HomeMy WebLinkAboutPermit D08-118 - EXPRESS LINEN SERVICE - TENANT IMPROVEMENTEXPRESS LINEN SERVICE 14603 35 AV S D08 -118 Parcel No.: 2044000005 Address: 14603 35 AV S TUKW Suite No: Tenant: Name: EXPRESS LINEN SERVICE Address: 14603 35 AV S , TUKWILA WA Owner: Name: SIDHU JEET S Address: 2423 124TH PL NE , BELLEVUE WA 98005 Phone: Contact Person: Name: ANDY TEH Address: 1009 9 AV S , EDMONDS WA 98020 Phone: 425 7711192 Contractor: Name: MONARCH TRADING CORP Address: PO BOX 80563 , SEATTLE WA 98108 Phone: 206 - 763 -6161 Contractor License No: MONARTC065Q 1 doc: IBC -10/06 Citylif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT DESCRIPTION OF WORK: TI FOR CHANGE OF USE (RETAIL TO LAUNDRY (SERVICE): DEMOLITION PORTION OF INTERIOR NON - BEARING WALL FOR WALKWAYS, UPGRADE EXISTING RESTROOM TO HDCP RESTROOM. EXTERIOR RAMP AT ENTRANCE TO MEET ADA REQUIREMENTS. Value of Construction: $22,350.00 Fees Collected: $774.23 Type of Fire Protection: NONE International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: * *continued on next page ** Permit Number: D08 -118 Issue Date: 07/30/2008 Permit Expires On: 01/26/2009 Expiration Date: 03/06/2009 D08 -118 Printed: 07 -30 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: Signature: f / fic " 1 Print Name: AIA 0\ doc: IBC -10/06 City (*Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Number: D08 - 118 Issue Date: 07/30/2008 Permit Expires On: 01/26/2009 Date: 1 -3o I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Date:O 7 — ? .D ^ op This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -118 Printed: 07 -30 -2008 Parcel No.: 2044000005 Address: Suite No: Tenant: 14603 35 AV S TURIN • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us EXPRESS LINEN SERVICE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -118 ISSUED 03/04/2008 07/30/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 7: All wood to remain in placed concrete shall be treated wood. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 13: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 14: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 15: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: Cond -10/06 D08 -118 Printed: 07 -30 -2008 17: ** *FIRE DEPARTMENT CONDITIONS * ** • City of Tukwila 19: Maintain fire extinguisher coverage throughout. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 18: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 21: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 22: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 23: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 24: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 25: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 26: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 27: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 28: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not inunediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 29: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire doc: Cond -10/06 D08 -118 Printed: 07 -30 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 32: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 33: Local U.L. central station supervision is required. (City Ordinance #2051) 34: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #2051) 37: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #2051) 38: Fire alarm systems shall be maintained in an operative condition at all times. Fire alarm systems and their component parts shall be inspected and tested per manufacturer's specifications and N.F.P.A. 72 at a minimum frequency of every twelve months. A copy of inspection, test and maintenance records shall be forwarded to the Tukwila Fire Prevention Bureau. (NFPA 72 (10.2.1.1)) (City Ordinance #2051) 39: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (4.4.1.4.2.1)) 40: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 41: The reset code for the fire alarm panel or keypad shall be 1- 2- 3 -4 -5. The reset code shall not be changed without approval of the Fire Marshal. The reset code should be permanently posted at the keypad. (City Ordinance #2051) 42: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 43: Hazardous materials shall not be released into a sewer, storm drain, ditch, drainage canal, lake, river or tidal waterway, or upon the ground, sidewalk, street, highway or into the atmosphere. (IFC 2703.3) 44: Material safety data sheets for all hazardous materials on the premise shall be readily available on site for