HomeMy WebLinkAboutPermit D08-154 - PACIFIC POWER TECH - STORAGE RACKSPACIFIC POWER TECH 1120 ANDOVER PK E D08 -154 Parcel No.: 2623049098 Address: 1120 ANDOVER PK E TUKW Suite No: Tenant: Name: PACIFIC POWER TECH Address: 1120 ANDOVER PK E , TUKWILA WA Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST , RENTON WA 98057 Phone: 206 - 818 -4488 Contractor: Name: NORTHWEST HANDLING SYSTEMS Address: 1100 SW 7 ST , RENTON WA 98055 Phone: Contractor License No: NORTHHS963ND doc: IBC -10/06 Cityif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Owner: Name: LEUTHOLD DONALD W Address: 7275 W MERCER WAY , MERCER ISLAND WA 98040 Phone: Permit Number: D08 - 154 Issue Date: 05/21/2008 Permit Expires On: 11/17/2008 Value of Construction: $0.00 Fees Collected: $334.42 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: 0025 Expiration Date: 08/05/2008 DESCRIPTION OF WORK: ANCHOR EXISTING RACK AND SHELVING TO ADDRESS STOP WORK NOTIFICATIION RFA08 -015. * *continued on next page ** D08 -154 Printed: 05-21 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City (*Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Permit Number: D08 - 154 Issue Date: 05/21/2008 Permit Expires On: 11/17/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: Print Name: Date: J ') `U Date: S� 7/O, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D08 -154 Printed: 05-21 -2008 Parcel No.: 2623049098 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1120 ANDOVER PK E TUKW PACIFIIC POWER TECH 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -154 ISSUED 03/26/2008 05/21/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 11: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (IFC 2302) 12: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 13: Maintain minimum 6" longitudinal flue space between back -to -back racks. (NFPA 13- 12.3.1.14.1) doc: Cond -10/06 D08 -154 Printed: 05 -21 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us 14: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 13- 12.3.1.13) 15: Pallets shall be stored no higher than 6 feet (1.8 m). Each pallet pile of no more than four stacks shall be separated from other pallet piles by at least 8 feet (1.4 m) of clear space or 25 feet (7.6 m) of commodity. Idle wood pallets shall not be stored in racks. (NFPA 13- 12.1.9.1.2) 16: .Aisles in sprinklered buildings shall be a minimum of 44 inches (1118 mm) wide. Aisles shall be a minimum of 96 inches (2438 mm) wide in high -piled storage areas exceeding 2,500 square feet (232 ms) in area, that area accessible to the public and designated to contain high- hazard commodities. Aisles shall be a minimum of 96 inches (2438 mm) wide in areas accessible to the public where mechanical stocking methods are used. (IFC 2306.9.1.1) 17: The required aisle width shall extend from floor to ceiling. Rack structural supports and catwalks are allowed to cross aisles at a minimum height of 6 feet 8 inches (2032 mm) above the finished floor level, provided that such supports do not interfere with fire department hose stream trajectory. (IFC 2306.9.2) 18: Warehouses designed for high -piled stock shall establish and maintain aisleways of not less the 44 inches to provide access to all exits and fire department