Brand Name' I r AUK Bu mod " pN'o'' ' f u NIid ITC',GF1M sP' HP /BHP Flow Control Location of Service VAV -1 Trane `VPEF12 1100 5'5' 0.50 0.33 VS Above Ceiing VAV -2 Trane VPEF12 550 0.50 0.33 VS Above Ceiigtp CITY OF TOKYO 17000 0.990 CODE OM i ACE Y P PM MP. 0 3 Z008 PERMIT CENTE Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' VAV -1 Trane VPEF12 1 1100 By L.L. 17060 17000 0.990 Applicant Phone: 952 - 346 -4180 v A V - 2 Trane VPEFt V1E VVlltU UI 7706 1100 By L.L. 17060 17000 0.990 CODE OM i ACE Y P PM ED NNAK 8 [MTh Project Info Project Address'/ South Center Mall Date 2/21/2008 For Building Dept. Use FlI C! PY �° o �itL 1 1� 6ea4t1a, WA 98188 Applicant Name: W.J. Sutherland & Associates Applicant Address: 6300 W Old Shakopee Rd Suite 140 Bloomifgtop Applicant Phone: 952 - 346 -4180 Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans 2006 Washington State Nonresidential Energy Code Compliance Form I C ; r Include documentation requiring compliance with commissioning requirements, Section 1416. Revised July 2007 Tenant space with two (2) fan powered VAV.boxes unde406 0f0fCIt! to Emirs and c All mechanical cooling and ventilation are provided by landlord HVAVirlit 0►11j.5 d z . not code related requirements are landlord's sole responsibility. Compliance Option Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. ' COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). OINP IIC :R System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? • Mechanical Sur rnary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. C START System Type Heating Only y <5000 \_ N cfm? No 2006 Washington State Nonresidential Energy Code Compliance Form Reference Yes -; Heating/Cooling Air Cooled, or Cooling Only 'NConstant Vol? Econo Cool Cap, <70 %OSA`. Yes ■ No-► <20,000 Jnduded ?. '.Btuh? Yes Yes • r - Reference- Section 1423 ) 1 /Total wo economizer -, N<240,000 Btuh Nor 10 %?v N Simple System Yes �► Allowed I--- - - - - -- - (section 1420) 1N Section 1421 ) Yes Y n - Bingle�. Split System \ Package r No -0- <= 84,000 -- N1 Yes Unit? - N_ Btuh? I Nv" Yes o r s' Al'CJ Outdoors or Nor Adjacent to .> Yes "Outdoors. N ool Cap Yes - K <54,000 No \B\j? \✓ No No r V Use Complex ►I Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical 2006 Washington State Perm;it Plans Checklist MECH -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address South Center Mall 'Date 2/21/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans M -1 yes 1412.2 Deadband control Indicate 5 degree deadband minimum M -1 n.a. 1412.3 Humidity control Indicate humidistat yea 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types M -1 n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage yes 1412.4.2 Optimum Start Indicate optimum start controls M -1 n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans M -1 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas yes 1422 Thermostat interlock Indicate thermostat interlock on plans M -1 n. a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M -4 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M - 4 n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan M -4 yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing M -4 yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training M -4 yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M -4 n.a. 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping M -4 n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 4 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: ACTIVITY NUMBER: D08 -115 DATE: 03 -20 -08 PROJECT NAME: FYE SITE ADDRESS: 2636 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: ing 'vision ' Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03 -25 -08 Complete TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: o d REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Fire Prevention Incomplete Structural Review Required Approved with Conditions n DATE: DATE: Planning Division F Permit Coordinator Not Applicable Comments: ❑ No further Review Required n Et Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 04 -22 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -115 DATE: 03 -03 -08 PROJECT NAME: FYE SITE ADDRESS: 2636 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ing Uivision M PERMIT COORD COPY � PLAN REVIEW /ROUTING SLIP 6 L 34oi F ire Prevention Planning Division Public Works X1 Structural "0 41 N bu 4 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03-04-08 _ Complete Ff Incomplete n Not Applicable n Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 Structural Review Required Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DATE: Permit Coordinator DUE DATE: 04-01-08 Approved Approved with Conditions n Not Approved (attach comments) [Fr Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: V �D Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: L� Q;01;1170 Q,at), Q 013 - :•0` b '� 11' cisto 04Q13Th' 711 N.I teldor Road • Arlington, T X 76012 • 1. 817.635 5696 • 1: 817.635.5699 March 20, 2008 City of Tukwila Department of Community Development 6300 Southcenter Blvd., Suite #100 Tukwila, WA 98188 Attn: Allen Johannessen Re: FYE 2636 Southcenter Mall Development Application Number D08 -0e8 ! -.115 Dear Mr. Johannessen, Per your conversation with our project coordinator David Sorgman, on March 19, 2008, please accept this letter as our response to your review comments dated March 10, 2008. The numbers listed below coincide with your comments. Architectural Comments: 1. The area labeled as an "egress corridor" within the tenant's leased area is a non -rated corridor as defined in section IBC 2006, section 1017.1. The space is protected by an automatic sprinkler system, fire rating is not required. The space is being constructed solely to define the path of egress to the rear exit of the store. Compliance with IBC 2006, sections 708.1, 708.4, and 715.4.4 is not required. 2. Means of egress illumination shall meet the code requirements of 1 foot candle at the walking level. I trust that this response meets with your approval. Please feel free to contact our project coordinator, David Sorgman at (781) 331 -4000, ext. 205 with any questions. Sincerely, Cortland Morgan, Architect • LCT i " 7 AN CORRECTION • MAR 2 0 2008 Ehiv i CENTEh March 10, 2008 Devan Redmon 1327 Post Avenue N, Suite H Torrance, CA 90501 RE: CORRECTION LETTER #1 Development Application Number D08 -098 FYE — 2636 Southcenter Mall Dear Mr. Redmon, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen, at 206 - 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, 4.14ak kive Brenda Holt Permit Coordinator encl xc: File No. D08 -115 P:\Permit Center \Correction Letters\2008\D08 -115 Correction Ltr # 1.DOC wer • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 1 R 2nn C••ito $inn • T111.U/11, !,Vochinrrtnn ORIRR • Phnnv• 21ti- 4 ?1 - 71571) a Far- 2n5- 431 -1R/tS Building Division Review Memo • • Date: February 07, 2008 Project Name: FYE Permit #: D08 -115 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. An egress corridor is shown at the back of the store. Unless for what ever reason a corridor is required, the recommendation would be to identify this as an exit access hallway or hall. Otherwise the corridor shall be required to meet the code for corridor construction. In this case the existing mall corridor is beyond the exit door where this would not be required to be a corridor. Please revise plans to identify this as an exit hallway. (IBC 708.1 & 4, 715.4.4) 2. The means of egress shall not be less than 1 foot -candle at the walking level. Please identify sufficient egress illumination on the plan that meets egress illumination. Egress illumination shall extend to the exterior landings or exit discharge doorways. (IBC 1006.2& 1006.3 #5) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. Date: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fad etc. / /O Plan Check/Permit Number: ❑ Response to Incomplete Letter # Response to Correction Letter # j ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner I - 1/5 Project Name: 1` Y / Project Address: Z6, 3� 5 4 4i ceek- Ma ( l j 7itiL„ i!_ ) 1,0�- `� 81Sg Contact Person:II Q,U Ses-le Phone Number: 7/- SS/ —moo x-.0.5 Summary of Revision: (� SQ 1 N tf le- r P S c'_ - 14 - r Y 5-c PIECE W CITY OF TUKWILA MAR 20 ?nnn Sheet Number(s): "Cloud" or highlight all areas of revision including date of rev Received at the City of Tukwila Permit Center by: I Entered in Permits Plus on � � - - - O \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Rowiar • February 28, 2008 • • Tukwila Building Division / Permit Center 6300 Southcenter B1, Suite 100 Tukwila, WA 98188 Re: f.y.e. Music Movies 2636 Southcenter Mall; Space 2110 Tukwila, WA 98188 is issued subject to the following condition: This condition is hereby acknowledged by: Tenant Acknowledgment Letter iyacf±n E L4 MAR 1 2 2008 �'EkM17 Cfd TEA Tenant improvement permit for f.y.e. Music Movies, Tukwila Permit No. poi - 116 Final inspection approval of this permit and approval of occupancy (i.e. Open for Business) for the herein named tenant space will not be issued until the "shell Building Permit No. D06 -147 has received final inspection approval from the Building Division. Title (1): TXed:UT) ul, V 4 I/ 4.. Tenant Name: F' Mu5►c 1v 1 OV (E5 (1) Note that the letter is to be signed by the responsible officer of the tenant (i.e. business manager, business president, vice president, CEO, etc.). The contractor, contact person for the project nor the architect will not be acceptable. Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 1. Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 ?„ Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 1 6 Water closet, tank or valve, >1.6 GPF 8 4 Non - Residential • Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type S \ Property Street Address A � n (V K� i la, J}l� g City ( State ZIP Owner's Name Subdivision Name Lot #_ Subdiv. # Block # Building Name C r C. • ( 1 ) (if appl able) 0 F C I Owner's Phone Number (with Area Code) City or Sewer District ( s g O ) 1 3 -' I '1(4 e , c .}- 7/(g? Date of Connection Side Sewer Permit # Demolition of pre- existing building? ❑ Yes ❑ No Type of building demolished Sewer disconnect date Property Contact Phone Number (with Area Code) Owner's Mailing Address ,�;�- \,\vc,' �r s f-Q I -.& S c J f q"o 6 Z5 p iccor A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units = 1058 (Rev 11/05) 20 Total Fixture Units lit a y.5 RCE For King County Use Only Account # Monthly Rate 6 Month Rate Property Tax ID # 1...3t, Y22, - C50 in Party to be Billed (if different from owner) I 5 Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi- annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of rrected data for de i tion of evised capacity charge. Date Signature of Owner /Representative ���'�"� �� , � - 'r"` a?` a Print Name of Owner /Representative X10 :T \ Neal ..1 t� • RCE White - King County Yellow - Local Sewer Agency Pink - Sewer Customer B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) = 187 C. Total Residential Customer Equivalents (add A & B) CITY RECEIVED A r NS MQR 0 3 2008 PERMIT CENTER King County Department of Natural Resources and Parks RCE License Information License CONSTBS994D8 Licensee Name CONSTRUCTIVE BLDG SERVICES INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602003542 Ind. Ins. Account Id 0 Business Type CORPORATION Address 1 3937 39TH AVE Address 2 City OAK LAND County OUT OF STATE State CA Zip 946192201 Phone 5105311175 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/15/2001 Expiration Date 5/20/2010 Suspend Date Separation Date Parent Company Previous License CUMMIC *066DB Next License Associated License Business Owner Information Name Role Effective Date Expiration Date CUMMINGS, JEFFERSON D PRESIDENT 03/28/2001 Impaired Date HOWARD, JEFFREY W SECRETARY 03/28/2001 DEVELOPERS SURETY & INDEM CO Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 DEVELOPERS SURETY & INDEM CO 846283C 03/06/2002 Until Cancelled $12,000.00 12/28/2001 Look Up a Contractor, Electrien or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= CONSTBS994D8 05/20/2008 Key to Divisions of Work FURNISHED I INSTALLED ED CSI C CSI SHEET DESCRIP110N /NOTES LANDLORD TENANT TENANT'S CONTRACTOR LANDLORD TENANT TENANT'S CONTRACTOR 1 O NLSIX3 00 CONTRACT REQUIREMENTS 1 Bonds(if required) 0 00600 T T -1 P Payment /Performance Bond shall • • 01 GENERAL 1 Permits and Fees 0 01000 I I- I- I- Per Scope of Work • • I o00 02 SITE WORK 1 Selective Demolition 0 02070 A A - 1 F For Rear Egress Door 0 0 0 0 03 CONCRETE 1 Concrete slab A A - 1 Q Q 04 MASONRY • - - - 05 METALS 1 Misc. Metals 0 05000 A A -1 S See Technical Specification on N -1 2 Light Gauge Framing 0 05400 A A1,N1 S See Partition Schedule Sheet A -1 0 0 3 Metal Furring Channels 0 05000 A A -1 I If Required 0 0 4 3/4 ° x3/4 ° Wall Angle 0 05000 A A -2 S Slatwall Trim,See Detail Sheet A -4 5 1 "x1" Wall Angle 0 05000 A A -1 S Sales Area Columns 6 Metal U– Channel 0 05000 A A -1.1 S Storefront 06 WOOD AND PLASTICS 1 Rough Carpentry 0 06100 A A -1 S See Technical Specification on N -1 • • 2 Finish Carpentry 0 06200 A A -1 S See Technical Specification on N -1 3 Toggle Bolts 0 06200 A A -1 S See Technical Specification on N -1 • • 4 Misc. Wood Trim 0 06220 A A -2 • • 1/A 5 Particle Board Valance 0 06220 6 Plastic Laminate 0 06240 A A2,F1 • • Fixtures 0 0 7 Hardboard Panels 0 06255 A A - 2 P Prefinished (Slatwall) 07 THERMAL/MOISTURE 1/A 1 Thermal Batts/ Rigid Insulation 1/A 2 Sound Batts • • 0 O 0 O O 0 T I C I-c C L 00 00 00 0.1 Material Symbol K :y El= Nifilail Symbol Key 5 A UD ►1C ' I PLYWOOD GLASS � — CSI SPECIFICATION DIVISION NUMBER SHEET NUMBER KEY TO WALL & FASCIA FINISH SCHEDULE EY TO FLOOR FINISH SCHEDULE Q KEY TO CEILING & SOFFIT FINISH SCHEDULE KEY TO WALLS AND PARTITION SCHEDULE Fire Ratings CARPET MILLIKEN MODULAR – TONAL VISTAS CLASS "1" RATING CRITICAL RADIANT FLUX– ASTM TEST E -648 : >0.45 W /CM' OPTICAL DENSITY OF SMOKE– ASTM TEST E -662 50 FLAMING WALL PARTITIONS SALES TO STOCKROOM: NEW NON –RATED PARTITION TENANT TO TENANT: 1 HOUR RATED PARTITION TO ABOVE CEILING; PER UL 1 -465 TENANT TO SERVICE CORRIDOR: 1 HOUR RATED PARTITION TO DECK; PER UL 1 -465 CEILING SYSTEM CEILING SYSTEM: CLASS "A" FINISHES SLATWALL• CLASS "C" PLASTIC LAMINATE: CLASS "C" MOUNTED TO CLASS "A" VINYL COMPOSITE TILE: CLASS "1" VINYL COVE BASE: CLASS " 1 " FLOOR TILE: CLASS "1" Copyright ACOUSTICAL CEILING CONCRETE BATT /LOOSE INSULATION STEEL FINISHED WOOD GYPSUM WALLBOARD BLOCKING /ROUGH LUMBER RIGID INSULATION PARTICLE BOARD ITEM, NOTE OR UNE NUMBER ELEVATION KEY NUMBER SHEET NUMBER DETAIL OR SECTION KEY NUMBER These drawings shall remain the exclusive property of THE ARCHITECT and its Consultants. All rights and privileges are reserved by the design team. The designer's liability is limited to the extent of their fee. These drawings shall not be duplicated without prior written permission of The Architect. c 7 ARAi PERMIT AND {,' �PROVAL F. :WIRED Schedule of Drawings T -1 T-2 A -1 ARCHITECTURAL FLOOR PLAN / PARTITION & DOOR SCHEDULES A -1.1 A -1.2 A -2 A -3 A -4 F -1 N -1 P -1 M -1 M -2 M -3 E-1 E -2 E -3 TITLE SHEET EGRESS PLAN STOREFRONT ASSEMBLY / MISC. DETAILS STOREFRONT ELEVATION / FLOORING PLAN INTERIOR ELEVATIONS / FINISH SCHEDULES REFLECTED CEILING PLAN / LIGHT FIXTURE SCHEDULE MISCELLANEOUS DETAILS FIXTURE PLAN NOTES AND SPECIFICATIONS PLUMBING PLAN AND SPECIFICATIONS MECHANICAL PLAN SPRINKLER PLAN MECHANICAL SPECIFICATIONS ELECTRICAL LIGHTING PLAN ELECTRICAL POWER PLAN ELECTRICAL SPECIFICATIONS & SCHEDULES Store Data (FOR STORE USE ONLY) AREA DISTRIBUTION 'PLAN DESIGNATION QUANTITY PERCENTAGE OF AREA 1. GROSS LEASED AREA 3,631 S.F. 100.0 % 2. SALES AREA 3,142 S.F. 86.5 3. STOCKROOM 345 S.F. 9.5 4. TOILET ROOM 62 S.F. 1.7 5. EGRESS CORRIDOR 82 S.F. 2.3 NORDSTROM SEARS Key Plan N.T.S. 08-11 Project .Information APPLICABLE AND MODEL CODES: International Building Code 2006* National Electrical Code 2005* International Mechanical Code 2006* Uniform Plumbing Code 2006 International Fire Code 2006* ANSI -117 -1 2003* ADA Guidelines * with the WA State Building Codes Amendments And all accumulative supplements thereof WA State Energy Code CODE ANALYSIS: USE GROUP: CONSTRUCTION TYPE: SEISMIC ZONE: FIRE SUPPRESSION: LIVE LOAD: MEANS OF EGRESS /OCCUPANCY LOAD SEE SHEET T -2 FOR ADDITIONAL INFORMATION MACY'S MOVIES I – I J NOTE: MAXIMUM NUMBER OF EMPLOYEES ON SITE AT ANY ONE TIME IS 4. SPACE IS LOCATED WITHIN 300 FT OF PUBLIC ACCESSIBLE RESTROOMS. SCOPE OF WORK: THIS PROJECT IS A NON– STRUCTURAL TENANT FIT UP OF AN NEW SPACE WITHIN WESTFIELD SOUTH CENTER. WORK SHALL INCLUDE THE CONSTRUCTION OF NEW INTERIOR PARTITIONS, DOORS, CEILINGS, LIGHTING, AND THE INSTALLATION OF ALL RELATED FIXTURES AND FINISHES. NEW HVAC SYSTEM AND ACCESSIBLE TOILET ROOM ARE REQUIRED. SEE DRAWINGS FOR ADDITIONAL INFORMATION. ALL WORK SHALL COMPLY WITH THE APPLICABLE CODES AS NOTED ON THIS DRAWING. BUILDING DEPARTMEN City of Tukwila Department of Community Development Contact: Dave Larson Phone: (206) 431-3678 6300 South Center Blvd #100 Fax: (206) 431-3665 Tukwila, WA 98188 NOTE: SPRINKLER AND FIRE ALARM WORK TO BE PERFORMED UNDER SEPARATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPARATELY. t i n'Y f.y.e. JCPENNEY SPACE # 2110 LEVEL 2 OF 3,631 SQ. FT. M – MERCANTILE 2B UNPROTECTED,NON – COMBUSTIBLE, FULLY SPRINKLERED CLASS D AUTOMATIC SPRINKLER SYSTEM 100 PSF City of Tukwila BUILDING DIVISION r-oc , c� c. \\9 .. - REVISIONS et ! changes shall be made to the scorn (f work . ,vithotit prior approval of Tukwila wilding Division P PVisions will require a new plan submittal - nay 'idlude additional plan revia9r Tees FILE OPY Permit No Plan review approval is subject Approval of construction documents c 01 ordinance. Receipt of any , �.=.i� of approved Field ! 4 and code= is acknowledged: 0 By Date: SEPARATE PERMIT REQUIRED FOR: 1MeGhanical [Electrical ��Plumbing Gas Piping City of Tukwila BUILDING DIVISION Southcenter Mall Space # 2110 2636 Southcenter Mall Seattle, WA 98188 RECEIVED cm( OF TUK ILA MAR 032008 PERMIT CENTER O Contract Requirements 00002 — PROJECT DIRECTORY LANDLORD'S REPRESENTATIVE: Westfield Corporation Inc. Contact: Josh Kimmel 11601 Wilshire Blvd 12th Floor Los Angeles, CA 90025 TENANT: Trans World Entertainment Corp. Contact: Allison Rivers 38 Corporate Circle Albany, NY 12203 TENANTS COORDINATOR: Bay Planning Company, Inc. Contact: David M. Sorgman 25 Mathewson Drive, Suite 200 Weymouth, MA 02189 SUBCONTRACTOR: Subcontractors are those individuals and /or Companies providing services, products and portions of the Work, described in the technical drawings and specifications, under direct . contract to the Tenant's Contractor. Requirements 01000 — GENERAL The Tenant's Contractor and all Subcontractors shall perform their Work according to the following: EXISTING CONDITIONS A. Prior to submitting bid proposals, the Tenant's Contractor and each Subcontractor shall visit the proposed space and make themselves familiar with all existing conditions, take field measurements and record all information needed to provide a complete scope of Work. B. Notify the Tenant immediately of conditions which may contribute to unnecessary, excessive costs. C. No additional compensation will be paid by the Tenant for disputes which result from a lack of familiarity with the existing conditions. 01035 — MODIFICATION PROCEDURES SUBSTITUTIONS & CHANGES D. DO' NOT substitute materials, equipment or methods unless such substitution has been approved specifically in writing by the Tenant. E. Notify the Tenant immediately by telephone of any hidden, unforeseen conditions and any requirements imposed by the Landlord which impact the Work. Confirm all notifications and action required in writing within 24 hours of the event. F. Milestone date changes must be made in writing by Tenant. 01040 — COORDINATION G. The Tenant's Contractor and each Subcontractor shall be thoroughly familiar with the Work shown on the drawings and on the other Contract Documents. H. Each Subcontractor shall coordinate their Work with that of others and be aware of all Related Work to be performed by others, via the Tenant's Contractor. 01060 — REGULATORY REQUIREMENTS 1. Comply with all applicable National, State and Local codes. See Project Information on this sheet. Phone: (310) 893 -4761 FAX: (310) 575-5991 Phone: (781) 331 -4000 FAX: (781) 335 -2115 Phone: (518) 452 -1242, Ext. 7489 FAX: (518) 452 -0511 01100 — SPECIAL REQUIREMENTS J. NEW STORE CONSTRUCTION K. wRiTTEN DAILY JOURNAL shall be maintained L TELEPHONE shall be provided on site by Tenant's Contractor. M. DESIGNATE A SUPERINTENDENT for the duration of the Project and submit his /her name to the Tenant. N. Work shall be completed in a timely manner, consistent with the approved CONSTRUCTION SCHEDULE. P. The Tenant's Contractor shall be responsible for receiving and maintaining in good condition all millwork, fixtures and equipment up to the Date of Substantial Completion. Q. All Tenant material delivered to the Project shall be checked against the Tenant's material list by the Tenant's Contractor at the time of delivery. All discrepancies shall be noted in the Receiving Report and in the Daily Journal, and the Tenant's Contractor shall immediately notify the Tenant of same. All Shortages occurring after receipt of goods shall be charged back to the Tenant's Contractor. R.CLEA N 1 N G: a. Each Subcontractor shall clean his /her Work and remove all trash, debris, packing, etc... resulting from that Work. b. Final cleaning shall be done by a professional cleaner. See specification section 01710 – FINAL CLEANING 01340 — SUBMITTALS 5. Product samples, manufacturer's data and shop drawings shall be submitted to Comprehensive Development Corp. for review prior to fabrication or start of work. 01700 — CONTRACT CLOSE —OUT T. Substantial Completion is the date certified by Tenant's Project Manager on which the Work or designated portion thereof is sufficiently complete so the Tenant may occupy the same for the intended purpose. U. Provide the following for close –out: 1 –Daily Journal 2– Operation and Maintenance Data 3 –Keys 4 –Spare Parts, Materials and Stock 5– Certificate of Inspection /Occupancy 6– Certificate of Insurance 7– Evidence of Payment and Release of Liens 8 –List of Subcontractors, Vendors and Suppliers 9 –Final Statement of Account V. Construction codes and keys must be turned into TWEC with the General Contractor's final payment request or the contractor will be charged $70. NOTE: T.G.C. TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND INFORM THE TENANT'S PROJECT MANAGER AND THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. NOTE: T.G.C. TO FIELD VERIFY CONDITION OF ALL ITEMS DESIGNATED TO REMAIN OR BE REUSED AND INFORM TENANT'S PROJECT MANAGER AT THE START OF CONSTRUCTION OF ANY ITEMS IN NEED OF REPAIR. 1 F— LLJ LLJ U) LiJ a ®a SHEET NUMBER T -1 SHEET 1 OF 17 Ter: 781-331-4000 Fax: 781-335-2115 PROJECT COORDINAllON: Il mo .IN STOCKROOM 1 (1 OCCUPANT) STOCKROOM 2 (1 occuPANT) 11 TOILET t ROOM 4 I L_ r J1 - - E MEANS OF EGRESS: OCCUPANCY SALES AREA STOCKROOM 1 STOCKROOM 2 TOTAL OCCUPANCY LOAD: 3,322 S.F. EXIT WIDTH: # OF EXITS: MAXIMUM TRAVEL DISTANCE TO EXITS: GROSS FLOOR FLOOR AREA AREA OCCUPANT 3,044 S.F. 30 S.F. 201 S.F. 300 S.F. 77 S.F. 300 S.F. REQUIRED (104 OCCUPANTS x 0.2 IN.) = 20.8 IN. 2 250 FT. (SPRINKLED) OCCUPANT LOAD 102 1 • 1 104 PROVIDED 204" 2 ±50' -0" e SALES AREA (102 OCCUPANTS) CASH WRAP (SALES AREA) L 1 1 --- REVIEWED FOR CODE COMPLIANCE APPROVE pR 2, 8 MB City Of Tukvilla BUILDING DIVISION S4J6 RECE ED CITY OF TUKWILA MAR 032008 PERMIT CENTER z (f) LiJ C5 W • Mitt lii1 1 SHEET NUMBER T 2 SHEET 2 OF 17 0 U) 0 cn w v - SURFACEMID:PAPER BOBRICK MODEL LIB -235, FURNISHED AND INSTALLED BY T.G.C. BOTTCM OF DISPENSER TO BE 39" A.F.F. 0 1!) 7 1/4" A /A -1 0 2 4 WATER FOUNTAIN, SEE PLUMBING DRAWING FOR ADDITIONAL INFORMATION ELECTRICAL EQUIPMENT, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION T.G.C. TO BOX OUT AROUND X -BEAM TO MINIMAL DIMENSIONS. MAINTAIN A MINIMUM OF 7-0' CLEAR HEIGHT FROM FLOOR SLAB. FIRE EXTINGUISHER, T.G.C. TO .VERIFY REQUIREMENTS WITH LOCAL AUTHORITIES T.G.C. TO FURNISH AND INSTALL TRANSITION STRIP AS REQUIRED NOTE T.G.C. TO REMOVE PORTION OF SERVICE CORRIDOR WALL TO 8' -0' A.F.F. AS REQUIRED TO CONSTRUCT REAR EGRESS DOOR ALCOVE. FYE SIDE (TENANT TO CORRIDOR DEMISING WALL) NOTE ONE HOUR ARE RATED PARTITION TO DECK PER U.L i9J -465, SEE DETAIL 5/N -1 EXISTING GYPSUM WALL BOARD TO DECK ABOVE BY LANDLORD T.G.C. TO INSTALL 5/8" GYPSUM WALL BOARD TYPE -X TO DECK ABOVE EXISTING METAL STUDS TO DECK ABOVE BY LANDLORD SALES AREA SIDE SLATWALL GLUED & SCREWED DIRECTLY TO FACE OF GYPSUM WALL BOARD 5/8' GYPSUM WALL BOARD TYPE -X TO 6' ABOVE ADJACENT CEILING 3 5/8' 20 GA. METAL STUD 0 16' O.C. TO 6' ABOVE ADJACENT CEILING NOTE SEE DETAIL 4/N -1 FOR ADDITIONAL INFORMATION. an D Waft, 4115 "441 I f� 1 I• v WALL ASSEMBLY Partition Schedule 16 INCHES 8 4 -6" EXIST. ASE DIMENSION 1 7 1/4" v 3 -3 1/4 S -11 1/8" ± 1 2 4 Mgr L .M ___________ ____ GYPSUM WALL BOARD BY OTHERS STOCKROOM SIDE 5/8' GYPSUM WALL BOARD TYPE -X TO 6' ABOVE ADJACENT CEILING 3 5/8" 20 GA. METAL STUD 0 16' O.C. TO 6' ABOVE ADJACENT CEILING NOTE SEE DETAIL 4/N -1 FOR ADDITIONAL INFORMATION. STOCKROOM 9 3' -0' x 6' -8' HIGH CASED OPENING, SEE DETAIL 3/A -1 3' -0' EGRESS CORRIDOR 4 O 9 3' -0' STOCKROOM ©4 9 3' -0' x 6' -8' HIGH CASED OPENING, SEE DETAIL 3/A -1 15' -6 5/8' SALES AREA Floor H FYE SIDE (TENANT TO TENANT DEMISING WALL) NOTE ONE HOUR FIRE RATED PARTITION TO ABOVE TENANT CEILING, PER U.L. 11.1-465, SEE DETAIL 6/N -1 T.G.C. TO INSTALL 5/8" GYPSUM WALL BOARD TYPE -X TO 6' MIN. CLEAR BELOW UNDER OF DECK. EXISTING METAL STUDS TO DECK ABOVE BY LANDLORD 23' -2' EXIST. NOTE: SEE SHEET N -1 FOR TOILET ROOM ACCESSORY SPECIFICATIONS. NOTE: T.G.C. TO INSTALL WATERPROOF MEMBRANE BENEATH TOILET ROOM FLOOR AND 6' UP WALLS PER LANDLORD REQUIREMENTS. TOILET ROOM ©O 6' -8" DIA. 7 -3 3/4" 7' -3 3/4" NOTE UNDERSIDE OF CORRUGATED METAL DECK IS 19' -1" A.F.F. & 20'- 11'A.F.F. STEEL BEAMS SPAN IN FRONT TO BACK AND SIDE TO SIDE. LOWEST CLEAR HEIGHT TO STRUCTURE IS 17 -9' A.F.F. THERE I5 NO SPRAY ON FIREPROOFING OTHER THAN ON COLUMNS ATTACHED TO X- BRACING. 