emergency personnel. (IFC 2703.4) 45: Visible hazard identification signs shall be placed at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit. Individual containers, cartons or packages shall be doc: Cond -10/06 D08 -118 Printed: 07 -30 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us conspicuously marked or labeled in accordance with nationally recognized standards. (IFC 2703.5) (NFPA 704)) 46: Incompatible materials in storage and storage of materials incompatible with materials in use shall be separated when the stored materials are in containers having a capacity of more than 5 pounds (2.268 kg) or 1/2 gallon (1.89 L). Separation shall be accomplished by: (1) Segregating incompatible materials storage by a distance of not less than 20 feet (6096 mm), (2) Isolating incompatible materials storage by a noncombustible partition extending not less than 18 inches (457.2 mm) above and to the sides of the stored material. (3) Storing liquid and solid materials in hazardous materials storage cabinets (see IFC 2703.9.8 (1 -4)), or (4) Storing compressed gases in gas cabinets or exhausted enclosures. Materials which are incompatible shall not be stored within the same cabinet or exhausted enclosure. 47: Spill containment systems or means to render a spill harmless to people or property shall be provided where a spill is determined to be a plausible event and where such an event would endanger people or property. (IFC 2701.3.3.4) 48: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 49: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 50: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 51: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 52: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 53: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 54: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. doc: Cond -10/06 * *continued on next page ** D08 -118 Printed: 07 -30 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: doe: Cond -10/06 D08 -118 Date: ordinances governing or local laws regulating Printed: 07 -30 -2008 Site Address: j l i—tit, A\l"" lj Tenant Name:_ 6 c/* L//. / 5g/2„ VI " s J Property Owners Name: Mailing Address: 4 Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: Contact Person: E -Mail Address: CITY OF TUKWILA) Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Perm No. Mechanical Penn' it Plumbing /Gas Permit Va. Public Works Permit No:;,` Project N"o Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Q T 41 00 0 O f Suite Number: New Tenant: .... Yes N ..No v Name: /WI 0 'r Mailing Address: /007 9' AV & E -Mail Address: frOnfeff Dy ( 1 Q:'Applications\Porms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh J 1GENERAL'CONTRACTORINFORMATION - ''.(Contractor' Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) City (For o we use. only) State Floor: City State Zip Fax Number: .4 Zip CONTACT. PERSON — who do we contact when your permit' is ready to be issued Day Telephone: (42-t) 7 7 / - / 11 Z_ t, MoIJO w 9 r Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: State CHITECT OF RECORD -All plans must lie wet -stamped by . Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: State State Zip Zip Company Name: Mailing Address: City Day Telephone: Fax Number: Zip Page 1 of 6 (. PERMIT INFOION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ ?i 2 3 . O Scope of Work (please provide detailed information): O• 0 Will there be new rack storage? E.... Yes 0 ►fib -io meer Pct- Existing Building Valuation: $ (3 0, 0 oD 414. Poi. t41,4ys , vP 6'RAD �. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Floor 2" 2' Floor 3L Floor Floors eme Ba tl Ac u tur drr Atl Detached Garage ed C d Cover d Dt k Addition to Existing Structure Type of stru ction per l BC T/ Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 7, loo Sf - Floor area of principal dwelling: �i ' Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: 2_ Handicap: I /_ •_ Will there be a change in use? Yes ❑ No If "yes ", explain: f4W2., c- T D� VIc FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: /C D - tf 4V(- , I Date Application Accepted: o*/ oaf ) ag Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: (n /O(C /D Day Telephone: (4-) /q Z— �D�/ m aS 14J'4 .9,3Po Z o City State Zip Date Application Expires: ot lok1l 01, Staff Initials: Page 6 of 6 Fixture Type: Qty Fixture Type: Qty , Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or wa � cooler (per head) :" ash fountain Gas piping outlets Bidet Food -waste grinder