access doors. (IFC 2306.9.1.1) 19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 20: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 21: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 22: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 23: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 24: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 25: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder doc: Cond -10/06 D08 -154 Printed: 05-21 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 26: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 27: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and International Building Code. 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 31: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 32: These plans were reviewed by Marshal 51. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 33: These plans were reviewed by Chief 52. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 34: These plans were reviewed by Inspector 515. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 36: Please return the permit application with the appropriate fee within 30 days. Failure to return the permit application and the appropriate fee will result in an additional fee. 37: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 514. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** D08 -154 Printed: 05-21 -2008 Signature: Print Name: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. c_ c-(•Q.f/iec. --, Date: 5-6- 740' D08 -154 Printed: 05-21 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 help : ivww.ci.iukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 1 I dLO Al4over Suite Number: Tenant Name: ' � (1. T t . r -- 72c1-1 LL C New Tenant: Property Owners Name: pry r. l r) (, / / Mailing Address: 7 *75 �>J �AIP_�P �itJ�•v, i�Gf paw t /y, 6/4 ' ()'/Q City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: A t ke_ 56 (ef/r\ Mailing Address: (i 190 S-kd E -Mail Address: WI C c')('P.✓► Sol) 4) 4444 S- (O .'� GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: AJCw f t./J S G. l i fiJ Mailing Address: L �� ..� . kJ- S Contact Person: / e t lam' SCE reil.Sccs�i E -Mail Address: fro sore e t') Sol) 6,3 ifl An Contractor Registration Number: /t.)C)r 1 vl (e' i'i ,,c7, I t S t , .S /Y.ACr S RCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -GG ' .ress: Company Name: G CIL Mailing Address: `i 1-P- \A/ Contact Person: G E -Mail Address: Q:Wpplications\Porms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: .2.L,.,)- 30'1 6 Floor: ❑ Yes Day Telephone: Uzo6 02 tk/ /l City State Zip Fax Number: 1 1,d ac3- 69'/ (VCS; rdc- city Day Telephone: 9 6 " e t�1' Fax Number: 1( _ (lj ?(//t. / Expiration Date: ( ) l 1 1)M State Zip City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record �C3 . 5";12-14.06 v4 City State Day Telephone: �I r ! e 0 Fax Number: �l g " y Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ r J i cc) Existing Building Valuation: $ Scope of Work (please provide detailed information): AI G k ' -�-e" iS ii, e.--. ( y>'t, / ;S /v✓ Gddr- S y i -7 , <'t/ el /e. / F O2 --O/ c: p l426I o, 2..