8 FEET NOTE T.G.C. TO PATCH, REPAIR AND /OR REPLACE EXISTING GYP. BD. AS REQUIRED TO PREPARE SURFACE TO RECEIVE NEW FINISH. NOTE PROVIDE LATERAL BRACING AS REQUIRED AT ALL WALLS THAT DO NOT EXTEND TO DECK IF APPLICABLE, SEE DETAIL 4/N -1. • • N I 1n 7 1/4' Key TOILET ROOM SIDE 5/8" GYPSUM WALL BOARD TYPE -X TO 8' -0' A.F.F. 5/8" GYPSUM WALL BOARD TYPE -X TO 7' -6' A.F.F. 30' -7' EXIST. LEASE DIMENSION T.G.C. TO CORE SLAB AS REQUIRED TO INSTALL SALES AREA FIXTURE WINING. SEE SHEET E -2 FOR ADDITONAL INFORMATION. 0 OZ NOTE T.G.C. TO FURNISH AND INSTALL 5/8' TYPE -X GYPSUM BOARD ON BACK OF LANDLORD BULKHEAD TO DECK NOTE ALL WOOD USED AS BLOCKING OR SHEATHING TO BE FIRE RETARDANT, NO WOOD TO BE INSTALLED ABOVE TENANTS CEILING. DENOTES NEW WALL PAR11110N TO BE CONSTRUCTED FYE SIDE (TENANT TO CORRIDOR DEMISING WALL) NOTE ONE HOUR FIRE RATED PARTITION TO DECK PER U.L iJ -465, SEE DETAIL 5/44 -1 EXISTING GYPSUM WALL BOARD TO DECK ABOVE BY LANDLORD T.G.C. TO INSTALL 5/8" GYPSUM WALL BOARD TYPE -X TO DECK ABOVE EXISTING METAL STUDS TO DECK ABOVE BY LANDLORD SLATWALL GLUED & SCREWED DIRECTLY TO FACE OF GYPSUM WALL BOARD 3 5/8" 20 GA. METAL STUD 0 16' O.C. TO 7 -6' A.F.F. NOTE SEE SPECIFICATION 09250 -- GYPSUM DRYWALL SYSTEM ON SHEET N-1 FOR ADDITIONAL INFORMATION. NOTE T.G.C. TO F1RETAPE AND SEAL ALL EXISTING GYPSUM WALLBOARD ON DEMISING WALLS FROM FLOOR TO DECK IF NOT EXIST1NG. J _ DENOTES EXISTING WALL PAR11110N 7 1/4' GYPSUM WALL BOARD BY OTHERS T.G.C. TO INSTALL 5/8" GYPSUM WALL BOARD TYPE -X TO 6' MIN. CLEAR BELOW UNDERSIDE OF DECK. SLATWALL GLUED & SCREWED DIRECTLY TO FACE OF GYPSUM WALL BOARD EGRESS CORRIDOR 5/8' GYPSUM WALL BOARD TYPE -X TO 6' ABOVE ADJACENT CEILING 3 5/8" 20 GA. METAL STUD 0 16' O.C. TO 6' ABOVE ADJACENT CEILING NOTE SEE DETAIL 4/N -1 FOR ADDITIONAL INFORMATION. r v FYE SIDE (TENANT TO TENANT DEMISING WALL) NOTE ONE HOUR FIRE RATED PARTITION TO ABOVE TENANT CEIMNG, PER U.L fU -465, SEE DETAIL 6/N -1 EXISTING METAL STUDS TO DECK ABOVE BY LANDLORD E 30' -0" EXIST. ilk • • • Y T.G.C. TO CORE SLAB AS REQUIRED TO INSTALL SALES AREA FIXTURE WIRING. SEE SHEET E -2 FOR ADDITIONAL INFORMATION. Y FYE SIDE SLATWALL GLUED & SCREWED DIRECTLY TO FACE OF GYPSUM WALL BOARD 3 5/8" 20 GA METAL STUDS 0 16" O.C. TO 6' ABOVE ADJACENT CEUNG 5/8' GYPSUM WALL BOARD TYPE -X TO 6" ABOVE ADJACENT CEILING EGRESS CORRIDOR NOTE: ONE HOUR FIRE RATED PARTITION TO DECK PER U.L ¢U -465, SEE DETAIL 4/N -1 5/8' GYPSUM WALL BOARD TYPE -X TO DECK ABOVE 3 5/8' 20 GA. METAL STUD 0 16' O.C. TO DECK ABOVE omm e rin 107 -7' EXIST. LEASE DIMENSION STOCKROOM SIDE 5/8' GYPSUM WALL BOARD PAINT TO MATCH ADJACENT WALL FINISH C /A --1 STOCKROOM SIDE 5/8" GYPSUM WALL BOARD PAINT TO MATCH ADJACENT WALL �. FINISH C /A -1 ENCLOSE TO MINIMAL DIMENSIONS, TYP. TYP. OF 3 9 91' -1 1/2" DOOR ASSEMBLY Head Deta 0 2 4 2 4 � r DOOR ASSEMBLY Jars Deta 0 STOCKROOM SIDE 5/8" GYPSUM WALL BOARD STOCKROOM SIDE 3 Jamb Detail 1-1 0 1 2 4 8 INCHES 8 INCHES 3 5/8" METAL STUD CORRIDOR SIDE 3 5/8' METAL STUD 5/8" GYPSUM WALL BOARD CORRIDOR SIDE NOTE KD METAL FRAME CASED OPENING HEAD DETAIL I5 SIMILAR. SEE DETAIL 1/A -1 FOR HEAD FRAMING. CASED OPENING 8 INCHES 30' -0' EXIST. SALES AREA O NOTE INSTALL 6' HIGH PAINTED WOOD BASE ON AIL SALES AREA W ADJACENT TO CARPET TILE FLOOR NOTE ALL SLATWALL TO RECEIVE 3/4' x 3/4' METAL WALL ANGLES WITH SA11N NATURAL FINISH AT TOP, CORNERS AND EXPOSED ENDS SEE SHEET A -4 FOR DETAILS. NOTE SEE SHEETS A-2 AND A -3 FOR INFORMATION REGARDING WALL MOUNTED ITEMS WITHIN SALES AREA, TYP. NOTE ALL PERIMETER WALLS IN SALES AREA TO RECEIVE 3' O.C. SLATWALL FROM 6' A.F.F. TO 7 -3' A.F.F. - UNLESS OTHERWISE NOTED ON INTERIOR ELEVATIONS. PREFNISHED SLATWALL 9 9 A SALES AREA SIDE 5/8" GYPSUM WALL BOARD, SEE SHEET A -2 FOR FINISH PAINT TO MATCH ADJACENT WALL FINISH SALES AREA SIDE f SLATWALL WALL PANEL 0 3/4' x 3/4' METAL WALL ANGLE 0 WITH SATIN NATURAL FINISH 3 5/8" METAL STUD 5/8" GYPSUM WALL BOARD, SEE SHEET A -2 FOR FINISH PAINT TO MATCH ADJACENT WALL FINISH 73' -10" EXIST. LEASE DIMENSION FIRE EXTINGUISHER, T.G.C. TO VERIFY REQUIREMENTS WITH LOCAL AUTHORITI NOTE: CASHWRAP TO HAVE A MINIMUM 36" WIDE AREA A MAXI UM OF 34" A.F.F. TO COMPLY : T-I HANDICAP ACCESS1BILIT REQUIREMENTS. SEE SH F-1 01 N A/A 1 3 -4' 3 9 ONE REQUIRED -- BY T.G.C. OMIT OF SLATWALL, SEE SHEET A -2 LEASE UNE DOOR CLOSER \ Dog -ll PEEP HOLE 0 60' A.F.F. PULL HANDLE PANIC EXIT DEVICE FLOOR SWEEP ENAMEL (STOCKROOM SIDE) ® TOP OF CONCRETE EGRESS \SERVICE DOOR DOOR - Flush Metal 60 minute fire rated HARDWARE - SET B plus Wall Mounted Stop FRAME - Flush Metal KD 18 GA. Equal Rabbets 4 7/8" Jamb Depth 60 minute fire rated NOTE LANDLORD TO FURNISH AND INSTALL NEW TENANT IDENTIF1CA11ON SIGNAGE ON REAR FACE OF EGRESS DOOR. NOTE T.G.C. TO FURNISH AND INSTALL DOOR BUZZER W /ANNUNCIATOR IN STOCKROOM AND ABOVE CEIUNG AT CASHWRAP, SEE SHEET E -2 FOR ADDITIONAL INFORMATION. UNE OF SOFFIT ABOVE LIMIT OF CARPET O PEDESTAL TYPE SENSORMATIC SECURITY SYSTEM, TYP. OF 2 NE OF SOFFIT ABOVE UNE OF SOFFIT ABOVE COLUMN TO BE ENCLOSED TO MINIMAL DIMENSIONS WITH METAL STUDS AND 5/8' GYP. BD. TO 12' -6" A.F.F., TYP. OF 3. FINISH WITH 8 16 d COLUMN TO BE ENCLOSED TO SOFFIT ABOVE, SEE DETAIL ON SHEET A -1.1, FINISH WITH El 0 is 0 (0 NOTE: COORDINATE ALL WORK WITH TENANT'S PROJECT MANAGER ALL LOCKSETS TO BE LEVER TYPE HANDLES AND CONFORM TO HANDICAP ACCESSIBILITY REQUIREMENTS. 08100 - DOORS 84 FRAMES Door Schedule H i-- - --- - I 0 1 2 4 8 FEET 24' -6 1/4' EXIST. CASHWRAP SEE SHEET F -1 1 1 - 11 T.G.C. TO CORE SLAB AS REQUIRED TO INSTALL SECURITY PEDESTAL WIRING. SEE SHEET E -2 FOR ADDITIONAL INFORMATION. T.G.C. TO CORE SLAB AS REQUIRED TO INSTALL SECURITY PEDESTAL WIRING. SEE SHEET E -2 FOR ADDITIONAL INFORMATION. or■ alk 3' -4' S -0" UNIT CIF CERAM C TILE 3' —O' Et *Mil TO MATCH 3' -6' IS ig MAPLE VENEER (BOTH SIDES) PAINT FRAME TO MATCH ADJACENT WALL (BOTH SIDES) J KICKPLATE s TOP OF CONCRETE SALES /CORRIDOR DOOR ONE REQUIRED - BY T.G.C. DOOR - Flush wood, 1 -3/4" Solid Core w /Maple Veneer HARDWARE SET A plus Floor Mounted Stop FRAME - Flush Metal, KD 18 GA. Equal Rabbets 4 7/8" Jamb Depth NOTE: SEE SHEET A-1.2 FOR FLOORING FINISH PLAN AT STOREFRONT. NOTE: SEE SHEET A -1.1 FOR STOREFRONT ASSEMBLY DETAILS. NOTE APPLY SIGN TO STORE SIDE OF BOTTOM BAR OF ROLL-UP GRILLES STATING 'THIS GRILLE TO REMAIN OPEN DURING OCCUPANCY" NOTE PROVIDE FLUSH INSTALLATION AT ALL FLOOR FINISH TRANSITIONS. 1/2' TEMPERED GLAZING, SEE A -1.2 FOR ADDITIONAL INFORMATION LEASE LINE STOREFRONT GRILLE PIER, WRAP W11H T.G.C. TO INSTALL MALL FLOOR 11LE BETWEEN LEASE UNE AND GRILLE CLOSURE UNE CENTERLINE CF MANUAL ROLL -UP GRILLE SIGN CABINET ABOVE, SEE A -1.2 FOR ADDITIONAL INFORMATION LIMIT OF TENANTO CERAMIC TILE LEASE UNE Aik Tar STOREFRONT GRILLE PIER, WRAP WITH 1/2' TEMPERED GLAZING, SEE A-1.2 FOR ADDITIONAL INFORMATION CODE CoMPU APPROVED MAR 9 S „tf 4 Hardware Schedule " 3' -4" 3' -0" 2" 9 NOTE T.G.C. TO FURNISH AND INSTALL UNISEX HANDICAP ACCESSIBILITY SIGNAGE, ADJACENT TO LATCH SIDE OF DOOR 0 60" A.F.F. TO CENTERLINE PRIVACY LOCKSET WITH LEVER HANDLE ENAMEL (BOTH SIDES) S TOP OF CONCRETE TOILET ROOM DOOR ONE REQUIRED - BY T.G.C. DOOR - Flush wood, 1 -3/4" Solid Core HARDWARE - SET C plus Floor Mounted Stop FRAME - Flush Metal, KD 18 GA. Equal Rabbets 4 7/8" Jamb Depth ALL HARDWARE FINISH 626 -US26D - DULL CHROME SET k HINGES - Butt, 1 1/2 Pair • LOCK SET - Passage - Arrow, L01 -SR, Lever Type • KICK PLATE, Both Sides - Brookline stainless steel 10" x 34" • DOOR CLOSER -- Norton 8300, Stockroom Side • ALARM - Programmable PG21MS by Alarm Lock ( "Annunciate" Mode) SET B: HINGES - Butt, 1 1/2 Pair -- Tamper Proof • HARDWARE- Detex Alarm and Panic Hardware #V40XEB • DOOR CLOSER- Norton 8300, Tenant Side • PULL HANDLE - Stanley #SP482, Tenant Side • FLOOR SWEEP - Pemko 18061Cp • PEEP HOLE - Ives 698, 190' Viewer SET C: HINGES - Butt, 1 1/2 Pair • LOCK SET - Privacy - Arrow, #L02 -SR, Lever Type RECE ED CITY OF TUKVALA • = FURNISHED BY TENANT, INSTALLED BY TENANT'S CONTRACTAl o 3 2008 PERMIT CENTER m W - m ®® al a 1Y1i�1 0 CPA CIO CO o 1 . 7 g t tel 1e7 )1 ". N 00 00 S OO a N N .. a.) Cf O I_ —' 0 /� V J SHEET NUMBER A-1 SHEET 3 OF 17 • SALES AREA GYP. BD. CEILING HEIGHT 11' -10" A.F.F. SOFFIT o© o© FINISHED CEILING HEIGHT 10'-0' o© \ \ • T.G.C. TO INSTALL 5/8' TYPE -X GYP. BD. ON BACK FACE OF MALL BULKHEAD TO DECK AS REQUIRED FOR SMOKE BARRIER 0 BEYOND FINISHED FLOOR A /A - 0 BEYCND 0 SIGN SOFFIT Section L- T.G.C. TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SA11N NATURAL #020, ALL SIDES, TYP. POST BY G.C. - CONSISTING OF (2)6 "x1 5/8, 16 GA. METAL STUDS INSIDE (2)6' -16 GA. METAL TRACK EQ. \ • • \ \ \ \ \\ \\ \ • • \ 0 PAINT RETURNS T -6" 0 2 4 8 16 INCHES .444 ZA,vr% 1 LAI' 0 TENANTS SIGN CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL $020. BREAK METAL TO FILL VOID AREA BETWEEN FACE OF SOFFIT AND BACK OF SIGN CABINET. AdiO I fFl 11 EQ. EXISTING LANDLORD UGHT COVE V -0" • 3' -6' STOREFRONT ASSEMBLY Typical Detail 0 2 4 8 16 INCHES m 1 m0 • STOREFRONT PIER EQ. NOTE: SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO LANDLORD FOR APPROVAL PRIOR TO FABRICATION. NOTE: STOREFRONT FRAMING TO ATTACH TO STRUCTURE ABOVE BRACE AS REQUIRED. DO NOT ATTACH TO LANDLORD SOFFIT OR DECK. 2' -0" LEASE LINE EXISTING LANDLORD NEUTRAL PIER ALL SIDES 0 1/8' AIR SPACE. NO SILICONE AT VERTICAL 1 SEAMS, TYP. 1 -LEASE UNE 0 : 5 1/2' • • • • EQ. ©® BEYOND BEYOND LANDLORD FINISHED FLOOR AI TOP OF SIGN CABINET 15-O" A.F.F. BOTTOM OF LANDLORD UGHT COVE A.F.F. INTERNALLY ILLUMINATED LOGO SIGN, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR 31 BOTTOM REAR OF SIGN CABINET TO HAW 2' LIP FURNISHED AND INSTALLED BY TENANT'S SIGN CONTRACTOR NOTE TENANTS SIGN CONTRACTOR TO FABRICATE SKIN CABINET WITH SIDES, TOP AND BOTTOM OF .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020. FACE OF PIER BEYOND FIRST GROUT UNE TO BE 6' A.F.F. NOTE: ROLL-UP GRILLE OPENING TO BE MINIMUM 1' WIDER CN EACH SIDE THAN THE FURTHEST EXTREMITY ALONG THE BOTTOM BAR OF GRILLE CURTAIN, (TYPICALLY 6'). T.G.C. TO FELD VERIFY DIMENSION WITH ROLL-UP GRILLE INSTALLER PRIOR TO CONSTRUCTION OF SOFFIT. PROVIDE METAL GYPSUM BOARD CORNER BEAD AT OUTSIDE CORNERS. UNE OF SOFFIT ABOVE, TYP. - ()ALL 4 SIDES ALL 4 SIDES ©© 0 1n T -6" SOFFIT FINISHED CEILING HEIGHT Q!!) 11' -10' A.F.F. LINE OF GLAZING TRANSOM ABOVE POST BY G.C. - CONSISTING OF (2)6 "x1 5/8, 16 GA. METAL STUDS INSIDE (2)6' -16 GA. METAL TRACK 0 3' -6" CENTERLINE OF ROLL-UP GRILLE FACE OF SOFFIT ABOVE 2' -0' o© 3' T.G.C. TO INSTALL 5/8" TYPE -X GYP. BD. ON BACK FACE OF MALL BULKHEAD TO DECK AS REQUIRED FOR SMOKE BARRIER STOREFRONT ASSEMBLY Typical Detail 1 0 2 4 16 INCHES 7 1/2" •\ \• 4' 0 \ • •\ \ \ \ \ \ \ \ \ • \ • • \ T.G.C. TO FURNISH AND INSTALL 040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020 LEASE UNE 0 0 0 0 1 EQ. FINISHED FLOOR o© STOREFRONT GLAZING EQ. ti 1' -4' BREAK METAL FINISH ti LEASE LINE 1/8' AIR SPACE, NO SIUCCNE AT VERTICAL SEAMS, Tr. Section 1 0 2 4 8 16 INCHES O ALL 4 SIDES OE ALL 4 SIDES UNE OF SOFFIT ABOVE, TYP. - m 7 A /A - " 0 TOP OF STOREFRONT Air 15-0' A.F.F. VIP 14' -6' A.F.F. \ BOTTOM OF TRANSOM FRAMING 10' -1 7/8" A.F.F. FACE OF PER BEYOND BREAK METAL BAS U$ LANDLORD FINISHED FLOOR NOTE: STOREFRONT FRAMING TO ATTACH TO STRUCTURE ABOVE. BRACE AS REQUIRED. DO NOT ATTACH TO LANDLORD SOFFIT OR DECK 1' -6" CENTERLINE OF ROLL - UP GRILLE - 1 EXISTING COLUMN ti EXISTING LANDLORD LIGHT COVE T.G.C. TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL 1020 BOTTOM OF LANDLORD LIGHT COVE UNDERSIDE OF SOFFIT/ S TOP OF GLAZING CHANEL 13' -10 1/4' A.F.F. 6' HIGH NATURAL ALUMINUM BAFFLE FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR 13 mm BLUE NEON FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR SEE SHEET A -3 T.G.C. TO FURNISH AND INSTALL .040 BREAK METAL ON ALL SIDES OF GLAZING TRANSOM TO MATCH STYLMARK SATIN NATURAL #020 3' -6" 0 POST BY G.C. - CONSISTING OF (2)6"x1 5/8, 16 GA. i METAL STUDS INSIDE (2)6 " -16 GA. METAL TRACK -I LINE OF GLAZING TRANSOM ABOVE STOREFRONT ASSEMBLY Typical Detail F--i 1 0 2 4 8 16 INCHES FACE OF SOFFIT ABOVE 7 1/2' o © 0 LEASE UNE 0 1/8' AIR SPACE, NO SILICONE AT VERTICAL SEAMS, TYP. 2' • 2" STOREFRONT ASSEMBLY Typical Detail H Ii 1 0 1 2 4 8 INCHES EXISTING LANDLORD LIGHT COVE T.G.C. TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020 6; TOP OF STOREFRONT 15-0" A.F.F. T.G.C. TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020 UNDERSIDE OF SOFFIT/ TOP OF GLAZING CHANNEL A.F.F. RETURN BREAK METAL TO GLAZING CHANNEL STOREFRONT ASSEMBLY Typical Detail H I—� 1 0 1 2 4 8 INCHES • POST BY G.C. - CONSISTING OF (2)6'x1 5/8, 16 GA. METAL STUDS INSIDE (2)6' -16 GA. METAL TRACK T.G.C. TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL 1020 A /A -1 Note Key STOREFRONT ASSEMBLY T -4' 8 Typical Detail 0 2 4 8 16 INCHES 10 5/8" Fire Code Sheetrock N/A 0 3/4" Fire Retardant M.D.F. Board 03 26 3/8" x 13" x 3/8" Ceramic Tile ® 3 5/8" Metal Stud (20 Ga. Minimum at 16" O.C.) ® Suspended Gypsum Board Ceiling System With Hang Wire CAD 4'—O" O.C. Each Way Suspend From Structure Above ® Existing Framing O Existing Gypsum Board ® 1/2" Tempered Glazing — See Specification 08410 on Sheet N -1 1/8" Air Space At Vertical Joints — No Silicone Typ. ® 6" High x 2" Wide Glazing Channel with Anchor 10 1 3/4" High x 2" Wide Glazing Channel O 2-1/2" Metal Track N/A 12 3" X 3" X 3/8" ANGLE 13 Slatwall 14 Wood Blocking (Fire Retardant) 15 Neoprene Gasket 16 3/4" x 3/4" Slatwall Trim 17 3 5/8" Metal Track 18 6" Metal Stud at 16" O.C. (20 GA. Minimum) 19 3" X 3" Metal Grille Tube (or as sized per grille supplier) • Manual Roll —up Grille N/A 21 1/2" x 1/2" x 1/8" U-- Channel with Black Anodized Finish N/A Q2 Metal Feature Strip with Brushed Metal Finish See Specifications on Sheet A -2 © Glazing Vinyl, Inside and Outside — See Specifications on Sheet N -1 ® 2 1/2" Metal Stud (20 Ga. Minimum at 16" O.C.) @ 3/4" x 3/4" x 1/8" U— Channel with Black Anodized Finish © Down Light beyond ® Existing Landlord Neutral Pier & finish to remain. N/A Q 6" High Mall Tile Base N/A ® 8" Metal Stud (16GA. Min.) N/A ® Corner Bead 0 Storefront Sign Fumished and Installed by Tenant's Sign Contractor ® 6" Metal Track REVIEWED �NCE CODE APPIROVED MAR 2 S 7in Cif Ofi Tukwila BUILDING DIVISION [LEASE UNE 0 9 0 1/8' AIR SPACE, NO SILICONE AT VERTICAL i SEAMS, TYP. 01 ALL SIDES T.G.C. TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020 LEASE UNE EXISTING LANDLORD NEUTRAL PIER RECE: "ED CITY OF TUKVAL A NAP 0 3 2008 PERMIT CENTER z Q\ SHEET NUMBER A -1.1 SHEET 3 OF 17 • • = =4 = = c 0 NOTE SEE DETAILS ON SHEET A -1.1 FOR ADDITIONAL INFORMATION. TRANSOM TO POST CONNECTION Typical Detail H 1 2 4 8 INCHES 60" HIGH x 14' -0" LONG x 8" DEEP, INTERNALLY ILLUMINATED SIGN CABINET, FURNISHED AND INSTALLED BY THE TENANTS SIGN CONTRACTOR. SEE CABINET SPECIFICATIONS THIS SHEET FOR ADDITIONAL INFORMATION. TENANTS GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL ¢020. BOX BEAM CONSISTING OF (2)8"x1 5/8" -16 GA. METAL STUDS RUNNING HORIZONTALLY INSIDE (W-16 GA METAL TRACKS, TOP AND BOTTOM. 6' HIGH METAL BASE. 6" HIGH SATIN NATURAL GLAZING CHANNEL, TYP. POST BY G.C. - CONSISTING OF (2)6 1 x1 5/8-16 GA. METAL STUDS INSIDE (2)6' -16 GA. METAL TRACKS (3) 112 -14 EACH LEG (5) #12 -14 TO POST 8' -16 GA. METAL TRACK 7 1/4' 2' -6 "± .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020 FURNISHED AND INSTALLED BY TENANTS GENERAL CONTRACTOR S BOTTOM OF TRANSOM FRAMING 10' -1 7/8" A.F.F. 5/8' GYPSUM WALL BOARD TYPE -X 2' -0' E 1" W10E X 2' HIGH HEADER CHANNEL (STYLMARK PART# 110360) NOTE T.G.C. TO FURNISH AND INSTALL 3/4' X 3/4' BLACK ANODIZED METAL U- CHANNEL AT SIDES AND TOP OF STOREFRONT. NOTE SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO TENANT AND LANDLORD FOR APPROVAL PRIOR TO FABRICATION. Storefront Elevation 0 5 1 2 1 FEET FINISHED GYP. BD. 7 1/2" GLAZING TRANSOM Typical Detail H I- -----i I 0 1 2 4 8 INCHES 0 CABINET SGN SPECIFICATIONS: INTERNALLY Ili_UMINATED SIGN CABINET TO HAVE SATIN ALUMINUM FACE WITH DUSTED CRYSTAL SVARLS, 3/4' PUSH-THRU 42' HIGH 'Eye" LOGO (19' HIGH LETTERS), r HIGH, H -THRU 'for your entertainment" ORANGE LETTERS AND 8' HIGH, PUSH -THRU SIDES, 'music movies' BLUE LETTERS. EXPOSED TOP AND BOTTOM OF SIGN CABINET ALSO TO BE SATIN M. El 13" x 26 3/8" CERAMIC 1ILE WITH FIRST GROUT LINE AT 6" A.F.F. 14' -0" ROLL UP GRILLE OPENING FACE OF ROLL -UP GRILLE PIER 1/2' TEMPERED GLAZING 1" WE X 1" HIGH BOTTOM CHANNEL (STYLMARK PART# 110361) .040 BREAK METAL TO MATCH ST NAARK SATIN NATURAL #020, WITH HEMMED EDGE, FURNISHED AND INSTALLED BY TENANTS GENERAL CONTRACTOR BOX BEAM CONSISTING OF (2) 8'x1 5/8' -16 GA. METAL STUDS RUNNING HORIZONTALLY INSIDE (2) 6' -16 GA. METAL TRACKS, TOP AND BOTTOM. 5/8" GYPSUM WALL BOARD TYPE --X S BOTTOM OF TRANSOM BREAK METAL 10' --0' A.F.F. BREAK METAL WITH HEMMED EDGE TO EXTEND 1 -1/4' BELOW TRANSOM GYP. BD. 1/2" TEMPERED GLAZING FACE OF 6' HIGH GLAZING CHANNEL AT FLOOR 35-0" EXIST. LEASE DIMENSION 2' -0" 12' -3 "± " 6' -6' 7 1/4' 3' -6" TENANT'S GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020. 6" HIGH METAL BASE. 6" HIGH SATIN NATURAL GLAZING CHANNEL, TYP. Doo,// T.G.C. TO INSTALL MALL FLOOR 111E BETWEEN LEASE LINE AND CENTERLNE OF ROLL -UP GRILLE CENTERLINE OF ROLL-LP GRILLE LEASE LINE ti CC 0 kt- a 0 EXTENT OF CARPET 111E O REVIEWED E CODE COMPLIANCE APPROVED MAR x;305 City Tukwila WILDING Drii$.1(-14 ALIGN EDGE OF TILE FLOORING YITH CORNER OF GRILLE PIER, TYP. RECE+ "V3 CITY OF TUR4'ALA MAP 0 3LOUO PERMIT CENTER J 0 U z l ateen IYI■■I r SHEET NUMBER A -1.2 SHEET 5 OF 17 Tel: 781-331-4000 Fax: 781-335-2115 JOB NO:PY-06-01-1, STORE NO: 1246 DATE: 21201013 CHECKED: CM 1 EXTENT OF CARPET 111E * A 1* **N • ,, / I d ..., i 0 � 04 a Q T O t a u ■ i e mt. M i SOFFIT BEYOND WITH VOLTARC SPARKLING BLUE NEON AND NATURAL ALUMINUM BAFFLE, FURNISHED AND INSTALLED BY AI . r 4 3' -6" / / / Allah S -6" 5-6' - / / / / f 1 1 1 SOFFIT BEYOND WITH VOLTARC NATURAL ALUMINUM BAFFLE. FURNISHED AND INSTALLED BY M TENANTS SIGN CONTRACTOR [Y 1/2' TEMPERED GLAZING TYP. TENANT'S SIGN CONTRACTOR 1 I O O O e n e ■ a n � a _ 1 J NV 1/2" TEMPERED GLAZING Tr. o o BOTTOM OF GLAZING TRANSOM _ music • mo v. M1 /t O I. - BOTTOM OF SOFFIT EYOND GLAZING '''''.\\. BOTTOM OF GLAZING TRANSOM 13' -1O 1/4" TENANT'S GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STY AARK SA11N NATURAL / /' .O -,O I. \ / \ BOTTOM OF ENTRANCE SOFFIT /. i i N. ` '. i - F ' � f ,''� / ROLL UP GRILLE OPENING N. .- i , � ` , ' ` I TENANTS GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020. 1/2" TEMPERED GLAZING TYP. 1020. 3/4' x 3/4' BLACK METAL U- CHANNEL i 3/4' 3/4' BLACK METAL U- CHANNEL IMI a REVEAL AT TOP AND SIDES OF STOREFRONT a a 1/2' TEMPERED GLAZING TYP. I x REVEAL AT TOP AND SIDES OF STOREFRONT PROFILE OF CASHWRAP BEYOND GLAZING o 1 CD GLAZING CLIPS 5' -0' A.F.F TO CENTERLINE C C u - L____ EQ. EQ. i 1 1 EXISTING MALL NEUTRAL PIER 'EYE" BESTING MALL NEUTRAL PIER 0 3' HIGH FROSTED WHITE VINYL "EYE" LOGO MOUNTED TO INSIDE FACE OF 1 1 3' HIGH FROSTED WHITE VINYL 10G0 MOUNTED TO INSIDE FACE OF GLAZING 0 36" A.F.F. TO CENTERLINE LEASE UNE GLAZING 0 36' A.F.F. TO CENTERLINE, LINE ' i i N I LEASE a . / • • = =4 = = c 0 NOTE SEE DETAILS ON SHEET A -1.1 FOR ADDITIONAL INFORMATION. TRANSOM TO POST CONNECTION Typical Detail H 1 2 4 8 INCHES 60" HIGH x 14' -0" LONG x 8" DEEP, INTERNALLY ILLUMINATED SIGN CABINET, FURNISHED AND INSTALLED BY THE TENANTS SIGN CONTRACTOR. SEE CABINET SPECIFICATIONS THIS SHEET FOR ADDITIONAL INFORMATION. TENANTS GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL ¢020. BOX BEAM CONSISTING OF (2)8"x1 5/8" -16 GA. METAL STUDS RUNNING HORIZONTALLY INSIDE (W-16 GA METAL TRACKS, TOP AND BOTTOM. 6' HIGH METAL BASE. 6" HIGH SATIN NATURAL GLAZING CHANNEL, TYP. POST BY G.C. - CONSISTING OF (2)6 1 x1 5/8-16 GA. METAL STUDS INSIDE (2)6' -16 GA. METAL TRACKS (3) 112 -14 EACH LEG (5) #12 -14 TO POST 8' -16 GA. METAL TRACK 7 1/4' 2' -6 "± .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020 FURNISHED AND INSTALLED BY TENANTS GENERAL CONTRACTOR S BOTTOM OF TRANSOM FRAMING 10' -1 7/8" A.F.F. 5/8' GYPSUM WALL BOARD TYPE -X 2' -0' E 1" W10E X 2' HIGH HEADER CHANNEL (STYLMARK PART# 110360) NOTE T.G.C. TO FURNISH AND INSTALL 3/4' X 3/4' BLACK ANODIZED METAL U- CHANNEL AT SIDES AND TOP OF STOREFRONT. NOTE SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO TENANT AND LANDLORD FOR APPROVAL PRIOR TO FABRICATION. Storefront Elevation 0 5 1 2 1 FEET FINISHED GYP. BD. 7 1/2" GLAZING TRANSOM Typical Detail H I- -----i I 0 1 2 4 8 INCHES 0 CABINET SGN SPECIFICATIONS: INTERNALLY Ili_UMINATED SIGN CABINET TO HAVE SATIN ALUMINUM FACE WITH DUSTED CRYSTAL SVARLS, 3/4' PUSH-THRU 42' HIGH 'Eye" LOGO (19' HIGH LETTERS), r HIGH, H -THRU 'for your entertainment" ORANGE LETTERS AND 8' HIGH, PUSH -THRU SIDES, 'music movies' BLUE LETTERS. EXPOSED TOP AND BOTTOM OF SIGN CABINET ALSO TO BE SATIN M. El 13" x 26 3/8" CERAMIC 1ILE WITH FIRST GROUT LINE AT 6" A.F.F. 14' -0" ROLL UP GRILLE OPENING FACE OF ROLL -UP GRILLE PIER 1/2' TEMPERED GLAZING 1" WE X 1" HIGH BOTTOM CHANNEL (STYLMARK PART# 110361) .040 BREAK METAL TO MATCH ST NAARK SATIN NATURAL #020, WITH HEMMED EDGE, FURNISHED AND INSTALLED BY TENANTS GENERAL CONTRACTOR BOX BEAM CONSISTING OF (2) 8'x1 5/8' -16 GA. METAL STUDS RUNNING HORIZONTALLY INSIDE (2) 6' -16 GA. METAL TRACKS, TOP AND BOTTOM. 5/8" GYPSUM WALL BOARD TYPE --X S BOTTOM OF TRANSOM BREAK METAL 10' --0' A.F.F. BREAK METAL WITH HEMMED EDGE TO EXTEND 1 -1/4' BELOW TRANSOM GYP. BD. 1/2" TEMPERED GLAZING FACE OF 6' HIGH GLAZING CHANNEL AT FLOOR 35-0" EXIST. LEASE DIMENSION 2' -0" 12' -3 "± " 6' -6' 7 1/4' 3' -6" TENANT'S GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020. 6" HIGH METAL BASE. 6" HIGH SATIN NATURAL GLAZING CHANNEL, TYP. Doo,// T.G.C. TO INSTALL MALL FLOOR 111E BETWEEN LEASE LINE AND CENTERLNE OF ROLL -UP GRILLE CENTERLINE OF ROLL-LP GRILLE LEASE LINE ti CC 0 kt- a 0 EXTENT OF CARPET 111E O REVIEWED E CODE COMPLIANCE APPROVED MAR x;305 City Tukwila WILDING Drii$.1(-14 ALIGN EDGE OF TILE FLOORING YITH CORNER OF GRILLE PIER, TYP. RECE+ "V3 CITY OF TUR4'ALA MAP 0 3LOUO PERMIT CENTER J 0 U z l ateen IYI■■I r SHEET NUMBER A -1.2 SHEET 5 OF 17 Tel: 781-331-4000 Fax: 781-335-2115 JOB NO:PY-06-01-1, STORE NO: 1246 DATE: 21201013 CHECKED: CM O EXTENT OF CARPET 111E * A 1* **N • ,, 0 � 04 a k iiiiihn • AI . r 4 3' -6" cn w re y S -6" 5-6' 1' -6" • • = =4 = = c 0 NOTE SEE DETAILS ON SHEET A -1.1 FOR ADDITIONAL INFORMATION. TRANSOM TO POST CONNECTION Typical Detail H 1 2 4 8 INCHES 60" HIGH x 14' -0" LONG x 8" DEEP, INTERNALLY ILLUMINATED SIGN CABINET, FURNISHED AND INSTALLED BY THE TENANTS SIGN CONTRACTOR. SEE CABINET SPECIFICATIONS THIS SHEET FOR ADDITIONAL INFORMATION. TENANTS GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL ¢020. BOX BEAM CONSISTING OF (2)8"x1 5/8" -16 GA. METAL STUDS RUNNING HORIZONTALLY INSIDE (W-16 GA METAL TRACKS, TOP AND BOTTOM. 6' HIGH METAL BASE. 6" HIGH SATIN NATURAL GLAZING CHANNEL, TYP. POST BY G.C. - CONSISTING OF (2)6 1 x1 5/8-16 GA. METAL STUDS INSIDE (2)6' -16 GA. METAL TRACKS (3) 112 -14 EACH LEG (5) #12 -14 TO POST 8' -16 GA. METAL TRACK 7 1/4' 2' -6 "± .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020 FURNISHED AND INSTALLED BY TENANTS GENERAL CONTRACTOR S BOTTOM OF TRANSOM FRAMING 10' -1 7/8" A.F.F. 5/8' GYPSUM WALL BOARD TYPE -X 2' -0' E 1" W10E X 2' HIGH HEADER CHANNEL (STYLMARK PART# 110360) NOTE T.G.C. TO FURNISH AND INSTALL 3/4' X 3/4' BLACK ANODIZED METAL U- CHANNEL AT SIDES AND TOP OF STOREFRONT. NOTE SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO TENANT AND LANDLORD FOR APPROVAL PRIOR TO FABRICATION. Storefront Elevation 0 5 1 2 1 FEET FINISHED GYP. BD. 7 1/2" GLAZING TRANSOM Typical Detail H I- -----i I 0 1 2 4 8 INCHES 0 CABINET SGN SPECIFICATIONS: INTERNALLY Ili_UMINATED SIGN CABINET TO HAVE SATIN ALUMINUM FACE WITH DUSTED CRYSTAL SVARLS, 3/4' PUSH-THRU 42' HIGH 'Eye" LOGO (19' HIGH LETTERS), r HIGH, H -THRU 'for your entertainment" ORANGE LETTERS AND 8' HIGH, PUSH -THRU SIDES, 'music movies' BLUE LETTERS. EXPOSED TOP AND BOTTOM OF SIGN CABINET ALSO TO BE SATIN M. El 13" x 26 3/8" CERAMIC 1ILE WITH FIRST GROUT LINE AT 6" A.F.F. 14' -0" ROLL UP GRILLE OPENING FACE OF ROLL -UP GRILLE PIER 1/2' TEMPERED GLAZING 1" WE X 1" HIGH BOTTOM CHANNEL (STYLMARK PART# 110361) .040 BREAK METAL TO MATCH ST NAARK SATIN NATURAL #020, WITH HEMMED EDGE, FURNISHED AND INSTALLED BY TENANTS GENERAL CONTRACTOR BOX BEAM CONSISTING OF (2) 8'x1 5/8' -16 GA. METAL STUDS RUNNING HORIZONTALLY INSIDE (2) 6' -16 GA. METAL TRACKS, TOP AND BOTTOM. 