commercial Rec tor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, si a head trap Urinals Dishwasher, domestic, with independent drain Lavato Water Clos Building sewer or trailer park sewer Ra: 'water system — per in (inside building) Water heater an or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors epair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas ►'LI 1BING AND. GAS PIPIN(. _ ERMIT INFORMATION - 206 -43i. -670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plumbing work Valuation of Gas Piping work (c Scope of Work (please provide deta Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Sewer: Indicate type of plumbing fixtures and /or gas piping outlets be ' , installed and the quantity below: City State Zip Day Telephone: Fax Number: Expiration Date: Page 5 of 6 Parcel No.: 2044000005 Address: 14603 35 AV S TUKW Suite No: Applicant: EXPRESS LINEN SERVICE Receipt No.: R08 - 02790 Payee: THERESA PHAN ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City �f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1226 471.00 Account Code Current Pmts 000/322.100 000/386.904 RECEIPT 466.50 4.50 Total: $471.00 Permit Number: D08 -118 Status: APPROVED Applied Date: 03/04/2008 Issue Date: Payment Amount: $471.00 Initials: WER Payment Date: 07/30/2008 01:47 PM User ID: 1655 Balance: $0.00 5467 07/30 9710 TOTAL 471.00 doc: Receipt-06 Printed: 07 -30 -2008 Parcel No.: 2044000005 Permit Number: D08 -118 Address: 14603 35 AV S TUKW Status: PENDING Suite No: Applied Date: 03/04/2008 Applicant: EXPRESS LINEN SERVICE Issue Date: Receipt No.: R08 -00616 Initials: JEM Payment Date: 03/04/2008 12:16 PM User ID: 1165 Balance: $471.00 Payee: ANDY TEH TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8020 303.23 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 303.23 Total: $303.23 Payment Amount: $303.23 9392 03/04 9710 TOTAL 303.23 doc: Receiot -06 Printed: 03 -04 -2008 COMMENTS: Ai ! corre „to — PQ! 'V1 -r- LO Alit 1 ip.k pfes - A C 1..Sit2 A. 1 tAe,& -k prcJ/ _ M :, R1 ow LoVJ/N lk tA 'ire_ FT' t1\ Aer (. -efi- ti a A) 1 tl t? C /1 v r o ' i »i� ,. (A o ,AJ - A fr Jlo� ITTM1( 0 r W, A.r t e * Per M 1"5 , � .Sid OA_ Co RJ 4\ITPJ `va\K. ftr Date Wanted: ._ A-., ('S Id l/3 it kfA f `t2r J) r N f- b , �-- 7 Ce1i s r A' ;lvi,e404 s i -- o I J p t Deco p AC t, ' Su /r .t. DepAkt Project: ( -0 f i:'� )v-,J,4/0 Type of ln) , \ 6L, • A 0 A4 I4 Address! � D3 3 5 AVE J � ate Called: ./"...N Special Instructions: .. Date Wanted: d� 1 b p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Oaf -ihr PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. Inspect t: ' Date: G T El $60.00 REINSPECTION FEE EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Byd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: __ - y • ..� ..emu. �. COMMENTS: Type of Ins ection: P F,AM / Address. J 4 1663 35 4o S Date Called: Special Instructions: Date Wanted: a.m. 3-- 6 - a ��- iC ( 16'1i` /IAA f-P A. 6 A A z.( P.11 `` Fir r Ji 74- _- -_e f /- /1 ` r ( f CJ' 1 ,-_- 1 - 1 . i r\ i 1 Prolec ; / f s L /Ne'N /f � Type of Ins ection: P F,AM / Address. J 4 1663 35 4o S Date Called: Special Instructions: Date Wanted: a.m. 3-- 6 - a ��- Requester: Phone No: — / 3 -7027 INSPECTION RECORD Retain a copy with permit INSPECTION N . PERMIT NO. CITY OF .UKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Inspector Receipt No.: Dide-//6 Corrections required prior to approval. 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dater Date: - ..mot.. Proiex Li f�fl Type of�I Oec nI KJ 6 - A Address: Iy (on 5 35 S Date Called: c..) -ffe " Special Instructions: / Date Wanted: 7 I19) ite m. Requester: Phone No: 2 — J3I '' 1727 --� INSPECTION RECORD I ` Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector( 'Receipt No.: 3 0,4 'Date: Dv -r� PERMIT N 16 (206)431 -3670 Corrections required prior to approval. Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Mum Jr. Ack COMMENTS: _...- ---'"'-- Type of Inspection Ditlei i ie fi lG rq �St —; )^ AR A. ,D 1(J A- 4 1-)-F Lei' ,t co -L A - k .‘ It )1 i e - 1 e". Special Instructions: / Date Wanted: Q a-nr` Requester: Phone No: ye - _y6 3 - 702 f2 . Project: C‘-X(9r.