� er - tf - c ejy.c..,/ j.re j „ . rz.. A (2 J 1,..at. t' , — l i " C���,/Q: 4}7` i - si ! v I y /rack- sL►�t, , T / rW7lr`c, -) -� , / ix oict n i is afo-�/ l s f , . --.) du C.7 CIAS C.rr, '/i, -,. .' Will there be new rack storage? ❑ Yes o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes (No If "yes ", explain: FIRE PRO ECTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None e Other (specify) /'t KCi.eUt' Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x II" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: Applications'Forms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l Floor I ce )0 '; 000 ------, - 7,' /f y llivu 2nd Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck i BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ r J i cc) Existing Building Valuation: $ Scope of Work (please provide detailed information): AI G k ' -�-e" iS ii, e.--. ( y>'t, / ;S /v✓ Gddr- S y i -7 , <'t/ el /e. / F O2 --O/ c: p l426I o, 2..� er - tf - c ejy.c..,/ j.re j „ . rz.. A (2 J 1,..at. t' , — l i " C���,/Q: 4}7` i - si ! v I y /rack- sL►�t, , T / rW7lr`c, -) -� , / ix oict n i is afo-�/ l s f , . --.) du C.7 CIAS C.rr, '/i, -,. .' Will there be new rack storage? ❑ Yes o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes (No If "yes ", explain: FIRE PRO ECTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None e Other (specify) /'t KCi.eUt' Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x II" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: Applications'Forms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 BUILDING OWNER OR AUTHORIZED AFENT: Signature: Print Name: �i Thore ,.. Mailing Address: 1/ 0 J -S (4/ 7 S T Date Application Accepted: Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: _S / / Day Telephone: ?`06 /e 'c 2 e n'n t4 9)3 City State Zip Date Application Expires: 946 . 06 Staff Initials: Page 6 of 6 Parcel No.: 2623049098 Address: 1120 ANDOVER PK E TUKW Suite No: Applicant: PACIFIC POWER TECH Receipt No.: R08 -00906 Initials: WER User ID: 1655 Payee: MIKE SORENSON TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7089 334.42 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Total: $334.42 Permit Number: D08 -154 Status: PENDING Applied Date: 03/26/2008 Issue Date: Payment Amount: $334.42 Payment Date: 03/26/2008 10:17 AM Balance: $0.00 249.00 80.92 4.50 0430 03/26 9711 TOTAL 334.42 doc: Receipt -06 Printed: 03 -26 -2008 COMMENTS: e !Pik Type of Inspection: ct lJA( (.., dL )( Address: 11 2_0 P) P Pe e_ p eJJJui X- P . * ,f ;n • i n 5 C. -(1 ` ill' r , .r-P or I S!'tom ,t... A o .i e () >S> A-� l.. A . ..) 4 J` 4 . AA) G_ 'M(( e' f At .Q/f / ( i,J A 0 7. Projec P Ae lc lc e !Pik Type of Inspection: ct lJA( Address: 11 2_0 P) P Pe e_ Date Called: Special Instructions: ./"." Date Wanted: 7 - - so- ce fn p.m. Requester: Phone No: P-06- C IZ 14 r INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION VP-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. . nspect bo -rs�( Date? 0 �J n $60.00 REINSPECTION FEE REQU ' ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: pix. t _ Power -7 J( Type of Inspection: Sprinklers: - - -- - - - - -- - -- - - - -- - - - - -- Fire Alarm: ` Address: //W We Suite #: Contact Person: Omv 4 5 Special Instructions: .. Phone No.: /• 5P3 _ q 71 -- /Silo Needs Shift Inspection: _ _ S Sprinklers: - - -- - - - - -- - -- - - - -- - - - - -- Fire Alarm: ` ``Rood & & Duct: Monitor: P Pre - Fire: ' Permits: O Occupancy Type: • .e 54'F+"*'•:s`s k<' cs.. ; rss":. r.w�?GiMv <.c?..