5/8" GYPSUM WALL BOARD TYPE --X S BOTTOM OF TRANSOM BREAK METAL 10' --0' A.F.F. BREAK METAL WITH HEMMED EDGE TO EXTEND 1 -1/4' BELOW TRANSOM GYP. BD. 1/2" TEMPERED GLAZING FACE OF 6' HIGH GLAZING CHANNEL AT FLOOR 35-0" EXIST. LEASE DIMENSION 2' -0" 12' -3 "± " 6' -6' 7 1/4' 3' -6" TENANT'S GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL #020. 6" HIGH METAL BASE. 6" HIGH SATIN NATURAL GLAZING CHANNEL, TYP. Doo,// T.G.C. TO INSTALL MALL FLOOR 111E BETWEEN LEASE LINE AND CENTERLNE OF ROLL -UP GRILLE CENTERLINE OF ROLL-LP GRILLE LEASE LINE ti CC 0 kt- a 0 EXTENT OF CARPET 111E O REVIEWED E CODE COMPLIANCE APPROVED MAR x;305 City Tukwila WILDING Drii$.1(-14 ALIGN EDGE OF TILE FLOORING YITH CORNER OF GRILLE PIER, TYP. RECE+ "V3 CITY OF TUR4'ALA MAP 0 3LOUO PERMIT CENTER J 0 U z l ateen IYI■■I r SHEET NUMBER A -1.2 SHEET 5 OF 17 Tel: 781-331-4000 Fax: 781-335-2115 JOB NO:PY-06-01-1, STORE NO: 1246 DATE: 21201013 CHECKED: CM 18' -3 1/2" ± 16' -0 3/4" ± EQ. 22-0' EQ. 5 MATERIAL/ S r - ,I STYLE/ COLOR L LOCATION r GRAPHIC 21 3s" _ 2132 -60 M 23' Sales Area m .0 -,5L 3A00 1H0l1 11VPi JO K011.09 EQ. 3' -0" 3' -0' EQ. EQ. 3' -0' 3' -0' EQ. 3' -0" 2-6' 11' -0" 2' -6' 10 Satin Finish M -6' EXTENT OF GYP. BD. CEILING - SEE SHEET A -3 1r ,£ -,L 1' 1SIX3 13NNVH3 ONIZV19 JO d01 / 111103 30 ViaL108 09900 P - TYP TYP. , Orange S .--, TYP TYP. Satin Finish M TYP. TYP. Blossom S y 8 0 5 PAINT B SOFFIT a, z OI' Blue S Sales Area Satin Finish M Moore E Eyes S See Note 1 Bek 9 0 09900 P PAINT B Benjamin R Ready W White S Stockroom, Toile Eggshell Finish M Moore M Mix E Egress Corridor 10 0 09900 P _ BOTTOM OF SOFFIT 13' -10 1/4. 1/2" TEMPERED GLAZING, TYP. 2132 -70 M Mineral Eggshell Finish M Moore I Ice 36' GIC 11 0 09900 P 36" IC Benjamin R Ready B 36' GRAPHIC Roll —up Grille RI Flat Finish M Moore M 36" GRAPHIC See Note 1 Bel( 36" GRAPHIC 06240 D DISPLAWALL M Marlite D DW707 R Rock S Slatwall w /Alum e;IIc 09900 P PAINT B Benjamin R Ready B GRAPHIC Wood Base a Satin Enamel M Moore M Mix ►n 0 < , , . — I I I - BOTTOM OF GLAZING TRANSOM 11' -10 1/4" 5 g 5 4 7 EQ. 3 �_ /4 " EQ. 21 21 ® 21 V f ye w U it .£ -,L 130 V3IY S31VS / 1 Cl \ o � 11VMLV1S JO d01 0 : E M I6Iw . : �� fir• 1/2' TEMPERED GLAZING, TYP. 0 NATURAL BREAK METAL, SEE SHEET A -1.1 FOR I ADDITIONAL INFORMATION I 6" HIGH SATIN NATURAL if CHANNEL 19 - I ' 1 " ® v ; I; ' , �! ~ ! rrrrr' F o a 8 ¢ \ _ \ 8 -1 immormo �I o o ■ _ _. r M PLAN C 5 MATERIAL/ S r - ,I STYLE/ COLOR L LOCATION GRAPHIC 21 3s" Benjamin 2 2132 -60 M Metallic S Sales Area 5 0 .o -,Z L _ TIVMJ.V1S 40 dal Moore S Silver S See Note 1 Bek 6 0 M 11.1.1 419 Benjamin 2 2134 -30 I Iron 10 Satin Finish M Moore M 1r ,£ -,L 1' 7 0 09900 P PAINT B Benjamin 2 2168 -30 O Orange S Sales Area Satin Finish M Moore B Blossom S See Note 1 Bek 8 0 09900 P PAINT B Benjamin 2 2064 -30 O OI' Blue S Sales Area PLAN C CSI M MATERIAL/ S MFR. C STYLE/ COLOR L LOCATION 09900 P PAINT B Benjamin 2 2132 -60 M Metallic S Sales Area 5 0 Satin Finish M Moore S Silver S See Note 1 Bek 6 0 09900 P PAINT B Benjamin 2 2134 -30 I Iron Satin Finish M Moore M Mountain 7 0 09900 P PAINT B Benjamin 2 2168 -30 O Orange S Sales Area Satin Finish M Moore B Blossom S See Note 1 Bek 8 0 09900 P PAINT B Benjamin 2 2064 -30 O OI' Blue S Sales Area Satin Finish M Moore E Eyes S See Note 1 Bek 9 0 09900 P PAINT B Benjamin R Ready W White S Stockroom, Toile Eggshell Finish M Moore M Mix E Egress Corridor 10 0 09900 P PAINT B Benjamin 2 2132 -70 M Mineral Eggshell Finish M Moore I Ice 11 0 09900 P PAINT B Benjamin R Ready B Black R Roll —up Grille RI Flat Finish M Moore M Mix S See Note 1 Bel( oci 0 06240 D DISPLAWALL M Marlite D DW707 R Rock S Slatwall w /Alum 13 0 09900 P PAINT B Benjamin R Ready B Black W Wood Base Satin Enamel M Moore M Mix ►n 0 06240 M MELAMINE U Uniboard 9 961 S Stainless P Prefinished Fixtu 1- G cn w m EXIT FIXTURE TO BE WALL MOUNTED, CENTERED ABOVE DOOR AT T - A.F.F. TO CENTERLINE OF FIXTURE PROFILE OF COLUMN IN FOREGROUND, SEE DETAIL 15/A -4 0 0 m 0 cn a T.G.C. TO PAINT FACE OF SOFFIT EXISTING MALL LIGHT COVE 1/2" TEMPERED GLAZING, TYP. 1/2' TEMPERED GLAZING, TYP. SATIN NATURAL BREAK METAL, SEE SHEET A -1.1 FOR ADDITIONAL INFORMATION 6" HIGH SATIN NATURAL GLAZING CHANNEL 6' HIGH METAL BASE OU 2 4 2 4 " Interior Elevation 8 FEET 36' GRAPHIC Interior Elevation 8 FEET TOILET ROOM Interior Elevation 8 FEET 2-6' SOFFIT W/VOLTARC SPARKLING BLUE NEON AND NATURAL ALUMINUM BAFFLE, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. SEE B /A -1.1 FOR ADDITIONAL INFORMATION EXTENT OF GYP. BD. CEIUNG - SEE SHEET A -3 3' -0" TYP. 36' GRAPHIC El 0 , -.. 16' -6' W--6" 2-6" 3' O.C., TYP. BUTT JOINTS TYP. SOAP DISPENSER PAPER TOWEL DISPENSER i 3' -0" 6" 36' x 36" GRAPHIC PANEL. W /3" ACRILEX FRAME, FURNISHED BY TENANT AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT LOCATION WITH TENANTS PROJECT MANAGER PRIOR TO INSTALLATION, TYP. 12' -0' b TV 0 DVD EE 7 -6" HOLD 2-6" PREFINISHED SLATWALL PANELS PREFINISHED SLATWALL PANELS / 3' O.C., TYP. BUTT JOINTS TYP. 36" x 36" GRAPHIC PANEL W /3' ACRILEX FRAME, FURNISHED BY TENANT AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT LOCATION WITH TENANTS PROJECT MANAGER PRIOR TO INSTALLATION, TYP. 14" HIGH, 1" THICK SINTRA LETTERS, MOUNTED TO ALUMINUM BAR, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR CENTER VERTICALLY ON FACE OF WALL 36' GRAPHIC Ell 1 3' 3' -0" 2T -0" _ ll Q 1 '7 3'-0' TOILET ROOM Interior Elevation H 1 2 4 8 FEET 14" & 10' HIGH, 1' THICK SINTRA LETTERS, MOUNTED TO ALUMINUM BAR, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. CENTER VERTICALLY ON FACE OF WALL 2 , -6 ' El M 2'--6" 2-6' 18 INSULATE DRAIN PIPE AS INDICATED ON PLUMBING SPECIFICATIONS 6' -8' HOLD 3' -0" TYP. 36' GRAPHIC El PAINT TRANSITION UNE a I 2'-6' TOILET ROOM AA (ii i is\ Interior Elevation � 0 1 2 4 8 E 0 1 2 4 8 T 21' -6" 5' -6" SPORTS 8 1/2' HIGH, 1' THICK SINTRA LETTERS, MOUNTED TO ALUMINUM BAR, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. CENTER VERTICALLY ON FACE OF WALL 2-6" PROFILE OF COLUMN IN FOREGROUND, SEE DETAIL 15/A -4 36" GRAPHIC El PAINT TRANSITION LINE 14" HIGH. 1' THICK SINTRA LETTERS, MOUNTED TO ALUMINUM BAR, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. CENTER VERTICALLY ON FACE OF WALL 6 _1 7' -6' HOLD TOILET ROOM Interior Elevation I—I 2 2' -6' d d U' 0 0 1 CV 0 I 0 z N 0 0 EQUAL 1 1/2" TEMPERED GLAZNG, TYP. PROFILE OF CASHWRAP 3' HIGH FROSTED VIiITE VINYL 'EYE' LOGO MOUNTED TO INSIDE FACE OF GLAZING 0 36' A.F.F. TO CENTERLINE 6' HIGH METAL BASE 6" HIGH 5A11N NATURAL GLAZING CHANNEL 4 8 FEET 3' -0" TIP. 36' GRAPHIC El 3' O.C., TYP. r 20' -O' 2' -6" BUTT JOINTS TIP. 36' x 36' GRAPHIC PANEL W /3" ACRILEX FRAME, FURNISHED BY TENANT AND INSTALLED BY GENERAL CONTRACTOR COORDINATE EXACT LOCATION WITH TENANTS PROJECT MANAGER PRIOR TO INSTALLATION, TIP. 36' GRAPHIC PREFINISHED SLATWALL PANELS TENANTS GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL p20, SEE DETAIL 3/A -1.2 AND SHEET A -1.1 FOR ADDITIONAL INFORMATION NOTE INSTALL FIRE RETARDANT WOOD BLOCKING IN WALLS AS REQUIRED TO SECURE TOILET ROOM ACCESSORIES. NOTE: THE FLUSH HANDLE ON THE WATER CLOSET SHALL BE ON THE OPEN SIDE OF THE TOILET. NOTE SEE SPECIFICATION 10810 ON SHEET N -1 FOR TOILET ROOM ACCESSORIES, ALL TOILET ROOM ACCESSORIES TO BE INSTALLED PER APPLICABLE ACCESSIBILITY REGULATIONS AND ADA GUIDELINES. NOTE: T.G.C. TO INSTALL WATERPROOF MEMBRANE AT TOILET ROOM FLOOR AND 6' LIP WALLS PER LANDLORD REQUIREMENTS. PAINT TRANSITION UNE 12-3 1/8"± SILVER VINYL 'SWAG' GRAPHICS FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR TIP. NON - ILLUMINATED CASHWRAP GRAPHIC PANELS TO BE FURNISHED BY TENANT AND INSTALLED BY THE GENERAL CONTRACTOR. PANELS TO BE CENTERED ON WALL SURFACE AT BACKWRAP. COORDINATE EXACT LOCATION WITH TENANTS PROJECT MANAGER PRIOR TO INSTALLATION, TYP. OF 3 PROFILE OF BACKWRAP ALIGN END OF SLATWALL VNTH EDGE OF BACKWRAP EQUAL 7 PROFILE OF COLUMN DRINKING WATER FOUNTAIN EQ. SURFACE MID. PAPER CUP DISPENSER, BOBRICK MODEL 15 -235, FURNISHED AND INSTALLED BY T.G.C. BOTTOM OF DISPENSER TO BE 39' A.F.F. 2-0" HOLD S -0" 36' GRAPHIC IN FOREGROUND, SEE DETAIL 15/A -4 3' -O' ! EXIT FIXTURE TO BE WALL MOUNTED, 1 1 CENTERED ABOVE GRILLE OPENING 30'X48'MIN. CLEAR FLOOR AREA AT FOUNTAIN I' MANUAL ROLL UP • GRILLE OPENING 13' x 26 3/8' CERAMIC TILE WITH FIRST GROUT LINE AT 6' A.F.F. 14' -0' HOLD 1 -3" NOTE SEE SHEET N -1 FOR TOILET ROOM ACCESSORY SPECIFICATIONS. EXISTING MALL IGHT COVE 6' SOFFTT RC SPARKLING BLUE NEON AND NATURAL SIGN E, FURNISHED AND INSTALLED BY TENANT'S R. SEE B /A -1.1 FOR ADDITIONAL INFORMATION 6' HIGH METAL BASED 2-0" HOLD EQ. Doo TENANTS GENERAL CONTRACTOR TO FURNISH AND INSTALL .040 BREAK METAL TO MATCH STYLMARK SATIN NATURAL 1020, SEE DETAIL 3/A -1.2 AND SHEET A -1.1 FOR ADDITIONAL INFORMATION '-5 5/8"± 3' -4" 6' HIGH METAL BASE 0 0 0 w m H 6" HIGH SA11N NATURAL GLAZING CHANNEL N/A N/A N/A N/A :i: Key to Interior Elevations SCHEDULE OF WALL AND FASCIA FINISHES NOTE 1: ALL METAL SURFACES TO RECEIVE LATEX ENAMEL BASED PAINT. FLOOR FINISHES PLAN CSI MATERIAL/ KEY SEC11ON DESCRIPTION cpp N PO N <§> N/A 0. Indicates NOTE 1: NOTE 2: NOTE 3: NOTE 4: Key to Finishes MFR. Tenant shall furnish materials and STYLE/ CAT. NO. COLOR LOCATION Storefront See Sheet N -1 the Tenant's Contractor shall install. w w W t Room turns w inum : e 4 Below res mns —4 w hics w #' Indicates Tenant shall furnish materials and the Tenant's Contractor shall install. • Indicates Tenant shall furnish and install materials. NOTE 2: T.G.C. TO FURNISH AND INSTALL MOULDING ON ALL EXPOSED EDGES AND INSIDE CORNERS OF FRP PANELS. NOTE 3: 13" x 26 3/8" PIETRA FORTE CERAMIC 11LE DESIGNATED FOR USE AS BASE ARE TO BE CUT TO 6 "H X 13 "L PIECES ON SITE BY T.G.C. T.G.C. TO INSTALL WITH TIGHT BUTT JOINT. T.G.C. TO FURNISH AND INSTALL HYDROMENT MEDIUM GREY GROUT TO BE USED AS MINIMAL AS POSSIBLE. NOTE 4: T.G.C. TO INSTALL SLATWALL WITH ADHESIVE AND CHROME FLATHEAD SCREWS. 09680 09550 09300 09300 09300 09300 09300 09390 09390 09390 09390 09300 09300 09660 09678 08410 MODULAR CARPET w /CUSHION 36" x 36" WOOD BASE 3/4 "W x 6 "H CERAMIC TILE 3/8" x 12 x 12" (Matte Finish) RESERVED CERAMIC TILE 3/8" x 12 x 12 (Matte Finish) CERAMIC 11LE 3/8" x 12" x 12" (Matte Finish) CERAMIC 11LE 3/8" x 12" x 12" (Matte Finish) RESERVED CERAMIC 11LE 3/8" x 12" x 12" (Matte Finish) TRANSITION STRIP Carpet to VCT TRANSITION STRIP Carpet to Tile Tile to Mall Tile TRANSITION STRIP Concrete to VCT TRANSITION STRIP Carpet to Conc. CERAMIC 11LE 8" x 8" CERAMIC 11LE COVE BASE 6 "H x 8 "W V.C.T. 12 "x12 "x1 /8" VINYL BASE 4" High Cove METAL BASE 6 "H x 3/4 "W Milliken (Poplar Sele Granti Fiandre Granti Fiandre Granti Fiandre Granti Fiandre Granti Fiandre Burke Mercer Schluter Systems Burke Mercer Burke Mercer DAL -11LE DAL -11LE Azrock Burke Mercer Stylmark Tonal Vistas P/6017 Tweedsdale ct Grade) Tinte Unite Tinte Unite Tinte Unite Tinte Unite Tinte Unite 152 Scheine AE -100 735 700 Vitrestone Vitrestone V858 110269 16 Stony Lan e Paint Black G220CM Levanto P680CM Blue P650CM Black P610CM Grey 204 Gray 204 Gray 204 Gray Pewter Gray 204 Gray Satin Natural Satin Aluminum Sales Area See Note 4 Below iling Sales Area See Detail 13/A -4 See Note 2 Below Storefront Entrance See Note 5 Below Storefront Entrance See Note 5 Below Storefront Entrance See Note 5 Below Storefront Entrance See Note 5 Below Sales Area See Detail 1/A -4 Storefront, Sales Area See Details 4 & 5/A -4 See Note 1 Below Egress to Service Corridor Door, See Detail 2/A -4 Stockroom, Egress Corridor,Toilet Room Stockroom, Egress Corridor,Toilet Room VERIFY MALL FLOORING THICKNESS PRIOR TO ORDERING MATERIAL PAINT WOOD BASE WITH LATEX SA11N ENAMEL RESERVED RELEASABLE MIWKEN CARPET ADHESIVE TO BE FURNISHED BY TENANT AND INSTALLED BY TENANT'S CONTRACTOR. NOTE 5: CERAMIC FLOOR TILE AND BASE TO BE INSTALLED WITH TIGHT BUTT (1/8" MAX.) GROUT JOINT. T.G.C. TO FURNISH AND INSTALL gECEIYE? HYDROMENT MEDIUM GREY GROUT OR APPROVED EQUAL GROU6If9 of TUKWLA BE USED AS MINIMAL AS POSSIBLE. MAR 032008 PERMIT CENTER NOTE: T.G.C. MUST VERIFY QUANTITIES OF FLOORING MATERIALS WITH INSTALLER AND SUPPUER DURING FIRST TWO WEEKS OF PROJECT AND INFORM SUPPLIER OF ANY DISCREPANCIES BETWEEN SUPPLIER'S QUANTITY TAKE —OFF AND INSTALLERS QUANTITY TAKE —OFF. T.G.C. MUST VERIFY DELIVERY QUANTITIES WITHIN 24 HOURS AFTER DELIVERY AND IMMEDIATELY NOTIFY SUPPUER OF ANY DISCREPANCIES. V J c J Lil a Z UJ < L>J r� V W Z L L i SHEET NUMBER A -2 SHEET 6 OF 17 JOB NO:FY-06-01-D STORE NO: 1245 CHECKED: CM FINISHED CEILING HEIGHT PLAN KEY CSI SECTION MATERIAL/ DESCRIPTION MFR. STYLE/ CAT. NO. COLOR LOCATION ® 09510 CEILING 11LE 2' x 2' x 3/4" USG Frost 1414 Shadowline White Sales Area Tegular Lay—In Bevel © 09510 GRID Donn 15/16" DX White Sales Area 2' x 2' Exposed Tee O 09510 CEILING 11LE USG 562 White Stockroom 2' x 4' x 5/8" Fissured Egress Corridor Lay—in ® 09510 GRID Donn 15/16" DX White Stockroom 2' x 4' Exposed Tee Egress Corridor Qe 09250 Ceiling /Soffit F.C. Gypsum Wall Sales Area Soffits, Toilet Room Board EXTENT OF GYP. BD. CEILING OO TOILET ROOM GYP. BD. CEILING 7 -6' A.F.F. WITH PLATFORM ABOVE NOTE STOCKROOM LAY -IN CEILING TO CONTINUE ABOVE TOILET ROOM. ELECTRICAL EQUIPMENT, REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION GYP. BD SOFFIT MIN. OF 7' -0' A.F.F. AT AREA OF STRUCTURAL BRACING, T.G.C. TO ADJUST CEIING AS REQUIRED 9 STOCKROOM FINISHED CEILING HEIGHT 12' -0" A.F.F. NOTE: STOCKROOM LAY-IN CEILING TO CONTINUE ABOVE TOILET ROOM. EGRESS CORRIDOR FINISHED CEILING HEIGHT I S 10' -0' A.F.F. EGRESS ALCOVE FINISHED CEILING HEIGHT 8' -0" A.F.F. PAINT TO MATCH CORRIDOR FINISHES NOTE: MAINTAIN 1 HR. FIRE RATING AT ALCOVE SE DETAIL 2/A -3 FOR ADDITIONAL INFORMATION EXIT FIXTURE TO BE WALL MOUNTED, CENTERED ABOVE DOOR AT 7 -6' A.F.F. TO CENTERUNE OF FIXTURE TOILET ROOM SEE SHEET A -1 r L -, L STOCKROOM FINISHED CEILING HEIGHT S 10' -0' A.F.F. Section through Toilet Room H I--I 0 .5 1 2 4 FEET N01E: UNDERSIDE OF CORRUGATED METAL DECK IS 19' -1' A.F.F. & 20'- 11'A.F.F. STEEL BEAMS SPAN FRONT TO BACK AND SIDE TO SIDE. LOWEST CN.EAR HEIGHT TO STRUCTURE IS 17 -9' A.F.F. THERE I5 NO SPRAY ON FIREPROOFING OTHER THAN ON COLUMNS ATTACHED TO X- BRACING. NOTE CEILING GRID TO BE CENTERED WITHIN SPACE UNLESS OTHERWISE NOTED. NOTE: ALL SPEAKER WIRE TO BE MINIMUM 16 GA. PLENUM RATED. ALL WIRING TO BE FURNISHED AND INSTALLED _ BY TENANT'S A/V VENDOR NOTE: T.G.C. TO COORDINATE AUDIO SYSTEM REQUIREMENTS WITH TENANTS PROJECT MANAGER. ELECTRICAL CONTRACTOR TO PROVIDE 20 AMP DUPLEX RECEPTACLE AT (3) SPEAKER LOCATIONS FOR SUB - WOOFERS. VERIFY QUANTITY AND LOCATIONS PRIOR TO CONSTRUCTION. INSTALL 16 GA. CHANNELS, ATTACHED TO FULL HEIGHT STUDS, AT END OF JOISTS 6" 18 GAUGE METAL STUDS 0 16' O.C. 3/4' FIRE RETARDANT PLYWOOD DECK 1 X 3 TRIM (FIRE RETARDANT) PAINT TO MATCH ADJACENT WALL FINISH gip FINISHED PLATFORM HEIGHT 8' -1 3/8' ® FINISHED CEILING HEIGHT 7 -6' Mk TOP OF DOOR HEIGHT \IF6'-8" BOX BEAM HEADER CONSISTS OF (2) C3 5/8' 20 GA. METAL STUDS WITH METAL TD 3 5/8' 20 GA. TOP AND BOTTOM SCREW FASTENED TO METAL STUDS. 2 A/A- NOTE T.G.C. TO PROVIDE FLUSH MOUNTED METAL ACCESS PANELS WITHIN ALL GYP. BD. CEILINGS AS REQUIRED TO ACCOMODATE ACCESS TO ROLL-UP GRILLE, MECHANICAL AND ELECTRICAL SYSTEMS. SEE SHEET N -1 FOR ADDITIONAL INFORMATION. NOTE NO COMBUSTIBLES TO BE INSTALLED ABOVE CEILING. NOTE: SPACE IS PROTECTED THROUGHOUT BY AN AUTOMATIC SPRINKLER SYSTEM. NOTE REFER TO MECHANICAL DRAWINGS FOR THE LOCATION OF DIFFUSERS AND SPRINKLER HEADS. NOTE: TENANTS CONTRACTOR TO VERIFY FIXTURE PLAN AND INTERIOR SIGNAGE AND GRAPHIC PANELS WITH TENANTS PROJECT MANAGER PRIOR TO INSTAWNG SALES AREA TIGHT FIXTURES. EGRESS ALCOVE FINISHED CEIUNG HEIGHT Sio 8' -0" A.F.F. ALL FRAMING AND G.W.B. FOR DOOR RECESS BY T.G.C. RECESSED WALL SURFACES AND DOOR TO BE PAINTED BY T.G.C. TO MATCH EXISTING CORRIDOR PAINT SERVICE CORRIDOR T.G.C. TO PROVIDE 6"x6'x42" HIGH, 16 GA. METAL ANGLE CORNER GUARD BASE TO MATCH LANDLORD'S CORRIDOR Egress Alcove 1-1 0 .5 1 2 4FEET NOTE: SEE SHEET N-1 FOR SEISMIC DETAILS RELATING TO THE CEIUNG INSTALLATION. - EXTEND TO DECK. SEE SHEET N -1 FOR ADDITIONAL INFORMATION. EGRESS CORRIDOR ALFINISHED CEILING HEIGHT 10' -0' A.F.F. 5/8" GYPSUM WALL BOARD TYPE -X 3 5/8' METAL STUDS 16" O.C. ILLUMINATED EXIT SIGN T G.C. TO PROVIDE PENDANT SPRINKLER HEAD AND CONNECTIONS TO FEED FROM TENANTS OWN SPRINKLER SYSTEM AT EGRESS ALCOVE REFER TO DOOR SCHEDULE FOR RATED DOOR AND HARDWARE REQUIREMENTS TENANT SPACE NOTE: 1. ALL RECESSED WALL SURFACES MUST BE PAINTED BY T.G.C.. 2. T.G.C. TO SEAL ALL EXPOSED CONCRETE FLOORS NOTE EGRESS ALCOVE TO BE ONE HOUR FIRE RATED CONSTRUCTION PER U.L DESIGN i' J -465 SALES AREA A FINISHED CEILING HEIGHT 12' -0" A.F.F. CHANNEL• MOLDING AT ENDS TYP. BY SUSP SYSTEM MANUFACTURER FACE OF WALL NOTE: T.G.C. MAY FRAME SUSPENDED GYP. BD. CI:RINGS AND SOFFITS CONVENTIONALLY OR WITH 7/8' FURRING CHANNELS AT 48' O.C. MOUNTED TO 1 1/2" COLD ROLLED CHANNELS AT 48" O.C. SUSPENDED FROM STRUCTURE ABOVE MATH MIN. 12 GA. GALVANIZED STEEL WIRE AT 48' O.C. GYPSUM BOARD CEIUNG Typical Detail H 4 S INCHES 2 Key to Reflected Ceiling CEILING AND SOFFIT FINISHES NOTE: ALL CEIUNG 11LE TO BE CLASS A RATED. CEILING MOUNTED SPEAKERS AND WIRING TO CASHWRAP TO BE FURNISHED AND INSTALLED BY TENANTS A/V CONTRACTOR, TYP. OF 10 1 1/2" HIGH X 15/16" FLANGE MAIN TEE SUSPENDED W/ MIN. 12 GAUGE GALVANIZED STEEL IMRE 48' O.C. EACH WAY 7/8' CROSS CHANNEL WITH KNURLED FACE INSTALL PERPENDICULAR TO MAIN TEE 5/8" TYPE "x" GYPSUM BOARD CEILING NOTE: INSTALL MAIN TEES AT 4' -0" O.C. NOTE: INSTALL CROSS CHANNELS AT 24" 0.C. 23' -6' Light Fixture Schedule 16500 LIGHTING ^ . ^V^ ^'. 16500 - LIGHTING CEIUNG MOUNTED LIGHT FIXTURES STYLE/ SYMBOL DESCRIPTION MFR. CAT. NO. 2'x2' Fluorescent Light Fixture w/ 9 CeII White Parabolic Lens Surface Mounted Single Circuit Track System (Silver) Incandescent Gimbal Ring Open Back MonopointTrack Head (Silver) 4" Recessed Incandescent Downlight 8" Recessed Incandescent Downlight Exit Light Fixture with 90 Minute Battery Backup Recessed Emergency Ught with 90 Minute Battery Backup Combination Fan/ Light 100 CFM 9 Recessed Compact Fluor. Downlight 4' Fluorescent Strip Fixture Surface Mounted Emergency Light with 90 Minute Battery Backup Designates Night —light UGHTOLIER JUNO JUNO JUNO JUNO ATLITE DUAL —UTE NUTONE JUNO SIMKAR ATLITE PLA2G9WP 3FT277X3 T2NA, T4NA, T6NA, T8NA V689NA TC44/ 447CWH MC8P3870/ 8838CWH PNLRU EZ -2R 8663P CH9 226/ 32/42T- 950CWH CH -232 PCI -10 3 PLL4O /35K 277 Volts (3) U -40W 120 Volts 120 Volts 75W PAR 30 NFL 120 Volts 50W MR16 FL EXN 120 Volts 70W PAR38 MH FL 277 Volts (2) 15T6 12W 277 Volts 8W 120 Volts 1 -100W 120 Volts (2) 42W 35K 277 Volts 2 —F32T8 TL735 120/277 V 8W N/A 1 N/A �C1 0 OD1 B 1 =1 F OPL SF 12' -0' EXTENT OF GYP. BD. CEILNG 2' -0" dog VOLTS/ LAMPS COMMENTS Sales Area See Note 1 Below Sales Area (Storefront Soffit) Sales Area Sales Area, Stockroom Egress Corridor NOTE 1: ALL FLUORESCENT LAMPS SHALL BE CHROMA 30 (UNLESS OTHERWISE NOTED). ALL LIGHT FIXTURES SHALL BE FURNISHED BY TENANT AND INSTALLED BY T.G.C. NOTE 2: T.G.C. TO FIELD VERIFY EXACT LOCATION & POSITIONING OF TRACK HEADS WITH TENANT'S PROJECT MANAGER PRIOR TO INSTALLATION. SOFFIT S FINISHED CEILING HEIGHT 11' -10' AF.F. SOFFIT AUL FINISHED CEILING HEIGHT 13' -10 1/4" A.F.F. Sales Area Toilet Room Storefront Soffit Stockroom Egress Corridor Stockroom, Toilet Room Egress Corridor NOTE: LIGHT FIXTURE 'D' TO BE CENTERED BETWEEN GLAZING CHANNEL AND ALUMINUM PANEL VOLTARC SPARKLJNG BLUE NEON ACCENT STRIP W/NATURAL ALUMINUM PANEL ON FACE OF SOFFIT, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. SE DETAIL 2/A -1.1 FOR ADDITIONAL INFORMATION. LEASE LINE CENTERLINE OF MANUAL ROLL-UP GRILLE, PAINT RETURNS ENTRY SOFFIT FINISHED C ILING HEIGHT 10' -0' A.F.F. INTERNALLY ILLUMINATED LOGO SIGN CABINET, SEE STOREFRONT ELEVATION AND SECTION FOR ADDITIONAL INFORMATION CENTER EXIT SIGN ON FACE OF SOFFIT SO AS NOT TO BE VISIBLE FROM MALL COMMON AREA SOFFIT M FINISHED CEILING HEIGHT 13' -10 1/4' A.F.F. VOLTARC SPARKLING BLUE NEON ACCENT STRIP W/NATURAL ALUMINUM PANEL ON FACE OF SOFFIT, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. SEE DETAIL 2/A -1.1 FOR ADDITIONAL INFORMATION. SOFFIT AI h i FINISHED CEILING HEIGHT 11' -10" A.F.F. Rte ONED CODE COMPLIANCE ', P. A _ 3r APPR0V U OM MAR `2 fi ' O Tu" l�: BU1LD1 RECEIVED CITY OF TUKVWLA MAP 0 3 2008 PERMIT CENTER 0 Ch F, F, D g B 3 - as E IIl7 7-• N CD o d" r � hA M M To co dg cD cD U 0 C0 C0 CN1 CO 00 C0 Q 0) Q Q.) v 0 r � C J r � Li) cco CO In In 41 11] M Eta, Z n T Z 0 op Z •• 1: IX 3d a ° ` LI- J SHEET NUMBER A -3 SHEET 7 OF 17 SALES AREA A /A - CARPET TILE / VCT Transition Detail 0 1 2 4 8 INCHES 7 A /F - BACKROOM SIDE NOTE TOP OF FLOORING AND TRANSITION STRIP TO BE SAME HEIGHT. NOTE VCT FLOORING TO BE TIGHT TO TRANSITION STRIP. STOCKROOM WORKTABLE Typical Detail 0 .5 1 2 4FEET LAY-IN CEILING AT 12' -0' A.F.F. LINE OF STOCKROOM WALL 3/4" X 16' PLYWOOD SHELVES WITH EDGE BAND, FURNISHED AND INSTALLED BY TENANTS GENERAL CONTRACTOR 48" HEAVY DUTY SURFACE MOUNTED WALL STANDARDS WITH 1" SLOTS 2' D.C. AT 24' O.C., SECURE TO WALL WITH TOGGLE OR EXPANSION BOLTS, FURNISHED AND INSTALLED BY T.G.C. 14" 90' METAL SHELF BRACKET FURNISHED AND INSTALLED BY T.G.C. 3" O.C. PREFINISHED SLATWALL WORK TABLE FURNISHED BY TENANT AND INSTALLED BY T.G.C. FINISHED FLOOR MALL EGRESS CORRIDOR NOTE: FLOORING TO BE TIGHT TO TRANSITION STRIP. 4 TENANT SIDE CONCRETE / VCT Transition Detail 8 INCHES VINYL TRANSITION STRIP% VCT FLOORING <>. r 7 -0' - 11HY 4 .„■ 8 7 STOCKROOM WORKTABLE Typical Detail 0 5 1 2 4 1 FEET PLYWOOD SHELVES, SEE DETAIL 7/A -4 WALL STANDARDS, SEE DETAIL 7/A-4 FINISHED FLOOR NOTE: REFER TO PLAN FOR CORRECT ORIENTATION. OUTSIDE CORNER DETAIL TypicaJ Detail 3' D.C. PREFINISHED SLATWALL ELECTRICAL RECEPTACLE TIP. 48" A.F.F. SEE ELEC. DINGS. WORK TABLE FURNISHED BY TENANT AND INSTALLED BY T.G.C. H I 1 0 1 2 4 8 INCHES CERAMIC TILE FLOORING v,.% pe r•0- 0:444r24 r' -r FLASH PATCH FLOOR AS REQUIRED TO ACHIEVE LEVEL TRANSITION GYPSUM WALL BD. 1)1'. SLATWALL GLUED AND SCREWED DIRECTLY TO FACE OF G.W.B. 3/4" x 3/4" x 3/32" ANGLE WITH SATIN NATURAL FINISH. APPLY TO FACE OF SLATWALL WITH CLEAR SIUCONE ADHESIVE GYPSUM WALL BD. TYP. SLATWALL GLUED AND SCREWED DIRECTLY TO FACE OF G.W.B. CARPET TILE CERAMIC 11LE / CARPET TILE Transition Detail H HH 1 1 2 4 8 INCHES m NOTES: TOP OF FLOORING AND TRANSITION STRIP TO BE SAME HEIGHT. FLOORING TO BE TIGHT AGAINST TRANSITION STRIP. SCHLUTER TRANSITION STRIP O ti NOTE REFER TO PLAN FOR CORRECT ORIENTATION. INSIDE CORNER DETAIL Typical Detail 1 2 4 8 INCHES NOTE TOP OF TENANTS/MALL FLOORING AND TRANSITION STRIP TO BE SAME HEIGHT. FLOORING TO BE TIGHT AGAINST TRANSITION STRIP. FLASH PATCH FLOOR AS REQUIRED TO ACHIEVE LEVEL. TRANSITION CERAMIC TILE FLOORING f 1461 GYPSUM WALL BD., TYP. EB 3/4' x 3/4' x 3/32' ANGLE WITH SATIN NATURAL FINISH. APPLY TO FACE OF SLATWALL WITH CLEAR SIUCONE ADHESIVE SLATWALL SLATWALL GLUED AND SCREWED DIRECTLY TO FACE OF GWB TYP. 5/8' GYPSUM WALL BOARD AND METAL STUD PARTITION GYPSUM BOARD SEE INTERIOR ELEVATIONS FOR FINISHES 7 -3" A.F.F. TOP OF SLATWALL 3/4' x 3/4' x 3/32' ANGLE WITH SATIN NATURAL FINISH. SCREW TO SLATWALL FROM TOP. NO EXPOSED FASTENERS ON VERTICAL FACE SLATWALL GLUED AND SCREWED DIRECTLY TO FACE OF GWB TYP. METAL CAP AT TOP OF SLATWALL Typical Detail 0 1 2 4 8 INCHES CENTERLINE OF GRELE v i SCHLUTER TRANSITION STRIP% MALL TILE 11LE / MALL TILE FLOORING Transition Detail 1-1 1 NOTE T.G.C. TO EXTEND MALL 11LE TO CLOSURE UNE AS REQUIRED INSTALLATION FLANGE TO BE UNDER TENANT FLOORING 1 2 4 8 INCHES 1' x 1" x 1/8" ANGLE V1TH SATIN NATURAL FINISH. APPLY TO FACE OF SLATWALL WITH CLEAR SIUCONE ADHESIVE TYP. SLATWALL 3/4' x 3/4' x 3/32' ANGLE WITH SA11N NATURAL FINISH. APPLY TO FACE OF SLATWALL WITH CLEAR SIUCONE ADHESIVE TYP. OA A /A -1 1 1 .11111 I :I 1 NOTE W000 BASE TO BE PAINTED BLACK W111 LATEX ENAMEL BASED PAINT. 