- 3 52,. /niV---<°.4) 're' Type of Inspection . Address: / 1 /3 35" , 19 ti S Date Called:Q^ tt � f f ' J Special Instructions: / Date Wanted: Q a-nr` Requester: Phone No: ye - _y6 3 - 702 INSPECTIO NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter •Blvd., #100, Tukwila, WA 98188 • Approved per applicable codes. Receipt No.: INSPECTION RECORD Retain a copy with permit 1. Corrections required prior to approval. ctor: � Datei LI $60.00 REINSPECTION FEE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1Date: Project: Etepf. $5 /,'.i, Y ,1 c c „_ Type of Inspection: • Fri.. ,'n,, j Address: 9 1- 1 403 Suite #: A.r 4a. 59 Contact Person: Special Instructions: Phone No.: Needs Shift Ins•ection:.a Sprinklers: Fire Alarm: Hood & Duct: / Monitor: Pre -Fire: Permits: Occupancy Type: a.. • INSPECTION RECORD Retain a copy with permit • • INSPECTION NUMBER . PERMIT NUMBERS • I • CITY OF TUKWILA FIRE DEPARTMENT" • 444 Andover Park East:, Tukwila, Wa. 98188 206- 575 -4407 COMMENTS: R Approved per applicable codes. Inspector: Std. Word /Inspection Record Form.Doc 1/13/06 Corrections required prior to approval. Date: 3 JO 7 Hrs.: . $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance pepartment. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project Info Project Address / 4 6 ? 3r-at, AV s . Date For Building artpient•Use CITY OF TUI4,.W LA MAR 0 4 2008 PERMIT CENTER 1 er FL• Applicant Name: -t'f Ocy T�� Applicant Address: �� 0 0 /444, v s Applicant Phone: r \ ` . 7/ _/ /1 7 / Project Description / J Plaris Included requirements. • New Building • Addition X Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive % Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) . ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts ■ No changes are being made to the lighting • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft ** Area in ft2 Allowed x Area 1 er FL• 1 p,u NDVa/ woi K ,+4 r. °— w 3 2-4 / 32 i, 'i 1 / L- h- CoMb o / hi- ‘(— wa eK 4 2'x .' F - -Ua*r / 6 a:.ii1 APPR ' . ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts M Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Iz 14. wA-i.(, Mouvi7 Fix / 61' 61 i, 'i 1 / L- h- CoMb o / hi- ‘(— wa eK 4 2'x .' F - -Ua*r / 6 a:.ii1 APPR ' . M No Of k ila r 7 77,1P Total Proposed Watts may not exceed Total Allowed Watts s -nor Total Proposed Watts etc? w CITY OF TUKWILA - BUILDING DIVISION _ -2006 Wasington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. Use` LPA (W /sf) Use' LPA /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)'•'•" 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments', restaurants /bars' 1.3 Post office 1.1 Dormitory 1.0 Retail` ", retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia ', assembly spaces' 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference /exhibition hall'•" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers O Other Q ualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited byCode. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. CITY OF'TU'KWILA - BUILDING DIVISION 2006 Wasington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2008 Washington State Nonresidential Energy Code Compliance Forms -9 unit Lignting Power Allowance Revised July 2007 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling hei Ive.rett. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Alloviance -for ssernbly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. _ 7) For conference rooms and offices less than 150ft with full height partitions, a Unit LighfingfiowerAllowance of 1.10 wife may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the agks.!The height all fined 'n footnote 2 applies only to the floor area not covered by racks. �L l 1 r 07 -15 -2008 ANDY TEH 1009 9 AV S EDMONDS WA 98020 RE: Permit Application No. D08 -118 14603 35 AV S TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 03/04/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 08/31/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 08/31/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, °V J er Marshall Permit Technician xc: Permit File No. D08 -118 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 March 17, 2008 Andy Teh 1009 — 9` Avenue S Edmonds, WA 98020 RE: CORRECTION LETTER #1 Development Application Number D08 -118 Express Linen Service —14603 — 35 Avenue S Dear Mr. Teh, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building, Fire and Planning Departments. At this time the Public Works Department has no comments. Building Department: Allen Johannessen, at 206 - 433 -7163 if you have questions regarding the attached comments. Fire Department: Jack Waller, at 206 -575 -4407 if you have questions regarding the attached comments. Planning Department: Brandon Miles, at 206 - 431 -3684 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messener