�. -E ...76»c�isv . . - — E. 9V41 ks:: i1+ IR.' iLL €.^;' ;x$+ESY- 'C+S.fK. %s:Yrn`G"G '!N+t'M'x'iFa.w4:+- - xsM:..n J INSPECTION NUMBER Approved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT e City of Tukwila Finance Department. Call to schedule a reinspection. 1/13/06 D or - IS PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 - 206- 575 -4407 • I I Corrections required prior to approval. COMMENT'Sf r . y , � a ;•' r Inspector: Date: Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from T.F.D. Form F.P. 113 RE COVeD se) 10 2 006 1)Lti al-D9 , 11 A.A.R. 'Testitig�Lalioi gory, Inc d7;1 ° 26S1 r 80h19A ",ve�N�E'�Pa k 1.80Suite`C101RedmondVVA'98052 • �^ • , 9 :,, : : ,.; - sP�tone� ,425`881 {58 5441, �, _, �,: �_; • `' _ Client: North West Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055 Contact: Mike Sorenson Date: 7/29/2008 Distribution: Field Report Time: Arrived on site to perform inspection of proprietary anchors, in accordance with project plans and specifications. Inspections were performed on new and existing pallet racks, and shelving units. Inspections were in accordance with rack drawing details; 3/ Pg 1of2, 3/ Pg 2of2, 5/ Pg 2of2, and ESR -1917. The following were inspected /verified and found in conformance: 1. Verified use of Hilti Kwik -Bolt TZ expansion anchors as specified. 2. Verified minimum embedment was maintained after final tightening for, 3 1/2 inches for the 1/2 bolts (detail 3/ Pg1of2) type A rack, 2 1/2 inches (detail 5/ Pg2of2) type c shelves, and 2 inches (detail 3/ Pg2of2) EZ shelves. 3. Performed torque wrench verification of installation torque on the anchors, as per ESR -1917. Verified torque of bolts to meet 40 ft/Ibs for the 3/8 bolts, and 25 ft/Ibs for the 1/2 bolts. Work inspected was found to be in conformance. �d Distribute Client I Distribute Contractor Distribute Engineer Distribute Owner Distribute Municipality [ Distribute Other Distribute Architect [ Distribute Other Report Number: 1156 Project Number: 08 -244 Permit #: D08 -154 Project Name: Pacific Power Tech Address: 1120 Andover Park E Temperature: Inspector: Ramos, Stephen ID #SI 012 Reviewed by: Kim Anderson All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden NORTHWEST he Material Handling Experts SITE ADDRESS: 1120 Andover Pk. E. TENANT NAME: Pacific Power Tech, LLC DATE: March 21, 2008 APPLICANT: Mike Sorenson / (206) 818 -4488 3. Stamped engineering calculations attached. 8. Building egress and exits indicated on attached drawings. 1)O8 IS'-I FILE COPY 11.na 1100 Renton, WA 98057 (425) 255 -0500 ph (425) 228 -6946 fax ATTENTION FIRE AND BUILDING DEPARTMENTS RACK /SHELVING INFORMATION SUPPLEMENT REVIEWED FOR CODE COMPLIANCE i Of Tukwila B LDING DIVISION 1. Load application and rack /shelving configuration drawings attached. ROVE MAY 1 6 2008 2. Attached plans detail the rack /shelving locations, dimensions, and specifications. Attached plans detail the building /ceiling configuration. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored: Industrial hydraulic and pneumatic components. Steel, cast steel, rubber seals, valves, pumps, fittings (copper, brass, etc...). Stored in wood boxes on wood pallets and in small open top cardboard boxes directly on shelves. 6. Sprinkler System Information: Dry system. 155 psi static pressure, 140 psi residual pressure. 7. Smoke and heat vents: In place, but not required for rack /shelving area square footage (3,000 sq. ft.). RECEIVED MAR 2 6 2008 PERMIT CENTER BY G. GHANIAN DATE. 3 -20 -08 SUBJECT STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: PACIFIC POWERTECH, LLC 1120 ANDOVERE PARK EAST TUKWILA, WA. 98188 PER IBC 2006 EDITION STORAGE RACKS CAPACITY: 3500 # / LEVEL AT TYPE "A" 200 # / LEVEL AT TYPES "B" & "C" CALCS. 1 THRU 8 DRAWINGS: RD -13123 RAdK DEOI(N & EN(4INEERIN(d dO. 412 WET BROADWAY, SUITE #204 LENDALE. dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 FILE COPY EXPIRES 12 -26 -09 SHEET NO. 1 JOB NO.. RD -13123 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 6 2008 RECEIVED MAR 2 6 2008 PERMIT CENTER BY G. OHANIAN RAdK DEON & EN(WINEERIN(4 CO. DATE. 3 -20 -08 SUBJECT. M N BEAM M= 106 "x1.9 = 25 °K 8 S — R 33 "K .75<.92 3 — A 384xI xE '41 "< 180 = 59" SEISMIC DESIGN S pS xl V _ R X 1 .4 WORKING STRESS r i 4. 4. S 1 1 =1 R =6 MOM. CONN. R =4 BRACED S =.95 W =D.L.+ 3 L.L. LOAD PER COLUMN L.L.= 2 x 5x3.5K =5.8K 3 2 cm. W=.2 +5.8 6K L.L. V = .95x1 x6 = 1 K TRANS. 4X 1 .4 106" FRONT VIEW IBC 2006 ASCE 7 (SEC. 15.5.3) V .95x1 x6 68 LONGIT. 6x1.4 412 WET BROADWAY, SUITE #204 C LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 44" 44" 1' 3500 #/ LEVEL +25% IMPACT LOAD 1900 #/ BEAM I =2.19 S =.92 F Y =55 KSI. LONGIT. SEISMIC .68 K 1 7K 09 K SIDE VIEW 13K 4K 9 K 11 .24 K . 4 "K 4 "K 10K 04 K 10 - 1 1 "K 44" 4 , / SHEET NO. 2 JOB NO.. RD -13123 VI G. OHANIAN RAdK DEOICiN & EN(INEERIN(I d0. DATE 3 -20 -08 412 WEOT BROADWAY, QUITE #204 ( LENDALE, dA. 91204 SUBJECT. TEL:(818)240 -3810 FAX:(818)240 -3813 COLUMN ANALYSIS In X- 3" t =.09" n COMBINED STRESS RATIO P M 6 11 P a + M ax = 20 +26 = . <1.33 Fy =55 KSI A =.8 S =.8 r =1.2 r =1 BASE PLATE ANCH. TENSION = 11—(6x3") = 0 ANCHOR SHEAR = fi =.34 K (2) -1/2 "O HILTI KWIK BOLT —TZ ESR -1917 OR APPROVED EQUAL. ALLOW. TENSION =.9 K ALLOW. SHEAR =1.5 K P 5/3 V 5 / 3 0 ) 5 / 3 (P a ) +(V) ( .9 ) +( 15 ) _ .08 <1.33 MOMENT AT BEAM CONNECTION 7/16 "0 RIVET A = .1 Fy = 79 KSI Va = .1x79x.4 3 Ma = 3 Kx4 "x1.33 = 16" K 3 PIN CONN. CONN. KI _ 32x1 .7 rx — 1.2 = 45 KI _�4_4_{ =40 Y Max = Sx.Fb =26 "K 10.5 "K 2 Fe = K x " = 141 r F F f =49 e P =F„ xA= 39 K Pa _ Pn 20 — 1.92 — _ SHEET NO 3 . RD -13123 JOB NO. KSI 7 3/4 "x5 "x3/8" BASE PLATE BYE G. OHANIAN RAdK DEOI(N & EN(INEERIN( d0. DATE . 3 -20 -08 SUBJECT OVERTURNING TOP LEVEL LOADING Kx2x160 "x.5x1.15 =184 "K MOT 64 " K M 1 M = 6 =264 "K MR =1.5 Kx44"= 66 " K NO UPLIFT LOAD TO DIAGONAL P 1 =2.3 F =55 KSI A =.31 r =.48 Q =.74 L= 52" CHECK WELDS F 12.3 KSI P = 3.8 K 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K CHECK SLAB 6000 _ 6 a' 1000 864 =29" 6x144=864 x 144 =864 °" M= (12 ) x1000x 2 x12 =2344 S= 12x6 = 72 6 2344 = 32 <1.6 ✓2500 =80 72 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 BOTH SIDES TYP. t =.07" 6000 # 6.5" 7.5" SHEET N0. 