6 HIGH WOOD BASE SLATWALL GLUED AND SCREWED DIRECTLY TO FACE OF GWB TYP. 6' HIGH WOOD BASE CARPET 11LE O Tyc&DetaiI 0 1 2 4 8 INCHES Typical Detail 1 2 1 OPEN END 3" DIA. PVC TUBE (WHITE) 3/16' HOLE FOR MOUNTING SCREW TO OPPOSITE SIDE FROM 1/2' HOLES (TIP. OF 2) TEXT ON SIDE OF TUBE TO BE RIT W TEN WITH BLACK MARKER IN FELD BY TENANT'S GENERAL CONTRACTOR 1/2" HOLE TO ALLOW FOR A SCREW DRIVER ACCESS (TYP. OF 2) SCREW HEADS TO BE FLUSH MOUNTED W/ WASHER INTO PLYWOOD SCREW (TYP. Cr 2) BOTTOM END CAP (GLUED) BOTTOM END HEIGHT 1 ii? 4' -0' A.F .F. NOTE: PLAN TUBE TO BE FASTENED TO WALL WITHIN STOCKROOM AND TO BE FURNISHED AND INSTALLED BY TENANTS GENERAL CONTRACTOR (1 PER STORE) SEE FIXTURE PLAN FOR LOCATION. Plan Tube Detail 2 4 6 12 INCHES � w Arlip $ %III / /7rJAA44 AV ��// Z NOTE REFER TO PLAN FOR CORRECT ORIENTATION. COLUMN BUMP OUT DETAIL 8 INCHES CEILING HEIGHT -- VARIES, SEE REFLECTED CEILING PLAN GYPSUM WALL BOARD, SEE SHEET A -1 FOR PAINT FINISH DESIGNATION 1' X 1' X 1/8' THICK ANGLE WITH SA11N NATURAL FINISH. APPLY WITH CLEAR SILICONE ADHESIVE 3/4' PLYWOOD WITH LAMINATE WAINSCOAT, FURNISHED BY TENANT, INSTALLED BY T.G.C. NOTE T.G.C. TO CONSTRUCT COLUMN ENCLOSURE TO MINIMAL DIMENSIONS 6' HIGH BASE % FINISHED FLOOR v/ SLATWALL M 5/8* GYPSUM BOARD 1 x 1" x 1/8 ANGLE WITH SATIN NATURAL FINISH. APPLY TO FACE OF SLATWALL WITH CLEAR SIUCONE ADHESIVE TYP. SIATWALL EXISTING DEMISING WALL EXISTING COLUMN Dio0//5' 16 VARIES INTERIOR COLUMN Typical Detail H F-- --- -I 1 0 4 8 16 32 INCHES 0 i SLATWALL GLUED AND SCREWED DIRECTLY TO FACE OF G.W.B. GYPSUM WALL BD., TYP. 3/4" x 3/4" x 3/32' ANGLE WITH SATIN NATURAL FINISH. APPLY TO FACE OF SLATWALL WITH CLEAR SILICONE ADHESIVE NOTE REFER TO PLAN FOR CORRECT ORIENTATION. EXPOSED END OF SLATWALL Typical Detail 1-1 0 1 2 4 8 INCHES COMPUANCE CODE APPROVED BUILDIN DIVISION RECEIVED CITY OF TUK\MLA MA 0 3 2008 PERMIT CENTER J iffilt 1Y1Y1 SHEET NUMBER A 4 SHEET 7 OF 17 ■,r ^ 3' - 1 — o " ACCESSIBLE COUNTER REGISTER WELL r NOG - iZ SURFACE MTD. PAPER CUP DISPENSER, BOBRICK MODEL I(8 -235, FURNISHED AND INSTALLED BY T.G.C. BOTTOM OF DISPENSER TO BE 39" A.F.F. DRINKING WATER FOUNTAIN, SEE PLUMBING DRAWING FOR ADDITIONAL INFORMATION ELECTRICAL EQUIPMENT, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION FOLDING TABLE, FURNISHED AND INSTALLED BY TENANT ELECTRICAL EQUIPMENT, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION FILE CABINET, FURNISHED AND INSTALLED BY TENANT 7' -0' WORK TABLE W /SLATWALL AND SHELVES ABOVE, SEE DETAILS 7 & 8/A 4 POS CABINET, FURNISHED AND INSTALLED BY TENANT FIRE EXTINGUISHER, T.G.C. TO VERIFY REQUIREMENTS WITH LOCAL AUTHORITIES LVS STATION, FURNISHED AND INSTALLED BY TENANT PREFABRICATED SHELF AND BRACKET, FURNISHED AND INSTALLED BY TENANT. GENERAL CONTRACTOR TO INSTALL BLOCKING IN WALL COORDINATE WITH TENANTS PROJECT MANAGER. EMPLOYEE LOCKERS, FURNISHED AND INSTALLED BY TENANT 36" WIDE x 24" DEEP x 60" HIGH STOCKROOM SHELVING, FURNISHED BY TENANT AND INSTALLED BY T.G.C., TYP. T.G.C. TO FURNISH AND INSTALL COAT HOOK STRIP BOBRICK # B- 232X36 CR APPROVED EQUAL T.G.C. TO FURNISH AND INSTALL PLAN TUBE, SEE DETAIL 6 /A -4 L r -- I I L__ MINIM Loc <ers F -1 I-1 Coots a 1 1 Pl EGRESS CORRIDOR 0 1 2 4 STOCKROOM STOCKROOM 2'x3' Shelving NOTE: CD AND /OR DVD FLOOR FIXTURES TO BE SCREWED TOGETHER, BACK TO BACK FASTENERS TO BE INSTALLED IN AREAS NOT VISIBLE TO THE PUBUC. COORDINATE REQUIREMENTS 1MTH TENANTS PROJECT MANAGER PRIOR TO INSTALLATION. NOTE: T.G.C. TO INSTALL TENANT SUPPLIED SINTRA CATEGORY DIVIDERS ALONG SLATWALL DIVIDERS FURNISHED WITH S.ATWALL BRACKET'S. APPROXIMATELY (7) DIVIDERS REQUIRED FIELD VERIFY EXACT LOCATION WITH TENANT'S PROJECT MANAGER. / n 1 Fixture X811 TOILET ROOM • I 1. 5 Folding Table POS 2'x3' Shelving 8 FEET File LVS 2'x3' Shelving 0 (n W 7 Q a 0 In W Z 1- 0 1- d 0 CV S rn 6' -0" T- -A_FIG 5 -0" NOTE: T.G.C. TO INSTALL CD MERCHANDISERS PER TENANT ASSEMBLY DIAGRAMS. COORDINATE WITH TENANTS PROJECT MANAGER. 3' -6' 5' -6 3/4" NOTE: "IF CASHWRAP I5 SHIMMED" T.G.C. TO INSTALL BLACK VINYL COVE BASE AROUND ENTIRE PERIMETER OF FIXTURE NOTE: T.G.C. TO PROVIDE CONDUIT WITH PULL STRING TO EACH FIXTURE RUN CONTAINING LVS UNITS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 6' -0" T— RTC 0 C 3' -5 1/2" TW32— 5 W T —RTG 15 -0" 15-0" 6' -0" C.7 w 14-1 0 W J fez 0 0 10" A /F - BL_ MED 5' -0" CD — TW32— 5 4' -0" DVD— T5BR DVD —T5BR DVD —WL 1-B R 44' -0" V -0" 2' -2" 5' -0" AC C SALES AREA FLOOR FIXTURE, TYP. LVS UNIT, FURNISHED AND INSTALLED BY TENANT, TYP. OF 8 COLUMN ENCLOSURE, SEE DETAIL 15/A -4, TYP. OF 4 PLAN FRONT ELEVATION 4 -0" . ELEC Accessible Cashwrap Detail 0 .5 1 2 1 FEET 3' -11 1/2" . ELEC 30' -0" CD— TW32— 5 CD--- TW32 ----5 3' -6" 35' -0" vJ W 4 10 CD— TW32 -5 CD— TW32 -5 LVS3 SALES AREA WWE SH OP 8'-0" 20' -0" 24' -0" P. ELEC DVD - --T5BR DVD -- --T5BR 3' -10" DVD COLL 8' -D" 0 FEAT 2x2 1 W 6' -6" 3' -9" IY z 0 0 Iz z 0 0 1' I X17 LVS3 c&2 cr 0 0 z z 0 U 4' -6" V -6" FIRE EXTINGUISHER, T.G.C. TO VERIFY REQUIREMENTS WITH LOCAL AUTHORITIES AUGN END OF SLATWAU. WITH EDGE OF CASHWRAP 2 DVD 4W1 CO • 7) T\\/fD •/ 26' - D" 19' -0" CASHWRAP CASHWRAP 4' -O" 4 -0" TYP. 1' -0 EXTENT OF CARPET TILE FEAT 2x2 1 f E XTE 4 T aF CERAMIC TWLE "o J I � 3' -6" I� L NOTE: CASHWRAP TO HAVE A MINIMUM 36" WIDE AREA A MAXIMUM OF 34" A.F.F. TO COMPLY WITH HANDICAP ACCESSIBILITY REQUIREMENTS. VENTED CABINET HANDICAP ACCESSIBLE CASHWRAP COUNTER, SEE DETAIL 1/F -1 LEASE LINE PROFILE OF SOFFIT ABOVE EXTENT OF TENANT CERAMIC "TILE / CENTERLINE OF ROLL UP GRILLE, SEE DETAIL B/A -1.2 PEDESTAL TYPE S]NSGRMATIC SECURITY SYSTEM, TYP. OF 2 PROFILE OF SOFFIT ABOVE !l5 • CODE s A PP ROVED 1 City Df Tai , �w a Bv'_ L___v -1, ai+ RECEIVED CITY OF TUKWW ILA MAR 0 32008 PERMIT CENTER amcal IY1111011 J SHEET NUMBER F -1 SHEET 9 OF 17 Tel: 781-331-4000 7' Work Table PROJECT COORDINKTION: Fax: 781-335-2115 JOB NO:FY-06-01-1D STORE NO: 124E3 CHECKED: CM FEAT TABLE EC S* 1 -5/8' meld dud (20 9*4e) up to 12'-0" Bad -to-bxk 1 -5, mew shd ( gage) up to 15' -0' Segk 2 metal scud (20 gciige) up to 13' -6' Bk -t°4 2 1 metal stud (20 gage) up to 15' --0' EMT CONDUIT 1/Y ELT conduit up to 5' -10" 3/4 ELT conduit up to 7 -8' 1' EMT conduit up to 9' -9' WE Fla Gwil= kr wuL A65enfRY re' Nor REI1e1@ Ta MIN OEM TA= MVO. MN SO >d SF KU tlN 6 - aim I EERSICs a= lEac As7f£ Td =Woo= k1UJFr ran MPH P. , ,, , , , LATERAL BRACING B /A -1 Typical Detail 1-1 s i z a FEET • .a . 4 a 1 HOUR TENANT TO CORRIDOR PARTITION Typical Detail NO SCALE NO SCALE i •e a dr:4 FY+I:i11 SEE STINJC1UPA_ DRA 3-5/8' 20 GA. DIAGONAL METAL BRACING AT 8' -0' O.C. (ALTERNATE SIDES AND INSTALL BRACING AT 4' -O' O.C. INTERVALS) ATTACH TO STRUCTURE ABOVE CEILING (SEE SIEET A - 3 FOR fUGI1) 5/8" TYPE ' X ' GYPSUM BOARD TYP. 3-5/8' METAL STUDS AT 16' O.C. TIP. S`iP9,.Ir DOM EELDZI men PER 9k -EDULE rd1Pai Blum TSPE ' Omni sal LLLICL THE MOM MT N% Ie0ai3EY0 we rue m na..IL• StOrtMpa roe 11c scan lttaw% corral LL's ooamonensr rot eon= ALT 11:1MBEITTFAI tuawJ_E ;FM e smur seams lir 1IsY,4FI Imm TOOT= SILIZ Arm nowt Ana 41111O B ( R11iKLeaWEe sea =MS S I IL eL am ▪ Cr EMS Goo 1Z R Q, Y me FEUD kf THE We. JQIre SHERD mou r .ue SrMOSTE1 alt ape= rue EF TIE =WI. 1ILE VNISCOT. 1I44ff MERE CCCURta • s1EEL STLMS 1r B RHO PER Sa'ELULE • CONTNiars fJ .n0-Eo STEEL 1P.Mi( FRISH U ERE ODELFs £LLEU CJiNcRETE 9Ln9, 91E STRUCIBRAL DRAM PARITAI .E FItESTSP Ef:A MT Omni SCIM) AJ EET A9 Ft134.1RED 'MERE WYJ_ MUTTS 8 IERART %PACE, +91P/11J BOARD LAWNS SOIL BE BsmkIErl AND IH9TJUIFD BY TENANT C BY TENANT (sateeE acmes) STEEL STUDS ® 1i1" Q.C. 5/B GPPSUM BOARD TYPE X (BuW SIDES) Na. U4135 1 THE FOLLONNB F,- iEFUNG RECIUB:EkIEEnS' ARE TAKEN FROM uCS WEaIiCATWN FaR THE INU1CAlED AS°arJBLY. REFER TD UL's DOCUIILNfADoN FOR 0311PIEEE ASSBIBLY REOHIREMIDITS AND ALLONABLE C'•11 J,,; crams ROM 5/8' 1HI13f, 4 FT ME, ATTACI-ED TO STEEL SiIJE AND FLWR AND CEILING MACK YOTH 1 Ill LCNJG, TYPE S STEEL SCRIM SPACED IN. O1 ewes EDGM Cf BOARD AND 12 IN. OIC Iq 11E FIELD CIF THE 9OM. JaHTS CBRENTED YERTI JLr AHD STAGGERED on 0PPa51 sea ce THE ASSEMBLY. A6. FEaIJSED CONTINLIGLE L RLNCFEO SiIR - IRAIIL AINi>SffiE F DESTrP SEALANT (BOTH DDES) t All ell s ltd BOARD LAYERS SHALL BE SUPFilm AHD INSTALLED BY TENANT 1 HOUR TENANT TO TENANT PARTITION Typical Detail TOP OF STUD UL DESIGN U465 NONBEARING WALL RATING - 1 HR. PLAN VIEW 1. Floor and Ceiling Runners -(not shown) - channel shaped runners, 3 M. wide (min), 1 - 1/4 In. legs. farmed from min No. 25 MSG (min No. 20 MSG when Item 4C is used) gals steel, attached to floor and caning with fasteners spaced 24 in. OC max. 2. Steil Studs - Channel shaped. 3-5/8 in. wide (mks), 1 -1/4 in. lege, 3/8 ie. folded bock returns. formed from min No. 25 MSG (min No. 20 MSG when Item 4C le used) golv steed spaced 24 in. OC max- 3. Batts and Blankets•- (Optional)- Mineral wool or glass fiber batts portily or completely firtbng stud cavity. See Batts and 131cnketa (BZJZ) category for names of Classified companies. 4. We board. Gypsum' -5/8 h. thick, 4 ft wide, attached to steel studs and floor and ceiling track with 1 in. tong. Type S steel acrewe spaced 8 in. OC. clang edges of board and 12 h. OC in the field of the board Joints oriented vertically and staggered on opposite sides of the aseemblyc when attached to item 8 (furring channels), wallboard la screw attached to furring channels with 1 In. long, Type S steel screws spaced 12 in. OC. American Gypsum Co. -Type AG-C. Canadim C plum Company -Types AR, C. IP -X2. SCX. Six, wRC or VefiX Continental Gypsum Company -Types CG-C., cG5-5, CG6-6, c09-9, CGTC-C. G-P Gypsum Cap. -Types 5, 9, C. GPFSB. Jeres Hardie Gypeurn Imo. -Type BG-C. Lafarge Gypsum. A dlv. of Lafarge Corp. -Types LGFC6, LGFC -C. National Gypsum Co., Charlotte, NC - Types : SK FSa -G. National Gypsum Co.. Riyadh, Saudi Arabia -Type FR cr wR. Pct.= Gypsum Co. -Type PG-C. Republic Gypaum Co. -Type RG-C. Standard Gypstlin Corp.-Type SG-C. Temple - inland Forest Products Corp. -Type TG-C. United States Gypsum Co. --Tpe AR, C, IP -X2, SCX. SI1X. WRC or WRX Yeso Pacemericarko SA de CV -type AR. C, tP - X2, SCx. SHX, sec cr MRX. Westroc Inc. -Type westroc FTreboard. 44. Wdtbocrd, Gypsums-(As an alternate to Item 4 )-Nan 3/4 in. thick. 4 ft wide, installed as described In item 4 with are length increased to 1 -1/4 in. Canadian Gypsum Company -Type AR. United States Gypsum Co. -Type AR. Yeso Panamerdeano SA de CV -Type AR. 48. Wallbocud, Gypsums' -(As an alternate to Items 4 and 4A) -5/8 in. thick installed as described in Item 4. Joint covering (Item 5) not C anadian Gypsum Company -Type VeSX. United States Gysum Co. -Type WSX. Yeeo Pananertcano SA de CV -Type WSX. 4C. Wallboard, Gypsum" -(As an attemate to Item 4, 4A and 48) -5/8 in. thick gypsum panels, installed as described in Item 4 with Type S-12 steel screws. The length and spacing of the screws as specified under item 4. Canadkn Gypsum Company -Type FRX. United States Gypsum Co. -Type FRX. 5. Joint Tape and Compound - Vinyl. dry or premixed joint compound, applied in two coats to joints and screw heads: per tape. 2 in. wide. embedded h first layer of compound over all joints. As an alternate, namind 3/32 in_ thlde gypsum veneer baseboard. Joints reinforced. 8. Furling Charmer- (Optional-not Shown)-Resiitent 25 MSG gcdv steel furring channels spaced vertically max 24 In. OC, flange portion attached to each intersecting stud with 1/2 is long type S-12 panhead steel screw. Not for use with Type FRX gypsum panda. *Bearing the UL Classification Marking Suspension Systems for Acoustical Lay -in Ceilings This document provides the IBC- referenced standards for the installation of suspension systems for acoustical lay-in ceilings. Incorporation of this document will provide a more uniform standard for installation and inspection. This document is designed to accomplish the intent of the International Building Code (IBC) with regard to the requirements for seismic design category D, E and F for suspended ceilings and related items. Unless supported by engineering, the suspension system shall be installed per the requirements for Seismic Design Category (SDC) D, E and F per the IBC. Manufacturers' recommendations should be followed. Countersloping ismula 4S MGE FIGURE 1 Lateral Force Bracing Maximum Recommended Lengths for Vertical Struts METAL STUDS FIGURE 3 Attached Wall Molding Requirements FIGURE 4A Unattached Wall Molding Requirements MAxwM 8 () UMW AT TTACHED FIGURE 48 FIGURE 5A ( FIGURE 58 Vertical Hanger Wire Attachment Seismic Separation Joint vERTICAL HANGER FIGURE 6A Splayed Seismic Bracing Wire Attachment FIGURE 68 FIGURE 7 NTS tamer 2' ( en) 3 TURNS H SPREADER tJilindUM 45' ANGLE 243r -111 ANQtaR STRUCTURAL car1RETE Can ap 3 MIS OR1L -11 ePARSON ANCHat 5?RUCTHRg. G:;GritE sea STRAP 1' VIDE x X 12 GAGE liNielUil SFLATTD STSec BRACING WRE General Recommendations - Referenced sources per hierarchy: 2006 IBC (International Bufidng Code), American Society of Testing Materials (ASTM C 635, AS111 C 636), American Society of Civil Engineers (ASCE 7 -05) and Celdings and Interior Systems Construction Association (MCA). - Partitions that are tied to the ceding and dl partitions greater than 6 feet in height shill be Iaterdly braced to the structure. Bracing shill be independent of the ceding splay bracing system. (saran IBC a ctioa 1821.1.2) -For further information on bracing of non -load bearing partitions refer to NWCB technical document #201. - All main beams are to be Heavy Duty (HD). ( sauce AscE 7-05 Rem 9.5.2.e.2.2e) - All cross tees shdl be capable of carrying the design load without exceeding deflection equal to 1/360 of its span. (Si cu. ascA zone' 3-4) -These recommendations are intended for suspended ceilings inducting grid, panel ar tile, fight fixtures and air terminals weighing no more the 4 lbs. per square foot. (Saxes ASCE 7-05 item 9.6.26.1) - All wire ties are to be three tight turns around itself within three inches. Twelve gage Hanger wire spaced 4 foot on center (figure 1). (Sr ano ASiV c 636 lam 2.3,4) - Changes in ceding planes win require positive bracing. (stoma Asa 7-05 Seance 9.8.2.6.2.2 Item L) Lateral Force Bracing (figures 2 and 3) - Ceilings constructed of lath and plaster or gypsum board, screw or nail attached to suspended members that support a ceiling on one level extending from wall to will shall be exempt from the lateral farce bracing requirements. (sense aSCA zone 3-4) - Lateral force bracing is the use of verticd struts (compression posts) and splay wres (see figure 2). - Lateral force bracing is required for ceilings over 144 square feet and not required for ceilings less than 144 square feet provided they are surrounded by four wails and braced to structure. - Lateral Force Bracing shill be 12 feet on center (maximum) and begin no farther than 6 feet from walls (sour= aSCA Sc ssni zone' 3- - Seismic splay wires are to be four 12 gage wires attached to the main beam. wires are arrayed 90' from each other and at an angle not exceeding 45' from the plane of the ceiling. (sae= QSCA seielnle ranee 3-4) - Seismic splay *es shall be attached to the grid and to the structure in such a manner that they can support a design Toad of not Tess than 200 pounds or the actual design toad, with a safety factor of 2, whichever is greater (figure 6b). (scree* aSCA zone* 3-4) - 'Powder driven shot -i - anchors when used far seismic application as pat of the prescriptive path in Seismic Design Categories D. E and F shad have an ICC-ES approval for seismic applications and shall require 'special inspection irrespective of the type of occupancy category the structure is in. Anchors for kicker wires (splayed wires installed for purposes other than seismic restraint) are exempt from this requirement. -Splay wires are to be within 2 inches of the connection of the verticd strut to suspended ceiling. (Scums CISCA Wink zones 3-4) - Rigid bracing may be used ki lieu of splay wires. (sere: AscE eon 9.62.6.22) - Ceilings with plenums less than 12 inches to structure are not required to have lateral farce bracing. - Vertical struts must be positively attached to the suspension systems aid the structure above. (scums CSCJt 3-s) -The vertical strut may be EMT conduit, metal studs or o proprietary compress on post (see figure 3). Wall Moldings (figures 4a and 4b) - Wall mdd'mgs (perimeter dosure angles) are required to have a horizontd flange 2 inches wide. One end of the ceding grid shad be attached to the wail molding, the other end shall have a ? inch clearance from the wall and free to Slide (Saucer ASCE 7 mike 9.13.2.6.2.2 item b) - Where substantiating documentation has been provided to the Iocd jurisdiction, perimeter dips may be used to satisfy the requirements for the 2 -inch dosure angle. The grid shad be attached at two adjacent wills (pop rivets or approved method). - Soffits extending to a point at least level with the bottom plane of the grid and independently supported and laterally braced to the structure above are deemed to be equivalent to walls. - There shad be a minimum 3/4' inch clearance from the end of the grid system at un- attached walla (Source ASCE 7-05 section 942.612 2 item b) Spreader Bars (figure 4b) - Spreader (spacer) bars shall be used to prevent the ends of the main beams and cross tees at perimeter wills from spreading open during a seismic event. Perimeter *es shag not be in lieu of spreader bars. (wick c2JGt Seismic tunas 3-4) - Spreader bars are not required at perimeters where runners are attached directly to closure angles. - Wire tying is an acceptable alternative to spreader bars. Spreader bars are not requred if a 90 degree ittersectkng cross or man is within 8 inches of the perimeter wad. - Where substantiating documentation has been provided to the local jurisdiction, perimeter dips may be used to satisfy the requirements for spreader bars. Hanger (Suspension) Wires (figures 5a and 5b) - Hanger and perimeter *es must be plumb within 1 in 6 unless (figure 5a) counter sloping *es are provided (figure 5b). (Souse: And C 836 sect* 21.4) - Hanger wires shill be 12 gage and spaced 4 feet an center or 10 gage spaced 5 feet an center. (Swett ASTM C 638) - My connection device at the supporting construction shag be capable of carrying not Tess than 100 pounds. (Serer CISCA cues 3-4) - Powder driven shot -h- anchors are an approved method of attachment for hanger wires. Termitd ends of each main beam and cross tee must be supported within 8 hales of each wdl with a perimeter wire (see figure 4 & 5 b). (sane aSCA sane' 3-4) -wires shdl not attach to or bend around interfering materiel 6.r equipment A trapeze 6.r equivalent device shdl be used where obstructions preclude direct suspension. Trapeze sus:se-40ns shill be a mk*Nnum of back -to -bads 1% inch cod - -rolled channds for spans exceeding 48 inches. (sours MCA sewn 3-4) Electrical fixtures - Light fixtures weighing less than 10 pounds shill have one 12 gage hanger ere connected from the fixture to the structure above. This wire may be slack. (Sour= aSCA &R mie teals 3-4) -Light futures weighing more than 10 pounds and less than 56 Ibs, shall have two 12 gage wires attached at opposing corners of the light fixture to the structure above. These wires may be slack. (some aSCA Saline xerwe 3 - Light Fixtures weighing more than 56 lbs. shall be supported by directly from the structure above. These wires must be tout. (Sc eree asrA SCaMIC Zane' 3 - Pendant mounted fixtures shill be directly supported from the structure above using a 9 gage wire 6.r an approved alternate support without using the ceding suspension system for direct support. (Somas aSCA sere rile 2ofles 3-4) - Tandem fixtures may utilize common wires. Mechanical Services - TermhFds or services weighing 20 lbs. but not more than 56 lbs. must have two 12 gage wires connecting them to the ceding system hangers or the structure above. These wires may be slack. (Sources aSCA Seismic tones 3-4) - Terminals or services weighing more than 56 lbs. must be independently supported d rectiy from the structure above. These wires must be taut. (sauce aSCA Seismic zone. 3-4) Seismic Separation Joints (figure 7) - For ceding areas exceeding 2,500 square feet, a seismic separation joint ar full height wall partition that breaks the ceding shdl be provided unless analyses are performed of the ceiings bracing system, closure angles and penetrations to provide sufficient clearance. (scarce ASCE 7-05 Rem 9 a sr a d) - The layout and locution of the seismic separatioil 'pint d he per the designer of record and noted on the plans. If a seismic separation joint is required by the designer, the designer may use the generic joint detailed in this document or a proprietary joint The amount of free movement (gap designs) shdl be a minimum of Y. inch. - In lieu of seismic separation joints. the ceding may be divided into areas less than 2500 square feet by the use of petitions or soffits as follows: partitions shall extend a minimum of 6 itches above the level of the plane of the grid and shag be independently braced to the structure above. Soffits shall extend to a point at least level with the bottom plane of the grid and shall be independently supported and laterally braced to the structure above. - Other than petitions and soffits, seismic joints may not be used as part of a fire rated ceding assembly unless substantiating documentation is provided Sprinklers - For ceilings without rigid bracing, sprinlder head penetrations shall have a 2 inch oversize ring, sleeve or adapter through the ceding tile to allow free movement of at least 1 inch in dl horizontal directions. Flexible head design that can accommodate 1 inch free movement shill be permitted as an alternate. (swank ASCE 7-05 9.8.2.6.22. item e) Suspension Ceiling Installation Requirements Part Notes and Specifications T-1 01710 - FINAL CLEANING Part I- GENERAL 1. The Work induded in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. 2. The final cleaning shall be performed by a professional cleaning company. 3. All surfaces and finishes shall be left free of marks, blemishes, dust, dirt, over spray, paint spills, etc... Part II- PRODUCTS AND MATERIALS 4. CLEANING PRODUCTS a. All products used for cleaning shall be appropriate for and compatible with the materials being cleaned. 5. RESERVED 13. N/A 14. 15. 16. 05 Part I- 1. 2. 3. III- EXECUTION 6. Clean all plastic laminates, countertops and metal trim with non- abrasive cleansers. 7. Clean all glass and mirrors with ammonia -type non - streaking glass cleanser. 8. Damp wipe all fixtures, including light fixtures. 9. Remove labels, except for those required to demonstrate compliance with building codes, fire- ratings and testing. Also remove all residue and glue remaining on the surface. 10. CARPET CLEANING - all carpeting, including base and wall installations, shall be thoroughly vacuumed. Where spotted or stained, carpeting shall be steam cleaned. 11. TOILET ROOMS - all fixtures and washable surfaces in the toilet rooms shall be cleaned, sanitized and polished. 12. ELECTRICAL PANELS AND FLOOR MOUNTED MECHANICAL EQUIP. shall be dusted and wiped clean. VINYL COMPOSITION TILE - strip, wash, seal & wax. AMT1C0 FLOORING- wash, clean and seal per mfr's specifications. Remove protective coverings and tags. Remove and dispose of all trash, scraps, packing etc... Disposal shall be in accordance with the Landlord's requirements. 17. SLATWALL & TRIM - Wipe clean 18. SOFFITS AND VALANCES - Dust Clean 19. CERAMIC TiLE - wash, clean and seal per mfr's specifications. Notes and Specifications 05000 - METALS GENERAL The Work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. Coordinate this Work with the RELATED WORK of others which includes but is not necessarily limited to the following: a. 09000 - FINISHES Furnish and install metal fabrications which include but are not necessarily limited to light gauge metal framing and miscellaneous metals. Part II- PRODUCTS AND MATERIALS N/A Notes and Specifications T 06100 - ROUGH CARPENTRY Part I- 1. 2. 3. 4. Part II- 5. 6. 4. STRUCTURAL STEEL a. Storefront sign support 5. LIGHT -GAUGE METAL FRAMING -ICBO PIER -211 a. Demising Walls - Existing b. interior Partitions - 2 1/2 ", 3 5/8 ", and 6' CR and CS Series metal studs at 12/16' O.C. minimum or as detailed: gauges shall be as shown on the Partition Schedule - Dwg. A-1. c. Interior Soffits - 2 1/2' and 3 5/8" CR and CS Series metal studs 012716" O.C. minimum (25 gauge or as shown on details) d. Bridging- Cross bridging ®6' -O" o.c. vertical max. same stud as vertical members. 6. FASTENERS a. Stud to stud, stud to track, stud to bracing - fasten with (2) -1/8 TEK Screws 0 each connection. b. Track to floor slab - Hilti FDF Series fastener pin ® 4' -O" o.c. (5/8" Penetration .138 Dia.) 7. UNISTRUT SUPPORT SYSTEM FOR VIDEO MONITORS, AND /OR SIGNAGE. 8. SATIN NATURAL WALL ANGLE TRIM AT SLATWALL 9. SATIN NATURAL CORNER GUARDS AT INTERIOR COLUMNS IN SALES AREA. GENERAL The Work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. Coordinate this Work with the RELATED WORK of others which includes but is not necessanly limited to the following: a. 16000 - ELECTRICAL - Backboard Panels. Fumish and install all rough carpentry which includes but is not necessarily limited to rough blocking, panels and backboards. All wood used for framing and blocking shall be fire- retardant treated, tested per ASTM E84 and shall have a flame spread rating not greater than 25. The material shall bear the identification of an authoritative testing or inspection agency. PRODUCTS AND MATERIALS BLOCKING - Nominal 2x, Fire Retardant Treated PLYWOOD - Are Retardant a. Backboards - 3/4* b. Shelving - 3/4 painted plywood c. Substrate - 3/4" Fire Retardant Treated Plywood d. Substrate - 1/2" Fire Retardant Treated Particle Board Notes and Specifications 06200 - FINISH CARPENTRY Part I- GENERAL 1. The Work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. 