service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, uhfrak kive Brenda Holt Permit Coordinator encl City of Tukwila Department of Community Development Jack Pace, Director P:\Permit Center\Correction Letters \2008\D08 -118 Correction Ltr #1.DOC wer • • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 6 Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo • • Date: March 14, 2008 Project Name: Express Linen Sevice Permit #: D08 -118 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. A wheelchair accessible bathroom is shown with a lower level employee work area. However access to the bathroom and lower work areas are divided from other work areas by steps. An accessible route shall be provided to each portion of the building. This includes the common use circulation paths located within the employee work area with out having to travel outside of the building. One alternative would be to provide a ramp to the lower portions of the building which may be intrusive on the allowable work space. Otherwise another alternative would be to raise the floor even with the upper work areas where all floors are at the same level. Please revise plan to show compliance with accessible routes throughout the work space. ( IBC 1104.3 & 11004.3.1 EX. #3) 2. Regarding the handicap ramp, a curb or barrier shall be provided that prevents the passage of a 4 -inch diameter sphere where any portion of the sphere is within 4 inches of the floor. In addition ramps shall be minimum 36" clear width measured between handrails. Please show ramp curb or barrier on the plan. (ANSI 405.9.2 & 406.4) 3. In addition to item 2), landings off ramps where there is a change in direction shall be provided with a clear turning space of 60 inches. Please adjust the ramp or provide for the required turning space at the top of the ramp. (ANSI 304.3.1, 405.7 & Fig. 405.7) 4. General changes in floor surfaces, (to include entrance doorways) where there is a height change greater than 1/4 inch vertical the additional rise shall be beveled and not exceed a height of '/2 inch. Please provide a note or detail to show floor surface complies with accessibility. (ANSI 303.2 & 303.3) 5. Revise the accessible code reference indicated on the cover sheet (WAC 51 -40) to reference the current 2003 ICC /ANSI. 6. Please provide (4) complete sets of revised drawings. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. Project Name: Express Linen Service 1460335AvS Permit File No.: D08 -118 Date: Mar. 6,2008 Reviewer: Capt. Jack Waller Fire Prevention Officer (206)575 -4407 • • FIRE DEPARTMENT REVIEW COMMENTS 1. Provide more complete description of planned use and processes. 2. Provide a list of chemicals that will be used in the processes with MSDS's for same. r DATE: CONTACT: RE: ADDRESS: ZONING: STAFF: March 10, 2008 Andy Teh D08 -118 14603 35 Ave S RC Brandon Miles PLANNING DIVISION COMMENTS The Planning Division of DCD has reviewed the above permit application. The application as submitted cannot be approved. 1. The proposed ramp does not comply with setback requirements. The required front setback in the RC zone is 20 feet. The ramp, as proposed, will extend into the setback. The ramp will most likely have to be relocated to the rear of the property. Please be aware that the required setback from S. 146 Street is ten feet. ACTIVITY NUMBER: D08 -118 PROJECT NAME: EXPRESS LINEN SERVICE SITE ADDRESS: 14603 35 AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # DATE: 07 -07 -08 Response to Incomplete Letter # After Permit Issued DEPARTMENTS: g , � �'l � pv /.W(,1 -►D Buil in Islon ire Prevention U Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 11 1)ER9NIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete Structural Review Required Approved with Conditions u H DUE DATE: 07 -10 -08 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 08 -07 -08 Not Approved (attach comments) ❑ DATE: 114 ' Planning Division Permit Coordinator Not Applicable Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -118 DATE: 03 -05 -08 PROJECT NAME: EXPRESS LINEN SERVICE SITE ADDRESS: 14603 35 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: B scion Public Works D 1414A DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route TUES/THURS ROUTING: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents routing slip.doc 2 -28 -02 12( • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ' V-0g Fire Prevention Structural Incomplete Structural Review Required DATE: dtwia 3- tf5 Planning Division n Permit Coordinator