4 JOB NO.. RD -13123 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL BY G. OHANIAN RAdK DEOIdN Sc ENdINEERINd d0. DATE 3 -20 -08 SUBJECT. ICS N 0 in r DOUBLE RIVET BEAM 1, 3/32" 60" TYPE "B" LOAD PER COLUMN L.L.= 13x.2 K =1.3K 2 COL. W =.1 +1.3 =1.4K D.L. L.L. V= .95x1x1.4 =.15K 6x1.4 COLUMN ANALYSIS 1/4 't I x =.215 S =.13 F Y=36 KSI. t =.075" x —. —. —.— x I I 3 5/8" t COMBINED STRESS RATIO P• M 5.6 + 2.6 = . <1.33 a 412 WET BROADWAY, SUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 T 36" SIDE VIEW 200 # / LEVEL 100 # / BEAM M= 60 "x K = .75"K 8 S R 22 K = •03 <.13 M = .15 " =. 8K COL. 2 F =36 A =.40 S rmin =• Q =.75 K) 11 =17 r .64 Fa= 14 KSI P F =5.6 M =SxFb = 2.6 SHEET NO. 5 JOB N0. RD -13123 BY G. OHANIAN RAdK DEOI6N & ENdINEERIN( do. DATE 3 -20 -08 412 WET BROADWAY, {QUITE #204 LENDALE, dA. 91204 SUBJECT TEL:(818)240 -3810 FAX:(818)240 -3813 OVERTURNING = .15 "x.5x1.15 =26 "K M MR = 1.4 K x36 "= 50 "K NO UPLIFT BASE PLATE T= 0 ANCHOR SHEAR = .15 K (1) -3/8 "0 ANCHOR HILTI KWIK BOLT —TZ ESR -1917 OR APPROVED EQUAL. 2" EMB. MOMENT AT BEAM CONNECTION M — .8+ . 78 =. 79"K CONN. 2 V R IVET .252x3.14 x80x.4 =1.5 Ma = 1.5 .5 " x1 .33 =3.0 "K CONN CHECK SLAB 1400 = 1.4 °' 1000 /202 =14" M= ( ;'2) 2 x1000x z x12 = 260 "# s= 12x6 = 72 6 1.4x144=202 °" 260 = 3.6 < 1 .6 V' 2500 =80 72 .25 "0 RIVET F =80 KSI Y 0 0 0 0 I J L 0 0 1400# SHEET NO. 6 JOB NO. RD -13123 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL BY G. OHANIAN RAdK DEOI 4N & EN flNEERINc do. DATE . 3 - 20 - 08 412 WET BROADWAY. filUITE #204 SUBJECT LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 -H 48" TYPE "C" LOAD PER COLUMN L.L.= 2 x 8x.2K =.53 K 3 2 coL. W =.1 +53 =.63 K D.L LL. COLUMN ANALYSIS x F Y = 36 KSI A =.36 S . =.12 min. r . =.43 min. t= 0.105" COMBINED STRESS RATIO Pa Max = .63 +26= .28 <1.33 a LONGIT. SEISMIC K1 14 =33 r .43 F0=19.7 Ksi P =F xA = 7 K Max =Sx.Fb = 2.6 "K 18" 1 SIDE VIEW .07 K 0 SHEET NO 7 JOB NO. RD -13123 BY G. OHANIAN DATE. 3-20--08 SUBJECT OVERTURNING M OT = . 07 Kx2x120 "x.5x1.15 = 9.6"K M = .63 "= 11.3 "K NO UPLIFT BASE PLATE T =0 ANCHOR SHEAR = .07K (1) -3/8 "0 ANCHOR HILTI KWIK BOLT —TZ ESR -1917, 2 1/2" EMB. MOMENT AT BEAM CONNECTION M CONIC- = .5 +.45 2 = .48 "K M 36x.4x.09x.32x2 "x1.33 =1.1 "K RAdK DEOI(• Sc EN(INEERIN( do. 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(618)240 -3810 FAX:(818)240 -3813 N ,9 K 5/16" SHEET NO. 8 JOB NO. RD -13123 2 1/4"x2 1/2 "x1/8" BASE PLATE t= 0.09" (13 GA.) F Y= 36 Ksi ACTIVITY NUMBER: D08 -154 DATE: 03 -26 -08 PROJECT NAME: PACIFIC POWER TECH SITE ADDRESS: 1120 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DE ART ENTS: 6 g 1 ision Public Works n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 61L-1 ilvv(J Fire Prevention Structural Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved U Approved with Conditions Notation: REVIEWER'S INITIALS: u 2O$ DATE: DATE: Planning Division ❑ Permit Coordinator DUE DATE: 04 -01 -08 Not Applicable No further Review Required Not Approved (attach comments) n DUE DATE: 04 -29 -08 n L4 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Look Up a Contractor, Elect i n or Plumber License Detail Washington State Department of Labor and Industries License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License NORTHHS963ND NORTHWEST HANDLING