2 Coordinate this Work with the RELATED WORK of others which includes but is not necessarily limited to the following: a. Color- coated Plastic Glazing, see Spec 08800 b. Rough Carpentry, see Spec 06100 c. Furnishings, see Spec 12000 3. Furnish and install all finished carpentry which includes but not necessarily limited to, shelves, prefinished wood products, wood trims, substrates & plastic laminates shown on the drawings and in related documents. 4. Install items provided by the owner which include display fixtures, slatwall, cash wrap, wall - mounted items and finish hardware as shown on the drawings and in related documents. 5. REFERENCE DOCUMENTS - Reserved 6. All wood used for frnming and blocking shall be fire- retardant treated, tested per ASTM E84 and shall have a flame spread rating not greater than 25. The material shall bear the identification of an authoritative testing or inspection agency. Part II- PRODUCTS AND MATERIALS 7. TOGGLE BOLTS for wall mounted items, equal to "HILTi TOGGLER W/BOLT 0520520 ", shall be provided and installed by the Tenant's Contractor. 8. PLYWOOD - Fire Retardant a. Substrate - 3/4', 1/2' b. Particle Board - 1/2" c. M.D.F. Board - 3/4 ", 1/2" 9. PLASTIC LAMINATE 10. CONTACT ADHESIVE 11. MISC. HARDWARE 12. WOOD TRIM - Poplar, Select Grade Part I- 1. 2. 3. 4. 5. Part II- PRODUCTS 6. MANUFACTURER shall be an approved equal to Metro Door, PBG 7. GUIDES - clear anodized 8. BOTTOM BAR - clear anodized 9. LOCKING CYLINDERS - On mall side 10. CURTAIN - Mill finish aluminum, M -9 Series 11. THUMB TURN - On Tenant side 12. MOTOR - Vertical bracket mounted grille motor 13. MINI KEY SWITCH - (brushed aluminum cover plate) one on Tenant side and one on mall side 12* A.F.F. (See Sht. A -1.1 for locations) Switch cover plate to be 2 7/8 "w x 4 1/2"h N/A 14. EMERGENCY RELEASE - Mount to store side of grille tube enclosure at height required by code. 48" A.F.F. Part III- INSTALLATION 15. Anchor new system for structural Toads in accordance with building code requirements. N/A N/A o8 Part I- 1. 2. 3. 4. Notes and Specifications 08300 - ROLL -UP GRILLE GENERAL The Work included in this subcontract shall be performed according to the General Conditions and requirements which are stated on the cover sheet of this set of drawings. SUBMITTALS - Shop drawings shall be submitted for approval by the landlord if a substitution is made. Furnish and install all materials, hardware and labor required to provide a complete roll -up grille system fully integrated with the Work of other trades. Reserved APPLICABLE CODES: Install Roll -Up Grille per National, State, and Local Codes Notes and Specifications 08410 - STOREFRONT GLAZING SYSTEM GENERAL The Work included in this subcontract shall be performed according to the General Conditions and requirements which are stated on the cover sheet of this set of drawings. Provide and install all glazing and miscellaneous accessories as required to complete the Work of this section. SAFETY STANDARDS - New glazing materials shall comply with CPSC 16 -CFR Part 1201; 42FR1428. APPLICABLE CODES: Glazing shall comply with National, State and Local Codes. Part II- PRODUCTS 5. MONOLITHIC HEAT - TREATED GLASS -1/2" clear tempered float glass which has been heat strengthened accordance with Federal Specification ASTM C1048. All visible edges shall be beveled and smooth. (As Noted on Drawings) 6. MISC. GLAZING ACCESSORIES: a. SETTING BLOCK, or match existing b. No Caulking or Silicon is allowed between sections of glazing c. GLAZING VINYL - For 1/2* thick glazing - black #226025 (inside), #226024 (outside) d. GLAZING CHANNEL - AT BASE - 6* high x 2' wide Stylmark 110481 Satin Natural #020 w/ 110358 anchor or equal. e. GLAZING CHANNEL - AT HEAD - 1 3/4" high x 2' wide Stylmark 110483 Satin Natural #020 or approved equal. f. GLAZING CLIPS - Guardian 3* Square, 15', 30', 45', 60' and 90' - color to match Stylmark Satin Natural #020 or approved equal 9. TRIM BASE - 6 "H x 3/4 "W Rectangular Trim Base - Stylmark Base # 110269 with Base #410509 Satin Natural #020 or approved equal N/A h. Additional glazing channels cis indicated on storefront sections, if applicable. Part 111- INSTALLATION 7. ANCHOR SECURELY Notes and Specitications 09250 - GYPSUM DRYWALL SYSTEM Part I- GENERAL 1. The Work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. 2. Coordinate this Work with the RELATED WORK of others which includes but is not necessarily limited to the following: a. 05000 - METALS - Light gauge framing b. 06100 - ROUGH CARPENTRY 3. Furnish and install all drywall materials, accessories and products required to provide a complete installation, including, but not limited to gypsum drywall on existing demising walls, interior partitions, soffits, fascias and gypsum wallboard used as substrates for other materials. 4. Repair and patch existing gypsum drywall system. 5. Application procedures and workmanship shall be in accordance with GA -216 and ASTM C840. Part II- PRODUCTS AND MATERIALS 6. GYPSUM DRYWALL PANELS a. Fire Resistant - 5/8' thick with a Type X core; equal to Gold Bond Fire- Shield with Sta- Smooth edges. b. Moisture Resistant - for application in wet areas and for use as a substrate for areas designated to receive ceramic tile, nonabsorbent finish materials and similar products, use 5/8* thick gypsum wallboard equal to Gold Bond MR Fire- Shield G with green paper faces and tapered edges. 7. JOINT TREATMENT a. Joint Tape - paper b. Joint Compound - fast hardening type equal to Gold Bond Sta- Smooth. 8. ACCESSORIES a. Corner Beads - 1 -1/8 "x 1 -1/8" galvanized metal, crimped to all wall board corners. b. Comer Beads - 1 -1/4 "x 1 -1/4" galvanized metal for double layered walls. c. Casing Beads - galvanized metal. Part III- FABRICATION AND INSTALLATION 9. Install system free of waves, buckles and unevenness. 10. EXPOSED TO VIEW - all joints, holes and depressions visible below the ceiling line shall be filled, floated, sanded smooth and made ready to receive paint primer. 11. CONCEALED LOCATIONS - all joints, holes and depressions concealed above ceiling lines and behind permanent fixtures shall be filled and taped. 12. EXTENT ABOVE CEILINGS - gypsum wallboard shall extend a minimum of 4 above the adjacent ceiling line. At demising walls, draft stop partitions and fire - separation walls, the gypsum wallboard shall extend fully to the underside of the structural deck above. ofr //c 1■9 Notes and Specifications T - 09510 - GYPSUM BOARD CEILINGS Part I- GENERAL 1. The work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. 2. All ceilings to bear one hour minimum U.L rating installed in strict compliance with manufacturer's published specifications and current Bulletin of Acoustical Materials Association - job conditions (If required by code). Suspension system for gypsum ceilings; rigid ceiling grid system with cross furring channels, direct suspension system by United States Gypsum or drywall suspension system by Donn Corporation. • .4. Access doors shall be provided to all control devices, dampers, and the mixed air discharge and intake plenums and the HVAC unit. 5. Access doors in suspended drywall ceilings and walls to be pan shaped, and painted to match adjacent finish. Install Karp DSC -214M, 24* x 24 ", Universal flush metal access doors in non fire rated partitions and ceilings. Install #(RP- 150FR, 24" x 24 ", Universal flush metal access doors in partitions and ceilings requiring a one hour fire rating. See reflected ceiling plan for additional information and location. 09 Notes and Specffications 09900 - PAINTING Part I- GENERAL 1. The work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. 2. General contractor to confirm suitability of all walls to receive paint and /or wall covering in a first class manner. General contractor to contact architect if any walls not acceptable to receive as specified. Poor installation over unsuitable surface is painting contractors responsblity. 3. All surfaces to be primed per manufacturer s recommendations. Suitable and compatible with surface and finish specified. 4. All material workmanship shall produce a first class installation of uniform quality without laps and streaks. 5. All painted surfaces to receive one coat of primer and two coats of finish paint, unless otherwise noted. Note: painted surface to be smooth rolled or brushed with no skips, laps, or streaks. See color schedule for manufacturer's designations. 6. Painting contractor to fill and touch up all nail holes in wood trim. 7. All caulking to match adjacent finish. 1)9 Notes and Specifications T - 09650 - VINYL COMPOSITION TILE/CERAMIC 11LE ■/ FLOOR AND BASE Part I- GENERAL 1. The work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. 2. Vinyl composition tile floors to be properly prepared without holes, cracks and bumps, to insure a first class floor installation. 3. Vinyl composition floor tile and vinyl or rubber base to be as specified on room finish schedule. 4. Vinyl composition floor tile and vinyl rubber base to be installed in accordance with manufacturer's recommendations. 5. Vinyl and rubber base rolled smooth, corners and edges to be true and tight, seam sealer to be applied size of smallest piece to be 8 inch length. All surfaces to be tumed over to owner dean, without mastic smears or seepage. 6. All vinyl and rubber base shall be furnished with preformed inside and outside corners. 7. Concrete floor sealer (if required) - A. Concrete floors to be properly prepared without holes, cracks, bumps, to insure a first class installation. B. Surface must be clean, and free of all wax, grease, and of and dry. C. Concrete sealer is to be applied in accordance with manufacturer s recommendations. 8. PRODUCT DATA: Submit manufacturer's technical information and installation instructions for specified materials, except bulk materials. 9. SAMPLES: Submit mounted floor tile sample for each selected color or specified tiles, grout and accessories requiring color selection. 10. Setting and routing material s+ Provide materials obtained from one source for each type and color of grout and setting. 4,49 Notes and Specifications T 09680 -- CARPET TILE Part I- GENERAL 1. The work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. 2. Floor surface to be properly prepared to produce a substrate with a clean, sound. smooth, and even surface; without holes, cracks, or bumps. Floor leveler recommended by carpet manufacturer to be used. 3. Installation to be glue down method, using Milliken releasable carpet adhesive. Apply adhesive uniformly to substrate in accordance with manufacturer's instructions. 4. Comply with manufacturer's recommendations for tile installation unless otherwise noted on the drawings. 5. Provisions shall be made for proper finishing and trimming of floor plates /access doors in a manner that allows them to remain accessible. 6. Installer shall take care in cutting carpet tight to intersecting vertical surfaces and at transition points. 7. Butt edges of carpet ties tight without gaps. 8. Roll entire area lightly to eliminate air pockets and ensure uniform bond. 9. Carpet to be tumed over to owner dean, without stains or snags, due to construction work. 10. All debris to be removed from premises. All extra full tiles to be protected and stored in stockroom. 11. Install transitions strips at the transition to all hard surface flooring as indicated on drawings. 12. Carpet tile to be installed with one quarter tum pattern so that each tile is laid 90 degrees to all adjacent tiles. 10 Notes and Specifications Part I- 1. z. 3. 4. 10810 TOILET ROOM ACCESSORIES (FURNISHED AND INSTALLED BY T.G.C. UNLESS OTHERWISE NOTED) GENERAL The Work included in this subcontract shall be performed according to the General Conditions and Requirements which are stated on the cover sheet of this set of drawings. Coordinate this Work with the RELATED WORK of others which includes but is not necessanly limited to the following: 06100 - ROUGH CARPENTRY Tenant's Contractor Furnish and install specialties which include but are not necessarily limited to toilet room accessories and miscellaneous items. SUBMITTALS - Product Data sheets for proposed substitution shall be submitted for approval. Part II- PRODUCTS AND MATERIALS 5. TOILET ROOM ACCESSORIES a. Paper Towel Dispenser, Bay West, Furnished by Tenant and Installed by T.G.C. b. Horizontal Grab Bar Bobrick # B -6806 x (1) 36' and (1) 42* Required c. Vertical Grab Bar Bobrick # B -6806 x 18' (1) Required d. Coat hook Bobrick # B -682 at 54* A.F.F. on interior face of door. e. Mirror Bobrick # B- 293 -1836 f. Soap Dispenser Bobrick # B -155 g. Toilet Tissue Dispenser Bobrick # B -273 Part III- INSTALLATION 6. All accessories to be mounted as per applicable accessibility codes. Provide fire retardant blocking in walls as required. RECE +.'f a CITY OF TUKIMLA MAP 032008 PERMIT CENTER PLUMBING FIXTURE SCHEDULE NAP 0 3 7008 PFIRMI rrPki FIXTURE NO. FIXTURE TYPE MANUFACTURER TYPE & MODEL NO. TRIM NO. SUPPORT PIPE SIZES REMARKS _ TRAP WASTE VENT CW HW F -1 WATER CLOSET SIPHON JET AMERICAN STANDARD OR EQUAL CADET (WHITE) 2386.012 CHICAGO FAUCET 1016 FLOOR MOUNT _ 4 " 2 " 1/2 _ WHITE SEAT- CHURCH MODEL 295C 16 -112" RIM HEIGHT FOR ADA COMPLIANCE. PROVIDE INSULATED CAST BRASS P -TRAP, PROVIDE HANDICAP INSULATION KIT. FAUCET SHALL BE METERING SELF CLOSING. MOUNT AT A.D.A. HEIGHT - F -2 LAVATORY AMERICAN STANDARD OR EQUAL LUCERNE (WHITE) 0355.012 CHICAGO FAUCET 802A,327A, & (2)1016 - - WALL HUNG WALL MOUNT 1-1/4* 1_1/4" 1-1/2" 1_1 /2 " 1-1/2" 1_1/2 1/2" 1/2" 1/2" _ F -3 DRINKING FOUNTAIN EI*Y OR EQUAL BARRIER -FREE EDFP-19-C FLOOR DRAIN JOSAM OR EQUAL 30000 -A - - 3" 3" 1 -1 /2" - - PROVIDE DEEP -SEAL TRAP -- PLUMBING SYMBOL LEGEND DRAWING SYMBOL SYMBOL DESCRIPTION A� REDUCED PRESSURE ZONE BACK FLOW PREVENTOR (RPZ) CAPACITY (GAL) PRESSURE REUEF VALVE K51 BALL VALVE III UNION F.C.O. 0 FLOOR CLEAN OUT D ELBOW DOWN S PIPE BREAK .. TEE DOWN e FLOOR DRAIN ELECTRIC WATER HEATER SCHEDULE UNIT NO. MANUFACTURER MODEL KW CAPACITY (GAL) STAGES VOLTAGE OUTPUT (GPH 90' RISE) REMARKS WH -1 A.O. SMITH EJC -6 1.7 6 1 120/1/60 7 NONE PLUMBING PLAN H I-I 1 0 1 2 4 8 FEET F.C.O. C F -1 FD -1 0. PLUMBING SPECIFICATIONS 15000 - GENERAL PROVISIONS 0.01 DEFINITIONS: THE TERMS USTED BELOW ARE DEFINED AS FOLLOWS WHEN USED IN DMSION 15 WORK AND ONLY DMSION 15 WORK. 1. WORK: LABOR AND MATERIALS OF THE CONTRACTOR AND /OR SUBCONTRACTOR. 2. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELVER TO THE JOBSITE IN NEW CONDITION AND GUARANTEE. 3. INSTALL RECEIVE AT THE JOB- -SITE, UNLOAD, STORE, SET IN PLACE, CONNECT, PLACE IN OPERATION AND GUARANTEE. 4. PROVIDE: FURNISH AND INSTALL 5. CONNECT: BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENTS INCLUDING NECESSARY PIPE FITTINGS, DUCTWORK, TRANSITIONS, ETC. 6. CONCEALED: HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, ABOVE CEILING, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES OR BURIED. 7. EXPOSED: NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. 0.02 PERFORMANCE: PLUMBING CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED, INDICATED AND REQUIRED UNLESS OTHERWISE NOTED, INCLUDING FINAL CONNECTIONS, IN A WORKMANUKE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE TRADE. 0.03 SITE EXAMINATION: EXAMINE SITE BEFORE BIDDING. CLAIM NO EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDITIONS. IF SITE CONDITIONS REQUIRE MODIFICATION OF THE SYSTEMS INDICATED IN THESE DOCUMENTS, SO ADVISE ENGINEER, AND IF ACCtr BY ENGINEER, INCLUDE COST OF SUCH MODIFICATIONS IN BID. 0.04 JOBSITE CONDITIONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0.05 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECESSARY FOR A COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.06 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSING, BONDING, AND INSURANCE, AND PERFORM OTHER ADMINISTRATIVE FUNCTIONS, AS REQUIRED. 0.07 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES. 0.08 COORDINATION: CONFORM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HEREIN. REFER ALSO TO STRUCTURAL AND ELECTRICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER TRADES. 0.09 CUTTING AND PATCHING: CUT AND PATCH AS REQUIRED. CUT OR WELD STRUCTURAL MEMBERS ONLY WITH APPROVAL OF STRUCTURAL ENGINEER. PATCHING SUBJECT TO APPROVAL BY ARCHITECT. 0.10 EXISTING FLOORS: TRENCH OR CORE BORE EXISTING FLOORS PER LANDLORD REQUIREMENTS. 0.12 EQUIPMENT SUBSTITUTIONS: REIMBURSE ELECTRICAL CONTRACTOR, AT NO CHARGE TO TENANT, FOR HIS COSTS INCURRED DUE TO SUBSTITUTION OF PLUMBING EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.13 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.14 REFERENCE STANDARDS: COMPLY WITH APPUCABLE STANDARDS OF NFPA, ANSI, UL, ASHRAE, AND SMACNA, EXCEPT AS SUPERSEDED BY LOCAL AUTHORITY. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED CODE MINIMUM REQUIREMENTS. 0.15 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF APPUCABLE CODES, LANDLORD, SERVING UTILITIES, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD, LOCAL AUTHORITY, AND OTHERS AS REQUIRED. 0.16 MATERIALS AND EQUIPMENT: PROVIDE NEW, UL USTED, COMMERCIAL GRADE MATERIALS, DEVICES, EQUIPMENT, AND FIXTURES, SUITABLE FOR ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPLIANT WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION, AND APPROVED BY THE ENGINEER. 0.17 SHOP DRAWINGS: BEFORE ORDERING EQUIPMENT AND MATERIALS, SUBMIT NOT LESS THAN FIVE CERTIFIED COPIES OF ALL SHOP AND EQUIPMENT DRAWINGS FOR ENGINEER'S REVIEW, WHO WILL RETAIN TWO COPIES. ONLY FURNISH SYSTEMS AND EQUIPMENT IN COMPLIANCE WITH ACCEPTED SHOP DRAWINGS. 0.18 INSTALLATION: INSTALL ALL MATERIALS, EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURERS' INSTRUCTIONS. 0.19 LAYOUT: INSTALL ALL PIPING TO PRESENT A NEAT AND ORDERLY APPEARANCE. RUN ALL LINES PARALLEL WITH BUILDING CONSTRUCTION. MAINTAIN HEADROOM AND EQUIPMENT CLEARANCE, AND GRADIENT WHERE REQUIRED. ALLOW FOR EXPANSION AND CONTRACTION. 0.20 ACCESS DOORS: PROVIDE ACCESS DOORS OR PANELS FOR ALL VALVES, CLEANOUTS, DAMPERS, CONTROLS, DEVICES, AND OTHER ITEMS REQUIRING INSPECTION OR MAINTENANCE. ACCESS PANELS SERVING HVAC COMPONENTS SHALL BE 12- INCHES BY 12- INCHES MINIMUM OR LARGER TO PROVIDE SUFFICIENT WORKING CLEARANCE FOR COMPONENT BEING ACCESSED. 1 /4" - 1' -0" 15100 - PIPE AND FITTINGS F.C.O. 2" 'N. 1 1-1/0-42 F.C.O. 2 cp - 1 -1/2" 1 -1/2X I 1- � % 2 u F - _2 WASTE & VENT RISER N.T.S. 0.21 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT AND SUBMIT REPORT TO ENGINEER. 0.22 0 & M MANUALS: AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER OR OPERATOR. THE MANUAL SHALL INCLUDE BASIC DATA RELATING TO THE OPERATION AND MAINTENANCE OF PLUMBING SYSTEMS AND EQUIPMENT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. 0.23 WARRANTY: UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF FINAL ACCEPTANCE. DURING WARRANTY PERIOD, REPAIR OR REPLACE DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP WITHOUT COST TO TENANT. 0.25 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT, PIPE AND DUCT LOCATIONS TO AVOID CONFLICTS WITH OTHER CONSTRUCTION AND TRADES. 0.26 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE THESE SPECIFICATIONS. 0.27 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS AND REQUIREMENTS. 0.28 PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS INCLUDED IN THESE SPECIFICATIONS MAY BE REQUIRED FOR THIS PROJECT. 0.29 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ERRORS, DISCREPANCIES OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE, BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 0.30 AS -BUILT DRAWINGS: SUBMIT AS-BUILT DRAWINGS TO TENANT PRIOR TO FINAL APPLICATION FOR PAYMENT. 1.10 PIPE HANGERS AND SUPPORTS: PROPERLY SUPPORT ALL PIPING FROM JOISTS (TOP CHORD) OR OTHER STRUCTURAL MEMBERS. FOR PIPES UP TO 4" O.D., USE GRINNELL FIG. 260 CLEVIS HANGERS WITH 3/8" ROD, OR FIG. 195 BRACKETS. 1.20 INSULATION SHIELDS: PROVIDE 18 GAUGE X 12" LONG GALVANIZED INSULATION SHIELDS AT SUPPORT POINTS FOR INSULATED PIPES. 1.30 PIPE SUPPORT SPACING: SUPPORT PIPE NOT LESS THAN 6 FT. ON CENTER FOR COPPER PIPE UP TO 2 0.D., OR NOT LESS THAN 10 FT. ON CENTER FOR STEEL PIPE UP TO 4" O.D. 1.40 COPPER CONTACT: PROVIDE COPPER PLATED HANGERS AND SUPPORTS WHERE IN CONTACT WITH COPPER PIPE. 1.50 PIPE SLEEVES: SLEEVE ALL HORIZONTAL PIPING WHICH PENETRATES WALLS WITH STANDARD WEIGHT SIi±L PIPE OF 1" GREATER DIAMETER THAN PIPE OR INSULATION O.D. CUT SLEEVE FLUSH WITH WALL FINISH BOTH SIDES. 1.60 SEALANT: SEAL PIPE SLEEVES WITH ROPE AND EXPAND() NON-SHRINK SEALANT. FIRE /SMOKE SEAL PENETRATIONS OF RATED CONSTRUCTION TO MAINTAIN RATING. 1.70 WALL PLATES: FIT UNCOVERED PIPE PASSING THROUGH WALLS WITH WALL PLATES, CRANE NO. 10 OR EQUAL 15200 - THERMAL AND ACOUSTIC INSULATION 2.30 INSULATION REQUIREMENTS: INSULATE SYSTEMS AS SPECIFIED ONLY AFTER THEY HAVE BEEN TESTED AND INSPECTED. CLEAN ALL SURFACES THOROUGHLY OF MOISTURE, FOREIGN MATERIAL, GREASE, AND RUST. INSTALL INSULATION CONTINUOUS THROUGH PENETRATIONS. 2.31 INSULATION HAZARDS: USE ONLY INSULATION ADHESIVES, SEALERS, AND COATINGS WFEH FIRE HAZARD RATING NOT TO EXCEED 25/50/50 FLAME SPREAD, FUEL CONTRIBUTED, AND SMOKE DEVELOPED, IN ACCORDANCE WITH UL 723 AND ASTM E84. 2.32 INSULATED PLUMBING SYSTEMS: INSULATE HOT AND COLD WATER PIPING, AND HORIZONTAL WASTE PIPING IN CEIUNG SPACE, WITH 1 -IN. THICK (MIN. R -4) CLOSED CELL, SELF SEALING FLEXIBLE TUBING, ARMAFLEX 2000 OR EQUAL 15400 - PLUMBING D ) CHECK VALVE UP TO 3" GLOBE VALVE UP TO 3" GATE VALVE UP TO 3' BALL VALVE UP TO 3" TEMP. & PRESS. REUEF VALVE SHOCKSTOP BACKFLOW PREVENTER VACUUM RELIEF VALVE PRESSURE REDUCING VALVE P -1 P -1 �.� i " 3 / 4 1 .I� 1/2" > re" X1/2 WATER RISER 4.10 DOMESTIC (POTABLE) WATER SUPPLY PIPING: ABOVE GROUND: TYPE L HARD TEMPER COPPER TUBE PER ASTM 888, WITH WROUGHT COPPER FITTINGS PER USASI B16.18 AND .18A. BELOW GROUND: TYPE K SOFT TEMPER COPPER TUBE. USE ONLY 95/5 LEAD -FREE SOLDER IN POTABLE WATER PIPING. PROVIDE DIELECTRIC UNIONS AT EVERY JUNCTION OF TWO DISSIMILAR METAL PIPE MATERIALS. 4.20 DRAIN, WASTE AND VENT PIPING: ABOVE GRADE NO -HUB CAST IRON SANITARY SYSTEM PER CISPI 301 -69T OR SCREWED GALVANIZED PIPE WITH CAST IRON DRAINAGE FITTINGS. BELOW GRADE: NO -HUB CAST IRON SANITARY SYS I LM PER CISPI 301 -69T OR SERVICE WEIGHT CAST IRON HUB AND SPIGOT WITH NEOPRENE GASKET, PER CISPI HSN --68T. 4.40 VALVES: FURNISH AND INSTALL VALVES WHERE INDICATED ON PLAN AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. PROVIDE VALVES RATED FOR 125 PSI OR GREATER WORKING PRESSURE IN WATER PIPING. CRANE NO. 37, OR EQUAL CRANE NO. 1, 17TF, OR EQUAL CRANE NO. 428, 1334, OR EQUAL APOLLO SERIES 70 -100, 70 -200, OR EQUAL WATTS 10L MODEL M7, OR EQUAL, 3/4"M X 3/4" F WADE W -5 (HOT), WADE W -10 (COLD) WATTS NO. 9BD, OR EQUAL WATTS NO. N36 - 3/4 ", OR EQUAL WATTS NO. U5 SERIES 4.70 PLUMBING FIXTURES: FURNISH AND INSTALL COMPLETE WITH FITTINGS AND ACCESSORIES AS REQUIRED. SEE PLUMBING FIXTURE SCHEDULE FOR MORE INFORMATION. 4.80 TANK WATER HEATER: A.O. SMITH MODEL EJC -6, OR APPROVED EQUAL, ELECTRIC WATER HEATER, 6 GALLON CAPACITY, RATED AT 120/1/60 AC, 1700 WATTS. MOUNT HEATER ON PLATFORM ABOVE WASHROOM CEIUNG. PROVIDE 4" DEEP WATERTIGHT DRIP PAN, 2" LARGER THAN WATER HEATER ALL AROUND. PROVIDE 1" DRAIN FROM RELIEF VALVE TO DRIP PAN AND 1 " DRAIN FROM DRIP PAN TO DISCHARGE TO FLOOR DRAIN WITH 90 DEGREE ELL TURNED DOWN. 4.95 CLEANING AND TESTING: CLEAN, DISINFECT, AND TEST ALL PLUMBING AND PIPING SYSTEMS. N.T.S. N. 3/4" DRAIN TO NEARBY FLOOR DRAIN. ASME RATED T &P REUEF VALVE. PIPE TO DRAIN PAN. 4 r1 PLUMBING KEY NOTES 1. EXTEND AND CONNECT 4" UNDER FLOOR SANITARY TO LANDLORD'S MINIMUM 4" UNDER FLOOR SANITARY. 2. EXTEND AND CONNECT 2" VENT TO LANDLORD'S MINIMUM 2" VENT PIPING. COORDINATE ROUTING AND POINT OF CONNECTION WITH LANDLORD'S FIELD REPRESENTATIVE. 3. EXTEND AND CONNECT 3/4" COLD WATER TO LANDLORD'S MINIMUM 3/4" COLD WATER CONNECTION. PROVIDE ISOLATION VALVE AT EACH FIXTURE AND AT POINT OF CONNECTION TO LANDLORD'S COLD WATER MAIN. COORDINATE ROUTING AND POINT OF CONNECTION IN FIELD. REUSE EXISTING CONNECTION POINT IF POSSIBLE. 4. INSTALL ELECTRIC WATER HEATER ON PLATFORM ABOVE TOILET ROOM. PROVIDE ASME RATED T &P RELIEF VALVE PIPED TO DRAIN PAN. EXTEND SECONDARY DRAIN PIPE FROM DRAIN PAN TO TERMINATE AT FLOOR DRAIN WITH 90' ELL TURNED DOWN. 5. PROVIDE HUB DRAIN FROM RPZ AND EXTEND 1 PIPING TO FLOOR DRAIN. PROVIDE PROPER AIR GAP. VERIFY ROUTING IN FIELD. 6. G.C. TO PROVIDE A CUP DISPENSER IN AN ACCESSIBLE LOCATION IN THE VICINITY OF THE DRINKING FOUNTAIN. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 7. INSTALL SHUT -OFF VALVE AT EYE LEVEL IN TOILET ROOM. VERIFY EXACT REQUIREMENTS WITH LANDLORD'S FIELD REPRESENTATIVE. it li III iii III Dob-llc RECErv SEPARATE TOILET FACILITIES FOR BOTH GENDERS ARE NOT REQUIRED AS THE MALL HAS PROVIDED CENTRALLY LOCATED PUBLIC ACCESSIBLE RESTROOMS AND DRINKING WATER FOUNTAIN WITHIN 300 FEET OF THIS SPACE. TENANT TOILET ROOM DOES NOT HAVE TO BE ACCESSIBLE TO THE PUBLIC. LINETYPE LEGEND - - - - - - DOMESTIC COLD WATER - - - - - - - - - DOMESTIC HOT WATER SANITARY SEWER (ABOVE FLOOR /GRADE) SANITARY SEWER (BELOW FLOOR /GRADE) VENT VERIFY ALL CONDITIONS IN FIELD GENERAL PLUMBING NOTES A ALL EQUIPMENT, INSTALLATION AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING STUB -INS, TAPS, ETC. FOR PLUMBING SYSItMS WITHIN TENANT SPACE. C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE LANDLORD'S BASE SYSTEMS. COORDINATE ALL SYSTEMS IN FIELD. D. REMOVE ALL EXISTING PLUMBING FIXTURES, PIPING SYSTEMS, ETC. NOT BEING REUSED. DO NOT JUST ABANDON. CITY OF TUKVALA 0 0 Z m 0 O w • CO W g 0 0 zzw W of z I,a1 W D0 Ca U Cn 0 W cn 3�3 0 C9 Z Z CO Q M J CL 0_ Es el IRE 11011 a M WI A Op OD g SHEET NUMBER P -1 SHEET 11 OF 17 HVAC SYMBOL LEGEND DRAWING SYMBOL OL DESCRIPTION MODEL CEIUNG DIFFUSER - TYPE- RUNOUT AND PRIMARY AIR AIL A-XX 300 NECK SIZE CFM N.C. UNIT WEIGHT (LBS) RETURN EXHAUST - TYPE -SIZE MIN. CFM NI C- 180 GRILLE/REGISTER CFM VOLTAGE CAPACITY (KW) BRANCH DUCT SPIN -IN FITTING VAV -1 TRANE VPEF12 ROUND ELBOW 1800 TRANSITION 4 1 ._T ---1 �1 MANUAL VOLUME DAMPER _.._._ -_._.. ._... FLEXIBLE DUCTWORK - 5'-0" MAX. Q REVISION TRIANGLE 0.05 0.05 POINT OF CONNECTION NEW TO EXISTING aT THERMOSTAT --� -� RETURN /EXHAUST AIR VPEF12 EXISTING HVAC — -- ---- — 550 NEW DUCTWORK 0.5 0 KEY NOTE PARALLEL FAN POWERED V.A.V. BOX (WITH ELECTRIC HEATING COIL) SCHEDULE UNIT NO. MANUF. MODEL PRIMARY AIR INLET SIZE (IN.) PRIMARY AIR HEATING CFM FAN MOTOR DATA HEATING COIL DATA MAX. ALLOWED S.P. DROP (IN. W.C.) * DOWNSTREAM TOTAL S.P. IN. W.C. N.C. UNIT WEIGHT (LBS) MAX. CFM MIN. CFM EXT. S.P. (IN. W.C.) FAN H.P. VOLTAGE CAPACITY (KW) VOLTAGE VAV -1 TRANE VPEF12 12" DIA. 1800 550 1100 0.5 1/3 1/3 277/1/60 277/1 /60 5.0 5.0 480/3160 480[3/ 0.05 0.05 0.5 0.5 27 27 115 115 VAV -2 TRANE VPEF12 12" DIA. 1800 550 1100 0.5 * - THIS INCLUDES THE LOSS FOR THE VAV BOX AND THE HEATING COIL OUTSIDE AIR NOTE: THIS TENANT HAS NO CONTROL OVER THE AMOUNT OR PROPORTION OF OUTSIDE AIR DEUVERED TO THIS LEASED SPACE. ALL OUTSIDE AIR FOR THIS SYSTEM IS SUPPLIED BY THE LANDLORD'S CENTRAL VAV SYSTEM. AS SUCH IT IS THE LANDLORD'S SOLE RESPONSIBILITY TO ENSURE THE CODE- REQUIRED MINIMUM OUTSIDE AIR IS DELIVERED TO THE TENANTS SPACE DURING NORMAL MALL HOURS OF OPERATION. SCHEDULE OF DIFFUSERS, REGISTERS AND GRILLES UNIT NO. MANUFACTURER MODEL SIZE OF DIFFUSER NOTES A TFfUS TMS 24" X 24" 1 B TITUS 50F 24" X 24" 2 c TITUS 50F 24" X 12 2 NOTES: 1. SUPPLY AIR DIFFUSER WITH OPPOSED BLADE DAMPER. 2. 1/2- X 1/2- X 1/2" EGGCRATE RETURN AIR GRILLE. c _ - T I or -- I 1 1 A -10 150 1/2" ROD (TYPICAL) PRIMARY SUPPLY AIR DUCT ANCHOR TO STEEL BEAM OR TOP CHORD OF BAR JOIST AT PIN POINT (TYP) T TRANSVERSE RESTRAINTS (TYP OF 4) NOTE: 45' PROVIDE LONGITUDINAL AND TRANSVERSE RESTRAINTS TO COMPLY WITH 2006 IBC REQUIREMENTS FOR SEISMIC ZONE 'D'. A -10 350 A -,10 350 Jr 45' 2 MOUNTING DETAIL M 1 N.T.S. 18/16 LONGITUDINAL RESTRAINTS (TYP OF 4) • LONGITUDINAL RESTRAINTS (TYP OF 4) 7 • ` 2 J SPRING VIBRATION ISOLATORS (TYPICAL) VAV BOX FLEX DUCT CONNECTION (TYPICAL) MD021 1Q/16 1: 7 A -10 350 A -10 350 INSTALL B22 STRUT EACH SIDE N.T.S. MECHANICAL KEY NOTES 1. NEW VAV BOX. PROVIDE MINIMUM 4 EQUIVALENT DIAMETERS OF STRAIGHT DUCT IMMEDIATELY UPSTREAM OF VAV BOX. MEDIUM PRESSURE DUCT UPSTREAM OF VAV BOX TO BE "PITTSBURGH LOCK" AND CONSTRUCTED TO 6" PRESSURE CLASSIFICATION PER SMACNA. 2. LOCATE VAV BOX IN BEST POSSIBLE LOCATION. LOCATION ON DRAWING IS APPROXIMATE ONLY. ABIDE BY MANUFACTURER'S CLEARANCE RECOMMENDATIONS. HANG FROM STRUCTURE ABOVE WITH VIBRATION ISOLATORS. 3. EXTEND AND CONNECT NEW SUPPLY AIR DUCTWORK OF SAME SIZE TO EXISTING LANDLORD SUPPLY AIR DUCTWORK. VERIFY EXACT LOCATION, SIZE AND ELEVATION IN FIELD. 4. T -STAT - MOUNT AT 4' -6" A.F.F. 5. RETURN AIR TO EXIT SPACE THROUGH 6" OPENING ABOVE DEMISING WALLS. 6. SEE PLUMBING PLAN AND RISER DIAGRAMS ON SHEET M -2 FOR PLUMBING WORK IN THIS AREA. 7. FAN /LIGHT COMBINATION WITH INTEGRAL BACKDRAFT DAMPER BY ELECTRICAL CONTRACTOR. DUCTWORK BY MECHANICAL CONTRACTOR. 100 CFM. 8. EXTEND 6 "o EXHAUST DUCT AND CONNECT TO LANDLORD'S TOILET EXHAUST MAIN. COORDINATE ROUTING W EI LANDLORD'S REPRESENTATIVE. 9. LANDLORD'S EXISTING TOILET EXHAUST DUCTWORK TO REMAIN. 10. LANDLORD'S EXISTING SUPPLY AIR DUCTWORK TO REMAIN. 11 ANCHOR TO STEEL BEAM OR TOP CHORD OF BAR JOIST AT PIN POINT MAX. LENGTH 9' -4" ALL CHANNEL STRUTS AND ATTACHMENTS BY B-UNE OR APPROVED EQUAL. PROVIDE TRANSVERSE BRACING OF DUCTWORK GREATER THAN 728 SQ. IN. ® 20' -0" O.C. AND LONGITUDINAL BRACING 0 40' -0" 0.C. SUSPENDED DUCTWORK DETAIL TWO HOLE OPEN ANGLE M405 HVAC CONTROLS THERMOSTAT HONEYWELL T7350D WITH TG511 VERSAGUARD CLEAR LOCKING COVER, OR APPROVED EQUAL, 7 -DAY PROGRAMMABLE MULTI -STAGE HEATING/COOUNG AUTOMATIC CHANGEOVER THERMOSTAT WITH NIGHT SETBACK CAPABILITIES TO CONTROL THE OPERATION OF EACH UNIT. THERMOSTAT TO HAVE INTEGRAL TEMPERATURE DEADBAND AND START OPTIMIZATION. MOUNT THERMOSTAT AT 4'--6" A.F.F. SEQUENCE OF OPERATION PARALLEL TYPE FAN - POWERED VARIABLE AIR VOLUME SYSTEM, COOLING WITH ELECTRIC HEAT: COOUNG CYCLE - OCCUPIED HOURS: THE THERMOSTAT SHALL MODULATE THE VARIABLE AIR VOLUME CONTROL DAMPER BETWEEN MINIMUM AND MAXIMUM POSITIONS AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE OCCUPIED COOUNG SETPOINT OF THE THERMOSTAT. THE FAN SHALL BE DE-ENERGIZED. HEATING CYCLE - OCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE OCCUPIED HEATING SETPOINT OF THE THERMOSTAT, AND WITH THE VARIABLE AIR VOLUME CONTROL DAMPER IN THE MINIMUM POSITION, THE FAN SHALL OPERATE AND THE ELECTRIC HEATING COIL SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. COOUNG CYCLE - UNOCCUPIED HOURS: THE VARIABLE AIR VOLUME CONTROL DAMPER SHALL BE CLOSED AND THE FAN SHALL BE DE- ENERGIZED. HEATING CYCLE - UNOCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE UNOCCUPIED HEATING SETPOINT OF THE THERMOSTAT, AND WITH THE VARIABLE AIR VOLUME CONTROL DAMPER CLOSED, THE FAN AND THE ELECTRIC HEATING COIL SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. H H 0 1 2 4 8 FEET MECHANICAL PLAN B 1*- A-10 320 1/4" = 1' -0" A -10 320 17 I !1i NOTE TO GENERAL CONTRACTOR: THE EQUIPMENT SPECIFIED FOR THIS PROJECT SHALL BE PURCHASED THROUGH A NATIONAL ACCOUNT WITH TRANE. GENERAL CONTRACTOR OR THEIR MECHANICAL SUB - CONTRACTOR SHALL CONTACT: TRANE NATIONAL ACCOUNTS SARAH MICELI (518) 785 -1315 X 1413 FOR ORDERING AND SHIPPING DETAILS WITHIN THE FIRST WEEK OF CONSTRUCTION. GENERAL MECHANICAL NOTES A. THESE DRAWINGS ARE SCHEMATIC IN CHARACTER AND MUST NOT BE SCALED. THE CONTRACTOR SHALL FIT THE WORK TO THE JOB, CAREFULLY INVESTIGATING THE STRUCTURAL, ELECTRICAL, ARCHITECTURAL SPACES AND FINISH CONDITIONS AFFECTING THE WORK ACCORDINGLY AND FURNISHING NECESSARY BENDS, OFFSETS, AND FITTINGS, JUNCTIONS ETC., WHETHER OR NOT SPECIFICALLY SHOWN OR CALLED FOR, AND SEE THAT THERE ARE NO INTERFERENCES BETWEEN THIS WORK AND THE WORK OF ANY OTHER TRADE. B. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DMSIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL HIS SUBCONTRACTORS WITH ALL OTHER DMSIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. C. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY CODE. D. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURERS' INSTRUCTIONS, THE CONTRACT DOCUMENTS, AND APPLICABLE CODES AND REGULATIONS. E. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, CML, ELECTRICAL WORK, ETC., SHOWN OR SPECIFIED ON OTHER CONTRACT DOCUMENTS. F. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS THAT ARE NOT DIMENSIONED ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS SHALL BE BASED UPON PROJECT SITE CONDITIONS. DO NOT SCALE DRAWINGS. G. ALL EQUIPMENT, PIPING AND DUCTWORK NOT BEING USED OR SHOWN TO REMAIN SHALL BE FULLY REMOVED AND NOT ABANDONED IN PLACE. H. ALL EQUIPMENT, INSTALLATIONS AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA. I. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE LANDLORD'S BASE BUILDING SYSTEMS AS APPLICABLE, AND FOR FIELD VERIFYING, PRIOR TO FINAL BID, ALL EXISTING STUB -INS, TAPS, ETC. FOR MECHANICAL SYSTEMS WITHIN TENANT'S SPACE. COORDINATE ALL SYSTEMS IN FIELD. J. NO FIBERGLASS DUCTBOARD ALLOWED. K. COORDINATE DIFFUSER, REGIS I Llt, AND GRILLE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS, LIGHTING, AND OTHER CEIUNG ITEMS AND MAKE MINOR DUCT MODIFICATIONS AS NECESSARY. L BRANCH DUCT RUNOUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS SHOWN OTHERWISE M. CONTRACTOR SHALL BALANCE ALL HVAC SYSTEMS PER SECTION 15950 IN THE MECHANICAL SPECIFICATIONS. N. ALL EQUIPMENT SUPPORT AND DUCTWORK BRACING SHALL COMPLY WMH 2006 IBC REQUIREMENTS FOR LATERAL AND VERTICAL RESTRAINT IN SEISMIC ZONE 'D'. VERIFY ALL CONDITIONS IN FIELD U � 1 1 W a A C4 m 0 Z ♦:LI 0 rn c3 L T, z W 5 - r^ Z V J Ltl n U Z � N R] U 0 0 r7 CO I II 1. 1 m RECEIVED TTY OF TUKWILA MAP 0 3 2008 PE MIT CENTER ea SHEET NUMBER M -1 SHEET 12 OF 17 SPRINKLER SYMBOL LEGEND DRAWING DESCRIPTION + SEMI— RECESSED HEAD • CONCEALED HEAD 0 PENDANT HEAD '.. + + L r 1! SPRINKLER KEY NOTES ® 1. PENDANT TYPE SPRINKLER HEAD WITH POUSHED CHROME HEAD IN TOILET ROOM. ROUTE SPRINKLER PIPE ALONG FULL HEIGHT WALL SO AS NOT TO IMPEDE USE OF PLATFORM. 2. EXISTING LANDLORD SPRINKLER MAIN TO REMAIN. SHOWN FOR REFERENCE ONLY. VERIFY EXACT LOCATION AND HEIGHT IN FIELD. 3. INSTALL RECESSED TYPE SPRINKLER HEADS WITH POUSHED CHROME FINISH IN LAY —IN CEIUNG IN SALES AREA. 4. INSTALL PENDANT TYPE SPRINKLER HEAD WITH POUSHED CHROME FINISH IN STOCK ROOM AND EGRESS CORRIDOR CEILING. 5. INSTALL PENDANT TYPE SPRINKLER HEAD WITH POUSHED CHROME FINISH IN LAY—IN CEILING TILE ABOVE TOILET ROOM PLATFORM. 6. INSTALL CONCEALED SPRINKLER HEADS WITH WHITE COVER IN GYP. BOARD CEIUNG AT STOREFRONT AND SOFFITS. II If _ _11 I VERIFY ALL CONDITIONS IN FIELD + + O t; L + + + NOTE; FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. • NOTE: REFER TO ARCHITECTURAL REFLECTED CEIUNG PLAN TO COORDINATE EXACT LOCATION OF CEILING FIXTURES. IF DISCREPANCIES EXIST BETWEEN THIS SHEET AND ARCHITECTURAL REFLECTED CEIUNG PLAN, ARCHITECTURAL REFLECTED CEIUNG PLAN WILL TAKE PRECEDENCE. SPRINKLER HEAD LAYOUT IS FOR CONCEPT AND BIDDING PURPOSES ONLY. FIELD VERIFY TYPE AND LOCATION OF SPRINKLER HEADS. LANDLORD'S FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL LAYOUT, HYDRAUUCALLY CALCULATED PIPE SIZES, ALL LOCAL CODES, AND LANDLORD'S CRITERIA AT TENANT CONTRACTOR'S EXPENSE. CONNECTION TO LANDLORD SPRINKLER SYSTEM MAIN PIPING SHALL BE SCHEDULED IN ADVANCE WITH LANDLORD'S FIELD REPRESENTATIVE. REFER TO ARCH. REFLECTED CEIUNG PLAN FOR CEIUNG HEIGHTS. SPRINKLER WORK TO BE PERFORMED BY LANDLORD DESIGNATED CONTRACTOR A THE TENANT'S CONTRACTOR'S EXPENSE. VERY IMPORTANT THE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE LANDLORD, LANDLORD'S FIRE INSURANCE UNDERWRITER, AND ALL GOVERNMENTAL AGENCIES AND AUTHORITIES HAVING JURISDICTION OVER THE PREMISES. H I-I 0 1 2 4 • • 11 I I I Il SPRINKLER PLAN 8 FEET DO311 1/4" = 1' -0" SPRINKLER NOTES SPRINKLER HEADS IN GYPSUM BOARD CEILING IN SALES AREA TO BE CONCEALED TYPE SPRINKLER HEADS IN LAY —IN CEILINGS IN SALES AREA TO BE SEMI — RECESSED TYPE AND CENTERED IN CEILING TILES WHEREVER POSSIBLE. SPRINKLER HEADS IN STOCK AREA AND TOILET ROOM CEILINGS TO BE PENDANT TYPE THERE IS AN EXISTING SPRINKLER SYSTEM AND HEAD LAYOUT WITHIN THE TENANT PREMISES. LANDLORD'S SPRINKLER CONTRACTOR IS RESPONSIBLE FOR DESIGN COORDINATION AND ANY REQUIRED MODIFICATIONS OF SPRINKLER SYSTEM TO FIT NEW CEILING LAYOUT AND TO AVOID CONFLICT WITH OTHER TRADES. ALL SPRINKLER WORK IS TO BE PERFORMED BY LANDLORD'S SPRINKLER CONTRACTOR AT TENANT CONTRACTOR'S EXPENSE. COMBUSTIBLES SHALL NOT BE INTRODUCED UNTIL FULL SPRINKLER SYSTEM IS IN SERVICE. NO COMBUSTIBLES, INCLUDING FIRE — RETARDANT WOOD, SHALL BE INTRODUCED ABOVE THE TENANT'S ACOUSTICAL TILE CEIUNG. FIRE EXTINGUISHING DEVICES AS REQUIRED BY CODES, LOCAL AUTHORITIES, TENANT'S INSURANCE CARRIER, AND LANDLORD'S INSURANCE CARRIER, SHALL BE FURNISHED AND INSTALLED AT TENANT CONTRACTOR'S EXPENSE. THE TENANT'S GENERAL CONTRACTOR SHALL HAVE A FIRE EXTINGUISHER ON SITE AT ALL TIME DURING THE ENTIRE CONSTRUCTION PERIOD. IMPORTANT ALL FIRE PROTECTION SPRINKLER HEADS IN TENANT SPACE MUST BE QUICK RESPONSE (OR) TYPE. 0 z m 0 CC • o U W ZZ W 5 -z v i Ch Z _ I— w U � Q to O U 0 rgt&icrl 1Y1Y1 RECEIVED CITY OF TUKWILA MAR 0 3 2008 ERMIT CENTER ket M m I SHEET NUMBER M SHEET 13 OF 17 MECHANICAL SPECIFICATIONS 15000 - GENERAL PROVISIONS 0.01 DEFINITIONS: THE TERMS US LL) BELOW ARE DEFINED AS FOLLOWS WHEN USED IN DMSION 15 WORK AND ONLY DMSION 15 WORK. 1. WORK: LABOR AND MATERIALS OF THE CONTRACTOR AND /OR SUBCONTRACTOR. 2. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELIVER TO THE JOBSITE IN NEW CONDITION AND GUARANTEE. 3. INSTALL: RECEIVE AT THE JOB -SITE UNLOAD, STORE, SET IN PLACE, CONNECT, PLACE IN OPERATION AND GUARANTEE. 4. PROVIDE FURNISH AND INSTALL 5. CONNECT: BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENTS INCLUDING NECESSARY PIPE FITTINGS, DUCTWORK, TRANSITIONS, ETC. 6. CONCEALED: HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, ABOVE CEIUNG, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES OR BURIED. 7. EXPOSED: NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. 0.02 PERFORMANCE: MECHANICAL CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED, INDICATED AND REQUIRED UNLESS OTHERWISE NOTED, INCLUDING FINAL CONNECTIONS, IN A WORKMANLIKE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE TRADE. 0.03 SITE EXAMINATION: EXAMINE SITE BEFORE BIDDING. CLAIM NO EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDITIONS. IF SITE CONDITIONS REQUIRE MODIFICATION OF THE SYSTEMS INDICATED IN THESE DOCUMENTS, SO ADVISE ENGINEER, AND IF ACCEPTED BY ENGINEER, INCLUDE COST OF SUCH MODIFICATIONS IN BID. 0.04 JOBSITE CONDITIONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0.05 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECESSARY FOR A COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.06 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSING, BONDING, AND INSURANCE, AND PERFORM OTHER ADMINISTRATIVE FUNCTIONS, AS REQUIRED. 0.07 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES. 0.08 COORDINATION: CONFORM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HEREIN. REFER ALSO TO STRUCTURAL AND ELECTRICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER TRADES. 0.09 CUTTING AND PATCHING: CUT AND PATCH AS REQUIRED. CUT OR WELD STRUCTURAL MEMBERS ONLY WITH APPROVAL OF STRUCTURAL ENGINEER. PATCHING SUBJECT TO APPROVAL BY ARCHITECT. 0.10 EXISTING FLOORS: TRENCH OR CORE BORE EXISTING FLOORS PER LANDLORD REQUIREMENTS. 0.11 ROOF PENETRATIONS: COORDINATE WITH LANDLORD. 0.12 EQUIPMENT SUBSTITUTIONS: REIMBURSE ELECTRICAL CONTRACTOR, AT NO CHARGE TO TENANT, FOR HIS COSTS INCURRED DUE TO SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.13 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.14 REFERENCE STANDARDS: COMPLY WITH APPUCABLE STANDARDS OF NFPA, ANSI, UL, ASHRAE, AND SMACNA, EXCEPT AS SUPERSEDED BY LOCAL AUTHORITY. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED CODE MINIMUM REQUIREMENTS. 0.15 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES, LANDLORD, SERVING UTILITIES, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD, LOCAL AUTHORITY, AND OTHERS AS REQUIRED. 0.16 MATERIALS AND EQUIPMENT: PROVIDE NEW, UL USTED, COMMERCIAL GRADE MATERIALS, DEVICES, EQUIPMENT, AND FIXTURES, SUITABLE FOR ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPUANT WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION, AND APPROVED BY THE ENGINEER. 0.17 SHOP DRAWINGS: BEFORE ORDERING EQUIPMENT AND MATERIALS, SUBMIT NOT LESS THAN FIVE CERTIFIED COPIES OF ALL SHOP AND EQUIPMENT DRAWINGS FOR ENGINEER'S REVIEW, WHO WILL RETAIN TWO COPIES. ONLY FURNISH SYSTEMS AND EQUIPMENT IN COMPLIANCE WITH ACCEPTED SHOP DRAWINGS. 0.18 INSTALLATION: INSTALL ALL MATERIALS, EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURERS' INSTRUCTIONS. 0.19 LAYOUT: INSTALL ALL PIPING AND DUCTWORK TO PRESENT A NEAT AND ORDERLY APPEARANCE. RUN ALL LINES PARALLEL WITH BUILDING CONSTRUCTION. MAINTAIN HEADROOM AND EQUIPMENT CLEARANCE, AND GRADIENT WHERE REQUIRED. ALLOW FOR EXPANSION AND CONTRACTION. 0.20 ACCESS DOORS: PROVIDE ACCESS DOORS OR PANELS FOR ALL VALVES, CLEANOUTS, DAMPERS, CONTROLS, DEVICES, AND OTHER ITEMS REQUIRING INSPECTION OR MAINTENANCE. ACCESS PANELS SERVING HVAC COMPONENTS SHALL BE 12- INCHES BY 12- INCHES MINIMUM OR LARGER TO PROVIDE SUFFICIENT WORKING CLEARANCE FOR COMPONENT BEING ACCESSED. 0.21 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT AND SUBMIT REPORT TO ENGINEER. 0.22 0 & M MANUALS: AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER OR OPERATOR. THE MANUAL SHALL INCLUDE BASIC DATA RELATING TO THE OPERATION AND MAINTENANCE OF HVAC SYSTEMS AND EQUIPMENT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. WHERE APPLICABLE, HVAC CONTROLS INFORMATION SUCH AS DIAGRAMS, SCHEMATICS, CONTROL SEQUENCE DESCRIPTIONS, AND MAINTENANCE AND CALIBRATION INFORMATION SHALL BE INCLUDED. 0.23 WARRANTY: UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF FINAL ACCEPTANCE. DURING WARRANTY PERIOD, REPAIR OR REPLACE DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP WITHOUT COST TO TENANT. 0.24 EQUIPMENT IDENTIFICATION: IDENTIFY ALL APPLICABLE ROOFTOP EQUIPMENT WITH TENANT'S NAME AND SPACE NUMBER, USING 2" PAINTED CHARACTERS OR STAMPED METAL TAG. 0.25 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT, PIPE AND DUCT LOCATIONS TO AVOID CONFLICTS WITH OTHER CONSTRUCTION AND TRADES. 0.26 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE THESE SPECIFICATIONS. 0.27 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS AND REQUIREMENTS. 0.28 PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS INCLUDED IN THESE SPECIFICATIONS MAY BE REQUIRED FOR THIS PROJECT. 0.29 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ERRORS, DISCREPANCIES OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAING SUCH NOTICE, BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 0.30 AS -BUILT DRAWINGS: SUBMIT AS -BUILT DRAWINGS TO TENANT PRIOR TO FINAL APPUCATION FOR PAYMENT. 15200 - THERMAL AND ACOUSTIC INSULATION 2.10 VIBRATION ISOLATION: PROVIDE EFFECTIVE VIBRATION ISOLATION DEVICES, AND FLEXIBLE CONNECTIONS, FOR ALL MOVING MACHINERY. PROVIDE DEVICES IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE ASHRAE HANDBOOK, HVAC APPLICATIONS (LATEST EDITION), CHAPTER "SOUND AND VIBRATION CONTROL ". 2.20 NOISE TRANSMISSION: INSTALL PIPING AND DUCTWORK FREE FROM CONTACT WITH STRUCTURE OR EQUIPMENT TO PREVENT NOISE TRANSMISSION. 2.30 INSULATION REQUIREMENTS: INSULATE SYSTEMS AS SPECIFIED ONLY AFTER THEY HAVE BEEN TESTED AND INSPECTED. CLEAN ALL SURFACES THOROUGHLY OF MOISTURE, FOREIGN MATERIAL, GREASE, AND RUST. INSTALL INSULATION CONTINUOUS THROUGH PENETRATIONS. 2.31 INSULATION HAZARDS: USE ONLY INSULATION ADHESIVES, SEALERS, AND COATINGS WITH FIRE HAZARD RATING NOT TO EXCEED 25/50/50 FLAME SPREAD, FUEL CONTRIBUTED, AND SMOKE DEVELOPED, IN ACCORDANCE WITH UL 723 AND ASTM E84. 2.34 ACOUSTICALLY UNED SUPPLY DUCT: UNLESS OTHERWISE INDICATED ON THE PLANS, UNE SUPPLY DUCTWORK WITHIN 10 -FEET OF THE DISCHARGE AND INTAKE OF AIR HANDUNG UNITS WITH 1" (MIN. R -4.2) THICK GLASS FIBER ACOUSTICAL DUCT UNER BOARD, OWENS- CORNING, OR EQUAL INCREASE DUCT SIZE INDICATED ON PLANS 2" EACH DIMENSION TO ACCOMMODATE DUCT LINER. MATERIALS SHALL HAVE A MOLD -, HUMIDITY -, AND CORROSION - RESISTANT SURFACE THAT MEETS THE REQUIREMENTS OF UL 181. 2.35 EXTERNALLY INSULATED SUPPLY DUCT: INSULATE SHEET METAL DUCTWORK WITH 2 -INCH FIBERGLASS BLANKET DUCT WRAP WITH AN INTEGRAL VAPOR BARRIER FACING, OWENS - CORNING, OR EQUAL. THE INSULATION SHALL HAVE MINIMUM R = 3.0 HR- -SQ.FT. -DEG. F /BTU -IN. THERMAL RESISTANCE. DO NOT INSULATE PORTIONS OF DUCTWORK WHICH ARE INTERNALLY UNED. DO NOT INSULATE SUPPLY AIR DUCTWORK IN CONDITIONED SPACES UNLESS OTHERWISE INDICATED ON THE DRAWINGS (RETURN AIR PLENUMS ARE NOT TO BE CONSIDERED AS CONDITIONED SPACES). 2.36 INSULATED EXHAUST AIR DUCT: EXTERNALLY INSULATE WITH 2" THICK GLASS FIBER INSULATION WITH KRAFT FOIL VAPOR BARRIER, OWENS - CORNING, OR EQUAL 2.40 INSULATED FLEXIBLE DUCT: GENERAL ENVIRONMENTAL CORPORATION TYPE G30A OR EQUAL 5' -0" MAXIMUM LENGTH WITH A MINIMUM ELBOW RADIUS OF 1.5 X D AND A MINIMUM R = 6.0 HR SQ. FT.- DEG. F /BTU -IN. THERMAL RESISTANCE. USE ONLY FOR FINAL CONNECTIONS TO CEIUNG DIFFUSERS. DO NOT USE FOR VAV. BOX INLET CONNECTIONS. Pub sq/ 15300 - FIRE PROTECTION 3.10 WORK INCLUDED: PROVIDE ENGINEERED DESIGN UNLESS OTHERWISE REQUIRED BY THE LANDLORD OR THE AUTHORITY HAVING JURISDICTION. FURNISH, FABRICATE AND INSTALL ALL MATERIALS, AND SECURE ALL NECESSARY APPROVALS FOR A COMPLETE NEW FIRE PROTECTION SYSTEM THROUGHOUT THE ENTIRE SPACE. 3.15 INCLUDED ARE AUTOMATIC SPRINKLER SYSTEMS COMPLETE WITH PIPING, VALVES, HANGERS AND SUPPORTS, SPRINKLER HEADS, FLOW SWITCHES, SLEEVES, APPURTENANCES AND ACCESSORIES FOR A COMPLETE, OPERABLE AND APPROVED FIRE PROTECTION SY51 tM. 3.20 CODES AND STANDARDS: COMPLY WITH NFPA 13, OTHER APPLICABLE NFPA STANDARDS, ALL PERTINENT REQUIREMENTS OF FACTORY MUTUAL INSURANCE COMPANY, ALL LOCAL STATE CODES AND ORDINANCES, AND THE FIRE MARSHALL HAVING JURISDICTION. 3.30 SYSTEM DESIGN: UNLESS OTHERWISE REQUIRED BY LANDLORD OR AUTHORITY HAVING JURISDICTION, THE SPRINKLER SYSTEM SHALL BE DESIGNED BASED ON THE INSTALLATI OF A HYDRAULICALLY CALCULATED SYSTEM. 3.40 SHOP DRAWINGS: PRIOR TO ANY MATERIALS BEING DELIVERED TO JOBSITE, SUBMIT COMPLETE SPRINKLER SYSTEM SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO LANDLORD'S REPRESENTATIVE AND AUTHORITY HAVING JURISDICTION. DO NOT BEGIN INSTALLATION OF SYS I tM UNTIL APPROVALS FROM BOTH PARTIES HAVE BEEN OBTAINED. 3.60 SPRINKLER HEADS: SEE SPRINKLER LEGEND AND SPRINKLER NOTES ON SHEET M -3. DO NOT INSTALL, OR RE- INSTALL, ANY SPRINKLER HEADS COVERED UNDER THE CENTRAL SPRINKLER COMPANY VOLUNTARY REPLACEMENT PROGRAM FOR 0 -RING SPRINKLERS. 3.70 INSTALLATION: SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE APPROVED SHOP DRAWINGS, AND FLUSHED IN ACCORDANCE WITH NFPA STANDARDS. 3.80 TESTING: UPON COMPLETION OF INSTALLATION, TEST AND RE -TEST THE COMPLETE SYSTEM, MAKE ALL REQUIRED ADJUSTMENTS, AND SECURE APPROVAL OF LANDLORD AND AUTHORITY HAVING JURISDICTION. 15700 - AIR HANDUNG AND VENTILATION 7.71 VARIABLE AIR VOLUME PARALLEL FAN POWERED TERMINAL UNITS: TERMINALS SHALL BE CERTIFIED UNDER ARI STANDARD 880 -89 AND CARRY THE ARI SEAL THE UNIT SHALL BE TESTED AS A SINGLE UNIT INCLUDING MOTOR AND FAN ASSEMBLY, PRIMARY AIR DAMPER ASSEMBLY, WATER OR ELECTRIC HEATING COILS AND ACCESSORIES, AS SHIPPED. ALL ELECTRICAL COMPONENTS SHALL BE UL USTED AND INSTALLED IN ACCORDANCE WITH THE NEC. THE ENTIRE TERMINAL SHALL BE ETL OR UL USTED AS A COMPLETE ASSEMBLY. CASING SHALL BE MINIMUM 22 GAUGE GALVANIZED SI ttL, INTERNALLY UNED WITH 1/2 -INCH DUAL DENSITY GLASS FIBER INSULATION WHICH COMPLIES WITH UL 181 AND NFPA 90A. ALL EXPOSED INSULATION EDGES SHALL BE COATED WITH NFPA 90A APPROVED SEALANT. CASING SHALL HAVE BOTTOM ACCESS PANEL FAN SHALL BE CONSTRUCTED OF STEEL AND HAVE FORWARD CURVED DYNAMICALLY BALANCED WHEEL WITH DIRECT DRIVE MOTOR. MOTOR SHALL BE OF ENERGY EFFICIENT DESIGN, PERMANENT SPLIT CAPACITOR TYPE, WITH INTEGRAL THERMAL OVERLOAD PROTECTION AND PERMANENTLY LUBRICATED BEARINGS, AND BE SPECIFICALLY DESIGNED FOR USE WITH AN SCR SPEED CONTROLLER UNIT SHALL UTIUZE A MANUAL SCR FOR SPEED CONTROL WHICH SHALL INCORPORATE A MINIMUM VOLTAGE STOP. TERMINALS SHALL INCLUDE A GASKETED BACKDRAFT DAMPER AT THE FAN SECTION DISCHARGE. DAMPER SHALL BE HEAVY GAUGE STEEL WITH SHAFT ROTATING IN SELF - LUBRICATING BEARINGS. NYLON BEARINGS ARE NOT ACCEPTABLE. SHAFT SHALL BE CLEARLY MARKED ON THE END TO INDICATE DAMPER POSITION. REMOVABLE MARKINGS ARE NOT ACCEPTABLE. DAMPER SHALL HAVE MECHANICAL STOP TO PREVENT OVERSTROKING AND A SYNTHETIC SEAL TO MINIMIZE CLOSE -OFF LEAKAGE. ELECTRIC COILS SHALL BE UL US I tU, SUPPUED AND INSTALLED ON THE TERMINAL BY THE FACTORY. INTEGRAL CONTROL PANEL SHALL BE HOUSED IN A NEMA 1 ENCLOSURE WITH HINGED ACCESS DOOR. ELECTRIC COILS SHALL CONTAIN A PRIMARY AUTOMATIC RESET THERMAL CUTOUT, A SECONDARY REPLACEABLE HEAT UMTTER PER ELEMENT, DIFFERENTIAL PRESSURE AIRFLOW SWITCH AND UNE TERMINAL BLOCK. UNIT SHALL INCLUDE AN INTEGRAL DOOR INTERLOCK TYPE DISCONNECT SWITCH. INDMDUAL COMPONENTS SHALL BE UL USTED OR RECOGNIZED. COILS SHALL INCLUDE MANUAL RESET SECONDARY THERMAL CUTOUTS, UNE FUSING, MERCURY CONTACTORS MOUNTED AND WIRED WITHIN THE CONTROL ENCLOSURE. 15800 - DUCTWORK AND APPURTENANCES 8.10 SHEET METAL DUCTWORK: A. FABRICATE AND INSTALL AS RECOMMENDED IN LATEST EDITIONS OF SMACNA HVAC DUCT CONSTRUCTION STANDARDS - -METAL AND FLEXIBLE AND THE ASHRAE GUIDE AND DATA BOOK FOR SHEET METAL DUCTWORK SERVING SUPPLY, RETURN AND EXHAUST SYSTEMS OPERATING BETWEEN -2.0 IN. -W.G. AND +2.0 IN. -W.G. MAXIMUM PRESSURE. INSTALL WHERE INDICATED ON THE PLANS. DUCT SIZES SHOWN ON THE DRAWINGS ARE NOMINAL INSIDE CLEAR DIMENSIONS. WHERE INTERNAL INSULATION IS PROVIDED, DUCT SIZES MUST BE INCREASED APPROPRIATELY TO MAINTAIN THE INDICATED DIMENSIONS. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (5% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL REQUIRED DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. B. FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ANSI /ASTM A -527, LOCKFORMING QUALITY, WITH ANSI /ASTM A -525 G90 ZINC COATING; MILL PHOSPI-IATIZED FOR EXPOSED LOCATIONS. C. DUCT SEALANT: UNITED DUCT SEALER, OR EQUAL D. SUPPORT MATERIALS: EXCEPT AS OTHERWISE INDICATED, PROVIDE HOT - DIPPED GALVANIZED STEEL FASTENERS, ANCHORS, RODS STRAPS, TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. E. ANY SUPPLY DUCTWORK AND PLENUMS THAT ARE DESIGNED TO OPERATE AT STATIC PRESSURE FROM 0.25 INCHES TO 2 INCHES WATER COLUMN INCLUSIVE WHICH ARE LOCATED OUTSIDE OF THE CONDITIONED SPACE OR IN RETURN PLENUMS SHALL HAVE JOINTS SEALED IN ACCORDANCE WITH SEAL CLASS C AS DEFINED IN THE SMACNA HVAC DUCT LEAKAGE TEST MANUAL PRESSURE SENSITIVE TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT WHERE SUCH DUCTS ARE DESIGNED TO OPERATE AT STATIC PRESSURES OF 1 INCH WATER COLUMN OR GREATER. 8.20 DUCTWORK ACCESSORIES: A. BALANCING DAMPERS: AIR BALANCE, INC., LOUVERS & DAMPERS, INC., RUSKIN, OR EQUAL PROVIDE MANUAL, SINGLE OR MULTIBLADE DAMPERS, AS INDICATED AND AS CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS. B. DAMPERS SHALL HAVE RIGID 2 -IN. X 1/2 -IN. X 10 GAUGE CHANNEL FRAMES, BALL OR BRONZE SLEEVE BEARINGS, 1 /2 -IN. POUSHED STEEL AXLES, 16- GAUGE, REINFORCED, FELT -EDGED BLADES (NOT OVER 8 -IN. WIDE) AND STOP FRAMES AROUND THE ENTIRE PERIMETER. VOLUME DAMPERS IN DUCTS LARGER THAN 12 -IN. X 6 IN. SHALL BE THE OPPOSED BLADE TYPE. DAMPERS IN ROUND DUCTS AND DUCTS 12 -IN. X 6-IN. AND SMALLER SHALL BE BUTTERFLY TYPE. ROUND BUTTERFLY TYPE VOLUME DAMPERS SHALL BE 30 GAUGE, GALVANIZED STEEL THROUGH 12 -IN. DIAMETER; 28 GAUGE FOR ABOVE 12 -IN. C. ALL DAMPERS SHALL BE EQUIPPED WITH STANDARD QUADRANTS OF SUITABLE SIZE IN EQUIPMENT ROOMS /AREAS AND YOUNG #301A, OR EQUAL, RECESSED -TYPE IN FINISHED AREAS. PROVIDE QUADRANT LOCKING DEVICE FOR EACH DAMPER ON ONE END OF THE SHAFT AND AN END BEARING PLATE ON THE OTHER END FOR DAMPER LENGTHS OVER 12 -IN. PROVIDE EXTENDED QUADRANT LOCKS AND EXTENDED BEARING PLATES FOR EXTERNALLY INSULATED DUCTWORK. APPROVED MANUFACTURERS ARE VENTFABRICS AND YOUNG REGULATOR CO. D. DAMPERS SHALL BE COATED WITH RED ZINC CHROMATE PRIMER OVER A BOND COAT. E. VOLUME DAMPERS, SPUTTERS AND DEFLECTORS SHALL BE PROVIDED IN ALL DUCTS TO PERMIT ACCURATE BALANCING OF THE SYSTEM. THE DAMPERS, SPUTTERS AND DEFLECTORS SHALL BE ADJUSTED TO SATISFY THE HEATING AND VENTILATING REQUIREMENTS OF THE CONDITIONED SPACE AND LOCKED IN PLACE. 8.40 AIR OUTLETS AND INLETS: FURNISH AND INSTALL TITUS, KRUEGER, OR APPROVED EQUAL, AS SCHEDULED. OPPOSED BLADE VOLUME DAMPERS FOR REGISTERS SHALL BE TITUS SERIES AG -35, KRUEGER SERIES OBC, OR EQUAL, OPPOSED BLADE TYPES WITH VERTICAL BLADES AND SCREWDRIVER SLOTS OR ALLEN WRENCH ADJUSTMENT ACCESSIBLE THROUGH THE REGISTER. IT SHALL BE THE CONTRACTOR'S RESPONSIBILJTY TO PROVIDE MISCELLANEOUS ITEMS AS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPES OF WALLS AND CEIUNGS USED ON THE PROJECT. THIS SHALL INCLUDE SUCH ITEMS AS FASTENERS, PLASTER RINGS, SUPPORTS, ETC. 8.60 FLEXIBLE CONNECTIONS: VENTFABRICS, INC., DURO DYNE, OR EQUAL PROVIDE FLEXIBLE DUCT CONNECTIONS WHEREVER DUCTWORK CONNECTS TO VIBRATION ISOLATED EQUIPMENT AND WHERE SHOWN OR NOTED. MAKE AIR -TIGHT JOINTS. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR THERMAL, AXIAL, TRANSVERSE AND TORSIONAL MOVEMENT. 15900 - SYSTEM CONTROL AND OPERATION 9.10 SPACE TEMPERATURE CONTROL FURNISH AND INSTALL UNLESS NOTED OTHERWISE, ALL THERMOSTATS, SENSORS, CONTROLLERS, RELAYS, CONTACTORS, DAMPERS, ACTUATORS, TUBING, CONTROL WIRING AND ALL OTHER ITEMS AND MATERIALS NECESSARY FOR A COMPLETE AND PROPERLY OPERATING TEMPERATURE CONTROL SYSTEM AS SPECIFIED BELOW. ALL THERMOSTATS AND OTHER CONTROL COMPONENTS SHALL BE HONEYWELL, OR APPROVED EQUAL, UNLESS SPECIFIED OTHERWISE. ALL CONTROL WIRING SHALL BE BY MECHANICAL CONTRACTOR AND SHALL BE INSTALLED IN CONDUIT. 9.11 THERMOSTAT: REFER TO "HVAC CONTROLS ". 9.20 SEQUENCE OF CONTROLS: REFER TO "HVAC CONTROLS ". 15950 - TESTING, ADJUSTING, BALANCING 9.51 THIS CONTRACTOR SHALL EMPLOY AN INDEPENDENT NEBB, AABC, OR TABB CERTIFIED TESTING AND BALANCING CONTRACTOR. THIS INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS. THE PERSON OR AGENCY RESPONSIBLE FOR BALANCING OF THE SYSTEMS SHALL DOCUMENT IN WRITING THE AMOUNT OF OUTDOOR AIR BEING PROVIDED AND DISTRIBUTED FOR THE BUILDING OCCUPANTS AND ANY OTHER SPECIALTY VENTILATION. TWO COPIES OF A WRITTEN REPORT IN FORMAT USTED ABOVE SHALL BE SUBMITTED TO THE OWNER, TWO COPIES SHALL BE SUBMITTED TO THE LANDLORD PRIOR TO OCCUPANCY, AND TWO COPIES SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. 9.52 ENSURE ALL VAV BOXES ON THIS AIR HANDLER / ROOFTOP UNIT ARE ADJUSTED TO THEIR RESPECTIVE MAXIMUM SETPOINTS DURING BALANCING TO ENSURE PROPER AIRFLOW WHEN SYSTEM IS OPERATING AT MAXIMUM (PEAK) COOUNG CAPACITY. COORDINATE SETTING OF VAV BOXES IN OTHER TENANT SPACES IN FIELD WITH LANDLORD'S FIELD REPRESENTATIVE. 9.53 HVAC CONTROL SYSTEMS SHALL BE TESTED TO ASSURE THAT CONTROL ELEMENTS ARE CALIBRATED, ADJUSTED, AND IN PROPER WORKING CONDITION. • c C z m 0 0 W LAL 1■■1■IA1 RECEI F- CITY OF TUKWILA NAP 0 32008 RMIT CENTER SHEET NUMBER M 3 SHEET 14 OF 17 CEILING MOUNTED LIGHT FIXTURES SYMBOL DESCRIPTION MFR. STYLE/ CAT. NO. VOLTS/ LAMPS COMMENTS N/A N/A CIRCUITS 2'x2' Fluorescent Fixture w/ 9 Cell White Parabolic Lens Surface Mounted Single Circuit Track System (Silver) Incandescent Gimbal Ring Open Back MonopointTrack Head (Silver) 4" Recessed Incandescent Downlight 8" Recessed Incandescent Downlight Exit Ught Fixture with 90 Minute Battery Backup Recessed Emergency Light with 90 Minute Battery Backup Combination Fan/ Light 100 CFM 9" Recessed Compact Fluor. Downlight 4' Fluorescent Strip Fixture Surface Mounted Emergency Ught with 90 Minute Battery Backup Designates Night -light UGHTOUER JUNO JUNO JUNO JUNO ATUTE DUAL -UTE NUTONE JUNO SIMKAR ATUTE PLA2G9WP 3FT277X3 T2NA, T4NA, T6NA, T8NA V689NA TC44/ 447CWH MC8P3870/ 8838CWH PNLRU EZ -2R 8663P CH9 226/ 32/42T- 950CWH CH -232 PCI -10 3 PLL40/35K 77 Volts 3) U- 40W 120 Volts 120 Volts 75W PAR 30 NFL 120 Volts 50W MR16 FL EXN 120 Volts 70W PAR38 MH FL 277 Volts (2) 15T6 12W 277 Volts 8W 120 Volts 1 -100W 120 Volts (2) 42W 35K 277 Volts 2 -F32T8 TL735 120/277 V 8W Sales Area See Note 1 Below Sales Area (Storefront Soffit) Sales Area Sales Area, Stockroom Egress Corridor Sales Area Toilet Room Storefront Soffit Stockroom Egress Corridor Stockroom, Toilet Room Egress Corridor ./g Light 20 •, �ci 0 D O D, 0 ® E EM F ■ r■ 0 PL SF 120 �� Y A 20 HA -3 LA -5 NOTE 1: ALL FLUORESCENT LAMPS SHALL BE CHROMA 30 (UNLESS OTHERWISE NOTED). NOTE 2: T.G.C. TO FIELD VERIFY EXACT LOCATION & POSITIONING OF TRACK HEADS WITH TENANT'S PROJECT MANAGER PRIOR TO INSTALLATION. NOTE 3: NEON LIGHTING IS TO BE 13mm DOMESTIC GLASS CUSTOM FIT. FABRICATOR TO PROVIDE SHOP DRAWINGS OF THE PROPOSED NEON LIGHTING, SHOWING UGHT FIXTURES, MOUNTING AND TRANSFORMERS FOR APPROVAL LOCATE TRANSFORMERS ABOVE CEILING IN AN ACCESSIBLE LOCATION. NEON COLORS TO BE AS DESIGNATED ON CEIUNG PLAN. ALL HOUSINGS TO BE RECESSED BEHIND SOFFIT WALL OR ABOVE CEIUNG. SEE DETAILS FOR MOUNTING LOCATION OF NEON. NOTE; SEE ARCHITECTURAL REFLECTED CEIUNG PLAN FOR EXACT QUANTITY AND LOCATION OF UGHT FIXTURES. IF DISCREPANCIES EXIST BETWEEN THIS SHEET AND ARCHITECTURAL REFLECTED CEILING PLAN, ARCHITECTURAL REFLECTED CEIUNG PLAN WILL TAKE PRECEDENCE. CONTACTOR SCHEDULE MARK LOAD CONTROL COIL V LINE V POLES AMP CIRCUITS C1 STOREFRONT SIGN & UGHTS TS1 120 120 8 20 LA- 1,3,10,12 C2 SALES LTG MC1 120 120/277 4 20 HA -3 LA -5 C3 SALES LTG MC2 120 120/277 4 20 HA - 5 LA 1 VERIFY ALL EXISTING CONDITIONS IN THE FIELD. , NOTE; THE ELECTRICAL CONTRACTOR SHALL PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF CIRCUITING INDICATED. NOTE: THE LOCAL BUILDING DEPARTMENT REQUIRES A MINIMUM OF ONE FOOT CANDLE OF EMERGENCY UGHTING THROUGHOUT THE ENTIRE TENANT SPACE. QE _QLITION; THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, UGHT FIXTURES, DEVICES, CONDUIT AND WIRE, ETC.. NOT BEING REUSED. ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH THE LANDLORD'S MECHANICAL /ELECTRICAL CRITERIA. ALL CONTRACTORS SHALL OBTAIN A COPY OF THE CRITERIA FROM THE LANDLORD'S TENANT COORDINATOR, OR MALL OPERATIONS MANAGER AND BECOME FAMILIAR WITH THE REQUIREMENTS CONTAINED WITHIN PRIOR TO BIDDING THE JOB. WHERE LANDLORD'S REQUIREMENTS CONFLICT WITH CODES OR ORDINANCES THE STRICTEST INTERPRETATION SHALL APPLY. HA -9 SF HA -9 SF HA -9 HA -9 E HAA- -9 S F -- HA-9 SF HA -9 LA -11 1=1 F LA -11 HA{-9 Y � HA -9 YH HA -9 EXIT AND EMERGENCY UGHTING SHALL BE PER REQUIREMENTS OF LOCAL GOVERNING CODES. BATTERY PACKS FOR EXIT AND EMERGENCY UGHTS MUST BE REMOTE OR RECESSED. PAINT EXPOSED SURFACES TO MATCH ADJACENT FINISH. E HA -1 II A HA -5 m EM HA -1 A HA -3 A HA -5 E M ® HA -1 HA -3 r T N/L A HA -5 HA A - 3 A HA -1 A HA -3 NOTE: ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANT'S VENDOR. NOTE: FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. C.3 L A HA-3 A HA -5 A HA -3 A HA -5 N/L • A HA -5 A HA -1 A HA -5 A HA -3 EM ®HA-1 EM WHA -1 A HA -5 A HA -3 A HA -5 A HA -3 II 1 ® EM HA -1 N/L A HA -5 A HA -3 A HA -1 A HA -3 0 1 2 4 LA -34 NEUTRAL HOT SEE CONTACTOR SCHEDULE FOR ADDITIONAL INFORMATION. TIME SWITCH (TS1) w- 1 -34 { 1 { { CONTACTOR CONTROL DETAIL NOT TO SCALE MC1 MC2 C1 C3 C2j- -- STOREFRONT UGHTS SIGN & SHOW. WINDOW REC. SALES AREA UGHTS SALES AREA LIGHTS LIGHTING PLAN A HA-5 A HA -3 A HA -3 8 FEET 1 EM � HA -1 EM HA -1 A HA -5 A HA -3 A A HA -5 HA -5 HA3 N/L ® EM HA-1 A\ HA -1 1 /4 = 1 - 0 " A 3 1) // 5' g 81 D1 LA -5 0 D1 LA -9 0 D1 LA -5 D1 0 LA--9 D1 0 LA -5 LIGHTING PLAN KEY NOTES 1. LOCATION OF ELECTRICAL SERVICE EQUIPMENT. SEE POWER RISER DIAGRAM AND PANELBOARD SCHEDULES ON SHEET E -3. MAINTAIN REQUIRED CODE CLEARANCES OF ALL ELECTRICAL EQUIPMENT. 2. CIRCUIT EXHAUST FAN /LIGHT COMBINATION AS INDICATED. FAN AND LIGHT SHALL BE CONTROLLED BY THE SAME SWITCH. 3. INSTALL WATT STOPPER #WS -120 -W OCCUPANCY SENSOR. SENSOR SHALL BE FURNISHED BY UGHTING VENDOR. MAKE FINAL CONNECTIONS. 4. INSTALL WATT STOPPER #C1 -200 CEIUNG MOUNTED OCCUPANCY SENSOR. SENSOR SHALL BE FURNISHED BY UGHTING VENDOR. MAKE ANAL CONNECTIONS. 5. INSTALL WATT STOPPER POWER PACK. POWER PACK SHALL BE FURNISHED BY UGHTING VENDOR. MOUNT ON WALL ABOVE CEIUNG IN AN ACCESSIBLE LOCATION. PROVIDE ALL NECESSARY ITEMS FOR A FULLY FUNCTIONING SYSTEM. 6. PROVIDE TIMESWITCH: PARAGON MODEL 7000 SERIES OR EQUAL WITH 7 - 24 HOUR SCHEDULE FORMAT, MIN. (4) N.O. 20 AMP 120/277 VOLT CONTACTS 120 VOLT COIL AND SPRING WOUND RIDE THROUGH SWITCH TO CONTROL STORE FRONT SIGN AND UGHTING OR CONTACTORS AS INDICATED. 7. PROVIDE UGHTING CONTACTOR(S): ASCO 917 SERIES OR EQUAL WITH 120 VOLT COIL, MINIMUM 20 AMP 120/277 VOLT CONTACTS ELECTRICALLY OPERATED AND MECHANICALLY HELD, 3 -WIRE CONTROL SEE CONTACTOR SCHEDULE FOR ADDITIONAL INFORMATION. CONTACTOR(S) CONTROLLED VIA TIMESWITCH AND /OR MOMENTARY CONTACT SWITCH AS INDICATED. SEE CONTACTOR CONTROL DETAIL 2/E - 8. EMERGENCY UGHTING AND EXIT SIGN SHALL BE WIRED AHEAD OF SWITCHING DEVICE 9. CENTER TYPE "D1" LIGHT FIXTURES BETWEEN GLAZING CHANNEL AND GYPSUM BOARD SOFFIT. 10. EXIT SIGN TO BE MOUNTED, CENTERED ABOVE DOOR AT 7' -6" AFF TO CENTERLINE OF FIXTURE. 11. EXIT SIGN TO BE MOUNTED ON FACE OF SOFFIT SO AS NOT TO BE VISIBLE FROM MALL COMMON AREA 12. MASTER SWITCH LOCATION: PROVIDE (2) MASTER SWITCHES FOR CONTROL OF CONTACTORS. SEE CONTACTOR SHEDULE ON THIS SHEET. MOUNT ON WALL BEHIND CASHWRAP. VERIFY EXACT LOCATION WITH ARCHITECT. J -BOX: FOR NEON UGHTING ON CIRCUIT LA -3, VIA TS1. MOUNT NEON TRANSFORMER AS REQUIRED. O D1 LA -5 0 D1 LA -9 0 D1 LA -5 EM ® �+ D1 HA = 3 O LA -9 EM HA -1 ® 0 D1 0 LA--9 0 D1 LA -5 D1 LA -5 D1 LA -9 0 01 LA -5 1 D1 LA -9 J -BOX FOR NEON UGHTING ON CIRCUIT LA -3, VIA TS1. MOUNT NEON TRANSFORMER AS REQUIRED. E HA -1 11 0 II 0 a 1 PL LA -1 PL LA -1 LA D -1 9 LA D -1 9 LA D -1 9 VOLTARC SPARKLING BLUE NEON ACCENT STRIP W /NATURAL ALUMINUM PANEL ON FACE OF SOFFIT, FURNISHED AND INSTALLED BY TENANT'S SIGN CONTRACTOR. SEE DETAIL 2/A1.1 FOR ADDITIONAL INFORMATION. VOLTARC SPARKING BLUE NEON ACCENT STRIP W /NATURAL ALUMINUM PANEL ON FACE OF SOFFIT, FURNISHED AND INSTALLED BY TENANT'S SIGN CONTRACTOR. SEE DETAIL 2/A1.1 FOR ADDITIONAL INFORMATION. r ^ i tap 0 z m 0 H U U CO J Ian iticaz A RECE :'ti E CITY OF TUK1rdILA MA 0 3 7008 PERMIT CENTER SHEET NUMBER E -1 SHEET 15 OF 17 EQUIPMENT SCHEDULE NO. NAME VOLT/ PHASE LOAD CONDUIT/ WIRE CONTROL STARTER PNL CCT. NO. DISC. SWITCH FUSE SIZE NOTES HP KW VAV -1 VAV BOX #1 277/480/3 1/3 5.0 3/4 "C. -4#12 CU. DNA 5 DIV.15 HA 8,10,12 30A /3P 15 SEE KEYNOTE VAV -2 VAV BOX #2 277/480/3 1/3 5.0 3/4 "C. -412 CU. DIV.15 DIV.15 HA 14,16,18 30A /3P 15 SEE KEYNOTE WH -1 WATER HEATER #1 120/1 -- 1.7 3/4 "C -2#12 - CU DN. 15 -- LA 13 -- - SEE KEYNOTE TYPE "F" FAN/UGHT COMBO. 120/1 -- 0.2 3/4 "C -2 #12 - CU WALL SW. -- LA 11 -- - SEE KEYNOTE ON SHEET El I ® 0 ei P- 7 0 T 1' -6" PL MEMEMNINO • INSTALL AT P.O.S. CABINET. C LA -15 NOTE ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANT'S VENDOR. 18 "6 LA -30 FOLDING TABLE NQTE; TENANT EC. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEILING FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. NOTE: FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. a® LA46 9 VAV -2 -be* LA -32 0 f LA 49 y 0 POWER PLAN KEY NOTES 1. PROVIDE TELEPHONE BACKBOARD AS SPECIFIED. 2. PROVIDE TELEPHONE OUTLET, CONDUIT AND CABLE. SEE DETAIL 3/E -3. 3. LOCATION OF ELECTRICAL SERVICE EQUIPMENT. SEE POWER RISER DIAGRAM AND PANELBOARD SCHEDULES ON SHEET E-3. MAINTAIN REQUIRED CODE CLEARANCES OF ALL ELECTRICAL EQUIPMENT. 4. NOT USED. 5. ALL CONDUIT AND WIRING AT CASHWRAP SHALL BE CONCEALED IN CASEWORK. COORDINATE WITH CASEWORK MANUFACTURER. 6. PROVIDE J -BOX WITH DISCONNECT SWITCH IN ACCESSIBLE CONCEALED SPACE FOR STOREFRONT SIGN. FIELD VERIFY EXACT LOCATION. SEE SPECIFICATION ON SHEET E -3 FOR ADDITIONAL INFORMATION. 7. PROVIDE FLUSH DUPLEX RECEPTACLE IN SHOW WINDOW CEIUNG. COLOR SHALL MATCH ADJACENT SURFACE. 8. ISOLATED GROUND CIRCUITS SHALL BE INSTALLED IN SEPARATE CONDUIT FROM NORMAL POWER CIRCUITS. EACH IG CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AND INSULATED GROUND WIRE. THE GROUND WIRE SHALL BE CONTINUOUS BACK TO THE PANEL AND CONNECTED TO THE GROUND BUS WITHIN THE PANEL IG RECEPTACLES SHALL BE HUBBELL NO. IG -5362, OR APPROVED EQUAL 9. CORE BORE FLOOR SLAB AND INSTALL CONDUIT WITH PULLWIRE. PROVIDE BUSHING AT EACH END. PATCH AND REPAIR FLOOR TO MATCH EXISTING CONDITION. COORDINATE WORK WITH MALL OPERATIONS MANAGER. 10. SEE EQUIPMENT SCHEDULE FOR MECHANICAL EQUIPMENT INFORMATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. 11. PROVIDE A 1 1/2" CONDUIT FOR DATA ONES FROM CASHWRAP. COORDINATE WITH TENANT'S PROJECT MANAGER. 12. PROVIDE DEVICES SHOWN IN BACKROOM. COORDINATE WITH TENANT'S PROJECT MANAGER. 13. PROVIDE A DUPLEX RECEPTACLE AND LOW VOLTAGE JUNCTION WITH 1"C. WITH PULL STRING, STUB UP ABOVE CEIUING IN ACCESSIBLE LOCATION. VERIFY EXACT MOUNTING LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. 14. NOT USED. 15. PROVIDE 120 VOLT CONNECTION TO SENSORMATIC SYSTEM. COORDINATE EXACT REQUIREMENTS WITH TENANT'S PROJECT MANAGER. 16. NOT USED. 17. NOT USED. 18. PROVIDE DEVICE IN CEILING FOR LOSS PREVENTION REQUIREMENT. COORDINATE WITH TENANT'S PROJECT MANAGER. 19. ALL CONDUITS ROUTED TO FLOOR FIXTURES SHALL BE STUBBED UP AT 0' -4" AFF. INSTALL BUSHING AT TOP AND PROVIDE PULL STRING.. 20. TENANT'S A/V VENDOR SHALL FURNISH AND INSTALL CEIUNG MOUNTED SPEAKERS AND RELATED WIRING AS INDICATED ON PLAN. COORDINATE WITH TENANT'S PROJECT MANAGER. 21. PROVIDE SERVICE DOOR BUZZER SYSTEM: EDWARDS: 340- 4G5 -24VAC BUZZER, ONE (1) NEW ANNUNCIATOR LOCATED AT THE CASHWRAP AND ONE (1) BUZZER IN THE OFFICE, 852 WEATHERPROOF PUSHBUTTON, 592 TRANSFORMER. BUZZER SYSTEM WIRE NEED NOT BE INSTALLED IN CONDUIT UNLESS REQUIRED BY LANDLORD OR LOCAL AUTHORITY. 22. RECEPTACLES IN THE SALES AREA SHALL BE LOCATED 12' -O" ON CENTER. FIELD VERIFY EXACT LOCATION. 23. NOT USED. 24. PROVIDE FLUSH MOUNTED J- BOX AT 18" AFF AT LVS STATION IN BACKROOM. J -BOX SHALL HAVE (2) 1" CONDUITS STUBBED UP ABOVE CEIUNG TO ACCOMODATE LOW VOLTAGE WIRING FROM SALES AREA LVS STATION(S). COORDINATE WITH TENANT PROJECT MANAGER. 25. NOT USED. 26. NOT USED. 27. ELECTRICAL CONTRACTOR SHALL PROVIDE A 3/4" CONDUIT WITH PULLSTRING STUBBED UP ABOVE CEILING FOR LVS WIRING BY TENANT. CONDUIT SHALL BE CUT FLUSH TO FACE OF WALL AT 18" A.F.F., AND NIPPLE SHALL BE INSTALLED 28. PROVIDE RECEPTACLE AND UGHT SWITCH AT VAV BOX UNITS. PROVIDE PORCELAIN SOCKET WITH (1) 60WA19 LAMP, MOUNT NEAR ACCESS PANEL. VERIFY EXACT LOCATION WRH MECHANICAL CONTRACTOR. LA.8 POWER PLAN H H 1 1 E A I INIMMIMINIIII•11111•111•1111111IMEIMINIIIIMMIRIIIIMIEM11, � ! ►I 0 1 2 4 8 FEET LAV NOTE ALL CONDUITS AND CABLE PROVIDED BY ELECTRICAL CONTRACTOR. ALL CONDUITS TO RUN WITHIN FIXTURE FROM DEMISING WALL ADJACENT TO CASHWRAP. SLAB CORE BORING NOT REQUIRED. NOTE: SEE FLOOR PLAN FOR CORRECT ORIENTATION. NOTE: VERIFY CASH WRAP ELECTRICAL REQUIR ENTS WITH TENANT PROJECT MANAGER. UNES #1 AND 1 2 FOR TELEPHONE UNES 2 UNE RJ -141 TELEPHONE JACK. LA -6 LA -2 Q " - i 0 D // DEDICATED DUPLEX OUTLET IN AN ACCESSIBLE LOCATION FOR FUTURE LOSS PREVENTION. LA -6 LA- RJ -45 TELEPHONE JACK FOR DATA UNES 1 1/2" CONDUIT WITH PULLSTRING FROM POS CABINET WITHIN STOCKROOM FOR DATA UNE. TENANT'S VENDOR TO PULL DATA CABLE. 3/4" CONDUIT WITH PULLSTRING FOR TELEPHONE SYS i 1. EXTEND TO TELEPHONE BACKBORAD IN STOCKROOM. LA -8 ,}o LA -8 ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX IN CASH WRAP FOR ALTRONIX ALTV248 CAMERA POWER SUPPLY UNIT. COORDINATE NUMBER AND LOCATION OF CAMERAS WITH TENANT'S PROJECT MANAGER T ( 7\ CASH WRAP POWER PLAN 7 A 8 FEET 1/4" = 1' -0" Il il 1♦ Is -■r-� I 171 LA 1/4" = 1' -0" L i (1) 1 1/2" CONDUIT WITH PULLSTRING FOR A/V EQUIPMENT. RUN WITHIN MILLWORK AND STUB ABOVE CEIUNG TO AN ACCESSIBLE LOCATION. BUSH TOP END. (2) 3/4" CONDUIT AT CASHWRAP AND PANELBOARD: (1) CONDUIT FOR IG RECEPTACLES CLEAN POWER AND (1) CONDUIT FOR RECEPTACLES DIRTY POWER. RUN CONDUIT WITHIN MILLWORK OF CASHWRAP. RECE;' .'r `' CITY OF TUKWILA MAP 0 3 2008 PERMIT CENTER 9 „ Z Q O ab N O a 1 IA WI ea ea I SHEET NUMBER E -2 SHEET 16 OF 17 0 a \ - PL MEMEMNINO • INSTALL AT P.O.S. CABINET. C LA -15 NOTE ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANT'S VENDOR. 18 "6 LA -30 FOLDING TABLE NQTE; TENANT EC. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEILING FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. NOTE: FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. a® LA46 9 VAV -2 -be* LA -32 0 f LA 49 y 0 POWER PLAN KEY NOTES 1. PROVIDE TELEPHONE BACKBOARD AS SPECIFIED. 2. PROVIDE TELEPHONE OUTLET, CONDUIT AND CABLE. SEE DETAIL 3/E -3. 3. LOCATION OF ELECTRICAL SERVICE EQUIPMENT. SEE POWER RISER DIAGRAM AND PANELBOARD SCHEDULES ON SHEET E-3. MAINTAIN REQUIRED CODE CLEARANCES OF ALL ELECTRICAL EQUIPMENT. 4. NOT USED. 5. ALL CONDUIT AND WIRING AT CASHWRAP SHALL BE CONCEALED IN CASEWORK. COORDINATE WITH CASEWORK MANUFACTURER. 6. PROVIDE J -BOX WITH DISCONNECT SWITCH IN ACCESSIBLE CONCEALED SPACE FOR STOREFRONT SIGN. FIELD VERIFY EXACT LOCATION. SEE SPECIFICATION ON SHEET E -3 FOR ADDITIONAL INFORMATION. 7. PROVIDE FLUSH DUPLEX RECEPTACLE IN SHOW WINDOW CEIUNG. COLOR SHALL MATCH ADJACENT SURFACE. 8. ISOLATED GROUND CIRCUITS SHALL BE INSTALLED IN SEPARATE CONDUIT FROM NORMAL POWER CIRCUITS. EACH IG CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AND INSULATED GROUND WIRE. THE GROUND WIRE SHALL BE CONTINUOUS BACK TO THE PANEL AND CONNECTED TO THE GROUND BUS WITHIN THE PANEL IG RECEPTACLES SHALL BE HUBBELL NO. IG -5362, OR APPROVED EQUAL 9. CORE BORE FLOOR SLAB AND INSTALL CONDUIT WITH PULLWIRE. PROVIDE BUSHING AT EACH END. PATCH AND REPAIR FLOOR TO MATCH EXISTING CONDITION. COORDINATE WORK WITH MALL OPERATIONS MANAGER. 10. SEE EQUIPMENT SCHEDULE FOR MECHANICAL EQUIPMENT INFORMATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. 11. PROVIDE A 1 1/2" CONDUIT FOR DATA ONES FROM CASHWRAP. COORDINATE WITH TENANT'S PROJECT MANAGER. 12. PROVIDE DEVICES SHOWN IN BACKROOM. COORDINATE WITH TENANT'S PROJECT MANAGER. 13. PROVIDE A DUPLEX RECEPTACLE AND LOW VOLTAGE JUNCTION WITH 1"C. WITH PULL STRING, STUB UP ABOVE CEIUING IN ACCESSIBLE LOCATION. VERIFY EXACT MOUNTING LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. 14. NOT USED. 15. PROVIDE 120 VOLT CONNECTION TO SENSORMATIC SYSTEM. COORDINATE EXACT REQUIREMENTS WITH TENANT'S PROJECT MANAGER. 16. NOT USED. 17. NOT USED. 18. PROVIDE DEVICE IN CEILING FOR LOSS PREVENTION REQUIREMENT. COORDINATE WITH TENANT'S PROJECT MANAGER. 19. ALL CONDUITS ROUTED TO FLOOR FIXTURES SHALL BE STUBBED UP AT 0' -4" AFF. INSTALL BUSHING AT TOP AND PROVIDE PULL STRING.. 20. TENANT'S A/V VENDOR SHALL FURNISH AND INSTALL CEIUNG MOUNTED SPEAKERS AND RELATED WIRING AS INDICATED ON PLAN. COORDINATE WITH TENANT'S PROJECT MANAGER. 21. PROVIDE SERVICE DOOR BUZZER SYSTEM: EDWARDS: 340- 4G5 -24VAC BUZZER, ONE (1) NEW ANNUNCIATOR LOCATED AT THE CASHWRAP AND ONE (1) BUZZER IN THE OFFICE, 852 WEATHERPROOF PUSHBUTTON, 592 TRANSFORMER. BUZZER SYSTEM WIRE NEED NOT BE INSTALLED IN CONDUIT UNLESS REQUIRED BY LANDLORD OR LOCAL AUTHORITY. 22. RECEPTACLES IN THE SALES AREA SHALL BE LOCATED 12' -O" ON CENTER. FIELD VERIFY EXACT LOCATION. 23. NOT USED. 24. PROVIDE FLUSH MOUNTED J- BOX AT 18" AFF AT LVS STATION IN BACKROOM. J -BOX SHALL HAVE (2) 1" CONDUITS STUBBED UP ABOVE CEIUNG TO ACCOMODATE LOW VOLTAGE WIRING FROM SALES AREA LVS STATION(S). COORDINATE WITH TENANT PROJECT MANAGER. 25. NOT USED. 26. NOT USED. 27. ELECTRICAL CONTRACTOR SHALL PROVIDE A 3/4" CONDUIT WITH PULLSTRING STUBBED UP ABOVE CEILING FOR LVS WIRING BY TENANT. CONDUIT SHALL BE CUT FLUSH TO FACE OF WALL AT 18" A.F.F., AND NIPPLE SHALL BE INSTALLED 28. PROVIDE RECEPTACLE AND UGHT SWITCH AT VAV BOX UNITS. PROVIDE PORCELAIN SOCKET WITH (1) 60WA19 LAMP, MOUNT NEAR ACCESS PANEL. VERIFY EXACT LOCATION WRH MECHANICAL CONTRACTOR. LA.8 POWER PLAN H H 1 1 E A I INIMMIMINIIII•11111•111•1111111IMEIMINIIIIMMIRIIIIMIEM11, � ! ►I 0 1 2 4 8 FEET LAV NOTE ALL CONDUITS AND CABLE PROVIDED BY ELECTRICAL CONTRACTOR. ALL CONDUITS TO RUN WITHIN FIXTURE FROM DEMISING WALL ADJACENT TO CASHWRAP. SLAB CORE BORING NOT REQUIRED. NOTE: SEE FLOOR PLAN FOR CORRECT ORIENTATION. NOTE: VERIFY CASH WRAP ELECTRICAL REQUIR ENTS WITH TENANT PROJECT MANAGER. UNES #1 AND 1 2 FOR TELEPHONE UNES 2 UNE RJ -141 TELEPHONE JACK. LA -6 LA -2 Q " - i 0 D // DEDICATED DUPLEX OUTLET IN AN ACCESSIBLE LOCATION FOR FUTURE LOSS PREVENTION. LA -6 LA- RJ -45 TELEPHONE JACK FOR DATA UNES 1 1/2" CONDUIT WITH PULLSTRING FROM POS CABINET WITHIN STOCKROOM FOR DATA UNE. TENANT'S VENDOR TO PULL DATA CABLE. 3/4" CONDUIT WITH PULLSTRING FOR TELEPHONE SYS i 1. EXTEND TO TELEPHONE BACKBORAD IN STOCKROOM. LA -8 ,}o LA -8 ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX IN CASH WRAP FOR ALTRONIX ALTV248 CAMERA POWER SUPPLY UNIT. COORDINATE NUMBER AND LOCATION OF CAMERAS WITH TENANT'S PROJECT MANAGER T ( 7\ CASH WRAP POWER PLAN 7 A 8 FEET 1/4" = 1' -0" Il il 1♦ Is -■r-� I 171 LA 1/4" = 1' -0" L i (1) 1 1/2" CONDUIT WITH PULLSTRING FOR A/V EQUIPMENT. RUN WITHIN MILLWORK AND STUB ABOVE CEIUNG TO AN ACCESSIBLE LOCATION. BUSH TOP END. (2) 3/4" CONDUIT AT CASHWRAP AND PANELBOARD: (1) CONDUIT FOR IG RECEPTACLES CLEAN POWER AND (1) CONDUIT FOR RECEPTACLES DIRTY POWER. RUN CONDUIT WITHIN MILLWORK OF CASHWRAP. RECE;' .'r `' CITY OF TUKWILA MAP 0 3 2008 PERMIT CENTER 9 „ Z Q O ab N O a 1 IA WI ea ea I SHEET NUMBER E -2 SHEET 16 OF 17 • INSTALL AT P.O.S. CABINET. C LA -15 NOTE ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANT'S VENDOR. 18 "6 LA -30 FOLDING TABLE NQTE; TENANT EC. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEILING FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. NOTE: FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. a® LA46 9 VAV -2 -be* LA -32 0 f LA 49 y 0 POWER PLAN KEY NOTES 1. PROVIDE TELEPHONE BACKBOARD AS SPECIFIED. 2. PROVIDE TELEPHONE OUTLET, CONDUIT AND CABLE. SEE DETAIL 3/E -3. 3. LOCATION OF ELECTRICAL SERVICE EQUIPMENT. SEE POWER RISER DIAGRAM AND PANELBOARD SCHEDULES ON SHEET E-3. MAINTAIN REQUIRED CODE CLEARANCES OF ALL ELECTRICAL EQUIPMENT. 4. NOT USED. 5. ALL CONDUIT AND WIRING AT CASHWRAP SHALL BE CONCEALED IN CASEWORK. COORDINATE WITH CASEWORK MANUFACTURER. 6. PROVIDE J -BOX WITH DISCONNECT SWITCH IN ACCESSIBLE CONCEALED SPACE FOR STOREFRONT SIGN. FIELD VERIFY EXACT LOCATION. SEE SPECIFICATION ON SHEET E -3 FOR ADDITIONAL INFORMATION. 7. PROVIDE FLUSH DUPLEX RECEPTACLE IN SHOW WINDOW CEIUNG. COLOR SHALL MATCH ADJACENT SURFACE. 8. ISOLATED GROUND CIRCUITS SHALL BE INSTALLED IN SEPARATE CONDUIT FROM NORMAL POWER CIRCUITS. EACH IG CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AND INSULATED GROUND WIRE. THE GROUND WIRE SHALL BE CONTINUOUS BACK TO THE PANEL AND CONNECTED TO THE GROUND BUS WITHIN THE PANEL IG RECEPTACLES SHALL BE HUBBELL NO. IG -5362, OR APPROVED EQUAL 9. CORE BORE FLOOR SLAB AND INSTALL CONDUIT WITH PULLWIRE. PROVIDE BUSHING AT EACH END. PATCH AND REPAIR FLOOR TO MATCH EXISTING CONDITION. COORDINATE WORK WITH MALL OPERATIONS MANAGER. 10. SEE EQUIPMENT SCHEDULE FOR MECHANICAL EQUIPMENT INFORMATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. 