n DUE DATE: 03-06-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: n No further Review Required DUE DATE: 04-03-08 Approved n Approved with Conditions n Not Approved (attach comments) {� Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 7' Ping PW ❑ Staff Initials:_ / p/''/ Date: of -0 - - ©6 Project Name: Project Address: Contact Person: • City of Tukwila \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.citukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: f> O — J / ❑ Response to Incomplete Letter # Response to Correction Letter # ( ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner 4 L I vle/J < -Kv A y 7 �� Phone Number: (4-2,0 77/— //52— Summary of Revision: ( • C A r P RA—MIt c47 o/✓ 2 . l _ e T�/Cgtf o Lib 3 , f9't2oj f47-- PECEuitb efTv of- vow <W l-A 1 JU'L 01 2 000 PERMIT CENTEP Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1 `-7—O8 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC SB0540 02/14/2002 Until Cancelled 01/01/1980 $12,000.00 02/20/2002 2 CBIC SB0540 07/11/199702/14 /2002 $6,000.00 1 CTOARINS SAl201879 07/09/1994 07/09/1997 $6,000.00 Name Role Effective Date Expiration Date LEE, KING 01/01/1980 WONG, KAI 01/01/1980 WOO, LILY 01/01/1980 WONG, AMY 01/01/1980 Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with L£tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. MONARCH TRADING CORP Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MONARCH TRADING CORP 2067636161 PO BOX 80563 SEATTLE WA 98108 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 600465574 ACTIVE MONARTC065Q1 CONSTRUCTION CONTRACTOR 11/21/1994 3/6/2009 GENERAL UNUSED Business Owner Information Bond Information Insurance Information Insurance Company I Policy I Effective I Expiration lCancellImpairedl Amount I Received Page 1 of 2 https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= MONARTC065Q 1 07/30/2008 ROOM FINISHING SCHEDULE EXTERIOR WALL (2X4 @16" O.C.) (EXISTING) EAST SOUTH WEST NORTH COVE- BASE CEILING , AREA WALLS FLOOR WORK AREA- N PAINT PAINT PAINT PAINT S.V. 6" RUBBER PAINT WORK AREA- S PAINT PAINT PAINT PAINT S.V. 6" RUBBER PAINT REST ROOM FRP FRP FRP FRP S.V. 6" RUBBER PAINT OFFICE/SIR. PAINT PAINT PAINT PAINT S.V. 4" RUBBER PAINT OR, 2X4 STUD @16 "O.C. ,O t � WALLS TO BE DEMOLISHED L NOTE: WALL PAINTING TO BE SEMI -GLOSS FRP AT ALL PLUMBING FIX. AREA & REST ROOMS ABBREVIATIONS S.V. = SHEET VINYL A.C.P. = ACOUSTICAL CEIL. PANEL LAM. = LAMINATED FRP = FIBER REINFORCED PANEL GWB = GIBSON WALL BOARD CABINET AND COUNTERS D. EQUIPMENT NUMBERS FINISH CONSTRUCTION SHELVES DOOR/DRAWER WORK COUNTER LAM. TOP, STAIN FRONT & BACK 3/4" PLY. CONST. OFFICE DEST LAM. TOP, STAIN FRONT & BACK 3/4" PLY. CONST. 2@ OPEN SHELVES NO DOOR, 1@ DRAWER 1@ OPEN SHELF NO DOOR, 1@ DRAWER LEGEND EXTERIOR WALL (2X4 @16" O.C.) (EXISTING) INTERIOR WALL (FL. TO CEIL.) ii (EXISTING) 2X4 STUD @16 "O.C. INTERIOR WALL (FL. TO CEIL.) �� :i :��are:EV. (NEVV) 2X4 STUD @16 "O.C. , . am 1� – BEAM / HEADER ABOVE ( C tin Inn• n �n � t . PONY WALL (4' H. MAX.) 20g. 3 -5/8" METAL STUDS @ 16" O.C. OR, 2X4 STUD @16 "O.C. ,O t � WALLS TO BE DEMOLISHED L I SHELVE FIXTURE UNDER ASME FULTON F -10 11 D. EQUIPMENT NUMBERS — `` N METAL FRAME, GLASS DOOR \ (EXISTING) 3- 6 S � r WOOD FRAME, SOLID DOOR (NEW OR EXIST.) 0 \ 3 - 6 - WITH LEVER TYPE HANDLES ON ALL DOORS \ ALL RESTROOM DOORS TO HAVE AUTO - CLOSER NOTE: POST SIGNS ON ALL EXIT DOORS STATING: 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" ALSO REFER TO IBC 1008.1.8 FOR HARDWARE REQUIREMENT # ,. .Q S t � k L1E5G IRTIOIV k: ,.. . _. ... A E.... K JM ,. OI=L lE X D X • . ( 4 1 - 4 ) RE�yUF �E , . am 1� . G ` ( C tin Inn• n �n � t . BUT A r require I r In ,O t � �1 s Rama -N rk# tit C• s• 1 1 43G Hot Water Heater AD Smith BTH199 28° D. XIS" H 120-60-1 6/15 3/4"? 1" 2 1 434 BLOWDOWN TANK ASME FULTON F -10 11" D. X32" H NIA N/A 2" 1" 3 1 433 STEAM BOILER FULTON FB -A 9.9 HP OR 8 HP 33 "X39 "7068" 120-60-1 5.2/15 399,000 BTU '1" NPT 6 of 4 1 435 Steam Condensate Returi with Pump VT10 18" D. X30" H 120-60-1 10.6/15 1" 1/2" 3/4" 5 2 439 Washer Washcomat - SU655CC 33 "X39 "756" 240 -60-1 7.6/15 2" Hot /Cold 3" Need 2 sets of H/C hose bib valves 6 1 441 Vacuum Spotting Board Sailstar SSB -20 49 "X20 "X41" 115 -60 -1 9 1/2" steam in & outlet, 1 -112 vacuum 7 2 440 Dryer Washcomat - TD75 WMC 38 "X54 "X90" 208 -60 -3 4.8/15 151,200 BTU 3/4 NPT 4" 2 cfm 8 1 437 Air'Vacuum REMA RP -5 19" D. X48" H 240 -60-1 11/20 2" 1/2" 9 1 43$ Air Compressor (5 hp) 80g tank Saylor -Beall B705 -5 Shp 33 "X22 "7030" 208 -60-3 13/20 1/2" 10 1 442 Ironer - Flat Press HUEBSCH /UNIMAC UD13F126 168 "X42 "746" 120 -60 -1 5.2/15 136,000 BTU 3/4" NPT 4" 2 cfm 11 1 444 Ironer - Head Press Sankosha AHP450U 55 "7039 "X49" 220 -60-1 0.14/15 12 2 443 Ironer - Legger Press Sankosha DP -155RU 75 "X41 "X61" 220 -60 -1 2.8/15 13 1 445 Water Chiller 5 Ton 5CP Chiller (optional) 14 1 24' 11' -10" 12' -2" L LAUNDRY EQUIPMENT LIST 9' -2" OFFICE (STORAGE) X r- 2 . 