SYSTEMS ELEVATOR CONTRACTOR CORPORATION RENTON KING WA 98055 ACTIVE UNUSED UNUSED 8/4/2004 8/8/2008 NORTHWH275JF ZINK *L *96603 Elevator Primary Contact Information License Name Status ZINK *L *96603 ZINK, LARRY ACTIVE • Page 1 of 1 https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= NORTHHS963ND 05/21/2008 C� 0 00 cn o P m 0) O Pro Co v L: O c:2 no614 7 o vZ ,�®, ®ate (') eIDSS3eldND0 �1Id !131)1NC dS TYPE - A TYPE - B TYPE - B TYPE - A TYPE - TYPE - C TYPE - TYPE - B 1 P1 El T TYPE - B SCALE PE - ' 1 1 1 -1 — TYPE - A N) Da dk1V?I -- -- -- -- -'qM1 - -La �■_ -- m x DNI )13Da DNI13A31 >130a TYPE - A H r r WINIy3�3 r SHEET DESCRIPTION RACKING PERMIT SCALE AS SHOWN REVISIONS DATE 3/24/08 DRAWN BY KEITH WERNER N0RTHWEsT .H' ° "�I`.I'N D L'. N .G S .Y:` S: <',;; 'I hi . ' ��4Su .1u 'JU.. '• f�:� . �G.1`a:S j 7 1100 SW 7TH STREET RENTON WA 98055 (425) 255 -0500 ANCHORAGE PORTLAND SPOKANE EUGENE YAKIMA PRO,. ECT TITLE PACIFIC OWERTECH, LLC PORTLAND - EUGENE - TUKWILA - SPOKANE NO PUBLISHED. ALL RIGHTS RESERVED. THESE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, AND ARRANGEMENTS THEREBY ARE AND SHALL REMAIN THE PROPERTY OF NWHS. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISCLOSED OR DISTRIBUTED TO OTHERS, SOLD PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF NORTHWEST HANDLING SYSTEMS. EXPIRES 12-26-09 ,.,-..,.., , ., .. 1 3/4", . --1—V\—T TYP 10 01 1001 N '''--.. 31 /0 1 f o-- P5 10 ..-- --- . 001' f5 o gl T{P• • 0 0 0 . .,:fiC4 kvo 'of) ,../ $ 1" ? o 0 , ... --.. --- V 1 t tr , v V A-- VI- Of CJ ri _v. 0 (111 ... .-... . I . _. ,- 0 • .-alf 01' .lif T 1--J ..-\ \ 2N - c .,9/9 11 c \ \ \ \, \C 0 1 0 7 I —I I - 0 \ 1 BOTH SIDES TYP> /8 1 /1 .5" r-,,,,. t=0.07" , , 1 1/2" A - IF 1--. 2 3/4" ''' „,.. 1/4"0 SAFETY LOCK (1000 # CAPACITY) ( 11 I ' c., -,.. 1 8 • _,......4 t..or .Aie SEC. A—A 0 2 \ ro r- 1 . 1 --.. N \ ( TYP 1/8 • 1 I i=.09" 1 Lo + • tO • • ,:. • 4 • . . ■ ' •:-:. Hi.. . • . . ' s . .....,.... • .- • ... • 11 . A. 1 I.. ',, • . - kl ro TYP 1 8 •1.8. I / J uL . . I * 1 N 4, . . .. . •4 , ... • .. 1 EMI \CC' i 1 1 \ s" t-----3/8" \ s I 1 7 J h1 z 9 V v 7 3/4" r i SEC. B—B / (2)-1/2"0 ANCHOR BOLTS PER BASE PLATE 3 1/2" EMB., (SEE NOTE 7/16"93 RIVET ASTM A576-90B t=3/16" BRACING DETAIL BEAM CONNECTION BASE PLATE DETAIL 3 ROW SPACER • • I. . k k k _ grab • 1 GENERAL CONFIGURATION 106" 44" 44" ' 44" NOTES: 1-DESIGN OF STEEL STORAGE AND CALCULATIONS OF THE IBC 2006 2-STEEL FOR ALL SHAPES 3-ALL WELDED CONSTRUCTION (E70XX ELECTRODES) 4-ALL ANCHORS HILTI 5-CONCRETE SLAB 6" 6-STORAGE RACK CAPACITY 7-ALL RACK INSTALLATIONS A , PERMANENT PLAQUE SHOWING THE MAXIMUM 8-STORAGE RACKS SHALL VERTICAL OF 1/2" RACKS AS SHOWN BY THESE DRAWINGS ARE IN COMPLIANCE WITH THE REQUIREMENTS EDITION FY=55 KSI. ASTM A607-85 GR.55 (EXCEPT AS NOTED) IN A SHOP OF AN APPROVED FABRICATOR KWIK BOLT-TZ (ESR-1917) OR APPROVED EQUAL. THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 3500 #/LEVEL TYPE "A" SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS EACH NOT LESS THAN 50 SQUARE INCHES IN AREA PERMISSIBLE UNIT LOAD OF 3500 #/ LEVEL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE IN 10'-0" OF HEIGHT RECEIVED MAR 2 6 2008 PERMIT CENTER ,t, 1 1, f I I ._.