11. PROVIDE A 1 1/2" CONDUIT FOR DATA ONES FROM CASHWRAP. COORDINATE WITH TENANT'S PROJECT MANAGER. 12. PROVIDE DEVICES SHOWN IN BACKROOM. COORDINATE WITH TENANT'S PROJECT MANAGER. 13. PROVIDE A DUPLEX RECEPTACLE AND LOW VOLTAGE JUNCTION WITH 1"C. WITH PULL STRING, STUB UP ABOVE CEIUING IN ACCESSIBLE LOCATION. VERIFY EXACT MOUNTING LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. 14. NOT USED. 15. PROVIDE 120 VOLT CONNECTION TO SENSORMATIC SYSTEM. COORDINATE EXACT REQUIREMENTS WITH TENANT'S PROJECT MANAGER. 16. NOT USED. 17. NOT USED. 18. PROVIDE DEVICE IN CEILING FOR LOSS PREVENTION REQUIREMENT. COORDINATE WITH TENANT'S PROJECT MANAGER. 19. ALL CONDUITS ROUTED TO FLOOR FIXTURES SHALL BE STUBBED UP AT 0' -4" AFF. INSTALL BUSHING AT TOP AND PROVIDE PULL STRING.. 20. TENANT'S A/V VENDOR SHALL FURNISH AND INSTALL CEIUNG MOUNTED SPEAKERS AND RELATED WIRING AS INDICATED ON PLAN. COORDINATE WITH TENANT'S PROJECT MANAGER. 21. PROVIDE SERVICE DOOR BUZZER SYSTEM: EDWARDS: 340- 4G5 -24VAC BUZZER, ONE (1) NEW ANNUNCIATOR LOCATED AT THE CASHWRAP AND ONE (1) BUZZER IN THE OFFICE, 852 WEATHERPROOF PUSHBUTTON, 592 TRANSFORMER. BUZZER SYSTEM WIRE NEED NOT BE INSTALLED IN CONDUIT UNLESS REQUIRED BY LANDLORD OR LOCAL AUTHORITY. 22. RECEPTACLES IN THE SALES AREA SHALL BE LOCATED 12' -O" ON CENTER. FIELD VERIFY EXACT LOCATION. 23. NOT USED. 24. PROVIDE FLUSH MOUNTED J- BOX AT 18" AFF AT LVS STATION IN BACKROOM. J -BOX SHALL HAVE (2) 1" CONDUITS STUBBED UP ABOVE CEIUNG TO ACCOMODATE LOW VOLTAGE WIRING FROM SALES AREA LVS STATION(S). COORDINATE WITH TENANT PROJECT MANAGER. 25. NOT USED. 26. NOT USED. 27. ELECTRICAL CONTRACTOR SHALL PROVIDE A 3/4" CONDUIT WITH PULLSTRING STUBBED UP ABOVE CEILING FOR LVS WIRING BY TENANT. CONDUIT SHALL BE CUT FLUSH TO FACE OF WALL AT 18" A.F.F., AND NIPPLE SHALL BE INSTALLED 28. PROVIDE RECEPTACLE AND UGHT SWITCH AT VAV BOX UNITS. PROVIDE PORCELAIN SOCKET WITH (1) 60WA19 LAMP, MOUNT NEAR ACCESS PANEL. VERIFY EXACT LOCATION WRH MECHANICAL CONTRACTOR. LA.8 POWER PLAN H H 1 1 E A I INIMMIMINIIII•11111•111•1111111IMEIMINIIIIMMIRIIIIMIEM11, � ! ►I 0 1 2 4 8 FEET LAV NOTE ALL CONDUITS AND CABLE PROVIDED BY ELECTRICAL CONTRACTOR. ALL CONDUITS TO RUN WITHIN FIXTURE FROM DEMISING WALL ADJACENT TO CASHWRAP. SLAB CORE BORING NOT REQUIRED. NOTE: SEE FLOOR PLAN FOR CORRECT ORIENTATION. NOTE: VERIFY CASH WRAP ELECTRICAL REQUIR ENTS WITH TENANT PROJECT MANAGER. UNES #1 AND 1 2 FOR TELEPHONE UNES 2 UNE RJ -141 TELEPHONE JACK. LA -6 LA -2 Q " - i 0 D // DEDICATED DUPLEX OUTLET IN AN ACCESSIBLE LOCATION FOR FUTURE LOSS PREVENTION. LA -6 LA- RJ -45 TELEPHONE JACK FOR DATA UNES 1 1/2" CONDUIT WITH PULLSTRING FROM POS CABINET WITHIN STOCKROOM FOR DATA UNE. TENANT'S VENDOR TO PULL DATA CABLE. 3/4" CONDUIT WITH PULLSTRING FOR TELEPHONE SYS i 1. EXTEND TO TELEPHONE BACKBORAD IN STOCKROOM. LA -8 ,}o LA -8 ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX IN CASH WRAP FOR ALTRONIX ALTV248 CAMERA POWER SUPPLY UNIT. COORDINATE NUMBER AND LOCATION OF CAMERAS WITH TENANT'S PROJECT MANAGER T ( 7\ CASH WRAP POWER PLAN 7 A 8 FEET 1/4" = 1' -0" Il il 1♦ Is -■r-� I 171 LA 1/4" = 1' -0" L i (1) 1 1/2" CONDUIT WITH PULLSTRING FOR A/V EQUIPMENT. RUN WITHIN MILLWORK AND STUB ABOVE CEIUNG TO AN ACCESSIBLE LOCATION. BUSH TOP END. (2) 3/4" CONDUIT AT CASHWRAP AND PANELBOARD: (1) CONDUIT FOR IG RECEPTACLES CLEAN POWER AND (1) CONDUIT FOR RECEPTACLES DIRTY POWER. RUN CONDUIT WITHIN MILLWORK OF CASHWRAP. RECE;' .'r `' CITY OF TUKWILA MAP 0 3 2008 PERMIT CENTER 9 „ Z Q O ab N O a 1 IA WI ea ea I SHEET NUMBER E -2 SHEET 16 OF 17 No.: LA LOCATION: STOCKROOM MOUNTING SURFACE RATED AIC: 120/208 VOLT 3 PHASE, 4 WIRE 10,000 MAIN: CB 100 AMP CIRCUIT DESCRIPTION KVA CB No. HL A B C HL No. CB KVA CIRCUIT DESCRIPTION S.F. DOWN LT.(D, PL) 0.3 20/1 1 * X * 2 20/1 0.4 CASH REGISTER NEON LIGHTS (N) 0.8 20/1 3 0.0 X * 4 20/1 0.4 CASH REGISTER SALES DOWN LT. (D1) 0.4 20/1 5 BUZZER X * 6 20/1 1.0 CASHWRAP REC. SPARE 0.0 20/1 7 X 8 20/1 0.8 SENSORMATIC / LOSS P. SALES DOWN LT. (D1) 0.4 20/1 9 FLOOR RECEPTACLE X • 10 20/1 0.6 SHOW WINDOW REC. TOILET LTGJFAN 0.2 20/1 11 X Ago) LA-la 12 20/1 t2 STORE SIGN WH -1 1.7 20/1 13 TENANT EC. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. X 14 20/1 1.2 SALES AREA REC. STOCKRM REC. 1.0 20/1 15 X 16 20/1 t2 SALES AREA REC. TOILET GFI REC. 0.2 20/1 17 X 18 20/1 1.0 SALES AREA REC. SPARE 0.0 20/1 19 X * 20 20/1 02 LVS STATION REC SPARE 0.0 20/1 21 X 22 20/1 0.2 VENTED CABINET REC. SPARE 0.0 20/1 23 X * 24 20/1 0.4 AN RACK REC. SPARE 0.0 20/1 25 X 26 20/1 0.4 TELEPHONE REC. SPARE 0.0 20/1 27 X * 28 20/1 0.4 P.O.S STATION SPARE 0.0 20/1 29 X 30 20/1 0.4 WORK/FOLDING TABLE SPARE 0.0 20/1 31 X 32 20/1 0.6 HVAC REC. /LTG. SPARE 0.0 20/1 33 X 34 20/1 0.1 TIMESWITCH/ BUZZER SPARE 0.0 20/1 35 X 36 20/1 0.0 SPARE SPACE 37 X 38 SPACE SPACE 39 X 40 SPACE SPACE 41 X 42 SPACE Al B I C . CONNECTED LOAD: CALCULATED CODE DEMAND LOAD 47 AMPS MAX 15.5 KVA 5.6 5.1 4.8 16.3 KVA 45 AMPS No.: HA LOCATION: STOCKROOM MOUNTING SURFACE RATED AIC: 277/480 VOLT 3 PHASE 4 WIRE 22,000 MAIN: LO 225 AMP CIRCUIT DESCRIPTION KVA CB No. HL A B C HL No. CB KVA CIRCUIT DESCRIPTION EXIT /EM /NL (EM/A,E) 0.4 20/1 1 * X 1.00 2 MOTORS 5.6 1.25 SALES AREA LTG.(A) 1.6 20/1 3 0.0 X 0.0 4 50/3 5.1 30 KVA TRANSFORMER SALES AREA LTG.(A) 1.4 20/1 5 BUZZER X TOTAL 6 PUSHBUTTON CONTROL STATION - WALL MOUNTED 4.8 LOW VOLTAGE CONTROL TRANSFORMER SPARE 0.0 20/1 7 X 8 2.5 Ai STOCKROOM LTG. 0.4 20/1 9 FLOOR RECEPTACLE X • 10 20/3 1.7 VAV -1 SPARE 0.0 20/1 11 X Ago) LA-la 12 9 B -16 1.7 NOTES: 1. ALL IG RECEPTACLES SHALL BE ORANGE. 2. A SQUARE ENCLOSING A WIRING DEVICE SYMBOL INDICATES A FLUSH FLOOR DEVICE. SPARE 0.0 20/1 13 TENANT EC. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. X 14 1.7 SPARE 0.0 20/1 15 X 16 20/3 , 1.7 VAV -2 SPARE 0.0 20/1 17 X 18 2.5 SPACE 19 X 20 SPACE SPACE 21 X 22 SPACE SPACE 23 X 24 SPACE SPACE 25 X 26 SPACE SPACE 27 X 28 SPACE SPACE 29 X 30 SPACE A ( B I C _ CONNECTED LOAD: CALCULATED CODE DEMAND LOAD 38 AMPS MAX 31.1 KVA 10.2 10.5 10.4 34.4 KVA 41 AMPS LA - LOAD SUMMARY CONN. KVA DEM FACT. DEM. KVA SIGN / NEON SIGN 1.2 1.25 1.5 LIGHTING 2.1 1.25 2.6 TRACK LIGHTING ** 0.0 1.00 0.0 RECEPTACLES 7.9 1.00 7.9 WATER HEATER 1.7 1.00 1.7 MISCELLANEOUS 2.6 1.00 2.6 MOTORS 0.0 1.25 0.0 KITCHEN EQUIPMENT 0.0 0.65 0.0 HVAC (LARGEST) 0.0 1.25 0.0 HVAC (REMAINING) 0.0 1.00 0.0 BUZZER TOTAL 15.5 PUSHBUTTON CONTROL STATION - WALL MOUNTED 16.3 LOW VOLTAGE CONTROL TRANSFORMER TIME SWITCH HA - LOAD SUMMARY CONN. KVA DEM FACT. DEM. KVA SIGN / NEON SIGN 1.2 1.25 1.5 LIGHTING 5.9 1.25 7.4 TRACK LIGHTING 0.0 1.00 0.0 RECEPTACLES 7.9 1.00 7.9 WATER HEATER 1.7 1.00 1.7 MISCELLANEOUS 2.6 1.00 2.6 MOTORS 0.0 1.25 0.0 KITCHEN EQUIPMENT 0.0 0.65 0.0 HVAC (LARGEST) 5.9 1.25 7.4 HVAC (REMAINING) 5.9 1.00 5.9 BUZZER TOTAL 31.1 PUSHBUTTON CONTROL STATION - WALL MOUNTED 34.4 LOW VOLTAGE CONTROL TRANSFORMER TIME SWITCH ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION SWITCH - SINGLE POLE TOGGLE SWITCH -- SINGLE POLE KEY - OPERATED SWITCH - SINGLE POLE WITH PILOT LIGHT SWITCH -- 3 WAY WALL RECEPTACLE - DUPLEX STRAIGHT BLADE WALL RECEPTACLE - FOURPLEX STRAIGHT BLADE J RECEPTACLE - DUPLEX STRAIGHT BLADE, ISOLATED GROUND RECEPTACLE - FOURPLEX STRAIGHT BLADE, ISOLATED GROUND RECEPTACLE - DUPLEX STRAIGHT BLADE, GROUND FAULT INTERRUPTER, WEATHER PROOF SPLIT CIRCUIT RECEPTACLE SPECIAL PURPOSE RECEPTACLE I MULTI - OUTLET ASSEMBLY (PLUGMOLD) TELEPHONE OUTLET - WALL MOUNTED DATA OUTLET a MOTOR - HORSEPOWER, VOLTAGE AND PHASE AS NOTED ON DRAWINGS NON -FUSED DISCONNECT SWITCH - SIZE AS NOTED ON DRAWINGS NON -FUSED DISCONNECT SWITCH - SIZE AS NOTED ON DRAWINGS FUSED DISCONNECT SWITCH - SIZE AS NOTED ON DRAWINGS MAGNETIC MOTOR STARTER - SIZE AS NOTED ON DRAWINGS JUNCTION BOX - WALL, CEILING SWITCHBOARD OR PANELBOARD TELEPHONE BACKBOARD BUZZER BELL OR CHIME PUSHBUTTON CONTROL STATION - WALL MOUNTED LOW VOLTAGE CONTROL TRANSFORMER TIME SWITCH CONTACTOR -_..- -I THERMOSTAT (BY MECHANICAL CONTRACTOR OR AS INDICATED) CONDUIT - CONCEALED ABOVE CEILINGS, IN WALLS IN FINISHED AREAS, OR EXPOSED IN UNFINISHED AREAS CONDUIT HED - G RAD E IN OR BELOW FLOOR SLAB OR BELOW FINIS Ai CONDUIT HOMERUN TO PANEL - CROSSMARKS INDICATE NUMBER OF CONDUCTORS. NO CROSSMARKS INDICATES 2 CONDUCTORS. DOT ON CROSSMARKS INDICATES EQUIPMENT ISOLATED GROUNDING CONDUCTOR. El FLOOR RECEPTACLE • FLUSH FLOOR TELEPHONE OUTLET Q a UNDER FLOOR STUB UP SPEAKER EXIT LIGHT EMERGENCY FIXTURE Ago) LA-la TOP LETTER INDICATES LIGHT FIXTURE TYPE, ( ) INDICATES NUMBER OF FIXTURES. REFER TO UGHT FIXTURE SCHEDULE. BOTTOM LETTER AND NUMBER INDICATES PANELBOARD DESIGNATION AND CIRCUIT NUMBER. LOWER CASE LETTER INDICATES SWITCH DESIGNATION. 9 B -16 LETTER AND NUMBER NEXT TO ALL DEVICES AND CONDUIT STUB -UPS INDICATES PANELBOARD DESIGNATION AND CIRCUIT NUMBER RESPECTIVELY. NOTES: 1. ALL IG RECEPTACLES SHALL BE ORANGE. 2. A SQUARE ENCLOSING A WIRING DEVICE SYMBOL INDICATES A FLUSH FLOOR DEVICE. NOTE; TENANT EC. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. NOTES: RISER DIAGRAM BASED ON INFORMATION AVAILABLE. ELECTRICAL CONTRACTOR TO VERIFY ALL EXISTING EQUIPMENT BEING REUSED IS ADEQUATE AND UP TO CURRENT CODES. ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL ELECTRICAL EQUIPMENT PRIOR TO BIDDING JOB. MALL DISTRIBUTION NOTE; TENANT PANELBOARDS, DISTRIBUTION EQUIPMENT, AND OVER CURRENT DEVICES SHALL BE DESIGNED TO SAFELY WITHSTAND THE AVAILABLE FAULT CURRENTS, RATED IN RMS SYMMETRICAL AMPERES. NOTE TENANT'S ELECTRICAL CONTRACTOR TO COORDINATE AIC RATINGS OF ALL EQUIPMENT ". NOT TO SCALE POWER RISER DIAGRAM RISER DIAGRAM NOTES LANDLORD'S EXISTING 277/480 VOLT, 3PH, 4WIRE MIAN DISTRIBUTION BOARD TO REMAIN. Q EXISTING METER AND METER SOCKET BY LANDLORD TO REMAIN. Q EXISTING 200A /3P CIRCUIT BREAKER BY LANDLORD TO REMAIN. Q EXISTING 2 "C. -4 #3/0 THHN -CU. & 1 #6 GROUND WIRE BY LANDLORD TO REMAIN. FIELD VERIFY EXACT STUB -IN LOCATION. Q EXISTING 200A /3P DISCONNECT SWITCH WITH (3) 200A FUSES BY LANDLORD TO REMAIN. Q 2 "C -4#3/O THHN -CU. & 1#6 GROUND WIRE Q 1 "C -3 #8 THEN -CU. a FLOOR MOUNTED 30 KVA TRANSFORMER. 10 1#8 BARE COPPER GROUND AND TIE TO BUILDING STEEL PER NEC. 11 1 1/4 "C -4 #3 THHN -CU. 12 PANEL "LA ". SEE PANELBOARD SCHEDULE FOR MORE INFORMATION. 13 TIMESWTTCH (TS1). SEE SHEET E1 FOR SPECIFICATION. 14 CONTACTORS (C1), (C2) & (C3). SEE SHEET E1 FOR SPECIFICATION. 15 AVAILABLE FAULT CURRENT PER LANDLORD PROVIDED INFORMATION. ELECTRICAL SPECIFICATIONS 16000 - GENERAL PROVISIONS 0.01 PERFORMANCE: ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED, INDICATED AND REQUIRED UNLESS OTHERWISE NOTED, INCLUDING FINAL CONNECTIONS, IN A WORKMANLIKE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE TRADE. 0.02 SITE EXAMINATION: EXAMINE SITE BEFORE BIDDING. CLAIMS FOR EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDITIONS SHALL NOT BE ALLOWED OR APPROVED. 0.03 JOB SITE CONDMONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0.04 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECESSARY FOR COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.05 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSER, BONDING, AND INSURANCE, AND PERFORM OTHER ADMINISTRATIVE FUNCTIONS, AS REQUIRED. 0.06 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES. 0.07 COORDINATION: CONFORM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HEREIN. REFER ALSO TO STRUCTURAL AND MECHANICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER TRADES. 0.08 ROOF PENETRATIONS: COORDINATE WITH LANDLORD. 0.09 MECHANICAL SUBSTITUTIONS: INVOICE MECHANICAL CONTRACTOR, NOT TENANT, FOR COSTS INCURRED DUE TO SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.10 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.11 REFERENCE STANDARDS: COMPLY WITH NEC, AND APPLICABLE STANDARDS OF NFPA, ANSI, NEMA, AND UL, EXCEPT AS SUPERSEDED BY LOCAL AUTHORITY. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED CODE MINIMUM REQUIREMENTS. 0.12 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF LOCAL CODES, LANDLORD, SERVING UTILITY, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD, LOCAL AUTHORITY, AND OTHERS AS REQUIRED. 0.13 SCHEDULE: ORDER EQUIPMENT WITHIN 5 DAYS OF RECEIPT OF CONTRACT TO MAINTAIN CONSTRUCTION SCHEDULE. 0.14 TEMPORARIES: PROVIDE ALL TEMPORARY SERVICE, LIGHTING AND POWER FOR ALL TRADES AS REQUIRED. REMOVE ALL TEMPORARIES BY THE TIME OF PROJECT COMPLETION. 0.15 MATERIALS AND EQUIPMENT: PROVIDE NEW, UL LISTED, COMMERCIAL GRADE MATERIALS, DEVICES, EQUIPMENT, AND FIXTURES, SUITABLE FOR ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPUANT WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION, AND APPROVED BY THE ENGINEER. COMPLY WITH CURRENT CODES. 0.16 INSTALLATION: INSTALL ALL MATERIALS, EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURERS' RECOMMENDATIONS. 0.17 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT. VERIFY PROPER MOTOR ROTATION OF ALL EQUIPMENT. 0.18 0 & M MANUALS: AT COMPLETION OF PROJECT, PROVIDE TO TENANT ALL OPERATING AND MAINTENANCE MANUALS AND INFORMATION FOR MATERIAL, EQUIPMENT AND SYSTEMS INSTALLED UNDER THIS CONTRACT. 0.19 CORRECTIVE PERIOD: PROVIDE A CORRECTIVE PERIOD FROM DATE OF FINAL ACCEPTANCE OF NOT LESS THAN ONE (1) YEAR FOR THE ENTIRE INSTALI.ATION, DURING WHICH PERIOD UNCONDITIONALLY MAKE GOOD ANY DEFECTS IN MATERIALS OR WORKMANSHIP WITHOUT COST TO TENANT. 0.20 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT AND RACEWAY LOCATIONS TO AVOID CONFLICTS WITH OTHER CONSTRUCTION. 0.21 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE THESE SPECIFICATIONS. 0.22 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS AND REQUIREMENTS. 0.23 PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS SPECIFIED MAY BE REQUIRED FOR THIS PROJECT. 0.24 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ERRORS, DISCREPANCIES OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, FAILING SUCH NOTICE, BE RESPONSIBLE FOR CORRECTING SAME. 0.25 CERTIFICATION: PROFESSIONAL ENGINEER CERTIFICATION OF THESE DOCUMENTS DOES NOT EXTEND TO STANDARDIZED DESIGN OR INSTALLATION GUIDELINES PREPARED BY OTHERS AND REQUIRED BY A THIRD PARTY TO BE INCLUDED HEREON. 0.26 DEFINITIONS: THE TERMS LISTED BELOW ARE DEFINED AS FOLLOWS WHEN USED IN DMSION 16 AND ONLY DMSION 16. A. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELIVER TO THE JOB SITE IN NEW CONDITION AND GUARANTEE. B. INSTALL: RECEIVE AT THE JOB SITE, UNLOAD, STORE, SET IN PLACE, CONNECT, PLACE IN OPERATION AND GUARANTEE. C. PROVIDE: FURNISH AND INSTALL. D. REMOVE REMOVE INSTALLATION BACK TO NEXT REMAINING POINT OF USE. 16100 - MATERIALS 1.01 RACEWAY: CONTINUOUS SYSTEM, 1/2" MINIMUM EMT EXCEPT: 3/4" MINIMUM RNC WITH GROUND CONDUCTOR WHERE EMBEDDED IN CONCRETE OR MASONRY; 3/4" MINIMUM GALVANIZED RMC OR IMC WHERE EXPOSED TO WEATHER (ALSO PERMITTED WHERE EMBEDDED IN CONCRETE OR MASONRY); AND FMC (OR LTFMC IF WET LOCATION) FOR SHORT FINAL CONNECTIONS TO LIGHTING FIXTURES, TRANSFORMERS, AND MECHANICAL EQUIPMENT. 1.02 IG RACEWAY: PROVIDE SEPARATE RACEWAY SYSTEM FOR IG CIRCUITS. 1.03 RACEWAY INSTALLATION: CONCEAL RACEWAY IN FINISHED SPACES. ROUTE SQUARE WITH BUILDING UNES AND SUPPORT PER NEC. DO NOT ATTACH TO OR PENETRATE HVAC DUCTS. MAINTAIN HEADROOM AND EQUIPMENT AND FLUE CLEARANCE. FIRE /SMOKE - SEAL PENETRATIONS OF RATED CONSTRUCTION. 1.04 RACEWAY ADJUSTMENTS: WHERE INDMDUAL HOME RUNS ARE SHOWN FOR CLARITY, COMBINE AND ADJUST RACEWAY SIZE PER FIELD CONDMONS. 1.05 WIRE: TYPE THHN, COPPER ONLY, 12AWG MINIMUM, STRANDED FOR 8AWG AND LARGER. LV WIRING FOR EMERGENCY UGHTING, 10AWG MINIMUM. USE OF ALUMINUM CONDUCTORS SHALL NOT BE ALLOWED. 1.06 COLOR CODE: COLOR CODE ENTIRE WIRING SYSTEM FROM SERVICE DISCONNECT OR TRANSFORMER THROUGHOUT ALL BRANCH CIRCUITS AS FOLLOWS: FOR 120/208 VOLT SYSTEM, PHASE A - BLACK, PHASE B - RED, PHASE C - BLUE, NEUTRAL - WHITE; FOR 277/480 VOLT SYSTEM, PHASE A - BROWN, PHASE B - ORANGE, PHASE C - YELLOW, NEUTRAL - WHITE WITH TRACER OR GRAY; GROUNDING CONDUCTOR - GREEN. 1.07 WIRE SIZE WHERE WIRES ARE SIZED PER 60 DEG. C TEMPERATURE RATING FOR SIZES UP TO 1 AWG, SUBJECT TO COMPUANCE WITH EQUIPMENT UL USTING, AND APPROVAL OF LOCAL AUTHORITY AND ENGINEER, SUCH WIRES MAY BE REDUCED TO 75 DEG. C RATED SIZE, WITH RACEWAY SIZE ADJUSTED ACCORDINGLY. WIRE SIZE PER 90 DEG. C TEMPERATURE RATING IS NOT APPROVED. 1.08 VOLTAGE DROP: FOR CONDUCTORS SIZED PER NEC ON DRAWINGS, INCREASE SIZE BY NUMBER OF STANDARD SIZES SHOWN IN TABLE TO COMPENSATE FOR VOLTAGE DROP. CONTACT ENGINEER FOR ASSISTANCE IF CIRCUIT LENGTH FROM SOURCE TO LOAD EXCEEDS MAXIMUMS SHOWN. CCT VOLTS /PH 120/1 120/1 208/3 OR 277/1 208/3 OR 277/1 480/3 480/3 1.09 TYPE MC CABLE: MC CABLE EQUIPPED WITH A GREEN INSULATED GROUND PERMITTED FOR BRANCH CIRCUITS IN CONCEALED LOCATIONS ONLY SUBJECT TO APPROVAL OF TENANT, LANDLORD, AND LOCAL AUTHORITY. 1.10 SPLICES: SPUCE ONLY IN ACCESSIBLE JUNCTION BOXES, USING "WIRENUT" CONNECTORS FOR 8AWG AND SMALLER, OR MECHANICAL COMPRESSION CONNECTORS WITH INSULATION KIT FOR 6AWG AND LARGER. 1.11 BOXES: NEMA 051 IN INTERIOR DRY LOCATIONS, CAST WEATHERPROOF TYPE IN WET LOCATIONS. 1.12 WALL SWITCHES: FED SPEC W -S -896, AC GENERAL USE, 20 AMP, 120 -277 VOLT, TOGGLE HANDLE. INSTALL 48" A.F.F TO CENTER. 1.13 WALL RECEPTACLES: FED SPEC W -C -596, NEMA 5 -20R CONFIGURATION OR AS REQUIRED. PROVIDE 10 (ISOLATED GROUND) AND GFCI /WP (GROUND -FAULT CIRCUIT INTERRUPTER) RECEPTACLES WHERE APPROPRIATE OR INDICATED. INSTALL 18" A.F.F TO CENTER, OR AS INDICATED. 1.14 WALL PLATES: SMOOTH PLASTIC. KITCHEN AREA: STAINLESS STEEL 1.15 WALL DEVICE AND PLATE COLOR: MATCH ADJACENT SURFACE, OR AS DIRECTED BY ARCHITECT. PROVIDE ORANGE IG RECEPTACLES. 1.16 MANUFACTURED WIRING SYSTEMS: PERMITTED FOR BRANCH CIRCUITS SUBJECT TO APPROVAL OF TENANT, LANDLORD, AND LOCAL AUTHORITY. 1.17 GROUNDING: PROVIDE CONTINUOUS, PERMANENT, AND EFFECTIVE GROUNDING SYSTEM. GROUND SEPARATELY DERIVED SYSTEMS TO NEAREST EFFECTIVELY GROUNDED BUILDING STRUCTURAL STEEL 16400 - EQUIPMENT CCT LENGTH FT. UPSIZE 75 -150 1 150 -200 2 150 -200 1 200 -250 2 300 -450 1 450 -550 2 4.01 DISCONNECT SWITCH: NEMA KS1, GENERAL DUTY, 3 POLE, S/N IF NEUTRAL IS PRESENT, NEMA 3R ENCLOSURE IF OUTDOORS, LOCK -OFF, NON- FUSIBLE UNLESS INDICATED WITH FUSES. 4.02 DRY -TYPE TRANSFORMER: NEMA ST20, 480 :208Y120 CONNECTED, 115 DEGREE RISE, KVA RATING AS INDICATED. INSTALL USING VIBRATION ISOLATORS. STATES WITH REQUIREMENTS FOR ENERGY EFFICIENT TRANSFORMERS PROVIDE NEMA TYPE -TP1, 150' RISE. RE -USE EXISTING IF APPLICABLE 4.03 PANELBOARD: NEMA PB1 AS SCHEDULED, 20" WIDE SECTION, 225 AMP BUS (100 AMP BUS PERMITTED IF LESS THAN 30 BRANCH POLES). PROVIDE GROUND BUS FOR IG CIRCUITS. INSTALL PER NEMA PB1.1. PROVIDE TYPEWRITTEN BRANCH CIRCUIT DIRECTORY. LOAD CENTERS NOT APPROVED. RE -USE EXISTING IF APPLICABLE AND STILL MEETS CODE REQUIREMENTS. ALL COMBINATIONS OF EQUIPMENT AND MAIN /BRANCH OVERCURRENT PROTECTION SHALL BE FULLY RATED AEC. (NEC 110.9) 4.04 CIRCUIT BREAKER: NEMA AB1 AS SCHEDULED, BOLT -ON, CENTER TRIP, SWD IF SINGLE POLE, COMMON TRIP IF MULTI -POLE, HACR IF REQUIRED BY LOAD. MATCH EXISTING EQUIPMENT. 4.05 FUSE UL CLASS J. WHEN FUSING EXISTING EQUIPMENT FUSES SHALL BE CURRENT UMITING AND MATCH EXISTING FUSE MANUFACTURER PROVIDE 3 SPARE OF EACH SIZE AND TYPE INSTALLED. 4.06 MAGNETIC MOTOR STARTER: NEMA ICS2, FVNR, SIZE PER MOTOR REQUIREMENTS BUT SIZE 0 MINIMUM, NEMA 3R ENCLOSURE IF OUTDOORS. PROVIDE CLASS 20 HEATERS PER ACTUAL MOTOR NAMEPLATE DATA. PROVIDE 120VAC OR 24VAC FUSED CONTROL CIRCUIT AS REQUIRED. 4.07 MANUAL MOTOR STARTER: NEMA RATED, FHP, SINGLE SPEED, TOGGLE OPERATED, MANUAL RESET OVERLOAD, NEMA 1 ENCLOSURE. 16500 - UGHTING 5.01 TENANT - FURNISHED EQUIPMENT: FOR UGHT FIXTURES AND AUXILIARY ITEMS SCHEDULED AS FURNISHED BY TENANT, RECEIVE, PROTECT, INSTALL, CLEAN, AND LAMP UGHT FIXTURES AS SCHEDULED, OR EQUAL. 5.02 CONTRACTOR - FURNISHED EQUIPMENT: FOR LIGHT FIXTURES SCHEDULED AS FURNISHED BY CONTRACTOR, FURNISH AND INSTALL COMPLETE, OR APPROVED EQUAL. 5.03 ACCESSORIES: PROVIDE ACCESSORIES, INCIDENTAL MATERIALS AND MOUNTING HARDWARE AS REQUIRED. 5.04 LOCATION: REFER ALSO TO ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING DETAILS. 5.05 INSTALLATION: PROPERLY INSTALL AND SUPPORT ALL FIXTURES PLUMB AND TRUE, AND FREE OF UGHT LEAKS. CONFORM TO MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY PRACTICE LEAVE PROTECTIVE FILM IN PLACE ON FIXTURES UNTIL FINAL CLEAN -UP. INSTALL UGHT FIXTURES IN RATED CEILINGS TO MAINTAIN THE RATING OF CEILING. 5.06 EMERGENCY LIGHTING: PROVIDE AND LOCATE EMERGENCY UGHTING TO MEET LOCAL REQUIREMENTS. 5.07 FLUORESCENT FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE ELECTRONIC HPF, RAPID START, PARALLEL LAMP OPERATION, CBM, TYPE 1, CLASS P, SOUND RATED A, THD[20 %, CCFC1.5, NAECA COMPUANT WHERE APPLICABLE, ENERGY SAVING BALLASTS. 5.08 RECESSED INCANDESCENT FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE FMC AND 150 DEGREE C FIXTURE WIRE FROM LAMP HOUSING TO INDEPENDENT BRANCH CIRCUIT OUTLET BOX. 5.09 HID FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE ANSI C82.4 COMPLIANT, HPF, ENCAPSULATED BALLASTS, ADVANCE SERIES 738 OR EQUAL 5.10 FINAL ADJUSTMENT: AFTER TRADE FIXTURES ARE INSTALLED BY OTHERS, CLEAN ALL LIGHTING FIXTURES, REPLACE ALL EXPIRED LAMPS, AND ADJUST DIRECTIONAL UGHTING AS DIRECTED BY TENANT AND ARCHITECT. 5.11 SIGN DISCONNECT: PROVIDE DISCONNECT SWITCH IN ACCESSIBLE CEIUNG SPACE FOR STORE SIGN AND MAKE FINAL CONNECTIONS. VERIFY LOCATION IN FIELD. SIGN FURNISHED AND INSTALLED BY OTHERS. COORDINATE ALL REQUIREMENTS PRIOR TO BID. 16700 - SYSTEMS 7.01 DATA SYSTEM ROUGH -IN: PROVIDE DEDICATED CONTINUOUS EMT RACEWAY SYSTEM WITH PULL WIRE FROM DATA SYSTEM EQUIPMENT LOCATION TO ALL DATA SYSTEM OUTLETS. SIZE AS SPECIFIED ON DRAWINGS, 3/4" MINIMUM. FOR NON- PLENUM ACCESSIBLE CEILING SPACES, AND WHERE APPROVED BY TENANT, LANDLORD, AND LOCAL AUTHORITY, BUSHED RACEWAY STUBS FROM OUTLET BOXES TO CEIUNG SPACE ARE PERMITTED IN UEU OF CONTINUOUS SYSTEM OR AS NOTED. FOR WALL OUTLETS PROVIDE 4" SQUARE OUTLET BOX WITH SINGLE GANG ADAPTER RING AND BLANK PLATE. FOR FLOOR OUTLET PROVIDE FLOOR BOX AS ELSEWHERE SPECIFIED AND BLANK PLATE. 7.02 TELEPHONE SYSTEM ROUGH -IN: PROVIDE DEDICATED CONTINUOUS EMT RACEWAY SYSTEM WITH PULL WIRE FROM LANDLORD STUB -IN TO BACKBOARD, AND FROM BACKBOARD TO ALL TELEPHONE OUTLETS. SIZE AS SPECIFIED ON DRAWINGS, 3/4" MINIMUM. FOR NON- PLENUM ACCESSIBLE CEIUNG SPACES, AND WHERE APPROVED BY TENANT, LANDLORD, AND LOCAL AUTHORITY, BUSHED RACEWAY STUBS FROM OUTLET BOXES TO CEIUNG SPACE WHERE PERMITTED IN UEU OF CONTINUOUS SYSTEM OR AS NOTED. FOR WALL OUTLETS, PROVIDE 4" SQUARE OUTLET BOX WITH SINGLE GANG ADAPTER RING AND TELEPHONE PLATE. FOR FLOOR OUTLET PROVIDE FLOOR BOX AS ELSEWHERE SPECIFIED AND TELEPHONE PLATE. PROVIDE 3/4" FIRE- TREATED PLYWOOD BACKBOARD OF SIZE REQUIRED FOR TELEPHONE EQUIPMENT. PROMPTLY NOTIFY TENANT WHEN ROUGH -IN INSTALLATION IS COMPLETE. 7.03 SECURITY SYSTEM ROUGH -IN: PROVIDE CONTINUOUS RACEWAY SYSTEM WITH PULL WIRE AS INDICATED FOR INSTALLATION OF SECURITY SYSTEMS BY OTHERS. NOTE; FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. NOTE ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANT'S VENDOR. ** DEMAND PER NEC 410-101B AND 220 -12B TOTAL TRACK LENGTH FINT5TO LINE 2 ,- � LIN POINT OF DEMARCATION (MALI- TELEPHONE CLOSET OR STORE STOGKRom) (R01 LOVER ALINE 2 TEJHHONE BLOCK (6Y LOCAL T9. E:HONE PROVIDER) T -I LINE (Br TENANT) NO SCALE * HL = INDICATES HANDLE LOCK DEVICE ON CIRCUIT BREAKER(S) (E)=EXISTING EQUIPMENT TO REMAIN R145 JACK ** DEMAND PER NEC 410-101B AND 220 -12B TOTAL TRACK LENGTH * HL = INDICATES HANDLE LOCK DEVICE ON CIRCUIT BREAKER(S) (E)= EXISTING EQUIPMENT TO REMAIN TRAMS WORLD STORE PREMISES 1 000 0 0 0 O 0 0 0 O 0 0 0 (AT I5P LOCATION - PDS. MODE11) VOICE U1 51 AND 2 GATE60RY 5 DATA GABLE O 0 0 0 O 0 0 0 0 00 0 00 O 00 O 0 0 a o o I R114 1140 JACK AT GASH WRAP 0 0 0 000 8.114 TWD -LINE JACK IN STOCKROOM R1 I411V - !_LIVE .TACK IN STOCKROOM SINGLE LINE JACK AT ISP LOCATION ONLY (P05 MOP .H), BY TENANT R.114 m: -LINE JACK AT GASH WRAP OR ON 541.E5 FLOOR RJ 45 JACK (AT GASH WRAP) NOTE: ADDITIONAL TELEPHONE LOGATIONS WITHIN STORE MAY BE REWIRED. COORDINATE EXACT LOCATIONS AND GdUAN1W( WITH TENANT PROJECT MANASE - NOTE: ALL GABLE SHALL BE PL.BIJM RATED. TYPICAL TELEPHONE WIRING SETUP E -3 110 VAC OUTLET IN AN ACCESSIBLE LOCATION ABOVE CEIUNG WITHIN 10' -0" OF CONTROL MODULE. CONTROL MODULE IN AN ACCESSIBLE LOCATION ABOVE CEILING. SENSOR PLACEMENT SCHEME TYPICAL DETAIL 1 /4 " =1 '-O" CENTERLINE OF ROLL-UP GRILLE 1 LA -8 SENSORMATIC UNIT TYP. LA -8 (2)3/4 "C. 3/4 "C. I-0" POS /ISP MAIN WORK AREA NOTE: FOLDING SHELF CAN BE MOUNTED ON EITHER SIDE. HOLES ARE PRE-DRILLED Flan View SC14LB ur - f-0' • INSTALL ALL DEVICES ® IS' A.FF BEHIND FINISHED CABINET. ELECTRICAL CONTRACTOR TO LABEL J- BOXES. lb" SWINGABL SHELF N 'POS' DETAIL 1 /2" =1' -0" Elevation 8CM E' 1/2• - f� POWER/ IG PHONE OU 11 ETS ✓ RJI4(VOIGE) ✓ R..III(MODEM) R..145(PATA) PREDRILJ,.ED HOLES FOR POWER SUPPLY - BOTH SIDES POb•-1/ EQ. 8' -0" SEE E -2 FOR SPECIFIC KEYNOTES NOTE: SEE FLOOR PLAN FOR CORRECT ORIENTATION. NOTE: VERIFY SENSORMATIC INSTALLATION WITH TENANT'S PROJECT MANAGER PRIOR TO CONSTRUCTION. RECEIVED � CITY OF TUKV�A ',' Md 0 3 200$ -�t�� PERMIT CENTER ) SHEET NUMBER E -3 SHEET 17 OF 17