68 D. CD w n w J r 2' -6" (ROOF LINE) 5' -5" STORAGE MIN. 18" CO 0' M SCALE: 1/4"=1 Express Linen Service 4' x/111 DE CONC.WALKWAY. 9; :l BLOW- DOWN L��m?P .:' �..,�'�y w': �SS��' �7i�!'' �I-.°! �.. �' Y _ �_ _„a. „n• "�'j'_' EGGER PR SS 4' -0" 2' -O” HEAD PRESS DRYER SB 32" SINK OVEN 30" (PUSH -IN) IRONING WORK AREA 126" 51' -0" 16' -10" 36" J EMP. LUNCH RM. REF L`�J (EXIST. 5X12 BEAM ABOVE) Q N (EXIST. COL.) 163" FLAT PRESS UD20F126 51' -0" CONC. STEPS C AWL SPA ACCESS POST OCC. CAP. SIGN (6) ON THIS WALL (COVERED PORCH) l t7 (EXIST. 5X12 BEAM ABOVE) ELEV= +14-3/4" D ENTER POST ADDRESS \� (14603) i e', 14603 35th Ave 5, Tukwila, Wa 98168 RHEEM CLASSIC 90PW5 (EXIST) FURNA VENT TO ROOF COI STRAPPED TOP & BTM. Il WASHER 39 WASHER / 39 O m ca 3' MIN. ELE. O 18" 17' -0" (EXIST. 5X12 BEAM ABOVE) LAUNDRY WORK AREA 17' -D" DRYER 51 REST ROOM HDCP " 111 J (EXIST) \ \ \ 3- 6- /x. FLOOR PLAN (EXPRESS LINEN SERVICE) . 0 z. ) 1 (LANDING) 5X5' • 3 6 4 ' 0 " 4 -0" (MIN) 21' -8" Page -1 of 1 9CE COMPLIANC APPROVED JUL 18 250E City Of Tukwila BUILDING DIVI51OLL 1)0B ECEIVED JUL 072008 PERMIT CENTER PAGE: 2 LIGHT SWITCH SCHEDULE LEGEND 1 LIGHTING BUDGET ALLOWED LIGHTING BUDGET 1,326 watts ( 1,326 sf X 1.0 watt) SWITCH # AREA FIX. LEGEND DESCRIPTION WATTS PER FIX WATTAGE FAN -LIGHT COMBO. • FAN ONLY 65W/ 75 CFM 120 CFM PHONE LINE (ROUGH -IN ONLY) LI (RO UGH NE -IN ONLY) REST. RM ICY `*' WALL MOUNT LIGHT (NUMBER =TYPE OF FIXTURES) (INCHES = DISTANCE TO FLOOR) 65 1 @ 65 w FIRE SPRINKLER HEAD REST. RM �,� c F) FAN -LIGHT COMBO. 65 1 @ 65 w KITCHEN CEIL. RECESSED 3 TUBES FLUORESCENT LIGHT 43 16 @ 688 w � = ) PROPOSED LIGHTING BUDGET: 818 watts NOTE: LIGHTS SWITCHED AT DAY LIGHT ENERGY SAVING ZONE (15' FROM WINDOWS) TO BE SWITCHED SEPARATELY (FLOOR) SCALE: 1/4 " =1/2" E O 0 (EXIST. 5)12 BEAM ABOVE) IRONING WORK AREA 7 L, FRAMING PLAN SCALE: 1/4 " =1' -0" DOOR THRESHOLDS IBC 1008.1.6 1/4" (MAX) (FLOOR) (1/4" MAX) EMP. LUNCH RM. (EXIST. 5X12 BEAM ABOVE) UP (VENT) SPACER 2X10 FL. JOIST @12 "0.C. (EXIST. 5X12 BEAM ABOVE) LAUNDRY WORK AREA (VENT) 4X4 TREATED @4' O.C. SCALE: 3/8 " =1' -0" 17' -0" ON CONC. SLAB REMOVE EXIST. WINDOW INSTALL NEW DOOR 2X10 FL. JOIST @12 "O.C. ON CONC. SLAB (SEE DETAIL THIS PAGE) EXIST. SLAB ON GRADE 4 (VENT) (VENT) (3/4" CDX) FLOOR JOIST - SECTION VIEW 4' Lil ci z U V (LANDING) III \ 5' W 0 0 8 -4" 21' -8" 30' 24' 12' -2" L 2006 I1C 717,2.7 Concealed sleeper spaces wood sleepers are used for laying flo aces masonry or concrete fire - resistance floors g On the space between the floor slab and the underside of the wood flooring shall be material to filled with an a resist g of flame an the free passa a flame an d d products of combustion or manner that there will be fire - blocked in such a floorin e no open spaces under the such s g that will exceed 100 square feet in pace shall be filled solidl y under area and partitions so that there is no co under permanent the flooring between adjoining nimunication under g rooms, 9' -2" OFFICE\ (STORAGE) ` u? 1 17—= • I 120 CFM it ". 2' -6" 5' -5" (EXIST. COL) -- '• 1 11ZI 4' -O" SCALE: 1/4" =1' -0" iN: a L. I— L__ 51' -0" 16' -10" (EXIST. 5X12 BEAM ABOVE) 120 CFM IRONING WORK AREA r 51' -0" C - AWL SPA ACCESS EMP. LUNCH RM. x if ZJ (EXIST. 5X12 BEAM ABOVErtn 71 I t- i i L_ J a [t b_ 1 Io al En 01 z i • • i 4 � EXIT UP TO IRON. WORK AREA -C1} u p .,.. I up I', CEILING / LIGHTING PLAN 17' -0" 1T-0" T -O " REST ROOM tp. I LAUNDRY WORK AREA 1 PROVIDE RECEPTACLE (EXIST. 5X12 BEAM ABOVE) • 120 CFM ELE Le AT CEIL. HEIGHT FOR WINDOW SIGN 8 -4 " REVIEWED CODE COMPLIANCE APPRO VED JUL City of Tukwila BUILDING GDIVISION_ D08- 118 ECEIVED JUL 07 2006 PERMIT CENTER PAGE: 3 LEGEND [7. 2`X4' � LIGHT(S) TO BE REMOVED /DEMO. $ LIGHT SWITCH SWITCH W/ DIMMER $3 3 -WAY SWITCH L F FAN -LIGHT COMBO. • FAN ONLY 65W/ 75 CFM 120 CFM PHONE LINE (ROUGH -IN ONLY) LI (RO UGH NE -IN ONLY) ILLUMINATED EXIT SIGN AC /DC BACK-UP IExi'I' LEE a v EXIT LIGHT AC /DC BACK -UP G FIRE SPRINKLER HEAD Cr DOUBLE OUTLET (NUMBER =AFF) CE DP DEDICATED WALL OUTLET FOR DATA PROCESS DEVICE (FLOOR) SCALE: 1/4 " =1/2" E O 0 (EXIST. 