------------t - ED FOR - N cn , Co\ \ 13 \ 3 I REVLO puNNCE CODE C°t4 APPR ED E 2CIR 0 A ---------- • so _..--: ------ * i 1 OW VI DVISI°" - ,----- '.4- r . .4- -4 2,4- ,4- 1 _ \ ."! IN NI r .d- 1 \ It '? i iN to r -;i- .t C.1 In \ II ', , I , -4- -4- o co It \ / / '-4- -4- A IN rd) 2cv rn ' 11,---- REV. DATE REVISION If td- .4- . i I I \ --‘1( OH , .etil ; ISE 7,. RACK DESIGN AND ENGINEERING CA 912 4 412 WEST BROADWAY, SUITE #204, GLENDALE E \ — SCALE: NONE DRA ,4.K i DATE: 3-20-08 ' $ 7c. ... . .. 7' . S --1 , . 17. 41*335s-i52 4,,, ° c/ IP/ \ c., PROJECT: PACIFIC POWERTECH, LLC 1120 ANDOVER PARK EAST, TUKWILA, WA. 98188 JOB D-13123 NO. R SHEET NO. 1 OF 2 TYPE '' A " SIDE VIEW , -. 1 -4- ORAGE RACK DETAILS EXPIRES 12-26-09 EXPIRES 12 1/4" 1/4" GAP � % � 6). 0 �J .. ..... FP iG 3/32 1 . _,..„*.________.------- .) 1 11 I 1 / GA f0 I I 1 I ) 1 G �� ° 0 1 1 I w T IE 0 I 60 » 36 j 11/16" 1 11/16" t f W /TIE PLATE t cD Lo N 1 I I I L — n 1 I1 ..)--- I C n - a - J 3 5/8 O a 0 PLATE SEE DET.� 2.86" } � �.� rn O I O } U n 1 11 1 II I U 1. n U / / 41-11') `r � 11, r ......, _ � 11 J I I / �((((� / / /,� I i V K 9/ �I! / I` � � 5 M • 4 __ . , .. ii 1' a • P ' `N 0 jO f` �� '0 o n �C , e 4 e ° . a: d :: ° e G tl a ' ' 4 .. .q a c a 4 • . ae• e . ed • d , �: ° . • • , ' ,a /G z N I } Y" - II 1 /4"0 RIVET VII _ . I r _ N I L ,} \/y111�/�.- \/'-11'�•�_J} -._ I 1 } \ DOUBLE COL. B.PL. SINGLE COL. B.PL. } 3 4:1 + 110 14 GA. 14 GA. 1 -3/$ » 0 ANCHOR BOLT 1 -3/$ "0 ANCHOR BOLT 2 1/2" EMB. (SEE NOTE NO. 3) 2 1/2" EMB. (SEE NOTE NO. 3) 1/4"0 RIVET ASTM A345 -79 "TP" TIE PLATE ,•., .' + , . .• ' 4 _ • A ' • SHELVING COLUMN 1 DOUBLE RIVET BEAM 2, BASE PLATE DETAIL 3 TYPE "B" SIDE VIEW 4 °J)1 [ 11 [1 F:1 ii M NOTE NO. . t= 0.12" Oc 3) ')1 1 /2, -') 1 I il t 44 %.,.,,, F . TH'K +' `' CC_ c J ...---" =0.09 I I o.sa 7 z � , . 4 48" 18" [I a a ( ..."\,,,,„,. � I r POST 1.e7 I PC CONN. LOCKING PIN I, 1 TH'K =0.07 / 2ti °0 ■ r 0 t= 0.105 i / � / II [ I POST LOCKING PIN " WB " BEAM - + ./ i • “OZ L s I to N. Imwi � 0 1 3/8" 18 COLUMN 4111111111 1 - 3/8 " 0 ANCHOR' 2 1 /2" EMB. (SEE BOLT - _ � N 1111111111 • N N. , iV , _ r 0 N BASE PLATE DETAIL 5� "PC" CONNECTOR ( "WB" FRAME CONNECTOR (7 TYPE "C" SIDE VIEW (8J ._ ti::: ::k_ -. .' _ .''• __ :, I_�... - ti t NOTES: 1— DESIGN OF STEEL STORAGE SHELVING AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2006 EDITION 2 —STEEL FOR ALL SHAPES FY =36 KSI. ASTM A607-85 GR.36 (EXCEPT AS NOTED) 3 —ALL ANCHORS HILTI KWIK BOLT —TZ (ESR -1917) OR APPROVED EQUAL 4— CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 5— STORAGE SHELVING CAPACITY 200 #/ LEVEL 6—ALL SHELVING INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD OF 200 #/ LEVEL 7— STORAGE SHELVING SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 1O' -0" OF HEIGHT REVIEWED FOR i CODE COMPLIANCE , AP O E tl MAY l F 2008 City Of Tukwila EUILDING REC - ' air MAR 2 6 cuud PERMIT CEN I L. L REV. DATE REVISION 0 �- , o� w °1-1-447 r , 4 AZ RACK DESIGN AND ENGINEERING 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 SCALE: NONE DRAWN BY: ...AJCJJ. � . , ".. DATE: 3-21-08 ) 4 3 5552 � 4. cr k , PROJECT: PACIFIC POWERTECH, LLC 1120 ANDOVER PARK EAST, TUKWILA, WA. 98188 i ' ORAGE RACK DETAILS JOB N0. RD -13123 SHEET NO. 2 OF 2 EXPIRES 12