5)12 BEAM ABOVE) IRONING WORK AREA 7 L, FRAMING PLAN SCALE: 1/4 " =1' -0" DOOR THRESHOLDS IBC 1008.1.6 1/4" (MAX) (FLOOR) (1/4" MAX) EMP. LUNCH RM. (EXIST. 5X12 BEAM ABOVE) UP (VENT) SPACER 2X10 FL. JOIST @12 "0.C. (EXIST. 5X12 BEAM ABOVE) LAUNDRY WORK AREA (VENT) 4X4 TREATED @4' O.C. SCALE: 3/8 " =1' -0" 17' -0" ON CONC. SLAB REMOVE EXIST. WINDOW INSTALL NEW DOOR 2X10 FL. JOIST @12 "O.C. ON CONC. SLAB (SEE DETAIL THIS PAGE) EXIST. SLAB ON GRADE 4 (VENT) (VENT) (3/4" CDX) FLOOR JOIST - SECTION VIEW 4' Lil ci z U V (LANDING) III \ 5' W 0 0 8 -4" 21' -8" 30' 24' 12' -2" L 2006 I1C 717,2.7 Concealed sleeper spaces wood sleepers are used for laying flo aces masonry or concrete fire - resistance floors g On the space between the floor slab and the underside of the wood flooring shall be material to filled with an a resist g of flame an the free passa a flame an d d products of combustion or manner that there will be fire - blocked in such a floorin e no open spaces under the such s g that will exceed 100 square feet in pace shall be filled solidl y under area and partitions so that there is no co under permanent the flooring between adjoining nimunication under g rooms, 9' -2" OFFICE\ (STORAGE) ` u? 1 17—= • I 120 CFM it ". 2' -6" 5' -5" (EXIST. COL) -- '• 1 11ZI 4' -O" SCALE: 1/4" =1' -0" iN: a L. I— L__ 51' -0" 16' -10" (EXIST. 5X12 BEAM ABOVE) 120 CFM IRONING WORK AREA r 51' -0" C - AWL SPA ACCESS EMP. LUNCH RM. x if ZJ (EXIST. 5X12 BEAM ABOVErtn 71 I t- i i L_ J a [t b_ 1 Io al En 01 z i • • i 4 � EXIT UP TO IRON. WORK AREA -C1} u p .,.. I up I', CEILING / LIGHTING PLAN 17' -0" 1T-0" T -O " REST ROOM tp. I LAUNDRY WORK AREA 1 PROVIDE RECEPTACLE (EXIST. 5X12 BEAM ABOVE) • 120 CFM ELE Le AT CEIL. HEIGHT FOR WINDOW SIGN 8 -4 " REVIEWED CODE COMPLIANCE APPRO VED JUL City of Tukwila BUILDING GDIVISION_ D08- 118 ECEIVED JUL 07 2006 PERMIT CENTER PAGE: 3 33" EXIST. GRADE 5' -0" (ROOF LINE) 8.5 ELEV= +14" REMOVE EXIST. WINDOW INSTALL NEW DOOR EXIST. VINYL SIDING ELEV = +14" NORTH ELEVATION / RAMP (ELEV= +14 -1/2 ") SCALE: 3/8 " =1-0" CURB TREATED 4X4 5' -0" 18'• -2" (5' LANDI 30' -0" EXIST. 2X8 RAFTER ELEV= +14" 30' ANCHOR FOR RAIL. @ 4' O.C. TYP RAMP - TOP VIEW SCALE: 3/8 " =1' -0" HANDRAIL (BUILDING) / CURB TREATED 4X4 — (CONC. RAMP SLOPE: 1:12) - 14' -0" EXIST. 5X12 BEAM , .- t : mow, =g- NEW 4» THICK (1:12 CONC LOPE) TOPPING G SLAB CURB 4X4 TREATED LOST FORM, OR, RIDGED ELEV =O GRAVEL BEDDING. STYROFOAM (4" OR 2" THICK) �- """ �. SPACE FILLER (UNDER 4" SLAB) TYP ELEV =0 (EXIST GRADE) ELEV =O 1 •! ELEV =O 4' -O" (WALKWAY) RIDGED STYROFOAM SPACE FILLER (UNDER) TYP CONC. 'RAMP L ___ SLAB ON GRADE AT NORTH OF BUILDING 4' -0" FLOOR JOIST AT SOUTH OF BUILDING ACCESSIBLE PARKING EXIST. GRADE (CRAWL SPACE AT S. OF BUILDING) V.A. 4 ► ! ��� Fr;. k41 4 (INT. FLOOR) (CONC. SLAB) (ACCESSIBLE PARKING) T.P. S/S GRAB BAR 1 -1/2" TYP. 18" 1_24" MIN VAPOR BARRIER 1 4" THICK CONC. TOPPING SLAB 60" MIN. (P -LAM OR FRP) WASHABLE WALL FINISH TYP. LATEX PAINT, SMOOTH FINISH J 5. TYP. INTERIOR WALL SCALE: 3/8 " =1' -0" WATER RELEASE ON OPEN SIDE 17 -19" 1 RAMP - SECTION VIEW SCALE: 3/4 "=1' -0" (AT HIGHEST POINT) 3 4 - iEM=iii- i M - UNDISTURBED - rfTT =1. SOIL 2X6 NAILER @24" O.C. (EXIST. CEIL.) TOP PLATE FIRE BLKS AT 8' 48" 2X4 STUDS 16" O.C. MAX. SCALE: 1/2" = 1' -O" TYP. REINF'G #4 at7•2 "O.C. EA. WAY (ROOF) (EXIST. ROOF RAFTER) FLOOR PLATE (TREATED 2X4 ON CONC. FL) FLOOR PLATE (2X4 ON WOOD FRAMED FL) ANCHORED W/ MIN. 3/8'X 2 -1/2" CONC. EXP. BOLT 24" D.C. ON CONC. FL) OR, 3/8"X 3 -1/2" LAG SCREW 24" O.C. ON WOOD FL) (SIDE) (FLOOR) 7 - 9" 1/2" CHAMFER GRAVEL BEDDING 59" �• MIN. ig- (56" MIN. IF WALL HUNG WATER CLOSET IS USED) (PARTITION IF APPLY) LAMINATED 39 "- 41" LEGLESS �� SHEET VINYL FLOOR COVERING 15" MIN. 6' -8" 0 TO 14 -1/2" (EXIST. GRADE) 6" (MIN.) ALL RESTROOM DOORS TO HAVE AUTO - CLOSER TYP. LEVER TYPE HANDLES ON ALL RESTROOM DOORS 38" REST ROOM DOOR AND DOOR SIGN MIN. -- 30" ---*- (LIGHT FIXTURES) (MIRROR) / LAVATOR� TEMP. SHIELDING TYP. CONTINUOUS VINYL COVE BASE, SEALED AT ALL CORNERS (DOOR) SOAP P.T. ---= / SINGLE ARM / FAUCET A BARRIER FREE RESTROOM DETAIL PIPE RAIL - DETAIL SCALE: 3/4"=1'41" 6" 28" 5-1/2" 7 • 6 ,5 -1/2' 60" 48" MIN MIRROR 4 "— MEN .. • " " SINGLE ARM FAUCET 2" TYP. 5 y2 TYP. 36" (34 " -38 ") 6' MIN. (Pictograms) In TEXT Tactile 3" charactors REVitwt s ADE COMPLIANCE APPROVED JUL 18 ?O City Of Tukwila BUILDING DIVISION (P - LAM OR FRP) WASHABLE WALL FINISH URINAL (IF APPLY) 17 MAX. 5' -0" MIN. ECEIVED JUL U7 B PERMIT WWI PAGE:4